1.0
INTRODUCTION
1.1 General
This design note pertains to the design of foundation, columns, beams and floor slabs of
RUWI ROWER FOR M/s Zubair
The frame analysis has been done by computer software STAAD pro 2005.
Design calculation has been carried out in line with the design criteria attached herewith
2.0
Foundations
The foundation of the buildings are assumed safe bearing capacity of 250 KN/m2 at 3 m
below the finished ground level or as per the soil investigation reports
The soil report indicates that chloride contents are less than the permissible limits and
therefore, be applied to concrete surface in contact with soil and 3 coats of bituminous
paint is recommended for all block work in contact with soil.
3.0
Material
3.1
3.2
3.3
3.4
3.5
3.5
3.6
Grade of Concrete
Steel Reinforcement
Density of P.C.C
Density of R.C.C
Light weight concrete
Density of Hollow Block Work
Density of Solid Block Work
: M35
: 460 N/mm2
: 22 KN/m3
: 25 KN/m3
: 19 KN/m3
: 14.6 KN/m3
: 22 KN/m3
Ruwi tower
Page 1 of 5
4.0
4.1
4.2
Wall Loads
= 6.6 kn/m2
= (0.02x3.1x22) x 2
= 2.73 kn/m
4.3
4.4
5.0
= 0.3 t/m2
= 2.5 kn/m2
= 10.0 kn/m2
(locally applied load)
Live Loads
5.1
Accomodation area
= 2.0 kn/m2
5.2
Corridor / Hall
= 4.0 kn/m2
5.3
Roof
= 1.5 kn/m2
5.4
PARKING AREA
=5.0 Kn/m2
Ruwi tower
Page 3 of 5
6.0
WIND LOADS
Wind speed = 46m/s
7.0
SEISMIC LOADS
Seismic design for ZONE A (UBC CODE)
8.0
Description
DL
IDL (WALL +FINISHES)
LL
WLX
WLZ
EQX
EQZ
DL+IDL+LL
1.4DL+1.4IDL+1.6LL
1.4 DL+ 1.4IDL+1.4 WLX
1.4 DL+1.4IDL+ 1.4 WLZ
1.4 DL+1.4IDL+ 1.4 EQX
1.4 DL+1.4IDL+ 1.4 EQZ
1.0 DL+1.0IDL + 1.4 WLX
1.0 DL + 1.0IDL+1.4 WLZ
1.0 DL +1.0IDL+ 1.4 EQX
1.0 DL +1.0IDL+ 1.4 EQZ
1.2 DL+1.2IDL+1.2 LL+1.2 WLX
1.2 DL +1.2IDL+ 1.2 LL + 1.2 WLZ
1.2 DL +1.2IDL+ 0.5*1.2 LL + 1.2 EQX
1.2 DL+1.2IDL + 0.5*1.2 LL + 1.2 EQZ
DL=Dead load
IDL=Imposed Dead load
LL= Live load
WLX=Wind load in X direction
WLZ=Wind load in Z direction
EQX=Earthquake Load in X direction
EQZ=Earthquake Load in Z direction
Ruwi tower
Page 4 of 5
9.0
CONCRETE COVER
The concrete cover provided to the steel reinforcement in the design as below:
Locations
1. Face in contact with soil
2. Face away from the soil
2. Beam /column/walls
3. Slabs
10.0
11.0
ALLOWABLE SETTLEMENT
10.1 Total Settlement
10.2 Max Lateral Displacement
10.3 Differential settlement
Concrete Cover
75mm
50 mm
50 mm
30mm
= 25mm
= 25mm
=0.1% of lateral spacing of the footings
TEMPERATURE EFFECT
11.1 Air temperature range considered from 5 to 55 degree.
Ruwi tower
Page 5 of 5