You are on page 1of 1

PTFE Single core: NEMA HP-3 250V/200 - 260oC

ET xxxx Application:
Equipment wire

Equipment wire
ET xxxx NPC PTFE is Habia Cable’s foremost insulation material, intended for use up to 260oC. PTFE has excellent
mechanical properties, including solder resistance and offers unparalleled electrical performance. Typical
applications for PTFE include gas ignition wires, gas turbines, vacuum applications and high temperature
250/500V data cables. Cores are designed according to NEMA HP-3.
-65oC to +200oC (SPC)
-65oC to +260oC (NPC) Wire construction:
Conductor: ET xxxx: Silver Plated Copper (SPC)
Flame Retardant
ET xxxx NPC: Nickel Plated Copper (NPC)
Low Smoke Generation Insulation: Ram-extruded PTFE insulation
NEMA HP-3
RoHS Compliant Alternative option of Wrapped & Sintered PTFE Insulation:
Insulation: For wrapped & sintered, exchange the first digit ‘5 for a ‘3’ for SPC or ‘4’ for a ‘2’ for NPC
(e.g. RET 3207 Black = 311003207 or RET 3207 NPC Black = 211003207)

Available colours: 00 11 22 33 44 55 66 77 88 99 29 89 45
Replace ‘cc’ in the order reference with resistor colour code
(e.g. ET 3207 Black = 511003207) Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Natural Yw/Gn

Description Size Conductor Finished Wire Amps Order Reference


weight at 40oC prefix colour /
AWG mm 2
stranding wire Ø core Ø tolerance size
(kg/km) SPC NPC SPC NPC
ET 3207 ... 32 0,04 7 x 0,08 0,24 0,56 ±0,05 0,80 3 4 511 411 cc3207
ET 3001 ... 30 0,05 1 x 0,25 0,25 0,56 ±0,05 0,90 4 5 511 411 cc3001
ET 3007 ... 30 0,06 7 x 0,10 0,30 0,61 ±0,05 1,00 4 5 511 411 cc3007
ET 2801 ... 28 0,08 1 x 0,32 0,32 0,64 ±0,05 1,20 6 7 511 411 cc2801
ET 2807 ... 28 0,09 7 x 0,13 0,38 0,69 ±0,05 1,50 6 7 511 411 cc2807
ET 2601 ... 26 0,13 1 x 0,40 0,40 0,71 ±0,05 1,70 8 9 511 411 cc2601
ET 2607 ... 26 0,14 7 x 0,16 0,48 0,79 ±0,05 2,10 8 9 511 411 cc2607
ET 2619 ... 26 0,16 19 x 0,10 0,48 0,79 +0,07 -0,05 2,20 8 9 511 411 cc2619
ET 2401 ... 24 0,20 1 x 0,51 0,51 0,81 ±0,05 2,50 10 12 511 411 cc2401
ET 2407 ... 24 0,22 7 x 0,20 0,60 0,91 ±0,05 3,00 10 12 511 411 cc2407
ET 2419 ... 24 0,24 19 x 0,13 0,60 0,91 +0,08 -0,05 3,20 10 12 511 411 cc2419
ET 2201 ... 22 0,32 1 x 0,64 0,64 0,95 +0,07 -0,06 3,70 14 16 511 411 cc2201
ET 2207 ... 22 0,36 7 x 0,25 0,76 1,07 ±0,05 4,40 14 16 511 411 cc2207
ET 2219 ... 22 0,38 19 x 0,16 0,76 1,07 +0,10 -0,05 4,70 14 16 511 411 cc2219
ET 2001 ... 20 0,52 1 x 0,81 0,81 1,12 ±0,05 5,60 19 22 511 411 cc2001
ET 2007 ... 20 0,56 7 x 0,32 0,96 1,27 ±0,05 6,60 19 22 511 411 cc2007
ET 2019 ... 20 0,60 19 x 0,20 0,96 1,27 ±0,05 7,10 19 22 511 411 cc2019

De-rating factors for current rating


ET xxxx 20 40 60 80 100 120 140 160 180 - - - - -
Temperature de-rating (oC) 1.08 1.00 0.92 0.84 0.75 0.65 0.55 0.42 0.28 - - - - -
ET xxxx NPC 20 40 60 80 100 120 140 160 180 200 220 240 - -
Temperature de-rating (oC) 1.06 1.00 0.94 0.88 0.80 0.76 0.69 0.61 0.54 0.45 0.35 0.23 - -
2 3 4 6 8 10 12 16 20 24 28 32 36 40
Multicore de-rating factor
1.00 0.88 0.80 0.69 0.62 0.59 0.55 0.51 0.48 0.43 0.41 0.39 0.38 0.36
Note: All dimensions in mm and ±4% unless stated Date: 2010-05-14 Created: CJV Approved: TN Reference: EQ_ET_10
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

22 world class cable solutions www.habia.com