Table of Contents
Topic
Page
1. Architectural Design ....
.. x
2. Model Data ..
. x
2.1 Activity Tab ......
..... x
2.1.1 Occupancy ...
x
2.1.2 Environmental Control .
. x
2.2 Construction Tab .....
..... x
2.2.1 External Walls ......
x
2.2.2 Internal Partitions ....
. x
2.2.3 Flat Roof .....
. x
2.2.4 Ground Floor .......
. x
. x
2.2.6 External Floor ..........
. x
2.2.7 Infiltration Rate .......
. x
2.3 Openings Tab .......
..... x
2.4 Lighting Tab ........
..... x
2.5 HVAC Tab ..............
.. x
3. Load Calculations ..
. x
3.1 Heating Load Calculations .........
..... x
3.2 Cooling Load Calculations .........
..... x
1.
Architectural Design
2.
Model Data
Occupancy
Area
No.
of Occupancy
Density
2.1.2
Environmental Control
a) Heating and cooling setpoint temperatures:
Put the heating and cooling setpoint temperatures for the zones of
your model in a table like the following:
Zone
Heating
Setpoint Cooling
Setpoint
b) Humidity control:
Write the used RH humidification setpoint and RH dehumidification
setpoint in your model.
c) Minimum fresh air:
Put the used values for minimum fresh air in each zone of your
model in a table like the following:
Zone
External Walls
State the layers of the external walls used in your model and
support that with an image for the wall layers and the graph of
condensation analysis, also mention the U-Value for the wall.
2.2.2
Internal Partitions
State the layers of the internal partitions used in your model and
support that with an image for the partition layers and the graph
of condensation analysis, also mention the U-Value for the
partition.
2.2.3
Flat Roof
State the layers of the roof used in your model and support that
with an image for the roof layers and the graph of condensation
analysis, also mention the U-Value for the roof.
2.2.4
Ground Floor
State the layers of the ground floor used in your model and
support that with an image for the ground floor layers and the
graph of condensation analysis, also mention the U-Value for the
ground floor.
2.2.5
Internal Floor
State the layers of the internal floor used in your model and
support that with an image for the internal floor layers and the
graph of condensation analysis, also mention the U-Value for the
internal floor.
2.2.6
External Floor
If you have an external floor in your model, state the layers of the
external floor used in your model and support that with an image
for the external floor layers and the graph of condensation
analysis, also mention the U-Value for the external floor.
2.2.7
Infiltration Rate
3.
Load Calculations
Steady-State Heat
Loss (kW)
Design
Capacity (kW)
Design Capacity
(W/m)
Sensi
ble
(kW)
Latent
(kW)
Total Cooling
Load (kW)
5
Design
Capacity (kW)
4.
5.
State the annual CO2 emissions of the building (support that with a
graph).
6.