You are on page 1of 4

Discharge Muffler

Cancels: IIK 693C-24-1

IIK 693C-24-2
4-95

Installation Instructions
Part No. 321787-751 through -761
NOTE: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATIONS
Installing and servicing of heat pump equipment can be hazardous
due to system pressure and electrical components. Only trained
personnel should install or service heat pump equipment.
Untrained personnel can perform basic maintenance functions,
such as cleaning coils and cleaning and replacing filters. All other
operations should be performed by trained service personnel.
When working on heat pump equipment, observe precautions in
the literature, on tags, and on labels attached to unit.
Follow all safety codes. Wear safety glasses and work gloves. Use
a quenching cloth for brazing operations. Have a fire extinguisher
available.

Do not use torch to remove components. Oil may catch fire.


Use tubing cutters. Refer to service instructions.

Do not vent refrigerant to atmosphere. Recover during system


repair or final unit disposal. Use all service ports.
1. Turn off power and reclaim refrigerant in system.
2. Cut discharge tube near compressor and reversing valve then
unbraze stubs.
3. Remove check valve, high-pressure switch, and solenoid valve
(if used) from the discharge tube. DO NOT discard these
components as they will be reused.

Before beginning the installation or modification, be sure the


main electrical disconnect switch is in the OFF position.
Electrical shock can cause personal injury or death.
Avoid overheating as damage to components could occur.
INTRODUCTION
This instruction covers installation of a discharge muffler kit. The
discharge muffler is designed to reduce or alleviate noise transmission through connecting tubing. The objectionable noise can be
caused by discharge gas pulsations during the heating mode in heat
pump applications.
DESCRIPTION AND USAGE
The discharge muffler kit contains a discharge muffler, preformed
copper tubes, and Installation Instructions. Refer to Table 1 for kit
contents and appropriate figure for installation on specific models.

4. Wrap a wet rag around the reversing valve to protect it from


heat. Remove and discard existing discharge tube located
between compressor and reversing valve.
5. Install muffler kit as shown in Fig. 1, 2, or 3.
6. Install previously removed check valve, high-pressure switch,
and solenoid valve (if used). A hole is provided in each tube
for the high-pressure switch and solenoid.
7. Braze all joints and check system for leaks.
8. Evacuate, charge, and start system.

INSTALLATION
Follow all common service practices in addition to the instructions
below when installing this kit.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
PC 101
Catalog No. 533-851
Printed in U.S.A.
Form 38Y-20SI
Pg 1
4-95
Replaces: 38Y-19SI
Tab 5a 5a

Table 1Kit Contents and Figure Reference Numbers


PART NO.

PART NAME
Muffler

321787-751

Copper Tubes
Installation Instructions
Muffler

321787-752

Copper Tubes
Installation Instructions
Muffler

321787-753

IIK

Copper Tubes
Installation Instructions
Muffler

321787-761

IIK

Copper Tubes
Installation Instructions
Muffler

321787-760

IIK

Copper Tubes
Installation Instructions
Muffler

321787-759

IIK

Copper Tubes
Installation Instructions
Muffler

321787-757

IIK

Copper Tubes
Installation Instructions
Muffler

321787-756

IIK

Copper Tubes
Installation Instructions
Muffler

321787-755

IIK

Copper Tubes
Installation Instructions
Muffler

321787-754

IIK

IIK

Copper Tubes
Installation Instructions

IIK

PART NO.
LM10KK010
321782-301
321783-302
693C-24-1/38Y-19SI
LM10KK010
321782-302
321784-301
693C-24-1/38Y-19SI
LM10KK010
321404-304
321402-301
693C-24-1/38Y-19SI
LM10KK010
321404-305
321785-301
693C-24-1/38Y-19SI
LM10KK010
321782-302
321784-302
693C-24-1/38Y-19SI
LM10KK010
321404-302
321402-301
693C-24-1/38Y-19SI
LM10KK010
321404-303
321402-301
693C-24-1/38Y-19SI
LM10KK010
321404-305
321405-301
321401-202
693C-24-1/38Y-19SI
LM10KK010
321404-305
321405-302
321401-201
693C-24-1/38Y-19SI
LM10KK010
321404-306
321405-301
321401-202
693C-24-1/38Y-19SI

USED WITH

FIG. NO.

38YKB024

693C024

38YKB030

693C030

38YKB036
38YKB042
38YR042
38YS042

693C036
693C042
697B042
697H042

38YKB048
38YKB060

693C048
693C060

38YR024
38YS024

697B024
697H024

38YR030
38YS030

697B030
697H030

38YR036
38YS036

697B036
697H036

38YS048

697H048

38YR048

697B048

38YR060

697B060

NEW TUBE
EXISTING PRESSURE
SWITCH
NEW
TUBE

EXISTING
COMPRESSOR

EXISTING
REVERSING
VALVE

NEW MUFFLER

Fig. 1Part No. 321787-751, 752, 755


NEW MUFFLER

A94063

NEW
TUBE

EXISTING
PRESSURE
SWITCH
NEW
TUBE
EXISTING
REVERSING
VALVE
EXISTING
COMPRESSOR
A94064

Fig. 2Part No. 321787-753, 754, 756, 757


EXISTING
SOLENOID VALVE

NEW TUBE

EXISTING
COMPRESSOR
NEW
MUFFLER

NEW TUBE

EXISTING
CHECK VALVE

EXISTING
PRESSURE
SWITCH
EXISTING
REVERSING
VALVE
NEW
TUBE

A94080

Fig. 3Part No. 321787-759, 760, 761


3

Copyright 1995 Carrier Corporation

693c242

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
PC 101
Catalog No. 533-851
Printed in U.S.A.
Form 38Y-20SI
Pg 4
4-95
Replaces: 38Y-19SI