Typical application
LED
lamps
Applications
Battery chargers
Low voltage LED light towers
Power supply of auxiliary circuits, high/medium voltage
disconnectors coils, signalling devices
Power supply of monitoring and alarm systems
Battery charger
G
Low voltage LED light towers
G
G
General features
AVR electronic voltage regulation
Based on three-phase synchronous alternators
1500 rpm or 3000 rpm with large speed tollerance
Constant DC output voltage
Adjustable output voltage
Current overload protection
Fan cooled
Complying with EN 60034-1, IEC 60034-1, ISO 8528-3
Capacity table
Sectors of use
es
Telecommunications
Industry
Transports
Military
Advantages
High voltage stability in a large speed range
High efficiency
Low voltage ripple
High reliability
Available with the most common couplings
Fast recovery time during transient by step load variation
kW
3,6
4,8
7,2
9,6
12
14,4
16,8
19.2
21,6
24 V
current
150A
200A
300A
400A
500A
600A
700A
800A
900A
4 poles
model
Om-B4-24/150
Om-B4-24/200
Om-B4-24/300
Om-B4-24/400
Om-B4-24/500
Om-B4-24/600
Om-B4-24/700
Om-B4-24/800
Om-B4-24/900
kW
7,2
9,6
14,4
19.2
24
28.8
33,6
38,4
43,2
48 V
current
150A
200A
300A
400A
500A
600A
700A
800A
900A
model
OM-B4-48/150
OM-B4-48/200
OM-B4-48/300
OM-B4-48/400
OM-B4-48/500
OM-B4-48/600
OM-B4-48/700
OM-B4-48/800
OM-B4-48/900
Electrical data
Type
Technology
Fixed speed
Over speed
Underspeed protection
Nominal voltage
Adjustable output voltage
Output current
Max output power (Watt)
Efficiency (3/4 load)
Current limit protection
Ripple (2)
Insulation class
Temperature rise class
IP protection
Operating temperature range
Electromagnetic compatibility
OM - IB
three-phase synchronous with AVR
brushes
brushless
1500 or 3000 rpm (1)
+ 20%
included
24 VDC or 48 VDC (1)
from 23 VDC to 31 VDC
or from 48 VDC to 58 VDC (1)
see selection table @ 24 VDC or 48 VDC
Current (A) x 24 (VDC) or 48 (VDC)
> 0,80
included
without load < 8%
with full resistive load < 6%
with batteries < 3%
H
H
IP23
- 20 C to + 40 C (until + 55 C with derating)
EN 61000-6-2 , EN 61000-6-4
(1) see capacity table (2) on request reinforced filter for ripple reduction
25 C
1,05
40 C
1
45 C
0,96
50 C
0,92
55 C
0,88
altitude
factor
1000m
1
1500m
0,96
2000m
0,93
2500m
0,9
3000m
0,86
Overall dimensions
model @ 24V
OM-B4-24/150
OM-B4-24/200
OM-B4-24/300
D
mm
329
329
329
B
mm
437
437
437
mass
Kg
63,2
59,2
70,6
OM-B4-24/400
OM-B4-24/500
OM-B4-24/600
OM-B4-24/700
OM-B4-24/800
OM-B4-24/900
506
506
506
506
576
576
570
570
570
570
640
640
150
160
170
180
195
205
model @ 48V
OM-B4-48/150
OM-B4-48/200
OM-B4-48/300
D
mm
329
329
329
B
mm
437
437
437
mass
Kg
63,2
59,2
70,6
OM-B4-48/400
OM-B4-48/500
OM-B4-48/600
OM-B4-48/700
OM-B4-48/800
OM-B4-48/900
506
506
506
506
576
576
570
570
570
570
640
640
150
160
170
180
195
205