HVAC DESIGN SOLUTIONS

ENGINEERING SOFTWARE

PLUMBING DESIGN
Essential
EssentialDesign
DesignPrograms
Programs
with
withAccurate
AccurateSizing
SizingCalculations
Calculations
help
helpto
toStreamline
StreamlineYour
YourDesign
Design
Copyright 2008 HVAC Design Solutions

Plumbing Design from HVAC Design


Solutions is a package of software programs
for most of the Plumbing Designers sizing
tasks:
Fixture Unit/GPM Calcs
Water System Sizing
Waste & Vent System Sizing
Roof Drain System Sizing
Natural Gas System Sizing
Water Heater Sizing
Extensive Help Files, and Extras
Copyright 2008 HVAC Design Solutions

Reduce your dependence on


Reference Books, Charts, Graphs,
and Rules of Thumb.
Eliminate many of the usual
Plumbing Design Tasks
Reduce common errors and mistakes
Create an easy-to-follow, step-bystep Procedure for Plumbing
Software Package contains most of
Design for all the
projects.
sizing calculations and
procedures for typical projects
Copyright 2008 HVAC Design Solutions

CONTENTS
PROJECT INFORMATION
BASIC PROJECT INPUT SHEET

PLUMBING CALCS DESIGN

JUMP TO FILE
INDEXP.xls#INDEX!C10
INDEXP.xls#PROJ.INFO!D2

indexp1.XLS#INDEX!C10

Quick Links to
all calculation
programs

FIXTURE UNIT CALCULATIONS

indexp1.XLS#'FU-CALCS'!B4

WATER PIPE SIZING CALCULATIONS

indexp1.XLS#PIPESIZE!B10

WASTE AND VENT PIPE SIZING

indexp1.XLS#'W&V SIZES'!B3

ROOF DRAINS, VERTICAL AND HORIZONTAL PIPE SIZING

indexp1.XLS#ROOFDR!G4

MEDICAL GAS PIPING CALCULATIONS - PRELIMINARY

indexp1.XLS#MEDGAS!D10

WATER FIXTURE UNIT TO GPM CONVERSIONS

indexp1.XLS#'FU-GPM'!A5

AIR COMPRESSOR CALCULATIONS

indexp1.XLS#AIRCOMP!B11

PLUMBING SCHEDULE DESIGN

Any One of these


programs is worth the cost
of the Entire Package!

indexp2.XLS#INDEX!C10

PRELIMINARY WATER PIPE SIZING SCHEDULE

indexp2.XLS#'WATER-SCHED1'!B10

WATER PIPE SIZING SCHEDULE

indexp2.XLS#'WATER-SCHED2'!A10

WASTE PIPE SIZING SCHEDULE

indexp2.XLS#'WASTE-SCHED'!B10

VENT PIPE SIZING SCHEDULE

indexp2.XLS#'VENT-SCHED'!B10

ROOF DRAIN, LEADER, OR VERTICAL PIPE SCHEDULE

indexp2.XLS#'ROOFDR-SCHED'!E3

HORIZONTAL ROOF DRAINAGE PIPING SCHEDULE

indexp2.XLS#'STORMPIPE-SCHED'!D4

WATER HEATER SIZING CALCULATIONS

indexp2.XLS#'WATERHTR-CALCS'!C6

NATURAL GAS PIPE SIZING SCHEDULE - LOW PRESSURE

indexp2.XLS#'GAS-SCHED1'!F3

NATURAL GAS PIPE SIZING SCHEDULE - MEDIUM PRESSURE

indexp2.XLS#'GAS-SCHED2'!F3

GAS PIPE SIZING DIAGRAM

indexp2.XLS#'GASPIPE-DIAG.'!E1

Copyright 2008 HVAC Design Solutions

"YOUR COMPANY NAME"

BASIC PROJECT INFORMATION

HELP

Begin with Basic Project


Information input

PROJECT NAME :

OAKPARK OFFICE BLDG. 3

PROJECT NUMBER :

134-08

PROJECT LOCATION :
DATE :
TYPE OF BUILDING :

Information automatically
transfers to all programs

CHICAGO, IL
05/06/08
OFFICE

SUMMER OUTDOOR DESIGN DRY BULB TEMP. (DEG. F):

91.0

WINTER OUTDOOR DESIGN DRY BULB TEMP. (DEG. F):

-6.0

INDOOR DESIGN TEMP. - SUMMER (DEG. F) :

75.0

INDOOR DESIGN TEMP. - WINTER (DEG. F) :

70.0

PROJECT ELEVATION (FEET) :

670

PROJECT MANAGER :

BILL REECE

PROJECT ENGINEER :
CLIENT :
CLIENT CONTACT NAME:

Design Conditions are


used in some calculations

JIM EDMOND
ADS ARCHITECTS
JOHN GOREMANN

Copyright 2008 HVAC Design Solutions

FIXTURE UNIT CALCULATIONS


RESET/CLEAR
FLUSH VALVES = 1, FLUSH TANKS = 2

FIXTURE TYPE

PROJECT NUMBER:

PRINT

Count the Fixtures for the project and


input the quantities of each type
QUANTITY

PROJECT NAME:

DATE:

COLD WATER FIXTURE UNITS


HOT WATER FIXTURE UNITS *
*
FU EACH

TOTAL FU

FU EACH

TOTAL FU

3.0

6.0

3.0

6.0

BATHTUB WITH 3/4" FILL VALVE

8.0

0.0

8.0

0.0

BIDET

1.0

0.0

1.0

0.0

3.0

0.0

3.0

0.0

0.5

1.5

0.0

0.0

BATHTUB OR COMBINATION BATH/SHOWER

CLOTHES WASHER, DOMESTIC

Fixture
Unit 0.0Values may
be edited
to
1.0
1.0
0.0
meet
1.5 local Codes
0.0
1.5
0.0

DENTAL UNIT, CUSPIDOR


DISHWASHER, DOMESTIC
DRINKING FOUNTAIN OR WATERCOOLER

Copyright 2008 HVAC Design Solutions

SINKS - SERVICE OR MOP BASIN, 3" DRAIN

2.5

5.0

2.5

5.0

20.0

0.0

0.0

0.0

SINKS - SPECIAL PURPOSE, 2" DRAIN

2.5

0.0

2.5

0.0

SINKS - SPECIAL PURPOSE, 3" DRAIN

2.5

0.0

2.5

0.0

SINKS - WASHUP, EACH SET OF FAUCETS

1.5

0.0

1.5

0.0

13.3

53.0

0.0

0.0

URINAL, GREATER THAN 1.0 GPF FLUSH VALVE

0.0

0.0

0.0

0.0

URINAL, FLUSH TANK

2.0

0.0

0.0

0.0

2.5

0.0

0.0

0.0

20.8

125.0

0.0

0.0

WATER CLOSET - GREATER THAN 1.6 GPF TANK

5.5

0.0

0.0

0.0

WATER CLOSET - GREATER THAN 1.6 GPF VALVE

0.0

0.0

0.0

0.0

SINKS - SERVICE, FLUSHING RIM

URINAL, 1.0 GPF FLUSH VALVE

Input3.0Fixture0.0Quantities,
and the
3.0
0.0 Total
3.0
3.0 calculated,
0.0
FU and
Total0.0GPM are
per
0.0
0.0
0.0
Local2.5 Code requirements

WASHFOUNTAIN, 1-1/2" DRAIN


WASHFOUNTAIN, 2" DRAIN
WATER CLOSET - 1.6 GPF GRAVITY TANK
WATER CLOSET - 1.6 GPF FLUSHOMETER TANK
WATER CLOSET - 1.6 GPF FLUSH VALVE

KITCHEN EQUIPMENT - WATER GPM


TOTALS

201.5

17.0

COLD WATER
FU

HOT WATER
FU

Copyright 2008 HVAC Design Solutions

PROJECT NAME:

Total FLUSH
Demand
VALVEStransferred
= 1, FLUSH TANKS = 2
from Fixture Unit Totals

PRINT

PROJECT NUMBER:
DATE:

AVAILABLE WATER PRESSURE CALCULATIONS

PIPE SIZE SCHEDULE (@ MAX. ALLOWABLE


SIZE

MAX. GPM

VEL.

DEMAND FLOW RATE (GPM)

94

1/2

1.4

WATER MAIN PRESSURE (PSIG)

100

3/4

3.2

11

3.9

80

1 1/4

PRESSURE DROP THRU METER (PSIG)


PRESSURE REDUCING VALVE - PRESSURE (IF REQUIRED)
PRESSURE DROP THRU BACKFLOW PREVENTER (PSIG)

STATIC HEIGHT OF HIGHEST FIXTURE ABOVE MAIN (FT)

30

PRESSURE DROP THROUGH WATER TREATMENT (PSIG)

10

2 1/2

110

RESIDUAL PRESSURE REQUIRED AT LAST OUTLET (PSIG)

25

180

6.5

PRESSURE AVAILABLE FOR PIPING LOSS (PSIG)

27

300

PRESSURE BOOSTER PUMP (IF REQUIRED) (PSIG)

13

24
5.2
Adding
Project
specific
1 1/2
32
5.6
information...
2
67
6.2

TOTAL DEVELOPED LENGTH OF LONGEST PIPE RUN (FT)

600

MAXIMUM ALLOWABLE PIPE PRESS. DROP (PSIG/100 FT)

4.5

Copyright 2008 HVAC Design Solutions

460
6.8
Results
in Allowable
700
8
Pipe1200Pressure
Drop/100
8.2
for Longest Run
sizing

Max. Allowable PD/100


Automatically transferred to
Pipe Section Sizing Calcs
PRELIMINARY WATER PIPE SIZING SCHEDULE
MAXIMUM ALLOWABLE PRESSURE
DROP - LONGEST RUN (PSIG/100 FT.)

PROJECT NUMBER:

ERROR NOTE: INPUT EITHER FLUSH TANK OR FLUSH

PRINT

VALVE, NOT BOTH.

PIPE SECTION

FLUSH TANK
FIXTURE UNITS
(FU)

FLUSH VALVE
FIXTURE UNITS
(FU)

DATE:
NUMBER OF EACH TYPE FITTING IN THE

FLOW RATE
(GPM)

PIPE SIZES
FOR MAIN
(LONGEST
RUN)

90 DEG.
STANDARD
ELBOW

FROM

TO

3/4

42

25

1 1/2

250

100

2 1/2

475

135

2 1/2

Input FU values for


each pipe section

PROJECT NAME:

RESET/CLEAR

4.5

Copyright 2008 HVAC Design Solutions

45 DEG.
STANDARD
ELBOW

90 DEG.
STANDARD TEE
(FLOW TURNS)
1

Input fittings and


valves for each
pipe section

MAXIMUM ALLOWABLE PRESSURE DROP LONGEST RUN (PSIG/100 FT.)

ERROR

Final, Accurate Pipe


Section sizing, after
WATER PIPE SIZING SCHEDULE
corrections
for actual
PROJECT NAME:
RESET/CLEAR
4.5
fittings
valves
PROJECTand
NUMBER:

NOTE: INPUT EITHER FLUSH TANK OR FLUSH


VALVE, NOT BOTH.

PIPE SECTION

PRINT

DATE:
PIPE SIZES FOR MAIN (LONGEST RUN)

FLUSH TANK
FIXTURE UNITS
(FU)

FLUSH VALVE
FIXTURE UNITS
(FU)

FLOW RATE
(GPM)

MAIN SIZE
(INCHES)

MAIN SIZE PD
(PSI/100 FT.)

MAIN SIZE
VELOCITY
(FT./SEC.)

FROM

TO

3/4

2.2

2.7

42

25

1 1/2

2.5

4.5

120

72

2 1/2

1.7

5.0

250

100

2 1/2

2.9

7.0

0.0

0.0

0.0

0.0

Accurate Pipe sizing,0NOT


based on Rule-of-Thumb,
like add 50% for Fittings!!
Copyright 2008 HVAC Design Solutions

10

WASTE & VENT SIZING AND MAX. LENGTHS


WASTE FIXTURE UNITS (FU):

30

WASTE SLOPE (1/4=1, OR 1/8=2):

WASTE SIZE - VERT.:

2 1/2

WASTE VERTICAL LENGTH (FT.):

65

WASTE SIZE - HORIZ.:

VENT FIXTURE UNITS (FU):

30

VENT TOTAL LENGTH (FT.):

46

VENT SIZE:

2 1/2

VENT HORIZONTAL LENGTH (FT.):

12

Quick input of pipe


section loading and
lengths (W and/or V)

Resulting sizes for the section

MAXIMUM UNIT LOADING AND MAXIMUM LENGTH OF DRAINAGE AND VE


SIZES
1 1/4

MAXIMUM UNITS

1 1/2

2 1/2

Cross reference in chart form

DRAINAGE PIPING (#1)


VERTICAL

2 (#2)

16 (#3)

32 (#3)

48 (#4)

256

HORIZONTAL @ 1/4"/FT. SLOPE

8 (#3)

14 (#3)

35 (#4)

216 (#5)

HORIZONTAL @ 1/8"/FT. SLOPE

N/A

N/A

N/A

N/A

N/A

172 (#5)

Copyright 2008 HVAC Design Solutions

11

WASTE PIPE SIZING SCHEDULE


PROJECT NAME:

RESET/CLEAR

Input W-FU and vertical length


PRINT
for each pipe
section
WASTE PIPE SECTION

PROJECT NUMBER:
DATE:

HELP

OAKPARK OFFICE BLDG. 3


134-08

Required sizes at different slopes


are05/06/08
calculated automatically

WASTE FIXTURE
UNITS (FU)

WASTE PIPE
VERTICAL
LENGTH
(FT.)

WASTE PIPE
SIZE VERTICAL

WASTE PIPE
SIZE AT
1/4"/FT.
SLOPE

WASTE PIPE
SIZE AT
1/8"/FT.
SLOPE

NUMBER OF
WATER
CLOSETS ON
PIPE SECTION

FROM

TO

12

2 1/2

22

34

Copyright 2008 HVAC Design Solutions

12

VENT PIPE SIZING SCHEDULE


CAUTION

EITHER TOTAL LENGTH OR


HORIZONTAL LENGTH
EXCEEDS CODE MAXIMUM
ALLOWABLE. SIZE HAS BEEN
INCREASED BY ONE PIPE
SIZE.

VENT PIPE SECTION

HELP

PROJECT NAME:

RESET/CLEAR
Input
V-FU, total length,
PROJECT NUMBER:
and horizontal length
for
PRINT
each pipe sectionDATE:

OAKPARK OFFICE BLDG. 3


134-08
05/06/08

VENT FIXTURE
UNITS (FU)

VENT PIPE
TOTAL
LENGTH
(FT.)

VENT PIPE
HORIZONTAL
LENGTH
(FT.)

VENT PIPE SIZE


(IF TOTAL AND
HORIZ. LEN.
LESS THAN
ALLOWABLE
LENGTH)

VENT PIPE SIZE


(IF TOTAL LEN.
MORE THAN
ALLOWABLE
LENGTH)

VENT PIPE SIZE


(IF HORIZ. LEN.
MORE THAN 1/3
OF ALLOWABLE
TOTAL LENGTH)

FROM

TO

20

110

35

30

190

55

45

100

70

65

30

150

60

20

Copyright 2008 HVAC Design Solutions

Required
0 sizes are 0
calculated automatically

13

Input Local
Rainfall Rate
ROOF DRAIN, LEADER, OR VERTICAL PIPE SCHEDULE
RAINFALL RATE FOR 100 YEAR, 60
MINUTE DURATION STORM IN
LOCAL AREA (INCHES/HR.):

Input Roof Area


served by Roof Drain
DRAIN
NUMBER

ROOF AREA
(SQ. FT.)

(1) ADJACENT
WALL - AREA
(SQ. FT.)

1500

1000

2500

3000

1000

3.00

PROJECT NAME:
PROJECT NUMBER:

RESET/CLEAR

DATE:
PRINT

HELP

OAKPARK OFFICE BLDG. 3

Roof Drain
size or
134-08
Vertical Pipe
05/06/08 sizes
are calculated

SIZE OF ROOF
DRAIN, LEADER,
OR VERTICAL
PIPE (IN.)

FLOW RATE
(GPM)

MAXIMUM AREA
DRAIN OR PIPE
SIZE CAN CARRY
(SQ. FT.)

2000

67

2147

1200

2920

144

4613

2500

3875

144

4613

1000

67

2147

(2) ADJACENT TOTAL AREA WALLS - AREA ROOF + WALLS


(SQ. FT.)
(SQ. FT.)

Input Adjacent Wall Area


where applicable
Copyright 2008 HVAC Design Solutions

14

Input Local
Rainfall Rate

HORIZONTAL ROOF DRAINAGE PIPING SCHEDULE


PROJECT NAME:

RAINFALL RATE FOR 100 YEAR,


60 MINUTE DURATION STORM IN
LOCAL AREA (INCHES/HR.):

Horizontal
RESET/CLEARRoof Drainage
PROJECT NUMBER:
Pipe Section sizes are
DATE:
PRINT for 1/8, 1/4,
calculated
and 1/2 pipe slopes

3.00

Input Roof Area served


by Pipe Section
PIPE SECTION

ROOF AREA
(SQ. FT.)

(1) ADJACENT
WALL - AREA
(SQ. FT.)

HORIZ. PIPE
(2) ADJACENT TOTAL AREA SIZE AT 1/8"/FT.
WALLS - AREA ROOF + WALLS
SLOPE
(SQ. FT.)
(SQ. FT.)
(INCHES)

FLOW RATE
AT 1/8"/FT.
SLOPE
(GPM)

1200

4100

139

FROM

TO

3500

2000

3000

3050

139

5500

4500

7075

222

3000

3000

139

Input Adjacent Wall Area


where applicable
Copyright 2008 HVAC Design Solutions

15

WATER HEATER SIZING CALCULATIONS


PROJECT NAME:

HOSPITAL

TYPE OF BUILDING OR FACILITY:

RESET/CLEAR
FACILITY INCLUDE FULL KITCHEN? 1 = YES, 2 = NO

NUMBER:
SelectPROJECT
Type
of Facility
fromDATE:
drop-down list
PROJECT ELEVATION:

PRINT

PLUMBING FIXTURE TYPE

QUANTITY

HOT WATER - GALLONS PER


HOUR AT 140 DEG. F
GPH EACH

TOTAL GPH

KITCHEN FIXTURE TYPE


(ASSUMING SEPARATE BOOSTER
HEATER FOR 140 DEG. F TO 180 DEG.
F HOT WATER WHERE REQUIRED)

GENERAL PLUMBING FIXTURES:


BATHTUB FILL (EXCLUDING WHIRLPOOL TUBS)

KITCHENS:
20

DISHWASHER - FROM MANUFACTURER, IF AVAIL.

DISHWASHER - DOOR TYPE - WITHOUT INTERN

BATHTUB AND SHOWER

75

375

BIDET

16 x 16 IN. RACKS

DISHWASHER - DOMESTIC UNDERCOUNTER

15

18 x 18 IN. RACKS

FOOT BASIN

20 x 20 IN. RACKS

LAUNDRY - DOMESTIC, STATIONARY TUB

28

UNDERCOUNTER TYPE

LAVATORY - PRIVATE

LAVATORY - PUBLIC

75

225

SHOWER - SINGLE HEAD

Copyright 2008 HVAC Design Solutions

DISHWASHER
- CONVEYOR
- WITHOUT INTE
Input
quantity
ofTYPE
each
SINGLE TANK
Fixture Type
MULTIPLE TANK (DISHES FLAT)

16

LAVATORY - PUBLIC

SHOWER - GENERAL
SHOWER - THERAPEUTIC

UTINSIL WASHERS

50

DISHWASHER MAKEUP WATER REQ.

400

15

15

HAND SINK

SINK - CLEANUP ROOM

15

15

DOUBLE POT SINK

SINK - CENTRAL SUPPLY

15

15

PREFLUSH (CLOSED TYPE)

SINK - CLINICAL

10

10

PREFLUSH (HAND-OPERATED)

15

PRESCRAPPER (OPEN TYPE)

SINK - CLINICAL, BEDPAN HOSE

75

139

60

240

45

45

180

40

KITCHEN FIXTURES:

SINK - BARIUM

Demand Factor and


Storage Factor are applied
to Max. Demand, based
on Type of Facility

Input Kitchen Fixtures,


as applicable

SINK - LABORATORY

10

RECIRCULATING PREFLUSH

SINK - PHARMACY

SINGLE POT SINK

30

30

SINK - PLASTER

15

15

TRIPLE POT SINK

90

90

SINK - SCRUB-UP

10

20

VEGETABLE SINK

45

45

POSSIBLE MAXIMUM DEMAND - FIXTURES (GPH):

1424

POSSIBLE TOTAL MAXIMUM DEMAND (GPH):

1919

DEMAND FACTOR:

ALTITUDE CORRECTION FACTOR (IF ANY):

0.25

PROBABLE MAXIMUM DEMAND (GPH):


STORAGE CAPACITY FACTOR:

480

288

495

1.00

REQUIRED WATER HEATER OUTPUT (AT 140 DEG. F) (BTUH):


USABLE STORAGE CAPACITY FACTOR:

0.60

STORAGE TANK CAPACITY (GALLONS):

POSSIBLE MAXIMUM DEMAND - KITCHEN (GPH):

REQUIRED STORAGE TANK CAPACITY (GALLONS):

359669

0.70
411

Resulting in required Water Heater Output


and required Storage Tank Capacity
Copyright 2008 HVAC Design Solutions

17

Start with a sketch of


the Gas Piping system

Copyright 2008 HVAC Design Solutions

18

1. Input Local
Gas conditions

NATURAL GAS PIPE SIZING SCHEDULE (LOW PRESSURE - BELO


INITIAL GAS PRESSURE (IN. WC) (28" WC PER PSI)

28.00

1.00

(PSI)

ALLOWABLE PRESSURE DROP (IN. WC)

2.00

0.07

(PSI)

GAS SPECIFIC GRAVITY

0.60

1.000
MEASURED LENGTH
BRANCH - FROM
METER (WITHOUT
FITTINGS) (FEET)

PIPE SECTION

GAS FLOW
RATE (CFH)

MEASURED LENGTH
MAIN - LONGEST RUN
(WITHOUT FITTINGS)
(FEET)

PIPE SIZES
FOR MAIN
(LONGEST
RUN)

FROM

TO

150

570

450

570

1 1/2

750

570

2500

570

2565

570

300

300

1750

10

65

0
0
2. Input Flow Rate
and
0
Lengths for Longest
0
Run and Branches

RESET/CLEAR

(SG MULT)

PRINT

NUMBER OF EACH FIT


PIPE SIZES FOR
BRANCH

90 DEG.
STANDARD
ELBOW

3. Input Fittings 0
and Valves for 0
0
each section

500

1 1/4

460

1 1/4

420

320

3/4

Copyright 2008 HVAC Design Solutions

4. Sizes are
calculated for
each Section
19

MEDICAL GAS SERVICE TYPE

QUANTITY

DESIGN FRICTION LOSS

DIVERSITY FACTOR

PSI PER 100 FT.

IN. HG PER 100 FT.

PERCENT (%)

OXYGEN (O2)
NUMBER OF STANDARD OUTLETS

24

1.00

---

33

NUMBER OF RESPIRATORY VENTILATORS

1.00

---

100

18

1.00

---

50

NITROUS OXIDE (N 2O)


NUMBER OF STANDARD OUTLETS

NITROGEN (N 2)
NUMBER OF STANDARD OUTLETS

Initial Pipe Sizing for Med.


Gas Systems
--75

18

2.00

24

1.00

---

60

NUMBER OF STANDARD OUTLETS

18

---

1.00

60

NUMBER OF MAJOR SURGERY ROOMS

---

1.00

100

NUMBER OF INTENSIVE CARE BEDS

---

1.00

50

MEDICAL AIR (MA)


NUMBER OF STANDARD OUTLETS

MEDICAL VACUUM (VAC)

Copyright 2008 HVAC Design Solutions

20

TOOL OR EQUIPMENT

QUANTITY

FREE AIR USAGE AT 90 PSIG


1

USE FACTOR

(CFM)

AIR HOIST - 1,000 LB. OR LESS

0.8

AIR HOIST - 2,000 LB. TO 10,000 LB

35

0.8

AIR HOIST - 10,000 LB. AND LARGER

105

0.8

ANGLE NUT SETTER - TO 5/16" (WEIGH 8 LBS.)

20

0.8

ANGLE NUT SETTER - 1/2" TO 3/4" (WEIGH 18 LBS.)

30

0.8

BLOWGUNS

25

0.8

BUSHING TOOLS (MONUMENTAL)

25

0.8

CARVING TOOLS (MONUMENTAL)

15

0.8

12

0.8

30

0.8

CHIPPING HAMMERS (WEIGH 2 - 4 LBS.)

CHIPPING HAMMERS (WEIGH 10 - 13 LBS.)


CHIPPING HAMMERS (HEAVY WEIGHT)
CONCRETE VIBRATORS

Calculates Total
Usage &
39 Anticipated 0.8
Recommended30Receiver Volume
0.8

FILE AND BURR MACHINES

18

0.8

GREASE GUN

0.8

10

0.8

20

0.8

GRINDERS - HORIZONTAL (1-1/2" WHEELS AND UNDER)


GRINDERS - HORIZONTAL (2" AND 2-1/2" WHEELS)

Copyright 2008 HVAC Design Solutions

21

Coordination Between Disciplines


Contents:
A
B
C
D
E
F
G
H
A

(Click on hyperlink to jump to the sheet checklist)

Preliminary Review of Plans and Specifications


Demolition Plans
Arc hitect and/or Owner Coordination
Structural Coordination
Mechanical Coordination
Plumbing Coordination
Civil Engineering Coordination
Electrical Coordination

Preliminary Review of Plans and Specifications


1 Quickly review all Drawings in the Construction Document set, including Architectural,
Structural, Civil, Landscaping, Mechanical, Plumbing, Fire Protection, Electrical, Food
Service, and any other discipline. Spend not more than one minute per sheet, average.
2 Make a list of any apparent discrepancies or questions while reviewing the set, and add
flags to sheets where there are significant questions.
3 Quickly review the Specifications by reading through the Table of Contents for
Mechanical and Plumbing work. Check the Table of Contents against the actual
Specification sections to verify all sections have been included. Make a list of questions
that may come up during the cursory review.
4 Review Architectural T itle Sheet, or first sheet in the set, and make a list of the Project
Square Footage, Building Occupancy Type, Building Construction Type, Governing
Codes, Index of Drawings, and any other information that relates to Mechanical or
Plumbing work.
5 Check for consistent appearance of Title Blocks, Drawing Scales, North Arrows,
Professional Stamps, Company Logos, Sheet Numbers, Sheet Titles, Issue Dates, and
Issue Revisions on all sheets.
Demolition Plans
1 Verify that Demolition Symbols (cross-hatching, etc.) are clear and complete, and are
coordinated with other disciplines.
2 Verify there are notes regarding potential hazardous materials (asbestos, lead paint,
etc.), and coordinate with Architect or other Prime Consultant and Owner.

Copyright 2008 HVAC Design Solutions

Extensive Quality
Control Plumbing
Checklists are available
in a separate Plumbing
Peer Review Software
Package

Over (70) Pages of


Checklists and
Spreadsheets for a
thorough review of
Plumbing Construction
Documents
22

Return to Table of Contents


Plumbing Underground Floor Plan
1 Read all Sheet Notes and verify they are clear and appropriate.
2 Verify all References are correct. Follow references to indicated sheets.
3 Coordinate Plumbing Underground Plan with Structural Grade Plan. Verify that
below-slab Footings and Grade Beams have been shown on the Plumbing
Underground Floor Plan, for underground pipe coordination. (If Footings and Grade
Beams are not on Plumbing Underground Plan, they should be added to the
background).
4 Verify that any pipes passing over, under, or through Footings or Grade Beams have
been coordinated with Structural Plans. Check on provisions for sleeving beams, etc.
(Click on hyperlink to jump to the sheet checklist)
Verify depth of Footings and Grade Beams below floor slab, to check for any
potential conflicts.
Preliminary Review of Plans and Specifications
5
Verify that Footings and Grade Beams are not directly below Plumbing Fixture
Legend and Symbols, and Fixture Calculations Sheet
outlets, Floor Drains, Floor Sinks, Plumbing Chases, or pipe drops, such as Storm
Schedule Sheets
Drains and Overflow Drains. Verify coordination with pipes at Columns, such as
Plumbing Site Plan
Sanitary Vents and Trap Primer water pipes, to avoid conflicts with Footings at
Plumbing Demolition Plans
Columns.
Plumbing Underground Floor Plan
6
Check for locations of building expansion joints or seismic joints, and verify that pipes
Plumbing Floor Plans
have been designed to accommodate expansion joints.
Plumbing Roof Plans
7
Follow all Waste Pipe risers up to floors above. Place a pencil check-mark on each
Plumbing Medical/Lab/Process Piping Plans
riser as it is verified to continue on the floor above (or roof). Check for coordinated
Central Plant Plumbing Plans
locations from floor to floor on each pipe riser.
Plumbing Riser Diagram Sheets
8
After following each Waste pipe riser to the top, follow horizontally to the most remote
Plumbing Detail Drawings
fixture or drain connection point. Pencil in Fixture Units (FU) for all Fixtures and
Drains served by each Waste riser. Sum the flow rates (FU) from the remote fixtures
or drains, back to the risers. Pencil in the accumulated FU on the plans adjacent to
the pipes. Verify that Fixture Units are listed for all fixtures or drains and that
Schedules for each fixture are complete.
9 If the Floor Plan has references to larger scale plans (such as Enlarged Toilet Room
Partial Plans), follow to the referenced Enlarged Plan. Verify all pipe sizes are
coordinated from Floor Plan to Enlarged Partial Plan. Verify the Floor Plan and
Enlarged Plan have the same background and are current with the latest
Architectural plans. Pencil in the Fixture Unit value for each Fixture or Drain on the
Enlarged Plan, and sum the FU to the extent of the Enlarged Scale Plan. Transfer
the total flow rates back to the original Floor Plan, for continuation.
C

Plumbing Plan Review Items


Contents:
A
B
C
D
E
F
G
H
I
J
K
L

Example of Quality
Control Check List
Items

Copyright 2008 HVAC Design Solutions

23

WATER PIPE SIZING CALCULATIONS


PROJECT NAME:

FLUSH VALVES = 1, FLUSH TANKS = 2

PROJECT NUMBER:
DATE:

AVAILABLE WATER PRESSURE CALCULATIONS

PIPE SIZE SCHEDULE (@ MAX. ALLOWABLE PD/100 FT)


SIZE

MAX. GPM

VEL.

DEMAND FLOW RATE (GPM)

96

1/2

1.4

WATER MAIN PRESSURE (PSIG)

100

3/4

3.2

11

3.9

80

1 1/4

24

5.2

1 1/2

32

5.6

67

6.2

PRESSURE DROP THRU METER (PSIG)


PRESSURE REDUCING VALVE - PRESSURE (IF REQUIRED)
PRESSURE DROP THRU BACKFLOW PREVENTER (PSIG)
STATIC HEIGHT OF HIGHEST FIXTURE ABOVE MAIN (FT)

30

PRESSURE DROP THROUGH WATER TREATMENT (PSIG)

10

2 1/2

110

7.0

RESIDUAL PRESSURE REQUIRED AT LAST OUTLET (PSIG)

25

180

6.5

PRESSURE AVAILABLE FOR PIPING LOSS (PSIG)

27

300

8.0

460

6.8

PRESSURE BOOSTER PUMP (IF REQUIRED) (PSIG)

13

After completing input and


calculations, Output and
Sizing Documents can be
printed for submittal to
building department
officials and for addition to
drawings and schedules

TOTAL DEVELOPED LENGTH OF LONGEST PIPE RUN (FT)

600

700

8.0

MAXIMUM ALLOWABLE PIPE PRESS. DROP (PSIG/100 FT)

4.5

1200

8.2

Copyright 2008 HVAC Design Solutions

24

WATER PIPE SIZING SCHEDULE

FIXTURE UNIT CALCULATIONS


WATER-SCHED2

FU-CALCS

WATER PIPE SIZING CALCULATIONS


PIPESIZE

WASTE AND VENT PIPE SIZING


W&V SIZES

WASTE PIPE SIZING SCHEDULE


WASTE-SCHED

VENT PIPE SIZING SCHEDULE


VENT-SCHED

ROOFDR

ROOF DRAINS, VERTICAL AND HORIZONTAL


PIPE SIZING

MEDGAS

MEDICAL GAS PIPING CALCULATIONS PRELIMINARY

STORMPIPE-SCHED

WATER FIXTURE UNIT TO GPM CONVERSION

WATERHTR-CALCS

ROOFDR-SCHED

ROOF DRAIN, LEADER, OR VERTICAL PIPE


SCHEDULE

HORIZONTAL ROOF DRAINAGE PIPING SCHEDULE

WATER HEATER SIZING CALCULATIONS

FU-GPM

AIR COMPRESSOR CALCULATIONS

GAS-SCHED1

NATURAL GAS PIPE SIZING SCHEDULE - LOW


PRESSURE (BELOW 1.5 PSI)

GAS-SCHED2

NATURAL GAS PIPE SIZING SCHEDULE MEDIUM PRESSURE (ABOVE 1.5 PSI)

AIRCOMP

Extensive Plumbing Programs

GAS PIPE SIZING DIAGRAM


GASPIPE-DIAG.

Copyright 2008 HVAC Design Solutions

25

Straightforward takeoff and input allows


easy calculation and sizing of Plumbing
Systems.
Extensive procedures, formulas, charts,
and tables as prescribed by Plumbing
Codes and as recommended by ASPE and
ASHRAE have been included and have been
used to establish the Accurate Plumbing
System Sizes.
Multiple Programs are included, covering
most of the typical Plumbing Design Tasks for
most projects.
Copyright 2008 HVAC Design Solutions

26

Significantly reduces Reference


Material Dependence which can save a
great deal of time and effort.
Output in the form of Compliance
Documents or System Sizing
Summaries for submittal to appropriate
code enforcement officials or building
departments.
Extensive Help Files that are
hyperlinked to each program, form, or table.
Copyright 2008 HVAC Design Solutions

27

Limited time Special Pricing available at


our website
www.hvacdesignsolutions.com
Plumbing Design Package
Original Price: $250 US, Special Price:
$189 US
Plumbing Peer Review Package
Original Price: $200 US, Special Price:
$148 US

Copyright 2008 HVAC Design Solutions

28

Current Version: 2.16, with latest update


(03/31/2008) Free updates, as available.
To purchase Plumbing Design or Plumbing
Peer Review, visit our website at
www.hvacdesignsolutions.com and go to
the Prices/Orders page
Software can be downloaded for
immediate installation (with password)
after purchase is confirmed

Copyright 2008 HVAC Design Solutions

29

OS: Windows 98, 2000, XP, 2003, Vista


Processor: Pentium or equivalent
Ram: 512MB (minimum recommended)
Disk Space: 100 MB (recommended)
Software: MS Word, MS Excel

Copyright 2008 HVAC Design Solutions

30

Thank you for taking your time to


review our Plumbing Design software
packages
If you have any questions or
comments, you can e-mail to:
steveathvacdesignsolutions.com , or
supportathvacdesignsolutions.com
We also have an interactive demo of
our Plumbing Design software that can
be delivered, on request, via e-mail.
Copyright 2008 HVAC Design Solutions

31