You are on page 1of 4

1612 Hutton Drive, Suite 140 Carrollton, Texas 75006

Phone: (800) 558-6960 Fax: (972) 389-4752

KELLEY
CM MECHANICAL DOCKLEVELER PIT DETAILS
TRUK STOP CONDUIT RUN DETAILS (Back Cover)

CUSTOMER
ADDRESS
JOB

DOCKLEVELER: MECHANICAL Model Number

QUANTITY

DOCKLEVELER RATING PER ANSI MH14.1-1987:


30K
35K

40K

LIP LENGTH:

20"

TRUK STOPS:

16"
STAR 1
STAR 2

18"
STAR 4

45K

TRUK ALERT

NOTE: All TRUK STOPS, except STAR 1, require 115V, 1.

CERTIFIED FOR CONSTRUCTION


BY

DATE

COMPANY
CITY & STATE
5559 R4 MAY 2006

Death or serious injury could result from failure to follow Kelley


specifications for pit dimensions and/or configurations, or conduit
location; improper installation of dock leveler, anchoring devices
or optional/accessory equipment; installation into improperly formulated, prepared or placed concrete or concrete which is otherwise inadequate or unsound.
1

CM DOCKLEVELER PIT DETAILS

90

90

C
G
CL PIT

F
D

90

B
3

3/4" DIA. ANCHOR BOLT,


FIELD INSTALLED
SUPPLIED BY OTHERS

DOCK
HEIGHT

8-3/4

3/8" SIDE OF
PIT TO SIDE OF
BUMPER
MOUNTING
PLATE
1/4"

SEE NOTE 1
BUMPER
MOUNTING
ANGLE

2 LAMINATED BUMPERS
FURNISHED BY
KELLEY COMPANY, INC.

5559 R4 MAY 2006

34

NOTE 1: IF A STAR TRUK STOP IS TO BE INSTALLED AND THE


DRIVEWAY IS SUSCEPTIBLE TO FROST, PLACE A
STYROFOAM BLOCK IN THE CONCRETE IN THIS AREA. THIS
WILL PREVENT DAMAGE TO THE STAR TRUK STOP WHEN
DRIVEWAY RISES.

LOCATION FOR SINGLE CONTROL BOX


FOR STAR TRUK STOP
CONTROL
BOX

48"

ANCHOR LAYOUT FOR CURB ANGLE

3"

12"

12"

12"

3"

3"
3"
1/4"

CONCRETE ANCHORS, 1/2" DIA., 6" LONG, LOCATED AS SHOWN

CM DOCKLEVELER PIT DIMENSIONS

NOM. DOCKLEVELER SIZE

6' x 6'

6' x 8'

6' x 10'

6.5' x 6'

6.5' x 8'

6.5' x 10'

7' x 6'

7' x 8

7' x 10'

PIT LENGTH

DIM. "A"

63"

87"

111"

63"

87"

111"

63"

87"

111"

PIT WIDTH

DIM. "B"

73"

73"

73"

79"

79"

79"

85"

85"

85"

DIM. "C"

19-1/2"

19-1/2"

23-1/2"

19-1/2"

19-1/2"

23-1/2"

19-1/2"

19-1/2"

23-1/2"

DIM. "D"

20"

20"

24"

20"

20"

24"

20"

20"

24"

DIM. "E"

79"

79"

79"

85"

85"

85"

91"

91"

91"

DIM. "F"

60"

84"

108"

60"

84"

108"

60"

84"

108"

DIM. "G"

21"

21"

21"

21"

21"

21"

21"

21"

21"

DIM. "H"

17"

17"

21"

17"

17"

21"

17"

17"

21"

PIT DEPTH
Rear
PIT DEPTH
Front
CURB ANGLE
Front & Rear
CURB ANGLE
Side
CURB ANGLE
Bumper
CURB ANGLE
Bumper

5559 R4 MAY 2006

TRUK STOP CONDUIT RUN LOCATION DETAILS


THROUGH WALL TO BOX
FOR SIGNAL LIGHT
1/2" CONDUIT

NOTE: ALL MOTOR POWER WIRES OR OTHER


HIGH VOLTAGE WIRES SHOULD BE RUN IN A
SEPARATE CONDUIT FROM ALL LOW VOLTAGE
CONTROL CIRCUIT WIRING.

4"

TO POWER
SUPPLY
1/2" CONDUIT

19-3/4
9-3/4

CONTROL
BOX

NOTE: SIGNAL LIGHT MUST BE


ON TRUCK DRIVERS SIDE
OF DOOR OPENING.

15"

3/4 CONDUIT (NOT REQUIRED FOR


STAR 1 OR TRUK ALERT) EXIT
CONDUIT INSIDE BUILDING NEAR
WALL UNDER CONTROL BOX.

43"

C
L Dockleveler Pit

ADDITIONAL CONDUIT REQUIREMENTS FOR STAR 4


EXIT CONDUIT INSIDE BUILDING NEAR
WALL UNDER CONTROL BOX.

16"

14"

FOR HYDRAULIC HOSES USE


2" CONDUIT (DRAIN WASTE
OR VENT PVC PIPE WITH 45
LONG SWEEP ELBOW)

1/2" CONDUIT
STAR 4, (ONLY IF
USED WITH LIP LIMIT
SWITCH)

15"
41"
42"

C
L

3" EXIT CONDUIT AT ANGLE TO DOCK

Dockleveler Pit

1612 Hutton Drive, Suite 140 Carrollton, Texas 75006


Phone: (800) 558-6960 Fax: (972) 389-4752

5559 R4 MAY 2006

FACE 3" ABOVE DRIVE