You are on page 1of 16

CBA-Series Scotch-Yoke Pneumatic Actuators

Compact, Lightweight and Economical

PED 97/23/EC Compliant

Xylan Coated Cylinder

Water Ingress Protected


IP66 and IP67M

Low Maintenance

Economical

Jackscrew Option

Five-Year Warranty

Dual Mounting Interface

Suitable for SIL 2 or SIL 3

Bi-directional Travel Adjustment

12
6
10

CBA-SERIES PNEUMATIC
DESIGN AND CONSTRUCTION

Mechanical Components
The Bettis CBA-Series pneumatic actuators are
compact, lightweight and ideally suited for automating
ball, butterfly and non-lubricated plug valves, or any
quarter-turn (90 degree) rotating mechanism. These
economical, low maintenance actuators provide a
reliable means of automating your valve. Available
with optional features and controls to meet your most
demanding automation needs. The CBA-Series, available
in double-acting and spring-return models, are independently certified to BS 5490: 1977 - IP66 and IP67M
for water ingress protection.

Operating Ranges
Double-acting CBA-Series actuators are available with
guaranteed minimum torque outputs to 11,515 lb-in
(1,301 Nm).
The CBA-Series spring-return models require pressure
in only one direction of travel and are suitable for fail
clockwise or counterclockwise applications without
modification. These models produce guaranteed spring
ending torques to 4,269 lb-in (482 Nm).
Standard construction CBA-Series actuators are
designed for operating temperatures of -20F to +200F
(-29C to +93C). High temperature trim allows continuous
operation from 0F to +350F (-18C to +177C).
Additionally, special non-PED low temperature trim
allows operation to -40F (-40C). Consult factory when

temperature requirements exceed these limits.


Operating pressures for the CBA-Series range from 40
to 150 PSIG (3 to 10 BAR).

Design Features
Water Ingress Protection The CBAs meet both IP66
and IP67M specifications for submergence and severe
high pressure water deluge test, offering superior water
ingress protection and corrosion resistance. The actuator
has no gaskets and is totally o-ring sealed.
1) New, Outer Lip-Type Torque Shaft Seals restrict
external contaminants, providing a high level of
corrosion and water-resistance.
2) New O-Ring Sealed Cylinders essentially eliminate
the possibility of any cylinder leakage throughout
the full range of operating and climatic conditions.
3) Standard Accessory Mounting Pad The new
accessory mounting pad is standard and identical
on all CBA and CBA-300 Series models, allowing the
panel mounting of controls.
4) Dual Valve Mounting Interface allows the flexibility
to change the actuator fail mode, without disassembly, by simply inverting the actuator. They may be
installed in any position; parallel or at right angles to
the flow line, in the vertical or the horizontal plane.

5
8

3
1
9

Model M3 Jackscrew shown (M3HW with optional


handwheel not pictured).

13

7) New Piston Heel and Yoke Pin Bearings


The CBA features PTFE/bronze bearings
11
on the actuators piston heel and yoke
pin. These bearings help to assure smooth
and consistent torque output, while
enhancing total cycle life.
8) Ductile Iron Housing CBA actuator
housings are made of pressure vessel quality ductile iron
which is approved for use by ASME and the Pressure
Equipment Directive (PED 97/23/EC). All housings have
been optimized by finite element analysis and are
designed for light weight while retaining maximum
strength, ductility and corrosion resistance.

5) Jackscrew Option A blowout-proof economical


jackscrew manual override is available as an option
to the CBA models (see inset above). The jackscrew
also acts as a stop adjustment screw.
This feature has several advantages:

Produces full rated torque output in the event of air


supply loss.

During normal power operation, the manual override


has no affect on actuator torque output or operating
speed.

Double-acting actuator models are available with one


or two jackscrews.

6) XylanTM Cylinder Coating, the standard internal


coating on all CBA-Series actuators. This fluoropolymer coating is highly resistant to abrasion, thermal
shock and provides excellent lubricity and low friction
properties. Corrosive salts and other chemicals
normally found in the atmosphere or instrument
air supply system will not adversely affect
its performance. XylanTM bonds to the chemically
prepared surface of the steel cylinder so effectively
that, unlike other coatings, cracking and flaking are
virtually eliminated.

9) The Scotch-Yoke Mechanism transforms linear


movement of the piston into a 90 degree rotation,
providing optimum torque curves, ideal for most
quarter-turn valve applications.
10) Center Bar, made of improved high strength alloy
steel, guides the piston throughout its full stroke,
preventing metal to metal contact with
the cylinder bore.
11) Bi-directional Travel Stops are an
integral part of the actuator allowing 80
to 100 total travel adjustment. Extended
travel stops are optional. This feature
provides an unmatched travel range to
assist in prolonging valve seat integrity.
12) SpringsHigh-strength, high-performance
alloy carbon steel springs are protected by Tactyl
50, a pliable self-healing coating. Bettis takes and
additional step and shot peens the springs, helping
to extend the actuators spring cycle life.
13) Yoke Arm Bearing Washer Acetal bearings
positively prevent metal-to-metal contact, helping
to assure smooth and consistent torque output.

SIZING AND SELECTION


General Definitions

Actuator Selection Procedures

To clarify and standardize terminology, Bettis offers the


following definitions for terms commonly used. Please become
familiar with and use the following standard definitions when
referring to Bettis quarter-turn actuators.

A) Determine the type of Bettis actuator required: double-acting


or spring-return.

Quarter-turn: A device which rotates a minimum of 90 degrees.


All Bettis quarter-turn actuators will rotate more than 90 degrees.

C) Using this information, select the applicable torque rating


table and see the appropriate following examples.

Position: That degree of rotation describing an actuators


current location. The mid position of a quarter-turn actuator
is generally at forty-five (45) degrees.

Scotch-Yoke, Double-Acting Actuators (example


assumes CW to close)

CW: Clockwise rotation.


CCW: Counterclockwise rotation.
Stroke: A continuous, ninety (90) degree rotation of a quarter-turn
actuator. Bettis spring-return actuators have two (2) different
strokes, a pressure stroke and a spring stroke. Bettis doubleacting actuators have two (2) pressure strokes. Note that rack
and pinon actuators have common torque valves for both pressure
strokes, while scotch yoke actuators have different torque values
depending on which side of the piston is doing the work.
Cycle: The collective reference to two (2) strokes, one (1) for
clockwise (CW) rotation and one (1) for counterclockwise (CCW)
rotation. Bettis actuators must rotate through two (2) stroke to
complete one (1) cycle.
Safety Factor: Represents a protective component (an adjustment
to torque requirement) sometimes added to a valves required
torque value. Often used when the user/specifier is not certain of
the valves torque requirements, or because of other application
concerns.

Sizing Bettis Actuators


The following information is generally the minimum required
for sizing Bettis quarter-turn pneumatic and hydraulic actuators
for specific valve requirements.
A) An accurate maximum torque requirement must be obtained
before actuator sizing begins. Normal maximum stem torque for
a properly applied and maintained valve is usually defined as:
The maximum starting torque required to rotate the valve element
(ball, disc, plug, etc.) from a fully closed position (unsealing),
against the maximum normal valve rated different pressures.
Most valve manufacturers make adjustments in the form of
torque amendments under various operating conditions.
Application operating conditions such as temperature extremes,
actual differential pressure, unusual loading, high flow rates,
operating speeds, etc. are some of the most common causes
for adjustments.
Bettis recommends that the valve manufacturer supply the
maximum required torque value(s) (including any adjustments or
suggested safety factors). Additionally, the valve manufacturer
must identify at which position(s) and direction(s) of rotation
(CCW or CW) these maximum requirements occur.
B) Bettis actuators include stops which will resist the maximum
rated torque output of the actuator. The possibility exists, that
should the valve become immobilized during rotation, the
actuator could exceed the maximum allowable valve input
torque rating. If this possibility is a concern, your application
needs further review.
Once the maximum torque requirements, its position, and
direction of rotation are identified, the appropriate Bettis actuator
can be selected from torque output charts on pages 47.
4

B) Determine the power supply media: pneumatic or hydraulic,


and the minimum/maximum supply pressure(s) at the actuator.

Note: The valves torque requirements must be exceeded by


the actuators torque output at all corresponding positions and
directions of rotation.
Bettis has included Start, Minimum, and End pressure torque
outputs for your use.
A) Using your minimum operating pressure, select an operating
pressure column from the Pressure Torque Rating Section of less
than or equal pressure. Move down the column until both starting
and minimum output torques are found which exceed the valves
maximum and minimum torque requirements. Determine the
Bettis model number at the left, under the model number column.
B) Once a Bettis actuator model has been selected, use the
performance data tables to ensure your maximum supply pressure
does not exceed the maximum operating pressure (M.O.P.) for
your Bettis actuator. If the actuator selected is not rated for your
maximum supply pressure, either the maximum supply pressure
must be reduced or an actuator rated for a higher M.O.P. must
be selected.

Scotch-Yoke, Spring-Return, Fail CLOCKWISE Actuators


(example assumes CW to close)
Note: The valves maximum torque requirements must be
exceeded by the actuators torque output at all corresponding
positions and directions of rotation.
Bettis has included Start, Minimum, and End Spring Torque
outputs, as well as Start, Minimum and End Pressure Torque
Outputs for your use. The minimum torque outputs listed on the
Spring-Return torque charts are the lowest value of torque output
available at any position, during either stroke (pressure or spring).
A) Select from the Spring Torque column a Spring Ending torque
output which exceeds that of the valves maximum seating
requirement.
B) Proceed to the right using your minimum operating pressure
and select an operating pressure column from the Pressure
Torque Rating Section of less than or equal pressure. The Pressure
Start torque output must exceed the valves torque requirement
at this position (unseating). The Pressure End torque output must
exceed the valves torque requirement at this position (full flow)
and direction of rotation (CCW).
C) Once a Bettis actuator model has been selected, use the
performance data tables to ensure your maximum supply pressure
does not exceed the maximum operating pressure (M.O.P.) for
your Bettis actuator. If the actuator selected is not rated for your
maximum supply pressure, either the maximum supply pressure
must be reduced or an actuator rated for a higher M.O.P. must
be selected.
Contact your local Authorized Bettis distributor or a Bettis
manufacturing facility if you require assistance.

Performance Data CBA-Series (Pneumatic) Imperial & metric


Double-Acting Actuators
CBA-Series
Volumes
Actuator
Model

CBA 315
CBA 420
CBA 520
CBA 525
CBA 725

Outboard

Inboard
(Housing)

Maximum Operating
Pressure
(MOP)*

Maximum Allowable
Working Pressure
(MAWP)**

Approximate Weight
of Actuator
(MAWP)**

Cu. Inches

Cubic CM

Cu. Inches

Cubic CM

PSIG

Bar

PSIG

Bar

Lbs.

KG

24
53
83
105
208

393.3
868.5
1360.1
1720.6
3408.5

54
115
148
207
327

885.0
1884.5
2425.3
3392.1
5358.6

120
120
70
120
80

8.3
8.3
4.8
8.3
5.5

200
200
160
200
160

13.8
13.8
11.0
13.8
11.0

20
22
28
44
68

9.1
10.0
12.7
20.0
31.0

Spring-Return Actuators
CBA-Series
Actuator
Model

Cu. Inches
CBA 315- SR40
SR60
SR80
SR100
CBA 415- SR40
SR60
SR80
SR100
CBA 420- SR40
SR60
SR80
SR100
CBA 520- SR40
SR60
SR80
SR100
CBA 525- SR40
SR60
SR80
SR100
CBA 725- SR40
SR60
SR80
SR100

Maximum Operating
Pressure
(MOP)*

Volume

54
54
54
54
75
75
75
75
115
115
115
115
148
148
148
148
207
207
207
207
327
327
327
327

Cubic CM
885
885
885
885
1229
1229
1229
1229
1884.5
1884.5
1884.5
1884.5
2425.3
2425.3
2425.3
2425.3
3392
3392
3392
3392
5358.6
5358.6
5358.6
5358.6

PSIG
155
152
150
164
100
112
117
114
157
156
161
166
110
116
120
132
146
151
159
163
102
115
124
124

Bar
10.7
10.5
10.3
11.3
6.9
7.7
8.1
7.9
10.8
10.8
11.0
11.4
7.6
8.0
8.3
9.1
10.1
10.4
11.0
11.2
7.0
8.0
8.6
8.6

Maximum Allowable
Working Pressure
(MAWP)**
PSIG

Bar

200
200
200
200
160
160
160
160
200
200
200
200
160
160
160
160
200
200
200
200
160
160
160
160

13.8
13.8
13.8
13.8
11.0
11.0
11.0
11.0
13.8
13.8
13.8
13.8
11.0
11.0
11.0
11.0
13.8
13.8
13.8
13.8
11.0
11.0
11.0
11.0

Approximate Weight
of Actuator
Lbs.
22
23
26
25
27
29
30
31
37
39
40
41
45
48
49
53
62
65
65
67
97
98
104
107

KG
10.0
10.4
11.8
11.4
12.7
14.1
14.1
14.1
16.8
17.7
18.1
18.6
20.4
21.8
22.2
24.0
28.1
29.5
29.5
30.4
44.0
44.5
47.2
48.5

Notes:

CBA-SRXXM mechanical handwheel overrides are available on these models. The override adds approximately 2 lbs. (.8 kg) to the weight of the
standard CBA model.

Maximum volume including cavity required for calculating consumption per stroke.

Maximum Operating Pressure (MOP) is the pressure required to produce the maximum rated torque of the actuator.

**

Maximum Allowable Working Pressure (MAWP) is the


maximum static pressure that may be applied to a fully
stroked actuator against the travel stops.
Standard installation produces clockwise rotation
when the outboard side of piston is pressurized.
Standard installation produces counterclockwise
rotation when the inboard side of piston is pressurized.
Note: Actuator may be installed opposite of that
shown above.

Torque Ratings CBA-Series (Pneumatic) Imperial


All Published Torques are Typical Minimum Values.

Double-Acting Actuators
CBA-Series
Actuator
Model
CBA 315
CBA 420
CBA 520
CBA 525
CBA 725

See Bettis
Definitions
Start/End
Minimum
Start/End
Minimum
Start/End
Minimum
Start/End
Minimum
Start/End
Minimum

40

50

678
404
1536
871
2133
1302
2944
1720
5757
3434

848
505
1921
1089
2666
1628
3680
2150
7197
4292

Operating Pressure (PSIG)


60
70
80
90
Pressure Torque Output Start/Min./End (lb-in)
1017
606
2305
1307
3200
1954
4416
2580
8636
5151

1187
707
2689
1525
3733
2279
5152
3009
10075
6009

100

120

1356
808
3073
1743

1526
910
3457
1961

1695
1011
3841
2179

2034
1213
4609
2614

5888
3439
11515
6868

6624
3869

7361
4299

8833
5159

Notes:
Start: (starting) That torque output position at which an actuator produces its greatest torque output. The starting torque outputs listed in Bettis
scotch-yoke torque output charts are the lesser of the two (2) pressure strokes, when there is a difference (different areas).
Minimum: (min.) That torque output, at an intermediate position, at which an actuator produces its lowest torque output. The minimum torque
outputs shown on Bettis pressure torque output charts are the lowest torque values produced during the pressure stroke(s). For double-acting actuators, this is also the mid position.
End: (ending) That torque output position at which an actuator has reached the limit of a pressure stroke. For double-acting actuators the end torque
output is equal to the start torque output.

Spring-Return Actuators
CBA-Series
Actuator
Model
CBA315 SR40

CBA315 SR60

CBA315 SR80

CBA315 SR100

CBA415 SR40

CBA415 SR60

CBA415 SR80

CBA415 SR100

Spring Torque
Start/Min./End
(lb-in)
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End

350
151
202
598
238
305
757
306
402
1069
405
494
682
284
365
1076
431
577
1345
576
711
1659
673
756

40

50

Operating Pressure (PSIG)


60
70
80
90
Pressure Torque Output Start/Min./End (lb-in)

375
158
216

531
247
377
438
153
172

688
336
538
608
249
342

844
424
698
778
343
512
698
237
312

1000
512
859
948
436
681
884
328
498

692
285
387

981
451
701
701
264
294

1271
614
1014
979
435
600

1560
778
1328
1256
603
905
1077
428
510

1850
941
1641
1533
770
1211
1362
602
811

1157
600
1020
1117
530
851
1069
418
683
876
331
421
2139
1105
1955
1811
934
1516
1648
772
1113
1701
542
564

100

120

150

1313
688
1181
1287
623
1021
1254
509
869
1053
428
600
2429
1268
2269
2088
1099
1822
1933
942
1414
2007
719
861

1626
864
1502
1627
808
1360
1625
689
1239
1406
621
957

2095
1128
1985
2136
1085
1870
2181
958
1795
1935
906
1493

Torque Ratings CBA-Series (Pneumatic) Imperial


All Published Torques are Typical Minimum Values.

Spring-Return Actuators
CBA-Series (continued)
Actuator
Model
CBA420 SR40

CBA420 SR60

CBA420 SR80

CBA420 SR100

CBA520 SR40

CBA520 SR60

CBA520 SR80

CBA520 SR100

CBA525 SR40

CBA525 SR60

CBA525 SR80

CBA525 SR100

CBA725 SR40

CBA725 SR60

CBA725 SR80

CBA725 SR100

Spring Torque
Start/Min./End
(lb-in)
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End

591
301
479
1320
481
691
1661
655
901
2230
836
1119
1004
445
562
1719
747
966
2575
1019
1243
3880
1361
1715
1652
608
949
2527
983
1372
3038
1293
1680
4620
1676
2234
3148
1283
1641
5249
2106
2762
7370
2830
3330
9482
3260
4269

Operating Pressure (PSIG)


60
70
80
90
Pressure Torque Output Start/Min./End (lb-in)

40

50

844
317
391

1173
500
709

1501
680
1028
1333
480
562

1829
859
1346
1685
670
871
1468
481
502

2157
1037
1665
2037
860
1179
1825
690
844

1311
503
677

1805
782
1255
1385
484
509

2300
1056
1834
1895
794
1087

2794
1326
2412
2405
1095
1665
2133
790
893

3289
1596
2990
2914
1390
2243
2658
1111
1494

1619
638
946

3354
1306
1948

2310
993
1637
1849
632
694

3001
1345
2328
2549
1035
1404

3692
1698
3019
3250
1425
2114
2732
966
1130

4383
2050
3710
3950
1814
2824
3432
1363
1859

4780
2048
3488
3467
1234
1284

6206
2788
5028
4817
2080
2824

7632
3520
6568
6167
2897
4364
5064
2018
2326

9058
4252
8108
7517
3709
5904
6395
2872
3885

2485
1215
1983
2390
1048
1488
2182
891
1187
1958
643
674
3783
1867
3568
3424
1685
2821
3183
1424
2095
2535
855
913
5074
2402
4401
4651
2198
3534
4133
1750
2589
3673
1369
1696
10484
4984
9648
8867
4511
7444
7726
3706
5444
7374
2478
2748

100

120

150

2813
1393
2302
2742
1235
1797
2539
1088
1529
2320
857
1021
4278
2137
4146
3934
1980
3399
3708
1734
2696
3067
1171
1491
5765
2752
5092
5351
2582
4244
4833
2138
3318
4392
1777
2454
11910
5716
11189
10217
5313
8984
9057
4541
7003
8781
3279
4250

3470
1748
2939
3446
1607
2415
3253
1480
2215
3044
1264
1716

4454
2282
3894
4503
2166
3341
4325
2068
3243
4130
1859
2758

4757
2347
3898
4132
1773
2647
7147
3452
6474
6752
3348
5665
6234
2900
4777
5832
2581
3970

8854
4499
7795
8336
4042
6965
7991
3770
6245

11719
6189
10122
11595
4828
7254

Notes: Spring-return, quarter-turn actuators use pressure and springs(s) to produce torque.
Start: (starting) That torque output position at which a spring-return actuator produces its greatest torque output during a spring stroke. The starting
torque output listed in Bettis spring-return torque output charts is that torque output position, where the spring is fully compressed, and capable of
transferring its maximum force.
Minimum: (min.) That torque output, at an intermediate position, at which an actuator produces its lowest torque output. The minimum torque
outputs listed on the Bettis spring torque output charts are the lowest value of torque output produced at any position, during either stroke (pressure or
spring).
End: (ending) That torque output position, at which an actuator has reached the limit of the spring stroke. The spring ending torque output values listed
on Bettis spring-return torque output charts is the torque output value where the spring is fully extended and is transferring its lowest force value.

Torque Ratings CBA-Series (Pneumatic) metric


All Published Torques are Typical Minimum Values.

Double-Acting Actuators
CBA-Series
Actuator
Model
CBA315
CBA420
CBA520
CBA525
CBA725

See Bettis
Definitions
Start/End
Minimum
Start/End
Minimum
Start/End
Minimum
Start/End
Minimum
Start/End
Minimum

3.5

83
50
189
107
262
160
362
211
708
422

97
58
220
125
306
187
422
247
826
492

Operating Pressure (Bar)


4
5
5.5
6
Pressure Torque Output Start/Min./End (Nm)
111
66
252
143
350
213
482
282
944
563

139
83
315
179
437
267
603
352
1179
703

153
91
346
196

167
99
378
214

194
116
441
250

222
133
504
286

663
387
1297
774

724
423

844
493

965
564

Notes:
Start: (starting) That torque output position at which an actuator produces its greatest torque output. The starting torque outputs listed in Bettis
scotch-yoke torque output charts are the lesser of the two (2) pressure strokes, when there is a difference (different areas).
Minimum: (min.) That torque output, at an intermediate position, at which an actuator produces its lowest torque output. The minimum torque
outputs shown on Bettis pressure torque output charts are the lowest torque values produced during the pressure stroke(s). For double-acting actuators, this is also the mid position.
End: (ending) That torque output position at which an actuator has reached the limit of a pressure stroke. For double-acting actuators the end torque
output is equal to the start torque output.

Spring-Return Actuators
CBA-Series
Actuator
Model
CBA315-SR40

CBA315-SR60

CBA315-SR80

CBA315-SR100

CBA415-SR40

CBA415-SR60

CBA415-SR80

CBA415-SR100

Spring Torque
Start/Min/End
(Nm)
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End

39
17
23
68
27
34
86
35
45
121
46
56
77
32
41
122
49
65
152
65
80
187
76
85

Operating Pressure (Bar)


3
49
21
31

90
39
56

3.5
61
29
44
51
18
21

113
52
82
82
31
36

4
5
5.5
6
7
Pressure Torque Output Start/Min./End (Nm)
74
100
113
125
151
36
51
58
65
79
57
84
97
110
136
65
93
107
121
148
26
41
49
57
72
35
63
76
90
118
84
99
115
145
29
37
44
59
41
56
71
101
93
122
34
50
42
71
137
185
208
232
279
66
93
106
119
146
108
159
185
210
262
104
150
173
195
241
45
73
87
100
127
61
111
136
161
211
130
153
176
223
53
68
82
109
66
91
116
165
182
232
54
84
54
102

10

11

177
94
162
176
87
146
175
74
132
151
66
100

202
108
189
204
102
174
206
89
162
180
81
129

228
123
215
232
117
202
236
103
192
209
97
159

238
113
188

270
137
214

Torque Ratings CBA-Series (Pneumatic) metric


All Published Torques are Typical Minimum Values.

Spring-Return Actuators
CBA-Series (continued)
Actuator
Model
CBA420-SR40

CBA420-SR60

CBA420-SR80

CBA420-SR100

CBA520-SR40

CBA520-SR60

CBA520-SR80

CBA520-SR100

CBA525-SR40

CBA525-SR60

CBA525-SR80

CBA525-SR100

CBA725-SR40

CBA725-SR60

CBA725-SR80

CBA725-SR100

Spring Torque
Start/Min/End
(Nm)
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End
Start
Min.
End

67
34
54
149
54
78
188
74
102
252
94
126
113
50
64
194
84
109
291
115
140
438
154
194
187
69
107
286
111
155
343
146
190
522
189
252
356
145
185
593
238
312
833
320
376
1071
368
482

Operating Pressure (Bar)


3

3.5

108
43
57

135
58
83

168
68
99

210
86
134

436
175
281

208
91
147
161
58
62

267
115
191
215
75
85

552
236
407
403
147
158

4
5
5.5
6
7
Pressure Torque Output Start/Min./End (Nm)
162
216
243
270
324
73
102
117
131
160
109
161
187
213
266
143
200
229
258
316
50
81
97
112
143
56
107
132
158
208
176
205
235
293
61
77
94
126
66
94
123
179
209
268
64
100
64
121
249
330
370
411
492
113
158
180
202
246
194
289
336
384
478
203
286
328
370
453
83
132
156
180
229
110
205
252
299
394
256
299
342
428
98
125
150
201
118
167
216
315
268
356
84
138
84
178
324
437
493
550
663
144
202
231
260
317
248
361
417
474
587
272
387
445
502
617
108
172
204
235
298
143
259
317
375
492
329
386
443
558
121
153
185
248
148
208
268
387
391
509
141
208
166
290
669
903
1020
1137
1370
297
419
479
539
658
534
786
912
1038
1291
514
735
846
956
1178
217
351
417
483
614
284
537
663
789
1042
610
719
828
1046
253
322
391
527
307
435
563
818
786
1016
251
384
260
506

10

11

377
190
318
374
173
259
352
158
235
328
134
178

431
219
370
431
204
310
410
191
291
387
166
235

485
248
422
489
234
360
469
223
347
446
199
292

527
255
403
506
232
349

537
277
489
514
251
413
443
187
273
776
374
700
732
361
608
673
311
507
627
274
415

530
236
368
890
432
814
846
424
725
788
373
627
745
339
539

1003
489
927
961
487
841
903
435
746
862
404
663

1017
498
866
980
469
787

1399
745
1294
1264
662
1074
1247
511
752

Notes: Spring-return, quarter-turn actuators use pressure and springs(s) to produce torque.
Start: (starting) That torque output position at which a spring-return actuator produces its greatest torque output during a spring stroke. The starting
torque output listed in Bettis spring-return torque output charts is that torque output position, where the spring is fully compressed, and capable of
transferring its maximum force.
Minimum: (min.) That torque output, at an intermediate position, at which an actuator produces its lowest torque output. The minimum torque
outputs listed on the Bettis spring torque output charts are the lowest value of torque output produced at any position, during either stroke (pressure or
spring).
End: (ending) That torque output position, at which an actuator has reached the limit of the spring stroke. The spring ending torque output values listed
on Bettis spring-return torque output charts is the torque output value where the spring is fully extended and is transferring its lowest force value.

Dimensions CBA-Series (Pneumatic) Imperial


Double-Acting Actuators
CBAXXX

Actuator
Model
CBA315
CBA420
CBA520
CBA525
CBA725

Actuator
Model
CBA315

A
14.16
16.43
16.46
19.22
19.44

B
7.38
8.57
8.63
9.88
10.24

C
3.25
4.25
5.38
5.38
7.50

D
1.09
1.38
1.38
1.69
1.69

E
1.88
2.13
2.07
2.56
2.53

F
3.46
4.37
4.37
5.00
5.00

G
0.94
1.10
1.10
1.25
1.25

H
.94
1.10
1.10
1.25
1.25

.313-18 UNC

1.125

2.91

5.81

.75

2.22

5.18

.375-16 UNC

1.500

3.35

6.69

.75

2.81

6.25

.375-16 UNC

1.500

3.35

6.69

.75

2.81

6.25

.500-13 UNC

1.750

4.38

8.75

1.12

3.50

7.58

.500-13 UNC

1.750

4.38

8.75

1.12

3.50

7.58

CBA420
CBA520
CBA525
CBA725

Note: Not Certified dimensional drawings. Such drawings available on


request. Contact factory with correct model designation and
serial number.
All dimensions are expressed in inches.

10

J/K
1/4 NPT
3/8 NPT
3/8 NPT
3/8 NPT
3/8 NPT

W
.614
.620
.864
.870
.864
.870
1.115
1.121
1.115
1.121

L
.313-18 UNC
.375-16 UNC
.375-16 UNC
.500-13 UNC
.500-13 UNC

M
.38
.50
.50
.50
.50

N
2.250
3.000
3.000
3.500
3.500

AA
0.873
0.875
1.123
1.125
1.121
1.125
1.498
1.500
1.498
1.500

1.03

3.75

1.09

1.03

4.63

1.38

1.03

4.63

1.38

1.50

5.75

1.69

1.50

5.75

1.69

Dimensions CBA-Series (Pneumatic) metric


Double-Acting Actuators
CBAXXX

Actuator
Model
CBA315
CBA420
CBA520
CBA525
CBA725

Actuator
Model
CBA315

A
359.8
417.3
418.1
488.1
492.7

B
187.5
217.6
219.2
250.9
260.1

C
82.6
108.0
136.7
136.7
190.5

D
27.8
34.9
34.9
42.9
42.9

E
47.8
54.1
53.5
65.0
64.2

F
87.8
111.0
111.0
127.0
127.0

G
23.8
27.9
27.9
31.8
31.8

H
23.9
27.9
27.9
28.4
28.4

.313-18 UNC

28.6

73.8

147.6

19.1

56.4

131.5

.375-16 UNC

38.1

85.1

169.9

19.1

71.3

158.9

.375-16 UNC

38.1

85.1

169.9

19.1

71.3

158.9

.500-13 UNC

44.5

111.1

222.3

28.4

88.9

192.6

.500-13 UNC

44.5

111.1

222.3

28.4

88.9

192.6

CBA420
CBA520
CBA525
CBA725

J/K
1/4 NPT
3/8 NPT
3/8 NPT
3/8 NPT
3/8 NPT

W
15.6
15.73
22.09
21.09
22.09
21.09
28.33
24.47
28.32
28.48

L
.313-18 UNC
.375-16 UNC
.375-16 UNC
.500-13 UNC
.500-13 UNC

M
9.7
12.7
12.7
12.7
12.7

26.2

95.3

27.8

26.2

117.5

35.1

26.2

117.5

35.1

38.1

146.1

42.9

38.1

146.1

42.9

N
57.2
76.2
76.2
88.9
88.9

AA
22.15
22.25
28.5
28.6
28.5
28.6
38.02
38.12
38.02
38.12

Note: Not Certified dimensional drawings. Such drawings available


on request. Contact factory with correct model designation
and serial number.
All dimensions are expressed in millimeters.

11

Dimensions CBA-Series (Pneumatic) Imperial


Spring Return Actuators
CBA XXX-SRX

Actuator
Model
CBA315-SRX
CBA415-SRX
CBA420-SRX
CBA520-SRX
CBA525-SRX
CBA725-SRX
Actuator
Model

A
20.13
20.20
24.54
24.88
28.21
28.09

B
13.66
13.71
17.07
17.44
18.01
18.37

C
3.25
4.25
4.25
5.38
5.38
7.50

D
1.09
1.09
1.38
1.38
1.69
1.69

F
3.46
3.46
4.37
4.37
5.00
5.00

G
0.94
0.94
1.10
1.10
1.25
1.25

H
.94
.94
1.10
1.10
1.25
1.25

J/K
1/4 NPT
1/4 NPT
3/8 NPT
3/8 NPT
3/8 NPT
3/8 NPT

L
.313-18 UNC
.313-18 UNC
.375-16 UNC
.375-16 UNC
.500-13 UNC
.500-13 UNC

AA

CBA315-SRX

.38

2.250

1.125

2.91

5.81

.75

2.22

5.18

3.75

1.09

.38

2.250

1.125

2.91

5.81

.75

2.22

5.18

1.03

3.75

1.09

CBA420-SRX

.50

3.000

1.500

3.35

6.69

.75

2.81

6.25

1.03

4.63

1.38

CBA520-SRX

.50

3.000

1.500

3.35

6.69

.75

2.81

6.25

1.03

4.63

1.38

CBA525-SRX

.50

3.500

1.750

3.50

8.75

1.12

3.50

7.58

1.50

5.75

1.69

CBA725-SRX

.50

3.500

1.750

3.50

8.75

1.12

3.50

7.58

.614
.620
.614
.620
.864
.870
.864
.870
1.115
1.121
1.115
1.121

1.03

CBA415-SRX

.31318 UNC
.313
-18 UNC
.375
-16 UNC
.375
-16 UNC
.500
-13 UNC
.500
-13 UNC

1.50

5.75

1.69

0.873
0.875
0.871
0.875
1.123
1.125
1.121
1.125
1.498
1.500
1.498
1.500

Note: Not Certified dimensional drawings. Such drawings available on


request. Contact factory with correct model designation and
serial number.
All dimensions are expressed in inches.

12

E
1.88
1.88
2.13
2.07
2.56
2.53

Dimensions CBA-Series (Pneumatic) metric


Spring Return Actuators
CBA XXX-SRX

Actuator
Model
CBA315-SRX
CBA415-SRX
CBA420-SRX
CBA520-SRX
CBA525-SRX
CBA725-SRX
Actuator
Model

A
511.2
513.3
623.3
631.9
716.6
713.6

B
347.0
348.2
433.5
442.9
457.4
466.7

C
82.6
108.0
108.0
136.7
136.7
190.5

D
27.8
27.8
34.9
34.9
42.9
42.9

E
47.8
47.8
54.1
52.2
65.0
64.2

F
87.8
87.8
111.0
111.0
127.0
127.0

G
23.8
23.9
27.9
27.9
31.8
31.8

H
23.9
23.9
27.9
27.9
28.4
28.4

J/K
1/4 NPT
1/4 NPT
3/8 NPT
3/8 NPT
3/8 NPT
3/8 NPT

L
.313-18 ULC
.313-18 ULC
.375-16 UNC
.375-16 UNC
.500-13 UNC
.500-13 UNC

AA

CBA315-SRX

9.7

57.2

28.6

73.8

147.6

19.1

56.4

131.5

95.3

27.8

9.7

57.2

28.6

73.8

147.6

19.1

56.4

131.5

26.2

95.3

27.8

CBA420-SRX

12.7

76.2

38.1

85.1

169.9

19.1

71.3

158.9

26.2

117.5

35.1

CBA520-SRX

12.7

76.2

38.1

85.1

169.9

19.1

71.3

158.9

26.2

117.5

35.1

CBA525-SRX

12.7

88.9

44.5

111.1

222.3

28.4

88.9

192.6

38.1

146.1

42.9

CBA725-SRX

12.7

88.9

44.5

111.1

222.3

28.4

88.9

192.6

15.6
15.73
15.59
15.75
22.09
21.09
22.09
21.09
28.33
24.47
28.32
28.48

26.2

CBA415-SRX

.31318 UNC
.313
-18 UNC
.375
-16 UNC
.375
-16 UNC
.500
-13 UNC
.500
-13 UNC

38.1

146.1

42.9

22.15
22.25
22.12
22.22
28.5
28.6
28.5
28.6
38.02
38.12
38.02
38.12

Note: Not Certified dimensional drawings. Such drawings available


on request. Contact factory with correct model designation
and serial number.
All dimensions are expressed in millimeters.

13

Dimensions CBA-Series (Pneumatic) in/mm

M3HW Override

Double-Acting Actuators
CBA XXX-M3HW

Actuator
Model
CBA315-M3HW
CBA420-M3HW
CBA520-M3HW
CBA525-M3HW
CBA725-M3HW

in
mm
in
mm
in
mm
in
mm
in
mm

25.23
640.8
30.58
776.8
30.58
776.8
36.52
927.5
36.65
930.8

13.01
365.0
15.82
401.8
15.85
402.5
18.92
480.5
19.08
484.6

3.25
82.6
4.25
108.0
5.25
133.4
5.25
133.4
7.50
190.5

6.00
152.4
8.00
203.2
8.00
203.2
10.00
254.0
10.00
254.0

1/4 NPT

1/4 NPT

3/8 NPT

3/8 NPT

3/8 NPT

3/8 NPT

3/8 NPT

3/8 NPT

3/8 NPT

3/8 NPT

1.88
47.6
2.13
54.0
2.09
53.2
2.56
65.0
2.53
64.2

24.21
614.9
29.12
739.6
29.06
738.0
34.17
867.9
34.17
867.9

14.37
365.0
17.37
441.1
17.37
441.1
20.31
515.8
20.31
515.8

Spring Return Actuators


CBA XXX-SRX-M3

Note: Not Certified dimensional drawings. Such drawings available on


request. Contact factory with correct model designation and
serial number.
All dimensions are expressed in inches.
Actuator
Model
CBA315-SR-M3HW
CBA415-SR-M3HW
CBA420-SR-M3HW
CBA520-SR-M3HW
CBA525-SR-M3HW
CBA725-SR-M3HW

14

in
mm
in
mm
in
mm
in
mm
in
mm
in
mm

26.66
677.1
26.74
679.1
32.13
816.2
32.16
816.8
36.93
937.9
36.98
939.2

14.43
366.5
14.51
368.6
17.37
441.3
17.43
442.7
19.33
491.0
19.41
493.1

3.25
82.6
4.25
108.0
4.25
108.0
5.38
136.7
5.38
136.7
7.50
190.5

6.00
152.4
6.00
152.4
8.00
203.2
8.00
203.2
10.00
254.0
10.00
254.0

1/4 NPT

9.84
249.9
9.84
249.9
11.69
297.0
11.69
297.0
13.86
351.9
13.86
352.1

1.88
47.6
1.88
47.6
2.13
54.0
2.09
53.2
2.56
65.0
2.53
64.2

3.47
88.2
3.47
88.2
4.38
111.1
4.38
111.1
5.00
127.0
5.00
127.0

1/4 NPT
3/8 NPT
3/8 NPT
3/8 NPT
3/8 NPT

K
3.47
88.2
4.38
111.1
4.38
111.1
5.00
127.0
5.00
127.0

Options

SIL-PAC
The unique SIL-PAC solution provides a complete hardware and
Bettis-supplied documentation package, embracing IEC, ISA and
OSHA standards, for use in a SIL application. The CBA-Series actuators have
a Failure Modes and Effects Diagnostics Analysis (FMEDA) report
performed by Exida.com for SIL suitability. They can be combined with
other components such as solenoid valves, switches and regulators. When
Fishers TV-certified FIELDVUE DVC controller is added, SIL-PAC is capable
of partial stroke testing PLUS providing continuous monitoring of supply
pressure, valve position and pressure values to the actuator to verify its
proper working condition. The SIL-PAC package can then be mounted
on the appropriate quarter-turn valve as a final control solution suitable for
SIL1, 2 or 3 applications.

Bettis Automated Packages


Bettis offers complete packages as a solution for final valve control.
Bettis has the capability to combine the CBA actuator, necessary
controls and selected valve into a single system perfect
for large international projects.
With this capability, Bettis can integrate its products with the complete offering of control options, including world-class
PlantWeb digital plant architecture and the entire range of
Emerson automation solutions.

BettiSystemsTM
Bettis has pre-engineered and documented a series of commonly required
control systems. These approved systems utilize standard components,
reduce lead times, and simplify purchasing, installation and start-up. Please
consult the factory for additional information.

M3/M3HW
This blowout-proof Jackscrew manual override is a mechanical advantage
device threaded through a special adapter or the end cap of the CBA-Series
cylinder to exert linear thrust on the actuators piston rod. The Jackscrew
override is available for all CBA models, with (HW) or without handwheel.
It provides fully-rated torque output if air supply is lost.

BettiStopTM Partial Stroke Test Device


This external-mount device is sandwiched between the CBA-Series actuator
and the valve. It is ideal for periodic testing of Emergency Shutdown valves
(ESD) while remaining in service and is used for other safety process flow
applications. It is particularly useful where compliance with ANSI/ISA S84.01,
OSHA CFR 1910.119 and IEC 61508/61511 are applicable.
The BettiStop can test a valve automation package by mechanically limiting
valve stem rotation, clockwise or counter-clockwise, to 20 degrees as standard
or 15 degrees optionally. When disengaged, the BettiStop does not interfere
with the actuated valve. Consult factory for additional information.

15

ORDERING / MODEL DESIGNATION

OPTIONAL FEATURES

Spring-Return Example

Double-Acting Example

CBA 4 20 SR80-M3-CW

CBA 3 15

Fail-Safe Operation

Nominal Cylinder Size (3.0 In.)

Jackscrew Override
Spring-Return (80 PSIG nominal)

Each Bettis CBA actuator is capable of

Nominal Moment Arm (e.g. 1.5 In.) fail-safe operation using either stored

Fail CW or CCW

Center Bar

compressed gas (air) or a mechanical


spring.

Trims
Trim options for CBA-Series actuators
include seals for high and low temperature
applications and no copper or yellow
metals. The N-Series actuator is
designed to resist affects of environmental
conditions and seismic loading design
criteria imposed by the Nuclear Power
Industry. Consult Bettis for more information on these and other specific trims.

Nominal Moment Arm (e.g. 2.0 In.)


Nominal Cylinder Size (4.0 In.)
Center Bar

Contact Us: Emerson Process Management, Valve Automation facilities at your nearest location:
North & South America

Europe

Middle East & Africa

18703 GH Circle
PO Box 508
Waller, Texas 77484
USA
T +1 281 727 5300
F +1 281 727 5353

Asveldweg 11
7556 BT Hengelo(O)
The Netherlands
T +31 74 256 1010
F +31 74 291 0938

2 Monteer Road, Isando


Kempton Park, 1600
South Africa
T +27 11 974 3336
F +27 11 974 7005

Siemensring 112
D-47877 Willich
Germany
T +49 2154 499 660
F +49 2154 499 6613

PO Box 17033
Jebel Ali Free Zone
Dubai,
United Arab Emirates
T +971 4883 5235
F +971 4883 5312

2500 Park Avenue West


Mansfield, Ohio 44906
USA
T +1 419 529 4311
F +1 419 529 3688
9009 King Palm Drive
Tampa , Florida 33619
USA
T +1 813 630 2255
F +1 813 630 9449

30/36 Allee du Plateau


93250 Villemomble
France
T +331 48 122610
F +331 48 122619

Asia Pacific

4112-91A Street
Edmonton, Alberta T6E5V2
Canada
T +1 780 450 3600
F +1 780 450 1400

6 Bracken Hill
South West Industrial Estate
Peterlee, Co Durham
SR82LS, United Kingdom
T +44 191 518 0020
F +44 191 518 0032

Av. Hollingsworth,325
Iporanga
Sorocaba, SP 18087-105
Brazil
T +55 15 3238 3788
F +55 15 3228 3300

3 Furze Court
114 Wickham Road
Fareham, Hampshire
PO167SH ,United Kingdom
T +44 132 984 8900
F +44 132 984 8901

19, Kian Teck Crescent,


Singapore 628885
T +65 6262 4515
F +65 6268 0028
9/F Gateway Building
No.10 Ya Bao Road
Chaoyang District
Beijing, P.R. China
T +86 10 5821 1188
F +86 10 5821 1100

No 15 Xing Wang Road


Wuqing Development Area
Tianjin 301700
P.R. China
T +86 22 8212 3300
F +86 22 8212 3308
Lot 13111, Mukim Labu,
Kawasan Perindustrian Nilai
71807 Nilai, Negeri Sembilan
Malaysia
T +60 6 799 2323
F +60 6 799 9942
471 Mountain Highway
Bayswater, Victoria 3153
Australia
T +61 3 9721 0200
F +61 3 9720 0588
301, Solitaire Corporate Park
151, M.V. Road, Andheri(E)
Mumbai-400093,
Maharashtra, India
T +91 22 6694 2711
F +91 22 2825 3394
NOF Shinagawa Konan Building
1-2-5, Higashi-shinagawa
Shinagawa-Ku, Tokyo
140-0002 Japan
T +81 3 5769 6873
F +81 3 5769 6902

2008 Emerson Process Management. All rights reserved.


The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand mark listing are marks of one of the Emerson Process Management family of companies.
All other marks are property of their respective owners.
The contents of this publication are presented for information purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed
as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and
conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.
The color orange, U.S. Reg. No. 2,739,393, is a registered trademark of the Bettis Corporation.

www.Bettis.com

Bettis Brochure # 20.00-6 REV: 6-08 5M/6-08