Cerberus PRO

Fire control panel


FS720 series, IP6

A6V10203220_h_en_-2015-10-23

Compact, pre-assembled, microprocessor-controlled standalone fire control


panel with integrated operating unit for up to 126 addresses
Detection and automatic reading in (auto-configuration) of all C-NET devices,
ready for operation immediately
Processes signals from Cerberus PRO FD720 detector series
Integrated degraded mode function
Fast Ethernet interface for remote control service
Can be extended by adding key switches
Slot for one RS232 or RS485 serial interface
Emergency power supply for emergency operating time of up to 72 hours
Floor repeater displays, floor repeater operating units, and alarm devices on
detector line (C-NET)
Flexible configuration of complex applications and controls
Configuration data can be uploaded/downloaded via remote access
Firmware for all processor-controlled control panel components can be
updated

Building Technologies
Control Products and Systems

System overview
Remote access
Engineering Tool,
Operating Tool

FC721

Fire control panel

FDM233-Ex
Explosionhazard area
OOH740-A9-Ex

Detection line collective Siemens,


SynovaTM SynoLINE300 or
SynoLINE600

RT- Alarm
RT-Fault

24VDC ext.
FDS221/
FDS229

Fire controls

FDCI222

FDCL221-Ex

FDCIO223

2 in-/outputs
optionally

FT2010/FT2011
Floor repeater terminal/
Floor repeater
display

4 inputs
DBS721 / DBS729

C-NET

HI720

OH720

1 loop
max. 126 addresses

DBS720
HI722
24VDC ext.
possible

stub line

FDCL221

Conventional horn line


via FCI2009-A1

OP720 OP720

FDA221/
FDA241

1 output
FDCIO221

OH720

FDCW241
4 outputs

FDCI221

1 input

FDCI723
FDM22x
Mimic display
FT2001-A1

FDM221
FDCIO222
4 inputs

1 input

FDOOT271
FDM273
Radio detectors

Function features

The FC721 is a compact standalone fire control panel with integrated operating
unit for processing signals from FD720 devices.
The control panel is custom-configured using the Cerberus-Engineering-Tool
software.
All the detector lines are monitored for ground faults.
Customer texts can be adapted directly on the operating unit of the control
panel or with the Cerberus-Engineering-Tool software.
Up to 2000 events can be retrieved from the event memory based on various
criteria.
Automatic summer/winter time changeover

2
Building Technologies
Fire Safety

A6V10203220_h_en_-2015-10-23

Function elements

Operating unit
The following elements are available on the operating unit:
CPU module and electronics
Ethernet connection
Slot for RS232 or RS485 module
Space for 'Kaba' or 'Nordic' key switch
Periphery board
Connection terminals for the following elements are available on the periphery board:
C-NET lines
Remote transmission (alarm, fault)
Horn output
Configurable control inputs and outputs
Monitored alarm and fault output
Power supply
Power supply unit 70 W, emergency power supply
The power supply feeds the hardware and charges the batteries.
In the event of a power cut, the batteries provide emergency current.
Configuration
The FXS7212 Cerberus-Engineering-Tool allows the system to be customized.
Application ranges

The FC721 is ideal for smaller applications, e.g., for use in workshops or hotels.

3
Building Technologies
Fire Safety

A6V10203220_h_en_-2015-10-23

Indication and operating elements


Each FC721 has an integrated operating unit.
1
FC7 21-ZZ

2
1
ALARM

9
User 2
User 3

User 1

Silence buzzer

3
7

User 4

More Alarms

FAULT

Remote alarm
Active
Fault / Off

ISOLATION

Acknowledge
Reset

Alarm delay Off


Premises manned

Alarm device
DETECTOR TEST

Active
Fault / Off

System

Control function

On
Fault

Active
Fault / Off

User 5
User 6

13

3
FC7 21-YZ

2
1

ALARM

9
User 2
User 3

User 1

Silence buzzer

3
7

User 4

More Alarms

FAULT

Remote alarm
Active
Fault / Off

ISOLATION

4
5
6

Acknowledge
Reset

Alarm delay Off


Premises manned

Alarm device
DETECTOR TEST

Active
Fault / Off

System

Control function

On
Fault

Active
Fault / Off

13

User 5

7
8
9

User 6

10
11
12
13
14

8-line display with 40 characters per line with


detailed text information about all events that
occur:
Event type, event location, action texts,
operating states
Instructions displayed directly in alarm
situations to tell you what to do
Convenient operation via soft keys and
navigation button
Alarm indicator, lights up red when an alarm
event occurs
Four configurable LEDs and associated
inscription fields
Soft keys for direct operation depending on state
Two buttons with LEDs, individually configurable
Buttons for 'Buzzer off', 'Acknowledge' message,
and 'Reset' message
Button for scrolling through alarm messages
Navigation and menu buttons
Keypad for entering numeric and alphanumeric
texts, e.g., password or customer text
Alarm organization buttons
Button and LEDs with inscription fields for
alarming equipment
Optional key switch for operating access (Kaba
or Nordic)
Insertable inscription strips
24 indicator groups with one red/green and one
yellow LED each

4
Building Technologies
Fire Safety

A6V10203220_h_en_-2015-10-23

Overview of fire control panels FC721


Housing (Eco)
FC721-ZZ

FC721-YZ
Featuring 24 indicator groups
with one red/green + one yellow LED each

1 loop

1 loop

with power supply (70 W)

with power supply (70 W)

Max. battery capacity 7 Ah

Max. battery capacity 7 Ah

Empty housing for free use


FH7201-Z3

FH7202-Z3

Housing (Eco)

Housing (Standard)

430 x 398 x 103 mm

430 x 398 x 183 mm

E.g., for extra batteries,


Operating add-ons or

E.g., for extra batteries

Event printer

Power supply
Space for batteries
2x FA2003-A1 (7 Ah) or
2x FA2004-A1 (12 Ah)

Internal printer
FTO2001-A1

External printer
DL3750+

Event printer

Matrix printer (external)


RS232 interface

For installation in empty housing


RS232 module must
be ordered separately
RS232 module must
be ordered separately

5
Building Technologies
Fire Safety

A6V10203220_h_en_-2015-10-23

Layout of FC721

11

7 1

12
5

6
10

Basic equipment
1
Housing (Eco)
2
Periphery board (1-loop)
3
Power supply (70 W)

Designation
FH7201-A1
FCI2010-A1
FP2015-A1

Notes
Items 1-5: Basic equipment for each FC721 (Eco)

4
Mains terminals on TS35 DIN rail
5
Operating unit
6
Space for batteries
Extensions
7
Relay module
Key switch (Kaba)
8
Key switch (nordic)
RS485 module (isolated) or
9
RS232 module (isolated)
10 Battery (12 V, 7 Ah, VDS)
11 19" mounting kit
12 Cable kit (communication)

FCM72xx-xx

Space for two relay modules


Operating unit with CPU
2x 12 V/7 Ah

Z3B171
FTO2005-C1
FTO2006-B1
FCA2002-A1
FCA2001-A1
FA2003-A1
FHA2016-A1
FCA2014-A1

Relay for fire controls


For operating access authorization
For peripheral devices with RS485 interface
For devices with an RS232 interface
For the emergency power supply
For installation in 19" third-party housing
For flexible cable joints running to the modules on the operating unit

6
Building Technologies
Fire Safety

A6V10203220_h_en_-2015-10-23

Technical data
Mains voltage
Power supply
Operating voltage
Operating current
Battery capacity
Battery monitoring
Network monitoring
Connectable detector series
Number of lines
Loop or
Stub
Number of addresses
Integrated inputs/outputs
Relay output
RT alarm
RT fault
Monitored outputs
Alarm
Fault
Horn
Freely programmable inputs/outputs
Operating unit
Slot for serial interface
RS232 or RS485
Mounting space for cable kit (communication)

AC 97127 V/AC 196253 V


70 W
DC 20.528.6 V
Max. 2.5 A
2x 12 V, 7 Ah
Yes
Yes
Cerberus PRO FD720 (C-NET)

Ethernet connection RJ45


Operating temperature
Storage temperature

1
-8+42 C
-20+60 C
95 % rel.

Air humidity (no moisture condensation permitted)


Dimensions (W x H x D)
Without cover cap
With cover cap
Color
Housing
Cover cap
Protection category (IEC 60529)
Approvals
LPCB
FM

1 loop with 126 C-NET devices


2 stubs with 32 C-NET devices
Max. 126

1
1
1
1
1
4
Integrated
1
1

430 x 398 x 80 mm
430 x 398 x 103 mm

~RAL 7035, light gray


~RAL 000 50 00
IP30
126bn/05

3051081

7
Building Technologies
Fire Safety

A6V10203220_h_en_-2015-10-23

Details for ordering


Control panels
Extensions

Auxiliary power supply

Batteries

External printer
Spare part

Type

Art. no.

Designation

FC721-ZZ
FC721-YZ
Z3B171
FTO2001-A1

FTO2005-C1
FTO2006-B1
FCA2002-A1
FCA2001-A1
FCA2014-A1
FH7201-Z3
FH7202-Z3
FHA2016-A1
FP2015-A1
FP2004-A1

S54400-C32-A2
S54400-C32-A3
BPZ:4843830001
A5Q00010126
A5Q00017619
A5Q00010113
A5Q00010129
A5Q00009923
A5Q00005327
A5Q00023027
S54400-B72-A101
S54400-B70-A101
A5Q00020179
S54400-B121-A1
A5Q00020825

FA2003-A1
FA2004-A1
FA2006-A1
DL3750+

A5Q00019353
A5Q00019354
A5Q00019356
A5Q00023962
A5Q00023963

Fire control panel (1L)


Fire control panel (1L, 1LED)
Relay module AC 250 V / 10 A (1 relay)
Event printer
Spare printer reels (10 reels)
Key switch (Kaba)
Key switch (nordic)
RS485 module (isolated)
RS232 module (isolated)
Cable kit (communication)
Housing (Eco)
Housing (Standard)
19" mounting kit
Power supply (70 W)
Power supply kit (150 W, A) for installation
into empty housing
Battery (12 V, 7 Ah, VDS)
Battery (12 V, 12 Ah, VDS)
Battery (12 V, 26 Ah, VDS)
Matrix printer (external)
Color ribbon for matrix printer DL3750+

Siemens Switzerland Ltd


Building Technologies Division
International Headquarters
Gubelstrasse 22
CH-6301 Zug
Tel. +41 41 724 24 24
www.siemens.com/buildingtechnologies
Document ID

A6V10203220_h_en_--

Edition

2015-10-23

Weight
8.900 kg
9.000 kg
0.042 kg
0.250 kg
0.090 kg
0.013 kg
0.050 kg
0.067 kg
0.068 kg
0.224 kg
5.700 kg
7.500 kg
3.000 kg
1.300 kg
1.366 kg
2.450 kg
3.930 kg
7.572 kg
7.300 kg
0.078 kg

Siemens Switzerland Ltd, 2008


Technical specifications and availability subject to change without notice.
FS720 manual

You might also like