Cylindrical fuse links gG class for use as general protection against overloads and short circuits, intended as protection of
cables, power lines and equipment. Made of ceramic tube with high withstand to internal pressure and thermal shock, that
allow a high breaking capacity in a reduced physical space. The melting elements are specially designed in order to avoid aging
and thus maintain unalterable the electrical characteristics. Contact caps are made of silver plated copper. Versions available
with fusing indicator or with striker for use in fuse holders with microswitch.
www.df-sa.es/cylindrical/fuses/gG/
In
8x32
10x38
BREAKING CAPACITY
REFERENCE
BREAKING CAPACITY
PACKING
(A)
WITHOUT
INDICATOR
REFERENCE
WITH
INDICATOR
(V)
(kA)
WITH
STRIKER
(V)
(kA)
Uni./BOX
0,5
1
2
4
6
8
10
12
16
20
420500
420501
420502
420504
420506
420508
420510
420512
420516
420720
420602
420604
420606
420608
420610
420612
420616
420820
400
400
400
400
400
400
400
400
400
400
20
20
20
20
20
20
20
20
20
20
10/100
10/100
10/100
10/100
10/100
10/100
10/100
10/100
10/100
10/100
0,5
1
2
4
6
8
10
12
16
20
25
32*
420000
420001
420002
420004
420006
420008
420010
420012
420016
420020
420025
420032
420102
420104
420106
420108
420110
420112
420116
420120
420125
420132
500
500
500
500
500
500
500
500
500
500
500
400
120
120
120
120
120
120
120
120
120
120
120
120
10/100
10/100
10/100
10/100
10/100
10/100
10/100
10/100
10/100
10/100
10/100
10/100
1
2
4
6
8
10
12
16
20
25
32
40
50
421001
421002
421004
421006
421008
421010
421012
421016
421020
421025
421032
421040
421050
421102
421104
421106
421108
421110
421112
421116
421120
421125
421132
421140
421150
690
690
690
690
690
690
690
690
690
690
500
500
400
80
80
80
80
80
80
80
80
80
80
120
120
120
421202
421204
421206
421208
421210
421212
421216
421220
421225
421232
421240
421250
500
500
500
500
500
500
500
500
500
500
500
400
120
120
120
120
120
120
120
120
120
120
120
120
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
STANDARDS
APPROVALS
420500
420025
* Overrating fuses
14x51
IEC 60269-1
IEC 60269-2
EN 60269-1
EN 60269-2
|4
TECHNICAL
t-I AND CUT-OFF
CHARACTERISTICS
D I R E C T I V E
2002/95/EC
12
PAGE
TECHNICAL
I2t CHARACTERISTICS
AND POWER
DISSIPATION
13
PAGE
TECHNICAL
DC APPLICATIONS FOR
CYLINDRICAL FUSES
24
PAGE
COMPATIBLE
PMF MODULAR
FUSE HOLDERS
06
PAGE
COMPATIBLE
PMX MODULAR
FUSE HOLDERS
07
PAGE
COMPATIBLE
PMC & PMCC
FUSE HOLDERS
09
PAGE
COMPATIBLE
SC SCREW FIXING &
BAC OPEN FUSE
HOLDERS
10
PAGE
CYLINDRICAL
FUSES
gG CYLINDRICAL FUSES
In
22x58
BREAKING CAPACITY
REFERENCE
BREAKING CAPACITY
PACKING
(A)
WITHOUT
INDICATOR
REFERENCE
WITH
INDICATOR
(V)
(kA)
WITH
STRIKER
(V)
(kA)
Uni./BOX
2
4
6
8
10
12
16
20
25
32
40
50
63
80
100
125*
422002
422004
422006
422008
422010
422012
422016
422020
422025
422032
422040
422050
422063
422080
422000
422015
422102
422104
422106
422108
422110
422112
422116
422120
422125
422132
422140
422150
422163
422180
422100
422115
690
690
690
690
690
690
690
690
690
690
690
690
690
500
500
400
80
80
80
80
80
80
80
80
80
80
80
80
80
120
120
120
422204
422206
422208
422210
422212
422216
422220
422225
422232
422240
422250
422263
422280
422200
422215
690
690
690
690
690
690
690
690
690
690
690
690
500
500
400
80
80
80
80
80
80
80
80
80
80
80
80
120
120
120
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
10/50
* Overrating fuses
gG NEUTRAL LINKS
aM
8x32
10x38
14x51
22x58
SIZE
REFERENCE
PACKING
Uni./BOX
8x31
10x38
14x51
22x58
430000
431000
432000
433000
10/100
10/100
10/50
10/50
431000
TECHNICAL
FUSES
gG CYLINDRICAL
DIMENSIONS
SIZE
8,5x31,5
8,5
31,5
6,3
10,3x38
14,3x51
22,2x58
10,3
14,3
22,2
38
51
58
8,5
11,5
15,5
8
8
4
4
COMPATIBLE
PMP PANEL MOUNTING
& PMB SOCKET FUSE
HOLDERS
11
PAGE
5|
CYLINDRICAL
FUSES
TECHNICAL
FUSES
gG CYLINDRICAL
t-I CHARACTERISTICS
TECHNICAL
FUSES
gG CYLINDRICAL
CUT-OFF CHARACTERISTICS
|8
CYLINDRICAL
FUSES
TECHNICAL
FUSES
gG CYLINDRICAL
I2t CHARACTERISTICS
TECHNICAL
FUSES
gG CYLINDRICAL
POWER DISSIPATION
In
SIZE
8,5x32
10x38
14x51
22x58
(A)
(VW)
(VW)
(VW)
(VW)
0,5
1
2
4
6
8
10
12
16
20
25
32
40
50
63
80
100
125
1,2
2,0
0,5
0,8
1,1
1,3
1,0
1,2
1,5
2,0
1,43
2,77
0,60
0,70
0,85
0,75
1,00
1,30
1,60
2,00
2,60
2,90
3,90
0,90
1,00
1,15
1,00
1,30
1,70
2,00
2,50
3,30
3,50
4,75
4,80
1,00
1,10
1,30
1,10
1,50
1,80
2,10
2,70
3,30
3,50
4,00
5,50
6,90
7,80
9,00
11,4
9|
CYLINDRICAL
FUSES
TECHNICAL
FUSES
gG CYLINDRICAL
DC APLICATIONS
Fuses are generally suitable for both AC and DC applications. The DC performance of fuse-links is different and AC ratings cannot be
used for DC applications. There is no simple rule that safely converts an AC voltage rating of a fuse-link to DC voltage rating. For this
reason it is necessary to take into account a lot of aspects in order to determine the DC applications.
In the DF ELECTRIC gG cylindrical fuses it is necessary to take into account the following considerations:
The power dissipations are the same in AC (RMS value) and the DC values.
The time current characteristics are the same for DC applications under steady-state conditions.
The DC rated voltage and maximum breaking capacity are lower than the AC values (see the table).
SIZE
RATED CURRENT
MAX. DC VOLTAGE
DC BREAKING CAPACITY
8,5x31,5
0,5A...10A
12A...20A
0,5A...16A
20A...32A
1A...25A
32A & 40A
50A
2A...63A
80A & 100A
125A
150V DC
60V DC
250V DC
80V DC
440V DC
80V DC
48V DC
440V DC
80V DC
48V DC
5 kA
10x38
14x51
22x58
NOTES
These values are referred to a time constant L/R = 15 ms.
For higher values of time constant, the maximum utilization voltage must be reduced.
For circuits with very inductive behaviour, we recommend to connect two fuses in series.
|12
15 kA
15 kA
15 kA