You are on page 1of 1

1

6
CLIENT

10

11

12

KING FAISAL
SPECIALIST HOSPITAL
AND
RESEARCH CENTRE

13

100800

8400

8400

8400

8400

8400

8400

8400

8400

CONSULTANT:

400

400

400

400

400

SUB CONSULTANT:
250 300

6400

300

CORE No. 01
& STAIR No. 02

300
400

400

8400

400

400

400

NOTES:
400

150 150

C1
400

C1
400

C1
400

400

C1
400

C1
400

C1

300

1350

3000

4250

1650

300

8400

2200

90000

300

400

2450

Saudi Diyar Consultants

6950

400

3.

ALL DIMENSIONS ARE IN MILLIMETERS.

4.

IN CASE OF ANY DISCREPANCY BETWEEN STRUCTURAL


DRAWINGS & SITE CONDITIONS, REFER TO THE
CONSULTING ENGINEER.

5.

ALL PIPE SLEEVES & OTHER BUILDER'S WORK


REQUIREMENTS FOR ELECTRO-MECHANICAL WORKS,
SHALL BE COORDINATED WITH THE APPROVED
ELECTRO-MECHANICAL SHOP DRAWINGS BEFORE
CONCRETING.

6.

FOR COLUMNS, FOOTING DETAILS & SCHEDULES


REFER TO DRAWING NO. 1257B03-S701.

7.

ALL PERIMETER COLUMNS SHALL CONTINUE UP TO


PARAPET LEVEL, UNLESS OTHERWISE INDICATED.

400

400

8.

FOR SIZES & LOCATIONS OF SLAB OPENINGS,


TRENCHES & PITS REFER TO ELECTRO-MECH.
DRAWINGS.

9.

SOIL BEARING CAPACITY BELOW FOUNDATION SHALL


NOT BE LESS THAN 2.50 Kg/sqcm . CONTRACTOR SHALL
VERIFY THIS ASSUMPTION BEFORE STARTING
CONSTRUCTION . IN CASE OF ANY DISCREPANCY
BETWEEN THE DESIGN SOIL BEARING CAPACITY & SOIL
CONDITION REFER TO CONSULTING ENGINEER.

400

C1

400

C1

400

C1

400

400

400

C1

400

400

400

10. PLAIN CONCRETE USED IN BLINDING SHALL HAVE


MINIMUM 28 DAYS CYLINDER STRENGTH OF 200
KG/SQ.CM.

400

400

C1

C1

400

400

C1

400

400

11. REINFORCING STEEL BARS SHALL BE DEFORMED HIGH


GRADE STEEL OF YIELD STRENGTH 4200 KG/SQ.CM.
(MIN.)
12. UNLESS OTHERWISE SPECIFIED. REINFORCED
CONCRETE SHALL HAVE A MIN. 28 DAYS CYLINDER .
STRENGTH OF 400 KG/SQ.CM.

400

8400

400

C1

400

C1

400

C1

400

C1

400

400

400

400

C1

C1

400

C1

400

8400

400

ALL DIMENSIONS & LEVELS ARE TO BE COORDINATED


WITH ARCHITECTURAL & CIVIL DRAWINGS.

1257B03-S101c

C1
400

MATCH LINE SEE DWG NO. 1257B03-S101b

400

2.
400

1257B03-S101c

C1

FOR GENERAL NOTES, SEE DWG. NO. 1257B01-S001...

C1

300

400

1.

400

400

400

400

400

C1

400

C1

400

C1

400

400

REV.NO.

DESCRIPTION

DATE

KEY PLAN

400

400

C1
400

C1
400

C1
400

400

C1
400

C1

1
250 1175 250

A
1225 250

250 935 300

7800

PROJECT MANAGER
2900

1875

CORE No. 06
& STAIR No. 05

300

250

AM

YS

400

C1
2150

FA

MECHANICAL
MA

ICT
ZM

CIVIL/LS

DRAWN BY

CHECKED BY

AE/HF

HM

AR

PROJECT TITLE:

400
400

STRUCTURAL

C1

400

400

400

C1

400

C1

400

SL

ELECTRICAL

50

250

ARCHITECT

400

2800

1500

250

2570

2550

MATCH LINE SEE DWG NO. 1257B03-S101b

250
250

C1

100 300

1250 100

250 425
400

300

300

400

1830

C1
250

250

400

C1

6000

L1

250

2275

50

1875

400

2275

300

3450

400

2080

250

1350
CORE No. 08
& STAIR No. 04

400

400

C1

300

400

250
2275

1000 250

7800

2950

300

1650

1830

300

250

2900

1495

600 250

250

250

1830

2275

8400

250

12

250

KING FAISAL
SPECIALIST HOSPITAL
AND
RESEARCH CENTRE

400

Jeddah - Saudi Arabia

B03 KITCHEN & LAUNDRY


DRAWING TITLE:

PARTIAL
COLUMNS & AXES LAYOUT
PART d
COLUMNS & AXES LAYOUT - PART d
1d PARTIAL
SCALE
1:100 M.
0

SCALE 1:100

IC
T
A

10
METERS

EM

SC

SCALE

DATE

CAD FILE

1:100

JUNE 2014

1257B03-S101

DRAWING NUMBER

1257B03-S101d

REVISION

0
Saudi Diyar Consultants