Test report No. 161 22335/1.0.0 e Date of report Customer Order Specimen Contents Inst fr Fenstertechnik eV. Ute Prot Dipl Ing ove! Schid ‘Teodor Set F8 Fenster Tiren Fassaden Werkstoffe Zubehor ROSENHEIM 15 december 1999 SCHUCO International KG. Karolinenstrae 1-15 D-33609 Bielefeld Determination of the airborne sound insulation of a facade ‘element with fixed glazing according to the German standard DIN 52210 and DIN EN ISO 717-1 (Aptitude testing I for DIN 4109) Facade element with fixed glazing of the product designation ,FW 60" 1 Definition of task 2 Test specimen 3 Test procedure 4 Test results 5. Information for use of i,f.t test reports Measurement sheet (1 page) ‘Annex (1 page) Telefon (08031) 261.0 Sparkasso Rosonin: “obfar (0 89 31) 251-290, lo, 38 22 (2 71 50000) eral noe osonom de Pocischockamt Wunchen Intpuwweadosennawn se 00, 2848 26.801 (BLE 700100 80) Page 2ota 3° Test report 161 22335/1.0.0e of 15 december 1999 Company _SCHUCO International KG, -39609 Biolefeld ROSENHEIM 1 Definition of task The i.f. Rosenheim was charged by SCHUCO International KG, D-33609 Bielefeld, to determine the airborne sound insulation according to DIN 52210 and DIN EN ISO 717-1 of a facade element with fixed glazing of the product designation ,FW 60" This test serves for the evidence of aptitude for the requirements stated in DIN 4109 (aptitude test 1) 2 Test specimen Specimen Facade element System name FW 60° Frame material Aluminium profile with thermal break, untreated surface Frame Exterior dimensions 1230 mm x 1480 mm Mullion cross-section 156,5mm x 60mm Transom cross-section 132,5mmx 60mm Glazing Insulating glass unit Designation / Type Phonstop 42/54 cast resin Visible pane dimensions 1110 mm x 1360 mm. Pane construction 13 cast resin/20/Scast resin (mm) Total thickness: 42 mm Filing in pane space 58% Argon, 11% SF, (according to if. analysis) Glass sealing exterior and interior with sealing profiles Vapour pressure balance __by profiles in mullions The facade element with fixed glazing can be seen in cross-section in the measurement sheet and in the annex. ‘Specimen collection Production of the specimens by the customer regarding the necessary dimensions. Delivery of specimen 29 november 1999 Date of test 29 november 1999 3 Test procedure The test specimen was mounted into the test opening of the partition wall of the window test rig P-F according to DIN 52210-02:1984 using a mounting frame which was weighted with lead. It was butt-jointed as prescribed for installation type 2, it was wedged and secured and was opened and closed several times. The connecting joints were completely stuffed with plastic foam and sealed on both sides with plastic sealant of type Perennator 2001 S grey. Page 3of4 2 Test report 161 22335/1.0.0e of 15 december 1999 Company _ SCHUCO International KG, D-33609 Bielefeld TO ROSENHEIM For measuring the airborne sound insulation a test noise was generated using a dodecahedron loudspeaker in the source room. With a two-channel measurement system for building acoustics the sound level difference between the sound level L, in the source room and the sound level L, in the receiving room was measured at least at two positions of the loudspeakers according to DIN 52210-1:1984-08. The microphones automatically moved through the room on a circular path ‘Two measurements of the reverberation were carried out in the receiving room using two positions of loudspeaker and microphone each. The reverberation times T were achieved by taking the arithmetic average. The equivalent area of absorption A is calculated using the volume V of the receiving room as follows: A= 0,163. m T From the measurement values and the test area S of the test specimen the sound reduction index R is calculated following the function: R=L,-L, +10 os dB The measurement was carried out using the following equipment Apparatus Type Producer Integrating measurement device Type Nortronic 840 Norsonic-Tippkemper Microphone-preamplifier Type 1201 Norsonic-Tippkemper Microphone Type 1220 Norsonic-Tippkemper Pistonphone Type 4220 Briel & Kjaer Loudspeaker dodecahedron Type 229, 95 Ohm Norsonic-Tippkemper Amplifier Type 235, 100 W Norsonic-Tippkemper Rotating microphone Type 231-N-360 Norsonic-Tippkemper In three year intervals the if. attends to comparing measurements at the Physikalisch- Technische Bundesanstalt (Federal institution for physical-technical affairs) at Braun- schweig. The sound level meter of the acoustic measurement system is regularly calibrated at the Eichamt (Office of weights and measures) at Dortmund. The complete measuring arrangement is calibrated at the beginning of a sound level measurement. The if. Rosenheim is included as no. “BAY 18” into the “list of bodies for testing, surveillance and certification according to the land's building directive” issued by the DIBt. 4 Test results 4.1 Tested and calculated values The values of the measured airborne sound reduction index of the tested facade element with fixed glazing are drawn-up in the diagram of the annexed data sheet as a function of the frequency and are given in the following table: Page 40f4 @ Test report 161 22335/1.0.0e of 15 december 1999 Company _ SCHUCO Intemational KG, 0-33609 Bielefeld ROSENHEIM finHz | 50 63 80 | 100 125 160 | 200 250 315 | 400 _500_630 RindB | 376 31,8 338| 303 39,0 324| 355 393 42,9 | 45,0 47.0 484 finHz | 800 1000 1250 | 1600 2000 2500 | 3150 4000 5000 Rind’ | 49.2 490 476[ 459 506 546 | 578 586 584 From that the weighted sound reduction index Ry, according to DIN EN ISO 717-1: 1997-01 can be calculated for the frequency range from 100 Hz to 3150 and the spectrum adaption terms C and C,; Ry (CiCy) = 48 (-45-5) dB According to DIN EN ISO 717-1:1997-01 further spectrum adaptation terms result from that Cosi = -1 dB Croo.so00 = 0 dB Ceoso0 = 0 dB Cysoso = -8 dB Cr. ro08000 -5 dB Cysos00 = -5 dB For the evidence of aptitude according to DIN 4109 is valid: Tested value Ryp=48d8 and calculated value Ryp= 46 dB ‘The characteristic values Ryp and Ry as well as the required margin between laboratory measurements and in-situ measurements (2 dB) correspond to DIN 4109 : 1989-11. of test results The values given in this test report are only valid for the specimen described in item 2. General conclusions for the construction and other functional details may not be drawn from this test report. 5 Information for use of i.f.t. test reports Regulations for the use of test reports are given in the enclosed information sheet Conditions and information for use of i.ft. test reports for publication and commercial purposes". i.ft. Rosenheim }ept. Sound insulation Pr6f. Josef Schmid Dr. Rolf Schumacher Sound insulation index acc. to DIN 52210 - 3 Aptitude testing I Customer: SCHUCO International KG, D-33609 Bielefeld for DIN 4109 Specimen Facade element with fixed glazing Frame material Aluminium profile for facades Window system FW60* Dimensions 1230 mm x 1480 mm Glazing Insulating glass unit Phonstop 42/54 cast resin Pane construction 13 cast resin/20/9cast resin (mm) Filling in space 58% Argon, 11% SF. (according to if.t. analysis) curve of reference measurement curve Test ace. to DIN 6210-03-61. P-F.2 Dale oftest_ 29 november 1999 Area of test 4,25 m x 1,50 m= 1,88 m2 2 60 Laboratory —_Tworleaf concrete wall, 5 partion wall DIN 6210-2: 1984 c Test noise Pink noise § Volumes of Vg = 108,9m3 = 50 testroome — Ve= 401.3 m3 fe Max. possible Ry,mac= 62 dB 3 sound reduction (Felted to test area) 2 Mounting Window builtin buttjointed totest- 5 40 conditions opening and secured with wedges. Connecting joints completely stutfed with plastic foam and sealed with plastic sealants on both sides. 30 Rp from diagram Rif) Rug = Rup 2dB 20 Weighted sound reduction indices R,, Tested value Ryp = 48 dB Calculated value Rye = 46 4B 40 125° 250 © 500.» 1000-2000 Frequency f in Hz lead of testing laboratory Dr. Rolf Schumacher ‘Test report No.: 161 22335/1.0.0 € Wo —— 9 \ | er. if.t. Rosenheim, 15 december 1999 ROSENHEIM Annex Page 1 of 1 o Test report 161 22335/1.0.0e of 15 december 1999 Company _ SCHUCO International KG, D-33609 Bielefeld ROSENHEIM Note This annex was composed using documents ofthe customer. There was no complete examination for technical corectness. ‘xanurivopRovexrenera2sa6e75100¢ 000

You might also like