You are on page 1of 16

Warning

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

PCSME0561

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorized parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
For any inquiries, contact your local distributor.

AIR CONDITIONING SYSTEM


C OOLING ONLY [ 50 Hz ]
For high outdoor temperature use

Cautions on product corrotion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an
outdoor unit with anti-corrosion treatment.

The air conditioners manufactured


by Daikin Industries have
received ISO 9001 certification for
quality assurance.
Certificate Number. JMI-0107

JQA-0495
JQA-1452

Dealer

All Daikin Industries locations


and subsidiaries in Japan have
received environmental
management system standard
ISO 14001 certification.
Daikin Industries, Ltd.
Domestic Group

Certificate Number. EC99J2044

About ISO 14001


ISO 14001 is the standard defined by the
International Organization for Standardization (ISO)
relating to environmental management systems.
Our group has been acknowledged by an
internationally accredited compliance organisation
as having an appropriate programme of
environmental protection procedures and activities
to meet the requirements of ISO 14001.

Head Office:
Umeda Center Bldg., 4-12, Nakazaki-Nishi
2-chome, Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
Shinjuku Sumitomo Bldg., 6-1, Nishi-Shinjuku
2-chome, Shinjuku-ku, Tokyo, 163-0235 Japan

http://www.daikin.com/global/
c All rights reserved

Printed in Japan 11/05/003 SW HP SS

The specifications, designs, and information in this brochure are subject to change without notice.

Cooling only
Capacity *1

HP

2.5

10

15

20

Ton

1.5

1.8

2.2

3.0

3.6

4.0

4.8

6.8

8.3

13.6

16.6

Btu/h

18,100

21,800

26,300

35,800

43,700

48,500

57,300

81,900

99,600

163,400

199,300

kcal/h

4,560

5,500

6,600

9,000

11,000

12,200

14,400

20,600

25,100

41,200

50,200

5.3

6.4

7.7

10.5

12.8

14.2

16.8

24.0

29.2

47.9

58.4

FHC50KVE

FHC60KVE

FHC100KVE

FHC125KVE

FH50BVE

FH60BVE

FH100BVE

FH125BVE

FHK45FV1

FHK60FV1

FHB45FV1

FHB60FV1

FD08KY1

FD10KY1

RU10KUY1
RU10KY1

RU08KUY1 2
RU08KY1 2

RU10KUY1 2
RU10KY1 2

RU08K(U)Y1

RU10K(U)Y1

RU08K(U)Y1 2

RU10K(U)Y1 2

kW

CEILING MOUNTED
CASSETTE TYPE

Page 4 6

Indoor unit

Specifications Page 16

Outdoor unit

R50GV1K

R60GV1K

FHC71KVE

R71FUV1 / Y1

R100FUV1 / Y1

R125FUY1

CEILING SUSPENDED TYPE


Page 7
Specifications Page 16

Indoor unit
Outdoor unit

R50GV1K

R60GV1K

FH71BVE

R71FUV1 / Y1

R100FUV1 / Y1

R125FUY1

CEILING MOUNTED
CASSETTE CORNER TYPE

Page 8

Indoor unit

Specifications Page 17

Outdoor unit

R50GV1K

R60GV1K

CEILING MOUNTED
BUILT-IN TYPE

Page 8

Indoor unit

Specifications Page 17

Outdoor unit

R50GV1K

R60GV1K

WALL MOUNTED TYPE


Page 9
Specifications Page 18

FA71FVEK

Indoor unit

R71FUV1 / Y1

Outdoor unit

FA100FVEK

R100FUV1 / Y1

FLOOR STANDING TYPE


Page 9
Specifications Page 18

FV71LAVE

Indoor unit

R71FUV1 / Y1

Outdoor unit

PACKAGED AIR CONDITIONERS

FV100LAVE

R100FUV1 / Y1

FV125LAVE
R125FUY1

LOW STATIC
PRESSURE TYPE

Specifications Page 20

Indoor unit

Outdoor unit

FDBG50AVE
R50GV1K

FDBG60AVE
R60GV1K

FDBG71AVE
R71FUV1 / Y1

MIDDLE STATIC
PRESSURE TYPE

(FDMG)

(FDMG)

DUCT
CONNECTION
Page 10 11

Specifications Page 19

(FDM)

Indoor unit

Outdoor unit

HIGH STATIC
PRESSURE TYPE

Specifications Page 20,21

Indoor unit

Outdoor unit
Outdoor unit

FDMG71AV1

FDMG100AV1

FDMG125AV1

FDM03FAV1
R71FUV1 / Y1

FDM04FAV1

R100FUV1 / Y1

FDM05FAV1

FD03KY1

FD04KY1

FD05KY1

FD06KY1

R71FUV1 RG71AV1
R71FUY1 RG71AY1

R100FUV1
R100FUY1

R125FUY1

RG140AY1 RU06KY1

RG71AV1 / Y1

Outdoor unit
Indoor unit

(Type without factory charged refrigerant)

(FDM)

(FDMG)

R71FUY1

R100FUV1 / Y1

R100FUY1

R125FUY1

FDMG140AV1
RG140AY1

(FDMG)

FDMG180AV1
RG180AY1

R125FUY1

R125FUY1

RU06KY1

RU08KUY1
RU08KY1

FD15KY1

FD20KY1

OUTDOOR UNIT
Page 12
R50GV1K

Notes)

R60GV1K

of FD series are gross capacities which do not include a deduction for evaporator fan motor heat.
*Capacities
*Capacities except FD series are net, including a deduction for cooling for indoor fan motor heat.
*1. The values given for 2HP5HP Ton, Btu/h, kcal/h, kW on the right are for the FHYC type. The values given for 6HP7HP Ton, Btu/h, kcal/h, kW on the right are for the FDMG type.
The values given for 8HP20HP Ton, Btu/h, kcal/h, kW on the right are for the FD type.

Specifications for Ton, Btu/h, kcal/h, kW are based on the following conditions: Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB
1

Equivalent ref. piping:5 m(Horizontal)

RG180AY1

Cooling only
Simultaneous operation system TWIN MULTI OPERATION

Capacity *1

Page 13 14

Page 13 14
Specifications
Page 22 24

Specifications
Page 22 24

TRIPLE MULTI OPERATION

HP

10

Ton

6.3

7.6

6.3

Btu/h

75,700

90,800

75,700

kcal/h

19,100

22,900

19,100

22.2

26.6

22.2

FHYC100KVE 2
R200KUY1

FHYC125KVE 2
R250KUY1

FHYC71KVE 3
R200KUY1

kW

CEILING
MOUNTED CASSETTE
CEILING-MOUNTED
CASSETTE TYPE
TYPE

FHC50125K / FHYC50125K

FHYC50125KVE for twin / triple / double twin multi connection


Sound level

3 5 /3 0 dB
[High]

[Low]

Accessory required for indoor unit (option)


Wired LCD remote controller

Wireless LCD remote controller

FHC71K

A signal rec eiver must be


added to the indoor unit.

CEILING MOUNTED
CASSETTE TYPE
Indoor unit
Outdoor unit

BRC1C61
Note: R emote c ontroller c able not
inc luded. C ables must be
proc ured loc ally.

CEILING SUSPENDED
TYPE
Indoor unit
Outdoor unit

Outdoor unit

FHY100BVE 2
R200KUY1

FHY125BVE 2
R250KUY1

FHY71BVE 3
R200KUY1

Freedom of selection of installation location


FDYM04FAV1 2
R200KUY1

FDYM05FAV1 2
R250KUY1

FDYM03FAV1 3
R200KUY1

OUTDOOR UNIT

Since a multi-flow system is used, 4-way, 3way or 2-way air flow can easily be
selected, permitting installation in
locations corresponding to interior

Can also be installed in high ceilings.

Max. 4.2 m(FHYC100K125K)

Note : For 3-way or 2-way air flow installation,


the sealing member (option) for air
discharge outlet must be used to
close off the unused outlet(s).

Page 12
R200KUY1

R250KUY1

R200KUY1

*1. The values given for Ton, Btu/h, kcal/h, kW on the right are for the FHYC type.

Criteria for ceiling height and number of air flow outlets

Specifications for Ton, Btu/h, kcal/h, kW are based on the following conditions:

Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB Equivalent ref. piping:5 m(Horizontal)

Simultaneous operation system DOUBLE TWIN MULTI OPERATION

Capacity *1

Page 13 14

Specifications
Page 22 24

HP

10

Ton

6.3

7.6

Btu/h

75,700

90,800

kcal/h

19,100

22,900

22.2

26.6

FHYC50KVE 4
R200KUY1

FHYC60KVE 4
R250KUY1

kW

Simultaneously
running 2 to 4 units
distributes comfort
across wide rooms.

Number of air flow outlets used

Ceiling
height
Simultaneous control with
2 units in spacious room

Outdoor unit

CEILING SUSPENDED
TYPE
Indoor unit
Outdoor unit

High ceiling

50K71K
3-way
air flow

2.7 m
3.0 m
3.5 m

3.0 m
3.3 m
3.5 m

2-way
air flow

4-way
air flow

3.5 m
3.8 m

3.2 m
3.6 m
4.2 m

100K125K
3-way
2-way
air flow
air flow

3.6 m
4.0 m
4.2 m

4.2 m
4.2 m

There are 3 patterns in auto swing operation


Pattern
Simultaneous control with
3 units for irregularly shaped room

FHY50BVE 4
R200KUY1

Standard
High ceiling

4-way
air flow

Note: Set to standard 4-way air flow when shipped.


High ceiling types
and
will be set for
remote control operation.

CEILING MOUNTED
CASSETTE TYPE
Indoor unit

Signal receiver unit


(Installed type)

Wireles s remote c ontroller and s ignal


rec eiver unit are s old as a s et.

DUCT CONNECTION
MIDDLE STATIC PRESSURE
TYPE
Indoor unit

BRC7C613W

Standard setting

Pattern

Swings within the range of 10 to 65.

Draft prevention setting

Pattern

Swing angle is set from 10 to 40 so


people are not subjected to strong winds
(Recommended where there are seats near
the air conditioner).

FHY60BVE 4
R250KUY1

Setting to prevent soiling of ceiling

Swing angle is within a range of 30 to 65


to prevent blowing against the ceiling.
(This recommended for those who are
particular about cleanliness of the ceiling).

OUTDOOR UNIT
Page 12

Simultaneous air conditioning by


distributing 4 units in a large room

R200KUY1

R250KUY1

*1. The values given for Ton, Btu/h, kcal/h, kW on the right are for the FHYC type.

10

10

65

Specifications for Ton, Btu/h, kcal/h, kW are based on the following conditions:

Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB Equivalent ref. piping:5 m(Horizontal)

65

10

10
40

40

Has been set to standard setting at time of shipment. This can be changed using the remote control.
3

30

30
65

65

Super cassette type is more compact, lighter and


easier to install than the conventional types.
Maintainability also greatly improved.

Maintenance is simple
Soiling of ceiling reduced 3040% (compared to conventional models).
Conventional system

Non-dew flap

Stepping motor
Newly set angle

Uniform panel size for all models.

Newly set angle

Presently set angle

The conventional 100 125 models' rectangular panel types have all been
converted to the same compact square type as the 50 71models. This
permits smooth interior harmony of ceilings with the lighting fixtures.
Installation of multiple air conditioners of different capacities will also be

Presently set angle

The ceiling tends to become soiled by


dust in the air temporarily blowing out
horizontally when resetting the flap angle.

950 mm

Thanks to the stepping motor,the flap can


be set to the new setting directly
preventing soiling due to the air flow not
hitting the ceiling.

A high efficiency mildew-proof long-life filter is provided as


standard parts. Maintenance not required for about one year
(2, 500 hrs).

Quiet design

100~125

950 mm

Although flocking is presently used on flaps to prevent dewing, the


new flaps are "Non-dew Flaps" that do not soil easily and are easy to

New system

Horizontal
discharge

Compact and aesthetic square panel type

Uses the newly developed "Diffuser Turbo Fan" with application


of aircraft technology.

50~71

Quiet operation is realized by a unified structure of 3-dimensional


blades and air diffuser for arranging the flow of air in the air
conditioner.

1340 mm
(Conventional FHC125F)
(

Cleaning is simple because of the "Non-dew Flap" with no flocking.

Diffuser

FHC125F)

Maintenance cost reduced since cleaning of the heat exchanger


is only necessary once every 3 years.
Maintenance cost is reduced by using a high-efficiency long-life filter
since maintenance is required only once every 3 years as compared
to once every 2 years as was previously the case.

Once

Once
2years

Two Select thermo-sensors


Thermo-sensors on both indoor unit and wired remote controller (option). Temperature detection can be set closer to
the living area to further improve comfort level.

(Conventional model)

3-Dimensional blade

Indoor unit

* Indoor unit's thermo-sensor must be used when the air conditioner is controlled
from another room. (Wireless remote controller does not have a thermo-sensor.)

FHC71K
FHC125K

3years

High

Low

35 dB
42 dB

30 dB
36 dB

(New model)

Top class of the industry

Note: Operating sound may increase more than that when used with 3-way air flow
or 2-way air flow, or when used together with a optional kit.

Using the optional accessories produces an even higher level of comfort


Fresh air intake kit (Option)

Main unit is lighter and more compact to


further simplify installation

Allows intake of fresh air from the outdoors. When neither heating
nor cooling is required, fresh air can be circulated by only using the
fan. This is especially useful in buildings in which ventilation fans

5 kg lighte r tha n c onve ntiona l


mod e ls.

Adjustment pockets in the four corners of


the panel make height adjustment of the
main unit much easier.

28 kg

840 m m

840

mm

123

0 mm

In addition to discharging air from the outlet on the decoration panel,


a duct can be connected to the air conditioner itself for an additional
discharge outlet. The additional discharge outlet is useful for areas
which tend to be crowded or near doors or windows where the
temperature is affected by the outside temperature.

Simplifies height adjustment of the main


unit.

FH(Y)C100K 125K

33 kg

Branch duct chamber (Option)

Fresh air intake kit

Intake duct

Air filter

(Outdoor)
Hood

Branch duct chamber

The FH(Y)C50K 71K are thin


models (230 mm) which can
be installed in narrow false
ceiling space.

Discharge duct

Note : Intake duct, hood, air filter, insect screen, fireproof damper, etc. must be procured at a local outlet if needed.

Wid th is a pproxima te ly 2/3 of


the c onve ntiona l mod e l's wid th.

Provided with high lift drain


water lift-up mechanism
(Increased lift of drain pipe up
to 750 mm from the ceiling).

Min. 245 mm

Discharge panel

Three types of kits are available for


specific installation conditions.
For the details, see page.25.

Notes :

Use only one branch duct chamber per air conditioner.


Close the decoration panel's outlet on the chamber installation side with the sealer
for the air discharge outlet.

750 mm

( ) 50

(Option)

Because of the light weight, suspension is possible without an


upper lift.

Note :
Discharge duct, discharge panel, etc.
must be procured at a local outlet if
needed.

CEILING MOUNTED CASSETTE CORNER TYPE

CEILING SUSPENDED TYPE

FHK4560F

FH50125B / FHY50125B

FHY50125BVE for twin / triple / double twin multi connection

Accessory required for indoor unit (option)

Sound level

Accessory required for indoor unit (option)


Wired LCD remote controller

4 1 /3 6 dB

Wireless LCD remote controller

[High]

A signal rec eiver must be


added to the indoor unit.

Sound level

Upgrade to an even
more quiet and
compact system.

3 9 /3 5 dB
[High]

Signal receiver unit


(Installed type)

BRC1C61
Note: R emote c ontroller c able not
inc luded. C ables must be
proc ured loc ally.

[Low]

FHY71B

BRC7EA66

Wired LCD remote controller

[Low]

BRC1C61

FHK60F

Note: R emote c ontroller c able not


inc luded. C ables must be
proc ured loc ally.

Uni-directional discharge outlet is perfect for corner


installation. A thin, 21.5 cm main body enables
installation even in a small ceiling overhead space.

Wireles s remote c ontroller and s ignal


rec eiver unit are s old as a s et.

Free downward or forward air flow


corresponding to installation location.
Downward air flow

Distributes comforting air flow throughout the room

Downward blow + forward air flow

Forward air flow

Auto-swing for comfort in all directions.

(Note) For forward discharge installation, remove


the duct seal-off plate on the front face of main
body and install the discharge grille and the flexible
duct with shutter. The auto swing function cannot
be used during forward discharge operation.

Wide air discharge openings produce a spreading 100 air flow.

CEILING MOUNTED BUILT-IN TYPE

New model

FHB4560F

100

Maintenance is simple
Installable on ceilings
3. 5 m high.

Accessory required for indoor unit (option)

Sound level

Long-life Filter lasts about 1 year *


Maintenance not required.
* For dust concentration of 0.15 mg/m3

Two time settings (2500 hrs and 1250 hrs) are available to match the installation
environment. Maintenance time warning is displayed on the remote controller
(filter sign).

Two Select thermo-sensors


Thermo-sensors on both indoor unit and wired remote controller (option). Temperature detection can be set closer to
the living area to further improve comfort level.

Bristle-free Flap minimizes


contamination and makes
cleaning simpler.

Drain-up kit (option) can be


easily incorporated.

4 1 /3 5 dB
[High]

[Low]

BRC1C61

FHB60F

With the use of simple ducts, discharge outlets can be


located in a multitude of ways. Top priority given to interior
decor, built-in type units realize ideal air current distribution.

New Non-dew Flap with no implanted bristles.

* Indoor unit's thermo-sensor must be used when the air conditioner is controlled
from another room. (Wireless remote controller does not have a thermo-sensor.)

Wired LCD remote controller

Non-dew Flap

By separating the air outlet from the main unit and blowing air, various
conditions will be cleared such as in modified stores, state of sunshine
and gathering of people to realize comfortable air conditioning.

600 mm
Drain-up kit (built inside main unit)

Note: R emote c ontroller c able not


inc luded. C ables must be
proc ured loc ally.

WALL MOUNTED TYPE

FA71/100F

Accessory required for indoor unit (option)


Wired LCD remote controller

Wireless LCD remote controller

Sound level

FDYM0305FAV1 for twin / triple multi connection


Sound level

A signal rec eiver must be


added to the indoor unit.

4 1 /3 7 dB
[High]

DUCT CONNECTION MIDDLE STATIC


FDMG71180A
PRESSURE TYPE
FDM0305FA
4 2 /3 8 dB

[Low]

[High]

FA71F

Accessory required for indoor unit (option)

[Low]

For FD(Y)M

FDMG71A

Signal receiver unit


(Installed type)

BRC1C61
Note: R emote c ontroller c able not
inc luded. C ables must be
proc ured loc ally.

Wall mounted type units feature the lowest


sound levels in the industry and greatly upgraded
comfort, thanks to the high fan speed mode.

Wired LCD remote controller

(FDMG)

Wireless LCD remote controller


A signal rec eiver must be
added to the indoor unit.

BRC7C69W
Wireles s remote c ontroller and s ignal
rec eiver unit are s old as a s et.

(FDM)

These duct type air conditioners can be installed in


the ceiling space for an attractive interior finish.
Daikin's middle static pressure duct type air
conditioners are compact and quiet, well-suited for
use in a wide variety of duct type air conditioning
systems for homes, stores, and offices.

"High fan speed mode" for further comfort.


If an indoor "High fan speed mode" type unit is installed in a long,
narrow store or in the corner of a room,there is approximately a 10%
increase in air volume. A comfortable air stream will reach distant areas.

BRC1C61
Note: R emote c ontroller c able not
inc luded. C ables must be
proc ured loc ally.

BRC4C62

Wireles s remote c ontroller and s ignal


rec eiver unit are s old as a s et.

For FDMG

Digital remote controller

Superior freedom of layout


duct system allows the most efficient location of discharge outlets
The
in accordance with the room layout.
standard-equipment rear intake chamber simplifies the duct
The
connecting work.
305 mm height design makes installation possible where the
Compact,
ceiling space is limited.

FLOOR STANDING TYPE

Signal receiver unit


(Separate type)

Remote controller

KRC47-2 / KRC47-4

KRC47-1

(FDMG)

FV71125LA

Sound level

Floor standing type units are easy to install


and maintain; their slimness is suitable for
installation in high-ceiling stores and offices.

4 1 /3 5 dB
[High]

[Low]

FV71LA

Ordinary duct
(procured locally)
Liquid crystal control panel
(Standard equipment)

Air conditioner
295 mm *1

305 mm *2 or more
Air intake

Air blow

The panel can also be removed and used for remote


control such as controlling air conditioning from a
different room or from near the cashier.

Ordinary duct
(procured locally)

FD(Y)M0305FA only

*1 305mm thic k with FDMG


*2 315 mm thic k with FDMG

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
These units are number one in the world in quietness and lightness.
The use of a high-efficiency, Long-life Filter reduces maintenance time and cost.

Maintenance cycle
Parts

Previous model

Filter

Once

Heat exchanger

Once

2 weeks
2 year

When air conditioning two rooms simultaneously, the air


discharged into each room must be circulated back to the air
conditioner. To ensure this, a ventilation duct should be
installed for each room or one of the indicated ventilation
grilles should be installed on the partitioning wall or under the
door between the rooms.

Door-installed
ventilation grille

New model
Once
Once

1 year
3 year

Partitioning wall

Ventilates air through the


partitioning wall. (see right)

Ventilation grille

Ventilation grille

Under-door cutout

Note : The under-door cutout method should be used only


when there is a small volume of air flow.

The heat exchanger has been subjected to antibacterial treatment and mildew proofing.

Wall-installed
ventilation grille Under-door cutout

10

DUCT CONNECTION LOW STATIC


FDBG2571A
PRESSURE TYPE
Accessory required for indoor unit (option)

Sound level

Digital remote controller

4 1 /3 8 dB

Remote controller
R71FU
RG71A

[Low]

R60G

R50G

FDBG50A

By placing the main unit into the false ceiling, the


room's design and finish remain beautiful and
undisturbed. Together with minimal operating
sound,the units are perfect for rooms where
atmosphere is important.

KRC47-2 / KRC47-4

KRC47-1

R100 /125FU

RU06K
RG140/180A

RU08K/08KU
R200KU

RU10K/10KU
R250KU

Reduces installation space.


( Applies to R71125FU)

Equipped with "high static pressure" fan.


Long hypotenuse blades
(Optimal camber)

Long hypotenuse blades with a gentle camber make the pressure rise on the
surface of the blades smooth and uniform, while suppressing break away of the
flow. As a result, it prevents rise in draft resistance produced due to lack of
open space behind the unit, and prevents air power from dropping.

50

50

[High]

Outdoor Unit

"Air Flow Adjustment Guide" (standard equipment).

Cross-section of "Air Flow Adjustment Guide".

( Applies to R71125FU)

Outdoor units include as standard equipment the "Air Flow Adjustment Guide"
which lets you set as desired the air flow in any one of four directions in
accordance with your layout. Cushions effect of air flow striking against
obstructions in front of the unit (walls,etc.) and prevents "short circuits" from being
formed.

Suction Chamber
(standard equipment)
Air Filter (Field supply)

fig.1.0.

DUCT CONNECTION HIGH STATIC


FD0320K
PRESSURE TYPE

As show in the diagram, the air flow adjustment guide is factory set so that exhaust air flow
is inclined 30 degrees. The guide can be set to direct the air flow to the left, right or down
as well as upward, so you can adjust the direction according to the place of installation.

Accessory required for indoor unit (option)

Sound level

Digital remote controller

Remote controller

4 6 dB
[Low]

FD05KY1

FD15KY1

30

Anti-Corrosion treatment of heat exchange fins.

Magnification of corrosion resistance


Against salt corrosion

( Applies to all outdoor units )

The special acrylic precoated fin (PE fin) for anti-corrosion treatment on the
outdoor unit heat exchanger ensures greater resistance against salt damage
and atmospheric pollution than ever.

FD03K

Corrosion
resistance grade

Against acid corrosion

Non-treated fin

PE fin

Non-treated fin

PE fin

5 6

5 6

Construction.

KRC47-5

High static pressure that allows long duct and


long refrigerant piping enables flexible
installation. Recommended for spacious and
large-volume areas like large stores or factories.

Hydrophilic film
Aluminium
C orrosion resistanc e ac rylic resin

Aluminium

KRC47-3

RU08/10K models are available in two types


depending on installation conditions
RU08/10KU models are factory shipped with refrigerant charged for 5
meters of piping. RU08/10K models are factory shipped with no
refrigerant charged.

Main functions for extra comfort.

*Please look for available functions for the model you select.

Auto-swing

Program "Dry"

Fan operation
mode

Self diagnosis
function

OPTIONAL
FUNCTIONS

Auto-restart

Timer selector

Long-life filter

Two select
thermo-sensors

Fresh air intake

Mold resistant
treatment for filter

Filter sign

Ceiling soiling
prevention

High ceiling
application

High fan
speed mode

Twin / triple /
double twin multi
application
(See page 13~16)

11

12

Anti-corrosion treatment of
outdoor heat
exchanger fins

Simultaneous operation system

Indoor units include the ceiling mounted cassette type & ceiling suspended type
& duct connection middle static pressure type.

Multi Series

Twin, Triple, and Double Twin Multi Application Operation

Simultaneously operates 2 to 4
indoor units with a single
outdoor unit.

Double Twin multi Operation

Four indoor units can be run simultaneously with a single outdoor unit.

In large rooms where air-conditioning can be uneven with a


single indoor unit, you can spread comfortable air-condition to
every inch by installing 2 to 4 indoor units according to how
crowded the lighting conditions are.

Branch piping kit


Branch piping kit
Branch piping kit

Four indoor units distribute comfortable air flow through out the room.
Simultaneous operation of four indoor units can be controlled from
a single remote controller.
Requires a single refrigerant piping system.

In a one-floor restaurant, for example, positioning


4 units at strategic locations realizes comfortable
air flow that reaches every inch of the room.
Note: This system is not capable of individually operating or controlling
indoor units. It is not suitable for large rooms with partitioned areas.

Triple Multi Operation

Installing multiple units


is economical and
ensures comfort.
Costs less to install than individual pair
type.

Branch piping kit

Enables you to save space for outdoor


units.
Installing indoor units in several locations
eliminates uneven air-conditioning and

Multi Series Product Line-up


Simultaneous Operation System

Twin Multi Operation


Twin Multi

Triple Multi

DoubleTwin Multi

CEILING MOUNTED
CASSETTE TYPE

FHYC100KVE
x2

FHYC125KVE
x2

FHYC71KVE
x3

FHYC50KVE
x4

FHYC60KVE
x4

CEILING SUSPENDED
TYPE

FHY100BVE
x2

FHY125BVE
x2

FHY71BVE
x3

FHY50BVE
x4

FHY60BVE
x4

FDYM04FAV1
x2

FDYM05FAV1
x2

FDYM03FAV1
x3

R200KUY1

R250KUY1

R200KUY1

DUCT CONNECTION
MIDDLE STATIC
PRESSURE TYPE

OUTDOOR UNIT

13

R200KUY1

Branch piping kit

R250KUY1

14

Multi Series

Simultaneous operation system

Twin, Triple, and Double Twin Multi Application Operation

Wired LCD remote controller

Wireless LCD remote controller

Option

CEILING MOUNTED CASSETTE TYPE

CEILING SUSPENDED TYPE

Option

DUCT CONNECTION MIDDLE STATIC PRESSURE


TYPE

BRC7EA66

Option

Option

BRC1C61

BRC4C64

Connect the wired remote controller to turn an indoor unit


into the master unit.

Wired remote controller has a thermo-sensor. Depending on


the installation conditions, select and set the thermo-sensor
of a selected indoor unit or the thermo-sensor of the remote
controller.

Because the wireless remote controller does not have a thermosensor, select the thermo-sensor of an indoor unit.

Triple Multi Operation

L1

L2

Main pipe
L

Outdoor unit

Maximum piping length


Maximum branch piping length
Maximum branch pipe length difference

Sub
unit

Sub
unit

Main
unit

L3

L3

Distributed
piping kit

Remote
controller

Simultaneous operation system

Operation range
Colour
Outdoor
Compressor type
unit
Motor output
Refrigerant charge (R22)
Sound level
*2
Dimensions (HX WX D)
Machine weight
Operation range
Liquid (Flare)
Piping
connections Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

Double Twin Multi Operation

Sub
unit

Main
unit

L2

Main pipe
L

Sub
unit

L4

L5

L1
Remote
controller

Distributed
piping kit

Sub
unit

L2

Max (L1, L2)

* Max (L1, L2)


Max (L1, L2)

20 m

*2 Min (L1, L2)

Max (L1, L2, L3)


Max (L1, L2 , L3)

10 m

Max (L1, L2, L3)

50 m
20 m

Min (L1, L2, L3)

10 m

Double Twin Multi Operation


L

Max (L1, L2)

Max ( L1, L2 )
(L2 L6)

Max (L3, L4, L5, L6)


Max ( L3, L4, L5, L6 )

(L1 L3) 10 m
L2 L1 10 m
L4 L3 10 m
L6 L5 10 m
L2,L3

Maximum height difference between


outdoor unit and indoor units

30 m

30 m

30 m

Maximum height difference between indoor units

0.5 m

0.5 m

0.5 m

*1 .Max ( L1, L2 ) means maximum length out of L1 and L2.


*2 .Min ( L1, L2 ) means minimum length out of L1 and L2.

Refrigerant piping uses terminal branching to


facilitate installation.

(Branch piping kits are sold separatelly. Please use the indicated model on page.27)

L4,L5

50 m
20 m

L6

(For Double Twin Multi)

15

R50GV1K

R60GV1K

71
FHC71KVE
R71FUV1
R71FUY1

100
FHC100KVE
R100FUV1
R100FUY1

125
FHC125KVE

3.0/3.0
10.6/10.5
36,200/35,800
9,100/9,000
3.69/3.65
2.87/2.88

3.7/3.6
13.0/12.8
44,400/43,700
11,200/11,000
4.39/4.35
2.96/2.94

28/21
988/741
39/34
288X 840X 840

33/24
1,164/847
42/36
288X 840X 840

R125FUY1

1.5/1.5
5.34/5.3
18,200/18,100
4,590/4,560
2.02/2.01
2.64/2.64

1.8/1.8
6.44/6.4
22,000/21,800
5,540/5,500
2.45/2.44
2.63/2.62

15/11
529/388
33/29
230X 840X 840

19/14
670/494
35/30
230X 840X 840

2.2/2.2
7.8/7.7
26,600/26,300
6,700/6,600
2.60/2.58
3.00/2.98
White
19/14
670/494
35/30
230X 840X 840

40X 950X 950

40X 950X 950

40X 950X 950

40X 950X 950

40X 950X 950

24

24

24

28

28

kg

CWB

kW
kg

14 to 23

14 to 25

Ivory white
Hermetically sealed rotary type
1.7
2.2
1.20
1.50
(Charged for 10 m) (Charged for 5 m)

Hermetically sealed reciprocating type

2.2
2.1
(Charged for 5 m)

3.0
2.4
(Charged for 5 m)

3.75
2.8
(Charged for 5 m)

49
54
52
56
57
dBA
540X 750X 270
685X 800X 300
816X 880X 370
1,215X 880X 370
1,215X 880X 370
mm
kg
42
61
87 (V1),84 (Y1)
117 (V1),109 (Y1)
110
CDB
19.4 to 54
21 to 52
mm
o/ 6.4
o/ 6.4
o/ 9.5
o/ 9.5
o/ 9.5
mm
o/ 15.9
o/ 15.9
o/ 15.9
o/ 19.1
o/ 19.1
mm I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32
o/ 18.0 (Hole)
mm o/ 18.0 (Hole)
o/ 26.0 (Hole)
o/ 26.0 (Hole)
o/ 26.0 (Hole)
30
50 (equivalent length 70 m)
m
15
30
m
Both liquid and gas piping

Ceiling suspended type


Model
Name

Indoor unit
Outdoor unit

Cooling capacity
*1 (1)/(2)

50
FH50BVE

60
FH60BVE

R50GV1K

R60GV1K

71
FH71BVE
R71FUV1
R71FUY1

100
FH100BVE
R100FUV1
R100FUY1

125
FH125BVE

2.2/2.2
7.8/7.7
26,600/26,300
6,700/6,600
2.58/2.56
3.02/3.01
White
17/14
600/494
39/35
195X 1,160X 680
27

3.0/3.0
10.6/10.5
36,200/35,800
9,100/9,000
3.79/3.75
2.80/2.80

3.7/3.6
13.0/12.8
44,400/43,700
11,200/11,000
4.67/4.63
2.78/2.76

Sound level
*2
Dimensions (HX WX D)
Machine weight
Operation range
Piping
Liquid (Flare)
connections Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

R125FUY1

VE: 1 Phase, 220-240 V/220 V, 50/60 Hz V1: 1 Phase, 220-240 V, 50 Hz Y1: 3 Phase, 380-415 V, 50 Hz

Ton
kW
Btu/h
kcal/h
kW

1.5/1.4
5.19/5.1
17,700/17,400
4,460/4,400
2.16/2.15
2.40/2.37

1.9/1.8
6.6/6.5
22,500/22,200
5,690/5,600
2.8/2.78
2.36/2.34

Power consumption *1 (1)/(2)


COP *1 (1)/(2)
Colour
Indoor
13/10
16/13
m3/min
24/20
Air flow rate (H/L)
unit
458/353
564/458
cfm
847/706
38/33
38/33
42/37
Sound level (H/L) *2 dBA
195X 960X 680
195X 1,160X 680
195X 1,400X 680
Dimensions (HX WX D) mm
kg
24
26
32
Machine weight
CWB
14 to 23
14 to 25
Operation range
Ivory white
Colour
Outdoor
Hermetically sealed rotary type
Hermetically sealed reciprocating type
Compressor Type
unit
1.7
2.2
2.2
3.0
Motor output kW
1.20
1.50
2.1
2.4
kg
Refrigerant charge (R22)
(Charged for 10 m) (Charged for 5 m) (Charged for 5 m) (Charged for 5 m)

(For Triple Multi)

60
FHC60KVE

kg

Power supply

Outdoor unit

Triple Multi Operation

50 m

Remote
controller

Main pipe
L

Outdoor unit

Twin Multi Operation

Main
unit

L6

In case of L1

(For Twin Multi)

Unit
Decoration
panel

Note : An indoor unit's thermo-sensor must be used when the air conditioners
are controlled from another room.

Twin Multi Operation

L1

Machine
weight

Install the signal receiver unit (part of the optional wireless


remote controller) to turn an indoor unit into the master unit.

Piping Guideline

Distributed
piping kit

Ton
kW
Btu/h
kcal/h
kW

Power consumption *1 (1)/(2)


COP *1 (1)/(2)
Colour
Unit
Indoor
Decoration panel
unit
m3/min
Air flow rate (H/L)
cfm
Sound level (H/L) *2 dBA
mm
Dimensions Unit
(HX WX D) Decoration
mm
panel

Option

50
FHC50KVE

VE: 1 Phase, 220-240 V/220 V, 50/60 Hz V1: 1 Phase, 220-240 V, 50 Hz Y1: 3 Phase, 380-415 V, 50 Hz

Cooling capacity
*1 (1)/(2)

BRC7C613W

BRC1C61

Sub
unit

Outdoor unit

Option

BRC1C61

Note: Selectable thermo sensing is available with ceiling-mounted cassette


and ceiling-suspended models, but not with middle static-pressure
models.

Indoor unit

Power supply

INDOOR UNIT

Supports Two selectable thermo-sensor functions.

Ceiling mounted cassette type


Model
Name

Remote controllers for the Multi Series

A single remote controller controls simultaneous


operation of multiple indoor units.

SPECIFICATIONS

30/25
1,059/883
44/39
195X 1,590X 680
35

3.75
2.8
(Charged for 5 m)

dBA
49
54
52
56
57
mm
540X 750X 270
685X 800X 300
816X 880X 370
1,215X 880X 370
1,215X 880X 370
kg
42
61
87 (V1), 84 (Y1) 117 (V1), 109 (Y1)
110
CDB
19.4 to 54
21 to 52
mm
o/ 6.4
o/ 6.4
o/ 9.5
o/ 9.5
o/ 9.5
mm
o/ 15.9
o/ 15.9
o/ 15.9
o/ 19.1
o/ 19.1
mm I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26
mm o/ 18.0 (Hole)
o/ 18.0 (Hole)
o/ 26.0 (Hole)
o/ 26.0 (Hole)
o/ 26.0 (Hole)
m
30
50 (equivalent length 70 m)
m
15
30
Both liquid and gas piping

Notes) *1:Nominal cooling capacities are based on the following conditions:


(1)Return air temperature:27 CDB,19.5 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
(2)Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
*2:Anechoic chamber conversion value, measured under JIS conditions.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Capacities are net, including a deduction for cooling for indoor fan motor heat.

16

SPECIFICATIONS
Ceiling mounted cassette corner type

Model
Name
Power supply

45
FHK45FV1
R50GV1K

Indoor unit
Outdoor unit

Cooling capacity
*1 (1)/(2)

V1: 1 Phase, 220-240 V, 50 Hz

Ton
kW
Btu/h
kcal/h
kW

Power consumption
*1 (1)/(2)
COP
*1 (1)/(2)
Colour
Unit
Indoor
Decoration panel
unit
m3/min
Air flow rate (H/L)
cfm
Sound level (H/L)
*2 dBA
mm
Dimensions Unit
(HX WX D)
Decoration panel mm
kg
Machine
Unit
weight
kg
Decoration panel
CWB
Operation range
Colour
Outdoor
Compressor Type
unit
kW
Motor output
kg
Refrigerant charge (R22)
Sound level
*2 dBA
mm
Dimensions (HX WX D)
kg
Machine weight
CDB
Operation range
mm
Piping
Liquid (Flare)
connections
mm
Gas (Flare)
mm
Indoor unit
Drain
mm
Outdoor unit
m
Max. interunit piping length
m
Max. installation level difference
Heat insulation

60
FHK60FV1
R60GV1K

1.5/1.4
5.19/5.1
17,700/17,400
4,460/4,400
2.25/2.24
2.31/2.28
12/10
423/353
39/34
215X 1,110X 710
70X 1,240X 800
31
8.5

White

1.9/1.8
6.6/6.5
22,500/22,200
5,690/5,600
2.76/2.74
2.39/2.37
17/14
600/494
41/36
215X 1,310X 710
70X 1,440X 800
33
9.5

14 to 23
Ivory white
Hermetically sealed rotary type
1.7
2.2
1.20 (Charged for 10 m)
1.50 (Charged for 5 m)
49
540X 750X 270
42
o/ 6.4
o/ 15.9
I.D o/ 25X O.D o/ 32
o/ 18.0 (Hole)

19.4 to 54

Both liquid and gas piping

30
15

54
685X 800X 300
61
o/ 6.4
o/ 15.9
I.D o/ 25X O.D o/ 32
o/ 18.0 (Hole)

Ceiling mounted built-in type

Model
Name
Power supply
Cooling capacity
*1 (1)/(2)

45
FHB45FV1
R50GV1K

Indoor unit
Outdoor unit

V1: 1 Phase, 220-240 V, 50 Hz

Ton
kW
Btu/h
kcal/h
kW

Power consumption
*1 (1)/(2)
COP
*1 (1)/(2)
Colour
Unit
Indoor
Decoration panel
unit
m3/min
Air flow rate (H/L)
cfm
Sound level (H/L)
*2 dBA
mm
Dimensions Unit
(HX WX D)
Decoration panel mm
kg
Machine
Unit
weight
kg
Decoration panel
CWB
Operation range
Colour
Outdoor
Compressor Type
unit
kW
Motor output
kg
Refrigerant charge (R22)
Sound level
*2 dBA
mm
Dimensions (HX WX D)
kg
Machine weight
CDB
Operation range
mm
Piping
Liquid (Flare)
connections
mm
Gas (Flare)
mm
Indoor unit
Drain
mm
Outdoor unit
m
Max. interunit piping length
m
Max. installation level difference
Heat insulation

60
FHB60FV1
R60GV1K

1.5/1.4
5.19/5.1
17,700/17,400
4,500/4,400
2.33/2.32
2.23/2.20
14/10
494353
39/34
300X 700X 800
55X 880X 500
31
3.5

White

1.9/1.8
6.6/6.5
22,500/22,200
5,700/5,600
2.78/2.76
2.37/2.36
17/13
600/458
41/35
300X 1,000X 800
55X 1,100X 500
41
4.5

14 to 23
Ivory white
Hermetically sealed rotary type
1.7
2.2
1.20 (Charged for 10 m)
1.50 (Charged for 5 m)
49
540X 750X 270
42
o/ 6.4
o/ 15.9
I.D o/ 25X O.D o/ 32
o/ 18.0 (Hole)

19.4 to 54

Both liquid and gas piping

30
15

54
685X 800X 300
61
o/ 6.4
o/ 15.9
I.D o/ 25X O.D o/ 32
o/ 18.0 (Hole)

Wall mounted type


71
FA71FVEK
R71FUV1
R71FUY1

100
FA100FVEK
R100FUV1
R100FUY1

Ton
kW
Btu/h
kcal/h
kW

2.2/2.2
7.80/7.7
26,600/26,300
6,700/6,600
2.55/2.53
3.06/3.04

3.0/3.0
10.6/10.5
36,200/35,800
9,100/9,000
3.6/3.56
2.94/2.95

m3/min
cfm
*2 dBA
mm
kg
CWB

19/16
670/565
41/37
360X 1,570X 200
26

Indoor unit

Model
Name

Outdoor unit

Power supply

VE: 1 Phase, 220-240 V/220 V, 50/60 Hz V1: 1 Phase, 220-240 V, 50 Hz


Y1: 3 Phase, 380-415 V, 50 Hz

Cooling capacity
*1 (1)/(2)

Power consumption
COP
*1 (1)/(2)
Colour
Indoor
Air flow rate (H/L)
unit

Outdoor
unit

*1 (1)/(2)

Sound level (H/L)


Dimensions (HX WX D)
Machine weight
Operation range
Colour
Compressor Type
Motor output
Refrigerant charge (R22)

kW
kg

Sound level
*2 dBA
mm
Dimensions (HX WX D)
kg
Machine weight
CDB
Operation range
mm
Piping
Liquid (Flare)
connections
mm
Gas (Flare)
mm
Indoor unit
Drain
mm
Outdoor unit
m
Max. interunit piping length
m
Max. installation level difference
Heat insulation

White

14 to 25
Ivory white
Hermetically sealed reciprocating type
2.2
3.0
2.1 (Charged for 5 m)
2.4 (Charged for 5 m)
52
816X 880X 370
87 (V1), 84 (Y1)

21 to 52
o/ 9.5
o/ 15.9
I.D o/ 20X O.D o/ 26
o/ 26.0 (Hole)
50 (equivalent length 70 m)
30
Both liquid and gas piping

Model
Name

71
FV71LAVE
R71FUV1
R71FUY1

Indoor unit
Outdoor unit

Power supply

Cooling capacity
*1 (1)/(2)

100
FV100LAVE
R100FUV1
R100FUY1

125
FV125LAVE
R125FUY1

VE: 1 Phase, 220-240 V/220 V, 50/60 Hz V1: 1 Phase, 220-240 V, 50 Hz


Y1: 3 Phase, 380-415 V, 50 Hz

Ton
kW
Btu/h
kcal/h
kW

Sound level
*2 dBA
mm
Dimensions (HX WX D)
kg
Machine weight
CDB
Operation range
mm
Liquid (Flare)
Piping
connections
mm
Gas (Flare)
mm
Indoor unit
Drain
mm
Outdoor unit
m
Max. interunit piping length
m
Max. installation level difference
Heat insulation

2.2/2.2
7.80/7.7
26,600/26,300
6,700/6,600
2.67/2.65
2.92/2.91

52
816X 880X 370
87 (V1), 84 (Y1)

56
1,215X 880X 370
117 (V1), 109 (Y1)
21 to 52
o/ 9.5
o/ 9.5
o/ 15.9
o/ 19.1
I.D o/ 20X O.D o/ 26
I.D o/ 20X O.D o/ 26
o/ 26.0 (Hole)
o/ 26.0 (Hole)
50 (equivalent length 70 m)
30
Both liquid and gas piping

17

o/ 9.5
o/ 19.1
I.D o/ 20X O.D o/ 26
o/ 26.0 (Hole)

3.0/3.0
3.7/3.6
10.6/10.5
13.0/12.8
36,200/35,800
44,400/43,700
9,100/9,000
11,200/11,000
3.76/3.72
4.49/4.45
Power consumption
*1 (1)/(2)
2.82/2.81
2.9/2.88
COP
*1 (1)/(2)
White
Colour
Indoor
m3/min
18/14
28/22
32/25
Air flow rate (H/L)
unit
cfm
635/494
988/777
1,129/883
41/35
46/40
49/43
Sound level (H/L)
*2 dBA
mm
1,850X 600X 270
1,850X 600X 350
1,850X 600X 350
Dimensions (HX WX D)
kg
39
46
47
Machine weight
CWB
14 to 25
Operation range
Ivory white
Colour
Outdoor
Hermetically sealed reciprocating type
Compressor Type
unit
kW
2.2
3.0
3.75
Motor output
kg
2.1 (Charged for 5 m) 2.4 (Charged for 5 m) 2.8 (Charged for 5 m)
Refrigerant charge (R22)

56
1,215X 880X 370
117 (V1), 109 (Y1)

Floor standing type

Notes) *1:Nominal cooling capacities are based on the following conditions:


(1)Return air temperature:27 CDB,19.5 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
(2)Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
*2:Anechoic chamber conversion value, measured under JIS conditions.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Capacities are net, including a deduction for cooling for indoor fan motor heat.

Notes) *1:Nominal cooling capacities are based on the following conditions:


(1)Return air temperature:27 CDB,19.5 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
(2)Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
*2:Anechoic chamber conversion value, measured under JIS conditions.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Capacities are net, including a deduction for cooling for indoor fan motor heat.

24/20
847/706
45/41
360X 1,690X 200
27

18

57
1,215X 880X 370
110
o/ 9.5
o/ 19.1
I.D o/ 20X O.D o/ 26
o/ 26.0 (Hole)

SPECIFICATIONS
Duct connection middle static pressure type
Model
Name

Indoor unit
Outdoor unit

Power supply
Cooling capacity
*1 (1)/(2)
*3

Ton
kW
Btu/h
kcal/h
Power consumption *1 (1)/(2) kW
COP
*1 (1)/(2)
Colour
Indoor
m3/min
Air flow rate (H)
unit
cfm
Sound level (H/L) *2 dBA
mm
Dimensions (HX WX D)
kg
Machine weight
CWB
Operation range
Colour
Outdoor
Compressor Type
unit
Motor output
Refrigerant charge (R22)
Sound level
*2
Dimensions (HX WX D)
Machine weight
Operation range
Piping
Liquid (Flare)
connections Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

Model
Name

dBA
mm
kg
CDB
mm
mm

52
816X 880X 370
87(V1),84 (Y1)

o/ 9.5
o/ 15.9
3/4B
mm o/ 26.0 (Hole)
m
m

Power supply

140
FDMG140AV1

180
FDMG180AV1

R125FUY1

RG140AY1

RG180AY1

V1: 1 Phase, 220-240 V, 50 Hz Y1: 3 Phase, 380-415 V, 50 Hz

3.0/3.0
10.6/10.5
36,200/35,800
9,100/9,000
4.08/4.04
2.60/2.60

3.0
2.4(Charged for 5 m)

4.1/4.0
14.5/14.2
49,500/48,500
12,500/12,200
5.25/5.25
2.76/2.70

4.9/4.8
17.2/16.8
58,700/57,300
14,800/14,400
6.45/6.45
2.67/2.60

42
1,482
46/-
305X 1,550X 680
52

42
1,482
47/-
305X 1,900X 680
58

Hermetically sealed scroll type

3.75
4.50
4.50
2.8(Charged for 5 m) 2.9 (Charged for 5 m) 2.8 (Charged for 5 m)

56
57
1,215X 880X 370
1,215X 880X 370
117 (V1),109 (Y1)
110
21 to 52
o/ 9.5
o/ 9.5
o/ 19.1
o/ 19.1
3/4B
3/4B
o/ 26.0 (Hole)
o/ 26.0 (Hole)
50 (equivalent length 70 m)
30
Both liquid and gas piping

55
56
1,345X 880X 370
1,345X 880X 370
113
114
21 to 50
o/ 9.5
o/ 9.5
o/ 19.1
o/ 19.1
3/4B
3/4B
o/ 26.0 (Hole)
o/ 26.0 (Hole)

71
FDM03FAV1
R71FUV1
R71FUY1

100
FDM04FAV1
R100FUV1
R100FUY1

125
FDM05FAV1

2.2/2.2
7.8/7.7

3.0/3.0
10.6/10.5

3.7/3.6
13.0/12.8

R125FUY1

V1: 1 Phase, 220-240 V, 50 Hz Y1: 3 Phase, 380-415 V, 50 Hz

Cooling capacity
*1 (1)/(2)
*4

Ton
kW
Btu/h
kcal/h
Power consumption *1 (1)/(2) kW
COP
*1 (1)/(2)
Colour
Indoor
m3/min
Air flow rate (H)
unit
cfm
Fan Driving system
Sound level (H) *2 dBA
mm
Dimensions (HX WX D)
kg
Machine weight
CWB
Operation range
Colour
Outdoor
Compressor Type
unit

Sound level
*2
Dimensions (HX WX D)
Machine weight
Operation range
Piping
Liquid (Flare)
connections Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

125
FDMG125AV1

3.7/3.7
13.1/12.9
44,700/44,000
11,200/11,000
4.89/4.85
2.68/2.66
23
34
37
811
1,200
1,306
42/38
44/36
45/37
305X 1,350X 630
305X 1,550X 630
305X 1,550X 630
43
51
52
14 to 25
Ivory white
Hermetically sealed reciprocating type
2.2
2.4(Charged for 5 m)

Outdoor unit

100
FDMG100AV1
R100FUV1
R100FUY1

2.5/2.5
8.80/8.7
30,000/29,700
7,600/7,500
3.15/3.13
2.79/2.78

kW
kg

Indoor unit

Motor output
Refrigerant charge (R22)

71
FDMG71AV1
RG71AV1
RG71AY1

26,600/26,200
6,700/6,600

2.68/2.66
2.91/2.89

3.76/3.72
2.82/2.82
20
26
706
917
Direct drive (2 speed)
39
39
295X 1,100X 680
295X 1,500X 680
42
56
14 to 25
Ivory white
Hermetically sealed reciprocating type

kW
kg

2.2
2.1 (Charged for 5 m)

dBA
mm
kg
CDB
mm
mm

52
816X 880X 370
87 (V1), 84 (Y1)

mm
m
m

36,200/35,800
9,100/9,000

3.0
2.4 (Charged for 5 m)

56
1,215X 880X 370
117 (V1), 109 (Y1)
21 to 52
o/ 9.5
o/ 9.5
o/ 15.9
o/ 19.1
I.D o/ 25X O.D o/ 32
I.D o/ 25X O.D o/ 32
o/ 26.0 (Hole)
o/ 26.0 (Hole)
50 (equivalent length 70 m)
30
Both liquid and gas piping

Notes) *1:Nominal cooling capacities are based on the following conditions:


(1)Return air temperature:27 CDB,19.5 CWB, Outdoor temperature:35 CDB Equivalent ref. piping:5 m(Horizontal)
(2)Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB Equivalent ref. piping:5 m(Horizontal)
*2:Anechoic chamber conversion value, measured under JIS conditions.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
*3 Capacities are gross capacities which do not include a deduction for evaporator fan motor heat.
*4 Capacities are net, including a deduction for cooling for indoor fan motor heat.

The power consumption shown above is that of the outdoor unit only.
The power consumption of the indoor unit varies according to setup conditions, so refer to
the engineering data to obtain the relavant figure.

The above performance data based on the power supply of 220V.

44,400/43,700
11,200/11,000

4.50/4.46
2.89/2.87
35
1,235

44
295X 1,500X 680
57

3.75
2.8 (Charged for 5 m)
57
1,215X 880X 370
110
o/ 9.5
o/ 19.1
I.D o/ 25X O.D o/ 32
o/ 26.0 (Hole)

Duct connection low static pressure type


Model
Name

50
FDBG50AVE

Indoor unit

R50GV1K

Outdoor unit

Power supply
Ton
kW
Btu/h
kcal/h
kW

Power consumption *1 (1)/(2)


COP *1 (1)/(2)
Colour
Indoor
m3/min
Air flow rate (H/L)
unit
cfm
Fan Driving system
Sound level (H/L) *2 dBA
mm
Dimensions (HX WX D)
kg
Machine weight
CWB
Operation range
Colour
Outdoor
Compressor Type
unit
kW
kg

Motor output
Refrigerant charge (R22)
Sound level
*2
Dimensions (HX WX D)
Machine weight
Operation range
Liquid (Flare)
Piping
connections Gas (Flare)
Indoor unit
Drain
Outdoor unit

dBA
mm
kg
CDB
mm
mm
mm

Max. interunit piping length

Max. installation level difference


Heat insulation

1.5/1.5
5.34/5.30
18,200/18,100
4,590/4,560
2.06/2.05
2.59/2.59

2.0/2.0
7.03/6.97
24,000/23,800
6,050/6,000
2.76/2.75
2.55/2.53
18/15
635/529
Direct drive (2 speed)
42/39
260X 1,300X 580
31

13/11
458/388
41/38
260X 900X 580
23
14 to 23

Ivory white
Hermetically sealed rotary type

1.7
1.20 (Charged for 10 m)
49
540X 750X 270
42
19.4 to 54
o/ 6.4
o/ 15.9
3/4B
o/ 18.0 (Hole)

2.2/2.2
7.80/7.70
26,600/26,200
6,700/6,600
2.82/2.80
2.77/2.75
18/15
635/529

14 to 25

42/39
260X 1,300X 580
31

Hermetically sealed reciprocating type

2.2
1.50 (Charged for 5 m)

2.2
2.1 (Charged for 5 m)

54
685X 800X 300
61
19.4 to 46, (K)19.4 to 54
o/ 6.4
o/ 15.9
3/4B
o/ 18.0 (Hole)

52
816X 880X 370
87 (V1), 84 (Y1)
21 to 52
o/ 9.5
o/ 15.9
3/4B
o/ 26.0 (Hole)
50 (equivalent length 70 m)

30
15
Both liquid and gas piping

30

Duct connection high static pressure type

Model
Name
Power supply

Indoor unit
Outdoor unit

Cooling capacity
*1 (1)/(2)
*4

Ton
kW
Btu/h
kcal/h
kW

Power consumption *1 (1)/(2)


COP *1 (1)/(2)
Colour
Indoor
m3/min
Air flow rate (H/L)
unit
cfm
Fan Driving system
Sound level (H/L) *2 dBA
mm
Dimensions (HX WX D)
kg
Machine weight
CWB
Operation range
Colour
Outdoor
Compressor Type
unit
Motor output
Refrigerant charge (R22)
Sound level
*2
Dimensions (HX WX D)
Machine weight
Operation range
Liquid (Flare)
Piping
connections Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

71
FD03KY1
R71FUY1

100
FD04KY1
R100FUY1

125
FD05KY1
R125FUY1

V1: 1 Phase, 220-240 V, 50 Hz Y1: 3 Phase, 380-415 V, 50 Hz

2.3/2.2
8.1/7.9
27,600/27,000
7,000/6,800
2.5/2.48
3.24/3.19

3.1/3.1
4.0/3.9
11.0/10.8
14.0/13.8
37,500/36,800
47,800/47,100
9,500/9,300
12,000/11,800
3.52/3.48
4.19/4.15
3.13/3.10
3.34/3.33
26
30
46
917
1,059
1,623
Belt drive
46
49
49
450X 650X 850
450X 900X 850
450X 900X 850
51
59
72
14 to 25
Ivory white
Hermetically sealed reciprocating type

140
FD06KY1
RU06KY1
4.9/4.9
17.4/17.2
59,400/58,700
15,000/14,800
5.7/5.7
3.05/3.02
52
1,835
51
450X 1,130X 850
79

Hermetically sealed scroll type

kW
kg

2.2
2.1 (Charged for 5 m)

3.0
2.4 (Charged for 5 m)

3.75
2.8 (Charged for 5 m)

4.5
3.0 (Charged for 5 m)

dBA
mm
kg
CDB
mm
mm

52
816X 880X 370
84

56
1,215X 880X 370
109

57
1,215X 880X 370
110

59
1,345X 880X 320
112

mm
m
m

o/ 9.5
o/ 15.9
3/4B
o/ 26.0 (Hole)

21 to 52
o/ 9.5
o/ 9.5
o/ 19.1
o/ 19.1
3/4B
3/4B
o/ 26.0 (Hole)
o/ 26.0 (Hole)
50 (equivalent length 70 m)
30
Both liquid and gas piping

Notes) *1:Nominal cooling capacities are based on the following conditions:


(1)Return air temperature:27 CDB,19.5 CWB, Outdoor temperature:35 CDB Equivalent ref. piping:5 m(Horizontal)
(2)Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB Equivalent ref. piping:5 m(Horizontal)
*2:Anechoic chamber conversion value, measured under JIS conditions.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
*3 Capacities are net, including a deduction for cooling for indoor fan motor heat.
*4 Capacities are gross capacities which do not include a deduction for evaporator fan motor heat.

The power consumption shown above is that of the outdoor unit only.
The power consumption of the indoor unit varies according to setup conditions, so refer to
the engineering data to obtain the relavant figure.

The above performance data based on the power supply of 220V.


19

71
FDBG71AVE
R71FUV1
R71FUY1

VE: 1 Phase, 220-240 V/220 V, 50/60 Hz V1: 1 Phase, 220-240 V, 50 Hz Y1: 3 Phase, 380-415 V, 50 Hz

Cooling capacity
*1 (1)/(2)
*3

60
FDBG60AVE
R60GV1
R60GV1K

20

o/ 9.5
o/ 19.1
3/4B
-

SPECIFICATIONS

SPECIFICATIONS

Simultaneous operation system

Duct connection high static pressure type

Model
Indoor unit
Name
Outdoor unit
Power supply
Cooling capacity
Ton
kW
*1 (1)/(2)
Btu/h
kcal/h
kW
Power consumption *1 (1)/(2)
COP *1 (1)/(2)
Colour
Indoor
m3/min
Air flow rate (H/L)
unit
cfm
Fan Driving system
Sound level (H/L) *2 dBA
mm
Dimensions (HX WX D)
kg
Machine weight
CWB
Operation range
Colour
Outdoor
Compressor Type
unit
Motor output kW
kg
Refrigerant charge (R22)
Sound level
*2
Dimensions (HX WX D)
Machine weight
Operation range
Liquid (Flare)
Piping
connections Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

dBA
mm
kg
CDB
mm
mm

dBA
mm
kg
CDB
mm
mm

250
FD10KY1
RU10KUY1

400
FD15KY1
RU08KUY1x2

Y1: 3 Phase, 380-415 V, 50 Hz

500
FD20KY1
RU10KUY1x2

6.9/6.8
24.3/24.0
82,900/81,900
20,900/20,600
7.5/7.4
3.24/3.24

8.4/8.3
13.8/13.6
29.7/29.2
48.6/47.9
101,300/99,600
165,800/163,400
25,500/25,100
41,800/41,200
9.9/9.8
15.0/14.8
3.00/2.98
3.24/3.24
68
83
136
2,400
2,929
4,800
Belt drive
51
53
58
500X 1,130X 850
500X 1,330X 850
625X 1,620X 850
93
104
161
14 to 25
Ivory white
Hermetically sealed scroll type
7.5
9.0
7.5X 2
5.0
6.1
5.0 (Field charge
(Charged for 5 m)

(Charged for 5 m)

60
1,220X 1,280X 690
185
o/ 12.7
o/ 25.4

3/4B

200
FD08KY1
RU08KY1

16.8/16.6
59.3/58.4
202,300/199,300
51,000/50,200
19.8/19.6
2.99/2.89
166
5,859
60
625X 1,980X 850
187

9.0X 2
6.1 (Field charge

required for 5 m) X 2

61
60 *6
1,440X 1,280X 690
(1,220X 1,280X 690)X 2
200
185X 2
21 to 52
o/ 15.9
o/ 12.7X 2
o/ 31.8
o/ 25.4X 2

50 (equivalent length 70 m)
30
Both liquid and gas piping

mm
m
m

Model
Indoor unit
Name
Outdoor unit
Power supply
Cooling capacity
Ton
kW
*1 (1)/(2)
Btu/h
kcal/h
kW
Power consumption *1 (1)/(2)
COP *1 (1)/(2)
Colour
Indoor
m3/min
Air flow rate (H/L)
unit
cfm
Fan Driving system
Sound level (H/L) *2 dBA
mm
Dimensions (HX WX D)
kg
Machine weight
CWB
Operation range
Colour
Outdoor
Compressor Type
unit
Motor output kW
kg
Refrigerant charge (R22)
Sound level
*2
Dimensions (HX WX D)
Machine weight
Operation range
Liquid (Flare)
Piping
connections Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

200
FD08KY1
RU08KUY1

250
FD10KY1
RU10KY1

61 *6
(1,440X 1,280X 690)X 2
200X 2

1B

8.4/8.3
13.8/13.6
29.7/29.2
48.6/47.9
101,300/99,600
165,800/163,400
25,500/25,100
41,800/41,200
9.9/9.8
15.0/14.8
3.00/2.98
3.24/3.24
68
83
136
2,400
2,930
4,800
Belt drive
51
53
58
500X 1,130X 850
500X 1,330X 850
625X 1,620X 850
93
104
161
14 to 25
Ivory white
Hermetically sealed scroll type
7.5
9.0
7.5X 2
5.0 (Field charge
6.1 (Field charge
5.0 (Field charge
required for 5 m) *5

60
1,220X 1,280X 690
177
o/ 12.7
o/ 25.4

mm
m
m

3/4B

16.8/16.6
59.3/58.4
202,300/199,300
51,000/50,200
19.8/19.6
2.99/2.98
166
5,859
60
625X 1,980X 850
187

9.0X 2
6.1 (Field charge

required for 5 m) *3 X 2

61
60 *4
1,440X 1,280X 690
(1,220X 1,280X 690)X 2
190
177X 2
21 to 52
o/ 15.9
o/ 12.7X 2
o/ 31.8
o/ 25.4X 2

50 (equivalent length 70 m)
30
Both liquid and gas piping

Notes) *1:Nominal cooling capacities are based on the following conditions:


(1)Return air temperature:27 CDB,19.5 CWB, Outdoor temperature:35 CDB Equivalent ref. piping:5 m(Horizontal)
(2)Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB Equivalent ref. piping:5 m(Horizontal)
*2:Anechoic chamber conversion value, measured under JIS conditions.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Capacities are gross capacities which do not include a deduction for evaporator fan motor heat.
*3:This is the amount of refrigerant required for piping of five meters or less.
Since the unit does not contain refrigerant when shipped from the factory, it must be added at the installation site.
For details, please refer to the installation manual.
*4:Specification for outdoor unit is for a single unit only.

The power consumption shown above is that of the outdoor unit only.
The power consumption of the indoor unit varies according to setup conditions, so refer to

o/ 15.9X 2
o/ 31.8X 2

500
FD20KY1
RU10KY1x2

6.9/6.8
24.3/24.0
82,900/81,900
20,900/20,600
7.5/7.4
3.24/3.24

required for 5 m) *5

Ceiling mounted cassette type

Model
Name
Power supply

required for 5 m) *3 X 2

61 *4
(1,440X 1,280X 690)X 2
190X 2

1B

o/ 15.9X 2
o/ 31.8X 2

Indoor unit
Outdoor unit

200
FHYC100KVEX 2
R200KUY1

250
FHYC125KVEX 2
R250KUY1

6.4/6.3
22.5/22.2
76,800/75,700
19,400/19,100
7.7/7.6
2.92/2.92

7.7/7.6
27.1/26.6
92,500/90,800
23,300/22,900
9.7/9.7
2.79/2.74

VE: 1 Phase, 220-240 V/220 V, 50/60 Hz Y1: 3 Phase, 380-415 V, 50 Hz

Cooling capacity
*1 (1)/(2)

Ton
kW
Btu/h
kcal/h
Power consumption *1 (1)/(2) kW
*1 (1)/(2)
COP
Colour
Unit
Indoor
Decoration panel
unit
m3/min
Air flow rate (H/L)
*2
cfm
Sound level (H/L) *3 dBA
mm
Dimensions Unit
(HX WX D) Decoration
mm
panel
Machine
weight

required for 5 m) X 2

400
FD15KY1
RU08KY1x2

Y1: 3 Phase, 380-415 V, 50 Hz

TWIN & TRIPLE & DOUBLE TWIN MULTI

Unit
Decoration
panel

Model
Name
Power supply

40X 950X 950

28

28

kg

dBA
mm
kg
CDB
mm
mm
mm
mm
m
m

Indoor unit
Outdoor unit

5
14 to 25
Ivory white
Hermetically sealed scroll type

5.5
5.3 (Charged for 5 m)

9.0
5.7 (Charged for 5 m)

60
1,220X 1,280X 690
178

61
1,440X 1,280X 690
202

o/ 12.7
o/ 25.4 (Flange)
I.D o/ 25X O.D o/ 32
---------

-5 to 52

o/ 15.9
o/ 28.6 (Flange)
I.D o/ 25X O.D o/ 32
--------50 (equivalent length 70 m)
30
Both liquid and gas piping

200
FHYC71KVEX 3
R200KUY1

200
FHYC50KVEX 4
R200KUY1

250
FHYC60KVEX 4
R250KUY1

6.4/6.3
22.5/22.2
76,800/75,700
19,400/19,100
7.7/7.6
2.92/2.92

7.7/7.6
27.1/26.6
92,500/90,800
23,300/22,900
9.7/9.7
2.79/2.74

19/14
670/494
33/29
35/30
230X 840X 840

6.4/6.3
22.5/22.2
76,800/75,700
19,400/19,100
7.7/7.6
2.92/2.92
------------White
15/11
529/388
33/29
230X 840X 840

VE: 1 Phase, 220-240 V/220 V, 50/60 Hz Y1: 3 Phase, 380-415 V, 50 Hz

Ton
kW
Btu/h
kcal/h
Power consumption *1 (1)/(2) kW
COP
*1 (1)/(2)
Colour
Unit
Indoor
Decoration panel
unit
m3/min
Air flow rate (H/L)
*2
cfm
Sound level (H/L) *3 dBA
mm
Dimensions Unit
(HX WX D) Decoration
mm
panel
Unit
Decoration
panel

40X 950X 950

40X 950X 950

40X 950X 950

24

24

24

kg

14 to 25
Ivory white
Hermetically sealed scroll type
5.5
5.3 (Charged for 5 m)

9.0
5.7 (Charged for 5 m)

Operation range
Colour
Outdoor
Compressor Type
unit
Motor output
Refrigerant charge (R22)

CWB

kW
kg

5.5
5.3 (Charged for 5 m)

Sound level
*3
Dimensions (HX WX D)
Machine weight
Operation range
Piping
Liquid (Flare)
connections Gas
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

dBA
mm
kg
CDB
mm
mm
mm
mm
m
m

60
1,220X 1,280X 690
178
o/ 12.7
o/ 25.4 (Flange)
I.D o/ 25X O.D o/ 32
---------

60
1,220X 1,280X 690
178
-5 to 52
o/ 12.7
o/ 25.4 (Flange)
I.D o/ 25X O.D o/ 32
--------50 (equivalent length 70 m)
30
Both liquid and gas piping

21

Notes) *1:Nominal cooling capacities are based on the following conditions:


(1)Return air temperature:27 CDB,19.5 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
(2)Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
*2:Each value shows the specification per one unit.
*3:Anechoic chamber conversion value, measured under JIS conditions.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Capacities are net, including a deduction for cooling for indoor fan motor heat.
Models R200KU and R250KU are recommended for commercial facilities.

19/14
670/494
35/30
230X 840X 840

kg

the engineering data to obtain the relavant figure.

The above performance data based on the power supply of 220V.

33/24
1,164/847
42/36
288X 840X 840

40X 950X 950

Cooling capacity
*1 (1)/(2)

Machine
weight

28/21
988/741
39/34
288X 840X 840

kg

CWB
Operation range
Colour
Outdoor
Compressor Type
unit
Motor output kW
kg
Refrigerant charge (R22)

Sound level
*3
Dimensions (HX WX D)
Machine weight
Operation range
Liquid (Flare)
Piping
connections Gas
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

------------White

22

61
1,440X 1,280X 690
202
o/ 15.9
o/ 28.6 (Flange)
I.D o/ 25X O.D o/ 32
---------

SPECIFICATIONS
Simultaneous operation system

TWIN & TRIPLE & DOUBLE TWIN MULTI


Ceiling suspended type

Model
Name
Power supply

Indoor unit
Outdoor unit

Ton
kW
Btu/h
kcal/h
Power consumption *1 (1)/(2) kW
COP *1 (1)/(2)
Colour
Indoor
m3/min
Air flow rate (H/L)
unit
cfm
*2
Sound level (H/L) *3 dBA
Dimensions (HX WX D) mm
kg
Machine weight
CWB
Operation range
Colour
Outdoor
Compressor Type
unit
Motor output kW
kg
Refrigerant charge (R22)
Cooling capacity
*1 (1)/(2)

Sound level (380 V) *3


Dimensions (HX WX D)
Machine weight
Operation range
Piping
Liquid (Flare)
connections Gas
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

Model
Name
Power supply

dBA
mm
kg
CDB
mm
mm
mm
mm
m
m

Indoor unit
Outdoor unit

Ton
kW
Btu/h
kcal/h
Power consumption *1 (1)/(2) kW
COP *1 (1)/(2)
Colour
Indoor
m3/min
Air flow rate (H/L)
unit
cfm
*2
Sound level (H/L) *3 dBA
Dimensions (HX WX D) mm
kg
Machine weight
CWB
Operation range
Colour
Outdoor
Compressor Type
unit
Motor output kW
kg
Refrigerant charge (R22)
Cooling capacity
*1 (1)/(2)

Sound level (380 V) *3


Dimensions (HX WX D)
Machine weight
Operation range
Piping
Liquid (Flare)
connections Gas
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

dBA
mm
kg
CDB
mm
mm
mm
mm
m
m

200
FHY100BVEX 2
R200KUY1

250
FHY125BVEX 2
R250KUY1

6.4/6.3
22.5/22.2
76,800/75,700
19,400/19,100
7.7/7.6
2.92/2.92
White
24/20
847/706
42/37
195X 1,400X 680
32

7.7/7.6
27.1/26.6
92,500/90,800
23,300/22,900
9.7/9.7
2.79/2.74
30/25
1,059/833
44/39
195X 1,590X 680
35

5.5
5.3 (Charged for 5 m)

9.0
5.7 (Charged for 5 m)

60
1,220X 1,280X 690
178

61
1,440X 1,280X 690
202

VE: 1 Phase, 220-240 V/220 V, 50/60 Hz Y1: 3 Phase, 380-415 V, 50 Hz

14 to 25
Ivory white
Hermetically sealed scroll type

o/ 12.7
o/ 25.4 (Flange)
I.D o/ 20X O.D o/ 26
---------

200
FHY71BVEX 3
R200KUY1

-5 to 52

o/ 15.9
o/ 28.6 (Flange)
I.D o/ 20X O.D o/ 26
--------50 (equivalent length 70 m)
30
Both liquid and gas piping
200
FHY50BVEX 4
R200KUY1

250
FHY60BVEX 4
R250KUY1

VE: 1 Phase, 220-240 V/220 V, 50/60 Hz Y1: 3 Phase, 380-415 V, 50 Hz

6.4/6.3
22.5/22.2
76,800/75,700
19,400/19,100
7.7/7.6
2.92/2.92
17/14
600/494
39/35
195X 1,160X 680
27

5.5
5.3 (Charged for 5 m)
60
1,220X 1,280X 690
178
o/ 12.7
o/ 25.4 (Flange)
I.D o/ 20X O.D o/ 26
---------

6.4/6.3
22.5/22.2
76,800/75,700
19,400/19,100
7.7/7.6
2.92/2.92
White
13/10
458/353
38/33
195X 960X 680
24
14 to 25
Ivory white
Hermetically sealed scroll type
5.5
5.3 (Charged for 5 m)
60
1,220X 1,280X 690
178
-5 to 52
o/ 12.7
o/ 25.4 (Flange)
I.D o/ 20X O.D o/ 26
--------50 (equivalent length 70 m)
30
Both liquid and gas piping

7.7/7.6
27.1/26.6
92,500/90,800
23,300/22,900
9.7/9.7
2.79/2.74
16/13
564/459
38/33
195X 1,160X 680
26

Duct connection middle static pressure type

Model
Name
Power supply

Indoor unit
Outdoor unit

Cooling capacity
*1 (1)/(2)

250
FDYM05FAV1X 2
R250KUY1

Ton
kW
Btu/h
kcal/h
kW

dBA
mm
kg
CDB
mm
mm
mm
m
m

6.4/6.3
22.5/22.2
76,800/75,700
19,400/19,100
7.7/7.6
2.92/2.92

7.7/7.6
27.1/26.6
92,500/90,800
23,300/22,900
9.7/9.7
2.79/2.74
---------26
35
917
1,235
98(10)
98(10)
Direct drive (2 speed)
39
44
295X 1,500X 680
295X 1,500X 680
56
57
14 to 25
Ivory white
Hermetically sealed scroll type
5.5
9.0
5.3 (Charged for 5 m)
5.7 (Charged for 5 m)
60
1,220X 1,280X 690
178
o/ 12.7
o/ 25.4
I.D o/ 25X O.D o/ 32
---------

61
1,440X 1,280X 690
202
-5 to 52
o/ 15.9
o/ 28.6
I.D o/ 25X O.D o/ 32
--------50 (equivalent length 70 m)
30
Both liquid and gas piping

Notes) *1:Nominal cooling capacities are based on the following conditions:


(1)Return air temperature:27 CDB,19.5 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
(2)Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
*2:Each value shows the specification per one unit.
*3:Anechoic chamber conversion value, measured under JIS conditions.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Capacities are net, including a deduction for cooling for indoor fan motor heat.
The power consumption shown above is that of the outdoor unit only.
The power consumption of the indoor unit varies according to setup conditions, so refer to
the engineering data to obtain the relavant figure.
Air flow rate and sound pressure level are shown at 220V(380V)-240V(415V)
Models R200KU and R250KU are recommended for commercial facilities.

9.0
5.7 (Charged for 5 m)
61
1,440X 1,280X 690
202
o/ 15.9
o/ 28.6 (Flange)
I.D o/ 20X O.D o/ 26
---------

Notes) *1:Nominal cooling capacities are based on the following conditions:


(1)Return air temperature:27 CDB,19.5 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
(2)Return air temperature:27 CDB,19.0 CWB, Outdoor temperature:35 CDB
Equivalent ref. piping:5 m(Horizontal)
*2:Each value shows the specification per one unit.
*3:Anechoic chamber conversion value, measured under JIS conditions.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Capacities are net, including a deduction for cooling for indoor fan motor heat.
Models R200KU and R250KU are recommended for commercial facilities.

23

200
FDYM03FAV1X 3
R200KUY1

V1: 1 Phase, 220-240 V, 50 Hz Y1: 3 Phase, 380-415 V, 50 Hz

Power consumption *1 (1)/(2)


COP *1 (1)/(2)
Colour
Indoor
m3/min
Air flow rate (H)
unit
cfm
*2
Fan External static pressure Pa(mmH2O)
Driving system
Sound level (H) *3 dBA
Dimensions (HX WX D) mm
kg
Machine weight
CWB
Operation range
Colour
Outdoor
Compressor Type
unit
Motor output kW
kg
Refrigerant charge (R22)
Sound level (380 V) *3
Dimensions (HX WX D)
Machine weight
Operation range
Piping
Liquid (Flare)
connections Gas (Flange)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

200
FDYM04FAV1X 2
R200KUY1

24

6.4/6.3
22.5/22.2
76,800/75,700
19,400/19,100
8.0/7.9
2.81/2.81
20
706
98(10)
39
295X 1,100X 680
42

5.5
5.3 (Charged for 5 m)
60
1,220X 1,280X 690
178
o/ 12.7
o/ 25.4
I.D o/ 25X O.D o/ 32
---------

OPTIONS

Name of option

Ceiling mounted cassette type


Remark

Kit name
FH(Y)C5071K

Decoration panel
Sealing member of air discharge outlet
Panel spacer
Without T joint
Fresh air
pipe and fan
Chamber
intake kit
type
With T joint
*1
pipe,without fan
Direct installation type
Chamber connection kit *2
High-efficiency filter (Colorimetric method 65%)
(Colorimetric method 90%)
Replacement high- (Colorimetric method 65%)
efficiency filter
(Colorimetric method 90%)
High-efficiency filter chamber
Replacement long-life filter
Ultra-long life filter
Replacement ultra-long life filter
Branch duct chamber
Wired type *3
Remote controller
Wireless type
Set back time clock
Central remote controller *4
Unified ON/OFF controller *4
Schedule timer *4
intelligent Touch Controller *4
Adaptor for wiring *5
Wiring adaptor for electrical appendices *5
Interface adaptor for SkyAir series
Installation box for adaptor PCB

FH(Y)C100/125K

BYC125K-W1
KDBHJ55K160
KDBP55H160WA
KDDP55D160
KDDP55D160K

KAFP556D80
KAFP557D80
KAFP552H80
KAFP553H80

KDJ55K80

KDDJ55X160
KKSJ55K160

KDDFP55D160
KAFJ551K160
KAFP55D160
KAFJ55K160H
BRC1C61
BRC7C613W
BRC15A61
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP1B57
KRP4A53
DTA102A52
KRP1B98

KAFP556D160
KAFP557D160
KAFP552H160
KAFP553H160

Ceiling mounted cassette corner type

Name of option

KDJ55K160

Ceiling mounted built-in type

Flexible duct

Direct installation type


Kit name: KDDJ55X160
Flexible duct

(to be procured at a local outlet)

T joint pipe

T joint pipe

(to be procured at a local outlet)

(Colorimetric method 65%)


(Colorimetric method 90%)
Replacement long-life filter Resin net
Filter chamber for bottom suction
Filter chamber for rear suction
Canvas duct
(o/ 150)
Discharge grille
(o/ 200)
(o/ 150)
Discharge chamber
(o/ 200)
Branch duct
o/ 200 o/ 150
(o/ 150)
Flexible duct
(o/ 200)

Duct flange

(with insulation material)

Suction chamber
Connection chamber

Intake duct

(to be procured at a local outlet)

Intake duct (to be procured at a local outlet)

(Duct length: 4 m Max.)

Figure 1)

(Duct length: 4 m Max.)

Signal receiver
unit

Refrigerant piping

Notes: R equires an inspection port for maintenance


access.
If intake ducts cannot be connected to both
connection chambers due, for example, to an
obstruction, single intake duct installation is
possible.
Figure 1 shows what the installation will look
like when the signal receiver unit for the
wireless remote controller is installed.

Remark

Decoration panel
Service access panel
High-efficiency filter

Chamber type
(with the T joint pipe and without fan)
Kit name:KDDP55D160K

Intake duct (to be procured at a local outlet)

KRP1C93

Kit name

FHK45F
BYK45FJW1
KPBJ52F56W
KDBJ52F56W
KAFJ521F56
K-HV7AW
KFDJ52F56

BRC1C61
BRC15A61
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP1B51
KRP4A51
DTA102A52

FHK60F
BYK71FJW1
KPBJ52F80W
KDBJ52F80W
KAFJ521F80
K-HV9AW
KFDJ52F80

Note : *1: Wire for remote controller is field supply.


*2: This optional accessory requires DTA102A52.

Three types of fresh air intake kits are available.

Connection chamber

Remark

Decoration panel
Panel spacer
Air discharge blind panel
Replacement long-life filter Resin net
Discharge grille
Flexible duct with shutter
Remote controller
Wired type *1
Set back time clock
Central remote controller *2
Unified ON/OFF controller *2
Schedule timer *2
intelligent Touch Controller *2
Adaptor for wiring (Interlock for fresh air intake fan)
Wiring adaptor for electrical appendices
Interface adaptor for SkyAir series

Name of option

Suction chamber

Kit name
FH(Y)50B FH(Y)60B FH(Y)71B FH(Y)100B FH(Y)125B
KAFJ501D56
KAFJ501D80
KAFJ501D112 KAFJ501D160
KDU50B50VE
KDU50B71VE
KDU50B125VE
KHFJ5F60
KHFJ5F80
KHFJ5F160
BRC1C61
BRC7EA66
BRC15A61
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP1B54
KRP4A52
DTA102A52
KRP1C93

Note : *1: Wire for remote controller is field supply.


*2: This optional accessory requires DTA102A52.
*3: Installation box for adaptor PCB (KRP1C93) is necessary.

Note : *1:For details please refer to the diagram below.


*2:Necessary when installing the fresh air intake kit with high-efficiency filter or, ultra long-life filter.
*3:Wire for remote controller is field supply.
*4:This optional accessory requires DTA102A52.
*5:Installation box for adaptor PCB (KRP1B98) is necessary.

Chamber type
(without the T joint pipe and fan)
Kit name: KDDP55D160

Remark

Replacement long-life filter Resin net


Drain up kit
L-type piping kit (for upward direction)
Remote controller
Wired type *1
Wireless type
Set back time clock
Central remote controller *2
Unified ON/OFF controller *2
Schedule timer *2
intelligent Touch Controller *2
Adaptor for wiring
Wiring adaptor for electrical appendices *3
Interface adaptor for SkyAir series
Installation box for adaptor PCB

Indoor unit

Name of option

Indoor unit

Ceiling suspended type

Notes: R equires an inspec tion port for


maintenanc e ac c ess.
For dual intake duc t installation only. If
only a single intake duc t c an be
c onnec ted bec ause of an obstruc tion,
etc ., K DDP55D160 should be used
instead.
It is not possible to use this kit
simultaneously with the wireless remote
c ontroller.

KDDP55D160

The fresh air intake kit may or may not be usable depending on the ceiling structure and the
use of other optional items.
Be sure to check before starting the installation

Blind board
Adaptor for discharge
Flange for suction
Remote controller
Wired type *1
Set back time clock
Central remote controller *2
Unified ON/OFF controller *2
Schedule timer *2
intelligent Touch Controller *2
Adaptor for wiring (Interlock for fresh air intake fan)
Wiring adaptor for electrical appendices
Interface adaptor for SkyAir series

FHB45F
BYBS45DJW1
KTBJ25K56W
KAFJ252L56
KAFJ253L56
KAFJ251K56
KAJ25L56D
KAJ25L56B
KSA-25K56
K-DG4DW
K-DG7DW
K-DGC4D
K-DGC7D

K-FDS151D (1 m)
K-FDS154D (4 m)
K-FDS201D (1 m)
K-FDS204D (4 m)

K-DDV20A
K-FDS152D (2 m)
K-FDS155D (5 m)
K-FDS202D (2 m)
K-FDS205D (5 m)

KBBJ25K56
KDAJ25K56
KDJ2507K56

BRC1C61
BRC15A61
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP1B54
KRP4A51
DTA102A52

FHB60F
BYBS71DJW1
KTBJ25K80W
KAFJ252L80
KAFJ253L80
KAFJ251K80
KAJ25L80D
KAJ25L80B
KSA-25K80
K-DG5DW
K-DG9DW
K-DGC5D
K-DGC9D
K-FDS153D (3 m)
K-FDS156D (6 m)
K-FDS203D (3 m)
K-FDS206D (6 m)
KBBJ25K80
KDAJ25K71
KDJ2507K80

Note : *1: Wire for remote controller is field supply.


*2: This optional accessory requires DTA102A52.

Wall mounted type

Name of option

Remark

Remote controller

Wired type *1
Wireless type

Set back time clock


Central remote controller *2
Unified ON/OFF controller *2
Schedule timer *2
intelligent Touch Controller *2
Wiring adaptor for electrical appendices
Interface adaptor for SkyAir series

Note : *1: Wire for remote controller is field supply.


*2: This optional accessory requires DTA102A52.

25

Kit name

Kit name

FA71F

BRC1C61
BRC7C69W
BRC15A61
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP4A51
DTA102A52

26

FA100F

OPTIONS

Indoor unit

Floor standing type

Name of option

Remark

Kit name

Replacement long-life filter


Set back time clock
Central remote controller *1
Unified ON/OFF controller *1
Schedule timer *1
intelligent Touch Controller *1
Remote controller for 2 remote control system
Adaptor for wiring *2
Wiring adaptor for electrical appendices *2
Interface adaptor for SkyAir series
Installation box
For wiring adaptor for
for adaptor PCB
electrical appendices

FV71125LA
KAFJ95L160
BRC15A61
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
BRC1C61
KRP1B57
KRP4A52
DTA102A52
KRP4A95

Note : *1: This optional accessory requires DTA102A52.


*2: Installation box for adaptor PCB (KRP4A95) is necessary.

Duct connection middle static pressure type

Name of option

Remark

Remote controller
Digital remote controller
Digital remote controller With swich for duct heater
Wired type
Remote controller
Wireless type
Set back time clock
Central remote controller *1
Unified ON/OFF controller *1
Schedule timer *1
intelligent Touch Controller *1
Wiring adaptor for electrical appendices *2
Interface adaptor for SkyAir series
Note : *1: This optional accessory requires DTA102A52.
*2: Installation box for adaptor PCB (KRP4A95) is necessary.

FD(Y)M0305FA
------------------BRC1C61
BRC4C64
BRC15A61
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP4A51
DTA102A52

Duct connection low static pressure type

Name of option

Remark

Remote controller with 3 minute timer


Digital remote controller with 3 minute timer
Digital remote controller With swich for duct heater
with 3 minute timer
Suction grille
Drain pan cover

Kit name
FDMG71180A
KRC47-1
KRC47-2
KRC47-4
-------------------------------------------------------

Kit name
FDBG2550K

KRC47-1
KRC47-2

FDBG60/71K

KRC47-4
KDGF19A45

KKD19A1

KDGF19A71

Duct connection high static pressure type

Name of option

Remark

Remote controller *1
Digital remote controller *1
Central remote controller *2
Unified ON/OFF controller *2
Schedule timer *2
intelligent Touch Controller *2
Remote sensor
Central control adaptor kit

Kit name
FD0310K
KRC47-3

FD15/20K
KRC47-3 / KRC17-2B *3
KRC47-5
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRCS01-1
DTA107A55

Note : *1: Wire for remote controller is field supply.


*2: This optional accessory requires DTA107A55
*3: In case of using KRC17-2B or field supplied remote controller, Three-Minutes Timer (field supplied) is required.

Outdoor unit
Name of option

Remark

Drain piping kit


Central drain plug

Name of option

Remark

Refrigerant branch piping For twin multi


For triple multi
For double twin multi

Kit name
R50/60G
KIS95
-------

R71125FU

RG71/140/180A
------KKPJ5F180

Kit name
R200KU
KHD58C23A
KHR58P322H
KHRJ5F224F

R250KU
KHD58C24A
------KHRJ5F280F

27

OPTIONS

New communication functions in the user-friendly icon based multilingual


controller simplity centralized control of the system

New
Function 1

Doubling of number of connectable indoor


unit by adding a D -NET PLUS adapter (Optional)

New
Function 2

Support for centralized control from else


where., using a PC with a Web browser (Optional)

New
Function 3

Sending of e-mail alerts to a specified


address when malfunctions occur (Optional)

New
Function 4

Built-in Ethernet port for connecting to


the Internet or an intranet

New
Function 5

Up gr a d e

Simple interlock function

Yearly schedule
Power proportional distribution* (option)
Auto cool/heat change-over
Temperature Limitation

CSV output of
power proportional distribution
results (Optional)

DCS601C51

PCMCIA
Flash
Memory

Unification adapter
for computerized
control
[DCS302A52]

New
Function 2

New
Function 4

Remote monitoring and control

Unified ON/OFF
and status monitoring
from the central
monitoring panel

Forced OFF
contact input
Pi Port
Connection to power consumption meter
when using power proportional
distribution function. (Optional)

Trouble reports

New
Function 3

Forced OFF
command from
fire alarm
monitoring panel

RS-232C

Labor saving Overall energy savings


Simplified BMS

Color LCD Touch panel Icon display


Multilingual (English, French, German, Spanish,
Italian, or Chinese)

* Limitations apply to some models and functions. For details


please contact your local sales office.

D -NET Plus Adapter


(option)[DCS601A52]

New
Function 3
Trouble
reports

Indoor Unit

HRV

New
Function 1

Number of indoor unit expanded from 64 to 128.

Mobile Phone

Necessary for optional interface adaptor for SkyAir series (DTA102A52) with the Intelligent Touch Controller.

Many options are available for use with large-scale and


advanced-function centrally controlled systems
Central remote controller

DCS302CA61

Centralized control, with setting as simple


as it is with a standard remote controller,
of up to 64 groups (1,024 indoor units) is
possible.

Wiring adaptor for electrical appendices

Unified ON/OFF controller

DCS301BA61

Centralized control of on/off by group or all


at once for up to 256 indoor units.

DST301BA61

Unified control of weekly schedule for up to


1,024 indoor units.
Schedule timer sets on/off time in 1 minute units to be
executed twice a day for units of 1 week each.

Interface adaptor
for SkyAir series

Central control
adaptor kit

DTA102A52

DTA107A55

KRP4A51 KRP4A52 KRP4A53

For connecting to a central monitoring


panel to enable discrete, group, and zone
control operations.

Schedule timer

For connecting to a centralized control system that is


made with the high-speed DIII-NET communication
system that has been adopted for the Daikin VRV System.
To use the above optional remote controllers, these adaptors are
required on the main unit side of the air conditioner.
The central control adaptor kit for the duct connection low static
pressure type (FDB) can be made-to-order.

28