You are on page 1of 62

Siemens AG 2013

Switching Devices Contactors


and Contactor Assemblies
Contactor Relays and Relays

Price groups
PG 41A, 41B, 41H, 4N1

5/4
5/15
5/16
5/24

5/32

5/35
5/37

Introduction
Contactor relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole
SIRIUS 3RH24 latched contactor relays,
4-pole
3TH4 contactor relays,
8- and 10-pole
3TH2 contactor relays,
4- and 8-pole
Coupling contactors
SIRIUS 3RH21 coupling contactors for
switching auxiliary circuits, 4-pole
Contactors with extended
operating range 0.7 ... 1.25 Us
for railway applications
SIRIUS 3RH21 contactor relays
3TH4 contactor relays

5/53

Coupling relays
3TX7 coupling relays, narrow design
Relay couplers
Relay couplers with plug-in design
Semiconductor couplers
SIRIUS 3RS18 coupling relays
with industrial enclosure
Relay couplers
Coupling relays with
LZS/LZX plug-in relays
Plug-in relay couplers

Ch.4

Power relays/Miniature contactors


3TG10 contactors, 4-pole, 4 kW

5/39
5/44
5/47

5/51

Notes:
3RH1 contactor relays can be found
- in the Catalog Add-On
IC 10 AO 2014 in the DVD box IC 01
- in the Catalog Add-On
IC 10 AO 2014 at the Information
and Download Center
- in the interactive catalog CA 01
- in the Industry Mall
Conversion tool
e.g. from 3RH11 to 3RH21 see
www.siemens.com/sirius/conversion-tool

Siemens
Siemens
IC 10
IC 10
2014
2014

5/2

Siemens AG 2013

Switching Devices Contactors and Contactor Assemblies


Contactor Relays and Relays
Introduction

Overview
The advantages at a glance

Size
Type

S00
3RH21

S00
3RH22

3TH42

3TH43

3TH2

Article No.

Page

3RH21

5/10, 5/11

8-pole

3RH22

5/10, 5/11

4-pole, latched

3RH24

5/15

3RH2 contactor relays


Screw terminals, spring-type terminals and
ring terminal lug connections

4-pole

Coupling contactors

Coils for control by PLC

3RH21

5/32

Contactor relays
for railway applications

Coils with extended voltage range

3RH21

5/35

Screw terminals

3TH42

5/20

3TH43

5/21

Coils with extended voltage range

3TH42

5/37

4-pole

Screw terminals, flat connectors and solder pin connections

3TH20

5/28

8-pole

Screw terminals

3TH22

5/28

4-pole, latched

Screw terminals

3TH27

5/28

On front

3RH2911

5/12

Lateral

3RH2911

Chapter 3

Delayed, on front

3RA28

Chapter 3

Timing relay blocks

On front

3RA281.

Chapter 3

Surge suppressors

On front

3RT2916

5/13

Additional load module

On front

3RT2916

5/13

3TH4 contactor relays


8-pole
10-pole
Contactor relays for
railway applications

3TH2 contactor relays

Accessories for 3RH2 contactor relays


Auxiliary switch blocks

Note:
Safety characteristics for contactors see Chapter 16,
"Appendix" "Standards and Approvals" "Overview".

5/2

Siemens IC 10 2014

Siemens AG 2013

Switching Devices Contactors and Contactor Assemblies


Contactor Relays and Relays
Introduction

The advantages at a glance

Type

3TX7002

3TX7014

3RS18

LZS/LZX

3TG10

Article No.

Page

Width 11.5 mm (1 NO), 17.5 mm (1 CO) or


22.5 mm (2 NO, 2 CO)

3TX7002,
3TX7003

5/39

Width 6.2 mm (1 NO, 1 CO) or


12.5 mm (1 CO)

3TX7004,
3TX7005

Relay couplers

Coupling links, narrow design

Output coupling links


Input coupling links with hard gold-plating
Plug-in base couplers, complete with relay

Width 6.2 mm (1 NO, 1 CO)


Relays, replaceable

3TX7014-1..00;
3TX7015-1..00

5/44

Plug-in base couplers, complete with relay


and hard gold-plating

Width 6.2 mm (1 CO)

3TX7014-1..02;
3TX7015-1..02

5/44

Semiconductor couplers

Output 1 semiconductor, triac or transistor,


width 6.2, 11.5 and 12.5 mm

3TX7002,
3TX7004,
3TX7005

5/47

Protective separation up to 300 V between


contacts and relay circuits
1, 2 or 3 changeover contacts
Hard gold-plated contacts in combination
and wide voltage range versions

3RS18

5/51

Plug-in relay couplers with 2, 3 and 4 changeover


contacts

Switching capacity 12 A/10 A/6 A


Width 27 mm
Base with or without logical separation

LZS/LZX:PT

5/53

Plug-in relay couplers with 3 changeover contacts and


circular base

Switching capacity 10 A
11-pole circular base
Width 38 mm

LZS/LZX:MT

5/59

Plug-in relay couplers with 1 or 2 changeover contacts

Switching capacity 16 A/8 A


Width 15.5 mm
Base with or without logical separation

LZS/LZX:RT

5/60

Switching capacity 20 A (AC-1) or


8.4 A (AC-2, AC-3)
4-pole, hum-free
Width 36 mm

3TG10

Ch. 4

Coupling relays in industrial enclosure


Relay couplers

Coupling relays with plug-in relays

Miniature contactors (power relays)


With screw and flat connectors

Connection methods
The contactor relays and the relays are available with screw
terminals (box terminals) or with spring-type terminals.

Screw terminals

Devices of the 3TH2 series are also available for connection with
flat connectors and solder pin connectors.

Spring-type terminals

The plug-in bases for LZS/LZX coupling relays are also available
with plug-in terminals.

Flat connectors

As an option the devices of the 3RH2 series are also available


for connection with ring terminal lugs, particularly versions for
North America and Japan.

Solder pin connections


Plug-in terminals
Ring terminal lug connections
The terminals are indicated in the corresponding
tables by the symbols shown on orange backgrounds.

Siemens IC 10 2014

5/3

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole

Overview
Contactor relays and coupling relays
Size S00 with accessories

10

1
11

11
10

2
6

12
7

NSB0_02058

11
8
13
9

1 Contactor relay
2 Coupling relay for auxiliary circuits
3 Solid-state timing relay block
4 1-pole auxiliary switch block, cable entry from the top
5 2-pole auxiliary switch block, cable entry from the top
6 1-pole auxiliary switch block, cable entry from the bottom

7 2-pole auxiliary switch block, cable entry from the bottom


8 4-pole auxiliary switch block
(terminal designations according to EN 50011 or EN 50005)
9 2-pole auxiliary switch block, solid-state compatible version
(terminal designations according to EN 50005)
10 Solder pin adapter for contactor relays with 4-pole auxiliary switch block
11 Solder pin adapter for contactor and coupling relays
12 Additional load module for increasing the permissible residual current
13 Surge suppressor with LED
14 Surge suppressor without LED

5/4

Siemens IC 10 2014

14

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole
Standards

Auxiliary switch blocks

IEC 60947-1, EN 60947-1,


IEC 60947-4-1, EN 60947-4-1,
IEC 60947-5-1, EN 60947-5-1

The 3RH21 contactor relays can be expanded by up to four contacts by the addition of snap-on auxiliary switch blocks.

The 3RH2 contactor relays have screw, ring terminal lug or


spring-type terminals. The basic unit contains four contacts with
terminal designations according to EN 50011.
The 3RH2 contactor relays are suitable for use in any climate.
They are finger-safe according to EN 50274. The devices with
ring terminal lug connection comply with degree of protection
IP20 when fitted with the related terminal cover.

The auxiliary switch block can easily be snapped onto the front
of the contactor relays. The auxiliary switch block has a centrally
positioned release lever for disassembly.
Auxiliary switches according to EN 50011

Contact reliability
High contact stability at low voltages and currents, suitable for
solid-state circuits with currents 1 mA at a voltage of 17 V.
Surge suppression
RC elements, varistors, diodes or diode assemblies (combination of a diode and a Zener diode) can be plugged onto all 3RH2
contactor relays from the front for damping opening surges in
the coil. The plug-in direction is determined by a coding device.
Note:
The OFF-delay of the NO contact and the ON-delay of the
NC contact are increased if the contactor coils are attenuated
against voltage peaks (noise suppression diode 6 to 10 times;
diode assembly 2 to 6 times, varistor +2 to 5 ms).

In addition, fully mounted 3RH22 8-pole contactor relays are


available; the mounted 4-pole auxiliary switch block is not removable. These versions are built according to special Swiss
regulations SUVA and are distinguished externally by a red
labeling plate.
Auxiliary switches according to EN 50005
All contactor relays with the identification numbers 40E, 31E and
22E can be extended with auxiliary switch blocks to obtain contactor relays with 5 to 8 contacts. The permissible combinations
and the resulting identification numbers can be found in the selection tables in Chapter 3, pages 3/48 to 3/52.
Of the auxiliary contacts (integrated plus mountable) possible
on the device, no more than four NC contacts are permitted.

Accessories

Manuals

The accessories for the 3RT2 contactors in size S00 can also be
used for the 3RH2 contactor relays (see pages 5/13 and 5/14
and also Chapter 3).

For more information, see


System manual "SIRIUS Innovations System Overview",
http://support.automation.siemens.com/WW/view/en/60311318
Manual "SIRIUS Innovations SIRIUS 3RT2 Contactors/
Contactor Assemblies",
http://support.automation.siemens.com/WW/view/en/60306557

Article No. scheme


Digit of the article No.

1st - 3rd 4th 5th 6th 7th


@@@

SIRIUS contactor relays

8th 9th 10th 11th 12th

3RH

2nd generation

2
@

Device type (e.g. 1 = 4-pole contactor relay, 2 = 8-pole contactor relay)

Number of NO contacts (e.g. 2 = 2 NO)

Number of NC contacts (e.g. 2 = 2 NC)

Connection type (1 = screw, 2 = spring)

Operating range / solenoid coil circuit (e.g. A = AC standard / without)


Rated control supply voltage (e.g. P0 = 230 V, 50 Hz)

No significance
Special version
Example

13th 14th 15th 16th

3RH

Note:
The article No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
article numbers.

For your orders, please use the article numbers quoted in the
catalog in the Selection and ordering data.

Siemens IC 10 2014

5/5

The 3RH2911.GA .. auxiliary switch blocks are available for terminal designations according to EN 50011 or IEC 60947-5-1
(see page 5/12). They are coded, and therefore cannot be combined with contactor relays with identification numbers 31E
or 22E.

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole

Technical specifications
Contactor relays

Type

3RH2

Size

S00

The contactor relays are designed for operation on a


vertical mounting surface.

360

22,5 22,5

NSB0_00478c

Permissible mounting position

Upright mounting position

NSB0_00477a

Special version required


(3RH2122-2K.40 coupling relays and contactor relays with extended
operating range on request)

3RH22:
Yes, in the basic unit and the auxiliary switch block as well as between
the basic unit and the snap-on auxiliary switch block (permanently
mounted) according to:
ZH 1/457
IEC 60947-5-1, Appendix L

Explanations:
There is positively-driven operation if it is ensured that the NC and
NO contacts cannot be closed at the same time.
ZH1/457
Safety Rules for Controls on Power-Operated Metalworking Presses.
IEC 60947-5-1, Appendix L
Low-voltage switchgear and controlgear, Special requirements for positivelydriven contacts

Note:
3RH2911-.NF. solid-state compatible auxiliary switch blocks have no
positively-driven contacts.

Contact reliability
Contact reliability at 17 V, 1 mA acc. to IEC 60947-5-4

Frequency of contact faults <10-8 i.e. < 1 fault per 100 million operating
cycles

Contact endurance for AC-15/AC-14 and


DC-13 utilization categories
The contact endurance is mainly dependent on the breaking current. It is
assumed that the operating mechanisms are switched randomly, i.e. not
synchronized with the phase angle of the supply system.
If magnetic circuits other than the contactor coil systems or solenoid
valves are present, e.g. magnetic brakes, protective measures for the
load circuits are necessary, e.g. in the form of RC elements and freewheel diodes.
The characteristic curves apply to:

3RH21/3RH22 contactor relays1)


3RH24 latched contactor relays
3RH2911 auxiliary switch blocks1)
Auxiliary switch blocks for snapping onto the front,
max. 4-pole and for mounting onto the side in size S00

30

NSB0_02061b

Basic unit
Million operating cycles (106)

Positively-driven operation of contacts in contactor relays


3RH2:
Yes, in the basic unit and the auxiliary switch block as well as between
the basic unit and the front-mounted auxiliary switch block (removable)
according to:
ZH 1/457
IEC 60947-5-1, Appendix L

10
5
4
3
2
1

DC-13
220 V

Basic unit with


attachable
contact block
DC-13
110 V

AC-15/AC-14
Basic unit with
attachable
contact block

0,5
DC-13
24V

0,1

0,05

0,01
0,01

0,03 0,05 0,1

0,3 0,5

-DC-13 e -DC-13
220 V
110 V
e

Diagram legend:
a = Breaking current
e = Rated operational current
1)

3RH22, 3RH2911: Ie = 6 A for AC-15/AC-14 and DC-13.

5/6

Siemens IC 10 2014

3 4 5 6 7 10
e -DC-13

24 V

(A)

-AC-15
< 230 V
e

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole
3RH21

3RH22

3RH24

Size

S00

S00

S00

mm

45 x 57.5 x 73

--

90 x 57.5 x 73

mm

45 x 57.5 x 116

45 x 57.5 x 116

--

Type

With mounted auxiliary switch block

Dimensions (W x H x D) with screw terminals

General technical specifications


Mechanical endurance
Basic units

Operating cycles 30 million

5 million

Basic unit with snap-on auxiliary switch block

Operating cycles 10 million

5 million

Solid-state compatible auxiliary switch block

Operating cycles 5 million

Rated insulation voltage Ui (pollution degree 3)

690

Rated impulse withstand voltage Uimp

kV

Protective separation between the coil and the contacts in the basic unit
acc. to IEC 60947-1, Appendix N

400

C
C

-25 ... +60


-55 ... +80

Permissible ambient temperature


During operation
During storage
Degree of protection acc. to IEC 60947-1, Appendix C

IP20

Touch protection acc. to EN 50274

Finger-safe

Shock resistance
Rectangular pulse

- AC operation
- DC operation

g/ms
g/ms

7.3/5 and 4.7/10


10/5 and 5/10

Sine pulse

- AC operation
- DC operation

g/ms
g/ms

11.4/5 and 7.3/10


15/5 and 8/10

Short-circuit test with fuse links of operational class gG:


DIAZED, type 5SB; NEOZED, type 5SE
with short-circuit current Ik = 1 kA acc. to IEC 60947-5-1

10

Test with miniature circuit breaker with C characteristic


with short-circuit current Ik = 400 A acc. to IEC 60947-5-1

Short-circuit protection

Conductor cross-sections
Auxiliary conductors and coil terminals
(1 or 2 conductors can be connected)

Screw terminals

Solid or stranded
Finely stranded with end sleeve
AWG cables, solid or stranded

mm2
mm2
AWG

2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1), max. 2 x 4


2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1)
2 x (20 ... 16)1), 2 x (18 ... 14)1)

Terminal screw
- Tightening torque

Nm

M3 (for Pozidriv size 2, 5 ... 6 mm)


0.8 ... 1.2 (7 ... 10.3 lb.in)

Auxiliary conductor and coil terminals2)


(1 or 2 conductors can be connected)

Spring-type terminals

Operating devices3)

mm

3.0 x 0.5; 3.5 x 0.5

mm2
mm2
mm2
AWG

2 x (0.5 ... 4)
2 x (0.5 ... 2.5)
2 x (0.5 ... 2.5)
2 x (20 ... 12)

Operating devices3)

mm

3.0 x 0.5; 3.5 x 0.5

mm2
mm2
mm2
AWG

2 x (0.5 ... 2.5)


2 x (0.5 ... 1.5)
2 x (0.5 ... 2.5)
2 x (20 ... 14)

Solid or stranded
Finely stranded with end sleeve
Finely stranded without end sleeve
AWG cables, solid or stranded

Auxiliary conductors for front and laterally mounted auxiliary switches2)


Solid or stranded
Finely stranded with end sleeve
Finely stranded without end sleeve
AWG cables, solid or stranded

Ring terminal lug connections

Auxiliary conductor and coil terminals


Terminal screw
Tightening torque
Usable ring terminal lugs
- DIN 46234 without insulation sleeve
- DIN 46225 without insulation sleeve
- DIN 46237 with insulation sleeve
- JIS C2805 Type R without insulation sleeve
- JIS C2805 Type RAV with insulation sleeve
- JIS C2805 Type RAP with insulation sleeve

d3
d2

mm

M3, Pozidriv size 2

Nm

5 ... 6

mm

0.8 ... 1.2

mm

d2 = min. 3.2

mm

d3 = max. 7.5

I201_12740

Operating devices

1)

If two different conductor cross-sections are connected to one clamping


point, both cross-sections must lie in one of the ranges specified.
2)
Max. external diameter of the conductor insulation: 3.6 mm.
An insulation stop must be used for spring-type terminals with conductor
cross-sections 1 mm2; see "Accessories", page 5/14.
3)
Tool for opening the spring-type terminals;
see "Accessories", page 5/14.

Siemens IC 10 2014

5/7

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole
Contactor relays

Type

3RH2.

Size

S00

Control circuit
Solenoid coil operating range
AC operation

At 50 Hz
At 60 Hz

0.8 ... 1.1 x Us


0.85 ... 1.1 x Us

DC operation

At 50 C
At +60 C

0.8 ... 1.1 x Us


0.85 ... 1.1 x Us

Power consumption of the solenoid coils


(for cold coil and 1.0 x Us)
AC operation, 50 Hz
- Closing
- Closed

VA/p.f.
VA/p.f.

37/0.8
5.7/0.25

VA/p.f.
VA/p.f.

33/0.75
4.4/0.25

4.0

AC operation, 60 Hz

- Closing
- Closed
DC operation
closing = closed
Permissible residual current of the electronics
(with 0 signal)
For AC operation1)
For DC operation

< 4 mA x (230 V/Us)


< 10 mA x (24 V/Us)

Operating times2)
(Total break time = OFF-delay + Arcing time)
Values apply with coil in cold state and at operating temperature for
operating range
AC operation
Closing
- ON-delay of NO contact

- OFF-delay of NC contact

With 0.8 ... 1.1 x Us


With 1.0 x Us
3RH24 minimum operating time

ms
ms
ms

8 ... 33
9 ... 22
35

With 0.8 ... 1.1 x Us


With 1.0 x Us

ms
ms

6 ... 25
6.5 ... 19

With 0.8 ... 1.1 x Us


With 1.0 x Us
3RH24 minimum operating time

ms
ms
ms

4 ... 15
4.5 ... 15
30

With 0.8 ... 1.1 x Us


With 1.0 x Us

ms
ms

5 ... 15
5 ... 15

With 0.8 ... 1.1 x Us


With 1.0 x Us
3RH24 minimum operating time

ms
ms
ms

30 ... 100
35 ... 50
100

With 0.8 ... 1.1 x Us


With 1.0 x Us

ms
ms

25 ... 90
30 ... 45

With 0.8 ... 1.1 x Us


With 1.0 x Us
3RH24 minimum operating time

ms
ms
ms

7 ... 13
7 ... 12
30

With 0.8 ... 1.1 x Us


With 1.0 x Us

ms
ms

13 ... 19
13 ... 18

ms

10 ... 15

Opening
- OFF-delay of NO contact

- ON-delay of NC contact
DC operation
Closing
- ON-delay of NO contact

- OFF-delay of NC contact
Opening
- OFF-delay of NO contact

- ON-delay of NC contact
Arcing time

Dependence of the switching frequency z'


on the operational current I' and operational voltage U':
z = z Ie/I (Ue/U)1.5 1/h
1)
2)

The 3RT2916-1GA00 additional load module is recommended


for higher residual currents; (see page 5/13).
The OFF-delay of the NO contact and the ON-delay of the NC contact are
increased if the contactor coils are attenuated against voltage peaks
(noise suppression diode 6 to 10 times;
diode assembly 2 to 6 times, varistor +2 to 5 ms).

5/8

Siemens IC 10 2014

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole
Contactor relays

Type

3RH2.

Size

S00

Load side
Load rating with AC
Rated operational currents Ie
AC-12

10

Up to 230 V
400 V
500 V
690 V

A
A
A
A

101)
3
2
1

1 conducting path

24 V
60 V
110 V
220 V
440 V
600 V

A
A
A
A
A
A

10
6
3
1
0.3
0.15

2 conducting paths in series

24 V
60 V
110 V
220 V
440 V
600 V

A
A
A
A
A
A

10
10
4
2
1.3
0.65

3 conducting paths in series

24 V
60 V
110 V
220 V
440 V
600 V

A
A
A
A
A
A

10
10
10
3.6
2.5
1.8

1 conducting path

24 V
60 V
110 V
220 V
440 V
600 V

A
A
A
A
A
A

101)
2
1
0.3
0.14
0.1

2 conducting paths in series

24 V
60 V
110 V
220 V
440 V
600 V

A
A
A
A
A
A

10
3.5
1.3
0.9
0.2
0.1

3 conducting paths in series

24 V
60 V
110 V
220 V
440 V
600 V

A
A
A
A
A
A

10
4.7
3
1.2
0.5
0.26

h-1
h-1
h-1

1 000
1 000
1 000

h-1

10 000

Rated control supply voltage

V AC

max. 600

Rated voltage

V AC

600

AC-15/AC-14 for rated operational voltage Us

Load rating with DC


Rated operational currents Ie

DC-12 for rated operational voltage Us

DC-13 for rated operational voltage Us

Switching frequency
Switching frequency z in operating cycles/hour
For rated operation
For utilization category
No-load switching frequency

AC-12/DC-12
AC-15/AC-14
DC-13

Dependence of the switching frequency z' on


the operational current I' and operational voltage U':
z = z Ie/I (Ue/U)1.5 1/h

s and u rated data


Basic units and auxiliary switch blocks

Switching capacity
Uninterrupted current at 240 V AC
1)

A 600, Q 600
A

10

3RH22, 3RH29: Ie = 6 A for AC-15/AC-14 and DC-13.

Siemens IC 10 2014

5/9

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole

Selection and ordering data


AC operation
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41A
Size S00

3RH2122-1A . .0

3RH2122-2A . .0

Rated operational current Contacts


Ie/AC-15/AC-14
Ident. No. Version
at 230 V

3RH2244-1A . .0

Article No.

NO

NC

3RH2244-2A . .0

DT Screw terminals1)

Rated control
supply voltage Us
at 50/60 Hz2)

DT Spring-type
terminals
Price
per PU

Article No.

Price
per PU

V AC

For screw fixing and snap-on mounting onto


TH 35 standard mounting rail
Terminal designations according to EN 50011
4 NO, Ident. No. 40E
A1(+)
A2()

10

3 NO + 1 NC, Ident. No. 31E

13 23 33 43

A1(+)
A2()

14 24 34 44

2 NO + 2 NC, Ident. No. 22E

13 21 33 43

A1(+)

13 21 31 43

A2()

14 22 34 44

14 22 32 44

40E

--

24
110
230

}
}
}

3RH2140-1AB00
3RH2140-1AF00
3RH2140-1AP00

B
B
}

3RH2140-2AB00
3RH2140-2AF00
3RH2140-2AP00

31E

24
110
230

}
}
}

3RH2131-1AB00
3RH2131-1AF00
3RH2131-1AP00

B
}
}

3RH2131-2AB00
3RH2131-2AF00
3RH2131-2AP00

22E

24
110
230

}
}
}

3RH2122-1AB00
3RH2122-1AF00
3RH2122-1AP00

B
}
}

3RH2122-2AB00
3RH2122-2AF00
3RH2122-2AP00

With permanently mounted auxiliary switch block


4 NO + 4 NC, Ident. No. 44E

6 NO + 2 NC, Ident. No. 62E


A1(+) 13 23 33 43 53 61 71 83

A1(+) 13 23 33 43 51 61 71 81

A2() 14 24 34 44 54 62 72 84

A2() 14 24 34 44 52 62 72 82

44E

230

3RH2244-1AP00

3RH2244-2AP00

62E

230

3RH2262-1AP00

3RH2262-2AP00

1)

The 3RH21/3RH22 contactor relays are also available with ring terminal lug
connection. Please contact your local Siemens representative for information about the special contactor versions with ring terminal lug connection.
2)
Coil operating range
at 50 Hz: 0.8 to 1.1 x Us
at 60 Hz: 0.85 to 1.1 x Us.

5/10

Siemens IC 10 2014

Other voltages according to page 5/12 on request.


Accessories see pages 5/12 to 5/14 and
"Accessories for 3RT2 Contactors", Chapter 3.

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole
DC operation
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41A
Size S00

3RH2122-2B. .0

3RH2244-1B. .0

Rated operational current Contacts


Ie/AC-15/AC-14
Ident. No. Version
at 230 V

Rated control
supply voltage Us

V DC

NO

NC

3RH2244-2B. .0

DT Screw terminals1)
Article No.

DT Spring-type
terminals
Price
per PU

Article No.

Price
per PU

For screw fixing and snap-on mounting onto


TH 35 standard mounting rail
Terminal designations according to EN 50011
4 NO, Ident. No. 40E
A1(+)
A2()

10

3 NO + 1 NC, Ident. No. 31E

13 23 33 43

A1(+)
A2()

14 24 34 44

2 NO + 2 NC, Ident. No. 22E

13 21 33 43

A1(+)
A2()

14 22 34 44

13 21 31 43

14 22 32 44

40E

--

24
220

}
}

3RH2140-1BB40
3RH2140-1BM40

}
B

3RH2140-2BB40
3RH2140-2BM40

31E

24
220

}
A

3RH2131-1BB40
3RH2131-1BM40

}
B

3RH2131-2BB40
3RH2131-2BM40

22E

24
220

}
}

3RH2122-1BB40
3RH2122-1BM40

}
B

3RH2122-2BB40
3RH2122-2BM40

With permanently mounted auxiliary switch block


4 NO + 4 NC, Ident. No. 44E

6 NO + 2 NC, Ident. No. 62E


A1(+) 13 23 33 43 53 61 71 83

A1(+) 13 23 33 43 51 61 71 81

A2() 14 24 34 44 54 62 72 84

A2() 14 24 34 44 52 62 72 82

6
1)

44E

24

3RH2244-1BB40

3RH2244-2BB40

62E

24

3RH2262-1BB40

3RH2262-2BB40

The 3RH21/3RH22 contactor relays are also available with ring terminal lug
connection. Please contact your local Siemens representative for information about the special contactor versions with ring terminal lug connection.

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Other voltages according to page 5/12 on request.


Accessories see pages 5/12 to 5/14 and
"Accessories for 3RT2 Contactors", Chapter 3.

Siemens IC 10 2014

5/11

3RH2122-1B. .0

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole

Options
Rated control supply voltages (change of 10th and 11th digit of the Article No.)
Contactor type
Rated control
supply voltage Us

3RH21, 3RH22

Contactor type
Rated control
supply voltage Us

Control supply voltage at

AC operation

DC operation

Solenoid coils for 50/60 Hz and 60 Hz


50/60 Hz1)

60 Hz

12 V DC
24 V DC
42 V DC

A4
B4
D4

24 V AC
42 V AC
48 V AC

----

B0
D0
H0

48 V DC
60 V DC
110 V DC

W4
E4
F4

110 V AC
220 V AC
230 V AC

----

F0
N2
P0

125 V DC
220 V DC
230 V DC

G4
M4
P4

400 V AC

--

V0

Solenoid coils for USA and Canada2)

3RH21, 3RH22

Control supply voltage at

50 Hz

60 Hz

110 V AC
220 V AC

120 V AC
240 V AC

Solenoid coils for

K6
P6

Japan3)

50/60 Hz

60 Hz

100 V AC
200 V AC
400 V AC

110 V AC
220 V AC
440 V AC

G6
N6
R6

1)

Coil operating range


at 50 Hz: 0.8 to 1.1 x Us
at 60 Hz: 0.85 to 1.1 x Us.
2) Coil operating range
at 50 Hz: 0.85 to 1.1 x Us
at 60 Hz: 0.8 to 1.1 x Us.
3)
Coil operating range
at 50/60 Hz: 0.85 to 1.1 x Us
at 60 Hz: 0.8 to 1.1 x Us.

Accessories
The auxiliary switch blocks according to EN 50011 listed here
should preferably be used for 3RH2 contactor relays.

For auxiliary switch blocks and solid-state compatible auxiliary


switch blocks according to EN 50005 see "Accessories for 3RT2
Contactors", Chapter 3.

PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B

3RH2911-1GA22
For contactor
relays

Contactor relays
with AS block

Auxiliary contacts

Ident. No.

Version
Article No.

Type

NO

3RH2911-2GA22

DT Screw terminals

DT Spring-type
terminals
Price
per PU

Article No.

Price
per PU

NC

Auxiliary switch blocks for snapping onto the front acc. to EN 50011
Blocks for the assembly of contactor relays with 8 contacts1)
3RH2140,
3RH2440,
Ident. No. 40E

80E

--

53 63 73 83

71E

53 61 73 83

62E

53 61 71 83

53E

53 61 71 81

44E

--

51 61 71 81

3RH2911-1GA40

3RH2911-2GA40

3RH2911-1GA31

3RH2911-2GA31

3RH2911-1GA22

3RH2911-2GA22

3RH2911-1GA13

3RH2911-2GA13

3RH2911-1GA04

3RH2911-2GA04

54 64 74 84

54 62 74 84

54 62 72 84

54 62 72 82

52 62 72 82
1)

The 3RH2911-.GA.. auxiliary switches are also available with ring terminal
lug connection. The 8th digit of the Article No. must be changed from a "1"
to a "4", e.g. 3RH2911-1GA22 3RH2911-4GA22.

5/12

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole
More accessory parts see "Accessories for 3RT2 Contactors in
Size S00", Chapter 3.

The following accessory parts are accessories for 3RT2 contactors in size S00, which are also suitable for 3RH2 contactor
relays.
For
Version
contactors

Rated control supply voltage Us1) DT Article No.2)


AC operation

DC operation

Type

V AC

V DC

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

Surge suppressors without LED


(also for spring-type terminals)

3RH2.

Varistor

24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600

24 ... 70
70 ... 150
150 ... 250
---

}
}
}
}
A

3RT2916-1BB00
3RT2916-1BC00
3RT2916-1BD00
3RT2916-1BE00
3RT2916-1BF00

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

41B
41B
41B
41B
41B

3RH2.

RC elements

24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600

24 ... 70
70 ... 150
150 ... 250
---

}
}
}
A
A

3RT2916-1CB00
3RT2916-1CC00
3RT2916-1CD00
3RT2916-1CE00
3RT2916-1CF00

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

41B
41B
41B
41B
41B

3RH2.

Noise suppression diode

--

12 ... 250

3RT2916-1DG00

1 unit

41B

3RH2.

Diode assemblies
(diode and Zener diode) for
DC operation

--

12 ... 250

3RT2916-1EH00

1 unit

41B

PU
(UNIT,
SET,
M)

PS*

PG

3RT2916-1B.00

1)

Can be used for AC operation for 50/60 Hz. Please inquire about further
voltages.

2)

For packs of 10 or 5 units, "-Z" and order code "X90" must be added to the
Article No.
For
Version
contactors

Type

Rated control
supply voltage Us1)
AC
operation

DC
operation

Power
consumption P
of the LED
at Us

V AC

V DC

mW

DT Article No.2)

Price
per PU

Surge suppressors with LED


(also for spring-type terminals)
For plugging onto the front side of the contactors
(with and without auxiliary switch block)
3RH2.

Varistor

24 ... 48
48 ... 127
127 ... 240
--

12 ... 24
24 ... 70
70 ... 150
150 ... 250

10 ... 120
20 ... 470
50 ... 700
160 ... 950

}
}
}
A

3RT2916-1JJ00
3RT2916-1JK00
3RT2916-1JL00
3RT2916-1JP00

1
1
1
1

1 unit
1 unit
1 unit
1 unit

41B
41B
41B
41B

3RH2.

Noise
suppression
diode

----

24 ... 70
50 ... 150
150 ... 250

20 ... 470
50 ... 700
160 ... 950

}
A
}

3RT2916-1LM00
3RT2916-1LN00
3RT2916-1LP00

1
1
1

1 unit
1 unit
1 unit

41B
41B
41B

PU
(UNIT,
SET,
M)

PS*

PG

1 unit

41B

3RT2916-1J.00
1)

Can be used for AC operation for 50/60 Hz. Please inquire about further
voltages.

2)

For packs of 10 or 5 units, "-Z" and order code "X90" must be added to the
Article No.
For
Version
contactors

DT Article No.

Price
per PU

Type

Additional load modules


3RH2.

For plugging onto the front side of the contactors


with or without auxiliary switch blocks1)

3RT2916-1GA00

For increasing the permissible residual current and for limiting


the residual voltage. It ensures the safe opening of contactors
with direct control via 230 V AC semiconductor outputs on
SIMATIC controllers. It acts simultaneously as a surge suppressor.
Rated voltage: AC 50/60 Hz, 180 to 255 V.
Operating range: 0.8 to 1.1 x Us
3RT2916-1GA00
1)

For packs of 10 units, "-Z" and order code "X90" must be added to the
Article No.

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens IC 10 2014

5/13

For plugging onto the front side of the contactors


(with and without auxiliary switch block)

Siemens AG 2013

Contactor Relays
SIRIUS 3RH2 contactor relays,
4- and 8-pole
For contactors

Rated control supply Time setting


voltage Us
range t

Type

DT Screw terminals

Article No.

PU
(UNIT,
SET,
M)

PS*

PG

Price
per PU

OFF-delay devices
For contactor relays with DC operation
Non-adjustable delay time
3RH2. . .-1BF40

110 AC/DC

S00: > 0.1

3RT2916-2BK01

1 unit

41B

3RT2916-2BL01

1 unit

41B

3RT2916-2BE01

1 unit

41B

PU
(UNIT,
SET,
M)

PS*

PG

S0: > 0.08


3RH2. . .-1BM40

220/230 AC/DC

S00: > 0.5


S0: > 0.3

3RH2. . .-1BB40

24 DC

S00: > 0.2

S0: > 0.1


3RT2916-2B.01

For technical specifications, see "Accessories for 3RT20


Contactors", Chapter 3.
For contactors

Version

DT Article No.

Price
per PU

3RH2.

For manual operation of the contactor


contacts for start-up and service

3RT2916-4MC00

5 units

41B

3RH2. 1)

Sealable covers
for preventing manual operation

3RT2916-4MA10

5 units

41B

Type

Control kit

3RT2916-4MC00

Sealable covers

Not suitable for coupling relays

3RT2916-4MA10
1)

Exception: contactors and contactor relays auxiliary switch block mounted


onto the front.
Version

DT Spring-type terminals

Article No.

PU
(UNIT,
SET,
M)

PS*

PG

Price
per PU

Insulation stop for securely holding back the conductor insulation


on conductors up to 1 mm2
Insulation stop strip can be inserted in cable entry of the
spring-type terminal
(2 strips per contactor required)
3RT2916-4JA02

For basic units S00 (3RT201. or 3RH2.),


removable individually

3RT2916-4JA02

1 20 units

41B

3RA2908-1A

41B

Tools for opening spring-type terminals


Screwdrivers
for all SIRIUS devices with spring-type terminals
Length: approx. 200 mm,
3.0 mm x 0.5 mm,
titanium gray/black, partially insulated

1 unit

3RA2908-1A

5/14

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Contactor Relays
SIRIUS 3RH24 latched contactor relays,
4-pole

Overview
Standards

Control circuit

IEC 60947-1, EN 60947-1,


IEC 60947-5-1, EN 60947-5-1

The contactor coil and the coil of the release solenoid are both
designed for uninterrupted duty.

The terminal designations comply with EN 50011.

RC elements, varistors, diodes or diode assemblies can be fitted


to both coils from the front for damping opening surges in the
coil.

Auxiliary switches
The number of auxiliary contacts can be extended by means of
auxiliary switch blocks on the front (up to four contacts).

The contactor relay can also be switched on and released manually. Minimum actuating times, see "Technical Specifications",
page 5/8.

Selection and ordering data

3RH2422-1A. . 0
Rated operational
current
Ie/AC-15/AC-14
at 230 V

Contacts

Rated control supply


voltage Us

Ident. No. acc. to Version


EN 50011

DT Screw terminals

Article No.

NO

NC

PU
(UNIT,
SET,
M)

PS*

PG

Price
per PU

For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Terminal designations according to EN 50011
4 NO, Ident. No. 40E

3 NO + 1 NC, Ident. No. 31E

2 NO + 2 NC, Ident. No. 22E

E1(+) A1+
( ) 13 23 33 43

E1(+) A1(+) 13 21 33 43

E1(+) A1(+) 13 21 31 43

E2(-) A2(-) 14 24 34 44

E2() A2() 14 22 34 44

E2() A2() 14 22 32 44

AC operation
AC 50/60 Hz1)
10

40 E

--

24
110
230

B
B
B

3RH2440-1AB00
3RH2440-1AF00
3RH2440-1AP00

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

31 E

24
110
230

B
B
B

3RH2431-1AB00
3RH2431-1AF00
3RH2431-1AP00

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

22 E

24
110
230

B
B
B

3RH2422-1AB00
3RH2422-1AF00
3RH2422-1AP00

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

40 E

--

24
110
220

B
B
B

3RH2440-1BB40
3RH2440-1BF40
3RH2440-1BM40

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

31 E

24
110
220

B
B
B

3RH2431-1BB40
3RH2431-1BF40
3RH2431-1BM40

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

22 E

24
110
220

B
B
B

3RH2422-1BB40
3RH2422-1BF40
3RH2422-1BM40

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

DC operation
DC
10

1)

Coil operating range


at 50 Hz: 0.8 to 1.1 x Us
at 60 Hz: 0.85 to 1.1 Us.

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Accessories see pages 5/12 and 5/13.

Siemens IC 10 2014

5/15

Siemens AG 2013

Contactor Relays
3TH4 contactor relays,
8- and 10-pole

Overview
Standards

Surge suppression

IEC 60947-1, EN 60947-1,


IEC 60947-5-1, EN 60947-5-1
The 3TH42 and 3TH43 contactor relays are suitable for use in
any climate. They are finger-safe according to EN 50274.

The 3TH42 and 3TH43 contactor relays can be equipped with


RC elements, varistors, diodes or diode assemblies (combination of a diode and a Zener diode) for damping opening surges.
The surge suppressors can be mounted directly on the coil
(see "Accessories", page 5/22).

Terminal designations according to EN 50011

Note:

In terms of their terminal designations, identification numbers


and identification letters, the 3TH42 and 3TH43 contactor relays
conform to the standard EN 50011 for Specific Contactor Relays.

The OFF-delay of the NO contact and the ON-delay of the NC


contact are increased if the contactor coils are attenuated
against voltage peaks (noise suppression diode 6 to 10 times;
diode assembly 2 to 6 times, varistor +2 to 5 ms).

Contact reliability

Technical specifications
Contactor relays

Type

3TH42, 3TH43

Contact endurance for AC-15/AC-14 and


DC-13 utilization categories
The contact endurance is mainly dependent on the breaking current.
It is assumed that the operating mechanisms are switched randomly,
i.e. not synchronized with the phase angle of the supply system.
If magnetic circuits other than the contactor coil systems or solenoid valves
are present, e.g. magnetic brakes, protective measures for the load circuits
are necessary.
RC elements or freewheel diodes are suitable as protective measures for the
circuits.

30
Million operating cycles (106 )

High contact stability at low voltages and currents thanks to the


use of moving double-break contacts, suitable for solid-state
circuits with currents 1 mA at a voltage of 17 V.

NSB0_01391a

10

AC-15/AC-14

DC-13

5
4
3

110 V

DC-13
24 V

DC-13
220 V

1
0,5

0,1
0,01

0,03 0,05

0,1

0,3

e DC-13
220 V

0,5

e DC-13
110 V

3 4 5 7 10
e DC-13
24 V
e

AC-15/AC-14

230 V
Diagram legend:
Prated = Rated power for squirrel-cage motors at 400 V
a = Breaking current
e = Rated operational current

5/16

Siemens IC 10 2014

(A)

Siemens AG 2013

Contactor Relays
3TH4 contactor relays,
8- and 10-pole
Type

3TH42

3TH43

mm

45 x 78 x 97

55 x 78 x 97

mm

45 x 78 x 130

55 x 78 x 130

Dimensions (W x H x D)
DC operation

AC operation

General technical specifications


Permissible mounting position

360

22,5 22,5

DC operation

22,5 22,5
90

90

NSB0_00649a

AC operation

NSB0_00478c

The contactor relays are designed for operation on a


vertical mounting surface.

Upright mounting position


AC and DC operation
NSB0_00477a

Mechanical endurance

Basic units

Special version required


Operating 30 million
cycles
V

690

Rated impulse withstand voltage Uimp

kV

Protective separation between the coil and the main contacts


acc. to IEC 60947-1, Appendix N

Up to 500

During operation

-25 ... +55

During storage

-55 ... +80

Rated insulation voltage Ui


(pollution degree 3)

Permissible ambient temperature

Degree of protection acc. to IEC 60947-1, Appendix C

IP20

Shock resistance
Rectangular pulse
- AC operation
- DC operation

g/ms
g/ms

7.7/5 and 4.4/10


9.3/5 and 5.4/10

g/ms
g/ms

12/5 and 6.8/10


14.7/5 and 8.5/10

A
A
A

16
16
20

A
A

16
16

Sine pulse
- AC operation
- DC operation

Short-circuit protection
Short-circuit test
with fuse links of operational class gG
with short-circuit current Ik = 1 kA acc. to IEC 60947-5-1
- LV HRC, type 3NA
- DIAZED, type 5SB
- NEOZED Type 5SE, quick
with miniature circuit breaker
with short-circuit current Ik = 400 A acc. to IEC 60947-5-1
- C Characteristic
- B Characteristic

s and u rated data


Basic units
Rated control supply voltage Us

Max. 600 V AC, 230 V DC (acc. to UL 240 V DC)

Rated voltage

600 V AC, 600 V DC

Switching capacity

A 600, P 600

Conductor cross-sections
Screw terminals
Solid or stranded
Finely stranded with end sleeve
Terminal screw
1)

mm2
2
mm

2 x (0.5 ... 1)1); 2 x (1 ... 2.5)1); 1 x 4


2 x (0.75 ... 2.5)
M3.5

If two different conductor cross-sections are connected to one clamping


point, both cross-sections must lie in one of the ranges specified.

Siemens IC 10 2014

5/17

Siemens AG 2013

Contactor Relays
3TH4 contactor relays,
8- and 10-pole
Contactor relays

Type

3TH42, 3TH43

Control circuit
Solenoid coil operating range
AC operation

0.8 ... 1.1 x Us1)

DC operation (except 24 V)
At 24 V DC

0.8 ... 1.1 x Us


0.8 ... 1.2 x Us

Power consumption of the solenoid coils (for cold coil and 1.0 x Us)
AC operation, 50 Hz, standard version
- Closing
- Closed

VA/p.f.
VA/p.f.

68/0.82
10/0.29

AC operation, 50/60 Hz, standard version


- Closing, 50 Hz
- Closed, 50 Hz
- Closing, 60 Hz
- Closed, 60 Hz

VA/p.f.
VA/p.f.
VA/p.f.
VA/p.f.

77/0.81
11/0.28
71/0.75
9/0.27

AC operation, 50 Hz, USA/Canada


- Closing
- Closed

VA/p.f.
VA/p.f.

68/0.82
10/0.29

AC operation, 60 Hz, USA/Canada


- Closing
- Closed

VA/p.f.
VA/p.f.

75/0.76
9,4/0.29 ... 0.3

AC operation, 50 Hz, standard version


- Closing
- Closed

VA/p.f.
VA/p.f.

80/0.8
10,7/0.29

AC operation, 60 Hz, standard version


- Closing
- Closed

VA/p.f.
VA/p.f.

75 ... 90/0.73
8,5 ... 10,7/0.29 ... 0.3

6.2

DC operation up to 250 V
Closing = Closed
Permissible residual current of the electronics (with 0 signal)

8 mA x (220 V/Us)
1.25 mA x (220 V/Us)

For AC operation
For DC operation
Operating times2)
Total break time = OFF-delay + arcing time
(the values apply up to and including 20 % undervoltage, 10 % overvoltage, and with the coil in the cold state and at operating temperature)
AC operation
Closing
- ON-delay NO
- OFF-delay NC

ms
ms

8 ... 35
6 ... 20

Opening
- OFF-delay NO
- ON-delay NC

ms
ms

4 ... 18
5 ... 30

Arcing time

ms

10

Closing
- ON-delay NO
- OFF-delay NC

ms
ms

20 ... 170
18 ... 110

Opening
- OFF-delay NO
- ON-delay NC

ms
ms

10 ... 25
15 ... 30

Arcing time

ms

10

Closing
- ON-delay NO
- OFF-delay NC

ms
ms

10 ... 25
7 ... 20

Opening
- OFF-delay NO
- ON-delay NC

ms
ms

5 ... 18
7 ... 20

Closing
- ON-delay NO
- OFF-delay NC

ms
ms

30 ... 70
28 ... 65

Opening
- OFF-delay NO
- ON-delay NC

ms
ms

10 ... 20
15 ... 25

DC operation

Operating times2) at 1.0 x Us


AC operation

DC operation

1)

Coils for USA, Canada and Japan: 0.85 ... 1.1 Us at 60 Hz.

2)

The OFF-delay of the NO contact and the ON-delay of the NC contact are
increased if the contactor coils are attenuated against voltage peaks
(noise suppression diode 6 to 9 times;
diode assembly 2 to 6 times, varistor +2 to 5 ms).

5/18

Siemens IC 10 2014

Siemens AG 2013

Contactor Relays
3TH4 contactor relays,
8- and 10-pole
Contactor relays

Type

3TH42, 3TH43

Load side
Load rating with AC
Rated operational currents Ie
AC-12

16

A
A
A
A

10
6
4
2

230/220 V
400/380 V
500 V
690/660 V

kW
kW
kW
kW

2.4
4
4
4

Up to 48 V
110 V
220 V
440 V

A
A
A
A

10
2.1
0.8
0.6

Up to 48 V
110 V
220 V
440 V

A
A
A
A

10
10
1.6
0.8

Up to 48 V
110 V
220 V
440 V

A
A
A
A

10
10
10
1.3

Up to 24 V
48 V
110 V
220 V
440 V
600 V

A
A
A
A
A
A

10
5
1
0.45
0.25
0.2

Up to 24 V
48 V
110 V
220 V
440 V
600 V

A
A
A
A
A
A

10
10
2.5
0.75
0.5
0.4

Up to 24 V
48 V
110 V
220 V
440 V
600 V

A
A
A
A
A
A

10
10
10
2
0.9
0.8

AC-12/DC-12
AC-2
AC-3
AC-15/AC-14
DC-13

h-1
h-1
h-1
h-1
h-1

1 000
500
1 000
3 600
3 600

No-load switching
frequency

h-1

10 000

AC-15/AC-14 for rated operational voltage Ue


230 V
400 V
500 V
690 V
Rated power of three-phase motors
Acc. to utilization categories AC-2 and AC-3, 50 Hz

Load rating with DC

Rated operational currents Ie


DC-12, for rated operational voltage Ue
1 conducting path

2 conducting paths in series

3 conducting paths in series

DC-13, for rated operational voltage Ue


1 conducting path

2 conducting paths in series

3 conducting paths in series

Switching frequency
Switching frequency z1) in operating cycles/hour
For rated operation
For utilization category

1)

Dependence of the switching frequency z' on the operational current I' and
operational voltage U': z' = z Ie/I' (Ue/U')1.5 1/h.

Siemens IC 10 2014

5/19

Siemens AG 2013

Contactor Relays
3TH4 contactor relays,
8- and 10-pole

Selection and ordering data


8-pole contactor relays

3TH4244-0B. .

Contacts

Number

Rated operational current


Ie/AC-15/AC-14
at
230/
220 V

400/
380 V

500 V

690/
660 V

Contacts

DT Screw terminals

Ident. No. acc. to Version


EN 50011

NO

Article No.

NC

NO

PU
(UNIT,
SET,
M)

PS*

PG

Price
per PU

NC

For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Terminal designations according to EN 50011
8 NO, Ident. No. 80E

7 NO + 1 NC, Ident. No. 71E

A1(+) 13 23 33 43 53 63 73 83
A2( )

A1(+)
A2( )

14 24 34 44 54 64 74 84

5 NO + 3 NC, Ident. No. 53E


A1(+)

6 NO + 2 NC, Ident. No. 62E

13 23 33 43 53 61 73 83

A1(+)
A2( )

14 24 34 44 54 62 74 84

4 NO + 4 NC, Ident. No. 44E

13 23 33 43 53 61 71 81

A1(+)
A2( )

14 24 34 44 54 62 72 82

13 23 33 43 51 61 71 81

14 24 34 44 52 62 72 82

AC operation, rated control supply voltage Us = 50 Hz 230/220 V


8

10

14 24 34 44 54 62 72 84

3 NO + 3 NC and 1 NO + 1 NC make-before-break,
Ident. No. 44E, U
A1(+)

A2( )

13 23 33 43 53 61 71 83

A2( )

13 23 33 47 51 61 71 85

14 24 34 48 52 62 72 86

AC1)

80 E
71 E
62 E
53 E

8
7
6
5

-1
2
3

-----

-----

}
}
}
}

3TH4280-0AP0
3TH4271-0AP0
3TH4262-0AP0
3TH4253-0AP0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

41A
41A
41A
41A

44 E
44 E, U

4
3

4
3

-1

-1

}
}

3TH4244-0AP0
3TH4293-0AP0

1
1

1 unit
1 unit

41A
41A

DC operation, rated control supply voltage Us = 24 V DC


8

1)

10

80 E
71 E
62 E
53 E

8
7
6
5

-1
2
3

-----

-----

}
}
}
}

3TH4280-0BB4
3TH4271-0BB4
3TH4262-0BB4
3TH4253-0BB4

1
1
1
1

1 unit
1 unit
1 unit
1 unit

41A
41A
41A
41A

44 E
44 E, U

4
3

4
3

-1

-1

}
}

3TH4244-0BB4
3TH4293-0BB4

1
1

1 unit
1 unit

41A
41A

Operating range at 220 V: 0.85 to 1.1 x Us;


lower operating range limit according to IEC 60947.

Note:
The solenoid coils of the 3TH42 contactor relays are available in
various voltages as spare parts (on request).
- AC operation: 3TY7403-0A..
- DC operation: 3TY4803-0B..
The contacts cannot be replaced on 3TH42 contactor relays.

5/20

Siemens IC 10 2014

Other voltages according to page 5/22 on request.


Accessories see pages 5/22 and 5/23.

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Contactor Relays
3TH4 contactor relays,
8- and 10-pole
10-pole contactor relays

3TH4355-0A. .
Rated operational current
Ie/AC-15/AC-14
at

Contacts

230 V

400 V

500 V

690 V

3TH4355-0B. .

DT Screw terminals

Ident. No. acc. to Version


EN 50011

Article No.

PU
(UNIT,
SET,
M)

PS*

PG

Price
per PU

Contacts

Number

NO

NC

NO

NC

For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Terminal designations according to EN 50011
10 NO, Ident. No. 100E
A1(+)
A2( )

A1(+)

A2( )

14 24 34 44 54 64 74 84 94 04

7 NO + 3 NC, Ident. No. 73E


A1(+)

A2( )

8 NO + 2 NC, Ident. No. 82E

9 NO + 1 NC, Ident. No. 91E

13 23 33 43 53 63 73 83 93 03

13 23 33 43 53 63 71 83 93 03

A1(+)

A2( )

14 24 34 44 54 64 72 84 94 04

6 NO + 4 NC, Ident. No. 64E

13 23 33 43 53 63 71 81 91 03

A1(+)
A2( )

14 24 34 44 54 64 72 82 92 04

A2( )

13 23 33 43 53 63 71 81 91 01

A1(+)
A2( )

14 24 34 44 54 64 72 82 92 02

13 23 37 43 53 63 71 85 91 03

A1(+)
A2( )

14 24 38 44 54 64 72 86 92 04

10

13 23 33 43 53 61 71 81 91 01

14 24 34 44 54 62 72 82 92 02

4 NO + 4 NC and 1 NO + 1 NC make-before-break,
Ident. No. 44E, 11U

AC operation, rated control supply voltage Us = 50 Hz 230/220 V AC


10

14 24 34 44 54 64 72 84 92 04

5 NO + 5 NC, Ident. No. 55E

6 NO + 2 NC and 1 NO + 1 NC
make-before-break, Ident. No. 63E, 11U
A1(+)

13 23 33 43 53 63 71 83 91 03

13 23 37 43 53 61 71 85 91 01

14 24 38 44 54 62 72 86 92 02

1)

100 E
91 E
82 E
73 E
73 E, U

10
9
8
7
6

-1
2
3
2

----1

----1

}
}
}
}
}

3TH4310-0AP0
3TH4391-0AP0
3TH4382-0AP0
3TH4373-0AP0
3TH4346-0AP0

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

41A
41A
41A
41A
41A

64 E
55 E
55 E, U

6
5
4

4
5
4

--1

--1

}
}
}

3TH4364-0AP0
3TH4355-0AP0
3TH4394-0AP0

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

DC operation, rated control supply voltage Us = 24 V DC1)


10

1)

10

100 E
91 E
82 E
73 E
73 E, U

10
9
8
7
6

-1
2
3
2

----1

----1

}
}
}
}
}

3TH4310-0BB4
3TH4391-0BB4
3TH4382-0BB4
3TH4373-0BB4
3TH4346-0BB4

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

41A
41A
41A
41A
41A

64 E
55 E
55 E, U

6
5
4

4
5
4

--1

--1

}
}
}

3TH4364-0BB4
3TH4355-0BB4
3TH4394-0BB4

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

Operating range at 220 V: 0.85 to 1.1 x Us;


lower operating range limit according to IEC 60947.

Note:
The solenoid coils of the 3TH43 contactor relays are available in
various voltages as spare parts (on request).
- AC operation: 3TY7403-0A..
- DC operation: 3TY4803-0B..
The contacts cannot be replaced on 3TH43 contactor relays.

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Other voltages according to page 5/22 on request.


Accessories see pages 5/22 and 5/23.

Siemens IC 10 2014

5/21

Siemens AG 2013

Contactor Relays
3TH4 contactor relays,
8- and 10-pole

Options
Rated control supply voltages
(change of 10th and 11th digit of the Article No.)
Contactor type
Rated control
supply voltage Us

3TH42/3TH43

Contactor type

Solenoid coils for AC 50 and 60 Hz

AC operation

50/60 Hz

Solenoid coils for AC 50 Hz

50 Hz

60 Hz

24 V AC
36 V AC
42 V AC

29 V AC
42 V AC
50 V AC

B0
G0
D0

48 V AC
60 V AC
110 V AC

58 V AC
72 V AC
132 V AC

H0
E0
F0

125/127 V AC
230/220 V AC
240 V AC

150/152 V AC
276 V AC
288 V AC

L0
P01)
U0

400/380 V AC
415 V AC
500 V AC

480/460 V AC
500 V AC
600 V AC

V01)
R0
S0

100-110 V AC
200-220 V AC

G62)
N62)

120 V AC
240 V AC

K62)
P62)

For USA and Canada


110 V AC
220 V AC
1)

Operating range at 220 V or 380 V: 0.85 to 1.1 x Us.

2)

Operating range at 60 Hz: 0.85 to 1.1 x Us.

24 V AC
42 V AC
110 V AC

C2
D2
G2

115 V AC
120 V AC
220 V AC

J2
K2
N2

230 V AC
240 V AC
440 V AC

L2
P2
R2

DC operation

For Japan
100 V AC
200 V AC

3TH42/3TH43

Rated control
supply voltage Us

Control supply voltage at

12 V DC
24 V DC
30 V DC

A4
B4
C4

36 V DC
42 V DC
48 V DC

V4
D4
W4

60 V DC
110 V DC
125 V DC

E4
F4
G4

220 V DC
230 V DC
240 V DC

M4
P4
Q4

Accessories
Version

Rated control supply


voltage Us

DT Article No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

AC

DC

Noise suppression diodes


with line spacer,
for mounting onto the coil terminal

--

24 ... 250

3TX7402-3A

1 unit

41B

Diode assemblies
(diode and Zener diode) with line spacer,
DC operation,
for mounting onto the coil terminal

--

24 ... 250

3TX7402-3D

1 unit

41B

Varistors2)
with line spacer,
for mounting onto the coil terminal

24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600

24 ... 70
70 ... 150
150 ... 250
---

A
A
A
C
C

3TX7402-3G
3TX7402-3H
3TX7402-3J
3TX7402-3K
3TX7402-3L

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

41B
41B
41B
41B
41B

RC elements
with line spacer,
for mounting onto the coil terminal

24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600

24 ... 70
70 ... 150
150 ... 250
---

A
A
A
B
C

3TX7402-3R
3TX7402-3S
3TX7402-3T
3TX7402-3U
3TX7402-3V

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

41B
41B
41B
41B
41B

Covers
for switch position indicator

--

--

3TX4210-0P

1 unit

41B

Surge suppressors1) for 3TH4 contactor relays

3TX7402-3.

1)

The OFF-delay of the NO contact and the ON-delay of the NC contact are
increased if the contactor coils are attenuated against voltage peaks
(noise suppression diode 6 to 10 times;
diode assembly 2 to 6 times, varistor +2 to 5 ms).
2)
Includes the peak value of the alternating voltage on the DC side.

5/22

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Contactor Relays
3TH4 contactor relays,
8- and 10-pole
For
contactors

Version

Rated control supply Time setting


voltage Us
range
AC 50/60 Hz
(minimum
times)

DT Screw terminals

Article No.
Type

220 ... 230

0.1

PU
(UNIT,
SET,
M)

PS*

PG

Price
per PU

ON-delay devices
3TH42,
3TH43

3TX4180-0A

1 unit

41B

For mounting directly onto contactor coil


without surge suppressor

3TX4090-0C

1 unit

41B

For mounting directly onto contactor coil


with surge suppressor

3TX4090-0D

1 unit

41B

PU
(UNIT,
SET,
M)

PS*

PG

NTC
thermistors
Time tolerance
+100 %, -50 %

3TX4180-0A

Coupling links for control by PLC for 3TH4 contactor relays


Operating range: 17 to 30 V DC
Power consumption: 0.5 W at 24 V DC

3TX4090
mounted to contactor

For contactors

Type

Rated control
supply voltage Us

50/60 Hz AC

DC

OFF-delay
(minimum times)

DT Screw terminals

Article No.
s

Price
per PU

OFF-delay devices for contactors with DC operation


Bridging of voltage interruptions up to 1.2 sec

3TX4701-0AN1

3TH42..-0BF4
3TH43. .-0BF4

110

--

0.15 or 0.3

3TX4701-0AN1

1 unit

41B

3TH42..-0BM4
3TH43..-0BM4

220

--

0.6 or 1.2

3TX4701-0AN1

1 unit

41B

3TH42..-0BP4
3TH43..-0BP4

230

--

0.6 or 1.2

3TX4701-0AN1

1 unit

41B

3TH42..-0BB4
3TH43..-0BB4

--

24

0.4 or 0.8

3TX4701-0BB4

1 unit

41B

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens IC 10 2014

5/23

3TH42,
3TH43

Siemens AG 2013

Contactor Relays
3TH2 contactor relays,
4- and 8-pole

Overview

Accessories

Standards

Auxiliary switch blocks

IEC 60947-1, EN 60947-1,


IEC 60947-5-1, EN 60947-5-1

The contactor relays with 4 contacts with screw terminals can be


expanded by up to 4 contacts by adding snap-on auxiliary
switch blocks (see "Accessories", page 5/30).

The 3TH2 contactor relays are suitable for use in any climate.
Contactor relays with screw terminal are finger-safe according to
EN 50274.
The terminal designations are according to EN 50011.
Connections

The 3TH20 contactor relays with 4 auxiliary contacts are available with SIGUT screw terminals, 6.3 mm x 0.8 mm flat connectors, and solder pin connections.
The contactor relays with 6.3 mm x 0.8 mm flat connectors can
be used in the plug-in base with solder pin connections for
printed circuit boards. The contactor relays are coded, and the
plug-in base is codable in order to ensure non-interchangeability.
The 3TH22 contactor relays with 8 integrated contacts are available with screw terminals. The terminal designations are according to EN 50011.
Contact reliability
High contact stability at low voltages and currents, particularly
suitable for solid-state circuits with currents 1 mA at a voltage
of 17 V.
3TH27 latched contactor relays
The contactor coil and the coil of the release solenoid are both
designed for uninterrupted duty.
RC elements, varistors, diodes or diode assemblies can be fitted
to both coils from the front for damping opening surges in the
coil.
The contactor relay can also be switched on and released
manually.

A cover (with unit labeling plate) must be removed from the front
of the contactor relay for this purpose. The auxiliary switch block
is then easy to mount. The auxiliary switch blocks can be removed again by unlocking them with a laterally arranged orange
slide.
The contactor relays with screw terminals with 4 contacts according to EN 50011 with the identification number 40E can be
expanded with 80E, 71E, 62E, 53E or 44E auxiliary switch blocks
to a total of 8 contacts according to EN 50011. The identification
numbers 80E, 71E, 62E, 53E or 44E on the coded auxiliary
switch blocks apply to the complete contactors. These auxiliary
switch blocks cannot be combined with contactor relays with
identification number 31E and 33E.
All contactor relays with screw terminals with 4 contacts according to EN 50011, identification number 40E, 31E or 22E, can be
expanded with auxiliary switch blocks with identification number
40, 31, 22, 20, 11 or 02 to a total of 6 or 8 contacts according to
EN 50005. The identification numbers on the auxiliary switch
blocks apply only to the attached auxiliary switch blocks.
Surge suppression
RC elements, varistors, diodes or diode assemblies (combination of a diode and a Zener diode for short break times) can be
plugged onto all contactors and auxiliary switch blocks with
screw terminals from the front in order to dampen opening
surges in the coil (see "Accessories", page 5/31).
The unit labeling plate must be removed for this purpose. It can
be snapped onto the attached surge suppressor.
Additional load module
The 3TX4490-1J additional load module (see "Accessories",
page 5/31) can be used by programmable logic controllers to increase permissible residual current, and to limit residual voltage
in semiconductor outputs.
This module ensures the safe shut-down of 3TH2 contactor relays and 3TF2 contactors with direct control via 230 V AC semiconductor outputs. It is accommodated in the same enclosure
as the 3TX4490-3. surge suppressors and can be plugged into
the contactor.

5/24

Siemens IC 10 2014

Siemens AG 2013

Contactor Relays
3TH2 contactor relays,
4- and 8-pole

Technical specifications
Contactor relays

Type

3TH2

Contact endurance for AC-15/AC-14 and


DC-13 utilization categories
30

NSB0_00659

Million operating cycles (106)

Coupling links
10
5
3
2
1
0,5

Contactor relays
and coupling links
DC-13
220 V

DC-13
110 V
DC-13
24 V

AC-15/AC-14

0,1
0,05

0,01
0,01 0,03 0,05 0,1

0,3 0,5

2 3 4 5 7 10

The contact endurance is mainly dependent on the breaking


current. It is assumed that the operating mechanisms are
switched randomly, i.e. not synchronized with the phase angle
of the supply system.
If magnetic circuits other than the contactor coil systems or
solenoid valves are present, e.g. magnetic brakes, protective
measures for the load circuits are necessary. RC elements or
freewheel diodes are suitable as protective measures for the
circuits.
Legend for the diagram:
Ie = Rated operational current
Ia = Breaking current

(A)

-DC-13 e -DC-13 e-DC-13 e-AC-15/AC-14


110 V
24 V
230 V
220 V
e

Positively-driven operation of contacts in contactor relays


3TH20:
Yes, in the basic unit and the auxiliary switch block as well as between the
basic unit and the snap-on auxiliary switch block (removable) acc. to:
ZH 1/457
IEC 60947-5-1, Appendix L
3TH22:
Yes, in the basic unit and the auxiliary switch block as well as between the
basic unit and the snap-on auxiliary switch block (permanently mounted)
according to:
ZH 1/457
IEC 60947-5-1, Appendix L
SUVA

Explanations:
There is positively-driven operation if it is ensured that the
NC and NO contacts cannot be closed at the same time.
ZH1/457
Safety rules for control units on power-operated presses in the
metal-working industry.
IEC 60947-5-1, Appendix L
Low-Voltage Switchgear and Controlgear, Control Circuit Devices and
Switching Elements.
Special requirements for positively-driven contacts
SUVA
Accident prevention regulations of the "Schweizer Unfallverhtungsanstalt"
(Swiss Institute for Accident Insurance)
Contactor relays

Dimensions (W x H x D)
With 3TX4 490 surge suppressor

Type

Auxiliary switch block

3TH20..-....

3TH22..-....

3TX4...-..

mm

45 x 48 x 63

45 x 48 x 91

45 x 33 x 28

mm

45 x 48 x 88

45 x 48 x 116

--

General technical specifications


Permissible mounting position

AC and DC operation

Mechanical endurance

AC operation
DC operation

Any
Operating 10 million
cycles
30 million

Rated insulation voltage Ui


(pollution degree 3)
Screw terminals
Flat connectors 6.3 mm x 0.8 mm
Solder pin connections

V
V
V

690
500
500

500
---

500
---

Rated impulse withstand voltage Uimp


(pollution degree 3)
Screw terminals
Flat connectors 6.3 mm x 0.8 mm
Solder pin connections

kV
kV
kV

6
6
6

6
---

6
---

Up to 300

C
C

-25 ... +55


-55 ... +80

Protective separation between coil and contacts


(according to IEC 60947-1, Appendix N)
Permissible ambient temperature

1)

During operation
During storage

Degree of protection acc. to IEC 60947-1 Appendix C

IP00/open

Connection range for screw terminals

IP20

Touch protection acc. to EN 50274

Finger-safe for screw terminals

Shock resistance
Rectangular pulse

- AC operation
- DC operation

g/ms
g/ms

7/5 and 4/10


10/5 and 6/10

Sine pulse

- AC operation
- DC operation

g/ms
g/ms

9/5 and 6/10


13/5 and 8/10
2)

Conductor cross-sections
1)

Applies to 50/60 Hz coil:


Operating range at 60 Hz: 0.85 ... 1.1 x Us;
at 50 Hz, 1.1 x Us, side-by-side mounting and 100 % ON-period,
the maximum ambient temperature is +40 C.

2)

Conductor cross-sections, see page 5/26.

Siemens IC 10 2014

5/25

Siemens AG 2013

Contactor Relays
3TH2 contactor relays,
4- and 8-pole
Contactor relays

Type

3TH2

Short-circuit protection
Short-circuit test
with fuse links of operational class gG
with short-circuit current Ik = 1 kA acc. to IEC 60947-5-1
LV HRC, type 3NA; DIAZED, type 5SB; NEOZED, type 5SE

Conductor cross-sections
Main and auxiliary conductors

Screw terminals
mm2
mm2

Solid or stranded
Finely stranded with end sleeve
Terminal screw

2 x (0.5 ... 2.5)


2 x (0.5 ... 1.5)
M3
Flat connectors

Finely stranded
When using a plug-in sleeve

- 6.3 ... 1
- 6,3 ... 2.5

mm2
mm2

0.5 ... 1
1 ... 2.5

Solder pin connections


(only for printed circuit boards)
Solder pin cross-section

(does not apply to plug-in


bases)

mm2

0.8 x 1.2

Control circuit
Solenoid coil operating range1)

0.8 ... 1.1 x Us

Power consumption of the solenoid coils


(for cold coil and 1.0 x Us)
AC operation, 50 Hz

AC operation, 60 Hz

AC operation, 50/60 Hz1)

DC operation

Closing
P.f.
Closed
P.f.
Closing
P.f.
Closed
P.f.
Closing
P.f.
Closed
P.f.
Closing = Closed

Permissible residual current of the electronics (with 0 signal)


AC operation
DC operation

VA
VA
VA
VA
VA
VA

15
0.41
6.8
0.42
14.4
0.36
6.1
0.46
16.5/13.2
0.43/0.38
8.0/5.4
0.48/0.42

mA
mA

3 x (220 V/Us)
1 x (220 V/Us)

Operating times for 0.8 ... 1.1 x Us2)


Total break time = Opening delay + Arcing time
Values apply with coil in cold state and at operating temperature for
operating range
AC operation
- Closing

ON-delay NO
OFF-delay NC

ms
ms

5 ... 20
4 ... 12

- Opening

OFF-delay NO
ON-delay NC

ms
ms

3 ... 24
3 ... 20

- Closing

ON-delay NO
OFF-delay NC

ms
ms

16 ... 140
13 ... 40

- Opening

OFF-delay NO
ON-delay NC

ms
ms

3 ... 6
4 ... 10

ms

10

DC operation

Arcing time
Operating times for 1.0 x Us2)
AC operation
- Closing

ON-delay NO
OFF-delay NC

ms
ms

6 ... 17
5 ... 12

- Opening

OFF-delay NO
ON-delay NC

ms
ms

3 ... 24
5 ... 20

- Closing

ON-delay NO
OFF-delay NC

ms
ms

18 ... 42
15 ... 26

- Opening

OFF-delay NO
ON-delay NC

ms
ms

3 ... 5
4 ... 10

DC operation

1)

Applies to 50/60 Hz coil


Operating range at 60 Hz: 0.85 ... 1.1 x Us;
at 50 Hz, 1.1 x Us, side-by-side mounting and 100 % ON-period,
the maximum ambient temperature is +40 C.

5/26

Siemens IC 10 2014

2)

The OFF-delay of the NO contact and the ON-delay of the NC contact are
increased if the contactor coils are attenuated against voltage peaks
(noise suppression diode 6 to 10 times; diode assembly 2 to 6 times,
varistor +2 to 5 ms).

Siemens AG 2013

Contactor Relays
3TH2 contactor relays,
4- and 8-pole
Contactor relays

Type

3TH2

Load side
Load rating with AC
Utilization category AC-12
Rated operational current Ie (at 60 C)

10

230/220 V
400/380 V
500 V
690/660 V

A
A
A
A

4
3
2
1

110 V
230/220 V
400/380 V
500 V
690/660 V

kW
kW
kW
kW
kW

0.2
0.55
1.1
1.5
1.5

10

Utilization categories AC-15 and AC-14

Rated power of three-phase motors


Acc. to utilization category
AC-2 and AC-3

Rated operational current Ie


For rated operational voltage Ue

Load rating with DC


Utilization category DC-12
Rated operational current Ie
For rated operational voltage Ue
1 conducting path1)

Up to 24 V
60 V
110 V
240/220 V

A
A
A
A

4
2
1.1
0.5

2 conducting paths in series

Up to 24 V
60 V
110 V
240/220 V

A
A
A
A

10
10
4
2

3 conducting paths in series

Up to 24 V
60 V
110 V
240/220 V

A
A
A
A

10
10
6
2.5

1 conducting path

Up to 24 V
60 V
110 V
240/220 V

A
A
A
A

2.1
0.9
0.52
0.27

2 conducting paths in series

Up to 24 V
60 V
110 V
240/220 V

A
A
A
A

10
3.5
1.3
0.9

3 conducting paths in series

Up to 24 V
60 V
110 V
240/220 V

A
A
A
A

10
4.7
3
1.2

AC-12/DC-12

h-1

1 000

AC-2
AC-3
AC-15/AC-14
DC-13

h-1
h-1
h-1
h-1
h-1

500
1 000
1 200
1 200
1 0000

Utilization category DC-13


Rated operational current Ie
For rated operational voltage Ue

Switching frequency
Switching frequency z in operating cycles/hour
Rated operation for utilization category
Dependence of the switching frequency z'
on the operational current I' and
operational voltage U'
z = z (Ie/I ) (400 V/U )1.5 1/h

No-load switching frequency


1)

Contact endurance 0.1 x 106 operating cycles.

Siemens IC 10 2014

5/27

Siemens AG 2013

Contactor Relays
3TH2 contactor relays,
4- and 8-pole

Selection and ordering data


Contacts Rated operational current
Ie/AC-15/AC-14
at

Contacts

230/
400/
220 V 380 V

Ident. No.
acc. to
EN 50011

Number

500 V

690/
660 V

DT Screw terminals

Version

NO

Article No.

PU
(UNIT,
SET,
M)

PS*

PG

Price
per PU

NC

For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Terminal designations according to EN 50011

4 NO, Ident. No. 40E

2 NO + 2 NC, Ident. No. 22E

3 NO + 1 NC, Ident. No. 31E

A1(+) 13 23 33 43

A1(+) 13 21 33 43

A1(+) 13 21 31 43

A2( ) 14 24 34 44

A2() 14 22 34 44

A2() 14 22 32 44

AC operation
4

40E
31E
22E

4
3
2

-1
2

A
A
A

3TH2040-0AP0
3TH2031-0AP0
3TH2022-0AP0

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

40E
31E
22E

4
3
2

-1
2

A
A
A

3TH2040-0BB4
3TH2031-0BB4
3TH2022-0BB4

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

DC operation
4

3TH20. .-0A. .

With permanently mounted auxiliary switch blocks


For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Terminal designations according to EN 50011
8 NO, Ident. No. 80E

6 NO + 2 NC, Ident. No. 62E

7 NO + 1 NC, Ident. No. 71E

A1(+) 13 23 33 43 53 63 73 83

A2( ) 14 24 34 44 54 64 74 84

5 NO + 3 NC, Ident. No. 53E

A1(+) 13 23 33 43 53 61 73 83

A1(+) 13 23 33 43 53 61 71 83

A2() 14 24 34 44 54 62 74 84

A2() 14 24 34 44 54 62 72 84

4 NO + 4 NC, Ident. No. 44E

A1(+) 13 23 33 43 53 61 71 81

A1(+) 13 23 33 43 51 61 71 81

A2() 14 24 34 44 54 62 72 82

A2() 14 24 34 44 52 62 72 82

AC operation
8

3TH22. .-0A. .

--

80E
71E
62E

8
7
6

0
1
2

C
C
C

3TH2280-0AP0
3TH2271-0AP0
3TH2262-0AP0

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

53E
44E

5
4

3
4

C
C

3TH2253-0AP0
3TH2244-0AP0

1
1

1 unit
1 unit

41A
41A

80E
71E
62E

8
7
6

0
1
2

C
C
C

3TH2280-0BB4
3TH2271-0BB4
3TH2262-0BB4

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

53E
44E

5
4

3
4

C
C

3TH2253-0BB4
3TH2244-0BB4

1
1

1 unit
1 unit

41A
41A

DC operation
8

--

Latched contactor relays


For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Terminal designations according to EN 50011
4 NO, Ident. No. 40E

2 NO + 2 NC, Ident. No. 22E

3 NO + 1 NC, Ident. No. 31E

E1(+) A1+
( ) 13 23 33 43

E1(+) A1(+) 13 21 33 43

E1(+) A1(+) 13 21 31 43

E2(-) A2(-) 14 24 34 44

E2() A2() 14 22 34 44

E2() A2() 14 22 32 44

AC operation
4

40E
31E
22E

4
3
2

-1
2

C
C
C

3TH2740-0AP0
3TH2731-0AP0
3TH2722-0AP0

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

40E
31E
22E

4
3
2

-1
2

C
C
C

3TH2740-0BB4
3TH2731-0BB4
3TH2722-0BB4

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

DC operation
4

3TH27..

Accessories see pages 5/30 and 5/31.

5/28

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Contactor Relays
3TH2 contactor relays,
4- and 8-pole
Contacts Rated operational current
Ie/AC-15/AC-14 at

Contacts

230/
400/
220 V 380 V

Ident. No.
acc. to
EN 50011

Number

500 V

690/
660 V

DT Flat connectors
Version

NO

Article No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

NC

Contactor relays with 6.3 mm x 0.8 mm flat connectors


Terminal designations according to EN 50011
4 NO, Ident. No. 40E
A1(+)
A2( )

2 NO + 2 NC, Ident. No. 22E

3 NO + 1 NC, Ident. No. 31E

13 23 33 43

A1(+)

A2( )

14 24 34 44

13 21 33 43

A1(+)
A2( )

14 22 34 44

13 21 31 43

14 22 32 44

AC operation

3TH20. .-3. . .

For screw fixing and snap-on mounting onto TH 35 standard mounting


rail
2

--

40E
31E
22E

4
3
2

-1
2

C
D
C

3TH2040-3AP0
3TH2031-3AP0
3TH2022-3AP0

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

--

40E
31E
22E

4
3
2

-1
2

C
C
C

3TH2040-7AP0
3TH2031-7AP0
3TH2022-7AP0

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

For screw fixing (diagonal)


4

DC operation
For screw fixing and snap-on mounting onto TH 35 standard mounting
rail
4

3TH20. .-7. . .

--

40E
31E
22E

4
3
2

-1
2

C
C
D

3TH2040-3BB4
3TH2031-3BB4
3TH2022-3BB4

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

--

40E
31E
22E

4
3
2

-1
2

D
C
C

3TH2040-7BB4
3TH2031-7BB4
3TH2022-7BB4

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

For screw fixing (diagonal)


4

Contactor relays with solder pin connections for printed circuit boards
Terminal designations according to EN 50011
4 NO, Ident. No. 40E
A1(+)
A2( )

Solder pin
connections
3 NO + 1 NC, Ident. No. 31E

13 23 33 43

A1(+)

A2( )

14 24 34 44

2 NO + 2 NC, Ident. No. 22E

13 21 33 43

A1(+)
A2( )

14 22 34 44

13 21 31 43

14 22 32 44

AC operation
For screw fixing (diagonal)
4

--

40E
31E
22E

4
3
2

-1
2

C
C
D

3TH2040-6AP0
3TH2031-6AP0
3TH2022-6AP0

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

--

40E
31E
22E

4
3
2

-1
2

C
C
D

3TH2040-6BB4
3TH2031-6BB4
3TH2022-6BB4

1
1
1

1 unit
1 unit
1 unit

41A
41A
41A

DC operation
3TH20. .-6. . .

For screw fixing (diagonal)


4

Accessories see pages 5/30 and 5/31.

Options
Rated control supply voltages (change of 10th and 11th digit of the Article No.)
Contactor type

3TH20..-0...

Rated control supply voltage Us

3TH20..-3...,
3TH20..-6...,
3TH20..-7...,
3TH22, 3TH27

AC operation

Contactor type

3TH20..-0...

3TH20..-3...,
3TH20..-6...,
3TH20..-7...,
3TH22, 3TH27

B4
F4
M4

B4
---

Rated control supply voltage Us

DC operation

Solenoid coils for AC 50 and 60 Hz


50 Hz

60 Hz

24 V AC
110 V AC
230/220 V AC

29 V AC
132 V AC
276 V AC

B0
F0
P01)

--P01)

24 V DC
110 V DC
220 V DC
1)

Operating range at 220 V or 380 V:


0.85 to 1.15 x Us; lower operating range limit according to IEC 60947.

Please inquire about further voltages.


* You can order this quantity or a multiple thereof.
Illustrations are approximate

Siemens IC 10 2014

5/29

Siemens AG 2013

Contactor Relays
3TH2 contactor relays,
4- and 8-pole

Accessories
Rated operational
current
Ie/AC-15/AC-14 at

Contacts

DT Screw terminals

230/ 400/
500 V Ident. No. Version
220 V 380 V

NO NC

Article No.

PU
(UNIT,
SET,
M)

PS*

PG

Price
per PU

NO NC

Snap-on auxiliary switch blocks for 3TH20 contactor relays


For expansion to 8 contacts according to EN 50011
Only for 3TH2040-0... (with 4 NO, Ident. No. 40E)
4

3TX4440-0A

80E
71E
62E
53E
44E

4
3
2
1
--

-1
2
3
4

------

------

}
}
}
}
}

3TX4440-0A
3TX4431-0A
3TX4422-0A
3TX4413-0A
3TX4404-0A

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

41A
41A
41A
41A
41A

For expansion to 6 or 8 contacts according to EN 50005


4

40E

--

--

--

53 63 73 83

3TX4440-2A

1 unit

41A

31E

--

--

54 64 74 84
53 61 73 83

3TX4431-2A

1 unit

41A

22E

--

--

54 62 74 84
53 61 71 83

3TX4422-2A

1 unit

41A

22; 2U

--

--

54 62 72 84
57 67 75 85

3TX4422-2G

1 unit

41A

20E

--

--

--

53 63

3TX4420-2A

1 unit

41A

11E

--

--

54 64
53 61

3TX4411-2A

1 unit

41A

02E

--

--

--

51 61

3TX4402-2A

1 unit

41A

11; U

--

--

52 62
57 65

3TX4411-2G

1 unit

41A

PU
(UNIT,
SET,
M)

PS*

PG

58 68 76 86

54 62

58 66

For contactors

Type

Rated control supply voltage Us OFF-delay


(minimum times)

50/60 Hz AC

DC

DT Screw terminals

Article No.

Price
per PU

OFF-delay devices for contactors with DC operation


Bridging of voltage interruptions up to 0.8 sec
3TH2. . .-0BB4

--

24

0.25 or 0.5

3TX4490-1H

1 unit

41B

3TH2. . .-0BF4

110

--

0.1 or 0.2

3TX4490-1A

1 unit

41B

3TH2. . .-0BM4,
3TH2. . .-0BP4

220/230

--

0.4 or 0.8

3TX4490-1A

1 unit

41B

3TX4490-1A

5/30

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Contactor Relays
3TH2 contactor relays,
4- and 8-pole
For contactors

Rated control
supply voltage Us

Power consumption
of LED at Us

Type

V AC

mW

V DC

DT Article No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

Surge suppressors1)
for plugging onto contactors with and without auxiliary switch blocks
Version without LED
RC elements
3TH2. . .-0. . .

3TX4490-3A

24 ... 48
48 ... 127
127 ... 240

24 ... 70
70 ... 150
150 ... 250

----

B
B
B

3TX4490-3R
3TX4490-3S
3TX4490-3T

1
1
1

1 unit
1 unit
1 unit

41B
41B
41B

240 ... 400


400 ... 600

---

---

B
B

3TX4490-3U
3TX4490-3V

1
1

1 unit
1 unit

41B
41B

48
48 ... 127
127 ... 240

24 ... 70
70 ... 150
150 ... 250

----

}
B
B

3TX4490-3G
3TX4490-3H
3TX4490-3J

1
1
1

1 unit
1 unit
1 unit

41B
41B
41B

240 ... 400


400 ... 600

---

---

B
B

3TX4490-3K
3TX4490-3L

1 10 units
1 10 units

41B
41B

12 ... 250

--

3TX4490-3A

1 unit

41B

24 ... 250

--

3TX4490-3B

1 unit

41B

12 ... 24
24 ... 70
70 ... 150
150 ... 250

10 ... 120
20 ... 470
50 ... 700
160 ... 950

B
B
B
D

3TX4490-4G
3TX4490-4H
3TX4490-4J
3TX4490-4K

1
1
1
1

1 unit
1 unit
1 unit
1 unit

41B
41B
41B
41B

24 ... 70
70 ... 150
150 ... 250

20 ... 470
50 ... 700
160 ... 950

B
B
B

3TX4490-4A
3TX4490-4B
3TX4490-4C

1
1
1

1 unit
1 unit
1 unit

41B
41B
41B

3TX4490-1J

1 unit

41B

3TX4491-2A

5 units

41A

3TX4491-2K

1 unit

41A

Noise suppression diodes


3TH2. . .-0. . .

--

Diode assemblies (diode and Zener diode)


For DC operation and short break times
3TH2. . .-0. . .

--

Version with LED


Varistors
3TH2. . .-0. . .

24 ... 48
48 ... 127
127 ... 240
--

3TX4490-4G
Noise suppression diodes
3TH2. . .-0. . .

----

Additional load modules for 3TH2 contactor relays


for plugging onto contactors with and without auxiliary switch blocks
For increasing the permissible residual current and for limiting the
residual voltage of SIMATIC semiconductor outputs
3TH2. . .-0A. .
3TX4490-1J

230/220, 50 Hz
-230, 60 Hz
-230, 50/60 Hz
-Operating range 0.8 ... 1.1 Us

Plug-in bases with solder pin connections for printed circuit boards,
width 45 mm
For 3TH2 contactor relays;
with flat connectors 1 x 6.3 mm ... 0.8 mm
Rated insulation voltage Ui: 400 V (at pollution degree 3);
rated impulse withstand voltage Uimp: 6 kV;
rated operational current Ie: 6 A;
s and U rated data: max. 300 V, 6 A
3TX4491-2A

3TH20. .-3. . .,
3TH20. .-7. . .

Release tools
3TH20. .-7. . .
1)

For releasing contactors from


3TX4491-2A plug-in bases

The OFF-delay of the NO contact and the ON-delay of the NC contact are
increased if the contactor coils are attenuated against voltage peaks
(noise suppression diode 6 to 10 times;
diode assembly 2 to 6 times, varistor +2 to 5 ms).

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens IC 10 2014

5/31

Varistors
3TH2. . .-0. . .

Siemens AG 2013

Contactor Relays
Coupling Contactors
SIRIUS 3RH21 coupling contactors
for switching auxiliary circuits, 4-pole

Overview
The 3RH21 coupling contactors cannot be extended with
auxiliary switch blocks.

DC operation
IEC 60947-1, EN 60947-1,
IEC 60947-5-1, EN 60947-5-1
The 3RH21 coupling contactors for switching auxiliary circuits
are tailored to the special requirements of working with electronic controls.

Coupling contactors have a low power consumption and an


extended solenoid coil operating range.
Depending on the version, solenoid coils are supplied either
without overvoltage damping (versions 3RH21 . .-.HB40 or
3RH21 . .-.MB40-0KT0) or with a diode or suppressor diode
connected as standard.

Technical specifications

All technical specifications not mentioned in the table below


are identical to those of the 3RH21 contactor contactors
(see page 5/6).
Contactor type

3RH21. .-.HB40

3RH21. .-.JB40

3RH21. .-.KB40

Size

S00

S00

S00

With diode

With suppressor diode

38 ... 65
55 ... 75

7 ... 20
20 ... 30

Control circuit
0.7 ... 1.25 x Us

Solenoid coil operating range


Power consumption of the solenoid coil
(for cold coil)
Closing = Closed
At Us = 17 V

1.4

At Us = 24 V
At Us = 30 V

2.8

4.4

Permissible residual current


of the electronics for 0 signal

< 10 mA x (24 V/Us)

Overvoltage configuration of the solenoid coil

No overvoltage damping

Operating times
Closing at 17 V
- ON-delay NO
- OFF-delay NC

ms
ms

40 ... 130
30 ... 80

At 24 V
- ON-delay NO
- OFF-delay NC

ms
ms

35 ... 60
25 ... 40

At 30 V
- ON-delay NO
- OFF-delay NC

ms
ms

25 ... 50
15 ... 30

Closing at 17 ... 30 V
- OFF-delay NO
- ON-delay NC

ms
ms

7 ... 20
20 ... 30

Upright mounting position

On request

Contactor type

3RH21. .-.MB40-0KT0

3RH21. .-.VB40

3RH21. .-.WB40

Size

S00

S00

S00

Control circuit
0.85 ... 1.85 x Us

Solenoid coil operating range


Power consumption of the solenoid coil
(for cold coil)
Closing = Closed at Us = 24 V

1.6

Permissible residual current


of the electronics for 0 signal

< 8 mA x (24 V/Us)

Overvoltage configuration of the solenoid coil

Diode, varistor or RC element, Built-in diode


attachable

5/32

Siemens IC 10 2014

Built-in suppressor diode

Siemens AG 2013

Contactor Relays
Coupling Contactors
SIRIUS 3RH21 coupling contactors
for switching auxiliary circuits, 4-pole
Contactor type

3RH21. .-.MB40-0KT0

3RH21. .-.VB40

3RH21. .-.WB40

Size

S00

S00

S00

20 ... 80
30 ... 90

5 ... 20
10 ... 30

Control circuit
Operating times
Closing at 20.5 V
- ON-delay NO
- OFF-delay NC

ms
ms

30 ... 120
20 ... 110

At 24 V
- ON-delay NO
- OFF-delay NC

ms
ms

25 ... 90
15 ... 80

At 44 V
- ON-delay NO
- OFF-delay NC

ms
ms

15 ... 60
10 ... 50

Closing at 17 ... 30 V
- OFF-delay NO
- ON-delay NC

ms
ms

5 ... 20
10 ... 30
On request

Upright mounting position

Selection and ordering data


DC operation
Low power consumption
Extended operating range of the solenoid coil
Integrated coil circuit
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41A

3RH21. .-1.B40
Rated operational current
Ie/AC-15/ AC-14
at 230 V

Auxiliary contacts
Ident. No. acc. to
EN 50011

DT Screw terminals

DT Spring-type terminals

Version
Article No.

NO

3RH21. .-2.B40

Price
per PU

Article No.

Price
per PU

NC

For screw fixing and snap-on mounting onto


TH 35 standard mounting rail
Size S00
Diode, varistor or RC element, attachable
Terminal designations according to EN 50011 (auxiliary switch blocks cannot be mounted)
4 NO, Ident. No. 40E
A1(+)
A2()

3 NO + 1 NC, Ident. No. 31E

13 23 33 43

13 21 33 43

A1(+)
A2()

14 22 34 44

14 24 34 44

2 NO + 2 NC, Ident. No. 22E


A1(+)

13 21 31 43

A2()

14 22 32 44

Rated control supply voltage Us = 24 V DC,


operating range 0.7 to 1.25 x Us
Power consumption of the solenoid coils 2.8 W at 24 V
10

40E
31E
22E

4
3
2

-1
2

B
B
B

3RH2140-1HB40
3RH2131-1HB40
3RH2122-1HB40

B
B
B

3RH2140-2HB40
3RH2131-2HB40
3RH2122-2HB40

-1
2

B
B
B

3RH2140-1MB40-0KT0
3RH2131-1MB40-0KT0
3RH2122-1MB40-0KT0

B
B
B

3RH2140-2MB40-0KT0
3RH2131-2MB40-0KT0
3RH2122-2MB40-0KT0

Rated control supply voltage Us = 24 V DC,


operating range 0.85 to 1.85 x Us
Power consumption of the solenoid coils 1.6 W at 24 V
10

40E
31E
22E

4
3
2

For surge suppressors, see page 5/13.

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens IC 10 2014

5/33

Siemens AG 2013

Contactor Relays
Coupling Contactors
SIRIUS 3RH21 coupling contactors
for switching auxiliary circuits, 4-pole
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41A

3RH21. .-1.B40
Auxiliary contacts
Ident. No. acc. to
EN 50011

3RH21. .-2.B40

DT Screw terminals

DT Spring-type terminals

Version
Article No.

Price
per PU

Article No.

Price
per PU

Rated operational current


Ie/AC-15/ AC-14
at 230 V

NO

NC

For screw fixing and snap-on mounting onto


TH 35 standard mounting rail
Size S00
With integrated coil circuit (diode)
Terminal designations according to EN 50011 (auxiliary switch blocks cannot be mounted)
4 NO, Ident. No. 40E
A1(+)
A2()

3 NO + 1 NC, Ident. No. 31E

13 23 33 43

13 21 33 43

A1(+)
A2()

14 24 34 44

2 NO + 2 NC, Ident. No. 22E


A1(+)

13 21 31 43

A2()

14 22 34 44

14 22 32 44

Rated control supply voltage Us = 24 V DC,


operating range 0.7 to 1.25 x Us
Power consumption of the solenoid coils 2.8 W at 24 V
10

40E
31E
22E

4
3
2

-1
2

B
}
}

3RH2140-1JB40
3RH2131-1JB40
3RH2122-1JB40

B
}
B

3RH2140-2JB40
3RH2131-2JB40
3RH2122-2JB40

-1
2

B
B
B

3RH2140-1VB40
3RH2131-1VB40
3RH2122-1VB40

B
B
B

3RH2140-2VB40
3RH2131-2VB40
3RH2122-2VB40

Rated control supply voltage Us = 24 V DC,


operating range 0.85 to 1.85 x Us
Power consumption of the solenoid coils 1.6 W at 24 V
10

40E
31E
22E

4
3
2

With integrated coil circuit (suppressor diode)


Terminal designations according to EN 50011 (auxiliary switch blocks cannot be mounted)
4 NO, Ident. No. 40E
A1(+)
A2()

3 NO + 1 NC, Ident. No. 31E

13 23 33 43

13 21 33 43

A1(+)
A2()

14 24 34 44

2 NO + 2 NC, Ident. No. 22E


A1(+)
A2()

14 22 34 44

13 21 31 43

14 22 32 44

Rated control supply voltage Us = 24 V DC,


operating range 0.7 to 1.25 x Us
Power consumption of the solenoid coils 2.8 W at 24 V
10

40E
31E
22E

4
3
2

-1
2

B
}
}

3RH2140-1KB40
3RH2131-1KB40
3RH2122-1KB40

B
}
}

3RH2140-2KB40
3RH2131-2KB40
3RH2122-2KB40

-1
2

B
B
B

3RH2140-1SB40
3RH2131-1SB40
3RH2122-1SB40

B
B
B

3RH2140-2SB40
3RH2131-2SB40
3RH2122-2SB40

Rated control supply voltage Us = 24 V DC,


operating range 0.85 to 1.85 x Us
Power consumption of the solenoid coils 1.6 W at 24 V
10

5/34

40E
31E
22E

Siemens IC 10 2014

4
3
2

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Contactor Relays
Contactors with Extended Operating Range 0.7 ... 1.25 x Us for Railway Applications
SIRIUS 3RH21 contactor relays
Note:

Overview

An additional auxiliary switch block cannot be mounted.

DC operation

Side-by-side mounting

IEC 60947-4-1, EN 60947-4-1

A clearance of 10 mm is required for side-by-side mounting at


ambient temperatures > 60 C 70 C.

The contactor relays are finger-safe according to EN 50274. The


size S00 contactor relays have spring-type connections for all
terminals.

Contactor relays with series resistor

Ambient temperature

Control and auxiliary circuits

The permissible ambient temperature for operation of the


contactor relays (across the full solenoid coil operating range) is
-40 to +70 C.

The DC solenoid systems of the contactor relays are modified


(to holding excitation) by means of a series resistor.
The size S00 contactor relays are supplied prewired with a plugon module containing the series resistor. A surge suppressor
(a suppressor diode or varistor as preferred) is integrated.

Uninterrupted duty at temperatures > +60 C reduces the


mechanical endurance, the current carrying capacity of the
conducting paths and the switching frequency.

The solenoid coils of the contactor relays have an extended coil


operating range from 0.7 to 1.25 x Us and are fitted as standard
with surge suppressors. The opening delay is consequently
2 to 5 ms longer than for standard contactors.

L+
L-

Control and auxiliary circuits

S1

E1+

For operation in installations which are subject both to considerable variations in the control voltage and to high ambient temperatures, e.g. railway applications under extreme climatic conditions, rolling mills, etc.

K1

K1
A2-

13 23 31

14 24 32

Also for control supply voltages with battery buffering to extend


the operating time in the event of battery charge failure.

NSB0_02177

Application

RV

Contactor relays with conventional coil

Circuit diagram (version with suppressor diode)

Control and auxiliary circuits

A 4-pole auxiliary switch block (according to EN 50005) can be


fitted additionally.

These contactor relays have an extended operating range from


0.7 to 1.25 x Us; the solenoid coils are fitted as standard with a
suppressor diode. An additional series resistor is not required.

Side-by-side mounting
Side-by-side-side mounting is permissible at ambient temperatures up to 70 C.

Technical specifications
Contactor relays

Type

3RH21..

General technical specifications


Upright mounting position
Contactors with series resistor

Special version (on request)

Contactors with conventional coil

Special version (on request)

Ambient temperature
During operation

-40 ... +701)

During storage

-55 ... +80

Control circuit
Solenoid coil operating range

DC

0.7 ... 1.25 x Us


For cold coil and 1.0 x Us

Power consumption of the solenoid coils


Contactors with series resistor

- Closing
- Closed

W
W

13
4

Contactors with conventional coil

- Closing
- Closed

W
W

2.8
2.8

All details and technical specifications not mentioned here are


identical to those of the standard versions; see page 5/4.
1)

3RH21..-.K contactor relays without the suffix -0LA0 are coupling contactor
relays that are certified for the temperature range -25 C to +60 C.
For railway applications, an additional certification approves these contactors with a minimum distance of 10 mm for the extended temperature
range -40 C to +70 C.

Siemens IC 10 2014

5/35

Siemens AG 2013

Contactor Relays
Contactors with Extended Operating Range 0.7 ... 1.25 x Us for Railway Applications
SIRIUS 3RH21 contactor relays

Selection and ordering data


DC operation
Spring-type terminals
For screw and snap-on mounting onto standard mounting rails
Solenoid coil with surge suppression

3RH2122-2K.40
Rated operational current
Ie/AC-15/AC-14
Tu: 70 C at
230 V

400 V

500 V

Contacts

690 V

Rated control supply


voltage Us

3RH2122-2K.40-0LA0

DT Spring-type terminals

PS*

PG

Version
Article No.

PU
(UNIT,
SET, M)

NO

NC

Price
per PU

V DC

3RH21 contactor relays


Size S00
With conventional coil, fitted with suppressor diode
Terminal designations according to EN 50011
2 NO + 2 NC, Ident. No. 22E
A1(+)
A2()

10

3 NO + 1 NC, Ident. No. 31E

13 21 31 43

A1(+)
A2()

14 22 32 44

1)

24
110

1)

01)

21)

4 NO, Ident. No. 40E

13 21 33 43

A1(+)
A2()

14 22 34 44

13 23 33 43

14 24 34 44

}
A

3RH2122-2KB40
3RH2122-2KF40

1
1

1 unit
1 unit

41A
41A

24

3RH2131-2KB40

1 unit

41A

24

3RH2140-2KB40

1 unit

41A

24
110

B
B

3RH2122-2LB40
3RH2122-2LF40

1
1

1 unit
1 unit

41A
41A

12)

24
110

B
B

3RH2122-2KB40-0LA0
3RH2122-2KF40-0LA0

1
1

1 unit
1 unit

41A
41A

12)

24
110

B
B

3RH2122-2LB40-0LA0
3RH2122-2LF40-0LA0

1
1

1 unit
1 unit

41A
41A

With conventional coil, fitted with varistor


Terminal designations according to EN 50011
2 NO + 2 NC, Ident. No. 22E
A1(+)
A2()

10

13 21 31 43

14 22 32 44

With series resistor, fitted with suppressor diode


Terminal designations according to EN 50011
2 NO + 1 NC, Ident. No. 21X
E1(+)
A2()

10

13 23 31

14 24 32

With series resistor, fitted with varistor


Terminal designations according to EN 50011
2 NO + 1 NC, Ident. No. 21X
E1(+)

A2()

10
1)
2)

13 23 31

14 24 32

It is not possible to mount an auxiliary switch block.


4-pole auxiliary switch block according to EN 50005 can be mounted.

5/36

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Contactor Relays
Contactors with Extended Operating Range 0.7 ... 1.25 x Us for Railway Applications
3TH4 contactor relays

Overview

Application
For operation in plants which are subject both to considerable
variations in the control voltage and to high ambient temperatures, e.g. in railway applications.

Standards
IEC 60947-4-1, EN 60947-4-1
The contactor relays are finger-safe according to EN 50274.
Terminal covers may have to be fitted onto the connecting bars,
depending on the configuration with other devices.

Control and auxiliary circuits


The solenoid coils of the contactor relays have an extended coil
operating range from 0.7 to 1.25 x Us and are fitted as standard
with varistors to provide protection against overvoltage. The
opening delay is consequently 2 to 5 ms longer than for standard contactors.

Ambient temperature
The permissible ambient temperature for operation of the
contactors (across the full solenoid coil operating range) is
-50 to +70 C. Uninterrupted duty at temperatures < -25 C and
> +55 C reduces the mechanical endurance, the currentcarrying capacity of the conducting paths and the switching
frequency.

A clearance of 10 mm is required for side-by-side mounting at


ambient temperatures > 55 C. There is no need to reduce the
technical specifications.

Technical specifications
Contactor relay

Type

3TH42

General technical specifications


Permissible ambient temperature
During operation

-50 ... +701)

During storage

-55 ... +80

Control circuit
0.7 ... 1.25 x Us

Solenoid coil operating range


Power consumption of the solenoid coils (for cold coil)
0.7 x Us W
1.0 x Us W
1.25 x Us W

(For cold coil: Closing = Closed)

2.6
5.2
8.2

Permissible residual current of the electronics (with 0 signal)


10 mA x (24 V/Us)

DC operation
Operating times
(Total break time = OFF-delay + Arcing time)
Closing
- 0,7 x Us

ON-delay (NO)
OFF-delay (NC)

ms
ms

70 ... 200
28 ... 33

- 1 x Us

ON-delay (NO)
OFF-delay (NC)

ms
ms

45 ... 80
30 ... 34

- 1.25 x Us

ON-delay (NO)
OFF-delay (NC)

ms
ms

40 ... 60
31 ... 35

OFF-delay (NO)
ON-delay (NC)

ms
ms

20 ... 30
22 ... 32

ms

10

Opening
- 0.7 ... 1.25 x Us
Arcing time
1)

Side-by-side mounting with 10 mm distance.

All details and technical specifications not mentioned here are


identical to those of the standard versions; see page 5/16.

Siemens IC 10 2014

5/37

Siemens AG 2013

Contactor Relays
Contactors with Extended Operating Range 0.7 ... 1.25 x Us for Railway Applications
3TH4 contactor relays

Selection and ordering data


Solenoid coil fitted with varistor

3TH4244-0L. .

Contacts Rated operational current


Ie/AC-15/AC-14

Number

230 V

400 V

500 V

690 V

Contacts1)

Ident. No.
acc. to
EN 50011

Rated control supply


voltage Us

DT Screw terminals

Version

NO

NC

Article No.

PU
(UNIT,
SET, M)

PS*

PG

Price
per PU

V DC

For screw fixing and snap-on mounting onto TH 35 standard mounting rail
DC operation
A1(+)
A2( )

10

A2( )

10

A2( )

1)

10

62E

24
110

}
}

3TH4244-0LB4
3TH4244-0LF4

1
1

1 unit
1 unit

41A
41A

}
}

3TH4253-0LB4
3TH4253-0LF4

1
1

1 unit
1 unit

41A
41A

}
}

3TH4262-0LB4
3TH4262-0LF4

1
1

1 unit
1 unit

41A
41A

13 23 33 43 53 61 71 81

14 24 34 44 54 62 72 82

53E

A1(+)

14 24 34 44 52 62 72 82

44E

A1(+)

13 23 33 43 51 61 71 81

24
110

13 23 33 43 53 61 71 83

14 24 34 44 54 62 72 84

24
110

Contacts not extendable.

Accessories see page 5/22.

5/38

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Relay couplers

Overview
The semiconductor couplers have a low power consumption
and are therefore particularly well suited for solid-state systems.

In the coupling links in double-decker design, the connections


are arranged on two levels; these units are extremely compact.
Connection method: Screw terminals or spring-type terminals.
For test purposes, versions are available with manual-0-automatic switches.

I/O devices
110 V AC
230 V AC

Electronic control
24 V DC

Pushbutton Coupling
Position
link
switch

The input and output coupling links differ with regard to the positioning of the terminals and the LEDs. For equipment identification purposes, each coupling link has a blank labeling plate.

24 V DC

Output

IEC 60947-5-1, EN 60947-5-1

Input

AC and DC operation

Actuators
110 V AC
230 V AC
M

NSB0_00186

Coupling
link

Motor
contactor

Application example: Motor control

Type

3TX7002, 3TX7003

3TX7004, 3TX7005

mm

W x 60 x 62

B x 80 x 85

Rated insulation voltage Ui (pollution degree 3)

300

Protective separation1) between coil and contacts


acc. to IEC 60947-1, Appendix N

Up to 300 AC

C
C

-25 ... +60


-40 ... +80

Dimensions (W x H x D)

Technical specifications

For width B see "Selection and ordering data"

General technical specifications

Permissible ambient temperature


During operation
During storage
Degree of protection
Connections
Enclosure

IP20
IP30

Short-circuit protection
Short-circuit test with fuse links of operational class gG
with short-circuit current Ik = 1 kA acc. to IEC 60947-5-1

Conductor cross-sections
For 3TX7002, 3TX7004:

Screw terminals
mm2
mm2

Solid
Finely stranded with end sleeve
Terminal screws
- Corresponding opening tool

1 x (0.25 ... 4)
1 x (0.5 ... 2.5)
M3
Screwdriver, size 3.5 mm x 0.5 mm

For 3TX7003, 3TX7005:

Spring-type terminals
mm2
mm2

Solid or finely stranded


Finely stranded with end sleeve
Corresponding opening tool
1)

1 x (0.08 ... 2.5)


1 x (0.25 ... 1.5)
Screwdriver, size 3.0 mm x 0.5 mm (3RA2908-1A)

For 3TX700.-1FB02, no protective separation acc. to IEC 60947-1,


Appendix N.

Type

3TX7002-,
3TX7003-

1AB00 1BB00 1FB02


1AB02

1CB00 2AB00 2AE00

1BF00
2BF02

2AF00
2AF05

Control side
0.8 ... 1.25 x Us

Operating range

0.8 ... 1.1 x Us

Power consumption
At Us = 24 V AC/DC
At Us = 230 V AC/DC

W
W

Type

0.75
--

1.2
--

3TX7004, 3TX7005

0.75
--

-1.2

Exception: 3TX7005-...05

Control side
Operating range
At Us = 24 V AC/DC
At Us = 110 V AC/DC and 230 V
- Exception: 3TX7005-1LN00

0.7 ... 1.25 x Us


0.8 ... 1.1 x Us
0.7 ... 1.25 x Us

Power consumption
At Us = 24 V AC/DC
At Us = 230 V AC
At Us = 230 V DC

VA/W
VA
W

0.5

-6
1

Siemens IC 10 2014

5/39

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Relay couplers
Type

3TX7002,
3TX7003

Exception: 3TX7002-1CB00

Load side
Rated operational currents Ie1)
Conventional thermal current Ith

Rated operational current Ie


acc. to utilization categories (IEC 60947-5-1)
AC-15

At 24 ... 230 V

DC-13

At 24 V
At 110 V
At 230 V

A
A
A

1
0.2
0.1

Switching current
for resistive load acc. to IEC 60947-5-1
AC-12

At 24 ... 230 V

DC-12

At 24 V
At 110 V
At 230 V

A
A
A

6
0.2
0.2

AC/DC

24 ... 250

Switching voltage
Min. contact load for 3TX700.-. . .02

1 V AC/DC/0.1 A

Mechanical endurance

Operating cycles 10 x 106

Electrical endurance at Ie

Operating cycles 1 x 105

Type

3TX7004-1B, -1L,
3TX7005-1L

3TX7004-.M,
3TX7005-.M,

Load side
Rated operational currents Ie1)
Conventional thermal current Ith

Rated operational current Ie


acc. to utilization categories (IEC 60947-5-1)
AC-15

At 24 ... 230 V

DC-13

At 24 V
At 110 V
At 230 V

A
A
A

1
0.2
0.1

Switching current for resistive load acc. to IEC 60947-5-1


AC-12

At 24 ... 230 V

DC-12

At 24 V
At 110 V
At 230 V

A
A
A

6
0.3
0.2

V
mA

30
20

17 ... 250

Power limit for hard gold-plating


Voltage
Current
Switching voltage

AC/DC

Min. switching voltage (reliability 1 ppm)


Standard contacts
Hard gold-plated contacts

17 V DC/5 mA
5 V DC/1 mA

Mechanical endurance

Operating cycles 10 x 106

Electrical endurance at Ie

Operating cycles 1 x 105

1)

Capacitive loads can result in micro-welding on the contacts.

Note:
If inductive loads are connected in parallel, the endurance of the
relay couplers can be increased.

5/40

Siemens IC 10 2014

0.5 x 106

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Relay couplers
Relay couplers circuit diagrams for 3TX7002, 3TX7003
Terminal designations acc. to EN 50005
Output/input coupling
links

Output coupling links

3TX7002-1AB00
3TX7002-1AB02
3TX7002-2A.00
3TX7002-2AF05

3TX7002-1BB00
3TX7002-1BF00

Input coupling links


3TX7002-1CB00

3TX7002-1FB02

3TX7002-2BF02

3TX7003-1CB00

3TX7003-1BB00

3TX7003-1AB00
A1

13

A1

14

A2 A2

A1 A1

12 14

A2 A2

NSB0_00189

NSB0_00188

13 23

A1

14 24

A2

11

21

NSB0_00192

NSB0_00191a

NSB0_00190

11

A1

12 14 22 24

12 14

A2

A2

11

Relay couplers circuit diagrams for 3TX7004, 3TX7005


Output coupling links

Input coupling links

3TX700.-1M.00

3TX700.-1BB00
3TX700.-1BF05

3TX700.-1L.0.

A1

A1
14

A1

A1

12
14

A2
13
NSB0_00205

3TX700.-1BB10

12
14

A2
11

A2
A2
NSB0_00207

11
11

NSB0_00208

3TX700.-2M.02

A
0
M

A1

A1

A2

14

12
14

A3

13
NSB0_00213

A2

A2
NSB0_00209

11
11

hGdGh
WGdGG
tGdGt

Siemens IC 10 2014

5/41

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Relay couplers

Selection and ordering data


AC and DC operation for snap-on mounting onto TH 35 standard mounting rail
Rated control supply
voltage Us
(at AC: 50/60 Hz)

Contacts
Version

NO

Width W

CO

DT

Article No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

mm

Relay coupling links 3TX7002


Screw terminals

Output coupling links

3TX7002-1AB00

24 AC/DC

--

11.5

3TX7002-1AB00

1 unit

41H

24 AC/DC

11)

--

11.5

3TX7002-1AB02

1 unit

41H

24 AC/DC

--

17.5

3TX7002-1BB00

1 unit

41H

230 AC/DC3)

--

17.5

3TX7002-1BF00

1 unit

41H

24 AC/DC

22)

--

22.5

3TX7002-1CB00

1 unit

41H

24 AC/DC

--

21) 2)

22.5

3TX7002-1FB02

1 unit

41H

24 AC/DC

--

11.5

3TX7002-2AB00

1 unit

41H

110 AC/DC4)

--

11.5

3TX7002-2AE00

1 unit

41H

230 AC/DC3)

12)

--

11.5

3TX7002-2AF00

1 unit

41H

230 AC/DC

12)

--

11.5

3TX7002-2AF05

1 unit

41H

230 AC/DC3)

--

11)

17.5

3TX7002-2BF02

1 unit

41H

Input coupling links

Relay coupling links 3TX7003


Output coupling links

Spring-type
terminals

24 AC/DC

--

11.5

3TX7003-1AB00

1 unit

41H

24 AC/DC

--

17.5

3TX7003-1BB00

1 unit

41H

24 AC/DC

22)

--

22.5

3TX7003-1CB00

1 unit

41H

--

11.5

3TX7003-2AF00

1 unit

41H

Input coupling links


230 AC/DC
3TX7003-1BB00
1)

Hard gold-plated contacts.

2)

Different potential up to 300 V permitted; no protective separation.

3)

Observe max. permissible cable length for AC control voltage: 7 m.

4)

Observe max. permissible cable length for AC control voltage: 15 m.

Note:
For coil voltages which are not listed, SITOP DC power supplies
can be used, e.g. 6EP1331-5BA00 or 6EP1331-5BA10;
see Chapter 15, "Stabilized Power Supplies" "SITOP Power
Supplies".
Note:
A clearance of at least 10 mm between the modules or to
adjacent contacts is required for operation with rated voltage
and 100 % ON period over 24 hours a day.

5/42

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Relay couplers
Rated control supply Contacts
voltage Us
Version
(at AC: 50/60 Hz)

NO

Manual-0automatic
switch for
testing
purposes

CO

Width W

DT Article No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

mm

3TX7004 relay couplers


Output coupling links
24 AC/DC

--

Without

6.2

3TX7004-1LB00

1 unit

41H

24 AC/DC

--

12)

Without

6.2

3TX7004-1LB02

1 unit

41H

24 AC/DC

--

With

12.5

3TX7004-1BB10

1 unit

41H

230 AC/DC

--

Without

6.2

3TX7004-1LF00

1 unit

41H

230 AC/DC

--

Without

12.51)

3TX7004-1BF05

1 unit

41H

24 AC/DC

--

Without

6.2

3TX7004-1MB00

1 unit

41H

230 AC/DC

--

Without

6.2

3TX7004-1MF00

1 unit

41H

24 AC/DC

12)

--

Without

6.2

3TX7004-2MB02

1 unit

41H

110 AC/DC

12)

--

Without

6.2

3TX7004-2ME02

1 unit

41H

230 AC/DC

12)

--

Without

6.2

3TX7004-2MF02

1 unit

41H

Input coupling links

3TX7005 relay couplers


Spring-type
terminals

Output coupling links

3TX7005-2MB02

24 AC/DC

--

Without

6.2

3TX7005-1LB00

1 unit

41H

24 AC/DC

--

12)

Without

6.2

3TX7005-1LB02

1 unit

41H

110 AC/DC3)

--

Without

6.2

3TX7005-1LN00

1 unit

41H

230 AC/DC

--

Without

6.2

3TX7005-1LF00

1 unit

41H

24 AC/DC

--

Without

6.2

3TX7005-1MB00

1 unit

41H

230 AC/DC

--

Without

6.2

3TX7005-1MF00

1 unit

41H

24 AC/DC

12)

--

Without

6.2

3TX7005-2MB02

1 unit

41H

230 AC/DC

12)

--

Without

6.2

3TX7005-2MF02

1 unit

41H

Input coupling links

1)

For long cables.

2)

Hard gold-plated contacts.

3)

Extended operating range 0.7 ... 1.25 x US.

Note:

Note:

For replacement products see 3RS18 coupling links with


industrial enclosure or other 3TX70 products.

A clearance of at least 10 mm between the modules or to adjacent contacts is required for operation with rated voltage and
100 % ON period over 24 hours a day.

For coil voltages which are not listed, SITOP DC power supplies
can be used, e.g. 6EP1331-5BA00 or 6EP1331-5BA10;
see Chapter 15, "Stabilized Power Supplies" "SITOP Power
Supplies".

Accessories
For coupling links

Version

DT Article No.

For linking the same potentials

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

3TX7004-8AA00

1 unit

41H

3TX7004-8BA00

1 unit

41H

Type

Connecting comb, blue


3TX7004

24 terminals,
current carrying capacity for infeed
max. 26 A
Width 6.2 mm

3TX7004-8AA00

Connecting cable, blue


3TX7002 and 3TX7004 with
screw terminals
3TX7003 and 3TX7005 with
spring-type terminals

With supply cable, blue


24 terminals,
current carrying capacity for infeed
max. 12 A
Length of cable between two terminals
approx. 11 cm

3TX7004-8BA00

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens IC 10 2014

5/43

3TX7004-1LB0.

Screw terminals

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Relay couplers with plug-in design

Overview

Benefits
Plug-in base couplers with spring-type terminals in width
6.2 mm
Fast exchange with existing wiring (plug-in relay)
Tested complete units shorter mounting time
Single relays available as components
The wire inlet and terminals can be reached from the front.
This results in faster wiring time and wiring errors are
prevented.
Linking of control supply voltage and control signals with
16-pole connecting comb
Galvanic isolation plate for isolating different voltages for
neighboring units
Integrated reverse polarity protection and
EMC arc-suppression diode
Clearly visible functional state of the relay coupler by yellow
LED
Protective separation according to IEC 61140
Device variants with hard gold-plated contacts, hence high
contact reliability
230 V AC/DC versions available

Coupling links are used to connect signals from and to a PLC.


The plug-in relays enable the relay to be replaced at the end of
its service life without detaching the wiring.
For easy linking of the signals, each terminal can be jumpered
using an external connecting comb.
Note:

A clearance of at least 10 mm between the modules or to adjacent contacts is required for operation with rated voltage and
100 % ON period over 24 hours a day.

Technical specifications
Type

3TX7014, 3TX7015
mm

6.2 x 90 x 92

mm

1 x 89.2 x 94.2

Rated insulation voltage Ui (pollution degree 2)

300

Protective separation
between coil and contacts acc. to IEC 60947-1, Appendix N

Up to 300 AC

C
C

-25 ... +55


-40 ... +80

Galvanic isolation plate 3TX7014-7CE00

Dimensions (W x H x D)

General technical specifications

Permissible ambient temperature


During operation
During storage
Degree of protection
Enclosure
Relays

IP20
IP40

Short-circuit protection
Short-circuit test with fuse links of operational class gG
with short-circuit current Ik = 1 kA acc. to IEC 60947-5-1

Conductor cross-sections
For 3TX7014:

Screw terminals

Solid
Finely stranded with or without end sleeve

mm2
mm2

1 x (0.5 ... 2.5)


1 x (0.5 ... 1.5)
M2.5
Screwdriver, 3.0 mm x 0.5 mm (3RA29 08-1A)

Terminal screws
- Corresponding opening tool
For 3TX7015:

Spring-type terminals

Solid or finely stranded


Finely stranded with end sleeve

mm2
2

mm

1 x (0.5 ... 2.5)


1 x (0.5 ... 1.5)

Corresponding opening tool

Screwdriver, 3.0 mm x 0.5 mm (3RA2908-1A)

Type

3TX701.-1.M

3TX701.-1.B

3TX701.-1.E

3TX701.-1.F

0.85 ... 1.1Us

0,7 ... 1.25 Us

0.8 ... 1.1 Us

0.8 ... 1.1 Us

Control side
Operating range
Power consumption, max.
At Us = 24 V
At Us = 115 V
At Us = 230 V
Protection circuit
DC
AC

5/44

Siemens IC 10 2014

W
W
W

0.5
0.5
1
Freewheel diode + Reverse polarity protection
Rectifier bridge

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Relay couplers with plug-in design
Type

3TX7014, 3TX7015

Load side
Rated currents1)
Conventional thermal current Ith

- AC-15

At 24 ... 230 V A

- DC-13

At 24 V A
At 110 V A
At 230 V A

Rated operational currents Ie


1
0.2
0.1

AC/DC V

Switching voltage

24 ... 250

Min. contact load (reliability 1 ppm)


Standard contact
Hard gold-plated contacts

17 V DC/5 mA
5 V DC/1 mA

Mechanical endurance

Operating cycles 10 x 106

Electrical endurance at Ie acc. to AC-15

Operating cycles 1 x 105

Note:

Capacitive loads can result in micro-welding on the contacts.

If inductive loads are connected in parallel, the endurance of the


relay couplers can be increased.
Connections
Terminal designations acc. to EN 50005
1 NO

1 CO contact

3TX7014-1AM00
3TX7015-1AM00

3TX7014-1B .. .
3TX7015-1B .. .

NO
14

(+)A1
COIL

13
COM

COIL NC NO
(-)A2 12 14

IC01_00208

COIL
-A2

13
COM
IC01_00207

+A1
COIL

Selection and ordering data


Rated control supply voltage Us
(at AC: 50/60 Hz)

Contacts
Version

DT Screw terminals

Article No.

NO

PU
(UNIT,
SET, M)

PS*

PG

Price
per PU

CO

Plug-in base couplers, width 6.2 mm,


complete with relay
24 DC

--

3TX7014-1AM00

5 units

41H

24 DC

--

3TX7014-1BM00

5 units

41H

24 AC/DC

--

3TX7014-1BB00

5 units

41H

115 AC/DC

--

3TX7014-1BE00

5 units

41H

230 AC/DC

--

3TX7014-1BF00

5 units

41H

24 DC

--

3TX7014-1BM02

5 units

41H

24 AC/DC

--

3TX7014-1BB02

5 units

41H

115 AC/DC

--

3TX7014-1BE02

5 units

41H

230 AC/DC

--

3TX7014-1BF02

5 units

41H

3TX7014-1AM00

With hard gold-plated contacts1)

1)

The versions with hard gold-plated contacts feature high contact reliability
(also for low currents) and are therefore especially suitable for solid-state
inputs of programmable logic controllers.

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens IC 10 2014

5/45

1)

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Relay couplers with plug-in design
Rated control supply voltage Us
(at AC: 50/60 Hz)

Contacts
Version

DT Spring-type
terminals
Article No.

NO

PU
(UNIT,
SET, M)

PS*

PG

Price
per PU

CO

Plug-in base couplers, width 6.2 mm,


complete with relay
24 DC

--

3TX7015-1AM00

5 units

41H

24 DC

--

3TX7015-1BM00

5 units

41H

24 AC/DC

--

3TX7015-1BB00

5 units

41H

115 AC/DC

--

3TX7015-1BE00

5 units

41H

230 AC/DC

--

3TX7015-1BF00

5 units

41H

With hard gold-plated contacts1)

1)

24 DC

--

3TX7015-1BM02

5 units

41H

24 AC/DC

--

3TX7015-1BB02

5 units

41H

115 AC/DC

--

3TX7015-1BE02

5 units

41H

230 AC/DC

--

3TX7015-1BF02

5 units

41H

The versions with hard gold-plated contacts feature high contact reliability
(also for low currents) and are therefore especially suitable for electronic
inputs of programmable logic controllers.

Accessories
For coupling links Rated control supply
voltage Us

Version

DT Article No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

Replacement relay modules, width 6.2 mm, 1 changeover contact


For complete unit
3TX7014 and
3TX7015

12 DC

3TX7014 and
3TX7015

24 DC

3TX7014 and
3TX7015

60 DC

24 V AC/DC

3TX7014-7BQ00

1 20 units

41H

24 V DC,
hard gold-plated

3TX7014-7BQ02

1 20 units

41H

24 V DC

3TX7014-7BM00

1 20 units

41H

24 V DC,
hard gold-plating

3TX7014-7BM02

1 20 units

41H

115 V or 230 V AC/DC

3TX7014-7BP00

1 20 units

41H

115 V or 230 V AC/DC, A


hard gold-plated

3TX7014-7BP02

1 20 units

41H

For linking the same


potentials

3TX7014-7AA00

5 units

41H

3TX7014-7CE00

1 10 units

41H

Connecting comb, blue


3TX7014 and
3TX7015

--

16 terminals,
current carrying capacity
for infeed max. 6 A

3TX7014-7AA00

Galvanic isolation plates


3TX7014 and
3TX7015

--

--

3TX7014-7CE00

Assignment of replacement relay modules


Plug-in base couplers

Replacement modules

Standard contacts

Hard gold-plated contacts

Us

Contact

Standard contacts

Hard gold-plated contacts

3TX701.-1AM00

--

24 V DC

1 NO

3TX7014-7BM00

--

3TX701.-1BM00

3TX701.-1BM02

24 V DC

1 CO contact

3TX7014-7BM00

3TX7014-7BM02

3TX701.-1BB00

3TX701.-1BB02

24 V AC/DC

3TX7014-7BQ00

3TX7014-7BQ02

3TX701.-1BE00

3TX701.-1BE02

115 V AC/DC

3TX7014-7BP00

3TX7014-7BP02

3TX701.-1BF00

3TX701.-1BF02

230 V AC/DC

3TX7014-7BP00

3TX7014-7BP02

More information about replacement relay modules


see Product Support:
http://support.automation.siemens.com/WW/view/en/34803536

5/46

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Semiconductor couplers

Overview
AC and DC operation

Surge suppression

IEC 60947, EN 60947,


IEC 60664-1, EN 60664-1 and EN 50005;
optocouplers: IEC 60747-5, EN 60747-5;
programmable controllers: IEC 61131-2

In the case of optocouplers, the contact element is a semiconductor. These are not subject to wear; so welding is not possible.

The input and output coupling links differ with regard to the positioning of the terminals and the LEDs. For equipment identification purposes, each coupling link has a blank labeling plate.

With semiconductors, the switching current is not dependent on


the inductance of the load, i.e. the switching current for a DC-13
load is the same as that for an inductive DC-12 load.

The semiconductor couplers have a low power consumption


and are therefore particularly well suited for solid-state systems.

This means that coupling links with a semiconductor output are


particularly suitable for inductive loads such as solenoid valves.
It is not relevant to specify any number of operating cycles because this does not affect the endurance of the semiconductor
provided it is not overheated.

In the coupling links in double-decker design, the connections


are arranged on two levels; these units are extremely compact.
For test purposes, versions are available with manual-0-automatic switches. This design can also be supplied with springtype terminals.

Note:

Technical specifications
Type

3TX7002

3TX7004, 3TX7005

mm

W x 60 x 62

W x 80 x 85

Rated insulation voltage Ui


(pollution degree 3)

300

Optoelectronic coupling elements:


Protective separation
acc. to IEC 60947-1, Appendix N

Up to 300

C
C

-25 ... +60


-40 ... +80

For width W see


"Selection and ordering data"

Dimensions (W x H x D)

General technical specifications

Permissible ambient temperature


During operation
During storage

Conductor cross-sections
For 3TX7002, 3TX7004:
Solid
Finely stranded with end sleeve

Screw terminals
mm2
2
mm

Terminal screws
- Corresponding opening tool

1 x (0.25 ... 4)
1 x (0.5 ... 2.5)
M3
Screwdriver, size 3.0 mm x 0.5 mm (3RA29 08-1A)

For 3TX7005:
Solid or finely stranded
Finely stranded with end sleeve
Corresponding opening tool

Spring-type terminals
mm2
2

mm

---

1 x (0.08 ... 2.5)


1 x (0.25 ... 1.5)

--

Screwdriver, size 3.0 mm x 0.5 mm


(3RA2908-1A)

Siemens IC 10 2014

5/47

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Semiconductor couplers
Type

3TX7002-3AB00

3TX7002-3AB01

3TX7002-4AB00

3TX7002-4AG00

17 ... 30 DC

11 ... 30 DC

17 ... 30 AC/DC

88 ... 264 AC

At 17 V DC
At 24 V DC
At 30 V DC

mA
mA
mA

18
20
22

5
7
8.5

----

----

At 17 V AC/DC
At 24 V AC/DC
At 30 V AC/DC

mA
mA
mA

----

----

10
14
18

----

At 88 V AC/DC
At 230 V AC/DC
At 264 V AC/DC

mA
mA
mA

----

----

----

9
24
28

Switching current

1.8

1.5 2)

0.1

0.1

Short-time loading capacity

A
ms

20
20

4
200

1
20

1
20

48 ... 264
--

- 60

- 30

- 30

Minimum load current

mA

60

--

--

--

Voltage drop conducting

1.5

1.1

1.7

0.3

Control side
Operating range
Power consumption, max.

Switching voltage (operating range)1)


Effective AC 50/60 Hz
DC

1)

Comply with minimum switching voltage for 3TX7002-3AB00.

2)

See derating diagram.

Type

3TX70043TX7005-

3AB04

3AC.4

3AC03

3PB54

3PB74

4PG24

3PG74

Control side
V

Operating range

110 ... 230 88 ... 253


AC/DC
AC/DC

11 ... 30 DC
Power consumption, max.
At 24 V DC
At 110 V DC
At 230 V AC

W
W
VA

0.5
---

Switching voltage

0.25
---

0.2
---

--1.5

-0.2
1.5

10 ... 48
DC

10 ... 30
DC

24 ... 250 10 ... 30


AC
DC

11 ... 30
DC

10 ... 30
DC

11 ... 30
DC

Switching current

0.5

1.5

0.1

1.5

100

Duration

ms

20

Shortcircuit
proof1)
--

Short-circuit proof2)

0.2

20

--

--

Shortcircuit
proof2)
--

Minimum load current

mA

--

5003)

50

--

--

--

--

Load side

Short-time loading capacity


Current

1)

In the event of a short circuit or overload, the semiconductor output


switches off. In order to operate the device again, it must be temporarily
disconnected from the power supply.

2)

In the event of a short circuit or overload, the current is limited by the


semiconductor output.

Derating diagram for 3TX7002-3AB01


(A)
Continuous
current per
channel
1,5

Separate
Between
2 modules
with 5 mm
clearance each
and 1 W power
loss each

0,5

NSB0_00187

Load side

20

40

60

u (C)

Load current as a function of ambient temperature Tu

5/48

Siemens IC 10 2014

3)

If the current falls below the minimum load current, the built-in semiconductor detects an open circuit in the load circuit. The control must be temporarily switched off for resetting.

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Semiconductor couplers
Semiconductor couplers circuit diagrams
Terminal designations acc. to EN 50005
Output coupling links

Input coupling links

3TX7002-3AB00
A1

3TX7002-3AB01
A1

13

3TX7002-4AB00
A1

13

3TX7002-4AG00
13

A1

14

A2

13

NSB0_00193
NSB0_00195

NSB0_00196

NSB0_00194

A2

14

14

A2

A2

14

Output coupling links


3TX700.-3PB54
3TX700.-3PG74
3TX700.-3PB74

A1

3TX700.-3AC04

3TX700.-3AB04
3TX700.-3PB41

A1

A1
+13

+13

A2

A1

+13
+13

A2
14
NSB0_00214

NSB0_00215

Load

0V

Load
_

A2

14
NSB0_00216

Output coupling links


3TX700.-3AC03

A1

A1
+13
+13

~13
~13

14
NSB0_00219

A2

~14
NSB0_00218

14
0V

+13
A2

A2
+

A2

NSB0_00217

Load
_

3TX700.-4AB04

A1

A
0
M
A1

A2

0V

Input coupling links

3TX700.-3AC14

A3

A2

14

Load
_

Load

~14
Load

hGdGh
WGdGG
tGdGt

Siemens IC 10 2014

5/49

Siemens AG 2013

Coupling Relays
3TX7 Coupling Relays, Narrow Design
Semiconductor couplers

Selection and ordering data


AC and DC operation For snap-on mounting onto TH 35 standard mounting rail
Rated control
supply voltage Us
(at AC: 50/60 Hz)

Switching
voltage

Switching Manual-0current
automatic
switch for
testing
purposes

Width W

mm

DT

Article No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

3TX7002 semiconductor couplers, 1 transistor


Screw terminals

Output coupling links


24 DC

48 ... 264 AC

1.8

--

11.5

3TX7002-3AB00

1 unit

41H

60 < DC

1.5

--

11.5

3TX7002-3AB01

1 unit

41H

Input coupling links


24 AC/DC

30 < DC

0.1

--

11.5

3TX7002-4AB00

1 unit

41H

110 240 AC

30 < DC

0.1

--

11.5

3TX7002-4AG00

1 unit

41H

3TX7002-3AB00

3TX7004 semiconductor couplers


Output coupling links

3TX7004-3AB04

24 DC

48 DC

0.5

--

6.2

3TX7004-3AB04

1 unit

41H

24 DC

11 ... 30 DC

1.5

--

6.2

3TX7004-3PB54

1 unit

41H

24 DC

30 DC

--

6.2

3TX7004-3PB74

1 unit

41H

110 ... 230 AC/DC

30 DC

--

6.2

3TX7004-3PG74

1 unit

41H

24 DC

30 DC

--

12.5

3TX7004-3AC04

1 unit

41H

24 DC

30 DC

Yes

12.5

3TX7004-3AC14

1 unit

41H

24 DC

24 ... 250 AC

--

12.5

3TX7004-3AC03

1 unit

41H

0.1

--

6.2

3TX7004-4PG24

1 unit

41H

Input coupling links


110 ... 230 AC/DC

30 DC

3TX7005 semiconductor couplers


Spring-type
terminals

Output coupling links

3TX7005-3AB04

24 DC

48 DC

0.5

--

6.2

3TX7005-3AB04

1 unit

41H

24 DC

11 ... 30 DC

1.5

--

6.2

3TX7005-3PB54

1 unit

41H

24 DC

30 DC

--

6.2

3TX7005-3PB74

1 unit

41H

110 ... 230 AC/DC

30 DC

--

6.2

3TX7005-3PG74

1 unit

41H

24 DC

30 DC

--

12.5

3TX7005-3AC04

1 unit

41H

24 DC

30 DC

Yes

12.5

3TX7005-3AC14

1 unit

41H

24 DC

24 ... 250 AC

--

12.5

3TX7005-3AC03

1 unit

41H

0.1

--

6.2

3TX7005-4PG24

1 unit

41H

Input coupling links


110 ... 230 AC/DC

30 DC

Note:
For replacement products, see 3RS18 coupling links with
industrial enclosure or other 3TX70 products.

For coil voltages which are not listed, SITOP DC power supplies
can be used, e.g. 6EP1331-5BA00 or 6EP1331-5BA10;
see Chapter 15, "Stabilized Power Supplies" "SITOP Power
Supplies".

Accessories
For coupling links

Version

DT Article No.

For linking the same potentials

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

3TX7004-8AA00

1 unit

41H

3TX7004-8BA00

1 unit

41H

Type

Connecting comb, blue


3TX7004

24 terminals,
current carrying capacity for infeed
max. 26 A
Width 6.2 mm

3TX7004-8AA00

Connecting cable, blue


3TX7002 and 3TX7004
with screw terminals
3TX7003 and 3TX7005
with spring-type terminals

With supply cable, blue


24 terminals,
current carrying capacity for infeed
max. 12 A
Length of cable between two terminals
approx. 11 cm

3TX7004-8BA00

5/50

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Coupling Relays
SIRIUS 3RS18 Coupling Relays with Industrial Enclosure
Relay couplers

Overview
Versions:
Wide voltage range: One connection for a wide voltage range
Combination voltage: Two connections for different voltage
ranges
Versions with solid-state compatible outputs
(hard gold-plating)
1, 2 or 3 changeover contacts

The 3RS18 coupling relays are couplers in the proven 22.5 mm


industrial enclosure. This enclosure supports the same connection methods as for the 3RP15 timing relays, including springtype connection; 2 wires can be clamped.
The series comprises devices with up to 3 changeover contacts
with screw terminals or spring-type terminals as combination
voltage or wide voltage range versions.
The relay coils are protected internally with noise suppression
diodes.

Technical specifications
Type

3RS1800-.A...

3RS1800-.B...

3RS1800-.H...

mm

22.5 x 86 x 84

22.5 x 86 x 94

22.5 x 86 x 103

Rated insulation voltage Ui pollution degree 3

500

Protective separation acc. to IEC 60947-1, Appendix N


between the coil and the contacts and between the individual contacts.

300

C
C

-25 ... +60


-40 ... +80

Dimensions (W x H x D)

General technical specifications

Permissible ambient temperature


During operation
During storage
Degree of protection acc. to IEC 60529
Enclosure
Cover

IP20
IP40

Short-circuit protection
A

Short-circuit test with fuse links of operational class gG


with short-circuit current Ik = 1 kA acc. to IEC 60947-5-1

Conductor cross-sections
For 3RS1800-1:

Screw terminals
mm2
mm2
mm2

Solid
Finely stranded with end sleeve
AWG cables, solid or stranded
Terminal screw
- Corresponding opening tool

1 x (0.5 ... 4); 2 x (0.5 ... 2.5)


2 x (0.5 ... 2.5)
2 x (20 ... 14)
M3.5
Screwdriver, size 3.0 mm x 0.5 mm (3RA29 08-1A)

Tightening torque

Nm

0.8 ... 1.2

For 3RS1800-2:

Spring-type terminals
mm2
mm2
mm2
AWG

Solid
Finely stranded without end sleeve
Finely stranded with end sleeve
AWG cables, solid or stranded

Corresponding opening tool

2 x (0.25 ... 1.5)


2 x (0.25 ... 1.5)
2 x (0.25 ... 1)
2 x (24 ... 16)
Screwdriver, size 3.0 mm x 0.5 mm (3RA2908-1A)

Control side
0.85 ... 1.1 x Us

Operating range
Power consumption, max.

AC or DC VA/W

8/1

Load side
A

Conventional thermal current Ith


Rated operational currents Ie
AC-15
DC-13

Switching current for resistive load


AC-12
DC-12

Switching voltage
Max. AC
Max. DC
Min. contact load
Standard contacts
Hard gold-plated contacts

At 24 ... 400 V
At 24 V A
At 110 V A
At 230 V A

3
1
0.2
0.1

At 24 ... 400 V
At 24 V
At 115 V
At 230 V

A
A
A
A

5
5
0.2
0.2

V
V

400
250
17 V DC, 5 mA at 1 ppm fault
5 V DC, 1 mA at 1 ppm fault

Mechanical endurance

Operating cycles 10 x 106

Electrical endurance at Ie

Operating cycles 1 x 105

Siemens IC 10 2014

5/51

Siemens AG 2013

Coupling Relays
SIRIUS 3RS18 Coupling Relays with Industrial Enclosure
Relay couplers
Circuit diagrams
Terminal designations acc. to EN 50005
3RS1800-.AP00,
3RS1800-.AQ00

3RS1800-.BP00,
3RS1800-.BQ00,
3RS1800-.BW00

A1 A3 11
A2

A1 A3 11
A2

12 14

3RS1800-.HP0.,
3RS1800-.HQ0.,
3RS1800-.HW0.
A1 A3 11

21

A2

12 14 22 24

21

31

12 14 22 24 32 34

Connection of the control supply voltage Us


3RS1800-..P0.,
3RS1800-..Q0.

3RS1800-..P0.,
3RS1800-..Q0.

3RS1800-..W0.

U S = 24 V AC/DC

U S = 110 ... 120 V AC


U S = 220 ... 240 V AC

U S = 24 ... 240 V AC/DC

L+

L+

L+

A2
L

A1

A1
NSB0_02225

A3

A2
L

A2
L

NSB0_02226

A1
NSB0_02224

A3

Note:
The position of the connection points on the device is based on
the principle of logical separation, i.e. the coil terminals A1, A2,
A3 are above and the terminals for the changeover contacts 11,
12, 14 etc. are below.

Selection and ordering data


Rated control supply Connection Us Contacts
voltage Us
Version
(at AC: 50/60 Hz)

DT Article No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

CO

Coupling relays in industrial enclosure, 22.5 mm


Screw terminals

Wide voltage range


24 ... 240 AC/DC

A1 - A2

2
3
31)

A
A
A

3RS1800-1BW00
3RS1800-1HW00
3RS1800-1HW01

1
1
1

1 unit
1 unit
1 unit

41H
41H
41H

Combination voltage
24 AC/DC and
110 ... 120 AC

A3 - A2 or
A1 - A2

1
2
3
31)

A
A
A
C

3RS1800-1AQ00
3RS1800-1BQ00
3RS1800-1HQ00
3RS1800-1HQ01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

41H
41H
41H
41H

24 AC/DC and
220 ... 240 AC

A3 - A2 or
A1 - A2

1
2
3
31)

A
A
A
A

3RS1800-1AP00
3RS1800-1BP00
3RS1800-1HP00
3RS1800-1HP01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

41H
41H
41H
41H

3RS1800-1H. . .

Coupling relays in industrial enclosure, 22.5 mm


Wide voltage range
24 ... 240 AC/DC

Spring-type
terminals
A1 - A2

2
3
31)

A
A
A

3RS1800-2BW00
3RS1800-2HW00
3RS1800-2HW01

1
1
1

1 unit
1 unit
1 unit

41H
41H
41H

Combination voltage
24 AC/DC and
110 ... 120 AC

A3 - A2 or
A1 - A2

1
2
3
31)

C
A
C
C

3RS1800-2AQ00
3RS1800-2BQ00
3RS1800-2HQ00
3RS1800-2HQ01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

41H
41H
41H
41H

24 AC/DC and
220 ... 240 AC

A3 - A2 or
A1 - A2

1
2
3
31)

A
A
A
A

3RS1800-2AP00
3RS1800-2BP00
3RS1800-2HP00
3RS1800-2HP01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

41H
41H
41H
41H

3RS1800-2B. . .

1)

Hard gold-plated contacts.

5/52

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Coupling Relays
Coupling Relays with LZS/LZX Plug-In Relays
Plug-in relay couplers

Overview
Function
The semiconductor couplers have a low power consumption
and are therefore particularly well suited for solid-state systems.
In the versions equipped with LEDs, these indicate the switching
state. The LZS:PT/MT plug-in relay couplers have a test button.
This can be used to force the plug-in relay coupler into the
switching state and to lock it. This is indicated by a raised
petrol-colored lever.

Logical separation
The terminals for the contacts and the terminals for the coil are
arranged on separate levels, e.g. above for contacts and below
for coil. Logical separation is not necessarily protective separation.
Protective separation
For safe isolation, transfer of the voltage of one circuit to another
circuit is prevented to a suitable degree of safety (requirements
and tests are described in IEC 60947-1 in Appendix N).

Control with solid-state output

Notes on the previous LZX series

In the case of solid-state outputs (e.g. proximity switches) with


overload and short-circuit protection, you must make allowance
during configuration for the temporarily flowing capacitor charging currents! This is possible, for example, by using a suitable
LZS plug-in relay coupler.

The complete units and accessory parts of the LZX series are no
longer listed in this catalog. The complete units of the LZS series
are fully compatible with the corresponding units of the LZX series. Prices for the LZS series are lower than for the previous LZX
series.

Surge suppression

The LZX plug-in relays are available unchanged and are used
accordingly in both the LZS and the LZX series.

The 24 V DC relays LZX:RT and LZX: PT with LEDs can be supplied with, all others without integral surge suppression (freewheel diode connected in parallel with A1/A2). The positive control supply voltage must be connected to coil terminal A1.
Mounting
The relays are plugged into the base and this is snapped onto a
TH 35 standard mounting rail according to IEC 60715.

Note:
Due to differences in geometry the LED modules, plug-in bases,
retaining brackets and labels can be combined and/or used in
only the respective series, LZS or LZX.
The LZS series offers not only service-proven screw connections
but also versions with plug-in terminals (push-in).

A retaining bracket can be ordered for the MT series that additionally fixes the relay into a plug-in base (under conditions of increased mechanical stress). For the RT and PT series, a combined retaining and ejection bracket is available which can be
used to disassemble the relay where access is difficult, for example, when relays are mounted side-by-side.
They can be mounted as required.

Siemens IC 10 2014

5/53

Plug-in relay coupling links can be ordered as complete units or


as individual modules for customer assembly.

Siemens AG 2013

Coupling Relays
Coupling Relays with LZS/LZX Plug-In Relays
Plug-in relay couplers

Technical specifications
Relay type

LZX:RT print relay, 8-pole,


(12.7 mm) 1 CO/2 CO

LZX:PT industrial relay, 8-, 11- and 14-pole,


(22.5 mm) 2 CO/3 CO/4 CO

mm

15.5 x 78 x 71

28 x 74 x 72

mm

15.5 x 77 x 71

28 x 77 x 79

mm

15.5 x 98 x 71

28 x 98 x 79

Rated control supply voltage Us1)

24 DC

Rated insulation voltage Ui


(pollution degree 3)

250

250

Overvoltage category
acc. to IEC 60664-1

III

III

Protective separation
between coil and contacts
acc. to IEC 60947-1, Appendix N

Up to 250 V (with plug-in base LZS:RT78726)


No (for complete units with standard socket)

No

IP67
IP20

IP50
IP20

-40 ... +70


-40 ... +80

-40 ... +70


-40 ... +80

Dimensions (W x H x D)

LZX:RT.D4 / LZX:PT.D5

LZX:RT.B4 / LZX:PT.B5

LZX:RT.A4 / LZX:PT.A5

General technical specifications

Degree of protection
Relays
Bases
Permissible ambient temperature
During operation
During storage

C
C

24 AC

115 AC

230 AC

24 DC

24 AC

115 AC

230 AC

Conductor cross-sections
Connection type

Screw terminals
mm2
2

Solid
Finely stranded with end sleeve
Corresponding opening tool

mm

Screw terminals

2 x 2.5
2 x 2.5
2 x 1.5
2 x 1.5
Screwdriver, size 3.0 ... 3.5 mm x 0.5 mm (3RA29 08-1A)

Connection type

Plug-in terminals (push-in)

Plug-in terminals (push-in)

mm2
mm2
mm2

1 x (0.75 ... 1.5), 2 x (0.75 ... 1.0), 2 x 1.5


1 x (0.75 ... 1.5), 2 x (0.75 ... 1.0), 2 x 1.5
1 x (0.75 ... 1.0), 2 x 0.75, 1 x 1.5

1 x (0.75 ... 1.5), 2 x (0.75 ... 1.0), 2 x 1.5


1 x (0.75 ... 1.5), 2 x (0.75 ... 1.0), 2 x 1.5
1 x (0.75 ... 1.0), 2 x 0.75, 1 x 1.5

Operating range at 20 C

16.8 ... 52

18 ... 52

18 ... 40.8

19.2 ... 39.6 92 ... 190

Power consumption at Us
AC
DC

VA
W

-0.4

0.75
--

-0.75

1
--

Release voltage

2.4

7.2

3.6

7.2

Freewheel
diode for
complete
unit

--

Freewheel
diode in
LED
module

--

Solid
Finely stranded without end sleeve
Finely stranded with end sleeve

Control side

Protection circuit

86.3 ... 127 172 ... 264

34.5

69

34.5

184 ... 380

69

Load side
Switching voltage
AC/DC

24 ... 250

24 ... 250

A
A
A
A
A

16
6
---

-12
10
6

Rated operational current Ie AC-15 acc. to A


utilization categories (IEC 60947-5-1)

RT3 (1 changeover contact): 6


RT4 (2 changeover contacts): 2.5

PT2 (2 changeover contacts): 5


PT3 (3 changeover contacts): 5
PT5 (4 changeover contacts): 4 (DC coils),
2 (AC coils)

Rated operational current Ie DC-13 with


suppressor diode acc. to utilization
categories (IEC 60947-5-1)

2 at 24 V
0.27 at 230 V

PT2, PT3: 5 at 24 V
PT5: 4 at 24 V
0.5 at 230 V

10

Standard 17 V, 10 mA;
hard gold-plated 17 V/0.1 mA

Standard 17 V, 10 mA;
hard gold-plated 20 mV/1 mA

Rated currents2)
Conventional thermal current Ith
- 1 CO contact
- 2 CO contacts
- 3 CO contacts
- 4 CO contacts

Short-circuit protection
Short-circuit test with fuse links of
operational class gG
with short-circuit current Ik = 1 kA
acc. to IEC 60947-5-1
DIAZED, type 5SB
Min. contact load
(reliability: 1 ppm)
Mechanical endurance

Operating cycles 30 x 106

Electrical endurance
(resistive load at 250 V AC)

Operating cycles 1 x 105

1)

10 x 106

AC voltages, 50 Hz; for 60 Hz operation, the lower response value must be


increased by 10 %; the power loss will reduce slightly.

5/54

Siemens IC 10 2014

10 x 106
1 x 105
2)

Capacitive loads can result in micro-welding on the contacts.

Siemens AG 2013

Coupling Relays
Coupling Relays with LZS/LZX Plug-In Relays
Plug-in relay couplers
Relay type
mm

36 x 69 x 36

Rated control supply voltage Us1)

24 DC

Rated insulation voltage Ui


(pollution degree 3)

250

Dimensions (W x H x D)

MT industrial relay, 11-pole


(35.5 mm) 3 CO

AC and DC operation

Overvoltage category
acc. to IEC 60664-1

III

Protective separation
between coil and contacts
acc. to IEC 60947-1, Appendix N

No

Degree of protection of relay/base


Relays
Bases

24 AC

115 AC

230 AC

-45 ... +50


-45 ... +80

-45 ... +50


-45 ... +80

-45 ... +50


-45 ... +80

92 ... 137

184 ... 264

46

92

Permissible ambient temperature


During operation
During storage

C
C

-40 ... +60


-45 ... +80

Conductor cross-sections
Connection type

Screw terminals
mm2
2

Solid
Finely stranded with or without end sleeve

mm

Corresponding opening tool

2 x 2.5
2 x 1.5
Screwdriver, size 1 or Pozidriv 1

Control side
Operating range at 20 C

18 ... 38

19.2 ... 38

Power consumption
AC
DC

VA
W

-1.2

2.3
--

Release voltage

2.4

9.6

--

Protection circuit

Load side
Switching voltage
AC/DC

24 ... 250

Conventional thermal current Ith

10

Rated operational current Ie /DC-13


acc. to utilization categories (IEC 60947-5-1)

2 at 24 V,
0.27 at 230 V

Rated operational current Ie /AC-15


acc. to utilization categories (IEC 60947-5-1)

5 at 24 V and 230 V

10

Rated currents2)

Short-circuit protection
Short-circuit test with
fuse links of operational class gG
with short-circuit current Ik = 1 kA acc. to IEC 60947-5-1
DIAZED, type 5SB

12 V DC/10 mA

Min. contact load


(reliability: 1 ppm)
Mechanical endurance

Operating cycles 20 x 106

Electrical endurance
(resistive load at 250 V AC)

Operating cycles 4 x 105

1)

AC voltages, 50 Hz; for 60 Hz operation, the lower response value must be


increased by 10 %; the power loss will reduce slightly.

2)

Capacitive loads can result in micro-welding on the contacts.

Siemens IC 10 2014

5/55

IP50
IP20

Siemens AG 2013

Coupling Relays
Coupling Relays with LZS/LZX Plug-In Relays
Plug-in relay couplers
Circuit diagrams

(4)
42
44
(8)

11(9)

41(12)

(13)A1

11(7)

21(8)

(1)
12
14
(5)

(3)
32
34
(6)

31(9)

(13)A1

A2(14)

A2(14)

LZX:RT4
2-pole

11(9)

(3)
32
34
(7)

(2)
22
24
(6)

21(10)

31(11)

(13)A1

(4)
42
44
(8)

41(12)

A2(14)

LZX:MT32
3-pole

LZX:RT3
1-pole

(2)
22
24
(5)

(1)
12
14
(4)

NSB0_01011a

(1)
12
14
(5)

LZX:PT520, LZX:PT570, LZX:PT580


4-pole

NSB0_00250a

LZX:PT370
3-pole

NSB0_00249a

LZX:PT270
2-pole

A1

12

11

14

A2

22

21

24

A1

12

11

14

A2

22

21

24

(5)
22
(4)12

(8)32

(3)14

(9)34

NSB0_00248a

NSB0_00247a

NSB0_00251a

(2)
A1

Note:
Values in brackets: Plug-in base designations
Without brackets: Contact/coil designations

5/56

(6) (7)
21 24

Siemens IC 10 2014

(1) (11)
11 31

(10)
A2

Siemens AG 2013

Coupling Relays
Coupling Relays with LZS/LZX Plug-In Relays
Plug-in relay couplers

Selection and ordering data


Version

Rated control supply Contacts, Width


voltage Us
number of
(at AC: 50/60 Hz)
CO
contacts
V

DT Article No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

mm

Complete units, 11- and 14-pole, PT series


Complete units with plug-in base
for snap-on mounting onto TH 35 standard mounting rail
comprising:
Coupling relays with plug-in relays
Standard plug-in base with screw terminals
LED module (version 24 V DC: LED module with freewheel diode)
Fixing/ejection brackets
Labels
3 CO contacts

24 DC
24 AC
115 AC
230 AC

28

A
A
A
A

LZS:PT3A5L24
LZS:PT3A5R24
LZS:PT3A5S15
LZS:PT3A5T30

1
1
1
1

5 units
5 units
5 units
5 units

41H
41H
41H
41H

4 CO contacts

24 DC
24 AC
115 AC
230 AC

28

A
A
A
A

LZS:PT5A5L24
LZS:PT5A5R24
LZS:PT5A5S15
LZS:PT5A5T30

1
1
1
1

5 units
5 units
5 units
5 units

41H
41H
41H
41H

A
A
A
A

LZS:PT5B5L24
LZS:PT5B5R24
LZS:PT5B5S15
LZS:PT5B5T30

1
1
1
1

5 units
5 units
5 units
5 units

41H
41H
41H
41H

LZS:PT3A5L24

Complete units with plug-in base


with logical separation
for snap-on mounting onto TH 35 standard mounting rail
comprising:
Coupling relays with plug-in relays
Plug-in base with logical separation and screw terminals
LED module (version 24 V DC: LED module with freewheel diode)
Fixing/ejection brackets
Labels
4 CO contacts

24 DC
24 AC
115 AC
230 AC

28

Complete units, 8- and 14-pole, PT series


Complete units with plug-in base
with logical separation
for snap-on mounting onto TH 35 standard mounting rail
comprising:
Coupling relays with plug-in relays
Plug-in base with logical separation and plug-in terminals (push-in)
LED module (version 24 V DC: LED module with freewheel diode)
Fixing/ejection brackets
Labels

Plug-in terminals
(push-in)

2 CO contacts

24 DC
230 AC

28

A
A

LZS:PT2D5L24
LZS:PT2D5T30

1
1

5 units
5 units

41H
41H

4 CO contacts

24 DC
24 AC
115 AC
230 AC

28

A
A
A
A

LZS:PT5D5L24
LZS:PT5D5R24
LZS:PT5D5S15
LZS:PT5D5T30

1
1
1
1

5 units
5 units
5 units
5 units

41H
41H
41H
41H

LZS:PT5D5L24

Note:
Logical separation: The terminals for the contacts and the terminals for the coil are arranged on separate levels, e.g. above for
contacts and below for the coil. Logical separation is not necessarily protective separation.
Protective separation: Protective separation prevents voltage of
one circuit affecting another circuit with sufficient protection
(IEC 61140).

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens IC 10 2014

5/57

Screw terminals

Siemens AG 2013

Coupling Relays
Coupling Relays with LZS/LZX Plug-In Relays
Plug-in relay couplers
Version

Rated control supply Contacts, Width


voltage Us
number of
at AC 50/60 Hz
CO
contacts
V

DT Article No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

mm

Individual modules for customer assembly, PT series


Industrial relays, 8-, 11-, and 14-pole
Mini industrial relays
With test bracket and mechanical
switch position indicator, without LED1)

LZX:PT370024

24 DC

2
3
4

22.5

}
}
}

LZX:PT270024
LZX:PT370024
LZX:PT570024

1
1
1

1 unit
1 unit
1 unit

41H
41H
41H

24 AC

2
3
4

22.5

}
A
}

LZX:PT270524
LZX:PT370524
LZX:PT570524

1
1
1

1 unit
1 unit
1 unit

41H
41H
41H

115 AC

2
3
4

22.5

C
A
}

LZX:PT270615
LZX:PT370615
LZX:PT570615

1
1
1

1 unit
1 unit
1 unit

41H
41H
41H

230 AC

2
3
4

22.5

}
}
}

LZX:PT270730
LZX:PT370730
LZX:PT570730

1
1
1

1 unit
1 unit
1 unit

41H
41H
41H

24 DC
230 AC

22.5

}
}

LZX:PT580024
LZX:PT580730

1
1

1 unit
1 unit

41H
41H

24 DC
230 AC

22.5

}
C

LZX:PT520024
LZX:PT520730

1
1

1 unit
1 unit

41H
41H

With hard gold-plating

Without test bracket

Plug-in bases for PT relays


Standard plug-in bases
for mounting onto TH 35 standard mounting rail
--

Screw terminals
2
3
4

28

}
}
}

LZS:PT78720
LZS:PT78730
LZS:PT78740

1
1
1

1 unit
1 unit
1 unit

41H
41H
41H

2
4

28

}
}

LZS:PT78722
LZS:PT78742

1
1

1 unit
1 unit

41H
41H

1
1

1 unit
1 unit

41H
41H

LZS:PT78740
Plug-in bases with logical separation
for mounting onto TH 35 standard mounting rail
--

LZS:PT78722
Plug-in terminals
(push-in)

Plug-in bases with logical separation


for mounting onto TH 35 standard mounting rail
--

2
4

28

}
}

LZS:PT7872P
LZS:PT7874P

LZS:PT7874P
1)

The test bracket is designed to be non-latching. If the test bracket is


pressed further until 90 has been reached, two small lugs break off and
the test bracket can be latched in position.

Note:
Logical separation: The terminals for the contacts and the terminals for the coil are arranged on separate levels, e.g. above for
contacts and below for the coil. Logical separation is not necessarily protective separation.
Protective separation: Protective separation prevents voltage of
one circuit affecting another circuit with sufficient protection
(IEC 61140).

5/58

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Coupling Relays
Coupling Relays with LZS/LZX Plug-In Relays
Plug-in relay couplers
Version

Rated control supply Contacts, Width


voltage Us
number of
at AC 50/60 Hz
CO
contacts
V

DT Article No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

mm

Individual modules for customer assembly, PT series


More individual modules
LED modules
Red
With freewheel diode

24 DC

LZS:PTML0024

1 unit

41H

Without freewheel diode

24 AC/DC

LZS:PTML0524

1 unit

41H

110 230 AC/DC

LZS:PTML0730

1 unit

41H

LZS:PTML0024

--

12.5

Green
24 DC

LZS:PTMG0024

1 unit

41H

24 AC

LZS:PTMG0524

1 unit

41H

110 230 AC/DC

LZS:PTMG0730

1 unit

41H

26

LZS:PT17021

100 10 units

41H

--

26

LZS:PT17024

100 10 units

41H

--

--

26

LZS:PT17040

100 10 units

41H

6 ... 60 AC

--

26

LZS:PTMU0524

1 unit

41H

LZS:PTMU0730

1 unit

41H

LZS:PTMT00A0

1 unit

41H

3TX7004-8BA00

1 unit

41H

LZS:PT170R6

1 10 units

41H

LZS:PT170P1

1 10 units

41H

--

12.5

Fixing/ejection brackets for PT base


with logical separation
Screw terminals and
plug-in terminals (push-in)

LZS:PT17021

With freewheel diode


Without freewheel diode

--

Fixing/ejection brackets for standard plug-in base


without logical separation
Screw terminals
Labels
LZS:PT17024
RC elements
LZS:PT17040

110 230 AC
Freewheel diodes with connection to A1
6 230 DC

--

26

Connecting cables, 24-pole


LZS:PTMU0730

Current carrying capacity 12 A,


with supply cable, blue
Connecting combs for PT screw base
6-pole,
10 A current carrying capacity, natural-colored
Connecting brackets for PT push-in base

3TX7004-8BA00

2-pole,
10 A current carrying capacity, natural-colored

Individual modules for customer assembly, MT series


Industrial relays, 11-pole
Industrial relays with test bracket

LZX:MT326024

Without LED
With LED

24 DC

35.5

A
}

LZX:MT321024
LZX:MT323024

1
1

1 unit
1 unit

41H
41H

Without LED
With LED

24 AC

35.5

A
C

LZX:MT326024
LZX:MT328024

1
1

1 unit
1 unit

41H
41H

Without LED
With LED

115 AC

35.5

C
C

LZX:MT326115
LZX:MT328115

1
1

1 unit
1 unit

41H
41H

Without LED
With LED

230 AC

35.5

A
A

LZX:MT326230
LZX:MT328230

1
1

1 unit
1 unit

41H
41H

Screw terminals

Plug-in bases
for mounting onto TH 35 standard mounting rail
--

38

LZS:MT78750

1 unit

41H

--

38

LZS:MT28800

1 unit

41H

Retaining brackets
--

LZS:MT78750

Note:

Note:

Logical separation: The terminals for the contacts and the terminals for the coil are arranged on separate levels, e.g. above for
contacts and below for the coil. Logical separation is not necessarily protective separation.

For coil voltages which are not listed, SITOP DC power supplies
can be used, e.g. 6EP1331-5BA00 or 6EP1331-5BA10;
see Chapter 15, "Stabilized Power Supplies" "SITOP Power
Supplies".

Protective separation: Protective separation prevents voltage of


one circuit affecting another circuit with sufficient protection
(IEC 61140).
* You can order this quantity or a multiple thereof.
Illustrations are approximate

Siemens IC 10 2014

5/59

Siemens AG 2013

Coupling Relays
Coupling Relays with LZS/LZX Plug-In Relays
Plug-in relay couplers
Version

Rated control supply Contacts, Width


voltage Us
number of
at AC 50/60 Hz
CO
contacts
V

DT Article No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

mm

Complete units, 8-pole, 5 mm pinning, RT series


Complete units with standard plug-in base
for snap-on mounting onto TH 35 standard mounting rail
comprising:
Coupling relays with plug-in relays
Standard plug-in base with screw terminals
LED module (version 24 V DC: LED module with freewheel diode)
Fixing/ejection brackets
Labels

Screw terminals

1 CO contact

24 DC
24 AC
115 AC
230 AC

15.5

A
A
A
A

LZS:RT3A4L24
LZS:RT3A4R24
LZS:RT3A4S15
LZS:RT3A4T30

1
1
1
1

5 units
5 units
5 units
5 units

41H
41H
41H
41H

2 CO contacts

24 DC
24 AC
115 AC
230 AC

15.5

A
A
A
A

LZS:RT4A4L24
LZS:RT4A4R24
LZS:RT4A4S15
LZS:RT4A4T30

1
1
1
1

5 units
5 units
5 units
5 units

41H
41H
41H
41H

LZS:RT4A4T30

Complete units with plug-in base


with logical separation
for snap-on mounting onto TH 35 standard mounting rail
comprising:
Coupling relays with plug-in relays
Plug-in base with logical separation and screw terminals
LED module (version 24 V DC: LED module with freewheel diode)
Fixing/ejection brackets
Labels
1 CO contact

24 DC
24 AC
115 AC
230 AC

15.5

A
A
A
A

LZS:RT3B4L24
LZS:RT3B4R24
LZS:RT3B4S15
LZS:RT3B4T30

1
1
1
1

5 units
5 units
5 units
5 units

41H
41H
41H
41H

2 CO contacts

24 DC
24 AC
115 AC
230 AC

15.5

A
A
A
A

LZS:RT4B4L24
LZS:RT4B4R24
LZS:RT4B4S15
LZS:RT4B4T30

1
1
1
1

5 units
5 units
5 units
5 units

41H
41H
41H
41H

LZS:RT4B4T30

Complete units with plug-in base


with logical separation
for snap-on mounting onto TH 35 standard mounting rail
comprising:
Coupling relays with plug-in relays
Plug-in base with logical separation and plug-in terminals (push-in)
LED module (version 24 V DC: LED module with freewheel diode)
Fixing/ejection brackets
Labels

LZS:RT3D4L24

Plug-in terminals
(push-in)

1 CO contact

24 DC
24 AC
115 AC
230 AC

15.5

A
A
A
A

LZS:RT3D4L24
LZS:RT3D4R24
LZS:RT3D4S15
LZS:RT3D4T30

1
1
1
1

5 units
5 units
5 units
5 units

41H
41H
41H
41H

2 CO contacts

24 DC
24 AC
115 AC
230 AC

15.5

A
A
A
A

LZS:RT4D4L24
LZS:RT4D4R24
LZS:RT4D4S15
LZS:RT4D4T30

1
1
1
1

5 units
5 units
5 units
5 units

41H
41H
41H
41H

Note:
Logical separation: The terminals for the contacts and the terminals for the coil are arranged on separate levels, e.g. above for
contacts and below for the coil. Logical separation is not necessarily protective separation.
Protective separation: Protective separation prevents voltage of
one circuit affecting another circuit with sufficient protection
(IEC 61140).

5/60

Siemens IC 10 2014

* You can order this quantity or a multiple thereof.


Illustrations are approximate

Siemens AG 2013

Coupling Relays
Coupling Relays with LZS/LZX Plug-In Relays
Plug-in relay couplers
Version

Rated control supply Contacts, Width


voltage Us
number of
at AC 50/60 Hz
CO
contacts
V

DT Article No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

mm

Individual modules for customer assembly, RT series


Print relays, 8-pole, 5 mm pinning
Print relays
with hard gold-plating
Version with 1 CO contact
LZX:RT314024

24 DC
230 AC

12.7

}
C

LZX:RT315024
LZX:RT315730

1
1

1 unit
1 unit

41H
41H

24 DC
24 AC
115 AC
230 AC

12.7

}
C
C
}

LZX:RT314024
LZX:RT314524
LZX:RT314615
LZX:RT314730

1
1
1
1

1 unit
1 unit
1 unit
1 unit

41H
41H
41H
41H

12 DC
24 DC

12.7

C
}

LZX:RT424012
LZX:RT424024

1
1

1 unit
1 unit

41H
41H

}
}
}

LZX:RT424524
LZX:RT424615
LZX:RT424730

1
1
1

1 unit
1 unit
1 unit

41H
41H
41H

Print relays

Version with 1 CO contact

Version with 2 CO contacts


LZS:RT78725

24 AC
115 AC
230 AC

Screw terminals

Standard plug-in bases


for mounting onto TH 35 standard mounting rail
--

--

15.5

LZS:RT78725

1 unit

41H

--

15.5

LZS:RT78726

1 unit

41H

Plug-in bases with logical separation


for mounting onto TH 35 standard mounting rail
-LZS:RT78726

Plug-in terminals
(push-in)

Plug-in bases with logical separation


for mounting onto TH 35 standard mounting rail
--

--

15.5

LZS:RT7872P

1 unit

41H

15.5

LZS:PTML0024

1 unit

41H

}
}

LZS:PTML0524
LZS:PTML0730

1
1

1 unit
1 unit

41H
41H

LZS:PTMG0024

1 unit

41H

}
}

LZS:PTMG0524
LZS:PTMG0730

1
1

1 unit
1 unit

41H
41H

LED modules
Red

LZS:RT7872P

With freewheel diode

24 DC

--

Without freewheel diode

24 AC/DC
110 ... 230 AC/DC

---

Green
With freewheel diode

24 DC

--

Without freewheel diode

24 AC/DC
110 ... 230 AC/DC

---

15.5

--

--

15.5

LZS:RT17016

100 10 units

41H

--

--

15.5

LZS:RT17040

100 10 units

41H

6 ... 60 AC
110 ... 230 AC

--

15.5

}
}

LZS:PTMU0524
LZS:PTMU0730

1
1

1 unit
1 unit

41H
41H

--

15.5

LZS:PTMT00A0

1 unit

41H

3TX7004-8BA00

1 unit

41H

LZS:RT170R8

1 10 units

41H

LZS:RT170P1

100 10 units

41H

LZS:PTML0024
Fixing/ejection brackets
for RT base
Labels
LZS:RT17016

RC elements

Freewheel diodes with connection to A1


LZS:RT17040

6 ... 230 DC
Connecting cables, 24-pole
Current carrying capacity 12 A,
with supply cable, blue
Connecting combs for RT screw base

LZS:PTMT0730

8-pole,
10 A current carrying capacity, natural-colored
Connecting brackets for PT push-in base
2-pole,
10 A current carrying capacity, natural-colored

3TX7004-8BA00

Note:
For coil voltages which are not listed, SITOP DC power supplies
can be used, e.g. 6EP1331-5BA00 or 6EP1331-5BA10;
* You can order this quantity or a multiple thereof.
Illustrations are approximate

see Chapter 15, "Stabilized Power Supplies" "SITOP Power


Supplies".
Siemens IC 10 2014

5/61

Siemens AG 2013

Coupling Relays
Coupling Relays with LZS/LZX Plug-In Relays
Plug-in relay couplers

More information
Notes on configuration
PT series

RT series

Mounting the LZS:PT17024 fixing/ejection bracket on the


standard plug-in base with LZS:PT787.0 screw terminal

Mounting the LZS:RT17016 fixing/ejection bracket on the


LZS:RT7872 plug-in base

2
1 Interlock
2 Direction of assembly

Mounting the coupling relay with plug-in relay

NSB0_01790a

NSB0_01788

1 Interlock
2 Direction of assembly
3 Direction of disassembly

Mounting the coupling relay with plug-in relay

NSB0_01890a

NSB0_01889

Note:

Note:

The LZS:PT17021 and LZS:PT17024 ejection brackets of the


coupling relays with plug-in relay are not status displays!

The LZS:RT17016 ejection brackets of the coupling relays with


plug-in relay are not status displays!

5/62

Siemens IC 10 2014

You might also like