Professional Documents
Culture Documents
SYSTEMS
304
INSTALLATION
306
Framing
306
CONSTRUCTION
DETAILS
307
INTRODUCTION
The ceilings in this section
are constructed using steel
studs as the ceiling joists.
are required.
303
KSC2
CEILING LINING: [Above side] 2 layers of 16mm FireShield
[Below side] 2 layers of 16mm FireShield
FRAME:
Steel studs as ceiling joists at either 300mm or 450mm spacing
[Span based on Serviceability UDL 0.35 kPa and maximum deection span/360 or 10mm]
[Ceiling joists are lipped C studs]
[Ceiling is non-trafcable]
FRL
120/120/120
rated from above
Stud Size
(mm)
Span
UDL 0.35 kPa (mm)
STUDS + 1 ROW OF NOGGINGS
Stud Depth
Stud BMT
SYSTEMS
Fire Report
FAR 2888
92
150
BOXED STUDS
300mm
Joist Spacing
450mm
Joist Spacing
300mm
Joist Spacing
450mm
Joist Spacing
0.75
3850
3550
4150
3830
1.15
4000
3710
0.75
4630
4310
5210
4800
1.15
4950
4580
90/90/90
rated from below
+60min RISF
No
Insulation
50mm
EarthWool
11 kg/m
156
49 (42)
55 (49)
214
51 (44)
55 (51)
Acoustic
Report
Day Design
3094-23
KSC3
CEILING LINING: [Above side] 2 layers of 16mm FireShield
[Below side] 3 layers of 16mm FireShield
FRAME:
Steel studs as ceiling joists at either 300mm or 450mm spacing
[Span based on Serviceability UDL 0.35 kPa and maximum deection span/360 or 10mm]
[Ceiling joists are lipped C studs]
[Ceiling is non-trafcable]
FRL
120/120/120
rated from above
and below
+60min RISF
Fire Report
97/1140
Stud Size
(mm)
Span
UDL 0.35 kPa (mm)
STUDS + 1 ROW OF NOGGINGS
Stud Depth
Stud BMT
300mm
Joist Spacing
450mm
Joist Spacing
300mm
Joist Spacing
450mm
Joist Spacing
92
0.75
1.15
3720
3870
3310
3570
4020
3700
150
0.75
1.15
4490
4810
4180
4440
5060
4660
No
Insulation
50mm
EarthWool
11 kg/m
172
52 (45)
57 (52)
230
54 (47)
57 (53)
Acoustic
Report
Day Design
309423
KSC5
CEILING LINING: [Above side] 2 layers of 16mm FireShield
[Below side] 1 layer of 10mm MastaShield
FRAME:
Steel studs as ceiling joists at either 300mm or 450mm spacing
[Span based on Serviceability UDL 0.35 kPa and maximum deection span/360 or 10mm]
[Ceiling joists are lipped C studs]
[Ceiling is non-trafcable]
Stud Size
(mm)
FRL
90/90/90
Span
UDL 0.35 kPa (mm)
STUDS + 1 ROW OF NOGGINGS
Stud Depth
Stud BMT
rated from
above only
Fire Report
FAR 2888
304
300mm
Joist Spacing
450mm
Joist Spacing
300mm
Joist Spacing
450mm
Joist Spacing
No
Insulation
50mm
EarthWool
11 kg/m
92
0.75
1.15
3900
4110
3580
3760
4310
3920
134
43 (33)
50 (41)
150
0.75
1.15
4900
5270
4510
4850
5570
5110
192
45 (34)
51 (44)
Acoustic
Report
Day Design
3094-23
KSC6
CEILING LINING: [Above side] 2 layers of 16mm FireShield
[Below side] Lining optional
FRAME:
Steel studs as ceiling joists at either 300mm or 450mm spacing
[Span based on Serviceability UDL 0.35 kPa and maximum deection span/360 or 10mm]
[Ceiling joists are lipped C studs]
[Ceiling is non-trafcable]
rated from
above only
Fire Report
FAR 2888
92
150
Stud BMT
BOXED STUDS
300mm
Joist Spacing
450mm
Joist Spacing
300mm
Joist Spacing
450mm
Joist Spacing
0.75
3600
3170
4140
3770
1.15
3890
3490
0.75
4680
4260
5460
5000
1.15
5130
4680
No
Insulation
124
35 (32)
182
35 (32)
Acoustic Report
Day Design
3094-23
FRL
60/60/60
Span
UDL 0.35 kPa (mm)
KSC7
CEILING LINING: [Above side] 3 layers of 13mm FireShield
[Below side] Lining optional
FRAME:
Steel studs as ceiling joists at either 300mm or 450mm spacing
[Span based on Serviceability UDL 0.35 kPa and maximum deection span/360 or 10mm]
[Ceiling joists are lipped C studs]
[Ceiling is non-trafcable]
Stud Size
(mm)
FRL
90/90/90
Span
UDL 0.35 kPa (mm)
STUDS + 1 ROW OF NOGGINGS
Stud Depth
Stud BMT
rated from
above only
Fire Report
FAR 2888
300mm
Joist Spacing
450mm
Joist Spacing
300mm
Joist Spacing
450mm
Joist Spacing
No
Insulation
92
0.75
1.15
3550
3860
3120
3460
4110
3750
131
37 (35)
150
0.75
1.15
4650
5090
4230
4650
5430
4960
189
37 (35)
Acoustic Report
Day Design
3094-23
KSC8
CEILING LINING: [Above side] 3 layers of 16mm FireShield
[Below side] Lining optional
FRAME:
Steel studs as ceiling joists at either 300mm or 450mm spacing
[Span based on Serviceability UDL 0.35 kPa and maximum deection span/360 or 10mm]
[Ceiling joists are lipped C studs]
[Ceiling is non-trafcable]
Stud Size
(mm)
FRL
120/120/120
Span
UDL 0.35 kPa (mm)
STUDS + 1 ROW OF NOGGINGS
Stud Depth
Stud BMT
rated from
above only
Fire Report
FAR 2888
300mm
Joist Spacing
450mm
Joist Spacing
300mm
Joist Spacing
450mm
Joist Spacing
No
Insulation
92
0.75
1.15
3340
3680
2930
3250
3930
3580
140
38 (36)
150
0.75
1.15
4440
4880
4030
4440
5200
4750
198
38 (36)
Acoustic Report
Day Design
3094-23
305
SYSTEMS
Stud Size
(mm)
FRAMING
MAXIMUM CEILING SPAN TABLE SINGLE SPAN ONLY LINED WITH PLASTERBOARD ON UNDERSIDE
Joist Depth
Joist BMT
1 x 10mm
(mm)
(mm)
Steel Studs at 600mm maximum centres
51
64
76
92
150
0.5
0.75
0.5
0.75
1.15
0.55
0.75
1.15
0.55
0.75
1.15
0.75
1.15
1835
2060
2145
2460
2775
2535
2820
3185
2935
3255
3680
4750
5380
2 x 10mm
1 x 13mm
2 x 13mm
3 x 13mm
1 x 16mm
2 x 16mm
3 x 16mm
1720
1935
2010
2305
2605
2375
2645
2990
2745
3055
3460
4460
5060
1800
2020
2100
2530
2785
2580
3005
3125
2870
3290
3615
4660
5285
1665
1880
1945
2335
2575
2365
2770
2900
2660
3030
3355
4325
4915
1565
1765
1830
2190
2415
2200
2590
2730
2500
2835
3160
4075
4630
1740
1960
2095
2470
2705
2500
2945
3025
2780
3195
3495
4510
5120
1580
1780
1860
2235
2450
2235
2650
2760
2525
2875
3190
4115
4675
1465
1655
1730
2065
2265
2045
2445
2565
2350
2645
2970
3635
4355
76
92
150
2010
2260
2350
2695
3035
2780
3090
3480
3210
3565
4020
5190
5860
1885
2125
2205
2530
2850
2605
2900
3275
3015
3350
3780
4880
5525
1975
2220
2305
2760
3045
2845
3265
3415
3165
3605
3975
5095
5760
1830
2060
2140
2550
2820
2615
3015
3175
2920
3330
3680
4740
5370
1720
1940
2010
2395
2650
2440
2825
2990
2745
3120
3460
4465
5065
1910
2150
2305
2690
2960
2760
3200
3310
3050
3505
3845
4935
5585
1735
1950
2080
2440
2690
2480
2895
3020
2775
3170
3495
4505
5115
1615
1820
1910
2260
2490
2280
2675
2815
2580
2930
3255
4195
4770
1960
2205
2290
2625
2960
2705
3010
3395
3130
3475
3920
5065
5720
2050
2300
2395
2855
3150
2955
3375
3540
3300
3740
4125
5285
5960
1900
2140
2220
2645
2925
2720
3120
3295
3035
3460
3825
4915
5560
1785
2015
2090
2480
2750
2540
2925
3105
2855
3245
3590
4630
5250
1985
2230
2395
2785
3065
2870
3310
3430
3185
3635
3995
5120
5785
1805
2030
2160
2530
2790
2585
2995
3135
2880
3295
3630
4675
5300
1675
1890
1980
2345
2590
2380
2770
2930
2680
3045
3375
4355
4945
2150
2415
2515
2875
3230
2965
3295
3705
3425
3800
4275
5525
6220
2250
2520
2625
3105
3430
3230
3655
3860
3635
4075
4500
5760
6475
2085
2340
2435
2880
3190
2980
3390
3600
3355
3780
4185
5370
6055
1960
2210
2295
2705
3005
2795
3185
3395
3140
3550
3940
5065
5725
2175
2440
2620
3030
3340
3145
3585
3745
3520
3970
4370
5585
6285
1980
2230
2375
2755
3045
2845
3255
3430
3175
3605
3985
5115
5775
1840
2075
2200
2560
2835
2625
3020
3195
2940
3345
3705
4770
5400
INSTALLATION: Framing
0.5
0.75
0.5
0.75
1.15
0.55
0.75
1.15
0.55
0.75
1.15
0.75
1.15
150
0.5
0.75
0.5
0.75
1.15
0.55
0.75
1.15
0.55
0.75
1.15
0.75
1.15
2090
2350
2445
2800
3145
2885
3205
3605
3335
3700
4165
5380
6065
0.5
0.75
0.5
0.75
1.15
0.55
0.75
1.15
0.55
0.75
1.15
0.75
1.15
2290
2570
2675
3060
3430
3160
3505
3930
3650
4040
4535
5865
6580
02
24
46
67
306
Masonry
wall
Stud used as
ceiling joist
Masonry
wall
Stud used as
ceiling joist
Wall
stud
Masonry
wall
60mm min
Stud used as
ceiling joist
Stud used as
ceiling joist
Use 2x16mm-10g
tek screws
Stud used as
ceiling joist
30mm max
CONSTRUCTION DETAILS
Use 2x16mm-10g
tek screws
Stud used as
ceiling joist
Stud used as
ceiling joist
307
5-10mm clearance to
plasterboard. Sealant required
to maintain acoustic integrity
Cornice cement
Masonry
wall
Cornice cement
5-10mm clearance to
plasterboard. Sealant required
to maintain acoustic integrity
Masonry
wall
Stud used as
ceiling joist
Masonry
wall
Stud used as
ceiling joist
308
Masonry
wall
Cornice cement
Wall
stud
Non-re rated
Plasterboard
Wall
stud
5-10mm clearance to
plasterboard. Sealant required
to maintain acoustic integrity
Stud used as
ceiling joist
Masonry
wall
FireShield
Masonry
wall
Non-trafcable
ceiling joist
Non-trafcable
ceiling joist
Load-bearing
Wall Stud
Load-bearing
Wall Stud
FireShield
CONSTRUCTION DETAILS
FireShield
Non-trafcable
ceiling joist
Load-bearing
Wall Stud
FireShield
309
FIRE RATED
STEEL STUD CEILING BUILT FROM UNDERSIDE ONLY ELEVATION VIEW
3 layers max
2 layers max
3 layers max
CONSTRUCTION DETAILS
450mm max
310
5-10mm clearance to
plasterboard. Fire sealant
required to maintain re
and acoustic integrity
Maximum
stud drop
1200mm
Masonry
wall
Span
1 x 13mm
1 x 16mm
2 x 13mm
2 x 16mm
1 x 10mm
1 x 13mm
1 x 16mm
2 x 13mm
2 x 16mm
1800
2020
1890
2530
2785
1935
3005
3125
1520
3210
3615
1795
4825
1740
1960
1545
2470
2705
1585
2945
3025
1205
2760
3495
1460
4245
1665
1880
1220
2335
2575
1255
2770
2900
910
2335
3355
1140
3700
1195
1780
755
2235
2450
790
2295
2760
485
1730
3190
685
2915
2535
2820
3185
2935
3255
3680
4330
5380
2580
3005
3125
2870
3290
3615
4040
5285
2500
2945
3025
2750
3195
3495
3520
5120
2365
2770
2900
2520
3030
3355
3035
4915
2200
2650
2760
2200
2875
3190
2335
4675
02
24
46
311
CONSTRUCTION DETAILS
Set external
corner bead