You are on page 1of 2

GE Power & Water

Distributed Power

LM2500+/LM2500+G4 Base
Gas Turbine (50 Hz)

fact sheet

Technology

on wide body jet liners, the LM2500 family is a hot-end drive,

LM2500+G4
Additional airflow and exhaust temperatures for more power
and efficiency
Capable of over 33 MW ISO
Gearbox for optimum 50 Hz efficiency

two-shaft gas turbine with a free power turbine.

Service

Baseload power capabilities of 1836 MW ISO


Thermal efficiencies from 37% to 39%
Unsurpassed reliability exceeding 99%

GE is the worlds largest aeroderivative service provider, with a

Experience

the LM2500+, and LM2500+G4 industrial, cogeneration, and oil

The LM2500+ and the LM2500+G4 take the proven technology


of the LM2500 Base gas turbine to higher power levels and
efficiencies. Derived from the CF6 family of aircraft engines used

global network of field service offices and fully equipped service


centers. A wide range of products and services are offered for

Maintaining a high degree of commonality with its flight-tested

and gas operators, including:

forerunners, the LM2500 family continues to build its reputation

Level IV Service Centers and overhaul capability in Houston,

as the most reliable industrial gas turbine generator in its class.

Texas; Rheden, the Netherlands, and Agotnes, Norway.

57 Million operating hours


More than 2,000 units
End users: mechanical drive and power generation for
industrial plants, pipelines, platforms and marine
Configurations: simple cycle, cogeneration and combined cycle

Conversions, Modifications and Upgrades (CM&Us) designed

Innovation

Spare or lease engine options

to enhance the efficiency, power output and reliability of


the LM2500+. Examples include Exhaust Flow Enhancer,
Wet/Dry Low Emissions (DLE) Upgrades; Inlet Conditioning,
Fuel Conversions and Remote Monitoring and Diagnostics.
Engine exchange programs

GE offers two models in the LM2500+ family of products:


LM2500+
Additional compressor stage for increased power output
and efficiency
Produces in excess of 29 MW ISO
Operates at 3000 or 3600 rpm without a gearbox

Rotable hot section and module exchange programs


Wide variety of contractual service agreements
This product offering, combined with GEs commitment to reduce
Service Center and outage turn times, may result in substantial
life-cycle cost savings for the plant owner/operator.

Performance
Model

Output

Heat Rate

MWe

Btu/kWh

Pressure Ratio
kJ/kWh

Power
Turbine Speed

Exhaust Flow

rpm

lb/sec

Exhaust Temperature
kg/sec

50 HZ
LM2500+PK

29.3

9,164

9,669

22.6

3,000

193.5

87.8

968

520

LM2500+PK*

29.3

9,669

10,157

22.8

3,000

197.0

89.5

911

488

LM2500+PPR DLE

30.0

9,182

9,686

23.1

3,000

195.1

88.7

982

528

LM2500+RC

33.2

8,814

9,300

23.0

3,600**

201.9

91.6

976

524

LM2500+RC*

36.1

9,247

9,756

24.4

3,600**

213.0

96.8

945

507

LM2500+RD DLE

32.9

8,835

9,322

23.1

3,600**

201.0

91.4

977

525

* water injection **gearbox


Notes: Performance based on 15C amb temp, 60% RH, sea level, no inlet/exhaust losses on natural gas fuel with no NOx media, unless otherwise specified. Avg engine. Turbine inlet temp, exhaust flow and
exhaust temp at ISO rating conditions. Generator output at 11.5 kV, 0.90 PF, gearbox where indicated.

10000

28000
26000
9500

24000

Heat Rate (kJ/kW

Electric Power Outpu

30000

22000
20000
-20.0

fact sheet

9000
-10.0

0.0

10.0

20.0

30.0

40.0

Ambient Temperature (C)

LM2500+ 50 Hz Output and Heat Rate


LM2500+ 50 Hz Output and Heat Rate

Package
10500

32000
30000

10000

28000
26000
9500

24000

Heat Rate (kJ/kWh)

Electric Power Output (kW)

34000

22000
20000
-20.0

9000
-10.0

0.0

10.0

20.0

30.0

40.0

Ambient Temperature (C)

LM2500+ 50 Hz Output and Heat Rate


LM2500+ G4 50 Hz Output and Heat Rate
36000
10000

34000
32000

9500

30000
28000

9000

Heat Rate (kJ/kWh)

Electric Power Output (kW)

Electro-hydraulic start

90 and 85 dBA near field

system

design

Ex II 3 G

Barrier inlet air filters

CE/ATEX certification

Inlet conditioning

Winterization to -39C

Evaporative cooling

On/Off-line water wash

Chilling

304SS or 316SS piping

Heating

materials

Control System
10500

38000

Digital control system with a

Remote monitoring and

human machine interface (HMI)

diagnostics

10-minute start capability

Remote display

Black start

Control house

Continuous emission monitoring

Motor control center

26000
24000
-20.0

Lube Oil System

8500
-10.0

0.0

10.0

20.0

30.0

40.0

Ambient Temperature (C)

Notes: Performance based on 60% RH, sea level, no inlet/exhaust losses on natural gas fuel with
no NOx media. Average engine. Turbine inlet temperature, exhaust flow and exhaust temp at ISO
rating conditions. Generator output at 11.5 kV, 0.90 PF with a gearbox.

LM2500+ 50 Hz Output and Heat Rate

38000
50 HZ
LM2500+ Generator Package

10500

Gas Turbine

10000

36000
34000

17-Stage
axial compressor
32000

9500

30000
1st
seven stages have variable stator vanes (VSV)
28000
Horizontal
split casing

9000

Heat Rate (kJ/kWh)

Electric Power Output (kW)

24 V and 125 V DC batteries

Air to oil coolers

Simplex shell and tube

First fill lubricants

coolers

Support
One-Year Parts/Service

Electronically Transmitted

Warranty

Drawings

Package Familiarization

Startup Technical

Training

Assistance

26000

Combustor
options
24000

8500

-10.0
Gas, -20.0
liquid, and
dual 0.0
fuel

10.0

20.0

30.0

40.0

Ambient Temperature (C)

Water or steam injection, or dry low emissions (DLE)


for NOx control
6-Stage power turbine
Turbine factory tested
Generator
Continuous duty 11.5 kV, 11.0 kV, or 10.5 kV
TEWAC, TEEAC, or air-cooled options
2-Pole, 3-phase brushless exciter
WPII weather protected
Voltage regulator and neutral side protection CTs
NEMA Class F insulation and Class B temperature rise

www.ge-distributedpower.com
Copyright 2013 General Electric Company. All rights reserved.
GEA18292B (12/2013)