TI170/TI175/TI390/TI395

UFPA Infrared Camera


User Manual
Please read carefully before first use

ZHEJIANG ULIRVISION TECHNOLOGY CO., LTD


Version: 1.0
IssueDate:Feb,2014

To Our Customer
Dear Customer:

Thank you for choosing TI Series Infrared Camera!

Please read this user manual carefully before first use. Also
please keep in a safe place for reference in the future.

Please operate with the recommended instructions in user
manual.

We reserve the right to change this user manual without
further notice.

The copyright owner is Zhejiang ULIRvision Technology Co.,
LTD

Sincerely,
ULIRvision Technical Support

WARNING
DO NOT OPEN OR EXCHANGE PARTS!
REPAIR ONLY CAN BE CONDUCTED BY STUFF!

NOTICE

In order not to cause malfunction or even damage the device


please do not direct the lens towards strong hightemperature
radiation source (such as the sun) whether the power is on or
off!

Avoid violent shock and impact during operation or transport.

Storage temperature is between 40 and 70. The device


must be kept in original packing case during transport.

Typical storage place is cool, dry, ventilated, and without strong


electromagnetic field.

Keep the lens surface off grease or any chemical substance


which would damage the lens. Close the lid after operation.

Please regularly backup data on PC to prevent potential data loss


and format the internal FLASH memory duly to make it operate
properly.

Table of Contents
1.ProductSummary1
1.1StandardItemList2
1.2OptionalItemList2
2.BatteryandCharger2
2.1ChargingBattery3
2.2DirectCharging3
2.3AttentionforUsingBatteryCharger3
3.PanelFunctionSummary3
3.1MainControlPanel4
3.2SideView7
3.3BottomView8
3.3LeftSideView8
4.QuickStartReference9
4.1BatterySetting9
4.2QuickOperations9
4.3MeasureTargetTemperature10
4.4InfraredImageandVoiceAnnotation10
4.5InfraredImagePlayback10
4.6TelephotoandWideanglelens11
4.7ConnecttoPC12
4.8VideoandAudiooutput12
5.OperationMenu13
5.1DisplaySummary13
5.2MainMenu15
5.2.1File16
Manage16
Save17
Record&Play17
Delete18
Format19
5.2.2Measure19
SpotMeasure20
LineMeasure22
HorizontalLineMeasure22
VerticalLineMeasure23
VerticalLineMeasure23
Area(Rect)Measure24
Parameters26
Emissivity26
Distance27
AdjustRatio27


AdjustTemp27
SaveSetting27
5.2.3Image28
ImageSetup28
AlarmSwitch29
AlarmTemp29
AlarmColor29
IsothermColor29
IsothermTemp29
Fusion30
FusionAttribute31
PIP32
PIPAttribute34
AlarmColor35
AnalysisSetup36
TempRange36
IRLens36
AmbientTemp37
Reference37
RefTemp37
ImageReverse37
ClearScreen37
L&S(Auto/ManualMode)37
5.2.4Setup38
SystemSetup38
Language39
AutoRectify39
AutoSave39
Video39
Transparence39
DisplayDevice39
ScreenSave40
PowerSave40
StorageMedium40
Time&Date41
FactoryDefault41
SystemInformation43
DiscInformation44
6. BuildingThermalImagingSummary44
7.TechnicalSpecification46
8.TechnicalSupport48
9.Appendix:EmissivityofRawMaterial50

ii

Disclaimer

LimitedWarranty
Each ULIRvision product is warranted to be free from defects in
material and workmanship under normal use and service. This
warrantyextendsonlytotheoriginalbuyerorendusercustomerofan
ULIRvisionauthorizedreseller,anddoesnotapplytofuses,disposable
batteries, or to any product which, in ULIRvisions opinion, has been
misused,altered,neglected,contaminated,ordamagedbyaccidentor
abnormal conditions of operation or handling. ULIRvision warrants
that product will operate substantially in accordance with its
functionalspecifications.ULIRvisiondoesnotwarrantthatproductwill
beerrorfreeoroperatewithoutinterruption.

ULIRvisions warranty obligation is limited, at ULIRvisions option, to


refundofthepurchasedprice,freeofchargerepair,orreplacementof
a defective product which is returned to an ULIRvision authorized
servicecenterwithinthewarrantyperiod.

QualityAssurance
The development and production of this product is qualified per
ISO9001standard.
THIS WARRANTY IS BUYERS SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU
OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. ULIRVISION SHALL NOT BE LIABLE FOR ANY
SPECIAL,INDIRECT,INCIDENTAL,ORCONSEQUENTIALDAMAGESORLOSSES,
INCLUDINGLOSSOFDATA,ARISINGFROMANYCAUSEORTHEORY.

2014ULIRvisionTechnologyCo.Allrightsreserved.
ii


1.

Product Summary

TheTI170/TI175/TI390/TI395InfraredCamera(equippedwithUncooled
Focal Plane Array Microbolometer) produces crisp thermal image and
accurate temperature reading to help increase system maintenance
quality and efficiency in many industries. TI170/TI175/TI390/TI395
Infrared Camera is packed with advance features, such as colored
thermal images, multimeasurement methods, realtime video, voice
annotation,soundandcoloralarm,IRfusion,BuiltinflashandSDcard
storages.

TypicalApplication:

Power Industry: Monitor and diagnose the condition of electrical


wire and equipment, detect power leak, and prevent system
malfunction.
Petrochemical Industry: oil pipeline check, material interface
detect, heat leakage, insulation structure and power equipment
detect.
FireProtection:forestfireprotectionandlatentfiresourcesearch,
selfignition prevention and detection of special material, electric
fireprecautiondetect.
Medical Application: Accurately measure human body
temperatureandanalyzetemperaturefielddistribution.
Building Industry: humidity, air leakage and insulation defects
detect.
Other Applications: Civil engineering, scientific research, and
railwayetc


1.1 Standard Item List
TI170/TI175/TI390/TI395 infrared camera comes with the following
standarditemsandaccessories:

Name

Quantity

InfraredCamera

1SET

LiIonBattery

2PCS

Charger

1PC

SDCard

1PC

SDCardReader

1PC

USBCable

1PC

VideoCable

1PC

Convertercable

1pc

UserManual

1PC

WarrantyCard

1PC

IRSeeSoftwareCD

1PC

Adapter

1PC

TransportCase

1PC

1.2 Optional Item List

Wideanglelens
Telephotolens


2.

Battery and Charger

Itisrecommendedtochargebatteryimmediatelywhendeviceindicates
low power, please read more about battery installation and removal
methodsonPage8.
DevicecomeswithtwosetsofLiIonbatteryandonebatterycharger.It
isstronglyrecommendedtooperateonlywiththeincludedbatteryand


charger.UseanyotherbrandchargerorLiIonbatterymaycausefireor
criticaldamage.
2.1 Charging Battery

Align the notch of the battery at the chargers mount, press the
battery downward gently along the triangular arrow, and fit it to
theend.
ConnectthechargertoanACoutlet,duringcharging,theredLED
willbeon,andwhenchargingiscompleted,thegreenLEDwillbe
oninstead.
Itisabout4hourstocompletelychargeonebattery.
2.2 Direct Charging
Itisavailabletochargethebuiltinbatterywiththeadapter;itisabout
4hourstofullychargearunoutbattery.Theindicatorindicatesorange
inchargingandremainsgreenwhenfullycharged.

2.3 Attention for Using Battery Charger

3.

BatteryChargingcanonlybeconductedinsideofahouse.
Donotshortcircuitthebattery.
Donotputthebatteryinhightemperatureenvironment(60).
Neverdisassemblethebatteryorputitintofire,whichmaycause
explosion.
Donottrytomodifythebatteryorthecharger.
LiIonbatteryhasnomemoryeffect,chargingcanbeconductedat
anytime.
Please remove the charger from AD socketas soon ascharging is
completed.

Panel Function Summary


Inthismanual,longpressmeansLongpressbuttondownforabout2
seconds,andpressorshortpressmeanspressandrelease.
3.1 Main Control Panel

1. Power LED Light


After infrared camera is turned on, the indicator functions as a power
indicatoringreen;functionsasachargingindicatorinorange,indicating
thebatteryisbeingchargednow.

2. HotKey button 1
Presstoautomaticallyfocus,andLongpresstoturnon/offLEDlight.
4

3. HotKey button 2
Press to switch between measured objects (point, line and area), PIP
and fusion zone, setting range of thermal superposing temperature,
colorcode,temperatureupperandlowerlimits;andLongpresstoturn
on/offthelaser.
4, 5, 6,7 Direction buttons
Up( ),Down( ),Left( ),andRight( )keyshavedifferentusages
indifferentmodes.
Inmainmenu,directionbuttonsareusedformovingselecteditemsor
changing slidebar value. In real time Infrared view mode, directions
buttonsprovideoneclickaccess.

PressLeft(

)andRight(

)toselectpreviewimages.

PressLeft( )tofreezeInfraredimageandpressagaintounfreeze.
PressUp( ),orDown( )toswitchbetweennormalviewand18x
zoomcontinuous

AfterpressHotkeybutton2inareameasure(inyellowflashing):

Select measured spots: press Up ( ), Down ( ), Left ( ), and


Right( )buttontomovethespotinthesamedirection.
Select the measure line and sampling line; press Up ( ), Down
( ),Left(
direction.

),andRight(

)buttontomovethelineinthesame

Select area box: in move menu, press Up (

), Down (

), Left

( ), and Right ( ) buttons to move area box, and in size menu,


pressUp( )andDown( )toresizetheverticaldirectionarea


box,pressLeft(
box.

)andRight(

)buttonstoresizehorizontalarea

SelectPIParea:inPIPmode,pressUp( ),Down( ),Left( ),


and Right ( ) buttons to move infrared image area at same
direction;pressUp( ),Down( )buttonstoresizeverticalPIP

area;andpressLeft( )andRight( )buttonstoresizehorizontal


PIParea.
Selectfusionarea:infusionmode,pressUp( )andDown( )

buttons to select slidebar, and press the Left ( ) and Right ( )


keys to set the fusion upper or lower limit, as well as the
temperaturevaluesaboveorbelowthefusiontemperature.
SelectColorPaletteortemperaturemeasurementlimit:PressLeft

( )andRight( )tochangeColorPalette;andPressUp( )and


Down( )buttonstochangetemperaturelimit.

(Menu / Enter) button


8.
Thisbuttonhasdifferentfunctionsunderdifferentconditions:
1).InrealtimeInfraredviewmode,pressthisbuttontoopenthemain
menu.
2).Inthemenumode,pressthekeytoconfirmoperation.
3).In real time Infrared view mode, long press this button to manually
rectify measurement result, LCD screen will display the word
rectifying.
4).Inimageviewingmode,longpressthisbuttontoexit.
Afterautorectifying,ifdevicehasabnormalnoise,longpress
buttontoperformmanualrectifyingusuallysolvessuchissues.

9, 10, Manual Focus (T / W) button


PressT/Wbuttontomanuallyfocustogetbetterthermalimagewhen
autofocusthermalimageisnotgoodenough.


11, 12, CW / CCW imaging mode switch
Press the button to switch image models among infrared, visible, PIP,
fusion,WIW.

13. Shutter key


Pressthebuttontosavethecurrentimage.

3.2 Side View

14. Power ON/OFF button


Longpressthisbuttontopoweron/offthedevice.

15. Multifunctional interface for audio output or video output


Please insert converter cable. It can be connected to headphones to
listentheplaybackaudionotesasanalogaudiooutputinterface;Itcan
beconnectedtothemonitortoplayvideosasavideooutputinterface.

16. SD card interface


MICRO4GBSDcardcanbeinsertedintotheinterfacetoexpandstorage
volume.


17. USB Interface
Standard USB interface can be connected to the computer for data
transmission.

3.3 Bottom View

18. External DC In
ExternalDCrequirementisDC5V.
19. Screw nut on tripod
Sizeofscrewnutontripod 1/4_20.

3.3 Left Side View

20.3.2"Color270tiltableLCD
8


4. Quick Start Reference
4.1 Battery Setting
Insert and move in the lithium battery as indicated direction, user can
easilyinsertandmovethebattery.

BatteryInstallation

BatteryRemoval

4.2 Quick Operations

Insertthebatterycorrectly.
Long press Power button until the LED light is on, and wait until
systemfinishesinitialization.
SlideIRLensliddown,pointtotarget,andadjustfocustogetcrisp
thermalimage.
buttontorectifythermalimage.
Longpressthe
9


4.3 Measure Target Temperature

Pointdevicetomeasurementtarget,andpressHotKeybutton1to
autofocus. On the upperright LCD corner, *= displays the

spot measurement result. For better accuracy, long press


buttontoperformmanualrectify.
Select Area (Rect) Measurement to measure max, min, and
averagetemperaturewithinarectanglebox.
It is recommended to press button to freeze thermal image
first, and then apply different and detailed analysis. Press
buttononemoretimetounfreeze.
When measure result is outside standard temperature range,
screen display changes to indicate either below or above
temperature range. E.g.: 175/395 is with 20 ~ 250 , then the
CameraWillDisplay>250.0or<20.0toPromptUsers.

4.4 Infrared Image and Voice Annotation

Each thermal image can save up to 40 seconds voice annotation


data.ImageandvoiceannotationcanlaterbereviewedonPCby
bundledIRSeesoftware.Tosaveinfraredimage,presstheShutter
buttonwhileaccessingthetargetimage,thenaVoicedialogbox
appears, select Cancel, then press the Enter key, the image file
has been saved; select the Record, then press the Enter key,
bothimageandvoicefileshavebeensaved.
In main menu, press the Enter key to File Save provides the
samefunction.
:SelectCancelduringvoicerecordingtoexit.
4.5 Infrared Image Playback

PresstheEnterbuttontoenterthemainmenu.
SelecttheMainMenuFileManage,andthenselectthefile
directoryandfilename,thethumbnailimageofthestoredimage
10

is displayed, then press the Enter button to enter the viewing


state.
When viewing thermal image, press the Left ( ) or Right ( )
buttontoswitchthermalimageinthesamefolder.
The iconindicatesvoiceannotationattachedtocurrentthermal
image.PressEnterbuttontoenterFileVoice,thenselectPlay
toplayback.
LongpresstheEnterbuttontoreturntherealtimeimagingmode.

4.6 Telephoto and Wideangle lens

Thedevicecanbeequippedwithtelephotolensorwideangle
lens. Put lens in accord withthe dots(Figure 1) in line, then turn
lensinclockwisedirectiontilltothetwodotsinline(Figure2).
Thedotonthelens

Thedotonthedevicefrontpart

Figure 1

Thedotonthelens
Thedotonthedevicebody

Figure 2
11


EnterImageAnalysisSettingIRLensmenu,pressthe or
buttontoadjustthecorrespondinglens.
OperateImageSaveandImagePlaybackaccordingtothesteps
mentionedin4.4and4.5hereinabove.

4.7 Connect to PC
Connect device to PC using included USB cable. its available to to
export,delete,andformatthedatasavedinthebuiltinFLASHmemory
orontheSDcard.

4.8 Video and Audio output

Insert Converter cable to Multifunctional interface for audio


outputorvideooutput,connectMonitortoConvertercableusing
Videocable,EnterSetupSystemSetupDisplayDevice,
PresstheLeft( )orRight( )toswitchtoMonitorintheDisplay
Device,thengetthermalimageintheMonitor.

InsertConvertercabletoMultifunctionalinterfaceforaudio
outputorvideooutput,theninsertCommonearphoneto
Convertercable,finallytunevoiceannotationaccordingto4.5.
12


5. Operation Menu
5.1 Display Summary
AllitemscanbeselectedbyshortpressingHotKey2button
(Note: Long press Hotkey 2 button will turn on/off laser sight). The
selected item is flashing in yellow color. If no operation in 2 seconds
afterselection,Hotkeymodewillexitautomatically.

RealtimeThermalImageInterface

Autofocus:PressHotkey1buttonforautofocus.
Area Measure Box: 3 areas can be selected in area measure box;
entertheMainMenuMeasureRecttooperate.
AF Area: objects need focused can be displayed in the area to
achieveAutofocusingeffect.
Horizontalmeasuringline:Horizontalsamplingline,EntertheMain
MenuMeasureLinetoselectthefunction.
Temperature distribution curve: sample temperature distribution
curveofthemeasureline.

1.
2.
3.
4.
5.

6.

Point measure cursor: 4 measure points can be selected. Enable


13


7.

8.

theMainMenuMeasureSpottooperate.
Symbolfor18Xdigitalzoom:displaythemultipleofdigitalzoom,
undertherealtimemeasurementmodeorthepreviewmode,click
the
or
keytochangeinfraredimagesstepbystepinthe
multipleof0.1.
1,
2,
3 and
4indicatestemperature
Pointmeasure:

valueofpoint1,2,3and4respectively.
Imaging mode: Infrared, visual, PIP, fusion, and WIW can be
switchedbypressingthe or button.
10. Line measure: the temperature value in the crossing of measure
lineandcursorline.
11. Area measure: measure points within the area (maximum,
minimumoraveragetemperatureisoptional)
12,18. Lower or upper limit temperature: the lower and upper limit
temperatureofthecolorcodeatthesametime.
13. Storage medium: IN indicates builtin FLASH, SD means SD card;
enter the Main menu Setup System Setup Storage
Mediumtoadjustthestoragemedium.
14. USB symbol: USB0 means file transmission, USB1 means video
transmission; enter the Main menu Setup System Setup
USBtoswitch.
15.ColorCode:colorpalette.Anykindofcolorcodeisavailablein
thepalette.
16.TimeDisplay:itdisplaysthedefaultdateandtime.
17.Batterycondition:indicatescurrentbatterypowercondition.
19.Temperatureunit:therearethreeoptions:K.entertheMain
MenuImageAnalysisSetupTempunittoswitch.
20.Radiance:Theinfraredcamerasetofradiance.

9.

14


5.2 Main Menu
Menuandsubmenuitems:

EntertheMainMenu:
Long press Enter button (when not in Hotkey mode) to enter main
menu as shown below, not if press Enter button too long, instead of
entermainmenu,triggersmanualrectify.

MainMenu

15


Using
or
button to select menu item, and selected item is
highlighted with white background. Press Enter or button to enter
submenu, press button to return to the previous menu or exit.
(The key is unavailable to switch under a submenu consisting of
leftorrightswitchableoptions).

5.2.1 File
Using File menu to save, playback, and delete thermal image, or add
voiceannotationorformatdisk.

FileSubmenu
Manage
SelectManagetopreviewthermalimage,addoreditvoiceannotation,
ordeletethermalimage.

FileManage
16


Folderisautomaticallycreatedifnotexistwhensavingthermalimage.
FoldernameisMYYMMDD,andYYMMDDisyear,month,anddate.For
example, Jan2nd,2009 folder is M090102. All thermal images taken in
this day is saved in this folder. Thermal image file name is Phhmmss,
and hhmmss is hour, minute, second (according to system time). For
example,P080502infolderM090102meansthethermalimagetakenat
8:05:02timeinJan2nd,2009.
and
button to select items.
In File Manage window, press
Press or buttontoswitchfolderorfilewhenhighlighted.After
selectingthermalimage,pressEnterkeytoOpentoviewthermalimage
or press Enter key to delete it, and press Exit to exit File Manage
window.

ThermalImagepreview
Save
Save realtime thermal image. The operation method is the same as
Shutterbutton.

Record & Play


The Voice menu is used for recording, playing back, save and cancel
operations.
The iconindicatesvoiceannotationdatawithcurrentthermalimage.
17


If voice annotation already exists, press Record will record new voice
annotation and erase previously saved one. Press Cancel first to stop
recordingthenpressSavetosave.

VoiceAnnotation

Delete
Enter the delete menu, a dialog box pops up prompt, select the Ok
optionandpresstheEnterkeytodeletethethermalimage.

Deletesavedthermalimage

LongpresstheEnterkeytoexitthepreviewmode.

18


Format
FormatthebuiltinFLASHorSDcard.WhenPressEnterbuttontoMain
Menu Setup System Setup Storage Medium to select the
Internal,thenformatthebuiltinFLASH;toselecttheSDtoformat
theSDcard.Aftertheoptionisselected,adialogboxpopsupprompt
whether to format the disk? press the Ok option to immediately
formatsaveddata,pressCanceloptiontoexit.

Formatsavedthermalimage

Once FLASH or SD card is formatted, all saved data will be


permanentlydeleted,pleaseensurethatthedatahasbeentransferred
toPCbeforeformat.
Ifthesystemfailstosaveimages,pleasesearchandkillviruses,and
ifnovirusisfound,pleasebackupdatabeforeformatting.

5.2.2 Measure
Thereare5items:Spot,Line,Area(Rect),Parameters,andSaveSetting
inMeasuremenu.

19

MeasureSubmenu

SpotMeasure
Press or button to select or deselect. Selected spot is check
marked.Upto4spotscanbeselectedatthesametime.

SpotTargetSelection

20

SpotMeasure

Measure result on upperright LCD corner is temperature reading at


locationmarkedwith .Upto4spotscanbeselected.

SpotMeasureAttribute
PressHotkeybutton2untilspotmarkerisflashinginyellow,andthen
press Up ( ), Down ( ), Left ( ) and Right ( ) buttons to move
spot location to different directions, press Enter button to enter
Attribute Menu to set the emissivity and reference point. After 2
seconds with no operation, system will exit to real time Infrared view
screen.

SpotMeasureAttribute
21


Emissivity:RefertoAppendixEmissivityofrawmaterials.

SetReference:Setcurrentspotasreferencepoint.Ifselected,all
measureresultwillberelativevaluetothisspottemperature.

Line Measure
Thereare2linemeasureoptions:verticalandhorizontal.

HorizontalLineMeasure

HorizontalLineMeasure

Horizontallineistemperaturesamplingline,andupperrightLCDcorner
displays temperature measurement reading on vertical cursor line
intersection.AfterusingHotKeybutton2selectlinemeasure,press

and
buttontoadjustsamplinglineposition,andpress and
button to adjust cursor line position. Press Enter button to enter
AttributeMenu.After2secondswithnooperation,systemwillexitto
realtimeInfraredviewscreen.

22

HorizontalLineMeasureAttribute

VerticalLineMeasure

VerticalLineMeasure

Vertical line is temperature sampling line, and upperright LCD corner


displays temperature measurement reading on horizontal cursor line
intersection.AfterusingHotKeybutton2selectlinemeasure,press
and buttontoadjustsamplinglineposition,andpress
and

button to adjust cursor line position. Press Enter button to enter


AttributeMenu.After2secondswithnooperation,systemwillexitto
realtimeInfraredviewscreen.

23

VerticalLineMeasureAttribute

Emissivity:RefertoAppendixEmissivityofrawmaterials.

Area (Rect) Measure


Press and button to select or deselect. Selected Area is check
marked.Upto3areascanbeselected.

Area(Rect)TargetSelection

24

Area(Rect)Measure

Measure result on upperright LCD corner is the temperature


measurement result within the corresponding rectangle. There are 3
measuretypes:max,min,andaveragetemperature.

Area(Rect)MeasureAttribute
PresstheHotKeybutton2untilarearectangleisflashinginyellow.
PressEnterbuttontoenterAttributeMenuinwhichfourparameters
canbeadjustednamely:emissivity,setreference,measuretype,move
/size.

Area(Rect)MeasureAttribute
25


Emissivity:RefertoAppendix:Emissivityofrawmaterials.

Set Reference: Set current area as reference. If selected, all measure


resultwillberelativevaluetothistemperature.

MeasureType:Selectfrommax,min,andaverage.

Adjust:Adjustrectanglepositionandsize.

Parameters
Changedifferentsettingstoadjusttemperaturemeasurementaccuracy.
Press
and
buttontoselectdifferentparameters,andpress
and buttontochangevalue.

ParameterSubmenu

Emissivity
Emissivityvariesbasedontargetsubjectmaterial,surfacetemperature,
surfaceroughness,measurementangle,andetc.Press or once
to change Emissivity by 0.01. Long press
Emissivityin0.1intervals.
26

or

will change


Distance
Thisvaluecanbeomittediftargetsubjectisclosetodevice(lessthan
10m). Otherwise, set Distance value accordingly to get more accurate
temperature reading. Press or once to change Distance 0.1m.
Longpress or willchangeDistancein1minterval.

Humidity
This value can be omitted if target is close to device (less than 10m).
Otherwise, set Humidity value according to environmental condition.
Press or once to change Humidity 1%. Long press or
willchangeHumidityin10%interval.

AdjustRatio
Due to long time usage of device, the sensitivity of IR detector may
decrease.Insuchcase,itisnecessarytoadjustratiovaluetogetmore
accurate temperature reading. During calibration, if temperature
reading is higher than actual target temperature, change ratio value
lower,andviseversa.Press or oncetochangeratiovalue0.01.
Longpress or willchangeratiovaluein0.1intervals.

AdjustTemp
Under certain condition, it is necessary to adjust temperature reading
by a predefine value. Normally this option should be left unchanged.
Press or once to change 0.1. Long press or will
changethisvaluein1interval.

Save Setting
All parameter changes must be saved before power off device.
Otherwise,changeswillnotbesavedfornextpoweron.

27


5.2.3 Image
There are 5 items: Image Setup, Analysis Setup, Image Reverse, Clear
Screen,andL&S(Auto/Manual)inImageMenu.

Imagesubmenu

Image Setup

ImageSetupSubmenu

28


AlarmSwitch
Press or turnsonoroffthealarmfunction.IftheAlarmSwitch
ison,whentargetsubjectwithinareaboxhassurfacetemperatureover
Alarm Temp, device will alarm with buzzer sound and mark the high
temperaturelocationasAlarmColorifAlarmColorisset.

AlarmTemp
WhenAlarmSwitchisoff,thisoptionisdisabled.WhenAlarmSwitchis
on, Alarm Temp is the desired alarm temperature. Press or
once to change Alarm Temp 0.1. Long press or will change
AlarmTempin1interval.Defaultsettingis37.0.

AlarmColor
Alarm Color can select as: Auto, Black, White, Red, Orange, Yellow,
Green,Blue,Gray,andPurple.DefaultsettingisAuto,whichisnocolor
alarm.

IsothermColor
When this option is Auto, there is no Isothermal display. Otherwise,
target subject Infrared image will change to selected color when
temperature is within the range of (Isothermal Temp Isothermal
Width/2).DefaultsettingisAuto.

IsothermTemp
Press or oncetochangeIsothermalTemp0.1.Longpress
or willchangeIsothermalTempin1interval.

IsothermWidth
AdjustIsothermalWidthtochangetherangeofIsothermalColordisplay.
29


Press or oncetochangeIsothermalWidth0.1.Longpress
or will change Isothermal Width in 1 interval. Default setting is
1.0.

Fusion
Overlayinfraredimagepartlyonvisualimage,whichisconvenientto
identifyandanalyzeinfraredimage.
There are 3 modes to setup target area to infrared image, the other
areatovisualimage.
Press or buttontoselectAbove,Below,Intervaloffusion.

Interval:IfselectIntervaltype,itisnecessarytosettheupperlimit
of interval and lower limit of interval; Press or to change
0.1,Longpress or tochangein1interval.
Infrared image overlays visual image between two specified
temperature.

Above:ifselectAbovetype,itshalladjustabovetemperaturelevel;
Press
or
to change 0.1, Long press
or
to
changein1interval.
Infraredimageoverlaysvisualimageabovespecifiedtemperature.

30

Below:IfselectBelowtype;itshalladjustbelowtemperaturelevel;
or
to change 0.1, Long press
or
to
Press
changein1interval.
Infraredimageoverlaysvisualimagebelowspecifiedtemperature.

FusionAttribute

In Fusion mode, Press Hotkey button 2, the interval area is flashing in


yellow,thenpressEnterbuttontopopupdialogbox,itisavailableto
adjust Fusion Type, Upper limit of interval, Lower limit of interval,
Abovetemperature,Belowtemperature.
31

FusionAttribute

PIP
Scaling infrared image overlaying visual image, the fusion has 4 types:
PIPAuto,1/2PIP,1/4PIP,and3/4PIP.

automatic

32

1/2PIP

1/4PIP

3/4PIP
33


PIPAttribute
UnderPIPmode,pressHotkeybutton2toswitchuntilthewordPIPis
flashinginyellow,thenPressEnterbuttontopopupdialogbox,toset
PIP Mixing Ratio, Position / Size. After 2 seconds with no operation,
systemwillexittorealtimeInfraredviewscreen.

PIPAttribute

Mixingproportion:press

or

tosetAuto,1/2,1/4,3/4mode.

Adjust:selectSizetoconfirm,press

buttonstoadjust

PIP boxs size; select Position to confirm, press


,
, ,
buttonstoadjustPIPboxsposition.After2secondswithnooperation,
systemwillexittorealtimeInfraredviewscreen.

Dewpointalarm(availableonlyforTI170/TI390)

34


Dewpointalarm:press

or

buttontoturnon/offdewpoint

alarmfunction.IftheAlarmSwitchison,manuallyadjustthecurrent
ambienttemperatureandhumidity,thecorrespondingdewpoint
temperaturecanbeindicatedonthelowerleftcornerofscreen;ifthe
dewpointtemperaturevalueexceedsthepresettemperature,device
willalarmwithsettingalarmcolor.

AlarmColor
Alarm Color can select as: Auto, Black, White, Red, Orange, Yellow,
Green,Blue,Gray,andPurple.DefaultsettingisAuto,whichisnocolor
alarm.

Dewpointtemperatureshownonlowerleftcorner

dewpointtemperaturecanbedefinedasatemperatureofair
cooledtosaturationinthecasethatboththewatervaporcontentand
pressureinairareconsistent,whichisrelatedtoambienttemperature
andhumidity.
35


Analysis Setup

AnalysisSetupSubmenu

TempRange
SelectTemprangebaseonmeasuretargettemperature.
175/395standardTemprangeis20to250,extratemprange
(20/600)ortemprange(20/1200)iscustomizedservice.
TI170/TI390temprangeisonlyfrom20to100.

IRLens
For TI170/175 infrared camera, there are 3 options: 11mm (standard
lens),5.5mm(wideanglelens),and22mm(telephotolens);
ForTI390/395infraredcamera,thereare3options:21.5mm(standard
lens),11mm(wideanglelens),and40mm(telephotolens).
Press or buttontoselectcorrectIRlensforbestmeasurement
resultafterinstallingoptionalIRlens,forexample,ifremovewideangle
lens / telephoto lens from device, the device is with standard lens,
pleaseset11mmor21.5mm.

Thecameramayneed20secondstoreadjustanewlensbeforeit
canworkproperly.
36


TempUnit
Press or toselectTemperatureUnitfrom,,andK.
=9/5*+32K=273.15+

AmbientTemp
For more accurate measure result, set Ambient Temp to correct
environmental temperature. Press
Temp 0.1. Long press
interval.

Reference

or

or

once to change Ambient

will change Ambient Temp in 1

Setreferencespotorareatodisplaymeasureresultsasrelativevalue.

RefTemp
Press or oncetochangeRefTemp0.1.Longpress or
willchangeRefTempin1interval.Thisoptionisonlyactivewhenset
RefTempasreference.

Image Reverse
PressEnterbuttontoreversepaletteforthermalimagedisplay.Press
Enteragaintoswitchback.

Clear Screen
PressEnterbuttontoclearallitemsatthermalimagearea.

L&S (Auto/Manual Mode)


Press Enter button to switch between auto and manual rectifying. In
manual rectifying mode, upperleft corner of LCD display shows L&S,
andpress

or

toadjustuppertemplimitandlowertemplimit.
37


5.2.4 Setup
There are5 items in Setupmenu: System Setup, Time&Date,Factory
Default,SystemInformationandDiscInformation.

Setup Sub-menu

SystemSetup
There are 10 options in System Setup menu: Language, Auto Rectify,
Auto Save, Video, Transparence, Display Device, Screen Save, Power
and
buttontoswitch
Save,USB,andStorageMedium.Press
selection, press and button to adjust value, active item is
highlightedwithredbackground.

SystemSetupSubmenu

38


Language
Thereare10differentlanguageoptions:SimplifiedChinese,Traditional
Chinese, English, Korean, Japanese, German, French, Russian, Italian,
PortugueseandSpanish.

AutoRectify
Set the number of seconds to perform next autorectify. Set value
between 1 and 3000 seconds. Value 0 means disabling autorectify
feature.

AutoSave
Set the number of seconds to perform next autosave. Set value
between7to3600seconds.Value0meansdisablingautosavefeature.
Press or oncetochangethevalueby1second.Longpress
or willchangethevaluein10intervals.

Video

SelectbetweenPALandNTSC.

Transparence
Settoenableordisablemenutransparencefeature.

DisplayDevice
SelectbetweenLCDdisplayandexternalmonitordevice.Onlyonevideo
output device can be selected at one time, the other one will be
disabled.
: If accidentally selected external monitor device and LCD display is
disabled,poweroffandpowerondevicetogetLCDdisplayback.

39


ScreenSave
Set the number of minutes without operation to trigger disabling LCD
displaytosavepower.Selectbetween5min,10min,30min,andNone.

PowerSave
Set the number of minutes without operation to trigger power off
completely.Selectbetween10min,20min,30min,andNone.

USB
File Transmission and Video Transmission, press or button to
switchoptions.IfselectFiletransmission,deviceisusedasaUdiskto
export,delete,orformatthedatasavedonthebuiltinFLASHorSDcard
to PC; If select Video, device is used to transmit the realtime video
imagestoPCviaIRSeesoftware.
AftersetupIRSeeReportSuiteandUSBdeviceconditiontovideo
mode,theUSBdevicecanbeusedasacameraforinfraredandvisible
light.Forexample,clickthevideoconnectionkeyandafterawhile,the
videoconversationwillbeachievedviaMSN,Skype,QQetc.whenthe
videosourceisonlyfromThermalImagingCamera.Ifthesourcesare
twoormore,pleasechooseTIUSBamongdevicenamesandthedevice
namescanpopupafterpressedvideoconnectionkey.

StorageMedium
StorageMediumincludesInternalandSDcard,press or button
toswitchoptions.ThecapacityofBuiltinFLASHis256M,thecapacityof
standardSDcardis4GB,andthediskformatisFAT.
DeviceonlyidentifyFATformatSDcard,notanyotherformat.

40


Time & Date
Set system date and time. Press

or

button to select an item,

press or button to change its value and press Enter button to


confirm. If LiIon battery is removed for a long time, it is necessary to
resetsystemtimeanddate.

TimeSetting

Factory Default
Restorefactorydefaultandrectifysomeimpropersettings.

41


Parameters List of Default settings

Items
Parameters
Spot1234
area12
MeasuredTarget
area3
Measuringline
Emissivity
Distance
Measurement
Humidity
Parameters
Correctionfactor
Correctiontemperature
Alarm
Alarmtemperature
Alarmcolor,isothermal
color,etc.
ImageSettings Isothermaltemperature
Isothermalheight
Fusion type
PIP
Dewpointalarm

AnalysisSettings

42

Value/function
Disenabled
Disenabled
enabled
None
0.96
1.5
60
1.00
0.0
Disenabled
37.0
Auto

37.0
1.0
Interval
Auto
Disenabled
TI170/390:20/100
Temperaturerange
TI175/395:20/250
11mm170/175
Lens
21.5mm390/395
Temperatureunit

Ambienttemperature
Manual
Referencemeasurement Disenabled
Referencetemperature 30.0


Continued: Parameters List of Default settings

Items

SystemSettings

TimeSettings

Parameters
Languages
Automaticcorrection
Automaticstorage
Videoformat
MenuTransparency
DisplayMode
ScreenAutoclose
USB
storagemedia
Time

Value/function
English
150S
0S
PAL
Enabled
Screen
None
Filetransmissionmode
Flash
Nochange

System Information
Select to display system information, such as: serial number, software
version,andproductiondateetc.

43


Disc Information
SelecttodisplayDiscInformationasfollows:thedialogboxcanindicate
theFLASHsuseddiscspaceandfreespace,aswellasusedspace,free
spaceofSDcard.

DiscInformation

6.

Building Thermal Imaging Summary

As the quality of life improves and the lowcarbon life style becomes
known,higherdemandsarebeingsetonbuildings.Thefeaturesofour
TI series IR camera make it possible to detect slight temperature
differenceandtoanalyzeindoorhumidityandleakage.Hereinafterare
imagesinsomecases.

Theeffectdrawingofbuildingdetection
44

Theeffectdrawingofindoorhumidity

Theeffectdrawingofindoorpipeheatleakage

Theeffectdrawingofindoorcornerairleakage
45


7. Technical Specification
Type
IR
Resolution
Detector
PixelSpacing
StandardLens

OptionalLens

SpatialResolution
Image
Quality

ThermalSensitivity
Framefrequency
Focusing
DigitalZoom
SpectralRange
Visiblecamera
Spotlight
Display

Display

Imagemodes

TemperatureRange

Measure

Accuracy
Measurerectification
MeasureMode

46

NewUFPAmicrobolometer
170/175 160120
390/395 384288
25m
170/175 2116/0.15m
390/395 2116/0.4m
Wideangle :4232/0.1m
170/175
telephotolens :108/1m
Wideangle:3828/0.3m
390/395
telephotolens:118.5/1.2m
170/175 2.3mrad
390/395 1.2mrad
170/175 <60mk@+30
390/395 <80mk@+30
50/60Hz
Auto/Motor
0.1continuoussteppingzoomwithin
170/175
14multiples
0.1continuoussteppingzoomwithin
390/395
18multiples
814m
3M pixel
10cd/m
3.2"Color270tiltableLCD
InfraredVisualFusion
PIP(pictureinpicture)WIW
170/390 20+100
20+250(Standard)
175/395 20+600OptionalA
20+1200OptionalB
2 or2%(readingrange),selectthebigger
value
Auto/Manual
4spots,3areasavailableunderrealtime
mode(max,minandaveragetemp)line
measure,isothermaldisplay,tempdifference
measureandtempalarm(sound/color).


ContinuedTechnicalspecifications
ColorPalette
ImageSetup

SystemSetup
Measure
EmissivityRectification
Ambient TempRectification
AtmosphericTrans
Correction
Dewpointalarm
StorageMedia(Builtin
Memory)

Storage

4GBMicroSDCard

12Colorsselectable(includingironred,
rainbow,blackwhite,etc.)
Auto/Manualadjustcontrast,brightness
Date,Time,TemperatureUnit//K10
Languagesavailable,namely:Chinese
(simplified&traditional),English,Italian,
Japanese,Russian,French,German,Korean,
SpanishandPortuguese.
Adjustablefrom0.01to1.0
Auto,accordingtobackgroundtemperature
input
Auto,accordingtodistance,relativehumidity,
ambienttemperatureinput
Availableonlyfor170andTI390
TI170/175
Upto700images
TI390/395
Upto500images
TI170/175

Upto11200images

USB

USB

TI390/395
Upto8000images
Auto/Manualsingleframeimagestorage
JPEG,with14bitsmeasuredata
40Secondsvoicerecording
perimage(builtinmicrophone)
Filedownload,videotransmission

Laser

Director
BatteryType
BatteryOperatingTime
Chargingtype
PowerSave
ExternalPower
OperationTemp
StorageTemp
Humidity
ProtectionGrade

Class2,1mW/635nmRed
RechargeableLiIonBattery
3Hours(Undernormaltemperature)
Intelligentcharger
Included
5V5% DC
20~+50
40~+70
90 (noncondensing)
IP50

Shock

25G,IEC60068229

Vibration
Weight
Size(LWH)

2G,IEC6006826
410g
128mm62mm154mm

StorageMode
FileType
VoiceAnnotation

Power
Supply

Operatin
g
Conditio
n

Physical

47


8. Technical Support
For common mistakes and issues during operation, please refer the
followingform.Ifissuecannotberesolved,pleasecontactourtechnical
supportdepartment.

For simple problems arising during operation, please refer to the


following table. If the problem cannot be settled, please cut off the
powerandcontactourtechnicaldepartment.

Problem

CauseandSolution

Cameracannot be
poweredon

Devicepoweroff
automatically

Batterypowerissoon
usedup

Nothermalimage
Thermalimageisblack
andwhite

48

Nobatteryorbatteriesarenotinstalled
correctlyInstallbatterycorrectly.
Batterypowerisusedup.
Changebatteryorrecharge.
Savepowermode
poweronafter5seconds.

Batterypowerisusedup.
Changebattery.

Ambienttemperatureistoohighorlow.
Batteryisnotfullycharged.
rechargebatteryfully.
Batterymayalreadyreachendoflife.(300
usagecycles)
usenewbatterytocharge.

Lenslidisclosed.
Removelenslid.

Black&whitepalettemaybeselected.
restorefactorydefault.


Failures

CausesandSolutions

Thebatteryisuninstalledorimproperly
installed
Insertthebattery;orreinstallthebattery.
Theinfraredcameracannot

Thebatteryrunsout
start
Replaceorchargethebattery.

infraredcameraautoshutdown
Wait5secondsandthenrestart.

Theinfraredcamerashuts

Thebatteryrunsout
downautomatically
Replacethebattery.

Ambienttemperatureistoolowortoohigh.

Therechargeablebatteryisnotfullycharged
Rechargetherechargeablebattery.
Batterypower runsout

Thelifeofbatteryisalmostover,about300
fast
cyclesofchargeanddischargeforthetypeof
battery
Replacerechargeablebattery

nothermalimagedisplayed
thermalimageturnsblack&
white

Lenscapisnotopenopenthelenscap.

Checkifblackandwhitecolorcodeisselected
reloaddefaultsettings.

49


9.Appendix:EmissivityofRawMaterial
Forreferencepurposeonly
Material

Surface

Temp()

Emissivity()

inoxidized
Oxidized
Brownpolished

100
100
20

0.20
0.55
0.40

Unpolished
Oxidized
Oxidizedbadly

38
100
20

0.22
0.61
0.78

Iron

Oxidized
Rusted

100
25

0.74
0.65

CastIron

Oxidized
inoxidized

200
100

0.64
0.21

Nickel
StainlessSteel

Rough
Polished
Oxidized

25
38
200

0.94
0.28
0.37

Oxidized

60

0.85

Steel
Brick

800Oxidized

200
20

0.79
0.93

Concrete
Glass

Smoothflat
White
NaturalBlack

20
20
100
100

0.92
0.94
0.92
0.97

Smokyblack
Candlesmoke
Blackleadrough
16Coloraverage
White

Polished

Human
Fine
Rough

25
20
20
100
20
20
30
30
32
21
21

0.95
0.95
0.98
0.94
0.93
0.90
0.90
0.96
0.98
0.90
0.93

Aluminium

Brass
Copper

WroughtIron

Lacquer

Carbon
Paint
Paper
Soil
Wood
Water
Skin
China
50

TI Series of Uncooled Focal Plane


Infrared Cameras
IRSee Report Software
User Manual

ZHEJIANG ULIRVISION TECHNOLOGY CO., LTD.

Table of Content

.SoftwareInstallation..................................................................1
1.Introduction...........................................................................1
2.SystemRequirements............................................................1
2.1HardwareConfiguration................................................1
2.2OperatingSystem..........................................................1
3.SoftwareInstallation.............................................................1
4.UninstallSoftware.................................................................3
5.StartSoftware........................................................................3
.FunctionDescription..................................................................4
1. ImageImportandExport..................................................4
1.1ImageImport................................................................4
1.2ImageExport.................................................................5
2.Modules...............................................................................6
2.1Ribbon...........................................................................6
2.2MeasuringTemperatureZone....................................14
2.3HistogramArea...........................................................21
2.4LineProfileMeasurementArea..................................24
2.5ColorCodeArea..........................................................25
2.6LabelArea...................................................................26
2.7VisibleLight.................................................................28

Disclaimer
1. Copyright
The copyright owner of this manual is Zhejiang ULIRvision Technology
Co.,Ltd.,Anycopying,editingandphotographingofthismanualinany
formisprohibitedwithoutapriorpermission.
2. Limited Liability
Software provided by ULIRvision Technology Co., Ltd. does not
guarantee the quality, performance or applicability of any hidden
specialpurpose.
Thecontentsofthismanualwillbeupdatedbecauseofdeviceupgrade
or other various reasons. Our company reserves the right to edit this
manualwithoutfurthernotice.
3. Quality Assurance
Thequalityadministrationsystemofthisproductduringtheprocessof
R&D and production has been approved in accordance with ISO9001
standard.
4. Compatibility with Previous Versions
This IRSee Software version supports all file and data created by any
IRSeeSoftwareversion.
5.CompatibilitywithInfraredCamera
This Software supports all JPEG format image recorded by TI Series
Infrared Camera, for device upgrade requirements, please contact
afterservicedepartmentofZhejiangUlirvisionTechnologyCo.,Ltd.

ii

. Software Installation
WelcometoUseIRSeesoftware.
1. Introduction
The IRSee Report version has a friendly user interface, 4 methods for
measureanalysis,andthefunctiontosaveanalysisreportinWord,PDF,
Excelandotherformats.
2.SystemRequirements
ThefilesoftheIRSeesoftwareconsistofIRimage,visualimageand
graphicfile,allofwhicharefarbiggerthannormaltextfiles,thusthe
followingstandardsofthecomputerhardwareconfigurationshouldbe
met:
2.1HardwareRequirements
CPUPENTIUMDualCore2.0GHzprocessororfaster.
1Gbytesormoresystemmemory.
20Gorbiggerharddisk.
1440900orhigherresolutionscreen.
2.2OperatingSystem
IRSeeSoftwareiscompatiblewithMicrosoftWindows2000,XP,Vista,
Windows7.Itprovidesamultilanguageversionforusers.
3.SoftwareInstallation
The instructions of IRSee software installation and necessary
precautions before using this software will be given in detail
hereinafter:
PleasefollowtheinstructionswheninstallingIRSeesoftwareapplication.
PlacesoftwareCDROMintoCDdrive,andrunsetup.exeintheCDroot
directory.
ThedefaultrouteisC:\ProgramFiles\ULIRvision\IRSeeReport.Youcan
changedirectorywheninstalling.

Note: The software to operating and install in administrator on the


Vista/Win7.
Step A: Running the Setup.exe, the system indicates the installation
path,pleaseadjustorchangeasneeded.

StepB:ClicktheNextbuttontoaccessthesoftwareinstallation.

StepC:ClicktheNextbuttoncontinuouslyuntilthesoftwareinstallation
is completed. The system will enter the decoder installation
automatically.

Step D: Click and follow the default installation settings until the
installationiscompleted.

4.UninstallSoftware
PleaseselecttheDeletebuttonifwanttoreinstallthesoftware.

5.StartingupSoftware
The following icon appears on Windows desktop after installing IRSee
software.

DoubleclicktheiconandstartupIRSeeinterface.

Openanimagebymenu:openoricon

intheribbon.

Note: IRSee software has 11 different working languages, namely:


Chinese (simplified & traditional), English, Italian, Japanese, Russian,
French, German, Korean, Spanish, Portuguese and polish. IRSee
software has autorecognition language function with the operating
systeminPC,theIRSeewillbeinEnglishversioniftheoperatingsystem
isbeyondmentionedlanguagesinPC.

.FunctionDescription
1.ImageImportandExport
1.1ImageImport
Method1:
4

Click the software icon on upper left corner to pop up the


menu.
Click the Open button (also available to select a recently
opened image path in the image bar) to pop up the file
selectiondialogbox.
Select a file in the file selection dialog box (single or multiple
selectionsavailable).
Method2:
ClicktheOpenbuttonintheribbon.

1.2ImageExport
Itisavailabletoexportinaccordancewiththefollowingmethodsafter
importingimages:
Method1:
Click the button Save Picture As button on the software
icon on the upper left corner to pop up a file selection dialog
box.
Select / a file path and save the image in the current active
window.
Method2:
Clickthepropertyanalysisintoolbar.
Click the button Save picture As button to pop up a file
selectiondialogbox.
Select / a file path and save the image in the current active
window.
Method3:
Clickthesoftwareicononthetopleftcorner.
Click the buttonSave current picture to save the modified
imageonthecurrentactivewindow.

Method4:
ClickthepropertyanalysisinRibbon.
5

Click the button Save current picture to save the modified


imageonthecurrentactivewindow.

2.Modules
Asdisplayedonthesoftwareinterface,thesoftwarehasthefollows:the
QuickAccessToolbar,Ribbon,MeasuringTemperatureZone,Histogram
Area,LineProfileMeasurementArea,ColorCodeArea,LabelArea,and
VisibleArea.

2.1Ribbon
The Ribbon is composed of File, Parameters, Voice, Temperature Type
Settings,ReportWizard,USB,PanelandLanguage.

2.1.1File
2.1.1.1Open

ClicktheFilebuttontopopupafileselectiondialogbox.
Selectandopenafiletobeanalyzedinthedialogbox.

2.1.1.2Save

Method1:

Click the Save current image button to pop up a file


selectiondialogbox.
Set/selectthefilepathnamewherethefileissaved.
Savetheimageinthecurrentactivewindow.
Method2:
ClicktheFileandselectthe Saveallimagesbuttonto
saveallthemodifiedimages.

2.1.2Set
2.1.2.1Emissivityadjustment

Method1:
Please input a required emissivity value (1100) in the
Emissivityeditbox.
PresstheEnterkeytoconfirmit.
Method2:
ClicktheUpandDownkeysintheeditboxtoadjustandset
anemissivityvalue.

2.1.2.2HumidityAdjustment
Please input a required humidity value (1100) in the humidity
editbox.
PresstheEnterkeytoconfirm.
2.1.2.3 DistanceAdjustment
Pleaseinputarequireddistancevalue(11000,unit:meter)inthe
distanceeditbox.
PresstheEnterkeytoconfirm.

2.1.2.4AmbientTemperature
Show ambient temperature value set in device setting when image is
taken.

2.1.2.5DewPointTemperature
Selecttheoptiontoshowthedewpointtemperature.

2.1.2.6CancelChanges
ClicktheReturntodefaultsettingsbuttontorecovertheemissivity,
humidity,ambienttemperature,ordistancetoitsoriginalstate.

2.1.3Audio
Whenanalysisthermalimageswithvoiceinformation,buttonsinaudio
sectionwouldbeeffectiveandshowingreen,youcanreplaythevoice
savedwiththeimagebyclickingcorrespondingbuttons.Otherwisethe
buttonswouldshowingrayandcannotbeoperated.

2.1.4SetTemperatureType
Thisoptionisusedtosetthetemperaturedisplayunit,click,orK
tosetthetemperatureunittoCelsius,FahrenheitorKelvinrespectively.

2.1.5ReportWizard
2.1.5.1ReportWizard
Report Wizard is used for creating a report, the Report Edit is mainly
usedforeditingareportforfurtheranalysis.
ClicktheReportWizardtoselectthetypeofexportedreportasneeded.

ClickNexttoselectanimageormultipleimages.

Fill in related information in accordance with different types of report


templates>>Preview

After necessary information completed, you can click thesavebutton


to save the report as needed. All reports have the same format of
.HXandrepotscanbeeditedagaininIRSeesoftware.

10

11

2.1.5.2EditReport
Ifareportistobeclosed,thesystemwillpromptwhethertosavethe
reportornot.

ClicktheOKbutton.

Inputandselectthesavingpathandfilename,andthenclicktheSave
button.
ClickthereportinRibbon>>EditReport

Selectasavedreporttoreopenandeditit.
12

2.1.6USBDirectTransmission
2.1.6.1Connection
ClicktheRibbonSettings>>USBDirectTrans

Connectadevice,settoUSBDirectTransmodeforthedevice.
ClickthedeviceirononPCsoftwareinterface>>Openthedevice>>
Play
2.1.6.2Video
Clickthedevice>>Record

Selectavideopath>>Inputthenameofthevideofile.

2.1.6.3Stopthevideo
ClickFile>>StopRecording
13

2.1.6.4Pause,StopandCloseDirecttrans
Click the Pause, Stop and Close buttons under the File menu
respectivelytostopthecurrentoperation.

2.1.6.5PrintScreen
ClickthePrintScreenbuttonandsavetheprintedimageintothePicture
folderundertheinstallationdirectory,andnameitbyatimeformat.

2.1.7Panel
It is mainly used for showing/ hiding each area, a user can adjust the
size and position of each display area as needed, and then click the
Save Settings to save the current settings, and click the Return to
defafultsettingstorecover.

2.2MeasuringTemperatureZone
Thefunctionaloptionsinmeasuringareaareshownbelow:
14

The measurement objectscan analyze the thermal images by the


followingthreekindsofanalysismethods:point,line,andarea.
Linemeasurementanalysishasfourtypes:arbitraryline,horizontal
line,verticallineandmultiplelineanalysis.
Area measurement analysis has below: rectangular, elliptical and
polygonalanalysis.
The system can analyze up to 20 spots objects, 10 lines analysis
object, 20 area analysis objects, 10 polygonal objects and 10
ellipticalobjectssimultaneously.

2.2.1SelectMeasuredObjects
Thepriorsequenceofobjectselectionispoint,line,andarea.
Whentwoormoreobjectsaresimultaneouslyselected,thesystem
canoperateinaccordancewiththeaboveprioritization.
e.g.: if both a point object and a line object are simultaneously
selected,thepointismorepriorthanline,thepointobjectwillbe
priorselected;
Ifbothanareaobjectandalineobjectaresimultaneouslyselected,
the line is more prior than the area; the line object will be prior
selected.

15

Iftwoormoreareasaresimultaneouslyselected,thesmallerarea
willprevail.
e.g.: If Rectangle 1 and Rectangle 2 are simultaneously selected,
Rectangle1issmallerthanRectangle2,Rectangle1willprevail.

2.2.2PointAnalysis
Createapoint

Clickthebutton
Movethemousetoapointtobeanalyzed,andclickit.

Moveapoint

Movethemousetoapointtobemoved.

When the mouse status changes to


thepoint.
Movethemouse.

, leftclick to select

Deleteapoint

Selectameasurementpointtobedeleted.

Clickthe
buttontodeleteselectedMeasuredObjects.

2.2.3LineAnalysis
Createaline

16

Arbitraryline

Clickthe

Createbuttontopopupamenu.

Clickthe

ArbitraryLinebutton.

Set a starting point of the line in the thermal image to be


analyzed.
Lefthold and drag the mouse to the terminal point of the
line.

VerticalLine

Clickthe

Createbuttontopopupamenu.

Clickthe VerticalLinebutton.
Settheverticalcoordinatesofstartingpointofthelinein
thethermalimagetobeanalyzed.
Lefthold and drag the mouse to the vertical coordinates
ofterminalpointoftheline.
HorizontalLine

Clickthe

Clickthe HorizontalLinebutton.
Setthehorizontalcoordinatesofstartingpointofthelinein
thethermalimagetobeanalyzed.
Leftholdanddragthemousetothehorizontalcoordinatesof
terminalpointoftheline.

Createbuttontopopupamenu.

Moveandchangealine

Move
Movethemousetothepositionofalinetobemoved.
,leftclicktoselectit.
Whenthestateofmousebecomes
Andthenmoveit.
Changethepositionsofstartingpoint/terminalpoint
Movethemousetothepositionofthelinetobemoved.

Whenthestateofmousebecomes
line.

,leftclicktoselectthe

17

Move the mouse to the position of starting point / terminal


pointtobemoved.

, leftclick to select
When the state of mouse becomes
startingpoint/terminalpoint.
Drag the mouse to the required position of starting point /
terminalpoint.

Deletealine

Selectthelinemeasurementobjecttobedeleted.

buttontodeleteselectedMeasuredObjects
Clickthe

2.2.4AreaAnalysis
Ithasthreeareas:rectangle,polygon,andellipse.
Createarectangle
Clickthe

CreateAreabuttontopopupamenu.

ClicktheRectangle .
Selectthestartingpointoftherectangleinthethermalimageto
be
analyzed.
Dragthemousetocreatearectangularanalysisarea.
MoveandDragaRectangle

Move
Movethemouseintotherectangletargetarea.

18

Whenthestateofmousebecomes
Movethemouse.

,clicktoselectit.

Zoomin/out
Movethemouseintotherectangletobemodified.

Whenthestateofmousebecomes ,clicktoselectit.
Movethemousetotheeightvertexesoftherectangle.

Whenthestateofmousebecomes ,clicktoselectit.
Movethemousetochangethesizeoftherectangle.

Deletearectangle
Selecttherectangleobjecttobedeleted.

buttontodeleteselectedMeasuredObjects
Clickthe
Createapolygon

Clickthe

ClickthePolygon .
Selectthestartingpointofthepolygoninthethermalimageto
beanalyzed.
Movethemouseandleftclicktoaddotherverticesofpolygon.
Rightclicktostopaddingthevertexestocreateapolygon.
If the number of vertexes is equal to or more than 50, the
systemcanstopaddingautomatically.

CreatePolygontopopupamenu.

MoveandDragaPolygon

Move
Movethemouseintothepolygontobeanalyzed.
Whenthestateofmousebecomes ,clicktoselectit.
Movethemouse.
Zoomin/out
Movethemouseintothepolygontobemodified.
19

Whenthestateofmousebecomes ,clicktoselectit.
Movethemousetoavertextobemodified.

Whenthestateofmousebecomes ,clicktoselectit.
Movethemousetochangethepositionofthevertex,thusto
modifythepolygon.

DeleteaPolygon

Selectthepolygontobedeleted.

Clickthe

buttontodeleteselectedMeasuredObjects

Addanellipse

Clickthe

ClicktheEllipse .
Selectthestartingpointoftheellipseinthethermalimageto
beanalyzed.
Dragthemousetocreateanellipticalanalysisarea.

AddAreabuttontopopupamenu.

MoveandDraganEllipse

20

Move
Movethemouseintotheellipsetobemoved.
Whenthestateofmousebecomes ,clicktoselectit.
Movethemouse.
Zoomin/out
Movethemouseintotheellipsetobemodified.

Whenthestateofmousebecomes ,clicktoselectit.
Movethemousetotheeightvertexes.

Whenthestateofmousebecomes

,clicktoselectit.

Movethemousetochangethesizeoftheellipse.

Deleteanellipse

Selecttheellipsetobedeleted.

Clickthe

2.2.5SaveImages
Clickthe
box.

buttontodeleteselectedMeasuredObjects

SaveImagesbuttontopopupthefileselectiondialog

Selectimageformats

Select/setthefilepath.
ClicktheSavebuttontosavetheimage.

2.2.6Clearmeasuredobjects
Clickthe ClearMeasuredObjectsbuttontoclearallpoint,line,area
analysisofmeasuredtargets.

2.2.7PIP/Infrared
Clickthe
buttontoswitchbetweenthePIPandinfraredmodes.

2.2.8ExportTemperatureData
Clickthe
buttontoexportallthepointstemperatureinthewhole
thermalimagetoTXTfile,thetemperatureunitisCelsius.

2.3HistogramArea
21

2.3.1Relative/absoluteScale
If the relative scale is selected, the vertical axis represents the
percentage of the number of measured points; if the absolute scale is
selected, the vertical axis represents the actual number of
correspondingmeasuredpoints.Itisavailabletoclickthe
switch.

2.3.2Gradient/SolidColorDisplay

buttonto

If the gradient histogram display mode is enabled, the system can


automatically select corresponding color to fill the histogram in
accordance with the temperature; If the solid color display mode is
enabled,thesystemwillfillhistogramwithred.itisavailabletoclickthe
buttontoswitch.

2.3.3Enable/DisenableGrid
If the grid is enabled, it is available to draw grid dashed lines on the
histogram background; if disenabled, its unavailable to draw. it is
availabletoclickthe

22

buttontoswitch.

2.3.4SaveaHistogram

Clickthe
SaveImagesbuttontopopupthefileselectiondialog
box.
Selecttheimageformat.
Check/setthepathtosavetheimage.
ClicktheSavebuttontosavethecurrenthistogram.

2.3.5SettheBackgroundColor

Click the
Set Background Color button to popup color
selectiondialogbox.
Selectabackgroundcolor.
ClicktheOKbuttontoconfirmthebackgroundcolor.

2.3.6Show/HidetheOutofRangeColumn
Click the
button to show or hide any column out of temperature
rangeofcolorcodebar,composedofpoints.

2.3.7Reset
Clickthe

Resetbuttontoreloadthedefaultstatetothehistogram.

23

2.4LineProfileMeasurementArea

2.4.1Show/hidegridlines
Clickthe
Gridbuttontoswitchthegriddisplayandhidemode.

2.4.2Setthebackgroundcolor

Click the
background color button to popup color selection
dialogbox.
Selectabackgroundcolor.
ClicktheOKbuttontoconfirmthebackgroundcolor.

2.4.3Savethelineprofilemeasurementimage

24

Clickthe
buttontopopupthefileselectiondialogbox.
Selectanimageformat.
Check/setthepathtosavetheimage.
ClicktheSavebuttontosavethelineprofilemeasurementimage.

2.5ColorCodeArea

Itisavailabletoadjustthetypeofcolorcode,12kindsofcolorbarsare
available. A User can also adjust the maximum or minimum
temperature, and isothermal upper and lower limits, any outofrange
temperature can not be supported. If the dew point is selected, the
corresponding color code of below the dew point temperature will be
unified.

2.5.1Defaultmaximumorminimumtemperatureandupperand
lowerlimitsofisothermalcolor
Clickthe
buttontoreloaddefaultsettings.

2.5.2Adjustupperandlowertemperature

Method1:
Movethemouseto
theupperandlowertemperature
onleftsideofthecolorbar;

, please leftclick to
When the mouses status turns
select;
Dragthemousetotherequiredtemperaturevalueposition.
Method2:
25

Click the scroll bar on the arrow button to adjust upperand


lowertemperature(eachstepis0.1)
2.5.3Adjustupperandlowerlimitsofisothermalcolor,
Iftheisothermalcolorisenabled,ausercanadjusttheisothermalscope
Method1:
theupperandlowertemperature
Movethemouseto
onrightsideofthecolorbar.

Whenthemousesstatusturns ,pleaseleftclicktoselect.
Dragthemousetotherequiredtemperaturevalueposition.

Method2:
Click the scroll bar on the arrow button to adjust upperand
lowerlimits(eachstepis0.1).

2.5.4Selectadewpoint
Whenadewpointisselected,allpointswhichtemperatureisbelowthe
dewpointwillbecoloredinuniform.

2.5.5Setisothermalcoloranddewpointcolor
Thedefaultisothermalcolorisfluorescentgreen,thedefaultdewpoint
colorisblue,andthedewpointispriorselected.
Set Color button, to pop up the color selection
Click the
dialogbox.
Select/customizethebackgroundcolor.
ClicktheOKbuttontoconfirmtheselectedcolor.

2.6LabelArea
The Label Area indicates detailed information of measured objects,
when the measured object changes, the object's label will change
accordingly,thestructureoflabelareaisasbelow:
26

2.6.1Setthecolorofmeasuredobject

Selectameasuredobjectinthelabellist.

Clickthe
buttontosetacolorforcurrentlyselectedobject.

Select/customizeacolor.

ClicktheOKbuttontoconformthecolorofmeasuredobject.

2.6.2Addremarksformeasuredobject

Selectameasuredobjectinthelabellist.
AddRemarksintheRemarkseditbox(0512charactersavailable).

Clickthe
UploadCurrentSettingsbuttontoaddremarks.
2.6.3Changeemissivityofmeasuredobject

Selectameasuredobjectinthelabellist.
Adjustthescrollbarofemissivity.

2.6.4Removeameasuredobject

Selectameasuredobjectinthelabellist.

Clickthe

buttontodeletethecurrentlyselectedobject.

27

2.6.5AdddetailedInformationinImageremarks
If any object in the label is not selected, it is available to input
information.

2.7VisibleLight

2.7.1OpenanImage
Clickthe
Openbuttontopopupthefileselectiondialogbox.
Selectafiletobeaddedfromthedialogbox.

2.7.2Saveanimage

28

Clickthe
Savebuttontopopupthefileselectiondialogbox.
Selectanimageformat.

Check/setthepathwheretheimageissaved.

Savethevisiblelightimage.
2.7.3Deleteanimage

Clickthe
Deletebuttontodeletethecurrentlyaddedvisibleimage.

2.7.4Flipanimage
Thisfeatureisavailableforanyimagethatwithoutvisiblelight.
Click the
or
counterclockwise.

button to flip an image clockwise or

2.7.5PIP
Thisfeatureisavailableforanyimagethatwithvisiblelight.
Clickthe

buttontosetanimage.

29

Setthetransparency
Drag the lower left progress bar to adjust the PIP values between
infraredimageandvisibleimage.

Setinfrareddisplayrange
Dragtherighttwoprogressbarstoadjusttheinfrareddisplayrangeof
intervaloraboveupperorbelowlowerlimit.

ClicktheOKbuttontosavethefile,theupdatedimageisdisplayedon
themeasurementarea.

30

ZHEJIANG ULIRVISION TECHNOLOGY CO., LTD



Address: 2nd floor Building D, the Westlake International Plaza
#391 Wener Road, Hangzhou, Zhejiang Province, China
TEL: +86571 8720 9879

FAX:
+865718512 5358
Email: overseas@ulirvision.com