You are on page 1of 456

Section 1: Grilles & Diffusers

clever. creative. comfort.

www.titus-hvac.com | www.titus-energysolutions.com

www.titus-hvac.com | www.titus-energysolutions.com

Table of Contents

AeroBlade Grilles

aeroblade grilles
AeroBlade Grille Products...............................................................................................................................................................G4

overview
Overview.........................................................................................................................................................................................G6

aeroblade supply grilles


AeroBlade Supply Grilles................................................................................................................................................................G7
3
/4-inch Spacing - Steel...........................................................................................................................................................G7
271 (RL/RS) - Single Deflection..............................................................................................................................................G7
272 (RL/RS) - Double Deflection.............................................................................................................................................G7
/4-inch Spacing - Aluminum...................................................................................................................................................G8
271 (FL/FS) - Single Deflection...............................................................................................................................................G8
272 (FL/FS) - Double Deflection..............................................................................................................................................G8

11/4-inch Spacing - Steel.........................................................................................................................................................G9


111 (RL/RS) - Single Deflection..............................................................................................................................................G9
112 (RL/RS) - Double Deflection.............................................................................................................................................G9
2-inch Spacing - Steel...........................................................................................................................................................G10
121 (RL/RS) - Single Deflection............................................................................................................................................G10
122 (RL/RS) - Double Deflection...........................................................................................................................................G10
3-inch Spacing - Steel...........................................................................................................................................................G11
131 (RL/RS) - Single Deflection............................................................................................................................................G11
132 (RL/RS) - Double Deflection...........................................................................................................................................G11
Performance Data.................................................................................................................................................................G12
Performance Notes...............................................................................................................................................................G17
Horizontal Deflection (Spread)..............................................................................................................................................G18
Suggested Specifications......................................................................................................................................................G19
Model Number Specification................................................................................................................................................G19

aeroblade return grilles


AeroBlade Return Grilles..............................................................................................................................................................G21
3
/4-inch Spacing - Steel.........................................................................................................................................................G21
23 (RL/RS) - 45B Deflection...................................................................................................................................................G21
/4-inch Spacing - Aluminum.................................................................................................................................................G22
3 (FL/FS) - 45B Deflection......................................................................................................................................................G22
56 (FL/FS) - 0B Deflection......................................................................................................................................................G22

AEROBLADE GRILLES

G2

/2-inch Spacing - Steel.........................................................................................................................................................G23


25 (RL/RS) - 30B Deflection...................................................................................................................................................G23

/2-inch Spacing - Aluminum.................................................................................................................................................G24


4 (FL/FS) - 45B Deflection......................................................................................................................................................G24
55 (FL/FS) - 0B Deflection......................................................................................................................................................G24

Narrow Tee Return Grilles.....................................................................................................................................................G25


Filter Return Grilles...............................................................................................................................................................G26
Performance Data.................................................................................................................................................................G27
23R - -inch - 45B Deflection...............................................................................................................................................G27
25R - -inch - 30B Deflection...............................................................................................................................................G29
3F, 4F - 45B Deflection...........................................................................................................................................................G31
55F, 56F - 0B Deflection.........................................................................................................................................................G33

Table of Contents (continued)

AeroBlade Grilles

options & accessories


Options & Accessories..................................................................................................................................................................G37
Border Types.........................................................................................................................................................................G38
Accessories...........................................................................................................................................................................G38
Oversize Grille Construction..................................................................................................................................................G39
Screw Hole Location Chart...................................................................................................................................................G40
Common Size Chart...............................................................................................................................................................G41

www.titus-hvac.com | www.titus-energysolutions.com

Suggested Specifications......................................................................................................................................................G35
Model Number Specification................................................................................................................................................G35

AEROBLADE GRILLES
G3

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

AeroBlade Grille Products

AEROBLADE GRILLES

G4

AEROBLADE SUPPLY GRILLES

pages: G8-G26

271, 272 (RL, RS)

271, 272 (FL, FS)

111, 112 (RL, RS)

121, 122 (RL, RS)

SINGLE & DOUBLE


DEFLECTION GRILLES

SINGLE & DOUBLE


DEFLECTION GRILLES

SINGLE & DOUBLE


DEFLECTION GRILLES

SINGLE & DOUBLE


DEFLECTION GRILLES

Individually adjustable airfoil blades.


Blades parallel to the long
or short dimension.
20-gauge steel border,
extruded aluminum blades.
Standard finish is #26 white.

Individually adjustable airfoil blades.


Blades parallel to the long
or short dimension.
Extruded aluminum border & blades.
Standard finish is #26 white.

Individually adjustable airfoil blades.


Blades parallel to the
long dimension.
20-gauge steel border,
extruded aluminum blades.
Standard finish is #26 white.

Individually adjustable airfoil blades.


Blades parallel to the long
or short dimension.
20-gauge steel border,
extruded aluminum blades.
Standard finish is #26 white.

131, 132 (RL, RS)


SINGLE & DOUBLE
DEFLECTION GRILLES
Individually adjustable airfoil blades.
Blades parallel to the
long dimension.
20-gauge steel border,
extruded aluminum blades.
Standard finish is #26 white.

AeroBlade Grilles

AeroBlade Grille Products (continued)

23 (RL, RS)

3 (FL, FS)

56 (FL, FS)

25 (RL, RS)

FIXED DEFLECTION
GRILLES

FIXED DEFLECTION
GRILLES

FIXED DEFLECTION
GRILLES

FIXED DEFLECTION
GRILLES

45B fixed deflection.


Steel grille with 3/4-inch
blade spacing.
Blades parallel to the long
or short dimension.
20-gauge steel border.
Standard finish is #26 white.

45B fixed deflection.


Aluminum grille with 3/4inch blade spacing.
Front blades parallel to the
long or short dimension.
Extruded aluminum border & blades.
MRI compatible.
Standard finish is #26 white.

0B fixed deflection.
Aluminum grille with 3/4inch blade spacing.
Front blades parallel to the
long or short dimension.
Extruded aluminum border & blades.
MRI compatible.
Standard finish is #26 white.

30B fixed deflection.


Steel grille with 1/2-inch
blade spacing.
Blades parallel to the long
or short dimension.
20-gauge steel border & blades.
Standard finish is #26 white.

55 (FL, FS)

FIXED DEFLECTION
GRILLES

FIXED DEFLECTION
GRILLES

45B fixed deflection.


Aluminum grille with 1/2inch blade spacing.
Front blades parallel to
the long dimension.
Extruded aluminum border & blades.
MRI compatible.
Standard finish is #26 white.

0B fixed deflection.
Aluminum grille with 1/2inch blade spacing.
Front blades parallel to
the long dimension.
Extruded aluminum border & blades.
MRI compatible.
Standard finish is #26 white.

AEROBLADE GRILLES

4 (FL, FS)

www.titus-hvac.com | www.titus-energysolutions.com

AEROBLADE RETURN GRILLES

pages: G49-G69

G5

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

Overview

Titus AeroBlade grilles are the industry standard for high


performance and high quality. The unique airfoil blade
design provides maximum performance with a reduction in
pressure drop and noise. With extruded aluminum construction, pleasing aesthetics and superior performance, Titus
AeroBlade grilles are the ultimate choice for engineers and
architects looking to maximize performance, looks, and
functionality.
AeroBlade supply grilles feature heavy gauge frames and
solid aluminum blades to accommodate any commercial
or industrial application. They are available in single or
double deflection and four different blade spacing widths.
AeroBlade return grilles also feature heavy gauge frame
and blade construction and are available in or blade
spacing with 0 degree or 45 degree deflection.The return
grilles also include an option for a factory installed filter rack
to accommodate 1 or 2 thick filters. Optional opposed
blade dampers are available in steel or aluminum material,
and are factory installed.

Return

AEROBLADE GRILLES

Available
Material
Types
A
S
SA

Steel Border

Description

Function

Supply

G6

The quietest grilles in the industry.


Available in steel or aluminum.
Supply grilles available in four different blade spacing options.
Return grilles available in two blade spacing options
Supply grille blades are solid aluminum with an airfoil cross-section.
Borders formed of 20-gauge steel or
heavy gauge, extruded aluminum.
Available with concealed or standard fastening method.
Screw holes in the border are countersunk for smooth appearance.
Available in several paint finish options including anodized colors.

Deflection
Single
Double
Single
Double
Single
Double
Single
Double
45 Fixed
0 Fixed
30 Fixed
45 Fixed
0 Fixed

Long Front
Blades
271RL
272RL
111RL
112RL
121RL
122RL
131RL
132RL
23RL

25RL

Blade Spacing

1
1
2
2
3
3

Aluminum Border

Short Front
Blades
271RS
272RS
111RS
112RS
121RS
122RS
131RS
132RS
23RS

25RS

Long Front
Blades
271FL
272FL

3FL
56FL

4FL
55FL

Short Front
Blades
271FS
272FS

3FS
56FS

4FS
55FS

Model
Supply

Return

271 272 111 112 121 122 131 132

23

56

25

55

23F 25F

3F

4F

55F 56F

Note: A = Aluminum Border and Blades, S = Steel, SA = Steel Border with Aluminum Blades or Core. Some aluminum models
may be constructed of all nonmagnetic components (no plastics) to meet MRI requirements. Consult your Titus representative
for specific details. See individual model information for construction details. Titus reserves the right to make product
improvements on a continual basis. As products are updated, new submittal sheets are published. Your Titus representative can
provide you with updated technical information on all products.

AeroBlade Grilles

Available Single Deflection Models:


271RL
271RS
Available Double Deflection Models:
272RL
272RS
Products Include:
Material: Steel Border with
Extruded Aluminum Blades.
Welded Border.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch Long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel-Opposed
Blade Damper.

271RS
-inch blade spacing.
Single deflection.
Individually adjustable
airfoil blades.
Blades parallel to the
short dimension.
20-gauge border.

272RS
-inch blade spacing.
Double deflection.
Individually adjustable
airfoil blades.
Front blades parallel to the
short dimension.
20-gauge border.

271RL
Same as 271RS with blades
parallel to the long dimension.

272RL
Same as 272RS with front blades
parallel to the long dimension.

Single Deflection Models: 271RL/271RS - Border Type 1


D plus 1"

For Performance Data, refer to page G12.


For Suggested Specifications, refer to page
G19.

272 (RL, RS)

271 (RL, RS)

-INCH SPACING - STEEL

1"
9/16"

www.titus-hvac.com | www.titus-energysolutions.com

AeroBlade Supply Grilles


271, 272 (RL, RS)

D minus "
"

"

Optional
Opposed
Blade
Damper

1"

2"

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
Double Deflection Models: 272RL/272RS - Border Type 1
D plus 1"
1"
9/16"

D minus "
"

113/16"
39/16"

Optional
Opposed
Blade
Damper
D minus "

271, 272 (RL, RS)

"

Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

G7

AeroBlade Grilles

271, 272 (FL, FS)


Available Single Deflection Models:
271FL
271FS
Available Double Deflection Models:
272FL
272FS
Products Include:
Material: Heavy
Extruded Aluminum.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch Long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel or Aluminum OpposedBlade Damper.
For Performance Data, refer to page G12.
For Suggested Specifications, refer to page
G20.

272 (FL, FS)

-INCH SPACING - ALUMINUM


271 (FL, FS)

www.titus-hvac.com | www.titus-energysolutions.com

AeroBlade Supply Grilles (continued)

271FS
-inch blade spacing.
Single deflection.
Individually adjustable
airfoil blades.
Blades parallel to the
short dimension.
Extruded aluminum border.

272FS
-inch blade spacing.
Double deflection.
Individually adjustable
airfoil blades.
Front blades parallel to the
short dimension.
Extruded aluminum border.

271FL
Same as 271FS with Blades
Parallel to the Long Dimension.

272FL
Same as 272FS with front blades
parallel to the long dimension.

Single Deflection Models: 271FL/271FS - Border Type 1


D plus 1"
1"
9/16"

D minus "
"

3/16"

Optional
Opposed
Blade
Damper

1"

2"

D minus "
Nominal Duct
" Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
Double Deflection Models: 272FL/272FS - Border Type 1
D plus 1"

271, 272 (FL, FS)

1"
9/16"

D minus "
"

3/16"

111/16"
37/16"

Optional
Opposed
Blade
Damper
D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.

G8

All dimensions are in inches.

AeroBlade Grilles

AeroBlade Supply Grilles (continued)

1-INCH SPACING - STEEL

Available Double Deflection Models:


112RL
112RS
Products Include:
Material: Steel Border with
Extruded Aluminum Blades.
Welded Border.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch Long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel-Opposed Blade Damper.

111RS
1-inch blade spacing.
Single deflection.
Individually adjustable
airfoil blades.
Blades parallel to the
short dimension.
20-gauge border.

112RS
1-inch blade spacing.
Double deflection.
Individually adjustable
airfoil blades.
Front blades parallel to the
short dimension.
20-gauge border.

111RL
Same as 111RS with blades
parallel to the long dimension.

112RL
Same as 112RS with front blades
parallel to the long dimension.

Single Deflection Models: 111RL/111RS - Border Type 1


D plus 1"

For Performance Data, refer to page G12.


For Suggested Specifications, refer to page
G19.

112 (RL, RS)

111 (RL, RS)

Available Single Deflection Models:


111RL
111RS

1"

D minus "
1"

9/16"

www.titus-hvac.com | www.titus-energysolutions.com

111, 112 (RL, RS)

"

Optional
Opposed
Blade
Damper

1"

3"

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
Double Deflection Models: 112RL/112RS - Border Type 1
D plus 1"
1"
9/16"

D minus "
1"

"

47/16"

Optional
Opposed
Blade
Damper
D minus "

111, 112 (RL, RS)

211/16"

Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

G9

AeroBlade Grilles

121, 122 (RL, RS)


Available Single Deflection Models:
121RL
121RS
Available Double Deflection Models:
122RL
122RS
Products Include:
Material: Steel Border with
Extruded Aluminum Blades.
Welded Border.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch Long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel-Opposed Blade Damper.

121RS
2-inch blade spacing.
Single deflection.
Individually adjustable
airfoil blades.
Blades parallel to the
short dimension.
20-gauge border.

122RS
2-inch blade spacing.
Double deflection.
Individually adjustable
airfoil blades.
Front blades parallel to the
short dimension.
20-gauge border.

121RL
Same as 121RS with blades
parallel to the long dimension.

122RL
Same as 122RS with front blades
parallel to the long dimension.

Single Deflection Models: 121RL/121RS - Border Type 1

For Performance Data, refer to page G12.


For Suggested Specifications, refer to page
G19.

122 (RL, RS)

2-INCH SPACING - STEEL


121 (RL, RS)

www.titus-hvac.com | www.titus-energysolutions.com

AeroBlade Supply Grilles (continued)

D plus 1"
1"

9/16"

D minus "
2"

"

Optional
Opposed
Blade
Damper

2"

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
Double Deflection Models: 122RL/122RS - Border Type 1
D plus 1"

121, 122 (RL, RS)

9/16"

1"

D minus
" "
2"

"

4"
6"

Optional
Opposed
Blade
Damper
D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.

G10

All dimensions are in inches.

4"

AeroBlade Grilles

AeroBlade Supply Grilles (continued)

3-INCH SPACING - STEEL

Available Double Deflection Models:


132RL
132RS
Products Include:
Material: Steel Border with
Extruded Aluminum Blades.
Welded Border.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch Long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel-Opposed Blade Damper.
For Performance Data, refer to page G12.
For Suggested Specifications, refer to page
G19.

132 (RL, RS)

131 (RL, RS)

Available Single Deflection Models:


131RL
131RS

131RS
3-inch blade spacing.
Single deflection.
Individually adjustable
airfoil blades.
Blades parallel to the
short dimension.
20-gauge border.

132RS
3-inch blade spacing.
Double deflection.
Individually adjustable
airfoil blades.
Front blades parallel to the
short dimension.
20-gauge border.

131RL
Same as 131RS with blades
parallel to the long dimension.

132RL
Same as 132RS with front blades
parallel to the long dimension.

Single Deflection Models: 131RL/131RS - Border Type 1



D plus 1"
9/16"

D minus "

1"

3"

www.titus-hvac.com | www.titus-energysolutions.com

131, 132 (RL, RS)

"

3"
Optional
Opposed
Blade
Damper

5"

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
Double Deflection Models: 132RL/132RS - Border Type 1
9/16"

D plus 1"
D minus "

1"
3"

"

8"
Optional
Opposed
Blade
Damper
D minus "
Nominal Duct Size D"

131, 132 (RL, RS)

6"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

G11

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

G12

PERFORMANCE DATA

AeroBlade Grilles

MODELS: 271, 272, 111, 112, 121, 122, 131 AND 132
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

NC 20

Core Vel.
300
Nom. Nom.
Core Vel. Press.
0.006
Duct Duct
Area
0
0.010
Size Area
(ft2) Total 22.5 0.011
(in.) (ft2)
Press. 45
0.016
cfm
57
NC
6x6 0.25 0.19
0
5-7-14
Throw 22.5
4-6-11
(ft)
45
2-3-6
cfm
78
NC
8x6 0.33 0.26
0
5-9-16
Throw 22.5
4-7-13
(ft)
45
2-4-7
cfm
102
NC
10x6 0.42 0.34
0
6-10-19
Throw 22.5
5-8-14
(ft)
45
3-4-8
cfm
111
NC
8x8 0.44 0.37
0
6-10-19
Throw 22.5
5-8-15
(ft)
45
3-5-9
cfm
123
NC
12x6 0.50 0.41
0
7-11-20
Throw 22.5
5-8-16
(ft)
45
3-5-9
cfm
144
NC
14x6 0.58 0.48
0
7-12-22
Throw 22.5
6-9-17
(ft)
45
3-5-10
cfm
171
16x6
NC
12x8 0.67 0.57
0
8-13-24
Throw 22.5 6-10-19
(ft)
45
4-6-11
cfm
177
NC
10x10 0.69 0.59
0
8-13-24
Throw 22.5 6-10-19
(ft)
45
4-6-11
cfm
189
NC
18x6 0.75 0.63
0
8-13-25
Throw 22.5 6-10-20
(ft)
45
4-6-11
cfm
216
20x6
NC
12x10 0.83 0.72
0
9-14-27
Throw 22.5 7-11-21
(ft)
45
4-6-12
cfm
231
NC
22x6 0.92 0.77
0
9-15-28
Throw 22.5 7-12-22
(ft)
45
4-7-13
cfm
264
24x6
NC
18x8 1.00 0.88
0
10-16-30
12x12
Throw 22.5 8-12-23
(ft)
45
4-7-13
cfm
333
30x6
NC
18x10 1.25 1.11
0
11-18-34
Throw 22.5 9-14-26
(ft)
45
5-8-15

400
0.010
0.017
0.019
0.029
76
7-10-16
5-8-12
3-4-7
104
8-12-19
6-9-15
3-5-8
136
9-13-21
7-10-17
4-6-10
148
9-14-22
7-11-17
4-6-10
164
10-15-24
7-11-18
4-7-11
192
10-16-25
8-12-20
5-7-11
228
11-17-28
9-13-22
5-8-12
236
12-17-28
9-13-22
5-8-13
252
12-18-29
9-14-23
5-8-13
288
13-19-31
10-15-24
6-9-14
308
13-20-32
10-15-25
6-9-15
352
14-21-34
11-16-27
6-10-16
444
16-24-39
12-18-30
7-11-17

500
0.016
0.027
0.030
0.045
95
8-12-18
6-10-14
4-6-8
130
10-14-21
7-11-16
4-6-9
170
11-17-24
9-13-19
5-7-11
185
11-17-25
9-13-19
5-8-11
205
12-18-26
9-14-20
5-8-12
240
13-20-28
10-15-22
6-9-13
285
14-21-31
11-17-24
6-10-14
295
14-22-32
11-17-24
7-10-14
315
15-22-33
12-17-25
7-10-15
360
11
16-24-35
12-19-27
7-11-16
385
11
17-25-36
13-19-28
7-11-16
440
11
18-27-39
14-21-30
8-12-17
555
12
20-30-43
15-23-34
9-13-19

600
0.022
0.038
0.043
0.065
114
11
10-14-20
8-11-15
4-6-9
156
12
12-16-23
9-13-18
5-7-10
204
13
13-19-26
10-14-20
6-8-12
222
13
14-19-27
11-15-21
6-9-12
246
14
15-20-29
11-16-22
7-9-13
288
14
16-22-31
12-17-24
7-10-14
342
15
17-24-34
13-19-26
8-11-15
354
15
17-24-35
13-19-27
8-11-16
378
16
18-25-36
14-20-28
8-11-16
432
16
19-27-38
15-21-30
9-12-17
462
16
20-28-40
15-22-31
9-13-18
528
17
21-30-42
16-23-33
10-13-19
666
18
24-34-47
18-26-37
11-15-21

700
0.031
0.052
0.058
0.089
133
15
12-15-21
9-12-16
5-7-10
182
16
13-18-25
10-14-19
6-8-11
238
18
15-20-28
12-16-22
7-9-13
259
18
16-21-30
12-16-23
7-9-13
287
18
17-22-31
13-17-24
8-10-14
336
19
18-24-34
14-18-26
8-11-15
399
20
20-26-37
15-20-28
9-12-17
413
20
20-26-37
16-20-29
9-12-17
441
20
21-27-39
16-21-30
9-12-17
504
21
22-29-41
17-23-32
10-13-19
539
21
23-30-43
18-23-33
10-14-19
616
22
25-32-46
19-25-35
11-15-21
777
23
28-36-51
22-28-40
13-16-23

800
0.040
0.068
0.076
0.116
152
19
13-16-23
10-12-18
6-7-10
208
20
15-19-27
12-15-21
7-8-12
272
22
18-21-30
14-17-23
8-10-14
296
22
18-22-32
14-17-25
8-10-14
328
22
19-24-33
15-18-26
9-11-15
384
23
21-25-36
16-20-28
9-11-16
456
24
23-28-39
18-22-30
10-12-18
472
24
23-28-40
18-22-31
10-13-18
504
24
24-29-41
18-23-32
11-13-19
576
25
25-31-44
20-24-34
11-14-20
616
25
26-32-46
20-25-35
12-15-21
704
26
28-34-49
22-27-38
13-16-22
888
27
32-39-55
25-30-42
14-17-25

NC 30
1000
0.062
0.106
0.118
0.181
190
26
15-18-25
11-14-20
7-8-11
260
27
17-21-30
13-16-23
8-9-13
340
28
20-24-34
15-19-26
9-11-15
370
29
20-25-35
16-19-27
9-11-16
410
29
21-26-37
17-20-29
10-12-17
480
30
23-28-40
18-22-31
10-13-18
570
30
25-31-44
20-24-34
11-14-20
590
31
26-32-45
20-24-35
12-14-20
630
31
27-33-46
21-25-36
12-15-21
720
31
28-35-49
22-27-38
13-16-22
770
32
29-36-51
23-28-40
13-16-23
880
32
31-39-55
24-30-42
14-17-25
1110
33
35-43-61
27-34-47
16-19-28

Performance notes appear at end of table.


See the table, Correction Factors for Various Models on page G17 to determine appropriate factor.

NC 40
1200
0.090
0.153
0.171
0.260
228
31
16-20-28
12-15-22
7-9-12
312
33
19-23-32
15-18-25
8-10-15
408
34
21-26-37
17-20-29
10-12-17
444
34
22-27-39
17-21-30
10-12-17
492
34
24-29-41
18-22-32
11-13-18
576
35
25-31-44
20-24-34
11-14-20
684
36
28-34-48
22-26-37
12-15-22
708
36
28-35-49
22-27-38
13-16-22
756
36
29-36-51
23-28-39
13-16-23
864
37
31-38-54
24-30-42
14-17-24
924
37
32-40-56
25-31-43
15-18-25
1056
38
34-42-60
27-33-46
16-19-27
1332
39
39-47-67
30-37-52
17-21-30

1400
0.122
0.208
0.232
0.354
266
36
17-21-30
13-16-23
8-10-13
364
37
20-25-35
16-19-27
9-11-16
476
38
23-28-40
18-22-31
10-13-18
518
39
24-30-42
19-23-32
11-13-19
574
39
25-31-44
20-24-34
11-14-20
672
40
28-34-48
21-26-37
12-15-21
798
40
30-37-52
23-28-40
13-17-23
826
41
31-37-53
24-29-41
14-17-24
882
41
32-39-55
24-30-42
14-17-25
1008
41
34-41-58
26-32-45
15-19-26
1078
42
35-43-60
27-33-47
16-19-27
1232
42
37-46-65
29-35-50
17-21-29
1554
43
42-51-72
32-40-56
19-23-33

AeroBlade Grilles

PERFORMANCE DATA

300
0.006
0.010
0.011
0.016
366
12-19-35
9-15-27
5-8-16
405
12-20-37
9-15-29
5-9-17
411
12-20-37
9-15-29
6-9-17
447
13-21-39
10-16-30
6-9-17
477
13-21-40
10-17-31
6-10-18
486
13-22-41
10-17-31
6-10-18
546
14-23-43
11-18-33
6-10-19
621
15-24-46
12-19-36
7-11-21
642
15-25-47
12-19-36
7-11-21
687
16-26-48
12-20-37
7-12-22
738
16-27-50
13-21-39
7-12-22
771
17-27-51
13-21-40
8-12-23
825
17-28-53
13-22-41
8-13-24

400
0.010
0.017
0.019
0.029
488
17-25-41
13-19-31
8-11-18
540
18-26-43
14-20-33
8-12-19
548
18-27-43
14-21-33
8-12-19
596
18-28-45
14-21-35
8-12-20
636
19-29-46
15-22-36
9-13-21
648
19-29-47
15-22-36
9-13-21
728
20-31-50
16-24-38
9-14-22
828
22-33-53
17-25-41
10-15-24
856
22-33-54
17-26-42
10-15-24
916
23-34-56
18-27-43
10-15-25
984
24-36-58
18-28-45
11-16-26
1028
24-36-59
19-28-46
11-16-27
1100
25-38-61
19-29-47
11-17-27

500
0.016
0.027
0.030
0.045
610
13
21-31-45
16-24-35
9-14-20
675
13
22-33-48
17-25-37
10-15-21
685
13
22-33-48
17-26-37
10-15-22
745
14
23-35-50
18-27-39
10-16-23
795
14
24-36-52
18-28-40
11-16-23
810
14
24-36-52
19-28-41
11-16-24
910
15
25-38-55
20-30-43
11-17-25
1035
15
27-41-59
21-32-46
12-18-27
1070
15
28-41-60
21-32-47
12-19-27
1145
15
29-43-62
22-33-48
13-19-28
1230
16
30-44-64
23-34-50
13-20-29
1285
16
30-45-66
23-35-51
14-20-30
1375
16
31-47-68
24-36-53
14-21-31

600
0.022
0.038
0.043
0.065
732
18
25-35-50
19-27-39
11-16-22
810
19
26-37-52
20-29-41
12-17-24
822
19
27-37-53
21-29-41
12-17-24
894
19
28-39-55
21-30-43
12-17-25
954
19
29-40-57
22-31-44
13-18-26
972
19
29-41-57
22-31-44
13-18-26
1092
20
31-43-61
24-33-47
14-19-27
1242
21
33-46-65
25-36-50
15-21-29
1284
21
33-47-66
26-36-51
15-21-30
1374
21
34-48-68
27-37-53
15-22-31
1476
21
36-50-71
28-39-55
16-22-32
1542
21
36-51-72
28-40-56
16-23-32
1650
22
38-53-75
29-41-58
17-24-34

NC 30
700
0.031
0.052
0.058
0.089
854
23
29-38-54
23-29-42
13-17-24
945
23
31-40-57
24-31-44
14-18-25
959
23
31-40-57
24-31-44
14-18-26
1043
24
32-42-59
25-33-46
15-19-27
1113
24
33-43-61
26-34-48
15-20-28
1134
24
34-44-62
26-34-48
15-20-28
1274
25
36-46-66
28-36-51
16-21-30
1449
25
38-49-70
29-38-54
17-22-31
1498
25
39-50-71
30-39-55
17-23-32
1603
26
40-52-74
31-40-57
18-23-33
1722
26
41-54-76
32-42-59
19-24-34
1799
26
42-55-78
33-43-60
19-25-35
1925
26
44-57-81
34-44-63
20-26-36

800
0.040
0.068
0.076
0.116
976
27
33-41-57
26-31-45
15-18-26
1080
27
35-43-60
27-33-47
16-19-27
1096
27
35-43-61
27-33-47
16-19-27
1192
28
37-45-63
28-35-49
16-20-29
1272
28
38-46-66
29-36-51
17-21-30
1296
28
38-47-66
30-36-51
17-21-30
1456
29
41-50-70
31-38-54
18-22-32
1656
29
43-53-75
33-41-58
19-24-34
1712
29
44-54-76
34-42-59
20-24-34
1832
30
45-56-79
35-43-61
20-25-35
1968
30
47-58-82
36-45-63
21-26-37
2056
30
48-59-83
37-46-65
22-27-38
2200
30
50-61-86
39-47-67
22-27-39

NC 40
1000
0.062
0.106
0.118
0.181
1220
34
37-45-64
29-35-50
17-20-29
1350
34
39-48-68
30-37-52
18-21-30
1370
34
39-48-68
30-37-53
18-22-31
1490
34
41-50-71
32-39-55
18-23-32
1590
35
42-52-73
33-40-57
19-23-33
1620
35
43-52-74
33-41-57
19-24-33
1820
35
45-55-78
35-43-61
20-25-35
2070
36
48-59-84
37-46-65
22-27-38
2140
36
49-60-85
38-47-66
22-27-38
2290
36
51-62-88
39-48-68
23-28-40
2460
36
53-64-91
41-50-71
24-29-41
2570
37
54-66-93
42-51-72
24-30-42
2750
37
56-68-96
43-53-75
25-31-43

Performance notes appear at end of table.


See the table, Correction Factors for Various Models on page G17 to determine appropriate factor.

1200
0.090
0.153
0.171
0.260
1464
39
41-50-70
31-39-55
18-22-32
1620
39
43-52-74
33-41-57
19-24-33
1644
39
43-53-75
33-41-58
19-24-34
1788
40
45-55-78
35-43-60
20-25-35
1908
40
46-57-80
36-44-62
21-26-36
1944
40
47-57-81
36-44-63
21-26-36
2184
41
50-61-86
38-47-67
22-27-39
2484
41
53-65-92
41-50-71
24-29-41
2568
41
54-66-93
42-51-72
24-30-42
2748
42
56-68-96
43-53-75
25-31-43
2952
42
58-71-100
45-55-77
26-32-45
3084
42
59-72-102
46-56-79
27-32-46
3300
42
61-75-106
47-58-82
27-34-48

1400
0.122
0.208
0.232
0.354
1708
44
44-54-76
34-42-59
20-24-34
1890
44
46-57-80
36-44-62
21-25-36
1918
44
46-57-81
36-44-62
21-26-36
2086
44
48-59-84
38-46-65
22-27-38
2226
45
50-61-87
39-48-67
23-28-39
2268
45
51-62-88
39-48-68
23-28-39
2548
45
54-66-93
42-51-72
24-30-42
2898
46
57-70-99
44-54-77
26-31-45
2996
46
58-71-101
45-55-78
26-32-45
3206
46
60-74-104
47-57-81
27-33-47
3444
47
62-76-108
48-59-84
28-34-49
3598
47
64-78-110
49-60-85
29-35-50
3850
47
66-81-114
51-63-88
30-36-51

PERFORMANCE DATA

Core Vel.
Nom. Nom.
Core Vel. Press.
Duct Duct
Area
0
Size Area
(ft2) Total 22.5
2
(in.) (ft )
Press. 45
cfm
NC
14x14 1.36 1.22
0
Throw 22.5
(ft)
45
cfm
36x6
NC
27x8 1.50 1.35
0
18x12
Throw 22.5
(ft)
45
cfm
NC
22x10 1.53 1.37
0
Throw 22.5
(ft)
45
cfm
30x8
NC
24x10 1.67 1.49
0
Throw 22.5
(ft)
45
cfm
42x6
NC
18x14 1.75 1.59
0
Throw 22.5
(ft)
45
cfm
NC
16x16 1.78 1.62
0
Throw 22.5
(ft)
45
cfm
48x6
36x8
NC
24x12 2.00 1.82
0
18x16
Throw 22.5
(ft)
45
cfm
NC
18x18 2.25 2.07
0
Throw 22.5
(ft)
45
cfm
42x8
NC
24x14 2.33 2.14
0
Throw 22.5
(ft)
45
cfm
36x10
NC
30x12 2.50 2.29
0
Throw 22.5
(ft)
45
cfm
48x8
NC
24x16 2.67 2.46
0
Throw 22.5
(ft)
45
cfm
NC
20x20 2.78 2.57
0
Throw 22.5
(ft)
45
cfm
36x12
NC
24x18 3.00 2.75
0
Throw 22.5
(ft)
45

NC 20

www.titus-hvac.com | www.titus-energysolutions.com

MODELS: 271, 272, 111, 112, 121, 122, 131 AND 132
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

G13

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

MODELS: 271, 272, 111, 112, 121, 122, 131 AND 132
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC 20

Nom.
Duct
Size
(in.)
48x10
30x16
24x20

22x22

42x12
36x14

24x22

30x18

48x12
36x16
24x24

36x18

36x20
30x24

PERFORMANCE DATA

42x18

28x28

42x20
30x28

48x18
36x24

30x30

G14

Core Vel.
Nom.
Core Vel. Press.
Duct
Area
0
Area
(ft2) Total 22.5
2
(ft )
Press. 45
cfm
NC
3.33 3.11
0
Throw 22.5
(ft)
45
cfm
NC
3.36 3.14
0
Throw 22.5
(ft)
45
cfm
NC
3.50 3.22
0
Throw 22.5
(ft)
45
cfm
NC
3.67 3.43
0
Throw 22.5
(ft)
45
cfm
NC
3.75 3.5
0
Throw 22.5
(ft)
45
cfm
NC
4.00 3.75
0
Throw 22.5
(ft)
45
cfm
NC
4.50 4.22
0
Throw 22.5
(ft)
45
cfm
NC
5.00 4.71
0
Throw 22.5
(ft)
45
cfm
NC
5.25 4.94
0
Throw 22.5
(ft)
45
cfm
NC
5.44 5.16
0
Throw 22.5
(ft)
45
cfm
NC
5.83 5.51
0
Throw 22.5
(ft)
45
cfm
NC
6.00 5.66
0
Throw 22.5
(ft)
45
cfm
NC
6.25 5.94
0
Throw 22.5
(ft)
45

300
0.006
0.010
0.011
0.016
933
18-30-56
14-23-44
8-13-25
942
19-30-56
14-23-44
8-14-25
966
19-30-57
15-24-44
8-14-26
1029
19-31-59
15-24-46
9-14-27
1050
20-32-60
15-25-46
9-14-27
1125
20-33-62
16-25-48
9-15-28
1266
21-35-65
17-27-51
10-16-29
1413
23-37-69
18-29-54
10-17-31
1482
23-38-71
18-29-55
10-17-32
1548
24-39-72
18-30-56
11-17-33
1653
25-40-75
19-31-58
11-18-34
1698
25-40-76
19-31-59
11-18-34
1782
25-41-78
20-32-60
11-19-35

400
0.010
0.017
0.019
0.029
1244
27-40-65
21-31-50
12-18-29
1256
27-40-65
21-31-50
12-18-29
1288
27-41-66
21-31-51
12-18-30
1372
28-42-68
22-33-53
13-19-31
1400
11
28-42-69
22-33-53
13-19-31
1500
11
29-44-71
23-34-55
13-20-32
1688
11
31-47-76
24-36-59
14-21-34
1884
12
33-49-80
25-38-62
15-22-36
1976
12
34-50-82
26-39-63
15-23-37
2064
12
34-51-84
27-40-65
15-23-38
2204
12
35-53-86
27-41-67
16-24-39
2264
13
36-54-87
28-42-68
16-24-39
2376
13
37-55-90
29-43-69
17-25-40

500
0.016
0.027
0.030
0.045
1555
17
33-50-72
26-39-56
15-22-33
1570
17
33-50-73
26-39-56
15-23-33
1610
17
34-51-74
26-39-57
15-23-33
1715
17
35-52-76
27-41-59
16-24-34
1750
17
35-53-77
27-41-60
16-24-35
1875
18
37-55-80
28-42-62
16-25-36
2110
18
39-58-84
30-45-65
17-26-38
2355
18
41-61-89
32-48-69
18-28-40
2470
19
42-63-91
33-49-71
19-28-41
2580
19
43-64-93
33-50-72
19-29-42
2755
19
44-66-96
34-51-75
20-30-43
2830
19
45-67-98
35-52-76
20-30-44
2970
19
46-69-100
36-53-78
21-31-45

600
0.022
0.038
0.043
0.065
1866
22
40-56-79
31-44-62
18-25-36
1884
22
40-56-80
31-44-62
18-25-36
1932
22
41-57-81
31-44-63
18-26-36
2058
23
42-59-83
33-46-65
19-27-38
2100
23
42-60-84
33-46-65
19-27-38
2250
23
44-62-87
34-48-68
20-28-39
2532
23
47-65-93
36-51-72
21-29-42
2826
24
49-69-98
38-54-76
22-31-44
2964
24
50-71-100
39-55-78
23-32-45
3096
24
51-72-102
40-56-79
23-33-46
3306
25
53-75-106
41-58-82
24-34-48
3396
25
54-76-107
42-59-83
24-34-48
3564
25
55-78-110
43-60-85
25-35-49

NC 30
700
0.031
0.052
0.058
0.089
2177
27
47-61-86
36-47-66
21-27-39
2198
27
47-61-86
36-47-67
21-27-39
2254
27
47-62-87
37-48-68
21-28-39
2401
27
49-64-90
38-49-70
22-29-41
2450
27
49-64-91
38-50-71
22-29-41
2625
28
51-67-94
40-52-73
23-30-42
2954
28
54-71-100
42-55-77
24-32-45
3297
29
57-75-106
44-58-82
26-34-48
3458
29
59-76-108
46-59-84
26-34-49
3612
29
60-78-110
47-61-86
27-35-50
3857
29
62-81-114
48-63-88
28-36-51
3962
29
63-82-116
49-63-90
28-37-52
4158
30
64-84-119
50-65-92
29-38-53

NC 40
800
0.040
0.068
0.076
0.116
2488
31
53-65-92
41-50-71
24-29-41
2512
31
53-65-92
41-50-71
24-29-41
2576
31
54-66-93
42-51-72
24-30-42
2744
31
56-68-96
43-53-75
25-31-43
2800
31
56-69-97
44-53-75
25-31-44
3000
32
58-71-101
45-55-78
26-32-45
3376
32
62-76-107
48-59-83
28-34-48
3768
33
65-80-113
50-62-87
29-36-51
3952
33
67-82-116
52-63-90
30-37-52
4128
33
68-84-118
53-65-92
31-38-53
4408
33
70-86-122
55-67-95
32-39-55
4528
33
71-87-124
55-68-96
32-39-56
4752
33
73-90-127
57-69-98
33-40-57

NC 50

1000
1200
1400
0.062
0.090
0.122
0.106
0.153
0.208
0.118
0.171
0.232
0.181
0.260
0.354
3110
3732
4354
37
43
48
59-72-103 65-79-112 70-86-121
46-56-79 50-62-87 54-66-94
27-33-46 29-36-51 32-39-55
3140
3768
4396
38
43
48
59-73-103 65-80-113 70-86-122
46-56-80 50-62-87 55-67-94
27-33-46 29-36-51 32-39-55
3220
3864
4508
38
43
48
60-74-104 66-81-114 71-87-123
47-57-81 51-63-89 55-68-96
27-33-47 30-36-51 32-39-56
3430
4116
4802
38
43
48
62-76-108 68-83-118 74-90-127
48-59-83 53-65-91 57-70-99
28-34-48 31-38-53 33-41-57
3500
4200
4900
38
43
48
63-77-109 69-84-119 74-91-129
49-60-84 53-65-92 58-71-100
28-35-49 31-38-54 33-41-58
3750
4500
5250
38
44
48
65-80-113 71-87-123 77-94-133
50-62-87 55-68-96 60-73-103
29-36-51 32-39-55 35-42-60
4220
5064
5908
39
44
49
69-84-119 76-93-131 82-100-141
53-65-93 59-72-101 63-77-110
31-38-54 34-42-59 37-45-64
4710
5652
6594
39
45
49
73-89-126 80-98-138 86-106-149
56-69-98 62-76-107 67-82-116
33-40-57 36-44-62 39-48-67
4940
5928
6916
49
39
45
75-91-129 82-100-142 88-108-153
58-71-100 63-78-110 68-84-118
34-41-58 37-45-64 40-49-69
6192
5160
7224
40
45
50
76-93-132 84-102-145 90-110-156
59-72-102 65-79-112 70-86-121
34-42-59 38-46-65
41-50-70
5510
6612
7714
40
45
50
79-96-136 86-106-149 93-114-161
61-75-106 67-82-116 72-88-125
35-43-61 39-48-67
42-51-73
5660
6792
7924
40
45
50
80-98-138 87-107-152 94-116-164
62-76-107 68-83-117 73-90-127
36-44-62 39-48-68
43-52-74
5940
7128
8316
40
46
50
82-100-142 90-110-155 97-119-168
63-78-110 69-85-120 75-92-130
37-45-64 40-49-70
44-53-75

Performance notes appear at end of table.


See the table, Correction Factors for Various Models on page G17 to determine appropriate factor.

AeroBlade Grilles

PERFORMANCE DATA

NC 20
400
0.010
0.017
0.019
0.029
2664
13
39-58-95
30-45-74
18-26-43
2672
13
39-59-95
30-45-74
18-26-43
2712
13
39-59-96
30-46-74
18-27-43
2864
14
40-61-98
31-47-76
18-27-44
3052
14
42-63-102
32-48-79
19-28-46
3072
14
42-63-102
32-49-79
19-28-46
3256
14
43-65-105
33-50-81
19-29-47
3352
14
44-66-106
34-51-82
20-29-48
3452
14
44-67-108
34-52-84
20-30-49
3840
15
47-70-114
36-54-88
21-32-51
3856
15
47-70-114
36-54-88
21-32-51
4040
15
48-72-117
37-56-91
22-32-53
4180
15
49-73-119
38-57-92
22-33-53

500
0.016
0.027
0.030
0.045
3330
20
49-73-106
38-57-82
22-33-48
3340
20
49-73-106
38-57-82
22-33-48
3390
20
49-74-107
38-57-83
22-33-48
3580
20
50-76-110
39-59-85
23-34-50
3815
20
52-78-114
40-61-88
23-35-51
3840
21
52-78-114
41-61-88
24-35-51
4070
21
54-81-117
42-63-91
24-36-53
4190
21
55-82-119
42-64-92
25-37-54
4315
21
55-83-121
43-64-94
25-37-54
4800
21
58-88-127
45-68-99
26-39-57
4820
21
59-88-128
45-68-99
26-40-57
5050
22
60-90-131
46-70-101
27-40-59
5225
22
61-92-133
47-71-103
27-41-60

600
0.022
0.038
0.043
0.065
3996
25
58-82-116
45-64-90
26-37-52
4008
25
59-82-116
45-64-90
26-37-52
4068
25
59-83-117
46-64-91
27-37-53
4296
26
61-85-121
47-66-93
27-38-54
4578
26
63-88-124
48-68-96
28-40-56
4608
26
63-88-125
49-68-97
28-40-56
4884
26
65-91-128
50-70-100
29-41-58
5028
26
66-92-130
51-71-101
29-41-59
5178
26
67-94-132
52-72-103
30-42-60
5760
27
70-99-140
54-76-108
32-44-63
5784
27
70-99-140
54-77-108
32-44-63
6060
27
72-101-143
56-78-111
32-46-64
6270
27
73-103-146
57-80-113
33-46-66

NC 40
700
0.031
0.052
0.058
0.089
4662
30
68-89-126
53-69-97
31-40-56
4676
30
68-89-126
53-69-97
31-40-57
4746
30
69-90-127
53-69-98
31-40-57
5012
30
71-92-130
55-71-101
32-41-59
5341
31
73-95-134
57-74-104
33-43-60
5376
31
73-95-135
57-74-104
33-43-61
5698
31
75-98-139
58-76-108
34-44-62
5866
31
76-100-141
59-77-109
34-45-63
6041
31
78-101-143
60-78-111
35-45-64
6720
32
82-107-151
63-83-117
37-48-68
6748
32
82-107-151
64-83-117
37-48-68
7070
32
84-109-155
65-85-120
38-49-70
7315
32
85-111-157
66-86-122
38-50-71

800
0.040
0.068
0.076
0.116
5328
34
77-95-134
60-74-104
35-43-60
5344
34
78-95-134
60-74-104
35-43-60
5424
34
78-96-135
61-74-105
35-43-61
5728
34
80-98-139
62-76-108
36-44-63
6104
35
83-102-144
64-79-111
37-46-65
6144
35
83-102-144
64-79-112
37-46-65
6512
35
86-105-148
66-81-115
39-47-67
6704
35
87-106-151
67-82-117
39-48-68
6904
35
88-108-153
68-84-118
40-49-69
7680
35
93-114-161
72-88-125
42-51-73
7712
36
93-114-161
72-88-125
42-51-73
8080
36
95-117-165
74-91-128
43-53-74
8360
36
97-119-168
75-92-130
44-53-76

NC 50
1000
0.062
0.106
0.118
0.181
6660
41
87-106-150
67-82-116
39-48-68
6680
41
87-106-150
67-82-116
39-48-68
6780
41
87-107-151
68-83-117
39-48-68
7160
41
90-110-156
70-85-121
40-50-70
7630
41
93-114-161
72-88-124
42-51-72
7680
41
93-114-161
72-88-125
42-51-73
8140
41
96-117-166
74-91-129
43-53-75
8380
42
97-119-168
75-92-130
44-54-76
8630
42
99-121-171
76-94-132
44-54-77
9600
42
104-127-180
81-99-140
47-57-81
9640
42
104-128-181
81-99-140
47-57-81
10100
42
107-131-185
83-101-143
48-59-83
10450
43
109-133-188
84-103-146
49-60-85

Performance notes appear at end of table.


See the table, Correction Factors for Various Models on page G17 to determine appropriate factor.

1200
0.090
0.153
0.171
0.260
7992
46
95-116-164
74-90-127
43-52-74
8016
46
95-116-165
74-90-128
43-52-74
8136
46
96-117-166
74-91-129
43-53-75
8592
46
98-121-170
76-93-132
44-54-77
9156
47
102-124-176
79-96-136
46-56-79
9216
47
102-125-176
79-97-137
46-56-79
9768
47
105-128-182
81-100-141
47-58-82
10056
47
106-130-184
82-101-143
48-59-83
10356
47
108-132-187
84-103-145
49-60-84
11520
48
114-140-197
88-108-153
51-63-89
11568
48
114-140-198
88-108-153
51-63-89
12120
48
117-143-202
91-111-157
53-64-91
12540
48
119-146-206
92-113-160
53-66-93

1400
0.122
0.208
0.232
0.354
9324
51
102-126-178
79-97-138
46-56-80
9352
51
103-126-178
80-97-138
46-57-80
9492
51
103-127-179
80-98-139
47-57-81
10024
51
106-130-184
82-101-143
48-59-83
10682
51
110-134-190
85-104-147
49-60-86
10752
51
110-135-191
85-104-148
50-61-86
11396
52
113-139-196
88-108-152
51-62-88
11732
52
115-141-199
89-109-154
52-63-90
12082
52
117-143-202
90-111-157
53-64-91
13440
52
123-151-213
95-117-165
55-68-96
13496
52
123-151-214
96-117-166
55-68-96
14140
52
126-155-219
98-120-169
57-70-98
14630
53
128-157-222
99-122-172
58-71-100

PERFORMANCE DATA

Core Vel.
300
Nom. Nom.
Core Vel. Press.
0.006
Duct Duct
Area
0
0.010
Size Area
(ft2) Total 22.5 0.011
2
(in.) (ft )
Press. 45 0.016
cfm
1998
42x24
NC
36x28 7.00 6.66
0 27-44-82
Throw 22.5 21-34-64
(ft)
45 12-20-37
cfm
2004
NC
46x22 7.03 6.68
0 27-44-82
Throw 22.5 21-34-64
(ft)
45 12-20-37
cfm
2034
NC
32x32 7.11 6.78
0 27-44-83
Throw 22.5 21-34-64
(ft)
45 12-20-37
cfm
2148
NC
36x30 7.50 7.16
0 28-45-85
Throw 22.5 22-35-66
(ft)
45 13-20-38
cfm
2289
48x24
NC
36x32 8.00 7.63
0 29-47-88
Throw 22.5 22-36-68
(ft)
45 13-21-40
cfm
2304
NC
34x34 8.03 7.68
0 29-47-88
Throw 22.5 22-36-68
(ft)
45 13-21-40
cfm
2442
NC
36x34 8.50 8.14
0 30-48-91
Throw 22.5 23-38-70
(ft)
45 13-22-41
cfm
2514
NC
42x30 8.75 8.38
0 30-49-92
Throw 22.5 23-38-71
(ft)
45 14-22-41
cfm
2589
NC
36x36 9.00 8.63
0 31-50-94
Throw 22.5 24-39-72
(ft)
45 14-22-42
cfm
2880
42x34
NC
48x30 10.00 9.6
0 32-53-99
Throw 22.5 25-41-76
(ft)
45 15-24-44
cfm
2892
NC
38x38 10.03 9.64
0 32-53-99
Throw 22.5 25-41-77
(ft)
45 15-24-44
cfm
3030
NC
42x36 10.50 10.1
0 33-54-101
Throw 22.5 26-42-78
(ft)
45 15-24-46
cfm
3135
NC
46x34 10.86 10.45
0 34-55-103
Throw 22.5 26-43-80
(ft)
45 15-25-46

NC 30

www.titus-hvac.com | www.titus-energysolutions.com

MODELS: 271, 272, 111, 112, 121, 122, 131, AND 132
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

G15

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

MODELS: 271, 272, 111, 112, 121, 122, 131, AND 132
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC 20
Core Vel.
Nom. Nom.
Core Vel. Press.
Duct Duct
Area
0
Size Area
(ft2) Total 22.5
2
(in.) (ft )
Press. 45
cfm
NC
42x38 11.08 10.67
0
Throw 22.5
(ft)
45
cfm
NC
40x40 11.11 10.7
0
Throw 22.5
(ft)
45
cfm
NC
48x36 12.00 11.57
0
Throw 22.5
(ft)
45
cfm
NC
42x42 12.25 11.82
0
Throw 22.5
(ft)
45
cfm
NC
44x44 13.44 12.99
0
Throw 22.5
(ft)
45
cfm
NC
48x42 14.00 13.54
0
Throw 22.5
(ft)
45
cfm
NC
46x46 14.69 14.22
0
Throw 22.5
(ft)
45
cfm
NC
48x46 15.33 14.85
0
Throw 22.5
(ft)
45
cfm
NC
48x48 16.00 15.50
0
Throw 22.5
(ft)
45

300
0.006
0.010
0.011
0.016
3201
34-55-104
26-43-81
15-25-47
3210
34-56-104
26-43-81
15-25-47
3471
36-58-108
28-45-84
16-26-49
3546
36-58-109
28-45-85
16-26-49
3897
38-61-115
29-47-89
17-28-52
4062
38-62-117
30-48-91
17-28-53
4266
39-64-120
31-50-93
18-29-54
4455
40-65-123
31-51-95
18-29-55
4650
41-67-125
32-52-97
19-30-56

400
0.010
0.017
0.019
0.029
4268
15
49-74-120
38-57-93
22-33-54
4280
15
49-74-120
38-57-93
22-33-54
4628
16
51-77-125
40-60-97
23-35-56
4728
16
52-78-126
40-60-98
23-35-57
5196
16
54-82-133
42-63-103
24-37-60
5416
16
56-83-135
43-65-105
25-37-61
5688
16
57-85-139
44-66-107
26-38-62
5940
17
58-87-142
45-68-110
26-39-64
6200
17
59-89-145
46-69-112
27-40-65

NC 30
500
0.016
0.027
0.030
0.045
5335
22
62-92-134
48-72-104
28-42-60
5350
22
62-93-134
48-72-104
28-42-61
5785
22
64-96-140
50-75-108
29-43-63
5910
22
65-97-141
50-75-110
29-44-64
6495
23
68-102-148
53-79-115
31-46-67
6770
23
69-104-151
54-81-117
31-47-68
7110
23
71-107-155
55-83-120
32-48-70
7425
23
73-109-158
56-85-123
33-49-71
7750
23
74-111-162
58-86-125
33-50-73

600
0.022
0.038
0.043
0.065
6402
27
74-104-147
57-81-114
33-47-66
6420
27
74-104-147
57-81-114
33-47-66
6942
28
77-108-153
60-84-119
35-49-69
7092
28
78-109-155
60-85-120
35-49-70
7794
28
82-115-162
63-89-126
37-52-73
8124
28
83-117-166
65-91-128
37-53-75
8532
29
85-120-170
66-93-132
38-54-76
8910
29
87-123-174
68-95-134
39-55-78
9300
29
89-125-177
69-97-137
40-56-80

0, 22.5, and 45 represent blade deflection angles.


Performance data is based on duct sizes
in bold, the performance varies slightly
for duct sizes not shown in bold.
See the section, Engineering Guidelines,
for drop information, when selecting larger
supply grilles for cooling purposes.

Note: The performance data for Correction Factors by Model is


on page G17.

G16

NC 40
700
800
0.031
0.040
0.052
0.068
0.058
0.076
0.089
0.116
7469
8536
32
36
86-112-159 98-120-170
67-87-123 76-93-132
39-51-71
44-54-76
7490
8560
32
36
86-113-159 98-120-170
67-87-123 76-93-132
39-51-72
44-54-77
8099
9256
32
36
90-117-165 102-125-177
70-91-128 79-97-137
40-53-74
46-56-80
8274
9456
32
36
91-118-167 103-126-179
70-92-130 80-98-139
41-53-75
46-57-80
9093
10392
33
37
95-124-175 108-133-187
74-96-136 84-103-145
43-56-79
49-60-84
9478
10832
33
37
97-127-179 110-135-191
75-98-139 86-105-148
44-57-81
50-61-86
9954
11376
33
37
100-130-183 113-139-196
77-101-142 88-107-152
45-58-83
51-62-88
10395
11880
33
37
102-133-187 116-142-200
79-103-145 90-110-155
46-60-84
52-64-90
10850
12400
34
37
104-135-192 118-145-205
81-105-148 92-112-159
47-61-86
53-65-92

NC 50
1000
0.062
0.106
0.118
0.181
10670
43
110-134-190
85-104-147
49-60-85
10700
43
110-134-190
85-104-147
49-61-86
11570
43
114-140-198
88-108-153
51-63-89
11820
43
115-141-200
89-110-155
52-64-90
12990
43
121-148-210
94-115-162
54-67-94
13540
44
124-151-214
96-117-166
56-68-96
14220
44
127-155-219
98-120-170
57-70-99
14850
44
129-158-224
100-123-174
58-71-101
15500
44
132-162-229
102-125-177
59-73-103

1200
0.090
0.153
0.171
0.260
12804
48
120-147-208
93-114-161
54-66-94
12840
48
120-147-208
93-114-161
54-66-94
13884
48
125-153-217
97-119-168
56-69-97
14184
48
126-155-219
98-120-170
57-70-99
15588
49
133-162-230
103-126-178
60-73-103
16248
49
135-166-234
105-128-182
61-75-105
17064
49
139-170-240
107-132-186
62-76-108
17820
49
142-174-245
110-134-190
64-78-110
18600
50
145-177-251
112-137-194
65-80-113

1400
0.122
0.208
0.232
0.354
14938
53
130-159-225
101-123-174
58-71-101
14980
53
130-159-225
101-123-174
58-72-101
16198
53
135-165-234
105-128-181
61-74-105
16548
53
137-167-236
106-130-183
61-75-106
18186
53
143-175-248
111-136-192
64-79-112
18956
54
146-179-253
113-139-196
66-81-114
19908
54
150-183-259
116-142-201
67-83-117
20790
54
153-187-265
119-145-205
69-84-119
21700
54
156-192-271
121-148-210
70-86-122

See the Performance Notes portion in this


section for notes and correction factors.
See the section, Engineering Guidelines
for catalog throw information.
Each NC value represents the noise criteria curve
that will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with
a room absorption of 10 dB, re 10-12 watts.

AeroBlade Grilles

PERFORMANCE DATA

Drop Versus Throw Showing Ceiling Effect - 20F DT Cooling


TYPICAL 100 fpm ENVELOPE

Performance data
includes damper.
Drop, Ft.

700
500

1500

2000 CFM

Y
IT
OC

20

10

20

30
Throw, Ft.
(Side view of air jet leaving wall mounted grille)

40

150

0 fp

pm

1000

JE

1500

TV

15

OCIT

1000

500

FM
2000 C

ITY

OC

EL

Model
271, 272
111,112
121,122
131,132

40

50

Damper

Ak /Ac

Throw

Total
Pressure

NC

With
Without
With
Without
With
Without
With
Without

0.78
0.83
0.87
0.92
0.92
0.98
0.92
0.98

1.00
0.97
0.95
0.92
0.92
0.89
0.92
0.89

1.00
0.88
0.81
0.72
0.72
0.64
0.72
0.64

0
-4
0
-5
0
-5
0
-5

Note: Throw and total pressure corrections are multipliers. The NC


correction is an addition. Ak is the flow factor. Ac is the core area
from the main table.

PERFORMANCE DATA

Variable Air Volume Applications


All Titus supply grilles can be applied
to variable air volume systems
with excellent results. For detailed
selection methods, consult your Titus
representative or the Engineering
Guidelines section of this catalog.

ET V
EL

0f

Dash () in space indicates NC


value less than 10.

mJ

20
The stated deflection settings
0
10
20
30
refer to the horizontal setting of
Throw, Ft.
the blades deflection angle. For
(Side view of air jet leaving wall mounted grille)
a 20 upward deflection, use the
throw rating for the 0 setting and
the total pressure for the 22
horizontal setting.
Correction Factors for AeroBlade Supply Grilles

See the section, Engineering


Guidelines for drop and
throw information.

50

700

30

Drop, Ft.

Drop Versus Throw without Ceiling Effect


Each NC value represents the
TYPICAL 100 fpm ENVELOPE
noise criterion curve that will
not be exceeded by the sound
pressure in any of the octave
0
bands, 2 through 7. Each NC
100 CFM
value is further based on a grille
200
operating at a 0 deflection. For
5
deflection settings of 22 or 45,
400
600
increase the stated sound levels
10
800
by 1 or 7 NC, respectively.
Bold dividing lines on each table
denote ranges of NC values.

ET VE
LO

CITY

1000

15

fpm J

1000

EL

Throw values are given for


isothermal terminal velocities of
150, 100 and 50 fpm.

10

TV
JE

Core velocities are in feet


per minute.

pm
0f

All pressures are in inches


of water.

1500

100 CFM
200
400
600
800
30

Data obtained from tests


conducted in accordance with
ANSI/ASHRAE Standard 70-2006.

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE NOTES

G17

AeroBlade Grilles
0B Horizontal Deflection
10

SUPPLY GRILLES

Diagrams are based on actual tests


conducted by Titus. They show the
relationship of spread to throw for a
typical high side-wall supply outlet
selection.
Notice the outer shaded area
represents the 50 fpm isovel, the
white area the 100 fpm isovel, and
the inner area the 150 fpm isovel.
The spread angle also affects the
amount of drop of the airstream.
For a given temperature, volume,
and core velocity, the wider the
spread the smaller the drop. See the
section, Engineering Guidelines for
drop and throw information.
Titus grilles can be selected with
a single set of blades for adjusting
either horizontal or vertical
deflection, or with two sets of blades
for adjusting both horizontal and
vertical deflections.

0
DEFLECTION

50 fpm

Typical 100 fpm Envelope


150 fpm

5
10

10

20

30

40

50

THROW, FEET

Spread versus throw at 0 horizontal deflection angle (Plan view of air jet leaving
wall mounted grille).
22B Horizontal Deflection
10

22

1/2

0
22 1/
2

SPREAD, FEET

HORIZONTAL DEFLECTION
(SPREAD)

SPREAD, FEET

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

50 fpm
Typical 100 fpm
Envelope

150 fpm

221/2
DEFLECTION

10

10

20

30

40

THROW, FEET

Spread versus throw at 22 horizontal deflection angle (Plan view of air jet leaving
wall mounted grille).
45B Horizontal Deflection

20
15
50 fpm

45

0
45

SPREAD, FEET

PERFORMANCE DATA

10
5

Typical 100
fpm Envelope

0
150 fpm

45
DEFLECTION

10

Spread versus throw at 45


horizontal deflection angle
(Plan view of air jet leaving
wall mounted grille).

15
20
0

10

15

THROW, FEET

G18

20

25

AeroBlade Grilles

SUGGESTED SPECIFICATIONS

Available Models:
271RL/271RS
272RL/272RS
111RL/111RS
112RL/112RS
121RL/121RS
122RL/122RS
131RL/131RS
132RL/132RS
Steel supply grilles shall be Titus AeroBlade Series
Model271R, 111R, 121R, or 131R (single deflection) or
272R, 112R, 122R or 132R (double deflection) for the sizes
and mounting types as shown on the plans and outlet
schedule. The deflection blades shall be available parallel to
the long or short dimension of the grille. All supply grilles
shall be constructed with a 1-inch wide steel border
having a minimum thickness of 20-gauge. Corners shall
be assembled with full penetration resistance welds with a
reinforcing steel patch for extra strength. Screw holes shall
be countersunk for a neat appearance.
Blades shall be constructed of heavy duty aluminum and
shall be contoured to a specifically designed airfoil
cross-section to meet published performance data. Hollow

Optional opposed blade volume damper shall be constructed


of heavy gauge steel. Damper must be operable from the
face of the grille.
The grille finish shall be #26 white. The finish shall be
an anodic acrylic paint, baked at 315F for 30 minutes.
The pencil hardness must be HB to H. The paint must
pass a 100-hour ASTM B117 Corrosive Environments Salt
Spray Test without creepage, blistering, or deterioration of
film. The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

www.titus-hvac.com | www.titus-energysolutions.com

blades are not acceptable. Blades must be solid. Blades


shall be spaced -inch (Models 271RL, 271RS, 272RL,
and 272RS), 1 inches (Models 111RL, 111RS, 112RL and
112RS), 2 inches (121RL, 121RS, 122RL and 122RS), or
3 inches (131RL, 131RS, 132RL and 132RS) apart. Blades
shall extend completely through the side frame on each side
to ensure stability throughout the complete cfm operating
range of the grille. Blades shall be individually adjustable
without loosening or rattling and shall be securely held in
place with tension wire.

AEROBLADE SUPPLY GRILLES - STEEL

MODEL NUMBER SPECIFICATION


Model
271
272
111
112
121
122
131
132

Single Deflection, Spacing


Double Deflection, Spacing
Single Deflection, 1 Spacing
Double Deflection, 1 Spacing
Single Deflection, 2 Spacing
Double Deflection, 2 Spacing

Width
Border Type
Surface Mount

Single Deflection, 3 Spacing


Double Deflection, 3 Spacing

XXX

X
Height

White (std.)

S
L

Parallel to Short Dim.

Aluminum
Colored Paint

Steel
Front Blade
Orientation

Parallel to Long Dim.

XX

XX-XX

XX

26
01

Steel Plaster
Frame

PF

Optional
Finish

SPECIFICATIONS

Material

Optional Damper
AG-35 Steel

G19

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

spaced -inch (Models 271FL, 271FS, 272FL and 272FS)


apart. Blades shall extend completely through the side frame
on each side to ensure stability throughout the complete
cfm operating range of the grille. Blades shall be individually
adjustable without loosening or rattling and shall be securely
held in place with tension wire.

AEROBLADE SUPPLY GRILLES - ALUMINUM


Available Models:
271FL/271FS
272FL/272FS
Aluminum supply grilles shall be Titus AeroBlade Series
Model 271F (single deflection) or 272F (double deflection)
for the sizes and mounting types as shown on the plans
and outlet schedule. The deflection blades shall be available
parallel to the long or short dimension of the grille. All
supply grilles shall be constructed with a 1-inch wide
heavy aluminum border having a minimum thickness of
0.040-0.050 inch. Outer borders shall be assembled and
interlocked at the four corners and mechanically staked to
form a rigid frame. Screw holes shall be countersunk for a
neat appearance.

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel or aluminum. Damper must be
operable from the face of the grille. The grille finish shall be
#26 white. The finish shall be an anodic acrylic paint, baked
at 315F for 30 minutes. The pencil hardness must be HB
to H. The paint must pass a 100-hour ASTM B117 Corrosive
Environments Salt Spray Test without creepage, blistering or
deterioration of film. The paint must pass a 250-hour ASTM
D870 Water Immersion Test. The paint must also pass the
ASTM D2794 Reverse Impact Cracking Test with a 50-inch
pound force applied.

Blades shall be constructed of heavy duty aluminum and


shall be contoured to a specifically designed airfoil crosssection to meet published performance data. Hollow blades
are not acceptable. Blades must be solid. Blades shall be

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Model
271
272

Width
Double Deflection, Spacing

XXX
Material

X
Height

White (std.)

S
L

Parallel to Short Dim.

Aluminum
Colored Paint

Aluminum

Front Blade
Orientation

Optional Damper
Steel
AG-35
AG-35-AA Aluminum

Border Type
Surface Mount

Single Deflection, Spacing

Parallel to Long Dim.

XX
26
01

SPECIFICATIONS

XX

Steel Plaster
Frame

PF

Optional
Finish

G20

XX-XX-XX

AeroBlade Grilles
23 (RL, RS)

-INCH SPACING - STEEL


Available 45 Deflection Models:
23RL
23RS
Products Include:
Material: Roll-formed Steel.
Welded Border.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#2 - Snap-In
#3 - Lay-In
#4 - Spline
Countersunk Screw Holes.
#8 x 1-inch Long Phillips Flat Head Sheet
Metal Screws, Painted White.
Optional Steel Opposed-Blade Damper.

23RL
-inch blade spacing.
45 fixed deflection.
Reinforced corners.
Blades parallel to the
long dimension.
20-gauge border.

23RS
Same as 23RL with blades parallel to the short
dimension.

For Performance Data, please refer to page G27.


For Suggested Specification, please refer to
page G35.

www.titus-hvac.com | www.titus-energysolutions.com

AeroBlade Return Grilles


23 (RL, RS)

45 Deflection Models: 23RL/23RS - Border Type 1


D plus 1"
1"
9/16"

D minus "
"

"

Optional
Opposed
Blade
Damper

1"

2"

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.

23 (RL, RS)

All dimensions are in inches.

G21

AeroBlade Grilles

3, 56 (FL, FS)
Available 45 Deflection Models:
3FL
3FS
Available 0 Deflection Models:
56FL
56FS
Products Include:
Material: Extruded Aluminum.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#2 - Snap-In
#3 - Lay-In
#4 - Spline
Countersunk Screw Holes.
#8 x 1-inch Long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel or Aluminum OpposedBlade Damper.

3FL
-inch blade spacing.
45 fixed deflection.
Reinforced corners.
Front blades parallel to the
long dimension.
Extruded aluminum border.

56FL
-inch blade spacing.
0 fixed deflection.
Reinforced corners.
Front blades parallel to the
long dimension.
Extruded aluminum border.

3FS
Same as 3FL with blades parallel
to the short dimension.

56FS
Same as 56FL with front blades
parallel to the short dimension.

45 Deflection Models: 3FL/3FS - Border Type 1


D plus 1"
1"

For Performance Data, please refer to page


G31 for 3(FL/FS) and page G33 for 56(FL/FS).
For Suggested Specification, please refer to
page G36.

56 (FL, FS)

-INCH SPACING - ALUMINUM


3 (FL, FS)

www.titus-hvac.com | www.titus-energysolutions.com

AeroBlade Return Grilles (continued)

9/16"

D minus "
"

Optional
Opposed
Blade
Damper

3/16"

1"

2"

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
0 Deflection Models: 56FL/56FS - Border Type 1
D plus 1"
1"

3, 56 (FL, FS)

9/16"

D minus "
"

Optional
Opposed
Blade
Damper

3/16"

2"
1"

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.

G22

All dimensions are in inches.

AeroBlade Grilles

AeroBlade Return Grilles (continued)

25 (RL, RS)

-INCH SPACING - STEEL


Available 30 Deflection Models:
25RL
25RS
Products Include:
Material: Roll-formed Steel.
Welded Border.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#2 - Snap-In
#3 - Lay-In
#4 - Spline
Countersunk Screw Holes.
#8 x 1-inch Long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel Opposed-Blade Damper.

25RL
-inch blade spacing.
30 fixed deflection.
Reinforced corners.
Blades parallel to the
long dimension.
20-gauge border.

30 Deflection Models: 25RL/25RS - Border Type 1


D plus 1"

For Performance Data, please refer to page


G29.
For Suggested Specification, please refer to
page G35.

25RS
Same as 25RL with blades parallel
to the short dimension.

1"

9/16"

D minus "
"

Optional
Opposed
Blade
Damper

www.titus-hvac.com | www.titus-energysolutions.com

25 (RL, RS)

"

1"

2"

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.

25 (RL, RS)

All dimensions are in inches.

G23

AeroBlade Grilles

4, 55 (FL, FS)
45 Deflection Models:
4FL
4FS
0 Deflection Models:
55FL
55FS
Products Include:
Material: Extruded Aluminum.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#2 - Snap-In
#3 - Lay-In
#4 - Spline
Countersunk Screw Holes.
#8 x 1-inch Long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel or Aluminum OpposedBlade Damper.

4FL
-inch blade spacing.
45 fixed deflection.
Reinforced corners.
Front blades parallel to the
long dimension.
Extruded aluminum border.

55FL
-inch blade spacing.
0 fixed deflection.
Reinforced corners.
Front blades parallel to the
long dimension.
Extruded aluminum border.

4FS
Same as 4FL with blades parallel
to the short dimension.

55FS
Same as 55FL with front blades
parallel to the short dimension.

45 Deflection Models: 4FL/4FS - Border Type 1


D plus 1"
1"

For Performance Data, please refer


to page G31 for 3(FL/FS) and page
G33 for 55(FL/FS).
For Suggested Specification, please refer to
page G36.

55 (FL, FS)

-INCH SPACING - ALUMINUM


4 (FL, FS)

www.titus-hvac.com | www.titus-energysolutions.com

AeroBlade Return Grilles (continued)

9/16"

D minus "
"

Optional
Opposed
Blade
Damper

3/16"

2"
1"

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
0 Deflection Models: 55FL/55FS - Border Type 1
D plus 1"
1"

4, 55 (FL, FS)

9/16"

D minus "
"

Optional
Opposed
Blade
Damper

3/16"

1"

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.

G24

All dimensions are in inches.

2"

AeroBlade Grilles

AeroBlade Return Grilles (continued)

45 Deflection Models:

23RL-NT
Long Blades



-inch Spacing

23RS-NT
Short Blades



-inch Spacing

3FL-NT
Long Blades



-inch Spacing

3FS-NT
Short Blades



-inch Spacing

4FL-NT
Long Blades



-inch Spacing

4FS-NT
Short Blades



-inch Spacing
0 Deflection Models:

56FL-NT
Long Blades



-inch Spacing

56FS-NT
Short Blades



-inch Spacing

55FL-NT
Long Blades



-inch Spacing

55FS-NT
Short Blades



-inch Spacing
30 Deflection Models:

25RL-NT
Long Blades



-inch Spacing

25RS-NT
Short Blades



-inch Spacing

Narrow Tee Return Grilles

24"
Nominal Duct Size D"
D minus "

D minus "
23"

Optional
Opposed
Blade
Damper

www.titus-hvac.com | www.titus-energysolutions.com

NARROW TEE RETURN GRILLES

23"

Note: Blade spacing and angle vary by model. 45 blade shown above.

Border Type NT

1"

Products Include:
5/16"
Standard Finish - #26 White.
Available Narrow Tee models are
available in 24 x 24-inch module sizes
with grilles from 6 x 6 inches through 20
x 20 inches in 2-inch increments.

9/16"

NARROW TEE RETURN GRILLES

For Performance Data and Suggested


Specification, please refer to base model
located in this section.

All dimensions are in inches.

G25

AeroBlade Grilles

FILTER RETURN GRILLES


G26

Available 45 Deflection Models:



23RFL
Long Blades



-inch Spacing

23RFS
Short Blades



-inch Spacing

3FFL
Long Blades



-inch Spacing

3FFS
Short Blades



-inch Spacing

4FFL
Long Blades



-inch Spacing

4FFS
Short Blades



-inch Spacing

45 Deflection Models: 23RFL - Border Type 1 & 3

FASTENER

HINGE
D PLUS 3 3/4"
1/2

7/16

1 1/4

2 5/32" FOR 1" FILTER


3 3/16" FOR 2" FILTER
NOMINAL DUCT SIZE (D)

Available 0 Deflection Models:



56FFL
Long Blades



-inch Spacing

56FFS
Short Blades



-inch Spacing

55FFL
Long Blades



-inch Spacing

55FFS
Short Blades



-inch Spacing

D PLUS 1/4"

Duct opening should be nominal duct size (D) plus 1/4.


Side Cross-Sectional View:
Border Type 1 (Surface Mount) & Border Type 3 (Lay-in T-Bar).
D PLUS 3 3/4"

45 Deflection Models: 4FFL - Border Type 1 & 3

Available 30 Deflection Models:



25RFL
Long Blades



-inch Spacing

25RFS
Short Blades



-inch Spacing
Products Include:
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#3 - Lay-In
Available Sizes (D x D)
Border Type 1 is available in sizes
6 x 6 inches through 48 x 36
inches in 1-inch increments.
Oversize and fractional size filter
return grilles are not available
1-inch Filter Frame
For Performance Data and Suggested
Specification, please refer to base model
located in this section.

FASTENER

HINGE

D PLUS 3 3/4"
1/2

7/16

1 1/4

2" FOR 1" FILTER


3 1/8" FOR 2" FILTER

D PLUS 3 3/4"

FILTER RETURN GRILLES

NOMINAL DUCT SIZE (D)


D PLUS 1/4"

Duct opening should be nominal duct size (D) plus 1/4.


Side Cross-Sectional View:
Border Type 1 (Surface Mount) & BorderDType
3 (Lay-in T-Bar).
PLUS 3 3/4"
Please refer to page I68
for Hinge Locations

Note: Add pressure drop for the


installed filter.
D PLUS 3 3/4"

www.titus-hvac.com | www.titus-energysolutions.com

AeroBlade Return Grilles (continued)

All dimensions are in inches.

AeroBlade Grilles

PERFORMANCE DATA

NC20

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC40

150
200
250
300
400
500
600
700
800
0.001 0.003 0.004 0.006 0.010 0.016 0.022 0.031 0.040
0.012 0.021 0.033 0.048 0.085 0.133 0.192 0.261 0.341
29
39
51
56
62
72
86
89
95
108
116
132
167
183
203
206
224
239
243
273
311
321
344
369
386
413
467
471
483
515
525
-

38
52
68
74
82
96
114
118
126
144
154
176
222
244
270
274
298
318
324
11
364
11
414
12
428
12
458
12
492
12
514
13
550
13
622
13
628
13
644
13
686
14
700
14

48
65
85
93
103
120
11
143
12
148
12
158
12
180
13
193
13
220
14
278
15
305
15
338
15
343
15
373
16
398
16
405
16
455
17
518
17
535
17
573
18
615
18
643
18
688
18
778
19
785
19
805
19
858
19
875
20

57
12
78
13
102
14
111
14
123
15
144
16
171
16
177
16
189
17
216
17
231
18
264
18
333
19
366
20
405
20
411
20
447
20
477
21
486
21
546
21
621
22
642
22
687
22
738
23
771
23
825
23
933
24
942
24
966
24
1029
24
1050
24

76
19
104
20
136
21
148
22
164
22
192
23
228
24
236
24
252
24
288
25
308
25
352
25
444
26
488
27
540
27
548
27
596
28
636
28
648
28
728
29
828
29
856
29
916
30
984
30
1028
30
1100
30
1244
31
1256
31
1288
31
1372
31
1400
31

95
25
130
26
170
27
185
27
205
28
240
29
285
29
295
29
315
30
360
30
385
31
440
31
555
32
610
33
675
33
685
33
745
33
795
34
810
34
910
34
1035
35
1070
35
1145
35
1230
36
1285
36
1375
36
1555
37
1570
37
1610
37
1715
37
1750
37

114
29
156
31
204
32
222
32
246
32
288
33
342
34
354
34
378
34
432
35
462
35
528
36
666
37
732
37
810
38
822
38
894
38
954
38
972
38
1092
39
1242
40
1284
40
1374
40
1476
40
1542
40
1650
41
1866
41
1884
41
1932
41
2058
42
2100
42

133
33
182
34
238
36
259
36
287
36
336
37
399
38
413
38
441
38
504
39
539
39
616
40
777
41
854
41
945
42
959
42
1043
42
1113
42
1134
42
1274
43
1449
43
1498
44
1603
44
1722
44
1799
44
1925
45
2177
45
2198
45
2254
45
2401
46
2450
46

152
36
208
38
272
39
296
39
328
40
384
40
456
41
472
41
504
42
576
42
616
43
704
43
888
44
976
45
1080
45
1096
45
1192
45
1272
46
1296
46
1456
46
1656
47
1712
47
1832
47
1968
48
2056
48
2200
48
2488
49
2512
49
2576
49
2744
49
2800
49

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

Nominal Nominal Core


Core Velocity
Duct
Duct
Area
Velocity Pressure
Size
Area
( ft2 ) Neg. Static Pressure
( in. )
( ft2 )
6x6
0.25
0.19
Airflow, cfm
NC
8x6
0.33
0.26
Airflow, cfm
NC
10x6
0.42
0.34
Airflow, cfm
NC
8x8
0.44
0.37
Airflow, cfm
NC
12x6
0.50
0.41
Airflow, cfm
NC
14x6
0.58
0.48
Airflow, cfm
NC
16x6
Airflow, cfm
12x8
0.67
0.57
NC
Airflow, cfm
10x10
0.69
0.59
NC
Airflow, cfm
18x6
0.75
0.63
NC
20x6
Airflow, cfm
12x10
0.83
0.72
NC
Airflow, cfm
22x6
0.92
0.77
NC
24x6
Airflow, cfm
12x12
1.00
0.88
NC
30x6
Airflow, cfm
18x10
1.25
1.11
NC
Airflow, cfm
14x14
1.36
1.22
NC
36x6
Airflow, cfm
18x12
1.50
1.35
NC
Airflow, cfm
22x10
1.53
1.37
NC
30x8
Airflow, cfm
24x10
1.67
1.49
NC
42x6
Airflow, cfm
18x14
1.75
1.59
NC
16x16
1.78
1.62
Airflow, cfm
NC
24x12
2.00
1.82
Airflow, cfm
18x16
NC
18x18
2.25
2.07
Airflow, cfm
NC
24x14
2.33
2.14
Airflow, cfm
NC
30x12
2.50
2.29
Airflow, cfm
NC
24x16
2.67
2.46
Airflow, cfm
NC
20x20
2.78
2.57
Airflow, cfm
NC
36x12
3.00
2.75
Airflow, cfm
NC
30x16
3.33
3.11
Airflow, cfm
24x20
NC
Airflow, cfm
22x22
3.36
3.14
NC
42x12
Airflow, cfm
36x14
3.50
3.22
NC
Airflow, cfm
24x22
3.67
3.43
NC
Airflow, cfm
30x18
3.75
3.5
NC

NC30

www.titus-hvac.com | www.titus-energysolutions.com

23R -INCH 45B DEFLECTION


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

G27

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

G28

23R -INCH 45B DEFLECTION (continued)


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-20
Nominal Nominal Core
Core Velocity
Duct
Duct
Area
Velocity Pressure
Size
Area
( ft2 ) Neg. Static Pressure
( in. )
( ft2 )
48x12
Airflow, cfm
24x24
4.00
3.75
NC
Airflow, cfm
36x18
4.50
4.22
NC
36x20
Airflow, cfm
30x24
5.00
4.71
NC
Airflow, cfm
42x18
5.25
4.94
NC
Airflow, cfm
28x28
5.44
5.16
NC
42x20
Airflow, cfm
30x28
5.83
5.51
NC
48x18
Airflow, cfm
36x24
6.00
5.66
NC
Airflow, cfm
30x30
6.25
5.94
NC
42x24
Airflow, cfm
36x28
7.00
6.66
NC
Airflow, cfm
46x22
7.03
6.68
NC
Airflow, cfm
32x32
7.11
6.78
NC
Airflow, cfm
36x30
7.50
7.16
NC
48x24
Airflow, cfm
36x32
8.00
7.63
NC
Airflow, cfm
34x34
8.03
7.68
NC
Airflow, cfm
36x34
8.50
8.14
NC
Airflow, cfm
42x30
8.75
8.38
NC
Airflow, cfm
36x36
9.00
8.63
NC
42x34
Airflow, cfm
48x30
10.00
9.6
NC
Airflow, cfm
38x38
10.03
9.64
NC
Airflow, cfm
42x36
10.50
10.1
NC
Airflow, cfm
46x34
10.86 10.45
NC
Airflow, cfm
42x38
11.08 10.67
NC
Airflow, cfm
40x40
11.11
10.7
NC
Airflow, cfm
48x36
12.00 11.57
NC
Airflow, cfm
42x42
12.25 11.82
NC
Airflow, cfm
44x44
13.44 12.99
NC
Airflow, cfm
48x42
14.00 13.54
NC
Airflow, cfm
46x46
14.69 14.22
NC
Airflow, cfm
48x46
15.33 14.85
NC
Airflow, cfm
48x48
16.00 15.50
NC

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC-30

NC-40

NC-50

150
200
250
300
400
500
600
700
800
0.001 0.003 0.004 0.006 0.010 0.016 0.022 0.031 0.040
0.012 0.021 0.033 0.048 0.085 0.133 0.192 0.261 0.341
563
633
707
741
774
827
849
891
999
1002
1017
1074
1145
1152
1221
1257
1295
1440
11
1446
11
1515
11
1568
11
1601
11
1605
11
1736
12
1773
12
1949
12
2031
12
2133
13
2228
13
2325
13

750
14
844
15
942
15
988
15
1032
16
1102
16
1132
16
1188
16
1332
17
1336
17
1356
17
1432
17
1526
17
1536
17
1628
18
1676
18
1726
18
1920
18
1928
18
2020
18
2090
19
2134
19
2140
19
2314
19
2364
19
2598
20
2708
20
2844
20
2970
20
3100
20

938
20
1055
20
1178
21
1235
21
1290
21
1378
21
1415
22
1485
22
1665
22
1670
22
1695
22
1790
23
1908
23
1920
23
2035
23
2095
23
2158
23
2400
24
2410
24
2525
24
2613
24
2668
24
2675
24
2893
25
2955
25
3248
25
3385
25
3555
26
3713
26
3875
26

1125
24
1266
25
1413
25
1482
26
1548
26
1653
26
1698
26
1782
26
1998
27
2004
27
2034
27
2148
27
2289
28
2304
28
2442
28
2514
28
2589
28
2880
29
2892
29
3030
29
3135
29
3201
29
3210
29
3471
29
3546
29
3897
30
4062
30
4266
30
4455
30
4650
31

1500
32
1688
32
1884
33
1976
33
2064
33
2204
33
2264
34
2376
34
2664
34
2672
34
2712
34
2864
35
3052
35
3072
35
3256
35
3352
35
3452
35
3840
36
3856
36
4040
36
4180
36
4268
36
4280
36
4628
37
4728
37
5196
37
5416
37
5688
38
5940
38
6200
38

1875
37
2110
38
2355
38
2470
39
2580
39
2755
39
2830
39
2970
39
3330
40
3340
40
3390
40
3580
40
3815
41
3840
41
4070
41
4190
41
4315
41
4800
42
4820
42
5050
42
5225
42
5335
42
5350
42
5785
42
5910
42
6495
43
6770
43
7110
43
7425
43
7750
44

2250
42
2532
43
2826
43
2964
43
3096
43
3306
44
3396
44
3564
44
3996
45
4008
45
4068
45
4296
45
4578
45
4608
45
4884
45
5028
46
5178
46
5760
46
5784
46
6060
46
6270
47
6402
47
6420
47
6942
47
7092
47
7794
47
8124
48
8532
48
8910
48
9300
48

2625
46
2954
47
3297
47
3458
47
3612
47
3857
48
3962
48
4158
48
4662
49
4676
49
4746
49
5012
49
5341
49
5376
49
5698
49
5866
50
6041
50
6720
50
6748
50
7070
50
7315
50
7469
51
7490
51
8099
51
8274
51
9093
51
9478
52
9954
52
10395
52
10850
52

3000
49
3376
50
3768
50
3952
51
4128
51
4408
51
4528
51
4752
51
5328
52
5344
52
5424
52
5728
52
6104
52
6144
53
6512
53
6704
53
6904
53
7680
53
7712
54
8080
54
8360
54
8536
54
8560
54
9256
54
9456
54
10392
55
10832
55
11376
55
11880
55
12400
56

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

AeroBlade Grilles

PERFORMANCE DATA

NC-10 NC-20

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC-40

NC-50

300
400
500
600
700
800
900
1000 1100
0.006 0.010 0.016 0.022 0.031 0.040 0.051 0.062 0.075
0.023 0.041 0.064 0.092 0.126 0.164 0.208 0.257 0.311
57
78
102
111
123
144
171
177
189
216
231
264
333
366
405
411
447
477
486
546
621
642
687
738
771
825
933
942
966
1029
1050
-

76
104
136
148
164
192
228
236
252
288
308
352
444
11
488
11
540
12
548
12
596
12
636
12
648
12
728
13
828
13
856
14
916
14
984
14
1028
14
1100
15
1244
15
1256
15
1288
15
1372
16
1400
16

95
13
130
14
170
15
185
16
205
16
240
17
285
17
295
18
315
18
360
19
385
19
440
19
555
20
610
21
675
21
685
21
745
22
795
22
810
22
910
23
1035
23
1070
23
1145
24
1230
24
1285
24
1375
24
1555
25
1570
25
1610
25
1715
25
1750
25

114
21
156
22
204
23
222
23
246
24
288
25
342
25
354
26
378
26
432
26
462
27
528
27
666
28
732
29
810
29
822
29
894
30
954
30
972
30
1092
30
1242
31
1284
31
1374
31
1476
32
1542
32
1650
32
1866
33
1884
33
1932
33
2058
33
2100
33

133
27
182
29
238
30
259
30
287
31
336
31
399
32
413
32
441
32
504
33
539
33
616
34
777
35
854
35
945
36
959
36
1043
36
1113
36
1134
37
1274
37
1449
38
1498
38
1603
38
1722
38
1799
39
1925
39
2177
39
2198
39
2254
40
2401
40
2450
40

152
33
208
34
272
36
296
36
328
36
384
37
456
38
472
38
504
38
576
39
616
39
704
40
888
41
976
41
1080
42
1096
42
1192
42
1272
42
1296
42
1456
43
1656
43
1712
44
1832
44
1968
44
2056
44
2200
45
2488
45
2512
45
2576
45
2744
46
2800
46

171
38
234
40
306
41
333
41
369
41
432
42
513
43
531
43
567
43
648
44
693
44
792
45
999
46
1098
46
1215
47
1233
47
1341
47
1431
47
1458
47
1638
48
1863
49
1926
49
2061
49
2214
49
2313
49
2475
50
2799
50
2826
50
2898
50
3087
51
3150
51

190
43
260
44
340
45
370
46
410
46
480
47
570
47
590
48
630
48
720
48
770
49
880
49
1110
50
1220
51
1350
51
1370
51
1490
52
1590
52
1620
52
1820
53
2070
53
2140
53
2290
54
2460
54
2570
54
2750
54
3110
55
3140
55
3220
55
3430
55
3500
55

209
47
286
48
374
49
407
50
451
50
528
51
627
52
649
52
693
52
792
53
847
53
968
53
1221
54
1342
55
1485
55
1507
55
1639
56
1749
56
1782
56
2002
57
2277
57
2354
57
2519
58
2706
58
2827
58
3025
58
3421
59
3454
59
3542
59
3773
59
3850
59

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

Nominal Nominal Core


Core Velocity
Duct
Duct
Area
Velocity Pressure
Size
Area
( ft2 ) Neg. Static Pressure
( in. )
( ft2 )
6x6
0.25
0.19
Airflow, cfm
NC
8x6
0.33
0.26
Airflow, cfm
NC
10x6
0.42
0.34
Airflow, cfm
NC
8x8
0.44
0.37
Airflow, cfm
NC
12x6
0.50
0.41
Airflow, cfm
NC
14x6
0.58
0.48
Airflow, cfm
NC
16x6
Airflow, cfm
12x8
0.67
0.57
NC
Airflow, cfm
10x10
0.69
0.59
NC
Airflow, cfm
18x6
0.75
0.63
NC
20x6
Airflow, cfm
12x10
0.83
0.72
NC
Airflow, cfm
22x6
0.92
0.77
NC
24x6
Airflow, cfm
12x12
1.00
0.88
NC
30x6
Airflow, cfm
18x10
1.25
1.11
NC
Airflow, cfm
14x14
1.36
1.22
NC
36x6
Airflow, cfm
18x12
1.50
1.35
NC
Airflow, cfm
22x10
1.53
1.37
NC
30x8
Airflow, cfm
24x10
1.67
1.49
NC
42x6
Airflow, cfm
18x14
1.75
1.59
NC
16x16
1.78
1.62
Airflow, cfm
NC
24x12
2.00
1.82
Airflow, cfm
18x16
NC
18x18
2.25
2.07
Airflow, cfm
NC
24x14
2.33
2.14
Airflow, cfm
NC
30x12
2.50
2.29
Airflow, cfm
NC
24x16
2.67
2.46
Airflow, cfm
NC
20x20
2.78
2.57
Airflow, cfm
NC
36x12
3.00
2.75
Airflow, cfm
NC
30x16
3.33
3.11
Airflow, cfm
24x20
NC
Airflow, cfm
22x22
3.36
3.14
NC
42x12
Airflow, cfm
36x14
3.50
3.22
NC
Airflow, cfm
24x22
3.67
3.43
NC
Airflow, cfm
30x18
3.75
3.5
NC

NC-30

www.titus-hvac.com | www.titus-energysolutions.com

25R -INCH 30B DEFLECTION


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

G29

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

G30

25R -INCH 30B DEFLECTION (continued)


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-10 NC-20 NC-30 NC-40
Nominal Nominal Core
Core Velocity
300
400
500
600
700
Duct
Duct
Area
Velocity Pressure
0.006 0.010 0.016 0.022 0.031
Size
Area
( ft2 ) Neg. Static Pressure 0.023 0.041 0.064 0.092 0.126
( in. )
( ft2 )
48x12
Airflow, cfm
1125
1500
1875
2250
2625
24x24
4.00
3.75
NC
16
26
34
40
Airflow, cfm
1266
1688
2110
2532
2954
36x18
4.50
4.22
NC
17
26
34
41
36x20
Airflow, cfm
1413
1884
2355
2826
3297
30x24
5.00
4.71
NC
17
27
35
41
Airflow, cfm
1482
1976
2470
2964
3458
4.94
NC
17
27
35
41
42x18
5.25
Airflow, cfm
1548
2064
2580
3096
3612
28x28
5.44
5.16
NC
17
27
35
42
42x20
Airflow, cfm
1653
2204
2755
3306
3857
30x28
5.83
5.51
NC
18
27
35
42
48x18
Airflow, cfm
1698
2264
2830
3396
3962
36x24
6.00
5.66
NC
18
27
35
42
Airflow, cfm
1782
2376
2970
3564
4158
30x30
6.25
5.94
NC
18
28
36
42
42x24
Airflow, cfm
1998
2664
3330
3996
4662
36x28
7.00
6.66
NC
19
28
36
43
4676
Airflow, cfm
2004
2672
3340
4008
46x22
7.03
6.68
NC
19
28
36
43
Airflow, cfm
2034
2712
3390
4068
4746
32x32
7.11
6.78
NC
19
28
36
43
Airflow, cfm
2148
2864
3580
4296
5012
36x30
7.50
7.16
NC
19
28
36
43
48x24
Airflow, cfm
2289
3052
3815
4578
5341
36x32
8.00
7.63
NC
19
29
37
43
Airflow, cfm
2304
3072
3840
4608
5376
34x34
8.03
7.68
NC
19
29
37
43
Airflow, cfm
2442
3256
4070
4884
5698
19
36x34
8.50
8.14
NC
29
37
44
Airflow, cfm
2514
5028
5866
3352 4190
42x30
8.75
8.38
NC
20
29
37
44
Airflow, cfm
2589
3452 4315
5178
6041
29
36x36
9.00
8.63
NC
20
37
44
42x34
Airflow, cfm
2880
3840
6720
4800 5760
48x30
10.00
9.6
NC
20
30
38
44
Airflow, cfm
2892
3856
4820 5784
6748
38x38
10.03
9.64
NC
20
30
38
44
Airflow, cfm
3030
4040
5050 6060
7070
42x36
10.50
10.1
NC
20
30
38
45
Airflow, cfm
3135
4180
5225 6270
7315
46x34
10.86 10.45
NC
20
30
38
45
Airflow, cfm
3201
4268
5335 6402
7469
42x38
11.08 10.67
NC
21
30
38
45
Airflow, cfm
3210
4280
5350 6420
7490
40x40
11.11
10.7
NC
21
30
38
45
Airflow, cfm
3471
4628
5785 6942
8099
48x36
12.00 11.57
NC
21
31
38
45
Airflow, cfm
3546
4728
5910 7092
8274
42x42
12.25 11.82
NC
21
31
39
45
Airflow, cfm
3897
5196
6495 7794
9093
44x44
13.44 12.99
NC
21
31
39
46
Airflow, cfm
4062
5416
6770 8124
9478
48x42
14.00 13.54
NC
22
31
39
46
Airflow, cfm
4266
5688
7110 8532
9954
39
46x46
14.69 14.22
NC
22
31
46
Airflow, cfm
4455
5940
7425
8910 10395
48x46
15.33 14.85
NC
22
32
40
46
Airflow, cfm
4650
6200
7750
9300 10850
48x48
16.00 15.50
NC
22
32
40
46

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC-50

NC-60

800
900 1000 1100
0.040 0.051 0.062 0.075
0.164 0.208 0.257 0.311
3000
46
3376
47
3768
47
3952
47
4128
47
4408
48
4528
48
4752
48
5328
48
5344
49
5424
49
5728
49
6104
49
6144
49
6512
49
6704
49
6904
50
7680
50
7712
50
8080
50
8360
50
8536
51
8560
51
9256
51
9456
51
10392
51
10832
52
11376
52
11880
52
12400
52

3375
51
3798
52
4239
52
4446
52
4644
52
4959
53
5094
53
5346
53
5994
54
6012
54
6102
54
6444
54
6867
54
6912
54
7326
54
7542
55
7767
55
8640
55
8676
55
9090
55
9405
56
9603
56
9630
56
10413
56
10638
56
11691
56
12186
57
12798
57
13365
57
13950
57

3750
56
4220
56
4710
57
4940
57
5160
57
5510
57
5660
57
5940
58
6660
58
6680
58
6780
58
7160
58
7630
59
7680
59
8140
59
8380
59
8630
59
9600
60
9640
60
10100
60
10450
60
10670
60
10700
60
11570
61
11820
61
12990
61
13540
61
14220
61
14850
62
15500
62

4125
60
4642
60
5181
61
5434
61
5676
61
6061
61
6226
62
6534
62
7326
62
7348
62
7458
62
7876
63
8393
63
8448
63
8954
63
9218
63
9493
63
10560
64
10604
64
11110
64
11495
64
11737
64
11770
64
12727
65
13002
65
14289
65
14894
65
15642
66
16335
66
17050
66

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

AeroBlade Grilles

PERFORMANCE DATA

NC-20

NC-30

NC-40

PERFORMANCE DATA

Nominal Nominal Core


Core Velocity
100
200
300
400
500
600
700
800
900
Duct
Duct
Area
Velocity Pressure
0.001 0.002 0.06 0.010 0.016 0.022 0.031 0.040 0.050
2
Size
Area
( ft ) 3F Neg. Static Pressure 0.004 0.018 0.040 0.072 0.112 0.162 0.220 0.288 0.364
( in. )
( ft2 )
4F Neg. Static Pressure 0.003 0.012 0.028 0.050 0.078 0.112 0.153 0.200 0.253
6x6
0.25
0.19
Airflow, cfm
19
38
57
76
95
114
133
152
171
19
29
39
NC
12
24
32
36
8x6
0.33
0.26
Airflow, cfm
26
52
78
130
182
208
104
156
234
NC
13
20
26
30
34
37
40
10x6
0.42
0.34
Airflow, cfm
34
68
102
136
170
204
238
272
306
NC
14
21
27
31
35
38
41
148
185
222
259
296
333
8x8
0.44
0.37
Airflow, cfm
37
74
111
NC
15
22
27
32
35
39
41
12x6
0.50
0.41
Airflow, cfm
41
82
123
164
205
246
287
328
369
39
NC
15
22
28
32
36
42
14x6
0.58
0.48
Airflow, cfm
48
96
144
192
240
288
336
432
384
NC
16
23
28
33
36
40
43
16x6
Airflow, cfm
57
114
171
228
285
342
399
456
513
12x8
0.67
0.57
NC
16
24
29
33
37
40
43
Airflow, cfm
59
118
177
236
295
354
413
472
531
10x10
0.69
0.59
NC
17
24
29
34
37
41
44
Airflow, cfm
63
126
189
252
315
378
441
504
567
29
18x6
0.75
0.63
NC
17
24
34
38
41
44
20x6
Airflow, cfm
72
144
216
288
432
504
576
648
360
12x10
0.83
0.72
NC
17
25
30
34
38
42
44
Airflow, cfm
77
154
231
308
385
462
539
616
693
22x6
0.92
0.77
NC
18
25
30
35
39
42
45
24x6
Airflow, cfm
88
176
264
352
440
528
616
704
792
39
12x12
1.00
0.88
NC
18
25
31
35
42
45
30x6
Airflow, cfm
111
222
333
444
555
666
888
999
777
19
18x10
1.25
1.11
NC
26
32
36
40
43
46
Airflow, cfm
122
244
488
610
732
854
976
1098
366
14x14
1.36
1.22
NC
20
27
32
37
41
44
47
36x6
Airflow, cfm
135
270
405
540
675
810
945
1080
1215
18x12
1.50
1.35
NC
20
27
33
37
41
44
47
Airflow, cfm
137
274
411
548
685
822
959
1096
1233
22x10
1.53
1.37
NC
20
27
33
37
41
44
47
30x8
Airflow, cfm
149
298
447
596
745
894
1043
1192
1341
24x10
1.67
1.49
NC
11
21
28
33
38
41
45
48
42x6
Airflow, cfm
159
318
477
636
795
954
1113
1272
1431
18x14
1.75
1.59
NC
11
21
28
33
38
42
45
48
16x16
1.78
1.62
Airflow, cfm
162
324
486
648
810
972
1134
1296
1458
NC
11
21
28
34
38
42
45
48
24x12
2.00
1.82
Airflow, cfm
182
364
546
728
910
1092
1274
1456
1638
18x16
NC
12
22
29
34
38
42
46
48
1449
1656
1863
18x18
2.25
2.07
Airflow, cfm
207
414
621
828
1035 1242
NC
12
22
29
35
39
43
46
49
24x14
2.33
2.14
Airflow, cfm
214
428
642
856
1070 1284
1498
1712
1926
29
NC
12
22
35
39
43
46
49
30x12
2.50
2.29
Airflow, cfm
229
458
687
1145
1374
1603
1832
2061
916
39
49
NC
13
23
30
35
43
47
24x16
2.67
2.46
Airflow, cfm
246
492
738
984
1230
1722
1968
1476
2214
NC
13
23
30
35
40
44
47
50
20x20
2.78
2.57
Airflow, cfm
257
514
771
1028 1285
1542
1799
2056
2313
NC
13
23
30
36
40
44
47
50
36x12
3.00
2.75
Airflow, cfm
275
550
825
1100 1375
1650
1925
2200
2475
NC
13
23
30
36
40
44
47
50
30x16
3.33
3.11
Airflow, cfm
311
622
933
1244 1555
1866
2177
2488
2799
24x20
NC
14
24
31
36
41
45
48
51
Airflow, cfm
314
628
942
1256 1570
1884
2198
2512
2826
22x22
3.36
3.14
NC
14
24
31
36
41
45
48
51
42x12
Airflow, cfm
322
644
966
1288 1610
1932
2254
2576
2898
36x14
3.50
3.22
NC
14
24
31
37
41
45
48
51
Airflow, cfm
343
686
1029
1372 1715
2058
2401
2744
3087
24x22
3.67
3.43
NC
14
24
31
37
41
45
48
51
Airflow, cfm
350
700
1050
1400 1750
2100
2450
2800
3150
30x18
3.75
3.5
NC
14
24
31
37
41
45
48
51

www.titus-hvac.com | www.titus-energysolutions.com

3F, 4F 45B DEFLECTION


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

NC-50

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

G31

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

G32

3F, 4F 45B DEFLECTION (continued)


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-20 NC-30

NC-40

NC-50

Nominal Nominal Core


Core Velocity
100
200
300
400
500
600
700
800
900
Duct
Duct
Area
Velocity Pressure
0.001 0.002 0.06 0.010 0.016 0.022 0.031 0.040 0.050
Size
Area
( ft2 ) 3F Neg. Static Pressure 0.004 0.018 0.040 0.072 0.112 0.162 0.220 0.288 0.364
( in. )
( ft2 )
4F Neg. Static Pressure 0.003 0.012 0.028 0.050 0.078 0.112 0.153 0.200 0.253
48x12
Airflow, cfm
375
750
1125
1500 1875
2250
2625
3000
3375
24x24
4.00
3.75
NC
15
25
32
37
42
45
49
52
Airflow, cfm
422
844
1266
1688 2110
2532
2954
3376
3798
49
36x18
4.50
4.22
NC
15
25
32
38
42
46
52
36x20
Airflow, cfm
471
942
1413
1884 2355
2826 3297
3768 4239
30x24
5.00
4.71
NC
16
26
33
38
43
46
50
53
1976 2470
2964 3458
3952 4446
Airflow, cfm
494
988
1482
42x18
5.25
4.94
NC
16
26
33
38
43
47
50
53
Airflow, cfm
516
1032
1548
2064 2580
3096 3612
4128 4644
28x28
5.44
5.16
NC
16
26
33
39
43
47
50
53
42x20
Airflow, cfm
551
1102
1653
2204 2755
3306 3857
4408 4959
30x28
5.83
5.51
NC
16
26
33
39
43
47
50
53
48x18
Airflow, cfm
566
1132
1698
2264 2830
3396 3962
4528 5094
36x24
6.00
5.66
NC
17
26
33
39
43
47
50
53
Airflow, cfm
594
1188
1782
2376 2970
3564 4158
4752 5346
39
30x30
6.25
5.94
NC
17
27
34
44
47
51
54
42x24
Airflow, cfm
666
1332
1998
2664
3996
4662
5328 5994
3330
36x28
7.00
6.66
NC
17
27
34
40
44
48
51
54
Airflow, cfm
668
1336
2004
2672
3340
4008
4676
5344 6012
46x22
7.03
6.68
NC
17
27
34
40
44
48
51
54
Airflow, cfm
678
1356
2034
2712
3390
4068
4746
5424 6102
32x32
7.11
6.78
NC
17
27
34
40
44
48
51
54
Airflow, cfm
716
1432
2148
2864
3580
4296
5012
5728 6444
36x30
7.50
7.16
NC
18
27
35
40
44
48
51
54
48x24
Airflow, cfm
763
1526
2289
3052
3815
4578
5341
6104 6867
36x32
8.00
7.63
NC
18
28
35
40
45
48
52
55
Airflow, cfm
768
1536
2304
3072
3840
4608
5376
6144 6912
34x34
8.03
7.68
NC
18
28
35
40
45
49
52
55
Airflow, cfm
814
1628
2442
3256
4070
4884
5698
6512 7326
36x34
8.50
8.14
NC
18
28
35
41
45
49
52
55
Airflow, cfm
838
1676
2514
3352
4190
5028
5866
6704 7542
42x30
8.75
8.38
NC
18
28
35
41
45
49
52
55
Airflow, cfm
863
1726
2589
3452
4315
5178
6041
6904 7767
36x36
9.00
8.63
NC
18
28
35
41
45
49
52
55
42x34
Airflow, cfm
960
1920
2880
3840
4800
5760
6720
7680 8640
49
48x30
10.00
9.6
NC
19
29
36
41
46
53
56
Airflow, cfm
964
1928
2892
3856
4820 5784
7712
8676
6748
38x38
10.03
9.64
NC
19
29
36
41
46
50
53
56
Airflow, cfm
1010 2020
3030
4040
5050 6060
7070
8080
9090
42x36
10.50
10.1
NC
19
29
36
41
46
50
53
56
Airflow, cfm
1045 2090
3135
4180
5225 6270
7315
8360
9405
46x34
10.86 10.45
NC
19
29
36
42
46
50
53
56
Airflow, cfm
1067 2134
3201
4268
5335 6402
7469
8536
9603
42x38
11.08 10.67
NC
19
29
36
42
46
50
53
56
Airflow, cfm
1070 2140
3210
4280
5350 6420
7490
8560
9630
19
29
40x40
11.11
10.7
NC
36
42
46
50
53
56
Airflow, cfm
1157
5785 6942
8099
9256 10413
2314
3471 4628
48x36
12.00 11.57
NC
20
30
37
42
47
50
54
56
Airflow, cfm
1182
2364
3546 4728
5910 7092
8274
9456 10638
42x42
12.25 11.82
NC
20
30
37
42
47
50
54
57
Airflow, cfm
1299
2598
3897 5196
6495 7794
9093 10392 11691
44x44
13.44 12.99
NC
20
30
37
43
47
51
54
57
9478 10832 12186
Airflow, cfm
1354
2708
4062 5416
6770 8124
48x42
14.00 13.54
NC
20
30
37
43
47
51
54
57
Airflow, cfm
1422
2844
4266 5688
7110 8532
9954 11376 12798
46x46
14.69 14.22
NC
21
30
37
43
47
51
54
57
Airflow, cfm
1485
2970
4455 5940
7425 8910 10395 11880 13365
48x46
15.33 14.85
NC
21
31
38
43
48
51
55
58
Airflow, cfm
1550
3100
4650 6200
7750 9300 10850 12400 13950
48x48
16.00 15.50
NC
21
31
38
43
48
52
55
58

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

AeroBlade Grilles

PERFORMANCE DATA

NC-10

NC-20

NC-30

NC-40

PERFORMANCE DATA

Nominal Nominal Core


Core Velocity
300
400
500
600
700
800 1000 1200 1400
Duct
Duct
Area
Velocity Pressure
0.006 0.010 0.016 0.022 0.031 0.040 0.062 0.090 0.122
2
Size
Area
( ft ) Neg. Static Pressure 0.013 0.023 0.036 0.052 0.071 0.094 0.144 0.208 0.283
( in. )
( ft2 )
6x6
0.25
0.19
Airflow, cfm
57
76
95
114
133
152
190
228
266
18
28
NC
14
22
34
38
8x6
0.33
0.26
Airflow, cfm
78
104
130
156
208
312
364
182
260
39
NC
16
20
24
30
35
10x6
0.42
0.34
Airflow, cfm
102
136
204
238
272
340
408
170
476
NC
12
17
21
25
31
36
40
8x8
0.44
0.37
Airflow, cfm
111
148
185
222
259
296
370
444
518
12
17
21
25
31
36
41
NC
12x6
0.50
0.41
Airflow, cfm
123
164
205
246
287
328
410
492
574
NC
12
18
22
26
32
37
41
14x6
0.58
0.48
Airflow, cfm
144
192
240
288
336
384
480
576
672
NC
13
18
22
26
32
38
42
16x6
Airflow, cfm
171
228
285
342
399
456
570
684
798
12x8
0.67
0.57
NC
14
19
23
27
33
38
43
Airflow, cfm
177
236
295
354
413
472
590
708
826
10x10
0.69
0.59
NC
14
19
23
27
33
38
43
Airflow, cfm
189
252
315
378
441
504
630
756
882
19
18x6
0.75
0.63
NC
14
24
27
34
39
43
20x6
Airflow, cfm
216
288
360
504
576
720
864
1008
432
39
12x10
0.83
0.72
NC
15
20
24
28
34
44
Airflow, cfm
231
308
385
462
539
616
770
1078
924
22x6
0.92
0.77
NC
15
20
25
28
35
40
44
24x6
Airflow, cfm
264
352
440
528
616
704
880
1056 1232
29
12x12
1.00
0.88
NC
16
21
25
35
40
45
30x6
Airflow, cfm
333
444
555
666
777
1110
1332 1554
888
18x10
1.25
1.11
NC
17
22
26
30
36
41
46
Airflow, cfm
366
610
732
854
976
1220
1464 1708
488
14x14
1.36
1.22
NC
11
17
22
27
30
37
42
46
36x6
Airflow, cfm
405
540
675
810
945
1080 1350
1620 1890
18x12
1.50
1.35
NC
11
18
23
27
31
37
42
46
685
822
959
1096 1370
1644 1918
Airflow, cfm
411
548
22x10
1.53
1.37
NC
11
18
23
27
31
37
42
46
30x8
Airflow, cfm
447
596
745
894
1043
1192 1490
1788 2086
24x10
1.67
1.49
NC
12
18
23
27
31
37
42
47
42x6
Airflow, cfm
477
636
795
954
1113
1272 1590
1908 2226
18x14
1.75
1.59
NC
12
18
23
28
31
38
43
47
16x16
1.78
1.62
Airflow, cfm
486
648
810
972
1134
1296 1620
1944 2268
NC
12
18
23
28
32
38
43
47
24x12
2.00
1.82
Airflow, cfm
546
728
910
1092 1274
1456 1820
2184 2548
18x16
NC
13
19
24
28
32
38
43
48
18x18
2.25
2.07
Airflow, cfm
621
828
1035
1242 1449
1656 2070
2484 2898
19
NC
13
25
29
33
39
44
48
24x14
2.33
2.14
Airflow, cfm
642
856
1284
1498
1712 2140
2568 2996
1070
NC
13
20
25
29
33
39
44
48
30x12
2.50
2.29
Airflow, cfm
687
916
1145
1374
1603
1832 2290
2748 3206
29
39
NC
14
20
25
33
44
49
24x16
2.67
2.46
Airflow, cfm
738
984
1230 1476
2952
3444
1722 1968
2460
NC
14
20
25
30
33
40
45
49
20x20
2.78
2.57
Airflow, cfm
771
1028
1285 1542
1799 2056
2570
3084
3598
NC
14
20
25
30
34
40
45
49
36x12
3.00
2.75
Airflow, cfm
825
1100
1375 1650
1925 2200
2750
3300
3850
49
NC
14
21
26
30
34
40
45
30x16
3.33
3.11
Airflow, cfm
933
1244
1555 1866
2177 2488
3110 3732
4354
24x20
NC
15
21
26
31
34
41
46
50
Airflow, cfm
942
1256
1570 1884
2198 2512
3140 3768
4396
22x22
3.36
3.14
NC
15
21
26
31
34
41
46
50
42x12
Airflow, cfm
966
1288
1610 1932
2254 2576
3220 3864
4508
36x14
3.50
3.22
NC
15
21
26
34
34
41
46
50
Airflow, cfm
1029
1372
1715 2058
2401 2744
3430 4116
4802
24x22
3.67
3.43
NC
15
22
27
31
35
41
46
50
Airflow, cfm
1050
1400
1750 2100
2450 2800
3500 4200
4900
30x18
3.75
3.5
NC
15
22
27
31
35
41
46
51

www.titus-hvac.com | www.titus-energysolutions.com

55F, 56F 0B DEFLECTION


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

NC-50

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

G33

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

G34

55F, 56F 0B DEFLECTION (continued)


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-10

NC20

NC-30

Nominal Nominal Core


Core Velocity
300
400
500
600
700
Duct
Duct
Area
Velocity Pressure
0.006 0.010 0.016 0.022 0.031
2
Size
Area
( ft ) Neg. Static Pressure 0.013 0.023 0.036 0.052 0.071
( in. )
( ft2 )
48x12
Airflow, cfm
1125
1500
1875 2250
2625
24x24
4.00
3.75
NC
16
22
27
31
Airflow, cfm
1266
1688
2110 2532
2954
36x18
4.50
4.22
NC
16
23
28
32
36x20
Airflow, cfm
1413
1884
2355 2826
3297
30x24
5.00
4.71
NC
17
23
28
32
Airflow, cfm
1482
1976
2470 2964
3458
NC
17
23
28
33
42x18
5.25
4.94
Airflow, cfm
1548
2064
2580 3096
3612
28x28
5.44
5.16
NC
17
23
28
33
42x20
Airflow, cfm
1653
2204
2755 3306
3857
30x28
5.83
5.51
NC
17
24
29
33
48x18
Airflow, cfm
1698
2264
2830 3396
3962
36x24
6.00
5.66
NC
18
24
29
33
Airflow, cfm
1782
2376
2970 3564
4158
29
30x30
6.25
5.94
NC
18
24
33
42x24
Airflow, cfm
1998
2664
3330
4662
3996
36x28
7.00
6.66
NC
18
25
30
34
Airflow, cfm
2004
2672
3340
4008
4676
46x22
7.03
6.68
NC
18
25
30
34
Airflow, cfm
2034
2712
3390
4068
4746
32x32
7.11
6.78
NC
18
25
30
34
Airflow, cfm
2148
2864
3580
4296
5012
36x30
7.50
7.16
NC
11
19
25
30
34
48x24
Airflow, cfm
2289
3052
3815
4578
5341
36x32
8.00
7.63
NC
11
19
25
30
35
Airflow, cfm
2304
3072
3840
4608
5376
11
34x34
8.03
7.68
NC
19
25
30
35
Airflow, cfm
4070
4884
5698
2442 3256
36x34
8.50
8.14
NC
11
19
25
30
35
2514 3352
4190
5028
5866
Airflow, cfm
42x30
8.75
8.38
NC
11
19
26
31
35
Airflow, cfm
2589 3452
4315
5178
6041
19
36x36
9.00
8.63
NC
11
26
31
35
42x34
Airflow, cfm
2880
5760
6720
3840 4800
48x30
10.00
9.6
NC
12
20
26
31
36
Airflow, cfm
2892
3856 4820
5784
6748
38x38
10.03
9.64
NC
12
20
26
31
36
Airflow, cfm
3030
4040 5050
6060
7070
42x36
10.50
10.1
NC
12
20
26
31
36
Airflow, cfm
3135
4180 5225
6270 7315
46x34
10.86 10.45
NC
12
20
26
32
36
Airflow, cfm
3201
4268 5335
6402 7469
42x38
11.08 10.67
NC
12
20
27
32
36
Airflow, cfm
3210
4280 5350
6420 7490
40x40
11.11
10.7
NC
12
20
27
32
36
Airflow, cfm
3471
4628 5785
6942 8099
48x36
12.00 11.57
NC
13
21
27
32
36
Airflow, cfm
3546
4728 5910
7092 8274
42x42
12.25 11.82
NC
13
21
27
32
36
Airflow, cfm
3897
5196 6495
7794 9093
44x44
13.44 12.99
NC
13
21
27
33
37
Airflow, cfm
4062
5416 6770
8124 9478
48x42
14.00 13.54
NC
13
21
28
33
37
Airflow, cfm
4266
5688 7110
8532 9954
46x46
14.69 14.22
NC
14
22
28
33
37
Airflow, cfm
4455
5940 7425
8910 10395
48x46
15.33 14.85
NC
14
22
28
33
37
Airflow, cfm
4650
6200 7750
9300 10850
48x48
16.00 15.50
NC
14
22
28
33
38

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC-40

NC-50

800
1000 1200 1400
0.040 0.062 0.090 0.122
0.094 0.144 0.208 0.283
3000
35
3376
36
3768
36
3952
36
4128
37
4408
37
4528
37
4752
37
5328
38
5344
38
5424
38
5728
38
6104
38
6144
38
6512
39
6704
39
6904
39
7680
39
7712
39
8080
39
8360
40
8536
40
8560
40
9256
40
9456
40
10392
41
10832
41
11376
41
11880
41
12400
41

3750
41
4220
42
4710
42
4940
43
5160
43
5510
43
5660
43
5940
43
6660
44
6680
44
6780
44
7160
44
7630
44
7680
45
8140
45
8380
45
8630
45
9600
45
9640
46
10100
46
10450
46
10670
46
10700
46
11570
46
11820
46
12990
47
13540
47
14220
47
14850
47
15500
48

4500
47
5064
47
5652
47
5928
48
6192
48
6612
48
6792
48
7128
49
7992
49
8016
49
8136
49
8592
49
9156
50
9216
50
9768
50
10056
50
10356
50
11520
51
11568
51
12120
51
12540
51
12804
51
12840
51
13884
51
14184
51
15588
52
16248
52
17064
52
17820
52
18600
53

5250
51
5908
51
6594
52
6916
52
7224
52
7714
52
7924
53
8316
53
9324
53
9352
53
9492
53
10024
54
10682
54
10752
54
11396
54
11732
54
12082
54
13440
55
13496
55
14140
55
14630
55
14938
55
14980
55
16198
56
16548
56
18186
56
18956
56
19908
57
20790
57
21700
57

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

AeroBlade Grilles

SUGGESTED SPECIFICATIONS

Available Models:
23RL/23RS
25RL/25RS

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel. Damper must be operable from the
face of the grille.

Available Narrow Tee Models:


23RL-NT/23RS-NT
25RL-NT/25RS-NT

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315F for 30 minutes.
The pencil hardness must be HB to H. The paint must
pass a 100-hour ASTM B117 Corrosive Environments Salt
Spray Test without creepage, blistering or deterioration of
film. The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.

Steel return grilles shall be Titus AeroBlade Series Model


23R (-inch blade spacing) or 25R (-inch blade spacing)
for the sizes and mounting types as shown on the plans
and outlet schedule (add -NT for narrow tee). The fixed
deflection blades shall be available parallel to the long or
short dimension of the grille. Construction shall be of steel
with a 1-inch wide border on all sides and a minimum
border gauge of 20. Corners shall be assembled with full
penetration resistance welds with a reinforcing patch for
extra strength.

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

Blades shall be accurately formed to a proven curvature that


has been certified according to current industry standards in
a certified laboratory. Blades shall have a minimum gauge

For Narrow Tee Models add: Grilles shall be compatible


with 24 x 24-inch modules for regressed narrow tee ceiling
systems.

MODEL NUMBER SPECIFICATION


AEROBLADE STANDARD RETURN GRILLES

Model
23
25

45 Deflection, Spacing

Narrow
Tee

30 Deflection, Spacing

NT

XX

Material

Width

Module Size

Height

Steel

Front Blade
Orientation

Aluminum
Colored
Paint

(Use only for border


types 2, 3 and 4.)

-XX

S
L

White (std.)

XX

Border Type

Parallel to Short Dim.

Surface Mount

Parallel to Long Dim.

Snap-In
Lay-In
Spline

Finish
26
01

www.titus-hvac.com | www.titus-energysolutions.com

of 20 with a fixed deflection angle of 45 (23RL and 23RS)


or 30 (Models 25RL and 25RS).

AEROBLADE RETURN GRILLES - STEEL

Optional
PFAP

Aluminum
Plaster Frame

XX-XX

XXXX

Steel
AG-35
Optional Damper

1
2
3
4

AEROBLADE FILTER RETURN GRILLES

45 Deflection, Spacing
30 Deflection, Spacing

XXX
Material

Steel

1 Filter
Frame

Filter Frame

Front Blade Orientation


Parallel to Short Dim.
S
Parallel to Long Dim.
L
X

Border Type
Surface Mount
1
X
White (std.)

Width

Height

Aluminum
Colored Paint

X
26
01

SPECIFICATIONS

Model
23
25

Finish
Note: For specification information, use AeroBlade Steel Return Grilles specifications
within this catalog section and specify a 1-inch filter frame.

G35

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

Blades shall be firmly held in place by mullions from behind


the grille and fixed in place by crimping or welding. Blade
shall have a fixed deflection angle of 0 (Model 55FL, 55FS,
56FL or 56FS) and 45 (Models 3FL, 3FS, 4FL and 4FS).

AEROBLADE RETURN GRILLES - ALUMINUM


Available Models:
3FL/3FS
56FL/56FS
4FL/4FS
55FL/55FS

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel or aluminum. Damper must be
operable from the face of the grille.

Available Narrow Tee Models:


3FL-NT/3FS-NT
56FL-NT/56FS-NT
4FL-NT/4FS-NT
55FL-NT/55FS-NT

The grille finish shall be #26 white. The finish shall be


an anodic acrylic paint, baked at 315F for 30 minutes.
The pencil hardness must be HB to H. The paint must
pass a 100-hour ASTM B117 Corrosive Environments Salt
Spray Test without creepage, blistering or deterioration of
film. The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.

Aluminum return grilles shall be Titus AeroBlade Series


Model 3F or 56F (-inch blade spacing) or 4F or 55F
(-inch blade spacing). The fixed deflection blades shall be
available parallel to the long or short dimension of the grille.
Construction shall be of extruded aluminum with a 1inch wide border on all sides and shall be interlocked at the
four corners and mechanically staked to form a rigid frame.
Minimum border thickness shall be 0.040 to 0.050 inch.
Screw holes shall be countersunk for a neat appearance.

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.
For Narrow Tee Models add: Grilles shall be compatible
with 24 x 24-inch modules for regressed narrow tee ceiling
systems.

Blades shall be contoured to a specifically designed and


tested cross-section to meet published performance data.

MODEL NUMBER SPECIFICATION


AEROBLADE STANDARD RETURN GRILLES
Model
3
56
4
55

45 Deflection, Spacing
0 Deflection, Spacing
45 Deflection, Spacing
0 Deflection, Spacing

XXX

Material

Narrow
Tee
NT

Width

-XX

(Use only for border


types 2, 3 and 4.)

Height

Aluminum

Front Blade
Orientation

Module Size

S
L

White (std.)
Aluminum
Colored Paint

Border Type

Parallel to Short Dim.

Surface Mount

Parallel to Long Dim.

Snap-In
Lay-In
Spline

XX

SPECIFICATIONS

45 Deflection, Spacing
0 Deflection, Spacing
45 Deflection, Spacing
0 Deflection, Spacing

XXX
Material

Steel

1 Filter
Frame

Filter Frame

G36

Front Blade Orientation


Parallel to Short Dim.
S
Parallel to Long Dim.
L
X

Border Type
Surface Mount
1
X

X
White (std.)

Width

Height

Aluminum
Colored Paint

Note: For specification information, use AeroBlade Aluminum Return Grilles


specifications within this catalog section and specify a 1-inch filter frame.

Optional
PFA

Aluminum
Plaster Frame

XX-XX

Steel AG-35
Optional Damper

1
2
3
4

AEROBLADE FILTER RETURN GRILLES


Model
3
56
4
55

Finish
26
01

X
26
01
Finish

XXXX

AeroBlade Grilles

Options and Accessories


Model
#
271
272
271
272
111
112
121
122
131
132

Type
Grille
Stl-Supply
Stl-Supply
Al-Supply
Al-Supply
Stl-Supply
Stl-Supply
Stl-Supply
Stl-Supply
Stl-Supply
Stl-Supply

Deflection
Degrees
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable

Blade Border
Spacing Type OS FR #01 #04 #20 #21 #26 #34 #84 #94 #95 #96

1
Y
Y
Y
Y
Y
Y
Y N Y N N N

1
Y
Y
Y
Y
Y
Y
Y N Y N N N

1
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

1
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
1
1
Y
Y
Y
Y
Y
Y
Y N Y N N N
1
1
Y
Y
Y
Y
Y
Y
Y N Y N N N
2
1
Y
Y
Y
Y
Y
Y
Y N Y N N N
2
1
Y
Y
Y
Y
Y
Y
Y N Y N N N
3
1
Y
Y
Y
Y
Y
Y
Y N Y N N N
3
1
Y
Y
Y
Y
Y
Y
Y N Y N N N

DS

IS

FG

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

Model
Type
Type
#
Grille
Deflection
3
Al-Return
Fixed
3
Al-Return
Fixed
3
Al-Return
Fixed
3
Al-Return
Fixed
3
Al-Return
Fixed
3FF
Al-Filter Return
Fixed
3FF
Al-Filter Return
Fixed
4
Al-Return
Fixed
4
Al-Return
Fixed
4
Al-Return
Fixed
4
Al-Return
Fixed
4
Al-Return
Fixed
4FF
Al-Filter Return
Fixed
4FF
Al-Filter Return
Fixed
23
Stl-Return
Fixed
23
Stl-Return
Fixed
23
Stl-Return
Fixed
23
Stl-Return
Fixed
23
Stl-Return
Fixed
23RF Stl. Filter Return
Fixed
25
Stl-Return
Fixed
25
Stl-Return
Fixed
25
Stl-Return
Fixed
25
Stl-Return
Fixed
25
Stl-Return
Fixed
25RF Stl. Filter Return
Fixed
55
Al-Return
Fixed
55
Al-Return
Fixed
55
Al-Return
Fixed
55
Al-Return
Fixed
55
Al-Return
Fixed
55FF Al-Filter Return
Fixed
55FF Al-Filter Return
Fixed
56
Al-Return
Fixed
56
Al-Return
Fixed
56
Al-Return
Fixed
56
Al-Return
Fixed
56
Al-Return
Fixed
56FF Al-Filter Return
Fixed
56FF Al-Filter Return
Fixed

Deflection
Degrees
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
30
30
30
30
30
30
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Blade Border
Spacing Type OS FR #01 #04 #20 #21 #26 #34 #84 #94 #95 #96

1
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

2
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

3
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

4
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

7
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

1
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

3
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

1
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

2
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

3
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

4
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

7
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

1
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

3
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

1
Y
Y
Y
Y
Y
Y
Y N Y N N N

2
N N Y
Y
Y
Y
Y N Y N N N

3
N N Y
Y
Y
Y
Y N Y N N N

4
N N Y
Y
Y
Y
Y N Y N N N

7
N N Y
Y
Y
Y
Y N Y N N N

1
N N Y
Y
Y
Y
Y N Y N N N

1
Y
Y
Y
Y
Y
Y
Y N Y N N N

2
N N Y
Y
Y
Y
Y N Y N N N

3
N N Y
Y
Y
Y
Y N Y N N N

4
N N Y
Y
Y
Y
Y N Y N N N

7
N N Y
Y
Y
Y
Y N Y N N N

1
N N Y
Y
Y
Y
Y N Y N N N

1
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

2
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

3
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

4
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

7
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

1
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

3
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

1
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

2
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

3
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

4
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

7
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

1
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

3
N N Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

DS

IS

FG

Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Y
N
N
N
N
N
N
Y
N
N
N
N
N
N

Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
N
N

Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
N
N

Y
N
N
N
N
N
N
Y
N
N
N
N
N
N
Y
N
N
N
N
N
Y
N
N
N
N
N
Y
N
N
N
N
N
N
Y
N
N
N
N
N
N

PFA EQT
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

RETURN OPTIONS

Caution: All options are not available in all combinations. Check with your Titus representative for details.
Titus reserves the right to discontinue or add options at any time without notice.

SERIES FINISHES - OPTIONS AND ACCESSORIES


FINISHES:










#01 Aluminum Colored Paint


#04 Mill Finish
#20 Envirotherm Color To Match Sample*
#21 Envirothane Color To Match Sample*
#25 Off White*
#26 White (standard on most models)
#34 Clear Anodized*
#84 Black*
#94 Light Bronze Anodized*
#95 Medium Bronze Anodized*
#96 Dark Bronze Anodized*

Note: An asterisk (*) indicates additional cost.

OPTIONS AND ACCESSORIES:



OS

FR

C

DS


IS


FG

PFA

EQT

Oversize
Fractional Size
Concealed Fasteners
Debris Screen Square Mesh
Galvanized Steel Screen
Insect Screen 1/16 Square Mesh
Galvanized Steel Screen
Foam Gasket On Back Side of Border
Aluminum Plaster Frame
Earthquake Tab For Safety Wiring
to Support Structure

PFA EQT
Y
N
N
N
N
N
N
Y
N
N
N
N
N
N
Y
N
N
N
N
N
Y
N
N
N
N
N
Y
N
N
N
N
N
N
Y
N
N
N
N
N
N

Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
N
N

OPTIONS & ACCESSORIES

Type
Deflection
Single
Double
Single
Double
Single
Double
Single
Double
Single
Double

www.titus-hvac.com | www.titus-energysolutions.com

SUPPLY OPTIONS

G37

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

Options and Accessories (continued)

BORDER TYPES

Snap-In

BORDER TYPE 2
SNAP-IN (PANEL MOUNTED)

Available Module Sizes


12 x 12 inches
24 x 12 inches
36 x 12 inches
48 x 12 inches
24 x 24 inches
36 x 24 inches
48 x 24 inches

BORDER TYPE 3
LAY-IN (PANEL MOUNTED)

Available Module Sizes


12 x 12 inches
24 x 12 inches
36 x 12 inches
48 x 12 inches
24 x 24 inches
36 x 24 inches
48 x 24 inches

13/16"

Ceiling Module Size


minus 1/16"
Note: Maximum grille area is module size minus 4 inches.
Lay-In (Panel Mounted)

Note: Filter grilles not available in all


module sizes.

BORDER TYPE 4
SPLINE (PANEL MOUNTED)

Available Module Sizes


12 x 12 inches
24 x 12 inches
36 x 12 inches
48 x 12 inches
24 x 24 inches
36 x 24 inches
48 x 24 inches

Ceiling Module Size


minus "

Note: Maximum grille area is module size minus 4 inches.


Spline (Panel Mounted)

BORDER TYPE NT
NARROW TEE (PANEL MOUNTED)

3/8"

Available Module Sizes


24 x 12 inches
24 x 24 inches

3/8"

Ceiling Module Size


minus "

Note: Maximum grille area is module size minus 4 inches.

ACCESSORIES

OPTIONS & ACCESSORIES

TYPE A FASTENING SURFACE


MOUNT

NARROW TEE

Narrow Tee

Standard For All Border Type


1 Surface Mount Grilles.
Note: For screw hole locations
see the chart, Screw
Hole Location Chart.

TYPE C FASTENING CONCEALED


MOUNTING

Available on Most Models


with Border Type 1.
Note: Not available on sizes
larger than 36 x 36 inches. Not
available on modules with -inch
blade spacing and other than 0
deflection. Not recommended with
return grilles with 45 deflection
and -inch blade spacing.
Concealed mounting is not
available with damper.

16 "
5

16 "

Ceiling Module Minus 3/4"

Note: Maximum grille size is 48 x 48 inches.


Type A - External Screw

Type C - Concealed Screw


Duct Size
minus "

"

1"
Duct
Duct Size

G38

AeroBlade Grilles

Oversize Grille Construction


For ducts or openings larger than 48 inches.

Joining With Aluminum Mullions


Detail #1. Partial Face View
Standard 1" Border
A

Std Ctr sk
Screw Holes

Detail #1 (Typ.)

X
D

Section X-X

11/16"

"

www.titus-hvac.com | www.titus-energysolutions.com

AEROBLADE SERIES

Supply or
Return Grille
E
Extruded Aluminum
Joiner Mullion
Detail #2 (Typ.)
Detail #2. Partial Face View

Std Ctr sk
Screw Holes

Detail #1 (Typ.)
H
Section Y-Y
5/16"

Overall Duct or Opening Dimension D Parallel to Blades


6-48

49-96

97-144

145-192

193-240

6-48

A (1)

B (2)

C (3)

D (4)

E (5)

49-96

F (2)

G (4)

NA

NA

NA

97-144

H (3)

NA

NA

NA

NA

"
2"
Continuous Aluminum Extrusion

Notes:
Letters A through H refer to arrangement diagrams above.
Numbers in parentheses denote number of sections.
For sizes larger than shown, contact factory for details.
Does not apply to filter grilles.
Joiner mullions are shipped loose for field installation.
Titus recommends additional structural support behind grille for diagrams C, D, E, G and H.

OVERSIZE GRILLE CONSTRUCTION

D Across
Blades

G39

AeroBlade Grilles

www.titus-hvac.com | www.titus-energysolutions.com

Screw Hole Location Chart


For use with AeroBlade Series Grilles
up to 48 x 48 inches (not for use with
filter grilles)

Screw Layout Diagrams 1 - 14


EQ
.
EQ
.

How to use these charts


1. Determine desired grille size.
2. Find the grille size in Grille
Size Chart.
3. Use the Grille Size Chart to select
the proper diagram number, 1
through 14, and determine the
location style of screw holes for
grilles. The number corresponds
to the diagrams in the Screw Hole
Layout Diagrams 1-14.
4. Determine screw hole location
dimension using Table A.
5. Determine the required number of
screws using Table B.

EQ
.
EQ
.

10

11

EQ
. EQ
.

B
9

A
B

B
A
A

13

12

B
B

1"

B
/16"

A
14

A
A
B

Table A

Grille Size Chart

G40

Short Side

SCREW HOLE LOCATION

Duct
Size
4
5
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48

Screw Hole Location


Long Side
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

10

11

12

13

14

Note: This chart provides general information concerning location of screw holes. Screw hole
location subject to change without notice. Titus does not recommend predrilling mounting
surfaces for screws. Use the grille as a template.
All dimensions are in inches.

Duct Size

Dim. A

16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48

10
12
14
16
9
10
11
12
13
14
15
11
11
12
13
13
14

Table B
Location
No. of
Style
Screws
1
2
2
4
3
6
4
8
5
4
6
6
7
8
8
10
9
8
10
10
11
12
12
12
13
14
14
16

Dim. B

1 Border

319/32
319/32
319/32
319/32
311/32
311/32
311/32
311/32
311/32
311/32
311/32
311/32
319/32
327/32
311/32
319/32
327/32

AeroBlade Grilles

Common Size Chart

www.titus-hvac.com | www.titus-energysolutions.com

MOST ECONOMICAL WAY TO


SPECIFY TITUS GRILLES
How to use this Chart:
1. Determine desired grille size by
reviewing grille performance pages
within this catalog section.
2. Use the following table, Grille
Dimensions to locate the closest
standard size to your desired
grille.
3. Review the performance data for
the standard size selected.
4. Repeat steps 1 through 3, if
necessary.
Grille Dimensions
Width
Height
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48

10

12

14

16

18

22

24

26

28

30

32

34

36

38

40

42

44

46

48

COMMON SIZE CHART

Note: Shaded areas represent common sizes.

20

G41

Notes

AeroBlade Grilles

300/350 grilles

H
www.titus-hvac.com | www.titus-energysolutions.com

www.titus-hvac.com | www.titus-energysolutions.com

Table of Contents

300/350 Grilles

300/350 grille products


300/350 Grille Products..................................................................................................................................................................H4

overview
Overview.........................................................................................................................................................................................H7

supply grilles
Supply Grilles..................................................................................................................................................................................H8
3
/4-inch Spacing - Steel...........................................................................................................................................................H8
301(RL/RS) - Single Deflection...............................................................................................................................................H8
300(RL/RS) - Double Deflection..............................................................................................................................................H8
/4-inch Spacing - Aluminum...................................................................................................................................................H9
301(FL/FS) - Single Deflection................................................................................................................................................H9
300(FL/FS) - Double Deflection...............................................................................................................................................H9

/4-inch Spacing - Stainless Steel.........................................................................................................................................H10


301(RL-SS/RS-SS) - Single Deflection...................................................................................................................................H10
300(RL-SS/RS-SS) - Double Deflection.................................................................................................................................H10
3

/2-inch Spacing - Steel.........................................................................................................................................................H11


301(RL-HD/RS-HD) - Single Deflection.................................................................................................................................H11
300(RL-HD/RS-HD) - Double Deflection................................................................................................................................H11

Performance Data.................................................................................................................................................................H12
Performance Notes...............................................................................................................................................................H17
Horizontal Deflection (Spread)..............................................................................................................................................H18
Suggested Specifications......................................................................................................................................................H19
Model Number Specification................................................................................................................................................H19

return grilles
Return Grilles................................................................................................................................................................................H23
3
/4-inch Spacing - Steel.........................................................................................................................................................H23
350(RL/RS) - 35B Deflection..................................................................................................................................................H23
350(ZRL/ZRS) - 0B Deflection................................................................................................................................................H23
/4-inch Spacing - Aluminum.................................................................................................................................................H24
350(FL/FS) - 35B Deflection...................................................................................................................................................H24
350(ZFL/ZFS) - 0B Deflection.................................................................................................................................................H24

/4-inch Spacing - Stainless Steel.........................................................................................................................................H25


350(RL-SS/RS-SS) - 45B Deflection.......................................................................................................................................H25

300/350 GRILLES

H2

/2-inch Spacing - Steel.........................................................................................................................................................H26


355(RL/RS) - 35B Deflection..................................................................................................................................................H26
355(ZRL/ZRS) - 0B Deflection................................................................................................................................................H26

/2-inch Spacing - Aluminum.................................................................................................................................................H27


355(FL/FS) - 35B Deflection...................................................................................................................................................H27
355(ZFL/ZFS) - 0B Deflection.................................................................................................................................................H27

Performance Data.................................................................................................................................................................H28
350R, 350F and 350R-SS......................................................................................................................................................H28
350ZR and 350ZF..................................................................................................................................................................H28
355R and 355F .....................................................................................................................................................................H32
355ZR and 355ZF .................................................................................................................................................................H34
Suggested Specifications......................................................................................................................................................H36
Model Number Specification................................................................................................................................................H36

Table of Contents (continued)

300/350 Grilles

Filter Return Grilles.......................................................................................................................................................................H39


Steel, Aluminum and Stainless Steel....................................................................................................................................H39
350(RLF/RSF) / 350(FLF/FSF) / 355(RLF/RSF) / 355(FLF/FSF) / 350(RLF-SS/RSF-SS)...........................................................H39
Suggested Specifications......................................................................................................................................................H40
Model Number Specification................................................................................................................................................H40

options & accessories


Option & Accessories....................................................................................................................................................................H42
Border Types.........................................................................................................................................................................H42
Accessories...........................................................................................................................................................................H42
Oversize Grille Construction..................................................................................................................................................H43
Screw Hole Location Chart...................................................................................................................................................H44

www.titus-hvac.com | www.titus-energysolutions.com

filter return grilles

300/350 GRILLES
H3

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

300/350 Grille Products

300/350 GRILLES

H4

SUPPLY GRILLES

pages: H8-H26

301(RL, RS)

300(RL, RS)

301(FL, FS)

300(FL, FS)

STEEL SINGLE
DEFLECTION GRILLES

STEEL DOUBLE
DEFLECTION GRILLES

ALUMINUM SINGLE
DEFLECTION GRILLES

ALUMINUM DOUBLE
DEFLECTION GRILLES

Available in 3/4-inch blade spacing.


Individually adjustable blades.
Blades parallel to the long
or short dimension.
Standard finish is #26 white.

Available in 3/4-inch blade spacing.


Individually adjustable blades.
Blades parallel to the long
& short dimension.
Standard finish is #26 white.

Available in 3/4-inch blade spacing.


Individually adjustable blades.
Blades parallel to the long
or short dimension.
Standard finish is #26 white.

Available in 3/4-inch blade spacing.


Individually adjustable blades.
Blades parallel to the long
& short dimension.
Standard finish is #26 white.

301(RL-SS, RS-SS)

300(RL-SS, RS-SS)

301(RL-HD, RS-HD)

300(RL-HD, RS-HD)

STAINLESS STEEL
SINGLE DEFLECTION
GRILLES

STAINLESS STEEL
DOUBLE DEFLECTION
GRILLES

HEAVY DUTY STEEL


SINGLE DEFLECTION
GRILLES

HEAVY DUTY STEEL


DOUBLE DEFLECTION
GRILLES

Available in 3/4-inch blade spacing.


Individually adjustable blades.
Blades parallel to the long
or short dimension.
Works well in corrosive
environments.
Standard finish is #04 mill.

Available in 3/4-inch blade spacing.


Individually adjustable blades.
Blades parallel to the long
& short dimension.
Standard finish is #04 mill.

Available in 1/2-inch blade spacing.


Individually adjustable blades.
Blades parallel to the long
or short dimension.
Works well in areas subject to abuse.
Standard finish is #26 white.

Available in 1/2-inch blade spacing.


Individually adjustable blades.
Blades parallel to the long
& short dimension.
Works well in areas subject to abuse.
Standard finish is #26 white.

300/350 Grilles

300/350 Grille Products (continued)

350(RL, RS)

350(ZRL, ZRS)

350(FL, FS)

350(ZFL, ZFS)

www.titus-hvac.com | www.titus-energysolutions.com

RETURN GRILLES

H
350(RL-SS, RS-SS)

355(RL, RS)

355(ZRL, ZRS)

355(FL, FS)

RETURN GRILLES




Available in 3/4-inch or 1/2-inch blade spacing.


35B, 45B and 0B deflection models to choose from.
Available in steel, aluminum and stainless steel.
Blades parallel to the long or short dimension.
Finishes are either #26 white or #04 Mill.

355(ZFL, ZFS)

300/350 GRILLES
H5

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

300/350 Grille Products (continued)

300/350 GRILLES

350 (FLF, FSF)

350 (RLF, RSF)

355 (RLF, RSF)

355 (FLF, FSF)

RETURN FILTER
GRILLES

RETURN FILTER
GRILLES

RETURN FILTER
GRILLES

RETURN FILTER
GRILLES

Available in 3/4-inch blade spacing.


35B deflection blades.
Available in steel.
Accommodates 1 or 2 thick filters.
Standard finish is #26 white.

350 (RLF-SS, RSF-SS)

H6

FILTER RETURN GRILLES

pages: H8-H26

RETURN FILTER
GRILLES




Available in 3/4-inch blade spacing.


45B deflection blades.
Available in stainless steel.
Accommodates 1 or 2 thick filters.
Standard finish is #04 mill.

Available in 3/4-inch blade spacing.


35B deflection blades.
Available in aluminum.
Accommodates 1 or 2 thick filters.
Standard finish is #26 white.

Available in 1/2-inch blade spacing.


35B deflection blades.
Available in steel.
Accommodates 1 or 2 thick filters.
Standard finish is #26 white.

Available in 1/2-inch blade spacing.


35B deflection blades.
Available in aluminum.
Accommodates 1 or 2 thick filters.
Standard finish is #26 white.

300/350 Grilles

Overview

www.titus-hvac.com | www.titus-energysolutions.com

The Titus 300/350 series of louvered supply and return grilles


are the industry standard for high quality, competitively priced
grilles. The series is available in steel, aluminum and stainless
steel material to meet any job application. The 300 series supply grilles feature adjustable louvered blades in single or double
deflection with blade spacing. For industrial and institutional
applications, the 300 series are available in a heavy duty HD
design that includes heavy gauge frame and blades. The 350
series return grilles are available in or blade spacing and
0 degree or 35 degree deflection to provide maximum versatility
for return air applications. The 350 series also include an option
for a factory installed filter rack to accommodate 1 or 2 thick
filters. Optional opposed blade dampers are available for the
300/350 series in steel, aluminum and stainless steel material
and are factory installed.
High quality, competitively priced grilles.
Defines the standard for the industry.
Available in steel, aluminum, or 304 stainless steel.
Available in supply, return, or filter return models.
Standard supply grilles available with -inch blade spacing.
Return grilles available with or -inch blade spacing.
Front blades available parallel to the long or short dimension.

300/350 OVERVIEW AT A GLANCE


Steel Border

Description

Function

Deflection Blade Spacing


Supply
Heavy
Duty
Supply
Return
Filter
Return

Single
Double
Single

35 Fixed
0 Fixed
35 Fixed
0 Fixed
35 Fixed
35 Fixed

304 Stainless Steel

Long Front
Blades

Short Front
Blades

Long Front
Blades

Short Front
Blades

Long Front
Blades

Short Front
Blades

301RL
300RL
301RLHD

301RS
300RS
301RSHD

301FL
300FL

301FS
300FS

301RL-SS
300RL-SS

301RS-SS
300RS-SS

300RLHD

300RSHD

350RL
350ZRL
355RL
355ZRL
350RLF
355RLF

350RS
350ZRS
355RS
355ZRS
350RSF
355RSF

350FL
350ZFL
355FL
355ZFL
350FLF
355FLF

350FS
350ZFS
355FS
355ZFS
350FSF
355FSF

350RL-SS

350RLF-SS

350RS-SS

350RSF-SS

front,
rear

Double

Aluminum Border

301

300

A
S
SS

Supply

Return

301HD 300HD

350

355

350Z

355Z

Note: A = Aluminum Border and Blades, S = Steel, SS = 304 Stainless Steel. Some aluminum and stainless steel models may
be constructed of all nonmagnetic components (no plastics) to meet MRI requirements. Consult your Titus representative
for specific details. See individual model information for construction details. Titus reserves the right to make product
improvements on a continual basis. As products are updated, new submittal sheets are published. Your Titus representative can
provide you with updated technical information on all products.

300/350 GRILLES

Model

Available
Material
Types

H7

Available Single Deflection Models:


301RL
301RS
Available Double Deflection Models:
300RL
300RS
Products Include:
Material: Roll-formed Steel
Borders and Blades.
Welded Border.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel Opposed-Blade Damper.

300RS

-INCH SPACING - STEEL


301RS

www.titus-hvac.com | www.titus-energysolutions.com

300/350 Grilles

Supply Grilles
301/300 (RL, RS)

301RS
-inch blade spacing.
Single deflection.
Individually adjustable blades.
Blades parallel to the
short dimension.

300RS
-inch blade spacing.
Double deflection.
Individually adjustable blades.
Front blades parallel to the
short dimension.

301RL
Same as 301RS with blades
parallel to the long dimension.

300RL
Same as 300RS with front blades
parallel to the long dimension.

Single Deflection Models 301RL/RS - Border Type 1


D plus 1"
1"

D minus "
"

9/16"

"
Screwdriver
Slot Operator
For Optional
Damper
Optional
Opposed
Blade
Damper

1"
2"

D minus "
Nominal Duct Size D"

Note:
When Damper
Is Full Open,
Add " To
Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
Double Deflection Models 300RL/RS - Border Type 1
1"
9/16"

D plus 1"
D minus "
"

"

301R, 300R

1"
3"

Screwdriver
Slot Operator
For Optional
Damper
Optional
Opposed
Blade
Damper

D minus "
Nominal Duct Size D"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.

H8

All dimensions are in inches.

300/350 Grilles

Supply Grilles (continued)

-INCH SPACING - ALUMINUM

Products Include:
Material: Roll-formed Aluminum
Border and Blades on sizes up to 24
x 24 inches. Extruded Aluminum
Border for Larger Sizes.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel or Aluminum
Opposed-Blade Damper.

301FS

Available Double Deflection Models:


300FL
300FS

300FS

Available Single Deflection Models:


301FL
301FS

301FS
Great for areas with high humidity
or subject to moisture.
-inch blade spacing.
Single deflection.
Individually adjustable blades.
Blades parallel to the
short dimension.

300FS
Great for areas with high humidity
or subject to moisture.
-inch blade spacing.
Double deflection.
Individually adjustable blades.
Front blades parallel to the
short dimension.

301FL
Same as 301FS with blades
parallel to the long dimension.

300FL
Same as 300FS with front blades
parallel to the long dimension.

Single Deflection Models 301FL/FS - Border Type 1


D plus 1"
1"

9/16"

D minus "
"

Screwdriver
Slot Operator
For Optional
Damper
Optional
Opposed
Blade
Damper

www.titus-hvac.com | www.titus-energysolutions.com

301/300 (FL, FS)

"

1"
2"
D minus "
Nominal Duct Size D"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
Double Deflection Models 300FL/FS - Border Type 1

9/16"

1"

D plus 1"
D minus "
"

"

Screwdriver
Slot Operator
For Optional
Damper
Optional
Model AG-15
Opposed
Blade
Damper

D minus "
Nominal Duct Size D"

3"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

301F, 300F

1"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

H9

300/350 Grilles

301/300 (RL-SS, RS-SS)


Available Single Deflection Models:
301RL-SS
301RS-SS
Available Double Deflection Models:
300RL-SS
300RS-SS
Products Include:
Material: 304 Stainless Steel
Border and Blades.
Welded Border.
Standard Finish - #04 Mill.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Stainless
Steel Head Sheet Metal Screws.
Optional 304 Stainless Steel
Opposed-Blade Damper.

300RS-SS

-INCH SPACING - STAINLESS STEEL


301RS-SS

www.titus-hvac.com | www.titus-energysolutions.com

Supply Grilles (continued)

301RS-SS
Great for use in corrosive
environments.
-inch blade spacing.
Single deflection.
Individually adjustable blades.
Blades parallel to the
short dimension.
Available in 316 Stainless Steel.

300RS-SS
Great for use in corrosive
environments.
-inch blade spacing.
Double deflection.
Individually adjustable blades.
Front blades parallel to the
short dimension.
Available in 316 Stainless Steel.

301RL-SS
Same as 301RS-SS with blades
parallel to the long dimension.

300RL-SS
Same as 300RS-SS with front
blades parallel to the long
dimension.

Single Deflection Models 301RL-SS/RS-SS - Border Type 1

Duct plus 1"


1"

"
15/64"

Duct Size minus "


Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 2-inch increments.
Odd and fractional sizes are available at additional cost.
Double Deflection Models 300RL-SS/RS-SS - Border Type 1

300R-SS, 301R-SS

Duct plus 1"


1 "

"

1"

Duct Size minus "


Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 2-inch increments.
Odd and fractional sizes are available at additional cost.

H10

All dimensions are in inches.

300/350 Grilles

Supply Grilles (continued)

-INCH SPACING STEEL

Products Include:
Material: Steel.
Welded Border.
Standard Finish - #26 White.
Available Border Types
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel Opposed-Blade Damper.

300RS-HD

Available Double Deflection Models:


300RL-HD
300RS-HD

301RL-HD

Available Single Deflection Models:


301RL-HD
301RS-HD
301RS-HD
Great for use in areas subject
to abuse.
-inch blade spacing.
Single deflection.
Individually adjustable blades.
Blades parallel to the
short dimension.
14-gauge blades, 16-gauge
borders.

300RS-HD
Great for use in areas subject
to abuse.
-inch blade spacing.
Double deflection.
Individually adjustable blades.
Front blades parallel to the
short dimension.
14-gauge blades, 16-gauge
borders.

301RL-HD
Same as 301RS-HD with blades
parallel to the long dimension.

300RL-HD
Same as 300RS-HD with front
blades parallel to the long
dimension.

Single Deflection Models 301RL-HD/RS-HD - Border Type 1

www.titus-hvac.com | www.titus-energysolutions.com

301/300 (RL-HD, RS-HD)

D plus 1"
1"

9/16"

Adjustable
14 Gauge
Blades

"

18 Gauge
Frame

1"

"

1"

Screwdriver
Slot Operator
For Optional
Damper

2"

Optional
Opposed
Blade
Damper

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

D minus "
Nominal Duct Size D "

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
Double Deflection Models 300RL-HD/RS-HD - Border Type 1
D plus 1"
"

Adjustable
14 Gauge
Front Blades

18 Gauge
Steel
Frame

"

1"

Screwdriver
Slot Operator
For Optional
Damper
Optional
Opposed
Blade
Damper
Adjustable
26 Gauge
Rear Blades

1"

3"

D minus "
Nominal Duct Size D "

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

300R-HD, 301R-HD

9/16"

1"

H11

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

MODELS: 300R, 300F, 300R-SS, 300R-HD, 301R, 301F, 301R-SS AND 301R-HD
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-20

Nom.
Duct
Size
( in. )
6x6

8x6

10x6

8x8

12x6

14x6

16x6
12x8

10x10

PERFORMANCE DATA

18x6

20x6
12x10

22x6

24x6
18x8
12x12
30x6
18x10

H12

Core Vel.
300
Nom. Core Vel. Press.
0.006
Duct Area
0
0.016
Area ( ft2 ) Total 22.5 0.018
( ft2 )
Press. 45
0.028
cfm
57
NC
0.25 0.19
0
5-7-14
Throw 22.5
4-6-11
(ft)
45
2-3-6
cfm
78
NC
0.33 0.26
0
5-9-16
Throw 22.5
4-7-13
(ft)
45
2-4-7
cfm
102
NC
0.42 0.34
0
6-10-19
Throw 22.5
5-8-14
(ft)
45
3-4-8
cfm
111
NC
0.44 0.37
0
6-10-19
Throw 22.5
5-8-15
(ft)
45
3-5-9
cfm
123
NC
0.50 0.41
0
7-11-20
Throw 22.5
5-8-16
(ft)
45
3-5-9
cfm
144
NC
0.58 0.48
0
7-12-22
Throw 22.5
6-9-17
(ft)
45
3-5-10
cfm
171
NC
0.67 0.57
0
8-13-24
Throw 22.5 6-10-19
(ft)
45
4-6-11
cfm
177
NC
0.69 0.59
0
8-13-24
Throw 22.5 6-10-19
(ft)
45
4-6-11
cfm
189
NC
0.75 0.63
0
8-14-25
Throw 22.5 7-11-20
(ft)
45
4-6-11
cfm
216
NC
0.83 0.72
0
9-15-27
Throw 22.5 7-11-21
(ft)
45
4-7-12
cfm
231
NC
0.92 0.77
0
9-15-28
Throw 22.5 7-12-22
(ft)
45
4-7-13
cfm
264
NC
1.00 0.88
0
10-16-30
Throw 22.5 8-12-23
(ft)
45
4-7-13
cfm
333
NC
1.25 1.11
0
11-18-34
Throw 22.5 9-14-26
(ft)
45
5-8-15

400
0.010
0.029
0.033
0.049
76
7-10-16
5-8-12
3-4-7
104
8-12-19
6-9-15
3-5-8
136
9-13-21
7-10-17
4-6-10
148
9-14-22
7-11-17
4-6-10
164
10-15-24
8-11-18
4-7-11
192
11-16-25
8-12-20
5-7-11
228
11-17-28
9-13-22
5-8-12
236
12-18-28
9-14-22
5-8-13
252
12-18-29
9-14-23
5-8-13
288
13-19-31
10-15-24
6-9-14
308
13-20-32
10-16-25
6-9-15
352
14-21-34
11-17-27
6-10-16
444
11
16-24-39
12-19-30
7-11-17

500
600
0.016
0.022
0.046
0.066
0.051
0.074
0.077
0.111
95
114
15
8-12-18 10-14-20
6-10-14
8-11-15
4-6-8
4-6-9
130
156
11
17
10-15-21 12-16-23
8-11-16
9-13-18
4-7-9
5-7-10
170
204
12
18
11-17-24 13-19-26
9-13-19 10-14-20
5-7-11
6-8-12
185
222
13
18
12-17-25 14-19-27
9-13-19 11-15-21
5-8-11
6-9-12
205
246
13
19
12-18-26 15-20-29
9-14-20 11-16-22
5-8-12
7-9-13
240
288
14
19
13-20-28 16-22-31
10-15-22 12-17-24
7-10-14
6-9-13
285
342
15
20
14-22-31 17-24-34
11-17-24 13-19-26
6-10-14
8-11-15
295
354
15
20
15-22-32 18-24-35
11-17-24 14-19-27
7-10-14
8-11-16
315
378
15
20
15-23-33 18-25-36
12-18-25 14-20-28
7-10-15
8-11-16
360
432
16
21
16-24-35 19-27-38
12-19-27 15-21-30
7-11-16
9-12-17
385
462
16
21
17-25-36 20-28-40
13-19-28 16-22-31
8-11-16
9-13-18
440
528
16
22
18-27-39 21-30-42
14-21-30 17-23-33
8-12-17 10-13-19
555
666
17
23
20-30-43 24-34-47
16-23-34 19-26-37
9-14-19 11-15-21

700
0.031
0.090
0.100
0.152
133
20
12-15-21
9-12-16
5-7-10
182
21
14-18-25
11-14-19
6-8-11
238
23
16-20-28
12-16-22
7-9-13
259
23
16-21-30
13-16-23
7-9-13
287
23
17-22-31
13-17-24
8-10-14
336
24
18-24-34
14-18-26
8-11-15
399
25
20-26-37
16-20-28
9-12-17
413
25
20-26-37
16-20-29
9-12-17
441
25
21-27-39
16-21-30
9-12-17
504
26
23-29-41
17-23-32
10-13-19
539
26
23-30-43
18-23-33
11-14-19
616
26
25-32-46
19-25-35
11-15-21
777
27
28-36-51
22-28-40
13-16-23

Performance notes appear at end of table.

NC-30
800
0.040
0.117
0.131
0.198
152
24
13-16-23
10-12-18
6-7-10
208
25
15-19-27
12-15-21
7-8-12
272
27
18-21-30
14-17-23
8-10-14
296
27
18-22-32
14-17-25
8-10-14
328
27
19-24-33
15-18-26
9-11-15
384
28
21-25-36
16-20-28
9-11-16
456
29
23-28-39
18-22-30
10-12-18
472
29
23-28-40
18-22-31
10-13-18
504
29
24-29-41
18-23-32
11-13-19
576
30
25-31-44
20-24-34
11-14-20
616
30
26-32-46
20-25-35
12-15-21
704
30
28-34-49
22-27-38
13-16-22
888
31
32-39-55
25-30-42
14-17-25

NC-40
1000
0.062
0.183
0.204
0.309
190
31
15-18-25
11-14-20
7-8-11
260
32
17-21-30
13-16-23
8-9-13
340
33
20-24-34
15-19-26
9-11-15
370
34
20-25-35
16-19-27
9-11-16
410
34
21-26-37
17-20-29
10-12-17
480
35
23-28-40
18-22-31
10-13-18
570
35
25-31-44
20-24-34
11-14-20
590
35
26-32-45
20-24-35
12-14-20
630
36
27-33-46
21-25-36
12-15-21
720
36
28-35-49
22-27-38
13-16-22
770
37
29-36-51
23-28-40
13-16-23
880
37
31-39-55
24-30-42
14-17-25
1110
38
35-43-61
27-34-47
16-19-28

1200
0.090
0.263
0.294
0.445
228
36
16-20-28
12-15-22
7-9-12
312
38
19-23-32
15-18-25
8-10-15
408
39
21-26-37
17-20-29
10-12-17
444
39
22-27-39
17-21-30
10-12-17
492
39
24-29-41
18-22-32
11-13-18
576
40
25-31-44
20-24-34
11-14-20
684
41
28-34-48
22-26-37
12-15-22
708
41
28-35-49
22-27-38
13-16-22
756
41
29-36-51
23-28-39
13-16-23
864
42
31-38-54
24-30-42
14-17-24
924
42
32-40-56
25-31-43
15-18-25
1056
43
34-42-60
27-33-46
16-19-27
1332
44
39-47-67
30-37-52
17-21-30

1400
0.122
0.358
0.401
0.606
266
41
17-21-30
13-16-23
8-10-13
364
42
20-25-35
16-19-27
9-11-16
476
43
23-28-40
18-22-31
10-13-18
518
44
24-30-42
19-23-32
11-13-19
574
44
25-31-44
20-24-34
11-14-20
672
45
28-34-48
21-26-37
12-15-21
798
45
30-37-52
23-28-40
13-17-23
826
46
31-37-53
24-29-41
14-17-24
882
46
32-39-55
24-30-42
14-17-25
1008
46
34-41-58
26-32-45
15-19-26
1078
47
35-43-60
27-33-47
16-19-27
1232
47
37-46-65
29-35-50
17-21-29
1554
48
42-51-72
32-40-56
19-23-33

300/350 Grilles

PERFORMANCE DATA
NC-20

300
0.006
0.016
0.018
0.028
366
12-19-35
9-15-27
5-8-16
405
12-20-37
10-15-29
6-9-17
411
12-20-37
10-16-29
6-9-17
447
13-21-39
10-16-30
6-9-17
477
13-22-40
10-17-31
6-10-18
486
14-22-41
11-17-31
6-10-18
546
14-23-43
11-18-33
6-10-19
621
15-25-46
12-19-36
7-11-21
642
16-25-47
12-19-36
7-11-21
687
16-26-48
12-20-37
7-12-22
738
17-27-50
13-21-39
8-12-22
771
17-27-51
13-21-40
8-12-23
825
18-28-53
14-22-41
8-13-24

400
0.010
0.029
0.033
0.049
488
11
17-25-41
13-20-31
8-11-18
540
12
18-26-43
14-21-33
8-12-19
548
12
18-27-43
14-21-33
8-12-19
596
12
19-28-45
14-22-35
8-13-20
636
12
19-29-46
15-22-36
9-13-21
648
12
19-29-47
15-22-36
9-13-21
728
13
20-31-50
16-24-38
9-14-22
828
13
22-33-53
17-25-41
10-15-24
856
13
22-33-54
17-26-42
10-15-24
916
14
23-34-56
18-27-43
10-16-25
984
14
24-36-58
18-28-45
11-16-26
1028
14
24-37-59
19-28-46
11-16-27
1100
15
25-38-61
20-29-47
11-17-27

500
0.016
0.046
0.051
0.077
610
18
21-31-45
16-24-35
9-14-20
675
18
22-33-48
17-26-37
10-15-21
685
18
22-33-48
17-26-37
10-15-22
745
19
23-35-50
18-27-39
10-16-23
795
19
24-36-52
19-28-40
11-16-23
810
19
24-36-52
19-28-41
11-16-24
910
19
26-38-55
20-30-43
12-17-25
1035
20
27-41-59
21-32-46
12-18-27
1070
20
28-42-60
22-32-47
13-19-27
1145
20
29-43-62
22-33-48
13-19-28
1230
21
30-45-64
23-35-50
13-20-29
1285
21
30-46-66
24-35-51
14-21-30
1375
21
31-47-68
24-37-53
14-21-31

600
0.022
0.066
0.074
0.111
732
23
25-35-50
20-27-39
11-16-22
810
24
26-37-52
21-29-41
12-17-24
822
24
27-37-53
21-29-41
12-17-24
894
24
28-39-55
22-30-43
13-17-25
954
24
29-40-57
22-31-44
13-18-26
972
24
29-41-57
22-31-44
13-18-26
1092
25
31-43-61
24-33-47
14-19-27
1242
25
33-46-65
25-36-50
15-21-29
1284
26
33-47-66
26-36-51
15-21-30
1374
26
34-48-68
27-37-53
16-22-31
1476
26
36-50-71
28-39-55
16-22-32
1542
26
37-51-72
28-40-56
16-23-32
1650
27
38-53-75
29-41-58
17-24-34

700
0.031
0.090
0.100
0.152
854
28
29-38-54
23-29-42
13-17-24
945
28
31-40-57
24-31-44
14-18-25
959
28
31-40-57
24-31-44
14-18-26
1043
29
32-42-59
25-33-46
15-19-27
1113
29
34-43-61
26-34-48
15-20-28
1134
29
34-44-62
26-34-48
15-20-28
1274
30
36-46-66
28-36-51
16-21-30
1449
30
38-49-70
30-38-54
17-22-31
1498
30
39-50-71
30-39-55
18-23-32
1603
30
40-52-74
31-40-57
18-23-33
1722
31
42-54-76
32-42-59
19-24-34
1799
31
43-55-78
33-43-60
19-25-35
1925
31
44-57-81
34-44-63
20-26-36

Performance notes appear at end of table.

NC-40
800
0.040
0.117
0.131
0.198
976
32
33-41-57
26-31-45
15-18-26
1080
32
35-43-60
27-33-47
16-19-27
1096
32
35-43-61
27-33-47
16-19-27
1192
33
37-45-63
28-35-49
16-20-29
1272
33
38-46-66
29-36-51
17-21-30
1296
33
38-47-66
30-36-51
17-21-30
1456
34
41-50-70
31-38-54
18-22-32
1656
34
43-53-75
33-41-58
19-24-34
1712
34
44-54-76
34-42-59
20-24-34
1832
34
45-56-79
35-43-61
20-25-35
1968
35
47-58-82
36-45-63
21-26-37
2056
35
48-59-83
37-46-65
22-27-38
2200
35
50-61-86
39-47-67
22-27-39

1000
0.062
0.183
0.204
0.309
1220
39
37-45-64
29-35-50
17-20-29
1350
39
39-48-68
30-37-52
18-21-30
1370
39
39-48-68
30-37-53
18-22-31
1490
39
41-50-71
32-39-55
18-23-32
1590
40
42-52-73
33-40-57
19-23-33
1620
40
43-52-74
33-41-57
19-24-33
1820
40
45-55-78
35-43-61
20-25-35
2070
41
48-59-84
37-46-65
22-27-38
2140
41
49-60-85
38-47-66
22-27-38
2290
41
51-62-88
39-48-68
23-28-40
2460
41
53-64-91
41-50-71
24-29-41
2570
42
54-66-93
42-51-72
24-30-42
2750
42
56-68-96
43-53-75
25-31-43

NC-50
1200
0.090
0.263
0.294
0.445
1464
44
41-50-70
31-39-55
18-22-32
1620
44
43-52-74
33-41-57
19-24-33
1644
44
43-53-75
33-41-58
19-24-34
1788
45
45-55-78
35-43-60
20-25-35
1908
45
46-57-80
36-44-62
21-26-36
1944
45
47-57-81
36-44-63
21-26-36
2184
46
50-61-86
38-47-67
22-27-39
2484
46
53-65-92
41-50-71
24-29-41
2568
46
54-66-93
42-51-72
24-30-42
2748
47
56-68-96
43-53-75
25-31-43
2952
47
58-71-100
45-55-77
26-32-45
3084
47
59-72-102
46-56-79
27-32-46
3300
47
61-75-106
47-58-82
27-34-48

1400
0.122
0.358
0.401
0.606
1708
49
44-54-76
34-42-59
20-24-34
1890
49
46-57-80
36-44-62
21-25-36
1918
49
46-57-81
36-44-62
21-26-36
2086
49
48-59-84
38-46-65
22-27-38
2226
50
50-61-87
39-48-67
23-28-39
2268
50
51-62-88
39-48-68
23-28-39
2548
50
54-66-93
42-51-72
24-30-42
2898
51
57-70-99
44-54-77
26-31-45
2996
51
58-71-101
45-55-78
26-32-45
3206
51
60-74-104
47-57-81
27-33-47
3444
51
62-76-108
48-59-84
28-34-49
3598
52
64-78-110
49-60-85
29-35-50
3850
52
66-81-114
51-63-88
30-36-51

PERFORMANCE DATA

Core Vel.
Nom. Nom. Core Vel. Press.
Duct Duct Area
0
Size Area ( ft2 ) Total 22.5
2
( in. ) ( ft )
Press. 45
cfm
NC
14x14 1.36 1.22
0
Throw 22.5
(ft)
45
cfm
36x6
NC
27x8 1.50 1.35
0
18x12
Throw 22.5
(ft)
45
cfm
NC
22x10 1.53 1.37
0
Throw 22.5
(ft)
45
cfm
30x8
NC
24x10 1.67 1.49
0
Throw 22.5
(ft)
45
cfm
42x6
NC
18x14 1.75 1.59
0
Throw 22.5
(ft)
45
cfm
NC
16x16 1.78 1.62
0
Throw 22.5
(ft)
45
cfm
48x6
36x8
NC
24x12 2.00 1.82
0
18x16
Throw 22.5
(ft)
45
cfm
NC
18x18 2.25 2.07
0
Throw 22.5
(ft)
45
cfm
42x8
NC
24x14 2.33 2.14
0
Throw 22.5
(ft)
45
cfm
36x10
NC
30x12 2.50 2.29
0
Throw 22.5
(ft)
45
cfm
48x8
NC
24x16 2.67 2.46
0
Throw 22.5
(ft)
45
cfm
NC
20x20 2.78 2.57
0
Throw 22.5
(ft)
45
cfm
36x12
NC
24x18 3.00 2.75
0
Throw 22.5
(ft)
45

NC-30

www.titus-hvac.com | www.titus-energysolutions.com

MODELS: 300R, 300F, 300R-SS, 300R-HD, 301R, 301F, 301R-SS AND 301R-HD
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

H13

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

MODELS: 300R, 300F, 300R-SS, 300R-HD, 301R, 301F, 301R-SS AND 301R-HD
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-20
Nom.
Duct
Size
( in. )
48x10
30x16
24x20

22x22

42x12
36x14

24x22

30x18

48x12
36x16
24x24

36x18

36x20
30x24

PERFORMANCE DATA

42x18

28x28

42x20
30x28

48x18
36x24

30x30

H14

Core Vel.
Nom. Core Vel. Press.
Duct Area
0
Area ( ft2 ) Total 22.5
( ft2 )
Press. 45
cfm
NC
3.33 3.11
0
Throw 22.5
(ft)
45
cfm
NC
3.36 3.14
0
Throw 22.5
(ft)
45
cfm
NC
3.50 3.22
0
Throw 22.5
(ft)
45
cfm
NC
3.67 3.43
0
Throw 22.5
(ft)
45
cfm
NC
3.75 3.5
0
Throw 22.5
(ft)
45
cfm
NC
4.00 3.75
0
Throw 22.5
(ft)
45
cfm
NC
4.50 4.22
0
Throw 22.5
(ft)
45
cfm
NC
5.00 4.71
0
Throw 22.5
(ft)
45
cfm
NC
5.25 4.94
0
Throw 22.5
(ft)
45
cfm
NC
5.44 5.16
0
Throw 22.5
(ft)
45
cfm
NC
5.83 5.51
0
Throw 22.5
(ft)
45
cfm
NC
6.00 5.66
0
Throw 22.5
(ft)
45
cfm
NC
6.25 5.94
0
Throw 22.5
(ft)
45

300
0.006
0.016
0.018
0.028
933
19-30-56
15-23-44
8-14-25
942
19-30-56
15-23-44
8-14-25
966
19-31-57
15-24-44
9-14-26
1029
20-32-59
15-25-46
9-14-27
1050
20-32-60
15-25-46
9-14-27
1125
21-33-62
16-26-48
9-15-28
1266
22-35-65
17-27-51
10-16-29
1413
23-37-69
18-29-54
10-17-31
1482
24-38-71
18-29-55
11-17-32
1548
24-39-72
19-30-56
11-17-33
1653
25-40-75
19-31-58
11-18-34
1698
25-41-76
20-32-59
11-18-34
1782
26-42-78
20-32-60
12-19-35

NC-30

400
500
600
0.010
0.016
0.022
0.029
0.046
0.066
0.033
0.051
0.074
0.049
0.077
0.111
1244
1555
1866
15
22
27
27-40-65 33-50-72 40-56-79
21-31-50 26-39-56 31-44-62
12-18-29 15-23-33 18-25-36
1256
1570
1884
15
22
27
27-40-65 34-50-73 40-56-80
21-31-50 26-39-56 31-44-62
12-18-29 15-23-33 18-25-36
1288
1610
1932
15
22
27
27-41-66 34-51-74 41-57-81
21-32-51 26-40-57 32-44-63
12-18-30 15-23-33 18-26-36
1372
1715
2058
15
22
28
28-42-68 35-53-76 42-59-83
22-33-53 27-41-59 33-46-65
13-19-31 16-24-34 19-27-38
1400
1750
2100
16
22
28
28-43-69 36-53-77 43-60-84
22-33-53 28-41-60 33-46-65
13-19-31 16-24-35 19-27-38
1500
1875
2250
16
22
28
29-44-71 37-55-80 44-62-87
23-34-55 29-43-62 34-48-68
13-20-32 17-25-36 20-28-39
1688
2110
2532
16
23
28
31-47-76 39-59-84 47-65-93
24-36-59 30-45-65 36-51-72
14-21-34 18-26-38 21-29-42
1884
2355
2826
17
23
29
33-49-80 41-62-89 49-69-98
26-38-62 32-48-69 38-54-76
15-22-36 19-28-40 22-31-44
1976
2470
2964
17
24
29
34-51-82 42-63-91 51-71-100
26-39-63 33-49-71 39-55-78
15-23-37 19-28-41 23-32-45
2064
2580
3096
17
24
29
35-52-84 43-65-93 52-72-102
27-40-65 33-50-72 40-56-79
16-23-38 19-29-42 23-33-46
2204
2755
3306
17
24
30
36-54-86 45-67-96 54-75-106
28-41-67 35-52-75 41-58-82
16-24-39 20-30-43 24-34-48
2264
2830
3396
18
24
30
36-54-87 45-68-98 54-76-107
28-42-68 35-53-76 42-59-83
16-24-39 20-31-44 24-34-48
2376
2970
3564
18
24
30
37-56-90 46-69-100 56-78-110
29-43-69 36-54-78 43-60-85
17-25-40 21-31-45 25-35-49

NC-40
700
0.031
0.090
0.100
0.152
2177
32
47-61-86
36-47-66
21-27-39
2198
32
47-61-86
37-47-67
21-27-39
2254
32
48-62-87
37-48-68
21-28-39
2401
32
49-64-90
38-49-70
22-29-41
2450
32
50-64-91
39-50-71
22-29-41
2625
33
51-67-94
40-52-73
23-30-42
2954
33
55-71-100
42-55-77
25-32-45
3297
33
58-75-106
45-58-82
26-34-48
3458
34
59-76-108
46-59-84
27-34-49
3612
34
60-78-110
47-61-86
27-35-50
3857
34
62-81-114
48-63-88
28-36-51
3962
34
63-82-116
49-63-90
28-37-52
4158
34
65-84-119
50-65-92
29-38-53

Performance notes appear at end of table.

800
0.040
0.117
0.131
0.198
2488
36
53-65-92
41-50-71
24-29-41
2512
36
53-65-92
41-50-71
24-29-41
2576
36
54-66-93
42-51-72
24-30-42
2744
36
56-68-96
43-53-75
25-31-43
2800
36
56-69-97
44-53-75
25-31-44
3000
37
58-71-101
45-55-78
26-32-45
3376
37
62-76-107
48-59-83
28-34-48
3768
37
65-80-113
50-62-87
29-36-51
3952
38
67-82-116
52-63-90
30-37-52
4128
38
68-84-118
53-65-92
31-38-53
4408
38
70-86-122
55-67-95
32-39-55
4528
38
71-87-124
55-68-96
32-39-56
4752
38
73-90-127
57-69-98
33-40-57

NC-50
1000
0.062
0.183
0.204
0.309
3110
42
59-72-103
46-56-79
27-33-46
3140
42
59-73-103
46-56-80
27-33-46
3220
43
60-74-104
47-57-81
27-33-47
3430
43
62-76-108
48-59-83
28-34-48
3500
43
63-77-109
49-60-84
28-35-49
3750
43
65-80-113
50-62-87
29-36-51
4220
44
69-84-119
53-65-93
31-38-54
4710
44
73-89-126
56-69-98
33-40-57
4940
44
75-91-129
58-71-100
34-41-58
5160
45
76-93-132
59-72-102
34-42-59
5510
45
79-96-136
61-75-106
35-43-61
5660
45
80-98-138
62-76-107
36-44-62
5940
45
82-100-142
63-78-110
37-45-64

1200
1400
0.090
0.122
0.263
0.358
0.294
0.401
0.445
0.606
3732
4354
48
52
65-79-112 70-86-121
50-62-87 54-66-94
29-36-51 32-39-55
3768
4396
48
53
65-80-113 70-86-122
50-62-87 55-67-94
29-36-51 32-39-55
3864
4508
48
53
66-81-114 71-87-123
51-63-89 55-68-96
30-36-51 32-39-56
4116
4802
48
53
68-83-118 74-90-127
53-65-91 57-70-99
31-38-53 33-41-57
4200
4900
48
53
69-84-119 74-91-129
53-65-92 58-71-100
31-38-54 33-41-58
4500
5250
49
53
71-87-123 77-94-133
55-68-96 60-73-103
32-39-55 35-42-60
5064
5908
49
54
76-93-131 82-100-141
59-72-101 63-77-110
34-42-59 37-45-64
6594
5652
50
54
80-98-138 86-106-149
62-76-107 67-82-116
36-44-62 39-48-67
5928
6916
54
50
82-100-142 88-108-153
63-78-110 68-84-118
37-45-64 40-49-69
6192
7224
50
55
84-102-145 90-110-156
65-79-112 70-86-121
38-46-65 41-50-70
6612
7714
50
55
86-106-149 93-114-161
67-82-116 72-88-125
39-48-67 42-51-73
6792
7924
50
55
87-107-152 94-116-164
68-83-117 73-90-127
39-48-68 43-52-74
7128
8316
51
55
90-110-155 97-119-168
69-85-120 75-92-130
40-49-70 44-53-75

300/350 Grilles

PERFORMANCE DATA

NC-20

Nom.
Duct
Size
( in. )
42x24
36x28

46x22

32x32

36x30

48x24
36x32

34x34

36x34

42x30

36x36

38x38

42x36

46x34

300
0.006
0.016
0.018
0.028

1998
28-44-82
21-34-64
12-20-37
2004
28-44-82
21-34-64
12-20-37
2034
28-45-83
22-34-64
12-20-37
2148
29-46-85
22-35-66
13-21-38
2289
29-47-88
23-37-68
13-21-40
2304
30-47-88
23-37-68
13-21-40
2442
30-49-91
24-38-70
14-22-41
2514
11
31-49-92
24-38-71
14-22-41
2589
11
31-50-94
24-39-72
14-23-42
2880
11
33-53-99
26-41-76
15-24-44
2892
11
33-53-99
26-41-77
15-24-44
3030
11
34-54-101
26-42-78
15-24-46
3135
11
34-55-103
27-43-80
16-25-46

400
0.010
0.029
0.033
0.049

2664
18
39-59-95
30-46-74
18-26-43
2672
18
39-59-95
30-46-74
18-27-43
2712
18
40-59-96
31-46-74
18-27-43
2864
19
41-61-98
32-47-76
18-27-44
3052
19
42-63-102
33-49-79
19-28-46
3072
19
42-63-102
33-49-79
19-28-46
3256
19
43-65-105
34-50-81
20-29-47
3352
19
44-66-106
34-51-82
20-30-48
3452
19
45-67-108
35-52-84
20-30-49
3840
20
47-71-114
36-55-88
21-32-51
3856
20
47-71-114
37-55-88
21-32-51
4040
20
48-72-117
37-56-91
22-33-53
4180
20
49-74-119
38-57-92
22-33-53

500
0.016
0.046
0.051
0.077

3330
25
49-74-106
38-57-82
22-33-48
3340
25
49-74-106
38-57-82
22-33-48
3390
25
49-74-107
38-57-83
22-33-48
3580
25
51-76-110
39-59-85
23-34-50
3815
25
52-79-114
41-61-88
24-35-51
3840
25
53-79-114
41-61-88
24-36-51
4070
26
54-81-117
42-63-91
24-37-53
4190
26
55-82-119
43-64-92
25-37-54
4315
26
56-84-121
43-65-94
25-38-54
4800
26
59-88-127
46-68-99
26-40-57
4820
26
59-88-128
46-69-99
27-40-57
5050
27
60-91-131
47-70-101
27-41-59
5225
27
61-92-133
48-71-103
28-41-60

NC-40

600
0.022
0.066
0.074
0.111

700
0.031
0.090
0.100
0.152

3996
4662
30
35
59-82-116 69-89-126
46-64-90 53-69-97
26-37-52 31-40-56
4008
4676
30
35
59-82-116 69-89-126
46-64-90 53-69-97
27-37-52 31-40-57
4068
4746
30
35
59-83-117 69-90-127
46-64-91 54-69-98
27-37-53 31-40-57
4296
5012
31
35
61-85-121 71-92-130
47-66-93 55-71-101
27-38-54 32-41-59
4578
5341
31
35
63-88-124 73-95-134
49-68-96 57-74-104
28-40-56 33-43-60
4608
5376
31
36
63-88-125 74-95-135
49-68-97 57-74-104
28-40-56 33-43-61
4884
5698
31
36
65-91-128 76-98-139
50-70-100 59-76-108
29-41-58 34-44-62
5028
5866
31
36
66-92-130 77-100-141
51-71-101 60-77-109
30-41-59 35-45-63
5178
6041
31
36
67-94-132 78-101-143
52-72-103 61-78-111
30-42-60 35-45-64
5760
6720
32
36
71-99-140 82-107-151
55-76-108 64-83-117
32-44-63 37-48-68
5784
6748
32
36
71-99-140 83-107-151
55-77-108 64-83-117
32-44-63 37-48-68
6060
7070
32
37
72-101-143 85-109-155
56-78-111 65-85-120
33-46-64 38-49-70
6270
7315
32
37
74-103-146 86-111-157
57-80-113 67-86-122
33-46-66 39-50-71

800
0.040
0.117
0.131
0.198

NC-50

1000
0.062
0.183
0.204
0.309

5328
6660
39
46
77-95-134 87-106-150
60-74-104 67-82-116
35-43-60
39-48-68
5344
6680
39
46
78-95-134 87-106-150
60-74-104 67-82-116
35-43-60
39-48-68
5424
6780
39
46
78-96-135 87-107-151
61-74-105 68-83-117
35-43-61
39-48-68
5728
7160
39
46
80-98-139 90-110-156
62-76-108 70-85-121
36-44-63
40-50-70
6104
7630
39
46
83-102-144 93-114-161
64-79-111 72-88-124
37-46-65
42-51-72
7680
6144
40
46
83-102-144 93-114-161
64-79-112 72-88-125
37-46-65
42-51-73
6512
8140
40
46
86-105-148 96-117-166
66-81-115 74-91-129
39-47-67
43-53-75
6704
8380
40
47
87-106-151 97-119-168
67-82-117 75-92-130
39-48-68
44-54-76
6904
8630
40
47
88-108-153 99-121-171
68-84-118 76-94-132
40-49-69
44-54-77
7680
9600
40
47
93-114-161 104-127-180
72-88-125 81-99-140
42-51-73
47-57-81
7712
9640
40
47
93-114-161 104-128-181
72-88-125 81-99-140
42-51-73
47-57-81
8080
10100
41
47
95-117-165 107-131-185
74-91-128 83-101-143
43-53-74
48-59-83
8360
10450
41
47
97-119-168 109-133-188
75-92-130 84-103-146
44-53-76
49-60-85

Performance notes appear at end of table.

1200
0.090
0.263
0.294
0.445

1400
0.122
0.358
0.401
0.606

7992
9324
51
56
95-116-164 102-126-178
74-90-127 79-97-138
43-52-74
46-56-80
8016
9352
51
56
95-116-165 103-126-178
74-90-128 80-97-138
43-52-74
46-57-80
8136
9492
51
56
96-117-166 103-127-179
74-91-129 80-98-139
43-53-75
47-57-81
8592
10024
51
56
98-121-170 106-130-184
76-93-132 82-101-143
44-54-77
48-59-83
9156
10682
52
56
102-124-176 110-134-190
79-96-136 85-104-147
46-56-79
49-60-86
9216
10752
52
56
102-125-176 110-135-191
79-97-137 85-104-148
46-56-79
50-61-86
9768
11396
52
56
105-128-182 113-139-196
81-100-141 88-108-152
47-58-82
51-62-88
10056
11732
52
57
106-130-184 115-141-199
82-101-143 89-109-154
48-59-83
52-63-90
10356
12082
52
57
108-132-187 117-143-202
84-103-145 90-111-157
49-60-84
53-64-91
11520
13440
53
57
114-140-197 123-151-213
88-108-153 95-117-165
51-63-89
55-68-96
11568
13496
53
57
114-140-198 123-151-214
88-108-153 96-117-166
51-63-89
55-68-96
12120
14140
53
57
117-143-202 126-155-219
91-111-157 98-120-169
53-64-91
57-70-98
12540
14630
53
58
119-146-206 128-157-222
92-113-160 99-122-172
53-66-93
58-71-100

PERFORMANCE DATA

42x34
48x30

Core Vel.
Nom. Core Vel. Press.
Duct Area
0
Area ( ft2 ) Total 22.5
( ft2 )
Press. 45
cfm
NC
7.00 6.66
0
Throw 22.5
(ft) 45
cfm
NC
7.03 6.68
0
Throw 22.5
(ft) 45
cfm
NC
7.11 6.78
0
Throw 22.5
(ft) 45
cfm
NC
7.50 7.16
0
Throw 22.5
(ft) 45
cfm
NC
8.00 7.63
0
Throw 22.5
(ft) 45
cfm
NC
8.03 7.68
0
Throw 22.5
(ft) 45
cfm
NC
8.50 8.14
0
Throw 22.5
(ft) 45
cfm
NC
8.75 8.38
0
Throw 22.5
(ft) 45
cfm
NC
9.00 8.63
0
Throw 22.5
(ft) 45
cfm
NC
10.00 9.6
0
Throw 22.5
(ft) 45
cfm
NC
10.03 9.64
0
Throw 22.5
(ft) 45
cfm
NC
10.50 10.1
0
Throw 22.5
(ft) 45
cfm
NC
10.86 10.45
0
Throw 22.5
(ft) 45

NC-30

www.titus-hvac.com | www.titus-energysolutions.com

MODELS: 300R, 300F, 300R-SS, 300R-HD, 301R, 301F, 301R-SS AND 301R-HD
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

H15

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

H16

MODELS: 300R, 300F, 300R-SS, 300R-HD, 301R, 301F, 301R-SS AND 301R-HD
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-20

Core Vel.
Nom. Nom.
Duct Duct Core Vel. Press.
Area
0
Size Area ( ft2 ) Total 22.5
2
( in. ) ( ft )
Press. 45
cfm
NC
42x38 11.08 10.67
0
Throw 22.5
(ft)
45
cfm
NC
40x40 11.11 10.7
0
Throw 22.5
(ft)
45
cfm
NC
48x36 12.00 11.57
0
Throw 22.5
(ft)
45
cfm
NC
42x42 12.25 11.82
0
Throw 22.5
(ft)
45
cfm
NC
44x44 13.44 12.99
0
Throw 22.5
(ft)
45
cfm
NC
48x42 14.00 13.54
0
Throw 22.5
(ft)
45
cfm
NC
46x46 14.69 14.22
0
Throw 22.5
(ft)
45
cfm
NC
48x46 15.33 14.85
0
Throw 22.5
(ft)
45
cfm
NC
48x48 16.00 15.50
0
Throw 22.5
(ft)
45

300
0.006
0.016
0.018
0.028

3201
12
35-56-104
27-43-81
16-25-47
3210
12
35-56-104
27-43-81
16-25-47
3471
12
36-58-108
28-45-84
16-26-49
3546
12
37-59-109
28-46-85
16-26-49
3897
12
38-62-115
30-48-89
17-28-52
4062
13
39-63-117
30-49-91
18-28-53
4266
13
40-64-120
31-50-93
18-29-54
4455
13
41-66-123
32-51-95
18-30-55
4650
13
42-67-125
33-52-97
19-30-56

NC-30

400
0.010
0.029
0.033
0.049

4268
20
50-74-120
38-58-93
22-34-54
4280
20
50-75-120
39-58-93
22-34-54
4628
21
52-78-125
40-60-97
23-35-56
4728
21
52-78-126
40-61-98
24-35-57
5196
21
55-82-133
42-64-103
25-37-60
5416
21
56-84-135
43-65-105
25-38-61
5688
21
57-86-139
44-67-107
26-39-62
5940
22
59-88-142
45-68-110
26-40-64
6200
22
60-90-145
46-70-112
27-40-65

500
0.016
0.046
0.051
0.077

5335
27
62-93-134
48-72-104
28-42-60
5350
27
62-93-134
48-72-104
28-42-61
5785
27
65-97-140
50-75-108
29-44-63
5910
27
65-98-141
51-76-110
29-44-64
6495
28
68-103-148
53-80-115
31-46-67
6770
28
70-105-151
54-81-117
31-47-68
7110
28
72-107-155
56-83-120
32-48-70
7425
28
73-110-158
57-85-123
33-49-71
7750
28
75-112-162
58-87-125
34-50-73

0, 22.5 & 45 represent blade deflection angles.


Performance data is based on duct sizes
in bold, the performance varies slightly
for duct sizes not shown in bold.
See the section, Engineering Guidelines,
for drop information when selecting larger
supply grilles for cooling purposes.
See the Performance Notes portion in this
section for notes and correction factors.

NC-40

600
0.022
0.066
0.074
0.111

6402
32
74-104-147
58-81-114
34-47-66
6420
32
75-104-147
58-81-114
34-47-66
6942
33
78-108-153
60-84-119
35-49-69
7092
33
78-109-155
61-85-120
35-49-70
7794
33
82-115-162
64-89-126
37-52-73
8124
33
84-117-166
65-91-128
38-53-75
8532
33
86-120-170
67-93-132
39-54-76
8910
34
88-123-174
68-95-134
40-55-78
9300
34
90-125-177
70-97-137
40-56-80

700
0.031
0.090
0.100
0.152

7469
37
87-112-159
67-87-123
39-51-71
7490
37
87-113-159
67-87-123
39-51-72
8099
37
90-117-165
70-91-128
41-53-74
8274
37
91-118-167
71-92-130
41-53-75
9093
38
96-124-175
74-96-136
43-56-79
9478
38
98-127-179
76-98-139
44-57-81
9954
38
100-130-183
78-101-142
45-58-83
10395
38
102-133-187
79-103-145
46-60-84
10850
38
105-135-192
81-105-148
47-61-86

NC-50

800
0.040
0.117
0.131
0.198

1000
0.062
0.183
0.204
0.309

8536
10670
41
48
98-120-170 110-134-190
76-93-132 85-104-147
44-54-76
49-60-85
8560
10700
41
48
98-120-170 110-134-190
76-93-132 85-104-147
44-54-77
49-61-86
9256
11570
41
48
102-125-177 114-140-198
79-97-137 88-108-153
46-56-80
51-63-89
9456
11820
41
48
103-126-179 115-141-200
80-98-139 89-110-155
46-57-80
52-64-90
10392
12990
42
48
108-133-187 121-148-210
84-103-145 94-115-162
49-60-84
54-67-94
10832
13540
42
49
110-135-191 124-151-214
86-105-148 96-117-166
50-61-86
56-68-96
11376
14220
42
49
113-139-196 127-155-219
88-107-152 98-120-170
51-62-88
57-70-99
11880
14850
42
49
116-142-200 129-158-224
90-110-155 100-123-174
52-64-90
58-71-101
12400
15500
42
49
118-145-205 132-162-229
92-112-159 102-125-177
53-65-92
59-73-103

1200
0.090
0.263
0.294
0.445

1400
0.122
0.358
0.401
0.606

12804
14938
53
58
120-147-208 130-159-225
93-114-161 101-123-174
54-66-94
58-71-101
12840
14980
53
58
120-147-208 130-159-225
93-114-161 101-123-174
54-66-94
58-72-101
13884
16198
53
58
125-153-217 135-165-234
97-119-168 105-128-181
56-69-97
61-74-105
14184
16548
53
58
126-155-219 137-167-236
98-120-170 106-130-183
57-70-99
61-75-106
15588
18186
54
58
133-162-230 143-175-248
103-126-178 111-136-192
60-73-103 64-79-112
16248
18956
54
59
135-166-234 146-179-253
105-128-182 113-139-196
61-75-105 66-81-114
17064
19908
54
59
139-170-240 150-183-259
107-132-186 116-142-201
62-76-108 67-83-117
17820
20790
54
59
142-174-245 153-187-265
110-134-190 119-145-205
64-78-110 69-84-119
18600
21700
55
59
145-177-251 156-192-271
112-137-194 121-148-210
65-80-113 70-86-122

See the section, Engineering Guidelines,


for catalog throw information.
Each NC value represents the noise criteria curve
that will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with
a room absorption of 10 dB, re 10-12 watts.

300/350 Grilles

PERFORMANCE DATA
Performance data
includes damper.

Drop Versus Throw Showing Ceiling Effect - 20F DT Cooling


TYPICAL 100 fpm ENVELOPE

Data obtained from tests


conducted in accordance with
ANSI/ASHRAE Standard 70-2006.

10

fpm J

ET VE
LO

CITY

1000
700
500

1000
1500

I
OC
EL
TV
JE

Drop, Ft.

pm

Core velocities are in feet


per minute.

1500

100 CFM
200
400
600
800
0f
30

All pressures are in inches


of water.

2000 CFM

15

TY

Throw values given are for


isothermal terminal velocities of
150, 100 and 50 fpm.

10

20

30
Throw, Ft.

Drop, Ft.

100 CFM

150

10

600

15

ET V
ELO

CIT

700

800
1000

500

1500

FM
2000 C

ITY

OC

20

10

20

30
Throw, Ft.

40

50

(Side view of air jet leaving wall mounted grille).

Correction Factors for 300/301 Supply Grilles


Model

Damper

Ak /Ac

Throw

Total
Pressure

NC

300R, 300F

With

0.77

1.00

1.00

0.82

0.98

0.88

-2

301R, 301F Without

Note: Throw and total pressure corrections are multipliers. The NC


correction is an addition. Ak is the flow factor. Ac is the core area
from the main table.

PERFORMANCE DATA

All Titus supply grilles can be applied


to variable air volume systems
with excellent results. For detailed
selection methods, consult your Titus
representative or the Engineering
Guidelines section of this catalog.

mJ

1000

400

EL

VARIABLE AIR VOLUME


APPLICATIONS

0 fp

200

TV

For additional information


concerning drop and throw, see
the Engineering Guidelines section
of this catalog.

TYPICAL 100 fpm ENVELOPE

JE

Dash () in space indicates NC


value less than 10.

50

Drop Versus Throw without Ceiling Effect

pm

The stated deflection settings


refer to the horizontal setting of
the blades deflection angle. For
a 20 upward deflection, use the
throw rating for the 0 setting and
the total pressure for the 22
horizontal setting.

40

(Side view of air jet leaving wall mounted grille).

0f

Bold dividing lines on H12-H16


denote ranges of NC values.

30

Each NC value represents the


noise criterion curve that will
not be exceeded by the sound
pressure in any of the octave
bands, 2 through 7. Each NC value
is based on a room absorption
of 10 dB, re 10-12 watts. Each NC
value is further based on grille
operating at a 0 deflection.
Settings of 22 or 45, increase
the stated sound levels by 1 or 7
NC, respectively.

20

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE NOTES

H17

300/350 Grilles
0B Horizontal Deflection
10

SUPPLY GRILLES

The figures depicting deflection,


throw and drop are based on actual
tests conducted by Titus. They show
the relationship of spread to throw for
a typical high side-wall supply outlet
selection.
Notice the outer shaded area
represents the 50 fpm isovel, the
white area, the 100 fpm isovel, and
the inner area, the 150 fpm isovel.
The spread angle also affects the
airstream drop amount. Always
consider for any given temperature,
volume and core velocity; the wider
spread results in a smaller drop.
See section, Engineering Guidelines,
for more drop, throw and spread
relationship information.
Titus grilles can be selected with
a single set of blades for adjusting
either horizontal or vertical deflection,
or with two sets of blades for
adjusting both horizontal and vertical
deflections.

0
DEFLECTION

50 fpm

Typical 100 fpm Envelope


150 fpm

5
10

10

20

30

40

50

THROW, FEET

Spread versus throw at 0 horizontal deflection angle (Plan view of air jet leaving
wall mounted grille).
22B Horizontal Deflection
10

22

1/2

0
22 1/
2

221/2
DEFLECTION

SPREAD, FEET

HORIZONTAL DEFLECTION
(SPREAD)

SPREAD, FEET

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

50 fpm
Typical 100 fpm
Envelope

150 fpm

5
10

10

20

30

40

THROW, FEET

Spread versus throw at 22 horizontal deflection angle (Plan view of air jet leaving
wall mounted grille).
45B Horizontal Deflection

20
15
50 fpm

45

0
45

SPREAD, FEET

PERFORMANCE DATA

10
5

Typical 100
fpm Envelope

0
150 fpm

45
DEFLECTION

10

Spread versus throw at 45


horizontal deflection angle
(Plan view of air jet leaving
wall mounted grille).

15
20
0

10

15

THROW, FEET

H18

20

25

300/350 Grilles

SUGGESTED SPECIFICATIONS

rattling. Plastic blade pivots are not acceptable.

Available Models:
301RL/301RS
300RL/300RS

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel. Damper must be operable from the
face of the grille.

Steel supply grilles shall be Titus Model 300R (double


deflection) or 301R (single deflection) of the sizes and
mounting types shown on the plans and outlet schedule.
The deflection blades shall be available parallel to the long
or short dimension of the grille. Construction shall be of
steel with a 1-inch wide border on all sides. Screw holes
shall be countersunk for a neat appearance. Corners shall
be welded with full penetration resistance welds.
Deflection blades shall be contoured to a specifically
designed and tested cross-section to meet published test
performance data. Blades shall be spaced on -inch
centers. Blades shall have steel friction pivots on both ends
to allow individual blade adjustment without loosening or

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film.
The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION

Model
301
300

Width

Module Size

Single Deflection

(note)

Double Deflection

XXX
Material

S
L

X
Height

Steel

Front Blade
Orientation

www.titus-hvac.com | www.titus-energysolutions.com

SUPPLY GRILLES - STEEL

White (std.)
Aluminum

Border Type

Parallel to Short Dim.

Surface Mount

Parallel to Long Dim.

Snap-In
Lay-In
Spline
Narrow Tee

1
2
3
4
NT

Optional

Finish
26
01

Steel Plaster
Frame

XX

XX-XX

PF
XX

Optional
Damper
Steel

AG-15

Note: Use only for Border Types 2, 3, 4, & NT.

SPECIFICATIONS
H19

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

allow individual blade adjustment without loosening or


rattling or be inserted through the frame and held tight with
steel friction wire interlocked to the frame on both ends of
each side. Plastic blade pivots are not acceptable.

SUPPLY GRILLES - ALUMINUM


Available Models:
301FL/301FS
300FL/300FS
Aluminum supply grilles shall be Titus Model 300F (double
deflection) or 301F (single deflection) of the sizes and
mounting types shown on the plans and outlet schedule.
The deflection blades shall be available parallel to the long
or short dimension of the grille or register. Construction
shall be of aluminum with a 1-inch wide border on all
sides. Sizes 24 x 24 inches and below shall have roll-formed
borders with a minimum thickness of 0.032 inch. Larger
sizes shall be constructed using continuous aluminum
extrusions with a nominal thickness of 0.040 through
0.050 inch and shall be interlocked at the four corners and
mechanically staked to form a rigid frame. Screw holes shall
be countersunk for a neat appearance.
Deflection blades shall be contoured to a specifically
designed and tested cross-section to meet published test
performance data. Blades shall be spaced on -inch
centers. Blades shall have friction pivots on both sides to

Optional opposed blade volume damper shall be constructed


of heavy gauge steel or aluminum. Damper must be
operable from the face of the grille.
The grille finish shall be #26 white. The finish shall be
an anodic acrylic paint, baked at 315 F for 30 minutes.
The pencil hardness must be HB to H. The paint must
pass a 100-hour ASTM B117 Corrosive Environments Salt
Spray Test without creepage, blistering or deterioration of
film. The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION

Model
301
300

Width

Module Size

Single Deflection

(note)

Double Deflection

XXX
Material

Aluminum

S
L

Parallel to Short Dim.

Surface Mount

Parallel to Long Dim.

Snap-In

Aluminum

Front Blade
Orientation

X
Height

Border Type

Lay-In
Spline
Narrow Tee

SPECIFICATIONS

Note: Use only for Border Types 2, 3, 4, & NT.

H20

White (std.)

1
2
3
4
NT

Finish
26
01
XX

Optional
Aluminum Plaster
Frame

PFA

XX-XX-XX

XXX

Optional
Damper
Steel
AG-15
Aluminum AG-15-AA

300/350 Grilles

SUGGESTED SPECIFICATIONS

Deflection blades shall be contoured to a specifically


designed and tested cross-section to meet published test
performance data. Blades shall be spaced on -inch
centers. Blades shall have friction pivots on both ends to
allow individual blade adjustment without loosening or
rattling. Plastic blade pivots are not acceptable.

Available Models:
301RL-SS/301RS-SS
300RL-SS/300RS-SS
Stainless Steel supply grilles shall be Titus Model 300R-SS
(double deflection) or 301R-SS (single deflection) of the
sizes and mounting types shown on the plans and outlet
schedule. The deflection blades shall be available parallel to
the long or short dimension of the grille.

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel, aluminum, or 304 stainless steel.
Damper must be operable from the face of the grille. The
grille finish shall be #04 mill.

Construction shall be of 304 stainless steel with a 1-inch


wide border on all sides. Screw holes shall be countersunk
for a neat appearance. Corners shall be welded with full
penetration resistance welds.

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

www.titus-hvac.com | www.titus-energysolutions.com

SUPPLY GRILLES - 304 STAINLESS STEEL

MODEL NUMBER SPECIFICATION


Model
301
300
XXX

Single
Deflection

Material
Type

Double
Deflection

304 Stainless
Steel

Front Blade
Orientation

S
L

Width

Optional Damper
304
AG-15-SS

Border Type

Stainless
Steel

Surface Mount

SS

XX

Parallel to Short Dim.

Mill(std.)

Parallel to Long Dim.

White

Height

04
26
Finish

XX-XX-XX

XX

Optional
304 Stainless
Steel Plaster
Frame

PFSS

SPECIFICATIONS
H21

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

SUPPLY GRILLES - HEAVY DUTY STEEL


Available Models:
301RL-HD/301RS-HD
300RL-HD/300RS-HD
Heavy Duty Steel supply grilles shall be Titus Model
300R-HD (double deflection) or 301R-HD (single deflection)
of the sizes and mounting types shown on the plans and
outlet schedule. The deflection blades shall be available
parallel to the long or short dimension of the grille.
Construction shall be of steel with a 1-inch wide border
on all sides and a minimum border gauge of 18. Screw holes
shall be countersunk for a neat appearance. Corners shall be
welded with full penetration resistance welds.

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Model
301
300

Construction Type
Single Deflection

Border Type

S
L

Optional Damper
AG-15 Steel

Surface Mount

HD

X
Height

Steel

Front Blade
Orientation

Width

Heavy Duty

Double Deflection

Material

SPECIFICATIONS

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315 F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.

Front deflection blades shall be 14-gauge steel, adjustable


from 0- 40, and spaced on -inch centers. Rear deflection
blades (if applicable) shall be 26-gauge steel spaced on
-inch centers.

XXX

H22

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel. Damper must be operable from the
face of the grille.

Parallel to Short Dim.


Parallel to Long Dim.

1
White (std.)
Aluminum

XX
26
01
Finish

XX-XX

XX

Optional
Steel Plaster
Frame

PF

300/350 Grilles

-INCH SPACING - STEEL

These Products Include:


Material: Roll-formed Steel
Border and Blades.
Welded Frame.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#2 - Snap-In
#3 - Lay-In
#4 - Spline
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws Painted White.
Optional Steel Opposed Blade Damper.

350ZRL

Available 0B Deflection Models:


350ZRL
350ZRS

350RL

Available 35B Deflection Models:


350RL
350RS
350RL
-inch blade spacing.
35 fixed deflection.
Reinforced corners.
Blades parallel to the
long dimension.

350ZRL
-inch blade spacing.
0 fixed deflection.
Reinforced corners.
Blades parallel to the
long dimension.

350RS
Same as 350RL with blades
parallel to the short dimension.

350ZRS
Same as 350ZRL with blades
parallel to the short dimension.

35 Deflection Models 350RL/RS - Border Type 1


D plus 1"
1"

D minus "
"

9/16"

For Performance Data, please refer to page


H28 for 350R, and page H30 for 350ZR.

Screwdriver
Slot Operator
For Optional
Damper

For Suggested Specification, please refer to


page H36.

Optional
Opposed
Blade
Damper

www.titus-hvac.com | www.titus-energysolutions.com

Return Grilles
350 (RL-RS, ZRL-ZRS)

35

"

1"
2"

Duct minus "


Nominal Duct Size D"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
0B Deflection Models 350ZRL/ZRS - Border Type 1
D plus 1"
1"
9/16"

D minus "
"

2"

D minus "
Nominal Duct Size D"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

350R, 350ZR

1"

Screwdriver
Slot Operator
For Optional
Damper
Optional
Opposed
Blade
Damper

"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

H23

300/350 Grilles

350 (FL-FS, ZFL-ZFS)


Available 35B Deflection Models:
350FL
350FS
Available 0B Deflection Models:
350ZFL
350ZFS
Products Include:
Material: Roll-formed aluminum for
sizes up to 24 x 24 inches; extruded
aluminum for larger sizes.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#2 - Snap-In
#3 - Lay-In
#4 - Spline
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws Painted White.
Optional Steel or Aluminum
Opposed-Blade Damper.
For Performance Data, please refer to page
H28 for 350F and page H30 for 350ZF.
For Suggested Specification, please refer to
page H37.

350ZFL

-INCH SPACING - ALUMINUM

350FL

www.titus-hvac.com | www.titus-energysolutions.com

Return Grilles (continued)

350FL
Great for areas with high humidity
or subject to moisture.
-inch blade spacing.
35 fixed deflection.
Reinforced corners.
Blades parallel to the
long dimension.

350ZFL
Great for areas with high humidity
or subject to moisture.
-inch blade spacing.
0 fixed deflection.
Reinforced corners.
Blades parallel to the
long dimension.

350FS
Same as 350FL with blades
parallel to the short dimension.

350ZFS
Same as 350ZFL with front blades
parallel to the short dimension.

35 Deflection Models: 350FL/350FS - Border Type 1


D plus 1"
1"

D minus "
"

9/16"

Screwdriver
Slot Operator
For Optional
Damper
Optional
Opposed
Blade
Damper

35

"

1"
2"

Duct minus "


Nominal Duct Size D"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
0 Deflection Models: 350ZFL/350ZFS - Border Type 1
D plus 1"
1"

350F, 350ZF

9/16"

D minus "
"

1"

Screwdriver
Slot Operator
For Optional
Damper
Optional
Opposed
Blade
Damper

2"

D minus "
Nominal Duct Size D"

H24

"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

300/350 Grilles

Return Grilles (continued)

Available 45B Deflection Models:


350RL-SS
350RS-SS
Products Include:
Material: 304 Stainless Steel
Border and Blades.
Standard Finish - #04 Mill.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch long 304 Stainless Steel
Phillips Flat Head Sheet Metal Screws.
Optional 304 Stainless Steel
Opposed-Blade Damper.
For Performance Data, please refer to page
H28.
For Suggested Specification, please refer to
page H38.

350RS-SS

350RL-SS

-INCH SPACING - STAINLESS STEEL

350RL-SS
Great for use in corrosive
environments.
-inch blade spacing.
45 fixed deflection.
Blades parallel to the
long dimension.
Available in 316 Stainless Steel.

350RS-SS
Same as 350RL-SS with blades
parallel to short dimension.
Tightly mitered corners.
Uniform polish finish.
Hollow airfoil blades anchored
with nylon pivots for tight
fit and no rattling.
Exclusive tooling and roll-forming
equipment means metal is not
contaminated with fragments
of steel or aluminum.

45 Deflection Models: 350RL-SS/350RS-SS - Border Type 1

D plus 1"
1 "

"

www.titus-hvac.com | www.titus-energysolutions.com

350 (RL-SS, RS-SS)

45
1 5 / 64 "

Duct Size minus "


Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.
Odd and fractional sizes are available at additional cost.

STAINLESS STEEL
MATERIAL PROPERTIES
AND CHARACTERISTICS
TYPE 304 STAINLESS STEEL

TYPE 316 STAINLESS STEEL

Type 316 is a chromium-nickel stainless


and heat resisting steel with superior
corrosion resistance, as compared to
other chromium-nickel steels, when
exposed to many types of chemical
corrosives such as sea water, brine

STAINLESS STEEL APPLICATIONS

Stainless steel is the number


one preferred material for those
situations where corrosion, rusting or
deterioration is a problem. However,
that is just where the uses begin.
When a high-tech effect is desired in
a restaurant, hotel or corporate lobby,
nothing beats the clean lines and
All dimensions are in inches.

aesthetic beauty of stainless steel.


There are literally hundreds of
additional applications, some include:
Pharmaceutical Plants.
Food Processing Plants.
Showers and Locker Rooms.
Commercial Kitchens.
Wastewater Treatment Plants.
Bio-Medical Manufacturing.
Coastal Areas.
Industrial Applications.
Clean Rooms.
Laboratories.
Hospitals.
Dairy Facilities.
Beverage Plants.
Chemical Plants and Schools.

350R-SS

Type 304, with its chromium-nickel


content and low carbon, is the
most versatile and widely used
type of stainless steel. It possesses
characteristics that provide resistance
to oxidation and corrosion. Type 304
stainless steel provides good resistance
to moderately acidic or caustic
solutions.

solutions and the like.


The addition of two percent
molybdenum makes type 316 more
resistant to corrosion and oxidation.
Type 316 is considerably more resistant
to solutions of sulfuric acid, chlorides,
bromides and fatty acids at high
temperatures. In the manufacture
of pharmaceuticals, stainless steels
containing molybdenum are required
in order to avoid excessive
metallic contamination.

H25

300/350 Grilles

355 (RL-RS, ZRL-ZRS)


Available 35B Deflection Models:
355RL
355RS
Available 0B Deflection Models:
355ZRL
355ZRS
Products Include:
Material: Roll-formed Steel
Border and Blades.
Welded Border.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#2 - Snap-In
#3 - Lay-In
#4 - Spline
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws Painted White.
Optional Steel Opposed Blade Damper.

355RL
-inch blade spacing.
35 fixed deflection.
Reinforced corners.
Blades parallel to the
long dimension.
355RS
Same as 355RL with blades
parallel to the short dimension.

For Suggested Specification, please refer to


page H36.

355ZRL
-inch blade spacing.
0 fixed deflection.
Reinforced corners.
Blades parallel to the
long dimension.
355ZRS
Same as 355ZRL with front blades
parallel to the short dimension.

35 Deflection Models: 355RL/355RS - Border Type 1


D plus 1"
1"
9/16"

For Performance Data, please refer to page


H32 for 355R and page H34 for 355ZR.

355ZRL

-INCH SPACING - STEEL

355RL

www.titus-hvac.com | www.titus-energysolutions.com

Return Grilles (continued)

D minus "
"

35

"

Screwdriver
Slot Operator
For Optional
Damper
Optional
Opposed
Blade
Damper

1"
2"

D minus "
Nominal Duct Size D"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
0 Deflection Models: 355ZRL/355ZRS - Border Type 1
D plus 1"
1"

355R, 355ZR

9/16"

D minus "
"

Screwdriver
Slot Operator
For Optional
Damper
Optional
Opposed
Blade
Damper

1"
2"

D minus "
Nominal Duct Size D"

H26

"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

300/350 Grilles

Return Grilles (continued)

-INCH SPACING - ALUMINUM

Products Include:
Material: Roll-formed Aluminum for
sizes up to 24 x 24 inches; Extruded
aluminum for larger sizes.
Welded Border.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#2 - Snap-In
#3 - Lay-In
#4 - Spline
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws Painted White.
Optional Steel or Aluminum
Opposed Blade Damper.
For Performance Data, please refer to page
H32 for 355R and page H34 for 355ZR.
For Suggested Specification, please refer to
page H37.

355ZFL

Available 0B Deflection Models:


355ZFL
355ZFS

355FL

Available 35B Deflection Models:


355FL
355FS
355FL
Great for areas with high humidity
or subject to moisture.
-inch blade spacing.
35 fixed deflection.
Reinforced corners.
Blades parallel to the
long dimension.

355ZFL
Great for areas with high humidity
or subject to moisture.
-inch blade spacing.
0 fixed deflection.
Reinforced corners.
Blades parallel to the
long dimension.

355FS
Same as 355FL with blades
parallel to the short dimension.

355ZFS
Same as 355ZFL with front blades
parallel to the short dimension.

35 Deflection Models: 355FL/355FS - Border Type 1


D plus 1"
1"
9/16"

D minus "
"

35

"

Screwdriver
Slot Operator
For Optional
Damper
Optional
Opposed
Blade
Damper

www.titus-hvac.com | www.titus-energysolutions.com

355 (FL-FS, ZFL-ZFS)

1"
2"

D minus "
Nominal Duct Size D"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.

0 Deflection Models: 355ZFL/355ZFS - Border Type 1


D plus 1"
1"
9/16"

D minus "
"

Optional
Opposed
Blade
Damper

1"
2"

D minus "
Nominal Duct Size D"

Note:
When Damper Is
Full Open, Add "
To Overall Depth.

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

355F, 355ZF

Screwdriver
Slot Operator
For Optional
Damper

"

H27

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

H28

300/350 Grilles

350R, 350F AND 350R-SS


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-20
Nominal Nominal Core
Core Velocity
100
200
300
400
500
600
700
800
900
Duct
Duct
Area Velocity Pressure 0.001 0.002 0.006 0.010 0.016 0.022 0.031 0.040 0.050
Size
Area ( ft2 ) Neg. Static Pressure 0.002 0.008 0.018 0.032 0.051 0.073 0.099 0.130 0.164
( in. )
( ft2 )
6x6
0.25
0.19
Airflow, cfm
19
38
57
76
95
114
133
152
171
NC
13
19
25
29
8x6
0.33
0.26
Airflow, cfm
26
52
78
104
130
156
182
208
234
20
30
NC
15
26
10x6
0.42
0.34
Airflow, cfm
34
68
102
136
170
204
272
238
306
NC
16
21
28
32
8x8
0.44
0.37
Airflow, cfm
37
74
111
148
185
222
259
296
333
NC
16
22
28
32
12x6
0.5
0.41
Airflow, cfm
41
82
123
164
205
246
287
328
369
NC
17
22
30
34
14x6
0.58
0.48
Airflow, cfm
48
96
144
192
240
288
336
384
432
NC
18
24
30
34
16x6
Airflow, cfm
57
114
171
228
285
342
399
456
513
30
12x8
0.67
0.57
NC
10
19
25
35
Airflow, cfm
59
118
177
236
295
354
413
531
472
10x10
0.69
0.59
NC
10
19
25
31
35
Airflow, cfm
63
126
189
252
315
378
441
504
567
32
18x6
0.75
0.63
NC
10
19
25
35
20x6
Airflow, cfm
72
144
216
288
360
432
504
648
576
12x10
0.83
0.72
NC
11
19
25
30
35
Airflow, cfm
77
154
231
308
385
462
539
616
693
22x6
0.92
0.77
NC
11
19
25
30
35
24x6
Airflow, cfm
88
176
264
352
440
528
616
704
792
30
12x12
1
0.88
NC
11
19
25
35
30x6
Airflow, cfm
111
222
333
444
555
666
777
999
888
18x10
1.25
1.11
NC
12
20
26
32
35
Airflow, cfm
122
244
366
488
610
732
854
976
1098
14x14
1.36
1.22
NC
12
20
27
32
35
36x6
Airflow, cfm
135
270
405
540
675
810
945
1080 1215
18x12
1.5
1.35
NC
13
20
27
32
35
685
822
959
1096 1233
Airflow, cfm
137
274
411
548
20
22x10
1.53
1.37
NC
13
27
32
36
30x8
Airflow, cfm
149
298
447
596
745
1043
1192 1341
894
24x10
1.67
1.49
NC
14
21
27
33
37
42x6
Airflow, cfm
159
318
477
636
795
954
1113
1272 1431
18x14
1.75
1.59
NC
14
21
27
33
37
16x16
1.78
1.62
Airflow, cfm
162
324
486
648
810
972
1134
1296 1458
NC
14
21
27
33
37
24x12
2
1.82
Airflow, cfm
182
364
546
728
910
1092 1274
1456 1638
18x16
NC
14
21
28
33
38
18x18
2.25
2.07
Airflow, cfm
207
414
621
828
1035
1242 1449
1656 1863
NC
14
21
28
33
38
24x14
2.33
2.14
Airflow, cfm
214
428
642
856
1070
1284 1498
1712 1926
NC
14
22
28
33
38
30x12
2.5
2.29
Airflow, cfm
229
458
687
916
1145
1374 1603
1832 2061
NC
15
22
28
33
38
24x16
2.67
2.46
Airflow, cfm
246
492
738
984
1230
1476 1722
1968 2214
NC
15
22
29
34
39
20x20
2.78
2.57
Airflow, cfm
257
514
771
1028
1285
1542 1799
2056 2313
NC
16
23
29
34
39
36x12
3
2.75
Airflow, cfm
275
550
825
1100
1375
1650 1925
2200 2475
NC
16
23
29
34
39
30x16
3.33
3.11
Airflow, cfm
311
622
933
1244
1555
1866 2177
2488 2799
24x20
NC
17
24
30
35
40
Airflow, cfm
314
628
942
1256
1570
1884 2198
2512 2826
22x22
3.36
3.14
NC
17
24
30
35
40
42x12
Airflow, cfm
322
644
966
1288
1610
1932 2254
2576 2898
36x14
3.5
3.22
NC
17
24
30
36
40
Airflow, cfm
343
686
1029
1372
1715
2058 2401
2744 3087
24x22
3.67
3.43
NC
17
24
30
36
40
Airflow, cfm
350
700
1050
1400
1750
2100 2450
2800 3150
30x18
3.75
3.5
NC
17
24
30
36
40

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC-30

NC-40

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

300/350 Grilles

PERFORMANCE DATA

NC-20 NC-30
Nominal Nominal Core
Duct
Duct
Area
Size
Area
( ft2 )
2
( in. )
( ft )
48x12
24x24
4
3.75
4.5

4.22

4.71

42x18

5.25

4.94

28x28
42x20
30x28
48x18
36x24

5.44

5.16

5.83

5.51

5.66

30x30
42x24
36x28

6.25

5.94

6.66

46x22

7.03

6.68

32x32

7.11

6.78

36x30
48x24
36x32

7.5

7.16

7.63

34x34

8.03

7.68

36x34

8.5

8.14

42x30

8.75

8.38

36x36
42x34
48x30

8.63

10

9.6

38x38

10.03

9.64

42x36

10.5

10.1

46x34

10.86

10.45

42x38

11.08

10.67

40x40

11.11

10.7

48x36

12

11.57

42x42

12.25

11.82

44x44

13.44

12.99

48x42

14

13.54

46x46

14.69

14.22

48x46

15.33

14.85

48x48

16

15.5

Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC

cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

100
200
300
400
500
600
700
800
900
0.001 0.002 0.006 0.010 0.016 0.022 0.031 0.040 0.050
0.002 0.008 0.018 0.032 0.051 0.073 0.099 0.130 0.164
375
422
471
494
516
551
566
594
666
668
678
716
763
768
814
838
863
960
964
1010
1045
1067
1070
1157
1182
1299
1354
1422
1485
1550
-

750
844
942
988
1032
1102
1132
1188
1332
1336
1356
1432
1526
1536
1628
1676
1726
1920
1928
2020
2090
2134
2140
2314
2364
2598
2708
2844
2970
3100
-

1125
1266
1413
1482
1548
1653
1698
1782
1998
2004
2034
2148
2289
2304
2442
2514
2589
2880
2892
3030
3135
3201
3210
3471
3546
3897
4062
4266
4455
4650
-

1500
1688
1884
1976
2064
2204
10
2264
10
2376
10
2664
10
2672
10
2712
10
2864
10
3052
10
3072
10
3256
11
3352
11
3452
11
3840
11
3856
11
4040
11
4180
11
4268
11
4280
11
4628
11
4728
11
5196
12
5416
12
5688
12
5940
12
6200
13

1875
18
2110
18
2355
18
2470
18
2580
18
2755
18
2830
18
2970
18
3330
19
3340
19
3390
19
3580
19
3815
19
3840
19
4070
19
4190
20
4315
20
4800
20
4820
20
5050
20
5225
20
5335
20
5350
20
5785
20
5910
20
6495
21
6770
21
7110
21
7425
22
7750
22

2250
25
2532
25
2826
25
2964
25
3096
25
3306
26
3396
26
3564
26
3996
26
4008
27
4068
27
4296
27
4578
27
4608
27
4884
27
5028
27
5178
27
5760
27
5784
27
6060
27
6270
27
6402
27
6420
27
6942
27
7092
27
7794
28
8124
28
8532
28
8910
28
9300
29

2625
37
2954
31
3297
31
3458
31
3612
32
3857
32
3962
32
4158
32
4662
32
4676
32
4746
32
5012
32
5341
32
5376
32
5698
32
5866
32
6041
33
6720
33
6748
33
7070
33
7315
33
7469
33
7490
33
8099
33
8274
33
9093
34
9478
34
9954
35
10395
35
10850
35

3000
38
3376
38
3768
38
3952
38
4128
38
4408
38
4528
38
4752
38
5328
38
5344
38
5424
38
5728
38
6104
38
6144
38
6512
38
6704
38
6904
38
7680
38
7712
38
8080
38
8360
38
8536
38
8560
38
9256
39
9456
39
10392
39
10832
40
11376
40
11880
40
12400
40

3375
41
3798
41
4239
41
4446
41
4644
41
4959
41
5094
41
5346
41
5994
41
6012
42
6102
42
6444
42
6867
42
6912
42
7326
42
7542
42
7767
43
8640
43
8676
43
9090
43
9405
43
9603
43
9630
43
10413
44
10638
44
11691
44
12186
45
12798
45
13365
45
13950
45

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

36x18
36x20
30x24

Core Velocity
Velocity Pressure
Neg. Static Pressure

NC-40

www.titus-hvac.com | www.titus-energysolutions.com

350R, 350F AND 350R-SS


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

H29

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

H30

350ZR AND 350ZF


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-10 NC-20
Nominal Nominal Core
Duct
Duct
Area
Size
Area
( ft2 )
2
( in. )
( ft )
6x6
0.25
0.19
8x6

0.33

0.26

10x6

0.42

0.34

8x8

0.44

0.37

12x6

0.5

0.41

14x6

0.58

0.48

16x6
12x8

0.67

0.57

10x10

0.69

0.59

18x6
20x6
12x10

0.75

0.63

0.83

0.72

22x6
24x6
12x12
30x6
18x10

0.92

0.77

0.88

1.25

1.11

14x14
36x6
18x12

1.36

1.22

1.5

1.35

22x10
30x8
24x10
42x6
18x14
16x16

1.53

1.37

1.67

1.49

1.75
1.78

1.59
1.62

24x12
18x16
18x18

1.82

2.25

2.07

24x14

2.33

2.14

30x12

2.5

2.29

24x16

2.67

2.46

20x20

2.78

2.57

36x12

2.75

30x16
24x20

3.33

3.11

22x22
42x12
36x14

3.36

3.14

3.5

3.22

24x22

3.67

3.43

30x18

3.75

3.5

Core Velocity
Velocity Pressure
Neg. Static Pressure
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC

cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC-30

NC-40

300
400
500
600
700
900 1100 1300 1500
0.006 0.010 0.016 0.022 0.031 0.050 0.075 0.105 0.140
0.012 0.022 0.034 0.049 0.067 0.111 0.165 0.231 0.307
57
78
102
111
123
144
171
177
189
216
231
264
333
366
405
411
447
477
486
546
621
642
687
738
771
825
933
942
966
1029
1050
-

76
104
136
148
164
192
228
236
252
288
308
352
444
488
540
548
596
636
648
728
828
856
916
984
1028
1100
1244
1256
1288
1372
1400
-

95
130
170
185
205
240
285
295
315
360
385
440
555
11
610
11
675
12
685
12
745
12
795
13
810
13
910
13
1035
14
1070
14
1145
14
1230
15
1285
15
1375
15
1555
16
1570
16
1610
16
1715
16
1750
16

114
156
204
11
222
12
246
12
288
13
342
13
354
14
378
14
432
14
462
15
528
15
666
16
732
17
810
17
822
17
894
18
954
18
972
18
1092
18
1242
19
1284
19
1374
19
1476
20
1542
20
1650
20
1866
21
1884
21
1932
21
2058
21
2100
21

133
13
182
14
238
16
259
16
287
16
336
17
399
18
413
18
441
18
504
19
539
19
616
20
777
21
854
21
945
22
959
22
1043
22
1113
22
1134
22
1274
23
1449
23
1498
24
1603
24
1722
24
1799
24
1925
25
2177
25
2198
25
2254
25
2401
26
2450
26

171
20
234
22
306
23
333
23
369
24
432
24
513
25
531
25
567
25
648
26
693
26
792
27
999
28
1098
28
1215
29
1233
29
1341
29
1431
29
1458
30
1638
30
1863
31
1926
31
2061
31
2214
31
2313
32
2475
32
2799
32
2826
32
2898
33
3087
33
3150
33

209
26
286
27
374
28
407
29
451
29
528
30
627
31
649
31
693
31
792
32
847
32
968
33
1221
34
1342
34
1485
35
1507
35
1639
35
1749
35
1782
35
2002
36
2277
36
2354
37
2519
37
2706
37
2827
37
3025
38
3421
38
3454
38
3542
38
3773
39
3850
39

247
31
338
32
442
33
481
34
533
34
624
35
741
36
767
36
819
36
936
37
1001
37
1144
37
1443
38
1586
39
1755
39
1781
39
1937
40
2067
40
2106
40
2366
41
2691
41
2782
41
2977
42
3198
42
3341
42
3575
42
4043
43
4082
43
4186
43
4459
43
4550
43

285
35
390
36
510
37
555
38
615
38
720
39
855
40
885
40
945
40
1080
41
1155
41
1320
42
1665
43
1830
43
2025
43
2055
43
2235
44
2385
44
2430
44
2730
45
3105
45
3210
45
3435
46
3690
46
3855
46
4125
47
4665
47
4710
47
4830
47
5145
47
5250
48

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

300/350 Grilles

PERFORMANCE DATA

NC-10
Nominal Nominal Core
Duct
Duct
Area
Size
Area
( ft2 )
( in. )
( ft2 )
48x12
24x24
4
3.75
4.5

4.22

4.71

42x18

5.25

4.94

28x28
42x20
30x28
48x18
36x24

5.44

5.16

5.83

5.51

5.66

30x30
42x24
36x28

6.25

5.94

6.66

46x22

7.03

6.68

32x32

7.11

6.78

36x30
48x24
36x32

7.5

7.16

7.63

34x34

8.03

7.68

36x34

8.5

8.14

42x30

8.75

8.38

36x36
42x34
48x30

8.63

10

9.6

38x38

10.03

9.64

42x36

10.5

10.1

46x34

10.86

10.45

42x38

11.08

10.67

40x40

11.11

10.7

48x36

12

11.57

42x42

12.25

11.82

44x44

13.44

12.99

48x42

14

13.54

46x46

14.69

14.22

48x46

15.33

14.85

48x48

16

15.5

Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC
Airflow,
NC

cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm

NC-40

300
400
500
600
700
900 1100 1300 1500
0.006 0.010 0.016 0.022 0.031 0.050 0.075 0.105 0.140
0.012 0.022 0.034 0.049 0.067 0.111 0.165 0.231 0.307
1125
1266
1413
1482
1548
1653
1698
1782
1998
2004
2034
2148
2289
2304
2442
2514
2589
2880
2892
3030
3135
3201
3210
3471
3546
3897
4062
4266
4455
4650
-

1500
1688
1884
11
1976
11
2064
11
2204
12
2264
12
2376
12
2664
12
2672
12
2712
13
2864
13
3052
13
3072
13
3256
13
3352
13
3452
14
3840
14
3856
14
4040
14
4180
14
4268
14
4280
15
4628
15
4728
15
5196
15
5416
16
5688
16
5940
16
6200
16

1875
16
2110
17
2355
17
2470
18
2580
18
2755
18
2830
18
2970
18
3330
19
3340
19
3390
19
3580
19
3815
19
3840
19
4070
20
4190
20
4315
20
4800
20
4820
20
5050
21
5225
21
5335
21
5350
21
5785
21
5910
21
6495
22
6770
22
7110
22
7425
22
7750
23

2250
22
2532
22
2826
23
2964
23
3096
23
3306
23
3396
23
3564
24
3996
24
4008
24
4068
24
4296
24
4578
25
4608
25
4884
25
5028
25
5178
25
5760
26
5784
26
6060
26
6270
26
6402
26
6420
26
6942
26
7092
27
7794
27
8124
27
8532
27
8910
28
9300
28

2625
26
2954
27
3297
27
3458
27
3612
27
3857
28
3962
28
4158
28
4662
28
4676
29
4746
29
5012
29
5341
29
5376
29
5698
29
5866
29
6041
30
6720
30
6748
30
7070
30
7315
30
7469
31
7490
31
8099
31
8274
31
9093
31
9478
32
9954
32
10395
32
10850
32

3375
33
3798
34
4239
34
4446
34
4644
35
4959
35
5094
35
5346
35
5994
36
6012
36
6102
36
6444
36
6867
36
6912
36
7326
37
7542
37
7767
37
8640
37
8676
37
9090
38
9405
38
9603
38
9630
38
10413
38
10638
38
11691
39
12186
39
12798
39
13365
39
13950
39

4125
39
4642
39
5181
40
5434
40
5676
40
6061
41
6226
41
6534
41
7326
41
7348
41
7458
42
7876
42
8393
42
8448
42
8954
42
9218
42
9493
43
10560
43
10604
43
11110
43
11495
43
11737
44
11770
44
12727
44
13002
44
14289
44
14894
45
15642
45
16335
45
17050
45

4875
5625
44
48
5486
6330
44
48
6123
7065
45
49
6422
7410
45
49
6708
7740
49
45
7163
8265
45
50
7358
8490
46
50
7722
8910
46
50
8658
9990
46
50
8684 10020
46
50
8814 10170
46
50
9308 10740
47
51
9919 11445
47
51
9984 11520
47
51
10582 12210
47
51
10894 12570
47
51
11219 12945
47
51
12480 14400
48
52
12532 14460
48
52
13130 15150
48
52
13585 15675
48
52
13871 16005
48
52
13910 16050
48
52
15041 17355
49
53
15366 17730
49
53
16887 19485
49
53
17602 20310
49
53
18486 21330
50
54
19305 22275
50
54
20150 23250
50
54

PERFORMANCE DATA

36x18
36x20
30x24

Core Velocity
Velocity Pressure
Neg. Static Pressure

NC-20 NC-30

www.titus-hvac.com | www.titus-energysolutions.com

350ZR AND 350ZF


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

NC-50

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

H31

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

H32

300/350 Grilles

355R AND 355F


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-20

NC-30

Nominal Nominal Core


Core Velocity
100
200
300
400
500
600
700
800
900
Duct
Duct
Area Velocity Pressure 0.001 0.002 0.006 0.010 0.016 0.022 0.031 0.040 0.050
Size
Area ( ft2 ) Neg. Static Pressure 0.003 0.011 0.026 0.045 0.071 0.102 0.139 0.182 0.230
( in. )
( ft2 )
6x6
0.25
0.19
Airflow, cfm
19
38
57
76
95
114
133
152
171
NC
10
18
25
29
33
8x6
0.33
0.26
Airflow, cfm
26
52
78
104
130
156
182
208
234
30
NC
11
19
25
35
10x6
0.42
0.34
Airflow, cfm
34
68
102
136
170
204
238
306
272
NC
12
20
26
31
36
8x8
0.44
0.37
Airflow, cfm
37
74
111
148
185
222
259
296
333
NC
12
20
26
31
36
12x6
0.5
0.41
Airflow, cfm
41
82
123
164
205
246
287
328
369
NC
12
20
26
32
36
14x6
0.58
0.48
Airflow, cfm
48
96
144
192
240
288
336
384
432
20
NC
12
26
32
37
16x6
Airflow, cfm
57
114
171
228
285
399
456
513
342
12x8
0.67
0.57
NC
13
21
27
32
38
Airflow, cfm
59
118
177
236
295
354
413
472
531
10x10
0.69
0.59
NC
13
21
27
32
38
Airflow, cfm
63
126
189
252
315
378
441
504
567
18x6
0.75
0.63
NC
14
22
28
33
38
20x6
Airflow, cfm
72
144
216
288
360
432
504
576
648
12x10
0.83
0.72
NC
14
22
28
33
38
Airflow, cfm
77
154
231
308
385
462
539
616
693
22x6
0.92
0.77
NC
14
22
28
34
38
24x6
Airflow, cfm
88
176
264
352
440
528
616
704
792
12x12
1
0.88
NC
15
22
28
34
39
30x6
Airflow, cfm
111
222
333
444
555
666
777
888
999
18x10
1.25
1.11
NC
15
22
28
34
39
Airflow, cfm
122
244
366
488
610
732
854
976
1098
14x14
1.36
1.22
NC
16
23
29
34
39
36x6
Airflow, cfm
135
270
405
540
675
810
945
1080
1215
18x12
1.5
1.35
NC
16
24
29
34
39
548
685
822
959
1096
1233
Airflow, cfm
137
274
411
22x10
1.53
1.37
NC
16
24
30
35
39
30x8
Airflow, cfm
149
298
447
596
745
894
1043
1192
1341
24x10
1.67
1.49
NC
16
24
30
35
39
42x6
Airflow, cfm
159
318
477
636
795
954
1113
1272
1431
18x14
1.75
1.59
NC
17
24
30
35
39
16x16
1.78
1.62
Airflow, cfm
162
324
486
648
810
972
1134
1296
1458
NC
17
24
30
35
39
24x12
2
1.82
Airflow, cfm
182
364
546
728
910
1092
1274
1456
1638
18x16
NC
17
24
30
35
39
18x18
2.25
2.07
Airflow, cfm
207
414
621
828
1035
1242
1449
1656
1863
31
NC
18
25
35
40
24x14
2.33
2.14
Airflow, cfm
214
428
642
856
1070
1284
1712
1926
1498
NC
18
25
31
35
40
30x12
2.5
2.29
Airflow, cfm
229
458
687
916
1145
1374
1603
1832
2061
NC
18
25
31
35
40
24x16
2.67
2.46
Airflow, cfm
246
492
738
984
1230
1476
1722
1968
2214
NC
10
18
25
32
36
39
20x20
2.78
2.57
Airflow, cfm
257
514
771
1028
1285
1542
1799
2056
2313
40
NC
10
18
25
32
36
36x12
3
2.75
Airflow, cfm
275
550
825
1100
1375
1650
1925
2200
2475
NC
10
19
26
32
37
42
30x16
3.33
3.11
Airflow, cfm
311
622
933
1244
1555
1866
2177
2488
2799
24x20
NC
10
19
26
32
37
42
Airflow, cfm
314
628
942
1256
1570
1884
2198
2512
2826
22x22
3.36
3.14
NC
10
19
26
33
38
42
42x12
Airflow, cfm
322
644
966
1288
1610
1932
2254
2576
2898
36x14
3.5
3.22
NC
10
19
26
33
38
43
Airflow, cfm
343
686
1029
1372
1715
2058
2401
2744
3087
24x22
3.67
3.43
NC
10
19
26
33
38
43
Airflow, cfm
350
700
1050
1400
1750
2100
2450
2800
3150
30x18
3.75
3.5
NC
10
19
26
33
38
43

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC-40

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

300/350 Grilles

PERFORMANCE DATA
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

NC-20 NC-30
Nominal Nominal Core
Duct
Duct
Area
Size
Area
( ft2 )
( in. )
( ft2 )
48x12
24x24
4
3.75
4.5

4.22

4.71

42x18

5.25

4.94

28x28
42x20
30x28
48x18
36x24

5.44

5.16

5.83

5.51

5.66

30x30
42x24
36x28

6.25

5.94

6.66

46x22

7.03

6.68

32x32

7.11

6.78

36x30
48x24
36x32

7.5

7.16

7.63

34x34

8.03

7.68

36x34

8.5

8.14

42x30

8.75

8.38

36x36
42x34
48x30

8.63

10

9.6

38x38

10.03

9.64

42x36

10.5

10.1

46x34

10.86

10.45

42x38

11.08

10.67

40x40

11.11

10.7

48x36

12

11.57

42x42

12.25

11.82

44x44

13.44

12.99

48x42

14

13.54

46x46

14.69

14.22

48x46

15.33

14.85

48x48

16

15.5

Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC

100
200
300
400
500
600
700
800
900
0.001 0.002 0.006 0.010 0.016 0.022 0.031 0.040 0.050
0.003 0.011 0.026 0.045 0.071 0.102 0.139 0.182 0.230
375
422
471
494
516
551
566
594
666
668
678
716
763
768
814
838
863
960
964
1010
1045
1067
1070
1157
1182
1299
1354
1422
1485
1550
-

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

750
844
942
988
1032
1102
1132
1188
1332
1336
1356
1432
1526
1536
1628
1676
1726
1920
1928
2020
2090
2134
2140
2314
2364
2598
2708
2844
2970
3100
-

1125
1266
1413
1482
1548
1653
1698
1782
1998
2004
2034
2148
2289
2304
2442
2514
2589
2880
2892
3030
3135
3201
3210
3471
3546
3897
4062
4266
4455
4650
-

1500
10
1688
10
1884
11
1976
12
2064
12
2204
12
2264
12
2376
12
2664
13
2672
13
2712
13
2864
14
3052
14
3072
14
3256
14
3352
14
3452
14
3840
14
3856
14
4040
15
4180
15
4268
15
4280
15
4628
15
4728
15
5196
15
5416
16
5688
16
5940
16
6200
16

1875
19
2110
19
2355
19
2470
20
2580
21
2755
21
2830
21
2970
21
3330
22
3340
22
3390
22
3580
23
3815
23
3840
23
4070
23
4190
23
4315
23
4800
23
4820
23
5050
23
5225
23
5335
23
5350
23
5785
23
5910
24
6495
24
6770
24
7110
25
7425
25
7750
25

2250
26
2532
26
2826
27
2964
28
3096
28
3306
28
3396
28
3564
28
3996
29
4008
29
4068
29
4296
30
4578
30
4608
30
4884
30
5028
30
5178
30
5760
30
5784
30
6060
31
6270
31
6402
31
6420
31
6942
31
7092
31
7794
32
8124
32
8532
32
8910
32
9300
32

2625
33
2954
33
3297
33
3458
34
3612
34
3857
34
3962
35
4158
35
4662
35
4676
35
4746
35
5012
36
5341
36
5376
36
5698
36
5866
36
6041
36
6720
36
6748
36
7070
37
7315
37
7469
37
7490
37
8099
37
8274
37
9093
38
9478
38
9954
39
10395
39
10850
39

3000
39
3376
39
3768
38
3952
39
4128
40
4408
40
4528
40
4752
40
5328
40
5344
40
5424
40
5728
41
6104
41
6144
41
6512
41
6704
41
6904
41
7680
41
7712
41
8080
42
8360
42
8536
42
8560
42
9256
42
9456
42
10392
43
10832
43
11376
44
11880
44
12400
44

3375
43
3798
43
4239
43
4446
44
4644
44
4959
44
5094
44
5346
44
5994
45
6012
45
6102
45
6444
46
6867
46
6912
46
7326
46
7542
46
7767
46
8640
46
8676
46
9090
47
9405
47
9603
47
9630
47
10413
47
10638
47
11691
48
12186
48
12798
48
13365
48
13950
48

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

36x18
36x20
30x24

Core Velocity
Velocity Pressure
Neg. Static Pressure

NC-40

www.titus-hvac.com | www.titus-energysolutions.com

355R AND 355F

H33

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

355ZR AND 355ZF


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC-10
Nominal Nominal Core
Duct
Duct
Area
Size
Area
( ft2 )
2
( in. )
( ft )
6x6
0.25
0.19
8x6

0.33

0.26

10x6

0.42

0.34

8x8

0.44

0.37

12x6

0.5

0.41

14x6

0.58

0.48

16x6
12x8

0.67

0.57

10x10

0.69

0.59

18x6
20x6
12x10

0.75

0.63

0.83

0.72

22x6
24x6
12x12
30x6
18x10

0.92

0.77

0.88

1.25

1.11

14x14
36x6
18x12

1.36

1.22

1.5

1.35

22x10
30x8
24x10
42x6
18x14
16x16

1.53

1.37

1.67

1.49

1.75
1.78

1.59
1.62

24x12
18x16
18x18

1.82

2.25

2.07

24x14

2.33

2.14

30x12

2.5

2.29

24x16

2.67

2.46

20x20

2.78

2.57

36x12

2.75

30x16
24x20

3.33

3.11

22x22
42x12
36x14

3.36

3.14

3.5

3.22

24x22

3.67

3.43

30x18

3.75

3.5

Core Velocity
Velocity Pressure
Neg. Static Pressure
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC

NC-20

NC-30

300
400
500
600
700
800
900
1000 1100
0.006 0.010 0.016 0.022 0.031 0.040 0.050 0.062 0.075
0.013 0.022 0.035 0.050 0.068 0.089 0.113 0.140 0.169
57
78
102
111
123
144
171
177
189
216
231
264
333
366
405
411
447
477
486
546
621
642
687
738
771
825
933
942
966
1029
1050
-

76
104
136
148
164
192
228
236
252
288
308
352
444
488
540
548
596
636
11
648
11
728
11
828
12
856
12
916
12
984
13
1028
13
1100
13
1244
14
1256
14
1288
14
1372
14
1400
14

95
130
170
185
205
11
240
11
285
12
295
12
315
12
360
13
385
13
440
14
555
15
610
15
675
16
685
16
745
16
795
17
810
17
910
17
1035
18
1070
18
1145
18
1230
18
1285
19
1375
19
1555
19
1570
19
1610
20
1715
20
1750
20

114
12
156
13
204
15
222
15
246
15
288
16
342
17
354
17
378
17
432
18
462
18
528
19
666
20
732
20
810
21
822
21
894
21
954
21
972
21
1092
22
1242
22
1284
23
1374
23
1476
23
1542
23
1650
24
1866
24
1884
24
1932
24
2058
25
2100
25

133
16
182
17
238
19
259
19
287
19
336
20
399
21
413
21
441
21
504
22
539
22
616
23
777
24
854
24
945
25
959
25
1043
25
1113
25
1134
25
1274
26
1449
26
1498
27
1603
27
1722
27
1799
27
1925
28
2177
28
2198
28
2254
28
2401
29
2450
29

152
20
208
21
272
22
296
23
328
23
384
24
456
24
472
25
504
25
576
25
616
26
704
26
888
27
976
28
1080
28
1096
28
1192
29
1272
29
1296
29
1456
29
1656
30
1712
30
1832
30
1968
31
2056
31
2200
31
2488
32
2512
32
2576
32
2744
32
2800
32

171
23
234
24
306
24
333
26
369
26
432
27
513
27
531
28
567
28
648
29
693
29
792
29
999
30
1098
31
1215
31
1233
31
1341
32
1431
32
1458
32
1638
33
1863
33
1926
33
2061
34
2214
34
2313
34
2475
34
2799
35
2826
35
2898
35
3087
35
3150
35

190
25
260
27
340
28
370
28
410
29
480
30
570
30
590
30
630
31
720
31
770
32
880
32
1110
33
1220
34
1350
34
1370
34
1490
34
1590
35
1620
35
1820
35
2070
36
2140
36
2290
36
2460
37
2570
37
2750
37
3110
38
3140
38
3220
38
3430
38
3500
38

209
28
286
29
374
31
407
31
451
31
528
32
627
33
649
33
693
33
792
34
847
34
968
35
1221
36
1342
36
1485
37
1507
37
1639
37
1749
37
1782
37
2002
38
2277
38
2354
39
2519
39
2706
39
2827
39
3025
40
3421
40
3454
40
3542
40
3773
41
3850
41

NC-40

H34

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

300/350 Grilles

PERFORMANCE DATA

NC-10 NC-20
Nominal Nominal Core
Duct
Duct
Area
Size
Area
( ft2 )
( in. )
( ft2 )
5.25

4.94

28x28
42x20
30x28
48x18
36x24

5.44

5.16

5.83

5.51

5.66

30x30
42x24
36x28

6.25

5.94

6.66

46x22

7.03

6.68

32x32

7.11

6.78

36x30
48x24
36x32

7.5

7.16

7.63

34x34

8.03

7.68

36x34

8.5

8.14

42x30

8.75

8.38

36x36
42x34
48x30

8.63

10

9.6

38x38

10.03

9.64

42x36

10.5

10.1

46x34

10.86

10.45

42x38

11.08

10.67

40x40

11.11

10.7

48x36

12

11.57

42x42

12.25

11.82

44x44

13.44

12.99

48x42

14

13.54

46x46

14.69

14.22

48x46

15.33

14.85

48x48

16

15.5

Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC-40

300
400
500
600
700
800
900
1000 1100
0.006 0.010 0.016 0.022 0.031 0.040 0.050 0.062 0.075
0.013 0.022 0.035 0.050 0.068 0.089 0.113 0.140 0.169
1482
1548
1653
1698
1782
1998
2004
2034
2148
2289
2304
2442
2514
2589
2880
11
2892
11
3030
11
3135
11
3201
11
3210
11
3471
12
3546
12
3897
12
4062
12
4266
13
4455
13
4650
13

1976
16
2064
16
2204
16
2264
16
2376
16
2664
17
2672
17
2712
17
2864
17
3052
17
3072
18
3256
18
3352
18
3452
18
3840
18
3856
18
4040
19
4180
19
4268
19
4280
19
4628
19
4728
19
5196
20
5416
20
5688
20
5940
20
6200
21

2470
21
2580
22
2755
22
2830
22
2970
22
3330
23
3340
23
3390
23
3580
23
3815
23
3840
23
4070
24
4190
24
4315
24
4800
24
4820
24
5050
25
5225
25
5335
25
5350
25
5785
25
5910
25
6495
26
6770
26
7110
26
7425
26
7750
26

2964
26
3096
26
3306
27
3396
27
3564
27
3996
28
4008
28
4068
28
4296
28
4578
28
4608
28
4884
28
5028
29
5178
29
5760
29
5784
29
6060
29
6270
29
6402
30
6420
30
6942
30
7092
30
7794
30
8124
31
8532
31
8910
31
9300
31

3458
30
3612
30
3857
31
3962
31
4158
31
4662
32
4676
32
4746
32
5012
32
5341
32
5376
32
5698
32
5866
33
6041
33
6720
33
6748
33
7070
33
7315
34
7469
34
7490
34
8099
34
8274
34
9093
34
9478
35
9954
35
10395
35
10850
35

3952
34
4128
34
4408
34
4528
34
4752
35
5328
35
5344
35
5424
35
5728
35
6104
36
6144
36
6512
36
6704
36
6904
36
7680
37
7712
37
8080
37
8360
37
8536
37
8560
37
9256
37
9456
38
10392
38
10832
38
11376
38
11880
39
12400
39

4446
37
4644
37
4959
37
5094
37
5346
38
5994
38
6012
38
6102
38
6444
38
6867
39
6912
39
7326
39
7542
39
7767
39
8640
40
8676
40
9090
40
9405
40
9603
40
9630
40
10413
41
10638
41
11691
41
12186
41
12798
41
13365
42
13950
42

4940
5434
40
42
5160
5676
40
42
5510
6061
40
43
6226
5660
40
43
5940
6534
40
43
6660
7326
41
43
6680
7348
41
43
6780
7458
41
44
7160
7876
41
44
7630
8393
42
44
7680
8448
42
44
8140
8954
42
44
8380
9218
42
44
8630
9493
42
45
9600 10560
43
45
9640 10604
43
45
10100 11110
43
45
10450 11495
43
45
10670 11737
43
45
10700 11770
43
45
11570 12727
43
46
11820 13002
43
46
12990 14289
44
46
13540 14894
44
47
14220 15642
44
47
14850 16335
44
47
15500 17050
45
47

NC based on room absorption of 10 dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

42x18

Core Velocity
Velocity Pressure
Neg. Static Pressure

NC-30

www.titus-hvac.com | www.titus-energysolutions.com

355ZR AND 355ZF


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

H35

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

RETURN GRILLES - STEEL

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel. Damper must be operable from the
face of the grille.

Available Models:
350R/350ZR
355R/355ZR
Steel return grilles shall be Titus Model 350R (-inch blade
spacing) or 355R (-inch blade spacing) of the sizes and
mounting types shown on the plans and outlet schedule.
The fixed deflection blades shall be available parallel to the
long or short dimension of the grille. Construction shall be of
steel with a 1-inch wide border on all sides. Screw holes
shall be countersunk for a neat appearance. Corners shall
be welded with full penetration resistance welds.
Deflection blades shall be contoured to a specifically
designed and tested cross-section to meet published test
performance data. Blades shall be firmly held in place by
mullions from behind the grille and fixed to the grille by
welding in place. Blade deflection angle shall be available
at 0 (Models 350ZR and 355ZR) or 35 (Models 350R and
355R).

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315 F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film.
The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Model
350
350Z
355
355Z

35, Spacing

Width

0, Spacing

Module Size

35, Spacing

(note)

0, Spacing

XXXX
Material

R
Steel
Front Blade
Orientation

X
S
L

X
Height

Aluminum

Border Type

Parallel to Short Dim.

Surface Mount

Parallel to Long Dim.

Snap-In
Lay-In
Spline
Narrow Tee

SPECIFICATIONS

Note: Use only for Border Types 2, 3, 4, & NT.

H36

White (std.)

1
2
3
4
NT

Finish
26
01
XX

Optional
PF

Steel Plaster
Frame

XX-XX

Optional
Damper
Steel AG-15

XX

300/350 Grilles

SUGGESTED SPECIFICATIONS

Available Models:
350F/350ZF
355F/355ZF
Aluminum return grilles shall be Titus Model 350F (-inch
blade spacing) or 355F (-inch blade spacing) of the
sizes and mounting types shown on the plans and outlet
schedule. The fixed deflection blades shall be available
parallel to the long or short dimension of the grille.
Construction shall be of extruded aluminum with a 1-inch
wide border on all sides. Minimum border thickness shall be
0.040-0.050 inch. Sizes 24 x 24 inches and smaller shall be
constructed using a roll-formed frame.
Corners shall be welded with full penetration resistance
welds. Sizes larger than 24 x 24 inches shall be constructed
by using heavy aluminum extrusions and shall be interlocked
at the four corners and mechanically staked to form a
rigid frame. Screw holes shall be counter-sunk for a neat
appearance.

Optional opposed blade volume damper shall be constructed


of heavy gauge steel or aluminum. Damper must be
operable from the face of the grille.
The grille finish shall be #26 white. The finish shall be an
anodic acrylic paint, baked at 315 F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

Deflection blades shall be contoured to a specifically


designed and tested cross-section to meet published test
performance data. Blades shall be firmly held in place

MODEL NUMBER SPECIFICATION


Model
350
350Z
355
355Z

35, Spacing

Width

0, Spacing

Module Size

35, Spacing

(note)

0, Spacing

XXXX
Material

S
L

X
Height

Aluminum

Front Blade
Orientation

www.titus-hvac.com | www.titus-energysolutions.com

by mullions from behind the grille and fixed in place by


crimping or welding. Blade deflection angle shall be available
at 0 (Models 350ZF and 355ZF) or 35 (Models 350F and
355F).

RETURN GRILLES - ALUMINUM

White (std.)
Aluminum

Border Type

Parallel to Short Dim.

Surface Mount

Parallel to Long Dim.

Snap-In
Lay-In
Spline
Narrow Tee

1
2
3
4
NT

Finish
26
01
XX

Optional
PF

Steel Plaster
Frame

Aluminum Plaster
Frame

PFA

XX-XX-XX

XXX

Optional
Damper
Steel
AG-15
Aluminum AG-15-AA

Note: Use only for Border Types 2, 3, 4, & NT.

SPECIFICATIONS
H37

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

mullions from behind the grille and fixed to the grille by


welding in place. Blade deflection angle shall be 45 (Models
350R-SS and 355R-SS).

RETURN GRILLES - 304 STAINLESS STEEL


Available Model:
350R-SS

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel, aluminum, or 304 stainless steel.
Damper must be operable from the face of the grille. The
grille finish shall be #04 mill.

Stainless steel return grilles shall be Titus Model 350R-SS


(-inch blade spacing) of the sizes and mounting types
shown on the plans and outlet schedule. The fixed
deflection blades shall be available parallel to the long or
short dimension of the grille. Construction shall be of 304
stainless steel with a 1-inch wide border on all sides.
Screw holes shall be countersunk for a neat appearance.
Corners shall be welded with full penetration resistance
welds.

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

Deflection blades shall be contoured to a specifically


designed and tested cross-section to meet published test
performance data. Blades shall be firmly held in place by

MODEL NUMBER SPECIFICATION

Model
350
XXX

Material
Type
45,
Spacing

Width

Front Blade
Orientation

S
L

SPECIFICATIONS

Stainless
Steel

Surface Mount

SS

XX

Parallel to Short Dim.

Mill (std.)

Parallel to Long Dim.

White

Height

H38

Optional Damper
304
AG-15-SS

Border Type

304 Stainless
Steel

04
26
Finish

XX-XX-XX

XX

Optional
304 Stainless Steel
Plaster Frame

PFSS

300/350 Grilles
355RLF

STEEL, ALUMINUM AND


STAINLESS STEEL
Available Steel Models:

-inch Spacing


350RLF1 1-inch Filter


350RSF1 1-inch Filter


350RLF2 2-inch Filter


350RSF2 2-inch Filter




350RLF1/350RLF2 - Border Type 1(Surface Mount) & Border Type 3 (Lay-in T-Bar)

FASTENER

-inch Spacing

355RLF1 1-inch Filter

355RSF1 1-inch Filter

355RLF2 2-inch Filter

355RSF2 2-inch Filter

3/4

7/16

1 1/4

2" FOR 1" FILTER


3 1/8" FOR 2" FILTER

Available Aluminum Models:



-inch Spacing


350FLF1 1-inch Filter


350FSF1 1-inch Filter


350FLF2 2-inch Filter


350FSF2 2-inch Filter

NOMINAL DUCT SIZE (D)


D PLUS 1/4"

D PLUS 3 3/4"

Available sizes (D x D) are 10 x 8 inches through 48 x 36 inches in 1-inch increments.


Odd sizes are available at additional cost. D PLUS 3 3/4"

FILTER RETURN GRILLES


-inch Spacing


355FLF1 1-inch Filter


355FSF1 1-inch Filter


355FLF2 2-inch Filter


355FSF2 2-inch Filter

Available 304 Stainless Steel Models:

-inch Spacing


350RLF1-SS 1-inch Filter


350RSF1-SS 1-inch Filter


350RLF2-SS 2-inch Filter


350RSF2-SS 2-inch Filter

Products Include:
35 Fixed Deflection - Steel
and Aluminum.
45 Fixed Deflection - Stainless Steel.
-Turn Fastener.
1- or 2-inch Filter Frame.
Available Border Types:
#1 - Surface Mount
#3 - Lay-In
Standard Finish - #26 White.
(Steel and Aluminum Models).
Standard FInish - #04 Mill.
(Stainless Steel Models).

HINGE

D PLUS 3 3/4"

www.titus-hvac.com | www.titus-energysolutions.com

Filter Return Grilles


350/355 (RLF-RSF, FLF-FSF, -SS)

Please refer to page I68


for Hinge Locations

All dimensions are in inches.

H39

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

300/350 FILTER RETURN


GRILLES - STEEL
Available Models:
350RLF1
350RSF1
350RLF2
350RSF2
355RLF1
355RSF1
355RLF2
355RSF2
Note: For specification
information, please refer
to page H36 for 350R
specifications and specify
a 1- or 2-inch filter frame.

300/350 FILTER RETURN


GRILLES - ALUMINUM
Available Models:
350FLF1
350FSF1
350FLF2
350FSF2
355FLF1
355FSF1
355FLF2
355FSF2
Note: For specification
information, please refer
to page H37 for 350F
specifications and specify a
1- or 2-inch filter frame.

MODEL NUMBER SPECIFICATION


Model
350
350Z
355
355Z

Filter
Thickness
1-inch
F1
2-inch
F2

35, Spacing
0, Spacing
35, Spacing
0, Spacing

XXXX
Material

Steel
Front Blade
Orientation

S
L

Width

Module Size
(note)

Finish
26
01

White (std.)
Aluminum

Height

Border Type

Parallel to Short Dim.


Parallel to Long Dim.

XX

1
3

Surface Mount
Lay-In

Note: Use only for Border Type 3.

MODEL NUMBER SPECIFICATION


Model
350
350Z
355
355Z

Filter
Thickness
1-inch
F1
2-inch
F2

35, Spacing
0, Spacing
35, Spacing
0, Spacing

XXXX

Material

Aluminum

Front Blade
Orientation

S
L

Width

Finish
26
01

Module Size

White (std.)
Aluminum

(note)

Height

Border Type

Parallel to Short Dim.


Parallel to Long Dim.

XX

1
3

Surface Mount
Lay-In

Note: Use only for Border Type 3.

300/350 FILTER RETURN GRILLES


- 304 STAINLESS STEEL

SPECIFICATIONS

MODEL NUMBER SPECIFICATION

H40

Available Models:
350RLF1-SS
350RSF1-SS
350RLF2-SS
350RSF2-SS
Note: For specification
information, please refer
to page H38 for 350R-SS
specifications and specify a
1- or 2-inch filter frame.

Model
350
XXX

Material Type
45,
Spacing

R
Front Blade
Orientation

Parallel to Short Dim.


Parallel to Long Dim.

Width

304 Stainless Steel

S
L

F1
F2

Border Type
Surface Mount

SS
Filter
Thickness
1-inch
2-inch

1
Mill (std.)
White

Height

XX
04
26
Finish

300/350 Grilles

OPTIONS & ACCESSORIES

Model
Number
350
350
350
355
355
350RF
350RF
350FF
350FF
350RF
350
355
350RF
350RF
350
355
350FF
350FF
350
355
350
355
350
355
350
355
AG-15
AG-15-AA
AG-15-SS

Type
Grille
Stl.-Supply
Stl.-Supply
Al.-Supply
Al.-Supply
SS-Supply
SS-Supply
Stl.-Supply
Stl.-Supply
SS-Supply
SS-Supply

Type
Deflection
Single
Double
Single
Double
Single
Double
Single
Double
Single
Double

Deflection Blade Border


Degrees Spacing Type OS FR #01 #04 #20 #21 #26 #84
1
Y Y Y Y Y Y Y Y
Adjustable

Adjustable
1
Y Y Y Y Y Y Y Y

Adjustable
1
Y Y Y Y Y Y Y Y

Adjustable
1
Y Y Y Y Y Y Y Y

Adjustable
1
Y Y N Y N N Y N

Adjustable
1
Y Y N Y N N Y N

Adjustable
1
Y Y Y Y Y Y Y Y

Adjustable
1
Y Y Y Y Y Y Y Y

Adjustable
1
Y Y Y Y Y Y Y Y

Adjustable
1
Y Y Y Y Y Y Y Y

C
Y
Y
Y
Y
N
N
N
N
N
N

DS IS FG PF PFAP EQT
Y Y Y Y
N
Y
Y Y Y Y
N
Y
Y Y Y Y
N
Y
Y Y Y Y
N
Y
N N Y Y
N
Y
N N Y Y
N
Y
N N Y Y
N
Y
N N Y Y
N
Y
N N Y Y
N
Y
N N Y Y
N
Y

Type
Type
Deflection Blade Border
Grille
Deflection Degrees Spacing Type OS FR #01 #04 #20 #21 #26 #84
Stl.-Return
Single
0/35
1
Y Y Y Y Y Y Y Y

Al.-Return
Single
0/35
1
Y Y Y Y Y Y Y Y

SS-Return
Single
0/45
1
Y Y N Y N N Y N

Stl.-Return
Single
0/35
1
Y Y Y Y Y Y Y Y

Al.-Return
Single
0/35
1
Y Y Y Y Y Y Y Y

Stl. Filter Return Single


35
1
N N Y Y Y Y Y Y

Stl. Filter Return Single


35
1
N N Y Y Y Y Y Y

Al-Filter Return
Single
35
1
N N Y Y Y Y Y Y

Al-Filter Return
Single
35
1
N N Y Y Y Y Y Y

SS Filter Return
Single
45
1
N N N Y N N Y N

Stl.-Return
Single
0/35
3
N N Y Y Y Y Y Y

Stl.-Return
Single
0/35
3
N N Y Y Y Y Y Y

Stl. Filter Return Single


35
3
N N Y Y Y Y Y Y

Stl. Filter Return Single


35
3
N N Y Y Y Y Y Y

Al.-Return
Single
0/35
3
N N Y Y Y Y Y Y

Al.-Return
Single
0/35
3
N N Y Y Y Y Y Y

Al-Filter Return
Single
35
3
N N Y Y Y Y Y Y

Al-Filter Return
Single
35
3
N N Y Y Y Y Y Y

Stl.-Return
Single
0/35
2
N N Y Y Y Y Y Y

Stl.-Return
Single
0/35
2
N N Y Y Y Y Y Y

Al.-Return
Single
0/35
2
N N Y Y Y Y Y Y

Al.-Return
Single
0/35
2
N N Y Y Y Y Y Y

Stl.-Return
Single
0/35
4
N N Y Y Y Y Y Y

Stl.-Return
Single
0/35
4
N N Y Y Y Y Y Y

Al.-Return
Single
0/35
4
N N Y Y Y Y Y Y

Al.-Return
Single
0/35
4
N N Y Y Y Y Y Y

Stl.-Damper
--------Y Y N Y N N Y Y
Al.-Damper
--------Y Y N Y N N Y Y
SS.-Damper
--------Y Y N Y N N N N

C
Y
Y
N
N
N
Y
Y
Y
Y
N
N
N
Y
Y
N
N
Y
Y
N
N
N
N
N
N
N
N
-------

DS
Y
Y
N
Y
Y
N
N
N
N
N
Y
Y
N
N
Y
Y
N
N
Y
Y
Y
Y
Y
Y
Y
Y
-------

IS
Y
Y
N
Y
Y
N
N
N
N
N
Y
Y
N
N
Y
Y
N
N
Y
Y
Y
Y
Y
Y
Y
Y
-------

FG
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
-------

PF PFAP EQT
Y
N
Y
Y
N
Y
Y
N
Y
Y
N
Y
Y
N
Y
Y
N
Y
Y
N
Y
Y
N
Y
Y
N
Y
Y
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
N
N
Y
--- ------- ------- -----

www.titus-hvac.com | www.titus-energysolutions.com

Model
Number
301
300
301
300
301
300
301HD
300HD
301HD
300HD

Caution: All options are not available in all combinations. Check with your Titus representative for details.
Titus reserves the right to discontinue or add options at any time without notice.

SERIES FINISHES, OPTIONS AND ACCESSORIES

Note: An asterisk (*) indicates additional cost.


Concealed mounting not available with damper

Options & Accessories:



OS
Oversize

FR
Fractional Size

C
Concealed Fasteners

DS
Debris Screen -inch Square Mesh

Galvanized Steel Screen

IS
Insect Screen 1/16 Square Mesh

Galvanized Steel Screen

FG
Foam Gasket On Back Side of Border

PF
Steel Plaster Frame

PFA
Aluminum Plaster Frame

PF-SS Stainless Steel Plaster Frame

EQT
Earthquake Tab For Safety Wiring

to Support Structure

OPTIONS & ACCESSORIES

Finishes:

#01 Aluminum Colored Paint

#04 Mill Finish

#20 Envirotherm Color To Match Sample*

#21 Envirothane Color To Match Sample*

#25 Off White*

#26 White (standard on most models)

#84 Black*

H41

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

OPTIONS & ACCESSORIES


BORDER TYPES

Snap-In

BORDER TYPE 2
SNAP-IN (PANEL MOUNTED)

Available Module Size


24 x 24 inches

BORDER TYPE 3
LAY-IN (PANEL MOUNTED)


Available Module Sizes
12 x 12 inches
24 x 12 inches
36 x 12 inches
48 x 12 inches
24 x 24 inches
36 x 24 inches
48 x 24 inches

13/16"

Ceiling Module Size


minus 1/16"
Note: Maximum grille area is module size minus 4 inches.
Lay-In (Panel Mounted)

BORDER TYPE 4

SPLINE (PANEL MOUNTED)



Available Module Sizes
24 x 24 inches

Ceiling Module Size


minus "
Note: Maximum grille area is module size minus 4 inches.

BORDER TYPE NT
NARROW TEE (PANEL MOUNTED)
Available Module Sizes
24 x 12 inches
24 x 24 inches

Spline (Panel Mounted)

Note: Filter grilles not available in all


module sizes.

"
"
Ceiling Module Size
minus "

Note: Maximum grille area is module size minus 4 inches.

ACCESSORIES

NARROW TEE

Narrow Tee (Panel Mounted)

OPTIONS & ACCESSORIES

TYPE A FASTENING - SURFACE


MOUNT

Standard For All Border Type


1 Surface Mount Grilles.
Note: For screw hole locations
see the chart, Screw Hole
Location Chart.

16 "
5

TYPE C FASTENING CONCEALED MOUNTING

16 "

Ceiling Module Minus 3/4"

Available on Most Models


with Border Type 1.
Type A - External Screw

Type C - Concealed Screw


1" x " Angle Clip
(by others)
Existing Duct

#8 Screw
(by others)

Ceiling or Wall

1" x " Angle Clip


Attached to Grille
(by Titus)

H42
Flange or Grille

300/350 Grilles

Oversize Grille Construction

www.titus-hvac.com | www.titus-energysolutions.com

300/350 SERIES

FOR DUCTS OR OPENINGS LARGER THAN 48 INCHES
Joining With Aluminum Mullions or Alignment Tabs
Notes:
Detail A-A is used for vertical joints. The frames of both vertical sides of the joint are sheared
and then butted together. Alignment tabs serve to keep the face surfaces parallel.
C full
Detail B-BAis used for horizontal B
joining. Horizontal frames are installed
A A
A A
A
width with an aluminum mullion in betweenA each
frame.
This page does not apply to filter grilles.
This page is for Border Type 1 grilles only.
8"-48" Wide

49"-96" Wide

97"-144" Wide

A A

A A

97"-144" Wide and


49"-96" High

49"-96" Wide and


49"-96" High

6-48" Wide and


49"-96" High

A A

.750

2.750
Frame

.375

234"

Frame
5

6-48" Wide and


97"-144" High

Frame

Frame

DETAIL A-A

4"

BB Mullion

DETAIL B-B
DETAIL B-B

16 "

OVERSIZE GRILLE CONSTRUCTION

Alignment
Tab

H43

300/350 Grilles

www.titus-hvac.com | www.titus-energysolutions.com

Screw Hole Location Chart


FOR USE WITH 300/350 GRILLES
UP TO 48 X 36 INCHES
(NOT FOR USE WITH FILTER GRILLES)

HOW TO USE THESE CHARTS


1. Determine desired grille size.
2. Find the grille size in Grille
Size Chart.
3. Use the Grille Size Chart to select the
proper diagram number. The number
corresponds to the diagrams in the
Screw Hole Layout Diagrams 1-14.

1"

5/8"

Section A-A

Grille Size Chart

SCREW HOLE LOCATION CHART

Screw Layout Diagrams 1 - 14

H44

Note 1: This chart provides general information concerning location of screw holes. Screw hole location is subject to change
without notice. Titus does not recommend pre-drilling mounting surfaces for screws. Use the grille as a template. This chart
applies to border type 1 only.
Note 2: All holes are located 5/8-inch from outside edge. Location of hole according to number required. (One Hole) Located
midway between ends. (Two Holes) Locate each hole 3 inches from each end. (Three Holes) Locate one hole 3 inches from
each end and center the third hole.

All dimensions are in inches.

specialized grilles

I
www.titus-hvac.com | www.titus-energysolutions.com

www.titus-hvac.com | www.titus-energysolutions.com

Table of Contents

Specialized Grilles

specialized grille products


Specialized Grille Products..............................................................................................................................................................I4

overview
Overview........................................................................................................................................................................................I10

eggcrate return grilles


Eggcrate Return Grilles..................................................................................................................................................................I12
50F Aluminum Border, 50F-NT Aluminum / Narrow Tee ......................................................................................................I12
50R-SS Stainless Steel...........................................................................................................................................................I13
50FF Aluminum / Filter Return...............................................................................................................................................I14
Performance Data..................................................................................................................................................................I15
Suggested Specifications.......................................................................................................................................................I17
Model Number Specification.................................................................................................................................................I17

perforated return grilles


Perforated Return Grilles...............................................................................................................................................................I18
8F Aluminum..........................................................................................................................................................................I18
8FF Aluminum Filter Return...................................................................................................................................................I18
8R Steel..................................................................................................................................................................................I18
8RF Steel Filter Return...........................................................................................................................................................I18
8SS 304 Stainless Steel.........................................................................................................................................................I18
Performance Data .................................................................................................................................................................I19
Suggested Specifications.......................................................................................................................................................I21
Model Number Specification.................................................................................................................................................I21

steel heavy duty bar return grilles

SPECIALIZED GRILLES

Steel Heavy Duty Bar Return Grilles..............................................................................................................................................I22


33(RL/RS) / 38B Deflection.....................................................................................................................................................I22
30(RL/RS) / 0B Deflection.......................................................................................................................................................I22
33(RFL/RFS) / 38B Deflection / Filter......................................................................................................................................I23
30(RFL/RSF) / 0B Deflection / Filter........................................................................................................................................I23
Performance Data .................................................................................................................................................................I24
Suggested Specifications.......................................................................................................................................................I28
Model Number Specification.................................................................................................................................................I28

I2

aluminum heavy duty bar return grilles


Aluminum Heavy Duty Bar Return Grilles.....................................................................................................................................I29
63(FLFS) / 30B Deflection.......................................................................................................................................................I29
60(FL/FS) / 0B Deflection........................................................................................................................................................I29
Performance Data..................................................................................................................................................................I30
Suggested Specifications.......................................................................................................................................................I34
Model Number Specification.................................................................................................................................................I34

Table of Contents (continued)

Specialized Grilles

Spiral Duct-Mounted Grilles..........................................................................................................................................................I35


S301(FLFS) / Single Deflection / Radius End Caps / Supply..................................................................................................I35
S300(FL/FS) / Double Deflection / Radius End Caps / Supply................................................................................................I35
US301(FLFS) / Single Deflection / Universal End Caps / Supply...........................................................................................I36
US300(FL/FS) / Double Deflection / Universal End Caps / Supply.........................................................................................I36
S8F / Radius End Caps / Perforated Return...........................................................................................................................I37
US8F / Universal End Caps / Perforated Return.....................................................................................................................I37
Performance Data..................................................................................................................................................................I38
Suggested Specifications.......................................................................................................................................................I42
Model Number Specification.................................................................................................................................................I42

door grilles
Door Grilles....................................................................................................................................................................................I44
T-700(L/S) / Steel...................................................................................................................................................................I44
CT-700(L/S) / Aluminum.........................................................................................................................................................I45
Performance Data..................................................................................................................................................................I46
Suggested Specifications.......................................................................................................................................................I47
Model Number Specification.................................................................................................................................................I47

reversible core narrow blade grilles


Reversible Core Narrow Blade Grilles............................................................................................................................................I48
1700(L/S)................................................................................................................................................................................I48
Performance Data..................................................................................................................................................................I49
Suggested Specification........................................................................................................................................................I51
Model Number Specification.................................................................................................................................................I51

www.titus-hvac.com | www.titus-energysolutions.com

spiral duct mounted grilles

commercial/industrial louvered supply grilles


Commercial/Industrial Louvered Supply Grilles.............................................................................................................................I52
JFA(L/S) / Pole Operated........................................................................................................................................................I52
Performance Data..................................................................................................................................................................I53
Suggested Specification........................................................................................................................................................I56
Model Number Specification.................................................................................................................................................I56

drum louver

SPECIALIZED GRILLES

Drum Louvers.................................................................................................................................................................................I57
DL...........................................................................................................................................................................................I57
DL-SV......................................................................................................................................................................................I58
Performance Data..................................................................................................................................................................I59
Suggested Specification........................................................................................................................................................I60
Model Number Specification.................................................................................................................................................I60
US-DL.....................................................................................................................................................................................I61
Performance Data..................................................................................................................................................................I62
Suggested Specification........................................................................................................................................................I64
Model Number Specification.................................................................................................................................................I64

options & accessories


Options & Accessories...................................................................................................................................................................I65
Hinge Locations.............................................................................................................................................................................I68

I3

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

Specialized Grille Products

SPECIALIZED GRILLES

I4

EGGCRATE RETURN GRILLES

pages: I12-I17

50F
RETURN GRILLE



Aluminum border & grid.


Available in 3 grid core sizes.
Highest free area of any return grille.
MRI compatible.

50FF
RETURN FILTER GRILLE
Aluminum border & grid.
1/2 x 1/2 x 1/2 core.
Highest free area of any return grille.

50F-NT
RETURN GRILLE NARROW TEE
Designed to fit narrow
tee ceiling grids.
Aluminum border & grid.
Available in 3 grid core sizes.
Highest free area of any return grille.

50R

50R-SS

RETURN GRILLE

RETURN GRILLE

Steel border & aluminum grid.


Can be used in firerated applications.
Available in 3 grid core sizes.
Highest free area of any return grille.

Stainless steel border & grid.


1/2 x 1/2 x 1/2 core.
Highest free area of any return grille.

Specialized Grilles

Specialized Grille Products (continued)

8F

8FF

8R

8RF

RETURN GRILLE

RETURN FILTER GRILLE

RETURN GRILLE

RETURN FILTER GRILLE

Aluminum construction.
51% free area perforated face.
Matches appearance of
perforated supply diffusers.

Aluminum construction.
51% free area perforated face.
Matches appearance of
perforated supply diffusers.
Accommodates 1 or 2 thick filters.

Steel construction.
51% free area perforated face.
Matches appearance of
perforated supply diffusers.

Steel construction.
51% free area perforated face.
Matches appearance of
perforated supply diffusers.
Accommodates 1 or 2 thick filters.

RETURN GRILLE
Stainless steel construction (#304).
51% free area perforated face.
Matches appearance of
perforated supply diffusers.

SPECIALIZED GRILLES

8SS

www.titus-hvac.com | www.titus-energysolutions.com

PERFORATED RETURN GRILLES

pages: I18-I21

I5

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

Specialized Grille Products (continued)

STEEL HEAVY DUTY BAR RETURN GRILLES

pages: I22-I28

33 (RL, RS)

30 (RL, RS)

HEAVY DUTY RETURN


GRILLE

HEAVY DUTY RETURN


GRILLE

HEAVY DUTY FILTER


RETURN GRILLE

HEAVY DUTY RETURN


GRILLE

Steel construction.
1

/2-inch blade spacing.
38B fixed deflection.
Great for use in gymnasiums
and areas where rugged
construction is required.

Steel construction.
3

/8-inch blade spacing.
0B fixed deflection.
Great for use in gymnasiums
and areas where rugged
construction is required.

Steel construction.
1

/2-inch blade spacing.
38B fixed deflection.
Accommodates 1 or 2 thick filters.
Great for use in gymnasiums
and areas where rugged
construction is required.

Steel construction.
3

/8-inch blade spacing.
0B fixed deflection.
Accommodates 1 or 2 thick filters.
Great for use in gymnasiums
and areas where rugged
construction is required.

SPECIALIZED GRILLES

30 (RFL, RFS)

ALUMINUM HEAVY DUTY BAR RETURN GRILLES

pages: I29-I34

I6

33 (RFL, RFS)

63 (FL, FS)

60 (FL, FS)

HEAVY DUTY RETURN GRILLE

HEAVY DUTY RETURN GRILLE

Aluminum construction.
1

/2-inch blade spacing.
30B fixed deflection.
MRI compatible.
Great for use in gymnasiums and areas where rugged construction is required.

Aluminum construction.
1

/2-inch blade spacing.
0B fixed deflection.
Great for use in gymnasiums and areas where rugged construction is required.

Specialized Grilles

Specialized Grille Products (continued)

S301 / S300 (FL,FS)

US301 / US300 (FL, FS)

SINGLE/DOUBLE
DEFLECTION SPIRAL
GRILLES

SINGLE/DOUBLE
DEFLECTION SPIRAL
GRILLES

Mounts directly to duct,


eliminating need for duct taps.
Radius end cap design to
match duct diameter.
Aluminum construction.
Individually adjustable blades.

Mounts directly to duct,


eliminating need for duct taps.
Universal end cap design can be
used on multiple duct diameters.
Aluminum construction.
Individually adjustable blades.

S8F

US8F

PERFORATED SPIRAL
GRILLE

PERFORATED SPIRAL
GRILLE

Radius end cap design to


match duct diameter.
Mounts directly to duct,
eliminating need for duct taps.
Aluminum construction.
Perforated face, 51% free area.

Universal end cap design can be


used on multiple duct diameters.
Mounts directly to duct,
eliminating need for duct taps.
Aluminum construction.
Perforated face, 51% free area.

www.titus-hvac.com | www.titus-energysolutions.com

SPIRAL DUCT MOUNTED GRILLES

pages: I35-I42

DOOR GRILLES

pages: I44-I47

CT-700 (L, S)

DOOR GRILLE

DOOR GRILLE

Steel construction.
Great for use in doors or partitions.
Sight proof design with large free area.
Optional auxiliary frame to facilitate mounting.

Aluminum construction.
Great for use in doors or partitions.
Sight proof design with large free area.
Optional auxiliary frame to facilitate mounting.

SPECIALIZED GRILLES

T-700 (L, S)

I7

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

Specialized Grille Products (continued)

1700 (L, S)
NARROW BLADE GRILLES



Extruded aluminum construction.


Reversible core for 5B or 15B deflection.
Core easily removes using a detachable lever.
Available with rear deflection blades.

SPECIALIZED GRILLES

pages: I52-I56

I8

REVERSIBLE CORE GRILLES

pages: I48-I51

COMMERCIAL / INDUSTRIAL LOUVERED SUPPLY GRILLES

JFA (L/S)
POLE OPERATED GRILLES




Steel & aluminum construction.


Individually adjustable aluminum front blades.
Steel rear blades are gang operated.
Pole operated rear blades ganged for easy adjustment.
Extruded aluminum front blades individually adjustable.

Specialized Grilles

Specialized Grille Products (continued)

DL
DRUM LOUVER
High capacity with long throws.
Adjustable vertical blades
mounted in rotating drum.
Aluminum construction.
Great for large open areas
where air must be discharged
over a large distance.

DL-SV

US-DL

US-DL-SV

DRUM LOUVER - SPLIT


VANE

SPIRAL DUCT DRUM


LOUVER

SPIRAL DUCT DRUM


LOUVER - SPLIT VANE

Split vane design for


increased flexibility.
High capacity with long throws.
Adjustable vertical blades
mounted in rotating drum.
Great for large open areas
where air must be discharged
over a large distance.

Mounts directly to duct,


eliminating need for duct taps.
Universal end cap design can be
used on multiple duct diameters.
High capacity with long throws,
great for large open areas.
Adjustable vertical blades
mounted in rotating drum.

Mounts directly to duct,


eliminating need for duct taps.
Universal end cap design can be
used on multiple duct diameters.
Split vane design for
increased flexibility.
Adjustable vertical blades
mounted in rotating drum.

www.titus-hvac.com | www.titus-energysolutions.com

DRUM LOUVERS

pages: I57-I64

SPECIALIZED GRILLES
I9

www.titus-hvac.com | www.titus-energysolutions.com

Overview

SPECIALIZED GRILLES

I10
I10

Titus offers a complete line of specialty grilles for the various


types of nonstandard applications that require special air
distribution products. Titus specialty grilles are designed to
provide the highest degree of quality and performance. The
comprehensive line includes:
Perforated and eggcrate return grilles
to match the look and feel of perforated
diffusers or parabolic lighting fixtures.
Heavy duty supply and return grilles for
rugged applications like gymnasiums.
Transfer and door grilles with sight proof design.
Narrow blade reversible core grilles.
High capacity drum louvers in single or split vane design.
Spiral mount grilles designed to mount directly onto
spiral ductwork without the need for saddle taps.
Heavy gauge supply grilles with lever
operator for industrial applications.

Specialized Grilles

Specialized Grilles

Overview (continued)

Supply

Front Blades
Horizontal
Vertical
1700L (For Double Deflection 1700S (For Double Deflection
use 1700L-07)
use 1700S-07)

Description

Deflection

Blade Spacing

Reversible Core Narrow Blade

15Up, 15 Down,
5 Up, or 5 Down

Narrow

Gang Operated Rear Blades Using Pole

Double

Front
1 Rear

JFA-L

JFA-S

High Capacity, Long Throw Commercial/


Industrial Grille in Rotating Drum

Single

Varies with Model

DL

Spiral Duct Grille - Radius Endcap


Spiral Duct Grille - Radius Endcap
Spiral Duct Grille - Universal Endcap
Spiral Duct Grille - Universal Endcap

Double
Single
Double
Single

S300FL
S301FL
US300FL
US301FL

S300FS
S301FS
US300FS
US301FS

Eggcrate Return

0
N/A

50F/50RSS

50F/50R/50RSS

Perforated Return

N/A

x x grid
x x 1 grid
1 x 1 x 1 grid
3
/16 Holes on

8F/8R/8SS

8F/8R/8SS

30RL
60FL
33RL
63FL
T-700
CT-700
50FF

30RS
60FS
33RS
63FS
N/A
N/A
50FF

8FF/ 8RF

8FF/ 8RF

30RFL
33RFL

30RFS
33RFS

S8F

S8F

US8F

US8F

Steel Door Grille


Aluminum Door Grille
Eggcrate Filter Grille*

0
0
38
30
Sight Proof
Sight Proof
N/A

Perforated Filter Grille*

Gym Filter Grille*

0
38

Spiral Duct Grille - Radius end caps

Perforated

Spiral Duct Grille - Universal end caps

Perforated

Heavy Duty Gym Grille

Return

Available
Material
Types
A
S
SS
SA

1700

1700-07

JFA

Supply
DL S300

staggered centers

x x grid
3
/16 Holes on
staggered centers

/16 Holes on
staggered centers
3
/16 Holes on
staggered centers
3

Model
S301

US300

US301

50 8

CT-700

30

33

Return
T-700 30

33

60 63

S8

www.titus-hvac.com | www.titus-energysolutions.com

Function

I
US8

Note: A = Aluminum Border and Blades, S = Steel, SS = 304 Stainless Steel, SA = Steel Border with Aluminum Blades or Core.
Some aluminum and stainless steel models may be constructed of all nonmagnetic components (no plastics) to meet MRI
requirements. Consult your Titus representative for specific details. See individual model information for construction details.
Titus reserves the right to make product improvements on a continual basis. As products are updated, new submittal sheets are
published. Your Titus representative can provide you with updated technical information on all products.

SPECIALIZED GRILLES
I11

Specialized Grilles

Available Models:

50F

Aluminum Border &


Core


50F-NT

Aluminum Border &


Core - Narrow Tee


50R

Steel Border with


Aluminum Core

50F
Aluminum border.
x x -inch aluminum core.
High free area core.
Minimized pressure drop.
Matches general appearance of
parabolic lighting fixtures.
MRI compatible

Products Include:
Standard Finish - #26 White.
Standard Core
x x inch.
Optional Cores: (50F, 50F-NT)
x x 1 inch
1 x 1 x 1inch
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Border Types:
#1 - Surface Mount
#3 - Lay-In
#7 - Channel Frame (50F only)
#8 - Core Only (50F only)
Optional Steel or Aluminum
Opposed-Blade Damper.

50F-NT

50F, 50F-NT
50F

www.titus-hvac.com | www.titus-energysolutions.com

Eggcrate Return Grilles

50R
Aluminum border.
x x -inch aluminum core.
Can be used in fire-rated
applications.
50F-NT
Same as 50F but designed to fit in
Narrow Tee Ceiling Grids.

50F Border Type 1


D plus 1"
D minus "
1"

"

Aluminum Core

Optional
Opposed
Blade
Damper

D minus "
Nominal Duct Size D"

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.

AVAILABLE SIZES
Model

Dimensions

50F

J
K

x x
1
2

Core Dimensions
x x 1
1
215/16

1x1x1
1
215/16

50F-NT
24"

50F, 50F-NT

D minus "

Optional
Opposed
Blade Damper

5/16"

9/16"

D minus "
23 "
23"

I12
I12

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

Specialized Grilles

Eggcrate Return Grilles (continued)

Stainless Steel

Products Include:
Standard Finish - #04 Mill.
Standard Core
x x -inch.
Countersunk Screw Holes.
#8 x 1 -inch long Phillips Flat Head Sheet
Metal Screws, Painted White.
Optional Stainless Steel Opposed-Blade Damper.

50R-SS

Available Model:

50R-SS

50R-SS
Stainless steel border.
x x -inch stainless
steel core.
High free area core.
Minimized pressure drop.
Matches general appearance of parabolic lighting
fixtures.
Available in 304 Stainless Steel (standard) and 316
Stainless Steel (optional).

www.titus-hvac.com | www.titus-energysolutions.com

50R-SS

50R-SS - Border Type 1

Available sizes (D x D) are 6 x 4 inches through 48 x 48 inches in 1-inch increments.


Odd and fractional sizes are available at additional cost.

50R-SS

All dimensions are in inches.

I13

Specialized Grilles

50FF
FILTER RETURN
Available Model:

50FF

Aluminum Border & Core - Filter Frame

Products Include:
x x -inch Aluminum Eggcrate Core.
1 inch Filter Frame.
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#3 - Lay-In
Hidden Screw Holes
Filter by Others.

For Performance Data, please refer to page I15.

50FF

www.titus-hvac.com | www.titus-energysolutions.com

Eggcrate Return Grilles (continued)

50FF
Aluminum border and filter frame.
x x -inch aluminum core.
High free area core.
Minimized pressure drop.
Matches model 50F in appearance.

Please refer to page I68


for Hinge Locations

50FF - Border Type 1 & 3


FASTENER
7/16

HINGE
D PLUS 3 3/4"
1/2

1 1/4

2" FOR 1" FILTER


3 1/8" FOR 2" FILTER
NOMINAL DUCT SIZE (D)
D PLUS 1/4"

I14
I14

D PLUS 3 3/4"

50FF

Duct opening should be nominal duct size (D) plus 1/4.


Side Cross-Sectional View:
Border Type 1 (Surface Mount) & Border Type 3 (Lay-in
T-Bar).
D PLUS
3 3/4"

All dimensions are in inches.

Specialized Grilles

PERFORMANCE DATA

Nominal Nominal Core


Duct
Duct
Area
Size
Area
sq. ft
( in. )
sq. ft
6x6
0.25
0.19
8x6

0.33

0.26

10x6

0.42

0.34

8x8

0.44

0.37

12x6

0.50

0.41

14x6

0.58

0.48

16x6
12x8

0.67

0.57

10x10

0.69

0.59

18x6
20x6
12x10

0.75

0.63

0.83

0.72

0.92

0.77

1.00

0.88

1.25

1.11

1.36

1.22

1.50

1.35

1.53

1.37

1.67

1.49

1.75
1.78

1.59
1.62

22x6
24x6
12x12
30x6
18x10
14x14
36x6
18x12
22x10
30x8
24x10
42x6
18x14
16x16

2.00

1.82

2.25

2.07

24x14

2.33

2.14

30x12

2.50

2.29

24x16

2.67

2.46

20x20

2.78

2.57

36x12

3.00

2.75

30x16
24x20

3.33

3.11

22x22
42x12
36x14

3.36

3.14

3.50

3.22

24x22

3.67

3.43

30x18

3.75

3.50

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

300
0.006
0.013
0.013
57
78
102
111
123
144
171
177
189
216
231
264
333
366
405
411
447
477
486
546
621
642
687
738
771
825
933
942
966
1029
1050
-

400
0.01
0.024
0.024
76
104
136
148
164
192
228
236
252
288
308
352
444
488
540
548
596
636
648
728
828
856
916
984
1028
1100
1244
1256
1288
1372
1400
-

500
0.016
0.037
0.037
95
130
170
185
205
240
285
295
315
360
385
440
555
610
675
685
745
795
810
910
1035
1070
1145
1230
1285
1375
1555
1570
1610
1715
1750
-

600
0.022
0.054
0.053
114
10
156
10
204
11
222
11
246
11
288
11
342
12
354
12
378
12
432
12
462
12
528
12
666
13
732
13
810
13
822
13
894
13
954
13
972
13
1092
13
1242
13
1284
13
1374
13
1476
13
1542
13
1650
14
1866
14
1884
14
1932
14
2058
14
2100
14

700
0.031
0.073
0.073
133
17
182
17
238
17
259
17
287
18
336
18
399
18
413
18
441
18
504
18
539
18
616
18
777
19
854
19
945
19
959
19
1043
19
1113
19
1134
19
1274
19
1449
19
1498
20
1603
20
1722
20
1799
20
1925
20
2177
20
2198
20
2254
20
2401
20
2450
20

800
0.04
0.096
0.095
152
22
208
22
272
23
296
23
328
23
384
23
456
23
472
23
504
24
576
24
616
24
704
24
888
24
976
24
1080
24
1096
25
1192
25
1272
25
1296
25
1456
25
1656
25
1712
25
1832
25
1968
25
2056
25
2200
25
2488
25
2512
25
2576
26
2744
26
2800
26

NC 40
1000
0.062
0.15
0.148
190
31
260
31
340
32
370
32
410
32
480
32
570
32
590
33
630
33
720
33
770
33
880
33
1110
34
1220
34
1350
34
1370
34
1490
34
1590
34
1620
34
1820
34
2070
34
2140
34
2290
34
2460
34
2570
34
2750
34
3110
35
3140
35
3220
35
3430
35
3500
35

1200
0.09
0.216
0.213
228
39
312
39
408
39
444
39
492
40
576
40
684
40
708
40
756
40
864
40
924
40
1056
40
1332
41
1464
41
1620
41
1644
41
1788
41
1908
41
1944
41
2184
41
2484
41
2568
42
2748
42
2952
42
3084
42
3300
42
3732
42
3768
42
3864
42
4116
42
4200
42

1400
0.122
0.294
0.29
266
45
364
45
476
46
518
46
574
46
672
46
798
46
826
46
882
46
1008
46
1078
47
1232
47
1554
47
1708
47
1890
47
1918
47
2086
47
2226
47
2268
48
2548
48
2898
48
2996
48
3206
48
3444
48
3598
48
3850
48
4354
48
4396
48
4508
48
4802
48
4900
48

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

24x12
18x16
18x18

Core Velocity
Velocity Pressure
1x1x1 Neg. Ps
xx Neg. Ps
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC

NC 20 NC 30

www.titus-hvac.com | www.titus-energysolutions.com

MODELS: 50F, 50F-NT, 50R, 50R-SS AND 50FF


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

I15

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

MODELS: 50F, 50F-NT, 50R, 50R-SS AND 50FF


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC 20 NC 30 NC 40
Nominal Nominal Core
Duct
Duct
Area
Size
Area
sq. ft
( in. )
sq. ft
48x12
24x24
4.00
3.75
36x18
36x20
30x24

4.50

4.22

5.00

4.71

42x18

5.25

4.94

28x28
42x20
30x28
48x18
36x24

5.44

5.16

5.83

5.51

6.00

5.66

30x30
42x24
36x28

6.25

5.94

7.00

6.66

46x22

7.03

6.68

32x32

7.11

6.78

36x30
48x24
36x32

7.50

7.16

8.00

7.63

34x34

8.03

7.68

36x34

8.50

8.14

42x30

8.75

8.38

36x36
42x34
48x30

9.00

8.63

10.00

9.60

38x38

10.03

9.64

42x36

10.50

10.10

46x34

10.86

10.45

42x38

11.08

10.67

40x40

11.11

10.70

48x36

12.00

11.57

42x42

12.25

11.82

44x44

13.44

12.99

48x42

14.00

13.54

46x46

14.69

14.22

48x46

15.33

14.85

48x48

16.00

15.50

Core Velocity
Velocity Pressure
1x1x1 Neg. Ps
xx Neg. Ps
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

I16
I16

300
0.006
0.013
0.013
1125
1266
1413
1482
1548
1653
1698
1782
1998
2004
2034
2148
2289
2304
2442
2514
2589
2880
2892
3030
3135
3201
3210
3471
3546
3897
4062
4266
4455
4650
-

400
0.01
0.024
0.024
1500
1688
1884
1976
2064
2204
2264
2376
2664
2672
2712
2864
3052
3072
3256
3352
3452
3840
3856
4040
4180
4268
4280
4628
4728
5196
5416
5688
5940
6200
-

500
0.016
0.037
0.037
1875
2110
2355
2470
2580
2755
2830
2970
3330
3340
3390
3580
3815
3840
4070
4190
4315
4800
4820
5050
5225
5335
5350
5785
5910
6495
6770
7110
7425
7750
-

600
0.022
0.054
0.053
2250
14
2532
14
2826
14
2964
14
3096
14
3306
14
3396
14
3564
15
3996
15
4008
15
4068
15
4296
15
4578
15
4608
15
4884
15
5028
15
5178
15
5760
15
5784
15
6060
15
6270
15
6402
15
6420
15
6942
15
7092
15
7794
16
8124
16
8532
16
8910
16
9300
16

700
0.031
0.073
0.073
2625
20
2954
20
3297
21
3458
21
3612
21
3857
21
3962
21
4158
21
4662
21
4676
21
4746
21
5012
21
5341
21
5376
21
5698
21
5866
21
6041
21
6720
21
6748
21
7070
22
7315
22
7469
22
7490
22
8099
22
8274
22
9093
22
9478
22
9954
22
10395
22
10850
22

800
0.04
0.096
0.095
3000
26
3376
26
3768
26
3952
26
4128
26
4408
26
4528
26
4752
26
5328
26
5344
26
5424
27
5728
27
6104
27
6144
27
6512
27
6704
27
6904
27
7680
27
7712
27
8080
27
8360
27
8536
27
8560
27
9256
27
9456
27
10392
27
10832
27
11376
27
11880
27
12400
28

1000
0.062
0.15
0.148
3750
35
4220
35
4710
35
4940
35
5160
35
5510
35
5660
35
5940
35
6660
36
6680
36
6780
36
7160
36
7630
36
7680
36
8140
36
8380
36
8630
36
9600
36
9640
36
10100
36
10450
36
10670
36
10700
36
11570
36
11820
36
12990
36
13540
37
14220
37
14850
37
15500
37

1200
0.09
0.216
0.213
4500
42
5064
42
5652
43
5928
43
6192
43
6612
43
6792
43
7128
43
7992
43
8016
43
8136
43
8592
43
9156
43
9216
43
9768
43
10056
43
10356
43
11520
43
11568
43
12120
44
12540
44
12804
44
12840
44
13884
44
14184
44
15588
44
16248
44
17064
44
17820
44
18600
44

1400
0.122
0.294
0.29
5250
49
5908
49
6594
49
6916
49
7224
49
7714
49
7924
49
8316
49
9324
49
9352
49
9492
49
10024
49
10682
49
10752
49
11396
50
11732
50
12082
50
13440
50
13496
50
14140
50
14630
50
14938
50
14980
50
16198
50
16548
50
18186
50
18956
50
19908
50
20790
50
21700
50

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

Specialized Grilles

SUGGESTED SPECIFICATIONS

Available Models:
50F
50R
50R-SS

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel, aluminum or 304 stainless steel.
Damper must be operable from the face of the grille.

Available Filter Return Model:


50FF

50F ALUMINUM GRID / ALUMINUM BORDER

Return grilles shall be Titus Model 50F for the sizes and
mounting types as shown on the plans and outlet schedule.
Return grilles must provide a free area of at least 90%.
Outer borders shall be constructed of heavy extruded
aluminum with a thickness of 0.040-0.050 inch and shall
have countersunk screw holes for a neat appearance.
Border width shall be 1 inches on all sides and shall be
interlocked at the four corners and mechanically staked to
form a rigid frame. Choice of three sizes of aluminum grid:
x x inch, x x 1 inch, or 1 x 1 x 1 inch shall
be available.
Optional opposed-blade volume damper shall be constructed
of heavy gauge steel or aluminum. Damper must be
operable from the face of the grille.

50R ALUMINUM GRID / STEEL BORDER

Return grilles shall be Titus Model 50R for sizes and


mounting types as shown on the plans and outlet schedule.
Return grilles must provide a free area of at least 90%.
Outer borders shall be constructed of steel and shall
have countersunk screw holes for a neat appearance.
Border width shall be 11/4 inches on all sides and shall be
interlocked at the four corners and mechanically staked to
form a rigid frame. The aluminum grid is x x -inch.

50R-SS STAINLESS STEEL GRID / STAINLESS STEEL


BORDER

Return grilles shall be Titus Model 50R-SS for sizes and


mounting types as shown on the plans and outlet schedule.

50FF ALUMINUM GRID AND BORDER WITH FILTER


FRAME

Return filter grilles shall be Titus Model 50FF for the sizes
and mounting types as shown on the plans and outlet
schedule. Return grilles must provide a free area of at least
90%.
Outer borders shall be constructed of heavy extruded
aluminum with a thickness of 0.040-0.050 inch and shall
have countersunk screw holes for a neat appearance.
Border width shall be 1 inches on all sides and shall be
interlocked at the four corners and mechanically staked
to form a rigid frame. Aluminum grid shall be x x
inch. Grille shall be provided with a filter frame for a
standard 1-inch filter to fit the specified duct size.

FINISH AND PERFORMANCE SPECIFICATIONS


(50F, 50R AND 50FF ONLY)

www.titus-hvac.com | www.titus-energysolutions.com

Return grilles must provide a free area of at least 90%.


Outer borders shall be 304 Stainless Steel. Screw holes shall
be countersunk for a neat appearance. Border width shall be
1 inches on all sides and shall be interlocked at the four
corners and mechanically staked to form a rigid frame. The
stainless steel grid is x x -inch.

EGGCRATE RETURN GRILLES

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION

Aluminum Border
Steel Border
Stainless Steel

XXX
Filter Frame
(optional)

Width

Border Type
Surface Mount

X
Height

1
White (std.)
Mill (Stainless
Steel)

XX
26
04
Finish

XX-XX-XX
Eggcrate Core
Std.
Optional
Optional

Optional
PF
PFA

Steel Plaster Frame


Aluminum Plaster
Frame
Stainless Steel Plaster
Frame

XxXxX
x x
xx1
1 x 1x 1

PF-SS
XX-XX

SPECIFICATIONS

Model
50F
50R
50R-SS

Optional
Damper (note1)
Steel
AG-15
Aluminum AG-15-AA
Stainless Steel AG-15-SS

I17

Specialized Grilles

8F, 8FF, 8R, 8RF, 8SS


Available Models:

8F Aluminum

8FF Aluminum Filter Return

8R Steel

8RF Steel Filter Return

8SS 304 Stainless Steel
Products Include:
Standard Finish - #26 White (8F/8R,
8FF/8RF).
Standard Finish - #04 Mill (8SS).
Available Border Types
#1 - Surface Mount (All models)
#2 - Snap-In (8F)
#3 - Lay-In (8F, 8R, 8RF, 8FF)
#4 - Spline (8F)
Countersunk Screw Holes.
Optional Opposed Blade
Damper.

Please refer to page I68


for Hinge Locations

8FF, 8RF

8F, 8R, 8SS

www.titus-hvac.com | www.titus-energysolutions.com

Perforated Return Grilles

8FF, 8RF
Available for lay-in or surface
mounting applications.
For use with 1-inch thick filters.
Perforated screen with 3/16inch diameter holes on
inch staggered centers.
Matches general appearance
of industry standard
perforated diffusers.

8F, 8R, 8SS


Perforated screen with 3/16inch diameter holes on
inch staggered centers.
51% free area perforated face.
Matches general appearance
of industry standard
perforated diffusers.

8F, 8R - Border Type 1


D plus 1"
1"

D minus "

"

Optional
Opposed
Blade
Damper

1"
2"

D minus "
Nominal Duct Size D"

Available sizes (D x D) Border Type 1 are 6 x 4 inches through 48 x 48 inches in 2-inch


increments. Odd and fractional sizes are available at additional cost.

8F, 8FF, 8R, 8RF & 8SS

8FF, 8RF - Border Type 1 & 3

HINGE

FASTENER
D PLUS 3 3/4"
7/16

2" FOR 1" FILTER


3 1/8" FOR 2" FILTER
NOMINAL DUCT SIZE (D)
D PLUS 1/4"

Duct opening should be nominal duct size (D) plus 1/4.


Side Cross-Sectional View:
D PLUS 3 3/4"
Border Type 1 (Surface Mount) & Border Type 3 (Lay-in T-Bar).

I18
I18

1 1/4

All dimensions are in inches.

Specialized Grilles

PERFORMANCE DATA

NC 10

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC 30 NC 40

600
700 800 1000 1200 1400
0.031 0.040 0.062 0.090 0.122 0.12
0.156 0.203 0.318 0.458 0.623 0.62
114
156
204
11
222
12
246
12
288
13
342
14
354
14
378
14
432
15
462
15
528
15
666
16
732
17
810
17
822
17
894
18
954
18
972
18
1092
19
1242
19
1284
19
1374
20
1476
20
1542
20
1650
20
1866
21
1884
21
1932
21
2058
21
2100
21

133
13
182
14
238
15
259
15
287
16
336
17
399
17
413
18
441
18
504
18
539
19
616
19
777
20
854
21
945
21
959
21
1043
22
1113
22
1134
22
1274
22
1449
23
1498
23
1603
23
1722
24
1799
24
1925
24
2177
25
2198
25
2254
25
2401
25
2450
25

152
16
208
17
272
18
296
19
328
19
384
20
456
21
472
21
504
21
576
22
616
22
704
23
888
24
976
24
1080
24
1096
24
1192
25
1272
25
1296
25
1456
26
1656
26
1712
26
1832
27
1968
27
2056
27
2200
27
2488
28
2512
28
2576
28
2744
28
2800
29

190
21
260
23
340
24
370
24
410
25
480
25
570
26
590
26
630
27
720
27
770
27
880
28
1110
29
1220
29
1350
30
1370
30
1490
30
1590
31
1620
31
1820
31
2070
32
2140
32
2290
32
2460
32
2570
33
2750
33
3110
33
3140
34
3220
34
3430
34
3500
34

228
26
312
27
408
28
444
29
492
29
576
30
684
31
708
31
756
31
864
32
924
32
1056
32
1332
33
1464
34
1620
34
1644
34
1788
35
1908
35
1944
35
2184
36
2484
36
2568
36
2748
37
2952
37
3084
37
3300
37
3732
38
3768
38
3864
38
4116
38
4200
38

266
30
364
31
476
32
518
33
574
33
672
34
798
34
826
35
882
35
1008
35
1078
36
1232
36
1554
37
1708
38
1890
38
1918
38
2086
39
2226
39
2268
39
2548
39
2898
40
2996
40
3206
40
3444
41
3598
41
3850
41
4354
42
4396
42
4508
42
4802
42
4900
42

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

Nominal Nominal Core


Core Velocity
300
400
500
Duct
Duct
Area
Velocity Pressure
0.010 0.016 0.022
Size
Area
sq. ft Neg. Static Pressure 0.051 0.079 0.114
( in. )
sq. ft
6x6
0.25
0.19
Airflow, cfm
57
76
95
NC
8x6
0.33
0.26
Airflow, cfm
78
104
130
NC
10x6
0.42
0.34
Airflow, cfm
102
136
170
NC
8x8
0.44
0.37
Airflow, cfm
111
148
185
NC
12x6
0.5
0.41
Airflow, cfm
123
164
205
NC
14x6
0.58
0.48
Airflow, cfm
144
192
240
NC
16x6
Airflow, cfm
171
228
285
12x8
0.67
0.57
NC
Airflow, cfm
177
236
295
10x10
0.69
0.59
NC
Airflow, cfm
189
252
315
18x6
0.75
0.63
NC
20x6
Airflow, cfm
216
288
360
12x10
0.83
0.72
NC
Airflow, cfm
231
308
385
22x6
0.92
0.77
NC
24x6
Airflow, cfm
264
352
440
12x12
1
0.88
NC
11
30x6
Airflow, cfm
333
444
555
18x10
1.25
1.11
NC
12
Airflow, cfm
366
488
610
14x14
1.36
1.22
NC
12
36x6
Airflow, cfm
405
540
675
18x12
1.5
1.35
NC
13
Airflow, cfm
411
548
685
22x10
1.53
1.37
NC
13
30x8
Airflow, cfm
447
596
745
24x10
1.67
1.49
NC
13
42x6
Airflow, cfm
477
636
795
18x14
1.75
1.59
NC
14
16x16
1.78
1.62
Airflow, cfm
486
648
810
NC
14
24x12
2
1.82
Airflow, cfm
546
728
910
18x16
NC
14
18x18
2.25
2.07
Airflow, cfm
621
828
1035
NC
15
24x14
2.33
2.14
Airflow, cfm
642
856
1070
NC
15
30x12
2.5
2.29
Airflow, cfm
687
916
1145
NC
15
24x16
2.67
2.46
Airflow, cfm
738
984
1230
NC
15
20x20
2.78
2.57
Airflow, cfm
771 1028 1285
NC
16
36x12
3
2.75
Airflow, cfm
825 1100 1375
NC
16
30x16
3.33
3.11
Airflow, cfm
933
1244 1555
24x20
NC
11
16
Airflow, cfm
942
1256 1570
22x22
3.36
3.14
NC
11
17
42x12
Airflow, cfm
966
1288 1610
36x14
3.5
3.22
NC
11
17
Airflow, cfm
1029 1372 1715
24x22
3.67
3.43
NC
11
17
Airflow, cfm
1050 1400 1750
30x18
3.75
3.5
NC
12
17

NC 20

www.titus-hvac.com | www.titus-energysolutions.com

MODELS: 8F, 8FF, 8R, 8RF, AND 8SS


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

I19

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

I20

MODELS: 8F, 8FF, 8R, 8RF, AND 8SS


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC 10

NC 20

Nominal Nominal Core


Core Velocity
300
400 500
Duct
Duct
Area
Velocity Pressure
0.006 0.010 0.016
Size
Area
sq. ft Neg. Static Pressure 0.029 0.051 0.079
( in. )
sq. ft
48x12
Airflow, cfm
1125 1500 1875
24x24
4.00
3.75
NC
12
17
Airflow, cfm
1266 1688 2110
36x18
4.50
4.22
NC
12
18
36x20
Airflow, cfm
1413 1884 2355
30x24
5.00
4.71
NC
13
18
Airflow, cfm
1482 1976 2470
42x18
5.25
4.94
NC
13
18
Airflow, cfm
1548 2064 2580
28x28
5.44
5.16
NC
13
19
42x20
Airflow, cfm
1653 2204 2755
30x28
5.83
5.51
NC
13
19
48x18
Airflow, cfm
1698 2264 2830
36x24
6.00
5.66
NC
14
19
Airflow, cfm
1782 2376 2970
19
30x30
6.25
5.94
NC
14
42x24
Airflow, cfm
1998 2664 3330
36x28
7.00
6.66
NC
14
20
Airflow, cfm
2004 2672 3340
46x22
7.03
6.68
NC
14
20
Airflow, cfm
2034 2712 3390
32x32
7.11
6.78
NC
14
20
Airflow, cfm
2148 2864 3580
36x30
7.50
7.16
NC
15
20
48x24
Airflow, cfm
2289 3052 3815
36x32
8.00
7.63
NC
15
20
Airflow, cfm
2304 3072 3840
34x34
8.03
7.68
NC
15
20
Airflow, cfm
2442 3256 4070
36x34
8.50
8.14
NC
15
21
Airflow, cfm
2514 3352 4190
42x30
8.75
8.38
NC
15
21
Airflow, cfm
2589 3452 4315
36x36
9.00
8.63
NC
15
21
42x34
Airflow, cfm
2880 3840 4800
48x30
10.00
9.60
NC
16
21
Airflow, cfm
2892 3856 4820
38x38
10.03
9.64
NC
16
21
Airflow, cfm
3030 4040 5050
42x36
10.50
10.10
NC
16
22
Airflow, cfm
3135 4180 5225
46x34
10.86
10.45
NC
16
22
Airflow, cfm
3201 4268 5335
42x38
11.08
10.67
NC
16
22
Airflow, cfm
3210 4280 5350
40x40
11.11
10.70
NC
16
22
Airflow, cfm
3471 4628 5785
48x36
12.00
11.57
NC
17
22
Airflow, cfm
3546 4728 5910
42x42
12.25
11.82
NC
17
22
Airflow, cfm
3897 5196 6495
44x44
13.44
12.99
NC
17
23
Airflow, cfm
4062 5416 6770
48x42
14.00
13.54
NC
17
23
Airflow, cfm
4266 5688 7110
46x46
14.69
14.22
NC
11
18
23
Airflow, cfm
4455 5940 7425
48x46
15.33
14.85
NC
11
18
23
Airflow, cfm
4650 6200 7750
48x48
16.00
15.50
NC
11
18
23

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC 30

NC 40

600
700
800 1000 1200 1400
0.022 0.031 0.040 0.062 0.090 0.122
0.114 0.156 0.203 0.318 0.458 0.623
2250
22
2532
22
2826
23
2964
23
3096
23
3306
23
3396
24
3564
24
3996
24
4008
24
4068
24
4296
25
4578
25
4608
25
4884
25
5028
25
5178
25
5760
26
5784
26
6060
26
6270
26
6402
26
6420
26
6942
27
7092
27
7794
27
8124
27
8532
28
8910
28
9300
28

2625
26
2954
26
3297
27
3458
27
3612
27
3857
27
3962
27
4158
28
4662
28
4676
28
4746
28
5012
28
5341
29
5376
29
5698
29
5866
29
6041
29
6720
30
6748
30
7070
30
7315
30
7469
30
7490
30
8099
30
8274
31
9093
31
9478
31
9954
31
10395
32
10850
32

3000
29
3376
29
3768
30
3952
30
4128
30
4408
30
4528
31
4752
31
5328
31
5344
31
5424
31
5728
32
6104
32
6144
32
6512
32
6704
32
6904
32
7680
33
7712
33
8080
33
8360
33
8536
33
8560
33
9256
34
9456
34
10392
34
10832
34
11376
35
11880
35
12400
35

3750
34
4220
35
4710
35
4940
36
5160
36
5510
36
5660
36
5940
36
6660
37
6680
37
6780
37
7160
37
7630
37
7680
37
8140
38
8380
38
8630
38
9600
38
9640
38
10100
39
10450
39
10670
39
10700
39
11570
39
11820
39
12990
40
13540
40
14220
40
14850
40
15500
40

4500
39
5064
39
5652
40
5928
40
6192
40
6612
40
6792
41
7128
41
7992
41
8016
41
8136
41
8592
42
9156
42
9216
42
9768
42
10056
42
10356
42
11520
43
11568
43
12120
43
12540
43
12804
43
12840
43
13884
44
14184
44
15588
44
16248
44
17064
45
17820
45
18600
45

5250
43
5908
43
6594
44
6916
44
7224
44
7714
44
7924
44
8316
45
9324
45
9352
45
9492
45
10024
45
10682
46
10752
46
11396
46
11732
46
12082
46
13440
47
13496
47
14140
47
14630
47
14938
47
14980
47
16198
47
16548
48
18186
48
18956
48
19908
48
20790
49
21700
49

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

Specialized Grilles

SUGGESTED SPECIFICATIONS

Available Models:
8R/8F/8SS
Available Perforated Filter Return Grille Models:
8RF/8FF

8SS 304 STAINLESS STEEL

8R STEEL / 8RF STEEL WITH FILTER FRAME

Return filter grilles shall be Titus Model 8R or 8RF for


the sizes and mounting types as shown on the plans and
outlet schedule. The face and border shall be constructed
of perforated steel with 3/16-inch diameter holes on
inch staggered centers to provide 51 percent free area.
Outer borders shall be 1 inches wide. Corners shall be
assembled with full penetration resistance welds with a
reinforcing patch for extra strength. Screw holes shall be
countersunk for a neat appearance. For Model 8RF: Grille
shall be provided with a filter frame for a standard 1-inch
filter to fit the specified duct size.

8F ALUMINUM / 8FF ALUMINUM WITH FILTER FRAME


Return filter grilles shall be Titus Model 8F or 8FF for the
sizes and mounting types as shown on the plans and outlet
schedule. The face shall be constructed of perforated
aluminum with 3/16 -inch diameter holes on -inch
staggered centers to provide 51 percent free area.
Outer borders shall be constructed of heavy extruded
aluminum with a thickness of 0.040-0.050 inch and shall
have countersunk screw holes for a neat appearance.

Return filter grilles shall be Titus Model 8SS for the sizes and
mounting types as shown on the plans and outlet schedule.
The face and border shall be constructed of 304 stainless
steel with 3/16-inch diameter holes on -inch staggered
centers to provide 51 percent free area. Outer borders shall
be 13/16 inches wide. Corners shall be assembled with full
penetration resistance welds with a reinforcing patch for
extra strength. Screw holes shall be countersunk for a neat
appearance.

FINISH AND PERFORMANCE SPECIFICATIONS

The grille finish shall be #26 white for 8R, 8RF, 8F and
8FF. The finish shall be an anodic acrylic paint, baked at
315 F for 30 minutes. The pencil hardness must be HB to
H. The paint must pass a 100-hour ASTM B117 Corrosive
Environments Salt Spray Test without creepage, blistering or
deterioration of film. The paint must pass a 250-hour ASTM
D870 Water Immersion Test. The paint must also pass the
ASTM D2794 Reverse Impact Cracking Test with a 50-inch
pound force applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

www.titus-hvac.com | www.titus-energysolutions.com

Border width shall be 1 inches on all sides and shall be


interlocked at the four corners and mechanically staked to
form a rigid frame. For Model 8FF: Grille shall be provided
with a filter frame for a standard 1-inch filter to fit the
specified duct size.

PERFORATED RETURN GRILLES

MODEL NUMBER SPECIFICATION


Model
8R
8F
8SS

Width

Steel
Aluminum

Border Type

304 Stainless Steel

XXX
Filter Frame

Surface Mount

X
Height

(optional)

1
White (std.)
Mill (Stainless
Steel only)

Optional
Damper (note)
Steel
AG-15
Aluminum AG-15-AA
Stainless Steel AG-15-SS
XX
26
04
Finish

XXX

Steel Plaster
Frame

PF

Aluminum Plaster
Frame

PFA

Stainless Steel
Plaster Frame

PFS

Optional

SPECIFICATIONS

Note: 8SS not available with filter frame.

XX-XX-XX

I21

Specialized Grilles

33(RL, RS), 30(RL, RS)


30(RL, RS)

GRILLES - STEEL
33(RL, RS)

www.titus-hvac.com | www.titus-energysolutions.com

Heavy Duty Bar Return Grilles

Available 38B Deflection Models:


33RL
33RS

Available 0B Deflection Models:
30RL
30RS
Products Include:
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1 inch long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Steel Opposed Blade Damper.

33RL
-inch blade spacing.
38 fixed deflection.
16-gauge border,
14-gauge blades.
Support bars 6 inches on center.
Blades parallel to the
long dimension.
33RS
Same as 33RL with blades
parallel to the short dimension.

30RL
-inch blade spacing.
0 fixed deflection.
16-gauge border,
14-gauge blades.
Support bars 6 inches on center.
Blades parallel to the
long dimension.
30RS
Same as 30RL with blades
parallel to the short dimension.

38B Deflection Models 33RL/RS - Border Type 1


D plus 1"
D minus "
1"

"

"

Optional
Opposed
Blade
Damper

1"

2"

D minus "
Nominal Duct Size D"

33(RL, RS), 30(RL, RS)

Available sizes (D x D) Border Type 1 are 6 x 4 inches through 48 x 48 inches in 1-inch


increments. Odd and fractional sizes are available at additional cost.
0B Deflection Models 30RL/RS Border Type 1
D plus 1"
1"

D minus "

"

"

Optional
Opposed
Blade
Damper

1"

D minus "
Nominal Duct Size D"

Available sizes (D x D) Border Type 1 are 6 x 4 inches through 48 x 48 inches in 1-inch


increments. Odd and fractional sizes are available at additional cost.

I22

All dimensions are in inches.

2"

Specialized Grilles

Heavy Duty Bar Return Grilles (continued)

Available 38B Deflection Models:


33RFL
33RFS

Available 0B Deflection Models:
30RFL
30RFS

30RFL
Same as model 30RL, on page
L16, with 1-inch filter frame.
30RFS
Same as 30RS, on page L16,
with 1-inch filter frame.

33RFL
Same as model 33RL, on page
L16, with 1-inch filter frame.
33RFS
Same as 33RS, on page L16,
with 1-inch filter frame.

Products Include:
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Hidden Screw Holes.
#8 x 1 inch long Phillips Flat Head
Sheet Metal Screws, Painted White.
Filter by Others.
Extruded Aluminum Filter Frame.

30(RFL, RFS)

33(RFL, RFS)

GRILLES - STEEL

38B Deflection Models 33RFL/RFS - Border Type 1


FASTENER

For Performance Data, please refer to page


I24 for base model and add pressure drop to
the installed filter.

7/16

HINGE

D PLUS 3 3/4"
1/2

www.titus-hvac.com | www.titus-energysolutions.com

33(RFL, RFS), 30(RFL, RFS)

1 1/4

2 5/32" FOR 1" FILTER


3 3/16" FOR 2" FILTER

Please refer to page I68


for Hinge Locations

NOMINAL DUCT SIZE (D)


D PLUS 1/4"

Duct opening should be nominal duct size (D) plus 1/4.


Side Cross-Sectional View:
Border Type 1 (Surface Mount).
D PLUS 3 3/4"

FASTENER

HINGE

D PLUS 3 3/4"
3/8

7/16

1 1/4

D PLUS 3 3/4"

2 5/32" FOR 1" FILTER


3 3/16" FOR 2" FILTER
NOMINAL DUCT SIZE (D)
D PLUS 1/4"

33(RFL, RFS), 30(RFL, RFL)

0B Deflection Models 30RFL/RFS - Border Type 1

Duct opening should be nominal duct size (D) plus 1/4.


Side Cross-Sectional View:
Border Type 1 (Surface Mount).
D PLUS 3 3/4"

All dimensions are in inches.

I23

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

33R RETURN -INCH SPACING 38B DEFLECTION


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

NC 10 NC 20

Nominal Nominal Core


Core Velocity
200
300
400
Duct
Duct
Area
Velocity Pressure
0.002 0.006 0.010
Size
Area
sq. ft Neg. Static Pressure 0.010 0.023 0.040
( in. )
sq. ft
6x6
0.25
0.19
Airflow, cfm
38
57
76
NC
8x6
0.33
0.26
Airflow, cfm
52
78
104
NC
10x6
0.42
0.34
Airflow, cfm
68
102
136
NC
8x8
0.44
0.37
Airflow, cfm
74
111
148
NC
12x6
0.50
0.41
Airflow, cfm
82
123
164
NC
14x6
0.58
0.48
Airflow, cfm
96
144
192
NC
11
16x6
Airflow, cfm
114
171
228
12x8
0.67
0.57
NC
12
Airflow, cfm
118
177
236
10x10
0.69
0.59
NC
12
Airflow, cfm
126
189
252
18x6
0.75
0.63
NC
12
20x6
Airflow, cfm
144
216
288
13
12x10
0.83
0.72
NC
Airflow, cfm
154
231
308
22x6
0.92
0.77
NC
13
24x6
Airflow, cfm
176
264
352
12x12
1.00
0.88
NC
14
30x6
Airflow, cfm
222
333
444
18x10
1.25
1.11
NC
15
Airflow, cfm
244
366
488
14x14
1.36
1.22
NC
15
36x6
Airflow, cfm
270
405
540
18x12
1.50
1.35
NC
16
Airflow, cfm
274
411
548
22x10
1.53
1.37
NC
16
30x8
Airflow, cfm
298
447
596
24x10
1.67
1.49
NC
16
42x6
Airflow, cfm
318
477
636
18x14
1.75
1.59
NC
16
16x16
1.78
1.62
Airflow, cfm
324
486
648
NC
16
24x12
2.00
1.82
Airflow, cfm
364
546
728
18x16
NC
17
18x18
2.25
2.07
Airflow, cfm
414
621
828
NC
18
24x14
2.33
2.14
Airflow, cfm
428
642
856
NC
18
30x12
2.50
2.29
Airflow, cfm
458
687
916
NC
18
24x16
2.67
2.46
Airflow, cfm
492
738
984
NC
18
20x20
2.78
2.57
Airflow, cfm
514
771
1028
NC
18
36x12
3.00
2.75
Airflow, cfm
550
825
1100
NC
19
30x16
3.33
3.11
Airflow, cfm
622
933
1244
24x20
NC
19
Airflow, cfm
628
942
1256
22x22
3.36
3.14
NC
19
42x12
Airflow, cfm
644
966
1288
19
36x14
3.50
3.22
NC
Airflow, cfm
686 1029 1372
24x22
3.67
3.43
NC
20
Airflow, cfm
700 1050 1400
30x18
3.75
3.50
NC
20

NC 30

NC 40

500
600 700
800
900 1000
0.016 0.022 0.031 0.040 0.050 0.062
0.063 0.090 0.123 0.161 0.203 0.251
95
14
130
16
170
17
185
17
205
18
240
18
285
19
295
19
315
20
360
20
385
20
440
21
555
22
610
22
675
23
685
23
745
23
795
24
810
24
910
24
1035
25
1070
25
1145
25
1230
26
1285
26
1375
26
1555
27
1570
27
1610
27
1715
27
1750
27

114
20
156
22
204
23
222
23
246
24
288
24
342
25
354
25
378
26
432
26
462
26
528
27
666
28
732
28
810
29
822
29
894
29
954
30
972
30
1092
30
1242
31
1284
31
1374
31
1476
31
1542
32
1650
32
1866
33
1884
33
1932
33
2058
33
2100
33

133
25
182
27
238
28
259
28
287
29
336
29
399
30
413
30
441
31
504
31
539
31
616
32
777
33
854
33
945
34
959
34
1043
34
1113
35
1134
35
1274
35
1449
36
1498
36
1603
36
1722
37
1799
37
1925
37
2177
38
2198
38
2254
38
2401
38
2450
38

152
30
208
31
272
32
296
33
328
33
384
34
456
35
472
35
504
35
576
36
616
36
704
36
888
37
976
38
1080
38
1096
38
1192
39
1272
39
1296
39
1456
40
1656
40
1712
40
1832
41
1968
41
2056
41
2200
41
2488
42
2512
42
2576
42
2744
42
2800
42

171
34
234
35
306
36
333
37
369
37
432
38
513
38
531
39
567
39
648
39
693
40
792
40
999
41
1098
42
1215
42
1233
42
1341
43
1431
43
1458
43
1638
43
1863
44
1926
44
2061
44
2214
45
2313
45
2475
45
2799
46
2826
46
2898
46
3087
46
3150
46

190
37
260
38
340
40
370
40
410
40
480
41
570
42
590
42
630
42
720
43
770
43
880
44
1110
45
1220
45
1350
46
1370
46
1490
46
1590
46
1620
46
1820
47
2070
47
2140
48
2290
48
2460
48
2570
48
2750
49
3110
49
3140
49
3220
49
3430
50
3500
50

NC 50

I24

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

Specialized Grilles

PERFORMANCE DATA

NC 10 NC 20

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC 40

NC 50

500
600 700
800 900 1000
0.016 0.022 0.031 0.040 0.050 0.062
0.063 0.090 0.123 0.161 0.203 0.251
1875
27
2110
28
2355
28
2470
29
2580
29
2755
29
2830
29
2970
29
3330
30
3340
30
3390
30
3580
30
3815
30
3840
30
4070
31
4190
31
4315
31
4800
31
4820
31
5050
32
5225
32
5335
32
5350
32
5785
32
5910
32
6495
33
6770
33
7110
33
7425
33
7750
34

2250
33
2532
34
2826
34
2964
35
3096
35
3306
35
3396
35
3564
35
3996
36
4008
36
4068
36
4296
36
4578
36
4608
36
4884
37
5028
37
5178
37
5760
37
5784
37
6060
38
6270
38
6402
38
6420
38
6942
38
7092
38
7794
39
8124
39
8532
39
8910
39
9300
39

2625
38
2954
39
3297
39
3458
40
3612
40
3857
40
3962
40
4158
40
4662
41
4676
41
4746
41
5012
41
5341
41
5376
41
5698
42
5866
42
6041
42
6720
42
6748
42
7070
43
7315
43
7469
43
7490
43
8099
43
8274
43
9093
44
9478
44
9954
44
10395
44
10850
45

3000
43
3376
43
3768
44
3952
44
4128
44
4408
44
4528
45
4752
45
5328
45
5344
45
5424
45
5728
46
6104
46
6144
46
6512
46
6704
46
6904
46
7680
47
7712
47
8080
47
8360
47
8536
47
8560
47
9256
48
9456
48
10392
48
10832
48
11376
49
11880
49
12400
49

3375
47
3798
47
4239
48
4446
48
4644
48
4959
48
5094
48
5346
49
5994
49
6012
49
6102
49
6444
49
6867
50
6912
50
7326
50
7542
50
7767
50
8640
51
8676
51
9090
51
9405
51
9603
51
9630
51
10413
51
10638
52
11691
52
12186
52
12798
52
13365
53
13950
53

3750
50
4220
51
4710
51
4940
51
5160
51
5510
52
5660
52
5940
52
6660
52
6680
53
6780
53
7160
53
7630
53
7680
53
8140
53
8380
53
8630
54
9600
54
9640
54
10100
54
10450
54
10670
55
10700
55
11570
55
11820
55
12990
55
13540
56
14220
56
14850
56
15500
56

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

Nominal Nominal Core


Core Velocity
200
300
400
Duct
Duct
Area
Velocity Pressure
0.002 0.006 0.010
Size
Area
sq. ft Neg. Static Pressure 0.010 0.023 0.040
( in. )
sq. ft
48x12
Airflow, cfm
750
1125 1500
24x24
4.00
3.75
NC
11
20
Airflow, cfm
844
1266 1688
36x18
4.50
4.22
NC
11
21
36x20
Airflow, cfm
942
1413 1884
30x24
5.00
4.71
NC
12
21
Airflow, cfm
988
1482 1976
42x18
5.25
4.94
NC
12
21
Airflow, cfm
1032 1548 2064
28x28
5.44
5.16
NC
12
21
42x20
Airflow, cfm
1102 1653 2204
30x28
5.83
5.51
NC
12
22
48x18
Airflow, cfm
1132 1698 2264
36x24
6.00
5.66
NC
12
22
Airflow, cfm
1188 1782 2376
30x30
6.25
5.94
NC
13
22
42x24
Airflow, cfm
1332 1998 2664
36x28
7.00
6.66
NC
13
23
Airflow, cfm
1336 2004 2672
46x22
7.03
6.68
NC
13
23
Airflow, cfm
1356 2034 2712
32x32
7.11
6.78
NC
13
23
Airflow, cfm
1432 2148 2864
36x30
7.50
7.16
NC
14
23
48x24
Airflow, cfm
1526 2289 3052
36x32
8.00
7.63
NC
14
23
Airflow, cfm
1536 2304 3072
34x34
8.03
7.68
NC
14
23
Airflow, cfm
1628 2442 3256
36x34
8.50
8.14
NC
14
23
Airflow, cfm
1676 2514 3352
42x30
8.75
8.38
NC
14
24
Airflow, cfm
1726 2589 3452
36x36
9.00
8.63
NC
14
24
42x34
Airflow, cfm
1920 2880 3840
48x30
10.00
9.60
NC
15
24
Airflow, cfm
1928 2892 3856
38x38
10.03
9.64
NC
15
24
Airflow, cfm
2020 3030 4040
42x36
10.50
10.10
NC
15
24
Airflow, cfm
2090 3135 4180
46x34
10.86
10.45
NC
15
25
Airflow, cfm
2134 3201 4268
42x38
11.08
10.67
NC
15
25
Airflow, cfm
2140 3210 4280
40x40
11.11
10.70
NC
15
25
Airflow, cfm
2314 3471 4628
48x36
12.00
11.57
NC
16
25
Airflow, cfm
2364 3546 4728
42x42
12.25
11.82
NC
16
25
Airflow, cfm
2598 3897 5196
44x44
13.44
12.99
NC
16
25
Airflow, cfm
2708 4062 5416
48x42
14.00
13.54
NC
16
26
Airflow, cfm
2844 4266 5688
46x46
14.69
14.22
NC
16
26
Airflow, cfm
2970 4455 5940
48x46
15.33
14.85
NC
17
26
Airflow, cfm
3100 4650 6200
48x48
16.00
15.50
NC
17
26

NC 30

www.titus-hvac.com | www.titus-energysolutions.com

33R RETURN -INCH SPACING 38B DEFLECTION


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

I25

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

I26

30R RETURN 3/8-INCH SPACING 0B DEFLECTION


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC 20
Nominal Nominal Core
Core Velocity
200
300
400
Duct
Duct
Area
Velocity Pressure
0.002 0.006 0.010
Size
Area
sq. ft Neg. Static Pressure 0.006 0.013 0.022
( in. )
sq. ft
6x6
0.25
0.19
Airflow, cfm
38
57
76
NC
8x6
0.33
0.26
Airflow, cfm
52
78
104
NC
10x6
0.42
0.34
Airflow, cfm
68
102
136
NC
8x8
0.44
0.37
Airflow, cfm
74
111
148
NC
12x6
0.50
0.41
Airflow, cfm
82
123
164
NC
14x6
0.58
0.48
Airflow, cfm
96
144
192
NC
11
16x6
Airflow, cfm
114
171
228
12x8
0.67
0.57
NC
12
Airflow, cfm
118
177
236
10x10
0.69
0.59
NC
12
Airflow, cfm
126
189
252
18x6
0.75
0.63
NC
12
20x6
Airflow, cfm
144
216
288
12x10
0.83
0.72
NC
13
Airflow, cfm
154
231
308
22x6
0.92
0.77
NC
13
24x6
Airflow, cfm
176
264
352
12x12
1.00
0.88
NC
14
30x6
Airflow, cfm
222
333
444
18x10
1.25
1.11
NC
15
Airflow, cfm
244
366
488
14x14
1.36
1.22
NC
15
36x6
Airflow, cfm
270
405
540
18x12
1.50
1.35
NC
15
Airflow, cfm
274
411
548
22x10
1.53
1.37
NC
16
30x8
Airflow, cfm
298
447
596
24x10
1.67
1.49
NC
16
42x6
Airflow, cfm
318
477
636
18x14
1.75
1.59
NC
16
16x16
1.78
1.62
Airflow, cfm
324
486
648
NC
16
24x12
2.00
1.82
Airflow, cfm
364
546
728
18x16
NC
17
18x18
2.25
2.07
Airflow, cfm
414
621
828
NC
11
17
2.33
2.14
Airflow, cfm
428
642
856
24x14
NC
11
18
30x12
2.50
2.29
Airflow, cfm
458
687
916
NC
11
18
24x16
2.67
2.46
Airflow, cfm
492
738
984
NC
12
18
20x20
2.78
2.57
Airflow, cfm
514
771
1028
NC
12
18
36x12
3.00
2.75
Airflow, cfm
550
825
1100
NC
12
19
30x16
3.33
3.11
Airflow, cfm
622
933
1244
24x20
NC
13
19
Airflow, cfm
628
942
1256
22x22
3.36
3.14
NC
13
19
42x12
Airflow, cfm
644
966
1288
19
36x14
3.50
3.22
NC
13
Airflow, cfm
686 1029 1372
24x22
3.67
3.43
NC
13
20
Airflow, cfm
700 1050 1400
30x18
3.75
3.50
NC
13
20

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC 30

NC 40

500
600
800 1000 1200 1400
0.016 0.022 0.040 0.062 0.090 0.122
0.035 0.050 0.090 0.140 0.202 0.275
95
12
130
13
170
15
185
15
205
15
240
16
285
17
295
17
315
17
360
18
385
18
440
19
555
20
610
20
675
21
685
21
745
21
795
21
810
21
910
22
1035
22
1070
23
1145
23
1230
23
1285
23
1375
24
1555
24
1570
24
1610
24
1715
25
1750
25

114
16
156
17
204
19
222
19
246
19
288
20
342
21
354
21
378
21
432
22
462
22
528
23
666
24
732
24
810
25
822
25
894
25
954
25
972
25
1092
26
1242
26
1284
27
1374
27
1476
27
1542
27
1650
28
1866
28
1884
28
1932
28
2058
29
2100
29

152
23
208
24
272
25
296
25
328
26
384
27
456
27
472
27
504
28
576
28
616
29
704
29
888
30
976
31
1080
31
1096
31
1192
31
1272
32
1296
32
1456
32
1656
33
1712
33
1832
33
1968
34
2056
34
2200
34
2488
35
2512
35
2576
35
2744
35
2800
35

190
28
260
29
340
30
370
30
410
31
480
32
570
32
590
32
630
33
720
33
770
34
880
34
1110
35
1220
36
1350
36
1370
36
1490
36
1590
37
1620
37
1820
37
2070
38
2140
38
2290
38
2460
39
2570
39
2750
39
3110
40
3140
40
3220
40
3430
40
3500
40

228
32
312
33
408
34
444
35
492
35
576
36
684
36
708
37
756
37
864
37
924
38
1056
38
1332
39
1464
40
1620
40
1644
40
1788
41
1908
41
1944
41
2184
41
2484
42
2568
42
2748
42
2952
43
3084
43
3300
43
3732
44
3768
44
3864
44
4116
44
4200
44

266
35
364
36
476
38
518
38
574
38
672
39
798
40
826
40
882
40
1008
41
1078
41
1232
42
1554
43
1708
43
1890
44
1918
44
2086
44
2226
44
2268
44
2548
45
2898
45
2996
46
3206
46
3444
46
3598
46
3850
47
4354
47
4396
47
4508
47
4802
48
4900
48

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

Specialized Grilles

PERFORMANCE DATA

NC 20

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC 40

NC 50

500
600
800 1000 1200 1400
0.016 0.022 0.040 0.062 0.090 0.122
0.035 0.050 0.090 0.140 0.202 0.275
1875
25
2110
25
2355
26
2470
26
2580
26
2755
27
2830
27
2970
27
3330
27
3340
27
3390
28
3580
28
3815
28
3840
28
4070
28
4190
28
4315
29
4800
29
4820
29
5050
29
5225
29
5335
29
5350
29
5785
30
5910
30
6495
30
6770
31
7110
31
7425
31
7750
31

2250 3000 3750 4500


29
35
40
45
2532 3376 4220 5064
30
36
41
45
2826 3768 4710 5652
30
36
41
46
2964 3952 4940 5928
30
37
42
46
3096 4128 5160 6192
30
37
42
46
3306 4408 5510 6612
31
37
42
46
3396 4528 5660 6792
31
37
42
46
3564 4752 5940 7128
31
37
42
47
3996 5328 6660 7992
32
38
43
47
4008 5344 6680 8016
32
38
43
47
4068 5424 6780 8136
32
38
43
47
4296 5728 7160 8592
32
38
43
47
4578 6104 7630 9156
32
39
44
48
4608 6144 7680 9216
32
39
44
48
4884 6512 8140 9768
32
39
44
48
5028 6704 8380 10056
33
39
44
48
5178 6904 8630 10356
39
33
44
48
5760 7680 9600 11520
33
40
45
49
5784 7712 9640 11568
33
40
45
49
6060 8080 10100 12120
33
40
45
49
6270 8360 10450 12540
33
40
45
49
6402 8536 10670 12804
34
40
45
49
6420 8560 10700 12840
34
40
45
49
6942 9256 11570 13884
49
34
40
45
7092 9456 11820 14184
34
40
45
50
7794 10392 12990 15588
34
41
46
50
8124 10832 13540 16248
35
41
46
50
8532 11376 14220 17064
35
41
46
50
8910 11880 14850 17820
35
41
46
51
9300 12400 15500 18600
35
42
47
51

5250
48
5908
49
6594
49
6916
49
7224
49
7714
50
7924
50
8316
50
9324
51
9352
51
9492
51
10024
51
10682
51
10752
51
11396
51
11732
52
12082
52
13440
52
13496
52
14140
52
14630
52
14938
53
14980
53
16198
53
16548
53
18186
53
18956
54
19908
54
20790
54
21700
54

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

Nominal Nominal Core


Core Velocity
200 300
400
Duct
Duct
Area
Velocity Pressure
0.002 0.006 0.010
Size
Area
sq. ft Neg. Static Pressure 0.006 0.013 0.022
( in. )
sq. ft
48x12
Airflow, cfm
750 1125 1500
24x24
4.00
3.75
NC
13
20
Airflow, cfm
844 1266 1688
36x18
4.50
4.22
NC
14
20
36x20
Airflow, cfm
942 1413 1884
30x24
5.00
4.71
NC
14
21
Airflow, cfm
988 1482 1976
42x18
5.25
4.94
NC
15
21
Airflow, cfm
1032 1548 2064
28x28
5.44
5.16
NC
15
21
42x20
Airflow, cfm
1102 1653 2204
30x28
5.83
5.51
NC
15
22
48x18
Airflow, cfm
1132 1698 2264
36x24
6.00
5.66
NC
15
22
Airflow, cfm
1188 1782 2376
30x30
6.25
5.94
NC
15
22
42x24
Airflow, cfm
1332 1998 2664
36x28
7.00
6.66
NC
16
22
Airflow, cfm
1336 2004 2672
46x22
7.03
6.68
NC
16
22
Airflow, cfm
1356 2034 2712
32x32
7.11
6.78
NC
16
23
Airflow, cfm
1432 2148 2864
36x30
7.50
7.16
NC
16
23
48x24
Airflow, cfm
1526 2289 3052
36x32
8.00
7.63
NC
17
23
Airflow, cfm
1536 2304 3072
34x34
8.03
7.68
NC
17
23
Airflow, cfm
1628 2442 3256
36x34
8.50
8.14
NC
17
23
Airflow, cfm
1676 2514 3352
42x30
8.75
8.38
NC
17
23
Airflow, cfm
1726 2589 3452
36x36
9.00
8.63
NC
17
24
42x34
Airflow, cfm
1920 2880 3840
48x30
10.00
9.60
NC
18
24
Airflow, cfm
1928 2892 3856
38x38
10.03
9.64
NC
18
24
Airflow, cfm
2020 3030 4040
42x36
10.50
10.10
NC
18
24
Airflow, cfm
2090 3135 4180
46x34
10.86
10.45
NC
18
24
Airflow, cfm
2134 3201 4268
42x38
11.08
10.67
NC
18
24
Airflow, cfm
2140 3210 4280
40x40
11.11
10.70
NC
18
24
Airflow, cfm
2314 3471 4628
48x36
12.00
11.57
NC
18
25
Airflow, cfm
2364 3546 4728
42x42
12.25
11.82
NC
18
25
Airflow, cfm
2598 3897 5196
44x44
13.44
12.99
NC
19
25
Airflow, cfm
2708 4062 5416
48x42
14.00
13.54
NC
19
26
Airflow, cfm
2844 4266 5688
46x46
14.69
14.22
NC
19
26
Airflow, cfm
2970 4455 5940
19
48x46
15.33
14.85
NC
26
Airflow, cfm
3100 4650 6200
48x48
16.00
15.50
NC
11
20
26

NC 30

www.titus-hvac.com | www.titus-energysolutions.com

30R RETURN 3/8-INCH SPACING 0B DEFLECTION


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

I27

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

(-inch bar spacing and 0deflection) for the sizes and


mounting types as shown on the plans and outlet schedule.
The fixed deflection bars shall be available parallel to the
long or short dimension of the grille. Construction shall
be of steel with a 1-inch border width on all sides and
a minimum border gauge thickness of 16; bars shall be
14-gauge steel. Bars shall be reinforced by perpendicular,
steel support bars spaced on 6-inch maximum centers.

HEAVY DUTY BAR RETURN GRILLES


GRILLES - STEEL
Available Return Grille Models:
33R/30R
Available Filter Return Grille Models:
33RF/30RF

Corners shall be welded with full penetration resistance


welds with a reinforcing patch for extra strength. Screw
holes shall be countersunk for a neat appearance. Grille
shall be provided with a filter frame for a standard 1-inch
filter to fit the specified duct size.

33R 1/2-INCH SPACING, 38 DEFLECTION


30R 3/8-INCH SPACING, 0 DEFLECTION

Steel return bar grilles shall be Titus Model 33R (-inch bar
spacing and 38 deflection) or 30R (3/8-inch bar spacing
and 0 deflection) for the sizes and mounting types as
shown on the plans and outlet schedule. The fixed deflection
bars shall be available parallel to the long or short dimension
of the grille. Construction shall be of steel with a 1-inch
border width on all sides and a minimum border gauge
thickness of 16; bars shall be 14-gauge steel. Bars shall be
reinforced by perpendicular, steel support bars spaced on
6-inch maximum centers.

FINISH AND PERFORMANCE SPECIFICATIONS

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315 F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.

Corners shall be welded with full penetration resistance


welds with a reinforcing patch for extra strength. Screw
holes shall be countersunk for a neat appearance.

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel. Damper must be operable from the
face of the grille.

33RF -INCH SPACING, 38 DEFLECTION


30RF 3/8-INCH SPACING, 0 DEFLECTION

Steel return filter bar grilles shall be Titus Model 33RF


(-inch bar spacing and 38 deflection) or Model 30RF

MODEL NUMBER SPECIFICATION


Model
33R
30R

Width
38 Deflection

Border Type

0 Deflection

Surface Mount

XXX

Filter Frame

SPECIFICATIONS

(optional)

I28

Parallel
to Long
Dimension

Parallel to Short
Dimension

Blade Orientation

X
Height

Optional Damper
Stainless Steel

26
White
(std.)

Finish

(note)

AG-35
XX-XX

XXX

Aluminum
Plaster Frame

PFAP

Optional

Specialized Grilles

Heavy Duty Bar Return Grilles (continued)

GRILLES - ALUMINUM

Products Include:
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional Aluminum OpposedBlade Damper.
MRI Compatible

63FL
-inch blade spacing.
30 fixed deflection.
Great for areas with high humidity.
Heavy duty design
stands up to abuse.
Blades parallel to the
long dimension.
63FS
Same as 63FL with blades
parallel to the short dimension.

60FL

63FL

Available 30B Deflection Models:


63FL
63FS

Available 0B Deflection Models:
60FL
60FS

60FL
-inch blade spacing.
0 fixed deflection.
Great for areas with high humidity.
Heavy duty design
stands up to abuse.
Blades parallel to the
long dimension.
60FS
Same as 60FL with blades
parallel to the short dimension.

30B Deflection Model 63FL

www.titus-hvac.com | www.titus-energysolutions.com

63FL, 60FL

D plus 1"
D minus "
1"

"

5/16"

19/32"

Optional
Opposed
Blade
Damper

225/32"

Nominal Duct Size D"

Available sizes (D x D) Border Type 1 are 6 x 4 inches through 48 x 48 inches in 1-inch


increments. Odd and fractional sizes are available at additional cost.
0B Deflection Model 60FL
D plus 1"
D minus "
1"

"

5/16"

225/32"

63F, 60F

19/32"

Optional
Opposed
Blade
Damper
Nominal Duct Size D"

Available sizes (D x D) Border Type 1 are 6 x 4 inches through 48 x 48 inches in 1-inch


increments. Odd and fractional sizes are available at additional cost.
All dimensions are in inches.

I29

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

I30

63F RETURN -INCH SPACING 30B DEFLECTION


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
Nominal Nominal Core
Core Velocity, FPM
200 300
Duct
Duct
Area Velocity Pressure, IN WG 0.002 0.006
Size
Area
sq. ft Negative Static Pressure, 0.009 0.020
(IN)
sq. ft
IN WG
6x6
0.25
0.12
Airflow, cfm
24
36
NC
8x6
0.33
0.17
Airflow, cfm
34
51
NC
10x6
0.42
0.22
Airflow, cfm
44
66
NC
8x8
0.44
0.27
Airflow, cfm
53
80
NC
12x6
0.50
0.27
Airflow, cfm
53
80
NC
14x6
0.58
0.32
Airflow, cfm
63
95
NC
18x6
0.75
0.41
Airflow, cfm
83
124
NC
12x8
0.67
0.42
Airflow, cfm
84
126
NC
10x10
0.69
0.47
Airflow, cfm
94
141
NC
22x6
0.92
0.51
Airflow, cfm
102
153
NC
12x10
0.83
0.57
Airflow, cfm
115
172
NC
12x12
1.00
0.73
Airflow, cfm
145
218
NC
18x10
1.25
0.89
Airflow, cfm
177
266
NC
14x14
1.36
1.04
Airflow, cfm
208
311
NC
22x10
1.53
1.09
Airflow, cfm
219
328
NC
18x12
1.50
1.12
Airflow, cfm
224
336
NC
24x10
1.67
1.20
Airflow, cfm
240
359
NC
18x14
1.75
1.36
Airflow, cfm
272
407
NC
16x16
1.78
1.50
Airflow, cfm
300
450
NC
24x12
2.00
1.52
Airflow, cfm
303
455
NC
18x18
2.25
1.83
Airflow, cfm
366
549
NC
24x14
2.33
1.84
Airflow, cfm
367
551
NC
30x12
2.50
1.91
Airflow, cfm
383
574
NC
24x16
2.67
2.16
Airflow, cfm
431
647
NC
20x20
2.78
2.31
Airflow, cfm
462
693
NC
36x12
3.00
2.31
Airflow, cfm
462
693
NC
42x12
3.50
2.70
Airflow, cfm
541
811
NC
24x20
3.33
2.80
Airflow, cfm
559
839
NC
22x22
3.36
2.84
Airflow, cfm
569
853
NC
24x22
3.67
3.11
Airflow, cfm
623
934
NC
-

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

400 500 600 700 800 900 1000 1100 1200 1300 1400 1500
0.010 0.016 0.022 0.031 0.040 0.050 0.062 0.075 0.090 0.105 0.122 0.140
0.035 0.055 0.079 0.108 0.140 0.178 0.219 0.265 0.316 0.371 0.430 0.494
49
68
88
107
107
126
165
168
188
204
229
290
354
10
415
11
438
11
449
11
479
11
543
12
600
13
607
13
732
14
735
14
765
14
863
15
924
15
924
15
1082
16
1118
16
1138
16
1246
16

61
85
109
10
134
11
134
11
158
12
207
13
210
13
234
14
255
14
286
15
363
16
443
17
519
18
547
18
561
18
599
19
679
19
750
20
759
20
915
21
918
21
957
21
1078
22
1155
22
1155
22
1352
23
1398
23
1422
23
1557
24

73
13
102
14
131
16
160
17
160
17
190
18
248
19
252
19
281
20
306
20
344
21
435
22
531
23
623
24
656
24
673
24
719
25
815
25
900
26
910
26
1098
27
1102
27
1148
27
1294
28
1385
28
1385
28
1623
29
1677
29
1706
29
1869
30

85
18
119
19
153
21
187
22
187
22
221
23
289
24
294
24
328
25
357
25
401
26
508
27
620
28
727
29
766
29
785
29
839
29
950
30
1050
31
1062
31
1281
32
1286
32
1339
32
1509
33
1616
33
1616
33
1893
34
1957
34
1991
34
2180
34

97
22
136
24
175
25
214
26
214
26
253
27
331
28
336
28
375
29
408
29
458
30
581
31
708
32
831
33
875
33
897
33
958
34
1086
34
1200
35
1214
35
1464
36
1469
36
1531
36
1725
37
1847
37
1847
37
2164
38
2236
38
2275
38
2492
39

109
26
153
27
197
29
241
30
241
30
284
31
372
32
378
32
422
33
459
33
516
34
653
35
797
36
934
37
984
37
1009
37
1078
38
1222
38
1350
39
1366
39
1647
40
1653
40
1722
40
1941
41
2078
41
2078
41
2434
42
2516
42
2559
42
2803
43

122
29
170
31
219
32
267
33
267
33
316
34
413
35
420
35
469
36
510
36
573
37
726
38
885
39
1038
40
1094
40
1122
41
1198
41
1358
42
1500
42
1517
42
1830
43
1837
43
1913
43
2156
44
2309
44
2309
44
2705
45
2795
45
2844
45
3115
46

134
32
187
34
241
35
294
36
294
36
348
37
455
38
462
39
516
39
561
40
630
40
798
41
974
42
1142
43
1203
44
1234
44
1318
44
1493
45
1650
45
1669
45
2013
46
2020
46
2105
46
2372
47
2540
47
2540
47
2975
48
3075
48
3128
49
3426
49

146
35
204
37
263
38
321
39
321
39
379
40
496
41
504
41
563
42
613
42
688
43
871
44
1063
45
1246
46
1313
46
1346
46
1438
47
1629
47
1800
48
1821
48
2196
49
2204
49
2296
49
2588
50
2771
50
2771
50
3246
51
3354
51
3413
51
3738
52

158
37
221
39
284
41
348
42
348
42
411
42
537
44
546
44
609
44
664
45
745
46
943
47
1151
48
1350
49
1422
49
1458
49
1557
49
1765
50
1950
51
1973
51
2379
52
2388
52
2487
52
2803
52
3002
53
3002
53
3516
54
3634
54
3697
54
4049
54

170
40
238
42
306
43
374
44
374
44
442
45
578
46
588
46
656
47
715
47
802
48
1016
49
1240
50
1453
51
1531
51
1570
51
1677
52
1901
52
2100
53
2124
53
2562
54
2572
54
2678
54
3019
55
3233
55
3233
55
3787
56
3913
56
3981
56
4360
57

182
42
255
44
328
45
401
46
401
46
474
47
620
48
630
49
703
49
766
50
859
50
1089
51
1328
52
1557
53
1641
53
1682
54
1797
54
2036
55
2250
55
2276
55
2745
56
2755
56
2870
56
3234
57
3464
57
3464
57
4057
58
4193
58
4266
58
4672
59

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

Specialized Grilles

PERFORMANCE DATA

200 250 300 350 400 450 500 550 600 650 700 750 800 850
0.002 0.004 0.006 0.008 0.010 0.013 0.016 0.019 0.022 0.026 0.031 0.035 0.040 0.045
0.009 0.014 0.020 0.027 0.035 0.044 0.055 0.066 0.079 0.093 0.108 0.123 0.140 0.159
624
687
753
851
883
956
997
1012
1108
1219
1224
1270
1337
1403
1531
1566
1628
1795
1824
1908
1969
2022
2031
2187
2249
2478
2578
2719
2840
2970
-

780
859
942
1063
1103
1195
1246
1265
1385
1523
1530
1588
1671
1754
1914
1957
2036
2244
2280
2385
2461
2527
2539
2734
2812
3098
3223
3398
3549
3713
10

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

936
1030
1130
1276
1324
1434
1495
10
1518
10
1661
10
1828
11
1836
11
1905
11
2005
11
2105
11
2297
12
2349
12
2443
12
2693
13
2736
13
2861
13
2953
13
3032
13
3047
13
3280
14
3374
14
3718
14
3868
15
4078
15
4259
15
4455
15

1093
12
1202
13
1319
13
1489
14
1545
14
1673
14
1744
15
1771
15
1938
15
2133
16
2143
16
2223
16
2339
16
2456
16
2680
17
2740
17
2850
17
3141
18
3193
18
3338
18
3445
18
3538
18
3555
18
3827
19
3936
19
4337
19
4512
20
4758
20
4969
20
5198
20

1249
16
1374
17
1507
17
1701
18
1765
18
1913
19
1993
19
2024
19
2215
19
2438
20
2449
20
2540
20
2674
20
2807
21
3063
21
3132
21
3257
21
3590
22
3649
22
3815
22
3938
22
4043
23
4063
23
4374
23
4499
23
4957
24
5157
24
5438
24
5679
24
5940
25

1405
20
1545
21
1695
21
1914
22
1986
22
2152
22
2242
23
2277
23
2492
23
2742
24
2755
24
2858
24
3008
24
3158
24
3445
25
3523
25
3664
25
4039
26
4105
26
4292
26
4430
26
4548
26
4570
26
4920
27
5061
27
5577
27
5802
28
6117
28
6389
28
6683
28

1561
24
1717
24
1884
25
2127
25
2207
25
2391
26
2491
26
2530
26
2769
27
3047
27
3061
27
3175
27
3342
28
3509
28
3828
28
3915
28
4071
29
4488
29
4561
29
4769
29
4922
30
5054
30
5078
30
5467
30
5623
30
6196
31
6446
31
6797
31
7099
32
7425
32

1717
27
1889
27
2072
28
2339
28
2427
29
2630
29
2740
29
2782
29
3046
30
3352
30
3367
30
3493
30
3676
31
3860
31
4211
31
4306
32
4478
32
4937
32
5017
32
5246
33
5414
33
5559
33
5586
33
6014
33
6186
33
6816
34
7091
34
7477
34
7809
35
8168
35

1873
30
2060
30
2260
30
2552
31
2648
31
2869
32
2990
32
3035
32
3323
33
3656
33
3673
33
3810
33
4010
33
4210
34
4594
34
4698
34
4885
35
5385
35
5473
35
5723
35
5906
36
6065
36
6094
36
6560
36
6748
36
7435
37
7735
37
8156
37
8519
37
8910
38

2029 2185
32
34
2232 2404
33
35
2449 2637
33
35
2765 2977
34
36
2869 3089
34
36
3108 3347
34
37
3239 3488
35
37
3288 3541
35
37
3600 3877
35
37
3961 4266
36
38
3979 4285
36
38
4128 4445
36
38
4345 4679
36
38
4561 4912
36
39
4977 5359
37
39
5089 5481
37
39
5293 5700
37
39
5834 6283
38
40
5929 6385
38
40
6200 6677
38
40
6398 6891
38
40
6570 7075
38
41
6602 7109
38
41
7107 7654
39
41
7310 7873
39
41
8055 8675
39
42
8380 9025
39
42
8836 9516
40
42
9229 9939
40
42
9653 10395
40
43

2341
37
2576
37
2826
38
3190
38
3310
38
3586
39
3737
39
3794
39
4154
40
4570
40
4591
40
4763
40
5013
41
5263
41
5742
41
5872
41
6107
42
6732
42
6841
42
7154
43
7383
43
7581
43
7617
43
8201
43
8435
43
9294
44
9669
44
10195
44
10648
45
11138
45

2497
39
2747
39
3014
40
3403
40
3531
41
3825
41
3986
41
4047
41
4431
42
4875
42
4897
42
5081
42
5347
43
5614
43
6125
43
6264
44
6514
44
7181
44
7297
44
7631
45
7875
45
8086
45
8125
45
8747
45
8997
45
9914
46
10314
46
10875
46
11358
47
11881
47

2653
41
2919
41
3202
42
3615
42
3751
43
4064
43
4235
43
4300
43
4707
44
5180
44
5203
44
5398
44
5681
45
5965
45
6508
45
6655
46
6921
46
7629
46
7753
46
8107
47
8367
47
8591
47
8633
47
9294
47
9560
47
10534
48
10959
48
11555
48
12068
49
12623
49

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

Nominal Nominal Core


Core Velocity, FPM
Duct
Duct
Area Velocity Pressure, IN WG
Size
Area sq. ft Negative Static Pressure,
(IN)
sq. ft
IN WG
30x18
3.75
3.12
Airflow, cfm
NC
24x24
4.00
3.43
Airflow, cfm
NC
36x18
4.50
3.77
Airflow, cfm
NC
36x20
5.00
4.25
Airflow, cfm
NC
42x18
5.25
4.41
Airflow, cfm
NC
28x28
5.44
4.78
Airflow, cfm
NC
42x20
5.83
4.98
Airflow, cfm
NC
48x18
6.00
5.06
Airflow, cfm
NC
30x30
6.25
5.54
Airflow, cfm
NC
46x22
7.03
6.09
Airflow, cfm
NC
42x24
7.00
6.12
Airflow, cfm
NC
32x32
7.11
6.35
Airflow, cfm
NC
36x30
7.50
6.68
Airflow, cfm
NC
48x24
8.00
7.02
Airflow, cfm
NC
36x34
8.50
7.66
Airflow, cfm
NC
42x30
8.75
7.83
Airflow, cfm
NC
36x36
9.00
8.14
Airflow, cfm
NC
48x30
10.00
8.98
Airflow, cfm
NC
38x38
10.03
9.12
Airflow, cfm
NC
42x36
10.50
9.54
Airflow, cfm
NC
46x34
10.86
9.84
Airflow, cfm
NC
42x38
11.08 10.11
Airflow, cfm
NC
40x40
11.11 10.16
Airflow, cfm
NC
48x36
12.00 10.93
Airflow, cfm
NC
42x42
12.25 11.25
Airflow, cfm
NC
44x44
13.44 12.39
Airflow, cfm
NC
48x42
14.00 12.89
Airflow, cfm
NC
46x46
14.69 13.59
Airflow, cfm
NC
48x46
15.33 14.20
Airflow, cfm
NC
48x48
16.00 14.85
Airflow, cfm
NC

www.titus-hvac.com | www.titus-energysolutions.com

63F RETURN -INCH SPACING 30B DEFLECTION (CONTINUED)


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

I31

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

I32

60F RETURN -INCH SPACING 0B DEFLECTION


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
Nominal Nominal Core
Core Velocity, FPM
Duct
Duct
Area Velocity Pressure, IN WG
Size
Area
sq. ft Negative Static Pressure,
(IN)
sq. ft
IN WG
6x6
0.25
0.12
Airflow, cfm
NC
8x6
0.33
0.17
Airflow, cfm
NC
10x6
0.42
0.22
Airflow, cfm
NC
8x8
0.44
0.27
Airflow, cfm
NC
12x6
0.50
0.27
Airflow, cfm
NC
14x6
0.58
0.32
Airflow, cfm
NC
18x6
0.75
0.41
Airflow, cfm
NC
12x8
0.67
0.42
Airflow, cfm
NC
10x10
0.69
0.47
Airflow, cfm
NC
22x6
0.92
0.51
Airflow, cfm
NC
12x10
0.83
0.57
Airflow, cfm
NC
12x12
1.00
0.73
Airflow, cfm
NC
18x10
1.25
0.89
Airflow, cfm
NC
14x14
1.36
1.04
Airflow, cfm
NC
22x10
1.53
1.09
Airflow, cfm
NC
18x12
1.50
1.12
Airflow, cfm
NC
24x10
1.67
1.20
Airflow, cfm
NC
18x14
1.75
1.36
Airflow, cfm
NC
16x16
1.78
1.50
Airflow, cfm
NC
24x12
2.00
1.52
Airflow, cfm
NC
18x18
2.25
1.83
Airflow, cfm
NC
24x14
2.33
1.84
Airflow, cfm
NC
30x12
2.50
1.91
Airflow, cfm
NC
24x16
2.67
2.16
Airflow, cfm
NC
20x20
2.78
2.31
Airflow, cfm
NC
36x12
3.00
2.31
Airflow, cfm
NC
42x12
3.50
2.70
Airflow, cfm
NC
24x20
3.33
2.80
Airflow, cfm
NC
22x22
3.36
2.84
Airflow, cfm
NC
24x22
3.67
3.11
Airflow, cfm
NC

200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500
0.002 0.006 0.010 0.016 0.022 0.031 0.040 0.050 0.062 0.075 0.090 0.105 0.122 0.140
0.005 0.012 0.020 0.032 0.046 0.063 0.082 0.104 0.128 0.155 0.184 0.216 0.251 0.288
24
34
44
53
53
63
83
84
94
102
115
145
177
208
219
224
240
272
300
303
366
367
383
431
462
462
541
559
569
623
-

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

36
51
66
80
80
95
124
126
141
153
172
218
266
311
328
336
359
407
450
455
549
551
574
647
693
693
811
839
853
934
-

49
68
88
107
107
126
165
168
188
204
229
290
354
415
438
449
479
543
600
607
732
735
765
863
924
924
1082
1118
1138
10
1246
10

61
85
109
134
134
158
207
10
210
10
234
11
255
11
286
11
363
12
443
12
519
13
547
13
561
13
599
13
679
14
750
14
759
14
915
15
918
15
957
15
1078
15
1155
15
1155
15
1352
16
1398
16
1422
16
1557
16

73
12
102
13
131
14
160
14
160
14
190
15
248
15
252
15
281
16
306
16
344
16
435
17
531
18
623
18
656
18
673
18
719
19
815
19
900
19
910
19
1098
20
1102
20
1148
20
1294
20
1385
21
1385
21
1623
21
1677
21
1706
21
1869
22

85
16
119
17
153
18
187
19
187
19
221
19
289
20
294
20
328
20
357
21
401
21
508
22
620
22
727
23
766
23
785
23
839
23
950
24
1050
24
1062
24
1281
24
1286
24
1339
25
1509
25
1616
25
1616
25
1893
26
1957
26
1991
26
2180
26

97
20
136
21
175
22
214
22
214
22
253
23
331
24
336
24
375
24
408
24
458
25
581
26
708
26
831
27
875
27
897
27
958
27
1086
27
1200
28
1214
28
1464
28
1469
28
1531
28
1725
29
1847
29
1847
29
2164
30
2236
30
2275
30
2492
30

109
24
153
25
197
25
241
26
241
26
284
26
372
27
378
27
422
28
459
28
516
28
653
29
797
30
934
30
984
30
1009
30
1078
30
1222
31
1350
31
1366
31
1647
32
1653
32
1722
32
1941
32
2078
32
2078
32
2434
33
2516
33
2559
33
2803
33

122
27
170
28
219
28
267
29
267
29
316
29
413
30
420
30
469
31
510
31
573
31
726
32
885
33
1038
33
1094
33
1122
33
1198
34
1358
34
1500
34
1517
34
1830
35
1837
35
1913
35
2156
35
2309
36
2309
36
2705
36
2795
36
2844
36
3115
36

134
29
187
30
241
31
294
32
294
32
348
32
455
33
462
33
516
33
561
34
630
34
798
35
974
35
1142
36
1203
36
1234
36
1318
36
1493
37
1650
37
1669
37
2013
38
2020
38
2105
38
2372
38
2540
38
2540
38
2975
39
3075
39
3128
39
3426
39

146
32
204
33
263
34
321
34
321
34
379
35
496
36
504
36
563
36
613
36
688
37
871
37
1063
38
1246
38
1313
39
1346
39
1438
39
1629
39
1800
40
1821
40
2196
40
2204
40
2296
40
2588
41
2771
41
2771
41
3246
41
3354
41
3413
41
3738
42

158
34
221
35
284
36
348
37
348
37
411
37
537
38
546
38
609
38
664
39
745
39
943
40
1151
40
1350
41
1422
41
1458
41
1557
41
1765
42
1950
42
1973
42
2379
42
2388
42
2487
43
2803
43
3002
43
3002
43
3516
44
3634
44
3697
44
4049
44

170
36
238
37
306
38
374
39
374
39
442
39
578
40
588
40
656
40
715
41
802
41
1016
42
1240
42
1453
43
1531
43
1570
43
1677
43
1901
44
2100
44
2124
44
2562
45
2572
45
2678
45
3019
45
3233
45
3233
45
3787
46
3913
46
3981
46
4360
46

182
38
255
39
328
40
401
41
401
41
474
41
620
42
630
42
703
42
766
43
859
43
1089
44
1328
44
1557
45
1641
45
1682
45
1797
45
2036
46
2250
46
2276
46
2745
47
2755
47
2870
47
3234
47
3464
47
3464
47
4057
48
4193
48
4266
48
4672
48

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

Specialized Grilles

PERFORMANCE DATA

Nominal Nominal Core


Duct

Duct

Area

Area

sq. ft

sq. ft
3.75

3.12

24x24

4.00

3.43

36x18

4.50

3.77

36x20

5.00

4.25

42x18

5.25

4.41

28x28

5.44

4.78

42x20

5.83

4.98

48x18

6.00

5.06

30x30

6.25

5.54

46x22

7.03

6.09

42x24

7.00

6.12

32x32

7.11

6.35

36x30

7.50

6.68

48x24

8.00

7.02

36x34

8.50

7.66

42x30

8.75

7.83

36x36

9.00

8.14

48x30

10.00

8.98

38x38

10.03

9.12

42x36

10.50

9.54

46x34

10.86

9.84

42x38

11.08

10.11

40x40

11.11

10.16

48x36

12.00

10.93

42x42

12.25

11.25

44x44

13.44

12.39

48x42

14.00

12.89

46x46

14.69

13.59

48x46

15.33

14.20

48x48

16.00

14.85

300

350

400

450

500

550

600

650

700

800

900

1000 1100 1200

0.006 0.008 0.010 0.013 0.016 0.019 0.022 0.026 0.031 0.040 0.050 0.062 0.075 0.090
0.012 0.016 0.020 0.026 0.032 0.039 0.046 0.054 0.063 0.082 0.104 0.128 0.155 0.184
936
1030
1130
1276
1324
1434
1495
1518
1661
1828
1836
1905
2005
2105
2297
2349
2443
2693
2736
2861
2953
3032
3047
3280
3374
3718
3868
4078
4259
4455
-

1093
1202
1319
1489
1545
1673
1744
1771
1938
2133
2143
2223
2339
2456
2680
2740
2850
3141
3193
3338
3445
3538
3555
3827
10
3936
10
4337
10
4512
10
4758
10
4969
11
5198
11

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

1249
10
1374
10
1507
10
1701
11
1765
11
1913
11
1993
11
2024
11
2215
12
2438
12
2449
12
2540
12
2674
12
2807
12
3063
13
3132
13
3257
13
3590
13
3649
13
3815
13
3938
13
4043
13
4063
13
4374
14
4499
14
4957
14
5157
14
5438
14
5679
14
5940
15

1405
13
1545
14
1695
14
1914
14
1986
14
2152
15
2242
15
2277
15
2492
15
2742
15
2755
15
2858
15
3008
16
3158
16
3445
16
3523
16
3664
16
4039
16
4105
16
4292
17
4430
17
4548
17
4570
17
4920
17
5061
17
5577
17
5802
18
6117
18
6389
18
6683
18

1561
16
1717
17
1884
17
2127
17
2207
17
2391
18
2491
18
2530
18
2769
18
3047
18
3061
18
3175
18
3342
19
3509
19
3828
19
3915
19
4071
19
4488
20
4561
20
4769
20
4922
20
5054
20
5078
20
5467
20
5623
20
6196
20
6446
21
6797
21
7099
21
7425
21

1717
19
1889
19
2072
20
2339
20
2427
20
2630
20
2740
20
2782
21
3046
21
3352
21
3367
21
3493
21
3676
21
3860
22
4211
22
4306
22
4478
22
4937
22
5017
22
5246
22
5414
23
5559
23
5586
23
6014
23
6186
23
6816
23
7091
23
7477
24
7809
24
8168
24

1873
22
2060
22
2260
22
2552
23
2648
23
2869
23
2990
23
3035
23
3323
23
3656
24
3673
24
3810
24
4010
24
4210
24
4594
24
4698
24
4885
25
5385
25
5473
25
5723
25
5906
25
6065
25
6094
25
6560
25
6748
25
7435
26
7735
26
8156
26
8519
26
8910
26

2029 2185
24
26
2232 2404
24
26
2449 2637
24
27
2765 2977
25
27
2869 3089
25
27
3108 3347
25
27
3239 3488
25
28
3288 3541
25
28
3600 3877
26
28
3961 4266
26
28
3979 4285
26
28
4128 4445
26
28
4345 4679
26
28
4561 4912
26
29
4977 5359
27
29
5089 5481
27
29
5293 5700
27
29
5834 6283
27
29
5929 6385
27
29
6200 6677
27
29
6398 6891
27
30
6570 7075
27
30
6602 7109
28
30
7107 7654
28
30
7310 7873
28
30
8055 8675
28
30
8380 9025
28
30
8836 9516
28
31
9229 9939
29
31
9653 10395
29
31

2497
30
2747
30
3014
31
3403
31
3531
31
3825
31
3986
31
4047
31
4431
32
4875
32
4897
32
5081
32
5347
32
5614
32
6125
33
6264
33
6514
33
7181
33
7297
33
7631
33
7875
33
8086
34
8125
34
8747
34
8997
34
9914
34
10314
34
10875
34
11358
35
11881
35

2809
33
3091
34
3391
34
3828
34
3972
34
4303
35
4484
35
4553
35
4984
35
5484
35
5509
35
5716
36
6016
36
6316
36
6891
36
7047
36
7328
36
8078
37
8209
37
8584
37
8859
37
9097
37
9141
37
9841
37
10122
37
11153
38
11603
38
12234
38
12778
38
13366
38

3122
36
3434
37
3767
37
4253
37
4413
38
4781
38
4983
38
5059
38
5538
38
6094
38
6122
39
6351
39
6684
39
7017
39
7656
39
7830
39
8142
39
8976
40
9122
40
9538
40
9844
40
10108
40
10156
40
10934
40
11247
40
12392
41
12892
41
13594
41
14198
41
14851
41

3434
39
3777
40
4144
40
4679
40
4855
40
5259
41
5481
41
5565
41
6092
41
6703
41
6734
41
6986
41
7352
42
7719
42
8422
42
8613
42
8957
42
9873
42
10034
42
10492
43
10828
43
11118
43
11172
43
12027
43
12371
43
13632
43
14182
44
14953
44
15618
44
16336
44

3746
42
4121
42
4521
42
5104
43
5296
43
5738
43
5979
43
6071
43
6646
44
7313
44
7346
44
7621
44
8021
44
8421
44
9188
44
9396
45
9771
45
10771
45
10946
45
11446
45
11813
45
12129
45
12188
45
13121
46
13496
46
14871
46
15471
46
16313
46
17038
46
17821
47

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

PERFORMANCE DATA

Size
(IN)
30x18

Core Velocity, FPM


Velocity Pressure, IN
WG
Negative Static
Pressure,
IN WG
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC
Airflow, cfm
NC

www.titus-hvac.com | www.titus-energysolutions.com

60F RETURN -INCH SPACING 0B DEFLECTION (CONTINUED)


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

I33

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

GRILLES - ALUMINUM

63F -INCH SPACING, 30 DEFLECTION


60F -INCH SPACING, 0 DEFLECTION

Aluminum return bar grilles shall be Titus Model 63F


(-inch bar spacing and 30 deflection) or 60F (-inch
bar spacing and 0B deflection) for the sizes and mounting
types as shown on the plans and outlet schedule. The fixed
deflection bars shall be available parallel to the long or short
dimension of the grille. Construction shall be aluminum with
a 1-inch border with on all sides. Bars shall be reinforced
by perpendicular support bars. Screw holes shall be
countersunk for improved appearance.

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315 F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Model
63F
60F

Width
30 Deflection

Border Type

0 Deflection

Surface Mount

Parallel to Long
Dimension

Parallel to Short
Dimension

X
Height

1
White (std.)
Clear Anodized

Blade Orientation

SPECIFICATIONS

FINISH AND PERFORMANCE SPECIFICATIONS

Available Return Grille Models:


63F/60F

XXX

I34

Optional opposed-blade volume damper shall be constructed


of heavy gauge aluminum or steel. Damper must be
operable from the face of the grille.

HEAVY DUTY BAR RETURN GRILLES

Optional Damper
AG-50

Aluminum

XX
26
34
Finish

XX-XX

XXX

Aluminum
Plaster Frame

PFA

Optional

Specialized Grilles

Spiral Duct Mounted Grilles

Available Single Deflection Models:


S301FL
S301FS

Available Double Deflection Models:
S300FL
S300FS
Products Include:
Material: Aluminum extruded
borders and blades.
Standard Finish - #26 White
or #34 Clear Anodize.
Countersunk screw holes
and curved end caps.
Foam gasketing standard for tight seal.
Optional ASD-Air scoop
damper/extractor.

S301FL (Single Deflection)


-inch blade spacing.
Individually adjustable blades.
Radius endcaps match duct to
avoid installation cost of duct taps.
Blades parallel to the
long dimension.

S300FL (Double Deflection)


-inch blade spacing.
Individually adjustable blades.
Radius endcaps match duct to
avoid installation cost of duct taps.
Blades parallel to the
long dimension.

S301FS
Same as S301FL with blades
parallel to the short dimension.

S300FS
Same as S300FL with blades
parallel to the short dimension.
Width plus 1"
Width minus "

S301FL/FS
Direct duct mounted
with radius End Cap

www.titus-hvac.com | www.titus-energysolutions.com

S301(FL, FS), S300 (FL, FS)

S301(FL/FS), S300(FL/FS)

2"
1"

5/16"

"

1"
Height
minus "

Height

Min : Max
Duct Diameter

3
4
6
8
10
12

6 : 36
8 : 36
10 : 36
12 : 36
14 : 36
16 : 36

Height
plus 1"
Air Scoop
Adjustment
Screw

Width plus 1"


Width minus "

S300FL/FS
Direct duct mounted
with radius End Cap

2"
1"

Height
minus "

Height
plus 1"
Air Scoop
Adjustment
Screw

Airflow

S301F, S300F

All dimensions are in inches.

"

1"

S300FL/FS Direct duct mounted with radius End Cap


Application Note: For duct velocities
up to 800 fpm, the damper/extractor is
not required. For duct velocities higher
than 800 fpm, the damper/extractor is
recommended.

5/16"

I35

Specialized Grilles

US301
Available Single Deflection Models:
US301FL
US301FS

Available Double Deflection Models:
US300FL
US300FS
Products Include:
Material: Aluminum extruded
borders and blades.
Standard Finish - #26 White
or #34 Clear Anodize.
Countersunk screw holes.
Foam gasketing standard for tight seal.
Optional ASD-Air scoop
damper/extractor.

US301FL (Single Deflection)


-inch blade spacing.
Individually adjustable blades.
Universal endcaps match
multiple duct diameters to avoid
installation cost of duct taps.
Blades parallel to the
long dimension.

US300FL (Double Deflection)


-inch blade spacing.
Individually adjustable blades.
Universal endcaps multiple
duct diameters to avoid
installation cost of duct taps.
Blades parallel to the
long dimension.

US301FS
Same as US301FL with blades
parallel to the short dimension.

US300FS
Same as US300FL with blades
parallel to the short dimension.

US301FL/FS
Direct duct mounted
with universal
End Cap

Width plus 3"


Width minus "

End Cap
Gasket Seal

1"
CROSS SECTION VIEW

Gasket Surrounds
Blade Assembly

1"

"

Height
3
4
6
8
10
12

Min : Max
Duct Diameter
10
10
12
20
24
24

:
:
:
:
:
:

36
36
36
36
36
36

Height
minus "

US300FL/FS
Direct duct mounted
with universal
End Cap

Air Scoop
Adjustment
Screw

Width plus 3"


Width minus "
End Cap
Gasket Seal
1"
CROSS SECTION VIEW

Gasket Surrounds
Blade Assembly

"

US301F, US300F

Height
minus "

I36

Air Scoop
Adjustment
Screw

US300FL/FS Direct duct mounted with universal End Cap


Airflow

Application Note: For duct velocities


up to 800 fpm, the damper/extractor is
not required. For duct velocities higher
than 800 fpm, the damper/extractor is
recommended.
All dimensions are in inches.

1"

US300FS

www.titus-hvac.com | www.titus-energysolutions.com

Spiral Duct-Mounted Grilles (continued)

Specialized Grilles

Spiral Duct-Mounted Grilles (continued)

Products Include:
Material: Aluminum extended
frame and perforated sheet.
Standard Finish - #26 White
or #34 Clear Anodize.
Countersunk screw holes with
curved border (S8F) or universal
duct size border (US8F).
Foam gasketing standard for tight seal.

S8F, US8F

Available 3/16-inch Perforated Hole Model with


Radius End Caps:
S8F

Available 3/16-inch Perforated Hole Model with
Universal End Caps:
US8F
S8F
3/16-inch perforated holes on

-inch staggered centers.
Radius endcaps match duct to
avoid installation cost of duct taps.

US8F
Same as S8F except with universal
border allows grille to match
multiple duct diameters, save
installation cost of duct taps.

Width plus 1"


Width minus "

S8F
Direct duct mounted
with Radius End Cap

2"

S8F
Height

Min : Max
Duct Diameter

3
4
6
8
10
12

6 : 36
8 : 36
10 : 36
12 : 36
14 : 36
16 : 36

US8F
Height

10
10
12
20
24
24

:
:
:
:
:
:

1"

1"
Height
minus "

US8F
Direct duct mounted
with Universal
End Cap

Height plus 1"

Width plus 3"


Width minus "
1"

3/16" Perforations on "


Staggered Centers

CROSS SECTION VIEW

36
36
36
36
36
36

* For Performance Data see 8F

5/16"

1"

Gasket
Surrounds
Blade
Assembly

Height
minus "

All dimensions are in inches.

S8F, US8F

3
4
6
8
10
12

Min : Max
Duct Diameter

www.titus-hvac.com | www.titus-energysolutions.com

S8F, US8F

I37

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

S300F, US300F, S301F AND US301F SUPPLY WITH NO EXTRACTOR


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
Nominal Nominal
Core
Duct
Duct
Area
Size
Area
sq. ft
( in. )
sq. ft

10x3

0.21

0.14

12x3

0.25

0.18

10x4
14x3

0.28

0.21

0.33

0.25

0.38

0.27

0.42

0.3

0.44

0.34

0.50

0.39

0.56

0.43

0.61

0.48

0.67

0.52

16x3
12x4

18x3
14x4
10x6
20x3

16x4
22x3
24x3
12x6
18x4
26x3

PERFORMANCE DATA

14x6
20x4
28x3

I38

22x4
30x3
32x3
24x4
16x6
12x8

Core Velocity,
( fpm )
Velocity Pressure
Total
0
Pressure
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45

300

400

500

600

700

800

1000

0.006
0.016
0.018
0.028
42
3-6-8
2-5-6
1-3-4
54
5-7-9
4-5-7
2-3-4
63
5-7-10
4-6-8
2-3-5
75
5-8-11
4-6-9
2-4-5
81
6-8-12
4-6-9
2-4-5
90
6-9-12
5-7-9
3-4-5
102
6-9-13
5-7-10
3-4-6
117
7-10-14
5-8-11
3-4-6
129
7-10-15
5-8-11
3-5-7
144
7-11-15
6-8-12
3-5-7
156
8-11-16
6-9-12
3-5-7

0.010
0.029
0.033
0.049
56
4-7-10
3-5-7
2-3-4
72
6-8-11
5-6-8
3-3-5
84
7-8-12
5-6-9
3-4-5
100
7-9-13
6-7-10
3-4-6
108
8-9-13
6-7-10
3-4-6
120
8-10-14
6-8-11
4-4-6
136
9-11-15
7-8-12
4-5-7
156
9-11-16
7-9-12
4-5-7
172
10-12-17
8-9-13
4-5-8
192
10-13-18
8-10-14
5-6-8
208
11-13-19
8-10-14
5-6-8

0.016
0.046
0.051
0.077
70
5-8-11
4-6-8
2-3-5
90
7-9-12
5-7-9
3-4-5
105
8-9-13
6-7-10
3-4-6
125
11
8-10-14
6-8-11
4-5-6
135
12
9-11-15
7-8-12
4-5-7
150
12
9-11-16
7-9-12
4-5-7
170
12
10-12-17
8-9-13
4-5-8
195
13
10-13-18
8-10-14
5-6-8
215
13
11-13-19
8-10-15
5-6-8
240
14
12-14-20
9-11-15
5-6-9
260
14
12-15-21
9-11-16
5-7-9

0.022
0.066
0.074
0.111
84
14
6-8-12
5-6-9
3-4-5
108
15
8-9-13
6-7-10
3-4-6
126
16
8-10-14
6-8-11
4-5-7
150
17
9-11-16
7-9-12
4-5-7
162
17
9-12-16
7-9-13
4-5-7
180
17
10-12-17
8-9-13
4-5-8
204
18
11-13-18
8-10-14
5-6-8
234
18
11-14-20
9-11-15
5-6-9
258
19
12-15-21
9-11-16
5-7-9
288
19
13-15-22
10-12-17
6-7-10
312
20
13-16-23
10-12-18
6-7-10

0.031
0.090
0.100
0.152
98
19
7-9-13
5-7-10
3-4-6
126
20
8-10-14
6-8-11
4-5-7
147
21
9-11-16
7-9-12
4-5-7
175
21
10-12-17
8-9-13
4-5-8
189
22
10-13-18
8-10-14
5-6-8
210
22
11-13-19
8-10-14
5-6-8
238
23
11-14-20
9-11-15
5-6-9
273
23
12-15-21
10-12-16
6-7-10
301
24
13-16-22
10-12-17
6-7-10
336
24
14-17-24
11-13-18
6-8-11
364
24
14-17-25
11-13-19
6-8-11

0.040
0.117
0.131
0.198
112
23
8-10-14
6-7-11
4-4-6
144
24
9-11-15
7-8-12
4-5-7
168
25
10-12-17
7-9-13
4-5-8
200
25
11-13-18
8-10-14
5-6-8
216
26
11-13-19
8-10-15
5-6-9
240
26
12-14-20
9-11-15
5-6-9
272
27
12-15-21
9-12-16
6-7-10
312
27
13-16-23
10-12-18
6-7-10
344
27
14-17-24
11-13-18
6-8-11
384
28
15-18-25
11-14-20
7-8-11
416
28
15-19-26
12-14-20
7-8-12

0.062
0.183
0.204
0.309
140
29
9-11-15
7-8-12
4-5-7
180
31
10-12-17
8-9-13
4-5-8
210
31
11-13-19
8-10-14
5-6-8
250
32
12-14-20
9-11-16
5-6-9
270
32
12-15-21
9-12-16
5-7-10
300
33
13-16-22
10-12-17
6-7-10
340
33
14-17-24
11-13-18
6-8-11
390
34
15-18-25
11-14-20
7-8-11
430
34
15-19-27
12-15-21
7-8-12
480
35
16-20-28
13-15-22
7-9-13
520
35
17-21-29
13-16-23
8-9-13

Performance data obtained in actual


application conditions - direct duct mounted
grille, 90 to airflow with no ceiling.
Terminal velocities are shown for 150, 100 and
50 fpm. Throw data is without a ceiling.
All pressures are given in inches of water.
0, 22.5 and 45 represent blade deflection angles.

1200

1400

0.090 0.122
0.263 0.358
0.294 0.401
0.445 0.606
168
196
35
40
10-12-17 10-13-18
7-9-13 8-10-14
4-5-8
5-6-8
216
252
36
41
11-13-19 12-14-20
8-10-15 9-11-16
5-6-9
5-7-9
252
294
37
41
12-14-20 13-16-22
9-11-16 10-12-17
5-7-9
6-7-10
300
350
37
42
13-16-22 14-17-24
10-12-17 11-13-19
6-7-10 6-8-11
324
378
38
42
13-16-23 14-18-25
10-13-18 11-14-19
6-7-10 7-8-11
360
420
38
43
14-17-24 15-19-26
11-13-19 12-14-20
6-8-11 7-8-12
408
476
39
43
15-18-26 16-20-28
12-14-20 13-15-22
7-8-12 7-9-13
468
546
39
44
16-20-28 17-21-30
12-15-22 13-16-23
7-9-13 8-10-14
516
602
40
44
17-21-29 18-22-32
13-16-23 14-17-24
8-9-13 8-10-14
576
672
40
45
18-22-31 19-24-33
14-17-24 15-18-26
8-10-14 9-11-15
624
728
40
45
19-23-32 20-25-35
14-18-25 16-19-27
8-10-14 9-11-16

Performance data based on duct sizes


in bold, the performance varies slightly
for duct sizes not shown in bold.
When selecting larger supply grilles for
cooling purposes, see the topic, Procedure
to Obtain Catalog Throw Data in the section,
Engineering Guidelines of this catalog.

Specialized Grilles

PERFORMANCE DATA

Nominal Nominal
Core
Duct
Duct
Area
Size
Area
sq. ft
( in. )
sq. ft

0.69

0.59

28x4
18x6
36x3

0.75

0.63

20x6
12x10
30x4

0.83

0.66

32x4

0.89

0.71

1.00

0.88

30x6
18x10

1.25

1.11

36x6
18x12

1.50

1.35

30x8
24x10

1.67

1.49

36x8
24x12

2.00

1.82

36x10
30x12

2.50

2.29

36x12

3.00

2.75

24x6
18x8
12x12
36x4

300

400

0.006 0.010
0.016 0.029
0.018 0.033
0.028 0.049
177
236
8-12-17 11-14-20
6-9-13 9-11-15
4-5-8
5-6-9
189
252
8-13-18 12-14-20
7-10-14 9-11-16
4-6-8
5-7-9
198
264
9-13-18 12-15-21
7-10-14 9-11-16
4-6-8
5-7-9
213
284
9-13-19 13-15-22
7-10-15 10-12-17
4-6-8
6-7-10
264
352
10-15-21 14-17-24
8-11-16 11-13-19
4-7-9
6-8-11
333
444
11
11-17-23 16-19-27
9-13-18 12-15-21
5-7-11 7-9-12
405
540
12
12-18-26 17-21-30
10-14-20 13-16-23
6-8-12 8-10-13
447
596
12
13-19-27 18-22-31
10-15-21 14-17-24
6-9-12 8-10-14
546
728
13
14-21-30 20-25-35
11-16-23 16-19-27
6-10-14 9-11-16
687
916
14
16-24-34 22-28-39
12-18-26 17-21-30
7-11-15 10-12-18
825
1100
15
18-26-37 25-30-43
14-20-29 19-23-33
8-12-17 11-14-19

Performance data obtained in actual


application conditions - direct duct mounted
grille, 90 to airflow with no ceiling.
Terminal velocities are shown for 150, 100 and
50 fpm. Throw data is without a ceiling.
All pressures are given in inches of water.
0, 22.5 and 45 represent blade deflection angles.

500

600

700

800

1000

0.016
0.046
0.051
0.077
295
15
13-16-22
10-12-17
6-7-10
315
15
13-16-23
10-13-18
6-7-10
330
15
13-17-23
10-13-18
6-7-11
355
16
14-17-24
11-13-19
6-8-11
440
16
16-19-27
12-15-21
7-9-12
555
17
18-21-30
14-17-23
8-10-14
675
18
19-24-33
15-18-26
9-11-15
745
19
20-25-35
16-19-27
9-11-16
910
19
22-27-39
17-21-30
10-12-17
1145
20
25-31-44
19-24-34
11-14-20
1375
21
28-34-48
21-26-37
12-15-21

0.022
0.066
0.074
0.111
354
20
14-17-24
11-13-19
6-8-11
378
20
14-18-25
11-14-19
7-8-11
396
21
15-18-26
11-14-20
7-8-12
426
21
15-19-27
12-15-21
7-8-12
528
22
17-21-30
13-16-23
8-9-13
666
23
19-23-33
15-18-26
9-11-15
810
24
21-26-37
16-20-28
10-12-16
894
24
22-27-38
17-21-30
10-12-17
1092
25
25-30-43
19-23-33
11-14-19
1374
26
28-34-48
21-26-37
12-15-21
1650
27
30-37-52
23-29-41
14-17-24

0.031
0.090
0.100
0.152
413
25
15-18-26
12-14-20
7-8-12
441
25
16-19-27
12-15-21
7-9-12
462
25
16-20-28
12-15-21
7-9-12
497
26
17-20-29
13-16-22
7-9-13
616
26
18-23-32
14-18-25
8-10-14
777
27
21-25-36
16-20-28
9-11-16
945
28
23-28-40
18-22-31
10-13-18
1043
29
24-29-42
19-23-32
11-13-19
1274
30
27-32-46
21-25-36
12-15-21
1603
30
30-36-52
23-28-40
13-16-23
1925
31
33-40-56
25-31-44
15-18-25

0.040
0.117
0.131
0.198
472
29
16-20-28
13-15-22
7-9-13
504
29
17-20-29
13-16-22
8-9-13
528
29
17-21-30
13-16-23
8-9-13
568
30
18-22-31
14-17-24
8-10-14
704
30
20-24-34
15-19-26
9-11-15
888
31
22-27-38
17-21-30
10-12-17
1080
32
24-30-42
19-23-33
11-13-19
1192
33
26-31-44
20-24-34
12-14-20
1456
34
28-35-49
22-27-38
13-16-22
1832
34
32-39-55
25-30-43
14-18-25
2200
35
35-43-60
27-33-47
16-19-27

0.062
0.183
0.204
0.309
590
35
18-22-31
14-17-24
8-10-14
630
36
19-23-32
14-18-25
8-10-15
660
36
19-23-33
15-18-26
9-11-15
710
36
20-24-34
15-19-27
9-11-15
880
37
22-27-38
17-21-30
10-12-17
1110
38
25-30-43
19-23-33
11-14-19
1350
39
27-33-47
21-26-37
12-15-21
1490
39
29-35-50
22-27-38
13-16-22
1820
40
32-39-55
25-30-43
14-17-25
2290
41
36-44-62
28-34-48
16-20-28
2750
42
39-48-67
30-37-52
18-21-30

1200

1400

0.090 0.122
0.263 0.358
0.294 0.401
0.445 0.606
708
826
41
46
20-24-34 21-26-37
15-19-27 17-20-29
9-11-15 10-12-17
756
882
41
46
20-25-35 22-27-38
16-19-27 17-21-30
9-11-16 10-12-17
792
924
41
46
21-26-36 23-28-39
16-20-28 18-21-30
9-12-16 10-12-18
852
994
42
46
22-27-38 23-29-41
17-21-29 18-22-31
10-12-17 11-13-18
1056
1232
43
47
24-30-42 26-32-45
19-23-32 20-25-35
11-13-19 12-14-20
1332
1554
44
48
27-33-47 29-36-51
21-26-36 23-28-39
12-15-21 13-16-23
1620
1890
44
49
30-37-52 32-40-56
23-28-40 25-31-43
13-16-23 15-18-25
1788
2086
45
49
31-38-54 34-42-59
24-30-42 26-32-46
14-17-24 15-19-26
2184
2548
46
50
35-43-60 38-46-65
27-33-47 29-36-50
16-19-27 17-21-29
2748
3206
47
51
39-48-67 42-52-73
30-37-52 33-40-56
18-21-30 19-23-33
3300
3850
47
52
43-52-74 46-56-80
33-41-57 36-44-62
19-24-33 21-25-36

Performance data based on duct sizes


in bold, the performance varies slightly
for duct sizes not shown in bold.
When selecting larger supply grilles for
cooling purposes, see the topic, Procedure
to Obtain Catalog Throw Data in the section,
Engineering Guidelines of this catalog.

PERFORMANCE DATA

26x4
10x10
34x3

Core Velocity,
( fpm )
Velocity Pressure
Total
0
Pressure
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
0
Throw (Ft.)
22.5
45

www.titus-hvac.com | www.titus-energysolutions.com

S300F, US300F, S301F AND US301F SUPPLY WITH NO EXTRACTOR


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

I39

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

I40

S300F, US300F, S301F AND US301F SUPPLY WITH EXTRACTOR SET AT 45B ANGLE
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
Core Velocity, ( fpm )
Nominal Nominal
Core
Velocity Pressure
Duct
Duct
Area
Total
0
Size
Area
Pressure
22.5
sq. ft
( in. )
sq. ft
45
Airflow, cfm
NC
10x3
0.21
0.14
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
12x3
0.25
0.18
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
10x4
0.28
0.21
0
14x3
Throw (Ft.)
22.5
45
Airflow, cfm
16x3
NC
12x4
0.33
0.25
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
18x3
0.38
0.27
0
14x4
Throw (Ft.)
22.5
45
Airflow, cfm
10x6
NC
20x3
0.42
0.3
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
16x4
0.44
0.34
0
22x3
Throw (Ft.)
22.5
45
Airflow, cfm
24x3
NC
12x6
0.50
0.39
0
18x4
Throw (Ft.)
22.5
26x3
45
Airflow, cfm
14x6
NC
20x4
0.56
0.43
0
28x3
Throw (Ft.)
22.5
45
Airflow, cfm
NC
22x4
0.61
0.48
0
30x3
Throw (Ft.)
22.5
45
Airflow, cfm
32x3
NC
24x4
0.67
0.52
0
16x6
Throw (Ft.)
22.5
12x8
45

300
400
500
600
700
800
0.006
0.010
0.016
0.022
0.031
0.040
0.033
0.058
0.091
0.132
0.179
0.234
0.037
0.065
0.102
0.147
0.200
0.262
0.056
0.099
0.155
0.223
0.303
0.396
42
56
70
84
98
112
13
18
23
27
3-6-8
4-7-10
5-8-11
6-8-12
7-9-13
8-10-14
2-5-6
3-5-7
4-6-8
5-6-9
5-7-10
6-7-11
1-3-4
2-3-4
2-3-5
3-4-5
3-4-6
4-4-6
54
72
90
108
126
144
14
19
24
28
5-7-9
6-8-11
7-9-12
8-9-13
8-10-14 9-11-15
4-5-7
5-6-8
5-7-9
6-7-10
6-8-11
7-8-12
2-3-4
3-3-5
3-4-5
3-4-6
4-5-7
4-5-7
63
84
105
126
147
168
14
20
25
29
5-7-10
7-8-12
8-9-13
8-10-14 9-11-16 10-12-17
4-6-8
5-6-9
6-7-10
6-8-11
7-9-12
7-9-13
2-3-5
3-4-5
3-4-6
4-5-7
4-5-7
4-5-8
75
100
125
150
175
200
15
21
25
29
5-8-11
7-9-13
8-10-14 9-11-16 10-12-17 11-13-18
4-6-9
6-7-10
6-8-11
7-9-12
8-9-13
8-10-14
2-4-5
3-4-6
4-5-6
4-5-7
4-5-8
5-6-8
81
108
135
162
189
216
16
21
26
30
6-8-12
8-9-13
9-11-15 9-12-16 10-13-18 11-13-19
4-6-9
6-7-10
7-8-12
7-9-13
8-10-14 8-10-15
2-4-5
3-4-6
4-5-7
4-5-7
5-6-8
5-6-9
90
120
150
180
210
240
16
21
26
30
6-9-12 8-10-14 9-11-16 10-12-17 11-13-19 12-14-20
5-7-9
6-8-11
7-9-12
8-9-13
8-10-14 9-11-15
3-4-5
4-4-6
4-5-7
4-5-8
5-6-8
5-6-9
102
136
170
204
238
272
16
22
27
31
6-9-13 9-11-15 10-12-17 11-13-18 11-14-20 12-15-21
5-7-10
7-8-12
8-9-13
8-10-14 9-11-15 9-12-16
3-4-6
4-5-7
4-5-8
5-6-8
5-6-9
6-7-10
117
156
195
234
273
312
17
22
27
31
7-10-14 9-11-16 10-13-18 11-14-20 12-15-21 13-16-23
5-8-11
7-9-12
8-10-14 9-11-15 10-12-16 10-12-18
3-4-6
4-5-7
5-6-8
5-6-9
6-7-10
6-7-10
129
172
215
258
301
344
11
17
23
28
31
7-10-15 10-12-17 11-13-19 12-15-21 13-16-22 14-17-24
5-8-11
8-9-13
8-10-15 9-11-16 10-12-17 11-13-18
3-5-7
4-5-8
5-6-8
5-7-9
6-7-10
6-8-11
144
192
240
288
336
384
11
18
23
28
32
7-11-15 10-13-18 12-14-20 13-15-22 14-17-24 15-18-25
6-8-12 8-10-14 9-11-15 10-12-17 11-13-18 11-14-20
3-5-7
5-6-8
5-6-9
6-7-10
6-8-11
7-8-11
156
208
260
312
364
416
12
18
24
28
32
8-11-16 11-13-19 12-15-21 13-16-23 14-17-25 15-19-26
6-9-12 8-10-14 9-11-16 10-12-18 11-13-19 12-14-20
3-5-7
5-6-8
5-7-9
6-7-10
6-8-11
7-8-12

Performance data obtained in actual


application conditions - direct duct mounted
grille, 90 to airflow with no ceiling.
Terminal velocities are shown for 150, 100 and
50 fpm. Throw data is without a ceiling.
All pressures are given in inches of water.
0, 22.5 and 45 represent blade deflection angles.

1000
0.062
0.365
0.409
0.618
140
33
9-11-15
7-8-12
4-5-7
180
35
10-12-17
8-9-13
4-5-8
210
35
11-13-19
8-10-14
5-6-8
250
36
12-14-20
9-11-16
5-6-9
270
36
12-15-21
9-12-16
5-7-10
300
37
13-16-22
10-12-17
6-7-10
340
37
14-17-24
11-13-18
6-8-11
390
38
15-18-25
11-14-20
7-8-11
430
38
15-19-27
12-15-21
7-8-12
480
39
16-20-28
13-15-22
7-9-13
520
39
17-21-29
13-16-23
8-9-13

Performance data based on duct sizes


in bold, the performance varies slightly
for duct sizes not shown in bold.
When selecting larger supply grilles for
cooling purposes, see the topic, Procedure
to Obtain Catalog Throw Data in the section,
Engineering Guidelines of this catalog.

1200
0.090
0.526
0.589
0.891
168
39
10-12-17
7-9-13
4-5-8
216
40
11-13-19
8-10-15
5-6-9
252
41
12-14-20
9-11-16
5-7-9
300
41
13-16-22
10-12-17
6-7-10
324
42
13-16-23
10-13-18
6-7-10
360
42
14-17-24
11-13-19
6-8-11
408
43
15-18-26
12-14-20
7-8-12
468
43
16-20-28
12-15-22
7-9-13
516
44
17-21-29
13-16-23
8-9-13
576
44
18-22-31
14-17-24
8-10-14
624
44
19-23-32
14-18-25
8-10-14

Specialized Grilles

PERFORMANCE DATA

300
0.006
0.033
0.037
0.056
177
8-12-17
6-9-13
4-5-8
189
8-13-18
7-10-14
4-6-8
198
9-13-18
7-10-14
4-6-8
213
9-13-19
7-10-15
4-6-8
264
10-15-21
8-11-16
4-7-9
333
11-17-23
9-13-18
5-7-11
405
12-18-26
10-14-20
6-8-12
447
13-19-27
10-15-21
6-9-12
546
14-21-30
11-16-23
6-10-14
687
16-24-34
12-18-26
7-11-15
825
18-26-37
14-20-29
8-12-17

Performance data obtained in actual


application conditions - direct duct mounted
grille, 90 to airflow with no ceiling.
Terminal velocities are shown for 150, 100 and
50 fpm. Throw data is without a ceiling.
All pressures are given in inches of water.
0, 22.5 and 45 represent blade deflection angles.

400
0.010
0.058
0.065
0.099
236
12
11-14-20
9-11-15
5-6-9
252
12
12-14-20
9-11-16
5-7-9
264
13
12-15-21
9-11-16
5-7-9
284
13
13-15-22
10-12-17
6-7-10
352
14
14-17-24
11-13-19
6-8-11
444
15
16-19-27
12-15-21
7-9-12
540
16
17-21-30
13-16-23
8-10-13
596
16
18-22-31
14-17-24
8-10-14
728
17
20-25-35
16-19-27
9-11-16
916
18
22-28-39
17-21-30
10-12-18
1100
19
25-30-43
19-23-33
11-14-19

500
0.016
0.091
0.102
0.155
295
19
13-16-22
10-12-17
6-7-10
315
19
13-16-23
10-13-18
6-7-10
330
19
13-17-23
10-13-18
6-7-11
355
20
14-17-24
11-13-19
6-8-11
440
20
16-19-27
12-15-21
7-9-12
555
21
18-21-30
14-17-23
8-10-14
675
22
19-24-33
15-18-26
9-11-15
745
23
20-25-35
16-19-27
9-11-16
910
23
22-27-39
17-21-30
10-12-17
1145
24
25-31-44
19-24-34
11-14-20
1375
25
28-34-48
21-26-37
12-15-21

600
0.022
0.132
0.147
0.223
354
24
14-17-24
11-13-19
6-8-11
378
24
14-18-25
11-14-19
7-8-11
396
25
15-18-26
11-14-20
7-8-12
426
25
15-19-27
12-15-21
7-8-12
528
26
17-21-30
13-16-23
8-9-13
666
27
19-23-33
15-18-26
9-11-15
810
28
21-26-37
16-20-28
10-12-16
894
28
22-27-38
17-21-30
10-12-17
1092
29
25-30-43
19-23-33
11-14-19
1374
30
28-34-48
21-26-37
12-15-21
1650
31
30-37-52
23-29-41
14-17-24

700
0.031
0.179
0.200
0.303
413
29
15-18-26
12-14-20
7-8-12
441
29
16-19-27
12-15-21
7-9-12
462
29
16-20-28
12-15-21
7-9-12
497
30
17-20-29
13-16-22
7-9-13
616
30
18-23-32
14-18-25
8-10-14
777
31
21-25-36
16-20-28
9-11-16
945
32
23-28-40
18-22-31
10-13-18
1043
33
24-29-42
19-23-32
11-13-19
1274
34
27-32-46
21-25-36
12-15-21
1603
34
30-36-52
23-28-40
13-16-23
1925
35
33-40-56
25-31-44
15-18-25

800
0.040
0.234
0.262
0.396
472
33
16-20-28
13-15-22
7-9-13
504
33
17-20-29
13-16-22
8-9-13
528
33
17-21-30
13-16-23
8-9-13
568
34
18-22-31
14-17-24
8-10-14
704
34
20-24-34
15-19-26
9-11-15
888
35
22-27-38
17-21-30
10-12-17
1080
36
24-30-42
19-23-33
11-13-19
1192
37
26-31-44
20-24-34
12-14-20
1456
38
28-35-49
22-27-38
13-16-22
1832
38
32-39-55
25-30-43
14-18-25
2200
39
35-43-60
27-33-47
16-19-27

1000
0.062
0.365
0.409
0.618
590
39
18-22-31
14-17-24
8-10-14
630
40
19-23-32
14-18-25
8-10-15
660
40
19-23-33
15-18-26
9-11-15
710
40
20-24-34
15-19-27
9-11-15
880
41
22-27-38
17-21-30
10-12-17
1110
42
25-30-43
19-23-33
11-14-19
1350
43
27-33-47
21-26-37
12-15-21
1490
43
29-35-50
22-27-38
13-16-22
1820
44
32-39-55
25-30-43
14-17-25
2290
45
36-44-62
28-34-48
16-20-28
2750
46
39-48-67
30-37-52
18-21-30

Performance data based on duct sizes


in bold, the performance varies slightly
for duct sizes not shown in bold.
When selecting larger supply grilles for
cooling purposes, see the topic, Procedure
to Obtain Catalog Throw Data in the section,
Engineering Guidelines of this catalog.

1200
0.090
0.526
0.589
0.891
708
45
20-24-34
15-19-27
9-11-15
756
45
20-25-35
16-19-27
9-11-16
792
45
21-26-36
16-20-28
9-12-16
852
46
22-27-38
17-21-29
10-12-17
1056
47
24-30-42
19-23-32
11-13-19
1332
48
27-33-47
21-26-36
12-15-21
1620
48
30-37-52
23-28-40
13-16-23
1788
49
31-38-54
24-30-42
14-17-24
2184
50
35-43-60
27-33-47
16-19-27
2748
51
39-48-67
30-37-52
18-21-30
3300
51
43-52-74
33-41-57
19-24-33

PERFORMANCE DATA

Core Velocity, ( fpm )


Nominal Nominal
Core
Velocity Pressure
Duct
Duct
Area
Total
0
Size
Area
sq. ft
Pressure
22.5
( in. )
sq. ft
45
Airflow, cfm
26x4
NC
10x10
0.69
0.59
0
34x3
Throw (Ft.)
22.5
45
Airflow, cfm
28x4
NC
18x6
0.75
0.63
0
36x3
Throw (Ft.)
22.5
45
Airflow, cfm
20x6
NC
12x10
0.83
0.66
0
30x4
Throw (Ft.)
22.5
45
Airflow, cfm
NC
32x4
0.89
0.71
0
Throw (Ft.)
22.5
45
Airflow, cfm
24x6
NC
18x8
1.00
0.88
0
12x12
Throw (Ft.)
22.5
36x4
45
Airflow, cfm
30x6
NC
18x10
1.25
1.11
0
Throw (Ft.)
22.5
45
Airflow, cfm
36x6
NC
18x12
1.50
1.35
0
Throw (Ft.)
22.5
45
Airflow, cfm
30x8
NC
24x10
1.67
1.49
0
Throw (Ft.)
22.5
45
Airflow, cfm
36x8
NC
24x12
2.00
1.82
0
Throw (Ft.)
22.5
45
Airflow, cfm
36x10
NC
30x12
2.50
2.29
0
Throw (Ft.)
22.5
45
Airflow, cfm
NC
36x12
3.00
2.75
0
Throw (Ft.)
22.5
45

www.titus-hvac.com | www.titus-energysolutions.com

S300F, US300F, S301F AND US301F SUPPLY WITH EXTRACTOR SET AT 45B ANGLE
PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.

I41

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

Blades shall be constructed of heavy duty extruded


aluminum and shall be spaced -inch apart. Blades shall
extend completely through the side frame on each side
to ensure stability throughout the complete cfm operating
range of the grille. Blades shall be individually adjustable
without loosening or rattling and shall be securely held in
place with tension wire. (S8F: perforated face will have
3
/16-inch holes on -inch staggered centers.)

SPIRAL DUCT MOUNTED GRILLES


RADIUS END CAP
Available Single Deflection Models:
S301FL
S301FS
Available Double Deflection Models:
S300FL
S300FS

Optional air scoop damper/extractor (option ASD) shall be


constructed of heavy duty aluminum. The ASD must be
operable from the face with a screwdriver.

Available Perforated Model:


S8F
Aluminum supply grilles shall be Titus direct spiral ductmounted supply grilles model S301F (single deflection) or
S300F (double deflection) or S8F (perforated face) return
for the sizes and mounting types as shown on the plans
and outlet schedule. The deflection blades shall be available
parallel to the long or short dimension of the grille. All
supply grilles shall be constructed with radius end caps and
foam gaskets for a tight seal to the duct diameter. All supply
grilles shall be constructed with a 13/8-inch wide border.

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Height - Duct Dimensions (note 1)
6 thru 36
3
6 thru 36
4
8 thru 36
6
10 thru 36
Damper (note 2)
8
12 thru 36
None
10
0
14 thru 36
12
ASD Air Scoop Damper

Model
S301FL
S301FS
S300FL
S300FS
S8F
XXXXXX
Width
Specify 10
to 36

XX-XX

XX
Finish

White (std.)
Clear Anodized

XX

26
34

SPECIFICATIONS

Note 1: Specify in 2-inch increments. Example 03-12=3 inches high, 12-inch duct diameter.
Note 2: Damper not available with S8F.

I42

Specialized Grilles

SUGGESTED SPECIFICATIONS

UNIVERSAL END CAP


Available Single Deflection Models:
US301FL
US301FS
Available Double Deflection Models:
US300FL
US300FS

Optional air scoop damper/extractor (option ASD) shall be


constructed of heavy duty aluminum. The ASD must be
operable from the face with a screwdriver.

Available Perforated Model:


US8F
Aluminum supply grilles shall be Titus direct spiral ductmounted supply grilles model US301F (single deflection) or
US300F (double deflection) or US8F (perforated face) return
for the sizes and mounting types as shown on the plans
and outlet schedule. The deflection blades shall be available
parallel to the long or short dimension of the grille. All
supply grilles shall be constructed with end caps with foam
gaskets for a tight seal to any size duct diameter. All supply
grilles shall be constructed with a 1-inch wide border.

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Height - Duct Dimensions
6 thru 36
3
10 thru 36
4
12 thru 36
6
14 thru 36
8
16 thru 36
10
18 thru 36
12

Model
US301FL
US301FS
US300FL
US300FS
US8F
XXXXXXX

XX

XX

Width

Finish

Specify 10 to 36

White (std.)
Clear Anodized

www.titus-hvac.com | www.titus-energysolutions.com

Blades shall be constructed of heavy duty extruded


aluminum and shall be spaced -inch apart. Blades shall
extend completely through the side frame on each side
to ensure stability throughout the complete cfm operating
range of the grille. Blades shall be individually adjustable
without loosening or rattling and shall be securely held in
place with tension wire. (US8F: perforated face will have
3
/16-inch holes on -inch staggered centers.)

SPIRAL DUCT MOUNTED GRILLES

Damper (note)
None
0
ASD Air Scoop Damper
XX

26
34

Note: Damper not available with S8F.

SPECIFICATIONS
I43

Specialized Grilles

T-700
T-700(L/S) - STEEL
Available Models:
T-700L
T-700S
Products Include:
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#7 - Channel Frame
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws, Painted White.
T-700L
Sight proof.
Used in doors and partitions.
Included v-blades block vision
and provide extra strength.
20-gauge steel blades.
Blades parallel to the
long dimension.
T-700S
Same as T-700L with blades
parallel to the short dimension.

T-700

www.titus-hvac.com | www.titus-energysolutions.com

Door Grilles

Border Type 1 Surface Mount


D plus 2"
Type A
Fastening
External
Screw

1"

77 Deflection

"

3/16"

1"
D minus "
Duct Size D

Available sizes (D x D) Border Type 1 are 6 x 4 inches through 30 x 30 inches in 1-inch


increments.
Border Type 7 Channel Frame

"

9/32"

1"
D minus "
Available sizes (D x D) Border Type 1 are 6 x 4 inches through 30 x 30 inches in 1-inch
increments.
Auxiliary Frame

"

T-700

1" 2"

"
D plus 2"

I44

Available sizes (D x D) Border Type 1 are 6 x 4 inches through 30 x 30 inches in 1-inch


increments.

Specialized Grilles

Door Grilles (continued)

CT-700(L/S) - ALUMINUM

Products Include:
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount.
Countersunk Screw Holes.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screws, Painted White.
CT-700L
Sight proof.
Used in doors and partitions.
Included v-blades block vision
and provide extra strength.
Aluminum blades.
Blades parallel to the
long dimension.
CT-700S
Same as CT-700L with blades
parallel to the short dimension.

CT-700

Available Models:
CT-700L
CT-700S

Border Type 1 Surface Mount


D plus 2"
Type A
Fastening
External
Screw

1"

77 Deflection

"

3/16"

www.titus-hvac.com | www.titus-energysolutions.com

CT-700

1"
D minus "
Duct Size D

Available sizes (D x D) Border Type 1 are 6 x 4 inches through 30 x 30 inches in 1-inch


increments.

Auxiliary Frame
3/16"

1"

D plus 27/16"

2" Max.

3/16"

Available sizes (D x D) Border Type 1 are 6 x 4 inches through 30 x 30 inches in 1-inch


increments.

CT-700
I45

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

T-700 AND CT-700 DOOR GRILLES


PERFORMANCE BASED ON NOMINAL SIZES SHOWN IN BOLD.
NC 20
Nominal
Duct
Size
(in)
6x6

Nominal
Duct
Area
sq. ft
0.25

Core
Area
sq. ft

8x6

0.33

0.26

10x6

0.42

0.34

8x8

0.44

0.37

12x6

0.50

0.41

14x6

0.58

0.48

16x6
12x8

0.67

0.57

10x10

0.69

0.59

18x6
20x6
12x10

0.75

0.63

0.83

0.72

22x6
24x6
12x12
30x6
18x10

0.92

0.77

1.00

0.88

1.25

1.11

14x14

1.36

1.22

18x12

1.50

1.35

22x10
30x8
24x10
42x6
18x14
16x16

1.53

1.37

1.67

1.49

1.75
1.78

1.59
1.62

24x12
18x16
18x18

2.00

1.82

2.25

2.07

24x14

2.33

2.14

30x12

2.50

2.29

24x16

2.67

2.46

20x20

2.78

2.57

30x16
24x20

3.33

3.11

22x22

3.36

3.14

24x22

3.67

3.43

30x18

3.75

3.50

24x24

4.00

3.75

30x24

5.00

4.71

28x28

5.44

5.16

30x28

5.83

5.51

30x30

6.25

5.94

0.19

Core Velocity
Velocity Pressure
CT-700 Static Pressure
T-700 Static Pressure
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)
Airflow, cfm
NC (Noise Criteria)

NC 30

NC 40

200
250
300
350
400
450
500
550
600
0.003 0.004 0.006 0.008 0.010 0.013 0.016 0.019 0.022
0.028 0.044 0.063 0.086 0.113 0.143 0.176 0.213 0.254
0.027 0.043 0.062 0.084 0.110 0.139 0.172 0.208 0.247
38
48
57
67
76
86
95
105
114
15
20
24
27
30
32
34
36
38
52
65
78
91
104
117
160
143
156
39
16
21
25
28
31
33
36
38
68
85
102
119
136
153
170
187
204
29
18
22
26
32
35
37
39
41
204
222
74
93
111
148
167
185
130
39
18
23
26
30
32
35
37
41
82
103
123
144
164
185
205
246
226
18
23
27
30
33
35
38
40
41
96
120
144
168
192
216
240
264
288
19
24
28
32
34
37
39
41
43
143
171
200
228
257
285
314
342
114
20
24
28
31
34
36
38
40
42
118
148
177
207
236
266
295
325
354
20
25
28
32
34
37
39
41
43
126
158
189
221
252
284
315
347
378
39
20
25
29
32
35
37
41
43
288
324
396
432
144
180
216
252
360
29
21
25
33
35
38
40
42
44
154
193
270
308
347
385
424
462
231
21
26
30
33
36
38
40
42
44
176
220
264
308
352
396
440
484
528
39
22
26
30
33
36
41
43
45
222
278
333
389
444
555
611
666
500
23
27
31
34
37
40
42
44
46
244
305
366
437
488
549
610
671
732
23
28
32
358
38
40
42
44
46
270
338
405
473
540
608
675
743
810
47
24
28
32
35
38
41
43
45
274
343
411
480
548
617
685
754
822
24
28
32
35
38
41
43
45
47
298
373
447
522
596
671
745
820
894
24
28
32
35
38
41
43
45
47
318
398
477
557
636
716
795
875
954
24
29
33
36
39
41
43
45
47
324
405
486
567
648
729
810
891
972
29
24
33
36
39
41
44
46
47
364
546
637
728
819
910
1001
1092
455
39
25
30
33
37
42
44
46
48
414
518
621
725
932
10035 1139
1242
828
30
34
37
40
42
45
47
48
25
428
535
642
749
856
963
1070
1177
1284
26
30
34
37
40
42
45
47
49
458
573
687
802
916
1031
1145
1260
1374
26
31
34
38
40
43
45
47
49
493
615
738
861
984
1107
1230
1353
1476
26
31
35
38
41
43
45
47
49
514
643
771
900
1028 1157
1258
1414
1542
49
26
31
35
38
41
43
46
48
622
778
933
1089
1244 1400
1555
1711
1866
27
32
36
39
42
44
46
48
50
628
785
942
1099
1256 1413
1570
1727
1884
27
32
36
39
42
44
46
48
50
686
858
1029
1201
1372 1544
1715
1887
2058
28
32
36
39
42
45
47
49
51
700
875
1050
1225
1400 1575
1750
1925
2100
39
28
32
36
42
45
47
49
51
750
938
1125
1500 1688
1875
2063
2250
1313
49
28
33
36
40
43
45
47
51
942
1178 1413
1649
1884 2120
2355
2826
2591
29
34
37
41
43
46
48
50
52
1032
1290 1548
1806
2064 2322
2580
2838
2096
29
34
38
41
44
46
49
51
52
2755
3031
3306
1378 1653
1929
2204 2480
1102
30
34
38
41
44
47
49
51
53
1188
1485 1782
2079
2376 2673
2970
3267
3564
30
35
38
42
44
47
49
51
53
NC 50

I46

Static pressures are negative, in inches of water,


measured per ANSI/ASHRAE Standard 70-2006.

NC based on room absorption of 10dB, re 10-12 watts,


measured per ANSI/ASHRAE Standard 70-2006.

Specialized Grilles

SUGGESTED SPECIFICATIONS

Available Models:

T-700

CT-700

CT-700 ALUMINUM DOOR GRILLE


Steel
Aluminum

T-700 STEEL DOOR GRILLE

Door return grilles shall be Titus Model T-700 for the sizes
and mounting types as shown on the plans and outlet
schedule. Construction shall be of steel with a 1-inch
border width. The border and blades shall be of 20-gauge
steel. Inverted V-blades with a deflection angle of 77
shall be used to create a sight proof design and provide
additional stiffness to the grille. Corners shall be welded
with full penetration resistance welds with a reinforcing
patch for extra strength. Screw holes shall be countersunk
for a neat appearance.
The grille finish shall be #26 white. The finish shall be an
anodic acrylic paint, baked at 315 F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.

Door return grilles shall be Titus Model CT-700 for the


sizes and mounting types as shown on the plans and outlet
schedule. Outer borders shall be constructed of heavy
extruded aluminum with a thickness of 0.040 to 0.050inch and shall have countersunk screw holes for a neat
appearance. Border width shall be 1-inch on all sides and
shall be interlocked at the four corners and mechanically
staked to form a rigid frame.
Extruded aluminum inverted V-blades with a deflection
angle of 77 shall be used to create a sight proof design and
provide additional stiffness to the grille.
The grille finish shall be #26 white. The finish shall be an
anodic acrylic paint, baked at 315 F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

www.titus-hvac.com | www.titus-energysolutions.com

DOOR GRILLES

MODEL NUMBER SPECIFICATION


Model
T-700
CT-700

Width
Steel
Aluminum

XXXXX

Parallel to Long
Dimension

Parallel to Short
Dimension

Border Type
Surface Mount
1
Channel Frame
7

X
Height

Optional Auxiliary
Frame
Border Type 1 Only

AF

XX

XX

X
White (std.)
Aluminum
Mill

26
01
04
Finish

Blade Orientation

SPECIFICATIONS
I47

Specialized Grilles

1700 (L, S)
NARROW BLADE GRILLES
1700 (L, S)

www.titus-hvac.com | www.titus-energysolutions.com

Reversible Core

Available Models:
1700L
1700S
Products Include:
Standard Finish - #26 White.
Available Border Types:
#1 - Surface Mount
#8 - Core Only
C - Curved Borders
#8 x 11/4-inch long Phillips Flat Head
Sheet Metal Screws, Painted White.
Optional 07 Directional Blades.
Optional Opposed Blade Damper.
Can be used as supply or return.

Titus 1700 Series grilles include:


Extreme flexibility in adjusting
airflow patterns. The fixed blade
core can be lifted out, then
rotated or reversed, to give four
different vertical deflection angles
as shown in the illustration below.
In addition, the optional Model
07 back blades can be adjusted
individually for various horizontal
deflection angles.

Remove, invert or reverse


the core for four different
vertical deflections.
With its deep, rigid aluminum
blades and carefully contoured
aluminum border, the Titus 1700
Series offers a look of refinement
backed with strength, versatility
and superb performance.

1700L/1700S Border Type 1


D plus 1"

D minus "
1"

Blades
07 Directional
Optional
Damper
Opposed Blade
Optional

5/16"

"

2"
15

3"

D minus "
Nominal Duct Size D"

Available sizes (D x D) Border Type are 6 x 4 inches (1700L) or 6 x 6 inches (1700S)


through 72 x 24 inches in single core construction or through 72 x 36 inches in multiple core
construction in 1-inch increments.
Four Different Vertical Deflections Chosen by Positioning Core

Core is easily removed with


one pull on the detachable
operating lever, as shown.
5
/32-inch mounting holes are
concealed inside the border,
accessible by removing the core.

Border Type C

2"
"
1"

Border Type 8 (Core Only)

1700 (L, S)

"

I48

Core Removal and Replacement

Supplied with Blades = D minus


25
/32-inch ,Tubes = D minus
-inch

To replace core, insert operating lever through blades, hook over mullion and
push downward on lever.

Specialized Grilles

Core
Area,
sq. ft.

0.18

0.26

0.34

0.39

0.52

0.60

0.69

0.81

0.90

1.07

1.34

1.60

1.80

300
0.006
0.017
0.019
0.020
55

4-7-13
3-6-10
2-3-7
80

5-8-16
4-6-13
3-4-8
100

5-10-18
4-7-14
3-4-9
115

6-10-19
5-7-15
3-5-10
155

7-12-23
6-10-18
3-5-11
180

7-13-24
6-11-19
4-6-12
205

8-14-26
6-11-21
4-6-13
245

8-15-28
6-12-22
4-7-14
270

10-16-30
7-13-24
5-8-15
320

11-17-32
8-14-26
5-8-16
355

11-18-34
8-15-27
5-8-17
400

12-19-36
10-15-29
6-10-18
480

14-21-40
11-17-32
6-11-20
540

400
0.010
0.028
0.031
0.034
70

6-8-15
5-6-12
3-4-8
105

7-12-19
6-10-15
4-5-9
135

8-13-21
6-11-17
4-6-11
155

10-14-23
7-11-18
4-6-11
210

11-16-26
8-13-21
5-7-13
240

12-17-28
10-14-22
5-8-14
275

13-18-30
11-15-24
6-10-15
325

14-20-33
11-16-26
6-10-16
360

15-21-34
12-17-27
7-11-17
430

16-23-38
13-19-30
7-12-19
470

16-24-40
13-19-32
8-12-20
535

17-25-42
14-20-34
8-13-21
640

19-28-46
15-22-37
10-14-23
720

500
0.016
0.045
0.050
0.054
90

7-12-17
6-10-14
4-5-9
130

10-14-21
7-11-17
4-7-10
170

11-16-24
8-13-19
5-8-12
195

12-17-25
10-14-20
5-8-13
260
11
14-20-29
11-16-23
6-10-15
300
12
15-21-31
12-17-25
7-11-16
345
12
16-23-34
13-19-27
7-12-17
405
13
17-24-37
14-19-30
8-13-18
450
14
18-26-39
15-21-31
10-14-19
535
14
19-30-42
15-23-34
10-15-21
590
14
20-30-44
16-23-35
11-15-22
670
15
21-32-47
17-25-38
11-16-23
800
16
22-34-51
19-28-41
12-17-25
900
17

600
0.022
0.062
0.068
0.075
110
12
10-14-19
7-11-15
4-7-10
155
13
11-17-23
8-14-18
5-8-11
205
14
13-20-26
11-16-22
6-10-13
235
15
14-20-28
11-16-22
7-11-14
310
16
16-23-32
13-19-26
8-12-16
360
17
17-25-34
14-20-27
8-13-17
415
17
19-27-37
15-22-30
10-14-18
485
18
20-29-40
16-23-32
11-15-20
540
19
22-31-42
18-25-34
11-16-21
640
19
23-35-46
19-28-37
12-18-23
710
19
24-37-48
19-30-38`
13-18-24
805
20
25-39-51
20-32-41
13-19-26
960
21
29-41-56
23-33-45
14-21-28
1080
22

700
0.030
0.084
0.093
0.102
125
17
11-15-20
8-12-16
5-7-10
180
18
13-17-24
11-14-19
6-9-12
240
19
15-20-28
12-16-22
7-10-14
275
20
16-22-30
13-18-24
8-11-15
365
21
19-25-35
15-20-28
10-12-17
420
22
20-27-37
16-22-30
11-13-19
485
22
22-29-40
18-23-32
11-14-20
565
23
24-31-43
19-25-34
12-15-22
630
24
25-33-45
20-26-36
13-16-23
750
24
28-36-46
22-29-39
14-18-25
825
24
29-38-52
23-30-42
14-19-26
940
25
30-40-56
23-32-45
15-20-28
1120
26
33-43-60
27-34-48
16-22-30
1260
27

800
0.040
0.112
0.124
0.136
145
21
12-16-22
10-13-18
6-8-11
210
22
15-19-26
12-15-21
7-9-13
270
23
17-22-30
14-18-24
8-11-15
310
24
18-23-32
15-18-26
10-12-16
415
25
21-26-37
17-21-30
11-13-18
480
26
23-29-40
19-23-321
12-14-20
550
26
25-31-43
20-25-34
13-15-21
650
27
27-33-46
22-26-37
14-17-23
720
28
28-35-48
23-28-38
15-17-24
855
28
31-38-53
24-30-42
15-19-26
945
28
33-40-56
27-32-45
16-20-28
1070
29
34-43-59
28-34-47
17-21-29
1280
30
37-46-64
30-37-51
18-23-32
1440
31

1000
0.062
0.174
0.192
0.211
180
27
14-17-24
11-14-19
7-9-12
260
28
17-21-29
14-17-23
8-11-15
340
29
20-24-33
16-19-26
10-12-17
390
30
21-26-36
17-21-29
11-13-18
520
31
24-30-41
19-24-33
12-15-21
600
32
26-32-45
21-26-36
13-16-22
690
32
28-34-47
22-27-38
14-17-24
810
33
30-37-51
24-30-41
15-19-26
900
34
32-39-55
26-31-44
16-20-27
1070
34
35-43-59
28-34-47
17-21-29
1180
34
36-45-62
29-36-50
18-22-31
1340
35
39-47-65
31-38-52
19-23-33
1600
36
42-51-72
34-41-58
21-26-36
1800
37

1200
0.090
0.252
0.279
0.306
215
33
15-19-26
12-15-21
8-10-13
310
34
19-23-32
15-18-26
9-12-16
410
35
22-26-37
18-21-30
11-13-18
470
36
23-27-40
18-22-32
12-14-20
625
37
27-33-45
22-26-36
13-16-23
720
38
29-35-48
23-28-38
14-17-24
830
38
30-38-52
24-30-42
15-19-26
970
39
33-41-56
26-33-45
17-20-28
1080
40
35-43-59
28-34-47
17-21-29
1280
40
38-46-64
30-37-51
19-23-32
1420
40
40-48-67
32-38-50
20-24-34
1610
41
42-52-72
34-42-58
21-26-36
1920
42
46-56-79
37-45-63
23-28-39
2160
43

1400
0.122
0.341
0.378
0.415
250
38
17-21-29
14-17-23
8-10-14
365
39
20-25-35
16-20-2
10-13-17
475
40
23-28-40
18-22-32
12-14-20
545
41
25-30-42
20-24-34
12-15-21
730
42
29-35-49
23-28-39
14-18-24
840
43
31-38-52
25-30-42
15-19-26
965
43
33-40-56
26-32-45
16-20-28
1130
44
36-44-60
29-35-48
18-22-30
1260
45
37-46-63
30-37-50
19-23-32
1500
45
41-50-69
33-40-55
20-25-35
1650
45
43-52-73
34-42-58
21-26-36
1880
46
45-56-78
36-45-62
23-28-39
2240
47
49-61-85
39-49-68
25-30-43
2520
48

14-22-42 20-30-48 25-37-55 31-45-59 34-46-63 39-49-68 45-55-76 48-60-84 52-65-90


11-18-34 16-23-38 20-30-44 24-36-47 28-37-50 32-39-54 36-44-61 38-48-67 42-52-72
7-12-21 10-15-24 13-18-27 15-22-29 17-23-32 20-24-34 22-27-38 24-30-42 26-32-45

Performance notes apprear at end of table.

PERFORMANCE DATA

1.18

Core Vel.
Nominal
Vel. Press.
Duct
0
Size, Total
22
inches Pres.
45
cfm
8X4
NC
7X5
0
6 X 6 Throw, ft. 22
45
cfm
12 X 4
NC
10 X 5
0
8 X 6 Throw, ft. 22
45
cfm
16 X 4
NC
12 X 5
0
10 X 6 Throw, ft. 22
45
cfm
18 X 4
NC
14 X 5
0
12 X 6 Throw, ft. 22
8X8
45
cfm
24 X 4
NC
18 X 5
0
16 X 6 Throw, ft. 22
45
28 X 4
cfm
NC
20 X 5
0
18 X 6
Throw, ft. 22
12 X 8
45
10 X 10
cfm
30 X 4
NC
24 X 5
20 X 6
0
14 X 8 Throw, ft. 22
12 X 10
45
cfm
36 X 4
NC
28 X 5
22 X 6
0
16 X 8 Throw, ft. 22
14 X 10
45
40 X 4
cfm
30 X 5
NC
26 X 6
0
18 X 8
16 x 10 Throw, ft. 22
45
12 X 12
cfm
48 X 4
NC
36 X 5
30 X 6
0
18 X 10 Throw, ft. 22
14 X 12
45
cfm
34 X 6
NC
24 X 8
20 X 10
0
16 X 12 Throw, ft. 22
14 X 14
45
cfm
60 X 4
NC
48 X 5
36 X 6
0
18 X 12 Throw, ft. 22
16 X 14
45
72 X 4
cfm
30 X 8
NC
24 X 10
0
22 X 12
18 x 14 Throw, ft. 22
45
16 X 16
cfm
60 X 5
NC
48 X 6
36 X 8
0
30 X 10 Throw, ft.
24 x 12
22
20 x 14
18 X 16
45

NC 30

www.titus-hvac.com | www.titus-energysolutions.com

NC 20

1700 SUPPLY

NC 40

PERFORMANCE DATA

I49

Specialized Grilles

1700 SUPPLY
NC 20

300
400
500
600
700
0.006
0.010
0.016
0.022
0.030
0.017
0.028
0.045
0.062
0.084
0.019
0.031
0.050
0.068
0.093
0.020
0.034
0.054
0.075
0.102
625
830
1040
1250
1460

17
22
27
15-24-45 21-32-52 28-40-58 32-47-63 37-49-68
12-19-36 17-25-42 22-32-46 25-37-50 30-39-54
7-12-23 11-16-26 14-20-29 16-23-32 18-25-34

800
1000
0.040
0.062
0.112
0.174
0.124
0.192
0.136
0.211
1660
2080
31
37
42-53-73 48-59-82
34-42-58 38-47-66
22-26-37 24-29-41

1200
0.090
0.252
0.279
0.306
2500
43
52-64-90
42-51-72
26-32-45

1400
0.122
0.341
0.378
0.415
2910
48
56-69-97
45-55-78
28-35-48

cfm
48 X 8
NC
32 X 12
0
26 X 14
24 X 16 Throw, ft. 22
20 x 18
45
20 X 20
cfm
36 X 12
NC
30 X 14
26 X 16
0
24 X 18 Throw, ft. 22
22 X 20
45
cfm
48 X 10
NC
26 X 18
0
24 X 20
40 X 12 Throw, ft. 22
36 x 14
45
30 X 16
cfm
24 X 24
NC
60 X 10
48 X 12
0
36 X 16 Throw, ft. 22
30 x 18
45
cfm
72 X 10
NC
48 X 16
0
36 X 20
30 X 24 Throw, ft. 22
45
cfm
72 X 12
NC
60 X 14
0
48 X 18
36 X 24 Throw, ft. 22
45

735
980
1220
1470
1720

11
18
23
28
16-27-49 23-35-57 29-42-62 34-51-68 40-54-74
13-21-39 19-28-46 23-34-50 28-40-54 32-43-59
7-13-24 12-17-28 15-21-31 17-25-34 20-27-37

1960
2450
32
38
46-57-80 52-64-89
36-46-64 45-51-71
23-28-40 26-32-45

2940
44
57-70-97
46-56-78
28-35-49

3430
49
61-76-106
49-61-85
32-38-53

835

17-28-52
14-22-42
8-14-26
935

18-29-55
15-23-44
8-15-28

1110
11
24-36-60
19-29-48
13-18-30
1240
12
25-38-63
11-31-50
13-19-31

1390
18
31-45-67
24-36-54
15-22-33
1560
19
36-48-71
29-38-57
18-23-35

1670
23
37-53-73
30-42-58
18-27-37
1870
24
43-56-78
35-42-62
21-28-39

1950
28
42-57-79
34-46-63
21-28-40
2180
29
50-60-84
40-48-67
23-30-42

2220
32
48-57-79
38-49-68
24-30-42
2490
33
51-64-90
40-51-72
26-32-45

2780
3340
38
44
55-68-95 60-75-104
44-54-76 48-60-83
28-34-47 30-37-52
3110
3730
39
45
58-72-100 64-79-110
46-58-80 51-63-88
29-36-50 32-40-55

3890
49
65-81-112
52-65-90
33-40-56
4350
50
69-86-118
55-69-94
35-43-59

1080

19-31-59
15-24-47
10-15-29
1400

21-35-67
17-28-54
11-17-33
1670

23-38-73
19-31-58
12-19-37

1440
13
28-40-68
22-32-54
14-20-34
1860
14
31-46-78
24-36-62
16-23-39
2230
15
33-50-85
27-40-68
17-24-43

1800
20
34-50-76
28-40-61
17-24-38
2320
21
38-57-87
31-46-70
19-29-43
2790
22
42-63-95
34-50-76
21-32-48

2170
25
40-59-84
32-48-67
20-30-42
2790
26
47-69-95
37-55-76
23-34-48
3350
27
50-76-104
40-61-83
24-38-52

2530
30
47-65-90
37-52-72
23-32-45
3260
31
54-74-103
43-59-82
27-37-52
3910
32
58-81-113
47-65-90
30-41-57

2890
34
54-69-97
43-55-78
27-35-48
3720
35
61-79-110
49-63-88
31-40-55
4460
36
67-87-122
53-70-98
33-44-61

3610
40
63-78-108
50-62-86
31-39-54
4650
41
72-89-123
58-71-98
36-44-61
5580
42
79-97-135
63-78-108
39-49-67

5050
51
75-93-128
60-74-102
38-46-64
6510
52
86-105-146
69-84-117
43-52-73
7810
53
93-116-160
74-93-130
47-58-80

2.45

3.11

3.61

4.65

PERFORMANCE DATA

5.58

I50

NC 40

Core Vel.
Nominal
Vel. Press.
Duct
0
Size, Total
22
inches Pres.
45
cfm
20 X 16
NC
18 X 18
0
40
X
8
2.08 36 X 10
Throw, ft. 22
30 x 12
45
24 X 14

Core
Area,
sq. ft.

2.78

NC 30

When used as a return, add 7 NC to the NC value


shown in the supply table. The negative static
pressure is 2.4 times the velocity pressure shown.

4330
46
69-86-118
55-69-94
35-43-59
5580
47
79-97-135
63-78-108
39-49-67
670
48
87-107-148
70-86-118
43-53-74

Each NC value is based on grille operation


at a 0B deflection. If the 07 Blades are
adjusted to 22B or 45, Increase the stated
sound levels by 1 or 7 NC respectively.
See the section, Engineering Guidelines,
in this catalog for throw information.

NC 50

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

Specialized Grilles

SUGGESTED SPECIFICATIONS

NARROW BLADES
Available Model:
1700
Supply grilles shall be Titus Model 1700 of the sizes and
mounting types shown on the plans and outlet schedule.
The fixed deflection blades shall be available parallel to the
long or short dimension of the grille. Outer borders shall be
constructed of heavy extruded aluminum with a thickness
of 0.040 to 0.050 inch. The 5/32-inch diameter screw holes
shall not be located on the face of the grille but shall be
concealed inside the border and accessible by removing the
core. The border width shall be 1-inch on all sides and shall
be interlocked at the four corners and mechanically staked
to form a rigid frame.
The grille core shall be constructed of heavy extruded
aluminum and shall be removable and reversible for

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel or aluminum.
The grille finish shall be #26 white. The finish shall be an
anodic acrylic paint, baked at 315 F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Width

Model
1700
XXXX

Parallel to Long
Dimension

Parallel to Short
Dimension

Border Type
Surface Mount
1
Core Only
8
Curved Border
C

X
Height

Optional Damper
Steel
AG-35
Aluminum AG-35-AA
26
White
(std.)

Finish

XX-XX-XX

www.titus-hvac.com | www.titus-energysolutions.com

obtaining a discharge deflection angle of 15 up, 15 down,


5 up or 5 down. Core shall be easily removable by pulling
on the detachable operating lever to provide access to
optional 07 directional blades or the optional opposed-blade
damper.

REVERSIBLE CORE GRILLES

XX
07
Optional
Directional
Blades

Blade Orientation

SPECIFICATIONS
I51

Specialized Grilles

Available Models:
JFA-L
JFA-S
Products Include:
Standard Finish #26 White.
Available Border Type
#1 - Surface Mount.
#8 x 1-inch long Phillips Flat Head
Sheet Metal Screw, Painted White.
Countersunk Screw Holes.
Optional Steel Opposed-Blade Damper.

JFA

JFA(L/S) - POLE OPERATED

JFA-L
Individually adjustable
extruded aluminum front
blades, -inch centers.
Steel rear blades
gang operated.
Pole operator handle
for adjusting rear blades.
Blades parallel to the
long dimension.
20-gauge steel frame.
JFA-S
Same as JFA-L with blades
parallel to the short dimension.

Pole Operated JFA-L/JFA-S Border Type 1


Optional opposed blade damper

Duct plus 1"


Duct minus "

JFA

Duct (36" Max.)

www.titus-hvac.com | www.titus-energysolutions.com

Commercial/Industrial Louvered Supply Grilles

" Dia.

1"

Gang
Operated
Blades

Duct plus 1"


Duct minus "
"

1"

"

5"

Operator Handle

Duct minus "


Duct minus 1/16"
Duct (36" Max.)

JFA (L, S)

Available sizes (D x D) Border Type 1 are 10 x 6 inches to 40 x 36 inches in 2-inch increments.

I52

Changes in activity in the conditioned space may require frequent changes in airflow
pattern from the supply outlets. Or, the changeover from heating to cooling may call
for a shift from a low deflection angle to a high one. In these situations, pole operated
supply grilles are time savers. The adjusting lever can be moved with a pole from the
floor without a ladder.

Specialized Grilles

PERFORMANCE DATA

NC 20

NC 30

NC 40

300
0.006
0.010

400
0.010
0.017

500
0.016
0.028

600
0.022
0.038

700
0.030
0.052

800
0.040
0.069

1000
0.062
0.107

1200
0.090
0.156

1400
0.122
0.211

0.011

0.019

0.031

0.043

0.058

0.078

0.120

0.175

0.237

0.016

0.029

0.047

0.064

0.088

0.117

0.181

0.263

0.356

cfm
NC
0
22
45
cfm
NC
0
22
45
cfm
NC
0
22
45
cfm
NC
0
22
45
cfm
NC
0
22
45
cfm
NC
0
22
45
cfm
NC
0
22
45
cfm
NC
0
22
45
cfm
NC
0
22
45

45

4-6-12
3-5-10
2-3-6

60

5-8-14
4-6-11
3-4-7

75

7-10-16
6-8-13
3-5-8

90

8-12-17
6-10-14
4-6-9

105
120
150
180
210
13
17
23
29
34
9-13-19 11-14-20 13-16-22 14-17-24 15-19-26
7-10-15 9-11-16 10-13-18 11-14-19 12-15-21
5-7-9
5-7-10
6-8-11 7-9-12
8-9-13

55

4-7-13
3-6-10
2-3-7

70

6-8-15
5-6-12
3-4-8

90

7-11-17
6-9-14
4-5-9

110
125
145
180
250
215
10
15
19
25
31
36
9-13-19 10-15-20 11-16-22 14-17-24 15-19-26 17-21-29
7-10-15 8-12-16 9-13-18 11-14-19 12-15-21 14-17-23
4-7-10
5-7-10
6-8-11
7-9-12 8-10-13 8-10-14

65

4-7-14
3-6-11
2-4-7

90

7-10-17
6-8-14
3-5-9

110

8-12-19
6-10-15
4-6-10

130
155
175
220
265
310
10
15
19
25
31
36
9-15-21 11-16-23 13-17-24 16-19-27 17-21-29 19-23-32
7-12-17 9-13-18 10-14-19 13-15-22 14-17-23 15-18-26
5-7-10
6-8-11
6-9-12 8-10-13 9-11-15 9-12-16

80

5-8-16
4-6-13
3-4-8

105

7-11-19
6-9-15
4-5-9

130
155
180
210
260
310
365

11
16
20
26
32
37
9-13-21 10-16-23 12-17-24 14-19-26 17-21-29 19-23-32 20-25-35
7-10-17 8-13-18 10-14-19 11-15-21 14-17-23 15-18-26 16-20-28
7-9-13 8-11-15 9-12-16 10-13-17
4-7-10
5-8-11
6-9-12

100

5-9-18
4-7-14
3-4-9

135
170
205
240
340
410
475
270

12
17
21
27
33
38
8-12-21 10-15-24 12-19-26 14-20-28 16-22-30 20-24-33 22-26-37 23-28-40
6-10-17 8-12-19 10-15-21 11-16-22 13-18-24 16-19-26 18-21-30 18-22-32
4-6-11
5-8-12
6-9-13 7-10-14 8-11-15 10-12-17 11-13-18 12-14-20

115

6-9-19
5-7-15
3-5-10

155
195
235
275
310
390
470
545

13
18
22
28
34
39
9-13-23 11-16-25 13-19-28 15-22-30 17-23-32 21-26-36 23-27-40 25-30-42
7-10-18 9-13-20 10-15-22 12-18-24 14-18-26 17-21-29 18-22-32 20-24-34
4-6-11
5-8-13 7-10-14 8-11-15 9-12-16 11-13-18 12-14-20 12-15-21

140

7-10-22
6-8-18
3-5-11

185
230
275
320
370
460
550
645

13
18
22
28
34
39
9-14-25 12-17-27 14-22-30 16-23-32 19-25-35 23-27-39 25-31-43 27-33-46
7-11-20 10-14-22 11-18-24 13-18-26 15-20-28 18-22-31 20-25-34 22-26-37
5-7-12
6-9-14 7-11-15 8-11-16 10-13-17 11-14-20 12-15-21 14-17-23

0.15

0.18

0.22

7X4
6X5

8X4
7X5
6X6

10X 4
8X 5
7X6

Throw, ft.

Throw, ft.

Throw, ft.

0.26

12 X 4
10 X 5
8 X 6 Throw, ft.

0.34

16 X 4
12 X 5
10 X 6 Throw, ft.

0.39

18 X 4
14 X 5
12 X 6
Throw, ft.
8X8

0.46

20
16
14
10

0.60

28x4
20x5
18x6
12x8 Throw, ft.
10x10

0.69

30x4
24x5
20x6
14x8 Throw, ft.
12x10

X
X
X
X

4
5
6
Throw, ft.
8

180
240
300
360
420
480
600
720
840

10
15
20
24
30
36
41
7-12-24 11-16-28 14-20-31 16-24-34 19-27-37 22-29-40 26-32-45 29-35-48 31-38-52
6-10-19 9-13-22 11-16-25 13-19-27 15-22-30 18-23-32 21-26-36 23-28-38 25-30-42
4-6-12
5-8-14 7-10-16 8-12-17 10-13-19 11-14-20 13-16-22 14-17-24 15-19-26
205
275
345
415
485
550
690
830
965

10
15
20
24
30
36
41
8-13-26 12-17-30 15-22-34 18-26-37 21-29-40 24-31-43 28-34-47 30-38-52 33-40-56
6-10-21 10-14-24 12-18-27 14-21-30 17-23-32 19-25-34 22-27-38 24-30-42 26-32-45
4-6-13
6-9-15 7-11-17 9-13-18 10-14-20 12-15-21 14-17-24 15-19-26 16-20-28

Performance notes apprear at end of table.

PERFORMANCE DATA

Core Vel.
Core Nominal
Vel. Press.
Area, Duct
0
sq.
Size,
22
Total
ft.
inches
Pres.
45

www.titus-hvac.com | www.titus-energysolutions.com

JFA SUPPLY

I53

Specialized Grilles

PERFORMANCE DATA

I54

JFA SUPPLY
NC 20
Core Vel.
Core Nominal
Vel. Press.
Area, Duct
0
sq.
Size,
22
Total
ft.
inches
Pres.
45
cfm
36x4
NC
28x5
0.81
22x6
0
16x8 Throw, ft. 22
14x10
45
cfm
40x4
30x5
NC
26x6
0.90
0
18x8
16x10 Throw, ft. 22
12x12
45
cfm
48x4
NC
36x5
1.07
30x6
0
18x10 Throw, ft. 22
14x12
45
cfm
34x6
NC
24x8
1.18 20x10
0
16x12 Throw, ft. 22
14x14
45
cfm
60x4
NC
48x5
1.34
36x6
0
18x12 Throw, ft. 22
16x14
45
cfm
72x4
30x8
NC
24x10
1.60
0
22x12
18x14 Throw, ft. 22
16x16
45
cfm
60x5
48x6
NC
36x8
30x10
1.80
0
24x12
Throw,
ft.
22
20x14
18x16
45
cfm
60x6
40x8
NC
36x10
30x12
2.08
0
24x14
20x16 Throw, ft. 22
18x18
45
cfm
72x6
48x8
NC
32x12
26x14
2.45
0
24x16
Throw,
ft.
22
20x18
20x20
45

NC 30

NC 40

300
0.006
0.010
0.011
0.016

400
0.010
0.017
0.019
0.029

500
0.016
0.028
0.031
0.047

600
0.022
0.038
0.043
0.064

700
0.030
0.052
0.058
0.088

800
0.040
0.069
0.078
0.117

1000
0.062
0.107
0.120
0.181

1200
0.090
0.156
0.175
0.263

1400
0.122
0.211
0.237
0.356

245

325

405

485

565

650

810

970

1130

11

16

21

25

31

37

42

8-14-28 13-19-33 16-23-37 19-28-40 23-31-43 26-33-46 30-37-51 33-41-56 36-44-60


6-11-22 10-15-26 13-18-30 15-22-32 18-25-34 21-26-37 24-30-41 26-33-45 29-35-48
4-7-14
6-9-16 8-12-18 10-14-20 11-15-22 13-17-23 15-19-26 17-20-28 18-22-30
270

360

450

540

630

720

900

1080

1260

11

16

21

25

31

37

42

9-15-30 14-20-34 17-25-39 21-30-42 24-33-45 27-35-48 32-39-55 35-43-59 37-46-63


7-12-24 11-16-27 14-20-31 17-24-34 19-26-36 2-28-38 26-31-44 28-34-47 30-37-50
5-8-15 7-10-17 9-13-19 10-15-21 12-16-23 14-17-24 16-20-27 17-21-29 19-23-32
320

430

535

640

750

855

1070

1280

1500

11

16

21

25

31

37

42

10-16-32 15-22-38 18-28-42 22-33-46 26-36-49 29-38-53 35-43-59 38-46-64 41-50-69


8-13-26 12-18-30 14-22-34 18-26-37 21-29-39 23-30-42 28-34-47 30-37-51 33-40-55
5-8-16 7-11-19 9-14-21 11-17-23 13-18-25 14-19-26 17-21-29 19-23-32 20-25-35
355

470

590

710

825

945

1180

1420

1650

12

17

22

26

32

38

43

10-17-34 15-23-40 19-28-44 23-35-48 27-38-52 31-40-56 36-45-62 40-48-67 43-52-73


8-14-27 12-18-32 15-22-35 18-28-38 22-30-42 25-32-45 29-36-50 32-38-54 34-42-58
5-8-17 8-11-20 10-14-22 12-17-24 13-19-26 15-20-28 18-22-31 20-24-34 21-26-36
400

535

670

805

940

1070

1340

1610

1880

13

18

23

27

33

39

44

11-18-36 16-24-42 20-30-47 24-37-51 28-40-56 32-43-59 39-47-65 42-52-72 45-56-78


9-14-29 13-19-34 16-24-38 19-30-41 22-32-45 26-34-47 31-38-52 34-42-58 36-45-62
6-9-18 8-12-21 10-15-23 12-18-25 14-20-28 16-21-29 19-23-33 21-26-36 23-28-39
480

640

800

960

1120

1280

1600

1920

2240

13

18

23

27

33

39

44

13-20-40 18-26-46 22-32-51 27-39-56 31-43-60 35-46-64 42-51-72 46-56-79 49-63-85


10-16-32 14-21-37 18-26-41 22-31-45 25-34-48 28-37-51 34-41-58 37-45-63 39-49-68
6-10-20 9-13-23 11-16-25 13-20-28 15-22-30 17-23-32 21-26-36 23-28-39 25-30-43
540

720

900

1080

1260

1440

1800

2160

2520

14

19

24

28

34

40

45

13-21-42 19-28-48 24-35-55 29-43-59 32-46-63 37-49-68 45-55-76 48-60-84 52-65-90


10-17-34 15-22-38 19-28-44 23-34-47 26-37-50 30-39-54 36-44-61 38-48-67 42-52-72
7-11-21 9-14-24 12-17-27 14-21-29 16-23-32 19-24-34 22-27-38 24-30-42 26-32-45
625

830

1040

1250

1460

1660

2080

2500

2910

14

19

24

28

34

40

45

14-23-45 20-30-52 26-38-58 30-44-63 35-49-68 40-53-73 48-59-82 52-64-90 56-69-97


11-18-36 16-24-42 21-30-46 24-35-50 28-39-54 32-42-58 38-47-66 42-51-72 45-55-78
7-11-23 10-15-26 13-19-29 15-22-32 17-25-34 20-36-37 24-29-41 26-32-45 28-35-48
735

980

1220

1470

1720

1960

2450

15

20

25

29

35

3940
41

3430
46

15-25-49 22-33-57 27-40-62 32-48-68 38-54-74 43-57-80 52-64-89 57-70-97 61-76-106


12-20-39 18-26-46 22-32-50 26-38-54 30-43-59 34-46-64 42-51-71 46-56-78 49-61-85
7-12-24 11-16-28 14-20-31 16-24-34 19-27-37 22-28-40 26-32-45 28-35-49 32-38-53

Performance notes apprear at end of table.

NC 50

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

Specialized Grilles

PERFORMANCE DATA

NC 20
Core Vel.
300
Core Nom.
Vel. Press.
0.006
Area, Duct
0 0.010
sq. Size,
22 0.011
Total
ft.
in.
Pres.
45 0.016

400
0.010
0.017
0.019
0.029

500
0.016
0.028
0.031
0.047

600
0.022
0.038
0.043
0.064

700
0.030
0.052
0.058
0.088

NC 30

NC 40

800
0.040
0.069
0.078
0.117

1000
0.062
0.107
0.120
0.181

1200
0.090
0.156
0.175
0.263

1400
0.122
0.211
0.237
0.356

2780

3340

3890

36

42

47

cfm
835
1110
1390
1670
1950
2220
36x12
NC

16
21
26
30
30x14
0 16-26-52 23-34-60 29-42-67 35-50-73 40-57-79 45-61-85
2.78 26x16
24x18 Throw, ft. 22 13-21-42 18-27-48 23-34-54 28-40-58 32-46-63 36-49-68
22x20
45 8-13-26 12-17-30 14-21-33 17-25-37 20-28-40 23-30-42

3.61

55-68-95

60-75-104 65-81-112

44-54-76
28-34-47

48-60-83
30-37-52

52-65-90
33-40-56

4330

5050

43

48

cfm 1080
1440
1800
2170
2530
3610
2890
72x8
60x10
NC

10
17
22
27
31
37
48x12
36x16
0 18-29-59 26-38-68 32-47-76 38-56-84 44-65-90 51-69-97 63-78-108
30x18
28x20 Throw, ft. 22 14-23-47 21-30-54 26-38-61 30-45-67 35-52-72 41-55-78 50-62-86
24x24
45 9-14-29 13-19-34 16-23-38 19-28-42 22-32-45 25-35-48 31-39-54
cfm

1290

1720

2140

2570

3000

3430

NC 50

69-86-118 75-93-128
55-69-94
35-43-59

60-74-102
38-46-64

4290

5150

6010

34-43-59

38-47-65

41-51-70

4650

5580

6510

48x14
NC

11
18
23
28
32
38
44
49
36x18
0 19-31-64 28-41-74 35-50-83 42-60-91 49-71-98 56-76-106 69-85-118 76-93-130 82-102-140
4.29
32x20
Throw, ft. 22 15-25-51 22-33-59 28-40-66 34-48-73 39-57-78 45-61-85 55-68-94 61-74-104 66-82-112
28x24
45 10-15-32 14-20-37 17-25-42 21-30-46 24-35-49 28-38-53

cfm

1400

1860

2320

2790

3260

3720

NC

11
18
23
28
32
38
44
49
48x16
0 20-33-67 29-43-78 36-54-87 44-65-95 51-74-103 58-79-110 72-89-123 79-97-135 86-105-146
4.65 36x20
30x24 Throw, ft. 22 16-26-54 23-34-62 29-43-70 32-52-76 41-59-82 49-63-88 58-71-98 63-78-108 69-84-117
45 10-16-33 15-22-39 18-27-43 22-32-48 25-37-52 29-40-55

5.58 36x24

36-44-61

39-49-67

43-52-73

cfm

1670

2230

2790

3350

3910

4460

5580

6700

7810

NC

12

19

24

29

33

39

45

50

0 22-36-73 31-47-85 40-59-95 47-72-104 55-81-113 63-87-122 79-97-135 87-107-148 93-116-160


Throw, ft. 22 18-29-58 25-38-68 32-47-76 38-58-83 44-65-90 50-70-98 63-78-108
45 11-18-37 16-23-43 20-30-48 23-36-52 28-41-57 31-44-61 39-49-67

6.25 30x30

www.titus-hvac.com | www.titus-energysolutions.com

JFA SUPPLY

70-86-118 74-93-130
43-53-74 47-53-80

cfm

1880

2500

3120

3750

4380

5000

6250

7500

NC

13

20

25

30

34

40

46

8750
51

0 23-37-78 33-49-90 42-62-100 50-75-103 58-86-119 67-93-128 84-104-143 92-113-156 98-123-169


Throw, ft. 22 18-30-62 26-39-72 34-50-80 40-60-82 46-69-95 54-74-102 67-83-114
45 12-19-39 17-25-45 21-31-50 25-37-51 29-43-60 34-46-64 42-52-72

PERFORMANCE NOTES

78-98-135
49-61-85

Each NC value represents the noise criterion curve


that will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7. Each NC
value is based on a room absorption of 10 dB, re
10-12 watts. Each NC value is further based on a
single grille operating at a 0 deflection setting. For
deflection settings of 22 or 45, increase the
stated sound levels by 1 and 7 NC, respectively.
Dash () in space indicates NC value less than 10.

VARIABLE AIR VOLUME APPLICATIONS

All Titus supply grilles can be applied to variable air


volume systems with excellent results. For detailed
selection methods, consult your Titus representative,
or the Engineering Guidelines section of this catalog.

PERFORMANCE DATA

Data obtained from tests conducted in accordance


with ANSI/ASHRAE Standard 70-2006.
All pressures are in inches of water.
Core velocities are in feet per minute.
Throw values are given for isothermal terminal velocities
of 150, 100 and 50 fpm. See the section, Engineering
Guidelines, in this catalog for throw information.
Dividing lines denote ranges of NC values.
The stated deflection settings refer to the blade
position. For a 20 upward deflection, use the
throw rating for the 0 setting and the total
pressure for the 22 horizontal setting.

74-90-125
46-57-78

I55

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

COMMERCIAL / INDUSTRIAL LOUVERED SUPPLY


GRILLES
POLE OPERATED
Available Model:
JFA
Supply grilles shall be Titus Model JFA of the sizes and
mounting types shown on the plans and outlet schedule.
The deflection blades shall be available parallel to the long
or short dimension of the grille. Construction shall include a
steel border having a minimum thickness of 18 gauge. Outer
borders shall be 1-inch wide and shall be assembled with
full penetration resistance welds at all four corners with a
reinforcing patch for extra strength. Screw holes shall be
countersunk for a neat appearance.
Front blades shall be constructed of heavy duty aluminum
and shall be contoured to a specifically designed airfoil
cross-section to meet published performance data. Front
blades shall be spaced inch apart and shall be mounted

Width

Border Type

Steel

XXXX

Surface Mount

Parallel to Long
Dimension

Parallel to Short
Dimension

X
Height

1
White (std.)
Aluminum

Blade Orientation

SPECIFICATIONS

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel or aluminum. Damper must be
operable from the face of the grille.
The grille finish shall be #26 white. The finish shall be an
anodic acrylic paint, baked at 315 F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Model
JFA

I56

in friction pivots on both ends for individual adjustment


without loosening or rattling. Blades shall extend completely
through the frame on the back side to ensure stability
throughout the complete cfm operating range of the grille.
Rear blades shall be spaced 1-inch on center and shall be
ganged and accessible for adjustment using a pole operator.

Optional Damper
Steel
AG-35
Aluminum AG-35-AA
XX
26
01
Finish

XX-XX-XX

Specialized Grilles

Drum Louver

Available Models:
DL
Products Include:
Standard Finish - #26 White.
Available Border Type
#1 - Surface Mount.
Titus Model DL drum louvers are
especially useful where long throws
are required. This requirement
occurs in installations where the
conditioned space is large, making
it impractical to bring the ductwork
close to the occupants. Examples
of such installations are shopping
malls, coliseums, field houses, air
terminals, factories and warehouses.

DL

Length of throw, plus horizontal


and vertical direction, can be
adjusted by means of the rotating
drum and pivoted blades.
Felt seal between the drum
and border stops leakage
and holds the drum securely
in the position selected.
Optional opposed-blade damper
with a screwdriver operator
accessible through the discharge
opening of the drum louver.

HIGH CAPACITY - LONG THROW

Material is aluminum frame


with aluminum drum.

Drum Louver
Hole on
Horizontal
Center Line,
6 x Sizes
Only

3/16"

Face
Seal
Ends
Only

Dia.

C
D

Drum
Rotation

With
Without
Damper Damper

6
10
12
15

28
30
25
27

30
30
25
27

2"

1111/16
1411/16
2011/16
2611/16
3211/16
3811/16
5011/16
6211/16
2211/16
2711/16
3211/16
3711/16
4211/16
5211/16
6211/16
7211/16
2211/16
3211/16
4211/16
5211/16
6211/16
7211/16
1711/16
2211/16
2711/16
3211/16
4211/16
5211/16
6211/16
7211/16

83/16
83/16
83/16
83/16
83/16
83/16
83/16
83/16
1115/16
1115/16
1115/16
1115/16
1115/16
1115/16
1115/16
1115/16
1315/16
1315/16
1315/16
1315/16
1315/16
1315/16
17
17
17
17
17
17
17
17

3
3
3
3
3
3
3
3
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

33/8
33/8
33/8
33/8
33/8
33/8
33/8
33/8
53/8
53/8
53/8
53/8
53/8
53/8
53/8
53/8
63/8
63/8
63/8
63/8
63/8
63/8
913/16
913/16
913/16
913/16
913/16
913/16
913/16
913/16

6
6
6
6
6
6
6
6
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
9

121/32
121/32
121/32
121/32
121/32
121/32
121/32
121/32
217/16
217/16
217/16
217/16
217/16
217/16
217/16
217/16
3
3
3
3
3
3
313/16
313/16
313/16
313/16
313/16
313/16
313/16
313/16

35/8
35/8
35/8
35/8
35/8
35/8
35/8
35/8
6
6
6
6
6
6
6
6
6
6
6
6
6
6
81/8
81/8
81/8
81/8
81/8
81/8
81/8
81/8

All dimensions are in inches.

Number
or Vanes

2
3
5
7
9
11
15
19
3
4
5
6
7
9
11
13
3
5
7
9
11
13
2
3
4
5
7
9
11
13

M
227/32
411/32
411/32
411/32
411/32
411/32
411/32
411/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32

Number
of Screw
Holes

8
8
8
10
12
14
18
22
10
12
14
16
18
22
26
30
9
14
18
22
26
30
8
10
12
14
18
22
26
30

DL

Maximum
Rotation
(degrees) Above
Duct
and Below
Size Horizontal Center
Line

95/8 x 67/16
125/8 x 67/16
185/8 x 67/16
245/8 x 67/16
305/8 x 67/16
365/8 x 67/16
485/8 x 67/16
605/8 x 67/16
205/8 x 103/16
255/8 x 103/16
305/8 x 103/16
355/8 x 103/16
405/8 x 103/16
505/8 x 103/16
605/8 x 103/16
705/8 x 103/16
205/8 x 123/16
305/8 x 123/16
405/8 x 123/16
505/8 x 123/16
605/8 x 123/16
705/8 x 123/16
155/8 x 153/16
205/8 x 153/16
255/8 x 153/16
305/8 x 153/16
405/8 x 153/16
505/8 x 153/16
605/8 x 153/16
705/8 x 153/16

A minus 2"

9x6
12 x 6
18 x 6
24 x 6
30 x 6
36 x 6
48 x 6
60 x 6
20 x 10
25 x 10
30 x 10
35 x 10
40 x 10
50 x 10
60 x 10
70 x 10
20 x 12
30 x 12
40 x 12
50 x 12
60 x 12
70 x 12
15 x 15
20 x 15
25 x 15
30 x 15
40 x 15
50 x 15
60 x 15
70 x 15

Airflow

Optional
Damper

"

Listed Size Duct Size Inches


Inches

Duct
Size

"

1"

Note: Model DL
drum louver can be
operated at high
discharge velocities.
However, if at these
velocities the static
pressure across the
drum louver itself is
more than 0.25 wg,
the optional opposedblade damper
becomes ineffective
and is therefore not
recommended.

www.titus-hvac.com | www.titus-energysolutions.com

DL

I57

Specialized Grilles

DL-SV
Length of throw, plus horizontal
and vertical direction, can be
adjusted by means of the rotating
drum and pivoted blades.
Felt seal between the drum
and border stops leakage
and holds the drum securely
in the position selected.
Optional opposed-blade damper
with a screwdriver operator
accessible through the discharge
opening of the drum louver.

HIGH CAPACITY - LONG THROW


Available Models:

DL-SV

Split Vane

Products Include:
Standard Finish - #26 White.
Available Border Type
#1 - Surface Mount.
DLSV drum grilles employ a split vane
design to produce diverging air streams
Titus Model DLSV drum louvers are
especially useful where long throws
are required. This requirement
occurs in installations where the
conditioned space is large, making
it impractical to bring the ductwork
close to the occupants. Examples
of such installations are shopping
malls, coliseums, field houses, air
terminals, factories and warehouses.

DL-SV

www.titus-hvac.com | www.titus-energysolutions.com

Drum Louver (continued)

Material is aluminum frame


with aluminum drum.

Drum Louver with Split Vane Option


Hole on
Horizontal
Center Line,
6 x Sizes
Only

Face
Seal
Ends
Only

Vane
Divider

3/16" Dia.

C
H

Duct
Size

Drum
Rotation

Air
Flow

L
1/2"
1 1/4"

Optional Damper
3/8"
E

J
A minus 2 1/2"
A

DL-SV

Note: Model DLSV


drum louver can be
operated at high
discharge velocities.
However, if at these
velocities the static
pressure across the
drum louver itself is
more than 0.25 wg,
the optional opposedblade damper
becomes ineffective
and is therefore not
recommended.

I58

Maximum
Rotation
(degrees) Above
Duct
and Below
Size Horizontal Center
Line
With
Without
Damper Damper

6
10
12
15

28
30
25
27

30
30
25
27

Listed Size Duct Size Inches


Inches

9x6
12 x 6
18 x 6
24 x 6
30 x 6
36 x 6
48 x 6
60 x 6
20 x 10
25 x 10
30 x 10
35 x 10
40 x 10
50 x 10
60 x 10
70 x 10
20 x 12
30 x 12
40 x 12
50 x 12
60 x 12
70 x 12
15 x 15
20 x 15
25 x 15
30 x 15
40 x 15
50 x 15
60 x 15
70 x 15

95/8 x 67/16
125/8 x 67/16
185/8 x 67/16
245/8 x 67/16
305/8 x 67/16
365/8 x 67/16
485/8 x 67/16
605/8 x 67/16
205/8 x 103/16
255/8 x 103/16
305/8 x 103/16
355/8 x 103/16
405/8 x 103/16
505/8 x 103/16
605/8 x 103/16
705/8 x 103/16
205/8 x 123/16
305/8 x 123/16
405/8 x 123/16
505/8 x 123/16
605/8 x 123/16
705/8 x 123/16
155/8 x 153/16
205/8 x 153/16
255/8 x 153/16
305/8 x 153/16
405/8 x 153/16
505/8 x 153/16
605/8 x 153/16
705/8 x 153/16

2 5/8"

1111/16
1411/16
2011/16
2611/16
3211/16
3811/16
5011/16
6211/16
2211/16
2711/16
3211/16
3711/16
4211/16
5211/16
6211/16
7211/16
2211/16
3211/16
4211/16
5211/16
6211/16
7211/16
1711/16
2211/16
2711/16
3211/16
4211/16
5211/16
6211/16
7211/16

83/16
83/16
83/16
83/16
83/16
83/16
83/16
83/16
1115/16
1115/16
1115/16
1115/16
1115/16
1115/16
1115/16
1115/16
1315/16
1315/16
1315/16
1315/16
1315/16
1315/16
17
17
17
17
17
17
17
17

3
3
3
3
3
3
3
3
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

33/8
33/8
33/8
33/8
33/8
33/8
33/8
33/8
53/8
53/8
53/8
53/8
53/8
53/8
53/8
53/8
63/8
63/8
63/8
63/8
63/8
63/8
913/16
913/16
913/16
913/16
913/16
913/16
913/16
913/16

6
6
6
6
6
6
6
6
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
9

121/32
121/32
121/32
121/32
121/32
121/32
121/32
121/32
217/16
217/16
217/16
217/16
217/16
217/16
217/16
217/16
3
3
3
3
3
3
313/16
313/16
313/16
313/16
313/16
313/16
313/16
313/16

35/8
35/8
35/8
35/8
35/8
35/8
35/8
35/8
6
6
6
6
6
6
6
6
6
6
6
6
6
6
81/8
81/8
81/8
81/8
81/8
81/8
81/8
81/8

All dimensions are in inches.

Number
or Vanes

2
3
5
7
9
11
15
19
3
4
5
6
7
9
11
13
3
5
7
9
11
13
2
3
4
5
7
9
11
13

M
227/32
411/32
411/32
411/32
411/32
411/32
411/32
411/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32
611/32

Number
of Screw
Holes

8
8
8
10
12
14
18
22
10
12
14
16
18
22
26
30
9
14
18
22
26
30
8
10
12
14
18
22
26
30

Specialized Grilles

PERFORMANCE DATA

Min. Duct
Area
sq. ft.

Listed
Size,
Inches

0.43

9X6

0.83

18X6

1.37

30X6

2.71

60X6

1.46

20X10

3.58

50X10

5.00

70X10

1.75

20X12

3.44

40X12

5.98

70X12

1.65

15X15

5.34

50X15

7.45

70X15

NC 20
300
0.006
129
<10
0.05
5-6-16
250
<10
0.05
11-16-28
411
<10
0.05
17-26-37
813
<10
0.05
30-36-51
438
<10
0.03
18-27-38
1074
<10
0.03
34-42-59
1499
<10
0.03
40-49-70
524
<10
0.03
22-29-41
1031
<10
0.03
33-41-58
1793
<10
0.03
44-54-76
494
<10
0.02
19-28-40
1602
<10
0.02
42-51-72
2235
10
0.02
49-60-85

NC 40

400
500
600
700
800
900
1000
0.010
0.016
0.022
0.031
0.040
0.050
0.062
172
215
258
301
344
387
430
<10
17
23
29
34
38
42
0.08
0.13
0.18
0.25
0.32
0.41
0.51
7-11-22
9-14-26
11-16-29 13-19-31 15-22-33
16-25-35
18-26-37
333
416
500
666
749
833
583
11
19
25
31
35
40
43
0.08
0.13
0.18
0.25
0.32
0.41
0.51
14-21-33 18-26-37 21-28-40 25-31-43 27-33-46
28-35-49
30-37-52
548
685
821
1095
1232
1369
958
10
18
24
29
34
38
42
0.13
0.18
0.25
0.32
0.41
0.51
0.08
37-45-63
23-30-42 27-33-47 30-37-52 32-39-56 34-42-60
38-47-67
1084
2710
1355
1626
1897
2168
2439
16
23
30
35
40
44
48
0.08
0.13
0.18
0.25
0.32
0.41
0.51
34-42-59 38-47-66 42-51-73 45-55-78 48-59-84
51-63-89
54-66-94
584
730
1021
1167
1313
1459
875
13
20
26
31
36
40
44
0.05
0.09
0.12
0.17
0.22
0.28
0.34
25-31-44 28-34-49 31-38-53 33-41-58 36-44-62
38-46-65
40-49-69
1433
1791
2149
2507
2865
3223
3582
16
23
29
35
40
44
48
0.05
0.09
0.12
0.17
0.22
0.28
0.34
39-48-68 44-54-76 48-59-84 52-64-90 56-68-96 59-72-102 62-76-108
1999
2498
3498
3997
4497
4996
2998
18
25
31
36
41
45
49
0.05
0.09
0.12
0.17
0.22
0.28
0.34
47-57-81 52-64-90 57-70-99 62-75-107 66-81-114 70-85-121 74-90-127
698
873
1222
1571
1746
1047
1396
13
20
27
32
37
41
45
0.05
0.08
0.11
0.16
0.20
0.26
0.32
27-34-48 31-38-53 34-41-58 36-45-63 39-48-67
41-50-71
43-53-75
1375
1719
2063
2407
2751
3094
3438
16
23
29
35
39
44
47
0.05
0.08
0.11
0.16
0.20
0.26
0.32
39-47-67 43-53-75 47-58-82 51-62-88 55-67-94 58-71-100 61-75-106
2391
2989
4184
5380
3586
4782
5977
26
32
37
42
46
50
19
0.05
0.08
0.11
0.16
0.20
0.26
0.32
51-62-88 57-70-98 62-76-108 67-82-117 72-88-125 76-93-132 80-98-139
659
824
1154
1483
989
1318
1648
13
20
27
32
37
41
45
0.04
0.07
0.10
0.13
0.17
0.22
0.27
25-33-46 30-37-52 33-40-57 35-43-61 38-46-65
40-49-69
42-52-73
2136
2670
3738
4805
5339
3204
4271
18
25
31
36
41
45
49
0.04
0.07
0.10
0.13
0.17
0.22
0.27
48-59-83 54-66-93 59-72-102 64-78-110 68-83-118 72-88-125 76-93-132
2979
3724
4469
5214
5959
6704
7449
19
27
32
38
43
47
51
0.17
0.22
0.27
0.04
0.07
0.10
0.13
57-70-98 63-78-110 70-85-120 75-92-130 80-98-139 85-104-148 90-110-155
NC 50

All data is based on tests


conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
Throw is based on isothermal air,
150, 100 and 50 fpm terminal
velocities. See the section,
Engineering Guidelines, in this
catalog for throw information.
Velocity Pressures are based
on nominal duct velocity.
Listed size is slightly less than
the minimum allowed duct
dimensions. (see pages I57-I58
for actual duct dimension)

Each NC value represents the


noise criterion that will not be
exceeded by the sound pressure
in any of the octave bands, 2nd
through 7th. Each NC value is
based on a room absorption
of 10dB, re 10-12 watts.
Throw is based on a 15
upward deflection. For 0
upward deflection multiply
throw values shown by 1.2. For
30 upward deflection multiply
throw values shown by 0.8.

Variable Air Volume Applications


Deflection

Throw

Total
Pressure

NC

0B

1.2

0.8

-4

30B

0.8

1.43

+4

All Titus supply grilles can be


applied to variable air volume
systems with excellent results.
For detailed selection methods,
consult your Titus representative
or the Engineering Guidelines
section of this catalog.

PERFORMANCE DATA

Duct Velocity
fpm
Vel. Press, in wg.
cfm
NC (Noise Criteria)
Total Press., in. wg
Throw, ft.
cfm
NC (Noise Criteria)
Total Press., in. wg
Throw
cfm
NC (Noise Criteria)
Total Press., in. wg
Throw, ft.
cfm
NC (Noise Criteria)
Total Press., in. wg
Throw, ft.
cfm
NC (Noise Criteria)
Total Press.
Throw
cfm
NC (Noise Criteria)
Total Press., in. wg
Throw, ft.
cfm
NC (Noise Criteria)
Total Press., in. wg
Throw, ft.
cfm
NC (Noise Criteria)
Total Press.
Throw
cfm
NC (Noise Criteria)
Total Press.
Throw
cfm
NC (Noise Criteria)
Total Press., in. wg
Throw, ft.
cfm
NC (Noise Criteria)
Total Press.
Throw, ft.
cfm
NC (Noise Criteria)
Total Press.
Throw
cfm
NC (Noise Criteria)
Total Press., in. wg
Throw, ft.

NC 30

www.titus-hvac.com | www.titus-energysolutions.com

DL DL-SV 15B UP

I59

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

DRUM LOUVER

blades shall be individually adjustable.

HIGH CAPACITY - LONG THROW

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel. Damper must be operable from the
face of the grille.

Available Models:
DL
DL-SV
Supply grilles shall be Titus Model DL for the sizes and
mounting type as shown on the plans and outlet schedule.
Outer borders shall be 1 inches wide and shall be
constructed of heavy gauge extruded aluminum. Corners
shall be assembled with full penetration resistance welds
with a reinforcing steel patch for extra strength.
Screw holes shall be countersunk for a neat appearance.
Drum shall be constructed of heavy gauge extruded
aluminum and shall rotate a minimum of 25 up and down
from center line of the diffuser. Heavy extruded aluminum

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Model
DL
DL-SV

Height
Single Vane DL

Optional Damper
AG-15-HD

Steel Heavy Duty

Split Vane DL-SV

XXXX
Width

XX-XX-XX

XX

Surface Mount

White (std.)

Border Type

Mill

SPECIFICATIONS

Aluminum

I60

26
04
01
Finish

Specialized Grilles

Drum Louver (continued)

HIGH CAPACITY - LONG THROW


Single Vane Universal End Cap
Split Vane Universal End Cap

US-DL

Available Models:

US-DL

US-DL-SV

Products Include:
Material: Aluminum extruded border and blades.
Standard Fnish - #26 White or #34 Clear Anodize.
Universal end cap design to fit multiple spiral duct diameters.
Foam gaskets for tight seal to spiral duct.

Length of throw, plus horizontal and vertical


direction, can be adjusted by means of the
rotating drum and pivoted adjustable blades.
Felt seal between the drum and border
frame prevents leakage and holds the drum
securely in the position selected.
Air scoop damper (ASD) or heavy duty opposed
blade damper (AG-50-HD) available as options.
AG-50-HD has screwdriver operator accessible
through discharge opening of the drum louver.

Models US-DL and US-DL-SV mount directly to


spiral duct eliminating the need for duct taps
and reducing installation costs and time.
US-DL-SV drum louvers employ a split vane
design to produce diverging air streams.
Great for applications requiring high
air volumes or long throws.
Vane Divider
(US-DL-SV only)

Sealing Gasket

Listed Size
+ 3 3/4

www.titus-hvac.com | www.titus-energysolutions.com

US-DL

Listed Size
+1

Directional Vanes
(Individually adjustable)

Available Sizes:
Width: 6, 10, 12, 15
Length: 6 through 48 in 1 increments
(fractional sizes are not available)

Listed Size + 3 1/4


Listed Size1

Listed Size

10

12

15

12 / 65

24 / 97

24 / 112

36 / 145

US-DL

Diffuser with
Spiral Duct Diameter
(Min/Max)

I61

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA
US-DL US-DL-SV DRUM AT 0B DEFLECTION AND NO SPREAD
6 HEIGHT
Size
12 x 6
18 x 6
24 x 6
36 x 6

Neck Velocity (fpm)


300
400
Velocity Pressure
0.006
0.010
Total Pressure
0.050
0.080
Airflow, cfm
160
215
NC (Noise Criteria)
12
Throw
7-10-19 9-14-22
Airflow, cfm
240
325
NC (Noise Criteria)
14
Throw
9-13-24 12-17-26
Airflow, cfm
325
430
NC (Noise Criteria)
17
Throw
10-15-28 13-20-32
Airflow, cfm
485
650
NC (Noise Criteria)
10
18
Throw
12-19-34 16-24-37

500
0.016
0.130
270
19
12-18-25
405
21
14-22-30
540
23
17-25-35
810
24
21-30-42

600
0.022
0.160
325
25
14-19-28
485
27
17-24-33
650
29
20-28-39
970
30
24-34-47

700
0.031
0.250
380
30
17-21-30
565
32
21-26-36
755
34
23-30-42
1135
35
29-37-51

800
0.040
0.320
430
33
18-22-32
650
35
23-28-38
865
37
26-32-45
1295
38
34-40-53

900
0.050
0.410
485
37
19-24-34
730
39
25-30-40
972
41
27-34-48
1460
42
35-42-56

1000
0.062
0.510
540
40
20-25-35
810
42
26-32-44
1040
44
28-35-49
1620
45
37-46-62

Neck Velocity (fpm)


Velocity Pressure
Total Pressure
Airflow, cfm
NC (Noise Criteria)
Throw
Airflow, cfm
NC (Noise Criteria)
Throw
Airflow, cfm
NC (Noise Criteria)
Throw
Airflow, cfm
NC (Noise Criteria)
Throw

300
0.006
0.030
525
10
12-18-34
657
11
14-21-40
790
13
15-23-44
1060
14
17-26-50

400
0.010
0.050
700
18
18-28-40
876
20
19-28-43
1050
21
21-31-47
1400
22
24-35-54

500
0.016
0.090
875
25
21-33-44
1095
26
24-35-49
1315
28
26-39-53
1750
29
30-45-62

600
0.022
0.120
1050
30
28-37-49
1314
31
28-40-55
1580
33
31-44-60
2100
34
35-50-69

700
0.031
0.170
1225
34
31-39-53
1535
36
34-43-59
1840
38
37-47-65
2450
39
43-54-75

800
0.040
0.220
1400
39
35-41-56
1750
41
39-46-62
2105
41
42-50-68
2800
42
49-58-78

900
0.050
0.280
1575
42
37-43-60
1970
44
41-48-65
2365
45
45-53-71
3150
46
52-60-82

1000
0.062
0.340
1750
46
39-48-65
2190
47
43-53-72
2630
48
47-58-79
3500
49
54-67-92

Neck Velocity (fpm)


Velocity Pressure
Total Pressure
Airflow, cfm
NC (Noise Criteria)
Throw
Airflow, cfm
NC (Noise Criteria)
Throw
Airflow, cfm
NC (Noise Criteria)
Throw
Airflow, cfm
NC (Noise Criteria)
Throw

300
0.006
0.030
470
12-18-34
625
12
14-20-39
940
13
17-25-47
1250
14
18-28-55

400
0.010
0.050
625
18
16-24-36
830
19
19-27-42
1250
21
23-33-51
1665
22
26-39-59

500
0.016
0.090
780
26
20-30-41
1040
27
23-34-48
1560
28
29-42-58
2080
29
33-49-65

600
0.022
0.120
935
31
24-34-46
1250
32
27-39-53
1875
33
33-47-65
2495
34
39-55-75

700
0.031
0.170
1090
35
29-37-50
1455
36
33-42-58
2185
38
40-49-70
2910
39
47-59-82

800
0.040
0.220
1250
40
33-39-52
1665
40
37-45-61
2500
42
46-54-74
3330
43
53-63-86

900
0.050
0.280
1400
43
35-41-55
1870
44
40-48-64
2810
45
48-58-78
3745
47
56-67-90

1000
0.062
0.340
1560
46
37-45-61
2030
47
42-52-71
3125
48
51-63-86
4160
49
60-73-100

10 HEIGHT

Size
24 x 10
30 x 10
36 x 10
44 x 10

12 HEIGHT
Size

PERFORMANCE DATA

18 x 12

I62

24 x 12
36 x 12
48 x 12

Specialized Grilles

PERFORMANCE DATA

Size
24 x 15
30 x 15
36 x 15
48 x 15

Neck Velocity (fpm)


Velocity Pressure
Total Pressure
Airflow, cfm
NC (Noise Criteria)
Throw
Airflow, cfm
NC (Noise Criteria)
Throw
Airflow, cfm
NC (Noise Criteria)
Throw
Airflow, cfm
NC (Noise Criteria)
Throw

300
0.006
0.020
775
13
15-22-43
970
13
17-25-49
1160
15
19-27-53
1550
16
21-32-61

400
0.010
0.040
1030
21
21-30-46
1290
22
23-34-52
1550
23
25-37-57
2065
24
30-43-66

500
0.016
0.070
1290
27
26-38-53
1615
28
29-43-59
1935
29
32-47-65
2580
30
37-54-75

600
0.022
0.100
1550
32
30-43-59
1940
33
34-49-67
2320
34
37-53-72
3100
35
43-61-84

700
0.031
0.130
1805
37
37-46-64
2260
38
41-52-72
2710
39
45-57-79
3610
40
52-65-91

800
0.040
0.170
2065
41
42-50-67
2585
42
47-56-76
3100
43
51-61-83
4130
44
59-70-95

900
1000
0.050
0.062
0.220
0.270
2320
2580
44
47
44-53-71 46-58-79
2910
3230
45
49
49-60-83 52-65-88
3485
3870
47
50
54-65-86 57-71-96
4645
5160
48
51
63-75-100 66-82-111

PERFORMANCE NOTES
Data obtained from tests conducted in accordance
with ANSI/ASHRAE Standard 70-2006.
Throw values are in feet at terminal velocities
of 150, 100 amd 50 fpm at isothermal
conditions. Throw values were measured with
drum at 0 deflection and no spread.
For an explanation of catalog throw data, see the
Engineering Guidelines section of this catalog.
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.

Each NC value represents the noise criteria curve


that will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.
Velocity pressure is based on inlet
duct area and velocity.
To obtain static pressure, subtract velocity
pressure from the total pressure.
Listed size is slightly less than the minimum
allowed duct dimensions (refer to data
page for actual duct dimensions).

www.titus-hvac.com | www.titus-energysolutions.com

15 HEIGHT

PERFORMANCE DATA
I63

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

UNIVERSAL END CAP


Available Models:

US-DL

US-DL-SV

Single Vane
Split Vane

Aluminum supply grilles shall be Titus direct spiral duct


mounted supply grille models: US-DL (single vane) or USDL-SV (split vane) for the sizes and mounting type as shown
on the plans and out schedule. Frame and drum shall be
constructed of heavy gauge extruded aluminum. Drum shall
rotate a minimum of 25 up and down from center line of
the grille. Heavy duty extruded aluminum blades shall be
individually adjustable.

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION

Model
US-DL
US-DL-SV

Height

Mill (Std)
White

Single Vane DL

Aluminum

Finish
04
26
01

Split Vane DL

Width

SPECIFICATIONS

The grille finish shall be #34 clear anodized. Optional


finish shall be #26 white. The white paint finish shall be a
powdercoat paint, baked at 315 for 30 minutes. The pencil
hardness must be HB to H. The paint must pass a 100-hour
ASTM B117 Corrosive Environments Salt Spray Test without
creepage, blistering or deterioration of film. The paint must
pass a 250-hour ASTM D870 Water Immersion Test. The
paint must also pass the ASTM D2794 Reverse Impact
Cracking Test with a 50-inch pound force applied.

Optional air scoop damper/extractor (ASD) shall be


constructed of heavy gauge aluminum. The ASD must

XXXXXX

I64

be operable from grille face with a screwdriver. Optional


opposed blade damper (AG-50-AA-HD) shall be constructed
of heavy gauge extruded aluminum. Damper must be
operable from grille face.

SPIRAL DUCT DRUM LOUVER

XX

XX

XX

Surface Mount

Air scoop damper

Border Type

Aluminum heavy
duty damper

XXXXXX
ASD
AG-50-HD

Specialized Grilles

OPTIONS & ACCESSORIES


Type
Grille

Type
Deflection

Deflection
Degrees

50F

AL-Return

Eggcrate

N/A

50F

AL-Return

Eggcrate

N/A

50F

AL-Return

Eggcrate

N/A

50F

AL-Return

Eggcrate

N/A

50R-SS

304 SS-Return

Eggrate

N/A

50F-NT

AL-Return

Eggcrate

N/A

50FF
50FF

AL-Filter Return
AL-Filter Return

Eggcrate
Eggcrate

N/A
N/A

8R

Stl- Return

Perforated

N/A

8R

Stl- Return

Perforated

N/A

8F

AL- Return

Perforated

N/A

8F

AL- Return

Perforated

N/A

8F

AL- Return

Perforated

N/A

8F

AL- Return

Perforated

N/A

Blade
Border
Spacing
Type
x x
X X 1
1
1 X 1 X 1
X X
X X 1
3
1 X 1 X 1
X X
X X 1
7
1 X 1 X 1
X X
X X 1
8
1 X 1 X 1
X X
1
X X
X X 1
NT
1 X 1 X 1
X X
1
X X
3
3
/16 Dia. Holes
1
On Centers
3
/16 Dia. Holes
3
On Centers
3
/16 Dia. Holes
1
On Centers
3
/16 Dia. Holes
2
On Centers
3
/16 Dia. Holes
3
On Centers
3
/16 Dia. Holes
4
On Centers
3
/16 Dia. Holes
1
On Centers
3
/16 Dia. Holes
1
On Centers
3
/16 Dia. Holes
3
On Centers
3
/16 Dia. Holes
1
On Centers
3
/16 Dia. Holes
3
On Centers
1

8SS*

304 SS-Return

Perforated

N/A

8RF

Stl- Filter Return

Perforated

N/A

8RF

Stl- Filter Return

Perforated

N/A

8FF

AL- Filter Return

Perforated

N/A

8FF

AL- Filter Return

Perforated

N/A

33RL
30RL

Single
Single

38
0

Single

38

Single

Single

30

60FL

HD Steel Return
HD Steel Return
HD Steel Filter
Return
HD Steel Filter
Return
HD Aluminum
Return
HD Aluminum
Return

Single

T-700

Stl - Door Grille

Single

CT-700

AL-Door Grille

Single

77

33RFL
30RFL
63FL

PFA

PFAP EQT

N
N

N
N

Y
Y

Y
Y

Y
Y

N
N

N
N

N
N

N
N

Y
N

N
N

N
N

N
N

N
Y

Y
Y

Y
Y

Y
Y

Y
Y

Y
Y

N
N

Y
Y

Y
Y

Y
Y

Y
Y

N
N

N
N

Y
Y

Y
Y

77

/16

Front, 1

Varies

DL

Drum Louver

Rear

Vertically Rotating
Drum with Blades for Adjustable
Horizontal Adjustment
Double

Adjustable

Single

Adjustable

Double

Adjustable

Single

Adjustable

Perforated

N/A

/16 Dia. Holes


On Centers

Single

Adjustable

* Note: 8SS only available with 04 and 26 finishes. Caution: All options are not available in all combinations. Check with your
Titus representative for details. Titus reserves the right to discontinue or add options at any time without notice.

OPTIONS & ACCESSORIES

Adjustable

US8F

PF

Double

S8F

FG

Stl-Supply-Gang
Operated Rear
Blades

Direct Spriral
Duct-Mounted w
Universal Border
Direct Spriral
Duct-Mounted
w Radius End
Caps
Direct Spriral
Duct-Mounted w
Universal Border

IS

JFA

US301

DS

Single

US300

AL-Supply
Reversible Core

S301

#01 #04

1700

S300

FR

5 up,
15 up,
5 down,
15 up

Direct Spriral
Duct-Mounted
w Radius End
Caps
Direct Spriral
Duct-Mounted
w Radius End
Caps
Direct Spriral
Duct-Mounted w
Universal Border

#20
#34 #94
#21 #26 #84 #95 #96

OS

www.titus-hvac.com | www.titus-energysolutions.com

Model
Number

I65

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

OPTIONS & ACCESSORIES

SERIES FINISHES, OPTIONS AND ACCESSORIES


Finishes:










#01
#04
#20
#21
#25
#26
#34
#84
#94
#95
#96

Aluminum Colored Paint


Mill Finish
Envirotherm Color To Match Sample*
Envirothane Color To Match Sample*
Off White*
White (standard on most models)
Clear Anodized*
Black*
Light Bronze Anodized*
Medium Bronze Anodized*
Dark Bronze Anodized*

Options And Accessories:


OS

FR

C

DS


IS


FG


PF

PFA

Oversize
Fractional Size
Concealed Fasteners
Debris Screen Square Mesh
Galvanized Steel Screen
Insect Screen 1/16 Square Mesh
Galvanized Steel Screen
Foam Gasket On Back Side of
Border
Steel Plaster Frame
Aluminum Plaster Frame



PF-SS

EQT

Stainless Steel Plaster Frame


Earthquake Tab For Safety Wiring
to Support Structure

Note: An asterisk (*) indicates additional cost.

BORDER TYPES

Snap-In

BORDER TYPE 2
SNAP-IN (PANEL MOUNTED)

Available Module Sizes

13/16"

24 x 24 inches

Ceiling Module Size


minus 1/16"
Note: Maximum grille area is module size minus 4 inches.
Lay-In (Panel Mounted)

BORDER TYPE 3
LAY-IN (PANEL MOUNTED)


Available Module Sizes
12 x 12 inches
24 x 12 inches
36 x 12 inches
48 x 12 inches
24 x 24 inches
36 x 24 inches
48 x 24 inches

Ceiling Module Size


minus "
Note: Maximum grille area is module size minus 4 inches.
Spline (Panel Mounted)

BORDER TYPE 4
SPLINE (PANEL MOUNTED)

Available Module Sizes

OPTIONS & ACCESSORIES

24 x 24 inches

I66

Note: Filter grilles not available in all


module sizes.

"
"
Ceiling Module Size
minus "
Note: Maximum grille area is module size minus 4 inches.

Channel Frame

BORDER TYPE 7 (MODEL 50F ONLY)


CHANNEL FRAME

Available Module Sizes

6 x 4 inches through 48 x 48
inches in 2-inch increments.

Ceiling Module Size


minus "

Note: Maximum grille size is 48 x 48 inches.

Specialized Grilles

OPTIONS & ACCESSORIES


Narrow Tee

NARROW TEE

Available Module Sizes


24 x 12 inches
24 x 24 inches

16 "
5

16 "

CEILING MODULE MINUS 3/4"

ACCESSORIES
TYPE A FASTENING - SURFACE
MOUNT

Standard For All Border Type


1 Surface Mount Grilles.
Note: For screw hole locations
see the chart, Screw Hole
Location Chart.

Type A External Screw

www.titus-hvac.com | www.titus-energysolutions.com

BORDER TYPE NT
NARROW TEE (PANEL MOUNTED)

Type C Concealed Screw


1" x " Angle Clip
(by others)
Existing Duct

#8 Screw
(by others)

Ceiling or Wall

TYPE C FASTENING CONCEALED


MOUNTING

1" x " Angle Clip


Attached to Grille
(by Titus)

Available on Most Models


with Border Type 1.

Flange or Grille

OPTIONS & ACCESSORIES


I67

Specialized Grilles

www.titus-hvac.com | www.titus-energysolutions.com

Universal Filter Frames


HINGE LOCATIONS

LONG BLADE (L)

SHORT BLADE

(S)

TOP HINGE

(T)

BOTTOM HINGE

(B)

(L)

LEFT HINGE

(L)

RIGHT HINGE (R)

RIGHT HINGE

(R)

TOP HINGE

(T)

BOTTOM HINGE (B)

1/4 TURN
FASTENER

UNIVERSAL FILTER FRAMES

KNURLED KNOB

I68

LEFT HINGE

ARROWS SHOW BLADE DEFLECTION

security products

J
www.titus-hvac.com | www.titus-energysolutions.com

www.titus-hvac.com | www.titus-energysolutions.com

Table of Contents

Security Products

security products
Security Products........................................................................................................................................................................... J4

overview
Overview......................................................................................................................................................................................... J6

maximum security
Suicide Deterrent............................................................................................................................................................................ J7
SG-SD...................................................................................................................................................................................... J7
Performance Data................................................................................................................................................................... J8
Suggested Specifications........................................................................................................................................................ J9
Model Number Specification.................................................................................................................................................. J9
Round Perforated.......................................................................................................................................................................... J10
SG-PR, SG-PRA, SG-PRT....................................................................................................................................................... J10
Performance Data................................................................................................................................................................. J11
Suggested Specifications...................................................................................................................................................... J12
Model Number Specification................................................................................................................................................ J12
Square Perforated......................................................................................................................................................................... J13
SG-PS.................................................................................................................................................................................... J13
Performance Data................................................................................................................................................................. J14
Suggested Specifications...................................................................................................................................................... J15
Model Number Specification................................................................................................................................................ J15

medium security
Steel Fixed Bars............................................................................................................................................................................ J16
SG-3300RL............................................................................................................................................................................ J16
Performance Data................................................................................................................................................................. J17
Suggested Specifications...................................................................................................................................................... J18
Model Number Specification................................................................................................................................................ J18

minimum security

SECURITY PRODUCTS

Aluminum Fixed Bars.................................................................................................................................................................... J19


SG-1500FL............................................................................................................................................................................. J19
Performance Data................................................................................................................................................................. J20
Suggested Specifications...................................................................................................................................................... J21
Model Number Specification................................................................................................................................................ J21

J2

Louvered Core, Lattice Face.......................................................................................................................................................... J22


SG-TDC.................................................................................................................................................................................. J22
Performance Data................................................................................................................................................................. J23
Suggested Specification....................................................................................................................................................... J24
Model Number Specification................................................................................................................................................ J24
Lattice Face, 13/16-inch Square Holes on 1-inch Centers............................................................................................................... J25
SG-LFO, SG-LFO-AA.............................................................................................................................................................. J25
Suggested Specifications...................................................................................................................................................... J26
Model Number Specification................................................................................................................................................ J26
Lattice Face with Plaster Frame, 13/16-inch Square Holes on 1-inch Centers................................................................................ J27
SG-LFF, SG-LFF-AA................................................................................................................................................................ J27
Suggested Specifications...................................................................................................................................................... J28
Model Number Specification................................................................................................................................................ J28

Table of Contents (continued)

Security Products

Barrier with Frame........................................................................................................................................................................ J29


SG-BG-FM............................................................................................................................................................................. J29
Suggested Specifications...................................................................................................................................................... J30
Model Number Specification................................................................................................................................................ J30
Barrier with Sleeve....................................................................................................................................................................... J31
SG-BG-SLV............................................................................................................................................................................ J31
Suggested Specifications...................................................................................................................................................... J32
Model Number Specification................................................................................................................................................ J32

options
Options......................................................................................................................................................................................... J33

Suggested Specifications............................................................................................................................................................. J33

www.titus-hvac.com | www.titus-energysolutions.com

barrier grilles

application suggestions

Application Suggestions............................................................................................................................................................... J34

installation methods

Typical Installation Methods........................................................................................................................................................ J35

pressure loss

Pressure Loss Through Perforated Plate Based on Free Area....................................................................................................... J36

SECURITY PRODUCTS
J3

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

Security Products

MAXIMUM SECURITY GRILLES

pages: J7-J15

SG-SD
SUICIDE DETERRENT

ROUND PERFORATED

SQUARE PERFORATED

The standard for suicide deterrent maximum


security grilles.

Allow greater airflow without compromising


security.
Stainless steel and aluminum models available
for kitchens, showers and other corrosive or
humid areas.
Transfer grille model available for secure air
transfer through wall.

The industry standard square perforated


maximum security grille.
10-gauge #2 mesh behind face is backed up by
an additional 3/16-inch steel plate.

Complies with
NIC Guidelines for
Suicide Prevention
and California Title
24

MEDIUM SECURITY GRILLES

SECURITY PRODUCTS

pages: J16-J18

J4

SG-PS

SG-PR / SG-PRA / SG-PRT

SG-3300RL
STEEL FIXED BAR
Exceptionally strong bar grille for sidewall applications.
Steel blades pierce frame and are individually welded to prevent removal.
Blades backed by heavy 3/8-inch woven steel mesh in place by welded angles.

Security Products

Security Products (continued)

SG-TDC

SG-1500FL

SG-LFO / SG-LFO-AA

SG-LFF / SG-LFF-AA

ALUMINUM FIXED BAR

LOUVERED CORE

LATTICE FACE

LATTICE FACE & FRAME

/8-inch extruded aluminum bars on


1
/2-inch centers.
0B deflection.
Ideal for showers and other humid
areas.

Designed for maximum performance


with security for supervised areas.
Available in 1-, 2-, 3-, 4-way
deflection.
12-gauge lattice face covers diffuser.
Available in stainless steel.

Use over standard grilles or duct


where additional security is needed.
Face has 13/16-inch square holes on
1-inch centers.
Available in steel, aluminum and
stainless steel.
Available in round hole pattern.

Use as supply or return grille for


minimum security areas.
Available with opposed-blade
damper.
Face has 13/16-inch square holes on
1-inch centers.
Available in steel, aluminum and
stainless steel.
Available in round hole pattern.

www.titus-hvac.com | www.titus-energysolutions.com

MINIMUM SECURITY GRILLES

pages: J19-J28

BARRIER GRILLES

pages: J29-J32

BARRIER & FRAME

BARRIER & SLEEVE

Easily slides into wall, duct or roof opening.


Has a 3/4-inch diameter vertical and horizontal bars with maximum 6-inch spacing.

Ideal barrier for wall, roof or duct penetration.


Has 3/4-inch diameter vertical bars on 6-inch centers.
21/2 x 1/4-inch flat bars on 6-inch centers.
21/2 x 1/4-inch frame.

SECURITY PRODUCTS

SG-BG-SLV

SG-BG-FM

J5

www.titus-hvac.com | www.titus-energysolutions.com

Overview

SECURITY PRODUCTS

J6

Titus offers a complete line of security grilles to


accommodate maximum, medium and minimum security
applications that require secure HVAC outlets. Titus security
grilles are designed to provide superior performance in
supply and return applications without compromising
security and safety. Security grilles feature heavy gauge
material with all welded construction and integral stitch
welded sleeves in lengths up to 18. Options include
opposed blade dampers, angle frames, anchor bars, and
sleeve barriers.





Can be used in supply or return applications


Constructed of heavy gauge steel or aluminum
3
/16 sleeve is stitch welded on all seams
Available with front or rear operated dampers
Optional angle frame, anchor bars, and sleeve barriers
Standard finish is British White

Security Products

Security Products
Sleeve:3/16-inch steel.

Available Model:

SG-SD

Standard Finish - #26 White.

Steel

SG-SD

SUICIDE DETERRENT

All welded construction.


The SG-SD is a maximum security grille.
The design of this grille allows a greater
effective free area and superior airflow
without compromising security and safety.
The SG-SD complies with National Institute of
Corrections guidelines for suicide prevention
and California Title 24.

STANDARD CONSTRUCTION
DETAILS

Face plate:3/16-inch steel with


3
/16-inch diameter holes on 9/32inch staggered centers and 1-inch
border.

Width plus 2"

Angle Frame - 1 x 1 x 3/16inch steel angle iron shipped


loose for field wielding. Frame is
mill finish.

Anchor Bars - -inch diameter


steel bars, 3 inches in height.
Positioned 3 inches from back of
face plate on top and bottom
of sleeve.

Sleeve Barrier Grille - constructed


of -inch diameter steel bars with
maximum 6-inch opening.
Finish - #04 Mill.

Rear Operated Damper - AG-15


steel opposed blade damper. Slot
operated from rear of the grille.

3/16"

Steel
Face Plate

Dia. Holes

Complies with
NIC Guidelines for
Suicide Prevention
and California Title
24

Optional Mounting
Angle Frame

3/16"

Height plus 2"

SG-SD

OPTIONS

www.titus-hvac.com | www.titus-energysolutions.com

Maximum Security
SG-SD

Height

Sleeve Length

3/16" Steel
Sleeve

Width
Notes:
1. For standard product, width and height should be
specified in even 1-inch increments.
Dimensions Available
6 to 30 inches
4 to 30 inches
4 to 18 inches in 1-inch increments

Disclaimer:
The SG-SD is designed to increase inmate safety through compliance with the most recent known industry guidelines and
design practices for products of its type. This is not meant to imply that the product cannot be used to inflict harm or is suicide
proof. Titus warrants only the construction and airflow performance of the product as cataloged.
All dimensions are in inches.

SG-SD

Width:
Height:
Sleeve Length:

2. Typical mounting is accomplished by using an angle


frame (11/2 x 11/2 x 3/16-inch) shipped loose for field
welding.

J7

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA
SG-SD
Neck Neck
Area
Size
Area Factor
(in) (Sq. ft)
Ak

6x6

8x8

0.250

0.444

10x10 0.694

12x12 1.000

18x18 2.250

24x24 4.000

PERFORMANCE DATA

30x30 6.250

J8

Neck Velocity, fpm


Velocity Pressure

100
0.001

150
0.001

200
0.003

250
0.004

0.088

Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT

25
225
0.005
1-2-8

38
338
0.012
2-4-13

50
451
0.022
3-8-17

63
564
0.034
5-11-21

75
88
100
113
125
676
789
902
1014
1127
0.049
0.066
0.086
0.109
0.135
11
14
18
8-13-23 10-15-25 11-17-27 13-19-28 14-21-30

0.164

Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT

44
212
0.005
1-2-9

67
318
0.011
2-5-16

89
424
0.020
4-9-22

111
530
0.031
7-14-27

133
155
178
200
222
636
742
848
953
1059
0.045
0.062
0.080
0.102
0.126
13
17
21
9-16-31 13-19-33 15-22-36 16-24-38 18-27-40

0.265

Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT

69
202
0.005
1-3-11

104
303
0.011
3-6-20

139
404
0.019
5-11-27

174
208
243
278
312
347
505
606
707
808
909
1009
0.030
0.043
0.058
0.076
0.096
0.119
11
16
20
23
8-17-33 11-20-39 15-23-42 18-27-45 20-30-47 22-33-50

0.392

Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT

100
194
0.005
1-3-12

150
291
0.010
3-7-23

200
388
0.018
6-12-31

250
300
350
400
450
500
485
582
679
776
873
970
0.028
0.041
0.055
0.072
0.092
0.113
13
18
22
25
9-19-39 12-23-46 17-27-50 21-31-53 23-35-57 26-39-60

0.936

Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT

225
178
0.004
2-4-16

338
267
0.009
4-9-34

450
563
675
788
900
1013
1125
356
445
533
622
711
800
889
0.016
0.026
0.037
0.050
0.065
0.083
0.102
12
17
22
26
29
7-16-45 11-25-56 16-34-67 22-39-75 29-45-80 34-51-85 37-56-90

1.736

Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT

400
167
0.004
2-5-20

600
251
0.009
5-11-44

800
1000
1200
1400
1600
1800
2000
334
418
501
585
668
752
836
0.015
0.024
0.034
0.046
0.061
0.077
0.095
15
20
25
29
32
9-20-58 14-31-73 20-44-87 27-51-100 35-58-107 44-65-113 48-73-120

2.804

Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT

625
159
0.004
3-6-23

938
1250
1563
1875
2188
2500
2813
3125
239
318
398
478
557
637
717
796
0.008
0.014
0.022
0.032
0.044
0.057
0.073
0.090
12
18
23
27
31
34
6-13-52 10-23-71 16-36-89 23-52-106 31-62-124 41-71-134 52-80-142 59-89-149

Data obtained from tests conducted in accordance


with ANSI/ASHRAE Standard 70-2006.
All data based upon supply performance.
All pressures are in inches of water.
The negative static pressure for return performance is
equal to the total pressure of supply at the same cfm.

300
0.006

350
0.008

400
0.010

450
0.013

500
0.016

Throw values are for terminal velocities of 150,


100 and 50 fpm under isothermal conditions.
See the section, Engineering Guidelines,
in this catalog for throw information.
Noise Criteria values are based on a
room absorption of 10 dB.
Dash (-) in space indicates NC value less than 10.
Return NC is 2 NC higher than
supply NC at the same cfm.

Security Products

SUGGESTED SPECIFICATIONS

Available Model:

SG-SD





Steel
Round Perforated
Suicide Deterrent

SG-SD STEEL ROUND PERFORATED FACE

Suicide-deterrent security grilles designed for maximum


security applications shall be Titus model SG-SD of the sizes
and mounting type shown on the plans and outlet schedule.
Grilles shall have a 3/16-inch thick steel face and shall comply
with the National Institute of Corrections guidelines for
suicide prevention. The sleeve shall be 3/16-inch thick and
shall be stitch-welded to the face and along the entire
length of all sleeve seams.

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film.
The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

www.titus-hvac.com | www.titus-energysolutions.com

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel or aluminum. Damper must be
operated from the rear of the grille.

MAXIMUM SECURITY SUICIDE DETERRENT

MODEL NUMBER SPECIFICATION


Sleeve Length
Model
Steel
SG-SD
Width

Damper Model
None
O
Rear Operated
DR
Steel Damper

4 to 18
in 1-inch
increments

Height

XX
None

Angle Frame
Shipped
loose for field
welding

O
AF

Angle Mounting

Sleeve Barrier Grille


None
Barrier Grille

AG-15

XX

XX

White (std.)
Mill

26
04
Finish

XX

XX

O
BG

XX-XX

O
AB
Anchor Bars

None
Anchor Bars

SPECIFICATIONS
J9

Security Products

SG-PR
ROUND PERFORATED
Available Models:

SG-PR

SG-PRA

SG-PRT

STANDARD CONSTRUCTION
DETAILS

Steel
Aluminum
Steel

The SG-PR is a maximum security grille. The


design of this grille allows a greater effective
free area and airflow without compromising
security and safety.
The Titus model SG-PRA is used in areas
where moisture may cause a problem with
standard steel grilles. The SG-PRT is provided
with two face plates welded to each end of a
sleeve for block walls or for pouring in place
in concrete walls.
Note: The SG-PR is also available
in stainless steel for corrosive
environments.

Face plate: 3/16-inch steel with


5
/16-inch diameter holes on
7
/16-inch staggered centers and
1-inch border.

SG-PR

www.titus-hvac.com | www.titus-energysolutions.com

Maximum Security (continued)

Sleeve: 3/16-inch steel.


Standard Finish - #26 White.
All welded construction.

OPTIONS

Angle Frame - 1 x 1 x 3/16-inch


steel angle iron shipped loose for
field welding. Frame is mill finish.

Anchor Bars - -inch diameter


steel bars, 3-inch height.
Positioned 3 inches from back of
face plate on top and bottom
of sleeve.

Face Operated Damper - AG-15


steel opposed-blade damper. Slot
operated from face of the grille.
Rear Operated Damper - AG-15
steel opposed blade damper. Slot
operated from rear of the grille.
Sleeve Barrier Grille - constructed
of -inch diameter steel bars with
maximum 6-inch opening.
Finish - #04 Mill.

SG-PR

Optional Mounting
Angle Frame

3/16"

Steel
Face Plate
Height plus 2"

Width plus 2"

5/16"

Dia. Holes

Height

Sleeve Length

3/16"

Steel
Sleeve

SG-PR

Width
Notes:
1. For standard product, width and height should be
specified in even 1-inch increments.
Dimensions Available
Width:
Height:
Sleeve Length:

J10

2. Typical mounting is accomplished by using an angle


frame (11/2 x 11/2 x 3/16-inch) shipped loose for field
welding.

6 to 30 inches
4 to 30 inches
4 to 18 inches in 1-inch increments

All dimensions are in inches.

Security Products

PERFORMANCE DATA

Neck Neck
Area
Size
Area Factor
(in) (sq. ft)
Ak
0.25

0.078

8x8

0.44

0.153

9x9

0.56

0.201

12x12

1.00

0.392

16x16

1.78

0.764

18x18

2.25

1.004

20x20

2.78

1.281

24x24

4.00

1.956

26x26

4.69

2.355

30x30

6.25

3.283

100
0.001
25
224
0.005
1-2-8
44
204
0.004
1-2-9
56
196
0.004
1-2-9
100
178
0.004
1-3-11
178
162
0.003
1-3-13
225
156
0.003
1-3-13
278
150
0.003
2-4-14
400
142
0.003
2-4-15
469
138
0.003
2-4-16
625
131
0.002
2-4-17

150
0.001
38
337
0.011
2-4-13
67
306
0.010
2-5-16
84
294
0.009
2-5-18
150
267
0.008
3-6-22
267
243
0.007
3-7-28
338
234
0.007
3-8-30
417
226
0.007
4-8-32
600
212
0.006
4-9-35
704
207
0.006
4-9-36
938
197
0.006
4-10-39

200
0.003
50
449
0.020
3-8-17
89
408
0.017
4-9-21
113
392
0.017
4-9-24
200
356
0.015
5-11-30
356
324
0.013
6-13-38
450
312
0.012
6-13-42
556
301
0.012
6-14-46
800
283
0.011
7-15-53
939
276
0.011
11
7-16-57
1250
263
0.010
16
8-17-64

Data obtained from tests conducted in accordance


with ANSI/ASHRAE Standard 70-2006.
All data based upon supply performance.
All pressures are in inches of water.
The negative static pressure for return performance is
equal to the total pressure of supply at the same cfm.

250
0.004
63
561
0.031
5-11-21
111
510
0.027
6-13-27
141
490
0.026
7-15-29
250
446
0.023
8-17-37
444
405
0.020
9-20-48
563
389
0.019
9-21-53
694
376
0.018
12
10-22-57
1000
354
0.017
18
11-24-67
1174
345
0.016
20
11-25-71
1563
329
0.015
24
12-27-80

300
0.006
75
673
0.044
8-13-25
133
612
0.039
9-16-32
169
588
0.037
9-18-35
300
535
0.033
11-22-45
533
486
0.029
12
13-28-57
675
467
0.028
16
13-30-63
833
451
0.026
19
14-32-69
1200
425
0.025
25
15-35-80
1408
414
0.024
27
16-36-86
1875
394
0.022
31
17-39-97

350
0.008
88
785
0.060
10-15-29
156
714
0.053
12-19-37
197
686
0.051
13-21-41
350
624
0.045
10
15-26-52
622
567
0.040
18
17-33-67
788
545
0.038
22
18-37-74
972
527
0.036
25
19-40-80
1400
496
0.033
31
21-47-94
1643
483
0.032
33
22-49-100
2188
460
0.030
37
24-53-113

400
0.010
100
897
0.079
11-17-34
178
816
0.070
14-21-43
225
784
0.066
16-24-47
400
713
0.059
15
19-30-60
711
648
0.052
24
22-38-76
900
623
0.049
27
24-42-84
1111
602
0.047
30
25-46-92
1600
566
0.044
36
27-53-107
1878
552
0.042
38
29-57-114
2500
526
0.040
43
31-64-129

450
0.013
113
1010
0.100
13-19-38
200
918
0.088
16-24-48
253
882
0.084
11
18-27-53
450
802
0.074
19
22-34-67
800
729
0.066
28
28-43-86
1013
701
0.062
32
30-47-95
1250
677
0.060
35
32-52-103
1800
637
0.055
40
35-60-120
2112
620
0.053
43
36-64-129
2813
592
0.050
47
39-72-145

500
0.016
125
1122
0.123
14-21-42
222
1020
0.109
11
18-27-53
281
981
0.104
15
20-29-59
500
891
0.092
23
25-37-75
889
810
0.081
32
32-48-95
1125
779
0.077
36
35-53-105
1389
752
0.074
39
38-57-115
2000
708
0.068
45
43-67-134
2347
689
0.066
47
45-71-143
3125
657
0.062
51
48-80-161

Throw values are for terminal velocities of 150,


100 and 50 fpm under isothermal conditions.
See the section Engineering Guidelines, in
this catalog for throw information.
Noise Criteria values are based on a
room absorption of 10 dB.
Dash (-) in space indicates NC value less than 10.
Return NC is 2 NC higher than
supply NC at the same cfm.

PERFORMANCE DATA

6x6

Neck Velocity, fpm


Velocity Pressure
Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT
Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT
Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT
Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT
Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT
Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT
Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT
Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT
Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT
Airflow, cfm
Face Velocity, fpm
Total Pressure
Noise Criteria
Throw, FT

www.titus-hvac.com | www.titus-energysolutions.com

SG-PR, SG-PRA

J11

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS
MAXIMUM SECURITY ROUND PERFORATED
Available Models:

SG-PR




SG-PRA




SG-PRT


SG-PRT STEEL TRANSFER GRILLE

Maximum security transfer grilles shall be Titus Model SGPRT of the sizes and mounting type shown on the plans
and outlet schedule. Maximum security transfer grilles shall
have two 3/16-inch thick steel faces interconnected by a
3
/16-inch thick steel sleeve. The faces of the grille shall have
5
/16-inch diameter holes on 7/16-inch staggered centers. The
sleeve shall be 3/16-inch thick and shall be stitch welded to
the faces and along the entire length of all sleeve seams.

Steel
Round Perforated
Aluminum
Round Perforated
Steel
Transfer Grille

SG-PR STEEL ROUND PERFORATED FACE

Maximum security grilles shall be Titus Model SG-PR of the


sizes and mounting type shown on the plans and outlet
schedule. Grilles shall have a 3/16-inch thick steel face with
5
/16 -inch diameter holes on 7/16-inch staggered centers. The
sleeve shall be 3/16-inch thick and shall be stitch welded to
the face and along the entire length of all sleeve seams.

SG-PRA ALUMINUM ROUND PERFORATED FACE

Maximum security grilles shall be Titus Model SG-PRA of


the sizes and mounting type shown on the plans and outlet
schedule. Grilles shall have a 0.125-inch aluminum face
with 5/16-inch diameter holes on 7/16-inch staggered centers.
The sleeve shall be 0.125 inch aluminum and shall be stitch
welded to the face and along the entire length of all sleeve
seams.

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel or aluminum. Damper must be
operated from the face of the grille or rear operated.
The grille finish shall be #26 white. The finish shall be an
anodic acrylic paint, baked at 315F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film.
The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION

Model
SG-PR
SG-PRA
SG-PRT

Aluminum
Steel Transfer

Width

XX
None

Angle Frame
Shipped
loose for field
welding

O
AF

Angle Mounting

SPECIFICATIONS

Steel Damper
AG-15
Rear Operated
Steel Damper
AG-15

4 to 18
in 1-inch
increments

Height

Steel

XX-XXX

J12

Damper Model
None
O
Face Operated
DF

Sleeve Length

XX

XX

White (std.)
Mill

26
04
Finish

Sleeve Barrier Grille

DR

None
Barrier Grille

XX

XX
O
AB
Anchor Bars

None
Anchor Bars

O
BG
XX-XX

Security Products

Maximum Security (continued)

Steel mesh screen - 10-gauge x


#2 mesh wire located between the
face plate and back-up plate.

SQUARE PERFORATED
Steel

SG-PS

Available Model:

SG-PS

Back-up plate - 3/16-inch steel.

The Titus model SG-PS is used in areas


of maximum security and/or minimum
supervision where absolute grille integrity
must be maintained.

Sleeve - 3/16-inch steel.

The SG-PS effectively prevents the


concealment of dangerous or potentially lethal
objects or other contraband of concern to
authorities.

All welded construction.

STANDARD CONSTRUCTION
DETAILS

Face plate - 3/16-inch steel plate


with 2-inch square holes, 1-inch
fret bars and 1-inch border.

Standard Finish - #26 white.

OPTIONS

Angle Frame - 1 x 1 x 3/16inch. Steel angle iron shipped


loose for field welding. Mill finish.

Anchor Bars - -inch diameter


steel bars, 3-inch in height.
Positioned 3 inches from back of
face plate on top and bottom
of sleeve.

Face Operated Damper - AG-15


steel opposed blade damper. Slot
operated from face of the grille.
Rear Operated Damper - AG-15
steel opposed blade damper. Slot
operated from rear of the grille.
Sleeve Barrier Grille - constructed
of -inch diameter steel bars with
maximum 6-inch opening.
Finish - #04 Mill.

www.titus-hvac.com | www.titus-energysolutions.com

SG-PS

SG-PS
3/16" Steel
Face Plate

3/16"

Backer Plate
Height plus 2"

10 Gauge x #2
Wesh Wire

1"
2"

2" 1"

Height

Sleeve Length

Width

Optional Mounting
Angle Frame

Width plus 2"


Notes:
1. For standard product, width and height should be
specified in even 1-inch increments.

2. Typical mounting is accomplished by using an angle


frame (11/2 x 11/2 x 3/16-inch) shipped loose for field
welding.

SG-PS

Dimensions Available
Width:
Height:
Sleeve Length:

Steel
Sleeve

6 to 30 inches
4 to 30 inches
4 to 18 inches in 1-inch
increments

All dimensions are in inches.

J13

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

PERFORMANCE DATA

J14

SG-PS
Nominal
Duct
Size
(in.)

Nominal
Duct
Area
sq. ft

Hole
Area
sq. ft

6x6

0.25

0.11

12X12

1.00

0.44

18X18

2.25

1.00

24x24

4.00

1.78

30x30

6.25

2.78

Face Velocity (fpm)


Velocity Pressure
Total Pressure
Neck Velocity
Airflow, cfm
NC (Noise Criteria)
Throw, Ft.
Airflow, cfm
NC (Noise Criteria)
Throw, Ft.
Airflow, cfm
NC (Noise Criteria)
Throw, Ft.
Airflow, cfm
NC (Noise Criteria)
Throw, Ft.
Airflow, cfm
NC (Noise Criteria)
Throw, Ft.

150
275
400
525
0.000 0.001
0.002
0.003
0.005 0.017
0.037
0.063
67
122
178
233
17
31
44
57
13
1-2-5
2-5-9
4-7-11 6-9-13
67
122
178
233
19
1-3-10 5-9-18 9-13-23 12-17-26
150
275
400
525
14
22
2-5-15 7-14-27 13-20-34 17-26-39
267
489
711
933
16
25
3-6-20 9-18-37 18-27-45 23-35-52
417
764
1111
1458
18
27
3-8-25 11-23-46 22-33-57 29-44-65

Data obtained from tests conducted in accordance


with ANSI/ASHRAE Standard 70-2006.
All data based upon supply performance.
All pressures are in inches of water.
The negative static pressure for return performance is
equal to the total pressure of supply at the same cfm.

650
0.005
0.097
289
72
19
7-10-14
289
25
14-20-29
650
29
22-31-43
1156
31
29-41-58
1809
33
36-51-72

775
0.007
0.138
344
86
24
9-11-16
344
30
17-22-31
775
34
26-33-47
1378
36
34-45-63
2153
38
43-56-79

900
0.010
0.186
400
100
29
10-12-17
400
35
20-24-34
900
38
29-36-51
1600
41
39-48-68
2500
43
49-60-85

1025
0.013
0.241
456
114
33
10-13-18
456
39
21-26-36
1025
42
31-38-54
1822
45
42-51-72
2847
47
52-64-91

1150
0.016
0.303
511
128
36
11-14-19
511
42
22-27-38
1150
46
33-41-58
2044
48
44-54-77
3194
50
55-68-96

Throw values are for terminal velocities of 150,


100 and 50 fpm under isothermal conditions.
See the section Engineering Guidelines, in
this catalog for throw information.
Noise Criteria values are based on a
room absorption of 10 dB.
Dash (-) in space indicates NC value less than 10.
Return NC is 2 NC higher than
supply NC at the same cfm.

Security Products

SUGGESTED SPECIFICATIONS

Available Model:

SG-PS





Steel
Square Perforated
Wire Mesh

SG-PS STEEL SQUARE PERFORATED FACE & WIRE MESH

Maximum security grilles shall be Titus Model SG-PS of the


sizes and mounting type shown on the plans and outlet
schedule. Grilles shall have a 3/16-inch thick steel face with
a 3/16-inch thick steel back-up plate. The face of the grille
shall have 2-inch square holes on 3-inch centers backed by
10-gauge x # 2 woven steel screen. Back-up plate shall be
stitch welded in place and shall be constructed with the hole
pattern to match the face. The sleeve shall be 3/16-inch thick

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315 F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film.
The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.
The manufacturer shall provide published performance data
for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Damper Model
None
O
DF
Face

Sleeve Length
4 to 18
in 1-inch
increments

Height

Model
Steel
SG-PS
Width

XX
None

Angle Frame
Shipped
loose for field
welding

O
AF

Sleeve Barrier Grille

Operated

XX
White (std.)
Mill

Rear
Operated

DR

XX

XX

26
04
Finish

None
Barrier Grille

XX

O
BG

www.titus-hvac.com | www.titus-energysolutions.com

and shall be stitch welded to the face plate and along the
entire length of sleeve seams.

MAXIMUM SECURITY SQUARE PERFORATED

XX-XX

O
AB
Anchor Bars

None
Anchor Bars

Angle Mounting

SPECIFICATIONS
J15

The Titus model SG-3300RL is a medium


security grille for sidewall applications. Heavy
gauge steel louvers welded to a steel sleeve
that extends through the wall make this an
exceptionally strong bar grille.

Steel mesh screen: 10-gauge x #2


mesh wire located behind louvers
and secured by steel angles
welded in position.
Standard Finish - #26 White.

STANDARD CONSTRUCTION
DETAILS

Sleeve: 14-gauge steel.

All welded construction.

OPTIONS

Angle Frame - 1 x 1 x 3/16-inch


steel angle iron shipped loose for
field welding. Frame is mill finish.

Anchor Bars - -inch diameter


steel bars, 3 inches in height.
Positioned 3 inches from back of
face plate on top and bottom of
sleeve.
SG-3300RL

SG-3300RL

WIDTH PLUS 1 3/4"


Notes:
1. For standard product, width and height should be
specified in even 1-inch increments.

1 3/4"

3/4"
HEIGHT MINUS

Rear Operated Damper - AG-35B


steel opposed blade damper. Slot
operated from rear of the grille.
Sleeve Barrier Grille - constructed
of -inch diameter steel bars with
maximum 6-inch opening.
Finish - #04 Mill.

4"

8"

134"

OPTIONAL MOUNTING
ANGLE FRAME

2. Typical mounting is accomplished by using an angle


frame (11/2 x 11/2 x 3/16-inch) shipped loose for field
welding.

Dimensions Available
Width:
Height:
Sleeve Length:

Face Operated Damper - AG-35B


steel opposed blade damper.
Lever operated from face of
the grille.

SLEEVE LENGTH

114"

WIDTH MINUS 3/8"

J16

HEIGHT PLUS

SG-3300RL

38B Deflection
3/8-inch Blade
Spacing

HEIGHT MINUS 3/16"

Available Model:

SG-3300RL



Louvers: 14-gauge steel louvers


on -inch centers penetrating
through the sleeve and welded
at both ends. Each louver is
reinforced by interlocking support
bars spaced on 6-inch centers.

HEIGHT MINUS 5/16"

www.titus-hvac.com | www.titus-energysolutions.com

STEEL FIXED BARS

Border: 16-gauge steel frame


with reinforced, welded
mitered corners.

Security Products

Medium Security
SG-3300RL

6 to 30 inches
4 to 30 inches
4 to18 inches in 1-inch increments
All dimensions are in inches.

Security Products

PERFORMANCE DATA

Nom.
Duct
Size

Nom.
Duct
Area

Core Core Velocity, (fpm)


Area
Velocity Pressure
( ft2 )
Total Pressure

8x8

0.44

0.356

9x9

0.56

0.461

16x16

1.78

1.575

20x20

2.78

2.509

26x26

4.69

4.317

Airflow, cfm
Noise Criteria
Throw, Ft.
Airflow, cfm
Noise Criteria
Throw, Ft.
Airflow, cfm
Noise Criteria
Throw, Ft.
Airflow, cfm
Noise Criteria
Throw, Ft.
Airflow, cfm
Noise Criteria
Throw, Ft.

300
0.006
0.038

400
0.010
0.068

107
142
15
7-12-17 11-13-19
138
184
16
8-13-19 13-15-22
472
630
13
22
14-25-35 23-28-40
753
1004
15
24
18-31-44 29-36-51
1295
1727
17
26
24-41-58 38-47-66

Data obtained from tests conducted in accordance


with ANSI/ASHRAE Standard 70-2006.
All data based upon supply performance.
All pressures are in inches of water.
The negative static pressure for return performance is
equal to the total pressure of supply at the same cfm.

500
0.016
0.107

600
0.022
0.154

700
0.031
0.209

800
0.040
0.273

1000
0.062
0.427

1100
0.075
0.517

1200
0.090
0.615

178
22
12-15-21
230
23
14-17-24
787
28
26-32-45
1255
30
33-40-57
2158
33
43-52-74

214
27
13-17-23
277
29
15-19-27
945
34
28-35-49
1505
36
36-44-62
2590
38
47-58-81

249
32
15-18-25
323
33
17-20-29
1102
39
31-38-53
1756
41
39-47-67
3022
43
51-62-88

285
36
16-19-27
369
37
18-22-31
1260
43
33-40-57
2007
45
41-51-72
3453
47
54-66-94

356
43
17-21-30
461
44
20-24-34
1575
49
37-45-63
2509
51
46-57-80
4317
54
61-74-105

391
46
18-22-32
507
47
21-25-36
1732
52
38-47-67
2760
54
48-59-84
4749
57
64-78-110

427
48
19-23-33
553
49
22-27-38
1890
55
40-49-69
3011
57
51-62-88
5180
59
66-81-115

Throw values are for terminal velocities of 150,


100 and 50 fpm under isothermal conditions.
See the section Engineering Guidelines, in
this catalog for throw information.
Noise Criteria values are based on a
room absorption of 10 dB.
Dash (-) in space indicates NC value less than 10.
Return NC is 2 NC higher than
supply NC at the same cfm.

www.titus-hvac.com | www.titus-energysolutions.com

SG-3300RL

PERFORMANCE DATA
J17

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

steel woven screen secured in place by steel angles. The


sleeve shall be 14-gauge steel. Grilles shall be all welded
construction.

MEDIUM SECURITY STEEL FIXED BARS


Available Model:

SG-3300RL








Steel
Fixed Bars

38B Deflection
3/8-inch Blade Spacing

SG-3300RL STEEL WITH 38B DEFLECTION FIXED BARS

Medium security grilles shall be Titus Model SG-3300RL of


the sizes and mounting type shown on the plans and outlet
schedule. The fixed deflection louvers shall be parallel to
the long dimension of the grille or grille. Grilles shall be
constructed with 14-gauge steel louvers with 38 deflection.
Louvers shall be spaced on -inch centers surrounded by
a 16-gauge steel frame. Louvers shall extend through the
frame on both ends and will be welded to the outside of
the frame. The frame shall be reinforced at the corners.
Louvers shall be reinforced every 6 inches with support bars
welded in place. Louvers shall be backed by 10-gauge x #2

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

Damper Model
None
O
Face Operated
DF

Sleeve Length

Width

XX
None

Angle Frame
Shipped
loose for field
welding

Steel Damper
AG-35B
Rear Operated
Steel Damper
AG-35B

4 to 18
in 1-inch
increments

Height

SG-3300RL

O
AF

Angle Mounting

SPECIFICATIONS

The grille finish shall be #26 white. The finish shall be an


anodic acrylic paint, baked at 315F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film.
The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.

MODEL NUMBER SPECIFICATION

Model
Steel

J18

Optional opposed blade volume damper shall be constructed


of heavy gauge steel. Damper must be operated from the
face of the grille or rear operated.

XX

XX

White (std.)
Mill

26
04
Finish

Sleeve Barrier Grille

DR

None
Barrier Grille

XX

XX
O
AB
Anchor Bars

None
Anchor Bars

O
BG
XX-XX

Security Products

ALUMINUM FIXED BARS


blade spacing
0B Deflection

SG-1500FL

Available Model:

SG-1500FL


Sleeve: 0.09-inch aluminum sleeve


is welded to the frame.
All welded construction.

OPTIONS
Titus Model SG-1500FL is an all aluminum
security grille ideal for shower areas. The
rust proof construction makes this grille an
excellent choice for areas exposed to constant
humidity.

STANDARD CONSTRUCTION
DETAILS

Louvers: 3/16-inch x -inch


welded aluminum bars with zero
degree deflection.

Angle Frame - 1 x 1 x -inch


aluminum angle shipped loose for
field welding. Frame is mill finish.

Anchor Bars - -inch diameter


aluminum bars, 3 inches in height.
Positioned 3 inches from back of
face plate on top and bottom
of sleeve.
Face Operated Damper - AG-15-AA
aluminum opposed blade damper.
Slot operated from face of the
grille.

SG-1500FL

Sleeve Barrier Grille - constructed


of -inch diameter aluminum bars
with maximum 6-inch opening.
Finish - #04 Mill.

Sleeve Length

Height plus 1"

6"
Maximum O.C.

"

Width minus "

Height
minus "

Optional Mounting
Angle Frame

Width plus 1"

2. Typical mounting is accomplished by using an angle


frame (11/2 x 11/2 x 3/16-inch) shipped loose for field
welding.

Dimensions Available

SG-1500FL

Notes:
1. For standard product, width and height should be
specified in even 1-inch increments.

Width:
Height:
Sleeve Length:

Rear Operated Damper - AG-15-AA


aluminum opposed blade damper.
Slot operated from rear of the
grille.

www.titus-hvac.com | www.titus-energysolutions.com

Minimum Security
SG-1500FL

6 to 30 inches
4 to 30 inches
4 to18 inches in 1-inch increments
All dimensions are in inches.

J19

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

SG-1500FL
Nominal Nominal Core Core Velocity, (fpm)
Duct
Duct
Area Velocity Pressure
Size
Area
sq. ft
Total Pressure
Airflow, cfm
6x6
0.25 0.187
Noise Criteria
Throw, Ft.
Airflow, cfm
8x8
0.44 0.356
Noise Criteria
Throw, Ft.
Airflow, cfm
9x9
0.56 0.461
Noise Criteria
Throw, Ft.
Airflow, cfm
12x12
1.00 0.857
Noise Criteria
Throw, Ft.
Airflow, cfm
16x16
1.78 1.575
Noise Criteria
Throw, Ft.
Airflow, cfm
18x18
2.25 2.015
Noise Criteria
Throw, Ft.
Airflow, cfm
20x20
2.78 2.509
Noise Criteria
Throw, Ft.
Airflow, cfm
24x24
4.00 3.660
Noise Criteria
Throw, Ft.
26x26

4.69

4.317

Airflow, cfm
Noise Criteria
Throw, Ft.

30x30

6.25

5.793

Airflow, cfm
Noise Criteria

PERFORMANCE DATA

Throw, Ft.

J20

300
0.006
0.038
56
6-9-14
107
8-12-19
138
9-14-22
257
12-19-29
472
11
17-25-40
604
12
19-29-45
753
13
21-32-50
1098
14

400
0.010
0.068
75
8-11-16
142
13
11-16-22
184
14
12-18-25
343
16
17-24-34
630
19
23-33-46
806
20
26-37-52
1004
21
29-41-58
1464
22

1000
0.062
0.427
187
36
15-18-25
356
38
20-25-35
461
39
23-28-39
857
42
31-38-54
1575
44
42-52-73
2015
45
48-58-83
2509
46
53-65-92
3660
47
64-7926-39-61 34-50-70 43-56-79 50-61-86 54-66-93 57-70-99
111
1295
1727
2158
2590
3022
3453
4317
15
23
29
34
38
42
48
58-7162-7670-8528-42-66 37-54-76 47-60-85 54-66-94
101
108
121
1738
2317
2896
3476
4055
4634
5793
16
24
30
35
39
43
49
63-7768-8372-8881-9932-49-77 43-63-88 54-70-99
108
117
125
140

Data obtained from tests conducted in accordance


with ANSI/ASHRAE Standard 70-2006.
All data based upon supply performance.
All pressures are in inches of water.
The negative static pressure for return performance is
equal to the total pressure of supply at the same cfm.

500
0.016
0.107
93
17
10-13-18
178
19
13-17-25
230
20
15-20-28
428
23
21-27-38
787
25
28-36-52
1007
26
32-41-58
1255
27
36-46-65
1830
28

600
0.022
0.154
112
22
11-14-19
214
24
16-19-27
277
25
18-22-31
514
28
24-29-42
945
30
33-40-57
1209
31
37-45-64
1505
32
41-50-71
2196
33

700
0.031
0.209
131
26
12-15-21
249
28
17-21-29
323
29
19-23-33
600
32
26-32-45
1102
34
35-43-61
1410
35
40-49-69
1756
36
44-54-77
2562
38

800
0.040
0.273
149
30
13-16-22
285
32
18-22-31
369
33
20-25-35
686
36
28-34-48
1260
38
38-46-65
1612
39
43-52-74
2007
40
48-58-82
2928
41

1100
0.075
0.517
205
38
15-19-26
391
41
21-26-36
507
42
24-29-41
943
44
33-40-56
1732
47
44-54-77
2216
48
50-61-87
2760
49
56-68-97
4026
50

1200
0.090
0.615
224
41
16-19-28
427
43
22-27-38
553
44
25-31-43
1028
47
34-42-59
1890
49
46-57-80
2418
50
52-64-90
3011
51
58-71-101
4392
53

67-82-117 70-86-122
4749
51

5180
53

73-90-127 76-94-132
6372
52
85-104147

6951
54
88-108153

Throw values are for terminal velocities of 150,


100 and 50 fpm under isothermal conditions.
See the section Engineering Guidelines, in
this catalog for throw information.
Noise Criteria values are based on a
room absorption of 10 dB.
Dash (-) in space indicates NC value less than 10.
Return NC is 2 NC higher than
supply NC at the same cfm.

Security Products

SUGGESTED SPECIFICATIONS

Available Models:

SG-1500FL








Aluminum
Fixed Bars
Spacing
0B Deflection

Optional opposed blade volume damper shall be constructed


of heavy gauge aluminum. Damper must be operated from
the face of the grille or rear-operated.
The grille finish shall be #26 white. The finish shall be an
anodic acrylic paint, baked at 315F for 30 minutes. The
pencil hardness must be HB to H. The paint must pass a
100-hour ASTM B117 Corrosive Environments Salt Spray
Test without creepage, blistering or deterioration of film. The
paint must pass a 250-hour ASTM D870 Water Immersion
Test. The paint must also pass the ASTM D2794 Reverse
Impact Cracking Test with a 50-inch pound force applied.

SG-1500FL ALUMINUM WITH 1/2-INCH SPACED FIXED


BARS

Minimum security grilles shall be Titus Model SG-1500FL of


the sizes and mounting type shown on the plans and outlet
schedule. The fixed deflection louvers shall be available
parallel to the long or short dimension of the grille. Grilles
shall be constructed with 3/16-inch thick extruded aluminum
louvers on -inch centers, set at 0 deflection, with heavy
vertical aluminum tubes on 6-inch centers passing through
the center of each louver. Vertical supports shall be welded
to the frame on both ends. The frame shall be -inch thick

The manufacturer shall provide published performance data


for the grille. The grille shall be tested in accordance with
ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION


Damper Model
None
O
Face Operated
DF

Sleeve Length
Model
Aluminum
SG-1500FL
Width

XX
None

Angle Frame
Shipped
loose for field
welding

Steel Damper
AG-15-AA
Rear Operated
Steel Damper
AG-15-AA

4 to 18
in 1-inch
increments

Height

O
AF

XX

XX

White (std.)
Mill

26
04
Finish

Sleeve Barrier Grille

DR

None
Barrier Grille

XX

XX

www.titus-hvac.com | www.titus-energysolutions.com

aluminum extrusion welded at the corners. Grilles shall be


of all welded construction. The sleeve shall be 0.09-inch
aluminum welded securely to the frame.

MINIMUM SECURITY ALUMINUM FIXED BARS

O
BG
XX-XX

O
AB
Anchor Bars

None
Anchor Bars

Angle Mounting

SPECIFICATIONS
J21

Security Products

SG-TDC
LOUVERED CORE, LATTICE FACE
Available Model:

SG-TDC

STANDARD CONSTRUCTION
DETAILS

Steel

The Titus model SG-TDC is typically used in


areas of constant supervision or lobbies or
entryways. The SG-TDC is designed where
minimum security is still necessary and
maximum performance is required. This
ceiling diffuser assembly utilizes the often
specified Titus TDC diffuser with a heavy
gauge steel lattice grille field attached to the
diffuser.

Face plate:12-gauge steel with


13
/16-inch square holes and 3/16inch fret bars.

Louvered diffuser:Titus Model


TDC border 1 (surface mount)
with 1-, 2-, 3- or 4-way blow
pattern.
Screw holes provided in face plate.
Tamper proof screws provided by
others.

SG-TDC

www.titus-hvac.com | www.titus-energysolutions.com

Minimum Security (continued)

OPTIONS

Face Operated Damper - AG-35B


steel opposed blade damper. Slot
operated from face of the diffuser.
Rear Angle Frame - 1 x 1
x 3/16-inch steel angle frame
with -inch x 20 NC weld nuts
(bolts provided by others).

SG-TDC

Ceiling Opening =
Duct plus 3"

Duct plus 59/16"

Duct
Duct minus "

"

13/16"

3/16"

2"
12 Gauge
Face Plate
Duct plus 59/16"

"

5/16"

Optional 1 x 1 x 3/16-inch
Rear Angle Frame

Holes located to
match diffuser

Dia. Holes

Screw Hole Location per Side


Neck Size

Ceiling

6-inch

SG-TDC

Rear Angle
Frame

Location and
Number of Holes
One hole at
center line

9 to 18 inches

Two holes 3
inches from edge

21 to 24 inches

Three holes
equally spaced

SG-TDC
Diffuser

Note: All security screws are to be provided by others due to wall/ceiling variations, desired material, specifications, screw
style and local requirements. Typical mounting is performed by inserting screws through the lattice face and the diffuser and
attaching directly to the ceiling.

J22

All dimensions are in inches.

Security Products

PERFORMANCE DATA

Nominal
Duct Area

6x6
AD 0.25 ft2

0.25

9x9
AD 0.56 ft2

0.44

12 x 12
AD 1.00 ft2

0.56

15 x 15
AD 1.56 ft2

1.00

18 x 18
AD 2.25 ft2

1.78

21 x 21
AD 3.06 ft2

2.25

24 x 24
AD 4.00 ft2

2.78

Neck Velocity
Total Pressure
Airflow, cfm
NC (Noise Criteria)
Throw, ft.
Airflow, cfm
NC (Noise Criteria)
Throw, ft.
Airflow, cfm
NC (Noise Criteria)
Throw, ft.
Airflow, cfm
NC (Noise Criteria)
Throw, ft.
Airflow, cfm
NC (Noise Criteria)
Throw, ft.
Airflow, cfm
NC (Noise Criteria)
Throw, ft.
Airflow, cfm
NC (Noise Criteria)
Throw, ft.

100
0.006
25
1-1-2
55
1-1-2
100
1-1-2
155
1-2-4
225
1-2-4
305
1-3-5
400
1-3-5

Neck velocities are in feet per minute.


All pressures are in inches of water.
Throw values, measured in feet, are for
terminal velocities of 150, 100 and 50 fpm.
See the section, Engineering Guidelines,
in this catalog for throw information.
Noise Criteria (NC) values based on a room
absorption of 10 dB, re 1012 watts.
Dividing lines denote ranges of NC values.
The negative static pressure for the return is equal
to the total pressure of the supply at the same cfm.

200
300
400
0.022
0.050
0.089
50
75
100
19
3-5-7
1-2-3
1-3-5
110
170
225
12
22
1-3-5
3-5-8
5-7-12
200
300
400
17
26
4-6-9
2-4-6
6-9-13
310
625
470
20
29
2-5-8 4-8-12 8-11-12
450
675
900
11
24
33
3-7-11 4-9-16 8-13-22
610
920
1225
13
26
35
3-8-13 7-11-19 10-16-25
800
1200
1600
15
28
37
4-6-14 8-13-22 12-13-29

500
0.137
125
23
3-6-9
280
29
6-9-13
500
33
7-10-16
780
36
10-14-23
1125
40
11-17-28
1530
42
13-20-30
2000
44
16-23-36

600
0.197
150
29
4-7-11
335
35
7-10-16
600
39
9-13-21
935
42
11-17-27
1350
46
13-20-32
1835
47
15-23-37
2400
50
18-27-43

700
0.275
175
33
5-7-12
390
40
8-11-18
700
44
10-14-21
1090
47
10-19-30
1575
50
14-22-36
2140
53
17-26-42
2800
54
20-30-47

NC-40

NeckSize
(Inches)

NC-30

NC-50

NC-20

www.titus-hvac.com | www.titus-energysolutions.com

SG-TDC

Return Noise Criteria is 2 NC greater than


the supply NC at the same cfm.
Dash () in space indicates Noise
Criteria value less than 10.
Data obtained from tests conducted in accordance
with ANSI/ASHRAE Standard 702006.
Performance is based on standard construction.

PERFORMANCE DATA
J23

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

MINIMUM SECURITY LOUVERED


CORE, LATTICE FACE

provided with screw holes in the face for surface mounting.


Tamper proof screws are to be provided by others according
to structural requirements.

Available Model:

SG-TDC

Optional opposed-blade volume damper shall be constructed


of heavy gauge steel. Damper must be operable from the
face of the diffuser by removing the spring loaded inner core
assembly.

Steel

SG-TDC

Minimum security diffusers shall be Titus Model SG-TDC


for fixed, horizontal discharge pattern. These diffusers
shall consist of an outer frame assembly of the sizes and
mounting types shown on the plans and outlet schedule.
A square inlet shall be an integral part of the frame
assembly and a transition piece shall be available to
facilitate attachment of round duct. An inner core assembly
consisting of fixed deflection louvers shall be available in
1-, 2-, 3- or 4-way horizontal discharge patterns. The inner
core assembly must be removable in the field without tools
for easy installation, cleaning, or damper adjustment. All
units shall be constructed of heavy gauge steel and shall
be available in sizes of 6 x 6 inches through 24 x 24 inches.
All units shall be covered with a 12-gauge steel face with
13
/16 -inch square holes on 1-inch centers. All units shall be

Height
White (std.)

SG-TDC
Width

X
1
Border Type

Surface Mount

Finish
26
XX
4-Way
Square

Note: For available sizes, please refer to model TDC in section F.

SPECIFICATIONS

The manufacturer shall provide published performance data


for the diffuser. The diffuser shall be tested in accordance
with ANSI/ASHRAE Standard 70-2006.

MODEL NUMBER SPECIFICATION

Model
Steel

J24

The diffuser finish shall be #26 white. The finish shall be


an anodic acrylic paint, baked at 315F for 30 minutes.
The pencil hardness must be HB to H. The paint must
pass a 100-hour ASTM B117 Corrosive Environments Salt
Spray Test without creepage, blistering or deterioration of
film. The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.

Damper Model
None
O
Face Operated
DF
Steel Damper
AG-35B

XX
A4

XX

XXX

O
RAF
Rear Angle Frame
None

Rear Angle Frame

Pattern

Security Products

Minimum Security (continued)

LATTICE FACE, 13/16-INCH SQUARE


HOLES ON 1-INCH CENTERS
Steel
Aluminum

The Titus model SG-LFO can be used in any


area where additional security is required.

STANDARD CONSTRUCTION
DETAILS

Face Plate - Steel:12-gauge with


13
/16-inch square holes on 1
centers - 66% free area.

Standard Finish - #26 White.


Screw Hole Location: Screw hole
quantities and locations vary
by duct size. Please consult the
factory for screw hole quantity
and location.

SG-LFO

Available Models:

SG-LFO

SG-LFO-AA

Face Plate - Aluminum: -inch


aluminum with 13/16-inch square
holes on 1 centers - provides
66% free area. 3/16-inch
diameter screw holes provided
in face plate. Tamper proof
screws provided by others.

OPTIONS

Face Plate with Round Hole


Pattern - 5/16-inch diameter holes
on 7/16-inch staggered centers.

No Screw Holes.

www.titus-hvac.com | www.titus-energysolutions.com

SG-LFO

Finish - #04 Mill.


SG-LFO

Width plus 1"


13

/16"

115/32"
Typ.

Width
minus 13/16"

Height
plus 1"
Height
minus 13/16"
3/16"

3/16"

Dia. Holes

Dimensions Available
6 to 30 Inches
4 to 30 Inches

Available in 1-inch increments


Notes:
1. These models are attached to the wall or ceiling
using screws inserted through the face of the grille
sandwiching it to the wall or ceiling. Screws to be
provided by others due to varying wall and ceiling
characteristics. All screws should comply with
local requirements and the controlling engineers
specifications.

3. The SG-LFO is also available in stainless steel for corrosive


environments.
4. For standard product, width and height should be
specified in even 1-inch increments.

2. The SG-LFO is dimensioned the same as the 300/350


Series grilles (Duct + 13/4-inch overall dimensions) so the
SG-LFO can be field assembled to the grille to provide a
secured air passage.
All dimensions are in inches.

SG-LFO, SG-LFO-AA

Width:
Height:

J25

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

MINIMUM SECURITY LATTICE FACE


Available Models:

SG-LFO

SG-LFO-AA

SG-LFO-AA - ALUMINUM LATTICE FACE WITH 13/16-INCH


SQUARE HOLES ON 1-INCH CENTERS
Minimum security lattice face shall be Titus Model SG-LFOAA and shall be constructed of 0.125 -inch aluminum with
13
/16-inch square holes on 1-inch centers. Units shall be
available in sizes from 6 x 4 inches through 30 x 30 inches.

Steel
Aluminum

Minimum security lattice face shall be Titus Model SG-LFO


and shall be constructed of 12-gauge steel with 13/16-inch
square holes on 1-inch centers.

MODEL NUMBER SPECIFICATION


Model
SG-LFO
SG-LFO-AA

Height
White (std.)

Width

Finish
26
XX

XX

Screw
Holes (std.)

S1
R1
Face Hole Pattern

Square 13/16 Holes on 1 Centers


Round 5/16 Holes on 7/16 Staggered Centers

SPECIFICATIONS

The lattice face finish shall be #26 white. The finish shall
be an anodic acrylic paint, baked at 315F for 30 minutes.
The pencil hardness must be HB to H. The paint must
pass a 100-hour ASTM B117 Corrosive Environments Salt
Spray Test without creepage, blistering or deterioration of
film. The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.

Units shall be available in sizes from 6 x 4 inches through


30 x 30 inches. Units shall be mounted using tamper proof
security screws to meet structural requirements. Tamper
proof screws shall be provided by the installing contractor
according to job requirements.

XX-XXX-XX

J26

Units shall be mounted using tamper proof security screws


to meet structural requirements. Tamper proof screws shall
be provided by the installing contractor according to job
requirements.

SG-LFO - STEEL LATTICE FACE WITH 13/16-INCH SQUARE


HOLES ON 1-INCH CENTERS

SH

O
Fastening

None

Security Products

Minimum Security (continued)

Steel
Aluminum

The Titus model SG-LFF can be used in any


area where additional security is required.
This minimum security lattice face is an
economical alternative return grille for
minimum security areas.

STANDARD CONSTRUCTION
DETAILS

Screw Hole Location - Screw hole


quantities and locations vary by
duct size. Please consult the
factory for screw hole quantity and
location.

OPTIONS

Finish - #04 Mill.

29/16"

1"

Duct Width plus 1"

3/16"

Face Plate

Plaster Frame

Duct minus "

"

Duct Height plus 2"

5/16"

3/16"
Dia. Holes

13/16"

Face Plate with Round Hole


Pattern: 5/16-inch diameter holes
on 7/16-inch staggered centers.

Face Operated Damper - Steel:


AG-15 steel opposed blade
damper. Slot operated from face
of the grille.

Duct Width plus 2"

Face Operated Damper Aluminum: AG-15-AA aluminum


opposed blade damper. Slot
operated from face of the grille.

Duct

Face Plate - Steel: 12-gauge steel


with 13/16-inch square holes on
1-inch centers - provides 66% free
area.

SG-LFF

Standard Finish - #26 White.

Duct Height plus 1"

Available Models:

SG-LFF

SG-LFF-AA

Face Plate - Aluminum: -inch


aluminum with 13/16-inch square
holes on 1-inch centers - provides
66% free area. 3/16-inch diameter
screw holes provided in face plate.
Tamper proof screws provided by
others.

SG-LFF

LATTICE FACE WITH PLASTER FRAME,


13
/16-INCH SQUARE HOLES ON 1-INCH
CENTERS

www.titus-hvac.com | www.titus-energysolutions.com

SG-LFF

Optional Opposed
Blade Damper and
Sleeve (Add " to
overall Height when
fully open)

Dimensions Available
Width:
Height:

6 to 30 Inches
4 to 30 Inches

Available in 1-inch increments

3. For standard product, width and height should be


specified in even, 1-inch increments.

2. The SG-LFF is also available in stainless steel for corrosive


environments.
All dimensions are in inches.

SG-LFF

Notes:
1. These models are attached to the wall or ceiling using
screws inserted through the face of the grille. Screws
to be provided by others due to varying wall and
ceiling characteristics. All screws should comply with
local requirements and the controlling engineers
specifications.

J27

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

/16-inch square holes on 1-inch centers. An aluminum


mounting frame shall be provided. Units shall be available in
sizes from 6 x 4 inches through 30 x 30 inches.

MINIMUM SECURITY LATTICE FACE


WITH PLASTER FRAME

13

Available Models:

SG-LFF

SG-LFF-AA

Units shall be mounted using tamper proof security screws


to meet structural requirements. Tamper proof screws shall
be provided by the installing contractor according to
job requirements.

Steel
Aluminum

SG-LFF STEEL LATTICE FACE WITH FRAME AND 13/16INCH SQUARE HOLES ON 1-INCH CENTERS

Minimum security lattice face shall be Titus Model SG-LFF


and shall be constructed of 12-gauge steel with 13/16-inch
square holes on 1-inch centers. A steel mounting frame shall
be provided. Units shall be available in sizes from
6 x 4 inches through 30 x 30 inches. Units shall be mounted
using tamper proof security screws to meet structural
requirements. Tamper proof screws shall be provided by the
installing contractor according to job requirements.

The lattice face finish shall be #26 white. The finish shall
be an anodic acrylic paint, baked at 315F for 30 minutes.
The pencil hardness must be HB to H. The paint must
pass a 100-hour ASTM B117 Corrosive Environments Salt
Spray Test without creepage, blistering or deterioration of
film. The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.

SG-LFF-AA ALUMINUM LATTICE FACE WITH FRAME


AND 13/16-INCH SQUARE HOLES ON 1-INCH CENTERS

Minimum security lattice face shall be Titus Model SG-LFFAA and shall be constructed of 0.125-inch aluminum with

MODEL NUMBER SPECIFICATION


Model
SG-LFF
SG-LFF-AA

Height
White (std.)

XX-XXX-XX

Width
S1
R1
Face Hole Pattern

Square 13/16 Holes on 1 Centers


Round /16 Holes on 7/16 Staggered Centers

SPECIFICATIONS

J28

Finish
26
XX

XX

None
Face Operated
Steel Damper
AG-15
Face Operated
Alum. Damper
AG-15-AA

O
DF
DFA

Damper Model

Security Products

Available Model:
SG-BG-FM

SG-BG-FM

Frame - 2 x -inch steel with


welded corners.

BARRIER WITH FRAME

Standard Finish - #26 White.

The Titus model SG-BG-FM is a framed barrier


grille typically provided in wall openings
between secure and non-secure areas.

All Welded Construction.

OPTIONS

Vertical Bars Only - -inch


diameter steel bars on 6-inch
centers.

STANDARD CONSTRUCTION
DETAILS

Barrier Grille - Constructed of


-inch diameter steel bars and
2 x -inch steel flat bars
located on 6-inch centers.

Horizontal Bars Only - 2 x


-inch steel bars on 6-inch
centers.

www.titus-hvac.com | www.titus-energysolutions.com

Barrier Grilles
SG-BG-FM

Finish - #04 Mill.


SG-BG-FM

Width
2"

6"

All Junction
Points
Welded

Height
6"

Dimensions Available
Width:
Height:

6 to 30 Inches
4 to 30 Inches

Available in 1-inch increments

2. For standard product, width and height dimensions


should be specified in even, 1-inch increments.

All dimensions are in inches.

SG-BG-FM

Notes:
1. Titus SG-BG security bars are constructed from hot-rolled
carbon steel (SAE 1008, 1010 or 1015). The standard steel
hardness can range from 100-126 Brinell depending on
composition and heat treatment. This material does not
comply with ASTM Standards A628, A629 or A750.

J29

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

BARRIER GRILLE WITH FRAME


Available Model:
SG-BG-FM

SG-BG-FM

Barrier grilles shall be Titus Model SG-BG-FM (steel) of the


sizes and mounting type shown on the plans and outlet
schedule. Grilles shall be constructed with -inch diameter
vertical bars spaced on 6-inch centers with 2 x -inch
horizontal bars spaced on 6-inch centers. Round bars
passing through horizontal flat bars shall be welded on one
side of the flat bar at all intersections.

MODEL NUMBER SPECIFICATION


Barrier Bar Specifications
B
diameter vertical bars and 2 x

Height

Model
SG-BG-FM
Width

H
V

White (std.)

SPECIFICATIONS

Mill

J30

The barrier grille finish shall be #26 white. The finish shall
be an anodic acrylic paint, baked at 315F for 30 minutes.
The pencil hardness must be HB to H. The paint must
pass a 100-hour ASTM B117 Corrosive Environments Salt
Spray Test without creepage, blistering or deterioration of
film. The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.

26
04
Finish

horizontal flat bars on 6 centers


2 x flat bars on 6 centers
diameter vertical bars on 6 centers

Security Products

Barrier Grilles (continued)

BARRIER WITH SLEEVE


Available Model:
SG-BG-SLV
The Titus model SG-BG-SLV is a barrier
mounted inside a 3/16 thick sleeve for
installation in a wall or other opening as a
completed unit. This unit effectively maintains
security between secure and non-secure
areas. Duct connections can be quickly made
at both ends. This makes the SG-BG-SLV an
ideal installation in security walls.

SG-BG-SLV

STANDARD CONSTRUCTION
DETAILS

Sleeve Barrier Grille - Constructed


of -inch diameter steel bars with
maximum opening of 6 inches.
Sleeve: 3/16-inch steel.
Angle Frames - Two frames
constructed of 1 x 1 x 3/16inch steel angle iron shipped loose
for field welding. Frames are
mill finish.

Standard Finish - #26 White.


All Welded Construction.

OPTIONS

Finish - #04 Mill.

SG-BG-SLV

Width plus 33/8"

Height
plus 33/8"

Sleeve Length

Angle Frame
shipped loose
for field welding

www.titus-hvac.com | www.titus-energysolutions.com

SG-BG-SLV

Height

Bar Location
1"
Width

Dimensions Available
Width:
Height:
Sleeve Length:

6 to 30 Inches
4 to 30 Inches
4 to 18 inches in 1-inch increments

2. Typical mounting is accomplished by using an angle


frame (11/2 x 11/2 x 3/16-inch) shipped loose for field
welding.

All dimensions are in inches.

SG-BG-SLV

Notes:
1. For standard product, width and height should be
specified in even 1-inch increments.

J31

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

1 x 3/16-inch angle frames shall be shipped loose for field


welding in place.

BARRIER GRILLE WITH SLEEVE


Available Model:
SG-BG-SLV

SG-SD-SLV

SG-BG-SLV Barrier grilles shall be Titus Model SG-BG-SLV


(steel) of the sizes and mounting type shown on the plans
and outlet schedule. Grilles shall be constructed with -inch
diameter bars with maximum spacing of 6 inches. All barrier
grilles shall be surrounded by a 3/16-inch sleeve. The sleeve
shall be stitch welded along the entire length. Two 1 x

MODEL NUMBER SPECIFICATION


Height

Model

White (std.)

SG-BG-SLV

SPECIFICATIONS

J32

Width

XX
4 to 18
in 1-inch
increments

Sleeve Length

Finish
26
XX

The barrier grille finish shall be #26 white. The finish shall
be an anodic acrylic paint, baked at 315BF for 30 minutes.
The pencil hardness must be HB to H. The paint must
pass a 100-hour ASTM B117 Corrosive Environments Salt
Spray Test without creepage, blistering or deterioration of
film. The paint must pass a 250-hour ASTM D870 Water
Immersion Test. The paint must also pass the ASTM D2794
Reverse Impact Cracking Test with a 50-inch pound force
applied.

Security Products

Options
Sleeve Barrier Grille (BG)

Face Operated Damper (DF)

6" Max

6"
Max

D plus "

3"

D plus "

Angle Frame shipped loose for


field installation.

Barrier grille inside security grille


sleeve. Horizontal and vertical bars
are both -inch steel.

SG-PS, SG-PR are slot operated. SG1500, SG-3300 are lever operated.

Rear Operated Damper (DR)

Anchor Bars (AB)

Anchor Bars (AB)

3"

3"

3"

3"

3"

www.titus-hvac.com | www.titus-energysolutions.com

Angle Mounting Frame (AF)

3"

3"

All models are slot operated.

For sleeve widths less than 12


inches. Steel anchor bars are
-inch diameter and 3 inches tall.
Aluminum anchor bars are -inch
diameter and 3 inches tall.

For sleeve widths equal to or greater


than 12 inches. Steel anchor bars
are -inch diameter and 3 inches
tall. Aluminum anchor bars are
-inch diameter and 3 inches tall.

SUGGESTED SPECIFICATIONS
OPTIONS



Face Operated Damper


Rear Operated Damper
Anchor Bars
Barrier Grille

REAR OPERATED DAMPER

ANCHOR BARS

BARRIER GRILLE

All grilles or diffusers shall have a faceoperated opposed-blade damper.


For security grilles with duct widths
under 12 inches, one anchor bar is
supplied on the top and bottom of
the sleeve. Each bar is located three
inches from the back of the faceplate
and three inches from the edge of the
sleeve. For security grilles with duct
widths equal to or greater than 12
inches, two anchor bars are supplied
on the top and bottom of the sleeve.
Each bar is located three inches from
the back of the faceplate and three
inches from the edge of the sleeve.
All dimensions are in inches.

All grilles or diffusers shall have a rearoperated opposed-blade damper.


A barrier grille shall be provided
in all grilles with a height or width
dimension exceeding 10 inches.
Barrier grilles shall be constructed of
-inch diameter steel vertical bars
with maximum spacing of 6-inch and
-inch diameter steel horizontal bars
with maximum spacing of 6 inches.
Barrier grilles shall be welded into the
grille sleeve and have all intersecting
points welded.

OPTIONS

Note: Check the corresponding model


description to determine availability of
each option by model.

FACE OPERATED DAMPER

J33

Security Products

www.titus-hvac.com | www.titus-energysolutions.com

Application Suggestions

APPLICATION SUGGESTIONS

J34

Model
Number

Security
Level

Description

Usage

Material

SG-PS

Designed as a maximum security grille with 3/16-inch


thick face plate with 2-inch square holes backed by
Maximum
10-gauge x # 2 mesh and a 3/16-inch thick
back-up plate.

Cells and other high security areas where


maximum security inmates may be left
unattended for long periods of time.

Steel

SG-SD

Designed as a maximum security grille with 3/16-inch


Maximum thick steel face plate and 9/32-inch diameter holes on
staggered centers. Sleeve is 3/16-inch thick steel.

Cells, dayrooms and other high security


areas where maximum security inmates may
be left unattended for long periods of time.

Steel

SG-PR

Designed as a maximum security grille with 3/16-inch


thick steel face plate and 5/16-inch diameter holes
Maximum
staggered on 7/16-inch centers. Sleeve is 3/16-inch
thick steel.

Cells, dayrooms, and other high security


areas where maximum security inmates may
be left unattended for long periods of time.

Steel

Medium

Designed as a medium security grille with -inch


thick aluminum face plate and 5/16-inch diameter
holes staggered on 7/16-inch centers. Sleeve is
-inch thick aluminum.

Secure areas where high structural integrity


must be maintained while the grille is
exposed to wet conditions such as showers.

Aluminum

Medium

Medium security grille with 16-gauge steel borders


and 14-gauge steel blades set on 38 deflection
angle. Blades are backed by 10 gauge -inch steel
mesh for added safety.

Medium security cells, dayrooms, any place


where a medium security prisoner may be
left unattended for long periods of time.

Steel

SG-1500FL

Minimum

Minimum security grille with -inch thick extruded


aluminum frame and -inch thick extruded
aluminum louvers spaced -inch apart.

Minimum security areas such as showers,


reception rooms, and other security areas
where minimum security inmates are under
close supervision.

Aluminum

SG-TDC

Minimum

Minimum security diffuser with 1-, 2-, 3- or 4-way


blow. 12-gauge lattice face with 13/16-inch square
holes on 1-inch centers.

Ceilings throughout lobbies, entry ways, and


other areas under constant supervision.

Steel

SG-BG-SLV

Max-Min

-inch diameter steel bars on maximum 6-inch


centers with -inch diameter crossbars on maximum
6-inch centers. Standard sleeve is 3/16-inch thick
Wall and roof penetration barriers.
with two 1 x 1 x 3/16-inch angle frames for wall
mounting.

Steel

SG-BG-FM

Max-Min

-inch diameter steel bars on 6-inch centers with


2 x -inch crossbars on 6-inch centers.

Steel

SG-PRA

SG-3300RL

Notes:
1. Security grilles may be used in psychiatric facilities,
hospitals, high security buildings, zoos and other
buildings requiring secure HVAC outlets.
2. Careful attention must be given to areas where
inmates or patients are prone to suicide attempts. The
best prevention of suicide is to place the grille in an
inaccessible area and use grilles with minimized face
openings.
3. Titus defers to the job engineer to make the decision of
which grille and what configuration to use.

Wall and roof penetration barriers.

Security Products

Typical Installation Methods


Angle Frame Mounting
The grille is slipped into the wall
opening and angles are welded in
place from the back side. The duct
is then connected to the rear of the
grille sleeve.

Wall
Optional
Grout

Field Mounted Angle Frame


welded in place

Grille
Face
Wall
D plus "

Grille
Sleeve
Duct

www.titus-hvac.com | www.titus-energysolutions.com

MODELS: SG-PS, SG-SD, SG-PR, SG-PRA, SG-PRT, SG-3300RL, SG-1500FL

Tape, Screw, or
Weld Duct to
Sleeve O.D.

Anchor Bar Mounting


The grille is grouted into the wall
as the wall is built. Tabs are factory
welded to the sleeve to ensure the
grille cannot be slipped out of the
wall. The duct is then connected to
the rear of the sleeve.

Wall
Anchor Bars

Grille
Face
Duct Size

Grille
Sleeve
Duct
Tape, Screw, or
Weld Duct to
Sleeve O.D.

The grille is grouted into the wall


as the wall is built. The two factory
welded grille faces keep it from
being slipped out of the wall.

Wall

Face

Face
X"

Duct Size

Sleeve

INSTALLATION METHODS

Transfer Grille Installation

J35

Security Products
60%

40%

30%

1.0
0.9

50%

PRESSURE LOSS THROUGH PERFORATED PLATE BASED ON FREE AREA


20%

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

0.8
0.7
0.6
0.5
0.4

0.3

0.2

Are

0.15

Fre

Negative Static Pressure (IN.WG.)

0.25

0.1
0.09
0.08
0.07
0.06
0.05
0.04

PERFORMANCE DATA

0.03
0.025
0.02

0.015

0.01
100

J36

150

200

250

300

400

500

600 700 800 900 1000

Core Velocity
(feet/min. or cfm.ft 2)

1500

2000

grille & diffuser accessories

K
www.titus-hvac.com | www.titus-energysolutions.com

www.titus-hvac.com | www.titus-energysolutions.com

Table of Contents

Grille & Diffuser Accessories

grille & diffuser products


GRD Products.................................................................................................................................................................................K3

overview
Overview.........................................................................................................................................................................................K6

air balancing devices


Round Dampers..............................................................................................................................................................................K7
AG-100, D-100 (Sliding Blade)................................................................................................................................................K7
AG-75 (Opposed Blade)...........................................................................................................................................................K8
D-75 (Opposed Blade).............................................................................................................................................................K8
AG-85 (Butterfly).....................................................................................................................................................................K9
Square and Rectangular Dampers..................................................................................................................................................K9
AG-15, AG-15-AA, AG-15-SS (Opposed Blade).....................................................................................................................K10
AG-15-HD (Opposed Blade)...................................................................................................................................................K10
AG-35, AG-35-AA, AG-35B, AG-35B-AA (Opposed Blade)....................................................................................................K11
AGR-35-AAS (Opposed Blade, Remote Cable Operated)......................................................................................................K12
AG-95, AG-95-AA (Opposed Blade).......................................................................................................................................K13
AG-125 (Double Blade)..........................................................................................................................................................K14
Damper with Grid.........................................................................................................................................................................K15
AG-65....................................................................................................................................................................................K15
AG-65-S, AG-65-L..................................................................................................................................................................K16
Equalizing Grid..............................................................................................................................................................................K17
EG..........................................................................................................................................................................................K17
EG-S, EG-L.............................................................................................................................................................................K18
Volume Extractors.........................................................................................................................................................................K19
AG-45, AG-225......................................................................................................................................................................K19
Turning Vanes...............................................................................................................................................................................K20
TV..........................................................................................................................................................................................K20

mounting frames
Rapid Mount.................................................................................................................................................................................K21
TRM, TRM-S.........................................................................................................................................................................K21
TDRM ...................................................................................................................................................................................K22
Plaster Frames..............................................................................................................................................................................K23
PF, PFA, PF-SS.......................................................................................................................................................................K23

sectorizing baffle

GRD ACCESSORIES

SB.................................................................................................................................................................................................K24

K2

duct accessories
FlexRight.......................................................................................................................................................................................K25
FlexaBoot......................................................................................................................................................................................K26

Grille & Diffuser Accessories

GRD Accessories Products

AG-100

D-100

AG-75

D-75

www.titus-hvac.com | www.titus-energysolutions.com

AIR BALANCING DEVICES

pages: K7-K20

K
AG-15 (-AA, -SS)

AG-15-HD

AG-35 (-AA, -35B, -35B-AA)

AGR-35-AAS

AG-95 (-AA)

AG-125

AG-65 (-S, -L)

EG (-S, -L)

AG-45

AG-225

TV

AIR BALANCING DEVICES

GRD ACCESSORIES

AG-85

Designed for quick access and easy adjustment.


Steel, aluminum or stainless steel material.
Engineered to minimize noise, turbulance and resistance.

K3

Grille & Diffuser Accessories

www.titus-hvac.com | www.titus-energysolutions.com

GRD Accessories Products (continued)

MOUNTING FRAMES

pages: K21-K23

PF (-A,-SS)

TRM, (-S)

PLASTER FRAMES

RAPID MOUNT

RAPID MOUNT

Can be installed as either surface mount


or recessed.
Steel, aluminum or stainless steel construction.

For use in plaster and sheet rock ceilings.


Lay-in style plaster frame that makes
installation of GRD products simple and easy.
Extruded aluminum or steel construction.
Available in custom sizes.

For use in plaster and sheet rock ceilings.


Works with all Titus 24 x 24 lay-in type
diffusers to a 30 x 30 lay-in module.
Aluminum construction.

SECTORIZING BAFFLE

GRD ACCESSORIES

page: K24

K4

TDRM

SB
SPECIAL APPLICATIONS
Used to baffle one or more quadrants of the diffuser inlet to achieve a desired air pattern.
Steel construction.

GRD Accessories Products (continued)

Grille & Diffuser Accessories

FlexRight

FlexaBoot

FLEX DUCT INSTALLATIONS

RETURN AIR APPLICATIONS

An acoustical return sound boot that eliminates


sound transfer in open plenum ceilings.
Available in two flex duct diameters - 10 & 16.

Designed to form flexible duct into highly efficient 90B elbow.


Improves airflow and saves energy by eliminating kinks and restrictions.
Works in retrofitting applications or new building construction.
Universal design fits flexible duct sizes - 4 to 16.

www.titus-hvac.com | www.titus-energysolutions.com

DUCT ACCESSORIES

pages: K25-K26

GRD ACCESSORIES
K5

www.titus-hvac.com | www.titus-energysolutions.com

Overview

GRD ACCESSORIES

K6

Effective air balancing begins with the balancing provisions


that are designed into the HVAC system and Titus
offers a complete line of GRD accessories to meet these
requirements. Titus air balancing devices are available in
several nominal sizes and can be mounted directly to the
diffuser inlet or duct mounted. They feature high quality,
precision construction and can be ordered as accessories
with the diffuser or grille, or as stand alone units.
Easy to select and specify.
Designed for quick access and adjustment.
Accurate, smooth and predictable in
their response to adjustment.
Engineered for the least possible noise,
turbulence and air resistance.

Grille & Diffuser Accessories

Grille & Diffuser Accessories

ROUND DAMPERS (SLIDING BLADE)

D-100

AG -100

Available Models:
AG-100
D-100
Note: For 6-, 8-, 10-, 12- and 14-inch
Round Necks.

Model AG-100 is separately


mounted in the duct, just above
the diffuser. Adjusts with a
screwdriver from the face side of
the diffuser.

Adapter Ring

Actuator Vane 1

Movable
Vanes 3

Support Vane 1

Operator
Slot

Pushnut

Support Vane 1

D-100

1"

1"
Actuator Vane 1

Duct Diameter "

AG-100

Model D-100 is the same


as AG-100, but without the
mounting ring. Mounts directly
on the diffuser neck, flush with
the top. Useful in flex duct
or where height is limited.
Galvanized steel material.
Mill finish.

Movable
Vanes 3
Pushnut

Operator
Slot

D = Duct Diameter "

Gang operated radial blades slide,


each blade over the next, at right
angles to the airflow.

www.titus-hvac.com | www.titus-energysolutions.com

Air Balancing Devices


AG-100, D-100

Spring Clip

Spring Clip

MODEL NUMBER SPECIFICATION


Model
AG-100
D-100

Finish

Neck Mounted

Mill

XX

AG-100, D-100

XX-XXX

Duct Mounted

04

Neck Size 6, 8, 10,


12, 14

All dimensions are in inches.

K7

Grille & Diffuser Accessories

AG-75
OPPOSED BLADE
Available Model:
AG-75
Note: The photograph represents sizes
14 inches and larger.

Nominal Size A
6
4
7
4
8
5
10
5
12
6

Nominal Size A
14
3
15
3
16
3
18
4

Gang operated opposed blades


(three sets on sizes 6 through 12
inches, four sets on 14 though 20
inches and six sets on 24 through
36 inches). Can be mounted
directly into hard duct above
diffuser neck. The damper can be
easily adjusted from the face side
of the diffuser.
Nominal Size A
20
5
24
3
30
5
36
7

Listed Size minus "

Airflow
1"

1"

5/32"

"

Mounting
Tab

2"

9/64"

Dia. for
#8 Sheet Metal
Screws by
Others

x " slot for


#8 Sheet Metal
Screws by Others

Operator
Slot

Not recommended for


use with flexible duct.
Steel material.
84 black finish.

Damper Blade Open


A

AG-75

www.titus-hvac.com | www.titus-energysolutions.com

Air Balancing Devices (continued)

Airflow

7/16"

Listed Size minus "

Operator
Slot

D-75
Available Model:
D-75
Note: For 6-, 7-, 8-,
10- and 12-inch Round Necks.

AG-75, D-75

MODEL NUMBER SPECIFICATION

K8

Model
AG-75
D-75

Mounts directly to the diffuser


neck. Three sets of gang operated
opposed blades distribute air
evenly over the diffuser face.
Quickly, easily adjusted from
the face side of the diffuser.
Galvanized steel material.
Nominal Size
B
Mill finish.
6
41/16
7
4
8
415/16
10
413/16
12
6

D-75

OPPOSED BLADE

Listed Size minus "

Duct Mounted

Finish

Neck Mounted

Mill

XX-XX
Neck Size

XX

04

6, 8, 10, 12, 14,


15, 16, 18, 20, 24,
30, 36
Note: The Model D-75 is available in
neck sizes 6, 7, 8, 10, & 12 only.

111/16"

"
Operator
Slot

All dimensions are in inches.

5/32" Dia. for


#8 Sheet Metal
Screws by Others

Grille & Diffuser Accessories

Air Balancing Devices (continued)

BUTTERFLY
Duct Mounted

AG-85

Available Model:

AG-85

A low cost damper for volume control in round neck


diffusers. Continuously adjustable. Friction pivots hold
the heavy gauge blades at the desired setting. Quickly,
easily adjusted from the face side of the diffuser.
Not recommended for use with flexible duct.
Steel material

www.titus-hvac.com | www.titus-energysolutions.com

AG-85

84 black finish

A
Operator
Slot
1"

Nominal Size
A
4
17/16
5
115/16
6
27/16
7
215/16
8
37/16
10
47/16
12
57/16
14
67/16
15
615/16
16
77/16
18
87/16
20
97/16
24
117/16

"
Listed Size minus "
MODEL NUMBER SPECIFICATION
Model
AG-85

Finish
Butterfly Damper

Neck Size

XX

84

AG-85

XX-XX

Black

4, 5, 6, 8, 10, 12, 14,


15, 16, 18, 20, 24

All dimensions are in inches.

K9

Grille & Diffuser Accessories

AG-15
SQUARE AND RECTANGULAR DAMPERS - OPPOSED BLADE
Available Models:

AG-15

AG-15-AA

AG-15-SS

AG-15

Galvanized Steel.
Aluminum
304 Stainless Steel

Note: Available only for 300/350 Series, 50F,


8R and 8F models.
AG-15
Neck mounted.
NOMINAL SIZE MINUS 1/2

www.titus-hvac.com | www.titus-energysolutions.com

Air Balancing Devices (continued)

Uses steel s-clips for easy mounting


and removal.
Steel and 304 Stainless Steel models
are slot operated.

Aluminum model is lever operated.


114"

Mill Finish.

158"

NOMINAL SIZE MINUS 1/16"

Note: Available in one piece construction up to 24 x 18. Large sizes are made in
multiple sections up to 48 x 48 inches.

AG-15-HD
OPPOSED BLADE
Steel
Heavy duty
neck-mounted

AG-15-HD

Available Model:

AG-15-HD




Note: Available only for model DL.

AG-15, AG-15-HD

MODEL NUMBER SPECIFICATION

K10
K10

Model
AG-15
AG-15-AA
AG-15-SS
AG-15-HD

AG-15-HD

Steel

23/8

Aluminum
304 Stainless Steel

Operator

Finish

Steel Heavy Duty

Screwdriver

Mill

XX-XX-XX
Duct Size

See model DL, page I57, for


available duct sizes.

213/16

Nominal Size minus

Note: Only available to fit drum louver models.

All dimensions are in inches.

Grille & Diffuser Accessories

Air Balancing Devices (continued)

Model numbers with the suffix AA


denote aluminum construction
with miscellaneous steel parts.

OPPOSED BLADE
Steel
Neck Mounted
Aluminum
Neck Mounted
Steel
Duct Mounted
Aluminum
Duct Mounted

AG-35

Available Models:

AG-35




AG-35-AA




AG-35B




AG-35B-AA


Available Operators:

#1 Slot Operated (Supply)

#8 Slide (lever)
Operated (Return)

AG-35

Gang-operated opposed blades


meter air volume precisely with
minimum air disturbance.

www.titus-hvac.com | www.titus-energysolutions.com

AG-35

21/16"

Model AG-35 installs in the duct


immediately behind the diffuser.
Model AG-35B installs in the duct,
separated from the diffuser.

Listed Duct Size minus 1/16"

Listed Duct Size


minus 9/16"

Note: Available in one piece construction up to 30 x 12. Large sizes are made in
multiple sections up to 48 x 48 inches.

MODEL NUMBER SPECIFICATION


Model
AG-35
AG-35B

Steel, Neck
Mounted

Duct Size

Steel, Duct
Mounted

4 x 4 thru
48 x 48

XX-XX-XX

XX x XX

Model
AG-35-AA
AG-35B-AA

04

L
S

Duct Size

Aluminum,
Duct Mounted

4 x 4 thru
48 x 48

XX x XX

Finish
Mill

04

Operator
Screwdriver

AG-35

Blade
Orientation
Parallel to Long
Dimension
Parallel to Short
Dimension

Screwdriver

Aluminum,
Neck Mounted

XX-XX-XX

Mill

Operator

Blade
Orientation
Parallel to Long
Dimension
Parallel to Short
Dimension

Finish

All dimensions are in inches.

K11

Grille & Diffuser Accessories

AGR-35-AAS
OPPOSED BLADE, REMOTE CABLE OPERATED
AGR-35-AAS

www.titus-hvac.com | www.titus-energysolutions.com

Air Balancing Devices (continued)

Available Model:
AGR-35-AAS
Model AGR-35-AA-S is a remote cable-operated damper
for duct-mounted applications, separate from the
diffuser.
Gang-operated opposed blades meter air volume
precisely with minimal air disturbance.
Constructed of heavy-duty extruded aluminum with
miscellaneous steel parts.
Cable available in lengths of 2 feet through 12 feet in 1
foot increments.

Cable assembly shipped loose for field installation.


Dampers require one to three cables for operation
based on width. Sizes 6 to 16 inches require one cable,
18 to 32 inches require two cables, and 34 to 48 inches
require three cables.

Listed Size minus "


(long dimension)

2"

Listed Size minus "


(short dimension)

AGR-35-AAS

MODEL NUMBER SPECIFICATION


Model
Aluminum, Short Blades, DuctMounted, Remote Cable-Operated

AGR-35-AAS

XX x XX

Duct Size 6 x 6 thru


48 x 18

K12
K12

Operator
Cable

04
Mill

Finish

All dimensions are in inches.

Grille & Diffuser Accessories

Air Balancing Devices (continued)

Available Model:

AG-95

AG-95-AA

AG-95, AG-95-AA

OPPOSED BLADE
Steel
Aluminum

For use with all Titus Series TDC louvered diffusers, as


well as with all perforated diffusers having square or
rectangular necks.
The blades distribute air evenly over the diffuser neck
opening, in addition to regulating the airflow accurately.
An operating lever is accessible from the face side of
the diffuser.

Attaches quickly with sheet metal screws directly to the


diffuser neck (screws provided by others.)
Also available with a slot operator for use with Titus
TDV and TDX model diffusers.

www.titus-hvac.com | www.titus-energysolutions.com

AG-95, AG-95-AA

K
2"

Listed Size Minus "

Listed Duct Size

MODEL NUMBER SPECIFICATION

Steel

AG-95

Finish

6 x 4 thru
48 x 48

XX x XX
Operator

Blade
Orientation

Screwdriver

Parallel to Long
Dimension

Parallel to Short
Dimension

Lever

Mill

X
1
8

04

Duct Size

Model

6 x 4 thru
48 x 48

Aluminum

AG-95-AA

Blade
Orientation

04
Mill

Parallel to Long
Dimension

Parallel to Short
Dimension

All dimensions are in inches.

XX x XX

Finish

AG-95, AG-95-AA

Duct Size

Model

K13

Grille & Diffuser Accessories

AG-125
DOUBLE BLADE
Available Model:
AG-125

AG-125

www.titus-hvac.com | www.titus-energysolutions.com

Air Balancing Devices (continued)

Note: Model AG-125 is for Series TDC diffusers only.


Two sets of independently adjustable blades in one
damper. The air-entering set deflects air from the main
duct into the take-off. The air leaving the unit equalizes
airflow into the diffuser.

Extruded aluminum blades, steel frame.

A suffix S on the model number denotes blades


parallel to the short dimension, L denotes blades
parallel to the long dimension.

O
A

O = D minus 1/16
A = D minus 9/16

1
1
D = Nominal Opening

MODEL NUMBER SPECIFICATION

AG-125

Model

K14
K14

AG-125

Duct Size

Finish

6 x 4 thru
48 x 48

04 Mill
26 White

XX x XX

XX

Operator

Blade
Orientation

Screwdriver

Parallel to Long
Dimension

Parallel to Short
Dimension

All dimensions are in inches.

Grille & Diffuser Accessories

Air Balancing Devices (continued)

DAMPER WITH GRID


For Round Necks

AG-65

Available Model:

AG-65

Quickly installed with sheet metal screws flush with


entrance to the branch take-off. The damper blade
opens upstream in the main duct to catch the air and
divert it into the take-off.
Individually adjustable vanes with friction pivots
equalize velocities entering the diffuser neck.

A = .6"
X Listed Size

Nominal Sizes: 4, 5, 6, 7, 8, 10, 12,


14, 15, 16, 18, 20, 24, 30, 36

Operator
Slot
1"

Individually
Adjustable
Vanes

www.titus-hvac.com | www.titus-energysolutions.com

AG-65

1"

2"
5/32"

Mounting
Tabs
Listed Size minus "
Listed Size

"

" Dia. Hole for


Sheet Metal Screw
(#14 Max.) by Others
Duct By Others

Note: Dimension A is the recommended maximum blade depth.

MODEL NUMBER SPECIFICATION


Finish

Model

04 Mill
84 Back

Round Damper with Grid

AG-65

XX

XX

AG-65

Neck Size 4, 5, 6, 7, 8, 10, 12,


14, 15, 16, 18, 20,
24, 30, 36

All dimensions are in inches.

K15

Grille & Diffuser Accessories

AG-65 (S, L)
DAMPER WITH GRID
Available Models:

AG-65-S

AG-65-L

AG-65 (S, L)

www.titus-hvac.com | www.titus-energysolutions.com

Air Balancing Devices (continued)

For Square and Rectangular Necks.

Quickly installed with sheet metal screws flush with the


entrance to the branch take-off (screws by others.) The
damper blade opens upstream in the main duct to
catch the air and divert it into the take-off.
Individually adjustable vanes with friction pivots
equalize velocities entering the diffuser neck.

A = .6"
X Listed Size

The suffix S or L denotes vanes parallel to the short


or long dimension. Maximum length/width ratio is 2:1.
Maximum size is 30 x 30 inches.

Operator
Slot
1"

Individually
Adjustable
Vanes

1"
13/16"

"

Mounting
Tabs
Listed Size minus "
Listed Size

"

AG-65 (S, L)

MODEL NUMBER SPECIFICATION

K16
K16

Duct Size

Model
AG-65

4 x 4 thru
30 x 30

Blade
Orientation

XX x XX

XX
04 Mill
84 Black

Parallel to Long
Dimension

Parallel to Short
Dimension

Finish

All dimensions are in inches.

" Dia. Hole for


Sheet Metal Screw
(#14 Max.) by Others
Duct By Others

Grille & Diffuser Accessories

Air Balancing Devices (continued)

EQUILIZING GRID
Available Model:

EG For Round Necks.
EG

Equalizes the airflow into the branch duct or diffuser


neck. Also gives directional control of airflow. Specially
designed Titus airfoil vanes give maximum control
with minimum noise and turbulence. The vanes are
individually adjustable, with friction pivots to hold the
desired settings.
For nominal round duct sizes 4 through 36 inches.

Nominal
Size

Nominal
Size

15

14

16

15

18

17

20

19

24

23

10

30

29

12

11

36

35

14

13

www.titus-hvac.com | www.titus-energysolutions.com

EG

Mounting Tabs

K
Individually
Adjustable
Vanes
Dia. Hole for
Sheet Metal Screw
(#14 Max.) by Others
A (Max. OD of Grid) = D Minus "
D = Nominal Duct Opening

1"
2"

"

MODEL NUMBER SPECIFICATION


Model

Finish

Equalizing Grid

04 Mill

EG

XX

04

Neck Size 4, 5, 6, 7, 8, 10, 12,


14, 15, 16, 18, 20,
24, 30, 36

EG

All dimensions are in inches.

K17

Grille & Diffuser Accessories

EG (S, L)
EQUILIZING GRID
Available Models:
EG-S

EG-L

EG (S, L)

www.titus-hvac.com | www.titus-energysolutions.com

Air Balancing Devices (continued)

For Square and Rectangular Necks.

Equalizes the airflow into the branch duct or diffuser


neck. Also gives directional control of airflow. Specially
designed Titus airfoil vanes give maximum control with
minimum noise and turbulence.

The suffix S or L denotes vanes parallel to the short


or long dimension.

The vanes are individually adjustable, with friction


pivots to hold the desired settings.

" Dia. Hole for


Sheet Metal Screw
(#14 Max.) by Others

Duct By Others

1"
OA

D = Listed
Duct Opening

Mounting Tabs

Individually
Adjustable
Vanes

1"

"

OA Dimension = D minus "


D = Listed Duct Opening

1"
2 11/16"

MODEL NUMBER SPECIFICATION


Duct Size

Model

4 x 4 thru
30 x 30

Equalizing Grid

EG (S, L)

EG

K18
K18

Blade
Orientation

XX x XX

XX
04 Mill
26 White

Parallel to Long
Dimension

Parallel to Short
Dimension

Finish

All dimensions are in inches.

Grille & Diffuser Accessories

Air Balancing Devices (continued)

Available Models:

AG-45

AG-225

AG -45

1 spacing
2 spacing

AG-45, AG-225

VOLUME EXTRACTORS

Gang-operated parallel vanes


are fully adjustable from open to
closed. The carefully designed
vane cross-section minimizes
pressure drop and turbulence.
The extractor provides uniform air
distribution across the stub duct or
diffuser neck.

Installation Notes

Factory assembled, installs easily


with two sheet metal screws
(screws by others.) Choice of
three operators as illustrated
below. Maximum recommended
size is 36 x 12 inches. Maximum
duct velocity is 2500 fpm.

O = D minus 5/16
AG-225 = 2

If the tops and bottoms of the main


and branch ducts are in different
planes, branch duct extensions above
and below the extractor will improve
performance.

AG-45 = 1

www.titus-hvac.com | www.titus-energysolutions.com

AG-45, AG-225

O = D minus
X = D minus

30 Max Opening

Supporting
Foot

D = Nominal Opening

The installer is to provide a supporting


foot if D exceeds 12 inches or the
bottom of the main and branch ducts
are not in the same plane.

With Operator #1
Push-Pull Double Wire
Locked with Sheet Metal
Screw.

MODEL NUMBER SPECIFICATION


Duct Size
1 Spaciong
2 Spaciong

XX-XXX

Parallel to Long
Dimension
Parallel to Short
Dimension

XX x XX
Operator

Blade
Orientation
L
S

Finish

6 x 4 thru
36 x 12

Mill

Push/Pull
Double Wire

Rotating Shaft
Key Operated
Screw

2
3

04

All dimensions are in inches.

With Operator #3
Key-Operated Screw.
Access through Diffuser
Face.

AG-45, AG-225

Model
AG-45
AG-225

With Operator #2
3/8-inch Square Rotating
Shaft (Young #1) by Others.

K19

Grille & Diffuser Accessories

TV
TURNING VANES
Available Model:

TV Steel


For Square and Rectangular Necks.
TV

www.titus-hvac.com | www.titus-energysolutions.com

Air Balancing Devices (continued)

Fixed vanes deflect the air in a curved path with


minimum pressure drop.
Provides uniform air distribution across the stub duct or
diffuser neck.

Can be set at the desired angle and locked in position


with adjusting wires under screw heads.
Furnished in sizes to fit standard diffuser necks or stub
ducts. Specify the size required.

D minus 7/16

Fixed Steel
Vanes
Adjusting
Wire

30 Maximum

1
Sheet Metal
Screws
(by others)

D = Nominal Duct Opening

MODEL NUMBER SPECIFICATION


Duct Size

Model

6 x 4 thru
36 x 36

Turning Vane

TV

TV

Blade
Orientation

K20

XX x XX

XX
04 Mill
26 White

Parallel to Long
Dimension

Parallel to Short
Dimension

Finish

All dimensions are in inches.

Duct
(by others)

Grille & Diffuser Accessories

RAPID MOUNT
TRM, TRM-S

Available Models:

TRM

TRM-S

Aluminum
Steel

Note: For plaster and sheet rock ceilings.


This lay-in style plaster frame makes installation
of grilles, diffusers and other ceiling components in
plaster and sheet rock ceiling as simple as inserting
them in a standard T-bar type ceiling. The TRM is
an aesthetically pleasing, inexpensive access door
alternative for entry to the plenum space above the
ceiling.

For typical applications, the frame has adjustable


fastening clips which adapt to a variety of plaster
and sheet rock ceiling thicknesses. When heavy duty
support is required, the frame can be suspended with
wire from the building structure.
Accessories such as lights, speakers, ceiling material
cutouts, hidden access panels and other devices may
also be inserted in the frame. Custom sizes are available
in addition to the standard sizes shown below.

Ceiling
Module

Ceiling Opening View

to
B

3/16

12
16
20
24
24
36
48
48
60

x
x
x
x
x
x
x
x
x

12
16
20
12
24
24
12
24
12

Recommended
Ceiling Opening*
B
C
12
12
16
16
20
20
24
12
24
24
36
24
48
12
48
24
60
12

www.titus-hvac.com | www.titus-energysolutions.com

Mounting Frames
TRM, TRM-S

*Check actual dimensions of ceiling


opening before installation.

MODEL NUMBER SPECIFICATION


Model
TRM

XXX-X

Rapid Mount
Frame, Steel

Finish
04 Mill
01 Aluminum
26 White

XX x XX

TRM, TRM-S

TRM-S

Rapid Mount
Frame, Aluminum

XX

Module Size See chart above for


available sizes.

All dimensions are in inches.

K21

Grille & Diffuser Accessories

TDRM
Available Model:

TDRM

Aluminum

The TDRM allows T-bar, lay-in type diffusers (border


type 3) to be installed in 30 x 30 ceiling tees.
Can be used with all Titus diffusers that are 24 x 24
lay-in type.
Can be used to access ceiling plenum.
Diffuser with flex connection can be lifted
out of frame to access ceiling space.

MODEL NUMBER SPECIFICATION


Finish

Model

TDRM

TDRM

K22

30 X 30

XXX-X
Module Size

XX x XX

04 Mill
01 Aluminum
26 White

XX

TDRM

www.titus-hvac.com | www.titus-energysolutions.com

Mounting Frames (continued)

Grille & Diffuser Accessories

Mounting Frames (continued)

PLASTER FRAMES
PF, PFA, PF-SS

Available Models:

PF

PFA

PF-SS

Steel
Aluminum
304 Stainless Steel

Not available in sizes over 48


inches in either dimension.
Wall opening should be listed
duct size plus -inch to listed
duct size plus -inch.
Models PF, PFA, and
PF-SS can be installed as either
surface mount or recessed.

Duct plus 2"

www.titus-hvac.com | www.titus-energysolutions.com

PF, PFA, PF-SS

Duct plus 1"


5

/16"
"

"

1"
Duct plus "

Duct Size plus "


"
1"

All dimensions are in inches.

5/16"

PF, PFA, PF-SS

D plus 2"
Duct plus 1"

K23

Available Model:
SB
For special applications, where it is necessary to baffle
one or more quadrants of the diffuser inlet to achieve
a desired air pattern.

SB

www.titus-hvac.com | www.titus-energysolutions.com

Grille & Diffuser Accessories

Sectorizing Baffle
SB

Furnished in multiples of 90B to fit most round neck


diffusers.
Steel, painted black.
Shipped loose for field installation by others.

K
A

90

SB

Fasten to inside
of diffuser neck
with #8 SMS.
(by others)

K24

All dimensions are in inches.

Inlet Size

10

12

14

15

7.5

Grille & Diffuser Accessories

Available Model:
FlexRight

FlexRight improves airflow and


saves energy by eliminating
kinks and restrictions common
to flexible duct installations
Great for retrofit applications or
new building construction

Made from 100% recycled material


(copolymer polypropylene)

Universal design fits flexible
duct sizes: 4 - 16
UL Listed
Nylon cable ties supplied by others

FlexRight

FlexRight is a radius forming brace


designed to form flexible duct
into highly efficient 90B elbows

Green product that saves


energy by improving airflow

www.titus-hvac.com | www.titus-energysolutions.com

Duct Accessories
FlexRight

FlexRight 90B Elbow


Universal-mount, 1 piece, fully
adjustable, radius-forming brace to
support 4-inch (102-mm) through
16-inch (406-mm) diameter flexible
air ducts

K
Nylon cable ties to secure flex duct
to FlexRight
(ties by others)

FLEXRIGHT
K25

Grille & Diffuser Accessories

FlexaBoot
Acoustically tested assembly
consists of flex duct, FlexRight,
assembly ties & mounting straps

Available Model:
FlexaBoot
FlexaBoot is an acoustical
return sound boot
Designed for ceiling plenum
return air applications

Available in two flex duct


diameters: 10 & 16

Square to round
adapters by others

Eliminates sound transfer


in open plenum ceilings

K
FlexaBoot Sizes:
10 Diameter - flexible duct length is 60
16 Diameter - flexible duct length is 72

Temperature Range: 0B to 200BF


Rated Velocity:

5000FPM

FLEXABOOT

Maximum Rated Pressure (Negative)

K26

1.0 (for 10 diameter size)

1.2 (for 16 diameter size)

Note: Pressure is in inches of WG

FlexaBoot

www.titus-hvac.com | www.titus-energysolutions.com

Duct Accessories (continued)

vav diffusers

L
www.titus-hvac.com | www.titus-energysolutions.com

www.titus-hvac.com | www.titus-energysolutions.com

Table of Contents

VAV DIFFUSERS

L2

VAV Diffusers

vav diffuser products


VAV Diffusers Products.................................................................................................................................................................. L3

overview
Design Features.............................................................................................................................................................................. L4

application guidelines
Application Guidelines.................................................................................................................................................................... L5

vav diffusers
Thermal - T3SQ-4............................................................................................................................................................................. L7
Digital - T3SQ-2............................................................................................................................................................................... L8
Accessories............................................................................................................................................................................. L9
Non-VAV - T3SQ-0......................................................................................................................................................................... L10
Border Types................................................................................................................................................................................. L11
Performance Data......................................................................................................................................................................... L12
Suggested Specifications............................................................................................................................................................. L14
Model Number Specification........................................................................................................................................................ L16

VAV Diffusers

VAV Diffuser Products

T3SQ-4

T3SQ-2

T3SQ-0

THERMAL VAV DIFFUSERS

DIGITAL VAV DIFFUSERS

NON-VAV DIFFUSERS

Configurations
T3SQ-4 - heating/cooling.
Features
Thermally powered VAV control.
Center induction.
Minimum airflow adjustment.
Enhanced pattern controllers
for easy adjustment.

Configurations
T3SQ-2 - heating/cooling.
Features
DDC stand-alone VAV control.
DDC BACnet VAV control.
DDC LonWorks VAV control.
Optional inlet heater.

Configurations
T3SQ-0 - non-VAV supply/return.
Features
Designed to match the T3SQ-4
thermal VAV diffusers.

www.titus-hvac.com | www.titus-energysolutions.com

VAV DIFFUSERS

pages: L7-L15

VAV DIFFUSERS
L3

VAV Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

Overview

DESIGN FEATURES
PERSONALIZED VAV SYSTEMS

Titus brings both accuracy and


flexibility to the variable air volume
(VAV) market with T3SQ VAV diffusers.
The T3SQ combines the functions of a
VAV terminal and a high performance
diffuser in one. The T3SQ modulates
the air volume delivered to a zone
to accurately control cooling and
heating conditions. The unique variable
geometry design results in maximum
air distribution effectiveness at any air
flow, for superior comfort conditions.
T3SQ adds application flexibility by
being able to operate stand-alone with
thermal or analog controls.
In addition to a superior performance
VAV unit, the T3SQ is solidly
constructed with 18-gauge steel.
Available in many frame styles, the
T3SQ can be installed in almost any
ceiling as easily as a standard diffuser.
The architecturally pleasing
design coordinates with any office
environment.
For applications that require system
simplicity, proven technology and
superior comfort, specify the Titus
T3SQ series of VAV diffusers.

Variable geometry diffuser design


maintains jet velocity at all flow
rates, varying air flow pattern
for optimal performance.
Separate cooling and heating
setpoints on thermal T3SQ.
Supply air temperature
provides automatic cooling/
heating changeover on
configurations -4 and -2.
T3SQ-2, digital, can control
up to 14 drones.
Optional electric inlet heater
for applications requiring
supplemental heat (T3SQ-2 only).
Provides accurate, personal
environmental temperature
control to improve productivity
in the office environment.
Superior air distribution
performance provides greater
entrainment, higher Air Diffusion
Performance Index (ADPI) and
better ventilation effectiveness
for Indoor Air Quality (IAQ).
Lower cost per zone of control
than typical VAV terminal
with separate diffusers.
Renovate existing offices or add
zones in problem areas to solve
individual comfort problems.

Thermal VAV Diffuser

Supply air temperature sensor


provides autochangeover from
heating to cooling operation.

DESIGN FEATURES

Easy to turn minimum


airflow adjustment ring.

Single piece backpan


with multiple border types
available to complement
various ceiling designs.

Thermal actuator assembly lifts


and lowers the control disc producing
uniform air pattern in all positions.

L4

Installation and relocation are


made easy.
Constant volume systems can
easily become multi-zoned VAV
systems, for big building comfort
on a small building budget.
Easy and inexpensive to
relocate zones, ideal for use
where office space may be
reconfigured periodically.
Easy to install and operate.
Unique center induction on
thermal T3SQ-4 ensures accurate
readings even at low flows.

Easy to turn heating and cooling setpoint


adjustment rings (heating setpoint adjuster
only available on heating / cooling units).

Venturi tube and center induction


design provide fast and accurate
response to changes in zone temperature.
A tight horizontal air pattern
is achieved by the intelligent
curvature design of the backpan.

Face plaques curved edge


reduces diffuser sound and
creates a smooth appearance.

VAV Diffusers

Application Guidelines
The Titus T3SQ system is ideal for use with a constant
volume system. The T3SQ gives all the advantages
of a VAV system at low pressure conditions and reduced
installation cost. The T3SQ is a low pressure, pressure
dependent, variable air volume (VAV) system. The T3SQ is
designed to operate around 0.15- 0.20 inlet pressure. This
system provides zoned comfort, which is not always possible
with a typical constant volume system.
1. It is recommended that a static pressure controller
such as the Titus ZECV/ZQCV be installed into a
constant volume system when more than 30 percent
of the system airflow is put under the control of T3SQ

diffusers. This minimizes the possibility of delivering


excess air when a portion of the Zcoms are operating at
part load conditions.
2. When an entire constant volume system uses T3SQ
zone control, a ZECV/ZQCV box should be implemented.
The Titus ZECV/ZQCV pressure control terminal should
be sized for 80 percent of the total supply flow, less the
airflow of the smallest zone.
3. Care must be taken when sizing and installing a ZECV/
ZQCV. The unit should be installed as far downstream
from the fan as is practical to maximize supply and
return air mixing. This reduces the risk of the unit
cycling on high or low.

T3SQ
Diffuser

T3SQ
Diffuser

www.titus-hvac.com | www.titus-energysolutions.com

CONSTANT VOLUME SYSTEM APPLICATION


OPTION

Return
24 VAC
24 VAC

ZECV/ZQCV

CV
System

Static
Pressure
Tap

Static
Pressure
Tap

Typical static pressure control by bypassing supply


air using a ZECV/ZQCV terminal.

VARIABLE AIR VOLUME SYSTEM APPLICATION


OPTION
The Titus T3SQ system is ideal for use in buildings where
the advantages of zoned variable air volume (VAV) systems
normally cannot be used due to budget issues or plenum
space constraints.

APPLICATION GUIDE

Typical static pressure control by throttling supply


air using a ZECV/ZQCV terminal.

ZECV/ZQCV

Special care should taken when determining the static


pressure of a VAV system with T3SQ units.

For more information on ZECV and ZQCV, please refer to the Miscellaneous Terminals section of the catalog.

L5

VAV Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

Application Guidelines (continued)

Digital VAV Diffuser

MASTER / DRONE
T3SQ-2 diffusers are all shipped as drone units.
Determination of master units is made through plug and
play cable connections to the thermostat. The units
connected to the thermostat are the master units. All units
daisy chained from the master are drones. Drone diffusers
must be connected to a master diffuser in order to operate.
One power module is required for every 15 diffusers with or
without optional electric reheat. Power module requires 120,
208, 240, 277 VAC line voltage input.
The 4-pin mini-fit cables provide 24VAC power and
communication between diffusers. This cable should be used
between the power module and the first diffuser and also to
connect a master unit to a drone unit.
Blue RJ-45 8-pin cables provide 24VAC power and control
signal between diffusers. RJ-45 cables should be used
Master/Drone Wiring

between diffuser and master controller/thermostat and


between master and drone units.
The Master Communications Module is a central data
collection and distribution point for up to 60 VAV field
diffusers. The device features four diffuser channel inputs,
which can accommodate up to 15 diffusers each. This allows
the users to interface with 60 diffusers per communication
module through a building management system. The
interface software also has a server application which allows
all communication modules on site to be accessed through
the building management system from the i.p. address of
each module. Master communication modules are available
in the following communication protocols:
Standard Master Communication module (Stand-Alone)
Master Communications module with Lonworks gateway
Master Communications module with BACnet gateway
RJ12
4-pin mini fit cable drone unit

P.S.

One master unit can control up to 14


drone units.

APPLICATION GUIDE

P.S. = Power Supply


T = Room Sensor
Master/Drone Wiring With MCM
(Master Communication Module)

P.S. = Power Supply


T = Room Sensor
MCM = Master Communication Module

Master Unit

Drone Unit

Drone Unit

P.S.

Master Unit
T

L6

Drone Unit

RJ12
4-pin mini fit cable drone unit
RJ-9 cable

MCM

Drone Unit

Drone Unit

Drone Unit

VAV Diffusers

THERMAL - T3SQ-4
Heating/Cooling

T3SQ-4

Configurations:

T3SQ-4

The T3SQ-4 is a thermal variable volume diffuser.


The diffuser maintains space temperature by
varying the volume of air delivered to the space.
The amount of air delivered will depend on the
Supply Air Temperature (SAT) (-4 only), the room
temperature setpoint, and the room temperature.
Available in heating/cooling (-4) configuration.
As the volume of air is decreased by the control disc,
the velocity of air is increased, thereby maintaining
the longest throw and best entrainment. Insuring
superior air distribution at all damper positions.
The curvature of the backpan works with the
formed edges of the face panel to deliver a tight
horizontal air pattern, without excessive noise or
pressure drop over the full range of operation.

The T3SQ-4 uses a center induction plug to


accurately measure the room temperature. This
eliminates the need for a wall mounted thermostat
or sensor and provides the most accurate way
of measuring the room air temperature.
Adjustment of the room temperature
setpoint is achieved by rotating the blue
(cooling) only adjustment ring.
Adjustment of the green tab offset
creates a temperature deadband for
heating and cooling setpoints.
Adjustment of minimum airflow is achieved by
rotating the grey minimum airflow adjustment ring.
Standard finish is #26 White.
The face panel and backpan are constructed
from 18-gauge steel. The formed outer edge
also assures a straight and level surface.

www.titus-hvac.com | www.titus-energysolutions.com

VAV Diffusers
T3SQ-4

T3SQ-4 - Border Type 3


Ceiling Module A
Nominal Round Duct Size B
B minus

D
18

Ceiling Module A minus

24

Nominal Round
Duct Sizes B

Ceiling
Module A

Face Size

Nominal Round
Duct Size

Border Type

24 x 24

24 x 24

6, 8, 10, 12

1, 2, 3, 4, NT

10, 12

All dimensions are in inches.

T3SQ-4

Ceiling
Module A

L7

VAV Diffusers

T3SQ-2
DIGITAL - T3SQ-2
Configurations:
T3SQ-2

Heating/cooling

T3SQ-2

www.titus-hvac.com | www.titus-energysolutions.com

VAV Diffusers (continued)

The T3SQ-2 is an electronic variable volume


diffuser. The diffuser maintains space temperature
by varying the volume of air delivered to the
space. The amount of air delivered will depend
on the Supply Air Temperature (SAT), the room
temperature setpoint, and the room temperature.
As the volume of air is decreased by the control disc,
the velocity of air is increased, thereby maintaining
the longest throw and best entrainment. This insures
superior air distribution at all damper positions.
The curvature of the backpan works with the
formed edges of the face panel to deliver a tight
horizontal air pattern, without excessive noise or
pressure drop over the full range of operation.

T3SQ-2 master diffusers are created by connecting


the diffuser to a wall mounted controller/
thermostat using the RJ-12 control cable.
T3SQ-2 drone diffusers are created by
connecting the diffuser to a master unit
using the 4-pin mini-fit control cable.
Up to fifteen T3SQ-2 diffusers can be
powered by a single power module using
the 4-pin mini-fit power cable.
The position of the control disc is varied by a linear
drive actuator mounted on the control disc.
Standard finish is #26 White.
The face panel and backpan are constructed from
18-gauge steel. The formed outer edge also
assures a straight and level surface.

T3SQ-2

T3SQ-2 Border Type 3

Ceiling
Module A
24

L8

Nominal Round
Duct Sizes B
6
8
10, 12

1
1
1

3
3
3

Ceiling
Module A
24 x 24

All dimensions are in inches.

Face Size
24 x 24

Nominal Round
Duct Size
6, 8, 10, 12

Border Type
1, 2, 3, 4, NT

VAV Diffusers

ACCESSORIES

www.titus-hvac.com | www.titus-energysolutions.com

MASTER COMMUNICATION MODULE


Available with Standard (Titus)
communication module, BACnet,
or Lonworks gateway
MCM Is the central data collection
and distribution point for up to 60
VAV field diffusers per module.
Features four diffuser channel
inputs which can accommodate up
to 15 diffusers per channel, per
communication module (MCM).
Interface software is designed
as a commissioning tool as
well as for data monitoring,
logging, and fault finding.
Software is supplied with
each shipment.

CONTROLLER/THERMOSTAT

Each master T3SQ-2 diffuser


requires a controller / thermostat.
24VAC RJ-12 control
cable connection.
Room sensor with LCD display
real time clock for night set-back
& control disc position display.
Provides Setpoint Temperature
adjustment & room temp display.
Interfaces with a USB module in
order to interface with software
for further functionality.
Dimensions are 3 x 3

LCD SCREEN

UP

FUNCTION

DOWN

ENTER / ACCEPT

OPTIONAL INLET ELECTRIC HEATER

Installs into neck of diffuser.


120V, 208V or 277V single phase
input power (field connect).
Black heat element.
SCR modulating heater control.
Ships loose for field installation.
Integrated wiring interface box.
Automatic reset thermal cutout.
Manual reset secondary protection.

CABLES (HEATER CONNECTION)

RELIEF RINGS

Used to bypass supply air


into the ceiling plenum as
the diffuser turns down.
Available for both digital and
thermal configurations.
Effectively reduces inlet
size by 2 inches.

Nominal Duct Size B


minus

Available kW:
Inlet
Size
6
8
10
12

120V
0.75
1.00
1.25
1.25

Voltage
FLA
208V 277V 120V 208V 277V
0.75 0.75 6.3
3.6
2.7
1.00 1.00 8.3
4.8
3.6
1.50 1.50 10.4 7.2
5.4
2.00 2.00 10.4 9.6
7.2

2
4

Field connect
line voltage

ACCESSORIES

Blue RJ-45 (8-pin straight through


pinout) for control and power.
Modular connector that attaches the
ribbon cable and RJ45 to heater.

24V output

L9

VAV Diffusers

T3SQ-0
NON-VAV - T3SQ-0
Configurations:
T3SQ-0

Supply/Return

T3SQ-0

www.titus-hvac.com | www.titus-energysolutions.com

VAV Diffusers (continued)

The T3SQ-0 is a non-VAV supply or return diffuser with


a center induction cap designed to match the T3SQ-4
thermal VAV diffusers.
The curvature of the backpan works with the
formed edges of the face panel to deliver a tight
horizontal air pattern, without excessive noise or
pressure drop over the full range of operation.
The T3SQ diffuser is designed to satisfy
architectural, as well as engineering criteria. The
strong, clean, unobtrusive lines harmonize with
the ceiling, without sacrificing performance.

The standard finish is #26 White.


The face panel and backpan are constructed
from 18-gauge steel. The formed outer edge
also assures a straight and level surface.

T3SQ-0 Border Type 3


Ceiling Module A
Nominal Round Duct Size B
B minus

18

Ceiling Module A minus

Ceiling
Module A

1
1
1

3
3
3

Ceiling
Module A
24 x 24

T3SQ-0

24

Nominal Round
Duct Sizes B
6
8
10, 12

L10

All dimensions are in inches.

Face Size
24 x 24

Nominal Round
Duct Size
6, 8, 10, 12

Border Type
1, 2, 3, 4, NT

VAV Diffusers

VAV Diffusers (continued)

Border Type 1 Rapid Mount Frame (for surface mounting


applications)

Clip is adjustable
up and down to fit
varying ceiling
thickness

The T3SQ series of diffusers is not available with standard


Border Type 1. For surface mounting applications, the
TRM optional Rapid Mount Frame can be used. Using
border option TRM, the T3SQ diffusers are shipped
with Border Type 3 (lay-in). The TRM frame is shipped
separately for field installation. Once the TRM is installed,
the T3SQ diffuser simply lays into the frame. This option
allows access into the ceiling after installation.

Border Type 2 (Snap-In)

" to 7/8"
3

/16"

11/8"

24"

24"

Border Type 4 (Spline)


Ceiling Module A

Ceiling Module A

13

Mounting
hardware
by others

/8"

/8"

/16"

www.titus-hvac.com | www.titus-energysolutions.com

BORDER TYPES

Border Type NT

233/8"

17/8"
5

/16"
9

/16"
Easy three step hook installation for the face plaque

Installation is completed by lining up the hooks on


the face plaque assembly with the corresponding
slot.

1.

All dimensions are in inches.

2.

BORDERS

Face Plaque Installation

3.

L11

VAV Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

T3SQ MAXIMUM FLOW SELECTION


Inlet Size

10

12

Neck Velocity
Velocity Pressure
Static pressure
Total Pressure
cfm
NC
Throw, ft
Static pressure
Total Pressure
cfm
NC
Throw, ft
Static pressure
Total Pressure
cfm
NC
Throw, ft
Static pressure
Total Pressure
cfm
NC
Throw, ft

400
0.010
0.016
0.026
79
5
1-2-3
0.021
0.031
140
8
2-3-5
0.030
0.040
218
14
3-4-8
0.048
0.058
314
24
4-6-11

500
0.016
0.024
0.040
98
10
1-2-4
0.032
0.048
175
13
2-3-7
0.047
0.063
273
19
4-5-10
0.075
0.091
393
29
5-8-12

T3SQ AHRI RATING


Inlet Size

Hz Octave Band Center Frequency

Minimum
Differential
Static Pressure,
in H20
Max. Inlet Static
Pressure,
in H2O

Standard Airflow Standard Airflow


Throttled Damper Fully open damper
400 fpm Neck
750 fpm Neck
Velocity
Velocity

Discharge
Discharge

Standard Ratings Sound Power Level, dB

AHRI Rating Data


3. Airflow, cfm
4. Min. Operating Pressure, in H20
5. Max. Inlet Static Pressure
@ 400 fpm Neck Velocity, in H20
6. Rated with Pressure Relief, yes/no

PERFORMANCE DATA

600
700
800
900
1000
0.022 0.031
0.040
0.050
0.062
0.037 0.048
0.064
0.082
0.100
0.059 0.079
0.104
0.132
0.162
118
137
157
177
196
14
17
20
23
25
2-3-5
2-3-6
2-3-7
3-4-7
3-4-8
0.047 0.063
0.083
0.106
0.130
0.069 0.094
0.123
0.156
0.192
209
244
279
314
349
17
20
23
25
28
2-4-8
3-5-9
3-5-10 4-6-10
4-7-11
0.069 0.093
0.122
0.155
0.190
0.091 0.124
0.162
0.205
0.252
327
382
436
491
545
23
26
29
31
34
4-6-11 5-8-12 6-9-13 6-10-14 7-10-14
0.109 0.147
0.192
0.244
0.301
0.131 0.178
0.232
0.294
0.363
471
550
628
707
785
33
36
39
41
44
6-9-13 7-10-14 8-11-15 9-11-16 10-12-17

125
250
500
1000
2000
4000
125
250
500
1000
2000
4000

6 Inlet
147
0.091

8 Inlet
262
0.108

10 Inlet
409
0.142

12 Inlet
589
0.204

0.116

0.196

0.392

0.565

n
36
37
34
30
21
+
+
36
40
34
23
+

n
38
40
36
34
29
19
44
52
57
51
44
37

n
46
48
42
39
32
23
46
54
58
55
48
42

n
53
56
50
44
36
28
50
55
60
58
52
47

2000
19

4000
17

Note: Sound Power levels below values shown in this table shall be listed as below significance.
Use a plus sign (+) to indicate below significance.
Hz Octave Band
Sound Power Level, dB

125
36

250
29

500
26

1000
22

Performance data is presented for the T3SQ diffuser with the internal VAV damper in full open position.

L12

VAV Diffusers

PERFORMANCE DATA

The performance of the T3SQ diffuser is related to supply


static pressure and size. If the supply static pressure is held
at a constant value and the VAV diffuser damper is throttled
to a closed position, the airflow pattern is changed from a
square pattern to a star pattern. The isovel in the adjacent
illustration demonstrates this pattern change. With the

reduction of cfm, throw does not decrease as in standard


diffusers. As the damper closes the discharge velocity is
slightly increased, minimizing throw reduction. With a fixed
inlet pressure, the sound values have very small changes of
intensity as the damper is modulated.

Airflow Pattern Changes


Minimum
Position

www.titus-hvac.com | www.titus-energysolutions.com

AIR DISTRIBUTION AT VARIOUS


DAMPER POSITIONS

50% Open

Sensor

Fully Open

Note: The isovel changes as the diffuser damper modulates from open to close
(or any combination between) causing variations to the ariflow pattern.

PERFORMANCE DATA
L13

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

Available Models:
T3SQ-4
T3SQ-2

Thermal
Digital

T3SQ-4 HEATING / COOLING THERMALLY POWERED VAV


DIFFUSER
Furnish and install Titus model T3SQ thermally powered VAV
diffusers with heating / cooling changeover.
Each diffuser shall be thermally powered to infinitely vary
the supply of air into the space, in either heating or cooling
mode, by means of regulating a variable aperture damper,
known as a control disc, vertically within the diffuser. Supply
air from the variable geometry diffusers will discharge
horizontally in a 360 pattern and will maintain constant
air movement in the space throughout the range of volume
variation from 100% down to 25%.
The thermal room sensing element shall be located behind
an induction cap in the center of the diffuser panel and
shall provide no more than 1F thermal deadband between
induced temperature and zone temperature.

SPECIFICATIONS

Each diffuser shall be individually adjustable to sense room


temperature within the space between 68F and 77F.
Each diffuser shall be individually adjustable for minimum
airflow from 0 to 30%. Each diffuser is to be fitted with a
single thermal supply air sensing element to automatically
change from and to a cooling and heating mode and be able
to infinitely vary the supply of air into the space in either
mode. Each diffuser shall be self-contained and require
no external power source to maintain space temperature
throughout the range of operation. The T3SQ-4 thermal
diffusers shall carry the manufacturers 10-year warranty.

L14

Ceiling diffusers shall be square, architectural, panel face


diffusers. The diffuser shall have an 18-gauge steel face
panel mounted on an aerodynamically shaped, one piece,
seamless back pan. The diffuser face panel must be field
removable by means of four positive locking clips. The
exposed surface of the face panel shall be smooth, flat and
free of visible fasteners. The face panel cannot project more
than -inch below the outside border of the diffuser back
pan.
The face panel shall have an aerodynamically shaped,
hemmed edge. A single metal thickness on the edges of
the face panel is not acceptable. Ceiling diffusers with a 24
x 24-inch full face shall have no less than an 18 x 18-inch
face panel. The entire diffuser shall be constructed of steel,
with an integral drawn inlet. The diffuser neck shall have a
minimum 1-inch depth available for duct connection.

VAV Diffusers
Finish shall be a thermoset alky-melamine enamel paint,
baked at 315F. The paint hardness must be 2H to 3H.
The paint must pass a 300-hour ASTM D1654 Corrosive
Environments Salt Spray Test without creepage, blistering
or deterioration of film. The paint must pass the 500-hour
ASTM D870 Water Immersion Test. The paint must also pass
the ASTM D2794 Reverse Impact Cracking Test with 50-inch
pound applied.
Alternatives to the specified product must provide published
performance ratings that meet or exceed the performance
of the T3SQ ceiling diffuser. All test data shall be obtained
in accordance with ANSI/ASHRAE Standard 702006 and
AHRI Standard 880. A copy of the certified test results shall
be provided upon request. The VAV diffuser shall be AHRI
certified.

T3SQ-2 DIGITAL ELECTRONIC VAV DIFFUSER WITH


HEATING/COOLING CHANGEOVER
Furnish and install Titus model T3SQ digital electronic VAV
diffusers. Each diffuser shall be electronically controlled by
a 24VAC actuator to infinitely vary the supply of cold air
into the space by means of regulating a variable aperture
damper, known as a control disc, vertically within the
diffuser. Supply air from the variable geometry diffusers will
discharge horizontally in a 360 pattern and will maintain
constant air movement in the space throughout the range of
volume variation from 100% down to 25%.
The room sensing element shall be located in the master
controller/thermostat unit. Each diffuser shall be adjustable
to sense room temperature within the space between 65F
and 80F. In large zones, up to 14 drone units connected
to a master unit can be used. Each diffuser shall have an
electronic wiring interface having RJ-12 sockets for easy
interfacing with master controller/thermostat and 4-pin
connection for adjacent parallel master and drone diffusers.
Each diffuser shall have a changeover sensor to determine
supply air temperature and change the diffuser from heating
to cooling operation.
The Master Communications Module is a central data
collection and distribution point for up to 60 VAV diffusers.
The device features four diffuser channel inputs, which
can accommodate up to 15 diffusers each. Communication
on these channels is by means of a Lin bus interface to
four field Power Supply units connected by dedicated
communication cables.
This centralized data is monitored on a PC running the MLM
software Application via an Ethernet TCP/IP interface. The
MLM software Application is designed as a commissioning

SUGGESTED SPECIFICATIONS

In addition to the collection and distribution between field


diffusers and the MLM Application, the unit also features an
on-board web server. This web server can be accessed by
a standard browser tool and is used to setup IP addresses,
Device identification data as well as communications
parameters. In general the web server is used on initial
installation to bind to the IP network and to uniquely
identify the product, normally by physical location.
A serial USB port provides limited diagnostic capability. In
general it is used in production to set MAC, IP and port
addresses. It can be used to verify and set port and IP
addresses.
A LON compatible gateway is achieved by adding a plugin hardware module to the MCU. This hardware module
contains a subset of the ANSI/CEA-709.1-B (EN14908.1)
protocol stack and interface via a TP/FT-10 (Free topology)
transceiver network to the device bus. The functional block
implementation is indicated in LHA DOC BQ0254-A. Up to
20 of these functional blocks can be selected for a client
interface to 20 master control zones. Again the user has
the option to use the MLM Application for diffuser setup
and diagnostics and the Lon client for general control
supervision.
One ETL rated power module, model T3PM shall be
required for every 15 T3SQ-2 diffusers with or without
optional electric heaters. The power module shall have a
optional 120V, 208V, 240V, 277V/24VAC transformer and
a power filter to provide clean 24VAC to the diffusers. All
connections, except line voltage to the power module or
optional inlet electric heater, shall be made using plug-n-play
4-pin minifit connector cables.
Optional ETL listed inlet incoloy black heat sheathed
electric heater shall install into the inlet of the diffuser
and be protected by two automatic thermal cutouts and

an airflow proving switch. Inlet electric heaters shall be


controlled proportionally by means of triac heater controllers
(SCR), each having an electronic wiring interface having
three RJ-45 and 2 RJ-12 sockets for easy interfacing with
master controller/thermostat and/or adjacent parallel master
and drone diffusers. The inlet electric heater shall have a
2F proportional band and be energized at 1F below room
temperature set point. Ceiling diffusers shall be square,
architectural, panel face diffusers. The diffuser shall have an
18-gauge steel face panel mounted on an aerodynamically
shaped, one piece, seamless backpan. The diffuser face
panel must be field removable by means of four positive
locking clips. The exposed surface of the face panel shall
be smooth, flat and free of visible fasteners. The face panel
cannot project more than -inch below the outside border
of the diffuser backpan.
The face panel shall have an aerodynamically shaped,
hemmed edge. A single metal thickness on the edges of
the face panel is not acceptable. Ceiling diffusers with a 24
x 24-inch full face shall have no less than an 18 x 18-inch
face panel. The entire diffuser shall be constructed of steel,
with an integral drawn inlet. The diffuser neck shall have a
minimum 1-inch depth available for duct connection.

www.titus-hvac.com | www.titus-energysolutions.com

tool as well as for data monitoring, logging and fault finding


which is supplied by Titus.

VAV Diffusers

Finish shall be a thermoset alky-melamine enamel paint,


baked at 315F. The paint hardness must be 2H to 3H.
The paint must pass a 300-hour ASTM D1654 Corrosive
Environments Salt Spray Test without creepage, blistering,
or deterioration of film. The paint must pass the 500-hour
ASTM D870 Water Immersion Test. The paint must also pass
the ASTM D2794 Reverse Impact Cracking Test with
50-inch pound applied.
Alternatives to the specified product must provide published
performance ratings that meet or exceed the performance
of the T3SQ ceiling diffuser. All test data shall be obtained
in accordance with ANSI/ASHRAE Standard 702006 and
AHRI Standard 880. A copy of the certified test results shall
be provided upon request. The VAV diffuser shall be AHRI
certified.

SPECIFICATIONS
L15

VAV Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

SPECIFICATIONS

L16

MODEL NUMBER SPECIFICATION

Neck Size
6
8
10
12

Model
T3SQ

X
0
2
4

Border Type
2
3
4
5
NT
X

Non-VAV supply/return
Digital
Thermal (heating & cooling)

Configuration

X
26 White
Finish

critical environment diffusers

R
www.titus-hvac.com | www.titus-energysolutions.com

www.titus-hvac.com | www.titus-energysolutions.com

Table of Contents

Critical Environment Diffusers

critical environment products


Critical Environment Products........................................................................................................................................................R4

overview
Applications....................................................................................................................................................................................R6
General Clean Room Information............................................................................................................................................R6
Air Motion...............................................................................................................................................................................R6
Air Volume .............................................................................................................................................................................R7
Air Filtration and Quality Control ...........................................................................................................................................R8
Proper Equipment ..................................................................................................................................................................R8
Personnel Training..................................................................................................................................................................R8

radial pattern
VersaTec..........................................................................................................................................................................................R9
Overview.................................................................................................................................................................................R9
Dimensions...........................................................................................................................................................................R10
Performance Data.................................................................................................................................................................R11
Suggested Specifications......................................................................................................................................................R12
Model Number Specification................................................................................................................................................R12
TriTec.............................................................................................................................................................................................R13
Overview...............................................................................................................................................................................R14
Dimensions...........................................................................................................................................................................R14
Performance Data.................................................................................................................................................................R15
Suggested Specifications......................................................................................................................................................R16
Model Number Specification................................................................................................................................................R16
RadiaTec ......................................................................................................................................................................................R17
Overview...............................................................................................................................................................................R17
Dimensions - Without HEPA Filter Rack...............................................................................................................................R18
Dimensions - With HEPA Filter Rack....................................................................................................................................R19
Performance Data.................................................................................................................................................................R20
Suggested Specifications......................................................................................................................................................R21
Model Number Specification................................................................................................................................................R21

CRITICAL ENVIRONMENT

laminar pattern

R2

TLF................................................................................................................................................................................................R22
Overview...............................................................................................................................................................................R23
HEPA Filter Option................................................................................................................................................................R23
Performance Data.................................................................................................................................................................R24
Suggested Specifications......................................................................................................................................................R25
Model Number Specification................................................................................................................................................R25

linear air curtain


LineaTec........................................................................................................................................................................................R26
Overview...............................................................................................................................................................................R26
Dimensions ..........................................................................................................................................................................R27
Performance Data.................................................................................................................................................................R29
Suggested Specifications......................................................................................................................................................R30
Model Number Specification................................................................................................................................................R30
SteriTec.........................................................................................................................................................................................R31
Overview...............................................................................................................................................................................R32
Dimensions ..........................................................................................................................................................................R33
Linear Plenum Details...........................................................................................................................................................R34

Table of Contents (continued)

Critical Environment Diffusers

fan filter diffusers


Fan Filter Diffusers.......................................................................................................................................................................R38
Dimensions...........................................................................................................................................................................R39
Options & Accessories..........................................................................................................................................................R43
Performance Data.................................................................................................................................................................R44
Suggested Specifications......................................................................................................................................................R45
Model Number Specification................................................................................................................................................R45

accessories
Accessories...................................................................................................................................................................................R46
HEPALERT.............................................................................................................................................................................R46
HEPA Filter ...........................................................................................................................................................................R47

application notes
Application Notes.........................................................................................................................................................................R49
Titus Operating Room Air Distribution System.....................................................................................................................R49
System Sizing & Layout........................................................................................................................................................R49
Operating Room Air Distribution System..............................................................................................................................R50

www.titus-hvac.com | www.titus-energysolutions.com

Flange and Hanger Bracket Details.......................................................................................................................................R35


Plenum Inlet Locations.........................................................................................................................................................R36
Suggested Specifications......................................................................................................................................................R37
Model Number Specification................................................................................................................................................R37

cleanroom terminology
Basic Cleanroom Terminology......................................................................................................................................................R51

CRITICAL ENVIRONMENT
R3

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

Critical Environment Products

RADIAL PATTERN

pages: R9-R21

RadiaTec-AL / RadiaTec-SS

TriTec / TriTec-AL / TriTec -SS

VersaTec / VersaTec-AL

RADIAL PATTERN DIFFUSER

RADIAL PATTERN DIFFUSER

RADIAL PATTERN DIFFUSER

Designed for cleanroom applications.


Delivers high volumes of air at low velocity.
Fixed radial discharge pattern with 1-way or
2-way option.
Optional HEPA filter rack available .

D esigned for cleanroom applications.


Delivers high volumes of air at low velocity.
Fixed radial discharge pattern with 1-way or
2-way option.

D esigned for cleanroom applications.


Delivers high volumes of air at low velocity.
Radial discharge pattern is adjustable using
face mounted louvers.

LAMINAR PATTERN

CRITICAL ENVIRONMENT

pages: R22-R25

R4

TLF / TLF-AA / TLF-SS


LAMINAR PATTERN DIFFUSER




I ndustry standard for unidirectional airflow diffuser.


For use in clean air environments such as operating rooms.
Laminar flow pattern minimizes induction and entrainment of room air.
Steel, aluminum or stainless steel construction.
Optional HEPA filter rack available.

Critical Environment Diffusers

Critical Environment Products (continued)

LineaTec-AL / LineaTec-SS

SteriTec-AL / SteriTec-SS

LINEAR AIR CURTAIN DIFFUSER

STERILE ENVIRONMENT SYSTEM

SteriTec system combines the TLF and LineaTec diffusers to form a clean zone
within a clean room.
Corner transitions are full plenum size creating no airflow restriction.
Continuous plenums minimize duct runs.
Aluminum or stainless steel construction.
Optional HEPA filter rack available on TLF diffusers.

For use in clean air environments like operating rooms.


Creates air curtain barrier between clean zone and balance of room.
Optional plenums available with square or round corners.
Aluminum or stainless steel construction.

www.titus-hvac.com | www.titus-energysolutions.com

LINEAR AIR CURTAIN

pages: R26-R37

FAN FILTER DIFFUSERS

pages: R38-R45

FFDE

FFDER

FFDR

FAN FILTER DIFFUSERS

FAN FILTER DIFFUSERS

FAN FILTER DIFFUSERS

FAN FILTER DIFFUSERS

Unique solution for cleanroom


environments.
PSC motor.
Solid state speed control.
Low profile design.

Unique solution for cleanroom


environments.
ECM motor.
Digital speed control.
Low profile design.

U nique solution for cleanroom


environments.
PSC motor.
Solid state speed control.
Roomside replaceable HEPA filter.
Low profile design.

U nique solution for cleanroom


environments.
ECM motor.
Digital speed control.
Roomside replaceable HEPA filter.
Low profile design.

CRITICAL ENVIRONMENT

FFD

R5

www.titus-hvac.com | www.titus-energysolutions.com

Overview

CRITICAL ENVIRONMENT

R6

APPLICATIONS
Titus representatives have installed diffusers in cleanrooms
and in clean areas throughout the entire country for over 25
years. Many operating rooms and research laboratories as
well as numerous other facilities have Titus environmental
diffusers.
Clean rooms include hospital operating rooms, electronics
manufacturing, pharmaceutical and biotechnology
manufacturing, research facilities, automotive painting and
many other applications.

GENERAL CLEANROOM INFORMATION


Design criteria for clean rooms include cleanliness
classification desired, air volume requirements, air motion,
proper filtration and removal of contaminants, properly
designed equipment and personnel training. Titus
products are designed to help the engineer with the proper
air distribution requirements and air motion.

Critical Environment Diffusers


Contamination comes from two sources: external and
internal. External sources include incoming air, wall
penetrations for pipes, ducts and other HVAC equipment.
Internal sources include personnel, process equipment,
manufacturing processes and material ingress.
No matter what source has contributed to the unwanted
particle count, the design of the clean room or clean area
facilitates the control of incoming particles and eliminates
particles within the environmental envelope.

AIR MOTION
Motion is critical to control concentrations of particles in
the entire clean room or in a particular area of the room.
Air motion is either unidirectional, also called laminar, or
multi-directional. The following figure shows typical clean
room airflow patterns. Unidirectional air motion is used to
push unwanted particles out of the controlled space. Multidirectional air motion can be used to remove unwanted
particles by dilution.

APPLICATIONS

Unidirectional

Multi-directional

Laminar flow can be used to provide clean airflow over an


obstruction and push particles to a floor return plenum.
Return grilles can be located in the floor of the room and
can be exhausted as shown in the figure, Laminar Flow.
In many cases, however, codes require the return air grille
to be mounted in the lower side-wall of the room. This
allows the floors to be mopped and cleaned for standard
conditions. For Class B and C operating rooms, the return
grilles should be mounted with their lower frame at least 8
inches above the floor in the far corners of the room.
In many clean rooms work areas are designed with laminar
flow. Fume hoods may obtain supply air from directly inside
the room immediately adjacent to the fume hood while
exhausting the air externally. The maximum allowable
air velocity in front of fume hoods must be less than the
capture velocity of the hood. This room velocity is generally
about 15 to 35 fpm, helping to ensure the air within the
fume hood is not induced out of the hood and into the
room. Proper location of air devices helps further reduce
unwanted air motion. The placement of the diffuser can be
critical and care should be taken to avoid entrainment of
fumes from hoods into the laboratory. Special short throw
diffusers can be used in these locations to eliminate high
velocities from moving across the face of the hoods as
shown in the photograph in the proceeding page. Typical
hood capture velocities are about 100 fpm.
Whether unidirectional or multi-directional airflow patterns
are utilized, air velocities in the clean area must be
controlled. Particles 0.5 micrometers and larger tend to
quickly settle on the floor or other work surfaces due to
gravity. These particles are easily disturbed and re-entrained
into the clean room atmosphere, thereby recontaminating
a previously clean area. To control re-entrainment, air
velocities at the floor area should be below 50 fpm.

www.titus-hvac.com | www.titus-energysolutions.com

When using multi-directional air motion the designer


is depending solely on dilution to achieve the desired
cleanliness level. Although dilution may reduce particle
levels in the entire room to a moderate average level,
it does not ensure that any given area in the room is
controlled to acceptable particulate levels.

Critical Environment Diffusers

Typical Airflow Patterns in Clean Room

R
Diffuser
Obstruction

Clean Area
Particle

Raised
Perforated
Floor
Return
Plenum

Laminar Flow (Class 1 - 1000)

AIR VOLUME

APPLICATIONS

Air volume is a key to creating and sustaining any given


class of a clean room. Large volumes of clean air are used
to dilute contaminated air. In other words, contaminated air
is slowly displaced by clean, treated air. As more clean air
is brought into the room and contaminated air is removed
from the room, the clean air dilutes the contaminated air.
This process slowly reduces the particle level in the room.
Volume is determined by the job engineer according to
standard industry practices, experience, and situational
requirements. It is common to specify 10 to 40 air changes
per hour in a critical environment. Class 1 to 100 clean
rooms may have air change rates as high as 300 to 600 air
changes per hour.

R7

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATIONS
Filter Designation and Efficiency Level

Name

Designation

Efficiency

Max Particle
Size

High-Efficiency
Filter

HE

95%

0.3

High-Efficiency
Particulate Filter

HEPA

99.90%

0.3

Ultra-Low
Penetration
Air Filter

ULPA

99.9995%

0.12

AIR FILTRATION AND QUALITY CONTROL

All clean rooms utilize filtration systems to purify incoming


air and/or recirculated air. These systems usually include
prefilters that are low cost and easily replaceable. Prefilters
are the first step in extracting or trapping unwanted
particles from the air.
Upstream of the high-efficiency particulate (HEPA) or
ultra-low penetration (ULPA) air filters, prefilters of 30
percent and then 85 percent greatly reduce the amount
of contaminants that need to be eliminated by HEPA or
ULPA filters. The chart on this page classifies commonly
designated filters and their efficiencies.
For clean room classes 1,000 to 100,000, regardless of the
filter classification specified, several principles should be
considered prior to application. The best place for
high-efficiency filters is upstream of the air outlets in a
remote location. If the high-efficiency filter is an integral
part of the air distribution device, removal of the filter
should be accomplished from outside the protected zone.
Working with the filter in the protected zone creates a high
probability of contaminating the clean zone.

APPLICATIONS

Volume control dampers should be located upstream of the


high-efficiency filter so that operation of the damper does
not contaminate the airstream.
Chemical filtration may also be included. The filter media is
typically activated carbon.
Air quality includes temperature and humidity control.
Elaborate systems have been developed by the industry to
control these two factors. Humidity is typically controlled
somewhere around 50%. Temperature control specifications
may be within 1 F or less.
Pressurization of the clean room or clean zone also
contributes to air quality. Higher pressure clean
zones help reduce infiltration of contaminants from outside

R8

sources. The typical room differential pressure specified


is 0.05 inch wg according to Federal Standard 209B. Most
critical environmental rooms have positive pressurization to
keep contamination out of these areas.

PROPER EQUIPMENT
Equipment and construction materials may emit
contamination. Equipment utilized in clean rooms is typically
304 stainless steel. Internal construction is engineered
to retard outflow of contaminants from sources such as
bearings, plastics and other decaying material or
moving parts.
Air showers or tunnels may be provided for personnel
entering the controlled zone. Air curtains may be used to
also protect the clean zone.
Cleaning equipment such as high efficiency vacuum
cleaners, tack cloths, lint-free cleaning cloths and autoclaves
all contribute to the overall cleanliness of the room or area.

PERSONNEL TRAINING
Proper clean room etiquette is critical to maintaining a clean
environment. Protocol for entering the room and leaving the
room must be maintained. Movement within the room must
be controlled. Sudden movements by personnel can entrain
settled contaminated particles back into the clean airstream.
Titus has a complete line of diffusers designed for
applications requiring unidirectional or multi-directional
airflow. Laboratories, operating rooms, electronics
manufacturing, pharmaceutical and biotechnology
manufacturing, automotive painting and many other
applications can benefit from using Titus Critical
Environment Diffusers.

Critical Environment Diffusers

HEMISPHERICAL AIR DIFFUSION USING ADJUSTABLE BLADES


Steel Backpan with
Aluminum Blades.
Aluminum Backpan
and Blades.

VersaTec


Available Models:

VersaTec



VersaTec-AL

Finish
Standard Finish - #26 White
Optional Finish - #04 Mill

24 x 24-inch has 10-inch inlet


48 x 24-inch has 12-inch inlet.

Uses specially formed adjustable blades for maximum


free area and directional throw.

Perforated or louvered center section.

High airflow capacity (200 to 1,000 cfm).


Available in 24 x 24-inch or 48 x 24-inch module sizes.

Available for laying into standard T-bar ceiling grids.


Surface mounted units are laid into a Titus TRM frame.
Internal air baffling to equalize airflow across the face
of the diffuser.

Individually adjustable louvers.

www.titus-hvac.com | www.titus-energysolutions.com

Radial Pattern
VersaTec

Backpan not visible from below.

Louvers direct airflow slightly below ceiling level.

These diffusers are an excellent choice for Class


1,000 to 100,000 rooms. Applications include clean
room environments such as labs with exhaust hoods,
pharmaceutical manufacturing and biotechnology
research.

VERTICAL THROW

VersaTec models feature adjustable pattern


control technology for delivering high volumes of
low velocity air in a radial pattern. Each model is
constructed using adjustable blades which allow
adjustment of the discharge air pattern. Two
versions of this model are available; VersaTec with
an optional adjustable blade face and VersaTec with
a perforated center section. VersaTec diffuser blades
hang less than 1-inch below the ceiling.

VersaTec with adjustable blade face

HORIZONTAL
SETTING

VERTICAL
SETTING

HORIZONTAL THROW
(SPREAD)

HEMISPHERICAL
SETTING

VersaTec with perforated center section

HORIZONTAL/VERTICAL
SETTING

HORIZONTAL THROW
(SPREAD)

HEMISPHERICAL
SETTING

VERSATEC

VERTICAL THROW

OVERVIEW

R9

Critical Environment Diffusers

VersaTec with perforated center section


Inlet

/8"

Side View

Face View

End View
6"

Module minus "


3

/8"

D minus 1/8"

Module minus "

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS

2"

VersaTec with optional adjustable blade face


Inlet

Side View

"

End View

Face View
Module minus "

6"

R10

Module minus "

DIMENSIONS

"

D minus "

2"

Critical Environment Diffusers

PERFORMANCE DATA

48 x 24
12 Inlet
24 x 24
10 Inlet

cfm
NC
Total Pressure
Horizontal Throw
5 FT
Vertical Throw
Horizontal Throw
15 FT
Vertical Throw
cfm
NC
Total Pressure
Horizontal Throw
5 FT
Vertical Throw
Horizontal Throw
15 FT
Vertical Throw

400
23
0.05
1-2-4
1-2-3
1-2-3
1-3-5
200
21
0.02
1-1-1
1-1-2
1-1-1
1-1-3

Throws are to terminal velocities of 100, 50 and


25 fpm. See the section, Engineering Guidelines
and the topic Procedure to Obtain Catalog Throw
Data in this catalog for throw information.
The horizontal throw is the distance
of the overall width of the jet.
Use above performance data table for
optional curved blade center section.

Hemispherical
600
28
0.10
2-3-6
2-3-5
2-3-5
2-4-7
300
25
0.07
1-1-2
1-2-4
1-1-2
1-2-5

Discharge Pattern
800
30
0.18
3-4-7
2-4-7
3-3-6
2-4-8
400
27
0.14
1-2-3
2-3-5
1-1-2
2-4-6

400
26
0.05
3-4-7
1-3-4
3-4-5
1-3-6
200
22
0.04
2-4-6
2-3-6
2-3-5
2-3-8

Horizontal (Spread)
600
800
31
33
0.13
0.24
5-6-8
5-6-13
2-3-6
3-4-7
4-5-6
5-5-11
2-4-8
3-5-9
300
400
27
29
0.09
0.16
4-5-9
5-7-12
3-5-7
4-6-9
2-4-8
5-6-10
3-5-8
4-7-10

NC is the noise criteria curve that will not


be exceeded in octave bands 2 thru 7. The
NC assumes a 10 db room absorption.
Air patterns between the two shown in the
isovel diagrams on the previous page can be
obtained by adjustment of the blades.

www.titus-hvac.com | www.titus-energysolutions.com

VERSATEC AND VERSATEC-AL

PERFORMANCE DATA
R11

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS
VERSATEC, VERSATEC-AL

PERFORMANCE

Air diffusers marked _______ shall be Titus model number


VersaTec, VersaTec-AL. Diffusers shall be constructed using
a maximum 6 inches tall backpan designed for optimum
performance with the diffuser.

NC values representing the noise criteria curve shall be


published. Throw values for terminal velocities of 100, 50
and 25 fpm shall be published along with corresponding
pressure drop.

The backpan shall be provided with cross sectionalizing


baffles to evenly distribute supply air. The diffuser face shall
have adjustable longitudinal extruded aluminum blades for
directional air control. The face shall hang below ceiling level
no more than 1 inches when the blades are in the full
open position. Blades shall be divided into three sets: righthand, left-hand and vertical projection.

Throws shall be published for both horizontal and vertical


air patterns. Performance tests shall have been conducted
in accordance with ASHRAE Standard 70-2006 and ASHRAE
Standard 113-2009.

The air pattern must be adjustable from a radial pattern to a


horizontal, vertical, or a combination of both horizontal and
vertical. Diffuser shall be available with optional 51 percent
free area perforated center section.

MODEL NUMBER SPECIFICATION

Model
VersaTec-AL
VersaTec
XXXXXXX-XX
Inlet Size

SPECIFICATIONS

48 x 24 Module 12
24 x 24 Module 10

R12

Module Size
24 x 24
48 x 24
XX
12
10

XX x XX

Rapid Mount
Frame

Blow Pattern
2-Way

Optional
TRM

White (std.)
Mill

XX
Face Style
Perforated Center
Straight Blade

XX
P
S

Finish
26
04
XX

Radial Pattern (continued)

Critical Environment Diffusers

HIGH VOLUME, LOW VELOCITY, RADIAL


AIR DIFFUSION TECHNOLOGY

Finish
Standard Finish - #26 White
Optional Finish - #04 Mill
Face drops no more than -inch
below the ceiling.
Removable face for sanitizing (no
special tool required to remove the
face).
Available in steel, 304 stainless
steel, or aluminum with 304
stainless steel face.
Available in 24 x 24-inch and 48 x
24-inch module sizes.
Chemistry Lab with TriTec Diffusers

TriTec Laboratory Application - End View

Low velocity hemispherical pattern


or one-way hemispherical pattern
available.

Simple to install and maintain.

Factory supplied back pan with


every unit.

Earthquake tabs supplied as


standard.

22-gauge backpan.

Retainer cable supplied with every


unit.

Available in inlet sizes of 8 or 10


inches for 24 x 24-inch module
sizes, 10 or 12 inches for 24 x 48inch module sizes.

Great for use in fume hood areas.

51 percent free area perforated


face matches industry standard
perforated diffusers appearance.

Standard unit lays into standard


T-bar ceiling grids. Optional TRM
mounting frame available for
surface mounting.

TriTec Laboratory Application - Side View

TriTec Laboratory Application - Plan View


24 INCHES
OR MORE

TRITEC

HORIZONTAL
SPREAD (FT)

Steel Face and Back


Pan
304 Stainless Steel
Face with Aluminum
Back Pan.
304 Stainless Steel
Face and Back Pan.

TriTec


Available Models:

TriTec


TriTec-AL



TriTec-SS

www.titus-hvac.com | www.titus-energysolutions.com

TriTec

R13

Critical Environment Diffusers

OVERVIEW
TriTec models are designed to allow
large volumes of air to be brought
into the environment with very short
throws.
Discharging air flow patterns of a
two-way blow provide a 180 degree
radial pattern, TriTec takes advantage
of the maximum space available for
distributing velocity. This results in
the lowest possible velocities for the
volume of air being delivered. Unlike
competitive models, TriTec takes
advantage of a 51 percent free area
perforated face that hangs below
the ceiling less than -inch. In
appearance, TriTec models look like
industry standard perforated diffusers.
TriTecs unique design allows it to
create a full pattern in the middle of
the diffuser as well as on the ends.
The design of the TriTec allows these
diffusers to be mounted end to end
without increasing the throw.

TriTec Layout
End View

Top View
Module size minus "

Earthquake Tabs
Pressure
Induction
Panel

Module Size minus "

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS

Pattern
Controllers
Velocity
Dampening
Chamber

D minus
"

Air
Dampening
Chamber

" to 11/16"

2"

Side View
Module Size

(Typ.)

6"
Safety Chain

TriTec Lay-In Application


Module Size

Back pan

Applications include labs with exhaust


hoods, pharmaceutical manufacturing,
telephone switching rooms,
biotechnology research and many
other applications where high airflows
with short throws are required. This
diffuser has a very high induction rate.
These diffusers are an excellent choice
for Classes 1,000 to 100,000 rooms.

T-Bar

15

/16"

Diffuser
Face

High induction diffusers, like the


TriTec should not be specified for Class
B or C operating rooms.
Surface Mount Application with Optional TRM Rapid Mount Frame

DIMENSIONS

DIMENSIONS
Air enters the diffuser and is spread
across the entire diffuser by the
pressure induction plate. As air passes
through the pressure induction plate
it expands into the air dampening
chamber. While passing through the air
dampening chamber, long fixed blades
direct the air creating a hemispherical
air pattern as the air passes through
the 51 percent free area face.

Module Size
Back pan
Clip is adjustable
up and down to fit
varying ceiling
thickness
B

1"
Diffuser
Face

R14

" to "
/16"

Critical Environment Diffusers

PERFORMANCE DATA

Module Size
and
Inlet Size
24 X 24
8 Inlet
24 X 24
10 Inlet
24 X 48
10 Inlet
24 X 48
12 Inlet
Module Size
and
Inlet Size
24 X 24
8 Inlet
24 X 24
10 Inlet
24 X 48
10 Inlet
24 X 48
12 Inlet

2-Way Pattern
cfm
Ps
Pt
250 0.055 0.087
300 0.080 0.126
400 0.142 0.224
500 0.222 0.350
250 0.026 0.039
300 0.037 0.056
475 0.093 0.140
600 0.148 0.224
375 0.054 0.084
500 0.097 0.149
700 0.190 0.292
900 0.313 0.483
500 0.054 0.080
650 0.092 0.135
750 0.122 0.179
1000 0.218 0.319

Nc
25
29
37
42
<20
20
31
37
<20
26
39
48
20
24
34
44

1-Way Pattern
Ps
Pt
0.055 0.087
0.094 0.148
0.142 0.224
0.179 0.283
0.025 0.038
0.049 0.075
0.081 0.123
0.121 0.184
0.092 0.144
0.143 0.225
0.206 0.324
0.297 0.467
0.051 0.076
0.086 0.129
0.114 0.171
0.203 0.304

NC
<20
29
35
38
<20
22
28
34
24
32
39
44
<20
25
31
42

cfm
250
325
400
450
250
350
450
550
500
625
750
900
500
650
750
1000

Horizontal Spread
(ft)
100-75-50
1
2
5
2
3
6
3
5
7
5
6
8
1
1
3
1
2
4
3
5
7
4
6
9
3
4
6
4
6
9
6
8
10
8
10
12
1
2
4
2
3
7
2
4
9
4
7
11
Horizontal Spread
(ft)
100-75-50
1
2
3
2
3
4
3
3
4
3
4
4
1
2
4
3
4
6
4
5
7
4
6
8
1
2
3
2
2
4
2
3
4
3
4
6
1
2
3
2
3
4
3
3
5
3
5
7

2-WAY PATTERN

0
0
1
1
1
1
2
3
1
2
2
4
2
4
5
7

5 Deg T
100-75-50
0
1
1
1
1
2
4
5
2
3
4
5
4
6
7
9

3
4
5
5
2
2
6
8
1
3
5
7
2
4
5
6

1
2
3
3
3
5
6
7
4
5
6
8
7
9
9
9

Vertical Throw (ft)


10 Deg T
100-75-50
1
2
3
1
2
4
2
4
5
3
5
7
0
1
2
1
1
3
2
3
6
3
5
8
1
1
2
1
2
4
2
4
6
3
5
8
1
1
3
1
2
5
2
3
6
3
5
8
Vertical Throw (ft)
10 Deg T
100-75-50
1
1
2
1
2
4
2
3
6
2
3
9
1
1
3
2
3
6
3
5
7
4
6
9
1
2
4
2
3
6
2
4
7
4
7
9
4
6
8
6
7
9
6
8
9
8
9
9

4
5
7
8
2
3
7
9
2
4
7
9
4
6
7
9

1
1
2
3
2
4
6
7
3
5
7
8
4
6
6
8

15 Deg T
100-75-50
1
2
4
5
3
6
8
9
6
8
9
9
6
7
8
9

3
5
8
9
7
9
9
9
9
9
9
9
8
9
9
9

Low emissivity heaters were used to maintain loads,


and were set to match the supply air conditions. The
room was free of obstructions during the tests.
Sound and pressure drop tests were conducted
in accordance with ASHRAE Standard 702006 and ANSI S1.31 Procedures.

1-WAY PATTERN
DIFFUSER

Diffuser

100, 75 or 50 fpm Isovel

VERTICAL
THROW (FT)

Vertical
Throw (ft)

1
2
3
4
1
1
2
3
1
1
2
3
1
2
2
4

15 Deg T
100-75-50
2
3
5
6
1
1
4
6
1
2
4
6
2
3
4
6

100, 75 OR
50FPM ISOVEL

PERFORMANCE DATA

Spread is the maximum width of the isovel


at the indicated terminal velocity.
Vertical throw is the furthest distance below the ceiling
where the indicated terminal velocity can be measured.
Tests were conducted in a 16 x 16-foot room, with
a 9-foot ceiling, low side wall returns, in accordance
with ASHRAE Standard 113-2009, in several planes.

1
1
3
3
0
1
1
2
0
1
1
2
1
1
1
2

5 Deg T
100-75-50
2
3
3
4
1
1
3
4
1
1
2
4
1
2
2
4

www.titus-hvac.com | www.titus-energysolutions.com

TRITEC, TRITEC-AL AND TRITEC-SS

Spread (ft)

HORIZONTAL
SPREAD (FT)

R15

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

TRITEC

Air diffusers marked _______ shall be Titus model number


TriTec. Diffusers shall be constructed using a maximum
6 inches tall backpan designed for optimum performance
with the diffuser. The backpan shall be divided into two
chambers: upper and lower. The backpan shall have integral
hanger tabs for securing the unit to the overhead structure.
The upper velocity dampening chamber shall be separated
from the lower air dampening chamber by a pressure
induction plate. All pattern controllers shall be internal to
the unit and shall be located in the lower air dampening
chamber.
The face of the diffuser shall be 51 percent free area
perforated steel with 3/16-inch diameter holes on -inch
staggered centers, and shall match the appearance of
industry standard perforated diffusers. The face shall not
hang below the ceiling more than inches and shall have 6
clips securing it in place.
The diffuser face shall have factory attached retainer cables.
The cables shall have removable clips to allow field cleaning
of all diffuser components.

PERFORMANCE

NC values shall be published. Throw for terminal velocities


of 100, 75 and 50 fpm shall be published along with
corresponding pressure drop. See the section, Engineering
Guidelines and the topic Procedure to Obtain Catalog Throw
Data for additional throw data.
Performance tests shall have been conducted in ASHRAE
Standard 70-2006 and ASHRAE Standard 113-2009.

TRITEC-AL

Use TriTec specification and make the following changes:


Change the model number to TriTec-AL.
Change the reference of steel to aluminum for the
backpan.
Change the reference of steel to 304 stainless steel for
the face.

TRITEC-SS

Use TriTec specification and make the following changes:


Change the model number to TriTec-SS.

Quarter-turn fasteners on the face are not acceptable. The


face, lower air chamber, directional blades, and the pressure
induction plate shall be one assembly that can be removed
from the face of the unit for sanitizing in an autoclave. The
face shall be provided with two retainer cables.

Change all reference of steel to 304 stainless steel.

The backpan shall be manufactured of 22-gauge steel. The


diffuser must be available for full radial air diffusion
(two-way) and/or radial air diffusion (one-way).

MODEL NUMBER SPECIFICATION


Model
TriTec

Module Size

TriTec-AL

24 x 48

TriTec-SS

24 x 24

XXXXXX-XX

XX

SPECIFICATIONS

Inlet Size

R16

(note)

8
10
12

XXxXX

White
(std.)
Mill

Finish
26
4
XX

TRM

Blow Pattern
8
10
12

1-Way
2-Way

1
2

Optional
Rapid Mount
Frame

Note: 8 and 10-inch inlets available with 24 x 24 module; 10 and 12-inch inlets
available with 24 x 48 module.

Critical Environment Diffusers

Radial Pattern (continued)

HIGH VOLUME LOW VELOCITY RADIAL


AIR DIFFUSION TECHNOLOGY
RadiaTec


Available Models:

RadiaTec-AL

RadiaTec-SS

Aluminum Face and Backpan.


304 Stainless Steel Face and Backpan.

Finish
Standard Finish - #26 White
Optional Finish - #04 Mill
Removable face for sanitizing from room-side (no
special tool required).
Available in aluminum and 304 stainless steel modular
parts, (face and back pan can be of a different
material).
Available in 24 x 24-inch and 48 x 24-inch module sizes
with one-way or two-way patterns.

Compatible with 1 or 1-inch T-bar ceiling grids.


Optional TRM mounting frame available for surface
mounting.
Optional HEPA Filter rack available.
(filter by Titus or others)

www.titus-hvac.com | www.titus-energysolutions.com

RadiaTec

Unique baffling inside diffuser assures even air


distribution across entire face.
Quarter-turn fasteners and retainer cables allow easy
access for cleaning and filter replacement.

Available inlet sizes: 8 or 10 inches for 24 x 24-inch; 10


or 12 inches for 48 x 24-inch modules.

OVERVIEW
The RadiaTec diffuser is designed to meet the challenge of
diluting airborne contaminants by supplying high-volume,
low-velocity airflow to displace these impurities. The airflow
pattern is designed to produce a uniform pattern to prevent
dead spots where contaminants can linger. In addition, the
air pattern is tighter to the ceiling than competitor models to
limit the air pattern penetration into the habitable zone.

RadiaTec in Laboratory Application - Side View

The RadiaTec creates a full pattern along the face of the


diffuser, and when mounted end-to-end, throw is not
increased.

VERTICAL
THROW
(FT)

Applications include labs with exhaust fans, pharmaceutical


manufacturing, biotechnology and other applications where
high air volume with short flow are required. The RadiaTecs
high induction rate draws impurities into its airstream,
allowing it to be diluted to less harmful levels prior to
exhausting the air. Excellent choice for Class 1,000 to
100,000 rooms.
RadiaTec in Laboratory Application End View

RadiaTec in Laboratory Application - Plan View

HORIZONTAL
SPREAD (FT)

VERTICAL
THROW
(FT)

HORIZONTAL
SPREAD
(FT)

RADIATEC

24 INCHES
OR MORE

R17

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS
Standard Model, No HEPA Filter Rack
Plenum

21
A

5
13
6

23

2-Way

Diffuser

21
A

Module minus 3

5
13
6

Module minus

23

1-Way

Module Size

Nominal Inlet Size

24 x 24

8
10
10
12

7
9
9
11

48 x 24

Border Detail Lay-in

Surface Mounting with TRM frame

DIMENSIONS

Security
Clip

R18

T-Bar
A

Ceiling
TRM
Frame

Tee
1
1

A
/8

Critical Environment Diffusers

DIMENSIONS

21

Plenum

8
16
6
Diffuser

23
2-Way

Module minus 3

21

8
16
6
Module minus

23

Module Size

Nominal Inlet Size

24 x 24

8
10
10
12

7
9
9
11

48 x 24

HEPA Filter Rack Knife Edge Dimensions

www.titus-hvac.com | www.titus-energysolutions.com

HEPA Filter Rack Model

1-Way

HEPA Filter Rack

HEPA Filter Gel Seal (by Others)


Interior Edge Sealed

DIMENSIONS

Module Size minus 6

HEPA Filter
Knife Edge
Wing Nut
Filter Holding Clip

R19

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

RADIATEC-AL AND RADIATEC-SS


Module Size
Inlet Size
24 x 24
8 Inlet
24 x 24
10 Inlet
48 x 24
10 Inlet
48 x 24
12 Inlet
Module Size
Inlet Size
24 x 24
8 Inlet
24 x 24
10 Inlet
48 x 24
10 Inlet
48 x 24
12 Inlet

2-Way Pattern
cfm
200
300
400
300
400
500
400
600
800
600
800
1000

Ps
Pt
NC
0.082 0.061 0.092 0.138 18
0.163 0.245 28
0.075 0.094 18
0.133 0.167 28
0.209 0.261 35
0.027 0.061 0.062 0.138 15
0.111 0.245 23
0.065 0.101 0.114 0.179 20
0.179 0.280 27
1-Way Pattern

cfm
200
300
400
300
400
500
400
600
800
600
800
1000

Ps
0.053
0.118
0.209
0.111
0.196
0.308
0.029
0.066
0.119
0.075
0.133
0.208

Pt
0.071
0.164
0.291
0.130
0.230
0.360
0.063
0.142
0.253
0.111
0.198
0.309

NC
12
25
34
26
35
41
16
26
23
31

Horizontal Spread (feet)


5 Degree T
15 Degree T
100 - 75 - 50
100 - 75 - 50
5
6
8
4
5
7
7
8
9
6
7
8
8
9
10
7
8
10
6
7
8
6
6
7
6
7
9
6
7
8
7
8
10
7
8
9
2
3
5
2
3
5
4
5
6
4
5
6
5
6
7
5
6
7
4
5
7
3
5
6
5
6
8
4
5
7
6
7
9
5
6
8
Horizontal Spread (feet)
5 Degree T
15 Degree T
100 - 75 - 50
100 - 75 - 50
5
6
7
5
6
7
6
7
8
6
7
9
7
8
9
7
8
10
5
6
7
5
6
8
6
7
8
6
7
9
7
8
10
7
8
10
3
5
7
3
5
8
5
6
8
6
7
9
7
8
9
7
8
10
4
6
8
5
6
7
7
8
9
6
7
8
8
9
11
7
8
9

Spread is the maximum width of the isovel


at the indicated terminal velocity.
Horizontal throw is the furthest distance from
diffuser center point where the indicated
terminal velocity can be measured.
Vertical throw is the furthest distance below the ceiling
where the indicated terminal velocity can be measured.

End View

End View

DIFFUSER

VERTICAL
THROW
(FT)

VERTICAL
THROW (FT)

PERFORMANCE DATA

Low emissivity heaters were used to


maintain loads, which were set to match
the supply air conditions. There were no
obstructions in the room during the tests.
Sound and pressure drop tests were conducted
in accordance with ASHRAE Standard 702006 and ANSI S1.31 Procedures.

1-WAY PATTERN

2-WAY PATTERN

HORIZONTAL
SPREAD
(FT)

R20

Vertical Throw (feet)


5 Degree T
15 Degree T
100 - 75 - 50
100 - 75 - 50
2
3
3
2
3
4
2
4
5
2
4
6
4
5
6
4
5
7
3
4
5
3
4
5
4
5
6
4
5
6
4
5
6
5
6
7
1
2
3
2
3
4
1
2
4
3
4
6
1
2
4
4
5
7
2
3
4
3
4
5
3
4
5
4
5
6
3
4
6
4
5
7
Vertical Throw (feet)
5 Degree T
15 Degree T
100 - 75 - 50
100 - 75 - 50
1
2
3
1
2
3
2
4
6
2
4
6
4
5
7
3
5
7
4
5
6
6
7
9
5
6
7
7
8
10
6
7
8
8
9
11
3
4
6
4
6
8
5
6
7
6
7
8
5
6
8
7
8
10
4
5
6
6
6
7
5
6
7
7
8
10
5
6
7
8
9
11

100, 75 OR
50FPM ISOVEL

HORIZONTAL
SPREAD (FT)

Critical Environment Diffusers

SUGGESTED SPECIFICATIONS
Air diffusers marked _______ shall be Titus model
number RadiaTec-AL. Diffusers shall be constructed using
a maximum 4 inches tall back pan (standard models) or
6-inch back pan (HEPA filter models) designed for optimum
performance of the diffuser. The back pan shall be divided
into two chambers connected via a baffle aperture designed
to evenly distribute air across the diffusers perforated face.
The back pan shall have integral hanger tabs for securing
the unit to the overhead structure. The baffles forming the
aperture will be located within the lower air chamber. The
face of the diffuser shall be constructed of 13 percent free
area perforated aluminum or -inch staggard centers.

PERFORMANCE

NC values shall be published. Throw for terminal velocities


of 100, 75 and 50 fpm shall be published along with
corresponding pressure drop. See the section, Engineering
Guidelines and the topic Procedure to Obtain Catalog Throw
Data for additional throw information. Performance tests
shall have been conducted in ASHRAE Standard 70-2006
and ASHRAE Standard 113-2009.

RADIATEC-SS

Use RadiaTec specification and make the following changes:


Change the model number to RadiaTec-SS.
Change all reference of aluminum to 304 Stainless Steel.

The interior of the diffuser shall be accessible for sanitization


and filter replacement from below (room-side) by loosening
the quarter-turn fasteners to allow the face to swing open,
and can be disengaged by releasing the retainer cables
attaching the face to the diffuser frame. The diffuser must
by available for full radial air diffusion (two-way) or onehalf radial air diffusion (one-way). The face and back pan
will be constructed of aluminum, but will be modular to
allow the face or back pan to be constructed of stainless
steel, if required. Options include HEPA filter rack and foam
gasketing.

www.titus-hvac.com | www.titus-energysolutions.com

RADIATEC

MODEL NUMBER SPECIFICATION

Model
RadiaTec-AL
RadiaTec-SS

Module Size (Note1)


24 x 24
48 x 24

XXXXXXXX-XX

XX

10
12

1-Way
2-Way

1
2
X

XX

XX

Finish

Inlet Size
8

XX x XX

Accessories
(Note 2)
HEPA Filter Rack
H
Foam Gasketing FG

Discharge
Pattern

8
10
12

White (std. for


RadiaTec-AL)

26

Mill (std. for


RadiaTec-SS

04

Note 1: 8 and 10-inch inlets available with 24 x 24 module; 10 and 12-inch inlets available with 48 x 24 module.
Note 2: Foam Gasketing is standard with HEPA Filter Rack option. Filter by Titus or others.

SPECIFICATIONS
R21

VERTICAL LAMINAR FLOW TECHNOLOGY



Available Models:

TLF

TLF-AA

TLF-SS

Steel
Aluminum
304 Stainless Steel

TLF

www.titus-hvac.com | www.titus-energysolutions.com

Critical Environment Diffusers

Laminar Pattern
TLF

Finish
Standard Finish - #26 White
Optional Finish - #04 Mill
Ideal for installation in hospital operating rooms.

Perforated face with 3/32-inch diameter holes on


-inch centers in a 60 staggered pattern.

Center plug removes from face for access to


screwdriver slot for damper adjustment.

Compatible with 1-inch or 1-inch T-bar ceiling grids.


Optional TRM mounting frame
available for surface mounting.

Perforated face quickly removes by loosening


quarter-turn fasteners.

Optional HEPA filter rack on TLF-AA and


TLF-SS. (Filter by Titus or others)

Retainer cables prevent the perforated face from falling


after removal.

Available in steel, aluminum or 304 stainless steel.

Internal baffles to distribute air


evenly over perforated face.

Neck
Size D
5, 6, 7, 8

Inlet
Height
B
2

10, 12

Ceiling Module Size C (Lay-In Applications)


Ceiling Opening = Module Size minus 1" (Surface Mount Applications)
C minus 3"
D
D
minus "

Retainer Cable

B
Deflector Ring
1"

Screwdriver Slot
C minus 1"

5"

"
-Turn

Fastener

Ceiling Opening
= Module Size C
minus 1" (Surface
Mount Applications)

C minus 1"

TLF

C minus "

C minus "

R22

* Without HEPA Filter. See page R23 for


depth with HEPA Filter.

Removable Center Plug


For Screwdriver Access

Critical Environment Diffusers

DIMENSIONS

TLF diffusers can be used to create clean zones by


positioning the diffuser directly over the area to be washed
with clean air. Clean zones are typically used as process
areas within a clean room.
TLF diffusers are also used in most operating rooms as
the center diffuser and many times these diffusers are
surrounded by a linear air curtain. The vertical piston of air
created by the TLF is used to discharge clean air over the
patient during operations.
Laminar flow minimizes air induction, reducing the
opportunity for contaminated air to be re-entrained and
pollute a clean airstream.

HEPA FILTER OPTION

The TLF Series of laminar flow diffusers generates a low


velocity, evenly distributed, downward moving piston of
conditioned air.
Installed over the operating table in a hospital operating
room, TLF diffusers help protect the patient from
contaminated room secondary air. The only appreciable
amount of room air entrainment occurs at the boundaries of
the moving air mass, outside the confines of the operating
table. As a result, the patient is effectively isolated from
residual room air.
TLF is especially effective in cooling areas with heavy,
localized, internal loads, as in computer rooms. The column
of air delivered by the TLF cools the load source directly
without generating high velocities in the occupied space.

TLF-AA/TLF-SS HEPA Filter Dimensions and Mounting Details

The Air Diffusers marked _______


shall be Titus Model (TLF-SS) (TLFAA) HEPA. The diffusers shall be
constructed using a 9 inch tall back
pan HEPA filter mounting rock and
knife edge. The filter, by Titus or
others, shall have a Gel Seal that the
knife edge fits into. The filter shall be
held in place using four #10-24 wing
nuts.

Inlet Ring
HEPA Filter
Gel Seal
(by others)

HEPA Filter to be furnished


and installed by others

www.titus-hvac.com | www.titus-energysolutions.com

OVERVIEW
TLF laminar flow diffusers are the industry standard for
unidirectional flow. When unidirectional flow is desired,
typically in areas classified as 1 to 1000, TLF is the choice.

HEPA Rack

9"

3"

HEPA
Filter

Knife Edge Dimension


of HEPA Rack
Length x Width

213/16"

Wing Nut

Module Size
(inches)

Knife Edge Dimensions


of HEPA Rack (inches)
Length
17

36 x 12

29

48 x 12

41

60 x 12

53

72 x 12

65

24 x 24

17

36 x 24

29

48 x 24

41

60 x 24

53

72 x 24

65

48 x 36

41

60 x 36

53

72 x 36

65

SECTIONAL VIEW

Width
HEPA Filter Rack
5

HEPA Filter Gel Seal (by Others)


Interior Edge Sealed

DIMENSIONS

24 x 12

Filter
Holding
Clip

17
HEPA Filter
Knife Edge

29

Wing Nut
Filter Holding Clip

R23

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

TLF, TLF-AA AND TLF-SS


7 Round Inlet
48 x 12
Module
60 x 12
Module
72 x 12
Module
24 x 24
Module
36 x 24
Module
48 x 24
Module
8 Round Inlet
48 x 24
Module
60 x 24
Module
72 x 24
Module
10 Round Inlet
48 x 24
Module
60 x 24
Module
72 x 24
Module

PERFORMANCE DATA

12 Round Inlet

R24

48 x 24
Module
60 x 24
Module
72 x 24
Module

Airflow (CFM)
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection

100
0.035
11
1-2-3
0.035
11
1-2-3
0.035
11
1-2-3
0.035
11
1-2-3
0.035
11
1-2-3
0.035
11
1-2-3

120
0.050
16
1-3-4
0.050
16
1-3-4
0.050
16
1-3-4
0.050
16
1-3-4
0.050
16
1-3-4
0.050
16
1-2-4

140
0.068
20
1-4-5
0.068
20
1-4-5
0.068
20
1-4-5
0.068
20
1-4-5
0.068
20
1-4-5
0.068
20
1-3-5

160
0.090
24
2-4-5
0.090
24
2-4-5
0.090
24
2-4-5
0.090
24
2-4-5
0.090
24
2-4-5
0.090
24
1-4-5

180
0.114
28
2-5-6
0.114
28
2-5-6
0.114
28
2-5-6
0.114
28
2-5-6
0.114
28
2-4-5
0.114
28
2-4-5

220
0.170
34
4-6-7
0.170
34
3-6-7
0.170
34
3-6-7
0.170
34
3-6-7
0.170
34
3-5-6
0.170
33
3-5-6

240
0.200
37
4-7-8
0.200
37
4-6-8
0.200
36
4-6-8
0.200
37
4-7-8
0.200
37
3-6-7
0.200
36
3-6-7

260
0.235
40
5-8-9
0.235
40
4-7-8
0.235
39
4-7-8
0.235
40
5-7-8
0.235
40
4-7-8
0.235
39
4-7-8

300
0.313
44
6-9-10
0.313
44
6-8-9
0.313
43
5-8-9
0.313
44
6-8-9
0.313
44
5-8-9
0.313
43
5-7-9

Airflow (CFM)
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection

100
0.020
1-2-3
0.020
1-2-3
0.019
1-2-3

120
0.027
1-2-3
0.027
1-2-3
0.027
1-2-3

140
0.038
14
1-3-4
0.038
14
1-3-4
0.037
14
1-3-4

160
0.050
18
1-3-4
0.049
18
1-3-4
0.048
18
1-3-4

180
0.062
22
1-4-5
0.061
22
1-4-5
0.060
22
1-4-5

220
0.090
28
2-5-6
0.089
28
2-5-6
0.088
28
2-5-6

240
0.113
31
2-5-6
0.109
31
2-5-6
0.105
31
2-5-6

260
0.130
33
3-6-7
0.126
33
3-6-7
0.124
33
3-5-7

300
0.175
37
4-7-8
0.168
37
3-7-8
0.162
37
3-6-8

Airflow (CFM)
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection

215
0.043
19
1-4-5
0.043
19
1-4-5
0.042
19
1-4-5

240
0.053
22
1-4-5
0.053
22
1-4-5
0.052
22
1-4-5

265
0.065
25
2-5-6
0.065
25
2-5-6
0.063
25
2-5-6

295
0.080
28
2-5-6
0.079
28
2-5-6
0.079
28
2-5-6

320
0.094
31
2-6-7
0.094
31
2-6-7
0.092
31
2-6-7

345
0.110
33
3-6-7
0.110
33
3-6-7
0.107
33
3-6-7

400
0.147
38
4-8-9
0.147
38
3-7-8
0.145
38
3-7-8

425
0.166
40
4-8-9
0.166
40
4-8-9
0.163
40
4-8-9

515
0.244
45
6-10-11
0.244
45
6-10-11
0.240
45
6-9-11

Airflow (CFM)
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection
Total Pressure
NC (noise Criteria)
Vertical Projection

215
0.023
11
1-4-4
0.023
11
1-4-4
0.023
11
1-4-4

240
0.029
15
1-4-5
0.029
15
1-4-5
0.028
15
1-4-5

265
0.035
18
1-4-5
0.035
18
1-4-5
0.034
18
1-4-5

295
0.043
22
1-5-6
0.043
22
1-5-6
0.042
22
1-5-6

320
0.051
24
2-6-6
0.051
24
2-6-6
0.050
24
2-5-6

345
0.059
27
2-7-7
0.059
27
2-6-7
0.058
27
2-6-7

400
0.080
32
2-7-8
0.080
32
2-7-8
0.078
32
2-7-7

425
0.090
34
3-7-8
0.090
34
3-7-8
0.088
34
2-7-8

515
0.132
40
4-9-10
0.132
40
4-8-10
0.129
40
3-8-10

All data based on full open damper position.


NC values are based on a room absorption of 10 dB.
Data obtained in accordance with ASHRAE Standard
70-2006 and ASHRAE Standard 113-2009.
Throw is based on 0-5B cooling with terminal
velocities of 75, 50 and 30 fpm.

Performance data does not include


pressure loss of optional HEPA filter.
See the section, Engineering Guidelines and
the topic Procedure to Obtain Catalog Throw
Data in this catalog for throw information.
Performance data for additional sizes not shown can
be obtained by using the Titus TEAMS program.

Critical Environment Diffusers

SUGGESTED SPECIFICATIONS
NC values shall be published. Throw for terminal velocities
of 75, 50 and 30 fpm shall be published along with
corresponding pressure drop.See the section, Engineering
Guidelines and the topic Procedure to Obtain Catalog
Throw Data in this catalog for catalog throw information.
Performance tests shall have been conducted in ASHRAE
Standard 70-2006 and ASHRAE Standard 113-2009.

TLF

Air diffusers marked _______ shall be Titus model number


TLF. Diffusers shall be constructed using a maximum 6
inches tall backpan designed for optimum performance with
the diffuser without HEPA filters. The backpan shall have
integral hanger tabs for securing the unit to the overhead
structure. Each unit shall have an integral internal baffle for
evenly distributing air over the entire face of the diffuser.
Each unit shall have an integral volume damper accessible
through the face of the diffuser. The face of the diffuser
shall be constructed of 22-gauge steel perforated with
3
/32-inch diagmeter holes on -inch centers. The free area
of the face shall be no greater than 13 percent. The face
shall be secured in place by quarter-turn fasteners for quick
removal and sanitizing. Each unit must have a removable
center plug for adjusting the damper.

TLF-AA

Air diffusers marked _______ shall be Titus model number


TLF-AA. Diffusers shall be constructed using a maximum 6
inches tall backpan designed for optimum performance with
the diffuser when unit is supplied without a HEPA filter. The

backpan shall have integral hanger tabs for securing the


unit to the overhead structure to prevent falling in case of
earthquakes or other ceiling damage. Each unit shall have
an integral internal baffle for evenly distributing air over the
entire face of the diffuser. Each unit shall have an integral
volume damper accessible through the face of the diffuser.
The face of the diffuser shall be constructed of 0.040inch thick aluminum and shall be perforated with 3/32-inch
diameter holes on -inch centers. The free area of the
face shall be no greater than 13 percent. The face shall be
secured in place by quarter-turn fasteners for quick removal
and sanitizing. Each unit must have a removable center plug
for adjusting the damper.

TLF-SS

Air diffusers marked _______ shall be Titus model number


TLF-SS. Diffusers shall be constructed using a maximum 6
inches tall backpan designed for optimum performance with
the diffuser. The backpan shall have integral hanger tabs for
securing the unit to the overhead structure to prevent falling
in case of earthquakes or other ceiling damage. Each unit
shall have an integral internal baffle for evenly distributing
air over the entire face of the diffuser. Each unit shall have
an integral volume damper accessible through the face of
the diffuser. The face of the diffuser shall be constructed
of 22-gauge 304 stainless steel perforated with 3/32-inch
diameter holes on -inch centers. The free area of the
face shall be no greater than 13 percent. The face shall be
secured in place by quarter-turn fasteners for quick removal
and sanitizing. Each unit must have a removable center plug
for adjusting the damper.

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE

MODEL NUMBER SPECIFICATION


Model
TLF
TLF-AA
TLF-SS
XXX-XX

Module Size
C x C
See table
below.

XX x XX

6
7
8
9
10
12

Earthquake Tabs

Note: For
availability
of inlet size
by module
size, see table
below.

XXX

Accessories
HEPA Filter Rack

XX

XX

Finish
EQT
H

White (std.)
Mill

26
04

(TLF-AA & TLF-SS only)

Available Nominal Ceiling Module Sizes C x C and Nominal Round Duct Sizes D

SPECIFICATIONS

XX

Inlet Size
(Round)

Material
ST
304 Stainless Steel
SS
Aluminum AA
Steel

C x C 24 x 12 24 x 24 36 x 12 36 x 24 48 x 12 48 x 24 48 x 36 60 x 12 60 x 24 60 x 36 72 x 12 72 x 24 72 x 36
D

5, 6, 7,
5, 6, 7,
5, 6, 7, 5, 6, 7,
5, 6, 7, 5, 6, 7,
5, 6, 7, 5, 6, 7,
5, 6, 7 8, 9, 10, 5, 6, 7 8, 9, 10, 5, 6, 7 8, 9, 10, 8, 9, 10, 5, 6, 7 8, 9, 10, 8, 9, 10, 5, 6, 7 8, 9, 10, 8, 9, 10,
12
12
12
12
12
12
12
12

R25


Available Models:

LineaTec-AL Aluminum

LineaTec-SS 304 Stainless Steel
Finish
Standard Finish - #26 White
Face (aluminum models).
Optional Finish - #04 Mill Finish
(304 stainless steel models
and plenums).

LINEATEC
R26

OVERVIEW
LineaTec is a linear air curtain
diffuser used to create an air
curtain barrier between a clean
zone and the balance of the room.
The air curtain typically discharges
25 to 50 cfm per linear foot of
slot. Flow rates of up to 100 cfm
per linear foot of diffuser can be
obtained with a two-slot LineaTec.
LineaTec diffusers are typically
used to surround TLF diffusers in
operating rooms to reduce internal
contaminants in the sterile zone of
the operating theatre. With limited
adjustable slots, the air curtain
can be directed at a slight angle to
facilitate balancing airflow in the
entire operating theatre through
directional control.
To meet sanitizing requirements,
LineaTec diffusers are available
with plenums that have optional
corners radiused to -inch. This
allows easy manual cleaning of the
inside of the plenum when the face
is removed and reduces crevices
where bacteria and other organisms
can grow. Select LineaTec diffusers
based on 50 fpm terminal velocity
at knee height to 24 inches above
floor - for most operating room
applications.

Utilizes a free area slot with an


adjustable deflector for maximum
efficiency and versatility.
LineaTec

www.titus-hvac.com | www.titus-energysolutions.com

LINEAR AIR CURTAIN TECHNOLOGY


VERTICAL AIR CURTAIN 2-SLOT
DIFFUSER FOR PERIMETER CONTROL OF
POLLUTANTS

LineaTec provides a curtain of


supply air.

Critical Environment Diffusers

Linear Air Curtain


LineaTec

Face available in 304 Stainless


Steel or aluminum.
Available in single sections up to 6
inches long or multiple sections for
continuous runs.
Available with optional
304 Stainless Steel or
aluminum plenums.

Plenums available with square


or round corners, quarter-turn
fasteners for easy face removal
and sanitizing.
Excellent for use as a perimeter air
curtain in clean air environments
such as operating rooms.

Blank-off sections can be provided


to blank-off a single slot.

May be used in surface mount


or lay-in applications.

LineaTec Diffuser Mounting Diagram


T-Bar Lay-In

Surface Mounted
Hanger Wire

Ceiling
Tile

Hanger Wire

T-Bar
(15/16" wide
Tee)

Hanger Bracket

Hanger Bracket

Ceiling
Tile

Module Length
Note: Module Width for Lineatec - AL is 15 7/16," Liineatec - SS is 15"

Available Single Section Lengths


Length
Mounting
2
Surface(1)
3
Surface(1)
36
Surface(1)
4
Surface(1)
46
Surface(1)
5
Surface(1)
56
Surface(1)
6
Surface(1)
2
T-bar Lay-In(2)
3
T-bar Lay-In(2)
4
T-bar Lay-In(2)

Note 1: May be used as T-bar lay-in by


making the T-bar grid nominal unit
LineaTec-SS: Length + 31/4 inches long by
151/4 inches wide. LineaTec-AL: Length +
31/16 inches long by 151/16 inches wide.
Note 2: Length fits in standard 2-, 3-, or
4-foot T-bar grid. Grid width must be 151/4
inches (151/16 inches for LineaTec-AL).

LineaTec-AL - Single Unit Construction Face View

LineaTec-SS - Single Unit Construction Face View

Critical Environment Diffusers

DIMENSIONS

LineaTec-AL - Continuous Unit Construction


Overall Nominal Length plus 33/16"
Overall Nominal Length

Connected with
aluminum joiner strips
Available Single
Section Lengths
(ft.)
Length
2
3
36
4
46
5
56
6

Overall Nominal Length minus 6"

153/16"

12"

Aluminum
Joiner Mullion
Nominal Length plus
119/32"
(Left section)

Nominal Length
(Intermediate section)

Nominal Length plus


119/32"
(Right section)

LineaTec-SS - Continuous Unit Construction


Overall Nominal Length plus 3"
Overall Nominal Length
Overall Nominal Length minus 6"

15"

OPTIONAL PLENUM
CONSTRUCTION
Available with corners
rounded (-inch radius)
or with square corners.
Bolted together in
the field.
Hanger brackets
included.
Square or rectangular
inlets available in
5-, 6- or 8-inch heights.
For flange details see
page R26.

www.titus-hvac.com | www.titus-energysolutions.com

CONTINUOUS UNIT
CONSTRUCTION

Aluminum
Joiner Mullion
Nominal Length plus
1"
(Left section)

Optional
Plenum
Nominal Length
(Intermediate section)

Nominal Length plus


1"
(Right section)

Plenum Construction - Single Unit Construction


No

12"

12"

No

mi

1"

mi

na

lL

12"

en

gth

" Dia.
2"

1"
12"

na

lL

en

2"

" Dia.
1"

1"

Rounded Corners

gth

Square Corners

Support Wires
(by others)
Hanger Brackets

Bolt Flanges
Optional
Optional
Together
Rounded Corner
Squared Corner
Plenum Detail
Plenum Detail
Ceiling Opening = Overall Nominal Length plus "

DIMENSIONS

Plenum Construction - Continuous Unit Construction

R27

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS

OPTIONAL PLENUM INLET


Inlets centered horizontally.
5-, 6- or 8-inch tall inlets available.
Section
Length

Maximum Inlet Length

24
36
42
48
54
60
66
72

12
24
30
36
42
48
54
60

Left Plenum Section


Inlet Length

Inlet
Height

6"

Center Plenum Section


Flange

Flange
Inlet Length

Note: Maximum inlet velocity is 1,000


fpm, 500 fpm is preferred. Operating
range of 1-slot unit is 10 cfm/ft to 90
cfm/ft. Operating range of 2-slot unit is
20 cfm/ft to 180 cfm/ft in typical rooms.
With higher ceilings, the performance
table may be extended to cfms greater
than those shown.

Inlet
Height

6"

Note: Inlet heights available are 5, 6 or


8 inches.
Note: Each linear diffuser should have a
supply duct connection.

Flange

Right Plenum Section


Flange
Inlet Length

Inlet
Height

DIMENSIONS

6"

R28

Critical Environment Diffusers

PERFORMANCE DATA

1-Slot

2-Slot

Airflow, cfm/Ft.
Static Pressure
NC (Noise Criteria)
Throw
Airflow, cfm/Ft.
Static Pressure
NC (Noise Criteria)
Throw

10
0.004
<10
0-1-3
20
0.004
<10
0-1-4

20
0.015
<10
1-3-6
40
0.015
<10
2-4-8

30
40
50
60
70
0.034 0.061
0.095
0.136
0.186
<10
<10
13
16
19
3-4-7
4-6-8
5-6-9
6-7-10
6-7-11
60
80
100
120
140
0.034 0.061
0.095
0.136
0.186
<10
19
26
31
37
4-6-10 6-8-11 7-9-(13) 8-10-(14) 9-11-(15)

NC is based on a 6-foot unit.


Throw is based on isothermal air, vertical, in a
room between 0 and 11 feet high, for 150, 100
and 50 fpm terminal velocities, for a 6-foot unit.
For cold air, throw will increase, heated air will not
project as far as shown; See the section, Engineering
Guidelines and the topic, Estimating Downward Vertical
Projection in this catalog for additional information.

Throw data included in () parenthesis is


calculated to exceed floor to ceiling distance
for the terminal velocities shown.
Static pressure shown assumes Titus
recommended plenum.
Data is based on a factory provided plenum with
-inch radiused corner and an 18 x 6-inch inlet.

www.titus-hvac.com | www.titus-energysolutions.com

LINEATEC-AL AND LINEATEC-SS

PERFORMANCE DATA
R29

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

PERFORMANCE

NC values representing the noise criteria curve shall be


published. Throw values for terminal velocities of 150, 100,
and 50 fpm shall be published along with corresponding
pressure drop. Performance shall be based on a factory
manufactured plenum. Performance tests shall have been
conducted in accordance with ASHRAE Standards 70-2006
and ASHRAE Standard 113-90.

LINEATEC-AL

Linear air diffusers marked _______ shall be Titus model


number LineaTec-AL. Diffusers shall be constructed for
a 12-inch wide plenum. The diffuser shall be a two-slot
design with provision for disabling one slot. Diffuser shall
be available in one piece construction up to 6 feet long or
multiple piece construction for longer lengths. Multisection
diffusers shall include joiner mullions. Slots shall include
adjustable blades with a minimum adjustment range of
5 to 15. Diffuser shall be constructed of heavy gauge
extruded aluminum. An outer extruded frame and factory
manufactured aluminum plenum shall be installed on the
diffuser.
The diffuser must have quarter-turn fasteners for quick and
easy removal from the plenum. The plenum shall have all
outer corners radiused with a -inch, minimum, radius.

(Option-the plenum shall have square corners.) The plenum


inlet shall be 5, 6 or 8 inches high and of sufficient length to
reduce the velocity of incoming air to 1,000 fpm or less.

LINEATEC-SS

Linear air diffusers marked _______ shall be Titus model


number LineaTec-SS. Diffusers shall be constructed for
a 12-inch wide plenum. The diffuser shall be a two-slot
design with provision for disabling one slot. Diffuser shall
be available in one piece construction up to 6 feet long or
multiple piece construction for longer lengths.
Multisection diffusers shall include joiner mullions. Slots
shall include adjustable blades with a minimum adjustment
range of 5B to 15. Diffuser shall be constructed of minimum
22-gauge 304 stainless steel with a #04 brushed finish. An
outer frame and factory manufactured 304 stainless steel
plenum shall be installed on the diffuser and shall have a
mill finish. The diffuser must have quarter-turn fasteners
for quick and easy removal from the plenum. The plenum
shall have all outer corners radiused with a minimum -inch
radius. (Option-the plenum shall have square corners.) The
plenum inlet shall be 5, 6 or 8 inches high and of sufficient
length to reduce the velocity of incoming air to 1,000 fpm or
less.

MODEL NUMBER SPECIFICATION


Inlet Width
Model
LineaTec-AL
LineaTec-SS
XXXXXXXX-XX

SPECIFICATIONS

Nominal Length
Specify

R30

Number of Inlets
Specify

X
Inlet Height
5
6
8

(Specify to the
nearest 1 increment.
Maximum length is
section size minus
12). Note: Inlet is
actual size.

One-Slot
Blank-Off
Plate

5
6
8

Construction

Corner
Square Corners
radius vertical and
horizontal corners
(does not apply to
inlet)

S
R

Accessories
R
X

XX

Finish (Note)
White (std.)
Mill

26
04

Note: Finish applies to face only. Plenum is mill finish. Standard finish: Aluminum - White; Stainless Steel - Mill
Mill finish only available on stainless Steel models.

Critical Environment Diffusers

Linear Air Curtain (continued)

STERILE ENVIRONMENT SYSTEM TECHNOLOGY


Aluminum
304 Stainless Steel

SteriTec


Available Models:

SteriTec-AL

SteriTec-SS

Perforated pressure induction plate facilitates balancing.


Blades have minimum adjustability to allow precise
control of the air curtain angle.
Optional blank-off plate is available for closing off one
slot.
May be mounted as surface mount or T-bar lay-in with
support.

Available with optional 304 stainless steel or


aluminum plenums.

Available in square sizes from 8 x 8 feet through 20


x 20 feet as listed below. Rectangular sizes are also
available.

Corner transitions are full plenum size creating no


airflow restriction.

Other custom sizes are available.

Available with round corners on plenums (-inch


radius) or square corners on plenums

Two-slot perimeter air curtain for creating an air wall


between clean zones and adjacent area.
Unique corner transition allows the entire plenum
system to be visible for cleaning by hand.

www.titus-hvac.com | www.titus-energysolutions.com

SteriTec

Continuous plenums minimize duct runs and facilitates


self balancing.
Typical linear selection for 50 fpm terminal velocity 2
feet above floor.

Face quickly removes for easy plenum access.


Unique corner covers provide neat appearance.
Total
Linear Diffuser
Nominal
Laminar Flow
No. of Sections
LineaTec
Sizes ft. No. of Units & Sizes
Laminar
A x B Units @ 30cfm/ft2 Side A Side B Flow cfm @ 40 cfm/
ft cfm
8
10
12
14

x
x
x
x

8
10
12
14

16 x 16

1296
1920
1920
3120

2
2
2
2

2
2
2
2

1296
1,920
1,920
3,120

1200
1,600
1,920
2,240

2575
3,520
3,840
5,360

3120

3,120

2,560

5,680

4320
7680

3
4

3
4

4,320
7,600

2,380
3,200

7,200
10,800

Note: Please check with your Titus representative before specifying sizes other than
those listed above. See page R37. Rectangular sizes are available.

STERITEC

18 x 18
20 x 20

6-3x2
8-2x4
8-2x4
10-2x4
2-2x6
10-2x4
2-2x6
18-2x4
32-2x4

cfm

R31

www.titus-hvac.com | www.titus-energysolutions.com

OVERVIEW

STERITEC

R32

According to the new proposed


ASHRAE standard for critical hospital
operating rooms, the laminar flow
diffusers should be selected for an
average velocity not to exceed 35 fpm
at the operating table. This is about
equal to the normal plumage velocity
emitted from the human body. This
velocity can be calculated by taking
airflow from the laminar flow diffusers
and dividing this flow by the nominal
face area of the diffusers. The size of
the laminar flow field or many times
called the serial field, should be at
least the size of the operating table
plus an additional area of 12 inches
around the table. This is the absolute
minimum size. However, many times
additional equipment and tables are
required and also need to be included
in this sterile field. The sterile field
should protect the patient and provide
non-contaminated airflow protection
for the patient, all equipment and
personnel being used for the patient.
The terminal velocity of the laminar
flow on the patient should not be
greater than the plumage velocity
created by the normal human body
at rest. This limitation is meant to
stop the laminar flow from driving
contamination into open wounds
during surgery the plumage velocity is
approximately 25-35 fpm.
Ceiling area can be allowed in the
sterile field for lighting and related
services. Data has shown that if an
air wall or air curtain like the SteriTec
is used, room airflow entrainment is
drastically reduced into the laminar
flow sterile field with as much as 30%
of the sterile field used for related
services. Tests, conducted at the Titus
laboratory, have shown the importance
of this air wall or air curtain. If an
air curtain is not used as shown for
both a side view and a plan view
contamination can and will be induced
into the center of the sterile field. The
migration of contamination has also
been observed if the laminar diffusers
are continuous over the operating
room table and an air curtain has not
been used. As shown, the inside edge
of the SteriTec system air wall or air
curtain should be mounted 12 to 30
inches outside the TLF generated

Critical Environment Diffusers


nominal sterile field. The total airflow
requirement varies with the room size.
The recommended minimum airflow is
20 air changes per hour for class B and
C operating rooms.
The side view of the SteriTec air
curtain shows how this system stops
room airflow induction into the laminar
flow field at two very important
locations. The first location is next to
the ceiling. If the laminar flow is not
continuous, and many times this is
not the case due to lighting and gas
columns etc., the air wall stops the
induction along the ceiling line from
being drawn into the laminar flow. The
openings in the field can and does
provide a material pathway for airflow
to flow into the openings between
the laminar flow diffusers. This then
can allow secondary room airflow to
flow into these areas which may be
contaminated. The second area of
protection is seen further down in the
room. The SteriTec air curtain provides
an invisible barrier or wall to reduce
room air from being mixed with the
pure filtered clean laminar flow from
the TLF diffusers.
Contaminated air outside the air
curtain is prevented from entraining
or being mixed with the clean zone
created and inside the LineaTec
diffusers zone. In most applications
the LineaTec diffusers of the SteriTec
system are selected for a terminal
velocity of 50 fpm about 2 Feet above
the floor. This allows the flow to travel
down to and along the floor to the
external low sidewall exhaust return
grilles.
The SteriTec system combines the
features of the TLF and the LineaTec
to form a clean zone within a clean
room. A typical SteriTec system for an
operating room of class B or C includes
a LineaTec perimeter air curtain and
with TLF laminar flow TLF diffusers as
the central supply air outlets. Return
grilles are located at the low level
sidewall as exhaust outlets on at least
two of the rooms walls. These are
typically mounted so the lower portion
of the grille frame is about 8 inches
above the floor to allow cleaning of the
rooms floor.

No Air Curtain - Contamination - Not


Blocked At Ceiling
Plan View
Diffusers

OR Table

20'
Contaminates
s

Blanked Off Area

20'

Laminar Flow With No Air Curtain


Diffuser
Contaminates

Contaminates

12"

OR Table

Side View

Laminar Flow With Air Curtain


12 - 30"

12 - 30"

Diffuser

Contaminates

Contaminates

OR Table

Side View

Air Curtain With Non-continuous Laminar


Flow - Contamination Blocked
Plan View

12 - 30"

20'
Contaminates

Air Curtain
20'

Critical Environment Diffusers

DIMENSIONS

Standard Plenum Finish



Optional Finish - #04 Mill

NOMINAL SYSTEM LENGTH 'B'


PLUS 1 3 4"

Finish
Standard Face Finish

SteriTec-AL - #26 White Face

SteriTec-SS - #04 Mill

16 23 32 "

NOMINAL SYSTEM LENGTH 'B'


PLUS 35 3 16 "

SteriTec-SS
20-gauge 304 stainless steel
face and plenums.

SteriTec-AL - Face View


NOMINAL SYSTEM LENGTH 'A'
PLUS 35 3 16"
NOMINAL SYSTEM LENGTH 'A'
PLUS 1 3 4"

JOINER MULLION USED


BETWEEN SECTIONS - MULTIPLE
SECTIONS USED ON LARGE
SYSTEMS ACCORDING TO SYSTEM
SIZE

SLOT
DIFFUSER

1/4 TURN
FASTENERS

CORNER
PANEL

OPERATING
TABLE

THE TLF DIFFUSER WITH


OR WITHOUT INTEGRAL
HEPA FILTERS, ARE PLACED
IN THE CENTER OF THE
STERITEC LINEAR DIFFUSER
ASSEMBLY. THE TLF LAMINAR
FLOW DIFFUSERS ARE TO BE
LOCATED OVER THE ENTIRE
WORK AREAS ABOVE AND
AROUND THE OPERATING
ROOM TABLE.

Note: Outside ceiling opening for surface mounting is nominal system length +
34 inches. Outside T-bar grid dimensions for T-bar lay-in mounting are nominal
system length + 357/16-inch.

www.titus-hvac.com | www.titus-energysolutions.com

Material:
SteriTec-AL
Extruded aluminum face with
20-gauge aluminum plenum.

SteriTec-SS - Face View


Corner
Panel

Nominal System Length "A" plus 35"


Nominal System Length "A"
plus 1"
16"
Slot
Diffuser

Nominal
System
Length "B"
plus 1"
Nominal
System
Length "B"
plus 35"

Joiner mullion
used between
sections, multiple
sections used on
large system
according to
system size

TLF Laminar
Diffusers

Note: Outside ceiling opening for surface mounting is nominal system length
+ 34 inches. Outside T-bar grid dimensions for T-bar lay-in mounting are nominal
system length +351/4-inch.

DIMENSIONS

Operating Table

R33

Critical Environment Diffusers

Optional -inch radius on


horizontal and vertical plenum
corners (inlet does not
have radius).

Top View - 8 x 8 feet, 10 x 10 feet, 12 x 12 feet Systems


16 "
16 "

Continuously welded seams


ground smooth to make hand
cleaning easy.
Corners have no crevices
on radiused plenums to trap
contaminants or mold.
12-inch width to facilitate cleaning.
Optional square cornered plenums
with tightly fitted end caps spotwelded in place.

NOMINAL SYSTEM LENGTH 'A'


PLUS 32"
NOMINAL SYSTEM LENGTH 'A'

SUPPLY
INLET

NOMINAL SYSTEM LENGTH 'B'

PLENUMS INCLUDE:

NOMINAL SYSTEM LENGTH 'B'


PLUS 32"

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS

SUPPLY
INLET

Plenums have heavy duty hanger


brackets for suspending the entire
system from the structure.

Multi-section plenums bolt


together using heavy duty flanges.

System Nominal Size Nominal


(ft)
C
8x8
4
10 x 10
5
12 x 12
6
14 x 14
4
16 x 16
5
18 x 18
6

NOMINAL PLENUM LENGTHS


Note: Use the chart shown at right for
identifying nominal plenum section
lengths by system size.

Plenum Length
D
E
4

5
4
5
5
6
6

(ft)
F

5
5
6

Rectangular sizes are available.


Top View - 14 x 14 feet, 16 x 16 feet, 18 x 18 feet Systems
NOMINAL SYSTEM LENGTH 'A'
PLUS 32"
NOMINAL SYSTEM LENGTH A'

16 "
16 "

NOMINAL SYSTEM LENGTH 'B'

NOMINAL SYSTEM LENGTH 'B'


PLUS 32"

DIMENSIONS

SUPPLY
INLET

SUPPLY
INLET

SUPPLY
INLET

C
SUPPLY
INLET

R34

Critical Environment Diffusers

DIMENSIONS

Top View - 20 x 20, 22 x 22, 24 x 24 Systems


NOMINAL SYSTEM LENGTH 'A'
PLUS 32"

Note: Use the chart shown at right for


identifying nominal plenum section
lengths by system size.

NOMINAL SYSTEM LENGTH 'A'

NOMINAL SYSTEM LENGTH 'B'


PLUS 32"

FLANGE AND HANGER


BRACKET DETAILS
Note: All systems must be suspended by
wire whether surface mount or lay-in.

NOMINAL SYSTEM LENGTH 'B'

SUPPLY
INLET

D
SUPPLY
INLET

SUPPLY
INLET

SUPPLY
INLET

System Nominal Size Nominal Plenum Length (ft)


(ft)
C
D
E
F
20 x 20
5
5
5
5

Connecting Flange Details


1"
(Typ.)

www.titus-hvac.com | www.titus-energysolutions.com

NOMINAL PLENUM LENGTHS

Hanger Bracket Details

14"
3"

2"
"

1"

"

" Dia. hole


"

2"
13"

3"

7/16"

Dia. hole
(13 holes)

Plenum

15"
Dim A = 15 3/16" Steritec - AL or 15" Steritec - SS

Weld
Side View

End View

DIMENSIONS
R35

www.titus-hvac.com | www.titus-energysolutions.com

PLENUM INLET LOCATIONS


Note: Inlets should be of equal size.
Maximum inlet size is 8 inches tall by
the section length minus 12 inches. Inlet
velocity should be kept to less than 800
fpm, preferably less than 500 fpm.

Critical Environment Diffusers


System Layout A - Top View
2

Plenum Segment
(Typ.)
3

8' x 8' and 12' x 12'


Systems

7
Typical
Inlet
5

System Layout B - Top View

12

11

14' x 14', 16' x 16'


and 18' x 18' Systems

10

Typical
Inlet

PLENUM SLOT LOCATIONS

System Layout C - Top View


1

16

15
20' x 20'
Systems

14

Typical
Inlet

13

R36

12

11

10

Critical Environment Diffusers

SUGGESTED SPECIFICATIONS
Linear air curtain system marked _______ shall be Titus
SteriTec system. Linear diffusers shall be constructed for a
12-inch wide plenum. The diffuser shall be a two-slot design
with provision for blanking off one-slot. Linear diffusers shall
include pressure induction plates for automatic balancing of
airflow. Slots shall include adjustable blades with a minimum
adjustment range of 5 to 15. Diffuser shall be constructed
of heavy extruded aluminum (or 20-gauge 304 stainless
steel for SteriTec-SS).
An outer frame and factory manufactured plenum shall be
installed on the diffuser. The diffuser must have quarter-turn
fasteners for quick and easy removal from the plenum. The
plenum shall have all outer corners radiused with a -inch,
minimum, radius.
All welded joints shall be ground smooth. (Option-plenums
shall have square corners.) Plenums must be connected
at all joints using bolt together flanges. The system shall
have ____ inlets which shall be 5, 6 or 8 inches high and
be of sufficient length to reduce the velocity of incoming
air to ____ fpm or less. The corners of the system shall
be interconnected using transition elbows with removable
face covers. Corner transitions shall not reduce the cross

sectional area of the plenum. Removable face covers shall


expose the entire corner section of the plenum for cleaning
and visual inspection.
Center diffusers shall be Titus model number ________ (see
model specification).
System parameters shall be as follows:
Room Volume _____ft.3
Air Changes Per Hour ______
Nominal System Size
______ x ______
Total System cfm ______
Perimeter Air Curtain cfm ______
Number of TLF Diffusers ______
cfm/TLF Diffuser _______

cfm/Linear ft. of Slot Diffuser ______

MODEL NUMBER SPECIFICATION


Inlet Width
Model
SteriTec-AL
SteriTec-SS
XXXXXXXX-XX

Number of Inlets
(Use inlet
Specify
location chart
to determine
correct
number)

Nominal Length A*
Specify

X
Inlet Height
5
6
8

See Plenum Inlet


Locations for
maximum inlet
size
available

X
5
6
8

www.titus-hvac.com | www.titus-energysolutions.com

STERITEC

X
Total
System
cfm
Specify

Perimeter cfm
Specify

XX

XX

Number of
Interior Diffusers
Specify

Interior Diffuser
Specification
(Add the
appropriate diffuser
model number
specifications to
the end of this
specification.)

* For standard system sizes, see page R31.

SPECIFICATIONS
R37

Available Models:

FFD

FFDE

FFDR

FFDER

PSC motor / HEPA Filter


ECM motor / HEPA Filter
PSC motor / Room side replaceable HEPA Filter
ECM motor / Room side replaceable HEPA Filter

INTRODUCTION
Fan filter diffusers provide a unique solution in clean room
applications. In situations where the use of conventional
ducted modules is impractical or the air supply has
insufficient static pressure to move the air through a HEPA
filter, fan filter diffusers provide an excellent alternative.
In cleanroom design, the primary factor is contaminant
removal and the cleanliness level, so moving the air is a
major challenge. The volume of recirculated HEPA filtered
air, including conditioned air to handle high cooling loads
that are typical of many cleanrooms, can range from less
than twenty to more than five hundred air changes per hour.
Fan filter diffusers provide a constant flow of clean air into
the space which prevents the infiltration of contaminants
and provides for the removal of particles generated by
people and equipment in the work space.

TITUS FAN FILTER DIFFUSERSLOW


ENERGY, LOW SOUND AND LOW
PROFILE

FAN FILTER DIFFUSERS

Titus offers a complete line of fan filter diffusers that can be


used for new design or retrofitting cleanroom environments.
Each Titus FFD (fan filter diffuser) is a self-contained fan
filter module that includes HEPA filter, pre-filter, fan speed
control and low profile design. Air circulation is maintained
by using a lightweight, forward curved fan powered by a
120V or 277V, 60Hz motor. Motor speed is adjusted by the
solid-state speed control mounted on top of the housing.
Patented baffling technology ensures uniform airflow
across the filter face and attenuates sound for one of the

R38

Critical Environment Diffusers


Fan Filter Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

Fan Filter Diffusers

quietest fan filter diffusers in the industry. The room


side replaceable option (R) provides quick and efficient
replacement of the HEPA or ULPA filter from room side while
the diffuser remains in place.
Titus fan filter diffusers are also available with an ECM
brushless DC motor. These units dynamically adjust
themselves to maintain the set airflow, compensating for
changes in static pressure, filter loading or other local
conditions. Titus fan filter diffusers with ECM can easily
maintain cleanroom air levels exceeding IEST recommended
practices. Airflow is maintained so constantly and
consistently that the need for future balancing is greatly
reduced. The ECM option, along with the patented baffling
system and forward curve fan, makes Titus fan filter
diffusers intelligent, energy efficient and ultra quiet.







Low profile design.


PSC or ECM motor.
Solid state, visual, or infrared speed control.
Walkable plenum (excluding prefilter).
UL listed (120V, 277V).
Standard sizes: 24 x 24 and 48 x 24.
Aluminum construction (stainless steel optional).
Options: Duct collar, challenge port,
ULPA filter, power cord.

Critical Environment Diffusers

DIMENSIONS

www.titus-hvac.com | www.titus-energysolutions.com

24X24 FFD
D

In (mm) In (mm) In (mm) In (mm)

23 5/8

23 5/8

23 11/32

23 11/32

(600)

(600)

(606)

(606)

SPEED CONTROL

SNAP-IN
PREFILTER

7/8 KNOCKOUT FOR


INCOMING POWER
ON/OFF SWITCH

318
12 1/2"

241
9 1/2"

48X24 FFD
A

C
E

In (mm) In (mm) In (mm) In (mm)


47 5/8

23 5/8

47 11/32

23 11/32

(1210)

(600)

(1215)

(606)

3SPEED
SPEED CONTROL
SWITCH OR
SPEED CONTROL
7/8 KNOCKOUT FOR
INCOMING POWER
ON/OFF SWITCH

318
12 1/2"

240
9 7/16"

DIMENSIONS

SNAP-IN
PREFILTER

R39

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS
24X24 FFDE
C

Unit
Weight

In (mm) In (mm) In (mm) In (mm) In (mm) In (mm)

23 5/8

23 5/8

23 11/32

23 11/32

21 3/8

21 3/8

(600)

(600)

(606)

(606)

(543)

(543)

41 lbs.

Note: The maximum inlet static pressure is 0.3 inches of


water gauge. Operating above the maximum may adversely
affect the performance of the unit and is not recommended.
SNAP-IN
PREFILTER
1/4-20 UNC THREADED INSERT
PULL-OUT RATING: 1180 LBS
4 PLCS

VISUAL SPEED CONTROL


7/8 KNOCKOUT FOR
INCOMING POWER
ON/OFF SWITCH

364
14 3/8"

241
9 1/2"

48X24 FFDE
A

C
E

DIMENSIONS

47 5/8

23 5/8

47 11/32

23 11/32

45 3/8

21 3/8

(1210)

(600)

(1215)

(606)

(1152)

(543)

VISUAL SPEED CONTROL

1/4-20 UNC THREADED INSERT


PULL-OUT RATING: 1180 LBS
4 PLCS

7/8 KNOCKOUT FOR


INCOMING POWER
ON/OFF SWITCH

364
14 5/16"

240
9 7/16"

Unit
Weight

In (mm) In (mm) In (mm) In (mm) In (mm) In (mm)

SNAP-IN
PREFILTER

R40

62 lbs.

Critical Environment Diffusers

DIMENSIONS

Unit
Weight

In (mm) In (mm) In (mm) In (mm) In (mm) In (mm)

23 5/8

23 5/8

23 11/32

23 11/32

21 3/8

21 3/8

(600)

(600)

(606)

(606)

(543)

(543)

44 lbs.

SNAP-IN
PREFILTER

SPEED CONTROL

1/4-20 UNC THREADED INSERT


PULL-OUT RATING: 1180 LBS
4 PLCS

7/8 KNOCKOUT FOR


INCOMING POWER

www.titus-hvac.com | www.titus-energysolutions.com

24X24 FFDR

ON/OFF SWITCH

373
14 11/16"

296
11 5/8"

48X24 FFDR
A

C
E

In (mm) In (mm) In (mm) In (mm) In (mm) In (mm)

47 5/8

23 5/8

47 11/32

23 11/32

45 3/8

21 3/8

(1210)

(600)

(1215)

(606)

(1152)

(543)

71 lbs.

3 SPEED SWITCH OR
SPEED CONTROL

SNAP-IN
PREFILTER

7/8 KNOCKOUT FOR


INCOMING POWER
ON/OFF SWITCH

370
14 9/16"

293
11 1/2"

DIMENSIONS

1/4-20 UNC THREADED INSERT


PULL-OUT RATING: 1180 LBS
4 PLCS

Unit
Weight

R41

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS
24X24 FFDER

C
E

Unit
Weight

In (mm) In (mm) In (mm) In (mm) In (mm) In (mm)

23 5/8

23 5/8

23 11/32

23 11/32

21 3/8

21 3/8

(600)

(600)

(606)

(606)

(543)

(543)

44 lbs.

Note: The maximum inlet static pressure is 0.3 inches of


water gauge. Operating above the maximum may adversely
affect the performance of the unit and is not recommended.
SNAP-IN
PREFILTER
1/4-20 UNC THREADED INSERT
PULL-OUT RATING: 1180 LBS
4 PLCS

VISUAL SPEED CONTROL


7/8 KNOCKOUT FOR
INCOMING POWER
ON/OFF SWITCH

419
16 1/2"

296
11 5/8"

48X24 FFDER
A

C
E

DIMENSIONS

47 5/8

23 5/8

47 11/32

23 11/32

45 3/8

21 3/8

(1210)

(600)

(1215)

(606)

(1152)

(543)

VISUAL SPEED CONTROL

1/4-20 UNC THREADED INSERT


PULL-OUT RATING: 1180 LBS
4 PLCS

7/8 KNOCKOUT FOR


INCOMING POWER
ON/OFF SWITCH

417
16 7/16"

294
11 9/16"
A

Unit
Weight

In (mm) In (mm) In (mm) In (mm) In (mm) In (mm)

SNAP-IN
PREFILTER

R42

68 lbs

OPTIONS & ACCESSORIES

Critical Environment Diffusers


www.titus-hvac.com | www.titus-energysolutions.com

FFD & FFDE

FFDR & FFDER

R
FILTER & GEL SEAL DETAIL: FFDR, FFDER
Lower housing is welded with full penetration welds
providing a leak free mate to the gel seal filter. No caulk
is required.

Diffuser screen is interference fit with housing,


no hardware required.

CHALLENGE & COLLABORATION PORT DETAIL

OPTIONS & ACCESSORIES


* Challenge and calibration ports are
standard on FFDR & FFDER models.
They are are available as options on FFD
and FFDE models.

R43

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

Model: FFD
Airflow/Power Consumption
Nominal
Size

Motor
Hp

Voltage @ Maximum airflow


CFM

Watts

@ 90 FPM
CFM

Max
Amps

Watts

Heat Gain Sound


(BTU/Hr) Level
@ 90 FPM dBA

Active Filter
Face Area
(sq ft)

Unit
Weight
(lbs)

24 x 24

1/5

120V

410

200

315

165

3.0

563

48.0

3.5

41

24 x 24

1/5

277V

410

200

315

165

1.2

563

48.0

3.5

41

48 x 24

1/5

120V

660

315

650

310

3.0

1058

51.0

7.2

66

48 x 24

1/5

277V

660

315

650

310

1.2

1058

51.0

7.2

66

Active Filter
Face Area
(sq ft)

Unit
Weight
(lbs)

Model: FFDR
Airflow/Power Consumption
Motor
Hp

CFM

Watts

CFM

Watts

24 x 24

1/5

120V

350

170

210

140

3.0

478

48.0

2.3

44

24 x 24

1/5

277V

350

170

210

140

1.2

478

48.0

2.3

44

48 x 24

1/5

120V

610

300

470

245

3.0

836

51.0

5.3

71

48 x 24

1/5

277V

610

300

470

245

1.2

836

51.0

5.3

71

Active Filter
Face Area
(sq ft)

Unit
Weight
(lbs)

Voltage @ Maximum airflow

@ 90 FPM

Max
Amps

Heat Gain Sound


(BTU/Hr) Level
@ 90 FPM dBA

Nominal
Size

Model: FFDE
Airflow/Power Consumption
Nominal
Size

Motor
Hp

Voltage @ Maximum airflow


CFM

Watts

@ 90 FPM
CFM

Max
Amps

Watts

Heat Gain Sound


(BTU/Hr) Level
@ 90 FPM dBA

24 x 24

1/3

120V

410

145

315

80

3.4

273

47.0

3.5

41

24 x 24

1/3

277V

410

145

315

80

1.7

273

47.0

3.5

41

48 x 24

1/3

120V

660

260

650

235

3.4

802

48.0

7.2

66

48 x 24

1/3

277V

660

260

650

235

1.7

802

48.0

7.2

66

Active Filter
Face Area
(sq ft)

Unit
Weight
(lbs)

47.0

2.3

44

Model: FFDER

PERFORMANCE DATA

Airflow/Power Consumption

R44

Nominal
Size

Motor
Hp

Voltage @ Maximum airflow

@ 90 FPM

CFM

Watts

CFM

Watts
50

24 x 24

1/3

120V

350

130

210

24 x 24

1/3

277V

350

130

210

48 x 24

1/3

120V

610

225

470

48 x 24

1/3

277V

610

225

470

110

Max
Amps

Heat Gain Sound


(BTU/Hr) Level
@ 90 FPM dBA

3.4

171

50

1.7

171

47.0

2.3

44

110

3.4

375

48.0

5.3

71

1.7

375

48.0

5.3

71

Notes:
Airflow is tested in accordance with (ANSI/AMCA 210-07), (ANSI/ASHRAE 51-07)
test standards for Certified Aerodynamic Performance Rating
Max CFM rating based on free air volumes at high speed motor setting
90 fpm values based on active face area
Heat gain: BTU = watts x 3.413
Max amps calculated using nominal power factor of 0.70

Critical Environment Diffusers

SUGGESTED SPECIFICATIONS
Fan Filter Diffusers shall be Titus models: FFD, FFDE, FFDR,
FFDER for the sizes and mounting type as shown on the
plans and outlet schedule. The diffuser shall be configured
to deliver a filtered laminar airflow over the diffuser face.
Standard construction shall include a patented baffle system
as part of the fan plenum housing. Diffuser shall be UL507
listed with a UL Class 2 filter. Diffuser shall be furnished
with a 30% (20PPI) polyurethane foam, washable prefilter
(to be removed with round inlet option). Diffuser shall
contain a HEPA filter that is factory tested and rated at
99.99% efficiency in removal of particles 0.3 microns and
larger, and leak free in accordance with the latest I.E.S.T.
recommended practices. Filter shall be auto scanned for
efficiency and leakage prior to final assembly of the fan filter
diffuser. Filter media shall be microglass fiber with hot melt
separators, sealed to the aluminum housing. Diffuser shall
contain a fan/motor assembly that is a direct drive, forward
curve centrifugal type with permanently lubricated steel ball
bearings. Bearings are rated for L-10 life of 80,000 hours.
Fan Filter Diffuser models: FFD, FFDR, shall have a
permanent split capacitor type motor rated for continuous
duty and furnished with thermal overload protection and
Solid State Speed Control (SSSC). Diffuser models: FFDE,
FFDER, shall have an electrically commutated motor (ECM)

and digital visual speed control (VSD). Diffuser models:


FFDR, FFDER shall have a removable face and room side
access to integral HEPA filter.
Optional ULPA filters (rated at 99.9995% at 0.12 microns),
and PTFE (Boron free) filters are available.
The plenum and filter housing shall have a #04 Mill finish.
Optional powder coat paint or stainless steel exterior is
available. Diffuser models: FFD, FFDE shall be constructed
with an epoxy powder coated steel face.
Fan Filter Diffusers shall meet or exceed the requirements of
the following industry standards: ISO Class 5(Class 100 (M
3.5)) air per the latest I.E.S.T. 14644-1 (Airborne Particulate
Cleanliness Classes). I.E.S.T Recommended Practices
(Laminar Flow Clean Air Devices). Averaged measured air
velocity will be 90 ft/min (10 ft/min), when measured
using a Velgrid (eight readings) at 6 below diffuser face.
All measured values shall fall within 20% of the measured
average. The sound level shall be approximately 51 dBA
(below NC 45) measured at 30 from diffuser face with an
average airflow velocity of 90 ft/min. Noise measurements
are taken with a clean filter and no external static pressure.
Vibration level will not exceed .09 MILS RMS at 90 ft/min.

MODEL NUMBER SPECIFICATION

Model
FFD
FFDE
FFDR
FFDER
XXXXX

Module
Size

Duct Collar

24 x 24
48 x 24

XX

Finish
01
04
26
XX

Material
Aluminum

Filter

0 (none)
10
12
XXXXX

www.titus-hvac.com | www.titus-energysolutions.com

FAN FILTER DIFFUSERS

Aluminum
Mill
White

XX

HEPA
ULPA
PTFE
XXX

120V
240V
277V

XXX
Accessories

Voltage
AL

XXXX

120
240
277

Airflow Indicator Port


Challenge Port
Infared Speed Control

AIL
CHP
ISC

* Challenge and calibration ports are


standard on FFDR & FFDER models.

SPECIFICATIONS
R45

HEPA FILTER LED LIGHT KIT



Available Model:
HEPALERT

HEPALERT, HEPA Filter LED Light Kit for TLF


and RadiaTec diffusers with HEPA filter
The HEPALERT LED light kit automatically
monitors filter loading using differential
pressure sensors and LED status lights.
LED lights illuminate from green
to red when the pressure set
point for filter replacement has
been reached (A green light
indicates the filter continues to
clean, while a red light indicates
the filter needs to be replaced).

HEPALERT is designed for Titus


TLF and RadiaTec diffusers with
HEPA filters.
LED kit eliminates need to
remove diffuser face to visually
check filter cleanliness.
LEDs are visible from occupied
area.
HEPALERT switch (field calibrated)
activates LED when filter-free
area becomes fifty percent
restricted. Instructions are
included for field calibration.
Kit is shipped loose and requires
field installation.

Diffuser
Backpan

Left End
(Short Side)

HEPALERT

5"

R46

5"

6"

HEPALERT

www.titus-hvac.com | www.titus-energysolutions.com

Critical Environment Diffusers

Accessories
HEPALERT

24 VAC transformer required


(supplied by others).
Filter operation is unaffected by
room pressure changes.

Critical Environment Diffusers

Accessories (continued)

www.titus-hvac.com | www.titus-energysolutions.com

HEPA FILTER

R
Filter Part
Number

Nominal
Size

Effective Face
Area (Sq ft)

HF2412T

24 X 12

16-3/4

6-1/8

HF3612T

36 X 12

28-3/4

6-1/8

3-1/16

9-1/16

18-1/8

4-3/4

0.37

3-1/16

15-1/16

30-1/8

4-3/4

HF4812T

48 x 12

40-3/4

0.66

6-1/8

3-1/16

21-1/16

42-1/8

4-3/4

HF6012T

60 x 12

0.94

52-3/4

6-1/8

3-1/16

27-1/16

54-1/8

4-3/4

HF7212T

1.23

72 x 12

64-3/4

6-1/8

3-1/16

33-1/16

66-1/8

4-3/4

1.52

HF2424T

24 x 24

16-3/4

18-1/8

9-1/16

9-1/16

18-1/8

16-3/4

1.66

HF3624T

36 x 24

28-3/4

18-1/8

9-1/16

15-1/16

30-1/8

16-3/4

2.94

HF4824T

48 x 24

40-3/4

18-1/8

9-1/16

21-1/16

42-1/8

16-3/4

4.23

HF6024T

60 x 24

52-3/4

18-1/8

9-1/16

27-1/16

54-1/8

16-3/4

5.52

HF7224T

72 x 24

64-3/4

18-1/8

9-1/16

33-1/16

66-1/8

16-3/4

6.81

HF4836T

48 x 36

40-3/4

30-1/8

15-1/16

21-1/16

42-1/8

28-3/4

7.52

HF6036T

60 x 36

52-3/4

30-1/8

15-1/16

27-1/16

54-1/8

28-3/4

9.81

HF7236T

72 x 36

64-3/4

30-1/8

15-1/16

33-1/16

66-1/8

28-3/4

12.09

FILTER SPECIFICATIONS

Filter has a downstream gel seal to mate with diffuser


HEPA knife edge. Gel seal material is Blu-Jel.

Filter efficiency is 99.99% with 0.3 micron


particles per standard: IES-RP-CC-001.3 (Institute
of Environmental Science & Technology).

Filter media is 007 Dimple-pleat (ME-D0700).


Pack style is 2 dimple pleat.

Filter is constructed of fire-rated materials


per standard: UL-900 class 1.

The filter resistance to airflow will be a maximum


of 0.52 water gauge at 100 fpm. Refer to chart on
page R48 for additional pressure drop values.

Filter has a centerboard with (1) port for damper


operation. Cadmium plated screw (included with filter)
must be inserted into port while filter is in use.

Filter is scan tested for leaks at an air flow of 100 fpm.

Frame material is extruded anodized aluminum.

The filter maximum operating temperature is 250 F,


and the maximum relative humidity (R.H.) is 100%.

Filters are non-hygroscopic.

HEPA FILTER

Titus HEPA filters are designed specifically


to fit the Titus TLF and RadiaTec diffusers
manufactured after 6/10/07. These filters will not
fit diffusers manufactured before that date.

R47

Critical Environment Diffusers

www.titus-hvac.com | www.titus-energysolutions.com

Accessories (continued)
Nominal
Filter Size
24 x 12
36 x 12
48 x 12
60 x 12
72 x 12
24 x 24
36 x 24

48 x 24
60 x 24
72 x 24
48 x 36
60 x 36

HEPA FILTER

72 x 36

R48

CFM

11

15

19

22

30

37

44

Pressure

0.080

0.11

0.15

0.21

0.26

0.32

0.42

0.53

0.68

CFM

10

13

20

26

33

40

53

66

79

Pressure

0.08

0.11

0.15

0.21

0.26

0.33

0.43

0.54

0.69

CFM

14

19

28

38

47

56

75

94

113

Pressure

0.07

0.09

0.14

0.19

0.29

0.36

0.42

0.60

0.68

CFM

18

25

37

49

62

74

98

123

148

Pressure

0.08

0.11

0.15

0.21

0.27

0.33

0.44

0.54

0.70

CFM

23

30

46

61

76

91

122

152

182

Pressure

0.07

0.09

0.14

0.19

0.25

0.30

0.42

0.52

0.66

CFM

25

33

50

66

83

100

133

166

200

Pressure

0.07

0.09

0.14

0.19

0.25

0.30

0.42

0.52

0.66

CFM

44

59

88

118

147

176

235

295

353

Pressure

0.07

0.09

0.14

0.19

0.25

0.30

0.42

0.52

0.66

CFM

63

85

127

170

212

254

338

423

508

Pressure

0.07

0.10

0.14

0.20

0.25

0.30

0.42

0.52

0.66

CFM

83

110

166

221

276

331

442

552

663

Pressure

0.07

0.10

0.14

0.20

0.25

0.31

0.42

0.52

0.66

CFM

102

136

204

272

340

409

545

681

817

Pressure

0.08

0.10

0.14

0.20

0.25

0.31

0.42

0.52

0.66

CFM

113

150

226

301

376

451

601

752

902

Pressure

0.08

0.10

0.15

0.21

0.26

0.31

0.42

0.52

0.66

CFM

147

196

294

392

490

589

785

981

1177

Pressure

0.08

0.11

0.15

0.21

0.26

0.31

0.42

0.53

0.67

CFM

181

242

363

484

605

725

967

1210

1450

Pressure

0.08

0.11

0.15

0.21

0.26

0.31

0.42

0.53

0.67

Pressure loss values listed above are measured


in inches of water gauge (w.g.)

Pressure loss value is for an unused filter


only. This value must be added to the diffuser
pressure drop to determine total pressure.

Critical Environment Diffusers

Application Notes

primary supply diffuser array area may be allocated for nondiffuser use such as lights, gas columns, etc. but caution is
advised. The air curtain, or air wall, is recommended around
the sterile field to stop contamination from entrainment
along the ceiling line and along the outer perimeter of
the airflow coming down form the TLF supply diffusers.
(See page R31 for more details.) Most operating rooms
are now recommended to be designed at a minimum 20
air changes per hour (ACPH). The new guidelines do not
state a minimum. The airflow should be HEPA filtered and
the operating room is normally at a positively pressure.
Most codes call for the return grilles to be located at the
external lower wall areas above the floor level in the corners
of the room. For critical operating rooms a LineaTec air
curtain should be added. The air curtain provides an air wall
outside the laminar airflow zone to decrease entrainment
or induction into the laminar airflow perimeter. The air
curtain is normally selected for a terminal velocity of 50 fpm
at 2 feet. above the floor The Titus LineaTec diffuser has
a deflector that can be adjusted to deflect the air stream
inward or slightly outward.

SYSTEM SIZING AND LAYOUT


SYSTEM CALCULATIONS STEPS
1. Determine room size.
2. Determine desired number of air changes with a
mimimum of 4 outdoor air changes per hour for the
SteriTec perimeter air curtain and the TLF internal
diffusers.
3. Determine SteriTec nominal system size.
4. Determine desired total
system cfm.
5. Determine perimeter air
curtain cfm.
6. Determine internal diffuser cfm (usually 50 to 75 percent
of the total cfm).
7. Select number of inlets and the location from the chart
shown.
8. Determine number TLF units and
System Layout
inlet size for each unit.

Nominal System Length "A" plus 353/16"

Corner
Panel

New ASHRAE guidelines point to


providing continuous pillar of laminar
airflow air distribution over the
operating table and personnel as well
the surgical instrument table. These
guidelines indicate the laminar airflow
velocity should not exceed 25-35
fpm at the patient. The reason is the
laminar flow should not overcome the
natural plumage of airflow from the
body and allow the laminar flow to
drive contaminants in a wound. New
data has now been shown that space
inside the sterile field can be used
for lighting, gas connections, etc. This
data shows that up to 30% of the

www.titus-hvac.com | www.titus-energysolutions.com

TITUS OPERATING ROOM AIR


DISTRIBUTION SYSTEM

Nominal System Length "A"


plus 1"

1623/32"
Joiner mullion
used between
sections - multiple
sections used on
large system
according to
system size

Slot
Diffuser

Nominal
System
Length "B"
plus 1"
Nominal
System
Length "B"
plus 353/16"

The TLF diffuser, with


or without integral
HEPA filters, are
placed in the center
of the SteriTec linear
diffuser assembly.
The TLF laminar flow
diffusers are to be
located over the entire
work ares above
and around the operating
room table.

Operating Table

Turn Fasteners

The operating room system specifications table provides SteriTec and TLF specifications based on different combinations of
ACPH and room dimensions. Rectangular sizes can also be used.
Ceiling

Changes Height
Per Hour

(ft.)

20
25
30
35
20
25
30
35

10
10
10
10
10
10
10
10

SteriTec Specifications
Room
Dim. (ft.)
30 x 38
30 x 31
28 x 27.5
27 x 26
44 x 45
39 x 40
36 x 37
33 x 34

Dim. (ft.)

Active

System Max Inlet

A+B

Slots

Layout* Size (in.) Required

12
12
12
12
14
14
14
14

x
x
x
x
x
x
x
x

12
12
12
12
14
14
14
14

2
2
2
2
2
2
2
2

*Refer to page R36 for Plenum Inlet Location diagrams.


**cfm for 30 fpm see R29
A.F. = Above Floor

A
A
A
A
B
B
B
B

60
60
60
60
42
42
42
42

x
x
x
x
x
x
x
x

8
8
8
8
8
8
8
8

Inlets

4
4
4
4
8
8
8
8

1,
1,
1,
1,

3,
3,
3,
3,

TLF Specifications

Plenum Inlet

Total

Locations*

cfm

2, 4, 6, 8
2, 4, 6, 8
2, 4, 6, 8
2, 4, 6, 8
4, 6, 7, 9, 10,
4, 6, 7, 9, 10,
4, 6, 7, 9, 10,
4, 6, 7, 9, 10,

12
12
12
12

1,920
1,920
1,920
1,920
2,240
2,240
2,240
2,240

Required System Information


Room Volume _____ft3.
Air Change per Hour _____.
SteriTec Dimensions _____ x _____.

Throw (ft.) No.


@ 50 fpm

of

@ 2 A.F.

units

8
8
8
8
8
8
8
8

8
8
8
8
18
18
18
18

Inlet
Dim. (in.) Size
(in.)
24
24
24
24
24
24
24
24

x
x
x
x
x
x
x
x

48
48
48
48
48
48
48
48

12
12
12
12
10
10
10
10

Total
cfm
1,920
1,920
1,920
1,920
4,320
4,320
4,320
4,320

Throw
to 30
fpm
7
7
7
7
7
7
7
7

System Total cfm _____.


SteriTec Total cfm _____.
Number of TLF diffusers _____.
cfm per TLF diffuser _____.

System
Total
cfm
3,840
3,840
3,840
3,840
6,560
6,560
6,560
6,560

APPLICATION NOTES

Air

R49

www.titus-hvac.com | www.titus-energysolutions.com

Application Notes (continued)

OPERATING ROOM AIR DISTRIBUTION SYSTEM


The discussion presented in the application notes are
intended as aids to heating and air conditioning engineers
and designers with skill and knowledge about clean room
design. Titus has no control over the system design and
application of these critical environment products, a function
that rightfully belongs to the designer.
Contaminated air outside the air curtain is prevented from
entering the clean zone by the air curtain. Contaminated
air in the clean zone is pushed down and outward by the
laminar flow on the interior of the clean zone.
The interior of the system should have the highest room
pressure due to velocities and air volume from the air
diffusers.
Velocities should be kept to a maximum of 35 fpm at
operating table height so the natural plumage velocity
of the patient is not over powered and helps to prevent
contaminants from getting into open wounds during surgery.
The laminar flow diffuser should have quarter-turn fasteners
and all internal parts shall be removable for cleaning and
sterilization.
The entire operating room is usually under positive pressure
created by dampering exhaust air and by providing
extra makeup air. This helps to prevent an ingress of
contaminated particles from outside the clean room. As
doors or dividers are opened or parted, the positive internal
pressure causes air to flow toward the lower external
pressure outside the clean environment. The outward
airflow forces particles away from the interior zone. Some
hospital rooms are designed for negative pressure to keep
contaminants from contaminating other hospital areas and
endangering other people.

APPLICATION NOTES

Plenums for LineaTec diffusers used in operating rooms


usually have radiused corners. Corners are radiused with a
-inch radius to facilitate cleaning and to avoid areas where
microorganisms can grow, later contaminating incoming
clean air. The face of the LineaTec can be removed by
rotating quarter-turn fasteners.

R50

Critical Environment Diffusers


The entire plenum is then exposed to the maintenance
worker. The plenum system is usually interconnected so a
minimum number of inlets can be utilized for incoming air
from the air handler.
Corner transitions are utilized so the plenum can be
continuous, even at the corners. Corner transitions found
on Titus plenum systems are covered on the operating
room side by a cover plate. When the plate is removed,
the entire plenum corner is exposed for easy cleaning. The
cover plate itself can be put in an autoclave for sterilization.
Some competitive models utilize an elbow behind the ceiling
as corner transitions. To clean the corner transitions, the
maintenance worker must reach around the corner in areas
that are hidden from sight; this is not recommended.
The operating room design engineer determines the number
of ACPH based on the cleanliness level desired and current
industry standards. Plenum inlets are sized so the maximum
inlet velocity is in the 500 fpm range. Inlets can be
lengthened and made longer to reduce entrance velocities
or multiple inlets can be used. Plenum velocities should be
kept as low as possible to facilitate automatic balancing of
the air curtain. The 800 fpm range is considered top end,
400 to 500 fpm is desirable.
Total room airflow should be divided between the perimeter
air curtain and the center diffusers. The perimeter air
curtain should be supplying air between 25 to 50 cfm per
foot. HEPA filters should be located remotely.
The standard material of construction is 304 stainless steel.
The 304 stainless steel offers durability and an attractive
appearance; plus it can withstand manual sterilization using
harsh chemicals normally encountered for this purpose. The
standard finish is #04 mill finish.
Manual balancing dampers should be sufficient to allow
balancing of individual duct branches. Design flow rates to
the interior clean zone should be established through normal
balancing procedure by a certified air balancing professional.
The perimeter zone should be adjusted to obtain the
required cfm per foot as designed.

Critical Environment Diffusers

Basic Cleanroom Terminology

LAMINAR FLOW CLEANROOM

A clean room with airflow in nominally one direction


(ASHRAE 1999 Applications Handbook).

MAKEUP AIR

CLEANLINESS CLASSIFICATION (CLASS)

Number of particles per cubic foot based on the


requirements outlined in Federal Standard 209. See the
following graph. For example, the ASHRAE 1999 Applications
Handbook defines a Class 10,000 clean room as a clean
room where the particle count does not exceed 10,000
particles per cubic foot of a size 0.5 micrometers and larger,
or 65 particles per cubic foot of a size 5.0 micrometers
and larger.

CLEANROOM

An enclosed area especially constructed for environmentally


controlling airborne particulates, temperature, humidity, air
pressure, airflow patterns, air motion, vibration, noise, viable
organisms, and lighting.

Air introduced to the secondary (recirculated) air system for


ventilation, pressurization and replacement of exhaust air.

PARTICLE CONCENTRATION

The number of individual particles per unit volume of air


(ASHRAE 1999 Applications Handbook).

PARTICLE SIZE

The maximum linear dimension of a particle expressed in


micrometers (10-6 meters).

SECONDARY AIR

Air that recirculates through the workspace (ASHRAE 1999


Applications Handbook).

PRIMARY AIR

FIRST AIR

Portion of primary air circulated through the air conditioning


equipment.

HIGH-EFFICIENCY FILTER (HEPA)

A filter with a minimum efficiency of 99.999 percent of 0.12


micrometer particles, as determined by DOP test (ASHRAE
1999 Applications Handbook).

The air that issues directly from the HEPA filter before it
passes over any work location (ASHRAE 1991 Applications
Handbook).

ULTRA LOW PARTICULATE AIR FILTER (ULPA)

A filter with an efficiency in excess of 99.97% of 0.3


micrometer particles, as determined by DOP test (ASHRAE
1999 Applications Handbook).

www.titus-hvac.com | www.titus-energysolutions.com

CLEAN AREA

A defined area within a clean room designed for


environmentally controlling airborne particulates,
temperature, humidity, air pressure, airflow patterns, air
motion, vibration, noise, viable organisms, and lighting.

WORK AREA

A defined area environmentally controlled and designed for


specific tasks.

100,000

Class
100,000

10,000

Class
10,000

1,000

Class
1,000

CLEANROOM TERMINOLOGY

Particles per Cubic Foot

Air Cleanliness Class Limits U.S. Federal Standard 209

100
Class
100
10

Class
10

1
Class 1
0.1
0.01

0.02

0.05

0.1

0.2

0.5

10

Particle Size, um

R51

Notes

Critical Environment Diffusers

displacement ventilation

T
www.titus-hvac.com | www.titus-energysolutions.com

www.titus-hvac.com | www.titus-energysolutions.com

Table of Contents

Displacement Ventilation

displacement ventilation products


Displacement Ventilation Products................................................................................................................................................ T4

overview
Overview......................................................................................................................................................................................... T7
Application Guide........................................................................................................................................................................... T8
Introduction to Displacement Ventilation............................................................................................................................... T8
Air Change Effectiveness........................................................................................................................................................ T8
Typical Applications................................................................................................................................................................ T9
Contaminant Removal............................................................................................................................................................. T9
Benefits & Limitations............................................................................................................................................................ T9
Energy Considerations............................................................................................................................................................ T9
Outlet Characteristics........................................................................................................................................................... T10
The Adjacent Zone ............................................................................................................................................................... T10
Outlet Choices....................................................................................................................................................................... T10
Heat Sources & Convective Flows........................................................................................................................................ T11
Space Temperature Gradients & Airflow Rates..................................................................................................................... T11
Air Pattern Projection............................................................................................................................................................ T11
Methods of Evaluation.......................................................................................................................................................... T12
Supply Air Connections......................................................................................................................................................... T12
Acoustical Performance........................................................................................................................................................ T12
Displacement Ventilation Theory & Governing Equations.................................................................................................... T12
Design Procedure for Displacement Ventilation................................................................................................................... T14
Design Examples................................................................................................................................................................... T15
References............................................................................................................................................................................ T21

DISPLACEMENT VENTILATION

rectangular displacement

T2

DVBC............................................................................................................................................................................................. T22
Accessories........................................................................................................................................................................... T23
Performance Data................................................................................................................................................................. T24
Suggested Specifications...................................................................................................................................................... T25
Model Number Specifications.............................................................................................................................................. T25
DVIR.............................................................................................................................................................................................. T26
Accessories........................................................................................................................................................................... T28
Performance Data................................................................................................................................................................. T29
Suggested Specifications...................................................................................................................................................... T31
Model Number Specifications.............................................................................................................................................. T31
DVRI.............................................................................................................................................................................................. T32
Accessories........................................................................................................................................................................... T34
Performance Data................................................................................................................................................................. T35
Suggested Specifications...................................................................................................................................................... T37
Model Number Specifications.............................................................................................................................................. T37
DVR3............................................................................................................................................................................................. T38
Accessories........................................................................................................................................................................... T40
Performance Data................................................................................................................................................................. T41
Suggested Specifications...................................................................................................................................................... T43
Model Number Specifications.............................................................................................................................................. T43

semi-circular displacement
DV180........................................................................................................................................................................................... T44
Accessories........................................................................................................................................................................... T45
Performance Data................................................................................................................................................................. T46
Suggested Specifications...................................................................................................................................................... T48
Model Number Specifications.............................................................................................................................................. T48
DVHC............................................................................................................................................................................................ T49
Accessories........................................................................................................................................................................... T51
Performance Data................................................................................................................................................................. T52
Suggested Specifications...................................................................................................................................................... T54
Model Number Specifications.............................................................................................................................................. T54

Table of Contents (continued)

Displacement Ventilation

DVC1............................................................................................................................................................................................. T55
Accessories........................................................................................................................................................................... T57
Performance Data................................................................................................................................................................. T58
Suggested Specifications...................................................................................................................................................... T60
Model Number Specifications.............................................................................................................................................. T60
DVVC............................................................................................................................................................................................. T61
Accessories........................................................................................................................................................................... T63
Performance Data................................................................................................................................................................. T64
Suggested Specifications...................................................................................................................................................... T66
Model Number Specifications.............................................................................................................................................. T66

circular displacement
DVCP............................................................................................................................................................................................. T67
Accessories........................................................................................................................................................................... T68
Performance Data................................................................................................................................................................. T69
Suggested Specifications...................................................................................................................................................... T70
Model Number Specifications.............................................................................................................................................. T70

heating & cooling displacement options


DVRI-HC Plexicon......................................................................................................................................................................... T71
DVRI-HC 14 Accessories....................................................................................................................................................... T72
DVRI-HC 32 Accessories....................................................................................................................................................... T73
Performance Data - Cooling.................................................................................................................................................. T74
Performance Data - Heating................................................................................................................................................. T75
Suggested Specifications...................................................................................................................................................... T76
Model Number Specifications.............................................................................................................................................. T76

www.titus-hvac.com | www.titus-energysolutions.com

corner mount displacement

displacement ventilation adjustment


Diffuser Adjustment..................................................................................................................................................................... T77

DISPLACEMENT VENTILATION
T3

www.titus-hvac.com | www.titus-energysolutions.com

Displacement Ventilation Products

DISPLACEMENT VENTILATION

T4

Displacement Ventilation
RECTANGULAR DISPLACEMENT

pages: T8-T26

DVBC

DVIR

DVRI

DVR1

WALL MOUNT
APPLICATIONS

FLUSH MOUNT
APPLICATIONS

FLUSH OR SURFACE
MOUNT APPLICATIONS

STAIR RISER
APPLICATIONS

3-way air discharge pattern.


Supplies a large amount of air at low
velocity into the occupied zone.
Enhanced pattern controllers
for easy adjustment.
Standard finish is #26
white powdercoat.

1-way discharge air pattern.


Supplies small to medium
amounts of air at low velocity
into the occupied zone.
Enhanced pattern controllers
for easy adjustment.

1-way air discharge pattern.


Supplies a large amount of air at low
velocity into the occupied zone.
Enhanced pattern controllers
for easy adjustment.
Standard finish is #26
white powdercoat.

1-way air discharge pattern.


Supplies small to medium
amounts of air at low velocity
into the occupied zone.
Enhanced pattern controllers
for easy adjustment.
Standard finish is #26
white powdercoat.

DVR3
WALL MOUNT
APPLICATIONS
3-way air discharge pattern
Supplies a large amount of air at low
velocity into the occupied zone.
Enhanced pattern controllers
for easy adjustment.
Standard finish is #26
white powdercoat.

Displacement Ventilation

Displacement Ventilation products (continued)

DV180

DVHC

WALL OR SURFACE MOUNT APPLICATIONS

WALL OR SURFACE MOUNT APPLICATIONS

180B air discharge pattern.


Supplies a large amount of air at low velocity into the occupied zone.
Enhanced pattern controllers for easy adjustment.
Standard finish is #26 white powdercoat.

180B air discharge pattern.


Supplies a large amount of air at low velocity into the occupied zone.
Enhanced pattern controllers for easy adjustment.
Standard finish is #26 white powdercoat.

www.titus-hvac.com | www.titus-energysolutions.com

SEMI-CIRCULAR DISPLACEMENT

pages: T27-T34

CORNER MOUNT DISPLACEMENT

pages: T35-T42

DVVC

CORNER MOUNT APPLICATIONS

CORNER MOUNT APPLICATIONS

90B air discharge pattern.


Supplies a large amount of air at low velocity into the occupied zone.
Enhanced pattern controllers for easy adjustment.
Standard finish is #26 white powdercoat.

90B air discharge pattern.


Supplies a large amount of air at low velocity into the occupied zone.
Enhanced pattern controllers for easy adjustment.
Standard finish is #26 white powdercoat.

DISPLACEMENT VENTILATION

DVC1

T5

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

Displacement Ventilation products (continued)

CIRCULAR DISPLACEMENT

pages: T43-T46

DVCP
FLOOR APPLICATIONS



360B air discharge pattern.


Supplies a large amount of air at low velocity into the occupied zone.
Enhanced pattern controllers for easy adjustment.
Standard finish is #26 white powdercoat.

HEATING & COOLING OPTIONS

DISPLACEMENT VENTILATION

pages: T47-T52

T6

DVRI-HC 14

DVRI-HC 32

WALL OR SURFACE MOUNT APPLICATIONS

WALL OR SURFACE MOUNT APPLICATIONS

Dual function diffuser for cooling and heating.


Top section - Displacement cooling.
Bottom section - Heating
Standard finish is #26 white powdercoat.

Dual function diffuser for cooling and heating.


Top section - Displacement cooling.
Bottom section - Heating
Standard finish is #26 white powdercoat.

Overview

The Displacement Ventilation system is similar to an


UnderFloor Air Distribution (UFAD) system in that is uses
warmer supply air and lower pressures then a conventional
overhead system. As a result, displacement ventilation
systems have many of the same benefits of UFAD systems,
such as longer economizer periods, potential energy savings
from the warmer supply air and lower horsepower fans, and
quiet operation. Although many parts of North America need
to cool the supply air below 65BF for humidity reasons, all
areas should benefit from the increased economizer time.
An additional benefit to Displacement Ventilation systems is
that ASHRAE Standard 62.1-2007 Ventilation for Acceptable
Indoor Air Quality gives Displacement Ventilation systems
a Ventilation Effectiveness Factor of 1.2. Ventilation
Effectiveness is a measure of how effectively the zone air
distribution uses its supply air to maintain acceptable air
quality in the breathing zone. A Ventilation Effectiveness of
1.2 means that a lower volume of fresh air can be used to
meet ASHRAE 62.1 requirements. This makes displacement
ventilation systems an effective way to achieve the LEED
Increased Ventilation credit.

One of the challenges to displacement ventilation is that the


diffusers are placed in the occupied zone, typically along the
wall. Because displacement diffusers supply air directly into
the room, placement of occupants is critical to achieving a
comfortable space. The ASHRAE Guideline recommends that
the air velocity in the occupied space not exceed 50 fpm.
For a displacement diffuser, the zone where the velocity
exceeds 50 fpm is called the adjacent zone or near zone.
Occupants need to be placed outside of the adjacent zone
for comfort. A typical displacement diffuser can maintain
comfort in a space that is 5-6 times the length of the
adjacent zone.
Titus has a full line of displacement ventilation diffusers to
accommodate any application. One unique and specifiable
feature of Titus displacement diffusers is the variable air
pattern controllers located behind the perforated face.
The pattern controllers can be adjusted to change the
size and direction of the supply air isovel and adjacent
zone area. Engineers may not always know the final room
layout or furniture location during the design phase. Titus
displacement diffusers provide the perfect solution by
offering adjustability without the need to move or change
the location of the diffuser. This ability to shape and
customize the airflow pattern and adjacent zone to match
requirements in the occupied space ensures the highest
level of thermal comfort for building occupants.

www.titus-hvac.com | www.titus-energysolutions.com

Displacement Ventilation systems use low velocity cold air


to displace warm room air. They are defined by ASHRAE as
fully stratified systems. Supply air is introduced low in the
occupied space and travels along the floor until it reaches
a heat source, such as a person or computer. Natural
convection flows cause the supply air to rise around the
heat source.

Displacement Ventilation

DISPLACEMENT VENTILATION
T7

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE

Displacement Ventilation

Displacement Ventilation Design


& Application Guide
Buildings come in all shapes and sizes and are designed
for any number of purposes. In order to create healthy and
productive environments, air distribution systems must be
selected that best meet the goals of designers. There are a
wide range of choices available, but often one system can
be identified as the best solution in terms of cost, comfort
and energy. The purpose of this guide is to explain how
displacement ventilation works, describe recommended
applications and provide engineering guidance to the system
designer.

INTRODUCTION TO DISPLACEMENT VENTILATION

In order to understand the advantages and limitations of


displacement ventilation, its important to understand the
differences between conventional mixed air distribution and
fully-stratified air distribution.
In mixed air distribution, hot or cold supply air is delivered
at relatively high velocity from ceiling-mounted diffusers.
When ceiling diffusers are properly selected and positioned,
this high velocity air doesnt result in occupant discomfort
because it is delivered outside the occupied zone. The
purpose of the high velocity supply is to create low velocity
room air motion through entrainment. Ideally, this air
motion will thoroughly mix the supply air with the room air
resulting in uniform temperature and contaminant levels
throughout the occupied zone. Internal heat loads and
contaminants are eventually picked up and carried away by
the return air.

Figure 2. Fully-Stratified System


The main differences between these systems are:
Mixed air distribution
Suitable for both heating and cooling with a
supply temperature range of 38 to 90F.
Air is supplied to the unoccupied zone
at relatively high velocity.
Minimizes temperature variations throughout the space.
Creates uniform contaminant concentration
throughout the zone.
Fully-stratified air distribution
Suitable for cooling only with a supply
temperature range of 62 to 70F.
Air is supplied directly to the occupied
zone at low velocity.
Takes advantage of natural air buoyancy
to divide the zone into two regions.
Heat and pollutants rise into the upper unoccupied zone.
Contaminant concentration is greatly
reduced in the lower occupied zone.

APPLICATION GUIDE

AIR CHANGE EFFECTIVENESS

T8

ASHRAE Standard 62.1-2010 Ventilation for Acceptable


Indoor Air Quality assigns a zone air distribution
effectiveness value (Ez ) of 1.0 for conventional mixed air
systems and 1.2 for fully-stratified systems (Table 6-2). This
means that fully-stratified systems are 20% more effective
than the best mixed air systems and can provide the same
level of ventilation with a 16.7% reduction in air volume.
This reduces the amount of outdoor air necessary to meet
ventilation requirements.
Figure 1. Mixed Air System
In fully-stratified air distribution, cool supply air is typically
delivered at reduced velocity from low sidewall diffusers.
The supply air is always cooler than the room air, so it
quickly drops to the floor and moves slowly across the room.
When this slow moving air mass encounters a heat load, it
rises and carries the heat and pollutants towards the ceiling.
A layer of warm air forms above the occupied zone due to
natural buoyancy. Internal heat loads and contaminants are
carried away by the return air.

APPLICATION GUIDE

Displacement Ventilation

CONTAMINANT REMOVAL

Displacement ventilation can be a very effective strategy


for removing contaminants from room air, because fullystratified systems take advantage of the fact that airborne
pollutants are generally lighter than air. The natural
buoyancy of tobacco smoke and human respiration allow
these pollutants to rise above the breathing zone in plumes
to the upper zone that forms below the ceiling. This upward
migration of pollutants effectively increases concentrations
in the unoccupied upper zone while reducing concentrations
in the breathing zone.

Figure 4. Contaminant Distribution


in a Fully-Stratified System

www.titus-hvac.com | www.titus-energysolutions.com

TYPICAL APPLICATIONS

Ideal applications for displacement ventilation often involve


large open spaces with tall ceilings. These include but are
not limited to:
Theaters and performance halls
Meeting rooms and lecture halls
Restaurants and cafeterias
Hotel lobbies and atriums
Shopping malls
Gymnasiums
Casinos
Museums and exhibit halls
Classrooms
Airport terminals and train stations

BENEFITS AND LIMITATIONS

Typical benefits of displacement ventilation include:


Improved removal of airborne contaminants.
Greatly reduced energy requirements to
cool occupied spaces in mild climates.
Reduced ventilation air requirement due to
increased air distribution effectiveness.
Very low diffuser noise levels.
Reduced comfort complaints due to drafts.

Although displacement ventilation is well-suited for a wide


variety of applications, the following spaces may be better
served by mixed air systems:
Spaces with ceiling heights lower than 9 ft.
Spaces with occupied zone heat loads
in excess of 30 Btu/hr-ft2.
Spaces furnished with cubicles or other partitions.
Spaces with ceiling heights lower than 10 ft that may
be subject to significant room air disturbances.
Applications involving contaminants that are heavier
and/or colder than room air in the occupied zone.

ENERGY CONSIDERATIONS

A couple of important considerations:


Displacement ventilation is not recommended for
spaces where hazardous chemical spills could occur.
In the event of a spill, a displacement ventilation
system is likely to cause noxious fumes to be drawn
from the floor and brought up to the breathing level,
thereby increasing the possible hazard to occupants.
In rare situations where contaminants are heavier than
air, accommodations should be made to allow some
portion of the room air to be extracted at a lower level.

APPLICATION GUIDE

Figure 3. Contaminant Distribution in a Mixed Air System

Displacement ventilation can reduce energy use in several


ways:
Increased economizer hours due to increased
supply temperatures in comparison to
conventional mixed air systems.
Chiller efficiency increases due to lesser dehumidification
at higher water supply temperatures.

T9

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE

Displacement Ventilation

OUTLET CHARACTERISTICS

Displacement ventilation requires outlets that supply air


at extremely low velocities, (typically 50-70 fpm). These
outlets are typically located low on a sidewall or at the
base of a column. The low average face velocity generally
results in rather large diffuser panels. Since the outlets
are located adjacent to the occupied zone and within easy
reach of room occupants, they have the following special
requirements:
Should be elevated above the floor to prevent
damage from cleaning equipment.
Construction and finishes must be rugged
enough to prevent damage through accidental
or intentional occupant contact.
Should provide a concealed and tamperproof
means of air pattern adjustment.
Face panel must be removable for cleaning
and adjustment of air pattern controllers.

Figure 6. Standard Air Patterns

THE ADJACENT ZONE

The area immediately adjacent to a displacement ventilation


outlet is known as the adjacent zone. This is any area in
the occupied zone where local air velocities exceed 50 fpm
at a height 1 in above the floor. Although this clear zone can
often be in an aisle or corridor without creating potential
comfort problems, stationary occupants should never be
located within the adjacent zone. Cool air that drops from
a sidewall diffuser and travels across the floor can easily be
sensed by stationary occupants at the ankle level.

Figure 7. Adjusted Air Patterns

APPLICATION GUIDE

professionals for successful project integration. Generally


speaking, displacement diffusers can be ducted from above
or below or plenum-supplied.

Figure 5. The Adjacent Zone


It is important to note that all Titus displacement ventilation
diffusers are supplied with adjustable air pattern controllers
as standard equipment. The ability to adjust the shape of
the air pattern and the adjacent zone can be of great benefit
when dealing with furniture, occupants and obstructions
especially in smaller spaces.

OUTLET CHOICES

T10

Displacement ventilation diffusers are available in a wide


range of styles and sizes. Unlike conventional ceiling
diffusers, the size and placement of displacement ventilation
diffusers require early coordination with architectural

All Titus displacement diffusers include:


Adjustable air pattern controllers.
Air balancing tap.
Removable face plate.
All metal construction (galvanized steel and aluminum).
Standard #26 white powdercoat finish.
Optional telescoping duct cover (not applicable to DVR1).
Optional 2-3/4 or 4 inch mounting
base (not applicable to DVR1).

Displacement Ventilation
Convection plume

Return

Upper zone

Stratification

Lower zone

Supply
0
Temperature ,F

Heat/contaminant source

Figure 8.Heat Plume

HEAT SOURCES AND CONVECTIVE FLOWS

The flow of convective heat is essential in establishing a


fully-stratified system. As heat moves from warmer surfaces
to the cooler surrounding air, the buoyancy of the air
increases and the heat rises to create stratification in the
occupied zone. This upward air motion driven by convection
also results in room air entrainment that results in a larger
heat plume. Although radiant heat sources do not directly
affect these convective heat plumes, they may increase
plume formation by increasing surface temperatures of heat
sources.

AIR PATTERN PROJECTION

Although displacement ventilation is typically supplied from


a low sidewall, the resulting room pattern is very different
from a conventional sidewall grille. Because the supply air is
cooler than the room air and is discharging at low velocity,
it immediately drops to the floor. The air moves across the
floor in a thin layer typically no more than 6-8 inches high.
The diagrams above show why displacement ventilation is
only recommended for cooling applications.

www.titus-hvac.com | www.titus-energysolutions.com

Stratification
level

Setpoint

APPLICATION GUIDE

The characteristics of individual convective heat plumes may


be influenced by each of the following:
Size and shape of heat source
Amount of heat available
Air motion surrounding heat source
Temperature gradient in the space
Convective heat plumes will continue to rise until they reach
a room level of equal temperature.

SPACE TEMPERATURE GRADIENTS AND AIRFLOW RATES

The distance from the floor to the upper mixed zone is


known as the shift height. Since the design goal of a
displacement ventilation system is to create temperature
stratification throughout the occupied zone, it is critical that
the shift height is greater than height of the occupied zone.
Lower shift heights may be acceptable in situations where
all occupants are seated.

Figure 9. Discharge Air Patterns


This air pattern tends to stretch out and cover the entire
room, even if the room shape is irregular. Obstructions such
as partitions or furniture resting directly on the floor can
result in coverage gaps, but the air pattern will rejoin itself
much like fluid passing around an object.
Displacement diffusers can typically provide coverage into
a room that is up to six times the length of the adjacent
zone. Internal heat load concentrations actually help to
extend the projection of a displacement system by drawing
the air across the room. Large rooms can be supplied from
the side walls so long as the distance from the diffuser
face to the furthest projection is no more than 30 ft. When
room dimensions exceed 30 ft in length or width, it is best
to place displacement diffusers on more than one wall. By
placing diffusers on opposing walls, rooms up to 60 ft can
be supplied from side walls. Another solution for large rooms
is to place 360-degree diffusers throughout the interior
space.

APPLICATION GUIDE

Displacement ventilation diffusers supply conditioned air at


higher cooling temperatures (typically 62 to 70F) and lower
discharge velocities (less than 70 fpm) than ceiling diffusers.
Since the supply air is always cooler than the room air, it
can be said to cascade from the diffuser face to the floor.
The negative buoyancy of the cooler air causes it to move
at the floor level until it reaches a source of convective heat.
As the supply air warms, its buoyancy increases to create
a heat plume that rises to the upper mixed zone below the
ceiling.

T11

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE
METHODS OF EVALUATION

A successful displacement ventilation design should


provide a supply airflow rate to meet the thermal
gradient profile of an occupied space in accordance with
ASHRAE comfort guidelines. ASHRAE Standard 55-2010
Thermal Environmental Conditions for Human Occupancy
recommends that vertical temperature differential between
a seated occupants ankle and head regions (roughly 4 to
43 in) should be no more than 5.4F to deliver acceptable
comfort to 95% or more of the occupants. For a stationary
standing person same guideline would apply over an
elevation range of 4 to 67 in.

Displacement Ventilation
low velocity and therefore do not generate audible noise.
The catalog sound performance rating of a displacement
diffuser is usually expressed in terms of a noise criteria (NC)
level based upon a typical space with room absorption of
10 dB in each octave band per ASHRAE Standard 70-2006
(Appendix D).
While this typical space effect has been used for many
years to estimate the sound level of a diffuser serving a
small office, this certainly isnt the typical environment in
which displacement ventilation is employed. Since we are
often dealing with much larger spaces and taller ceilings,
a different method must be employed to better estimate
sound levels. A space effect for each octave band can be
calculated based upon the size of the room and the distance
between the source and observer using the following
equation per AHRI Standard 885-2008:
Space Effect = 25 10 log (ft) 5 log (ft3) 3 log (Hz)
Where:

ft = Distance between the source and observer


ft3 = Room volume
Hz = Octave band center frequency

Figure 10. Maximum Temperature Differentials


for Acceptable Thermal Comfort

APPLICATION GUIDE

SUPPLY AIR CONNECTIONS

T12

Displacement ventilation diffusers are usually supplied by


ductwork and they can be supplied from either above or
below.
Optional telescoping duct covers are available
to hide otherwise visible supply ductwork
for a clean finished appearance.
Optional mounting bases (2-3/4 or 4 inch) are
recommended to prevent possible damage due
to traffic and floor cleaning equipment. These
mounting bases are also recommended to simplify
installation when air will be supplied from below.
It is also possible to supply displacement ventilation
diffusers from a pressurized plenum.
Care must be taken to insure that the
supply plenum is tightly sealed.
In a properly designed supply plenum,
pressures should be equal throughout and
balancing dampers should not be required.

ACOUSTICAL PERFORMANCE

Like any building space, those supplied by displacement


ventilation create an acoustical environment with
contributions from air handlers, terminal units, diffusers
and structure-borne sound. Properly sized and selected
displacement ventilation diffusers are rarely the cause of
noise complaints because they operate at low pressure and

When considering sound contributions from multiple


diffusers, we can logarithmically add or multiply, but this
is typically unnecessary. In large spaces, diffusers are
rarely close enough together to contribute to the overall
room sound level. As a general rule for smaller spaces, it is
advisable to select diffusers for an NC level that is 10 points
lower than the desired room sound level. This has the effect
of masking the sound contribution of the diffusers in the
background sound level. For larger spaces, the NC level
of the diffuser is less critical because the room effect is so
much greater.

DISPLACEMENT VENTILATION THEORY AND GOVERNING


EQUATIONS

The following material is based on ASHRAE research


project RP-949 that resulted in the ASHRAE publication
System Performance Evaluation and Design Guidelines
for Displacement Ventilation (2003). This summary is
intended to briefly explain the theory behind displacement
ventilation. For a more detailed explanation including the
derivation of each equation, the original publication is highly
recommended.
The design air volume supplied by a displacement
ventilation system must be capable of meeting both the
cooling and minimum ventilation requirements for a given
space. In order to determine the cooling design air volume,
the type, location and magnitude of all heat loads must be
identified. These loads can be classified as:
Heat generated by occupants, desk lamps
and office equipment, Qoe (Btu/h)
Heat generated by overhead lighting, Ql (Btu/h)
Heat from the exterior wall and window surfaces
including transmitted solar radiation, Qex (Btu/h)

APPLICATION GUIDE

Displacement Ventilation

The heat transfer to the region of interest can therefore be


calculated by the following equation:
Thf CpV = oeQoe + lQl + exQex

Vh = (0.295Qoe + 0.132Ql + 0.185Qex)/(Thf Cp)


With the following assumptions:
Thf = 3.6 F (for a seated occupant)
= 0.075 lb/ft2
Cp = 0.24 Btu/lb-F
This equation can be simplified to:
Vh = 0.076Qoe + 0.034Ql + 0.048Qex
This equation is very useful for typical applications involving
seated occupants.

Where:
Thf = temperature differential between the
head and foot level of occupant (F)
= air density under standard conditions (lb/ft3)
Cp = specific heat of air at constant pressure (Btu/lb-F)
V = supply flow rate (ft3/h)

The required ventilation rate can be determined by


consulting ASHRAE Standard 62.1-2010. This standard
provides recommended ventilation rates for various
room occupancies and applications (Table 6-1). These
recommendations involve the minimum ventilation rates in
the breathing zone based upon both occupant density and
floor area.

Since:

The breathing zone outdoor airflow (cfm), Vbz, can be


calculated using the following equation:

V = nHA
Where:
n = the required air change rate (ach)
H = space height (ft)
A = floor area (ft2)
The heat transfer equation can be simplified to:
Thf = (oeQoe + lQl + exQex ) / (CpnHA)

The same equation can be used to calculate the required


ventilation rate:
n = (oeQoe + lQl + exQex ) / (Thf CpHA)
The cooling air volume (cfm), Vh, for a typical office
environment can then be calculated using the following
equation:
Vh = nAH/60

Vbz = (Rp x Pz ) + (Ra x Az )


Where:
Rp = people outdoor air rate from Table 6-1 (cfm/person)
Pz = zone population (#)
Ra = area outdoor air rate from Table 6-1 (cfm/ft2)
Az = zone floor area (ft2)
ASHRAE Standard 62.1-2010 also defines air change
effectiveness (Ez) of various types of air distribution systems
(Table 6-2). While the best mixed air system with ceiling
diffusers can only achieve a rating of 1.0, displacement
ventilation systems achieve a 1.2 rating. This means that
a displacement ventilation system can meet ventilation
requirements with 16.7% less air volume than a mixed air
system. Be aware that local code requirements may be more
stringent than the minimum standards recommended by
ASHRAE and may not differentiate between system types
and air change effectiveness.

Where:
Ez = air change effectiveness from Table 6-2

APPLICATION GUIDE

ASHRAE Standard 55-2010 recommends that for good


thermal comfort the temperature difference between the
head and foot level of a standing person should not exceed
5.4 F. In a stratification zone, assume that the temperature
gradient will be less than 1 F/ft. Since the vertical
temperature gradient between a seated persons head
(3.6 ft) and a standing persons head (5.6 ft) is generally
less than that between the ankle level (0.3 ft) and seated
persons head (3.6 ft), any design that meets the seated
recommendations should also be suitable for a standing
person.

www.titus-hvac.com | www.titus-energysolutions.com

Substituting the ventilation rate, n, into the equation yields:


A weighting factor must be applied to each of these loads
to properly approximate the effect of each type of load
entering the region between the head and the feet of
a seated occupant. Based on ASHRAE research, these
weighting factors are:
Occupants, desk lamps and office equipment, oe = 0.295
Overhead lighting, l = 0.132
Exterior wall and window surfaces including
transmitted solar radiation, ex = 0.185

The supply air volume (cfm), V, will be larger of either the


cooling air volume (cfm), Vh, or the zone outdoor airflow
requirement (cfm), Voz. Be aware that if a dedicated outdoor
air system (DOAS) is employed, then supply air volume,
V, would consist of 100% outdoor air. If return air is being

T13

The zone outdoor airflow requirement (cfm), Voz, can be


calculated as:
Voz = Vbz / Ez

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE

mixed with outdoor air, supply air volume, V, must contain


enough outdoor air to meet the zone outdoor requirement,
Voz.

internal heat loads greater than 30 Btu/ft2.

The supply air temperature, Ts, is always cooler than the


room temperature, Tsp, and can be calculated by based on
the air temperature at the floor level, Tf.

A=LxW

Tf = Tsp - Thf
And:
Ts = Tf fQt / (60CpV)
Where:
f = dimensionless temperature calculated
by Mundts formula (1992)
Qt = total cooling load in space (Btu/h)
V = supply air volume (cfm)
f = 1 / ((60VCp / A)((1/r ) + (1/cf )) + 1)
Where:
r = radiant heat transfer from ceiling to floor (Btu/h-ft2-F)
cf = convective heat transfer from floor
surface to the room air (Btu/h-ft2-F)

Where:
A = floor area (ft2)
L = room length (ft)
W = room width (ft)
Step 3 Calculate the Cooling Air Volume
The cooling air volume, Vh, can be determined from heat
loads with weighting factors applied:
Vh = 0.076Qoe + 0.034Ql + 0.048Qex
Step 4 Calculate the Zone Outdoor Airflow for Acceptable
Indoor Air Quality
The zone outdoor airflow requirement (cfm), Voz, and the
breathing zone outdoor airflow (cfm), Vbz, can be determined
from ASHRAE Standard 62.1 (Tables 6-1 and 6-2) and the
following equations:
Vbz = (Rp x Pz ) + (Ra x Az )

Ts = Tsp 3.6 ((AQt )/(2.59V2 + 1.08 AV))


The exhaust air temperature, Te, can be calculated as:

Voz = Vbz / Ez

Te = Ts + ((Qt )/(1.08V))

Where:
Ez = air change effectiveness from Table 6-2 = 1.2

DESIGN PROCEDURE FOR DISPLACEMENT


VENTILATION

APPLICATION GUIDE

Qt / A 30 Btu/ft2

Where:
Rp = people outdoor air rate from Table 6-1 (cfm/person)
Pz = zone population (#)
Ra = area outdoor air rate from Table 6-1 (cfm/ft2)
Az = zone floor area (ft2)

Assuming that heat transfer coefficients r and cf are equal


to 0.9 Btu/(h-ft2-F) and that Thf should be less than 3.6BF for
a seated occupant, this equation can then be simplified to:

T14

Displacement Ventilation

The following design procedure is patterned on that


provided in an ASHRAE publication entitled System
Performance and Design Guidelines for Displacement
Ventilation (2003). It was developed based upon the finding
of ASHRAE Research Project RP-949.
Step 1 Calculate the Total Cooling Load
The total cooling load, Qt, is the sum of the heat loads:
Qt = Qoe + Ql + Qex
Where:
Qoe = Heat generated by occupants, desk
lamps and office equipment (Btu/h)
Ql = Heat generated by overhead lighting (Btu/h)
Qex = Heat from the exterior wall and window surfaces
including transmitted solar radiation (Btu/h)
Step 2 Check for Excessive Heat Load
Displacement ventilation is generally not recommended for

Step 5 Determine the Supply Air Volume


The supply air volume, V, will be larger of either the cooling
air volume, Vh, or the zone outdoor airflow requirement, Voz.
Step 6 Calculate the Supply Air Temperature
The supply air temperature, Ts, can be calculated as:
Ts = Tsp 3.6 ((AQt )/(2.59V2 + 1.08 AV))
Where:
Tsp = room temperature (F)
Step 7 Calculate the Exhaust Air Temperature
The exhaust air temperature, Te, can be calculated as:
Te = Ts + ((Qt )/(1.08V))
Step 8 Select Supply Diffuser(s)

APPLICATION GUIDE
This a small private office measuring 12 ft by 10 ft by 9 ft (L
x W x H). The office is equipped with a computer, a monitor,
a small printer and a desk lamp. The 12 ft long wall includes
exterior glass. The room will be supplied by a dedicated
outdoor air system (DOAS).
Assume:
Occupancy = 1
Load per person = 250 Btu/h
Overhead lighting load = 2 watts/ft2 = 6.826 Btu/h-ft2
Computer load = 65 watts = 222 Btu/h
Monitor load = 30 watts = 102 Btu/h
Small printer load = 30 watts = 102 Btu/h
Desk lamp load = 40 watts = 137 Btu/h
Solar and glass load = 4.0 Btu/h-ft2

breathing zone outdoor airflow (cfm), Vbz, can be determined


from ASHRAE Standard 62.1 (Tables 6-1 and 6-2) and the
following equations:
Vbz = (Rp x Pz ) + (Ra x Az )
Where:
Rp = people outdoor air rate from
Table 6-1 = 5.0 cfm/person
Pz = zone population (#) = 1
Ra = area outdoor air rate from Table 6-1 = 0.06 cfm/ft2
Az = zone floor area (ft2)
Vbz = 12.2 cfm
Voz = Vbz / Ez

Step 1 Calculate the Total Cooling Load


Qt = Qoe + Ql + Qex
Where:
Qoe = Heat generated by occupants, desk
lamps and office equipment (Btu/h)
Ql = Heat generated by overhead lighting (Btu/h)
Qex = Heat from the exterior wall and window surfaces
including transmitted solar radiation (Btu/h)

Where:
Ez = air change effectiveness from Table 6-2 = 1.2
Voz = 10.2 cfm
Step 5 Determine the Supply Air Volume
The supply air volume, V, will be larger of either the cooling
air volume, Vh, or the zone outdoor airflow requirement, Voz.

Qoe = person + computer + monitor + small printer + desk


lamp = 813 Btu/h
Ql = overhead lighting load x floor area = 819 Btu/h
Qex = solar and glass load x exterior wall area = 432 Btu/h

V = 110 cfm

Qt = 2064 Btu/h

Ts = Tsp 3.6 ((AQt )/(2.59V2 + 1.08 AV))

Step 2 Check for Excessive Heat Load


Displacement ventilation is generally not recommended for
internal heat loads greater than 30 Btu/ft2.
Qt / A 30 Btu/ft2
A=LxW

Qt / A = 17.2 Btu/ft2
Step 3 Calculate the Cooling Air Volume
The cooling air volume, Vh, can be determined from heat
loads with weighting factors applied:
Vh = 0.076Qoe + 0.034Ql + 0.048Qex
Vh = 110 cfm
Step 4 Calculate the Zone Outdoor Airflow for Acceptable
Indoor Air Quality
The zone outdoor airflow requirement (cfm), Voz, and the

Step 6 Calculate the Supply Air Temperature


The supply air temperature, Ts, can be calculated as:

Where:
Tsp = room temperature = 72 F
Ts = 63 F
Step 7 Calculate the Exhaust Air Temperature
The exhaust air temperature, Te, can be calculated as:
Te = Ts + ((Qt )/(1.08V))
Te = 80 F
Step 8 Select Supply Diffuser(s)
The best diffuser for this application would be a single flushmounted wall unit handling 110 cfm. It should ideally be
located away from the desk on an opposite wall discharging
parallel to the window. Care should be taken in a space
this size to ensure that the depth of the adjacent zone is
less than 3-4 ft. Since the sound level in a private office is
recommended not to exceed a sound level of NC35, the
diffuser should be selected for NC25 or less. See Figure 11 for
example of diffuser layout.

APPLICATION GUIDE

Where:
A = floor area (ft2)
L = room length (ft)
W = room width (ft)

www.titus-hvac.com | www.titus-energysolutions.com

DESIGN EXAMPLE - PRIVATE PERIMETER OFFICE

Displacement Ventilation

T15

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE

Where:
A = floor area (ft2)
L = room length (ft)
W = room width (ft)
Qt / A = 17.2 Btu/ft2
Step 3 Calculate the Cooling Air Volume
The cooling air volume, Vh, can be determined from heat
loads with weighting factors applied:

Figure 11. Design Example - Private Perimeter Office

DESIGN EXAMPLE - OPEN PLAN INTERIOR OFFICE


This is an open plan office for customer service
representatives. The office is furnished with workstations to
accommodate up to sixteen employees and measures 40 ft
by 40 ft by 12 ft (L x W x H). Each workstation is equipped
with a computer, a monitor and a desk lamp. There is also a
single large printer that is shared. The room will be supplied
by a conventional air handler that will mix return air with
outdoor air.
Assume:
Occupancy = 16
Load per person = 250 Btu/h
Overhead lighting load = 2 watts/ft2 = 6.826 Btu/h-ft2
Computer load = 65 watts = 222 Btu/h
Monitor load = 30 watts = 102 Btu/h
Large printer load = 110 watts = 375 Btu/h
Desk lamp load = 40 watts = 137 Btu/h

APPLICATION GUIDE

Step 1 Calculate the Total Cooling Load


Qt = Qoe + Ql + Qex

Vh = 0.076Qoe + 0.034Ql + 0.048Qex


Vh = 1264 cfm
Step 4 Calculate the Zone Outdoor Airflow for Acceptable
Indoor Air Quality
The zone outdoor airflow requirement (cfm), Voz, and the
breathing zone outdoor airflow (cfm), Vbz, can be determined
from ASHRAE Standard 62.1 (Tables 6-1 and 6-2) and the
following equations:
Vbz = (Rp x Pz ) + (Ra x Az )
Where:
Rp = people outdoor air rate from
Table 6-1 = 5.0 cfm/person
Pz = zone population (#) = 16
Ra = area outdoor air rate from Table 6-1 = 0.06 cfm/ft2
Az = zone floor area (ft2)
Vbz = 176 cfm
Voz = Vbz / Ez
Where:
Ez = air change effectiveness from Table 6-2 = 1.2

Where:
Qoe = Heat generated by occupants, desk
lamps and office equipment (Btu/h)
Ql = Heat generated by overhead lighting (Btu/h)
Qex = Heat from the exterior wall and window surfaces
including transmitted solar radiation (Btu/h)

Voz = 147 cfm

Qoe = (16) people + (16) computers + (16) monitors + (1)


large printer + (16) desk lamps = 11751 Btu/h
Ql = overhead lighting load x floor area = 10922 Btu/h
Qex = 0 Btu/h

V = 1264 cfm

Qt = 22673 Btu/h
Step 2 Check for Excessive Heat Load
Displacement ventilation is generally not recommended for
internal heat loads greater than 30 Btu/ft2.
Qt / A 30 Btu/ft2
A=LxW

T16

Displacement Ventilation

Step 5 Determine the Supply Air Volume


The supply air volume, V, will be larger of either the cooling
air volume, Vh, or the zone outdoor airflow requirement, Voz.

Since the air handler will be mixing return air with outdoor
air, we must calculate the required percentage of outdoor air
to satisfy the zone outdoor air requirement, Voz.
Voz / V = 12%
Step 6 Calculate the Supply Air Temperature
The supply air temperature, Ts, can be calculated as:
Ts = Tsp 3.6 ((AQt )/(2.59V2 + 1.08 AV))

APPLICATION GUIDE

Ts = 65 F
Step 7 Calculate the Exhaust Air Temperature
The exhaust air temperature, Te, can be calculated as:
Te = Ts + ((Qt )/(1.08V))
Te = 81 F
Step 8 Select Supply Diffuser(s)
There are many different diffuser selections that could work
well in this space. Flat front or bow-fronted diffusers either
flush-mounted or surface-mounted would be best. The exact
model choice comes down to appearance and architectural
limitations. The best arrangement would be to place pairs of
diffusers on opposite walls such that they discharge down
the aisles between work stations. This would require four
diffusers each handling 316 cfm, selected for an adjacent
zone with a depth of less than 4-5 ft. This should be
adequate to achieve coverage to the center of the room.
Since the ideal sound level for an open plan office is NC40,
the diffusers should be selected for NC30 or less. See Figure
12 for example of diffuser layout.

Where:
Qoe = Heat generated by occupants, desk
lamps and office equipment (Btu/h)
Ql = Heat generated by overhead lighting (Btu/h)
Qex = Heat from the exterior wall and window surfaces
including transmitted solar radiation (Btu/h)
Qoe = (12) people + computer + projector = 3905 Btu/h
Ql = overhead lighting load x floor area = 3072 Btu/h
Qex = solar and glass load x exterior wall area = 1200 Btu/h
Qt = 8177 Btu/h
Step 2 Check for Excessive Heat Load
Displacement ventilation is generally not recommended for
internal heat loads greater than 30 Btu/ft2.

www.titus-hvac.com | www.titus-energysolutions.com

Where:
Tsp = room temperature = 74 F

Displacement Ventilation

Qt / A 30 Btu/ft2
A=LxW
Where:
A = floor area (ft2)
L = room length (ft)
W = room width (ft)

Qt / A = 18.2 Btu/ft2
Step 3 Calculate the Cooling Air Volume
The cooling air volume, Vh, can be determined from heat
loads with weighting factors applied:
Vh = 0.076Qoe + 0.034Ql + 0.048Qex
Vh = 459 cfm

Figure 12. Design Example - Open Plan Interior Office

DESIGN EXAMPLE - PERIMETER CONFERENCE


ROOM

Step 1 Calculate the Total Cooling Load


Qt = Qoe + Ql + Qex

Vbz = (Rp x Pz ) + (Ra x Az )


Where:
Rp = people outdoor air rate from
Table 6-1 = 5.0 cfm/person
Pz = zone population (#) = 1
Ra = area outdoor air rate from Table 6-1 = 0.06 cfm/ft2
Az = zone floor area (ft2)
Vbz = 87 cfm

APPLICATION GUIDE

This is a conference room with an exterior window. The


room is equipped with a computer and a projector and is
intended for a maximum occupancy of twelve. It measures
30 ft by 15 ft by 10 ft (L x W x H). The window is located
on the longest wall. The room will be supplied by a
conventional air handler that will mix return air with outdoor
air.
Assume:
Occupancy = 12
Load per person = 250 Btu/h
Overhead lighting load = 2 watts/ft2 = 6.826 Btu/h-ft2
Computer load = 65 watts = 222 Btu/h
Projector load = 200 watts = 683 Btu/h
Solar and glass load = 4.0 Btu/h-ft2

Step 4 Calculate the Zone Outdoor Airflow for Acceptable


Indoor Air Quality
The zone outdoor airflow requirement (cfm), Voz, and the
breathing zone outdoor airflow (cfm), Vbz, can be determined
from ASHRAE Standard 62.1 (Tables 6-1 and 6-2) and the
following equations:

Voz = Vbz / Ez
Where:
Ez = air change effectiveness from Table 6.2 = 1.2

T17

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE

Voz = 72.5 cfm


Step 5 Determine the Supply Air Volume
The supply air volume, V, will be larger of either the cooling
air volume, Vh, or the zone outdoor airflow requirement, Voz.
V = 459 cfm
Since the air handler will be mixing return air with outdoor
air, we must calculate the required percentage of outdoor air
to satisfy the zone outdoor air requirement, Voz.
Voz / V = 16%
Step 6 Calculate the Supply Air Temperature
The supply air temperature, Ts, can be calculated as:
Ts = Tsp 3.6 ((AQt )/(2.59V2 + 1.08 AV))
Where:
Tsp = room temperature = 72 F
Ts = 64 F
Step 7 Calculate the Exhaust Air Temperature
The exhaust air temperature, Te, can be calculated as:
Te = Ts + ((Qt )/(1.08V))
Te = 80 F
Step 8 Select Supply Diffuser(s)
The best choice for this application would be a pair of
90-degree air pattern diffusers located on the interior
corners of the room. Each diffuser will handle 230 cfm and
should be selected for an adjacent zone no deeper than
4-5 ft. Since the typical sound level for a conference room
should not exceed NC30, the diffusers should be selected for
NC20 or less. See Figure 13 for example of diffuser layout.

Displacement Ventilation
H). The room will be supplied by a conventional air handler
that will mix return air with outdoor air.
Assume:
Occupancy = 40
Load per person = 250 Btu/h
Overhead lighting load = 2 watts/ft2 = 6.826 Btu/h-ft2
Water cooler load = 350 watts = 1195 Btu/h
Coffee machine load = 1000 watts = 3413 Btu/h
Microwave oven load = 200 watts = 683 Btu/h
Ice maker load = 400 watts = 1365 Btu/h
Refrigerator load = 700 watts = 2389 Btu/h
Cold beverage machine load = 800 watts = 2730 Btu/h
Snack machine load = 250 watts = 853 Btu/h
Step 1 Calculate the Total Cooling Load
Qt = Qoe + Ql + Qex
Where:
Qoe = Heat generated by occupants, desk
lamps and office equipment (Btu/h)
Ql = Heat generated by overhead lighting (Btu/h)
Qex = Heat from the exterior wall and window surfaces
including transmitted solar radiation (Btu/h)
Qoe = (40) people + water cooler + coffee machine +
microwave oven + ice maker + refrigerator + cold beverage
machine + snack machine = 22628 Btu/h
Ql = overhead lighting load x floor area = 8737 Btu/h
Qt = 31365 Btu/h
Qex = 0 Btu/h
Step 2 Check for Excessive Heat Load
Displacement ventilation is generally not recommended for
internal heat loads greater than 30 Btu/ft2.
Qt / A 30 Btu/ft2

APPLICATION GUIDE

A=LxW
Where:
A = floor area (ft2)
L = room length (ft)
W = room width (ft)
Qt / A = 24.5 Btu/ft2

Figure 13. Design Example - Perimeter Conference Room

Vh = 0.076Qoe + 0.034Ql + 0.048Qex

DESIGN EXAMPLE - INTERIOR BREAKROOM

T18

Step 3 Calculate the Cooling Air Volume


The cooling air volume, Vh, can be determined from heat
loads with weighting factors applied:

This is a breakroom without windows. The room is equipped


with a water cooler, a coffee machine, a microwave oven,
an ice maker, a refrigerator, a cold beverage machine, and a
snack machine. It measures 40 ft by 32 ft by 12 ft (L x W x

Vh = 2017 cfm

APPLICATION GUIDE

336 cfm would result in shorter throws and smaller adjacent


zones. Sound levels in cafeterias and breakrooms are
seldom critical, but selecting the diffusers for NC25 or less is
advisable. See Figure 14 for example of diffuser layout

Vbz = (Rp x Pz ) + (Ra x Az )


Where:
Rp = people outdoor air rate from
Table 6-1 = 5.0 cfm/person
Pz = zone population (#) = 1
Ra = area outdoor air rate from Table 6-1 = 0.06 cfm/ft2
Az = zone floor area (ft2)
Vbz = 354 cfm

Figure 14. Design Example - Interior Breakroom

www.titus-hvac.com | www.titus-energysolutions.com

Step 4 Calculate the Zone Outdoor Airflow for Acceptable


Indoor Air Quality
The zone outdoor airflow requirement (cfm), Voz, and the
breathing zone outdoor airflow (cfm), Vbz, can be determined
from ASHRAE Standard 62.1 (Tables 6-1 and 6-2) and the
following equations:

Displacement Ventilation

Voz = Vbz / Ez
Where:
Ez = air change effectiveness from Table 6.2 = 1.2
Voz = 295 cfm
Step 5 Determine the Supply Air Volume
The supply air volume, V, will be larger of either the cooling
air volume, Vh, or the zone outdoor airflow requirement, Voz.
V = 2017 cfm
Since the air handler will be mixing return air with outdoor
air, we must calculate the required percentage of outdoor air
to satisfy the zone outdoor air requirement, Voz.
Voz / V = 15%
Step 6 Calculate the Supply Air Temperature
The supply air temperature, Ts, can be calculated as:
Ts = Tsp 3.6 ((AQt )/(2.59V2 + 1.08 AV))

Ts = 65 F
Step 7 Calculate the Exhaust Air Temperature
The exhaust air temperature, Te, can be calculated as:
Te = Ts + ((Qt )/(1.08V))
Te = 80 F
Step 8 Select Supply Diffuser(s)
There are many possible choices, but large open spaces
can be easily served with 360-degree air pattern diffusers
located away from the walls. Although four diffusers each
handling 504 cfm might work, six diffusers each handling

This is a school classroom with an exterior window. The


room is equipped with a computer and a projector and is
intended for a maximum occupancy of one teacher and (25)
students. The room is equipped with (5) computers, (5)
monitors and a projector. It measures 30 ft by 30 ft by 10 ft
(L x W x H). The room will be supplied by a conventional air
handler that will mix return air with outdoor air.
Assume:
Occupancy = 26
Load per person = 250 Btu/h
Overhead lighting load = 2 watts/ft2 = 6.826 Btu/h-ft2
Computer load = 65 watts = 222 Btu/h
Monitor load = 30 watts = 102 Btu/h
Projector load = 200 watts = 683 Btu/h
Solar and glass load = 10.5 Btu/h-ft2

Step 1 Calculate the Total Cooling Load


Qt = Qoe + Ql + Qex
Where:
Qoe = Heat generated by occupants, desk
lamps and office equipment (Btu/h)
Ql = Heat generated by overhead lighting (Btu/h)
Qex = Heat from the exterior wall and window surfaces
including transmitted solar radiation (Btu/h)
Qoe = (26) people + (5) computers + (5) monitors +
projector = 8803 Btu/h
Ql = overhead lighting load x floor area = 6143 Btu/h
Qex = solar and glass load x exterior wall area = 3150 Btu/h
Qt = 18096 Btu/h
Step 2 Check for Excessive Heat Load
Displacement ventilation is generally not recommended for
internal heat loads greater than 30 Btu/ft2.

APPLICATION GUIDE

Where:
Tsp = room temperature = 72 F

DESIGN EXAMPLE - ELEMENTARY SCHOOL


CLASSROOM

T19

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE
Qt / A 30 Btu/ft2
A=LxW
Where:
A = floor area (ft2)
L = room length (ft)
W = room width (ft)
Qt / A = 20.1 Btu/ft2
Step 3 Calculate the Cooling Air Volume
The cooling air volume, Vh, can be determined from heat
loads with weighting factors applied:
Vh = 0.076Qoe + 0.034Ql + 0.048Qex
Vh = 1029 cfm

Step 4 Calculate the Zone Outdoor Airflow for Acceptable


Indoor Air Quality
The zone outdoor airflow requirement (cfm), Voz, and the
breathing zone outdoor airflow (cfm), Vbz, can be determined
from ASHRAE Standard 62.1 (Tables 6-1 and 6-2) and the
following equations:
Vbz = (Rp x Pz ) + (Ra x Az )

Displacement Ventilation
Ts = Tsp 3.6 ((AQt )/(2.59V2 + 1.08 AV))
Where:
Tsp = room temperature = 74 F
Ts = 66 F
Step 7 Calculate the Exhaust Air Temperature
The exhaust air temperature, Te, can be calculated as:
Te = Ts + ((Qt )/(1.08V))
Te = 82 F
Step 8 Select Supply Diffuser(s)
Perimeter classrooms are typically arranged with the
instructors desk at one end of the room, the student desks
in rows facing the teacher and windows perpendicular desk
rows. The most common diffuser arrangement for this room
layout would require a diffuser on each side of the teachers
desk discharging down the side aisles. Each diffuser would
handle 515 cfm and the adjacent zone depth should be no
more than 4-5 ft. Since sound levels in elementary school
classrooms are critical to the learning environment and are
recommended not to exceed NC25-30, the diffusers should
be selected for NC15 or less so as not to be heard. See
Figure 15 for example of diffuser layout.

Where:
Rp = people outdoor air rate from
Table 6-1 = 5.0 cfm/person
Pz = zone population (#) = 1
Ra = area outdoor air rate from Table 6-1 = 0.06 cfm/ft2
Az = zone floor area (ft2)
Vbz = 368 cfm
Voz = Vbz / Ez

APPLICATION GUIDE

Where:
Ez = air change effectiveness from Table 6-2 = 1.2
Voz = 307 cfm
Step 5 Determine the Supply Air Volume
The supply air volume, V, will be larger of either the cooling
air volume, Vh, or the zone outdoor airflow requirement, Voz.
V = 1029 cfm
Since the air handler will be mixing return air with outdoor
air, we must calculate the required percentage of outdoor air
to satisfy the zone outdoor air requirement, Voz.
Voz / V = 30%

T20

Step 6 Calculate the Supply Air Temperature


The supply air temperature, Ts, can be calculated as:

Figure 15. Design Example - Elementary School Classroom

APPLICATION GUIDE

ASHRAE. 2011. 2011 ASHRAE Handbook-Applications, Chapter


57. Atlanta: American Society of Heating, Refrigerating and AirConditioning Engineers, Inc.
ASHRAE. 2010. ANSI/ASHRAE Standard 62.1-2010, Ventilation for
Acceptable Indoor Air Quality. Atlanta: American Society of Heating,
Refrigerating and Air-Conditioning Engineers, Inc.
ASHRAE. 2010. ANSI/ASHRAE Standard 55-2010, Thermal
Environmental Conditions for Human Occupancy. Atlanta: American
Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
ASHRAE. 2009. ANSI/ASHRAE Standard 113-2009, Method of
Testing for Room Air Diffusion. Atlanta: American Society of Heating,
Refrigerating and Air-Conditioning Engineers, Inc.
ASHRAE. 2009. 2009 ASHRAE Handbook-Fundamentals, Chapter
20. Atlanta: American Society of Heating, Refrigerating and AirConditioning Engineers, Inc.
AHRI. 2008. AHRI Standard 885-2008, Procedure for Estimating
Occupied Space Sound Levels in the Application of Air Terminals and
Air Outlets. Arlington, VA: Air-Conditioning, Heating, and Refrigeration
Institute, Inc.

www.titus-hvac.com | www.titus-energysolutions.com

References

Displacement Ventilation

Chen, Q., and L.R. Glicksman. 2003. System Performance Evaluation


and Design Guidelines for Displacement Ventilation. Atlanta: American
Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
REHVA. 2002. Displacement Ventilation in Non-Industrial Premises, ed.
Skistad, H. et al.

APPLICATION GUIDE
T21

Material is galvanized
steel and aluminum.

Available Model:
DVBC
Rectangular displacement diffuser with
curved face for wall mount applications.

Standard finish is #26


white (powdercoat).

Designed to supply a large volume of air


at low velocity to the occupied zone.

Mounting base and


telescopic duct
cover are available
as accessories.

Includes integral variable air pattern controllers for


easy adjustment of the airflow spread pattern.

DVBC

www.titus-hvac.com | www.titus-energysolutions.com

Displacement Ventilation

Rectangular Displacement
DVBC

Includes air volume measurement outlet to


facilitate balancing. K-factor is marked on outlet.

D
G

A
H

DVBC

Model Inlet Size

DVBC

T22

8
10
12
16
24 x 8
24 x 12

Nominal
Unit Size
36
36
36
36
36
36

x
x
x
x
x
x

37
37
60
39
39
39

A
B
35 7/16 36 5/16
35 7/16 36 5/16
35 7/16
60
35 7/16 78 7/8
35 7/16 78 7/8
35 7/16 78 7/8

Unit Dimensions (inches)


C
D
E
F
13 3/8
7 7/8
N/A
N/A
15 3/8
9 7/8
N/A
N/A
18
11 7/8
N/A
N/A
21 1/4 15 7/8
N/A
N/A
13 3/8
N/A
23 7/8
7 7/8
18
N/A
23 7/8 11 7/8

All dimensions are in inches.

G
6 1/4
7 1/4
8 1/2
10 3/16
7 1/8
5 1/16

3
3
3
3

H
1
/4
1
/4
1
/4
1
/4
2
2

Displacement Ventilation

ACCESSORIES

www.titus-hvac.com | www.titus-energysolutions.com

Optional telescopic duct cover

View with face removed showing integral


variable air pattern controllers

*Does not include mounting base height.

Unit Size

Diffuser height with


duct cover kit*
Min
Max

Optional mounting base


Height (J): 2-3/4 or 4

OptionalonMounting
Base the adjacent zone
For detailed instructions
how to change
Height
(J): 2-3/4"
or 4" refer to page T77.
using the variable
air pattern
controllers,

*Does not Include Mounting Base Height.

36 x 37

36 x 37

92 1/8

36 x 60

124

36 x 79

ACCESSORIES

36 x 79

109 7/8

36 x 79

*Height dimensions do not


include mounting base.

All dimensions are in inches.

T23

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DVBC
Unit Size
(W x H)

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

68
0.003
2-5
2-6
106
0.004
3-7
3-8
154
0.003
4-9
4-10
275
0.004
6-13
6-15
261
0.005
6-14
7-16
394
0.006
8-18
8-20

101
0.007
3-7
3-8
160
0.009
4-10
4-11
231
0.007
5-12
5-14
412
0.009
8-18
8-20
392
0.010
9-19
9-21
591
0.013
11-24
12-27

135
0.012
4-9
4-10
213
0.016
5-12
5-13
308
0.013
6-15
7-17
550
0.016
10-22
11-25
522
0.018
11-23
12-26
788
0.024
14-30
15-33

169
0.019
4-10
5-11
266
0.025
6-14
6-15
385
0.020
8-18
8-20
687
0.025
12-26
13-29
653
0.029
13-28
14-31
984
0.037
17-36
18-39

203
0.027
5-12
5-13
319
0.036
7-16
7-18
461
0.029
9-20
10-22
825
0.037
14-30
15-33
783
0.041
16-32
17-35
1181
0.054
12
20-41
21-45

237
0.036
6-13
6-14
372
0.049
8-18
8-20
538
0.039
10-23
11-25
962
0.050
10
16-34
17-37
914
0.056
12
18-35
19-39
1378
0.073
16
23-46
24-50

271
0.047
6-14
7-16
425
0.064
10
9-20
9-22
615
0.052
12-25
12-28
1100
0.065
14
18-37
19-41
1045
0.074
16
20-39
21-43
1575
0.096
20
26-50
27-56

Inlet Size

36 x 37

8 Dia

36 x 37

10 Dia

36 x 60

12 Dia

36 x 79

16 Dia

36 x 79

24 x 8

36 x 79

24 x 12

PERFORMANCE DATA

PERFORMANCE NOTES:

T24

The adjacent zone (AZ) is the discharge isovel at 1


above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.

DVBC

DT is the under temperature which is the difference


between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.
Throw values shown are distances in feet for
temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

Displacement Ventilation

SUGGESTED SPECIFICATIONS

Rectangular displacement diffusers shall be Titus model


DVBC of the sizes and mounting types shown on the plans
and outlet schedule. DVBC diffusers shall have a curved
front face plate and provide a 180 degree air discharge
pattern from the face and sides of diffuser. Diffusers
shall include integral variable air pattern controllers for
adjustment of airflow spread pattern. Air pattern controllers
shall be adjustable, reversible, and removable. Diffusers
shall include an air volume measurement outlet to facilitate
balancing. K-factor shall be marked on diffuser. Diffusers
shall include an internal perforated baffle to equalize airflow
across the face. Internal perforated baffle shall be round
perforated galvanized metal with 51% free area.
DVBC diffusers shall have a perforated face plate with
round perforations. Diffuser face plate shall be removable
for easy access to internal air pattern controllers.

Diffuser face plate, side plates, back panel, top panel,


bottom panel, and air pattern controllers plate shall be
constructed of galvannealed material. Internal perforated
baffle shall be constructed of G-90 22 gauge galvanized
metal material.
The finish shall be #26 white powdercoat paint with a
baked on finish. Paint thickness shall be 2.5 3.5 mils.
Paint must pass the ASTM D 3363 pencil hardness test with
a minimum pencil hardness of H 2H. The paint must pass
a 1000 hour ASTM B117-97 Corrosive Environments Salt
Spray test without creepage, blistering, or deterioration
of film. The paint must pass the adhesion cross hatch test
ASTM D 3359.
Optional accessories shall include telescopic duct cover and
mounting base.
The manufacturer shall provide published performance data
for DVBC displacement diffusers. Diffusers shall be tested in
accordance with European standard Nordtest method.

www.titus-hvac.com | www.titus-energysolutions.com

Available Model:
DVBC

MODEL NUMBER SPECIFICATION

Model
DVBC
XXXX

36
32
16
12
10
8
XX
Inlet Size

24 x 12 inlet
24 x 8 inlet

Unit Size

Finish

MB2
MB1
DC
O

XXXXX

XX

XXX

36 x 37

26
X

16 inlet
12 inlet
10 inlet
8 inlet

36 x 60

White

Mounting Base 4
Mounting Base 2 3/4
Duct Cover
None

Accessories

Special

36 x 79

SPECIFICATIONS
T25

Displacement Ventilation

DVIR
pattern controllers for easy
adjustment of the airflow spread
pattern.

Available Model:
DVIR
Rectangular displacement
diffuser with 1-way
discharge designed for flush
mount applications.

Includes air volume


measurement outlet to
facilitate balancing. K-factor
is marked on outlet.

Designed to supply small to


medium volumes of air at low
velocity to the occupied zone.

Material is galvanized
steel and aluminum.

Includes integral variable air

Optional duct cover


(fixed length: 78-3/4)

DVIR

www.titus-hvac.com | www.titus-energysolutions.com

Rectangular Displacement (continued)

Standard finish is #26


white (powdercoat).

1
2"
3
13 4 "

DVIR

T26

All dimensions are in inches.

Displacement Ventilation

Rectangular Displacement (continued)

Model

Inlet Size

DVIR

6x2
6x2
10 x 2
10 x 2
10 x 2
10 x 2
12 x 2
14 x 2
14 x 2
14 x 2
20 x 3
20 x 3
20 x 3
20 x 3
20 x 3
20 x 3
20 x 3
20 x 3
24 x 3

Nominal
Unit Size
12 x 10
12 x 12
16 x 10
16 x 12
16 x 16
16 x 24

A
12
12
16
16
16
16

B
10
12
10
12
16
24

20 x 20
24 x 12
24 x 18
24 x 24
24 x 30
24 x 36
24 x 48
30 x 24
36 x 12
36 x 24
48 x 12
48 x 24
60 x 24

20
24
24
24
24
24
24
30
36
36
48
48
60

20
12
18
24
30
36
48
24
12
24
12
24
24

Unit Dimensions (inches)


C
E
F
5 7/8
1 7/8
3 1/8
3 1/8
5 7/8
1 7/8
3 1/8
9 7/8
1 7/8
3 1/8
9 7/8
1 7/8
3 1/8
9 7/8
1 7/8
3 1/8
9 7/8
1 7/8
3 1/8
11 7/8
1 7/8
3 1/8
13 7/8
1 7/8
3 1/8
13 7/8
1 7/8
13 7/8
1 7/8
3 1/8
4
19 7/8
2 7/8
4
19 7/8
2 7/8
4
19 7/8
2 7/8
4
19 7/8
2 7/8
4
19 7/8
2 7/8
4
19 7/8
2 7/8
4
19 7/8
2 7/8
4
19 7/8
2 7/8
4
23 7/8
2 7/8

G
9 11/16
9 11/16
13 11/16
13 11/16
13 11/16
13 11/16
17 7/16
21 11/16
21 11/16
21 11/16
21 11/16
21 11/16
21 11/16
27 11/16
33 11/16
33 11/16
45 11/16
45 11/16
57 11/16

H
7 13/16
9 13/16
7 13/16
9 13/16
13 13/16
21 13/16
17 13/16
9 13/16
16
21 13/16
27 13/16
33 13/16
45 13/16
21 13/16
9 13/16
21 13/16
9 13/16
21 13/16
21 13/16

www.titus-hvac.com | www.titus-energysolutions.com

DVIR UNIT DIMENSIONS

DVRI
T27

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

ACCESSORIES

Optional telescopic duct cover

78 3/4"

ACCESSORIES

View with face removed showing integral


variable air pattern controllers

T28

Model

Inlet
Size

DVIR

8
12
14
16
23
27

D
3 7/8
3 7/8
4 7/8
5 7/8
7 7/8
9 7/8

Inlet Dimensions (inches)


J
L
2 7/8
6 1/16
2 7/8
10 1/16
7
3 /16
12 1/16
1
4 /8
14 1/16
15
4 /16
20 1/16
15
5 /16
24 1/16

For detailed instructions on how to change the adjacent zone


using the variable air pattern controllers, refer to page T77.

All dimensions are in inches.

N
2
2
2
2
3
3

Displacement Ventilation

PERFORMANCE DATA

Unit Size
(W x H)

200

300

400

500

600

700

800

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

26
0.008
2-3
2-4
26
0.005
2-3
2-4
32
0.005
2-3
3-4
37
0.004
2-3
3-4
80
0.007
3-7
4-8
80
0.005
3-7
4-8

39
0.019
2-5
3-6
39
0.011
2-5
3-6
47
0.012
2-5
3-6
55
0.009
3-5
4-6
121
0.017
4-11
5-12
121
0.012
4-11
5-12

53
0.034
2-7
3-7
53
0.019
2-7
3-7
63
0.021
3-7
4-7
74
0.017
3-7
4-8
161
0.030
5-14
6-16
161
0.022
5-14
6-16

66
0.053
10
3-8
3-9
66
0.030
3-8
3-9
79
0.033
3-8
4-9
92
0.026
4-8
5-9
201
0.047
12
5-18
7-20
201
0.034
11
5-18
7-20

79
0.076
16
3-10
4-11
79
0.043
14
3-10
4-11
95
0.048
15
3-10
4-11
111
0.038
14
4-10
5-11
241
0.068
17
6-21
7-23
241
0.049
16
6-21
7-23

92
0.103
21
3-11
4-13
92
0.059
19
3-11
4-13
111
0.066
20
4-12
5-13
129
0.051
19
4-12
5-13
282
0.093
22
6-25
8-27
282
0.067
21
6-25
8-27

105
0.135
25
3-13
4-14
105
0.076
23
3-13
4-14
126
0.085
24
4-13
5-14
148
0.067
23
5-13
6-15
322
0.121
26
7-28
8-31
322
0.087
25
7-28
8-31

20 x 3

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

80
0.004
3-7
4-8

121
0.009
4-11
5-12

161
0.017
5-14
6-16

201
0.026
10
5-18
7-20

241
0.037
15
6-21
7-23

282
0.051
20
6-25
8-27

322
0.066
24
7-28
8-31

20 x 3

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

80
0.007
4-6
5-7

121
0.017
5-9
6-10

161
0.030
5-12
6-13

201
0.047
12
6-15
7-17

241
0.068
17
6-18
8-20

282
0.093
22
7-21
8-23

322
0.121
26
7-23
9-26

20 x 3

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

80
0.005
4-5
5-6

121
0.012
5-8
6-9

161
0.022
6-10
7-12

201
0.034
11
6-13
8-14

241
0.049
16
7-15
8-17

282
0.067
21
7-18
9-20

322
0.087
25
8-20
10-23

16 x 16

10 x 2

16 x 24

10 x 2

20 x 20

12 x 2

24 x 24

14 x 2

24 x 30

20 x 3

24 x 36

20 x 3

24 x 48

30 x 24

36 x 24

PERFORMANCE DATA

Neck Velocity
Velocity Pressure

Inlet Size

www.titus-hvac.com | www.titus-energysolutions.com

DVIR

T29

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DVIR (continued)
Unit Size
(W x H)

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

80
0.004
4-4
6-5
97
0.004
5-4
7-5

121
0.010
5-6
7-7
145
0.009
6-6
8-7

161
0.018
6-8
8-9
193
0.016
7-8
9-9

201
0.028
10
7-10
9-11
242
0.025
10
8-10
10-12

241
0.040
16
7-12
9-14
290
0.036
15
9-12
11-14

282
0.055
20
8-14
10-16
338
0.049
20
10-14
12-16

322
0.071
25
9-16
11-18
387
0.064
24
10-16
13-18

Inlet Size

48 x 24

20 x 3

60 x 24

24 x 3

PERFORMANCE NOTES:
The adjacent zone (AZ) is the discharge isovel at 1
above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
DT is the under temperature which is the difference
between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.

PERFORMANCE DATA

T30

DVIR

Throw values shown are distances in feet for


temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

Displacement Ventilation

SUGGESTED SPECIFICATIONS

Rectangular displacement diffusers shall be Titus model


DVIR of the sizes and mounting types shown on the plans
and outlet schedule. DVIR diffusers shall provide a 1-way air
discharge pattern from the face of diffuser for flush mount
applications. Diffusers shall include integral variable air
pattern controllers for adjustment of airflow spread pattern.
Air pattern controllers shall be adjustable, reversible,
and removable. Diffusers shall include an air volume
measurement outlet to facilitate balancing. K-factor shall
be marked on diffuser. Diffusers shall include an internal
perforated baffle to equalize airflow across the face. Internal
perforated baffle shall be round perforated galvanized metal
with 51% free area.
DVIR diffusers shall have a perforated face plate with round
perforations. Diffuser face plate shall be removable for easy
access to internal air pattern controllers.

Diffuser face plate, side plates, back panel, top panel,


bottom panel, and air pattern controllers plate shall be
constructed of galvannealed material. Internal perforated
baffle shall be constructed of G-90 22 gauge galvanized
metal material.
The finish shall be #26 white powdercoat paint with a baked
on finish. Paint thickness shall be 2.5 3.5 mils. Paint must
pass the ASTM D 3363 pencil hardness test with a minimum
pencil hardness of H 2H. The paint must pass a 1000
hour ASTM B117-97 Corrosive Environments Salt Spray test
without creepage, blistering, or deterioration of film. The
paint must pass the adhesion cross hatch test ASTM D 3359.
Optional accessories shall include duct cover.
The manufacturer shall provide published performance data
for DVIR displacement diffusers. Diffusers shall be tested in
accordance with European standard Nordtest method.

MODEL NUMBER SPECIFICATION

Model
DVIR
XXXX

27
23
16
14
12
8
XX
Unit Size
Dimension 1

www.titus-hvac.com | www.titus-energysolutions.com

Available Model:
DVIR

24 x 3 inlet
20 x 3 inlet
14 x 2 inlet
12 x 2 inlet

Unit Size

Finish

DC
O

XXXXX

XX

XX

12 x 10

26
X

10 x 2 inlet
6 x 2 inlet

12 x 12
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

10
12
16
24
20
12
18
24
30
36
48
24
12
24
12
24

60 x 24

None

Accessories

Special

SPECIFICATIONS

16
16
16
16
20
24
24
24
24
24
24
30
36
36
48
48

White

Duct Cover

T31

Displacement Ventilation

DVRI
Available Model:
DVRI

Includes air volume measurement


outlet to facilitate balancing.
K-factor is marked on outlet.

Rectangular displacement
diffuser that can be positioned
against the wall in a flush or
surface mount orientation.

Material is galvanized
steel and aluminum.
Standard finish is #26
white (powdercoat).

Supplys a large volume of air at


low velocity to the occupied zone.

Optional duct cover and mounting


base available as accessories.

Includes integral variable air


pattern controllers for easy
adjustment of the airflow spread
pattern.

1 1/8"

E
F

D
G

A < 48" SINGLE FRONT COVER

DVRI

A 48 DOUBLE FRONT COVER

T32

All dimensions are in inches.

DVRI

www.titus-hvac.com | www.titus-energysolutions.com

Rectangular Displacement (continued)

Displacement Ventilation

Rectangular Displacement (continued)

Model Inlet Size

DVRI

8
8
8
10
10
10
10
12
12
16
16
24 x 8
32 x 10

Nominal
Unit Size
24
24
24
24
36
48
48
47
60
47
60
47
47

x
x
x
x
x
x
x
x
x
x
x
x
x

24
47
48
79
48
24
36
79
24
79
36
79
79

A
23 1/4
24
24
23 1/4
36
48
48
46 7/8
60
46 7/8
60
46 7/8
46 7/8

B
46 7/8
24
48
78 3/8
48
24
36
78 3/8
24
78 3/8
36
78 3/8
78 3/8

C
11 13/16
11 13/16
11 13/16
13 3/4
13 3/4
13 3/4
13 3/4
16 5/16
16 5/16
19 11/16
19 11/16
11 13/16
13 3/4

Dimensions (inches)
D
E
7 7/8
N/A
7 7/8
N/A
7 7/8
N/A
9 7/8
N/A
9 7/8
N/A
9 7/8
N/A
9 7/8
N/A
11 7/8
N/A
11 7/8
N/A
15 7/8
N/A
15 7/8
N/A
N/A
23 7/8
N/A
31 7/8

F
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7 7/8
9 7/8

G
4 1/2
4 1/2
4 1/2
5 1/2
5 1/2
5 3/4
5 3/4
6 3/4
7 1/16
8 7/16
8 11/16
N/A
N/A

3
3
3
3
3
3
3
3
3
3
3

H
1
/4
1
/4
1
/4
1
/4
1
/4
1
/4
1
/4
1
/4
1
/4
1
/4
1
/4
2
2

www.titus-hvac.com | www.titus-energysolutions.com

DVRI UNIT DIMENSIONS

DVRI
T33

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

ACCESSORIES

Optional telescopic duct cover

T
View with face removed showing integral
variable air pattern controllers

Optional mounting base


Height (J): 2-3/4 or 4
Diffuser height with

Model

cover
*DoesSize
not Includeduct
Mounting
Basekit*
Height.
Unit
Min

24 x 24

ACCESSORIES

24 x 47

T34

DVRI

Height (J): 2-3/4" or 4"

Max

92
70

/2

24 x 48

92

24 x 79

109 7/8

36 x 48

For detailed instructions on how to change the adjacent zone


Optional
Mountingrefer
Base to page T77.
using the variable air pattern
controllers,

92

48 x 24

70

48 x 36

82

47 x 79

109 7/8

60 x 24

70

60 x 36

82

/2

124

/8

/8
/2

*Height dimensions do not


include mounting base.
All dimensions are in inches.

Displacement Ventilation

PERFORMANCE DATA

Unit Size
(W x H)

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

68
0.008
4-4
4-4
68
0.004
4-4
4-4
106
0.003
5-6
5-6
106
0.004
5-4
6-5
154
0.003
7-5
8-5
261
0.004
9-8
10-8

101
0.017
5-6
5-6
101
0.008
5-6
5-6
160
0.008
6-9
6-9
160
0.008
6-6
7-7
231
0.007
8-7
9-8
392
0.009
10-12
12-12

135
0.030
5-8
6-8
135
0.014
5-8
6-8
213
0.014
6-12
7-12
213
0.014
7-8
8-9
308
0.013
9-9
10-10
522
0.015
12-15
13-16

169
0.047
6-9
7-9
169
0.023
6-9
7-9
266
0.022
7-14
8-15
266
0.022
8-10
9-10
385
0.020
10-12
12-12
653
0.024
13-19
14-19

203
0.068
6-11
7-11
203
0.033
6-11
7-11
319
0.032
8-17
9-17
319
0.032
9-12
10-12
461
0.029
11-14
12-14
783
0.034
14-22
16-23

237
0.093
11
7-12
8-13
237
0.044
7-12
8-13
372
0.043
8-19
9-20
372
0.044
9-14
10-14
538
0.039
12-16
13-16
914
0.047
15-25
17-26

271
0.122
16
7-14
8-15
271
0.058
7-14
8-15
425
0.056
9-22
10-22
425
0.057
10-16
11-16
615
0.051
13-18
14-18
1045
0.061
14
16-29
18-29

10 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

106
0.006
6-4
7-4

160
0.013
7-5
8-5

213
0.023
8-7
9-7

266
0.036
9-8
10-8

319
0.052
10-10
11-10

372
0.071
11
10-11
11-11

425
0.092
15
11-12
12-13

10 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

106
0.004
6-4
7-4

160
0.009
7-5
8-5

213
0.015
8-7
9-7

266
0.024
9-8
10-8

319
0.034
10-10
11-10

372
0.047
10-11
11-11

425
0.061
11-12
12-13

24 x 24

8 Dia.

24 x 48

8 Dia.

24 x 79

10 Dia.

36 x 48

10 Dia.

47 x 79

12 Dia.

47 x 79

24 x 8

48 x 24

48 x 36

PERFORMANCE DATA

Neck Velocity

Inlet Size

www.titus-hvac.com | www.titus-energysolutions.com

DVRI

T35

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DVRI (continued)
Unit Size
(W x H)

Inlet Size

60 x 24

12 Dia.

60 x 36

16 Dia.

PERFORMANCE DATA

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

154
0.007
7-4
8-4
275
0.007
10-7
11-7

231
0.016
9-6
10-6
412
0.016
11-10
13-11

308
0.028
10-8
11-8
550
0.029
13-13
15-14

385
0.044
11-10
12-10
687
0.045
14-16
16-17

461
0.064
11
12-11
13-12
825
0.066
15
15-19
17-20

538
0.087
16
13-13
14-13
962
0.089
20
16-22
18-23

615
0.113
20
14-15
15-15
1100
0.117
24
17-25
20-26

PERFORMANCE NOTES:
The adjacent zone (AZ) is the discharge isovel at 1
above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
DT is the under temperature which is the difference
between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.

T36

Neck Velocity

DVRI

Throw values shown are distances in feet for


temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

Displacement Ventilation

SUGGESTED SPECIFICATIONS

Rectangular displacement diffusers shall be Titus model


DVRI of the sizes and mounting types shown on the plans
and outlet schedule. DVRI diffusers shall provide a 1-way
air discharge pattern from the face of diffuser for flush
mount or surface mount applications. Diffusers shall include
integral variable air pattern controllers for adjustment
of airflow spread pattern. Air pattern controllers shall be
adjustable, reversible, and removable. Diffusers shall include
an air volume measurement outlet to facilitate balancing.
K-factor shall be marked on diffuser. Diffusers shall include
an internal perforated baffle to equalize airflow across the
face. Internal perforated baffle shall be round perforated
galvanized metal with 58% free area.
DVRI diffusers shall have a perforated face plate with round
perforations. Diffuser face plate shall be removable for easy
access to internal air pattern controllers.

Diffuser face plate, side plates, back panel, top panel,


bottom panel, and air pattern controllers plate shall be
constructed of galvannealed material. Internal perforated
baffle shall be constructed of G-90 22 gauge galvanized
metal material.
The finish shall be #26 white powdercoat paint with a baked
on finish. Paint thickness shall be 2.5 3.5 mils. Paint must
pass the ASTM D 3363 pencil hardness test with a minimum
pencil hardness of H 2H. The paint must pass a 1000
hour ASTM B117-97 Corrosive Environments Salt Spray test
without creepage, blistering, or deterioration of film. The
paint must pass the adhesion cross hatch test ASTM D 3359.
Optional mounting base shall be offered as an accessory.
The manufacturer shall provide published performance data
for DVRI displacement diffusers. Diffusers shall be tested in
accordance with European standard Nordtest method.

www.titus-hvac.com | www.titus-energysolutions.com

Available Model:
DVRI

MODEL NUMBER SPECIFICATION

Model
DVRI
XXXX

42
32
16
12
10
8
XX
Inlet Size

32 x 10 inlet
24 x 8 inlet
16 inlet

Unit Size

Finish

MB2
MB1
O

XXXXX

XX

XXX

24 x 24

26
X

12 inlet
10 inlet
8 inlet

24 x 47
24
24
36
48
48
47
60
60

x
x
x
x
x
x
x
x

White

Mounting Base 4
Mounting Base 2 3/4
None

Accessories

Special

48
79
48
24
36
79
24
36

SPECIFICATIONS
T37

Displacement Ventilation

DVR3
Available Model:
DVR3

Includes air volume measurement


outlet to facilitate balancing.
K-factor is marked on outlet.

Rectangular displacement
diffuser with 3-way air
discharge pattern for wall or
surface mount applications.

Material is galvanized
steel and aluminum.

Supplys a large volume of air at


low velocity to the occupied zone.

Standard finish is #26


white (powdercoat).

Includes integral variable air


pattern controllers for easy
adjustment of the airflow spread
pattern.

Optional duct cover and mounting


base available as accessories.

D
G
C
A < 48" SINGLE FRONT COVER

A
H

DVR3

A 48 DOUBLE FRONT COVER

T38

All dimensions are in inches.

DVR3

www.titus-hvac.com | www.titus-energysolutions.com

Rectangular Displacement (continued)

Displacement Ventilation

Rectangular Displacement (continued)

Model Inlet Size

DVR3

Nominal
Unit Size

8
10
10
12
12
10
12
10
12
16 x 6

24 x 24
24 x 48
24 x 60
36 x 48
36 x 60
48 x 24
48 x 36
60 x 24
60 x 24
24 x 24

A
24
24
24
36
36
48
48
60
60
24

16 x 8
18 x 8
16 x 8

24 x 24
24 x 24
24 x 24

24
24
48

B
24
48
60
48
60
24
36
24
36
24

C
12
13 3/4
13 3/4
16 1/4
16 1/4
13 3/4
16 1/4
13 3/4
16 1/4
12

48
60
24

13 3/4
13 3/4
13 3/4

Unit Dimensions (inches)


D
E
7 7/8
N/A
9 7/8
N/A
9 7/8
N/A
11 7/8
N/A
11 7/8
N/A
9 7/8
N/A
11 7/8
N/A
9 7/8
N/A
11 7/8
N/A
N/A
15 7/8
N/A
N/A
N/A

15 7/8
17 7/8
15 7/8

F
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5 7/8

G
4 1/2
5 3/8
5 3/8
6 5/8
6 5/8
5 3/8
6 5/8
5 3/8
6 5/8
4 3/8

H
3 1/4
3 1/4
3 1/4
3 1/4
3 1/4
3 1/4
3 1/4
3 1/4
3 1/4
2

7 7/8
7 7/8
7 7/8

5 3/8
4 7/8
5 3/8

2
2
2

www.titus-hvac.com | www.titus-energysolutions.com

DVR3 UNIT DIMENSIONS

DVR3
T39

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

ACCESSORIES

Optional telescopic duct cover

T
View with face removed showing integral
variable air pattern controllers

ACCESSORIES

Optional mounting base


Height (J): 2-3/4 or 4

T40

Unit Size

Diffuser height with duct cover kit*


Min

24 x 24

70 1/2

24 x 48

92

24 x 60

92

36 x 48

92

36 x 60

92

48 x 24

70 1/2

48 x 36

82 1/2

60 x 24

70 1/2

60 x 36

82 1/2

For detailed instructions on how to change the adjacent zone


using the variable air pattern controllers, refer to page T77.

Max

124

All dimensions are in inches.

Displacement Ventilation

PERFORMANCE DATA

Unit Size
(W x H)

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

68
0.005
2-6
2-6
106
0.004
3-8
3-8
106
0.003
3-8
3-8
106
0.005
2-7
3-7
106
0.004
2-6
2-7
154
0.004
3-9
4-10

101
0.011
3-7
3-8
160
0.008
4-10
5-11
160
0.007
4-10
5-11
160
0.010
3-9
4-10
160
0.009
3-8
3-9
231
0.008
5-12
5-13

135
0.020
4-9
4-10
213
0.015
6-13
6-14
213
0.013
6-13
6-14
213
0.018
4-11
5-12
213
0.016
4-10
4-11
308
0.014
6-15
7-16

169
0.032
5-11
5-12
266
0.023
7-15
7-16
266
0.020
7-15
7-16
266
0.028
5-13
6-14
266
0.025
5-12
5-13
385
0.023
7-17
8-19

203
0.046
6-12
6-14
319
0.033
8-17
8-19
319
0.028
8-17
8-19
319
0.041
6-15
6-16
319
0.036
5-14
6-15
461
0.032
9-20
9-22

237
0.063
6-14
7-15
372
0.045
9-19
9-21
372
0.039
9-19
9-21
372
0.056
7-16
7-18
372
0.049
6-16
7-17
538
0.044
10-22
11-25

271
0.082
11
7-15
8-17
425
0.059
10-21
11-23
425
0.050
10-21
11-23
425
0.073
11
8-18
8-20
425
0.064
10
7-17
7-19
615
0.058
10
11-25
12-27

12 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

154
0.003
3-9
4-10

231
0.007
5-12
5-13

308
0.012
6-15
7-16

385
0.019
7-17
8-19

461
0.028
9-20
9-22

538
0.038
10-22
11-25

615
0.049
11-25
12-27

12 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

154
0.004
3-8
3-9

231
0.008
4-11
5-13

308
0.015
6-14
6-15

385
0.023
7-17
7-18

461
0.033
8-19
8-21

538
0.045
9-21
10-23

615
0.059
10
10-23
11-26

12 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

154
0.006
3-8
3-9

231
0.013
4-11
4-12

308
0.024
5-13
5-15

385
0.037
6-16
7-17

461
0.053
7-18
8-20

538
0.073
12
8-20
9-22

615
0.095
16
9-22
10-24

24 x 24

8 Dia.

24 x 48

10 Dia.

24 x 60

10 Dia.

48 x 24

10 Dia.

60 x 24

10 Dia.

36 x 48

12 Dia.

36 x 60

48 x 36

60 x 36

PERFORMANCE DATA

Neck Velocity

Inlet Size

www.titus-hvac.com | www.titus-energysolutions.com

DVR3

T41

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DVR3 (continued)
Unit Size
(W x H)

Inlet Size

24 x 24

16 x 6

24 x 48

16 x 8

24 x 60

18 x 8

48 x 24

16 x 8

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

130
0.013
4-9
4-10
174
0.006
5-11
5-12
196
0.005
5-12
5-13
174
0.008
4-9
4-10

194
0.029
5-12
6-13
260
0.014
7-15
7-16
293
0.012
7-16
8-18
260
0.019
5-13
5-14

259
0.051
7-15
7-16
347
0.025
8-18
9-20
391
0.021
9-20
10-22
347
0.034
6-16
7-17

324
0.080
8-18
9-19
434
0.038
10-21
11-23
489
0.033
11-23
12-26
434
0.052
8-18
8-20

389
0.115
13
10-20
10-22
521
0.055
12-24
13-27
587
0.048
13-26
14-29
521
0.076
11
9-21
10-23

453
0.156
18
11-23
12-25
608
0.075
13
13-27
14-30
684
0.065
12
15-30
16-33
608
0.103
16
10-24
11-26

518
0.204
22
12-25
13-27
695
0.098
17
15-30
16-33
782
0.085
16
17-33
18-36
695
0.135
20
12-26
12-29

PERFORMANCE NOTES:

PERFORMANCE DATA

The adjacent zone (AZ) is the discharge isovel at 1


above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
DT is the under temperature which is the difference
between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.

DVR3

T42

Throw values shown are distances in feet for


temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

Displacement Ventilation

SUGGESTED SPECIFICATIONS

Rectangular displacement diffusers shall be Titus model


DVR3 of the sizes and mounting types shown on the plans
and outlet schedule. DVR3 diffusers shall provide a 1-way
air discharge pattern from the face of diffuser for flush
mount or surface mount applications. Diffusers shall include
integral variable air pattern controllers for adjustment
of airflow spread pattern. Air pattern controllers shall be
adjustable, reversible, and removable. Diffusers shall include
an air volume measurement outlet to facilitate balancing.
K-factor shall be marked on diffuser. Diffusers shall include
an internal perforated baffle to equalize airflow across the
face. Internal perforated baffle shall be round perforated
galvanized metal with 58% free area.
DVR3 diffusers shall have a perforated face plate with round
perforations. Diffuser face plate shall be removable for easy
access to internal air pattern controllers.

Diffuser face plate, side plates, back panel, top panel,


bottom panel, and air pattern controllers plate shall be
constructed of galvannealed material. Internal perforated
baffle shall be constructed of G-90 22 gauge galvanized
metal material.
The finish shall be #26 white powdercoat paint with a baked
on finish. Paint thickness shall be 2.5 3.5 mils. Paint must
pass the ASTM D 3363 pencil hardness test with a minimum
pencil hardness of H 2H. The paint must pass a 1000
hour ASTM B117-97 Corrosive Environments Salt Spray test
without creepage, blistering, or deterioration of film. The
paint must pass the adhesion cross hatch test ASTM D 3359.
Optional mounting base shall be offered as an accessory.
The manufacturer shall provide published performance data
for DVR3 displacement diffusers. Diffusers shall be tested in
accordance with European standard Nordtest method.

MODEL NUMBER SPECIFICATION

Model
DVR3
XXXX

26
24
22
12
10
8
XX
Inlet Size

www.titus-hvac.com | www.titus-energysolutions.com

Available Model:
DVR3

18 x 8 inlet
16 x 8 inlet
16 x 6 inlet

Unit Size

Finish

MB2
MB1
O

XXXXX

XX

XXX

24 x 24

26
X

12 inlet
10 inlet
8 inlet

24 x 48
24
36
36
48
48
60
60

x
x
x
x
x
x
x

White

Mounting Base 4
Mounting Base 2 3/4
None

Accessories

Special

60
48
60
24
36
24
36

SPECIFICATIONS
T43

Includes air volume


measurement
outlet to facilitate
balancing. K-factor is
marked on outlet.

Available Model:
DV180
Semi-circular displacement diffuser
with 180B air discharge pattern for wall
or surface mount applications.

DV180

www.titus-hvac.com | www.titus-energysolutions.com

Displacement Ventilation

Semi-Circular Displacement
DV180

Material is galvanized
steel and aluminum.

Designed to supply a large volume of air


at low velocity to the occupied zone.

Standard finish is #26


white (powdercoat).

Includes integral variable air pattern controllers for


easy adjustment of the airflow spread pattern.

Mounting base and telescopic duct cover


are available as accessories.
A
G

D
H

DV180

T44

Model

Inlet
Size

DV180

6
8
8
10
10
10
12
12

Nominal
Unit Size
18
24
24
24
30
30
30
30

x
x
x
x
x
x
x
x

24
24
36
48
24
36
48
60

A
18
24
24
24
30
30
30
30

B
24
24
36
48
24
36
48
60

Dimensions
C
10 1/8
13 1/8
13 1/8
13 1/8
16 1/8
16 1/8
16 1/8
16 1/8

All dimensions are in inches.

(inches)
D
5 7/8
7 7/8
7 7/8
9 7/8
9 7/8
9 7/8
11 7/8
11 7/8

4
5
5
6
6
7
7
7

G
5
/8
7
/8
7
/8
1
/6
1
/6
1
/8
1
/8
5
/8

3
3
3
3
3
3
3
3

H
1
/4
1
/4
1
/4
1
/4
1
/4
1
/4
1
/4
1
/4

Displacement Ventilation

ACCESSORIES

www.titus-hvac.com | www.titus-energysolutions.com

Optional telescopic duct cover

Unit Size

Diffuser height with duct cover kit*


Min

18x24

92

24x24

92

24x36

84

24x48

92

30x24

72

30x36

77 5/8

30x48

92

30x60

92

Max

124

118 7/16
124

View with face removed showing integral


variable air pattern controllers

Optional mounting base


Height (J): 2-3/4 or 4

All dimensions are in inches.

ACCESSORIES

For detailed instructions on how to change the adjacent zone


using the variable air pattern controllers, refer to page T77.

T45

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DV180
Unit Size
(W x H)

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

38
0.003
2-4
2-4
68
0.004
3-6
3-6
68
0.003
3-6
3-6
106
0.003
4-8
4-8
106
0.004
4-8
4-8
160
0.007
5-10
6-12

56
0.007
3-6
3-6
101
0.008
4-8
4-8
101
0.007
4-8
4-8
160
0.007
5-10
6-12
160
0.009
5-10
6-12
213
0.013
6-12
7-14

75
0.013
3-6
4-8
135
0.014
4-8
5-10
135
0.013
4-8
5-10
213
0.013
6-12
7-14
213
0.016
6-12
7-14
266
0.021
7-14
8-16

94
0.020
4-8
4-8
169
0.022
5-10
6-12
169
0.020
5-10
6-12
266
0.020
7-14
8-16
266
0.024
7-14
8-16
319
0.030
8-16
9-18

113
0.029
4-8
5-10
203
0.032
6-12
7-14
203
0.028
6-12
7-14
319
0.029
8-16
9-18
319
0.035
8-16
9-18
425
0.053
13
9-18
10-20

132
0.040
4-8
5-10
237
0.043
6-12
7-14
237
0.039
6-12
7-14
372
0.040
8-16
10-20
372
0.048
8-16
9-18
532
0.082
21
10-20
12-24

151
0.052
5-10
6-12
271
0.057
10
7-14
8-16
271
0.050
7-14
8-16
425
0.052
12
9-18
10-20
425
0.062
14
9-18
10-20
638
0.119
27
12-24
13-26

12 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

154
0.003
5-10
5-10

231
0.008
6-12
7-14

308
0.013
7-14
8-16

385
0.021
8-16
10-20

461
0.030
10-20
11-22

538
0.041
11
10-20
12-24

615
0.053
15
11-22
13-26

12 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

154
0.003
5-10
5-10

231
0.007
6-12
7-14

308
0.013
7-14
8-16

385
0.020
8-16
10-20

461
0.029
10-20
11-22

538
0.039
10
10-20
12-24

615
0.051
15
11-22
13-26

6 Dia.

24 x 24

8 Dia.

24 x 36

8 Dia.

24 x 48

10 Dia.

30 x 24

10 Dia.

30 x 36

10 Dia.

30 x 60

PERFORMANCE DATA

200

18 x 24

30 x 48

T46

Neck Velocity

Inlet Size

Displacement Ventilation

PERFORMANCE DATA

The adjacent zone (AZ) is the discharge isovel at 1


above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
DT is the under temperature which is the difference
between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.

Throw values shown are distances in feet for


temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE NOTES:

DV180

PERFORMANCE DATA
T47

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS
Available Model:
DV180
Semi-circular displacement diffusers shall be Titus model
DV180 of the sizes and mounting types shown on the plans
and outlet schedule. DV180 diffusers shall provide a 180
degree air discharge pattern from the face and sides of
diffuser for wall or surface mount applications. Diffusers
shall include integral variable air pattern controllers for
adjustment of airflow spread pattern. Air pattern controllers
shall be adjustable, reversible, and removable. Diffusers
shall include an air volume measurement outlet to facilitate
balancing. K-factor shall be marked on diffuser. Diffusers
shall include an internal perforated baffle to equalize airflow
across the face. Internal perforated baffle shall be round
perforated galvanized metal with 51% free area.
DV180 diffusers shall have a perforated face plate with
round perforations. Diffuser face plate shall be removable
for easy access to internal air pattern controllers.

bottom panel, and air pattern controllers plate shall be


constructed of galvannealed material. Internal perforated
baffle shall be constructed of G-90 22 gauge galvanized
metal material.
The finish shall be #26 white powdercoat paint with a
baked on finish. Paint thickness shall be 2.5 3.5 mils.
Paint must pass the ASTM D 3363 pencil hardness test with
a minimum pencil hardness of H 2H. The paint must pass
a 1000 hour ASTM B117-97 Corrosive Environments Salt
Spray test without creepage, blistering, or deterioration
of film. The paint must pass the adhesion cross hatch test
ASTM D 3359.
Optional accessories shall include telescopic duct cover and
mounting base.
The manufacturer shall provide published performance data
for DV180 displacement diffusers. Diffusers shall be tested
in accordance with European standard Nordtest method.

Diffuser face plate, side plates, back panel, top panel,

MODEL NUMBER SPECIFICATION

Model
DV180
XXXXX

12
10
8
6
XX
Inlet Size
Dimension 1

Unit Size

Finish

MB2
MB1
DC
O

XXXXX

XX

XXX

18 x 24

26
X

12 inlet
10 inlet
8 inlet
6 inlet

24 x 24

SPECIFICATIONS

24
24
30
30
30
30

T48

x
x
x
x
x
x

36
48
24
36
48
60

White
Special

Accessories

Mounting Base 4
Mounting Base 2 3/4
Duct Cover
None

Displacement Ventilation

Semi-Circular Displacement (continued)

Semi-circular displacement diffuser


with 180B air discharge pattern for wall
or surface mount applications.

Material is galvanized
steel and aluminum.

Designed to supply a large volume of air


at low velocity to the occupied zone.

Includes integral variable air pattern controllers for


easy adjustment of the airflow spread pattern.

Standard finish is #26


white (powdercoat).
Mounting base and telescopic duct cover
are available as accessories.

DVHC

Includes air volume


measurement outlet to
facilitate balancing. K-factor
is marked on outlet.

Available Model:
DVHC

www.titus-hvac.com | www.titus-energysolutions.com

DVHC

G
C

/4"
D

3 1/4"

B
B

DVHC

All dimensions are in inches.

T49

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

Semi-Circular Displacement (continued)

DVHC

T50

DVHC UNIT DIMENSIONS


Model

DVHC

Inlet
Size

Nominal
Unit Size

5
6
8
10
12
16
12
14
16
20

10
11
13
15
18
21
24
24
24
25

x
x
x
x
x
x
x
x
x
x

25
25
37
37
60
79
24
36
48
79

A
9 5/8
11
12 9/16
14 1/2
17
20 3/8
24
24
24
24 3/8

24
14
16
20
32

30
36
36
36
37

x
x
x
x
x

79
24
36
48
79

29 1/2
36
36
36
36 1/4

Dimensions (inches)
B
C
D
24 1/2
9 9/16
4 7/8
24 1/2
11
5 7/8
36 5/16
12 1/2
7 7/8
36 5/16
14 1/2
9 7/8
60
17
11 7/8
78 7/8
20 5/16
15 7/8
24
24
19 7/8
36
24
19 7/8
48
24
19 7/8
78 7/8
24 3/8
19 7/8

G
4 13/16
5 1/2
6 5/16
7 5/16
8 9/16
10 1/4
11 15/16
11 15/16
11 15/16
12 3/16

78 7/8
24
36
48
78 7/8

14 3/4
18 1/16
18 1/16
18 1/16
18 1/8

29 1/2
36
36
36
36 3/16

23
31
31
31
31

/8
/8
7
/8
7
/8
7
/8
7
7

Displacement Ventilation

ACCESSORIES

www.titus-hvac.com | www.titus-energysolutions.com

Optional telescopic duct cover

DVHC
Unit Size

Diffuser height with


duct cover
Min
Max

10 x 26

92 1/8

11 x 26

92 1/8

13 x 37

84 3/8

15 x 37

84 3/8

18 x 60

92 1/8

21 x 79

109 7/8

24 x 24

72

24 x 36

84

24 x 48

92 5/16

25 x 79

109 7/8

30 x 79

109 7/8

36 x 24

72

36 x 36

84

36 x 48

92 5/16

37 x 79

109 7/8

124

T
View with face removed showing integral
variable air pattern controllers

Optional mounting base


Height (J): 2-3/4 or 4

All dimensions are in inches.

ACCESSORIES

For detailed instructions on how to change the adjacent zone


using the variable air pattern controllers, refer to page T77.

T51

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DVHC
Unit Size
(W x H)

11 x 25

6 Dia.

13 x 37

8 Dia.

15 x 37

10 Dia.

18 x 60

12 Dia.

24 x 24

12 Dia.

24 x 36

14 Dia.

PERFORMANCE DATA

24 x 48

T52

Inlet Size

16 Dia.

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

38
0.004
3-8
4-9
68
0.004
4-11
5-13
106
0.004
5-14
7-17
154
0.004
7-18
8-21
154
0.004
8-18
10-21
210
0.004
9-22
11-25

56
0.008
3-10
4-11
101
0.008
5-14
6-16
160
0.009
6-18
8-21
231
0.008
8-23
10-27
231
0.009
9-23
12-27
315
0.009
11-28
13-33

75
0.015
4-12
5-13
135
0.015
5-17
7-19
213
0.015
7-22
9-26
308
0.015
9-27
11-32
308
0.016
10-27
13-32
420
0.015
12-33
15-39

94
0.023
4-13
5-15
169
0.023
6-19
7-22
266
0.024
8-25
9-29
385
0.023
10-31
12-37
385
0.025
11-31
14-37
525
0.024
13-38
16-44

113
0.033
5-15
6-17
203
0.033
6-21
8-25
319
0.035
8-28
10-33
461
0.033
10-35
13-41
461
0.036
10
12-35
15-41
630
0.035
11
14-42
17-50

132
0.045
5-16
6-19
237
0.045
10
7-23
8-27
372
0.047
13
9-31
11-36
538
0.045
13
11-38
14-45
538
0.049
15
13-39
16-45
735
0.047
16
15-47
18-54

151
0.059
11
5-18
6-21
271
0.059
14
7-25
9-29
425
0.062
17
9-33
11-39
615
0.058
17
11-42
14-49
615
0.064
19
14-42
17-49
840
0.062
20
16-50
19-59

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

275
0.004
10-26
13-30

412
0.009
12-33
15-38

550
0.015
13-39
16-46

687
0.024
14-45
18-52

825
0.035
12
15-50
19-58

962
0.047
17
16-55
21-64

1100
0.061
21
17-59
22-70

Displacement Ventilation

PERFORMANCE DATA

Unit Size
(W x H)

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

210
0.004
11-22
14-26
275
0.004
13-26
16-30

315
0.009
13-28
17-33
412
0.008
15-33
19-38

420
0.015
15-33
19-39
550
0.015
17-39
21-46

525
0.024
16-38
20-45
687
0.023
18-45
23-53

630
0.035
11
17-43
22-50
825
0.034
11
19-50
24-59

735
0.047
16
19-47
23-55
962
0.046
16
21-55
26-64

840
0.061
20
20-51
25-59
1100
0.060
20
22-60
27-70

Inlet Size

36 x 24

14 Dia.

36 x 36

16 Dia.

PERFORMANCE NOTES:
The adjacent zone (AZ) is the discharge isovel at 1
above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
DT is the under temperature which is the difference
between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.

Throw values shown are distances in feet for


temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

www.titus-hvac.com | www.titus-energysolutions.com

DVHC (continued)

DVHC

PERFORMANCE DATA

T53

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS
Available Model:
DVHC
Semi-circular displacement diffusers shall be Titus model
DVHC of the sizes and mounting types shown on the plans
and outlet schedule. DVHC diffusers shall provide a 180
degree air discharge pattern from the face and sides of
diffuser for wall or surface mount applications. Diffusers
shall include integral variable air pattern controllers for
adjustment of airflow spread pattern. Air pattern controllers
shall be adjustable, reversible, and removable. Diffusers
shall include an air volume measurement outlet to facilitate
balancing. K-factor shall be marked on diffuser. Diffusers
shall include an internal perforated baffle to equalize airflow
across the face. Internal perforated baffle shall be round
perforated galvanized metal with 51% free area.
DVHC diffusers shall have a perforated face plate with
round perforations. Diffuser face plate shall be removable
for easy access to internal air pattern controllers.

bottom panel, and air pattern controllers plate shall be


constructed of galvannealed material. Internal perforated
baffle shall be constructed of G-90 22 gauge galvanized
metal material.
The finish shall be #26 white powdercoat paint with a
baked on finish. Paint thickness shall be 2.5 3.5 mils.
Paint must pass the ASTM D 3363 pencil hardness test with
a minimum pencil hardness of H 2H. The paint must pass
a 1000 hour ASTM B117-97 Corrosive Environments Salt
Spray test without creepage, blistering, or deterioration
of film. The paint must pass the adhesion cross hatch test
ASTM D 3359.
Optional accessories shall include telescopic duct cover and
mounting base.
The manufacturer shall provide published performance data
for DVHC displacement diffusers. Diffusers shall be tested
in accordance with European standard Nordtest method.

Diffuser face plate, side plates, back panel, top panel,

MODEL NUMBER SPECIFICATION

Model
DVHC
XXXX

32
24
20
16
14
12
10
8
6
5
XX
Inlet Size

32 inlet
24 inlet
20 inlet
16 inlet
14 inlet
12 inlet

Unit Size

Finish

MB2
MB1
DC
O

XXXXX

XX

XXX

10 x 25

26
X

10 inlet
8 inlet
6 inlet
5 inlet

SPECIFICATIONS

11 x 25

T54

13
15
18
21
24
24
24
25
30
36
36
36
37

x
x
x
x
x
x
x
x
x
x
x
x
x

37
37
60
79
24
36
48
79
79
24
36
48
79

White
Special

Accessories

Mounting Base 4
Mounting Base 2 3/4
Duct Cover
None

Displacement Ventilation
Material is galvanized
steel and aluminum.

Available Model:
DVC1

Designed to supply a large volume of air


at low velocity to the occupied zone.
Includes integral variable air pattern controllers for easy
adjustment of the airflow spread pattern.

Standard finish is #26


white (powdercoat).
Mounting base and
telescopic duct
cover are available
as accessories.

Includes air volume measurement outlet to


facilitate balancing. K-factor is marked on outlet.

DVC1

Flat face displacement diffuser with 90B air


discharge pattern for corner mount applications.

www.titus-hvac.com | www.titus-energysolutions.com

Corner Mount Displacement


DVC1

C
A

D
3 1/4"

DVC1

All dimensions are in inches.

T55

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

Corner Mount Displacement (continued)

DVC1

T56

DVC1 UNIT DIMENSIONS


Model

DVC1

Inlet
Size

Nominal
Unit Size

8
8
8
8
8
8
8
8
10
10

24
24
24
24
24
30
30
30
30
30

x
x
x
x
x
x
x
x
x
x

24
36
48
60
72
24
36
48
60
72

A
24
24
24
24
24
30
30
30
30
30

10
10
10
12
12

36
36
36
36
36

x
x
x
x
x

24
36
48
60
72

36
36
36
36
36

Unit Dimensions (inches)


B
C
D
24
17
7 7/8
36
17
7 7/8
48
17
7 7/8
60
17
7 7/8
72
17
7 7/8
24
20 5/8
7 7/8
36
20 5/8
7 7/8
48
20 5/8
7 7/8
60
20 5/8
9 7/8
72
20 5/8
9 7/8

6
6
6
6
6
8
8
8
8
8

24
36
48
60
72

10
10
10
10
10

25
25
25
25
25

/2
/2
1
/2
1
/2
1
/2
1
1

9 7/8
9 7/8
9 7/8
11 7/8
11 7/8

G
1
/2
1
/2
1
/2
1
/2
1
/2
1
/4
1
/4
1
/4
1
/4
1
/4
/2
/2
1
/2
1
/2
1
/2
1
1

Displacement Ventilation

ACCESSORIES

www.titus-hvac.com | www.titus-energysolutions.com

Optional telescopic duct cover

Unit Size

Diffuser height with


duct cover kit*
Min
Max

24 x 24
24 x 36
24 x 48
24 x 60
24 x 72
30 x 24
30 x 36
30 x 48

92

124

30 x 60
30 x 72
36 x 24

36 x 36
36 x 48
36 x 60
36 x 72

*Height dimensions do not


include mounting base.

View with face removed showing integral


variable air pattern controllers

J
Optional mounting base
Height (J): 2-3/4 or 4

For detailed instructions on how to change the adjacent zone


using the variable air pattern controllers, refer to page T77.

ACCESSORIES

All dimensions are in inches.

T57

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DVC1
Unit Size
(W x H)

300

400

500

600

700

800

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

68
0.004
3-4
3-4
68
0.004
3-4
3-4
68
0.003
3-4
3-4
68
0.003
3-4
3-4
68
0.003
3-4
3-4
68
0.004
3-3
3-4

101
0.010
4-5
5-6
101
0.008
4-5
5-6
101
0.007
4-5
5-6
101
0.007
4-5
5-6
101
0.007
4-5
5-6
101
0.009
4-5
4-5

135
0.018
6-7
6-7
135
0.014
6-7
6-7
135
0.013
6-7
6-7
135
0.013
6-7
6-7
135
0.012
6-7
6-7
135
0.016
5-6
5-6

169
0.027
7-8
7-9
169
0.022
7-8
7-9
169
0.020
7-8
7-9
169
0.020
7-8
7-9
169
0.019
7-8
7-9
169
0.025
6-7
6-8

203
0.040
8-10
8-10
203
0.032
8-10
8-10
203
0.029
8-10
8-10
203
0.028
8-10
8-10
203
0.028
8-10
8-10
203
0.036
7-9
7-9

237
0.054
12
9-11
9-12
237
0.043
9-11
9-12
237
0.040
9-11
9-12
237
0.039
9-11
9-12
237
0.038
9-11
9-12
237
0.049
10
8-10
8-10

271
0.070
16
10-12
11-13
271
0.056
12
10-12
11-13
271
0.052
10-12
11-13
271
0.050
10-12
11-13
271
0.049
10-12
11-13
271
0.063
15
9-11
9-11

8 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

68
0.003
3-3
3-4

101
0.008
4-5
4-5

135
0.013
5-6
5-6

169
0.021
6-7
6-8

203
0.030
7-9
7-9

237
0.041
8-10
8-10

271
0.054
10
9-11
9-11

8 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

68
0.003
3-3
3-4

101
0.007
4-5
4-5

135
0.013
5-6
5-6

169
0.020
6-7
6-8

203
0.029
7-9
7-9

237
0.039
8-10
8-10

271
0.051
9-11
9-11

10 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

106
0.003
4-5
4-5

160
0.007
6-7
6-7

213
0.013
7-9
8-9

266
0.020
9-11
9-11

319
0.029
10-12
11-13

372
0.040
11-14
12-15

425
0.052
12
13-16
13-17

8 Dia.

24 x 36

8 Dia.

24 x 48

8 Dia.

24 x 60

8 Dia.

24 x 72

8 Dia.

30 x 24

8 Dia.

30 x 48

PERFORMANCE DATA

200
0.002

24 x 24

30 x 36

T58

Neck Velocity
Velocity Pressure

Inlet Size

30 x 60

Displacement Ventilation

PERFORMANCE DATA

Unit Size
(W x H)

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

106
0.003
4-5
4-5
106
0.004
4-4
4-5
106
0.003
4-4
4-5
106
0.003
4-4
4-5
154
0.003
5-6
5-6
154
0.003
5-6
5-6

160
0.007
6-7
6-7
160
0.010
5-6
5-6
160
0.008
5-6
5-6
160
0.007
5-6
5-6
231
0.007
7-8
7-9
231
0.007
7-8
7-9

213
0.013
7-9
8-9
213
0.017
6-8
7-8
213
0.014
6-8
7-8
213
0.013
6-8
7-8
308
0.013
9-11
9-11
308
0.013
9-11
9-11

266
0.020
9-11
9-11
266
0.027
8-10
8-10
266
0.022
8-10
8-10
266
0.020
8-10
8-10
385
0.021
11-13
11-14
385
0.020
11-13
11-14

319
0.029
10-12
11-13
319
0.039
9-11
9-12
319
0.032
9-11
9-12
319
0.029
9-11
9-12
461
0.030
12-15
13-16
461
0.029
12-15
13-16

372
0.039
11-14
12-15
372
0.053
14
10-13
11-13
372
0.043
10
10-13
11-13
372
0.040
10-13
11-13
538
0.041
10
14-17
15-18
538
0.039
14-17
15-18

425
0.051
10
13-16
13-17
425
0.070
19
11-14
12-15
425
0.056
14
11-14
12-15
425
0.052
11
11-14
12-15
615
0.053
14
16-19
16-20
615
0.051
13
16-19
16-20

Inlet Size

30 x 72

10 Dia.

36 x 24

10 Dia.

36 x 36

10 Dia.

36 x 48

10 Dia.

36 x 60

12 Dia.

36 x 72

12 Dia.

www.titus-hvac.com | www.titus-energysolutions.com

DVC1 (continued)

PERFORMANCE NOTES:
Throw values shown are distances in feet for
temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

PERFORMANCE DATA

The adjacent zone (AZ) is the discharge isovel at 1


above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
DT is the under temperature which is the difference
between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.

L
W

DVC1

T59

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

Available Model:
DVC1
Corner mount displacement diffusers shall be Titus model
DVC1 of the sizes and mounting types shown on the plans
and outlet schedule. DVC1 diffusers shall provide a 90
degree air discharge pattern for corner mount applications.
Diffusers shall include integral variable air pattern controllers
for adjustment of airflow spread pattern. Air pattern
controllers shall be adjustable, reversible, and removable.
Diffusers shall include an air volume measurement outlet
to facilitate balancing. K-factor shall be marked on diffuser.
Diffusers shall include an internal perforated baffle to
equalize airflow across the face. Internal perforated baffle
shall be round perforated galvanized metal with 51% free
area.
DVC1 diffusers shall have a perforated face plate with round
perforations. Diffuser face plate shall be removable for easy
access to internal air pattern controllers.

DVC1
XXXX

12
10
8
XX
Inlet Size

Optional accessories shall include telescopic duct cover and


mounting base.
The manufacturer shall provide published performance data
for DVC1 displacement diffusers. Diffusers shall be tested in
accordance with European standard Nordtest method.

Unit Size

Finish

MB2
MB1
DC
O

XX

XX

XXXX

24 x 24

26
X

12 inlet
10 inlet
8 inlet

24 x 36

SPECIFICATIONS

The finish shall be #26 white powdercoat paint with a baked


on finish. Paint thickness shall be 2.5 3.5 mils. Paint must
pass the ASTM D 3363 pencil hardness test with a minimum
pencil hardness of H 2H. The paint must pass a 1000
hour ASTM B117-97 Corrosive Environments Salt Spray test
without creepage, blistering, or deterioration of film. The
paint must pass the adhesion cross hatch test ASTM D 3359.

MODEL NUMBER SPECIFICATION

Model

T60

Diffuser face plate, side plates, back panel, top panel,


bottom panel, and air pattern controllers plate shall be
constructed of galvannealed material. Internal perforated
baffle shall be constructed of G-90 22 gauge galvanized
metal material.

24
24
24
30
30
30
30
30
36
36
36
36
36

x
x
x
x
x
x
x
x
x
x
x
x
x

48
60
72
24
36
48
60
72
24
36
48
60
72

White
Special

Accessories

Mounting Base 4
Mounting Base 2 3/4
Duct Cover
None

Displacement Ventilation

Corner Mount Displacement (continued)

Material is galvanized
steel and aluminum.

Available Model:
DVVC

Designed to supply a large volume of air


at low velocity to the occupied zone.
Includes integral variable air pattern controllers for easy
adjustment of the airflow spread pattern.

Standard finish is #26


white (powdercoat).
Mounting base and
telescopic duct
cover are available
as accessories.

Includes air volume measurement outlet to


facilitate balancing. K-factor is marked on outlet.

DVVC

Curved face displacement diffuser with 90B air


discharge pattern for corner mount applications.

www.titus-hvac.com | www.titus-energysolutions.com

DVVC

G
A

D
3 1/4"

DVVC

All dimensions are in inches.

T61

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

Corner Mount Displacement (continued)

DVVC

T62

DVVC UNIT DIMENSIONS


Model

Inlet
Size

DVVC

5
6
8
10
12
16
10
12
14
14
16
16

Nominal
Unit Size
10
11
13
15
18
21
24
24
24
30
30
30

x
x
x
x
x
x
x
x
x
x
x
x

25
25
37
37
60
79
24
36
48
24
36
48

A
9 5/8
11
12 5/8
14 5/8
17 1/8
20 1/2
24
24
24
30
30
30

Dimensions
B
24 1/2
24 1/2
36 5/16
36 5/16
60
78 7/8
24
36
48
24
36
48

(inches)
D
4 7/8
5 7/8
7 7/8
9 7/8
11 7/8
15 7/8
19 7/8
19 7/8
19 7/8
23 7/8
23 7/8
23 7/8

G
4 7/8
5 1/2
6 5/16
7 5/16
8 5/8
10 1/4
12
12
12
15
15
15

Displacement Ventilation

ACCESSORIES

www.titus-hvac.com | www.titus-energysolutions.com

Optional telescopic duct cover

Unit Size

Diffuser height with duct cover kit*


Min

10 x 25

92 1/8

11 x 25

92 1/8

13 x 37

84 3/8

15 x 37

84 3/8

18 x 60

92 1/8

21 x 79

109 7/8

24 x 24

92 1/8

24 x 36

84

24 x 48

92 1/8

30 x 24

72

30 x 36

84

30 x 48

92 1/8

Max

124

*Height dimensions do not


include mounting base.

View with face removed showing integral


variable air pattern controllers

Optional mounting base


Height (J): 2-3/4 or 4

All dimensions are in inches.

ACCESSORIES

For detailed instructions on how to change the adjacent zone


using the variable air pattern controllers, refer to page T77.

T63

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DVVC
Unit Size
(W x H)

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

38
0.004
2-3
2-3
106
0.004
5-6
5-6
154
0.004
6-7
6-7
275
0.004
8-10
9-10
106
0.004
3-4
4-4
154
0.004
5-6
5-6

56
0.008
3-4
3-4
160
0.009
7-8
7-8
231
0.008
8-10
8-10
412
0.008
12-14
12-15
160
0.009
5-6
5-6
231
0.009
6-8
7-8

75
0.015
4-5
4-5
213
0.016
8-10
9-11
308
0.014
10-13
11-13
550
0.015
15-18
15-19
213
0.016
6-7
6-8
308
0.015
8-10
9-10

94
0.023
5-6
5-7
266
0.025
10-12
10-13
385
0.022
12-15
13-16
687
0.024
18-22
18-23
266
0.025
7-9
8-9
385
0.024
10-12
10-13

113
0.033
6-7
6-8
319
0.035
12-14
12-15
461
0.032
14-18
15-18
825
0.034
11
20-26
21-27
319
0.037
8-10
9-11
461
0.035
11-14
12-15

132
0.045
7-8
7-9
372
0.048
12
13-16
14-17
538
0.043
12
16-20
17-21
962
0.046
17
23-29
24-30
372
0.050
13
10-12
10-12
538
0.047
14
13-16
14-17

151
0.059
10
7-9
8-10
425
0.063
17
15-18
15-19
615
0.056
16
18-22
19-23
1100
0.060
21
26-33
27-34
425
0.065
18
11-13
11-14
615
0.062
19
15-18
15-19

14 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

210
0.004
6-7
6-8

315
0.009
8-10
9-11

420
0.015
11-13
11-13

525
0.024
13-16
13-16

630
0.035
10
15-18
15-19

735
0.047
16
17-21
18-22

840
0.062
20
19-23
20-24

14 Dia.

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

210
0.005
5-6
5-6

315
0.012
7-9
8-9

420
0.021
9-11
10-12

525
0.034
11-13
12-14

630
0.048
15
13-16
13-16

735
0.066
20
15-18
15-19

840
0.086
25
16-20
17-21

6 Dia.

15 x 37

10 Dia.

18 x 60

12 Dia.

21 x 79

16 Dia.

24 x 24

10 Dia.

24 x 36

12 Dia.

30 x 24

PERFORMANCE DATA

200

11 x 25

24 x 48

T64

Neck Velocity

Inlet Size

Displacement Ventilation

PERFORMANCE DATA

Unit Size
(W x H)

Inlet Size

30 x 36

16 Dia.

30 x 48

16 Dia.

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

275
0.005
6-8
7-8
275
0.004
6-8
7-8

412
0.010
9-11
9-11
412
0.009
9-11
9-11

550
0.018
12-14
12-15
550
0.015
12-14
12-15

687
0.029
14-17
14-18
687
0.024
14-17
14-18

825
0.041
14
16-20
17-21
825
0.034
11
16-20
17-21

962
0.056
20
18-23
19-23
962
0.047
17
18-23
19-23

1100
0.073
24
20-25
21-26
1100
0.061
21
20-25
21-26

PERFORMANCE NOTES:
The adjacent zone (AZ) is the discharge isovel at 1
above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
DT is the under temperature which is the difference
between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.

Throw values shown are distances in feet for


temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

www.titus-hvac.com | www.titus-energysolutions.com

DVVC (continued)

DVVC

PERFORMANCE DATA

T65

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

Available Model:
DVVC
Corner mount displacement diffusers shall be Titus model
DVVC of the sizes and mounting types shown on the plans
and outlet schedule. DVVC diffusers shall provide a 90
degree air discharge pattern for corner mount applications.
Diffusers shall include integral variable air pattern controllers
for adjustment of airflow spread pattern. Air pattern
controllers shall be adjustable, reversible, and removable.
Diffusers shall include an air volume measurement outlet
to facilitate balancing. K-factor shall be marked on diffuser.
Diffusers shall include an internal perforated baffle to
equalize airflow across the face. Internal perforated baffle
shall be round perforated galvanized metal with 51% free
area.
DVVC diffusers shall have a perforated face plate with round
perforations. Diffuser face plate shall be removable for easy
access to internal air pattern controllers.

DVVC
XXXX

16
14
12
10
8
6
5
XX
Inlet Size

Optional accessories shall include telescopic duct cover and


mounting base.
The manufacturer shall provide published performance data
for DVVC displacement diffusers. Diffusers shall be tested in
accordance with European standard Nordtest method.

16 inlet
14 inlet
12 inlet

Unit Size

Finish

MB2
MB1
DC
O

XX

XX

XXXX

10 x 25

26
X

10 inlet
8 inlet
6 inlet
5 inlet

11 x 25

SPECIFICATIONS

The finish shall be #26 white powdercoat paint with a baked


on finish. Paint thickness shall be 2.5 3.5 mils. Paint must
pass the ASTM D 3363 pencil hardness test with a minimum
pencil hardness of H 2H. The paint must pass a 1000
hour ASTM B117-97 Corrosive Environments Salt Spray test
without creepage, blistering, or deterioration of film. The
paint must pass the adhesion cross hatch test ASTM D 3359.

MODEL NUMBER SPECIFICATION

Model

T66

Diffuser face plate, side plates, back panel, top panel,


bottom panel, and air pattern controllers plate shall be
constructed of galvannealed material. Internal perforated
baffle shall be constructed of G-90 22 gauge galvanized
metal material.

13
15
18
21
24
24
24
30
30
30

x
x
x
x
x
x
x
x
x
x

37
37
60
79
24
36
48
24
36
48

White
Special

Accessories

Mounting Base 4
Mounting Base 2 3/4
Duct Cover
None

Displacement Ventilation

Available Model:
DVCP

Material is galvanized
steel and aluminum.
Standard finish
is #26 white
(powdercoat).

Designed to supply a large volume of air


at low velocity to the occupied zone.

Mounting base and


telescopic duct
cover are available
as accessories.

Includes integral variable air pattern controllers for


easy adjustment of the airflow spread pattern.
Includes air volume measurement outlet to
facilitate balancing. K-factor is marked on outlet.

DVCP

Circular displacement diffuser with 360B air


discharge pattern for floor installation.

www.titus-hvac.com | www.titus-energysolutions.com

Circular Displacement Diffuser


DVCP

T
D

3 14 "

Inlet
Size

DVCP

5
6
8
10
12
16
20
24

Nominal
Unit Size
11
12
14
16
18
22
26
31

x
x
x
x
x
x
x
x

24
24
36
36
59
79
79
79

Unit Dimensions (inches)


A
B
D
24
4 7/8
10 7/16
11 13/16
24
5 7/8
3
3
13 /8
35 /4
7 7/8
3
3
15 /8
35 /4
9 7/8
15
3
17 /16
59 /8
11 7/8
1
1
21 /4
78 /4
15 7/8
1
1
25 /4
78 /4
19 7/8
5
1
30 /16
78 /4
23 7/8

All dimensions are in inches.

DVCP

Model

T67

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

ACCESSORIES

Optional telescopic duct cover

Unit Size

Diffuser height with


duct cover kit*
Min
Max

11 x 24

91 9/16

12 x 24

91 9/16

14 x 36

83 12/16

16 x 36

83 12/16

18 x 59

90 12/16

123

/16

22 x 79
26 x 79

109 1/4

31 x 79

*Height dimensions do not include mounting base.

T
View with face removed showing integral
variable air pattern controllers

Optional mounting base


Height (J): 2-3/4 or 4

ACCESSORIES

T68

For detailed instructions on how to change the adjacent zone


using the variable air pattern controllers, refer to page T77.

All dimensions are in inches.

Displacement Ventilation

PERFORMANCE DATA

Unit Size
(W x H)

Inlet Size

12 x 24

6 Dia.

14 x 36

8 Dia.

16 x 36

10 Dia.

18 x 59

12 Dia.

22 x 79

16 Dia.

26 x 79

20 Dia.

31 x 79

24 Dia.

PERFORMANCE NOTES:

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

38
0.003
2-2
2-2
68
0.003
3-3
3-3
106
0.004
4-4
4-4
154
0.003
5-5
5-5
275
0.003
7-7
8-8
431
0.003
9-9
10-10

56
0.007
3-3
3-3
101
0.007
4-4
4-4
160
0.008
5-5
6-6
231
0.007
6-6
7-7
412
0.007
9-9
10-10
646
0.008
11-11
13-13

75
0.013
3-3
3-3
135
0.013
4-4
5-5
213
0.014
6-6
7-7
308
0.013
7-7
8-8
550
0.013
10-10
12-12
862
0.014
14-14
15-15

94
0.020
4-4
4-4
169
0.020
5-5
6-6
266
0.022
7-7
8-8
385
0.020
8-8
9-9
687
0.020
12-12
14-14
1077
0.022
16-16
18-18

113
0.028
4-4
5-5
203
0.029
6-6
6-6
319
0.032
8-8
9-9
461
0.028
9-9
11-11
825
0.029
13-13
15-15
1293
0.031
13
18-18
20-20

132
0.039
4-4
5-5
237
0.040
6-6
7-7
372
0.043
8-8
9-9
538
0.039
10
10-10
12-12
962
0.039
14
15-15
17-17
1508
0.042
18
19-19
22-22

151
0.051
5-5
5-5
271
0.052
7-7
8-8
425
0.056
13
9-9
10-10
615
0.051
15
11-11
13-13
1100
0.051
19
16-16
18-18
1724
0.055
23
21-21
24-24

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

622
0.004
11-11
12-12

933
0.008
14-14
16-16

1244
0.015
17-17
19-19

1554
0.023
19-19
22-22

1865
0.033
16
22-22
25-25

2176
0.045
21
24-24
27-27

2487
0.058
26
26-26
30-30

L=W
L=W

DVCP

Throw values shown are distances in feet for


temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

PERFORMANCE DATA

The adjacent zone (AZ) is the discharge isovel at 1


above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
DT is the under temperature which is the difference
between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.

www.titus-hvac.com | www.titus-energysolutions.com

DVCP

T69

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS
Available Model:
DVCP
Circular displacement diffusers shall be Titus model DVCP
of the sizes and mounting types shown on the plans
and outlet schedule. DVCP diffusers shall provide a 360
degree air discharge pattern for floor installation. Diffusers
shall include integral variable air pattern controllers for
adjustment of airflow spread pattern. Air pattern controllers
shall be adjustable, reversible, and removable. Diffusers
shall include an air volume measurement outlet to facilitate
balancing. K-factor shall be marked on diffuser. Diffusers
shall include an internal perforated baffle to equalize airflow
across the face. Internal perforated baffle shall be round
perforated galvanized metal with 51% free area.
DVCP diffusers shall have a perforated face plate with
round perforations. Diffuser face plate shall be removable
for easy access to internal air pattern controllers.

controllers plate shall be constructed of galvannealed


material. Internal perforated baffle shall be constructed of
G-90 22 gauge galvanized metal material.
The finish shall be #26 white powdercoat paint with a
baked on finish. Paint thickness shall be 2.5 3.5 mils.
Paint must pass the ASTM D 3363 pencil hardness test with
a minimum pencil hardness of H 2H. The paint must pass
a 1000 hour ASTM B117-97 Corrosive Environments Salt
Spray test without creepage, blistering, or deterioration
of film. The paint must pass the adhesion cross hatch test
ASTM D 3359.
Optional accessories shall include telescopic duct cover and
mounting base.
The manufacturer shall provide published performance data
for DVCP displacement diffusers. Diffusers shall be tested in
accordance with European standard Nordtest method.

Diffuser face plate, top panel, bottom panel, and air pattern

MODEL NUMBER SPECIFICATION

Model
DVCP
XXXX

24
20
16
12
10
8
6
5
XX
Inlet Size

24 inlet
20 inlet
16 inlet
12 inlet
8 inlet
6 inlet
5 inlet

Unit Size

Finish

XXXXX

XX

11 x 24

26
X

12 x 24

SPECIFICATIONS

14
16
18
22
26
31

T70

MB2
MB1
DC
O

10 inlet

x
x
x
x
x
x

36
36
59
79
79
79

XXX
White
Special

Accessories

Mounting Base 4
Mounting Base 2 3/4
Duct Cover
None

Displacement Ventilation

A single blade damper rotates


to shut off the front (cooling)
or rear (heating) plenum. The
damper is driven by a 24 volt
motor/actuator that provides
the auto-changeover action for
the cooling/heating applications
(transformer by others).
Available in two sizes: 36x79
with 14 diameter inlet,
47x79 with 24 x 8 inlet.

Optional duct cover and mounting


base available as accessories.
Material is galvanized
steel and aluminum.

Cooling Mode

The dual plenum design features


a front plenum ducted to a
displacement diffuser at the top
and rear plenum ducted to a CT
diffuser at the bottom of the unit.

The DVRI-HC uses displacement


principles to cool and mixed
airflow principles to heat
from a single unit assembly
with one inlet connection.

All dimensions are in inches.

DVRI-HC PLEXICON

Heating Mode

The Titus DVRI-HC Plexicon


is a combination displacement/
mixed air diffuser that can be
positioned against a wall in flush
or surface mount applications to
provide cooling and perimeter
heating in the space.

DVRI-HC Plexicon

Available Models:

DVRI-HC 14

DVRI-HC 32

www.titus-hvac.com | www.titus-energysolutions.com

Heating & Cooling Options


DVRI-HC Plexicon

T71

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS - DVRI-HC 14
D

G
C

A
3 1/4

L
B

Model

Inlet
Size

Nominal
Unit Size

DVRI-HC

14

36 x 79

A
36

B
78 3/8

Unit Dimensions (inches)


C
D
G
16 5/16
13 7/8
7 5/8

L
65 1/4

Optional telescopic duct cover

Model

Unit Size

Diffuser height with


duct cover kit*
Min
Max

DVRI-HC

36 x 79

109 7/8

124

DIMENSIONS

*Height dimensions do not


include mounting base.

View with face removed showing integral


variable air pattern controllers
For detailed instructions on how to change the adjacent zone
using the variable air pattern controllers, refer to page T77.
Optional mounting base
Height (J): 2-3/4 or 4

T72

All dimensions are in inches.

Displacement Ventilation

DIMENSIONS - DVRI-HC 32

www.titus-hvac.com | www.titus-energysolutions.com

2 3/4

E
F

L
B

Model

Inlet
Size

Nominal
Unit Size

DVRI-HC

24 x 8

47 x 79

A
46 7/8

B
78 3/8

Unit Dimensions (inches)


C
E
F
16 5/16
23 7/8
7 7/8

H
2

L
65 1/4

Optional telescopic duct cover

Model

Unit Size

Diffuser height with


duct cover kit*
Min
Max

DVRI-HC

47 x 79

109 7/8

124

*Height dimensions do not


include mounting base.

DIMENSIONS

View with face removed showing integral


variable air pattern controllers

For detailed instructions on how to change the adjacent zone


using the variable air pattern controllers, refer to page T77.

Optional mounting base


Height (J): 2-3/4 or 4

All dimensions are in inches.

T73

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DVRI-HC COOLING DATA


Unit Size
(W x H)

Inlet Size

36 x 79

14 Dia.

47 x 79

24 x 8

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

210
0.005
6-5
8-6
261
0.006
7-5
10-6

315
0.011
7-8
11-10
392
0.013
9-8
13-10

420
0.020
9-11
13-13
522
0.024
11
11-11
15-13

525
0.032
10
10-14
15-17
653
0.036
18
13-14
18-17

630
0.046
16
12-17
17-20
783
0.053
24
14-17
20-20

735
0.062
21
13-20
18-24
914
0.071
29
16-20
22-24

840
0.081
25
14-23
20-27
1045
0.092
33
17-23
24-27

PERFORMANCE NOTES:
The adjacent zone (AZ) is the discharge isovel at 1
above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
DT is the under temperature which is the difference
between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.

PERFORMANCE DATA

T74

DVRI - HC

Throw values shown are distances in feet for


temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

Displacement Ventilation

PERFORMANCE DATA

Unit Size
(W x H)

36 x 79

47 x 79

Inlet Size

14 Dia.

24 x 8

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Throw (150-100-50 fpm)
at D15BF
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Throw (150-100-50 fpm)
at D15BF

210
0.011
-

315
0.024
-

420
0.042
11

525
0.066
18

630
0.095
24

735
0.130
28

840
0.169
33

3-4-8

4-6-12

6-8-16

7-10-17

261
0.010
-

392
0.023
-

522
0.041
14

653
0.065
21

3-5-9

5-7-14

6-9-17

8-12-19

8-12-19 10-15-21 11-16-22


783
0.093
27

914
0.127
32

1045
0.166
36

9-14-21 11-16-23 12-17-25

PERFORMANCE NOTES:
Data obtained from tests conducted in accordance
with ANSI/ASHRAE Standard 70-2006.
Throw values are given for terminal velocities of
150, 100, and 50 fpm at a DT of 15 F. The DT is the
difference in the supply air and room air temperature.
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.

Each NC value represents the noise criteria curve


which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) is space denotes an NC value of less than 10.
All pressures are given in inches of water.

www.titus-hvac.com | www.titus-energysolutions.com

DVRI-HC HEATING DATA

PERFORMANCE DATA
T75

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

Available Models:
DVRI-HC 14
DVRI-HC 32

DVRI-HC diffusers shall have a perforated face plate with


round perforations. Diffuser face plate shall be removable
for easy access to internal air pattern controllers.

Rectangular displacement diffusers shall be Titus model


DVRI-HC of the sizes and mounting types shown on the
plans and outlet schedule. DVRI-HC diffusers shall provide
a 1-way air discharge pattern from the face of diffuser
for flush mount or surface mount applications. Diffusers
shall include integral variable air pattern controllers for
adjustment of airflow spread pattern. Air pattern controllers
shall be adjustable, reversible, and removable. Diffusers
shall be a dual plenum design with one supply air inlet.
Each diffuser shall have a rear plenum ducted to a Titus CT
diffuser at the bottom of the unit and a front plenum ducted
to a DVRI diffuser at the top section. Diffusers shall have a
24V motor/actuator assembly to power the auto-changeover
action. Diffusers shall include an air volume measurement
outlet to facilitate balancing. K-factor shall be marked on
diffuser. Diffusers shall include an internal perforated baffle
to equalize airflow across the face. Internal perforated baffle
shall be round perforated galvanized metal with 58% free
area.

Diffuser face plate, side plates, back panel, top panel,


bottom panel, and air pattern controllers plate shall be
constructed of galvannealed material. Internal perforated
baffle shall be constructed of G-90 22 gauge galvanized
metal material.
The finish shall be #26 white powdercoat paint with a baked
on finish. Paint thickness shall be 2.5 3.5 mils. Paint must
pass the ASTM D 3363 pencil hardness test with a minimum
pencil hardness of H 2H. The paint must pass a 1000
hour ASTM B117-97 Corrosive Environments Salt Spray test
without creepage, blistering, or deterioration of film. The
paint must pass the adhesion cross hatch test ASTM D 3359.
Optional mounting base shall be offered as an accessory.
The manufacturer shall provide published performance data
for DVRI-HC displacement diffusers. Diffusers shall be tested
in accordance with European standard Nordtest method .

MODEL NUMBER SPECIFICATION

Model
DVRI-HC

32
14

XXXXXX

XX
Inlet Size

Unit Size

Finish

MB2
MB1
O

XXXXX

XX

XXX

36 x 79

26
X

24 x 8 inlet
14 inlet

SPECIFICATIONS

47 x 79

T76

White
Special

Accessories

Mounting Base 4
Mounting Base 2 3/4
None

Displacement Diffuser Adjustment

Displacement Ventilation

This unique feature provides a high level of flexibility for


the end user. They can react to changes in the space by
adjusting the adjacent zone rather than disconnecting and
moving the diffuser. Illustration 3 shows a conference room
with displacement diffusers and the standard adjacent zone
from the factory. Illustration 4 shows how these adjacent
zones can be changed to accomodate the needs in the
space.

Illustration 1. Cutaway of Displacement Diffuser

www.titus-hvac.com | www.titus-energysolutions.com

All Titus Displacement diffusers feature integral variable air


pattern controllers located in the unit behind the perforated
face (see illustration 1). These pattern controllers can be
removed and repositioned to change the adjacent zone
pattern from the diffuser face. To adjust the pattern: (see
illustration 2).
Remove diffuser face.
Remove louvers.
Reposition louvers.
Replace face.

T
Illustration 3. Standard Air Patterns

Illustration 4. Adjusted Air Patterns

DIFFUSER ADJUSTMENT

Illustration 2. Adjust the pattern

T77

Displacement Ventilation

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DVRI-HCS COOLING DATA


Unit Size
(W x H)

Inlet Size

36 x 79

14 Dia.

47 x 79

24 x 8

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Adjacent Zone (AZ) D5B
Adjacent Zone (AZ) D10B

210
0.005
7-5
10-6
261
0.006
9-5
13-6

315
0.011
9-7
12-9
392
0.013
11-7
16-9

420
0.020
10-10
15-12
522
0.024
11
13-10
18-12

525
0.032
10
11-13
17-15
653
0.036
18
14-13
21-15

630
0.046
16
13-15
18-18
783
0.053
24
16-15
23-18

735
0.062
21
14-18
20-21
914
0.071
29
17-18
25-21

840
0.081
25
15-20
22-24
1045
0.092
33
19-21
27-25

PERFORMANCE NOTES:
The adjacent zone (AZ) is the discharge isovel at 1
above the floor where the terminal velocity is 50 fpm.
Adjacent zone dimensions were obtained from tests
conducted in accordance with Nordtest method of
aerodynamic testing and rating of low velocity.
Sound and pressure data were obtained
from tests conducted in accordance with
ANSI/ASHRAE Standard 70-2006.
DT is the under temperature which is the difference
between room air temperature at 3-1/2 ft above
the floor and the supply air temperature.

PERFORMANCE DATA

T78

DVRI - HC

Throw values shown are distances in feet for


temperature differentials of 5BF DT and 10BF DT cooling
at 50 fpm terminal velocity. The first listed throw value
corresponds to the length and the second throw.
value to the width (see diagram at bottom of page)
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.
Each NC value represents the noise criteria curve
which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) in space denotes an NC value of less than 10.
All pressures are given in inches of water.

Displacement Ventilation

PERFORMANCE DATA

Unit Size
(W x H)

36 x 79

47 x 79

Inlet Size

14 Dia.

24 x 8

Neck Velocity

200

300

400

500

600

700

800

Velocity Pressure

0.002

0.006

0.010

0.016

0.022

0.031

0.040

Airflow, cfm
Total Pressure
NC (Noise Criteria)
Throw (150-100-50 fpm)
at D15BF
Airflow, cfm
Total Pressure
NC (Noise Criteria)
Throw (150-100-50 fpm)
at D15BF

210
0.011
-

315
0.024
-

420
0.042
11

525
0.066
18

630
0.095
24

735
0.130
28

840
0.169
33

3-4-8

4-6-12

6-8-16

7-10-17

261
0.010
-

392
0.023
-

522
0.041
14

653
0.065
21

3-5-9

5-7-14

6-9-17

8-12-19

8-12-19 10-15-21 11-16-22


783
0.093
27

914
0.127
32

1045
0.166
36

9-14-21 11-16-23 12-17-25

PERFORMANCE NOTES:
Data obtained from tests conducted in accordance
with ANSI/ASHRAE Standard 70-2006.
Throw values are given for terminal velocities of
150, 100, and 50 fpm at a DT of 15 F. The DT is the
difference in the supply air and room air temperature.
NC values based on octave band 2 to 7 sound
power levels minus a room absorption of 10 dB.

Each NC value represents the noise criteria curve


which will not be exceeded by the sound pressure
in any of the octave bands, 2 through 7, with a
room absorption of 10 dB, re 10-12 watts.
Dash (-) is space denotes an NC value of less than 10.
All pressures are given in inches of water.

www.titus-hvac.com | www.titus-energysolutions.com

DVRI-HCS HEATING DATA

PERFORMANCE DATA
T79

Notes

Displacement Ventilation

chilled beam

U
www.titus-hvac.com | www.titus-energysolutions.com

www.titus-hvac.com | www.titus-energysolutions.com

Table of Contents

Chilled Beam

chilled beam products


Chilled Beam Products...................................................................................................................................................................U3

overview
Overview.........................................................................................................................................................................................U5
Application Guide...........................................................................................................................................................................U6
Introduction............................................................................................................................................................................U6
History.....................................................................................................................................................................................U6
Theoretical Background..........................................................................................................................................................U7
Benefits of Chilled Ceiling Systems........................................................................................................................................U9
Chilled Ceiling System Design..............................................................................................................................................U10
System Design Process.........................................................................................................................................................U12

linear active chilled beams


DISA..............................................................................................................................................................................................U18
Dimensions...........................................................................................................................................................................U21
Performance Data.................................................................................................................................................................U29
DISA-V..........................................................................................................................................................................................U35
Dimensions...........................................................................................................................................................................U37
Performance Data.................................................................................................................................................................U39
Suggested Specifications [DISA, DISA-V].............................................................................................................................U40
LCBS.............................................................................................................................................................................................U43
Dimensions...........................................................................................................................................................................U45
Performance Data.................................................................................................................................................................U47
Suggested Specifications......................................................................................................................................................U49

thermal comfort modules


TCM2............................................................................................................................................................................................U51
Dimensions...........................................................................................................................................................................U53
Performance Data.................................................................................................................................................................U55
Suggested Specifications......................................................................................................................................................U57

linear passive chilled beams

CHILLED BEAM

SPB...............................................................................................................................................................................................U59
Dimensions...........................................................................................................................................................................U61
Performance Data.................................................................................................................................................................U63
Suggested Specifications......................................................................................................................................................U66

radiant ceiling products


Alpety FKL, HKL............................................................................................................................................................................U67
Dimensions...........................................................................................................................................................................U68
Performance Data.................................................................................................................................................................U69
Alpety SKS....................................................................................................................................................................................U71
Dimensions...........................................................................................................................................................................U72
Suggested Specifications [Alpety FKL, HKL, & SKS..............................................................................................................U73

U2
Titus by Schako

Chilled Beam

Chilled Beam Products

DISA

DISA-V

LCBS

ACTIVE CHILLED BEAM


DIFFUSER

SIDEWALL CHILLED BEAM


DIFFUSER

ACTIVE CHILLED BEAM


DIFFUSER

1-way or 2-way throw pattern that


is available in variable lengths.
For use in heating or cooling applications
and perfect for open office environments.

Horizontal throw pattern that is


available in variable lengths.
For use in heating or cooling applications
in either a 2-pipe or 4-pipe system.

1-way throw pattern that is available


in a fixed length at 4 feet.
Available with a dew-point safety pan.

www.titus-hvac.com | www.titus-energysolutions.com

LINEAR ACTIVE CHILLED BEAMS

pages: U14-U45

U
THERMAL COMFORT MODULES

pages: U47-U53

TCM2



CHILLED BEAM

MODULAR ACTIVE CHILLED BEAM


4-way throw pattern similar to a traditional ceiling diffuser.
Works well in heating & cooling applications.
Modular design provides the highest level of comfort in the occupied space.
Available with a dew-point safety pan.

U3
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

Chilled Beam Products (continued)

LINEAR PASSIVE CHILLED BEAMS

pages: U55-U62

SPB
PASSIVE CHILLED BEAM
Available in a variety of lengths.
Produces low noise levels.
Product can be mounted flush with the ceiling or suspended below the ceiling for exposed applications.

U
RADIANT CEILING PRODUCTS

CHILLED BEAM

pages: U63-U69

ALPETY FKL

ALPETY HKL

ALPETY SKS

RADIANT CEILING SYSTEMS

RADIANT CEILING SYSTEMS

RADIANT CEILING SYSTEMS

Water driven.
Low energy consumption and noise levels.
Creates a high degree of thermal comfort
through draft free cooling and even
temperature distribution in the space.

Water driven.
Low energy consumption and noise levels.
Creates a high degree of thermal comfort
through draft free cooling and even
temperature distribution in the space.

Water driven.
Low energy consumption and noise levels.
Creates a high degree of thermal comfort
through draft free cooling and even
temperature distribution in the space.

U4
Titus by Schako

Overview

The chilled ceiling products provide sensible cooling and


heating to the space by utilizing the more efficient heat
transfer capacity of water, as opposed to air. This decouples
the latent and sensible loads, reducing the energy cost of
sensible cooling. With passive beams and radiant products,
an additional system is necessary to meet the ventilation
and latent cooling needs of the space. The Titus active
chilled beams integrate the supply of ventilation air creating
an active diffuser. Using the ventilation air to pressurize
a plenum with aerodynamically designed nozzles, high
velocity jets of air are created forcing induction of room air
over the water coils integral to the units. Forced induction
dramatically improves the heating and cooling capacity over
passive beams and radiant products. Titus active chilled

beams harness the energy of the supply air to further


reduce total energy consumption.
Titus offers a chilled ceiling product to meet the
requirements of any design or installation. Just a single
model of passive beam accommodates both exposed and
recessed mounting applications. Active chilled beams are
available in 1, 2, and 4-way throw patterns. There is even
a model for high sidewall applications. In addition to the
variety of product solutions available, the appearance of the
units can be customized through standard options, which
enables seamless integration into any architectural style,
traditional or contemporary.

www.titus-hvac.com | www.titus-energysolutions.com

The Titus chilled ceiling product line is comprised of chilled


beams, both active and passive, radiant ceiling panels, and
radiant sails. These products offer optimized performance
and provide high levels of thermal comfort for the occupant.
In addition to increased occupancy comfort, use of the
chilled ceiling products reduce the amount of energy
required to heat and cool a building.

Chilled Beam

CHILLED BEAM
U5
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE

Introduction
Chilled ceiling systems consist of three main product types:
active chilled beams, passive chilled beams, and radiant
ceiling panels/sails. Even though these units are commonly
referred to as chilled products they are also effectively
used for both cooling and heating.
Both active and passive beams utilize water coils to
provide sensible cooling, reducing the total load that must
be addressed through the buildings air handlers. Since
chilled beams provide sensible only cooling they are best
suited for spaces with low to moderate latent loads. This
offers considerable potential for energy savings due to the
volumetric heat transfer capacity of water and trade-off
between fan energy and pumping power.

Radiant ceilings systems emit heating and cooling by both


convection and radiation. During cooling, ambient air near
the ceiling cools and falls to the occupied area, due to its
higher density. The ceiling panels emit cooling and heating
to the surrounding surfaces in the area by radiation. Radiant
heat transfer typically results in high thermal comfort since
the ambient temperature will feel 2.5BF to 5BF cooler/
warmer than actual room temperature. This effect has the
advantage that the room requires less conditioning than a
traditional system, introducing an additional opportunity for
energy savings.

Passive beams consist of a water coil and an enclosure. The


enclosure is primarily cosmetic, but helps to maintain even
heat transfer across the coil. Passive beams provide cooling
primarily through convective heat transfer. A convection
current is created where higher density cool air sinks into
the space, inducing warm low density air at the ceiling level
through the coil. When using passive beams ventilation air
must be introduced to the space either through natural or
mechanical means.

History

APPLICATION GUIDE

Modern chilled ceiling systems, more specifically


active chilled beams, got their start in the 1920s
when Willis Carrier began to develop the concepts for
under-sill induction units. Patents were applied for
and first installations of these units were completed
in 1940. The use of an air-water terminal located in
the space was an important advance in and of itself;
however, these systems solidified the advantages
of an air-water system over an all-air system.

U6

Incorporating supply air into a beam creates an active


diffuser. Ventilation air pressurizes a plenum and the
aerodynamically designed jets induce room air over water
coils. Forced induction dramatically increases the heating
and cooling capacity per square foot, compared to passive
beams and radiant products. Active chilled beams harness
the energy of the supply air to further reduce total energy
consumption.

Water is much more efficient heat


transfer medium than air.
Reduced duct size required to only supply
ventilation air increased usable space, and reduced
the material cost and installation time.
Scandinavian engineers, during the mid-1970s, adapted
this technology along with radiant heating/cooling
panels for overhead applications to work with new
buildings designed to utilize natural ventilation. The
result of their efforts was the passive chilled beam.
In regions where using natural ventilation was not effective,
engineers integrated the mechanical ventilation into chilled
beam. Utilizing the same principles used in the under-sill
induction boxes, the active chilled beam was developed.

Chilled Beam

APPLICATION GUIDE

HEAT TRANSFER

ASHRAE defines heat transfer as the flow of heat energy


induced by a temperature difference.
Thermal energy can be transferred or be affected by:
Conduction
Convection
Radiation
Humidity
Thermal conduction is the mechanism of heat transfer by
the transfer of kinetic energy between particles or groups of
particles at the atomic level.
With solid bodies, such as with an air jet near a window,
thermal conduction dominates only very close to the solid
surface.
Thermal convection is the transfer by eddy mixing and
diffusion in addition to conduction.
The transfer of fluid currents produced by external sources,
such as by a blower, is called forced convection.
When the fluid air movement is caused by the difference
in density and the action of gravity, it is called natural
convection. Natural convection is very active near windows
and near heat sources in the occupied spaces. The colder air
falls and the warmer air rises.
Radiant heat transfer takes place through matter. It is a
change in energy form, from internal energy at the source
to electromagnetic energy for transmission, then back to
internal energy at the receiver. Examples of radiation are
sunshine through the air and window to the inside floor or
ceiling light to occupants and to the floor.
All of these methods of heat transfer effect a persons
comfort reaction. In addition, humidity has some effect
caused by a change in evaporation rate from the body.

Heat loss is measured in BTU which is the amount of heat


required to raise 1 lb. of water 1BF. Coefficients used to
estimate the value of the heat loss include:
K Factor: amount of heat transferred in 1
hour through 1 sq. ft. of material, 1 thick
at 1BF of temperature difference.

Equation 1: For a structure with multiple skin materials, the


total heat transmission can be calculated as:

U = 1/(R1 + R2 + ..Rn)
For hydronic heating and cooling systems heat is removed
from the occupied space (cooling) or added to the occupied
space (heating) via a closed loop water system. Return air
from the space passes across a fin tube coil.

PSYCHROMETRICS

One of the four major elements of thermal energy and


comfort is humidity. Psychrometrics uses thermodynamics
properties to analyze conditions and processes involving
moist air. A detailed study of psychrometrics can be found in
Chapter 1 of ASHRAE 2009 Fundamentals Handbook. This
section is a summary of how knowledge of psychrometrics
can be used to maximize space comfort and system
performance.

Atmospheric Air (the air that you breathe), contains


many gaseous components including water vapor and
containments. Dry Air is atmospheric air with all moisture
removed and is used only as a point of reference. Moist
Air is a combination of dry air and water vapor and can be
considered equal to atmospheric air for this discussion.
A psychrometric chart (FIGURE 4) is a graphical
representation of the thermodynamic properties of moist
air. There are several charts available to cover all common
conditions. The one shown here is taken from ASHRAE
Fundamentals Handbook, Chapter 1 and illustrates
conditions of 32 to 100BF at sea level.
The Dry-bulb Temperature (DBT), is the temperature
measured using a standard thermometer. Dry-bulb is also
known as the sensible temperature.
The Wet-bulb Temperature (WBT), is the temperature
measured using a wetted thermometer. Wet-bulb is used to
determine the moisture content of air.
The Absolute Humidity (AH), is the vapor content of air. It is
described in terms of moisture per lb of dry air or grains of
moisture per lb. of dry air. AH is also referred to as moisture
content or humidity ratio. There are 7000 grains in a lb. of
water.
The Relative Humidity (RH), is the vapor content of air. It is
described as the percentage of saturation humidity at the

APPLICATION GUIGE

Heat transfer is also affected by the following factors:


A greater temperature difference will result
in a greater amount of heat transfer.
The amount of surface area is directly
proportional to the amount of heat transfer.
The amount of time is also directly proportional
to the amount of heat transfer.
The thermal resistance of the material
use affects the rate of heat transfer.

C Factor: amount of heat transferred in 1


hour through 1 sq. ft. of material through the
specified thickness of the material used.
R Value: resistance to heat transfer, measured
as the reciprocal of conductance (1/K or 1/C).
U Value: designates the overall transmission
of heat in 1 hour per sq. ft. of area for the
difference of 1BF across specified material.
Conductance of individual materials is not directly
applicable to the heat loss calculation. First, it must
be converted to the R value, which is (1/K or 1/C).

www.titus-hvac.com | www.titus-energysolutions.com

Theoretical Background

U7

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE
same temperature (%). The goal for optimum space comfort
is 30-35% for heating conditions, and 45-60% for cooling
conditions. Saturation humidity is the maximum vapor
content (lb./lb.) per lb. dry air that air can hold at a fixed
temperature.

increase in specific volume.


The Enthalpy (H) is the heat content of air. Enthalpy is also
known as the total heat of air. Enthalpy is defendant on the
wet-bulb temperature of air. It is described in terms of Btus
per lb. dry air (Btu/lb.).

The Dew Point Temperature (DPT), is the temperature at


which vapor begins to fall out of air to form condensation.
DPT is the temperature at which a state of saturation
humidity occurs, or 100% RH. It is also known as the
saturation temperature.

A Status Point is a location on the psychrometric chart


defined by any two psychrometric properties. A hydrometer
or psychrometer is commonly used to define a status point.
At 100% RH the wet-bulb will equal the dry-bulb
temperature. As the temperature difference between
temperatures increases, the RH will decrease.

The Specific Volume (Spv), is the reciprocal of air density


which is described in terms of cubic feet per lb of dry air
(cu ft/lb.). An increase in air temperature will result in a
decrease in density and an increase in volume. A decrease
in atmospheric pressure also decreased air density while
increasing volume. At 5000 feet above sea level, density is
decreased by 17%. Higher altitudes require larger motors
and blowers to move the same effective mass, due to the

To locate a status-point, find the dry-bulb temperature


on the bottom of the psychrometric chart. Follow this line
upward until it intersects with the wet-bulb temperature
from the left side of the chart.

55

60

90

50

.028

Sensible Heat Ratio


1.0

1.0

5000

0.6
0.5

Sensible Heat
Total Heat

Qs
Qt

3000

0.4

-1

2.0
4
8.0.0
:
-48.0
-2 .0
.0

85

-2000
-1000

15.0

0.8

85

20

00

0.1

.5
-0 .4
-0
3
-0.

00

-0.1

15

tB

ulb

.024

Te

mp

55

era

tur

40

e,

.022

80

1000
Enthalpy
Humidity Ratio

We

80

50

-0.2

0.2

0.

.0

.026

45

Dh
DW

60

.020

75

35

50
14.5

.018

,
re
tu
ra

nd

pe

ou

rP

Te

pe

tio

tu

Sa

Dry Bulb Temperature, F

20%

10

15

105

100

95

90

85

80

75

Humidity
70

65

60

55

50

45

40

35

12.5

10% Relative

20
Enthalpy - Btu per Pound of Dry Air

U8

Figure 4. Psyochrometric Chart

.010

40

.008

.006

35
.004

.002

115

30%

110

40%

40

35

ir

50%

45

ry A
.D

35

50

60

13.5

45
40

er lb

55

ft. p

%
70
50

Humidity Ratio - Pounds Moisture per Pound Dry Air

cu.

60

120

80

55

e-

lum

Vo

20

.012

65

%
90

14.0

60

15

45

tu

25

13.0

APPLICATION GUIDE

.014

ra

-B
y
lp

70
65

En

th
a

.016

30

of

ry

ir

75

70

30

Chilled Beam

APPLICATION GUIDE

When will condensation occur? To determine if a supply


air duct or air outlet device will form condensation on the
surface:
First, using the R-value of any thermal barrier, determine the
minimum surface temperature.
Next, determine the DPT of the atmospheric air in contact
with the surface.
If the surface temperature is equal or lower than the DPT,
the surface will form condensation. If yes, an additional
thermal barrier or other condensation prevention strategies
may be required to solve the problem.
Sensible heating (Qsen), is the heat that raises the dry-bulb
temperature of air without increasing the moisture content.
Because we can easily sense this change in temperature, it
is called sensible. Sensible cooling is the removal of heat
without removing moisture content of the air.
Latent Heat (Qlat), is the heat content of air due to the
presence of water vapor. Latent heat is the heat required
to evaporate this same amount of water (970 Btu/lb), also
known as the latent heat of vaporization. As latent heat
increases, moisture content increases.
Water can be heated to 212BF. If more heat is added, the
water will vaporize but the temperature will not change.
Latent Cooling (Qlat), is the removal of latent eat from air
without lowering the dry-bulb temperature. To retrieve 1
lb. of condensate, 970 Btus would need to be removed. As
latent heat decreased, moisture content decreases.\

Sensible processes can be shown as horizontal paths on


a psychrometric chart. Latent processes can be shown as
vertical paths on a psychrometric chart. Most processes
include both, resulting in an angled or diagonal path.
Sensible heat factor (SHF) is the measure of sensible heat to
latent heat. Sensible heating only is 1.0. Equal proportions
result in 0.5. SHF is generally higher than 0.5 because of
the cooling processes that remove more sensible heat than
latent heat.

INDUCTION

Induction is a flow that occurs as a result of the change


in velocity pressure as a jet of air expands. The principals
of induced air flow are based on the Venturi effect. The

Benefits of Chilled Ceiling Systems


Chilled Ceiling Systems are designed to provide superior
occupancy comfort. These systems require less energy
to operate, operate more efficiently, and use less
materials than conventional all air systems. Tempered and
dehumidified air is supplied to the space to meet ventilation
requirements and to handle the latent load. The majority
of the sensible load is addressed with the chilled ceiling
products. Decoupling the latent and sensible loads takes
advantage of the superior volumetric heat capacity of
water. The reduced volume of air that must be delivered to
the space results in reduced air handler capacity and size,
smaller duct sizes, and overall energy savings. A higher
supply temperature contributes to increased occupancy
comfort.

FIRST COST BENEFITS:

Shallow unit profiles allow for reduced ceiling


space requirements; typically require 60% less
vertical space than conventional all air systems.
"" Reduced slab to slab spacing;
reducing material costs per floor.
"" Easily integrated into retrofit
applications where space is limited.
Low volume of supply air required for active beams
enables reduction of the total amount of air processed
at the air-handler by an all air system up to 50%.
"" Reduced air-handler size/
capacity, and duct work size

COMFORT AND IAQ BENEFITS:

Active beams typically supply a constant volume


of primary air, decreasing occurrences of dumping
and changes to the air motion in the space;
issues common to typical VAV systems.
When supplied with primary air from a
dedicated outside air system (DOAS) 100%
fresh air is supplied to the space.
Dry-coil sensible cooling, eliminates bacterial,
fungal, or mold growth associated with fan coils
and other unitary products with condensing coils.
Constant primary air volume ensures ventilation
requirements are met and helps to maintain
relative humidity levels in the space.

APPLICATION GUIGE

Latent Heat of Fusion is the heat required to change a liquid


into a solid (144 Btu/lb. Water can be cooled to 32BF. If
more heat is removed, it will cause ice to form. To retrieve 1
lb of water from ice, 144 Btus must be added.

Venturi effect is a derivation of Bernoullis principle and


the continuity laws. In order to satisfy the fluid dynamic
principles of continuity, a fluids velocity must decrease
as the flow expands; at the same time the static pressure
of the flow must increase. The increase in static pressure
balances the decreased velocity, thus maintaining the
principles of conservation.

www.titus-hvac.com | www.titus-energysolutions.com

From the status point you can locate:


Absolute Humidity (AH)
Relative Humidity (RH)
Dew Point Temperature (DPT)
Specific Volume (Spv)

ENERGY EFFICIENCY AND OPERATIONAL BENEFITS:


Utilizing the heat transfer capacity of water also
takes advantage of the superior operational
efficiency of pumps as compared to fans.

U9

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE

"" A 1-inch diameter pipe can deliver


the same cooling/heating capacity
as an 18-inch x 18-inch duct
"" Reduction of fan energy by a factor of 7 to
deliver the same cooling to the space.
Higher supply water temperatures
compared to conventional systems allow
for use of water side economizers.
"" Increased opportunities for free-cooling.
Significant reduction in maintenance costs and
labor as compared to conventional all air systems
"" No moving parts - no blowers, motors,
damper actuators to replace
"" Dry-coil operation - does not require regular
cleaning and disinfecting of condensate pans
"" Recommend cleaning of coils once every 4 to
5 years, more frequently in hospitality rooms
where linens are frequently changed (i.e.
hospital patient rooms and hotel rooms).

Chilled Ceiling System Design


CHILLED CEILING APPLICATIONS

APPLICATION GUIDE

Chilled beam and radiant ceiling products are designed to


handle high thermal loads in the space. They are also an
effective solution in spaces where individual temperature
control is desired. Ideal applications are spaces where the
sensible heat ratio is greater than 0.75, meaning that 75%
or more of the total heat gains in the space are sensible
gains. These locations include computer/server rooms,
condos/apartments/hotel guest rooms, libraries, and
museums.

U10

Use of chilled ceiling systems should be limited to


applications where cooling loads are less than 40 BTUH/
ft2, and heating loads are lower than 15 BTUH/ft2. More
specifically, passive beam and radiant panel usage should be
limited to applications where cooling loads are no more than
25 BTUH/ft2, and active chilled beams are not recommended
for use when cooling loads are more than 40 BTUH/ft2.
Chilled ceiling systems are not recommended in these
applications since addressing the loads will likely create
thermal comfort issues. In transitional spaces where thermal
comfort is not critical, chilled ceiling products can be used to
address higher loads.
Chilled beams and radiant ceiling systems should not
be applied in buildings where relative humidity of the
space is not easily maintained. This would include retrofit
applications, lobbies, and entrances where there is excessive
infiltration.
Chilled beams are best applied when installed no higher
than 14 feet above the floor, but can remain effective with
installation heights up to 20 feet. When installed above
these heights it is difficult to effectively get heating and
cooling into the occupied space.

PRACTICAL DESIGN GUIDELINES

There are guidelines that should be followed when


considering a chilled ceiling system to ensure the design will
create a comfortable environment for occupants and result
in optimum energy efficiency.
The system should be designed to meet only the heating
and cooling requirements of the actual space. Overdesigning
the system will increase the cost of the project, and
potentially result in decreased comfort.
Primary air must be adequately dehumidified, and supplied
at a flow rate large enough to offset the latent loads of the
space. This flow rate must also be high enough to meet the
ventilation requirements outlined in ASHRAE standard 62.1.
When heating with chilled beams and radiant panels, care
must be taken that the system is not oversized for heating.
Entering water temperatures should be as low as possible to
meet the heating requirements, and should never be over
140BF.
Condensation control strategies must be implemented to
maintain optimum operating conditions, prevent bacterial,
mold, and fungus growth, ensure damage to building does
not occur.
When designing a chilled beam system it is best to limit the
types and configurations of products used. This will help to
make logistics during installation and building maintenance
easier.
Room air temperature is maintained through regulation of
2-way control valves. Use of 2-way valves is preferred as
they will minimize pumping costs.
Systems should be designed to take full advantage of free
cooling and heating opportunities through economizers and
heat recovery devices. Chilled beams and radiant panels
are highly efficient products and offer energy savings over
traditional systems. However, one of the biggest advantages
these products offer is the additional energy savings that
can be achieved in the rest of the system due to the unit
operating conditions.

DESIGN METHODOLOGY

The design of chilled ceiling systems is an iterative process


between selection of the equipment to be used and the inlet
conditions for the system. This also includes placement/
orientation. The iterative process enables the inlet
conditions to be optimized so that the design results in a
comfortable space for the occupant, and that the equipment
is operating with the highest efficiency possible. This is true
for all chilled ceiling systems, but is especially true for active
chilled beams.
Equipment selection is based on the following items and
must be balanced for creating an effective, efficient, and
comfortable system:

Chilled Beam

APPLICATION GUIDE

- Cooling design temperature DB/WB


- Heating design temperature DB

Indoor air quality requirements


- Required ventilation flow rate
- Define allowable humidity level in the space
- Calculate expected infiltration
- Supply air temperature DB/WB
- Verify supply air flow rate meets requirements to handle latent loads
Calculation of required heating and cooling capacity
- Calculation of heat loads
- Calculation of heat losses
- Calculate cooling introduced from supply air
Adjustment to building design parameters
- Decrease external loads and losses; improved solar shading
and window construction
- Improve window and building structure to decrease infiltration

Product selection: type, length, configuration, and design parameters


Chilled Ceiling Product Selection
- Active Chilled Beam
- Passive Chilled Beam + supply air system
- Radiant Panels + supply air system

www.titus-hvac.com | www.titus-energysolutions.com

Space design conditions

Define room design temperature

Entering Water Temperature


- Selected to ensure condensation prevention
Selection of other entering water conditions
- Mean Coil Temperature to room design temperature difference
- Water flow rate
- Maintaining acceptable coil pressure drop
- Ensure turbulent flow conditions
Select product size and configuration
- Beam/Panel size
- Configuration/throw pattern
- Unit cooling/heating capacities
- Supply air flow rate/operating pressure
- Check for occupancy comfort

Product noise level and system operating pressure

Room air control


- Temperature control by regulating water flow rate
- 2-Way valves; on/off or proportional control
- Constant supply air flow; possible unoccupied set back
Air and water distribution
- Supply air dehumidification
- Entering water temperature control
- Economizers: air and water

APPLICATION GUIGE

Design of room controls, water and air distribution, and BMS systems

Building Management system


- Condensation prevention strategies
- Occupied/Unoccupied modes
- Daily start up

Figure 5. Chilled Ceiling Design Methdology

U11

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE

APPLICATION GUIDE

Total unit capacity


"" Size of units
"" Quantity of units
"" Unit Configuration
Supply Air
"" Flow rate
"" Temperature
"" Relative humidity
"" Operating pressure
Entering Water Conditions (cooling & heating)
"" Entering water temperature
"" Flow rate
"" Coil pressure drop
Unit Placement
"" Throw patterns
"" Throw length
Noise
Once the inlet conditions and equipment has been selected,
the controls for the system are selected. The room control
system must be designed to deliver the selected inlet
parameters and maintain the energy efficiency of the
design. The critical points to be maintained are the entering
water conditions as well as the supply air conditions. After
control of the critical points has been established, additional
controls to compensate for changes in space dew point
temperature and occupancy should be considered through a
building management system.
This methodology is depicted in Figure 5, Chilled Ceiling
Design Methodology.

System Design Process


U12

SPACE DESIGN CONDITIONS

The first step in determining the space design conditions


is to define the design temperatures for both heating and

cooling. This should be done by following the guidelines set


in ASHRAE Standard 55 and the chapters on heating and
cooling loads in the ASHRAE Fundamentals Handbook.
Once the design temperatures have been defined, an
iterative process should be used to determine the indoor
air quality requirements, calculating the required capacities
to address the heating/cooling loads, and adjusting the
building design/construction (if applicable).
The indoor air quality (IAQ) requirements include supply air
flow rate, to meet both ventilation requirements and address
the latent loads in the space, determining infiltration, and
defining the maximum allowable humidity level.
Based on the building design and construction, anticipated
infiltration should be calculated. Information on how to
calculate infiltration and how to use infiltration when
calculating heat loads and losses can be found in the
ASHRAE Fundamentals Handbook. The heat loads and
losses calculated associated with infiltration are used in
determining the latent cooling requirements. This will affect
the volume of supply air necessary to maintain the design
humidity levels in the room.
Guidelines for determining the minimum ventilation
requirements are given in ASHRAE Standard 62.1. Criteria
for maximum relative humidity in the space, based on a
humidity ratio of 0.012, is set in ASHRAE Standard 55; for
a room design temperature of 75BF, the maximum relative
humidity is 63.5%. Once the design conditions for room
relative humidity have been determined the supply air flow
rate necessary to maintain this level can be calculated. The
required flow rate to meet the latent load can be determined
by the following equation on the next page:

APPLICATION GUIDE

.
V = the volumetric flow rate, CFM
.
q = latent heat gain in the space, BTU/H
HRr = room air humidity ratio, lbs water/lbs dry air
HRp = primary air humidity ratio, lbs water/lbs dry air
It follows that the required flow rate to maintain control of
the humidity will rapidly increase as the difference between
the room air and primary air humidity ratios decrease. As a
result, designs seeking to maintain relatively low humidity
ratios will need a high primary flow rate if the dew point
temperature of the supply air is close to the design dew
point in the room.
Comparing the required supply airflow rates for ventilation
and to maintain the relative humidity of the space, the
higher of the two flow rates will determine the minimum
flow rate allowable for the space. If necessary the supply
air flow rate can be increased to supplement the sensible
cooling of the products selected.
After the IAQ requirements have been tentatively set, the
required equipment capacities to meet the heat loads and
losses can are determined. Care should be taken to design
around actual loads/losses that will be experienced in the
space. Overdesigning the system will increase installation
and equipment costs, and could potentially cause thermal
comfort issues. Once the capacity requirements have been
calculated, either supply air conditions or building design/
construction (if possible) can be adjusted to be more suited
to chilled ceiling application.

PRODUCT SELECTION

The type of product to be used to is at the designers


discretion. However the recommended limitations of
maximum capacity per square foot should not be exceeded
where high levels of thermal comfort are required.

There are several ways to operate these products to prevent


condensation. The primary step to preventing condensation
is for the chilled water design supply temperature to be at
least 1BF above the dew-point temperature of the space.
Also, the supply air to the space must also be sufficiently
dehumidified to maintain the design relative humidity
conditions. The secondary measures are noted below:

At this time the supply air temperature should be tentatively


selected. Supply air temperature can be varied between
cooling and heating, but most designs keep a fixed
temperature as long as heating requirements can be met.
The size and configuration of products selected should be
completed while adjusting the following parameters:
Water flow rate: this should be selected to minimize
pressure drop, should be no higher 10 ft w.g., while
maintaining turbulent flow through the product.
Supply airflow rate: flow rate must be maintained
above the minimum determined for IAQ requirements,
but can be increased to offset the sensible
cooling requirements of the product selected
"" Increasing the flow rate in active beams while
maintaining the same nozzle geometry will
result in an increase of operating pressure. The
recommended operating range is typically between
0.2 in w.g. and 0.8 in w.g. Operating pressure in
active beams will also directly impact the noise
generated by the product during operation.
Unit placement/Configurations:
"" Radiant panels and sails: These products should
be installed so that no more than 75% of the
available ceiling space is made up of active panels/
sails. Panels models with perforated faces and
backed with acoustic fleece insulation can be used
to improve noise attenuation within the space.
"" Passive Beams: Passive beams should not be
installed directly above occupants since the
highest velocities occurring from the convection
process will occur directly underneath the beam.
"" It is critical to the operation of passive beams
that adequate space is provided for air flow
through the beam. When installed in a flush mount
application, shadow gaps, perforated ceiling
tiles, dummy beams, or return air grilles must
be installed so that warm room air enter the air
path for the passive beams. It is recommended
that the total free area for the return air path be
at least 50% of the passive beam surface area.
In exposed applications, the beams should be
installed with a minimum distance between the
top surface of the beam and the ceiling that is
equivalent to half of the beam width, see Figure 7.

APPLICATION GUIGE

Once product type has been decided the entering water


temperature should be selected such that condensation
is prevented. The majority of chilled ceiling products do
not include a means to collect or manage condensation.
This means the temperature of the heat transfer surface,
either water coil or panel/sail surface, must be higher
than the dew-point temperature of the space to prevent
the formation of condensation. However, to achieve the
maximum cooling capacity the entering water temperature
should be as low as possible. This can be difficult when
trying to get the most capacity out of chilled ceiling
products.

Properly insulated valves and piping


Measures used to shut off chilled water flow
"" Condensation sensors installed
on the supply water piping
"" Relative humidity/dew-point temperature
sensor installed in the return air path
Raising the chilled water supply temperature
"" Using a relative humidity sensor in conjunction with
a room temperature system to determine moisture
content and dew-point temperature of the space.
Using this information the chilled water temperature
can be adjusted upward to prevent condensation.
This measure should only be used in the event
that an entire building is at risk for condensation.

www.titus-hvac.com | www.titus-energysolutions.com

.
.
V = q ./. [4840 x (HRr - HRp)]

Chilled Beam

U13

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE

Figure 6a. Condensation Prevention Strategies


Thermostat/Room Controller

2-Way Flow Control Valves


(On/Off or Proportional Control)

Balancing Valves
(Manual or Automatic)

Condesate Sensors

Chilled Beams

A) Condensate sensors installed on the chilled water supply shut


down individual flow control valves when condesnation is detected.

Thermostat/Room Controller
Balancing Valves
(Manual or Automatic)

2-Way Flow Control Valves


(On/Off or Proportional Control)

Figure 6b. Condensation Prevention Strategies

Relative Humidity
Sensor

Chilled Beams

B) Relative humidity sensor installed in return air path to shut down


zone flow control valve when relative humidty reaches set point of
the sensor.

3-Way Flow Control Valve


(Proportional Control)

APPLICATION GUIDE

Variable speed pump

Balancing Valves
(Manual or Automatic)

Thermostat/
Room Controller
w/ Dew-point Sensor

Chilled Beams

U14

C) Use of a 3-way proportional valve and variable speed pump to raise


supply water temperature above the room dew-point temperature.

Figure 6c. Condensation Prevention Strategies

Chilled Beam

APPLICATION GUIDE

X/2

Passive beams should be mounted such that the return air path
is not restricted.

Figure 7. Passive beam mounting height


"" Active Beams: With the different configurations
available in active beams, 1, 2, and 4-way beams
a design can be implemented to effectively create
a comfortable space. In open office spaces as
well as internal offices 2-way or 4-way beams are
typically used. The flexibility provided by 2-way
and 4-way beams, due to multiple sizes and nozzle
configurations, allow them to be appropriately
applied in most applications. 1-way beams are
typically used in perimeter zones and small spaces
such as individual offices and hotel rooms.

a)

www.titus-hvac.com | www.titus-energysolutions.com

"" After the throw pattern has been decided,


placement of the beam within the space can be
determined. Active chilled beams, because of their
design, share throw characteristics with conventional
slot diffusers. Placement and orientation of active
beams is critical for thermal comfort due long
throw values associated with active beams. In
open office plans it is typically more cost effective
to use several longer beams that are installed
parallel to the long direction of conventional ceiling
systems, instead of numerous smaller beams the
length of the module division. (Figure 8, Openoffice Active Beam Layout) However in an open
office the number and size of beams used will be
determined by balancing the cost per beam, cost of
air side operating pressure, and water side pumping
power to achieve optimum energy efficiency.
"" When applying 2-way and 4-way beams in small
offices and individual offices the recommended
location is directly above the occupants. This will
result in the lowest velocities within the occupied
space. It is also recommended that 2-way beams
are installed lengthwise in the space. This will
allow for the use of longer beams, reducing the
cooling requirements per linear foot which will inturn lower total air flow per foot and the resulting
velocities in the space ensuring occupancy comfort.
If placement is required near a wall use of 1-way
throw beams are recommended. 1-way beams
can also be effectively used in perimeter zones
for cooling applications; however they should be
supplemented with baseboard heating to address
window loads during the heating season. 2-way
beams can be effectively applied in perimeter
zones for both heating and cooling. Care must
be taken if 2-way beams are installed parallel to
windows. In intermediate seasons when internal
cooling is required and window surfaces are
cool an acceleration of the air can occur in the
space creating drafts and potential discomfort.

b)

APPLICATION GUIGE

Figure 8 - Open-office Active Beam Layout: In lengthwise installations(a) there are less piping and duct
connections than in crosswise installations(b). In crosswise installations, there is typically one beam per
module. Even if the total cost for the beams in both layouts are the same, installation costs, additional
valves, piping, and ductwork will prove to be more costly.

U15

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

APPLICATION GUIDE

APPLICATION GUIDE

U16

Vcollision

Occupied Zone

The minimum distance between units (2X) or minimum distance from a sidewall (X), can
be determined by taking the difference between the diffuser's characteristic throw to 50
fpm (T50 ) and the distance between the ceiling and the occupied zone (Y).
Figure 9. Local Velocity Diagram
"" The ideal location for most active beams is directly
above the occupant. This is because the lowest
velocities in the space will occur in the induced air
path. If it is desired to position an active beam close
to a wall, a unit with an asymmetrical or 1-way
throw pattern is recommended. As active chilled
beams have throw characteristics similar to linear
slot diffusers the same principles for determining
thermal comfort conditions should be used. Location
for final placement should take into consideration
the allowable average air speed in the occupied
space in accordance with ASHRAE Standard 55.
Accounting for the air side sensible capacity will
allow for reduced capacity requirements of the
water coils in the beams. Designing with this in
mind will reduce airflow requirements per linear
foot, which will help to meet the requirements for
thermal comfort. When placing two beams in the
same space as shown in Figure 9, Local velocity
diagram, care must be taken to ensure that the
colliding air streams do not result in velocities over
50 fpm causing discomfort. A general guideline
to achieve air velocities of 50 fpm or less in the
occupied space is to ensure the velocities of
colliding airstreams are below 100 fpm. If velocities
at the point of collision are greater than 100 fpm,
the distance from the ceiling for the air flow to
slow to 50 fpm is noted in the equation below:
Y=T50 - X
Where:

Y = distance from the ceiling

X = half the distance to the adjacent diffuser

T50 = diffuser characteristic throw to 50 fpm

CONTROL OF CHILLED CEILING SYSTEMS

Very basic room controls can be used with chilled ceiling


systems. This is due to the fact that most systems are
designed to operate with a constant volume of supply
air. Also, the large coil size, combined with relatively low
velocities across the coils result in a fairly long response
time.
With chilled beams or radiant systems, the most common
method for controlling room temperature is regulating
the water flow rate through the selected equipment. The
alternative is to vary the supply water temperature.
The control of water flow rate is achieved through onoff, time proportional on-off, or modulating control valve
actuators. The maximum flow rate should be limited by
a balancing valve installed on each beam circuit. It is
generally recommended for 2-way valves to be used to
reduce pumping costs, but 3-way valves can be used when
pump speeds are not variable. While on-off and modulating
actuator control is straight forward, time proportional
on-off systems are a bit more complex. These systems
use a feedback control loop to open and close an on-off
actuator such that the total time open is proportional to the
percentage of flow that is requested by a modulated room
controller. While control of this system is more complex,
actuator first costs are greatly reduced.
Chilled beams should be connected in parallel so that each
beam sees the same entering water temperature. For the
greatest flexibility of control each beam should be fitted with
an actuated control valve. With this setup, the flow rate can
be modulated in each beam. And, in the event the entering
water temperature reaches a point where condensation is a
concern the flow rate to individual units affected can be shut

Chilled Beam

APPLICATION GUIDE

handler loop and chilled beam loop are acceptable (see


Figure 11b).
Supply Water
Temperature Control

Chilled Beam
Supply Loop

Balancing Valves
(Manual or
Automatic)

Chilled Beam
Supply Loop

Main Return
Loop

Supply Water
Temperature Control

Chiller Bypass Loop

3-Way Flow Control Vale


(Proportional Control)

Chilled Beams
A) Beams installed with a single 2-way valve serving a entire zone.

3-Way Flow Control Vale


(Proportional Control)
Chilled Beam
Return Loop

Figure 10a. Chilled beam zone control - Single flow control

Thermostat

3-Way Flow
Control Vale
(On/Off or
Proportional
Control)

Heat Exchanger
Bypass Loop

A) Supply temperature control with


dedicated chiller

Main Supply
Loop

www.titus-hvac.com | www.titus-energysolutions.com

2-Way Flow Control Vale (On/Off


or Proportional Control)

Chilled Beam
Return Loop

B) Supply temperature control


secondary chilled beam loop

Figure 11a. Supply water temperature control


with dedicated chiller; Figure 11b. Supply water
temperature control chilled beam loop

When designing systems with occupied/unoccupied modes


or with night set back set ups. It is critical to ensure the
design relative humidity conditions are met prior any water
based sensible cooling. In most cases, 30 minutes of dryair ventilation will be enough to prevent any condensation
during morning start-up and when returning to occupied
modes. This can easily be achieved for night set back/
morning start up by offsetting the time schedules for the air
handlers and chilled beam system pumps.

Balancing Valves
(Manual or
Automatic)

Chilled Beams
B) Beams installed with a single 3-way valve serving a entire zone.

Figure 10b. Chilled beam zone control

Alternatively to varying water flow rate through the beam,


the entering water temperature can be varied according
to the load in the space. This requires more sophisticated
control sequences. Varying the water temperature also
requires a bypass loop, that can inject higher temperature
water from the return loop of the chilled beams or main air
handler into the supply water loop for the beams.
In order to control the supply water temperature a
dedicated chiller and supply/return circuits can be used
(see Figure 11a), or heat exchanger between the main air

APPLICATION GUIGE

down, so that the entire zone do not suffer a loss in sensible


capacity. The alternative is one actuated control valve per
zone. In either situation, each beam should be fitted with
isolation valves on the both the supply and return.

U17

DISA is a linear active chilled beam diffuser with 2-way


air distribution (1-way available on DISA-300HT only).
Unique linear design provides high
induction and low noise levels.

DISA

www.titus-hvac.com | www.titus-energysolutions.com

Chilled Beam

Linear Active Chilled Beams


DISA

Available in cooling & supply air (CO) or cooling,


heating & supply air (CH) configurations.
Available as diffuser shell (no coil/piping).
Accessories include rubber lip seal.

Standard finish is RAL 9010 white


paint on diffuser face.
Diffuser is designed to fit into standard
module ceiling grids 24 or 12 in width.

DESCRIPTION

The DISA active chilled beam diffuser was developed for


removing high thermal loads from the space. Supplied with
tempered and dehumidified primary air, to handle the latent
load, the beam addresses the remaining loads in the space
with a heat exchanger installed in the unit. Decoupling the
latent and sensible loads takes advantage of the superior
volumetric heat capacity of water. The reduced the volume
of air that must be delivered to the space results in reducing
air handler capacity and size, smaller duct sizes, and overall
energy savings.
In the primary distribution channel, CNC formed nozzles are
precisely arranged. The number and size of nozzles (A, B, C,
D) can be varied, thus allowing optimum adjustment of the
primary supply air volume. By reducing the primary air to
meet the minimum requirements for either room ventilation
or latent load in the space, whichever is greater, total
system energy costs are reduced.

DISA

The primary air, supplied by the air distribution system is


supplied to the mixing chamber via induction nozzles. In
the mixing chamber, room air is induced over a horizontally
mounted heat exchanger, to address sensible loads in the
space. The primary air is mixed with the cooled secondary
air and supplied to the room through 1- or 2-slot diffusers
integrated into the unit design.
The DISA chilled beams are available in a multitude of
configurations, resulting in produces that easily integrate
into any building or design. These products have been
designed to address heating and cooling loads in the space,
with either a 2-pipe or 4-pipe system. The low overall height
of the DISA product line is ideal for reducing the space
required for false ceilings in new buildings and for retrofit
applications.

INSTALLATION

U18

In order to achieve a uniform cooling capacity, the beams


should be connected to the cold water distribution system

in parallel. It is recommended that DISA chilled beams are


connected to a supply air duct system which controls the
supplied primary air volume. When integrated with room
controllers, the units can be used both for single room and
zone control.

ADVANTAGES
Removal of high thermal loads is
possible in this air/water system.
The height of the air duct system is reduced to a
minimum, due to the low supply of primary air.
Substantial reduction in the operating
costs, due to low primary air volume.
Improvement of the thermal comfort inside the room.
Individual adjustment of the primary air volume
by means of the nozzle configuration A, B, C, D.
Suitable for all standard ceiling grids.

CLEANING OF THE GRILLE/COIL


To clean the grill and the coil, release the safety lock
attached to the profile (see #1, above). The grille can now
Titus by Schako

Chilled Beam

Linear Active Chilled Beams (continued)

(1-Way)

www.titus-hvac.com | www.titus-energysolutions.com

swing down, and both the grille and coil become easily
accessed for cleaning purposes (see #2, above). Do not
use any scouring agents for cleaning these components;
damage to the unit construction materials (galvanized steel,
aluminum and copper) and the surface coatings (paint
and anodized surfaces) may occur. After completion of
maintenance, grille must be returned to its original operating
position and then the safety locks must be engaged.
(2-Way)

Schematic diagram of the mode of operation


1
2
3
4

Primary Air
Room Air
Secondary Air
Heat exchanger

(1-Way)

(2-Way)

Schematic diagram of the jet path

DISA
U19
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

Linear Active Chilled Beams (continued)

CONSTRUCTION
HOUSING

Galvanized sheet steel, with 1 or 2 connection pipes


E4, E5 and E6, position of primary air inlet:
Vertical connection (-V, standard).
Horizontal connection (-H).
with 1 central connection piece (AS1, -AS4*).
with 2 central connection pieces at the
same distance (-AS2/AS3, -AS5/6*).
Suitable for all standard ceiling grids.

SLOT

Extruded aluminum profile painted to


RAL 9010 (white, standard).

PERFORATED SHEET GRILLE (-SR,-SQ,-RE,-OB)


Galvanized sheet steel painted to
RAL 9010 (white, standard).

LOUVRE GRID (-PA)

Extruded aluminum profile painted to


RAL 9010 (white, standard).

END PIECES (PAIR)

Sheet steel painted to RAL 9010 (white, standard).

HEAT EXCHANGER (4-CONDUCTOR COOLING AND


HEATING)

A E12mm, copper tubing (14 tubes for


cooling mode / 4 for heating mode).
Connection Cu, 12mm x 1.0mm (wall) smooth wall.
*Available on DISA-300HT, 1-way throw, horizontal duct
connection only

ACCESSORIES
EXTENSION

Possible from 0.5 to 10 inches. The total length and


the extension of the DISA must not exceed 10 feet.
Upon customer request, this component may
have an integrated return air plenum box or
one equipped with mechanically operated grille
for mounting various components (lighting,
loudspeaker, smoke detector, sprinkler, etc.).
Contact Titus for pricing and availability.

RUBBER LIP SEAL (-GD)

At the connection pipe for better tightness

CONTROL UNITS

Valves
Actuators
Temperature controls

CONDENSATION DETECTOR

DISA

Galvanized sheet steel frame.


Aluminum fins.

U20
Titus by Schako

DIMENSIONS

Chilled Beam
www.titus-hvac.com | www.titus-energysolutions.com

DISA 300HT - (1-WAY)

B = 11.7

ARRANGEMENT OF THE CONNECTION PIPES (-AS) AND WATER CONNECTION (-WS)

Number/position of the connection pipes


with vertical connection (-V standard).
with horizontal connection (-H).
with 1 central connection piece (AS1, -AS4).
with 2 central connection pieces
(-AS2/AS3, -AS5/6).

DIMENSIONS

Number/position of the water connections


with 4 water connections (2 for cooling
mode / 2 for heating mode).
sideways top left (-WS1).
sideways top right (-WS2).

U21
Titus by Schako

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS

Chilled Beam

DISA 300HT - (2-WAY)

ARRANGEMENT OF THE CONNECTION PIPES (-AS) AND WATER CONNECTION (-WS)

DIMENSIONS

Number/position of the connection pipes


with vertical connection (-V standard).
with horizontal connection (-H).
with 1 central connection piece (AS1, -AS4).
with 2 central connection pieces
(-AS2/AS3, -AS5/6).
Number/position of the water connections
with 4 water connections (2 for cooling
mode / 2 for heating mode).
sideways top left (-WS1).
sideways top right (-WS2).

U22
Titus by Schako

DIMENSIONS

Chilled Beam
www.titus-hvac.com | www.titus-energysolutions.com

DISA 600HT

ARRANGEMENT OF THE CONNECTION PIPES (-AS) AND WATER CONNECTION (-WS)

Number/position of the connection pipes


with vertical connection (-V standard).
with horizontal connection (-H).
with 1 central connection piece (AS1, -AS4).
with 2 central connection pieces
(-AS2/AS3, -AS5/6).

DIMENSIONS

Number/position of the water connections


with 4 water connections (2 for cooling
mode / 2 for heating mode).
sideways top left (-WS1).
sideways top right (-WS2).

U23
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS
DISA 300HT (1-WAY)

DISA 300HT (2-WAY)

DIMENSIONS

DISA 300HT WITH PERFORATED SHEET GRILLE

U24
Titus by Schako

DIMENSIONS

Chilled Beam
www.titus-hvac.com | www.titus-energysolutions.com

DISA 300HT WITH END PIECE

DISA 300HT WITHOUT END PIECE

DISA 300HT BAND DESIGN WITHOUT END PIECES MOUNTED IN-BETWEEN

DIMENSIONS

*DIMENSIONS ON REQUEST

U25
Titus by Schako

Chilled Beam

Vertical Connection (-V)

DISA 300HT - NUMBER OF CONNECTION PIECES


L - 7

with 1 connection piece (-AS1)


L - 7

Vertical Connection (-V)

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS

Horizontal Connection (-H)

with 2 connection piece (-AS2/AS3)


L - 7

ACCESSORIES
Rubber lip seal (-GD)

Horizontal Connection (-H)

DIMENSIONS

with 1 connection piece (-AS1)


L - 7

with 2 connection piece (-AS2/AS3)

U26
Titus by Schako

DIMENSIONS

Chilled Beam
www.titus-hvac.com | www.titus-energysolutions.com

DISA 600HT WITH END PIECE

DISA 600HT WITHOUT END PIECE

U
DISA 600HT BAND DESIGN WITHOUT END PIECES MOUNTED IN-BETWEEN

DIMENSIONS

DISA 600HT WITH PERFORATED SHEET GRILLE

U27
Titus by Schako

Chilled Beam

Vertical Connection (-V)

DISA 600HT - NUMBER OF CONNECTION PIECES

Vertical Connection (-V)

with 1 connection piece (-AS1)

with 2 connection piece (-AS2/AS3)

Horizontal Connection (-H)

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS

Horizontal Connection (-H)

with 1 connection piece (-AS1)

with 2 connection piece (-AS2/AS3)

ACCESSORIES

DIMENSIONS

Rubber lip seal (-GD)

U28
Titus by Schako

Chilled Beam

PERFORMANCE DATA

Nozzle
Type

[ft]
A

B
3
C

B
4
C

B
5
C

B
6
C

Cooling

Heating

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

0.2

6.15

133

341

474

321

0.5

9.75

212

549

761

495

0.8

12.50

266

693

959

573

0.2

10.60

229

566

795

525

0.5

16.95

362

788

1150

0.8

21.40

457

921

1378

0.2

19.71

423

788

1211

693

0.5

31.15

665

1109

1774

740

0.8

39.20

843

1293

2136

730

0.2

29.45

635

768

1402

737

0.5

46.62

1003

1211

2214

699

0.8

58.91

1262

1467

2730

618

2.14

659
0.13

706

0.2

9.32

198

498

696

478

0.5

14.62

314

778

1092

727

0.8

18.44

396

959

1355

839

0.2

15.89

338

798

1136

771

0.5

25.00

536

1075

1610

0.8

31.57

676

1228

1904

0.2

29.03

624

1075

1699

1007

2.68

959
0.17

0.5

45.98

989

1440

2429

1075

58.06

1245

1648

2893

1051

0.2

43.65

938

1058

1996

1071

0.5

69.08

1484

1563

3047

1003

0.8

87.30

1873

1842

3716

884

0.2

11.87

252

635

887

604

0.5

18.65

399

993

1392

938

0.8

23.52

505

1218

1723

1085

0.2

20.13

433

1020

1454

989

0.5

32.00

686

1372

2057

1245

0.8

40.26

863

1563

2426

0.2

37.08

795

1368

2163

1307

0.5

58.70

1259

1829

3088

1406

0.8

74.17

1590

2105

3695

1385

0.2

55.73

1198

1334

2532

1406

0.5

88.15

1890

1979

3869

1327

0.8

111.25

2388

2324

4712

1184

0.20

0.2

14.83

317

792

1109

761

23.31

502

1242

1744

1170

0.8

29.45

631

1522

2153

1355

0.2

25.22

543

1273

1815

1239

0.5

40.05

860

1696

2556

1549

0.8

50.43

1082

1924

3006

0.2

46.62

1000

1699

2699

1628

0.5

73.74

1580

2249

3828

1740

0.8

93.02

1993

2590

4582

1709

0.2

69.93

1501

1665

3166

1737

0.5

110.61

2375

2440

4814

1634

0.8

139.64

2996

2815

5811

1450

0.23

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

1338

0.5

3.65

COOLING:

1027

0.8

3.15

PERFORMANCE BASED ON:

PERFORMANCE DATA

Primary Air
Ps

www.titus-hvac.com | www.titus-energysolutions.com

DISA 300HT: 1-WAY THROW

1662

U29
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DISA 300HT: 1-WAY THROW (continued)


Type

[ft]
A

B
7
C

B
8
C

B
9

PERFORMANCE DATA

Primary Air

Cooling

Heating

Ps

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

0.2

17.38

372

928

1300

887

0.5

27.34

587

1454

2040

1378

0.8

34.54

740

1774

2515

1597

0.2

29.67

635

1494

2129

1460

0.5

46.83

1007

1979

2986

1836

0.8

59.12

1269

2238

3508

4.15

0.27

1972

0.2

54.67

1170

1979

3149

1928

0.5

86.46

1853

2614

4466

2074

0.8

108.92

2337

3057

5394

2044

0.2

82.01

1761

1931

3692

2068

0.5

129.68

2781

2846

5626

1958

0.8

163.59

3511

3265

6776

1747

0.2

19.92

427

1058

1484

1013

0.5

31.36

672

1662

2334

1590

0.8

39.63

850

2027

2876

1842

0.2

34.12

730

1716

2446

1679

0.5

53.82

1153

2262

3415

0.8

67.81

1457

2542

3999

4.69

62.72

1344

2259

3603

2231

98.96

2122

2941

5063

2409

0.8

125.02

2678

3446

6125

2378
2402

0.2

94.08

2016

2197

4214

0.5

148.75

3190

3190

6380

2283

0.8

187.74

4026

3692

7718

2044

0.2

22.67

485

1204

1689

1157

0.5

35.81

768

1897

2665

1808

0.8

45.13

969

2303

3272

2098

0.2

38.78

833

1952

2784

1914

0.5

61.24

1314

0.8

77.34

1658

2552

3866
4504

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

2279

0.2

2846

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

2119
0.30

0.5

5.19

COOLING:

2416
0.34

2597

0.2

71.41

1532

2552

4084

2542

0.5

112.73

2419

3289

5708

2740

0.8

142.40

3361

3917

7278

2706

0.2

107.22

2300

2487

4787

2733

0.5

169.52

3634

3596

7230

2597

0.8
A

B
10
C

U30

PERFORMANCE BASED ON:

Nozzle
L

0.2

25.43

546

1344

1890

1297

0.5

40.05

860

2095

2955

2030

0.8

50.64

1085

2484

3569

2354

0.2

43.44

935

2153

3088

2146

0.5

68.87

1474

2706

4180

2713

0.8

86.88

1863

2982

4845

5.66

0.37

2914

0.2

80.10

1720

2706

4425

2849

0.5

126.72

2716

3613

6329

3074

0.8

159.77

3429

4371

7800

3033

0.2

120.36

2579

2648

5227

3064

0.5

190.29

4081

4094

8175

2914

0.8

Titus by Schako

Chilled Beam

PERFORMANCE DATA

Nozzle
Type

[ft]
A

B
3
C

B
4
C

B
5
C

B
6
C

Cooling

Heating

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

0.2

6.15

133

392

525

375

0.5

9.75

212

624

836

549

0.8

12.50

266

778

1044

628

0.2

10.60

229

641

870

577

0.5

16.95

362

887

1249

0.8

21.40

457

1030

1488

0.2

19.71

423

894

1317

744

0.5

31.15

665

1232

1897

795

0.8

39.20

843

1423

2266

781

0.2

29.45

635

887

1522

792

0.5

46.62

1003

1351

2354

751

0.8

58.91

1262

1617

2880

672

2.14

713
0.13

757

0.2

9.32

198

566

764

556

0.5

14.62

314

873

1187

805

0.8

18.44

396

1065

1460

914

0.2

15.89

338

894

1232

850

0.5

25.00

536

0.8

31.57

676

0.2

29.03

624

2.68

1191

1726

1351

2027

1037

1198

1822

1085

0.17

0.5

45.98

989

1580

2569

1153

58.06

1245

1795

3040

1129

0.2

43.65

938

1194

2133

1150

0.5

69.08

1484

1723

3207

1082

0.8

87.30

1873

1894

3767

962

0.2

11.87

252

720

972

706

0.5

18.65

399

1109

1508

1041

0.8

23.52

505

1351

1856

1187

0.2

20.13

433

1143

1576

1092

0.5

32.00

686

1515

2201

0.8

40.26

863

1720

2583

0.2

37.08

795

1518

2313

1409

0.5

58.70

1259

2013

3272

1508

0.8

74.17

1590

2286

3876

1488

0.2

55.73

1198

1505

2702

1508

0.5

88.15

1890

2191

4081

1430

0.8

111.25

2388

2201

4589

1283

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

1348
0.20

1440

0.2

14.83

317

901

1218

914

0.5

23.31

502

1389

1890

1297

0.8

29.45

631

1679

2310

1481

0.2

25.22

543

1423

1965

1361

0.5

40.05

860

1866

2726

1675

0.8

50.43

1082

2109

3190

0.2

46.62

1000

1880

2880

1754

0.5

73.74

1580

2477

4057

1866

0.8

93.02

1993

2798

4790

1836

0.2

69.93

1501

1870

3371

1863

0.5

110.61

2375

2702

5077

1761

0.8

139.64

2996

2266

5261

1576

3.65

COOLING:

1105

0.8

3.15

PERFORMANCE BASED ON:

0.23

PERFORMANCE DATA

Primary Air
Ps

www.titus-hvac.com | www.titus-energysolutions.com

DISA 300HT: 2-WAY THROW

1788

U31
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DISA 300HT: 2-WAY THROW (continued)


Type

[ft]
A

B
7
C

B
8
C

B
9

PERFORMANCE DATA

Primary Air

Cooling

Heating

Ps

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

0.2

17.38

372

1058

1430

1037

0.5

27.34

587

1624

2211

1529

0.8

34.54

740

1955

2695

1747

0.2

29.67

635

1668

2303

1610

0.5

46.83

1007

2173

3180

1986

0.8

59.12

1269

2450

3719

4.15

0.27

2122

0.2

54.67

1170

2180

3351

2078

0.5

86.46

1853

2907

4760

2225

0.8

108.92

2337

3286

5623

2194

0.2

82.01

1750

2160

3910

2218

0.5

129.68

2781

3187

5968

2109

0.8

163.59

3511

1976

5486

1897

0.2

19.92

427

1208

1634

1187

0.5

31.36

672

1856

2528

1764

0.8

39.63

850

2228

3078

2016

0.2

34.12

730

1914

2644

1853

0.5

53.82

1153

2474

3627

0.8

67.81

1457

2767

4224

4.69

62.72

1344

2477

3821

2405

98.96

2122

3269

5391

2583

0.8

125.02

2678

3719

6398

2552
2576

0.2

94.08

2016

2450

4466

0.5

148.75

3190

3589

6780

2457

0.8

187.74

4026

2119

6145

2218

0.2

22.67

485

1375

1860

1355

0.5

35.81

768

2115

2883

2006

0.8

45.13

969

2518

3487

2296

0.2

38.78

833

2173

3006

2112

0.5

61.24

1314

0.8

77.34

1658

2774

4088
4746

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

2453

0.2

3088

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

2296
0.30

0.5

5.19

COOLING:

2614
0.34

2794

0.2

71.41

1532

2781

4313

2740

0.5

112.73

2419

3695

6114

2941

0.8

142.40

3054

4204

7257

2904

0.2

107.22

2300

2753

5053

2931

0.5

169.52

3634

4098

7732

2798

0.8
A

B
10
C

U32

PERFORMANCE BASED ON:

Nozzle
L

0.2

25.43

546

1535

2081

1522

0.5

40.05

860

2310

3170

2252

0.8

50.64

1085

2675

3760

2576

0.2

43.44

935

2368

3303

2368

0.5

68.87

1474

2907

4381

2934

0.8

86.88

1863

3293

5156

5.66

0.37

3136

0.2

80.10

1720

2914

4633

3071

0.5

126.72

2716

4221

6937

3296

0.8

159.77

3429

2713

6142

3258

0.2

120.36

2579

2887

5466

3289

0.5

190.29

4081

4197

8278

3139

0.8

Titus by Schako

Chilled Beam

PERFORMANCE DATA

Nozzle
Type

[ft]
A

B
3
C

B
4
C

B
5
C

B
6
C

Cooling

Heating

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

0.2

6.15

133

392

525

375

0.5

9.75

212

624

836

549

0.8

12.50

266

778

1044

628

0.2

10.60

229

641

870

577

0.5

16.95

362

887

1249

0.8

21.40

457

1030

1488

0.2

19.71

423

894

1317

744

0.5

31.15

665

1232

1897

795

0.8

39.20

843

1423

2266

781

0.2

29.45

635

887

1522

792

0.5

46.62

1003

1351

2354

751

0.8

58.91

1262

1617

2880

672

2.14

713
0.13

757

0.2

9.32

198

566

764

556

0.5

14.62

314

873

1187

805

0.8

18.44

396

1065

1460

914

0.2

15.89

338

894

1232

850

0.5

25.00

536

0.8

31.57

676

0.2

29.03

624

2.68

1191

1726

1351

2027

1037

1198

1822

1085

0.17

0.5

45.98

989

1580

2569

1153

58.06

1245

1795

3040

1129

0.2

43.65

938

1194

2133

1150

0.5

69.08

1484

1723

3207

1082

0.8

87.30

1873

1894

3767

962

0.2

11.87

252

720

972

706

0.5

18.65

399

1109

1508

1041

0.8

23.52

505

1351

1856

1187

0.2

20.13

433

1143

1576

1092

0.5

32.00

686

1515

2201

0.8

40.26

863

1720

2583

0.2

37.08

795

1518

2313

1409

0.5

58.70

1259

2013

3272

1508

0.8

74.17

1590

2286

3876

1488

0.2

55.73

1198

1505

2702

1508

0.5

88.15

1890

2191

4081

1430

0.8

111.25

2388

2201

4589

1283

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

1348
0.20

1440

0.2

14.83

317

901

1218

914

0.5

23.31

502

1389

1890

1297

0.8

29.45

631

1679

2310

1481

0.2

25.22

543

1423

1965

1361

0.5

40.05

860

1866

2726

1675

0.8

50.43

1082

2109

3190

0.2

46.62

1000

1880

2880

1754

0.5

73.74

1580

2477

4057

1866

0.8

93.02

1993

2798

4790

1836

0.2

69.93

1501

1870

3371

1863

0.5

110.61

2375

2702

5077

1761

0.8

139.64

2996

2266

5261

1576

3.65

COOLING:

1105

0.8

3.15

PERFORMANCE BASED ON:

0.23

PERFORMANCE DATA

Primary Air
Ps

www.titus-hvac.com | www.titus-energysolutions.com

DISA 600HT: 2-WAY THROW

1788

U33
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DISA 600HT: 2-WAY THROW (continued)


Type

[ft]
A

B
7
C

B
8
C

B
9

PERFORMANCE DATA

Primary Air

Cooling

Heating

Ps

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

0.2

17

317

1239

1556

1928

0.5

27

587

2143

2730

3293

0.8

35

740

2562

3303

3835

0.2

30

543

1839

2382

2764

0.5

47

1007

2781

3787

4013

0.8

59

1269

3204

4473

8.48

0.54

4453

0.2

55

1000

2706

3705

3798

0.5

86

1853

3610

5463

4685

0.8

109

2337

4009

6346

4924

0.2

82

1501

2842

4343

3569

0.5

130

2781

3852

6633

4357

0.8

164

3511

4326

7837

4480

0.2

20

372

1436

1808

2177

0.5

31

672

2450

3122

3702

0.8

40

850

2873

3722

4285

0.2

34

635

2102

2736

3088

0.5

54

1153

3166

4320

0.8

68

1457

3617

5074

9.48

63

1170

3057

4227

4217

99

2122

4077

6200

5145

0.8

125

2678

4528

7206

5370

0.2

94

1761

3221

4982

3937

0.5

149

3190

4337

7527

4736

0.8

188

4026

4831

8858

4825

0.2

23

427

1583

2010

2443

0.5

36

768

2723

3490

4105

0.8

45

969

3235

4204

4719

0.2

39

730

2388

3119

3436

61

1314

77

1658

3528

4842

4006

5664

0.2

71

1344

3473

4818

0.5

4637

113

2419

4531

6950

5575

0.8

142

3054

5005

8059

5777

0.2

107

2016

3596

5613

4296

0.5

170

3634

4821

8455

5077

0.2

25

485

1767

2252

2699

0.5

40

860

3016

3876

4473

0.8

51

1085

3555

4640

5111

10.49

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

4920

0.2

0.5

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

4456
0.60

0.5

0.8

COOLING:

4896
0.67

5370

0.8
A

B
10
C

U34

PERFORMANCE BASED ON:

Nozzle
L

0.2

43

935

2644

3579

3774

0.5

69

1474

3879

5353

5309

0.8

87

1863

4401

6264

11.46

0.74

5787

0.2

80

1720

3784

5504

5012

0.5

127

2716

4937

7653

5947

0.8

160

3429

5442

8871

6114

0.2

120

2579

3999

6578

4623

0.5

190

4081

5268

9349

5374

0.8

Titus by Schako

Chilled Beam

Linear Active Chilled Beams (continued)

DISA-V is a linear sidewall active chilled beam


diffuser with horizontal air distribution.
DISA-V

Unique linear design provides high


induction and low noise levels.
Configurable as cooling & supply air (CO) or cooling,
heating & supply air (CH) configurations.
Available as diffuser shell (no coil/piping).
Accessories include rubber lip seal.

Standard finish is RAL 9010 white


paint on diffuser face.
Diffuser is designed to be recessed into
a sidewall, soffit or bulkhead.

DESCRIPTION

INSTALLATION

The DISA-V sidewall active chilled beam diffuser was


developed for removing high thermal loads from the space.
Supplied with tempered and dehumidified primary air, to
handle the latent load, the beam addresses the remaining
loads in the space with a heat exchanger installed in
the unit. Decoupling the latent and sensible loads takes
advantage of the superior volumetric heat capacity of water.
The reduced the volume of air that must be delivered to
the space results in reducing air handler capacity and size,
smaller duct sizes, and overall energy savings.

In order to achieve a uniform cooling capacity, the beams


should be connected to the cold water distribution system in
parallel. It is recommended that DISA-V chilled beams are
connected to the supply air duct system which controls the
supplied primary air volume. When integrated with room
controllers, the units can be used both for single room and
zone control.

In the primary distribution channel, CNC formed nozzles are


precisely arranged. The number and size of nozzles (A, B, C,
D) can be varied, thus allowing optimum adjustment of the
primary supply air volume. By reducing the primary air to
meet the minimum requirements for either room ventilation
or latent load in the space, total system energy costs are
reduced.
The primary air, supplied by the air distribution system is
supplied to the mixing chamber via induction nozzles. In
the mixing chamber, room air is induced through a vertically
mounted heat exchanger, to address sensible loads in the
space. The primary air is mixed with the cooled secondary
air and supplied to the room in a horizontal throw pattern
through 1-slot diffuser integrated into the unit design.

www.titus-hvac.com | www.titus-energysolutions.com

DISA-V

ADVANTAGES
Removal of high thermal loads is
possible in this air/water system.
The size of the supply duct system is minimized
due to reduced primary air requirements.
Substantial reduction in the operating
costs due to low primary air volume.
Improved thermal comfort inside the space.
Individual adjustment of the primary air volume by
means of the nozzle configuration A, B, C, & D.
Suitable for all standard ceiling grids.

DISA-V

The DISA-V chilled beams are available in a multitude of


configurations, resulting in produces that easily integrate
into any building or design. These products have been
designed to address heating and cooling loads in the space,
with either a 2-pipe or 4-pipe system. The construction of
the DISA-V product line is ideal for installation in soffits
and sidewalls where ceiling space is limited. The horizontal
throw pattern is enables comfortable cooling to be delivered
to small spaces by effectively rolling without creating drafts.

U35
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

Linear Active Chilled Beams (continued)

Schematic diagram of the mode of operation

(1-Way)

(2-Way)

Schematic diagram of the jet path

CONSTRUCTION
HOUSING

Galvanized sheet steel, with 1 or 2 connection pipes


E4, E5 and E6, position of primary air inlet:
with 1 central connection piece (AS1, -AS4*).
with 2 central connection pieces at
the same distance (-AS2/AS3).

SLOT

Extruded aluminum profile painted to


RAL 9010 (white, standard).

DISA-V

PERFORATED SHEET GRILLE (-SR,-SQ,-RE,-OB)


Galvanized sheet steel painted to
RAL 9010 (white, standard).

LOUVRE GRID (-PA)

Extruded aluminum profile painted to


RAL 9010 (white, standard).

A E12mm, copper tubing (14 tubes for


cooling mode / 4 for heating mode).
Connection Cu, 12mm x 1.0mm (wall) smooth wall.

ACCESSORIES
EXTENSION

Possible up to 12 inches. The total length and the


extension of the DISA-V must not exceed 10 feet.

RUBBER LIP SEAL (-GD)

At the connection pipe for better tightness

CONTROL OPTIONS

Valves
Actuators
Temperature controls
Condensation sensor

HEAT EXCHANGER (4-PIPE COOLING AND HEATING)

U36

Galvanized sheet steel frame.


Aluminum fins.

Titus by Schako

Chilled Beam

DIMENSIONS

www.titus-hvac.com | www.titus-energysolutions.com

DISA-V

ARRANGEMENT OF THE CONNECTION PIPES (-AS) AND WATER CONNECTION (-WS)


WATER CONNECTIONS

DUCT CONNECTIONS WITH 1 CONNECTION PIECE (-AS1)


Number/position of the connection pipes
with 1 central connection piece (AS1).
with 2 central connection pieces (-AS2/AS3).
Number/position of the water connections
with 4 water connections (2 for cooling
mode / 2 for heating mode).
sideways top left (-WS1).
sideways top right (-WS2).

DIMENSIONS

WITH 2 CONNECTION PIECES (-AS2/-AS3)

U37
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS
WATER CONNECTIONS

Single
Connection

Dual
Connection

a,c

a,b

900
1200
1500

1800
2100
2400
2700
3000

PERFORATED SHEET GRILLE

ACCESSORIES

DIMENSIONS

Rubber lip seal (-GD)

U38
Titus by Schako

Chilled Beam

PERFORMANCE DATA

Nozzle
Type

[ft]
A

B
3
C

B
4
C

B
5
C

B
6
C

Cooling

Heating

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

0.2

6.15

133

341

474

321

0.5

9.75

212

549

761

495

0.8

12.50

266

693

959

573

0.2

10.60

229

566

795

525

0.5

16.95

362

788

1150

0.8

21.40

457

921

1378

0.2

19.71

423

788

1211

693

0.5

31.15

665

1109

1774

740

0.8

39.20

843

1293

2136

730

0.2

29.45

635

768

1402

737

0.5

46.62

1003

1211

2214

699

0.8

58.91

1262

1467

2730

618

2.14

659
0.13

706

0.2

9.32

198

498

696

478

0.5

14.62

314

778

1092

727

0.8

18.44

396

959

1355

839

0.2

15.89

338

798

1136

771

0.5

25.00

536

1075

1610

0.8

31.57

676

1228

1904

0.2

29.03

624

1075

1699

1007

2.68

959
0.17

0.5

45.98

989

1440

2429

1075

58.06

1245

1648

2893

1051

0.2

43.65

938

1058

1996

1071

0.5

69.08

1484

1563

3047

1003

0.8

87.30

1873

1842

3716

884

0.2

11.87

252

635

887

604

0.5

18.65

399

993

1392

938

0.8

23.52

505

1218

1723

1085

0.2

20.13

433

1020

1454

989

0.5

32.00

686

1372

2057

1245

0.8

40.26

863

1563

2426

0.2

37.08

795

1368

2163

1307

0.5

58.70

1259

1829

3088

1406

0.8

74.17

1590

2105

3695

1385

0.2

55.73

1198

1334

2532

1406

0.5

88.15

1890

1979

3869

1327

0.8

111.25

2388

2324

4712

1184

0.20

0.2

14.83

317

792

1109

761

23.31

502

1242

1744

1170

0.8

29.45

631

1522

2153

1355

0.2

25.22

543

1273

1815

1239

0.5

40.05

860

1696

2556

1549

0.8

50.43

1082

1924

3006

0.2

46.62

1000

1699

2699

1628

0.5

73.74

1580

2249

3828

1740

0.8

93.02

1993

2590

4582

1709

0.2

69.93

1501

1665

3166

1737

0.5

110.61

2375

2440

4814

1634

0.8

139.64

2996

2815

5811

1450

0.23

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

1338

0.5

3.65

COOLING:

1027

0.8

3.15

PERFORMANCE BASED ON:

PERFORMANCE DATA

Primary Air
Ps

www.titus-hvac.com | www.titus-energysolutions.com

DISA-V

1662

U39
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

DISA-V (continued)
Type

[ft]
A

B
7
C

B
8
C

B
9

PERFORMANCE DATA

Primary Air

Cooling

Heating

Ps

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

0.2

17.38

372

928

1300

887

0.5

27.34

587

1454

2040

1378

0.8

34.54

740

1774

2515

1597

0.2

29.67

635

1494

2129

1460

0.5

46.83

1007

1979

2986

1836

0.8

59.12

1269

2238

3508

4.15

0.27

1972

0.2

54.67

1170

1979

3149

1928

0.5

86.46

1853

2614

4466

2074

0.8

108.92

2337

3057

5394

2044

0.2

82.01

1761

1931

3692

2068

0.5

129.68

2781

2846

5626

1958

0.8

163.59

3511

3265

6776

1747

0.2

19.92

427

1058

1484

1013

0.5

31.36

672

1662

2334

1590

0.8

39.63

850

2027

2876

1842

0.2

34.12

730

1716

2446

1679

0.5

53.82

1153

2262

3415

0.8

67.81

1457

2542

3999

4.69

62.72

1344

2259

3603

2231

98.96

2122

2941

5063

2409

0.8

125.02

2678

3446

6125

2378
2402

0.2

94.08

2016

2197

4214

0.5

148.75

3190

3190

6380

2283

0.8

187.74

4026

3692

7718

2044

0.2

22.67

485

1204

1689

1157

0.5

35.81

768

1897

2665

1808

0.8

45.13

969

2303

3272

2098

0.2

38.78

833

1952

2784

1914

0.5

61.24

1314

0.8

77.34

1658

2552

3866
4504

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

2279

0.2

2846

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

2119
0.30

0.5

5.19

COOLING:

2416
0.34

2597

0.2

71.41

1532

2552

4084

2542

0.5

112.73

2419

3289

5708

2740

0.8

142.40

3361

3917

7278

2706

0.2

107.22

2300

2487

4787

2733

0.5

169.52

3634

3596

7230

2597

0.8
A

B
10
C

U40

PERFORMANCE BASED ON:

Nozzle
L

0.2

25.43

546

1344

1890

1297

0.5

40.05

860

2095

2955

2030

0.8

50.64

1085

2484

3569

2354

0.2

43.44

935

2153

3088

2146

0.5

68.87

1474

2706

4180

2713

0.8

86.88

1863

2982

4845

5.66

0.37

2914

0.2

80.10

1720

2706

4425

2849

0.5

126.72

2716

3613

6329

3074

0.8

159.77

3429

4371

7800

3033

0.2

120.36

2579

2648

5227

3064

0.5

190.29

4081

4094

8175

2914

0.8

Titus by Schako

Chilled Beam

PERFORMANCE DATA

Nozzle Type
L
[ft]

10

Connection Piece Diameter

Connection Piece Diameter

Connection Piece Diameter

Connection Piece Diameter

[in wg]

4"

5"

6"

4"

5"

6"

4"

5"

6"

4"

5"

6"

0.2
0.2
0.3
0.4
0.5
0.6
0.2
0.2
0.3
0.4
0.5
0.6
0.2
0.2
0.3
0.4
0.5
0.6
0.2
0.2
0.3
0.4
0.5
0.6
0.2
0.2
0.3
0.4
0.5
0.6
0.2
0.2
0.3
0.4
0.5
0.6
0.2
0.2
0.3
0.4
0.5
0.6
0.2
0.2
0.3
0.4
0.5
0.6

20
20
20
21
23
26
20
20
20
21
23
27
20
20
20
22
24
27
20
20
20
22
25
28
20
20
20
23
25
28
20
20
21
24
26
29
20
20
22
25
27
30
20
20
24
26
29
32

20
20
20
21
23
26
20
20
20
21
23
27
20
20
20
22
24
27
20
20
20
22
25
28
20
20
20
23
25
28
20
20
21
23
26
29
20
20
21
24
26
29
20
20
22
25
27
30

20
20
20
21
23
26
20
20
20
21
23
27
20
20
20
22
24
27
20
20
20
22
24
28
20
20
20
23
25
28
20
20
21
23
26
29
20
20
21
24
26
29
20
20
22
24
27
30

20
20
20
21
23
27
20
20
20
21
24
28
20
20
20
23
25
29
20
20
22
25
28
31
20
21
25
28
30
33
21
24
27
30
33
36
24
27
31
34
36
39
27
30
33
36
39
42

20
20
20
21
23
27
20
20
20
21
24
28
20
20
20
22
25
28
20
20
20
23
25
29
20
20
21
24
26
30
20
20
22
25
28
31
20
20
24
27
30
34
20
22
26
30
32
36

20
20
20
21
23
27
20
20
20
21
24
28
20
20
20
22
24
28
20
20
20
22
25
29
20
20
20
23
26
29
20
20
21
24
26
30
20
20
21
24
27
31
20
20
22
25
28
31

20
20
21
25
28
32
20
21
25
28
31
35
23
26
30
33
35
39
29
31
35
38
41
44
33
35
39
42
45
48
37
39
43
46
48
51
40
43
46
49
52
55
43
46
50
53
55
58

20
20
21
24
28
32
20
20
22
25
28
33
20
20
24
27
30
35
21
23
28
31
34
38
25
28
32
36
39
42
29
32
36
40
43
46
33
36
40
44
47
50
36
39
44
47
50
54

20
20
21
24
27
32
20
20
21
25
28
33
20
20
22
25
29
33
20
20
23
27
30
34
20
20
25
28
31
36
20
22
27
30
33
37
23
25
30
33
36
40
25
28
33
36
39
43

25
28
34
39
44
51
29
32
37
41
45
51
34
37
41
45
48
53
40
42
46
50
52
56
44
46
50
53
56
60
48
50
54
57
60
63
51
54
57
60
63
66
54
57
61
64
66
69

24
28
34
39
44
50
25
29
35
40
45
51
28
31
37
42
46
52
33
36
41
45
49
54
37
40
45
49
52
57
42
44
49
53
56
60
46
48
53
57
60
63
49
52
57
60
63
67

24
28
34
39
44
50
25
28
34
40
44
51
26
29
35
40
45
52
27
30
36
41
46
52
29
32
38
42
47
53
32
35
40
44
48
54
35
38
43
47
50
56
38
41
46
50
53
58

Titus by Schako

PERFORMANCE DATA

PS

www.titus-hvac.com | www.titus-energysolutions.com

DISA-V SOUND DATA (dBA)

U41

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

PART 1 GENERAL
1.01 SUMMARY

A. This section describes active ceiling mounted chilled


beams.
B. Model DISA

1.02 SUBMITTALS

A. Submit as specified herein.


B. Submit for review:
a. Product data for all items. Data shall be
complete with the following information:
1. Operating weight and dimensions
of assembled units.
2. Performance data, including supply
airflow, water flow rate, water pressure
drop, and inlet static pressure.
3. Construction details, including materials of
construction and fastening methods.

PART 2 PRODUCTS
2.01 MANUFACTURERS

A. Units shall be model DISA with diffuser with throw pattern as specified on drawings.
B. Considering the innovative technology utilized to engineer
and manufacturer the applied equipment specified for this
project the following substitution considerations shall apply
to any manufacture requesting prior approval:
a. Fifteen day prior to bid date any manufacturer
who would like to be considered shall
submit the following information via certified
mail to the design professional.
b. Submittal documentation for every product
proposed including schedule and performance date
for each with physical and thermal calculations.
c. Any and all costs associated with using a
substituted product shall be the responsibility
of the Mechanical contractor. This includes
but is not limited to redesign fees, additional
piping and ductwork, and controls required.

SPECIFICATIONS

2.02 GENERAL

U42

A. It is the design intent of these specifications to provide a


fully integrated HVAC system with all parts working together.
These induction units need clean, dehumidified primary air
from a dedicated outdoor air unit, hot and chilled water
from a boiler and chiller, piping, and controls to coordinate
each component to perform as intended. Changes, modifications, or substitutions on any component will impact all the
other parts of the system and cannot be made without a
careful review of all related specifications.
B. Chilled beam unit shall be constant volume primary air
flow units designed to induce a secondary airflow within the
conditioned space using the primary conditioned air supply.
Units shall be designed for ceiling installation with factory
supplied hanging brackets. Hanger rods or other approved
hanging system to be field supplied and installed in the field
by installing contractor.
C. Units shall be equipped with a round low velocity pres-

sure inlet transition, one air plenum and air induction nozzle
plate, a supply and return chilled water piping connection,
one supply and return hot water piping connection, and one
combination supply/return air grille for effective room air
distribution. The grille shall be hinged and secured in place
with tool-less safety fasteners to provide full access to the
return air side of the coil. The unit shall be capable of inducing the secondary airflow within the conditioned space using
the velocity pressure of the primary airflow. This secondary
air must flow directly from the room to the unit and shall
not use the ceiling as a return air plenum. Active beam units
using the ceiling plenum as a return air path are not acceptable.
D. Each unit shall be equipped with a multiple row water coil
for chilled water and hot water. Latent conditioning of the air
supplied to the space shall be performed at the dedicated
outdoor air unit and controlled by exhaust air humidity sensors.

2.03 CASINGS

A. The entire unit shall be constructed of 20 gauge galvanized G90 sheet metal. The primary air plenum and nozzles
shall be designed and configured to provide uniform air
distribution with low noise operation to all nozzles.

2.04 WATER COIL ASSEMBLY

A. Coils shall be of the hot and chilled water type utilizing


aluminum fins and copper tubes with integral manual air
vent. Coils shall be factory leak tested at 350 PSI water. Coil
connections shall be as indicated on the drawings.
B. Coils must be one flat plate assembly with no interconnecting joints to minimize leakage. Each coil shall be of the
fin plate design surrounding the copper tube wall via fin
spacing of 10 fins per inch.

2.05 PERFORMANCE

A. All chilled beam units shall be rated in accordance with


EN 15116.

PART 3 EXECUTION
3.01 INSTALLATION GENERAL

A. Follow manufacturers installation instructions and recommendations for all equipment.


B. Install chilled beam units in ceiling in such a manner as to
allow easy access to all controls.
C. Using the hanging brackets on each unit supplied by
the manufacturer, attach chilled beam units to supporting
structure using field supplied threaded rod or other secure
hanging system.
D. Provide primary supply air connection and seal with duct
sealer after installation. A volume control balancing damper
shall be installed at the branch takeoffs for each chilled
beam for the air balancing contractor.
E. Provide water supply/return connection and install temperature control valve.

Titus by Schako

Chilled Beam

Linear Active Chilled Beams (continued)

LCBS is a linear active chilled beam


diffuser with 1-way air distribution.
LCBS

Unique linear design provides high capacity,


high induction and low noise levels.
Available in cooling & supply air (CO) or cooling,
heating & supply air (CH) configurations.
Integrated dew-point safety pan.
Return section of diffuser removable without
tools; providing access to interior of unit.
Water coils supplied with manual air vents.
Accessories include disposable or washable filter,
and plenum rated float switch for safety pan.

Standard finish is #26 white paint on diffuser face.


Diffuser is designed to fit into standard 12 x18,
24 x 48, or 24 x 24 modular ceiling grids.
Factory supplied hanging brackets.
Casing constructed of 20 GA galvanized steel.

DESCRIPTION

INSTALLATION

The LCBS 1-way active chilled beam diffusers are designed


for removing high thermal loads from the space. Supplied
with tempered and dehumidified primary air, to handle
the latent load, the beam addresses the remaining loads
in the space with a heat exchanger installed in the unit.
Decoupling the latent and sensible loads takes advantage of
the superior volumetric heat capacity of water. The reduced
the volume of air that must be delivered to the space results
in reducing air handler capacity and size, smaller duct sizes,
and overall energy savings.

In order to achieve a uniform cooling capacity, the beams


should be connected to the cold water distribution system in
parallel. It is recommended that LCBS units are connected to
the supply air duct system delivering a constant volume of
primary air to maintain optimum induction. When integrated
with room controllers, the units can be used both for single
room and zone control.

In the primary distribution channel, high density


polyethylene injection molded nozzles are precisely
arranged. There are three available nozzle sizes allowing
optimum selection of the primary supply air volume. By
reducing the primary air to meet the minimum requirements
for either room ventilation or latent load in the space, total
system energy costs are reduced.

The LCBS chilled beams are highly configurable, making


them the perfect solution for all applications. These products
have been designed to address heating and cooling loads in
the space, with either a 2-pipe or 4-pipe system. LCBS units
are supplied with a dew-point safety pan and are available
with optional safety overflow switches.

ADVANTAGES
Removal of high thermal loads is
possible in this air/water system.
The size of the supply duct system is minimized
due to reduced primary air requirements.
Substantial reduction in the operating
costs due to low primary air volume.
Improved thermal comfort inside the space.
Individual adjustment of the primary air
volume by means of the nozzle size.
Suitable for all standard ceiling grids.

CLEANING OF THE GRILLE/COIL


To clean the grille and the coil, locate spring loaded
retaining pins. Slide diffuser face towards spring retainers
until pins on opposite side clear the unit frame. Diffuser face
will now be able to swing down for removal. Do not use any
scouring agents for cleaning these components; damage to
the unit construction materials (galvanized steel, aluminum
and copper) and the surface coatings (paint and anodized
surfaces) may occur. After completion of maintenance, grille
must be returned to its original operating position.

LCBS

The primary air, supplied by the air distribution system is


supplied to the mixing chamber via induction nozzles. In
the mixing chamber, room air is induced over a vertically
mounted heat exchanger, to address sensible loads in
the space. The vertical orientation of the coil allows for
induction through all sides of the water coil. The primary air
is mixed with the cooled secondary air and distributed in to
the room through a 1-way multiple louver diffuser supplied
with the unit.

www.titus-hvac.com | www.titus-energysolutions.com

LCBS

U43
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

Linear Active Chilled Beams (continued)

HOUSING

20-gauge galvanized sheet metal construction.

RETURN AIR CHAMBER

Anti-microbial insulation.

SUPPLY AIR PLENUM/CONNECTION

One insulated supply air plenum/primary air chamber.


Round primary air connection.

INDUCTION NOZZLES

DEW-POINT SAFETY PAN

Units have one 3/4 CPVC dewpoint safety pan connection.


Sloped bottom.

DIFFUSER FACE

Lay-in.
Surface mounted.

PRESSURE TAP

Units are supplied with a pressure tap on


the primary air collar for balancing.

High density polyethylene nozzles - three available sizes.

COILS

2-Pipe.
4-Pipe.
Sheet Metal: 16 gauge galvanized.
Fins: 10 aluminum fins per inch.
Leak tested to 350 PSI.

LCBS

CONSTRUCTION

U44
Titus by Schako

Chilled Beam

DIMENSIONS

www.titus-hvac.com | www.titus-energysolutions.com

LCBS 12 X 48
1/2" FPT CWR
1/2" FPT CWS

45 1/8

1/2" FPT HWR

1/2" FPT HWR


10"
1/2" FPT HWS

11 7/8

7
13 8 "

4" PRIMARY AIR


CONNECTION

3
48"
3/4" PVC DRAIN

3
47 4 "

1/2" FPT HWS

3
11 4 "

U
LCBS 24 X 48

12 1/2"

1/2" HOLES FOR HANGING


(TYP 4 PLACES)

45 1/4"

1/2" FPT HWR

2 3/4

6"

2 5/32
3 3/4

4 1/4"

3 3/4"
3 1/4"

2 1/8"
6 5/8
23 3/4"

1 3/4"
9 3/4"

3/4" PVC DRAIN

4 3/8"

22 17/32

1/2" FPT HWS

2 1/4

7 3/4"

1/2" FPT CWR

1/2" FPT CWS

47 3/4"

2 1/8"

4 3/8"

7 3/4

1 3/32"
21"
23 3/4"

47 3/4"
45 1/4"

DIMENSIONS

8 5/8"

1 1/16

23 3/4"

21 3/32

12 1/2"

8 7/8

6 3/4

22 1/2

U45
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS
LCBS 24 X 24
4"

INDUCTION UNIT
COIL

1 1/8
5 1/2

RETURN AIR
PLENUM

12 1/2 9 1/2

3/4" PVC DRAIN

5 1/2
1 3/4

FIELD SUPPLIED
HANGING ROD (QTY OF 4)

23 3/4

Model TCMS (Side View)


20 7/8
1/2" FPT HWR

1/2" FPT CWR

16 1/2

1/2" FPT CWS

16 1/2
1/2" FPT HWS

HANGING BRACKET
(LOCATED ON ALL SIDES)
23 3/4

DIMENSIONS

Model LCBS (Front View)

U46
Titus by Schako

Chilled Beam

PERFORMANCE DATA

Size

Nozzle
Type

[ft]
LF
24 x 24
HF

LF

12 x 48

MF

HF

LF 1 Row

LF 2 Row

MF 1 Row
24 x 48
MF 2 Row

HF 1 Row

HF 2 Row

Primary Air

Cooling

Heating

Ps

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

NC Sound

Throw
T100

0.4

39

1768

1164

2932

2125

NC20

10

0.7

48

2124

1339

3463

2481

NC26

18
16

1.0

57

2469

1545

4014

2838

NC31

0.4

64

2734

1702

4436

3101

NC20

12

0.7

84

3474

2093

5567

3693

NC30

18

1.0

100

4051

2388

6439

4100

NC35

17

0.4

26

1230

892

2122

1817

NC27

22

4.70

3.90

0.7

36

1699

1251

2950

2545

NC33

22

1.0

44

2068

1510

3578

3088

NC38

22
22

0.4

42

1975

0.7

57

2605

1.0

71

3160

6.40

1432

3407

1887

4492

2274

5434

5.20

2937

NC27

3848

NC33

22

4606

NC38

22

0.4

61

2767

2003

4770

4078

NC27

22

0.7

83

3618

2580

6198

5179

NC33

22

1.0

102

4317

3042

7359

6010

NC38

22

0.4

30

1419

1032

2451

2179

NC27

22

0.7

37

1747

1275

3022

2645

NC33

22

1.0

44

2068

1510

3578

3088

NC38

18

0.4

59

2687

1937

4624

3942

NC27

22

0.7

75

3311

2365

5676

4777

NC33

22

1.0

89

3842

2726

6568

5449

NC38

18

0.4

49

2280

1651

3931

3367

NC27

22

0.7

61

2767

2003

4770

4078

NC33

22

1.0

74

3272

0.4

95

4058

6.40

www.titus-hvac.com | www.titus-energysolutions.com

LCBS 2 PIPE

2427

5699

4947

NC38

18

2884

6942

5.30

5744

NC27

22
22

0.7

121

4995

3493

8488

6771

NC33

1.0

147

5903

4108

10011

7715

NC38

18

0.4

64

2886

2083

4969

4236

NC27

22

0.7

83

3618

2580

6198

5179

NC33

22

1.0

102

4317

3042

7359

6010

NC38

18

0.4

126

5177

3603

8780

6935

NC27

22

0.7

160

6302

4616

10918

8566

NC33

22

203

7863

5074

12937

9050

NC38

18

PERFORMANCE BASED ON:


Room Air Temperature = 75BF
Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

PERFORMANCE DATA

COOLING:

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

U47
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA
LCBS 4 PIPE
Size

Nozzle
Type

[ft]
LF
24 x 24
HF

LF

12 x 48

MF

HF

LF 1 Row

LF 2 Row

MF 1 Row
24 x 48
MF 2 Row

HF 1 Row

PERFORMANCE DATA

HF 2 Row

Primary Air

Cooling

Heating

Ps

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

NC Sound

Throw
T100

0.4

39

1768

1164

2932

1298

NC20

10

0.7

48

2124

1339

3463

1408

NC26

18
16

1.0

57

2469

1545

4014

1503

NC31

0.4

64

2734

1702

4436

1561

NC20

12

0.7

84

3474

2093

5567

1629

NC30

18

1.0

100

4051

2388

6439

1635

NC35

17

0.4

26

1193

813

2005

1203

NC27

22

4.70

0.20

0.7

36

1641

1138

2779

1455

NC33

22

1.0

44

1995

1375

3370

1579

NC38

22
22

0.4

42

1906

0.7

57

2500

1.0

71

3028

4.20

1305

3211

1685

4185

2000

5028

0.20

1537

NC27

1739

NC33

22

1850

NC38

22

0.4

61

2654

1780

4434

1779

NC27

22

0.7

83

3470

2247

5717

1899

NC33

22

1.0

102

4152

2616

6768

1927

NC38

22

0.4

30

1372

941

2313

1309

NC27

22

0.7

37

1690

1164

2854

1459

NC33

22

1.0

44

1995

1375

3370

1579

NC38

18

0.4

59

2577

1726

4303

1751

NC27

22

0.7

75

3175

2074

5249

1862

NC33

22

1.0

89

3691

2366

6057

1913

NC38

18

0.4

49

2194

1492

3686

1640

NC27

22

0.7

61

2654

1780

4434

1779

NC33

22

1.0

74

3130

2123

5253

1927

NC38

18

0.4

95

3902

4.20

2493

6395

0.20

1931

NC27

22
22

0.7

121

4829

2980

7809

1911

NC33

1.0

147

5738

3465

9203

1838

NC38

18

0.4

64

2765

1845

4610

1801

NC27

22

0.7

83

3470

2247

5717

1899

NC33

22

1.0

102

4152

2616

6768

1927

NC38

18

0.4

126

5006

3064

8070

1894

NC27

22

0.7

160

6198

3612

9810

1883

NC33

22

1.0

203

7863

3965

11828

1457

NC38

18

PERFORMANCE BASED ON:


COOLING:

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

U48
Titus by Schako

Chilled Beam

SUGGESTED SPECIFICATIONS

1.01 SUMMARY

A. This section describes active ceiling mounted chilled


beams.
B. Model LCBS Size 48 x 24, 48 x 12, and 24 x 24

1.02 SUBMITTALS

A. Submit as specified herein.


B. Submit for review:
a. Product data for all items. Data shall be
complete with the following information:
1. Operating weight and dimensions
of assembled units.
2. Performance data, including water-tube,
airflow, water pressure drop, air-side pressure
drop, and noise and air velocities.
3. Construction details, including materials of
construction and fastening methods.

PART 2 PRODUCTS
2.01 MANUFACTURERS

A. Units shall be model LCBS with a [48 x 24]


[48 x 12][24 x 24] diffuser with one way
linear air pattern as specified on drawings.
B. Considering the innovative technology utilized
to engineer and manufacturer the applied
equipment specified for this project the following
substitution considerations shall apply to any
manufacture requesting prior approval:
a. Fifteen day prior to bid date any manufacturer
who would like to be considered shall
submit the following information via certified
mail to the design professional.
b. Submittal documentation for every product
proposed including schedule and performance date
for each with physical and thermal calculations.
c. Any and all costs associated with using a
substituted product shall be the responsibility
of the Mechanical contractor. This includes
but is not limited to redesign fees, additional
piping and ductwork, and controls required.

2.02 GENERAL

2.03 CASINGS

A. The entire unit shall be constructed of 20 gauge galvanized G90 sheet metal. The primary air plenum and nozzles
shall be designed and configured to provide uniform air
distribution with low noise operation to all nozzles.

2.04 INDUCTION NOZZLES

A. Induction nozzles shall be aerodynamically designed and


made of HDPE Petrothene plastic (Hytrel 4069). Each nozzle
shall incorporate a tapered design allowing the airflow to enter the nozzle more effectively and perform more efficiently
without dirt build up.

2.05 WATER COIL ASSEMBLY

A. Coils shall be of the hot and chilled water type utilizing


aluminum fins and copper tubes with integral manual air
vent. Coils shall be factory leak tested at 350 PSI water. Coil
connections shall be as indicated on the drawings.
B. Coils must be one flat plate assembly with no interconnecting joints to minimize leakage. Each coil shall be of the
fin plate design surrounding the copper tube wall via fin
spacing of 10 fins per inch. The coil tubes shall be designed
with .016 thick copper walls.
Titus by Schako

SPECIFICATIONS

A. It is the design intent of these specifications to provide a


fully integrated HVAC system with all parts working together.
These induction units need clean, dehumidified primary air
from a dedicated outdoor air unit, hot and chilled water
from a boiler and chiller, piping, and controls to coordinate
each component to perform as intended. In addition to the
items mentioned above that are specified on other sections
in division 15, wiring and power requirements in division 16
may also be impacted. Changes, modifications, or substitutions on any component will impact all the other parts of the
system and cannot be made without a careful review of all
related specifications.
Chilled beam unit shall be constant volume primary airflow
units designed to induce a secondary airflow within the
conditioned space using the primary conditioned air supply.
Units shall be designed for ceiling installation with factory

supplied hanging brackets. Hanger rods or other approved


hanging system to be field supplied and installed in the field
by installing contractor.
C. Units shall be equipped with a [6][4] round low velocity
pressure inlet transition, one air plenum and air induction nozzle plate, a supply and return chilled water piping
connection, [one supply and return hot water piping connection], one 3/4 condensate drain connection, and one
combination supply/return air grille for effective room air
distribution. The grille shall have a removable center core to
provide full access to the return air side of the coil. The unit
shall be capable of inducing the secondary airflow within the
conditioned space using the velocity pressure of the primary
airflow. This secondary air must flow directly from the room
to the unit and shall not use the ceiling as a return air plenum. Active beam units using the ceiling plenum as a return
air path are not acceptable.
D. Each LCBS unit shall be equipped with a multiple row
water coil for chilled water and hot water. Latent conditioning of the air supplied to the space shall be performed at
the dedicated outdoor air unit and controlled by exhaust air
humidity sensors.
E. For non-drainable applications, a sloped 1 1/2 deep drainable condensate pan shall be standard [with a UL recognized safety float switch shipped loose for field installation
by the installing contractor. Wiring of the float switches to
be done by contractor in field.]
F. The LCBS unit shall be supplied with a [23 by 23 ]
[47 by 23 ][47 by 11 ] supply/return diffuser
to evenly distribute the mixed primary air in 1-way throw
pattern. The diffuser shall fit into a standard ceiling grid.
Single slot linear diffusers are not acceptable.
The diffuser shall fit into a standard ceiling grid. The return
portion of the diffuser shall be removable for access to
interior of unit without tools. Water connections are female
national pipe copper thread connections 1/2 in size.

www.titus-hvac.com | www.titus-energysolutions.com

PART 1 GENERAL

U49

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS

Chilled Beam

C. The water coil assembly shall consist of a two row or


three row .016 thick copper tube wall and aluminum fins
for cooling and one row coil for heating. The heating coil
row shall be mounted on the return side of the cooling. A
drainable condensate pan shall be provided to collect any
condensate that might form. Drip trays are unacceptable as
a drain pan.
D. Control valves for cooling and heating can control one
or more induction units in a given zone.

2.06 QUALITY ASSURANCE

A. All chilled beam units shall be tested by an independent


nationally recognized testing laboratory for coil performance, throws, and sound levels.

PART 3 EXECUTION
3.01 INSTALLATION GENERAL

SPECIFICATIONS

A. Follow manufacturers installation instructions and recommendations for all equipment.


B. Install chilled beam units in ceiling in such a manner as
to allow easy access to all controls.
C. Using the hanging brackets on each unit supplied by
the manufacturer, support chilled beam units to supporting
structure using field supplied threaded rod or other secure
hanging system.
D. Provide primary supply air connection and seal with duct
sealer after installation. A volume control balancing damper
shall be installed at the branch takeoffs for each chilled
beam for the air balancing contractor. A static pressure port
is factory supplied on the aerodynamic inlet fitting so the
balancing contractor can read via a pressure airflow gage
the inlet pressure to the induction terminal and set the
proper pressure to meet the scheduled airflow/pressure.
E. Provide water supply/return connection and install temperature control valve.
F. Connect the condensate drain to available building drains
as required on plans.

U50
Titus by Schako

Chilled Beam

TCM2 is a modular active chilled beam


diffuser with 4-way air distribution.
TCM2

Unique linear design provides high capacity,


high induction and low noise levels.
Available in cooling & supply air (CO) or cooling,
heating & supply air (CH) configurations.
Integrated dew-point safety pan.

Diffuser face on 48 x 48 unit is shipped loose for


field mounting. The 24 x 24 unit ships complete.

Supply/Return diffuser removable with out


tools; providing access to interior of unit.

Factory supplied hanging brackets.

Accessories include disposable or washable filter,


and plenum rated float switch for drain pan.

Casing constructed of 20 GA galvanized steel.


Closed cell, anti-microbial poly foam insulation.

Standard finish is #26 white paint on diffuser face.

DESCRIPTION
The TCM2 4-way active chilled beam diffusers are designed
for removing high thermal loads from the space. This model
was designed specifically to meet the unique requirements
of high population density spaces; depending on the unit
size, the TCM2 can handle between 60 and 475 CFM of
ventilation (primary) air. Supplied with tempered and
dehumidified primary air, to handle the latent load, the
beam addresses the remaining loads in the space with
a heat exchanger installed in the unit. Decoupling the
latent and sensible loads takes advantage of the superior
volumetric heat capacity of water. The reduced the volume
of air that must be delivered to the space results in reducing
air handler capacity and size, smaller duct sizes, and overall
energy savings.
In the primary distribution channel, high density
polyethylene injection molded nozzles are precisely
arranged. There are three available nozzle sizes allowing
optimum selection of the primary supply air volume. By
reducing the primary air to meet the minimum requirements
for either room ventilation or latent load in the space, total
system energy costs are reduced.

The TCM2 chilled beams are highly configurable, making


them the perfect solution for all applications. These products
have been designed to address heating and cooling loads in

the space, with either a 2-pipe or 4-pipe system. TCM2 units


are supplied with a dew-point safety pan and are available
with optional safety overflow switches.

INSTALLATION
In order to achieve a uniform cooling capacity, the beams
should be connected to the cold water distribution system
in parallel. It is recommended that TCM2 chilled beams
are connected to the supply air duct system delivering
a constant volume of primary air to maintain optimum
induction. When integrated with room controllers, the units
can be used both for single room and zone control.

ADVANTAGES
Removal of high thermal loads is
possible in this air/water system.
Designed to accommodate the ventilation
requirements of high population density areas.
The size of the supply duct system is minimized,
due to reduced primary air requirements.
Substantial reduction in the operating
costs, due to low primary air volume.
Improved thermal comfort inside the space.
Individual adjustment of the primary air
volume by means of the nozzle size.
Suitable for all standard ceiling grids.

CLEANING OF THE GRILLE/COIL


To clean the grille and the coil, locate spring loaded
retaining pins. Slide diffuser face towards spring retainers
until pins on opposite side clear the unit frame. Diffuser face
will now be able to swing down for removal. Do not use any
scouring agents for cleaning these components; damage to
the unit construction materials (galvanized steel, aluminum
Titus by Schako

TCM2

The primary air, supplied by the air distribution system is


supplied to the mixing chamber via induction nozzles. In
the mixing chamber, room air is induced over a vertically
mounted heat exchanger, to address sensible loads in
the space. The vertical orientation of the coil allows for
induction through all sides of the water coil. The primary air
is mixed with the cooled secondary air and distributed in to
the room through a 4-way concentric diffuser supplied with
the unit.

www.titus-hvac.com | www.titus-energysolutions.com

Thermal Comfort Modules


TCM2

U51

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

Thermal Comfort Modules (continued)


and copper) and the surface coatings (paint and anodized
surfaces) may occur. After completion of maintenance, grille
must be returned to its original operating position.

DIFFUSER FACE

CONSTRUCTION

PRESSURE TAP:

HOUSING

Lay-in
Surface mounted
Units are supplied with a pressure tap on the primary air
collar for balancing

20-gauge galvanized sheet metal construction.

RETURN AIR CHAMBER:

Anti-microbial insulation.

SUPPLY AIR PLENUM/CONNECTION:

One insulated supply air plenum/primary air chamber.


Round primary air connection.

INDUCTION NOZZLES:

Each unit contains one continuous 360 degree nozzle


plate.
High density polyethylene nozzles three available sizes.

COILS:

2-Pipe
4-Pipe
Sheet Metal: 16 gauge galvanized
Fins: 10 aluminum fins per inch
Leak tested to 350 PSI

DEW-POINT SAFETY PAN:

TCM2

Units have one 3/4 CPVC dew-point safety pan


connection.
Sloped bottom

U52
Titus by Schako

Chilled Beam

DIMENSIONS

3/4" PVC DRAIN

23 3/4"
3/4" PVC DRAIN

4"
23 3/4"

4"

21 1/8"

23 3/4"

1/2" FPT HWR


20"

3/4" CWR

3/4" CWS

www.titus-hvac.com | www.titus-energysolutions.com

TCM2 24 X 24

1/2" FPT HWS

21"
HANGAR BRACKET
(ON BOTHS IDES)

1/2"

DETAIL A
SCALE 1 : 4

6 9/16"

2 1/16"

13 15/16"

1"

3/4"

20 1/8"

10 1/16"

15 1/4"
9 3/16"

23 3/4"

3/4" PVC DRAIN

Note: dimensions are in inches or mm.

DIMENSIONS
U53
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS
TCM2 48 X 48

13 27/32"
9 9/16"
3 3/16"

47 3/4"
37 17/32"

3/4" PVC DRAIN


CONNECTION

2"

13 13/32"
39 1/8"

47 3/4"
19 9/16"

37 9/16"

47 3/4"

10 13/16"

18 1/32"

2 1/2"
1/2" FPT HWR
3/4" FPT CWR

HANGING BAR
(BOTH SIDES)

1/2"

4 1/4"
3 25/32"

3/4" FPT CWS


1/2" FPT HWS

DETAIL A
SCALE 1 : 5
1"

3/4"

11"

35 5/8"

8"

4"
20"

17 29/32"

17 27/32"
11 17/32"
37 17/32"
47 3/4"

3/4" PVC DRAIN


CONNECTION

DIMENSIONS

Note: dimensions are in inches or mm.

U54
Titus by Schako

Chilled Beam

PERFORMANCE DATA

Size

Nozzle
Type

[ft]
LF

24 x 24

MF

HF

LF

48 x 48

MF

HF

Primary Air

Cooling

Heating
NC Sound

Throw

Ps

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

0.4

60

2602

1830

4432

3512

NC18

16

0.7

83

3439

2363

5802

4390

NC27

16

1.0

105

4216

2845

7061

5093

NC33

14

0.4

78

3261

2259

5520

4229

NC18

16

0.7

106

4253

2857

7110

5103

NC27

16

1.0

135

5229

3255

8484

5837

NC33

14

0.60

0.50

T100

0.4

90

3692

2521

6213

4627

NC18

16

0.7

124

4879

3227

8106

5579

NC27

16

1.0

155

6004

3546

9550

6235

NC33

14

0.4

186

7555

5345

12900

9121

NC18

16

0.7

263

10188

6165

16353

10886

NC27

16

1.0

317

12279

6868

19147

11732

NC33

16

0.4

242

9374

5866

15240

10494

NC18

16

0.7

342

13248

7013

20261

11684

NC27

16

1.0

412

15959

7868

23827

12643

NC33

16

0.4

279

10807

6383

17190

11161

NC18

16

0.7

395

15301

7711

23012

12594

NC27

16

1.0

476

18438

8419

26857

12958

NC33

16

1.70

www.titus-hvac.com | www.titus-energysolutions.com

TCM2 2 PIPE

1.40

PERFORMANCE BASED ON:


COOLING:

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

HEATING:

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:
Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

PERFORMANCE DATA
U55
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA
TCM2 4 PIPE
Size

Nozzle
Type

[ft]
LF

24 x 24

MF

HF

LF

48 x 48

MF

HF

Primary Air

Cooling

Heating
NC Sound

Throw

Ps

Vair

Qair

Dpw

Qcoil

QTotal

Dpw

QTotal

[in wg]

[CFM]

[BTUH]

[ft wg]

[BTUH]

[BTUH]

[ft wg]

[BTUH]

0.4

60

2602

1830

4432

2126

NC18

16

0.7

83

3439

2363

5802

2346

NC27

16

1.0

105

4216

2845

7061

2446

NC33

14

0.4

78

3261

2259

5520

2317

NC18

16

0.7

106

4253

2857

7110

2441

NC27

16

1.0

135

5229

3255

8484

2447

NC33

14

0.60

0.20

T100

0.4

90

3692

2521

6213

2388

NC18

16

0.7

124

4879

3227

8106

2457

NC27

16

1.0

155

6004

3546

9550

2392

NC33

14

0.4

186

7555

5345

12900

4021

NC18

16

0.7

263

10188

6165

16353

3729

NC27

16

1.0

317

12279

6868

19147

3336

NC33

16

0.4

242

9374

5866

15240

3852

NC18

16

0.7

342

13248

7013

20261

3025

NC27

16

1.0

412

15959

7868

23827

2415

NC33

16

0.4

279

10807

6383

17190

3624

NC18

16

0.7

395

15301

7711

23012

2598

NC27

16

1.0

476

18438

8419

26857

1691

NC33

16

1.70

0.60

PERFORMANCE BASED ON:


COOLING:

Room Air Temperature = 75BF


Primary Air Temperature = 55BF
Water Supply Temperature = 57BF
Water Flow Rate = 1.25 gpm

HEATING:

Ps
Vair
Qair
Qcoil
QTotal
Dpw

Unit Inlet Pressure [in wg]


Primary Air Flow Rate [CFM]
Capacity, Primary Air [BTUH]
Capacity, Water Coil [BTUH]
Capacity, Unit Total [BTUH]
Water Coil Pressure Drop [ft wg]

PERFORMANCE DATA

Room Air Temperature = 70BF


Primary Air Temperature = 55BF
Water Supply Temperature = 120BF
Water Flow Rate = 0.5 gpm

LEGEND:

U56
Titus by Schako

Chilled Beam

SUGGESTED SPECIFICATIONS

1.01 SUMMARY

A. This section describes active chilled beams.

1.02 SUBMITTALS

A. Submit as specified herein.


B. Submit for review:
a. Product data for all items. Data shall be
complete with the following information:
1. Operating weight and dimensions
of assembled units.
2. Performance data, including water-tube,
airflow, water pressure drop, air-side pressure
drop, and noise and air velocities.
3. Construction details, including materials of
construction and fastening methods.

PART 2 PRODUCTS
2.01 MANUFACTURERS

A. Units shall be model TCM2 with supplied [24 x


24] [48 x 48] diffuser as specified on drawings.
B. Considering the innovative technology utilized
to engineer and manufacturer the applied
equipment specified for this project the following
substitution considerations shall apply to any
manufacture requesting prior approval:
a. Fifteen day prior to bid date any manufacturer
who would like to be considered shall
submit the following information via certified
mail to the design professional.
b. Submittal documentation for every product
proposed including schedule and performance date
for each with physical and thermal calculations.
c. Any and all costs associated with using a
substituted product shall be the responsibility
of the Mechanical contractor. This includes
but is not limited to redesign fees, additional
piping and ductwork, and controls required.

2.02 GENERAL

2.03 CASINGS

A. The entire unit shall be constructed of 20 gauge galvanized sheet metal. The primary air plenum and nozzles shall
be designed and configured to provide uniform air distribution with low noise operation to all nozzles.
B. The air diffuser shall be removable for access to the interior coil area for cleaning.

2.04 INDUCTION NOZZLES

A. Induction nozzles shall be aerodynamically designed and


made of HDPE Petrothene plastic (Hytrel 4069). Each nozzle
shall incorporate a tapered design allowing the airflow to enter the nozzle more effectively and perform more efficiently
without dirt build up.

SPECIFICATIONS

A. It is the design intent of these specifications to provide a


fully integrated HVAC system with all parts working together.
These induction units need clean, dehumidified primary air
from a dedicated outdoor air unit, hot and chilled water
from a boiler and chiller, piping, and controls to coordinate
each component to perform as intended. In addition to the
items mentioned above that are specified on other sections
in division 15, wiring and power requirements in division 16
may also be impacted. Changes, modifications, or substitutions on any component will impact all the other parts of the
system and cannot be made without a careful review of all
related specifications.
B. Chilled beam unit shall be constant volume primary air
flow units designed to induce a secondary airflow within the
conditioned space using the primary conditioned air supply.
Units shall be designed for ceiling installation with factory
supplied hanging brackets. Hanger rods or other approved
hanging system to be field supplied and installed in the field

by installing contractor.
C. Units shall be equipped with round duct primary air
intake, one air plenum and air induction nozzle plate, one
chilled/hot water coil, a supply and a return chilled water
piping connection, a supply and a return hot water piping
connection, one 3/4 condensate drain connection, and one
combination supply/return air grille for effective room air
distribution. The grille shall have a removable center core to
provide full access to the return air side of the coil. The unit
shall be capable of inducing the secondary airflow within the
conditioned space using the velocity pressure of the primary
airflow. This secondary air must flow directly from the room
to the unit and shall not use the ceiling as a return air plenum. Active beam units using the ceiling plenum as a return
air path are not acceptable.
D. Each TCM2 unit shall be equipped with one water coil for
chilled water and for hot water. Latent conditioning of the air
supplied to the space shall be performed at the dedicated
outdoor air unit and controlled by exhaust air humidity sensors.
E. Each TCM2 unit shall consist of one primary air connection, one nozzle plenum with a set of air induction nozzles,
one chilled water and hot water coil, water piping connections, a condensate drain connection and supply/return air
grille. [For non-drainable applications, a drainable condensate pan with a safety float switch attached to the drain pan
shall be provided by the induction unit manufacturer to shut
off the chilled water coil if condensate should accumulate.]
F. The TCM2 unit shall be supplied with a [23 by 23
] or [47 by 47 ] supply/return diffuser to evenly
distribute the mixed primary air in a 360 degree pattern.
The diffuser shall fit into a standard ceiling grid. The center
portion of the diffuser for return air shall be removable for
access to interior of unit without tools. The primary air connection is a single [4] or [8] diameter duct collar which
directs the primary air to the nozzles. Water connections are
female national pipe thread connections.
G. The TCM2 unit has one drain pan. This drain pan must
be [1 ] or [2] in depth and sloped in the direction of the
condensate connection.

www.titus-hvac.com | www.titus-energysolutions.com

PART 1 GENERAL

2.05 WATER COIL ASSEMBLY

A. Coils shall be of the hot and chilled water type utilizing


aluminum fins and copper tubes with integral manual air
vent. Copper tube wall shall be a minimum .033 thickness.
Titus by Schako

U57

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS
Coils shall be factory leak tested at 350 PSI water. Coil connections shall be as indicated on the drawings.
B. Coil must be one continuous assembly to minimize leakage.
C. The water coil assembly shall consist of a two row copper
tube and aluminum fins coil for cooling and one row coil for
heating. A drainable condensate pan shall be provided.
D. Control valves for cooling and heating can control one or
more chilled beams in a given zone.
E. Coils must be one flat plate assembly with no interconnecting joints to minimize leakage. Each coil shall be of the
fin plate design surrounding the copper tube wall via fin
spacing of 10 fins per inch. The coil tubes shall be designed
with .016 thick copper walls.

2.06 QUALITY ASSURANCE

A. All chilled beam units shall be tested by an independent


nationally recognized testing laboratory for coil performance,
throws, and sound levels.

PART 3 EXECUTION
3.01 INSTALLATION - GENERAL

A. Follow manufacturers installation instructions and recommendations for all equipment.


B. Install chilled beam units in ceiling in such a manner as to
allow easy access to all controls.
C. Using the hanging brackets on each unit supplied by
the manufacturer, support chilled beam units to supporting
structure using field supplied threaded rod or other secure
hanging system.
D. Provide primary supply air connection and seal with duct
sealer after installation.
E. Provide water supply/return connection and install temperature control valve.
F. Connect the condensate drain to available building drains
if required on plans.

SPECIFICATIONS

U58
Titus by Schako

Chilled Beam

SPB is a linear passive chilled beam diffuser.

SPB

Unique design accommodates both


recessed and exposed mounting.
Available in 2-pipe configuration.
Available as diffuser shell (no coil/piping).
Standard finish is RAL 9010 white
paint on diffuser face.

DESCRIPTION
Passive chilled beams are primarily used to provide
comfortable sensible cooling, and can be used in many
heating applications as well. The primary mode of heat
transfer is by convection, with a percentage of heat transfer
transmitted through radiation. During cooling, warm room
air rises to the ceiling area; cool air around the coil sinks
down to the occupied area as a result of the higher density.
As the cool air descends in to the space, more warm air is
drawn over the coil creating a convective current that drives
the system.
The exposed face of the passive beam is constructed from
either painted perforated stainless steel, or a linear bar
grille. The cooling strips are available in lengths of 4 feet
to 14 feet in intervals of 2 feet. The beams are designed
for integration into a suspension ceiling or for exposed
mounting, suspended below the ceiling surface.

ADVANTAGES
SPB models designed to accommodate recessed
or exposed installation with a single model.
Easy cleaning of the water coil and the housing.
Quick and simple installation.
Provide comfortable, effective heating
and cooling to the space.

The diagram shows the approximate cooling capacity Pc in


BTUH at a water flow rate of 0.8 gpm and a temperature
difference between room air and the average water
temperature of 14.5 F.

MOUNTING INFORMATION
Mounting brackets that can slide along the longitudinal axis
are mounted on the beam, 2 per beam.
Alternatively, mounting shackles can be provided with are
fastened to the beam and rest on the T-shaped support
profiles of the false ceiling having a center-to-center
distance of 600 mm. This reduces the mounting time as well
as the mounting costs. The number of shackles required per
beam, depending on length, is noted in the table below.
Beam Length

Shackles required

4 to 6

8 to 10

12 to 14

www.titus-hvac.com | www.titus-energysolutions.com

Linear Passive Chilled Beams


SPB

Quick selection chart

SPB
U59

L (ft.)
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

Linear Passive Chilled Beams (continued)

CLEANING OF THE GRILLE/COIL


The top side of the beam is open allowing direct access to
cleaning the coil. The beam grilles are sectioned to allow
access to the coil by pushing up individual sections and
sliding them over an adjacent section. A vacuum with brush
attachment is recommended for maximum effectiveness. Do
not use any scouring agents for cleaning these components;
damage to the unit construction materials (galvanized
steel, aluminum and copper) and the surface coatings
(paint and anodized surfaces) may occur. After completion
of maintenance, grille must be returned to its original
operating position.

PERFORATED SHEET GRILLE (-SR)

Stainless steel painted to RAL 9010 (white).


46% free area, round perforations.

LINEAR BAR GRILLE (-PA)

Extruded aluminum profile painted to RAL 9010 (white).

WATER COIL

Galvanized sheet steel frame.


Mechanically bonded aluminum fins.
Smooth copper tubes 15 x 1.0 mm.
Integrated manual air vent.
Maximum working pressure, 200 psi.

ACCESSORIES
UNIT EXTENSION

U
CONSTRUCTION

Available in lengths from inch to 12 inches


total unit length must not exceed 14 feet.
Used to adjust the beam length to match ceiling
architecture, or when the strips are installed
in rows or exposed applications, allowing
for concealment of water connections.
Extension has open ends, allowing for piping
to be passed through the extension piece.
The grille face can is easily removable
for access to water connections.

HOUSING

SPB

Galvanized sheet steel painted to RAL 9010 (white).

U60
Titus by Schako

Chilled Beam

DIMENSIONS

www.titus-hvac.com | www.titus-energysolutions.com

SPB 17-IN NOMINAL WIDTH

Piping Configuration:
2-pipe connection (15 mm Dia.)
located on end of diffuser
Nominal
Length

Actual
Lengths (L)

4ft

3.9ft

6ft

5.9ft

8ft

7.9ft

10ft

9.8ft

12ft

11.8ft

14ft

13.8ft

Note: dimensions are in inches or mm.

DIMENSIONS
U61
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS

SPB 12-IN NOMINAL WIDTH

Piping Configuration:
2-pipe connection (15 mm Dia.)
located on end of diffuser
Nominal
Length

Actual
Lengths (L)

4ft

3.9ft

6ft

5.9ft

8ft

7.9ft

10ft

9.8ft

12ft

11.8ft

14ft

13.8ft

DIMENSIONS

Note: dimensions are in inches or mm.

U62
Titus by Schako

Chilled Beam

PERFORMANCE DATA
Cooling capacity per unit length (BTUH/ft)
PC0.8 for passive beams, SPB

AMOUNT OF WATER = 0.8 GPM


(BTU/Hr.ft)

Please note! This diagram is based on tests according to


the Nordtest method, which are conducted with a very
small temperature difference between air entering the
beam and the average room temperature 3.5 feet above
the floor. For installations with concentrated sources of heat
at or near the ceiling, the actual temperature difference 2
to 4BF. In this case, beams should be selected taking this
into consideration. In practice, the strip will have a higher
capacity based on the increased temperature difference.

www.titus-hvac.com | www.titus-energysolutions.com

TECHNICAL DATA - COOLING

U
LEGEND:

Pc
L
Pco8
Dt
Dtw
qw
Dpw
W

Capacity [BTUH]
Length, Nominal [ft]
Capacity @ 0.8 gpm per length [BTUH/ft]
Temperature difference, avg. water temperature vs. room air temperature [BF]
Temperature difference, entering water temperature vs. leaving water temperature [BF]
Water flow rate [gpm]
Water Coil Pressure Drop [ft wg]
unit width [in]

CORRECTION OF THE COOLING EFFECT OF AMOUNTS OF WATER UNEQUAL TO 0.8 GPM

PERFORMANCE DATA
U63
Titus by Schako

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA

Chilled Beam

AMOUNT OF WATER (GPM)

(BTUH)

PERFORMANCE DATA

PRESSURE DROP, WATER (FT WG)

U64
Titus by Schako

PERFORMANCE DATA
Criteria/design conditions:
Max. length of strip - 14 feet
Required cooling capacity - 2400 BTUH
Room air temperature - 75BF
Entering water temperature - 57BF
Leaving water temperature - 61BF

A correction must be made to the beam performance based


on the diagram below to adjust for water flow rates other
than 0.8 gpm is K = Pc1.3 vs Pc0.8 = 1.04. Thus, due the
higher amount of water, the actual capacity is 4% higher
than the value shown in the diagram. Pc = 1.04 x 215 = 224
BTUH/ft.
Required effective length (coil length) Leff = 2400/223 =
10.8ft.

Solution:
Mean coil temperature = (57+61)/2 = 59BF
Difference between room air temperature and mean coil
temperature Dt = 75-59 = 16BF.
According to the diagram below, the cooling capacity, PC0.8
for the 17-inch wide beam at a water flow rate of 0.8 gpm is
215 BTUH/ft.
(BTU/Hr.ft)

Minimum unit length = 10.8ft + .3ft = 11.1ft. The next


larger beam length, of 12 feet will be required to provide
the required cooling in the space.

www.titus-hvac.com | www.titus-energysolutions.com

SELECTION EXAMPLE

Chilled Beam

According to the water coil pressure drop diagrams, the


pressure loss, based on unit effective length (Leff) of the
above the beam in this selection example Dpw is 4.35 ft wg.

In the capacity versus water flow rate diagram the amount


of water qw is 1.3 gpm at Dtw = 4BF and the cooling capacity
is 2400 BTUH.
(BTUH)

PERFORMANCE DATA
U65
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

SUGGESTED SPECIFICATIONS
PART 1 GENERAL
1.01 SUMMARY

A. This section describes passive ceiling mounted chilled


beams.

1.02 SUBMITTALS

A. Submit as specified herein.


B. Submit for review:
a. Product data for all items. Data shall be
complete with the following information:
1. Operating weight and dimensions
of assembled units.
2. Performance data, including water flow
rate and water pressure drop.
3. Construction details, including materials of
construction and fastening methods.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Units shall be model SPB with lengths


and widths as specified on drawings.
B. Considering the innovative technology utilized
to engineer and manufacturer the applied
equipment specified for this project the following
substitution considerations shall apply to any
manufacture requesting prior approval:
a. a. Fifteen day prior to bid date any
manufacturer who would like to be considered
shall submit the following information via
certified mail to the design professional.
b. b. Submittal documentation for every product
proposed including schedule and performance date
for each with physical and thermal calculations.
c. c. Any and all costs associated with using a
substituted product shall be the responsibility
of the Mechanical contractor. This includes
but is not limited to redesign fees, additional
piping and ductwork, and controls required.

2.03 CASINGS

A. The entire unit shall be constructed of 20 gauge galvanized G90 sheet metal, painted RAL 9010 (white).

2.05 WATER COIL ASSEMBLY

A. Coils shall be of the chilled water type utilizing aluminum


fins and copper tubes with integral manual air vent. Coils
shall be factory leak tested at 350 PSI water. Coil connections shall be as indicated on the drawings.
B. Coils must be one flat plate assembly with no interconnecting joints to minimize leakage. Each coil shall be of the
fin plate design surrounding the copper tube wall via fin
spacing of 9 fins per inch.

PART 3 EXECUTION
3.01 INSTALLATION - GENERAL

A. Follow manufacturers installation instructions and recommendations for all equipment.


B. Install chilled beam units in ceiling in such a manner as to
allow easy access to all controls.
C. Using the hanging brackets on each unit supplied by
the manufacturer, support chilled beam units to supporting
structure using field supplied threaded rod or other secure
hanging system.
D. Provide water supply/return connection and install temperature control valve.

SPECIFICATIONS

2.02 GENERAL

A. Units shall be designed for ceiling installation with factory


supplied hanging brackets. Hanger rods or other approved
hanging system to be field supplied and installed in the field
by installing contractor.
C. A supply and return chilled water piping connection,
and grille fascia. The grille shall be designed in such a way
where sections can be removed to provide full access to the
water coil.
D. Each unit shall be equipped with a multiple row water coil
for chilled water and hot water. Latent conditioning of the air
supplied to the space shall be performed at the dedicated
outdoor air unit and controlled by exhaust air humidity sensors.

U66
Titus by Schako

Chilled Beam

Constructed from extruded


aluminum profiles.
Single circuit for each sail as ordered;
hard copper connection between
individual blades.
Standard finish is RAL 9010 white powder coating.

ALPETY HKL

ALPETY FKL

FKL and HKL are architectural


radiant ceiling products.

Supplied with mounting equipment


for fixed on site installation.
Available with hinged mounting equipment
allowing sails to swing down up to 45B.

15mm diameter pipe connections.

DESCRIPTION
The Alpety radiant ceiling systems are water driven radiation
systems whose advantages include silent cooling, low
energy consumption, and create a high degree of thermal
comfort through draft free cooling and even temperature
distribution in the space. However, it must be taken into
account that these systems must be supported by additional
mechanical ventilation and means to address the latent
cooling requirements of the space.

ADVANTAGES
Radiant heat transfer increases occupancy comfort.
Reduces energy consumption by utilizing
heat transfer capacity of water.
Minimize airflow and noise in the space.
Quick and simple installation.
Several models integrate seamlessly
in to any architecture.

ALPETY (FKL, HKL)

Radiant ceilings systems emit heating and cooling by both


convection and radiation. During cooling, ambient air
near the ceiling cools and falls to the occupied area, due
to its higher density. In contrast, the ambient air heated
by heat sources located in the room will rise. This gives
rise to convection currents with very low flow velocities.
Furthermore, the ceiling emits cooling and heating to
the surrounding surfaces in the area by radiation. When
radiation reaches one of these surfaces, the radiant energy
is absorbed by that surface. The radiant heat transfer from
the panels to surfaces and/or occupants in the room will
occur regardless of the ambient air temperature. Radiant
heat transfer results in high thermal comfort and leads
to the ambient temperature feeling cooler than it actually
is during cooling and warmer in heating. Depending on
the percentage of the active ceiling surface to the overall
surface of the room (including floor, walls, windows,
furniture, etc.) the temperature perceived by the occupant
will be 2.5 to 5 degrees cooler/warmer than it actually
is. This effect has the advantage that the room requires
less conditioning than a traditional system, introducing an
additional opportunity for energy savings.

In conjunction with the customers own metal or acoustic


ceiling tiles, the Alpety ceiling elements can be integrated in
the room to create the ceiling faade, models FKL and HKL,
or in combination with suspended ceiling systems with SKS
models. The individual ceiling elements are usually joined to
one another using flexible hoses. Connections can also be
made using hard copper piping and soft soldering.

www.titus-hvac.com | www.titus-energysolutions.com

Radiant Ceiling Panels


ALPETY (FKL, HKL)

Since the sensible cooling no longer has to be introduced


into the room along with ventilation air, the volume of
air supplied can be reduced to the meet the fresh air
requirements. By reducing the volume of air supplied the
possibility of drafts and noise levels are greatly reduced.
This leads to increased occupancy comfort. Addressing
thermal loads using the Alpety products makes use of the
increased heat transfer capacities of water, as compared to
air, increasing overall system efficiency.

U67
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS
ALPETY (FKL, HKL)

U
Model

FKL
HKL

Blade
Width
(LB)

Pipe
Spacing
(A)

2 Blades

3 Blades

4 Blades

5 Blades

6 Blades

5 1/4

11 1/4

17

23

29

34 3/4

7 3/4

15

22 3/4

30 3/4

38 1/2

46 1/2

5 /4

11 /4

17

23

29

34 3/4

Available
Nominal
Lengths* (ft)
2
4

DIMENSIONS

6
8

*Actual length =
Nominal Length - 1/4
Note: dimensions are in inches or mm.

U68
Titus by Schako

Chilled Beam

PERFORMANCE DATA

Alpety-FKL 134
Cooling output - based on percentage of active ceiling surface area (BTUH/ft2)
tm
(F)

20%

25%

30%

35%

40%

45%

50%

55%

60%

65%

70%

75%

80%

20.0

19.7

19.7

19.3

19.0

18.7

18.4

18.1

17.4

17.1

16.8

16.5

15.9

11

24.7

24.4

24.1

23.8

23.5

22.8

22.5

22.2

21.6

21.2

20.6

20.3

19.7

13

29.5

29.2

28.5

28.2

27.9

27.3

27.0

26.3

25.7

25.1

24.7

24.1

23.5

14

34.6

33.9

33.6

33.0

32.7

32.0

31.4

30.8

30.1

29.5

28.9

28.2

27.3

16

39.6

39.0

38.4

37.7

37.4

36.8

36.1

35.2

34.6

33.6

33.0

32.3

31.4

18

44.4

43.8

43.1

42.5

41.9

41.2

40.3

39.6

38.7

37.7

37.1

36.1

35.2

20

49.2

48.5

47.9

47.2

46.6

45.7

45.0

44.1

42.8

42.2

41.2

40.3

39.0

22

54.2

53.6

53.0

52.0

51.4

50.4

49.5

48.5

47.2

46.3

45.3

44.4

43.1

www.titus-hvac.com | www.titus-energysolutions.com

ALPETY FKL

Alpety-FKL 180
Cooling output - based on percentage of active ceiling surface area (BTUH/ft2)
tm
(F)

20%

25%

30%

35%

40%

45%

50%

55%

60%

65%

70%

75%

80%

20.0

19.7

19.7

19.3

19.0

18.7

18.4

18.1

17.4

17.1

16.8

16.5

15.9

11

23.8

23.8

23.5

23.1

22.5

22.2

21.9

21.2

20.9

20.6

20.0

19.7

19.0

13

28.5

28.2

27.9

27.6

27.0

26.6

26.0

25.7

25.1

24.7

24.1

23.5

22.5

14

32.7

32.3

32.0

31.7

31.1

30.8

30.1

29.5

28.9

28.2

27.6

27.0

26.0

16

37.7

37.4

37.1

36.5

35.8

35.2

34.6

33.9

33.3

32.7

31.7

31.1

30.1

18

42.2

41.9

41.2

40.6

40.0

39.3

38.7

37.7

37.1

36.5

35.5

34.6

33.6

20

46.6

46.3

45.7

45.0

44.4

43.8

42.8

41.9

40.9

40.3

39.3

38.4

37.1

22

51.4

51.1

50.4

49.5

48.8

47.9

46.9

46.0

45.0

44.4

43.1

42.2

40.9

PERFORMANCE DATA
U69
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

PERFORMANCE DATA
ALPETY HKL
Alpety-HKL 134

Cooling output - based on percentage of active ceiling surface area (BTUH/ft2)


tm
(F)

20%

25%

30%

35%

40%

45%

50%

55%

60%

65%

70%

75%

80%

22.5

22.2

21.9

21.2

21.2

20.6

20.3

20.0

19.7

19.0

18.7

18.4

17.8

11

27.9

27.6

27.3

26.6

26.3

25.7

25.4

24.7

24.4

23.8

23.1

22.8

22.2

13

33.3

33.0

32.3

31.7

31.4

30.8

30.4

29.8

29.2

28.5

27.9

27.3

26.3

14

38.7

38.4

37.7

37.1

36.5

35.8

35.2

34.6

33.9

33.3

32.3

31.7

30.8

16

44.1

43.8

43.1

42.2

41.5

40.9

40.3

39.3

38.7

37.7

37.1

36.1

35.2

18

49.8

49.2

48.5

47.6

46.9

46.0

45.3

44.4

43.4

42.5

41.5

40.6

39.6

20

55.2

54.2

53.6

52.6

52.0

51.1

50.1

49.2

48.2

47.2

46.0

45.0

43.8

22

60.6

59.6

59.0

57.7

57.1

56.1

55.2

53.9

53.0

51.7

50.7

49.5

48.2

PERFORMANCE DATA

U70
Titus by Schako

Chilled Beam

Radiant Ceiling Panels (continued)

SKS panels are architectural radiant ceiling products.


ALPETY SKS

Constructed from aluminum or steel sheet metal,


aluminum extrusion, and copper tubing.
Optional perforated face pattern includes acoustical
fleece to enhance room sound absorption.
Single water circuit per panel.
15mm diameter pipe connections.

DESCRIPTION
The Alpety radiant ceiling systems are water driven radiation
systems whose advantages include silent cooling, low
energy consumption, and create a high degree of thermal
comfort through draft free cooling and even temperature
distribution in the space. However, it must be taken into
account that these systems must be supported by additional
mechanical ventilation and means to address the latent
cooling requirements of the space.

Available mounting brackets and support


rails for easy field installation.

In conjunction with the customers own metal or acoustic


ceiling tiles, the Alpety ceiling elements can be integrated in
the room to create the ceiling faade, models FKL and HKL,
or in combination with suspended ceiling systems with SKS
models. The individual ceiling elements are usually joined to
one another using flexible hoses. Connections can also be
made using hard copper piping and soft soldering.

ADVANTAGES

Radiant heat transfer increases occupancy comfort.


Reduces energy consumption by utilizing
heat transfer capacity of water.
Minimize airflow and noise in the space.
Quick and simple installation.
Several models integrate seamlessly
in to any architecture.

ALPETY SKS

Radiant ceilings systems emit heating and cooling by both


convection and radiation. During cooling, ambient air
near the ceiling cools and falls to the occupied area, due
to its higher density. In contrast, the ambient air heated
by heat sources located in the room will rise. This gives
rise to convection currents with very low flow velocities.
Furthermore, the ceiling emits cooling and heating to
the surrounding surfaces in the area by radiation. When
radiation reaches one of these surfaces, the radiant energy
is absorbed by that surface. The radiant heat transfer from
the panels to surfaces and/or occupants in the room will
occur regardless of the ambient air temperature. Radiant
heat transfer results in high thermal comfort and leads
to the ambient temperature feeling cooler than it actually
is during cooling and warmer in heating. Depending on
the percentage of the active ceiling surface to the overall
surface of the room (including floor, walls, windows,
furniture, etc.) the temperature perceived by the occupant
will be 2.5 to 5 degrees cooler/warmer than it actually
is. This effect has the advantage that the room requires
less conditioning than a traditional system, introducing an
additional opportunity for energy savings.

Standard finish is RAL 9010 white powder coating.

www.titus-hvac.com | www.titus-energysolutions.com

ALPETY SKS

Since the sensible cooling no longer has to be introduced


into the room along with ventilation air, the volume of
air supplied can be reduced to the meet the fresh air
requirements. By reducing the volume of air supplied the
possibility of drafts and noise levels are greatly reduced.
This leads to increased occupancy comfort. Addressing
thermal loads using the Alpety products makes use of the
increased heat transfer capacities of water, as compared to
air, increasing overall system efficiency.

U71
Titus by Schako

Chilled Beam

www.titus-hvac.com | www.titus-energysolutions.com

DIMENSIONS

ALPETY SKS

Available
Nominal
Lengths* (ft)
2
4
6
8

Piping Configuration:
2-pipe connection (15 mm Dia.)

DIMENSIONS

Note: dimensions are in inches or mm.

U72
Titus by Schako

Chilled Beam

SUGGESTED SPECIFICATIONS

A. This section describes ceiling mounted radiant heating


and cooling products.
B. Model [SKS][FKL][HKL]

1.02 SUBMITTALS

PART 3 EXECUTION

A. Submit as specified herein.


B. Submit for review:
a. Product data for all items. Data shall be
complete with the following information:
1. Operating weight and dimensions
of assembled units.
2. Performance data, including water flow
rate and water pressure drop.
3. Construction details, including materials of
construction and fastening methods.

PART 2 PRODUCTS

3.01 INSTALLATION - GENERAL

A. Follow manufacturers installation instructions and recommendations for all equipment.


B. Install chilled beam units in ceiling in such a manner as to
allow easy access to all controls.
C. Using the hanging brackets on each unit supplied by
the manufacturer, support chilled beam units to supporting
structure using field supplied threaded rod or other secure
hanging system.
D. Provide water supply/return connection and install temperature control valve.

www.titus-hvac.com | www.titus-energysolutions.com

1.01 SUMMARY

C. SKS Panels are to be [non-perforated][perforated and


supplied with acoustic fleece backing].
D. FKL & HKL constructed from multiple aluminum extrusions with 15 mm diameter copper tubing mechanically
bonded to aluminum profiles. Individual extrusions attached
to braces used for product mounting.

PART 1 GENERAL

2.01 MANUFACTURERS

A. Units shall be model [SKS][FKL][HKL] with


lengths and widths as specified on drawings.
B. Considering the innovative technology utilized
to engineer and manufacturer the applied
equipment specified for this project the following
substitution considerations shall apply to any
manufacture requesting prior approval:
a. Fifteen day prior to bid date any manufacturer
who would like to be considered shall
submit the following information via certified
mail to the design professional.
b. Submittal documentation for every product
proposed including schedule and performance date
for each with physical and thermal calculations.
c. Any and all costs associated with using a
substituted product shall be the responsibility
of the Mechanical contractor. This includes
but is not limited to redesign fees, additional
piping and ductwork, and controls required.

2.02 GENERAL

SPECIFICATIONS

A. Units shall be designed for ceiling installation with factory


supplied hanging brackets. Hanger rods or other approved
hanging system to be field supplied and installed in the field
by installing contractor.
B. A supply and return water piping connection will be supplied on each panel/sail.
D. Latent conditioning of the air supplied to the space shall
be performed at the dedicated outdoor air unit and controlled by exhaust air humidity sensors.

2.03 CONSTRUCTION

A. Units are to be constructed of [galvanized sheet metal]


[aluminum sheet metal][aluminum extrusion] painted RAL
9010 (white).
B. SKS Panels are constructed with multiple aluminum extrusions glued to panel surface, and 15 mm diameter copper
tubing mechanically bonded to aluminum extrusions.

U73
Titus by Schako

Notes

Chilled Beam

grilles & diffusers index

Y
www.titus-hvac.com | www.titus-energysolutions.com

www.titus-hvac.com | www.titus-energysolutions.com

Model Number Index

MODEL NUMBER INDEX

Y2

Grilles & Diffusers Index

Model Number Index................................Page

Model Number Index................................Page

NUMBERS
1700 (L, S)...........................................I44
3 (FL, FS).............................................G22
4 (FL, FS).............................................G24
8F.........................................................I18
8FF.......................................................I18
8R........................................................I18
8RF......................................................I18
8SS......................................................I18
23 (RL, RS)..........................................G21
25 (RL, RS)..........................................G23
30 (RFL, RFS).......................................I23
30 (RL, RS)...........................................I22
33 (RFL, RFS).......................................I23
33 (RL, RS)...........................................I22
55 (FL, FS)...........................................G24
56 (FL, FS)...........................................G22
60 (FL, FS)............................................I29
63 (FL, FS)............................................I29
111/112 (RL, RS)..................................G9
121/122 (RL, RS)................................G10
131/132 (RL, RS)................................G11
250................................................... F216
250-AA............................................. F216
271/272 (FL, FS)...................................G8
271/272 (RL, RS)..................................G7
300/301 (FL, FS).................................. H9
300/301 (RL, RS)................................. H8
300/301 (RL-HD, RS-HD)................... H11
300/301 (RL-SS, RS-SS)..................... H10
350 (FL-FS, ZFL-ZFS).......................... H24
350 (RL-RS, ZRL-ZRS)........................ H23
350 (RL-SS, RS-SS)............................ H25
350/355 (RLF-RSF, FLF-FSF, SS)........ H39
355 (FL-FS, ZFL-ZFS).......................... H27
355 (RL-RS, ZRL-ZRS)........................ H26

AG-45.................................................K19
AG-65.................................................K15
AG-65 (S, L)........................................K16
AG-75...................................................K8
AG-85...................................................K9
AG-95.................................................K13
AG-95-AA...........................................K13
AG-100.................................................K7
AGR-35-AAS.......................................K12
Alpety FKL......................................... U67
Alpety HKL......................................... U67
Alpety SKS......................................... U71

A
AG-125...............................................K14
AG-15.................................................K10
AG-225...............................................K19
AG-35.................................................K11

C
CSR................................................... F227
CSR-P............................................... F227
CT-480................................................ F49
CT-481................................................ F49
CT-540................................................ F49
CT-541................................................ F49
CT-580................................................ F49
CT-581................................................ F49
CT-PP-0............................................... F49
CT-PP-3............................................... F49
CT-700 (L, S)........................................I45
D
D-75......................................................K8
D-100....................................................K7
DAT................................................... F146
DAT-NT............................................. F149
DISA.................................................. U18
DISA-V............................................... U35
DL........................................................I57
DL-SV...................................................I58
DV180.................................................T44
DVBC..................................................T22
DVC1...................................................T55
DVCP..................................................T67
DVHC..................................................T49
DVIR...................................................T26
DVR3..................................................T38

Model Number Index (continued)

Grilles & Diffusers Index

DVRI...................................................T32
DVRI-HC Plexicon...............................T71
DVVC..................................................T61

FBR-25................................................C21
FBR-30................................................C21
FBRI-10...............................................C21
FBRI-15...............................................C21
FBRI-20...............................................C21
FBRI-25...............................................C21
FBRI-30...............................................C21
FFD.....................................................R38
FFDE...................................................R38
FFDR...................................................R38
FFDER.................................................R38
FL-10-HT...............................................C9
FL-15-HT...............................................C9
FL-20-HT...............................................C9
FL-25-HT...............................................C9
FL-10-HT...............................................C9
FL-10-JT.............................................C10
FL-15-JT.............................................C10
FL-20-JT.............................................C10
FL-25-JT.............................................C10
FL-10-JT.............................................C10
FlexaBoot............................................K26
FlexRight............................................K25
FT-10...................................................C32
FT-15...................................................C32
FT-20...................................................C32
FTB-10................................................C32
FTB-15................................................C32
FTB-20................................................C32
FTBI-10...............................................C32
FTBI-15...............................................C32
FTBI-20...............................................C32
FTI-10.................................................C32
FTI-15.................................................C32
FTI-20.................................................C32

E
EG..............................................................K17
EG (S, L).................................................... K18
EOS........................................................... D65
EOS-NT..................................................... D69
EOSI.......................................................... D65
EOSI-NT.................................................... D69

F
FBBO-10.............................................C21
FBBO-15.............................................C21
FBBO-20.............................................C21
FBBO-25.............................................C21
FBBO-30.............................................C21
FBC-10................................................C20
FBC-15................................................C20
FBC-20................................................C20
FBC-25................................................C20
FBC-30................................................C20
FBMC-10............................................C19
FBMC-15............................................C19
FBMC-20............................................C19
FBMC-25............................................C19
FBMC-30............................................C19
FBP-10................................................C22
FBP-15................................................C22
FBP-20................................................C22
FBP-25................................................C22
FBP-30................................................C22
FBPI-10...............................................C22
FBPI-15...............................................C22
FBPI-20...............................................C22
FBPI-25...............................................C22
FBPI-30...............................................C22
FBR-10................................................C21
FBR-15................................................C21
FBR-20................................................C21

H
HEPALERT..........................................R46
HEPA Filter.........................................R47
HTSK-10.............................................C20
HTSK-15.............................................C20
HTSK-20.............................................C20

MODEL NUMBER INDEX

Model Number Index................................Page

www.titus-hvac.com | www.titus-energysolutions.com

Model Number Index................................Page

Y3

www.titus-hvac.com | www.titus-energysolutions.com

Model Number Index (continued)

MODEL NUMBER INDEX

Y4

Grilles & Diffusers Index

Model Number Index................................Page

Model Number Index................................Page

HTSK-25.............................................C20
HTSK-30.............................................C20

MFRB-10............................................C28
ML-37................................................. F15
ML-38................................................. F15
ML-39................................................. F15
ML-40................................................. F15
ML-37-NT........................................... F32
ML-38-NT........................................... F32
ML-39-NT........................................... F32
ML-40-NT........................................... F32
ML-TZ................................................. F15
MLF-37............................................... F21
MLF-38............................................... F21
MLF-39............................................... F21
MLF-40............................................... F21
MLR-37............................................... F15
MLR-38............................................... F15
MLR-39............................................... F15
MLR-40............................................... F15
MLR-37-NT......................................... F32
MLR-38-NT......................................... F32
MLR-39-NT......................................... F32
MLR-40-NT......................................... F32
MLR-TZ............................................... F15
MLRF-37............................................. F21
MLRF-38............................................. F21
MLRF-39............................................. F21
MLRF-40............................................. F21
MP-37................................................. F33
MP-38................................................. F33
MP-39................................................. F33
MP-40................................................. F33
MP-37-SP........................................... F33
MP-38-SP........................................... F33
MP-39-SP........................................... F33
MP-40-SP........................................... F33
MPI-37............................................... F33
MPI-38............................................... F33
MPI-39............................................... F33
MPI-40............................................... F33
MPI-37-SP.......................................... F21
MPI-38-SP.......................................... F21
MPI-39-SP.......................................... F21

J
JFA (L, S).............................................I52
JTSK-10..............................................C20
JTSK-15..............................................C20
JTSK-20..............................................C20
JTSK-25..............................................C20
JTSK-30..............................................C20
L
LCBS.................................................. U43
LineaTec-AL........................................R26
LineaTec-SS........................................R26
LL-1..................................................... F63
LL-2..................................................... F63
M
MB-30.............................................. F151
MB-30-NT........................................ F159
MBR-30............................................ F151
MBR-30-NT...................................... F159
MC-37................................................ F21
MC-38................................................ F21
MC-39................................................ F21
MC-40................................................ F21
MC-480.............................................. F53
MC-481.............................................. F53
MC-540.............................................. F53
MC-541.............................................. F53
MC-580.............................................. F53
MC-581.............................................. F53
MC-PP-0............................................. F53
MC-PP-3............................................. F53
MCD................................................. F126
MCD-AA........................................... F126
MF-10.................................................C28
MFB-10...............................................C28
MFBI-10.............................................C28
MFI-10................................................C28
MFR-10...............................................C28

Grilles & Diffusers Index

Model Number Index (continued)

Model Number Index................................Page

MPI-40-SP.......................................... F21

PXP-DF.................................................E6
PXP-NT............................................. F108

N
N-1..................................................... D48
N-1-D................................................. D52
N-1-DR.............................................. D53
N-1-R................................................. D49
O
OMNI................................................ F131
OMNI-AA.......................................... F131
OMNI-AA-NT.................................... F137
OMNI-NT.......................................... F137
OMNI-RS.......................................... F143

S
SB.......................................................K24
SG-1500FL..........................................J19
SG-3300RL..........................................J16
SG-BG-FM..........................................J29
SG-BG-SLV..........................................J31
SG-LFF................................................J27
SG-LFO................................................J25
SG-SD...................................................J7
SG-PR.................................................J10
SG-PRA...............................................J10
SG-PRT...............................................J10
SG-PS.................................................J13
SG-TDC...............................................J22
SPB.................................................... U59
Spectrum.......................................... F165
SteriTec-AL.........................................R31
SteriTec-SS.........................................R31

T-700 (L, S)..........................................I44


T-Slot................................................. D41
T-Slot-In............................................. D41
T3SQ-0................................................ L10
T3SQ-2.................................................. L8
T3SQ-4.................................................. L7
TBD-10................................................ D8
TBDI-10............................................... D8
TBD-10-FB........................................... D8
TBDI-10-FB.......................................... D8
TBD-30.............................................. D13
TBDI-30............................................. D13
TBD-80.............................................. D23
TBD-80-NT......................................... D39

DESCRIPTIVE PRODUCT INDEX

P
PAR..................................................... F82
PAR-AA............................................... F82
PAR-FR.................................................E6
PAR-NT............................................. F108
PAS..................................................... F82
PAS-AA............................................... F82
PAS-FR.................................................E6
PAS-NT............................................. F108
PCS................................................... F102
PCS-AA............................................. F102
PCS-DF............................................. F102
PCS-NT............................................. F108
PDR..................................................... F82
PDS..................................................... F82
PF.......................................................K23
PF-SS..................................................K23
PFA.....................................................K23
PMC.................................................. F113
PMC-DF............................................ F113
PMR.................................................. F113
PSS..................................................... F97
PSS-AA............................................... F97
PSS-DF............................................... F97
PSS-NT............................................. F108
PXP..................................................... F95
PXP-AA............................................... F95

R
RadiaTec-AL........................................R17
RadiaTec-SS........................................R17
R-OMNI............................................ F139

www.titus-hvac.com | www.titus-energysolutions.com

Model Number Index................................Page

Y5

www.titus-hvac.com | www.titus-energysolutions.com

Model Number Index (continued)

DESCRIPTIVE PRODUCT INDEX

Y6

Grilles & Diffusers Index

Model Number Index................................Page

Model Number Index................................Page

TBDI-80............................................. D23
TBDI-80-NT....................................... D39
TBD-FR...............................................E17
TBDI-FR..............................................E17
TBDR-FR.............................................E17
TBF-AA............................................. F223
TBR-30............................................... D20
TBR-80............................................... D36
TBR-80-NT......................................... D39
TCM2................................................. U51
TDC................................................... F170
TDC-AA............................................. F170
TDC-FR...............................................E14
TDC-NT............................................. F190
TDCA................................................ F170
TDC-AA............................................. F170
TDC-AA-NT....................................... F190
TDCA-FR.............................................E14
TDF-DynaFuser.................................. D58
TDF-NT.............................................. D63
TDF-R................................................. D60
TDFI................................................... D58
TDFI-NT............................................. D63
TDFR-NT............................................ D63
TDRM.................................................K22
TDV................................................... F192
TDV-AA............................................. F192
TDV-AA-NT....................................... F200
TDV-NT............................................. F200
TDX................................................... F202
TDX-AA............................................. F202
TDX-AA-NT....................................... F214
TDX-NT............................................. F214
TLF......................................................R22
TLF-AA................................................R22
TLF-SS................................................R22
TriTec..................................................R13
TriTec-AL.............................................R13
TriTec-SS.............................................R13
TMR.................................................... F70
TMR-AA.............................................. F70
TMRA................................................. F73

TMRA-AA........................................... F73
TMS.................................................. F117
TMS-AA............................................ F117
TMS-FR................................................E9
TMSA................................................ F122
TMSA-AA......................................... F122
TMSA-FR............................................E11
TRM....................................................K21
TRM-S................................................K21
TSW.................................................. F162
TV.......................................................K20
U
US-DL..................................................I61
US-DL-SV.............................................I61
V
V-1...................................................... F79
VersaTec...............................................R9
VersaTec-AL..........................................R9
X
XC-310................................................ F76

Grilles & Diffusers Index

Descriptive Product Index

Descriptive Product...................................Page

300/350 Filter Return Grilles


350/355 (RLF-RSF, FLF-FSF, SS).... H39
Model Number Specifications....... H40
Options & Accessories................... H41
Oversize Grille Constuction............ H43
Screw Hole Location Chart............ H44
Suggested Specifications.............. H40

300/350 Return Grilles


350 (FL-FS, ZFL-ZFS)...................... H24
350 (RL-RS, ZRL-ZRS).................... H23
350 (RL-SS, RS-SS)........................ H25
355 (FL-FS, ZFL-ZFS)...................... H27
355 (RL-RS, ZRL-ZRS).................... H26
Model Number Specifications....... H36
Performance Data...... ....................H28
Suggested Specifications.............. H36
300/350 Supply Grilles
300/301 (FL, FS).............................. H9
300/301 (RL, RS)............................. H8
300/301 (RL-HD, RS-HD)............... H11
300/301 (RL-SS, RS-SS)................. H10
Model Number Specifications....... H19
Performance Data.......................... H12
Suggested Specifications.............. H19

Adjustable Ceiling Diffusers


250................................................ F216
250-AA.......................................... F216
Model Number Specifications...... F221
Optional Disharge Patterns........... F217
Performance Data......................... F218
Suggested Specifications............. F221
AeroBlade Return Grilles
3 (FL, FS).........................................G22
4 (FL, FS).........................................G24

AeroBlade Supply Grilles


111/112 (RL, RS)..............................G9
121/122 (RL, RS)............................G10
131/132 (RL, RS)............................G11
271/272 (FL, FS)...............................G8
271/272 (RL, RS)..............................G7
Model Number Specifications........G19
Performance Data...........................G12
Suggested Specifications...............G19

Application Notes
OR Air Distribution System.............R50
System Sizing & Layout..................R49
Applications
Air Filtration & Quality Control.........R8
Air Motion........................................R6
Air Volume........................................R7
General Cleanroom Information........R6
Personnel Training............................R8
Proper Equipment.............................R8
Architectural Ceiling Diffusers
DAT............................................... F146
Model Number Specifications...... F148
Performance Data..... ....................F147
Suggested Specifications............. F148
DAT-NT.......................................... F149

DESCRIPTIVE PRODUCT INDEX

Accessories
HEPALERT.......................................R46
HEPA Filter......................................R47

23 (RL, RS)......................................G21
25 (RL, RS)......................................G23
55 (FL, FS).......................................G24
56 (FL, FS).......................................G22
Common Size Chart........................G41
Filter Return Grilles........................G26
Model Number Specifications........G35
Narrow Tee Return Grilles..............G25
Performance Data...........................G27
Suggested Specifications...............G35
Options & Accessories....................G37
Oversize Grille Constuction.............G39
Screw Hole Location Chart.............G40

www.titus-hvac.com | www.titus-energysolutions.com

Descriptive Product.....................................Page

Y7

Grilles & Diffusers Index

www.titus-hvac.com | www.titus-energysolutions.com

Descriptive Product Index (continued)

DESCRIPTIVE PRODUCT INDEX

Y8

Descriptive Product.....................................Page

Descriptive Product...................................Page

Model Number Specifications...... F150


Suggested Specifications............. F150
MB-30........................................... F151
MBR-30........................................ F151
Dimensions................................... F152
Model Number Specifications...... F158
Performance Data..... ....................F154
Suggested Specifications............. F157
MB-30-NT..................................... F159
MBR-30-NT.................................. F159
Model Number Specifications...... F160
Suggested Specifications............. F160
OMNI............................................ F131
OMNI-AA...................................... F131
Dimensions................................... F132
Model Number Specifications...... F136
Performance Data..... ....................F134
Suggested Specifications............. F136
OMNI-AA-NT................................ F137
OMNI-AA...................................... F137
Model Number Specifications...... F138
Suggested Specifications............. F138
OMNI-RS...................................... F143
Model Number Specifications...... F145
Performance Data..... ....................F144
Suggested Specifications............. F145
R-OMNI........................................ F139
Model Number Specifications...... F142
Performance Data..... ....................F140
Suggested Specifications............. F142
Spectrum...................................... F165
Dimensions................................... F166
Model Number Specifications...... F169
Performance Data..... ....................F167
Suggested Specifications............. F169
TSW.............................................. F162
Model Number Specifications...... F164
Performance Data..... ....................F163
Suggested Specifications............. F164

Auto-Changeover Diffusers
Accessories.................................... D71
EOS................................................ D65

Model Number Specifications....... D68


Performance Data...... ....................D67
Suggested Specifications.............. D68
EOS-NT.......................................... D69
Model Number Specifications....... D70
Suggested Specifications.............. D70
TDF - DynaFuser............................ D58
Model Number Specifications....... D62
Performance Data.......................... D59
Suggested Specifications.............. D62
TDF-NT.......................................... D63
Model Number Specifications....... D63
Suggested Specifications.............. D63
TDF-R............................................. D60
Model Number Specifications....... D62
Performance Data.......................... D61
Suggested Specifications.............. D62

Basic Cleanroom Terminology


Clean Area......................................R51
Cleanliness Classification (Class)...R51
Cleanroom......................................R51
First Air...........................................R51
High-Effiency Filter (HEPA).............R51
Laminar Flow Cleanroom................R51
Makeup Air.....................................R51
Particle Concentration....................R51
Particle Size....................................R51
Primary Air......................................R51
Secondary Air ................................R51
Ultra Low Particulate Air Filter (ULPA)
........................................................R51
Work Area ......................................R51
Chilled Beam Application Guide
Benefits of Chilled Ceiling Systems
......................................................... U9
Chilled Ceiling Applications........... U10
Chilled Ceiling System Design....... U10
Comfort & IAQ Benefits................... U9
Control of Chilled Ceiling System.. U16
Design Methodology..................... U10
Energy Efficiency & Operational

Descriptive Product Index (continued)

Grilles & Diffusers Index


Descriptive Product...................................Page

Benefits .......................................... U9
First Cost Benefits........................... U9
Heat Transfer................................... U7
History............................................. U6
Induction......................................... U9
Introduction..................................... U6
Practical Design Guidelines........... U10
Product Selection.......................... U13
Psychrometrics................................ U7
Space Design Conditions............... U12
System Design Process................. U12
Theoretical Background................... U7

Accessories.....................................T63
Model Number Specifications........T66
Performance Data....... ....................T64
Suggested Specifications...............T66

Circular Displacement
DVCP..............................................T67
Accessories.....................................T68
Model Number Specifications........T70
Performance Data....... ....................T69
Suggested Specifications...............T70
Commercial/Industrial Louvered Supply Grilles
JFA (L, S).........................................I52
Model Number Specifications.........I56
Options & Accessories.....................I65
Performance Data............................I53
Suggested Specifications................I56
Universal Filter Frames....................I65

Corner Mount Displacement


DVC1...............................................T55
Accessories.....................................T57
Model Number Specifications........T60
Performance Data....... ....................T58
Suggested Specifications...............T60
DVVC..............................................T61

Displacement Ventilation Adjustment


Diffuser Adjustment.......................T77
Displacement Ventilation Application Guide
Acoustical Performance..................T12
Air Change Effectiveness..................T8
Air Pattern Projection.....................T11
Benefits & Limitations......................T9
Contaminant Removal......................T9
Design Examples............................T15
Design Procedure for Displacement
Ventilation .....................................T14
Displacement Ventilation Theory &
Governing Equations......................T12
Energy Considerations......................T9
Heat Sources & Convective Flows..T11
Introduction to Displacement
Ventilation........................................T8
Methods of Evaluation...................T12
Outlet Characteristics.....................T10
Outlet Choices................................T10
References......................................T21
Space Temperature Gradients &
Airflow Rates..................................T11
Supply Air Connections..................T12
The Adjacent Zone..........................T10
Typical Applications..........................T9

DESCRIPTIVE PRODUCT INDEX

Concentric Supply/Return Diffusers


CSR............................................... F227
CSR-P........................................... F227
Dimensions................................... F228
Performance Data..... ....................F229
Suggested Specifications............. F230

Heating & Cooling Displacement Options


DVRI-HC Plexicon...........................T71
DVRI-HC 14 Accessories................T72
DVRI-HC 32 Accessories................T73
Model Number Specifications........T76
Performance Data - Cooling...........T74
Performance Data - Heating...........T75
Suggested Specifications...............T76

www.titus-hvac.com | www.titus-energysolutions.com

Descriptive Product.....................................Page

Y9

www.titus-hvac.com | www.titus-energysolutions.com

Descriptive Product Index (continued)

DESCRIPTIVE PRODUCT INDEX

Y10

Descriptive Product.....................................Page

Door Grilles
CT-700 (L, S)....................................I45
T-700 (L, S).......................................I44
Model Number Specifications.........I47
Options & Accessories.....................I65
Performance Data............................I46
Suggested Specifications................I47
Universal Filter Frames....................I65
Drum Louvers
DL....................................................I57
DL-SV...............................................I58
US-DL..............................................I61
US-DL-SV.........................................I61
Model Number Specifications.........I64
Options & Accessories.....................I65
Performance Data............................I62
Suggested Specifications................I64
Universal Filter Frames....................I65
Eggcrate Return Grilles
50F...................................................I12
50F-NT.............................................I12
50FF.................................................I14
50R-SS.............................................I13
Model Number Specifications.........I17
Options & Accessories.....................I65
Performance Data............................I15
Suggested Specifications................I17
Universal Filter Frames....................I65
Fan Filter Diffusers
FFD.................................................R38
FFDE...............................................R38
FFDR...............................................R38
FFDER.............................................R38
Introduction....................................R38
Dimensions.....................................R39
Model Number Specifications........R45
Options & Accessories....................R43
Performance Data...........................R44
Suggested Specifications...............R45

Grilles & Diffusers Index


Descriptive Product...................................Page

Fire Rated Three Hour Ceiling Diffusers


PAR-FR.............................................E6
PAS-FR..............................................E6
Accessories.......................................E7
Installation Details............................E7
Model Number Specifications..........E8
Suggested Specifications.................E8
TDC-FR...........................................E14
TDCA-FR.........................................E14
Accessories.....................................E15
Installation Details..........................E15
Model Number Specifications........E16
Suggested Specifications...............E16
TBD-FR...........................................E17
TBDI-FR..........................................E17
TBDR-FR.........................................E18
Model Number Specifications........E19
Suggested Specifications...............E19
TMSA-FR........................................E11
Accessories.....................................E12
Installation Details..........................E12
Model Number Specifications........E13
Suggested Specifications...............E13
FlowBar Linear
FL-HighThrow...................................C6
FL-JetThrow......................................C7
Accessories.....................................C19
Acoustical Ceiling Applications......C15
Border Types...................................C17
End Fabrication...............................C18
FlowTee...........................................C32
Hard Ceiling Applications...............C12
Installation Methods......................C16
Model Number Specifications........C49
ModuFlow Series............................C28
Mounting Hardware Installation....C23
Performance Data...........................C34
Side Wall Applications...................C14
Suggested Specifications...............C48

Descriptive Product Index (continued)

GRD Accessories
Air Balancing Devices.......................K7
Duct Accessories............................K25
Mounting Frames...........................K21
Sectorizing Baffle...........................K24
Heavy Duty Bar Return Grilles
30 (RFL, RFS)...................................I23
30 (RL, RS).......................................I22
33 (RFL, RFS)...................................I23
33 (RL, RS).......................................I22
Model Number Specifications.........I28
Options & Accessories.....................I65
Performance Data............................I24
Suggested Specifications................I28
Universal Filter Frames....................I65
60 (FL, FS)........................................I29
63 (FL, FS)........................................I29
Model Number Specifications.........I34
Options & Accessories.....................I65
Performance Data............................I30
Suggested Specifications................I34
Universal Filter Frames....................I65

Linear Active Chilled Beams


DISA............................................... U18
Dimensions.................................... U21
Performance Data...... ....................U29
Suggested Specifications.............. U42
DISA-V........................................... U35
Dimensions.................................... U37
Performance Data...... ....................U39

Suggested Specifications.............. U42


LCBS.............................................. U43
Dimensions.................................... U45
Performance Data...... ....................U47
Suggested Specifications.............. U49
Linear Air Curtain
LineaTec..........................................R26
Continuous Unit Construction........R27
Overview.........................................R26
Dimensions.....................................R27
Model Number Specifications........R30
Optional Plenum Construction.......R27
Performance Data...........................R29
Suggested Specifications...............R30
SteriTec...........................................R31
Dimensions.....................................R33
Flange & Hanger Bracket................R35
Model Number Specifications........R37
Nominal Plenum Lengths...............R34
Overview.........................................R32
Plenum Inlet Locations...................R36
Suggested Specifications...............R37
Linear Bar Diffusers
CT-480............................................. F49
CT-481............................................. F49
CT-540............................................. F49
CT-541............................................. F49
CT-580............................................. F49
CT-581............................................. F49
CT-PP-0........................................... F49
CT-PP-3........................................... F49
Accessories..................................... F53
Dimensions..................................... F50
Installations.................................... F54
Model Number Specifications........ F60
Performance Data........................... F55
Suggested Specifications.............. U60

DESCRIPTIVE PRODUCT INDEX

Laminar Pattern Diffusers


TLF..................................................R22
Dimensions.....................................R23
HEPA Filter Option..........................R23
Model Number Specifications........R25
Overview.........................................R23
Performance Data...........................R24
Suggested Specifications...............R25

Descriptive Product...................................Page

www.titus-hvac.com | www.titus-energysolutions.com

Descriptive Product.....................................Page

Grilles & Diffusers Index

Y11

www.titus-hvac.com | www.titus-energysolutions.com

Descriptive Product Index (continued)

DESCRIPTIVE PRODUCT INDEX

Y12

Grilles & Diffusers Index

Descriptive Product.....................................Page

Descriptive Product...................................Page

Linear Louver Diffusers


LL-1................................................. F63
LL-2................................................. F63
Accessories..................................... F65
Dimensions..................................... F64
Installations.................................... F66
Model Number Specifications........ F69
Performance Data........................... F67
Suggested Specifications.............. U69

N-Slot Series Diffusers


N-1................................................. D48
N-1-D............................................. D52
N-1-DR........................................... D53
N-1-R............................................. D49
Applications................................... D47
Model Number Specifications....... D51
Performance Data.......................... D50
Performance Data - (-D, -DR)........ D54
Suggested Specifications.............. D51

Linear Passive Chilled Beams


SPB................................................ U59
Dimensions.................................... U61
Performance Data...... ....................U63
Suggested Specifications.............. U66
Linear Slot Ceiling Diffusers
ML-37............................................. F15
ML-38............................................. F15
ML-39............................................. F15
ML-40............................................. F15
ML-TZ.............................................. F15
MLR-37........................................... F15
MLR-38........................................... F15
MLR-39........................................... F15
MLR-40........................................... F15
MLR-TZ........................................... F15
Modulinear Plenums...................... F33
Narrow Tee Models........................ F32
Plenum Installations....................... F34
Plenum Model Number
Specifications................................. F48
Plenum Performance Data ............. F35
Plenum Suggested Specifications.. F48
Accessories..................................... F21
Dimensions..................................... F16
Installations.................................... F22
Model Number Specifications........ F30
Performance Data........................... F24
Suggested Specifications............... F30

Nozzle Diffusers
TBF-AA......................................... F223
Model Number Specifications...... F226
Performance Data..... ....................F224
Suggested Specifications............. F226
Perforated Ceiling Diffusers
Model Number Specifications...... F109
Narrow Tee Models...................... F108
Suggested Specifications............. F109
PAR................................................. F82
PAR-AA........................................... F82
PAS................................................. F82
PAS-AA........................................... F82
PDR................................................. F82
PDS................................................. F82
Dimensions..................................... F83
Model Number Specifications........ F93
Performance Data....... ....................F86
Suggested Specifications............... F93
PCS............................................... F102
PCS-AA......................................... F102
PCS-DF......................................... F102
Dimensions................................... F103
Installations.................................. F104
Model Number Specifications...... F107
Performance Data..... ....................F105
Suggested Specifications............. F107
PMC.............................................. F113
PMC-DF........................................ F113

Descriptive Product Index (continued)

Grilles & Diffusers Index


Descriptive Product...................................Page

PMR.............................................. F113
Dimensions................................... F114
Model Number Specifications...... F116
Performance Data..... ....................F115
Suggested Specifications............. F116
PSS................................................. F97
PSS-AA........................................... F97
PSS-DF............................................ F97
Dimensions..................................... F98
Model Number Specifications...... F101
Performance Data..... ....................F100
Suggested Specifications............. F101
PXP................................................. F95
PXP-AA........................................... F95
PXP-DF............................................ F95
Model Number Specifications........ F96
Suggested Specifications............... F96

Model Number Specifications....... D22


Performance Data.......................... D14
Performance Data - TBR-30........... D21
Suggested Specifications.............. D22
TBD-80........................................... D23
TBDI-80......................................... D23
TBR-80........................................... D36
Model Number Specifications....... D38
Performance Data...... ....................D24
Performance Data - TBR-80........... D37
Suggested Specifications.............. D38
TBD-80-NT..................................... D39
TBDI-80-NT.................................... D39
TBR-80-NT..................................... D39
Model Number Specifications....... D40
Suggested Specifications.............. D40

Plenum Slot Adjustable Diffusers


TBD-10............................................. D8
TBD-10-FB....................................... D8
TBDI-10........................................... D8
TBDI-10-FB...................................... D8
Model Number Specifications....... D12
Performance Data........ ....................D9
Suggested Specifications.............. D12
TBD-30........................................... D13
TBDI-30......................................... D13
TBR-30........................................... D20

Radial Pattern Diffusers


RadiaTec.........................................R17
Dimensions.....................................R18
Model Number Specifications........R21
Overview.........................................R17
Performance Data...........................R20
Suggested Specifications...............R21
TriTec..............................................R13
Dimensions.....................................R13
Model Number Specifications........R16
Overview.........................................R13
Performance Data...........................R14
Suggested Specifications...............R16
VersaTec............................................R9
Dimensions.....................................R10
Overview...........................................R9
Model Number Specifications........R12

DESCRIPTIVE PRODUCT INDEX

Perforated Return Grilles


8F.....................................................I18
8FF...................................................I18
8R....................................................I18
8RF..................................................I18
8SS..................................................I18
Model Number Specifications.........I21
Options & Accessories.....................I65
Performance Data............................I19
Suggested Specifications................I21
Universal Filter Frames....................I65

Plenum Slot Fixed Diffusers


T-Slot.............................................. D41
T-Slot-In......................................... D41
Model Number Specifications....... D45
Performance Data...... ....................D42
Suggested Specifications.............. D45

www.titus-hvac.com | www.titus-energysolutions.com

Descriptive Product.....................................Page

Y13

www.titus-hvac.com | www.titus-energysolutions.com

Descriptive Product Index (continued)

DESCRIPTIVE PRODUCT INDEX

Y14

Grilles & Diffusers Index

Descriptive Product.....................................Page

Descriptive Product...................................Page

Performance Data...........................R11
Suggested Specifications...............R12

Performance Data............................I49
Suggested Specifications................I51
Universal Filter Frames....................I65

Radiant Ceiling Panels


Alpety FKL..................................... U67
Dimensions.................................... U68
Performance Data...... ....................U69
Suggested Specifications.............. U73
Alpety HKL..................................... U67
Dimensions.................................... U68
Performance Data...... ....................U70
Suggested Specifications.............. U73
Alpety SKS..................................... U71
Dimensions.................................... U72
Suggested Specifications.............. U73
Rectangular Displacement
DVBC..............................................T22
Accessories.....................................T23
Model Number Specifications........T25
Performance Data....... ....................T24
Suggested Specifications...............T25
DVIR...............................................T26
Accessories.....................................T28
Model Number Specifications........T31
Performance Data....... ....................T29
Suggested Specifications...............T31
DVR3...............................................T38
Accessories.....................................T40
Model Number Specifications........T43
Performance Data....... ....................T41
Suggested Specifications...............T43
DVRI...............................................T32
Accessories.....................................T34
Model Number Specifications........T37
Performance Data....... ....................T35
Suggested Specifications...............T37
Reversible Core Grilles
1700 (L, S).......................................I44
Model Number Specifications.........I51
Options & Accessories.....................I65

Round Ceiling Diffusers


TMR................................................ F70
TMR-AA.......................................... F70
Model Number Specifications........ F72
Performance Data....... ....................F71
Suggested Specifications............... F72
TMRA............................................. F73
TMRA-AA....................................... F73
Model Number Specifications........ F75
Performance Data....... ....................F74
Suggested Specifications............... F75
V-1.................................................. F79
Model Number Specifications........ F81
Performance Data....... ....................F80
Suggested Specifications............... F81
XC-310............................................ F76
Model Number Specifications........ F78
Performance Data....... ....................F77
Suggested Specifications............... F78
Security Products
Application Suggestions.................J34
Options...........................................J33
Typical Installation Methods..........J35
SG-1500FL......................................J19
Model Number Specifications........J21
Performance Data...........................J20
Suggested Specifications...............J21
SG-3300RL......................................J16
Model Number Specifications........J18
Performance Data...........................J17
Suggested Specifications...............J18
SG-BG-FM.......................................J29
Model Number Specifications........J30
Suggested Specifications...............J30
SG-BG-SLV......................................J31
Model Number Specifications........J32
Suggested Specifications...............J32

Grilles & Diffusers Index

Descriptive Product Index (continued)

Descriptive Product...................................Page

SG-LFF............................................J27
Model Number Specifications........J28
Suggested Specifications...............J28
SG-LFO............................................J25
Model Number Specifications........J26
Suggested Specifications...............J26
SG-PR.............................................J10
Model Number Specifications........J12
Performance Data...........................J11
Suggested Specifications...............J12
SG-PS..............................................J13
Model Number Specifications........J15
Performance Data...........................J14
Suggested Specifications...............J15
SG-SD...............................................J7
Model Number Specifications..........J9
Performance Data.............................J8
Suggested Specifications.................J9
SG-TDC............................................J22
Model Number Specifications........J24
Performance Data...........................J23
Suggested Specifications...............J24

Spiral Duct Mounted Grilles


S300 (FL, FS)....................................I35
S301 (FL, FS)....................................I35
S8F...................................................I37
US301 (RL, RS)................................I36
US8F................................................I37
Model Number Specifications.........I42

Square & Rectangular Ceiling Diffusers


TDC............................................... F170
TDCA............................................. F170
Dimensions................................... F171
Model Number Specifications...... F186
Performance Data..... ....................F173
Suggested Specifications............. F186
TDC-AA-NT................................... F190
TDC-NT......................................... F190
Model Number Specifications...... F191
Suggested Specifications............. F191
TDV............................................... F192
TDV-AA......................................... F192
Dimensions................................... F193
Model Number Specifications...... F198
Performance Data..... ....................F194
Suggested Specifications............. F198
TDV-AA-NT................................... F200
TDV-NT......................................... F200
Model Number Specifications...... F200
Suggested Specifications............. F200
TDX............................................... F202
TDX-AA......................................... F202
TDX ADPI Comparison.................. F204
Dimensions................................... F203
Model Number Specifications...... F212
Performance Data..... ....................F206
Suggested Specifications............. F212
TDX-AA-NT................................... F214
TDX-NT......................................... F214
Model Number Specifications...... F214
Suggested Specifications............. F214
TDX, TDV, & TDC Comparison...... F205
Square Ceiling Diffusers
MCD............................................. F126
MCD-AA....................................... F126

DESCRIPTIVE PRODUCT INDEX

Semi-Circular Displacement
DV180.............................................T44
Accessories.....................................T45
Model Number Specifications........T48
Performance Data....... ....................T46
Suggested Specifications...............T48
DVHC..............................................T49
Accessories.....................................T51
Model Number Specifications........T54
Performance Data....... ....................T52
Suggested Specifications...............T54

Options & Accessories.....................I65


Performance Data............................I38
Suggested Specifications................I42
Universal Filter Frames....................I65

www.titus-hvac.com | www.titus-energysolutions.com

Descriptive Product.....................................Page

Y15

www.titus-hvac.com | www.titus-energysolutions.com

Descriptive Product Index (continued)

Descriptive Product.....................................Page

Dimensions................................... F127
Model Number Specifications...... F130
Performance Data..... ....................F128
Suggested Specifications............. F130
TMS.............................................. F117
TMS-AA........................................ F117
Dimensions................................... F118
Model Number Specifications...... F121
Performance Data..... ....................F119
Suggested Specifications............. F121
TMSA............................................ F122
TMSA-AA...................................... F122
Model Number Specifications...... F125
Performance Data..... ....................F123
Suggested Specifications............. F125
Thermal Comfort Modules
TCM2............................................. U51
Dimensions.................................... U53
Performance Data.......................... U55
Suggested Specifications.............. U57

DESCRIPTIVE PRODUCT INDEX

TurboFuser
TBF-AA......................................... F223
Model Number Specifications...... F226
Performance Data..... ....................F224
Suggested Specifications............. F226

Y16

VAV Diffusers
Accessories....................................... L9
Application Guidelines...................... L5
Design Features................................ L4
Master/Drone Wiring........................ L6
Model Number Specifications........ L16
Products........................................... L3
T3SQ-0............................................ L10
T3SQ-2.............................................. L8
T3SQ-4.............................................. L7
Performance Data........................... L12
Suggested Specifications............... L14

Grilles & Diffusers Index

Standard

Standard & Optional Finishes Grilles & Diffusers

#01 Aluminum
Enviro-THANE finish is a tough,
baked-on urethane coating with
superior surface durability for
rough-handling environments. Paint
sample matching is available.

#20 Custom ENVIRO-THERM

#21 Custom ENVIRO-THANE

#34 Natural

#94 Light Bronze

#95 Medium Bronze

#96 Dark Bronze

#101 Luster Clear

#102 Brushed Clear

#103 Luster Gold

#104 Brushed Gold

#105 Luster Black

#106 Brushed Black

#107 Luster Bronze

#108 Brushed Bronze

Custom

#84 Black

Anodized Finishes

#26 White

Anodizing converts the outer layer


of aluminum to a ceramic shell
of aluminum oxide, increasing
resistance to corrosion and the
weather.

#110 Brushed Pewter


Mill Finish refers to sheet metal with
no surface coating or treatment.
For highly corrosive or sanitary
applications, a number of products
are available in 304 stainless steel.

#04 Aluminum

Mill

#109 Luster Pewter

#04 Stainless Steel

Colors on this chart may vary slightly from the actual product. For more accurate color, ask your Titus representative for a color chip sample.

clever. creative. comfort.

Address: 605 Shiloh Rd. Plano, Texas 75074


Office: 972.212.4800
Fax: 972.212.4877
E-mail: titus@titus-hvac.com
Websites: www.titus-hvac.com | www.titus-energysolutions.com
Copyright Titus 2011 | All rights reserved