You are on page 1of 3

NAUTALA L.I.

SCHEME ON MAHENDRA THANAYA RIVER IN SARAVAKOTA (M)


DISCHARGE CALCULATIONS
Ayacut Proposed

Cropping Pattern

2100 Acres
Khariff

ID & Paddy

(Single Season)
Duty Adopted for ID crops

100 Acres/cusec

Duty Adopted for paddy crops

50 Acres/cusec

Discharge Required for ID

1050/100
10.50 cusecs

Discharge Required for Wet crops

1050/50

21.00

Cusecs

10.50+21.0
Total discharge

31.50 Cusecs

Losses @ 20%

6.30

Total discharge including losses

37.80 cusecs

Discharge Required for 12 hours pumping

50.40
or say

51.00

Cusecs

NAUTALA L.I. SCHEME ON MAHENDRA THANAYA RIVER IN SARAVAKOTA (M)


DESIGN OF INTAKE PIPE LINE
Requirement as per Applicant

400000 Lt/day

Total Discharge Required

0.1635 Cusecs

Discharge Required for 4 hours pumping

0.6540 Cusecs

Allowable Velocity for non sand drawal


Area Required

2.0
=

0.6540

ft/sec
Sft

2.0
A
Diameter Of Pipe =

(A x 4/3.142)
say

0.327

Sft

0.645

ft

197

mm

200

mm

0.084

sq.ft

0.168

sq.ft

3.893

ft/sec
mts

However 200 mm Dia RCC NP3 Pipes are required


Alternately, considering 100mm dia pipes,
Area of 100mm pipe =

0.25 x ( 0.328 )2 =

So adopt 2 rows of 100mm , NP3 class RCC pipes


Area of 2 rows of pipe line =
Actual Velocity

2 x 0.084

0.218/0.198 =

Length of Intake Pipe Line

1000

Gradient Adopted

1:600

Bed Fall

1000
600

1.667
S=

1/1000

mts
mts
= 0.00167

Assistant Engineer

Dy. Executive Engineer

Executive Engineer

APSIDC Sub Division APSIDC Sub Division

APSIDC Division

Srikakulam

Srikakulam

Srikakulam