You are on page 1of 64

Test Tools Catalog

Volume 39, 2008

Keeping your world


up and running.
Test Tools Catalog
Volume 39, 2008
Contact us:
Contents United States
General product and sales
Fluke tools for: 771 Milliamp Process Clamp Meter.................. 31 information: 1-800-44-FLUKE
Commercial Electricians....................................... 3 744, 743B, 741B Documenting Process fluke-info@fluke.com
Industrial Electricians........................................... 4 Calibrators............................................................32 Fluke Thermal Imagers:
HVAC/IAQ Technicians......................................... 5 726, 725 Precision Multifunction 1-800-760-4523 (U.S. only) all
Digital Multimeters Process Calibrators.............................................33 other regions 1-425-446-4620
Multimeter Selection Guide................................. 6 724, 714, 712 Temperature Calibrators............34 Service and calibration:
718, 717 Pressure Calibrator, 700 Series 1-888-99-FLUKE
287 and 289 True-rms Logging Multimeters... 7
Pressure Modules................................................35 Parts: 1-800-526-4731
87V Industrial Multimeter.................................... 8
715, 707, 705 Loop Calibrators.........................36 Canada
179 Digital Multimeter.......................................... 9 General product, sales, service,
117 and 115 True-rms Digital Multimeters...... 10 Intrinsically Safe Products parts and calibration information:
116 and 114 True-rms Digital Multimeters...... 11 707Ex, 718Ex, 725Ex, 700PEx, 574-NI, 1-800-36-FLUKE
77 IV Digital Multimeter and 68IS, 87V Ex........................................................ 37 canada@fluke.com
27 Waterproof Multimeter................................. 12 Thermometers Australia
88V Automotive Multimeter.............................. 13 General product and sales
54 Series II Contact Thermometers,
8845A/8846A 6.5 Digit Precision information: (2) 8850-3333
61, 63, 66, 68 Infrared Thermometers.............38
Multimeters.......................................................... 14 Parts: (2) 8850-3333
561, 566, 568, 62 Infrared Thermometers......39 Service and calibration:
8808A 5.5 Digit Multimeter.............................. 15 570 Series Infrared Thermometers .................40 (2) 9771-9300
Earth Ground Testers Thermal Imagers Singapore
1625 and 1623 Geo Earth Ground Testers...... 16 General product and sales
Thermal Imaging and IR Fusion Technology.. 41
1630 Earth Ground Clamp Meter and information: 6799-5566
Ti25, Ti10, Ti20 Thermal Imagers....................42 info.asean@fluke.com
1621 Basic Earth Ground Tester........................17
Ti40FT/Ti50FT Series IR FlexCam Service, parts and calibration:
Power Quality Analyzers Thermal Imagers, SmartView Software.........43 6799-5588
430 Series Power Quality Analyzers................ 18 TiR1, TiR Thermal Imagers................................44 service.asean@fluke.com
345 Power Quality Clamp Meter and TiR4FT, TiR3FT, TiR2FT IR FlexCam Japan
43B Power Quality Analyzer............................. 19 Thermal Imagers.................................................45 General product and sales
1740 Series Three-Phase PQ Loggers..............20 information: +81-3-3434-0180
HVAC/Indoor Air Quality Tools Service, parts and calibration:
1735 Three-Phase Power Logger and 975 AirMeter , 922 Airflow Meter....................46 +81-3-3434-0188
VR1710 Power Quality Recorder....................... 21
971 Temperature Humidity Meter, Other countries: 1+(425) 446-5500
1750 Three-Phase Power Recorder.................22 983 Particle Counter, RLD1 Leak Detector,
1760 Power Quality Recorder, Norma 4000 CO-220 Carbon Monoxide Meter,
and 5000 Precision Power Analyzers..............23 CO-205 Aspirator Kit.......................................... 47 Pictured on front
Clamp Meters cover: Ken Bartlett,
ScopeMeter Test Tools E&I technician for
330 and 320 Series Clamp Meters...................24
ScopeMeter Test Tools Selection Guide...........48 Pogo Gold Mine
902 True-rms HVAC Clamp Meter, in Delta Junction,
120 Series Industrial ScopeMeter Test Tools...49
353 and 355 True-rms Clamp Meters, Alaska, standing in
360 Current Clamp Meter..................................25 190 Series Color ScopeMeter Test Tools..........50
front of a molten
ScopeMeter Accessories..................................... 51 gold pour. To read
Electrical Testers
Accessories a case study on
T+ and T+ Pro Electrical Testers, the mine, visit
T5 Tester, 1AC-II VoltAlert and Accessory Selection Guide.................................52
www.fluke.com/
LVD2 Volt Light ..................................................26 Accessory Sets and Kits.....................................53 flukeplus
Insulation Testers and MegOhmMeters SureGrip Accessories........................................54
Test Leads, Probes, and Clips............................55
1550B Megohmmeter,
1507 and 1503 Insulation Testers.................... 27 Lights, Software, Specialty Accessories.....56-57 More Fluke
1587 and 1577 Insulation Multimeters............28 Current Clamps............................................. 58-59 Info Online
Temperature Accessories.............................60-61
Process Calibration Tools
Cases, Holsters, Fuses................................. 62-63
Process Tools Selection Guide...........................29
Whats new from Fluke.....................back cover
Complete digital
789, 787 Process Meters....................................30 catalog

Application Key Use these icons to find products for your industry.
Newest products
Extended specs
How-to
information
Measurement
safety
Where to buy

www.fluke.com/
catalog
2
Fluke tools for
commercial electricians
Legend
Power Distribution Center

Heat Exchanger

HVAC Blower

Drive Control

Motor and Motor Control Center

Electrical

Fluke Ti10 Thermal Fluke 1587 Insulation Fluke 62 Mini IR


Imager Multimeters Thermometer
Best suited for: Quickly Best suited for: Work on Best suited for:
identifying and tracing motors, generators, cables or Surface temperature
electro-mechanical switch-gear. readings.
problems. Features: Finding heating and
Easy to use and drop- Measuring insulation test ventilation problems.
tested for ruggedness. voltages to 1000 V. Non-contact monitoring
Blended thermal/ Prevents insulation test if of electrical motors and
visible images help voltage > 30 V is detected panels.
identify problems. for added user protection. See page 39 for details.
High resolution and Filter for motor drive
thermal sensitivity. measurements.
See page 42 for details. See page 28 for details.

Fluke T+PRO Fluke 330 Series Fluke 117 Digital


Electrical Tester Clamp Meters Multimeter
Best suited for: Best suited for: Best suited for:
Detecting, confirming, Verifying the presence of Commercial electrical
and measuring load current, low current, measurement.
voltage. inrush current, ac/dc voltage Quick, non-contact
Voltages up to and continuity. voltage detection.
CAT IV 600 V, Current measurements up Environments with
CAT III 1000 V. to 999.9 A in tight cable both ac and dc
Dark areas where compartments. (autoVolt) or ghost
voltage detection See page 24 for details. voltages.
by light, sound, and See page 10 for details.
vibration is needed.
See page 26 for details.

For more information, go to www.fluke.com 3


Fluke tools for
industrial technicians
Legend
Pumps

Drive Control

Blowers

Motors

Line

Plant Control Systems

Fluke 289 True-rms Fluke 87V Industrial True-rms Fluke 771 Milliamp Process
Logging Multimeter Multimeter w/temp Clamp Meter
Best suited for: Solving complex, Best suited for: VFD motor Best suited for: Measuring
intermittent electrical problems. drive installation and mA signals for PCL and control
troubleshooting. system analog I/O.
Features:
Highest accuracy. Features: Features:
On screen graph of Accurate frequency and Measures 4-20 mA control
logged data. voltage measurements signals without breaking
Motor drive filter. on motor drives and the loop.
LoZ eliminates ghost voltage. in electrically noisy Best in class 0.2 % accuracy.
Lo Ohms useful for testing environments. Detachable clamp.
motor windings or contact Built-in thermometer See page 31 for details.
resistance. for temperature
See page 7 for details. measurements.
See page 8 for details.

Fluke 435 Three-Phase PQ Fluke 568 Infrared Fluke Ti25 Thermal


Analyzer Thermometer Imager
Best suited for: Trouble- Best suited for: Best suited for: Quickly
shooting and preventing Measuring hot, moving, identifying and tracing
problems in power energized and hard to problems.
distribution systems. reach objects and Features:
Features: equipment. Survey IR-Fusion blended
Simultaneously measure equipment for over- thermal images for ease
voltage and current on all heating components. of interpretation.
three phases and neutral. Features: Drop-tested, water resistant.
High-resolution color screen High accuracy. High resolution and
simplifies operation. Easy interface. thermal sensitivity.
Tough enough for industrial environments, Infrared and
contact bead probe. See page 42 for details.
easy to carry, works for seven hours per
battery charge. Trending and reporting via PC .
See page 18 for details. See page 39 for details.

4 For more information, go to www.fluke.com


Fluke tools for
HVAC/IAQ technicians
Legend
Indoor Air Comfort

Superheat and Subcooling

Electrical

Motors/Pumps/Compressors

Building Diagnostics

Filtration and Ventilation

Furnace

00
0124

Fluke 975 AirMeter Fluke 922 Airflow Meter/ Fluke 116 Digital Multimeter
Micromanometer
Best suited for: Best suited for: Best suited for:
Optimizing HVAC ventilation Measuring differential and Troubleshooting HVAC
settings for ASHRAE 62 static pressure. equipment and flame
recommendations. Measuring air velocity sensors.
Simultaneously measures, and flow. Thermometer and
logs and displays tempera- Use with any pitot tube. microamps.
ture, humidity, velocity, See page 46 for details. Volts ac/dc, resistance,
CO2 and CO. diode, continuity, and
See page 46 for details. Min/Max/Avg.
See page 11 for details.

Fluke 902 True-rms Fluke 561 IR Fluke TiR/R1 Thermal Imager for
HVAC Clamp Meter Thermometer Building Diagnostics
Best suited for: HVAC Best suited for: Measuring Best suited for: Finding
system diagnosis and repair. moving or energized objects moisture problems, water
Features: and for furnace, ventilation, leaks, insulation problems,
Capacitance and true-rms. indoor air, and building heating/cooling losses
DC current to 200 A. diagnostics. in buildings.
Contact temperature. Contact and infrared. Features:
See page 25 for details. Compatible with type-K IR-Fusion blended
thermocouple. thermal images for ease
Includes Velcro pipe of interpretation.
probe. High thermal sensitivity
See page 39 for details. for moisture detection.
Drop tested, water resistant.
Large, horizontal screen.
See page 44 for details.
For more information, go to www.fluke.com 5
Pick the right digital
multimeter for you

Digital Multimeter Selection Guide

Highest True-rms and Designed Designed Waterproof


accuracy with Industrial built-in for building for HVAC/R and chemical Two powerful 4-20 mA loop
data logging troubleshooting thermometer maintenance technicians resistant tools in one diagnostics
Models 289 87V 179 117 116 27 1587 789
Basic features
True-rms readings AC+DC AC AC AC AC AC AC
Basic dc accuracy 0.025 % 0.05 % 0.09 % 0.5 % 0.5 % 0.1 % 0.09 % 0.1 %
Wide bandwidth 100 kHz 20 kHz 30 kHz
Auto/manual ranging
Digits 4-12 4-12 3-12 3-12 3-12 3-12 3-12
Counts 50000 20000 6000 6000 6000 3200 6000 4000
Measurements
Voltage ac/dc 1000 V 1000 V 1000 V 600 V 600 V 1000 V 1000 V 1000 V
Current ac/dc 10 A 10 A 10 A 10 A 600 A 10 A 400 mA 1A
Resistance 500 MW 50 MW 50 MW 40 MW 40 MW 32 MW 50 MW 40 MW
Frequency 1 MHz 200 kHz 100 kHz 50 kHz 50 kHz 100 kHz 20 kHz
Capacitance 100 mF 10 mF 10 mF 10 mF 10 mF 10 mF
Temperature +1350 C +1090 C +400 C +400 C +500 C
dB 60 dB
Conductance 50 nS 50 nS 32 nS
Duty cycle/pulse width
Motor drive measurements/low pass filter
Continuity with beeper/diode test
Low ohms (50 W)
Display
Dual display
Analog bargraph
Backlight
Data storage and exchange
Min/Max recording
Min/Max recording/with time stamp
Fast Min/Max 250 s 250 s
Display Hold/Auto (Touch) Hold
Relative reference
PC interface
Data logging with PC
Readings memories 10,000
Other features
Automatic selection, LoZ
LoZ
Insulation test range 0.01 MW to 2 GW
VoltAlert, non-contact ac voltage detector
Real-time clock
Overmolded case, integrated holster
Removable holster
ToolPak magnetic hanger compatibility
Closed case calibration
Separate battery door
Completely sealed/watertight
Automatic power off
Low battery indication
Operating temperature ranges 20 C, +55 C 20 C, +55 C 10 C, +50 C 10 C, +50 C 10 C, +50 C 40 C, +55 C 20 C, +55 C
4-20 mA/24 V loop supply
Warranty and electrical safety
Limited lifetime warranty
Warranty (years) 3 3 3 3
Input alert
Dangerous voltage indication
CAT III measurements 1000 V 1000 V 1000 V 600 V 600 V 1000 V 1000 V 1000 V
CAT IV measurements 600 V 600 V 600 V 600 V 600 V
See page 7 8 9 10 11 12 28 30

6 Digital Multimeters For more information, go to www.fluke.com/dmm


Fluke 289 and 287 True-rms
Logging Multimeters
New diagnostic functionality for Log and document
maximizing productivity

The new 289 and 287 are the next generation high
performance logging multimeters designed to solve
complex problems in electronics, plant automation, power
distribution, and electro-mechanical equipment. With the
ability to log data and review it graphically on-screen,
so you can solve problems faster and reduce downtime.
Equipped with new functionality
New Large 50,000 count, 1/4 VGA dot matrix display
with white backlight
New Logging function
with expanded memory The 289/FVF Data Logging
for unattended monitoring Multimeter and Software
of signals over time. Using Combo Pack gives you
on-board TrendCapture, a practical, affordable
users can graphically review
logged readings without approach to predictive
needing a PC. Store up to TrendCapture displays V ac maintenance.
10,000 readings over time. logged data. With built-in data logger and
New Save, name, and recall multiple logging TrendCapture capability, the 289
sessions before PC download is necessary. helps you track down elusive,
New button. On board help screens for intermittent problems, monitoring
measurement functions. Unsure about a functiongo to equipment with any of its func-
that function and press the i button. tions while you do other jobs.
New Two terminal 50 ohm range with 1 milliohm Using FlukeView Forms software
resolution, 10 mA source current. Useful for measuring allows you to overlay your logged
and comparing differences in motor winding data from six meters or six time
resistance or contact resistance (289). periods to find cause and effect
New Low Pass filter for accurate voltage and relationships or for condition
frequency measurements on adjustable speed motor monitoring.
drives and other electrically noisy equipment (289)
New LoZ Volts. Low impedance voltage function for Turn your data into meaning-
ful graphs and tables for a
eliminating ghost voltages. Also recommended when
professional report or analyze
testing for absence or presence of live power (289).
N10140 individual readings or series of
measurements.
TPAK Magnetic Meter Hanger for
Specifications 289 and 287 DMMs hands-free operation.
Features
C280 Soft Case for meter protec-
Multiple on screen displays Yes tion and accessory storage.
True-rms ac bandwidth 100 kHz
dBV/dBm Yes
DC mV resolution 1 V
Megohm range up to 500 M
Conductance 50.00 nS
Continuity beeper Yes
Elapse time clock/time of day clock Yes
Min-Max-Avg/duty cycle/pulse width Yes
Isolated optical DMM interface with USB PC connection Yes
Auto/touch hold Yes
Over 200 hours logging capacity with new sleep function Yes
Warranty Limited lifetime

Functions Range and Resolution Basic Accuracy


DC volts 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 0.025 % Included accessories
AC volts 500.00 V, 1000.0 V 0.4 % (true-rms) TL71 Silicone Test Leads, two AC72
DC current 500.00 A, 5000.0 A, 50.000 mA, 400.00 mA, 0.15 %
AC current 5.0000 A, 10.000 A 0.7 % (true-rms)
Alligator Clips, users manual on
Temperature (excluding probe) -200.0 C to 1350.0 C (-328.0 F to 2462.0 F) 1.0 % CD-ROM and getting started guide.
Resistance 50.000 , 500.00 , 5.0000 k, 50.000 k, 500.00 k, 5.0000 M, 0.05 %
50.00 M, 500.0 M Ordering information
Capacitance 1.000 nF,10.00 nF, 100.0 nF, 1.000 F, 10.00 F, 100.0 F, 1000 F, 1.0 % FLUKE-289 True-rms Industrial
10.00 mF, 100 mF
Logging Multimeter
Frequency 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz .005 %
with TrendCapture
FLUKE-289/FVF True-rms Logging
Recommended accessories 289 and 287 DMMs Multimeter Combo
Kit with
TrendCapture
FLUKE-287 True-rms
Electronics Logging
Multimeter with
TLK289 TLK287 TPAK C280 FVF-SC2
Industrial Test Lead Set Electronic Test Lead Set Magnetic Meter Hanger Soft Case FlukeView Forms Software TrendCapture
See page 53. See page 53. See page 63. See page 57.

7 For more information, go to www.fluke.com/dmm Digital Multimeters 7


Fluke 87V
Industrial Multimeter
Diagnostic functions for Fluke 87V Ex
maximum industrial productivity Intrinsically Safe
True-rms
Multimeter
The Fluke 87V has measurement functions, trouble- See page 37 for
shooting features, resolution and accuracy to solve more more information.
problems on motor drives, in-plant automation, power
distribution and electro-mechanical equipment.

Features
Unique function for accurate voltage and frequency
measurements on adjustable speed motor drives and
electrically noisy equipment (87V and 87V Ex).
Large digit display with bright two level backlight
makes the 87V significantly easier to read.
Measure 20 A for up to 30 sec, 10 A continuously.
Optional magnetic hanger for easy setup and viewing
while freeing your hands for other tasks (TPak).
Expanded capacitance range to 10,000 F.
Built-in thermometer (87V).
Electrical safety
All inputs are protected to CAT III 1000 V and CAT IV
600 V. They can withstand impulses in excess of 8,000 V
to help protect you from arc blast resulting from surges
and spikes.

Available in intrinsically safe version as the


Fluke 87V Ex.

Fluke 87V/E2 Industrial


Also available as 83V average responding Electricians Combo Kit
multimeter, see below for specifications. Make industrial troubleshooting even
more productive with accessories.
Features 87V and 83V DMMs 87V Industrial Multimeter
C35 lightweight soft case
Features 87V Ex 87V 83V to provide optimal protection
ATEX II 2G EEx ia IICT4 safety rating for use in Zone 1 and Zone 2 and storage
True-rms ac voltage and current for accurate measurements on non linear signals TL224 1.5 m silicone leads
Selectable filter for accurate voltage and frequency measurements on motor drives resist heat
0.05 % dc accuracy TP38 removable probes with
4-1/2 digit mode for precise measurements 4 mm of exposed metal for use
Built-in thermometer lets you carry one less tool on industrial circuits
Large display digits and two level bright white backlight for increased visibility AC220 retractable long reach
10,000 F capacitance range for components and motor caps alligator clips
Peak capture to record transients as fast as 250 s ToolPak meter hanging accessory
Measure up to 1000 V ac and dc to hold meter to steel surfaces
Measure up to 10 A, 20 A for up to 30 seconds 80BK-A K-type temperature probe
Auto and manual ranging for maximum flexibility
Analog bargraph
Frequency to 200 kHz and % duty cycle
Min/Max and average recording to capture variations automatically
Relative mode to remove test lead resistance from low ohms measurements Included accessories
Access door for fast battery changes without breaking the calibration seal TL75 Test Leads, AC72 Alligator
Limited lifetime warranty 1 year Clips, holster, 9 V battery (installed),
80BK-A Temperature Probe (87V
Specifications 87V and 83V DMMs only) CD-ROM (users manual and
technical notes) and operators
Basic accuracy guide.
Functions Range and resolution 87V 83V
DC volts 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.05 % 0.1 % Ordering information
AC volts 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.7 % (true-rms) 0.5 % FLUKE-87-5 Industrial True-rms
DC current 600.0 A, 6000 A, 60.00 A, 600.O mA, 6.000 A, 10.00 A 0.2 % 0.4 % Multimeter with
AC current 600.0 A, 6000 A, 60.00 A, 600.O mA, 6.000 A, 10.00 A 1.0 % (true-rms) 1.2 % Temperature
Temperature (excl. probe) -200 C to 1090 C (-328 F to 1994 F) 1.0 % FLUKE-87-5/E2 Industrial
80BK Temperature Probe -40 C to 260 C (-40 F to 500 F) 2.2 C or 2 % Electricians
Resistance 600.0 W, 6.000 kW, 60.00 kW, 600.0 kW, 6.000 MW, 50.00 MW 0.2 % 0.4 % Combo Kit
Capacitance 10.00 nF, 100.0 nF, 1.000 F, 10.00 F, 100.0 F, 9,999 F 1.0 % 1.0 % FLUKE-83-5 Industrial Multimeter
Frequency 199.99 Hz, 1.9999 kHz, 19.999 kHz, 199.99 kHz 0.005 % 0.005 % FLUKE-87V Ex Intrinsically Safe
Battery life: 400 hours typical with backlight off. Size (LxWxD): 201 mm x 98 mm x 52 mm (7.9 in x 3.8 in x 2 in). True-rms Multimeter
Weight: 355 g (22 oz).

8 Digital Multimeters For more information, go to www.fluke.com/dmm


Fluke 179 Digital
Multimeter
Versatile meters for maintenance
and field service

The 179 True-rms Multimeter has the features needed


to find most electrical and HVAC problems. Simple
to use with significant improvements over the original
Fluke 70 Series, the 179 has more measurement func-
tions, conformance to the latest safety standards and a
much larger display thats easier to view.

Features
Wide 1000 V measurement range. 179/EDA2 Electronics
True-rms for precise measurement of non Multimeter and Deluxe
linear signals. Accessory Combo Kit
Capacitance, resistance, continuity and frequency. 179 True-rms Digital Multimeter
Built-in thermometer (Fluke 179 only). C35 lightweight soft case to provide
Large, easy-to-read display optimal protection and storage
Backlight for work in dimly lit a.reas TL910 Electronic Test Probes
(Fluke 177 and179 only). TL224 SureGrip Silicone Test Leads
Min/Max/Avg to record signal fluctuations. resist heat
Free your hands with the optional TPAK magnetic AC280 SureGrip Heavy Duty
hanger (Fluke TPAK). Hook Clips
80BK-A Type-K Temperature Probe
Electrical safety ToolPak meter hanging accessory
All inputs are protected to measurement CAT III 1000 V to hold meter to steel surfaces
and CAT IV 600 V. This meter can withstand transient
impulses in excess of 8000 V to help protect you from
arc blasts resulting from surges and spikes.

Features 175, 177 and 179 DMMs


Features 179 177 175
Max voltage 1000 1000 1000
True-rms
Temperature
179/1AC-II Electricians
Basic dc accuracy 0.09 % 0.09 % 0.15 % Multimeter and Voltage
Backlight Tester Combo Kit
Min/Max/Avg 179 True-rms Digital Multimeter
ToolPak meter hanging kit with magnet Opt Opt Opt 1AC-II VoltAlert Non-Contact
Limited lifetime warranty Voltage Detector
C35 lightweight soft case to provide
Specifications 179, 177 and 175 DMMs optimal protection and storage
AC220 retractable long reach
Functions Range and resolution Best accuracy alligator clips
DC voltage 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.09 % (Models 177 and 179) TP220 sharp 12 mm stainless steel
0.15 % (Model 175)
tip provides reliable contact
AC voltage1 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V
60.00 mA, 400.0 mA, 6.000 A, 10.00 A2
1.0 % of reading
TL224 1.5 m silicone leads resist heat
DC current
AC current2 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2
1.0 % of reading
1.5 % of reading
ToolPak meter hanging accessory
Resistance 600.0 W, 6.000 kW, 60.00 kW, 600.0 kW, 6.000 MW, 50.00 MW 0.9 % of reading
to hold meter to steel surfaces
Capacitance 1000 nF, 10.00 F, 100.0 F, 9999 F 1.2 % of reading
80BK-A K-type temperature probe
Frequency3 99.99 Hz, 999.9 Hz, 9.999 Hz, 99.99 kHz 0.1 % of reading
Temperature (Model 179) -40 C to +400 C (-40 F to +752 F) 1.0 % of reading
1All ac voltage and ac current ranges are specified from 5 % of range to 100 % of range. Included accessories
210 A continuous, 20 A for up to 30 seconds.
3Voltage frequency is specified from 2 Hz to 100 kHz. Current Frequency is specified from
TL75 test leads, 9 V battery
2 Hz to 30 kHz.
Battery life: 200 hours typical for alkaline. Size (HxWxL): 4.3 cm x 9.0 cm x 18.5 cm (1.7 in x 3.5 in x 7.3 in). (installed) and manual. The Fluke
179 comes with an additional
80BK-A Temperature Probe.
Recommended accessories 179, 177 and 175 DMMs
Ordering information
FLUKE-179 Digital Multimeter
FLUKE-179/1AC-II Electricians
Combo Kit
FLUKE-179/EDA2 Electronics
L210 TL220 C510 PV350 i400s
Probe Extender SureGrip Industrial Carrying Case Pressure-Vacuum AC Current Clamp
Combo Kit
with light Test Lead Set See page 62. Module See page 58. FLUKE-175 Digital Multimeter
See page 56. See page 53. See page 57.
FLUKE-177 Digital Multimeter

9 For more information, go to www.fluke.com/dmm Digital Multimeters 9


Fluke 117 and 115 True-rms
Digital Multimeters
Designed for commercial electricians Fluke 117 Digital Multimeter
and field service technicians drives the ghosts out of
the attic (and the electric circuits)
Ghost voltages occur when
Fluke 117 energized circuits and non-energized
The Fluke 117 is the ideal meter for demanding settings wiring are located close to each
like commercial buildings, hospitals and schools. The 117 other, such as in the same conduit.
includes integrated non-contact voltage detection to help This condition
get the job done faster. allows
capacitive
Features
coupling
VoltAlert Technology for integrated non-contact between the
voltage detection.
wiring to
AutoVolt feature for automatic ac/dc voltage selection. occur. When
LoZ: Low input impedance prevents false readings due you place your
to ghost voltage.
multimeter
Large display and white LED backlight to work in leads between
poorly lit areas more effectively.
the open
Compact design for one-handed operation. circuit and the
Min/Max/Average to record signal fluctuations. neutral, you
Compatible with optional magnetic hanger (ToolPak) complete the
for hands free operation.
circuit and
Current measurement 20 A (30 seconds momentary; your meter will measure coupled
10 A continuous).
voltage that isnt really there.
Resistance, continuity, frequency and capacitance.
For more information,
Fluke 115 download this application note at
The new Fluke 115 is the solution for a www.fluke.com/FN-117
wide variety of electrical and electronic
testing applications.
Features
Large display and white LED backlight to
work in poorly lit areas more effectively.
Compact ergonomic design for
one-handed operation.
Min/Max/Average to record signal
fluctuations.
Resistance, continuity, frequency and capacitance.

Features 117 and 115 DMMs


Features 117 115
VoltAlert
AutoVolt/LoZ
Analog bargraph
Large backlit digital display
117/322 Electricians
True-rms for accurate measurements on non-linear loads Combo Kit
Min/Max recording 117 True-rms digital multimeter with
Display hold non-contact voltage detection
3-12 digits C115 Deluxe carrying case with
6000 counts shoulder strap
CAT III 600 V safety rated 322 Compact clamp meter
Three-year warranty TL75 Hard Point Test Lead Set
ToolPak Magnetic Meter Hanging Strap
Three-year warranty on 117 DMM
Specifications 117 and 115 DMMs Two-year warranty on 322 Clamp
One-year warranty on accessories
Functions Range and resolution Best accuracy
Volts ac/dc 600 V 0.5 % + 2
Current ac/dc 10 A 1.0 % + 3
Resistance 40 MW 0.9 % + 2
Capacitance 1 nF to 9,999 F 1.9 % + 2 Included accessories
Frequency 5 Hz to 50 kHz 0.1 % + 2 TL75 Test leads, holster, users
Diode 2V 0.9 % + 2 manual and 9 V battery (installed).

Recommended accessories 117 and 115 DMMs Ordering information


FLUKE-117 Multimeter with
Non-Contact Voltage
FLUKE-117/322 Electricians
Combo Kit
FLUKE-115 Multimeter
ToolPak TL220 C50 LVD2
Meter Hanger SureGrip Industrial Test Lead Set Carrying Case Volt Light
See page 63. See page 53. See page 62. See page 56.

10 Digital Multimeters For more information, go to www.fluke.com/dmm


Fluke 116 and 114
Digital Multimeters
Designed for HVAC/R technicians
and electrical troubleshooting

Fluke 116
The Fluke 116 was specifically designed for the HVAC
professional. It has everything needed in an HVAC meter
including temperature and microamp measurements to
quickly troubleshoot problems with HVAC equipment and
flame sensors.
Features
Built in thermometer for HVAC applications.
Microamps to test flame sensors. 116/322 HVAC Combo Kit
Min/Max/Average to record signal fluctuations. Fluke 116 HVAC Multimeter with
Large white LED backlight to work in poorly lit areas. Temperature and Microamps
Compact ergonomic design for one-handed operation. Fluke 322 Compact Clamp Meter
Compatible with optional magnetic hanger (ToolPak). TL75 Hard Point Test Lead Set
Resistance, continuity, frequency and capacitance. ToolPak Magnetic Meter Hanger
C115 Deluxe Carrying Case with
Fluke 114 shoulder strap
The new Fluke 114 is the troubleshooting tool for go/ 80PK-11 Velcro Pipe Clamp
no-go testing. It includes a feature to prevent false Thermocouple
readings caused by ghost voltage. 80AK-A Thermocouple Adapter
Features 80PK-1 Thermocouple Bead Probe
AutoVolt: Automatic ac/dc voltage
selection.
LoZ: Helps prevent false readings due to
ghost voltage.
Large white LED backlight to work in
poorly lit areas.
Compact ergonomic design for
one-handed operation.
Resistance, continuity, frequency and
capacitance.
Min/Max/Average to record signal fluctuations.

Features 116 and 114 DMMs


Features 116 114 116/62 HVAC Combo Kit
Temperature measurements Fluke 116 HVAC Multimeter with
AutoVolt/LoZ Temperature and Microamps
Analog bargraph Fluke 62 Infrared Thermometer
Large backlit digital display TL75 Hard Point Test Lead Set
True-rms for accurate measurements on non-linear loads ToolPak Magnetic Meter
Min/Max recording Hanging Strap
Display hold C115 Deluxe carrying case with
3-12 digits shoulder strap
6000 counts 80PK-11 Pipe Wrap Thermocouple
CAT III 600 V safety rated Fluke 80AK-A Thermocouple Adapter
Three-year warranty Fluke 80BK-A K-Type Integrated
Temperature Probe
Specifications 116 and 114 DMMs Three-year warranty on 116 DMM
Two-year warranty on 62 IR Therm
One-year warranty on accessories
Functions Range and resolution Best accuracy
Volts ac/dc 600 V 0.5 % + 2
Current ac/dc (116 only) 600.0 A 1.0 % + 2
Temperature (116 only) +400 C 1.0 % + 18
Resistance 40 MW 0.9 % + 2 Included accessories
Capacitance (116 only) 1 nF to 9,999 F 1.9 % + 2 TL75 Test Leads, 80BK Integrated
Frequency (116 only) 5 Hz to 50 kHz 0.1 % + 2 Temperature Probe (116 only),
Diode (116 only) 2V 0.9 % + 2 holster, users manual and 9 V
battery (installed).
Recommended accessories 116 Digital Multimeter Ordering information
FLUKE-116 HVAC Multimeter
with Temperature
and Microamps
FLUKE-116/62 HVAC Combo Kit
80AK-A 80PK-24 80PK-8 80BK-A FLUKE-116/322 HVAC Combo Kit
DMM Adapter SureGrip Air Temperature Probe Pipe Clamp Temperature Probe Integrated DMM Temperature Probe FLUKE-114 Electrical Multimeter
See page 61. See page 60. See page 60. ships with 116
See page 61.

For more information, go to www.fluke.com/dmm Digital Multimeters 11


Fluke 77 IV
Digital Multimeter
Versatile meters for field service Fluke 27 Waterproof
or bench repair Multimeter
Completely
sealed for extreme
The new 77 IV Digital Multimeter has the features needed conditions
to repair most electrical and electronic problems. This Designed for U.S.
meter is simple to use and has significant improvements military, mining and
over Flukes original 70 Series with more measurement other extreme appli-
functions, conformance to the latest safety standards, and cations. A special
a much larger display thats easier to view. case with o-rings
Measures prevents water from
Wide 1000 V measurement range entering the input
Average responding ac measurements jacks, switches and
0.3 % accuracy fuse door. Meets
10 Amps continuous military specifica-
Frequency and capacitance tions for vibration,
Resistance and continuity shock and water
Features resistance.
Large display Waterproof design
Backlight for work in dim areas with rugged, o-ring
Min/Max to record signal fluctuations sealer case protects
Integral holster with probe holders rotary switch, input
Free your hands with the optional TPAK magnetic jacks, battery and
hanger fuse door.
Auto and Manual ranging Operates from -15 C
to +55 C (5 F to 131 F) and
Made 95 % relative humidity.
in the
3200-count digital display for
U.S.A. accuracy and resolution.
31-segment analog bar graph for
fast peaking, nulling zero adjust-
ments and capacitor checking.
Fast auto ranging and manual
ranging.
TouchHold function captures and
Features 77 IV Digital Multimeter locks the measurement and auto-
matically updates with the next
Features Old 77 New 77-IV Benefit measurement.
Accuracy 0.3 % 0.3 % Same great accuracy Conductance for high resistance
True-rms No No Same familiar readings
measurement.
Frequency No Yes Built-in frequency counter
Min/Max and Relative modes.
Capacitance
Maximum ac voltage
No
750
Yes
1000
Test components
Wider measurement range
Conforms to IC 1010-1 CAT III.
Min/Max/Average No Yes Capture transients automatically
MSHA approved.
Display backlight No Yes Usable in dim areas
Limited lifetime warranty,
Battery door No Yes Fast battery changes one-year calibration.
Probe holders No Yes One-hand operation
Overvoltage category safety rating Not rated 600 V CAT IV Higher level of protection
Optional magnet hanger No Yes Position meter in best location
Limited lifetime warranty No Yes Reliability

Specifications 77 IV Digital Multimeter


Functions Range Best accuracy Best resolution
V dc 600.0 mV to 1000 V (0.3 % + 1) 0.1 mV
V ac 6.000 V to 1000 V (2.0 % + 2) 1.0 mV
A dc 60.00 mA to 10 A (1.5 % + 2) 0.01mA
A ac 60.00 mA to 10 A (2.5 % + 2) 0.01 mA
Resistance 600.0 to 50 M (0.5 % + 1) 0.1
Capacitance 1 nF to 9,999 F (1.2 % + 2) 1 nF
Frequency 99.99 Hz to 99.99 kHz (0.1 % + 1) 0.01 Hz Included accessories
Fluke 77 IV: TL75 test leads, 9 V
battery (installed) and users manual.
Recommended accessories 77 IV Digital Multimeter Fluke 27: TL75 test leads, alliga-
tor clips, 9 V battery (installed) and
users manual.

Ordering information
FLUKE-77-4 Digital Multimeter
i400s C35 ToolPak TL225 TLK-225 FLUKE-27 Multimeter
AC Current Clamp Meter Case Meter Hanger SureGrip Stray Voltage SureGrip Master
See page 58. See page 63. Adapter Test Lead Kit Accessory Kit
See page 53.

12 Digital Multimeters For more information, go to www.fluke.com/dmm


Complete automotive
diagnostic tools
Tools designed to help Beat the book
you beat the book This amazing reference covers test
procedures commonly used by
experienced automotive technicians.
Covers basic troubleshooting
Fluke 88V Automotive Multimeter techniques and measurements using
The Fluke 88V Automotive Multimeter is designed
a DMM and
to help automotive professionals beat the book.
describes
This DMM has more measurement functions, trou- Beat the Book
tests for the
bleshooting features and accuracy to solve virtually
Automotive electrical diagnosis.
Better diagnosis, faster repair.

charging Application Note

any problems on conventional and hybrid vehicles. Work safely

system,
This application note is intended
as a guide for the professional

Features
mechanic. It describes some of
the test procedures commonly
used by experienced technicians.

starting
However, some of the procedures
require you to take certain pre-

Automotive test functions include dc and ac volt-


cautions to avoid personal injury
and/or damage to equipment or
vehicles. Fluke cannot anticipate

system, fuel
all possible precautions that you
must take on all the different
vehicles for which this guide is

age, resistance and current.


applicable. For this reason, you
should thoroughly familiarize
yourself with proper safety

and air system,


habits and take all precautions
described in the vehicles

Min/Max recording for logging the highest and


repair manuals to avoid injury
or damage.

Testing automotive

ignition
systems with an
analog/digital multimeter

lowest readings over time.


Perhaps the most important tool
youll use in troubleshooting auto
electrical systems is the multime-

system, and
ter. The basic multimeter
measures voltage, current and

Frequency measurements for magnetic sensors


resistance, while more elaborate
multimeters, such as the new
Fluke 88-V, have features that

the body
can check things such as
frequency, duty cycle, pulse
width, make diode tests, and

and ac/dc frequency signals.


even measure temperature. Although automotive multime- The common analog type mul-
In this application note you ters with various capabilities timeter is not only inadequate, it
will find troubleshooting tech- have been around for years, can damage delicate computer

electric/engine
niques using the high quality, many of them didnt have the circuitry. Both analog meters and
affordable and popular line of scales and functions required for test lights, due to their low inter-

Duty Cycle for variable duty cycle signals with


Fluke analog/digital multimeters todays automotive applications. nal resistance (input impedance),
and automotive troubleshooting Hybrid, electric and fuel cell draw too much power from the
accessories. Flukes analog/ powered vehicles have special device theyre testing to be used
digital combination has distinct requirements, ones met with the on computers. Whats more,

management/
advantages over either digital new 88-V. Now that computers many analog meters use 9V to
or analog meters alone, and and their sensors are a part of power the resistance test, which
the accessories are designed to everyday automobile trou- is enough to destroy sensitive

selectable trigger slope and level.


make your job easier and more bleshooting, you need a true digital components.
profitable. multimeter to do the job.

cooling system.
Pulse width for fuel injector on time
From the Fluke Digital Library @ www.fluke.com/library

measurements . Download this application note at


Conductance testing for secondary ignition coils. www.fluke.com/beat-the-book
RPM measurements for DIS and conventional
ignition systems.
Built-in thermometer.

Features 88V DMM


Features 88V For the complete diagnostics
Digital display with analog bargraph
Continuity for detecting opens and shorts
package and maximum value,
Diode test for alternator testing pick up the 88V/A combo kit.
Peak Min/Max captures intermittents as fast as 250 microseconds Includes Fluke 88V Automotive
Min/Max average to monitor trends in oxygen sensor values for fuel trim Multimeter
Pulse width for fuel injector on time measurements TL224 Heat Resistant Silicone
Milliamp ranges to find low current parasitic drains Test Leads
Lo-Ohms (.01 W) for low resistance sensor and coil measurements TP220 Removable Sharp Point
Duty cycle for pulse width modulated signals Test Probes
RPM for ignition systems AC285 Large Jaw Alligator Clips
Temperature for coolant and air temperature sensors TPAK Magnetic Hanger
Limited lifetime warranty 80BK-A Temperature Probe
RPM80 Inductive Pick-up
Automotive Backprobe Pins
Insulation Piercing Probe
Buy accessory kits and save
Packaged in a durable carrying case
(C800)

TLK281 TLK282 TL28A TL82


Automotive Test Lead Kit Deluxe Automotive Test Lead Kit Automotive Test Lead Set Automotive Pin & Socket Adapter Set Included accessories
See page 55. See page 55. See page 54. See page 55.
Test leads, 9 V battery (installed),
RPM pickup, carrying case and
Recommended automotive accessories 88V DMM users manual.

Ordering information
FLUKE-88-5 Automotive
Multimeter
FLUKE-88-5/A KIT Automotive
TP81 or TP82 TP84 TP88 TP40 Multimeter
Insulation Oxygen Sensor Insulation Rigid Backprobe Automotive Back
Piercing Probes Piercing Probe Pin Set Probe Pin Set Combo Kit
See page 55. See page 55. See page 55. See page 55.

13 For more information, go to www.fluke.com/dmm Digital Multimeters 13


Fluke 8845A and 8846A
6.5 Digit Precision Multimeters
Precision and versatility for Understanding specifications
bench or systems applications for precision multimeters
A solid understanding of
specifications
The Fluke 8845A and 8846A 6.5 digit precision is critical
multimeters have the precision and versatility to when youre 5NDERSTANDINGSPECIlCATIONS
FORPRECISIONMULTIMETERS

handle your most demanding measurements on the evaluating the


!PPLICATION.OTE

bench or in a system. suitability of


$IGITALMULTIMETERSARETHEWORKHORSESOFTHE
ELECTRONICSINDUSTRY!LMOSTALLOFTHEELECTRONIC
PRODUCTSWEUSEINOURPERSONALANDPROFESSIONAL
LIVESAREBUILTORSERVICEDUSINGMULTIMETERS

Dual display offers versatile graphical


$IFFERENT$--APPLICATIONSREQUIREDIFFER

DMMs for an
ENTDEGREESOFATTENTIONTOSPECS!TECHNICIAN
CHECKINGALOGICPOWERSUPPLYCANUSEHISTRUSTY
BENCH$--CONlDENTLYTOVERIFYTHATTHESUPPLY
ISWITHINAFEWPERCENTOF6(OWEVER WHEN

capabilities: The 8845A and 8846A feature a unique


THEJOBREQUIRESTESTINGCRITICALCIRCUITS CHECKING

application,
PRECISIONCOMPONENTS MAKINGlNEADJUSTMENTS
INPRODUCTION VERIFYINGCOMPLIANCEWITHINDUSTRY
STANDARDS ORTAKINGMEASUREMENTSOUTSIDETHE
CONTROLLEDENVIRONMENTOFTHELAB THENYOULLNEED

graphical display that can reveal signal quality


TOEVALUATESPECIlCATIONSCAREFULLY

or when
!SOLIDUNDERSTANDINGOFSPECIlCATIONSISCRITICAL
WHENYOUREEVALUATINGTHESUITABILITYOF$--S
FORANAPPLICATION ORWHENYOUMUSTBECONlDENT
THATYOURREADINGSACCURATELYREmECTREALITY4HIS

issues like drift, intermittent and stability by viewing


APPLICATIONNOTEDISCUSSESSOMEOFTHETHINKING

you must be
BEHIND$--SPECIlCATIONSANDSPECSHEETS)T
DElNESTHEVARIOUSELEMENTSOF$--SPECSAND
GIVESTIPSONHOWTOAPPLYTHEM

the measurement data as a real time TrendPlot, 3PECIlCATIONSANDTHE &ROMTHISFORMALDElNITIONWE MUSTSTANDlRMLYBEHINDTHEIR

confident that
SPECSHEET CANDRAWTHECHARACTERISTICSOF SPECSANDYOUSHOULDFULLYEXPECT
GOODSPECIlCATIONS THATTHEINFORMATIONYOUARE
7HENEVERWETAKEAMEASURE
MENTWITHANYMETER WERE
s #OMPLETENESSnANYFACTOR GETTINGISACCURATEANDCOMPLETE
THATIMPACTSUNCERTAINTYIS /NTHESPECSHEET YOUSHOULD

Histogram or Statistics using the unique analyze


GAMBLING7EREGAMBLINGTHAT COVERED INCLUDINGOPERAT SEEMEASUREMENTUNCERTAINTY
THEINSTRUMENTISGOINGTOGIVEUS

your readings
INGLIMITSSUCHASHUMIDITY SPECSANDMODIlERSTHATAFFECT
THEhREALvREADING&ORTUNATELY ALTITUDE ORVIBRATION THEUNCERTAINTY9OUWILLALSOSEE
ITSAVERYSAFEBETTHATAQUALITY
MULTIMETERWILLDELIVERREADINGS
s #LARITYnALLEFFORTSSHOULDBE OPERATINGLIMITSTHATCONSTRAIN
MADETOMAKETHESPECIlCA THEENVIRONMENTINWHICHTHE
THATCOINCIDEWITHREALITY3PECIl TIONSSTRAIGHTFORWARD UNCERTAINTYSPECIlCATIONSWILL

mode.
CATIONSQUANTIFYTHECONlDENCEOF /BJECTIVITYnDOESNOTATTEMPT
s HOLDTRUE4HESEARESTATEDIN

accurately
GETTINGACCURATEREADINGSANDTHE TOMISLEADFORTHESAKEOF NUMERICALVALUESEGHUMIDITY
RISKOFSEEINGINACCURATEREADINGS PROMOTION ORWITHREFERENCETOINTERNATIONAL
!SPECIlCATIONSDOCUMENTIS STANDARDSSHOCKANDVIBRATION 
ACLEARLYWRITTENDESCRIPTIONOF !WELL WRITTENSPECIlCATION

Fluke 8845A
SHOULDMAINTAINTHESAMELEVEL &IRSTLETSTAKEACLOSERLOOKAT
ANINSTRUMENTSPERFORMANCE

Wide measurement ranges: Resistance or


OFINTEGRITYASAMEDICALCHARTOR HOWWEQUANTIFYMEASUREMENT
)TSHOULDQUANTIFYANINSTRU UNCERTAINTY

reflect
MENTSCAPABILITIESOBJECTIVELY BANKSTATEMENT-ANUFACTURERS
UNDERWELL DElNEDOPERATING
CONDITIONS

current has been extended to cover the widest range reality. This
 i  i } >  L > J v i V L >

possible. application
Perform 4-wire measurements easily with note discusses some of the thinking
two leads: Patented split terminal jacks for 2x4 behind DMM specifications and
ohms function allow you to perform precise 4-wire spec sheets. It defines the various
measurements with only two leads instead of four. elements of DMM specs and gives
Optional Kelvin leads accessories are available to tips on how to apply them.
enable you to establish a 4-wire connection even in
tight spaces. Download this application note at
Systems capabilities: Both instruments include www.fluke.com/FN-accuracy.
an RS-232, IEEE-488 and Ethernet interface as
standard, with popular DMM emulation modes that
Fluke 8846A make systems integration a simple task.
Software: Transfer data points from your meter to
your PC with the free copy of FlukeView Forms Basic.
To customize your forms, upgrade with FVF-UG.

Features 8845A and 8846A Use the built-in TrendPlot paperless chart recorder
to graphically identify the extent of drift and inter-
mittent events in analog circuits.
Features 8845A 8846A
Dual VFD dot matrix display
6.5 digit resolution
Continuity/diode test
Statistics, Histogram, TrendPlot, Limit Test analytical functions
Zero, Min/Max/Average, Std Dev; mx +b, dB/dBm math functions
USB memory drive port
View results in Histogram mode to reveal stability
Real-time clock
or noise problems in analog circuits.
RS-232, IEEE-488.2, Ethernet, USB (with optional adapter)
SCPI (IEEE-488.2), Agilent 34401A, Fluke 45 programming languages/emulation modes
Complies with IEC 61010-2000-1, ANSI/ISA-S82.01-1994, CAN/CSA-C22.2 No. 61010.1, 1000 V CAT 8/
600 V CAT II
One-year warranty

Specifications 8845A and 8846A


Handle even the most demanding measurements
8845A 8846A with high accuracy and 6.5 digit resolution.
Functions* Range Resolution Accuracy* (%) Range Resolution Accuracy* (%)
Voltage dc 1000 V 100 nV 0.0035 1000 V 100 nV 0.0024
Voltage ac (freq. 300 Hz) 750 V 100 nV 0.06 1000 V 100 nV 0.06
Resistance (2x4 wire) 100 M 100 0.01 1 G 10 0.01
Current dc 10 A 100 pA 0.05 10 A 100 pA 0.05
Current ac (freq. 3 Hz to 10 kHz) 10 A 1 A 0.10 10 A 10 nA 0.10
Freq/period 300 kHz 1 Hz 0.01 1 MHz 1 Hz 0.01
Capacitance 1 nF to 0.1 F 1 pF 1
Temperature RTD -200 C to
+600 C
0.001 0.06 Included accessories
*Accuracy = (% of reading) LCI Line Power Cord, TL71 Test
Size (HxWxD): 88 mm x 217 mm x 297 mm (3.45 in x 8.54 in x 11.69 in) Weight:3.6 kg (7.9 lb) Lead Set, Spare Line Power Fuse,
programmers manual/users manual
on CD-ROM, FVF-BASIC FlukeView
Recommended accessories 8845A and 8846A Precision Multimeters
Forms Software Basic Version.

Ordering information
FLUKE-8845A 6.5 Digit Precision
Multimeter, 35 ppm
TL2X4W-PTII 884X-512M FVF-UG FLUKE-8846A 6.5 Digit Precision
2x4 Wire Ohms Test Lead USB Memory 512M FlukeView Forms Multimeter, 24 ppm
2 mm probe tip Software Upgrade
USB memory

14 Digital Multimeters For more information, go to www.fluke.com/884X


Fluke 8808A
5.5 Digit Multimeter
Versatile multimeter for manufacturing, New multimeters tackle
development and service applications challenges across the
manufacturing floor
When engineers
5.5 digit resolution and technicians
Dual display talk about
Measures V dc/ac, I dc/ac, W, frequency, diagnostic
continuity, diode test tools used in a
Basic V dc accuracy of up to 0.015 % manufacturing
Min, Max, Rel, dB, dBm environment,
2x4 wire ohms measurement technique they really
Dedicated dc leakage current ranges ought to
Six dedicated buttons for fast access to instrument define which
setups of the distinct
Hi/Lo limit compare for Pass/Fail testing manufacturing
RS-232 interface environments
theyre
considering.
The Fluke 8808A 5.5 digit multimeter. Simply set up the meter for a common Download this application note at
Manufacturing test, R&D, development and measurement, then press shift followed www.fluke.com/FN-8808.
service applications demand performance by a setup button (S1 to S6) to save the
and flexibility from a bench meter. The setup. Now each time you perform that
Fluke 8808A delivers a wide variety of measurement, you simply press the
measurement functions, including volts, appropriate setup key. Its that easy!
ohms, and amps, plus frequencyall at Operators no longer need to press multiple
superior accuracy and resolution with a buttons to make a measurement.
basic V dc accuracy of 0.015 %. Eliminate production mistakes.
Measure sensitive leakage current. Whether you are performing functional tests
Using a typical multimeter to perform a or making critical measurements on test
sensitive low current measurement of less points, using the Limit Compare mode with
than 100 mA can load the circuit under pass/fail indicators eliminates mistakes,
test while the measurement is made. especially those where results are on the
This makes it difficult, if not impossible, edge. The 8808A display has built-in
to perform tasks such as determining the enunciators that clearly show whether a
The Fluke 8808A includes two high impedance low
leakage current on a battery-powered test passes or fails. The pass/fail indicators current ranges for measuring sensitive leakage currents.
device while it is powered down. The Fluke take the guesswork out of testing: The
8808A is the only multimeter in its class result is either within limits or its out!
to use a high impedance input amplifier Perform 4-wire measurements with
technique to perform this type of critical only two leads. Patented split terminal
leakage current measurement. In this jacks for 2x4 ohms function allow you
special mode, the 8808A can measure small to perform precise 4-wire low ohms
currents with a resolution of up to 100 nA, measurements with only two leads instead
without loading the circuit under test. of four. Optional test lead accessories are
Perform routine manufacturing available to enable you to establish a
Use setup keys (S1-S6) for fast access to repetitive
functional tests with consistency. Six 4-wire connection even in tight spaces or measurements. Setups can include Limit Compare mode
setup buttons on the 8808A front panel on surface mount devices. with pass/fail indicators.
operate like a car radios station presets.

Features 8808A Multimeter


Features 8808A
Display Dual
Resolution (Digits) 5.5
Measurements V ac, V dc, I dc, I ac, W, continuity, diode test
Basic V dc accuracy (% reading + % range) 0.015 + 0.003
Advanced measurements 2X4 wire ohms, Freq, i-Leakage
Maths dBm, dB, Min, Max
Analysis Limit compare
Included accessories
RS-232 interface Yes
TL71 Test Leads, line cord, spare
Safety rating CAT I 1000 V, CAT II 600 V
line fuse, Statement of Calibration
Warranty One-year
Practices, WEEE information sheet,
Warranty statement, Getting Started
guide, and CD-ROM with users
manual.
Recommended accessories 8808A Multimeter
Ordering information
FLUKE-8808A 5.5 Digit
Multimeter
FLUKE-8808A/SU 5.5 Digit
Multimeter SW
TL2X4W-PTII 884X-512M FVF-UG
2x4 Wire Ohms Test Lead USB Memory 512M FlukeView Forms
USB Cable Kit
2 mm probe tip Software Upgrade

For more information, go to www.fluke.com/884X Digital Multimeters 15


Fluke 1625 and 1623
Geo Earth Ground Testers
Advanced technology for all your earth EarthGround Resistance:
ground testing applications Principles, testing methods
and applications
The new Fluke 1620 Series Earth Ground This brochure
Testers not only measure ground resistance is a highly Principles,

using the classic fall of potential test informative testing methods


and applications

but also enable time saving testing using collection of


the selective and stakeless methods information Diagnose intermittent

about earth
electrical problems

(1623/1625 only). Selective testing does


not require the electrode under test to be ground sys- Avoid unnecessary
downtime

disconnected during the measurement, thus tems,


testing
Learn earth ground

increasing safety. The simple stakeless


safety principles

method quickly checks ground connections methods and


using two current transformers (probes) applications.
clamped around the ground conductor Download this Earth Ground

under test. Offering one-button simplicity, application


Resistance

Fluke 1623 the 1623 is an all-in-one earth ground note at


tester, while the 1625 has extra versatility www.fluke.com/earthground_app1.
for more demanding applications.
Earth ground resistance and soil
resistivity should be measured when:
Designing earth ground systems. Fluke9040 Rotary Field
Installing new ground system and Indicator
electrical equipment. The Fluke 9040 is
Periodically testing ground and lightning a premium phase
protection systems. rotation tester with
Installing large electrical equipment a CAT III, 600 V rat-
such as transformers, switchgears, ing. The frequency
machines, etc. range is from 15 Hz to
400 Hz for demanding
The 1623 is perfect for performing applications. The clear
predictive maintenance checks of liquid crystal display
Fluke 1625
commercial and industrial applications. and the holster make
The 1625 is intended for electrical utility or it suitable for rough
other high frequency environments. outdoor applications. This instrument
is supplied with three unique, expand-
able test probes which fit most sockets.
Comes with a two-year warranty.
Features 1625/1623/1621 Testers
For more information, visit
Features 1625 1623 1621 www.fluke.com/9040
One-button measurement concept
3-pole earth ground measurement
4-pole earth ground measurement
Included accessories
4-pole soil resistivity testing
2-pole resistance measurement ac
Fluke 1625: 2 test leads,
2-and 4-pole resistance measurement dc
2 alligator clips, and users manual.
Selective testing, no disconnection of ground conductor (1 clamp) Fluke 1625 Kit: Same as above
Stakeless testing, quick ground loop testing (2 clamps) plus stake/reel set 4-pole, selective/
Measuring frequency 128 Hz stakeless clamp set, and rugged
Earth impedance measurement at 55 Hz carrying case.
Automatic frequency control (AFC), 94 Hz to 128 Hz Fluke 1623: 2 test leads,
Measuring voltage switchable 20 V/48 V 2 alligator clips, and users manual.
Programmable limits, settings
Fluke 1623 Kit: Same as above
Continuity with buzzer
plus stake/reel set 4-pole, selective/
Dust/water resistance IP56 IP56 IP40
stakeless clamp set, and rugged
Safety rating CAT II 300 V CAT II 300 V CAT II 600 V
carrying case.
Two-year warranty

Battery type: 1623/1625: 6 x AA alkaline cells; 1621: 9 V (LR61) alkaline. Ordering information
Size (HxWxD): 1623/1625: 110 mm x 180 mm x 240 mm (4.33 in x 7.08 in x 9.45 in); FLUKE-1625 Advanced GEO
1621: 113 mm x 54 mm x 216 mm (4.5 in x 2.1 in x 8.5 in).
Weight (including batteries): 1623: 1.1 kg (2.42 lb); 1625: 1.5 kg (3.31 lb); 1621: 0.86 kg (1.9 lb). Earth Ground Tester
FLUKE-1625 Kit Advanced GEO
Earth Ground
Recommended accessories 1625 and 1623 Earth Ground Testers Tester Kit
FLUKE-1623 Basic GEO Earth
Ground Tester
FLUKE-1623 Kit Basic GEO Earth
Ground Tester Kit
EI-1623 EI-1625 ES-162P3 ES-162P4
FLUKE-9040 Rotary Field
Selective/stakeless Selective/stakeless Stake/reel set Stake/reel set Indicator
clamp set clamp set for 3-pole for 4-pole
for 1623 for 1625 measurements measurements These products are for unpowered
installations measuring grounding
connections.

16 Earth Ground Testers For more information, go to www.fluke.com/egt


Fluke 1630 Earth
Ground Clamp Meter
Measure earth ground loop resistance What is grounding, and
anywhere. Quickly and easily. what does it do?
The NEC, National Electrical Code,
defines a ground as a conducting
The Fluke 1630 Earth Ground Clamp Meter is able to measure connection, whether intentional or
ground loop resistancesusing the Stakeless testing method. accidental between an electrical
This test technique eliminates the dangerous, and time circuit or equipment and the earth, or
consuming activity, of disconnecting parallel grounds, as to some conducting body that serves
well as the process of finding suitable locations for auxiliary in place of the earth.
ground stakes. You can also perform earth ground tests in When talking about grounding,
places you have not considered before: inside buildings, on it is actually two different subjects,
power pylons or anywhere you dont have access to soil. earth grounding and equipment
With the stakeless testing method, the Fluke 1630 Earth grounding. Earth grounding is an
Ground Clamp Meter is placed around the earth ground rod intentional connection from a circuit
or the connecting cable. No earth ground stakes are used conductor, usually the neutral, to a
at all. A known voltage is induced by one half of the clamp ground electrode placed in the earth.
and the current is measured by the other half. The tester Equipment grounding is to ensure
automatically determines the ground loop resistance at this that operating equipment within a
grounding connection. Gone are the days of spending time structure is properly grounded.
placing and connecting stakes for each earth ground rod on These two grounding systems
your systema major time saver. are required to be separate except
Quick and easy useno earth ground stakes are for a connection between the two
necessary. systems to prevent differences in
Large, 35 mm (1.35 in) jaw opening. potential from a possible flashover
Measures ground resistance from 0.025 W to 1500 W. from a lightning strike. The purpose
Measures ground leakage current from 0.2 mA to 30 mA. of a ground, besides the protection
High and Low alarming. of people, plants and equipment,
Automatic self calibration. is to provide a safe path for the
Rugged carrying case and resistance check loop included. dissipation of fault currents, lightning
Two-year warranty. strikes, static discharges, EMI and
RFI signals and interference.

Fluke 1621 Basic Earth Ground Tester


Earth ground tester for resistance measurement

The Fluke 1621 Earth Ground Tester is a rugged,


easy-to-use tester for 3-pole ground resistance
measurements and 2-pole ac resistance
measurements.
Earth ground resistance is measured by installing
earth ground test electrodes, and testing with the
Fluke 1621. Earth ground resistance measurements
are used to ensure safe operation and reduce power
quality problems. With a simple user interface and
intuitive functionality, the large, clear LCD display
provides high visibility results in daylight or poor
lighting conditions. The 1621 is lightweight making
it ideal to test for lightning protection levels and
periodic check-ups during routine maintenance. Included accessories
3-pole earth resistance measurements. Fluke 1630: Rugged carrying case
2-pole ac resistance measurements. with belt, resistance test loop, 9 V
AC/DC voltage measurement. battery and users manual.
Large dual backlit display. Fluke 1621: Two measuring leads
Limit settings for automatic measurement with alligator clips, 2 m (6 ft), yel-
evaluation. low protective holster, 9 V alkaline
600 V CAT II. battery (LR61), users manual, and
Two-year warranty. CD-ROM.
Feature comparison on page 16. Ordering information
FLUKE-1630 Earth Ground
Recommended accessories 1621 Earth Ground Tester Clamp Meter
FLUKE-1621 Basic Earth Ground
Tester
These products are for unpowered
installations measuring grounding
connections.
ES-162P3 Cable Reel 50 m Cable Reel 25 m Earth Stake
Stake/reel set for Ground/earth wire Ground/earth wire Ground/earth stake
3-pole measurements (162.5 ft) (81.25 ft)

For more information, go to www.fluke.com/egt Earth Ground Testers 17


Fluke 430 Series Three-Phase
Power Quality Analyzers
Pinpoint power problems faster, Sixsimple ways to reduce
safer and in greater detail costs with a Fluke 434
Power Quality Analyzer
The Fluke 435 and 434 Three-Phase Power Quality There are hundreds of power quality
Analyzers help you locate, predict, prevent and trouble- measurements you can take on
shoot problems in three- and single-phase power distri- electrical
bution systems. Troubleshooting is faster with on-screen systems and
display of trends and captured events, even while back- equipment.
ground recording continues. The new IEC standards for These
flicker, harmonics, and power quality are built right in to instructions
take the guess work out of power quality. focus on four
Troubleshoot real-time: predictive
Analyze the trends maintenance
using the cursors and (PdM)
zoom toolseven while measurements
background recording and two power
continues. consumption
AutoTrend: Every measurements
measurement you see that can help
is always automatically you uncover
recorded, without any setup. hidden costs, protect equipment
Automatic Transient from damaging conditions, reduce
Fluke 435
Mode: Capture 200 kHz unscheduled downtime, and improve
waveform data on all system performance.
phases simultaneously
Download this application note at
up to 6 kV.
www.fluke.com/six-ways.
Measure all three
phases and neutral:
With included four
current probes.
Fully Class-A compliant: Conduct tests according to
the stringent international IEC 61000-4-30 Class-A
standard.
System-Monitor: Up
to ten power quality More PQ info online at
parameters on one screen www.fluke.com/pq
according to EN50160
power quality standard Get a free PQ training DVD
Inrush mode: For www.fluke.com/PQ-DVD
troubleshooting nuisance
circuit breaker tripping. Sign up for a PQ seminar
Fluke 434 Logger function: www/fluke.com/FPQseminar
Configure for any test condition with memory for over
400 parameters at user defined intervals.

Features 435 and 434 PQ Analyzers


Features 435 434*
Measures voltage, current, dips, swells, Included accessories
interruptions, harmonics, inter-harmonics,
flicker, power, energy, transients, frequency,
Fluke 435: Hard carrying case with
unbalance, inrush, EN50160 overview rollers, four flexible current probes
Logger function with multi-parameter logging Optional* (i430 Flex), five test leads and clips,
Mains signaling Optional* battery charger, FlukeView software,
Memory size 16 MB 8 MB Power Log software, optical USB
Current probes 3000 A flexible (4) 40 A/400 A clamp (4) cable, color localization set, getting
Carrying case Water-tight hard case with rollers Rugged hard case started manual, users manual on
Software Fluke Power Log and FlukeView FlukeView CD-ROM.
Three-year warranty
Fluke 434: Hard carrying case,
*Optional functionality can be added with upgrade kit.
four current probes (i400s), five test
Recommended accessories 435 and 434 PQ Analyzers leads and clips, battery charger,
FlukeView software, optical USB
cable, color localization set, getting
started manual, users manual on
CD-ROM.

I5sPQ3 i430-flex-4pk C435 GPS430 Ordering information


3 pack of 5 A 4 pack of 3000 A Water-tight hard GPS time FLUKE-435 Three-Phase Power
precision current flexible current case with rollers synchronization
clamps probes module Quality Analyzer
See page 59. See page 59. FLUKE-434 Three-Phase Power
Quality Analyzer

18 Power Quality Analyzers For more information, go to www.fluke.com/pq


Fluke 345 Power Quality
Clamp Meter
The ideal meter for commissioning and Basic power quality
troubleshooting modern electrical loads measurements on the go
with the Fluke 345
A great
With a bright color display to analyze the harmonic spectrum, introduction to
a low-pass filter to remove high frequency noise, and a high power quality, Basic power quality
measurements on the
EMC immunity design, the Fluke 345 is ideal for measurements this short go with the Fluke 345
Application Note

on switching loads such as variable speed drives, electronic application During your day-to-day
measurement activities,
there may be situations
A power quality clamp
meter like the Fluke 345
combines a clamp meter,

lighting and UPS systems. Additionally, the Hall Effect note teaches
where you need to know power quality meter, oscil-
more than what voltage or loscope and data logger
current is present. When in one. This combination
that happens, the standard of functions coupled with
clamp meter isnt going to high quality digital filtering

measurement system makes measurement of dc current the basics of


get the job done. The solu- makes it ideal for working
tion may be a power quality with variable speed motor
clamp meter such as the drives, high efficiency light-
Fluke 345. ing, and other loads using
switching electronics.

possible without the need to break the circuit, and the internal simple voltage, The basics
Of course, the Fluke 345 will make the basic mea-

memory enables long-term logging for analysis of trends or


surements of voltage and current to determine if

current,
there is something seriously wrong with the circuit
under test. Its rated for use at the service entrance
with a 600 Volt CAT IV rating.
Measuring voltage is as simple as using a clamp
meter: Connect the test leads up to the voltage

intermittent problems.
inputs, select voltage, and then read the rms volt-

waveform,
age. Current measurement is just as easy. Select
current, open the jaw, clamp around the wire and
measure. With the 2000A range and large jaw

AC/DC current: Clamp-on measurement of ac peak and dc


opening, you can evaluate most of the circuits in
the building.

harmonics,
The Fluke 345 can also measure both ac and dc
voltage and current simultaneously, and identify
the magnitude of each separately and combined as
ac+dc true-rms. Thats helpful for checking a UPS,
battery, and output, to make sure that the circuits

current up to 2000 A without breaking the circuit.


are working correctly and the batteries are in good

power, inrush,
condition. A dc voltage component on the output
of a UPS or even an adjustable speed motor drive
may even be a quick indicator of a developing
problem. For example, waveform non-symmetry

Highest safety rating: 600 V CAT IV/1000 V CAT III rated for
will cause an apparent dc voltage component and
may indicate impending failure of system output

and logging
electronics.

use at the service entrance. measurements From the Fluke Digital Library @ www.fluke.com/library

Accurate measurement of parameters: Even with distorted using the


waveforms present on electronic loads with low-pass filter. Fluke 345. Learn how to read
Data logging: Identify intermittent faults by logging any waveforms and how and where
power parameters for minutes or months, including harmonics. to use them, and then learn about
Verify batteries: Direct measurement of dc ripple (%) for harmonics and how they distort
battery and dc systems. voltage and current.
Troubleshoot harmonics: Analyze and log harmonics Download this application note at
digitally or graphically.
www.fluke.com/345-apps.
Inrush current: Capture and analysis from 3 seconds to
300 seconds.
Easy-to-use: Easily confirm instrument setup with large
backlit color display of waveforms and trends.
Three-phase power: Built in capability for balanced loads.
View graphs and generate reports: With included Power
Log software.
One-year warranty for accessories.

Fluke 43B Power Quality Analyzer


Power quality analysis plus a scope and a meter

The Fluke 43B Power Quality Analyzer performs the


measurements you need to maintain power systems,
troubleshoot power problems, and diagnose equipment
failures. The 43B has 20 storage locations and can store
data as well as screens.
NiMH battery provides extended operating time of Included accessories
6.5 hours. Fluke 345: Batteries, pair of mea-
Voltage, current, and power harmonics up to 51st. suring leads, alligator clips, users
Total harmonic distortion (THD). manual, Power Log software, inter-
Phase angle of individual harmonics. face cable pouch, and calibration
FlukeView software with enhanced analysis and certificate.
documentation capabilities.
Fluke 43B: Hard case, voltage
Continuously measure volts and amps cycle-by-cycle
and current probes, FlukeView
for up to 16 days.
software, power quality instructional
Cursors give time and date of sags and swells.
CD, USB interface cable, line voltage
Watts, power factor, displacement power factor, VA
adapter/battery charger and users
and VAR.
manuals.
Voltage and current waveforms.
Calculates three-phase power on balanced loads Ordering information
from a single-phase measurement. FLUKE-345 AC/DC Power
Catch up to 40 voltage transients and waveform Quality Clamp Meter
distortions. FLUKE-43B Power Quality Analyzer
Three-year warranty for the PQ Analyzer.
One-year warranty for accessories.

For more information, go to www.fluke.com/pq Power Quality Analyzers 19


Fluke 1740 Series Three-
Phase PQ Loggers Memobox
Assess power quality and Power quality recording and
conduct long-term studies with ease analysis: Techniques and
applications
Hooking up a
Compact and rugged, the Fluke 1740 Series
power quality
Three-Phase Power Quality Loggers are
Power quality recording
and analysis: Techniques
recorder and and applications

everyday instruments for technicians who Application Note

taking days
troubleshoot and analyze power distribution
Hooking up a power quality recorder and taking
days worth of data can give you a rich picture Recording techniques

worth of
of your power. In this article well talk about the
To really know your power, ideally,
various recording techniques available in power
youd want to look at every line
loggers and recordersunderstanding the tools

systems. Capable of simultaneously logging


cycle to see even the smallest
and techniques you have available will be key to changes. However, since our power
your strategy. What should you be looking for? swings through more than four

data can give


And when does recording make sense? million cycles per day, its impracti-
cal to look at tiny changesand
often unnecessary. Few loads even

up to 500 parameters for up to 85 days and


notice occasional voltage dips of
one or two cycles.
How long you record depends

you a rich
somewhat on the rhythm of your
building. If you are working on a
typical commercial or light indus-

capturing events, the Fluke 1740 Series helps


trial building, then a week is long
enough for a building to go through
its normal cycle. If you are work-

picture of your
ing in a plant that runs special
equipment only periodically (say

uncover intermittent and hard-to-find power


a furnace that runs only monthly),
youll need to be sensitive to the
timing of these loads.

power. In this
Different recording techniques
have been developed to look at
small changes over relatively long

quality issues. The included PQ Log software


time periods. Many instruments
combine several techniques to
improve their coverage. Well

article well
describe the common techniques
and some of their pros and cons.
By understanding the different

quickly assesses the quality of power at the


techniques. youll be better able to
choose an appropriate tool for the
job at hand.

talk about
service entrance, substation, or at the load,
the various
Setting up a Fluke 1735 Power Logger at the service entrance for a
30-day load study.

according to the latest EN50160 standard.


recording
Plug and play: Setup in minutes with techniques
F ro m t h e F l u k e D i g i t a l L i b r a r y @ w w w. f l u k e . c o m / l i b r a r y

automatic current probe detection and


available in power loggers and
powering.
recorders; understanding the tools
Installs inside the cabinet: Compact, fully- and techniques you have available
Fluke 1744/1743 insulated housing and accessories fit easily
will be key to your strategy. What
in tight spaces, next to live power.
should you be looking for? And
Determines the root cause: Included when does recording make sense?
PQ Log software quickly analyzes trends,
creates statistical summaries, and Download this application note at
generates detailed graphs and tables. www.fluke.com/FN-logging.
Monitors power for the long-term: Data
can be downloaded during recording
without interruption.
Measure voltage with premium accuracy:
IEC61000-4-30 Class-A compliant voltage
accuracy (0.1 %).
Fluke 1745 Quickly validate quality of power: Assess
power quality according to EN50160 power
quality standard, with statistical overview.
Rugged and reliable: Designed for
everyday field use, with no moving
parts and durable, insulated case, with a
two-year warranty.

Features 1740 Series PQ Loggers


Features 1745 1744 1743
Measures common power parameters: V, A, W, VA, VAR,

PF, energy, flicker, voltage events, and THD
Measures voltage and current harmonics to the 50th,

unbalance, and mains signaling
Dust/water resistance IP50 IP65 water proof
Included accessories
4 Flexible probes 15/150/1500/
Display LED + LCD LED LED
3000 A with 2 m cable, PQ Log
UPS ride-through 5 hours 3s 3s software, RS-232 interface cable
Dimensions (HxWxD) 282 mm x 216 mm x 74 mm 170 mm x 125 mm x 55 mm and RS-232 USB adapter, 4 black
(11.5 in x 8.8 in x 3 in) (6.9 in x 5.1 in x 2.2 in)
dolphin clips, test leads for voltages
Two-year warranty
and power supply, color localization
kit, carrying bag, test certificate with
measurement values, printed English
Recommended accessories 1740 Series PQ Loggers users manual and multi-language
manual CD-ROM.

Ordering information
FLUKE-1743 Power Quality
Logger Memobox
MBX CLAMP 1 A/10 A + N MBX 300 POLESET C435
FLUKE-1744 Power Quality
3-phase+N current clamps Pole mounting kit for 1743 and 1744 Water-tight hard case with rollers Logger Memobox
2 m cable FLUKE-1745 Power Quality
Logger Memobox

20 Power Quality Analyzers For more information, go to www.fluke.com/pq


Fluke 1735 Three-Phase
Power Logger
Electrical load studies, energy consumption 30 Day Load Studies with
testing, and general power quality logging the Fluke 1735 Power
Logger
When a build-
The Fluke 1735 Three-Phase Power
ing owner 30 Day Load
Logger is the ideal electrician or Studies with the
wants you to Fluke 1735
technicians tool for conducting energy Power Logger Application Note

add new loads


studies and basic power quality logging.
When a building owner wants
you to add new loads to an exist-

to an existing
ing service or set of feeders, the
first thing you have to is deter-
mine whether the existing sys-

Set up the 1735 in seconds, with the


tem will support the new loads.
If you have a 600 amp service
installed in a facility, can you add

service or set
another 100 amps of load?
To answer this question you
have to ask another one: What is

included flexible current probes and


the highest load the system car-
ries now?
Often, local electrical authori-

of feeders,
ties will need to know these
answers before they issue per-

color display. The 1735 logs most


mits. Youll also need a compre-
hensive understanding of todays
loading to evaluate the new sys-

the first thing


tem, once installed.
To determine the existing
equipments capacity, factor in

electrical power parameters, harmonics


the incoming conductor size, the
ratings of the equipment, and
space for new circuits. To deter-

you have to
mine present loading, youll need
to either precisely calculate the
The NEC specifies that: Recording Current
existing loads, or measure them. The highest demand is the and Power with the

and captures voltage events.


Article 220 of the 2005 highest demand among all Fluke 1735
National Electrical Code offers feeders.
The compact, rugged Fluke 1735
two measurement methods for Take the measurements when

determine is
Power Logger is an excellent tool
determining existing loads and the building is occupied. for performing load studies.
the maximum demand the system
is likely to handle.
Include heating or cooling It includes flexible current
loads, whichever is larger, or probes for connecting around
The NEC defines demand as correct to account for these multiple conductors or bus bars.
the power consumption of the loads.
It has a PC interface and

whether the
loads averaged over 15-minute
intervals. Add in any other periodic software for downloading
loads. measurements to a Win-
The primary NEC method is to
find the maximum demand dur- As always, local authorities dows-based PC and creating
ing a one-year period. This only are responsible for interpreting professional reports for your
works if you have a years worth the Code and measurements. electrical plans.

existing
of demand data. Local regulations determine
when a load study must be per-
It measures voltage on three
The alternate method is to phases and current on three
record the demand over a 30-day formed, exactly what information phases and neutral.
period and find the maximum is required, and the review pro-
demand. This article describes cess. Make sure you understand It records multiple parameters
that can help determine system
your local requirements before

system will
the 30-day recording method, load, including voltage, current,
known as a load study. you start a load study.
frequency, real power (kW),

From the Fluke Digital Library @ www.fluke.com/library

support the
new loads.
If you have a 600 amp service
installed in a facility, can you add
Record power and associated parameters Improve reliability by capturing voltage another 100 amps of load?
for up to 45 days. dips and swells from load switching. To answer this question you
Monitor maximum power demand over Easily confirm instrument setup with have to ask another one: What is
user-defined averaging periods. color display of waveforms and trends. the highest load the system car-
Prove the benefit of efficiency improve- Measure all three phases and neutral with ries now? Often, local electrical
ments with energy consumption tests. included four flexible current probes. authorities will need to know these
Measure harmonic distortion caused by View graphs and generate reports with answers before they issue permits.
electronic loads. included Power Log software.
Two-year warranty. Compact, rugged design with IP65 case, Download this application note at
600 V CAT III. www.fluke.com/FN-loadstudy

Recommended accessories 1735 Three-Phase Power Logger

MBX Clamp 1 A/10 A MBX Clamp 5 A/50 A +N C435


3 precision dual range 4 precision dual range Water-tight hard case with rollers
current clamps (1 A/10 A) current clamps (5 A/50 A)

Included accessories
Fluke 1735: Four flexible cur-
Fluke VR1710 Power Quality Recorder rent probes (15 A/150 A/3000 A),
Detect and record voltage quality problems Power Log software, voltage leads
and clips, color localization set, PC
interface cable, international ac
The Fluke VR1710 is a single-phase, plug-
adapter (115 V/230 V, 50 Hz/60 Hz),
in, voltage quality recorder that offers an
soft carrying case, printed English
extremely easy-to-use solution for detecting
manual and multi-language manual
and recording power quality problems,
CD-ROM.
allowing for immediate action and less
downtime. Power quality parameters Fluke VR1710: USB cable, Power
including RMS average, transients, flicker, and Log software CD-ROM, universal
harmonics up to the 32nd are recorded using power cord adapters.
a user-selected average period from three Fluke VR101S: VR101, optical
seconds to ten minutes. With the unit, you interface cable, and EventView
will receive a USB cable, universal power cord software on CD-ROM.
adapters, Power Log software for reporting,
Fluke VR101: Instruction sheet.
and a one-year warranty.
Ordering information
FLUKE-1735 Three-Phase Power
Logger
VR1710 Voltage Quality
Recorder
VR101S Voltage Event
Recorder System
VR101 Voltage Event
Recorder
Note: At least one VR101S is required for
proper operation.

For more information, go to www.fluke.com/pq Power Quality Analyzers 21


Fluke 1750 Three-Phase
Power Recorder
The costs of poor power
Never miss capturing a disturbance quality
Productivity
is the key to
With its exclusive threshold-free survival in
measurement system, the Fluke 1750 Power todays global
Recorder automatically captures every competitive
measurement, every event, on every cycle, environment.
all the time. Unprecedented accuracy and Power quality
resolution provide complete visibility into problems
your distribution system. The recorder can cause
automatically detects, scales, and powers processes and
its current probes, while the PDA wirelessly equipment to
interfaces with the recorder, allowing quick malfunction
setup and verification. Ideal for long-term or shut down.
analysis, power quality surveys, quality of And the
service complaints, and semi-permanent consequences can range from
monitoring. excessive energy costs to complete
work stoppage. Obviously, power
tri
cal Sa
quality is critical.
c

fe

To reduce your power bill, you


Ele

ty

1000 V CAT III


600 V CAT IV need to record consumption patterns
and adjust the system and load
timing to reduce one or more of the
following:
Premium accuracy and measurement Plug and play: Set up in minutes with 1. Actual power (kWh) usage.
techniques: Guaranteed for all power self-identifying current probes and 2. Power factor penalties.
quality parameters, with IEC 61000-4-30 single-lead voltage connections. 3. A peak demand charge structure.
Class A measurement systems. No need to reconnect wires: Swap
Download this application note at
Quick and reliable configuration: PDA channels internally with the wireless
www.fluke.com/poor-pq-costs
wireless front panel interface provides PDA or PC when connections are not
a window into what the instrument correct.
is recording, even in awkward test Measure every parameter: Voltage and
locations. current on three phases, neutral, and
Threshold-free setup: Apply thresholds ground.
after data is collected with Fluke Power 5 MHz, 8000 Vpk waveform capture:
Analyze software. Get a detailed picture of even the
Captures everything: Cross-channel shortest events.
and current triggering capture every Quickly retrieve data: With included SD
measurement, on every channel, every memory card or via the 100BaseT high-
time. speed Ethernet connection.
Intuitive PC software: Easily analyze 600 V CAT IV and 1000 V CAT III safety
data and generate reports automatically. rating, on both the recorder and its
accessories. View measure-
ments real time
with wireless
Specifications 1750 Power Recorder PDA interface.

Power quality measurement standards


Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A or B depending
on measurement function, IEEE519, IEEE1159, IEEE1459
Included accessories
Clock/calendar Leap years, 24 hour clock
The Fluke 1750 includes the acquisi-
Real-time clock accuracy Not more than 1 s/day
tion unit, PDA and charger power
Internal memory capacity for data At least 1 GB
plug adapters, four 400 A current
Maximum recording period At least 31 days probes, five test leads and clips, SD
Measurement time control Automatic memory card, Fluke Power View
Maximum number of events Limited only by the size of the internal memory and Fluke Power Analyze software,
Power requirements 100 V rms to 240 V rms 10 %, 47 Hz to 63 Hz, 40 W power cord with international plug
Operating time during interruptions (internal UPS operation) 5 minutes per interruption, 60 minutes total operating time
without recharging
set, Ethernet cable, color localization
Dimensions 215 mm x 310 mm x 35 mm (8.5 in x 12.2 in x 3.5 in)
set, users manual and CD-ROM.
Weight 6.3 kg (14 lb)
Ordering information
Warranty One-year
FLUKE-1750 Three-Phase Power
Recorder
Recommended accessories 1750 Power Recorder In the U.S., these power quality
recorders are sold exclusively through
power quality representatives. To
request a demonstration, or to order,
call 1-888-257-9897 or email ques-
FLUKE-1750/CASE 3110-3312/RPM 3005R-3300
tions to fpqsupport@fluke.com.
Hard case Flexi-CT Series Clamp-On CT Series
Many configurations and accessories
are available for these recorders,
go to www.fluke.com/pq for more
information.
22 Power Quality Analyzers For more information, go to www.fluke.com/pq
Fluke 1760 Power Quality
Recorder Topas
Class-A compliance for the most What does Class A
demanding power quality tests mean to me?
The new IEC
61000-4-30
The Fluke 1760 Three-Phase Power Class A stan-
Quality Recorder is the ideal portable dard takes the
instrument for power quality experts. It is guesswork
fully compliant to IEC 61000-4-30 Class-A, out of select-
for advanced power quality analysis and ing a power
consistent compliance testing. Designed quality instru-
for analysis of utility and industrial power ment. The
distribution systems, in medium- and low- standard IEC
voltage networks, the Fluke 1760 provides 61000-4-30
the flexibility to customize thresholds, Class A
algorithms, and measurement selections. defines the
It captures the most comprehensive details measurement
on user-selected parameters and allows for methods for
later analysis and reporting. Comes with a each power quality parameter to
cal Sa
tri
two-year warranty. obtain reliable, repeatable and com-
c

fe
Ele

ty

1000 V CAT III parable results. It also defines the


600 V CAT IV
accuracy, bandwidth, and minimum
set of parameters. Going forward,
manufacturers can begin designing
Fully Class-A compliant: Conduct tests 10 MHz, 6000 Vpk waveform capture: to Class A standards, giving techni-
according to the stringent international Get a detailed picture of even the cians a level playing field to choose
IEC 61000-4-30 Class-A standard. shortest event. from and increasing their measure-
GPS time synchronization: Correlate 2 GB data memory: Enables detailed, ment accuracy, reliability, and effi-
data with events or datasets from other simultaneous recording of numerous ciency on the job.
instruments, with precision. power parameters for long periods of
Download this application note at
Flexible and fully configurable time.
www.fluke.com/ClassA
thresholds and scale factors: Allows Comprehensive software included:
user to pinpoint specific issues by Provides trend diagrams for root cause
defining the detailed criteria for detection analysis, statistical summaries, report
and recording of disturbances. writing, and real-time data monitoring
Highest safety rating in the industry: in the online mode.
600 V CAT IV/1000 V CAT III rated for Plug and play: Allows quick setup with
use at the service entrance. automatic sensor detection; sensors are
Uninterrupted power supply instrument powered, eliminating the Included accessories
(40 minutes): Never miss important need for batteries. Fluke 1760: Voltage probes (4),
eventseven record the beginning and Rugged field design: Insulated housing current probes (4), ethernet cable
end of interruptions and outages, to help and a solid state design with no rotating for network connection (1), cross-
determine the cause. components, enable reliable testing link ethernet cable for direct PC
under nearly any conditions. connection (1), mains cable (1),
GPS time sync receiver, PC software
on CD-ROM, users manual and
carrying case.
Fluke Norma 4000 and 5000:
Fluke Norma 4000 and 5000 Power supply cable, NormaView PC
Precision Power Analyzers software, test certificate, calibration
values, and color users manual.
The compact Fluke Norma Series Power
Analyzers include the latest power Ordering information
measurement technology to assist engineers FLUKE-1760 Without fast
with the development and testing of transient, voltage
motors, inverters, lighting, power supplies, or current option
transformers and automotive components. FLUKE-1760TR With fast transient
The series consists of the Fluke Norma 4000 option
Three-Phase Power Analyzer and the Fluke Norma 4000 High Precision
Norma 5000 Six-Phase Power Analyzer. A Power Analyzer
Fluke Norma 4000 variety of instrument configurations may be Norma 5000 High Precision
chosen to suit the users performance and Power Analyzer
price requirements; the analyzer range offers In the U.S., the 1760 Power Quality
world class accuracy of 0.2 % to 0.03 % Recorders are sold exclusively
depending on selected power phase module. through power quality representa-
All instruments are supplied as standard tives. To request a demonstration,
with RS-232 and USB interface with Fluke or to order, call 1-888-257-9897
NormaView software for data capture, analysis or email questions to fpqsupport@
and reporting. One-year warranty. fluke.com.
Fluke Norma 5000 Many configurations and accessories
are available for these recorders,
go to www.fluke.com/pq for more
information.

For more information, go to www.fluke.com/pq Power Quality Analyzers 23


Fluke 330 and 320 Series
Clamp Meters
Making accurate inrush
Get more done current measurements
New high-effi-
ciency motors
Fluke 330 Series Clamp Meters* require better
Inrush current feature (selected models). tools to evalu-
Small body and jaws fit perfectly in your hand ate and fix the
and into tight places. consequences
Controls positioned for one hand operation. of their high
Accurate low current measurements. inrush current.
Backlight available on most models. The Fluke
Auto shut-off. 335, 336 and
Display hold. 337 Clamp
Safety rating: IEC 1010-2-031, CAT III 600 V. Meters are
designed to
Fluke 320 Series Clamp Meters* capture inrush
Precise measurements with 1.8 % basic accuracy current accu-
Resolution up to 0.01 A and 0.1 V rately and, most importantly, syn-
Measures ac current 40.00 A/400.0 A chronously and provide readings
Measures ac and dc volts to 600 V that accurately depict what the
Resistance measurement to 400 W circuit protector experiences.
Continuity for quick checking of shorts This application note covers
*See specifications chart for details per model. practices to help you accurately
and safely measure and interpret
inrush current measurements.
Download this application note at
www.fluke.com/Inrush

Specifications 330 and 320 Series


Fluke 320 and 330 Series Clamp Meters offer an impressive array of innovative features with
current ranges up to 1000 A. Choose the model that matches the jobs you do.
(@23 C 5 C RH
0 to 90 %) Fluke 321 Fluke 322 Fluke 333 Fluke 334 Fluke 335 Fluke 336 Fluke 337
40.00 A/
Range to 400.0 A
400.0 A
to 400.0 A to 600.0 A to 999.9 A See also the Fluke
AC
current Accuracy
1.8 % + 5 counts 2 % + 5 counts 2 % + 5 counts 771 Milliamp Process
(50 to 60 Hz) (50 to 60 Hz) (10 to 100 Hz)
AC response Averaging True-rms Clamp Meter
Inrush Integration time 100 mS Measures, tests, and
0 to 0 to troubleshoots 4-20 mA
DC Range
current
600.0 A 999.9 A control signals without
Accuracy 2 % + 3 counts breaking the mA loop.
Range 400.0 V/600.0 V to 600.0 V See page 31 for more
AC 1.2 % + 5 counts 1 % + 5 counts 1 % + 5 counts
volts
Accuracy
(50 to 400 Hz) (50/60 Hz) (20 to 100 Hz) information.
AC response Averaging True-rms
400.0 V/
DC Range to 600.0 V
600 V
volts
Accuracy 1 % + 5 counts
Range to 400.0 W to 600.0 W 600.0 W/6000 W
Ohms
Accuracy 1 % + 5 counts 1.5 % + 5 counts
Continuity < 30 W
Range to 400 Hz
Hz 0.5 % + 5
Accuracy
counts
Min/Max Yes
Backlight Yes
Display hold Yes
HxWxD 19 cm x 6.3 cm x 3.5 cm 23.9 cm x 7.9 cm x 4 cm 25 cm x 7.9 cm x 4 cm
(7.5 in x 2.5 in x 1.4 in) (9.4 in x 3.1 in x 1.6 in) (9.9 in x 3.1 in x 1.6 in)
Size
Max wire dia. 2.5 cm (1 in) 3 cm (1.2 in)
Weight 0.22 gg (8 oz) 0.31 kg (11 oz)
Warranty Two-year Three-year Included accessories
Soft carrying case, test leads,
2 batteries, instruction card and
Recommended accessories 320 and 330 Series safety information.

Ordering information
FLUKE-321 FLUKE-335
FLUKE-322 FLUKE-336
FLUKE-333 FLUKE-337
TL223 H3 LVD2 TL71 FLUKE-334
SureGrip Electrical Test Lead Set Clamp Meter Holster Volt Light Premium Test Lead Set
See page 53. See page 62. See page 56. See page 54.

24 Clamp Meters For more information, go to www.fluke.com/clamps


Fluke 902 True-rms
HVAC Clamp Meter
Fluke 360 AC Leakage
Get more done Current Clamp Meter
1 A resolution
leakage current
HVAC (heating, ventilation, air conditioning) technicians require a measurements with
service tool that can consistently keep up with their demands. The a tough, pocket
Fluke 902 expands the existing line of quality Fluke clamp meters sized clamp
by delivering the features necessary to diagnose and repair HVAC The unique jaw
systems. Combined with true-rms technology and a CAT III 600 V design of the Fluke
rating, the Fluke 902 helps technicians do their jobs safely and 360 eliminates the
accurately. influence of adjacent
Designed for HVAC applications with capacitance, dc current (A), current conductors
and temperature measurements. and measures leakage
Small body and jaws fit perfectly in your hand and into tight current down to 1 A for
places. monitoring of insulation.
Handy Display Hold button keeps measurements on the display. The ergonomic design
Meter controls are positioned so current measurements can be of the Fluke 360 ensures
done with one hand (index finger on clamp opening lever and easy measuring. The
thumb on rotary switch). measuring clamp fits into
Three-year warranty. tight spaces and the wide
display angle clearly shows the
measurement result. The Data Hold
button keeps the measured value on
the display after removing the clamp
for the measured conductor.
The lightweight Fluke 360
offers the widest range of current
Specifications 902 Clamp Meter measurement for maintenance
professionals and contractors. Use
Features Range Accuracy the rugged Fluke 360 when its not
Voltage dc 0 to 600 V 1 % 5 counts possible to power down and break
Voltage ac (true-rms) 0 to 600 V 1 % 5 counts (50/60 Hz)
the circuit.
Current ac (true-rms) 0 to 600 A 2.0 % 5 counts (50/60 Hz)
Current dc 0 to 200 A 1.0 % 5 counts
Resistance 0 to 9999 W 1.5 % 5 counts
Current measurement
Continuity <= 30 W
Automatic ranging within the
Temperature range -10 C to 400 C (-14 F to 752 F) 1.0 % + 0.8 C ( 1.0 % + 1.5 F) typical 5.0 %
manually selected mA or A range.
-40 C to -10 C (-40 F to -14 F) + 1.5 C ( 5.0 % + 3.3 % F) typical Ranges 3/30 mA and 30/60 A.
Capacitance 1 F to 1000 F 1.9 % 2 counts Current resolution 1 A/0.01 mA
and 0.01 A/0.1 A.
See pages 46-47 for information on the HVAC/Indoor Air Quality Tools. Frequency range 50 and 60 Hz.
Jaw size: 40 mm (1.55 in)
maximum conductor diameter.
Auto power off.
One-year warranty.
Fluke 353/355 True-rms,
2000 A Clamp Meters
Well suited for industrial and utility applications Included accessories
Fluke 902: AA alkaline batteries
(2), users manual (with safety infor-
Reliably handle a wide range of high-current mation), soft carrying case, TL75
applications with 2000 A ac + dc true-rms, Test Leads (1 pair), 80BK Integrated
1400 A ac, and 2000 A dc. Temperature Probe (1).
Large 58 mm (2.3 in) jaw.
CAT IV 600 V, CAT III 1000 V. Fluke 353: C43 Soft Carrying Case,
In-rush current measurement. 6 AA batteries, and users manual.
High voltage measurement of 1000 V ac + dc Fluke 355: C43 Soft Carrying Case,
true-rms, 600 V ac, and 1000 V dc (355 only). 6 AA batteries, TL224 1.5 m Silicone
Resistance to 400 K ohms (355 only). Rubber Test Leads, TP2 Test Probes,
Continuity beeper (355 only). AC285 Alligator Clips, and users
Frequency measurement to 1 KHz. manual.
Selectable low pass filter mode. Fluke 360: Soft carrying pouch and
Min/Max/Avg. users manual.
Large display with backlight.
Ordering information
FLUKE-902 HVAC Clamp Meter
FLUKE-353 AC/DC True-rms Clamp
Meter, 2000 A,
Amps only
N10140 FLUKE-355 AC/DC True-rms Clamp
Meter, 2000 A
FLUKE-360 AC Leakage Current
Clamp Meter
(not available in Canada)

For more information, go to www.fluke.com/clamps Clamp Meters 25


Fluke T5, T+PRO and T+
Electrical Testers
Alternatives to traditional
solenoid testers
Fluke
1AC-II/1LAC-II
Fluke T+PRO and T+ Electrical Testers VoltAlert
Three forms of ac/dc voltage detection: Light,
sound, and vibration. The pocket-sized voltage detector
Detects live voltage even when The next generation VoltAlert ac
batteries are dead. non-contact voltage testers from
Extra heavy-duty, replaceable Fluke are easy to usejust touch
test leads. the tip to a terminal strip, outlet, or
CAT IV 600 V, CAT III 1000 V supply cord. When the tip glows
rated. red and the unit beeps, you know
Continuity beeper, LED flashlight there is voltage present. Electricians,
and GFCI trip. maintenance, service and safety
personnel and homeowners can
Fluke T5 Voltage, quickly test for energized circuits in
Continuity and Current the workplace or at home. Certified
up to CAT IV 1000 V.
Tester
Excellent front-line trouble- Two models to choose from:
shooting and measurement tool. 1AC-II Detects voltage from
Available in 600 V and 1000 V 90 V ac to 1000 V ac.
models. 1LAC-II Detects voltage from
Digital display. 20 V ac to 90 V ac.
OpenJaw current measurement. Two-year warranty.
Rotary switch selects volts, amps
and ohms functions.
Heavy-duty test leads.

Fluke LVD2
Volt Light
Specifications T+ Series and T5 Testers Non-contact ac voltage
detector and bright white
Features T+PRO T+ T5-1000 T5-600 LED flashlight.
Measure ac/dc voltage Preset 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 1000 V 600 V Detects voltage from 90 V to
277 V (Canada 347 V), 480 V, 600 V 600 V ac from 1 to 5 inches away.
Measure ac current (average) 100 A 100 A Cat IV rated, one-year warranty.
Measure continuity Yes Yes < 25 W < 25 W
Measure resistance 9.99 kW 1000 W 1000 W
DC polarity indicator Yes Yes
Detachable probe tips with Yes Yes Yes Yes
optional probe tips styles Included accessories
Digital display Yes No Yes Yes The T5-1000 and T5-600 come
Safety rating CAT IV 600 V/ CAT IV 600 V/ 1000 V Overvoltage 600 V Overvoltage
CAT III 1000 V CAT III 1000 V CAT III CAT III with detachable probes and
Warranty Two-years Two-years Two-years Two-years instruction sheet.
* Voltage levels will vary depending on country of intended use.
Ordering information
T+PRO Electrical Tester
T+PRO CAN Electrical Tester
Buy Electrical Tester Kits and Save T+ Electrical Tester
T+ CAN Electrical Tester
T+PRO-1AC Kit
Electrical Tester and AC
Voltage Detector Kit
T+PRO CAN-1AC Kit
T+PRO-1AC Kit T5-1000 Tester Kit VoltAlert Multi Pack Electrical Tester and AC
Combo kit includes: Combo kit includes: Includes five Fluke VoltAlerts. Voltage Detector Kit
Fluke T+Pro Electrical Tester Fluke T5-1000 Voltage The special kit pricing gets you T5-1000 1000 V Voltage,
Fluke VoltAlert Electrical Tester the fifth VoltAlert free. Outfit Continuity and
Fluke VoltAlert your entire staff. Current Tester
Fluke H5 Holster T5-600 600 V Voltage,
Continuity and
Current Tester
Recommended accessories Electrical Testers T5-H5-1AC Voltage, Continuity
Kit and Current Tester Kit
1AC-II 5PK VoltAlert 5 Pack
1AC-II Voltage Detector
1LAC-II Voltage Detector
H5 AC285 (T5) Meter Cleaner T5 Kit C520A
9040 Rotary Field Indicator
Electrical Tester Holster SureGrip Alligator Clips Cleaning Wipes Starter Kit Leather Tool Case LVD2 Volt Light
See page 62. See page 54. See page 63. See page 53.

26 Electrical Testers For more information, go to www.fluke.com/tseries


Fluke 1550B
MegOhmMeter
Powerful troubleshooting and Fluke 1507/1503
predictive maintenance tools Insulation Resistance
Testers
These light-
The 1550B automatically calculates
weight, afford-
polarization index and dielectric absorp-
able insulation
tion ratios. The 1550B features:
testers are
Standard test voltages of 250 V, prefect for
500 V, 1000 V, 2500 V and 5000 V
troubleshooting,
for a wide range of equipment testing.
commissioning,
Programmable test voltages available and preventive
in 50-volt steps from 250 V to
maintenance
1000 V and 100-volt steps from
applications.
1000 V to 5000 V.
Automatic calculation of Dielectric Standout
Absorption Ratio (DAR) and Polarization
Index (PI) with no additional setup. features:
Easy setup saves time and effort when Automatic
conducting timed and ramp test of calculation of
insulation breakdown. polarization
Improved ramp function (0 V dc to index and
5000 V dc) for breakdown testing. dialectric
Autodischarge of capacitive voltage. absorption ratio
Measures resistances up to one (1507 only)
teraohm. Multiple test voltages: 50 V,
Includes improved FlukeView 100 V, 250 V, 500 V, 1000 V
Forms Software and Optical Interface (1507 only)
cable for easier downloading to a Remote test probe for rapid testing
Windows PC.
Other features:
Insulation test range 0.01 MW to
Specifications 1550B MegOhmMeter 10 GW (1507), 0.1 MW to 2000 MW
(1503).
The meters accuracy is specified for one year after calibration at operating temperatures of 0 C to 35 C. For operating tempera-
tures outside the range (-20 C to 0 C and 35 C to 50 C), add .25 % per C, except on the 20 % bands add 1 % per C.
Compare (Pass/Fail) function for
repetitive tests (1507 only).
Insulation resistance measurement Live circuit detection prevents
Test Voltage (dc) Range Accuracy ( reading) insulation test if voltage > 30 V is
200 kW to 5 GW 5%
250 V
5 GW to 50 GW 20 %
detected.
200 kW to 10 GW 5% Auto-discharge of capacitive
500 V
10 GW to 100 GW 20 % voltage.
1000 V
200 kW to 20 GW 5% AC/DC voltage: 0.1 V to 600 V.
20 GW to 200 GW
200 kW to 50 GW
20 %
5%
Lo Ohms/Earth-bond continuity
2500 V
50 GW to 500 GW 20 % (200 mA) for checking connections
200 kW to 100 GW 5% and motor windings.
5000 V
100 GW to 1 TW 20 % Resistance: 0.01 W to 20.00 W.
One-year warranty.
Functions Range Accuracy ( reading) CAT IV 600 V.
Leakage current 1 nA to 2 mA (5 % + 2 nA)
Capacitance measurement 0.01 uF to 15.00 F (15 % rdg + 0.03 F)
Live circuit indicator 30 V to 600 V ac/dc, 50/60 Hz (5 % + 2 V)

Short circuit current: Greater than 1 mA and less than 2 mA Charger input (ac): 85 to 250 V ac, 50/60 Hz, 50 VA
Bargraph range: 0 to 1 T Operating temperature: -20 C to 50 C (-4 F to 122 F)
Insulation test voltage accuracy: -0 % to +10 % at 1 mA Storage temperature: -20 C to 65 C (-4 F to 149 F)
load current Relative humidity: 80 % at 31 C decreasing linearly to 50 %
Induced ac mains current rejection: 2 mA maximum at 50 C
Charging rate for capacitive load: 5 seconds per F Operating altitude: 0 to 2000 meters
Timer: 0 to 99 minutes; settable in 1 minute increments; indi- Enclosure sealing: IP 40
cated to within 1 second Safety conformance: EN 61010-1, CAT III, 600 V, EN61557,
Ramp: 0 % to 100 % of selected test voltage, or until breakdown Parts 1 & 2
Dimensions (HxWxL): 330 mm x 242 mm x 170 mm (13 in x Input overload protection: 600 V ac continuous
9.5 in x 6.7 in) Warranty: Two-years
Weight (with battery): 4 kg (8.8 lb) Software: FlukeView Forms Basic Software requires a
Battery type: 12 V, lead-acid, rechargeable PC running Windows 95, 98, Me, 2000, NT4.0
Included accessories
Fluke 1550B: Test leads, 5000 V
rated probes, alligator clips, inter-
Recommended accessories 1550B MegOhmMeter face adapter and cable, FlukeView
Forms Basic software, line cord, soft
carrying case, and users manual.
Fluke 1507/1503: Remote probe,
test leads, test probes, alligator clips,
holster and users manual.
FVF-UG TL1550EXT L206


FlukeView Forms
Software Upgrade
25 Foot Extension
Test Lead Set
Deluxe LED Hat Light
See page 56.
Ordering information
See page 57. FLUKE-1550B MegOhmMeter
FLUKE-1507 Insulation Tester
FLUKE-1503 Insulation Tester

For more information, go to www.fluke.com/1550 Insulation Resistance Testing 27


Fluke 1587 and 1577
Insulation Multimeters
Get the most value and
Two powerful tools in one productivity from Fluke kits
Establishing a preventive mainten-
ance program is becoming critical to
The Fluke 1587 and 1577 Insulation Multimeters combine a maintaining the uptime of electrical
digital 1 kV insulation tester with a full-featured, true-rms equipment and can significantly
digital multimeter in a single compact, handheld unit, which reduce both planned and unplanned
provides maximum versatility for both troubleshooting and pre- downtime. Unplanned downtime
ventive maintenance. Whether you work on motors, genera- costs are difficult to calculate, but are
tors, cables, or switchgear, the Fluke 1587 and 1577 Insulation often significant. For some industries,
Multimeters are ideally suited to help you with your tasks. it can represent 1 % to 3 % of
Insulation test (1587: 0.01 MW to 2 GW) (1577: 0.1 MW to revenue (potentially 30 % to 40 % of
600 MW). profits) annually.
Insulation test voltages (1587: 50 V, 100 V, 250 V, 500 V, These kits can help you be
1000 V), (1577: 500 V, 1000 V) for many applications. proactive and efficient with your
Live circuit detection prevents insulation test if voltage maintenance and can save you up
> 30 V is detected for added user protection. to 10 % off the individual price of
Auto-discharge of capacitive voltage for added the tools.
user protection. Fluke 1587/ET Advanced Electrical
Filter for motor drive measurements (1587 only). Troubleshooting Kit includes:
AC/DC voltage, dc millivolts, ac/dc milliamps,
resistance (W), and continuity.
Capacitance, diode test, temperature, Min/Max, and
frequency (Hz) (1587 only).
Auto power off to save battery power.
Large display with backlight and large digits.
Included accessories: Remote probe, test leads and probes,
alligator clips, (K-type thermocouple, 1587 only).
Accepts optional Fluke TPAK magnetic hanging system to
free your hands for other work.
Rugged, utility hard case allows you to bring everything
you need for the job.
Three-year warranty. Fluke 1587 Insulation Multimeter
Fluke i400 Current Clamp
Fluke 62 Mini Infrared
Themometer
Fluke 1587/MDT Advanced Motor
Specifications 1587 and 1577 Multimeters and Drive Troubleshooting Kit
includes:
Features 1587 1577 1507 1503
Insulation test voltages 50 V, 100 V,

250 V, 500 V, 1000 V
Insulation test voltages 500 V, 1000 V
Insulation test: 0.01 MW to 2.0 GW 0.01 MW to 2.0 GW 0.1 MW to 600 MW 0.01 MW to 10 GW 0.1 MW to 2 GW
Auto-discharge of capacitive voltage
Insulation test smoothing reading
Frequency
Capacitance
Diode test
Temperature
Min/Max
Low-pass filter (for work on VSDs)
AC/DC Voltage
Fluke 1587 Insulation Multimeter
DC millivolts
Fluke i400 Current Clamp
AC/DC milliamps
Fluke 9040 Phase Rotation
Resistance 0.1 W to 50 MW 0.1 W to 50 MW 0.1 W to 20.00 KW 0.1 W to 20.00 KW Indicator
Continuity
Warranty Three-year Three-year One-year One-year
Remote probe, test leads, alligator clips Included accessories
K-type thermocouple Remote probe, test leads, alligator
Rugged, utility hard case
clips, K-type thermocouple (1587 only),
Auto power off
hard case and users manual.

Ordering information
FLUKE-1577 Insulation
Recommended accessories 1587 and 1577 Multimeters Multimeter
FLUKE-1587 Insulation
Multimeter
FLUKE-1587/ET Advanced
Electrical
Troubleshooting Kit
FLUKE-1587/MDT Advanced Motor
ToolPak i400s C25 TL27
Meter Hanger AC Current Clamp Meter Case Heavy Duty Test Leads and Drive
See page 63. See page 58. See page 62. See page 54. Troubleshooting Kit

For more information, go to


28 Insulation Resistance Testing www.fluke.com/1587
Pick the right
process tool for you

Process Tools Selection Guide

Precision
Intrinsically Documenting
Pressure Temperature Multifunction Process mA ProcessMeter
Loop Calibrator Safe Process
Calibrator Calibrator Process Clamp Meter Test Tool
Calibrator Calibrator
Calibrator
Models 715 718 724 726 725Ex 744 771 789
Measure
V dc 25 V 30 V 30 V 30 V 300 V 1000 V
V ac (true-rms) 300 V 1000 V
Resistance 3200 W 4000 W 3200 W 11 kW 40 MW
A dc 24 mA 24 mA 24 mA 24 mA 24 mA 110 mA 20.99, 99.9 mA 30 mA, 1 A
A ac
Frequency 15 kHz 10 kHz 50 kHz 20 kHz
Pressure 1 psi, 30 psi,
100 psi and 1 5 1
300 psi2
Temperature: RTDs 7 types 8 types 7 types 8 types
Temperature: TCs 12 types 13 types 12 types 13 types
Source/Simulate
V dc 20 V 10 V 20 V 10 V 15 V
Resistance 3200 W 4000 W 3200 W 11 kW
mA dc 24 mA 24 mA 24 mA 22 mA 24 mA

mA source; auto step,



auto ramp
Frequency 15 kHz 10 kHz 50 kHz
Temperature: RTDs 7 types 8 types 7 types 8 types
Temperature: TCs 12 types 13 types 12 types 13 types
Record
Min/Max
Hold
As found/As left results
Log data
Upload data to PC
Remote operation
Features
24 V loop supply 12 V
Non-contact measurement
HART communication

Integrated hand pressure



pump
Intrinsically safe (ATEX)
Warranty Three-years One-year Three-years Three-years Three-years Three-years Three-years Three-years

NIST traceable

certification
Accessories3 A/B C A/B A/B A/B
Pressure enabled4
See page 36 35 34 33 37 32 31 30

1Fluke 700 Pressure Modules required.


2Eitherthe internal sensor or a Fluke 700 Pressure Module may be used.
3Accessories: A. Compatible with LockPak B. Compatible with ToolPak C. Accepts hanging straps from ToolPak D. Optional accessories.
4Fluke Process Calibrators in this guide displaying the Pressure Enabled symbol display readings from the 700 Series Pressure Modules.
5Fluke 700PEx Pressure Module required.

For more information, go to www.fluke.com/726 Process Calibration Tools 29


Fluke 789 and 787
ProcessMeter Test Tools
In-field valve positioner
Safety rated multimeters with mA source checks
Valve positioners
open and close
Fluke 789 ProcessMeter with a 4 to
With the Fluke 789 ProcessMeter, process technicians 20 mA signal
can do a lot more while carrying a lot less. applied. This
24 V loop power supply. application note
HART mode setting with loop power explains how to
(adds 250 ohm resistor). adjust these
Double-sized, dual display. valves so they
20 mA drive into 1200 ohms . open and close
Backlight with two brightness settings. correctly.
0 % to 100 % mA Span Check buttons to toggle Download
between 4 mA and 20 mA. this application
Infrared I/O serial port compatible with FlukeView note at www.
Forms Software. fluke.com/valve-check
Improved battery power with four AA batteries.
Plus all the proven 787 features.
Fluke 787 ProcessMeter
Simultaneous mA and % of scale readout on
mA output.
25 % Manual Step plus Auto Step and Auto Ramp
on mA output.
Min/Max/Average/Hold/Relative modes.
Externally accessible battery for easy changes.

Designed and
Conforms to
IEC 1010-1
600V
CAT IV

(Fluke 789 only)

Specifications 789 and 787 ProcessMeter


Measurement function Best accuracy range and resolution (% of reading + LSD)
V dc 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.1 % + 1
V dc (true-rms) 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.7 % + 2
mA dc 30.000 mA .05 % + 2
A dc 1.000 A (0.440 A continuous) 0.2 % + 2
A ac 1.000 A (0.440 A continuous) 1%+2
Resistance 400.0 W, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M 0.2 % + 1
Frequency (0.5 Hz to 20 kHz) 199.99 Hz, 1999.9 Hz, 19.999 kHz .005 % + 1
Diode test 789: 2.000 V (shows diode voltage drop) 787: 2%+12%+1
2.400 V (shows diode voltage drop)
Continuity Beeps for resistance < approx. 100 ohms
Accuracy
Output function Range and resolution Drive capability
(% of span)
DC current output (internal 0.000 mA to 20.000 mA or 4.000 mA to 20.000 mA 789: 24 V compliance .05 %
battery operation) (selectable at power-up) Over-range to 24.000 mA or, 1,200 ohms,
@ 20 mA 787: 12 V
compliance or,
500 ohms, @ 20 mA
DC current simulate 0.000 mA to 20.000 mA or 4.000 mA to 20.000 mA, 1000 ohms, @ 20 mA .05 %
(external 24 V loop supply, (selectable at power-up) Over-range to 24.000 mA
up to 48 V on 789 only)
24 V loop supply 789: Minimum 24 V 787: Not available 250 ohms @ 20 mA > 24 V
Current adjustment modes Manual: Coarse, Fine, 25 % and 100 % step
Included accessories
(100 % step 789 only) Automatic: slow ramp, Fluke 789: TL71 Premium Safety-
fast ramp, 25 % step Designed Test Lead Set plus alliga-
Temperature range of 18 C to 28 C, for one year after calibration. tor clips, 4 AA alkaline batteries
Maximum voltage applied between any jack and earth ground:1000 V rms. Storage temperature: -40 C to 60 C. (installed), product overview and
Operating temperature: -20 C to 55 C. Relative humidity: 95 % up to 30 C; 75 % up to 40 C; 45 % up to 50 C; 35 % up to 55 C.
Safety: Designed in accordance with EN61010, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Over-voltage CAT III.
users manual on CD-ROM in 14
Size (HxWxL)/weight (787 with holster): 52 mm x 98 mm x 201 mm (2.06 in x 3.86 in x 7.93 in)/638 g (1.4 lb). languages.
Size (HxWxL)/weight (789): 50 mm x 100 mm x 203 mm (1.97 in x 3.94 in x 8.00 in)/600 g (1.3 lb).
Warranty: Three-year warranty. Fluke 787: Protective yellow holster
with test lead storage, TL75 Safety-
Recommended accessories 787 and 789 ProcessMeter Designed Test Lead Set plus alliga-
tor clips, one 9 V alkaline battery
(installed), product overview and users
manual on CD-ROM in 14 languages.

TL220 ToolPak 80T-150U C781 PV350


Ordering information
SureGrip Industrial Meter Hanging Kit Universal Soft Carrying Pressure Vacuum Module FLUKE-789 ProcessMeter
Test Lead Set See page 63. Temperature Probe Case See page 57.
See page 53. See page 61.
FLUKE-787 ProcessMeter

For more information, go to


30 Process Calibration Tools www.fluke.com/processmeters
Fluke 771 Milliamp
Process Clamp Meter
Measure 4 to 20 mA signals Steel mill keeps its
without breaking the loop emissions record stainless
Follow along
as the 771
The innovative new Fluke 771 mA Process Clamp Meter is tests control
designed to measure, test, and troubleshoot 4-20 mA control loops for sys-
signals without breaking the mA loop. Make mA measure- tem operations
ments in active control systems without disrupting process and emissions
control. at a steel mill.
Features: Users explain
Best in class 0.2 % accuracy. the benefits
Resolution and sensitivity to 0.01 mA. of milliamp
Hold function captures and displays changing percentage
measurements. readings and
Dual display with both mA measurement and dual milliamp
0 % to 100 % of 4-20 mA span. and percent of
Measurement spotlight illuminates hard to see scale readings as they monitor boiler
wires in dark enclosures. performance.
Detachable clamp with extension cable for Download this application note at
measurements in tight locations. www.fluke.com/FN-Steel 771
Includes carrying case that can be used as a belt
mounted holster.
Key uses:
Measure mA signals for PLC and control system
analog I/O.
Measure 4-20 mA output signals from transmitters.
Measure 10-50 mA signals in older control systems
using the 99.9 mA range.

N10140

Specifications 771 Process Clamp Meter


Range/Resolution Accuracy
-20.99 to +20.99 mA 0.2 % or reading + 5 counts
-21.0 to -99.9 mA 1 % reading + 5 counts
+21.0 to +99.9 mA
General specifications
Operating temperature -10 C to 50 C
Storage temperature -25 C to 60 C
Operating humidity <95 % @ <30 C, <75 % @ 30 C to 55 C
Operating altitude 0 m to 2000 m
IP rating IP 40
Size 59 mm x 38 mm x 212 mm, (2.32 in x 1.5 in x 8.35 in)
Weight 260 g, (9.1 oz)
Vibration random 2 g, 5 Hz to 500 Hz
Shock 1 meter drop test (excluding the jaw)
EMI, RFI, EMC Meets EN61326-1
Temperature coefficients 0.01 % / C, <18 C or > 28 C
Power, battery life (2) AA 1.5 V alkaline, IEC LR6, 20 hours typical Detachable clamp used to measure 4 mA
Category rating CAT II 300 V to 20 mA signals on transmitters without
Warranty Three-years for electronics, one-year for clamp cable assembly breaking the loop.

Related products 771 Process Clamp Meter

Included accessories
Carrying case, and instruction
manual.

Ordering information
FLUKE-771 Milliamp Process
Fluke 707 Fluke 125 Clamp Meter
Loop Calibrator ScopeMeter
See page 36. See page 49.

For more information, go to www.fluke.com/processmeters Process Calibration Tools 31


Fluke 741B, 743B and
744 Calibrators Pressure
Enabled

For the calibration and troubleshooting HART transmitter


of process control instrumentation calibration
The need for
calibration of
Calibrate temperature, pressure, voltage, current, HART smart
resistance and frequency instruments. transmitters is
Built-in procedures for transmitters, square root often misunder-
transmitters, pressure and temperature switches. stood. What do
Simultaneously measure and source. you calibrate
Automatically capture calibration results. and when?
Document procedures and results to meet ISO 9000, Here is a step-
EPA, FDA, OSHA, and other government requirements. by-step
Measure/simulate 13 types of thermocouples and procedure
eight RTDs. showing how
Store up to 8,000 readings in data logging mode to use the Fluke
(743B and 744 only). 744 to perform
Protected against dirt, dust and moisture; unaffected calibration and
by vibration. digital adjustments of Rosemount
Includes a PC interface (743B and 744 only). 3051 and 3144 transmitters and
Operate in English, French, German, Italian and Spanish. other HART devices.
Offer one- and two-year calibration cycles and a
Download this application note at
three-year warranty (one-year for pressure modules).
www.fluke.com/HART-Cal
744: Get HART-ability
The Fluke 744 offers all of the capabilities of the 743B, plus
the ability to calibrate, maintain, and troubleshoot HART
instrumentation. Integrated HART communication functions
permit you to monitor, control, and calibrate HART instru-
mentation. It handles fast pulsed instruments such as RTD
transmitters and PLCs, with pulses as short as 1 ms.
See www.fluke.com/744upgrade for the latest list of Instrumentation
HART instruments. management software
The Fluke 743B and 744 are compatible
741B: A complete documenting calibrator with Fluke 700SW DPC/TRACK software
The 741B is the economical choice for plants that dont use
and with software from Beamex,
PCs or that require traditional paper forms. It has storage
Cornerstone, Emerson, Honeywell,
capacity for a days calibration and measurement data. When
On Time Support, Prime Technologies,
youre back at the shop, recall the data on-screen to fill out
Yokogowa, Intools and Meridium.
calibration forms.
For more information, visit
743B: More memory, plus a PC interface www.fluke.com/software
and data logging
The 743B has all the capabilities of the 741B plus a PC
interface that lets you load procedures, lists, and instructions
created with softwareor unload data for printing, archiving, Included accessories
and analysis. With its expanded memory, the 743B can hold TL224 Industrial Test Leads (2 sets),
a full week of calibrations and procedures. AC220 Test Clips (2 sets), TP220
Test Probes, BP7217 Battery Pack,
BC7217 Battery Charger, instruction
Specifications 741B, 743B and 744 manual, NIST traceable calibration
certificate and data, serial port cable
Summary specifications: best case, (743B and 744 only), DPC/TRACK
Functions Measure Sourcing
DC voltage 0.025 % reading + 0.01 % output +
mid-range, one year. sample version with free PC commu-
0.005 % full scale 0.005 % full scale Battery life: Typically over eight hours nication utility software (743B and
Internal battery pack: NiCd, 7.2 V,
DC current 0.01 % reading + 0.01 % output +
1700 mAh, NiMH 3500 mAh on 744.
744 only).
0.015 % full scale 0.015 % full scale
Battery replacement: Via snap-shut Additional 744 accessories
Resistance 0.05 % reading + 50 m 0.01 % output + 40 m
door without opening calibrator; no
Frequency 0.05 % 0.01 % tools required BP7235 NiMH Battery Pack, HART
Thermocouples 0.3 C 0.2 C Weight: 1.4 kg (3 lb 1 oz) communications cable, HART users
RTDs 0.3 C 0.1 C Size (HxWxD): 236 mm x 130 mm x manual and NIST Traceable calibra-
61 mm (9.3 in x 5.1 in x 2.4 in)
Pressure To 0.25 % of full scale, per pressure tion certificate and data.
module specifications
Ordering information
Recommended accessories 741B, 743B and 744 FLUKE-741B Documenting Process
Calibrator
FLUKE-743B Documenting Process
Calibrator
FLUKE-744 Documenting Process
Calibrator
C789 Fluke-700PTP-1 Fluke-700Pxx 80PK-25 TL220
FLUKE-700S DPC/Track
Meter and Pneumatic Pressure Modules SureGrip Piercing SureGrip Industrial Software
Accessory Case Test Pump See page 35. Temperature Probe Test Lead Set
See page 62. See page 61. See page 60. See page 53.

For more information, go to


32 Process Calibration Tools www.fluke.com/740
Fluke 726 and 725 Multi-
function Process Calibrators
Step up to unmatched accuracy in Fluke 725 Multifunction
process measurement and calibration Process Calibrator Pressure

Measure volts, mA, RTDs, Enabled

thermocouples,
Fluke 726 Precision Multifunction frequency and ohms
to test sensors and
Process Calibrator transmitters
The Fluke 726 Precision Multifunction Process Calibrator
is designed specifically for the process industry with
Source/simulate
volts, mA,
broad workload coverage, calibration power and
thermocouples, RTDs,
unsurpassed accuracy in mind. The 726 measures and
frequency, ohms and
sources almost all process parameters and can calibrate
pressure to calibrate
almost anything. The 726 will also interpret results
transmitters
without the help of a calculator and store measurement
data for later analysis.
Measure/source
pressure using any
Precise measurement and calibration source of 29 Fluke 700Pxx
performance, accuracies of 0.01 %. Pressure Modules
Transmitter error% calculation, interpret calibration Source mA with
results without a calculator. simultaneous
Memory storage for up to eight calibration results, pressure measurement
return stored calibration data from the field for to conduct valve and I/P tests
later analysis. Support flow meter testing with
Frequency totalizer and frequency pulse train source frequency and counts per minute
mode for enhanced flowmeter testing. (CPM) functions
HART mode inserts 250 ohm resistor in mA Perform fast linearity tests with
measure and source for compatibility with HART auto step and auto ramp features
instrumentation. Three-year warranty
Integrated pressure switch test allows you to capture
the set, reset and deadband of a switch. Intrinsically safe version available
Custom RTD curves, add calibration constants for (see page 37)
certified RTD probes for enhanced temperature
measurement.
New voltage input protection design for improved
reliability.
Three-year warranty.
Simultaneous function Channel A Channel B
Specifications 726 and 725 Calibrators capability
24.000 mA dc M M or S
24.000 mA dc with 24 V M
Measure and source loop supply
General specifications 100.00 mV dc M or S
Functions Range or type Resolution Accuracy Notes
Storage temperature: 30.000 V dc measure M
Voltage 0 to 100 mV 0.01 mV 0.01 %, Max load, 1 mA
0 to 10 V (source) 0.01 V 0.02 % -20 C to 71 C 20.000 V dc measure M or S
0 to 20 V (source) 0.01 V Rdg + 2 LSD Operating temperature: 10.000 V dc source
0 to 30 V (measure) 0.01 V -10 C to 55 C 20.000 V dc source
mA 0 to 24 0.001 mA 0.01 %, Max load, 1000 W Relative humidity: 15 to 3200 Ohms M or S
0.02 % 90 % (10 C to 30 C); 5 to 4000 Ohms
Rdg + 2 LSD 75 % (30 C to 40 C); Thermocouple J, K, T, E, R, S, M or S
mV (TC -10.00 mV to .01 mV 0.01 %, 0.02 % 45 % (40 C to 50 C); B, M, L, U, N, XK, BP
terminals) +75.00 mV of range + 1 LSD 35 % (50 C to 55 C) RTD Cu 10, Ni120; Pt100 (392); M or S
Ohms 15 W to 3,200 W 0.01 W 0.10 W to 1.0 W Shock: 1 meter drop test Pt100 (JIS); Pt100, 200, 500,
5 W to 4,000 W to 0.1 W 0.015 % Safety: CSA C22.2 1000 (385), XK and BP
Hz - CPM 2.0 to 1,000 CPM 0.1 CPM 0.05 % Source; No. 1010.1:1992 Pressure (requires Fluke M M used
1 to 1000 Hz 1 Hz 0.05 % 5 V p-p EMC: EN50082-1:1992 and 700PXX Modules) as S
1.0 to 10.0 kHz 0.1 kHz 0.25 % 1 V to 20 V p-p EN55022:1994 Class B Frequency; 10 kHz; M or S
10.0 to 15.0 kHz 0.1 kHz 0.05 % squarewave, Size (HxWxD): 200 mm x (15 KHz 726)
-0.1 V offset 96 mm x 47 mm (7.9 in x
Loop supply 24 V dc N/A 10 % 3.8 in x 1.9 in) M = Measure, S = Source/Simulate
T/C J, K, T, E, L, N, U, XK 0.1 C, 0.1 F to 0.7 C Weight: 650 g (23 oz)
to 0.2 C Battery: Four AA alkaline
T/C B, R, S, BP 1 C, 1 F to 1.7 C batteries
to 1.2 C Battery life: 25 hours
RTDs Cu (10), Ni120 (672) 0.01 C, to 0.15 C typical Included accessories
Pt 100, 200, 500, 0.01 F
1000 (385) TL75 Test Leads, AC72 Test Clips,
Pt 100 (3916), 0.1 C, 0.1 F to 0.2 C one pair of stackable test leads,
Pt 100 (3926)
product overview manual (print)
Unique 726 specifications are bolded. and users manual in 14 languages
on CD-ROM.
Recommended accessories 726 and 725 Calibrators Ordering information
FLUKE-726 Precision Multifunction
Process Calibrator
FLUKE-725 Multifunction Process
Calibrator
FLUKE-724 Temperature Calibrator
Fluke-700PTP-1 C125 ToolPak 80PK-27 Fluke-700Pxx
Pneumatic Soft Carrying Meter Hanging Kit SureGrip Industrial Pressure Modules
(also see page 34)
Test Pump Case See page 63. Surface Temperature Probe See page 35.
See page 61. See page 60.

For more information, go to www.fluke.com/726 Process Calibration Tools 33


Fluke 712, 714 and 724
Temperature Calibrators
Accurate and rugged, T
 emperature calibration
temperature calibration tools See how Fluke
can help you
calibrate,
The Fluke 710 Series temperature calibrators deliver troubleshoot
outstanding performance, durability and reliability. And and verify the
with a push-button interface, similar to the multifunction most common
Fluke 740 Series Documenting Process Calibrators, the temperature
710 Series are easy to use. Each calibrator is EMI toler- devices, faster
ant, dust- and splash-resistant, and features a removable and easier.
battery door for quick battery changes.
Download
Fluke 712 RTD Calibrator this application
Compatible with pulsed current transmitters. note at
Measure temperature from an RTD probe. www.fluke.com/
Simulate RTD output. temp-cal
Operates with seven types of RTD.
Measure additional RTDs using ohms measurement
function.
Simulate additional RTDs using ohms source function.
F or C selectable. Fluke 724 Temperature
25 % stepping, auto-step and auto-ramp. Calibrator
Ramp and Step Ramp output functions. Source/measure TCs, RTDs,
volts and ohms.
Fluke 714 Thermocouple Calibrator Measure mA while supplying
Measure temperature from TC probes. loop power.
Simulate TC output. 25 % and 100 % stepping,
Operable with nine types of thermocouples. auto-step and auto ramp.
Calibrate linear TC transmitter with mV source function.
Selectable F or C.
25 % stepping, auto-step and auto-ramp.
Available as accessories: Fluke 700TC1 and TC2
Thermocouple Mini-plug Kits.
Ramp and Step Ramp output functions.

Specifications 712 and 714 Calibrators


Models Functions Range Resolution Accuracy Notes
Fluke 712 Measure/simulate RTD -200 C to 800 C 0.1 C, 0.1 F 0.2 C, 0.4 F Pt; 100 200 500
(Pt 100-385) (Pt 100-385) 1000 (385); Pt 100
(392); Pt 100 (392) JIS;
Ni 120 (672)
Measure/simulate 5 W to 4000 W 0.1 W 0.025 %
resistance
Fluke 714 Measure/simulate -200 C to 1800 C, 0.1 C or F 0.5 C, 0.8 F 9 TC types; J K T E R
thermocouple depending on type (1 C or F; BRS) (Type K) S B per NIST 175 and
(K, -200 C to ITS-90 L U per DIN
1370 C) 43710 and PTS-68
Measure/simulate mV -10 mV to 75 mV 0.01 mV 0.015 % +10 V
General specifications for all Fluke 712 through 718 calibrators.
Maximum voltage: 30 V. Non-operating temperature: -40 C to 60 C. Operating temperature: -10 C to 55 C.
Relative humidity: 95 % (10 C to 30 C); 75 % (30 C to 40 C); 45 % (40 C to 50 C); 35 % (50 C to 55 C).
Operating altitude: 3,000 m max. Shock: 1 m drop test. Vibration: Random, 2 g, 5-500 Hz.
Safety: CSA C22.2 No. 1010.1:1992. EMC: EN50082-1:1992 and EN55022:1994 Class B.
Size/weight (HxWxD) (712-717): 187 mm x 87 mm x 32 mm (7.35 in x 3.41 in x 1.25 in) 330 g (12 oz).
Size/weight (HxWxD) (712-717 with holster): 201 mm x 98 mm x 52 mm (7.93 in x 3.86 in x 2.06 in) 600 g (21 oz).
Size/weight (HxWxD) (718): 210 mm x 83 mm x 62 mm (8.25 in x 3.27 in x 2.44 in) 737 g (26 oz).
Size/weight (HxWxD) (718 with holster): 216 mm x 94 mm x 66 mm (8.50 in x 3.72 in x 2.60 in) 992 g (35 oz).
Power: 9 V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 .
Battery life: 4 to 20 hours, typical, depending on functions used.
Warranty: Three-years (one-year on pressure pump in Fluke 718).

Recommended accessories 712, 714 and 724 Calibrators Included accessories


Fluke 71X: Protective yellow hol-
ster with test lead storage, test leads
and alligator clips (excluding model
714), single 9 V alkaline battery and
instruction sheet (14 languages).
TL75 (712 and 724) C550 TL220 (712 and 724) C25 (712 and 714) 80PK-24 (714 and 724)
Fluke 724: TL75 Test Leads, AC72
Hard Point Tool Bag SureGrip Industrial Large Soft Case SureGrip Air Test Clips, one pair of stackable test
Test Lead Set See page 62. Test Lead Set See page 62. Temperature Probe
See page 54. See page 53. See page 60.
leads, product overview manual
(print) and users manual in 14
languages on CD-ROM.

Ordering information
FLUKE-712 RTD Calibrator
C101 (724) 80PK-3A (714, 724) ToolPak AC220
FLUKE-714 Themocouple Calibrator
Meter Hard Case Surface Probe Meter Hanging Kit SureGrip Alligator Clips FLUKE-724 Temperature Calibrator
See page 62. See page 60. See page 63. See page 54.

For more information, go to


34 Process Calibration Tools www.fluke.com/tempcal
Fluke 718 and 717
Pressure Calibrators Pressure
Enabled

Compact, professional, Pressure calibration with the


pressure calibration tools Fluke 718
New design pro-
tects on-board 0RESSURECALIBRATION
Fluke 718 Pressure Calibrators pump from fluid
WITHTHE&LUKE
.EWDESIGNPROTECTSON BOARD
PUMPFROMFLUIDDAMAGE

New! Self contained pressure calibrators up to


!PPLICATION.OTE

damage. This 0ROTECTYOURTOOLS

300 PSI with internal pump application note 0RESSURECALIBRATIONTYPICALLY


INVOLVESAPNEUMATICCALIBRATION
PUMPANDAPRESSURECALIBRA
TIONTOOLORREFERENCEGAUGE4HE

Compact size, lightweight.


PUMPAPPLIESPRESSURETOBOTH

explains how
THEDEVICEUNDERTEST$54 AND
THECALIBRATIONTOOLSEEFIGURE  6
4HETRICKISTHATBEFOREYOU 6
CANAPPLYPRESSUREWITHAPNEU
MATICHANDPUMP YOUABSOLUTELY

New built-in pressure switch test feature. to drain pres-


MUSTFIRSTDRAINALLCONDENSATE
ANDOILFROMTHELINES7HY)F
THERESOILORWATERTRAPPEDIN
THELINEWHENTHEPUMPISCON
NECTED THATFLUIDCANBEPULLED 2ED

Built-in pressure/vacuum hand pump, with vernier


BACKINTOTHEPUMPWHENTHE

sure lines safely


PRESSUREISRELEASED4HATCAN
EITHERCAUSECOSTLYDAMAGETOTHE "LACK
PUMP ORATTHEVERYLEASTFORCE
YOUTODISASSEMBLEANDCLEANTHE
PUMPBEFORERE USE

before calibra-
&IGURE4ODRAINPROCESSmUIDS CLOSE6ANDOPEN6BEFORECONNECTINGTHE#ALIBRATOR
&ORTHISREASON THEUPDATED

and bleed valve.


&LUKE0RESSURE#ALIBRA THECOMPLEXITYANDCOSTOFREPAIR ENTERINGTHEPUMPANDCAUSING
TORNOWCONTAINSANINNOVATIVE OFAPUMPFOULEDBYPROCESS DAMAGE4HESETWOCHECKVALVES
NEWPUMPDESIGNTHATISEASILY MEDIAISNORMALLYHIGHERTHANA ALLOWTHEBI DIRECTIONALFLOWOF
CLEANEDINTHEFIELDANDINHIBITS STANDALONEPUMP AIRINTOOROUTOFTHE


DAMAGEFROMPROCESSFLUIDS

tion, and how to


%VENAFTERDRAININGTHEPRO

Pressure and vacuum measurement to 0.05 % of full


5SINGTHEUPDATED CESSFLUIDFROMTHECALIBRATION
0NEUMATICPRESSURE #ALIBRATORPUMP PORTOFTHEDEVICEUNDERTEST
CALIBRATORSWITH MINUTEAMOUNTSOFPROCESS
INTEGRATEDTESTPUMPS 4HENEW&LUKEISAUNIQUELY
FLUIDSMAYOFTENSTILLBELURKING
PROTECTEDPNEUMATICPRESSURE
)NSTEADOFTHEPUMP PLUS BEHIND)NTHEEVENTTHESEFLUIDS

clean the pres-


CALIBRATORANDPUMP4HENEW
ENTERTHEPUMPCAVITIES THE

span, using an internal pressure sensor (dry air only).


CALIBRATORMETHODDESCRIBED PUMPDESIGNUSESPROTECTIVE
ABOVE MANYTECHNICIANSNOW NEWPUMPDESIGNENABLESQUICK
CHECKVALVESTHATALLOWAIRTO
USEAHANDHELDPNEUMATICPRES CLEANINGANDMAINTENANCE EVEN
PASSTHROUGHTHEPUMPFORCALI
SURECALIBRATORTHATINCLUDESAN INTHEFIELD
BRATIONBUTINHIBITSFLUIDSFROM
ONBOARDPNEUMATICPUMP MAR

sure pump on the


RYINGTWODEVICESINTOONEHANDY

Pressure measurement to 10,000 psi/700 bar using


INTEGRATEDTOOL7HILETHEINTE
GRATEDPUMPISMORECONVENIENT !IRFLOWTO
INPUT )NLET
ANDEASIERTOUSE ITISDOUBLY CONNECTOR
IMPORTANTTOMAKESUREPROCESS ANDVERNIER 4OPUMP
FLUIDSAREPROPERLYDRAINEDBEFORE ADJUSTMENT /UTLET

any of 29 Fluke 700Pxx Pressure Modules. new Fluke 718.


MAKINGACONNECTION"ECAUSE
THEPUMPITSELFNORMALLYNEEDS
TOBEREMOVEDFROMTHECALIBRA
TORBEFORECLEANING REBUILDINGOR &IGURE4HE&LUKEISDESIGNEDTOPROTECTTHEHANDPUMPANDSIMPLIFYMAINTENANCE
REPLACEMENTCANBEPERFORMED

Measure mA with 0.015 % accuracy and 0.001 mA Download


ii }>L>JviVL>

resolution, while providing 24 volt loop power supply. this application note at
18 inch NPT female pressure fitting. www.fluke.com/pressure-cal
Min/Max/Hold functions.
Intrinsically safe 718 version available (see page 37)

Fluke 717 Pressure Calibrators


Now with 9 ranges: 1, 30, 100, 300, 500, 1000, Pressure
1500, 3000 and 5000 psi Enabled

Measure pressure and vacuum to 0.05 % of full scale


Fluke Process
with internal sensor. Calibrators in
1/8 NPT pressure fitting this catalog
Compatible with non-corrosive gasses and liquids displaying
Measure pressure to 10,000 psi/69 mPa using one of the Pressure
Enabled symbol
29 Fluke 70Pxx Pressure Modules. display readings
Measure mA with 0.015 % accuracy and 0.001 mA from the 700
resolution, while providing 24 V loop power. Fluke 700 Series Series Pressure
New built-in pressure switch test feature. Pressure Modules
Modules.

Min/Max/Hold functions. 29 pressure modules


8 intrinsically safe pressure modules*
Ranges from 1.000 in H 0 2

(0.2491 kPa) to 10,000 psi


(68.948 MPa)
Specifications 717 and 718 Calibrators Gage, differential, dual (compound),
absolute, and vacuum modules
Models Range Resolution Comment Rugged cases protect the modules
717-1 +/- 1 psi, 27.5 in H20, +0.0001 psi, 0.0001 kPa, Fluke-718 dry air only and from harsh environments
718-1G (-7 - +7 kPa) 0.0001 in H20 includes on board pump
Full-accuracy performance from
717-30G -12 to + 30 psi, 0.001 psi, 0.001 kPa, 0.001 Fluke-718 dry air only and 0 C to 50 C
(-83 to 207 kPa) in H20 includes on board pump
718-30G* Pressure readings update twice per
717-100G -12 to + 100 psi, 0.01 psi, 0.01 kPa, 0.01 in H20 Fluke-718 dry air only and
(-83 to 690 kPa) includes on board pump
second, and may be displayed in
718-100G*
up to 11 different units
717-300G
718-300G*
-12 to +300 psi,
(-83 to +2070 kPa)
0.01 psi, 0.01 kPa, 0.01 in H20 Fluke-718 dry air only and
includes on board pump One-year warranty
717-500G 0-500 psi, 0-3450 kPa 0.01 psi, 0.1 kPa Compatible with non-corrosive *For use with 718Ex and 725Ex only
gases and fluids (see page 37 for more information).
717-1000G 0-1000 psi, 0-6900 kPa 0.01 psi, 0.1 kPa Compatible with non-corrosive
gases and fluids
717-1500G 0-1500 psi, 0-10342 kPa 0.1 psi, 1 kPa Compatible with non-corrosive Included accessories
gases and fluids
Fluke 718 and 717: Protective
717-3000G 0-3000 psi, 0-20700 kPa 0.1 psi, 1 kPa Compatible with non-corrosive
gases and fluids
yellow holster, test leads and
717-5000G 0-5000 psi, 0-34500 kPa 0.1 psi, 1 kPa Compatible with non-corrosive
alligator clips, single 9 V alkaline
gases and fluids battery (two 9 V batteries in 718)
Pressure accuracy 0.05 % of range and instructions.
mA measurement 0-24 mA range 0.001 mA resolution Accuracy: 0.015 % + 1 count
Loop power 24 V dc Accuracy: 10 % Ordering information
*Intrinsically safe models available.
FLUKE-718 30US Pressure Calibrator
Warranty: Three-year on calibrator, one-year on pump FLUKE-718 100US Pressure Calibrator
FLUKE-718 1G Pressure Calibrator
Recommended accessories 717 and 718 Calibrators FLUKE-718 300G Pressure Calibrator
FLUKE-717 30G Pressure Calibrator
FLUKE-717 100G Pressure Calibrator
FLUKE-717 1G Pressure Calibrator
FLUKE-717 300G Pressure Calibrator
FLUKE-717 500G Pressure Calibrator
700ILF 700LTP-1 TL220 C116 700HTP-1 FLUKE-717 1000G Pressure Calibrator
In-Line Filter Low Pressure SureGrip Industrial Large Soft Case Hydraulic Test Pump FLUKE-717 1500G Pressure Calibrator
See page 61. Test Pump Test Lead Set See page 62. See page 61. FLUKE-717 3000G Pressure Calibrator
See page 61. See page 53.
FLUKE-717 5000G Pressure Calibrator

For more information, go to www.fluke.com/pressure Process Calibration Tools 35


Fluke 715, 707 and
705 Loop Calibrators
Troubleshooting
Complete family of volt/mA calibrators process loops
In process
systems, prob-
Fluke 707 and 705 lems with
Two powerful models to choose from the loop can
Innovative output adjustment dial on 707 provides bring things to
1 A and 100 A resolution and one-hand operation. a screeching
Large display and simple interface for ease of use. halt. In this
Simultaneous mA and % readout for quick, easy application
interpretation of readings. note, find out
mA accuracy of 0.015 % on the Fluke 707 and 0.02 % how to use
on the 705. Fluke test tools
HART mode on 707 connects 250 ohm resistor in to identify
series with 24 V loop for compatibility with HART current loop
communicators. problems such
Push button 25 % steps for fast, easy linearity checks. as noise,
Span Check for fast confirmation of zero and span. ripple and drift.
Selectable slow and fast linear step ramp provide Download this application note at
ramping outputs for valve slewing, remote testing www.fluke.com/process-loops
and loop functional tests.
24 V internal loop supply, so you can power and read
a transmitter at the same time without carrying a DMM.
0 mA to 20 mA or 4 mA to 20 mA default start Fluke 715 Volt/mA Calibrator
up modes. Source voltage to 200 mV or 20 V.
Intrinsically safe 707 version available (see page 37). Measure loop current (0 to 20 mA,
4 to 20 mA) signals with 0.01 %
accuracy and 1 A resolution.
Measure voltage output process
signals from PLCs, transmitters.
Source or simulate 24 mA
loop current.
24 V loop supply with simultaneous
current measurement.
Specifications 715, 707 and 705 Ramp and Step Ramp output functions.

Functions Fluke 705 and 707 Fluke 715


Voltage measurement
Range 0 V to 28 V 0 mV to 200 mV 0 V to 25 V
Resolution 1 mV 10 V 1 mV
Accuracy 705: 0.025 % Rdg + 1 LSD 707, 0.01 % Rdg + 2 LSD
707Ex: 0.015 % Rdg + 2 LSD
Current measurement
Range 0 mA to 24 mA 0 mA to 24 mA
Resolution 0.001 mA 0.001 mA
Accuracy 705: 0.02 % Rdg + 2 LSD 707, 0.01 % + 2 LSD
707Ex: 0.015 % Rdg + 2 LSD
Current sourcing
Range 0 mA to 20 mA or 4 mA to 20 mA 1
0 mA to 20 mA or 4 mA to 20 mA
Accuracy 705: 0.025 % Rdg + 2 LSD 707, 0.01 % Rdg + 2 LSD
707Ex: 0.015 % Rdg + 2 LSD
Drive capability 705: 1000 W @ 24 mA 707: 1200 W @ 1000 W @ 24 mA
24 mA 707Ex: 700 W @ 20 mA
Loop power while measuring mA 24 V 24 V
Voltage sourcing 0 mV to 200 mV or 0 V to 20 V
Display current and % of span Yes mA or %
Auto step, auto ramp Yes Yes
Span Check Yes Yes
Battery life 18 hours typical, at 12 mA 18 hours typical, at 12 mA
Included accessories
Warranty Three-year warranty
Fluke 715: Protective yellow hol-
Will over-range to 24 mA. ster, test leads and alligator clips,
single 9 V alkaline battery and
instruction sheet (14 languages).
Recommended accessories 715, 707, 707Ex and 705 Calibrators Fluke 705, 707 and 707Ex:
Protective holster, TL75 Test Leads,
AC72 Test Clips and instruction
sheet (14 languages).

Ordering information
TL28A TL220 C25 C550 PV350 FLUKE-715 Volt/mA Calibrator
Heavy Duty SureGrip Industrial Large Soft Case Tool Bag Pressure Vacuum FLUKE-707 Loop Calibrator
Test Lead Set Test Lead Set See page 62. See page 62. Module
See page 54. See page 53. See page 57. FLUKE-707Ex IS Loop Calibrator
FLUKE-705 Loop Calibrator

For more information, go to


36 Process Calibration Tools www.fluke.com/loop
Intrinsically Safe
Products
Calibrators, thermometers and multimeters Making sense of intrinsic
designed to intrinsic safety standards safety and intrinsically
safe tools
Want to know
What is Intrinsically Safe? what industries
Intrinsic safety is a protection method employed in potentially explosive atmospheres. intrinsically safe
Devices that are certified as intrinsically safe are designed to be unable to release products are
sufficient energy, by either thermal or electrical means, to cause ignition of flammable designed for?
material (gas or dust/particulates). Want to know
There are no global intrinsically safe standards or certifications, but there are why intrinsic
organizations that influence directives in certain world geographies. safety is so
important? Want
Factory Mutual to make sense
In the United States, Factory Mutual Research, managed by Factory of the product
Mutual (FM) Global, is a non-profit scientific and testing organization ratings and
that has tested and certified over 40,000 products in the last 165 classifications?
years. FM Research has set certification guidelines for equipment used
in potentially explosive atmospheres. Go to www.
fluke.com/ex
Canadian Standards Association (CSA)
Accreditation body for North American regulations, based in
Toronto, Canada.
Fluke 68IS Intrinsically Safe
ATEX Infrared Thermometer
The primary intrinsically safe standard, which has been set in the Laser guided sighting system
European Union with the Directive 94/9/EC, commonly called ATEX for easy targeting with
(Atmosphres Explosibles), French for explosive atmospheres. 1 % accuracy.
For more information and detailed specifications, turn to the 12-point data logging.
corresponding non-intrinsically safe product pages (Fluke 707, 718, Advanced optics to
725, 574, 68) or go to www.fluke.com/ex. measure smaller targets
at greater distances.
For
Adjustable emissivity for
additional more accurate temperature
North American product measurements.
Fluke products ATEX certified Certification detail Selectable Max, Min, Dif
87V Ex: Intrinsically and Avg functions that
Safe True-rms Multimeter display values instantly
II 2 G EEx ia IIC T4 See page 8 with Hi/Lo Alarm.
Expanded measurement
range up to 760 C (1400 F).
RTD probe accessory included
707Ex: Intrinsically
Safe mA Calibrator
for dual contact and non-contact
temperature measurements.
II 2 G EEx ia IIC T4 N.I. Class I, Div 2,
See page 36
Class I, Division 1, Groups A, B, C,
Groups A-D T4 D Class I, Zone 0, AEx ia IIC, T4 at
50 C when used with 9 V alkaline
718Ex: Intrinsically battery.
Safe Pressure Calibrator Not available for purchase in Europe.
II 1 G EEx ia IIC T4 I.S. Class I, Div 1, See page 35
Groups A-D T4
Ordering information
725Ex: Intrinsically Safe
FLUKE-87V Ex IS True-rms
Multifunction Calibrator Multimeter
See page 33
FLUKE-707Ex IS Loop
II 1 G EEx ia IIB 171 C I.S. Class I, Div 1, Calibrator
Groups B-D, 171 C
FLUKE-718Ex IS Pressure
Calibrator
700PEx: Intrinsically FLUKE-725Ex IS Multifuction
Safe Pressure Modules
Process Calibrator
II 1 G EEx ia IIC T4 I.S. Class I, Div 1, See page 35 FLUKE-700PEx Pressure Modules
Groups A-D T4 (700P01Ex,
700P05Ex,
Fluke 574-NI Nonincendive 700P06Ex,
Infrared Thermometer 700P09Ex,
See page 39 700P24Ex,
Class I, Division 2, 700P27Ex,
Groups A, B, C, D;
Class I, Zone 2 IIC
700P29Ex and
700PA4Ex)
Fluke 68IS Intrinsically Safe FLUKE-574-NI Precision Infrared
Infrared Thermometer
Thermometer w/
Class I, Division 1, See page 38 Logging SW
Groups A, B, C, D Nonincendive
Class I, Zone 0 AEx FLUKE-68IS Infrared
ia IIC
Thermometer
Intrinsically Safe
For more information, go to www.fluke.com/ex Intrinsically Safe Products 37
Fluke 54 Series II
Thermometer
Fluke 63, 66, and 68
Lab accuracy in a field thermometer Infrared Thermometers
Infrared thermometers are
perfect for measuring hot,
The Fluke 51, 52, 53 and 54 Series II Thermometers offer moving, electrically
high accuracy with fast response times to quickly capture energized, and hard-
your measurement and show trends. Choose from four models to-reach objects and
to get the functionality, thermocouple support and data logging equipment.
you need. Wide temperature
range and quick
All models offer: response time.
Laboratory accuracy: (0.05 % + 0.3 C). Choice of D:S
Large backlit dual display presents all the information 12:1 (63) 30:1 (66)
you need at a glance. 50:1 (68).
Min, Max, and Avgwith time referencescaptures Laser sighting.
major events. Adjustable emissivity
Electronic Offset function maximizes overall accuracy by (66/68) for more
allowing you to compensate for thermocouple errors. accuracy.
Supports a wide range of thermocouple types. Two-year
Temperatures displayed in C, F, or Kelvin (K). warranty.
Splash and dust resistant case. Intrinsically safe Fluke 68
Sleep mode to increase battery life (typical 1000-hour life). version available (see page 37).
Battery door allows easy battery replacement without
breaking the calibration seal.

Powerful data logging capabilities Fluke 61 Infrared


The Fluke 53 and 54 Series II can log up to 500 points of
data to internal memory. Thermometers
User-adjustable recording intervals. Easy to use one
Real-time clock captures the exact time of day button operation.
of events. Easy targeting with
Recall function allows logged data to be easily reviewed bright laser.
on the meter display. Shock-absorbing
For further analysis and graphing, data can be molding increases
exported to optional FlukeView PC software using ruggedness.
the thermometers IR communication port. Two-year conditional
warranty.
Temperature
measurement range
up to 275 C (525 F).
8:1 optics.
Accurate to within
2 % of reading or 2 C,
Specifications 51, 52, 53 and 54 Series II which ever is greater.

Features 51 52 53 54
Thermocouple types K,J,T,E K,J,T,E K,J,T,E,N,R,S K,J,T,E,N,R,S Included accessories
Number of inputs Single Dual Single Dual Fluke 50 Series II: 80PK-1 Bead
Time stamp Relative time Relative time Time of day Time of day Thermocouple(s), batteries, overview
Temperature measurement accuracy
(for temperatures above -100 C)
Type J,K,T,E,N: [0.05 % + 0.3 C (0.5 F)] Type R,S: [0.05 % + 0.4 C (0.7 F)] manual and instructional guide on
Measurement range -250 C (-418 F) to 1767 C (3212 F)
CD-ROM.
(depending on thermocouple type) Fluke 63, 66, 68: Carrying case,
Display resolution 0.1 C/F/K < 1000 , 1 C/F/K 1000
users manual, 9 V battery.
Operating temperature -10 C to 50 C (14 F to 122 F)
Storage temperature -40 C to 60 C (-40 F to 140 F) Fluke 61: Instruction sheet and 9 V
Humidity 0 % to 90 %; 0 C to 35 C (32 F to 95 F), 0 % to 70 %; battery.
0 C to 50 C (32 F to 122 F)
Weight 400 g (14 oz) Ordering information
Size (HxWxD) 17.3 cm x 8.6 cm x 3.8 cm (6.8 in x 3.4 in x 1.5 in) FLUKE-51-2 Digital Thermometer,
Battery Three AA batteries; typical 1000-hour life Single Input
Warranty Three-years FLUKE-52-2 Digital Thermometer,
Dual Input
Recommended accessories 51, 52, 53 and 54 Series II Thermometers FLUKE-53-2 Datalogging
Thermometer,
Single Input
FLUKE-54-2 Datalogging
Thermometer,
Dual Input
TPak 80PK-8 80PK-22 80PK-25 FVF-SC1
FLUKE-63 Infrared Thermometer
ToolPak Meter Pipe Clamp SureGrip Immersion SureGrip Piercing FlukeView Forms FLUKE-66 Infrared Thermometer
Hanging Kit Temperature Probe Temperature Probe Temperature Probe Software FLUKE-68 Infrared Thermometer
See page 63. See page 60. See page 60. See page 60. See page 57.
FLUKE-68IS Intrinsically Safe
Infrared Thermometer
FLUKE-61 Infrared Thermometer

For more information, go to


38 Thermometers www.fluke.com/thermometers
Fluke 560 Series
Infrared Thermometers
Go beyond other IR thermometers Fluke 62 Mini Infrared
with more applications Thermometer
Temperature measurement range
up to 500 C (932 F).
Fluke 566 and 568 IR and contact thermometers 10:1 optics.
Just when you thought advanced IR temperature Accurate to within
measurement should be easier! With a straight- 1.5 % of reading
forward user interface and soft-key menus, the or 1.5 C.
Fluke 566 and 568 make even complex measure- Max temperature
ments easy. With just a few pushes of a button you display.
can easily adjust emissivity, start data logging, or Laser sighting.
turn on and off alarms. With a rugged, easy-to-use Backlit display.
design, the Fluke 566 and 568 can stand up to tough Two-year
industrial, electrical, and mechanical environments. conditional
Measure up to 800 C (1470 F). warranty.
Easily access advanced features with the
soft-key buttons and graphical display.
Measure smaller objects from further away.
Compatibility with most type-K thermocouples. Fluke 561 Infrared and
Confidently measure more surfaces, with adjustable emissivity and Contact Thermometer
built-in materials table. The Fluke 561 combines
Log and download measurements for reporting (568). the temperature
Two levels of backlight. measurement functions
Audible and visual alarms alert you to measurements outside of that professionals
set limits. need for most HVAC
Min, Max, Avg, and Dif functions. and industrial jobs,
Includes KTC Bead Probe. all in one tool.
1 % measurement accuracy. Velcro pipe probe
Versatile interface with six languages. for superheat and
sub-cooling and
other contact
and ambient
Specifications Infrared Thermometers measurements.
Min, Max and
Models Fluke 561 Fluke 566 Fluke 568 Fluke 68IS Fluke 62
Dif functions
Infrared temperature -40 C to 535 C -40 C to 650 C -40 C to 800 C -32 C to 760 C -30 C to 500 C
range (-40 F to 1022 F) (-40 F to 1200 F) (-40 F to 1470 F) (-25 F to 1400 F) (-20 F to 932 F) help you quickly
Accuracy greater of 1 % or 1 C (2 F) greater of 1 % greater of 1.5 % identify problems.
Distance to Spot (D:S) 12:1 30:1 50:1
or 1 C (2 F)
50:1
or 1 C (2 F)
10:1
Scan large areas or small objects
Sighting Laser point
quickly and efficiently.
Typical distance Up to 2.5 m (7 ft) Up to 4.5 m (15 ft) Up to 7.5 m (25 ft) Up to 7.5 m (25 ft) Up to 2 m (6 ft)
to target
Probe type Thermocouple K RTD
Contact temperature -40 C to 550 C -270 C to 1372 C -40 C to 260 C
range (-40 F to 1022 F) (-454 F to 2501 F) (-40 F to 500 F)
Number of on-board 20 99 12
memory locations
PC download and Yes,
software with FlukeView
Forms
Soft-key feature Yes
menu navigaton
Min/Max/Avg/Dif Min/Max/Dif Min/Max/Avg/Dif Min/Max/Avg/Dif Max Included accessories
English, French, Chinese, Yes
Spanish, Portuguese, Fluke 561: Thermocouple K-type
German user interface
Velcro pipe probe, carrying case,
Material type Hi/Med/Lo Material table or 0.1 to 1.00 by 0.01 0.1 to 1.00 by 0.01 Preset to 0.95
adjustment (emissivity) users manual, two AA batteries.
Two levels of backlight Yes
Fluke 566: Thermocouple K-type
High and low alarms High and low alarms High and low alarms
bead probe, carrying case, users
Hazardous location FM approved
approval intrinsically safe manual and quickstart guide, two AA
Hands-free logging Yes batteries.
Battery 2 AA 9V
Fluke 568: USB cable, FlukeView
Included case Hard case Hard case Soft case
(except 561/R and Hard case Forms software, thermocouple K-type
561/P)
bead probe, carrying case, users
Warranty Two-years
manual and quickstart guide, two AA
batteries.
Recommended accessories Infrared Thermometers Fluke 62: Storage pouch and
instruction sheet.

Ordering information
FLUKE-561 Infrared Thermometer
FLUKE-566 Infrared Thermometer
80PK-11 LVD1 C101 FLUKE-568 Infrared Thermometer
Pipe Clamp Probe Volt Light Deluxe FLUKE-62 Mini Infrared
(all models) (all models) Hard Case
See page 60. See page 56. See page 62. Thermometer

For more information, go to www.fluke.com/thermometers Thermometers 39


Fluke 570 Series
Infrared Thermometers
The predictive maintenance 574-NI
professionals precision diagnostic tool Nonincendive
Thermometer
When safety is a
The Fluke 572, 574 and 576 non-contact thermometers concern and data
are ideal professional diagnostic tools for maintenance logging and
professionals requiring the most accurate temperature read- downloading are
ings at all distances. Predictive maintenance professionals required, the Fluke
requiring analysis and documentation use the 574 or 576 574 Nonincendive (NI) thermom-
models, with 100-point data logging and digital photographs eter is the product to choose. It
(576 only) with the included software for graphing and has the same great features as the
analysis for follow-up reporting and documentation. standard 574 model thermometers
Backlit display for poorly lit areas. with the extra confidence of a
Displays last ten temperature readings on bar graph for easy reference. Factory Mutual approval for use in
Enhanced optics (distance to spot ratio up to 60:1) allow measurements hazardous environments.
of smaller objects from farther away. Class I, Division 2, Groups A, B, C, D: Class I,
Coaxial three-dot laser sighting system highlights the true Zone 2 IIC; T4 Ta=50 C when used with 1.5 V
diameter of measurement spots at all distances. alkaline batteries.
Adjustable emissivity setting (all models) and 30 pre-set
common material values (574, 576) for more accurate Fluke 576 Photographic
measurements. Non-contact Thermometer
100-data point logging for documentation (574, 576). The Fluke 576 thermometer mea-
Customizable log names, alarms, and emissivity sures temperature while digitally
values for personalized measurements (574, 576). photographing the measured area
Software to log, graph, and analyze temperature and its surroundings. The 576
data via RS-232 (574) connection or USB allows you to:
connection (576, includes photo viewing feature). Ensure consistency of repeated
Instantly captures photographs of measurement measurements by using prior
locations along with temperature and date-time photos as a reference.
information for improved documentation and Position the laser sighting to
maintenance follow-up (576). assure the measurement area is
Close-focus option available for specialized, the same.
small target applications. Create customized company
Durable hard plastic storage case. reports with the software, data
and photos, using standard
Windows programs.

Specifications 572, 574 and 576 IRTs Included accessories


2 AA batteries, operators guide
Models Fluke 572 Fluke 574 Fluke 574-NI Fluke 576 (on CD), durable hard case, thermo-
Temperature range -30 C to 900 C (-25 F to 1600 F) couple K probe (574, 576), power
D:S (Distance to Spot size) 60:1 [50:1 with close focus option (close focus not available with NI model)] supply (574), RS-232 data cable
Laser sighting 3-dot, coaxial, extra-bright
(574), USB 1.1 cable (576), data
Emissivity Adjustable Adjustable, plus table of 30 preset values
graphing, storage and analysis soft-
0.75 % of reading or ( 0.75 C ( 1.5 F) whichever is greater
Accuracy
(assumes ambient operating temperature of 23 C [73 F]) ware on CD-ROM (574, 576).
Response time 250 mSec
Display hold (7 seconds) Yes Ordering information
LCD backlit Yes FLUKE-572 Precision Infrared
Max, Min temperatures Yes Thermometer
Dif, Avg temperatures No Yes Yes Yes FLUKE-572-CF Precision Infrared
Recall last reading Yes Thermometer with
Audible/visible Hi alarm Yes Close Focus Option
Audible/visible Lo alarm No Yes Yes Yes FLUKE-574 Precision Infrared
Bar graph display Yes Thermometer
100 points data logging No Yes Yes Yes w/Logging SW
Data graphing software No Yes Yes Yes FLUKE-574-NI Precision Infrared
(Windows 2000, XP compatible)
Photo viewing software (Windows No No No Yes
Thermometer
2000, XP, NT compatible) w/Logging SW
26 images (640 x 480 pixel) No No No Yes Nonincendive
100 images (320 x 240 pixel) No No No Yes FLUKE-574-CF Precision Infrared
Image file format (.jpg) No No No Yes Thermometer
Protective hard case Yes w/Logging SW
Weight 472 g (1 lb, 1 oz) 480 g (1 lb, 1 oz) 480 g (1 lb, 1 oz) 580 g (1 lb, 1 oz)
Close Focus
Dimensions 16.7 cm x 5 cm x 19.8 cm (6.58 in x 1.97 in x 7.80 in) 16.7 cm x 5 cm x
23.8 cm (6.58 in x FLUKE-576 Precision,
1.97 in x 9.57 in) Photographic
Power 2 AA batteries 2 AA batteries/ 2 AA batteries/ 2 AA batteries/ Infrared
AC adapter AC adapter USB
Thermometer
Warranty Two-years, conditional
Additional options/accessories Nylon holster, NIST Nylon holster,
w/Logging SW
traceable calibration NIST traceable calibration certificate, FLUKE-576-CF Precision,
certificate analog cable Photographic
Infrared
Thermometer
w/Logging SW
Close Focus
For more information, go to
40 Thermometers www.fluke.com/thermometers
Find it, fix it, fast with
Fluke Thermal Imaging
Typical thermal imaging
The versatility of thermal imaging applications

Thermal imaging is a non-contact


technology that measures infrared
wavelengths to determine temperatures
from a safe distance.
Thermal images are displayed using
different intensities and colors to
represent different temperatures, making Electric motors and pumps
it easy to scan surfaces and identify Hot spots may be an early indicator
temperature differences. Hot or cool of motor winding problems. Elevated
areas or changes in temperature often temperatures can damage winding
indicate a problem. insulation, resulting in operational
Fluke Ti25 Until recently, thermal imaging was inefficiencies and premature motor
complex and expensive. Fortunately, failure. An overheated motor may be
recent advances have lowered costs an indication of an underrated motor
and made imagers easier to use... and in the application, insufficient cooling
rugged enough to use as an everyday or electrical power problems.
troubleshooting tool.

Fluke Ti40FT, Ti45FT,


Ti50FT, Ti55FT

Bus bars and fuse boxes


Temperature differences between
phases may indicate unbalanced
IR-Fusion Technology loads, harmonics, component
Infrared and visual images fused together in problems, bad connections or
one imageon camera and in software bad wiring. These conditions can
result in increased energy cost and
See things both ways! Infrared and visual Technology, only available from Fluke, can damage cables or machines
(visible light) images fused together com- simultaneously captures a digital photo and or possibly cause fire. Even small
municate critical information faster and the infrared image and fuses them together temperature differences between
easiertraditional infrared images are no on the imager screen, taking the mystery phases should be investigated to
longer enough. Patent pending IR-Fusion out of IR image analysis. determine the root cause.

Five IR-Fusion modes


Full IR Detect the smallest temperature
variations to track down the origin of prob-
lems and fully document the extent of the
problem. Full IR images are automatically
linked to full visual images.
Full IR Picture-in-Picture Create an IR Rotating machinery
window surrounded by a visual (visible Bearings showing an increased
light) frame to easily identify thermal temperature are an indication that
anomalies, while maintaining a frame of either the quality of the lubricant
reference with your surroundings. is deteriorating or there is poor
Alpha or Automatic Blending Combine a alignment between the motor and
visual and infrared image together to create shaft. These problems can cause the
Picture in Picture a single image with enhanced detail that bearings to fail, or a motor or pump
will help precisely locate problems. to overheat.

IR/Visible Alarm Display temperatures


that fall above, below, or in between a
specified range as IR image, leaving the
rest of the scene as a fully visual image
(Ti55FT and T145FT models only).
Alpha Blending Full Visible Light A bright, detailed
pixel-for-pixel reference image of subject
areas for documentation and reporting.
To request more information,
*While some viewing modes are not included
onboard every model, all are available for view-
or a demonstration, or to order,
ing and analysis in the included free SmartView call 1-800-760-4523 (U.S. only),
software. all other regions 1-425-446-4620.

IR/Visible Alarm

For more information, go to www.fluke.com/thermal_imaging Thermal Imaging 41


Ti25 and Ti10
Thermal Imagers
The perfect thermal imagers for Fluke Ti20
everyday troubleshooting and maintenance Thermal Imager
Everything needed for fast and
easy inspection routing
The perfect tools to add to your problem solving arsenal. Built The unbeatable solution for
for tough work environments, these high-performance, fully preventive and entry-level predictive
radiometric imagers are ideal for troubleshooting electrical maintenance.
systems, electro-mechanical equipment, process equipment, Fast and easy inspection routing.
HVAC/R equipment and others. Plan your equipment inspection
Enhanced problem detection and analysis capabilities route, load it into the imager once
with patent-pending IR-Fusion Technologyonly available and then follow the easy, on-
from Fluke. imager location instructions each
Fluke Ti25 Optimized for field use in harsh work environments. time you perform inspections.
Engineered and tested to withstand a 2 meter (6.5 ft) drop Complete imaging solution. The
Withstands dust and watertested to an IP54 rating Ti20 is packaged with all neces-
Innovative protective lens cover protects the lens when sary accessories including unlim-
not in use ited use InsideIR companion
Delivers the clear, crisp images needed to find problems fast software and a training CD to get
Identify even small temperature differences that could you up and running right away.
indicate problems with excellent thermal sensitivity (NETD) Designed for
Even the smallest details become visible with the large, industrial use.
widescreen full color LCD display Rugged Fluke
Intuitive, three-button menu is easy to use... simply navigate construction;
Fluke Ti10 with the push of a thumb. IP54-rated for
No need to carry pen and paperrecord findings by use in harsh
speaking into the cameracomments are saved with the work environments.
image (Ti25 only). Easy image cap-
Store more than 3,000 screen images (.bmp format) or 1,200 ture. Just point,
IR-Fusion images on included 2 GB SD memory card. focus and pull the
trigger!
See page 41 to find out the power of
IR-Fusion Technologyonly available from Fluke.

Specifications Ti25 and Ti10 Imagers


Features Ti25 Ti10
Temperature measurement range -20 C to +350 C (-4 F to + 662 F) -20 C to +250 C (-4 F to + 482 F)
(not calibrated below -10 C) (two ranges)
Accuracy 2 C or 2 % (whichever is greater) 5 C or 5 % (whichever is greater)
Field of view 23 x 17
Spatial resolution (IFOV) 2.5 mRad
Minimum focus distance Thermal lens: 15 cm (6 in)
Visible (visual) light lens: 46 cm (18 in)
Included accessories
Image frequency 9 Hz refresh rate
Fluke Ti25/Ti10: Thermal imaging
Detector type 160 X 120 focal plane array, uncooled microbolometer
camera w/20 mm lens, ac power
Infrared lens type 20 mm F = 0.8 lens supply/battery charger (including
Thermal sensitivity (NETD) 0.1 C at 30 C (100 mK) 0.2 C at 30 C (200 mK) mains adapters), SD memory card,
Visual camera 640 x 480 resolution SD card reader (USB), SmartView
Palettes Ironbow, blue-red, high contrast, Ironbow, blue-red, high contrast, gray software, rugged hard carrying
amber, hot metal, gray case, soft transport bag, hand strap,
IR-Fusion information Full infrared with Max, Mid, or Min Full infrared or picture-in-picture
automatic blending; and picture-in-picture
users manual, warranty registra-
with Max, Mid, or Min automatic blending tion card.
(Visual and IR blending)
Voice annotation 60 seconds maximum recording time per image Fluke Ti20: Thermal imaging
Storage medium SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual camera, InsideIR software, USB
images each with 60 seconds voice annotations or 3000 basic (.bmp) IR images) communication cable, hard carrying
File formats Non-radiometric (.bmp) or fully-radiometric (.is2) case, soft-sided carrying case, wrist
No analysis software required for non-radiometric (.bmp) files
Software SmartView full analysis and reporting software included
strap, 2 rechargeable battery packs,
Power Battery: Internal rechargeable battery pack (included)
one 1 AA battery carrier, training
Battery life: Three to four hours continuous use (assumes 50 % brightness of LCD) materials and getting started guide.
Battery charge time using ac adapter/charger and dc car charger: Two hours for full charge
AC operation/charging AC adapter/charger (110 V ac to 220 V ac, 50 Hz to 60 Hz). Charges battery while Ordering information
imager is operating. Universal ac mains adapters included.
FLK-Ti25 9HZ Thermal Imager
IP rating IP54
Warranty Two-years
FLK-Ti10 9HZ Thermal Imager
FLUKE-Ti20 US Thermal Imager
North America
Recommended accessories Ti25, Ti10, and Ti20 Thermal Imagers FLUKE-Ti20 INT Thermal Imager
Ampac
FLUKE-Ti20 INT/9 Thermal Imager
Ampac 9 Hz

Ti20-Visor Ti30-TBP Ti-CAR CHARGER


Sun Visor Rechargeable Battery Pack Car Charger
(for use with Ti20 Thermal Imager)

For more information, go to


42 Thermal Imaging www.fluke.com/thermal_imaging
Ti40FT and Ti50FT Series IR
FlexCam Thermal Imagers
The thermal imagers for Fluke SmartView IR
professionals demanding the best analysis and reporting
software
Fluke SmartView is included with
Find problems faster with all Fluke thermal imager models
Fluke thermal imagers. except the Ti20 (Ti20 includes
Reduce costs and maximize uptime Inside-IR software). This power-
with our complete range of imaging ful software allows you to analyze
solutions. They combine the larg- IR images in-depth, including any
est, sharpest images in the industry temperature value in the picture, as
with innovative, easy-to-use fea- well as change IR-Fusion blending,
Fluke Ti40FT, Ti45FT,
Ti50FT, Ti55FT tures. Reveal more with IR Fusion add notes to images, and create
Technology, now included on all reports. The software is easy to use,
models (excluding Ti20), merging yet delivers high performance for
See page 41 to find out advanced analysis.
the power of IR-Fusion infrared and visible light images in
Technologyonly one display. Fluke puts powerful Image viewing and editing.
available from Fluke. technology within your reach. Extensive annotation possibilities.
Detail analysis and total image
control.
Simplified report generation.

Specifications Ti40FT and Ti50FT Imagers


Functions Fluke Ti40FT Fluke Ti45FT Fluke Ti50FT Fluke Ti55FT
Field of view (FOV)* 23 horizontal x 17 vertical
Spatial resolution (IFOV)* 2.60 mrad 1.30 mrad
Min focus distance* 0.15 m
Thermal sensitivity (NETD) at 30 C 0.09 C 0.08 C 0.07 C 0.05 C
Detector data acquisition/image frequency 30 Hz/30 Hz 60 Hz/60 Hz
Detector size 160 x 120 320 x 240
Calibrated temperature range -20 C to 350 C -20 C to 600 C -20 C to 350 C -20 C to 600 C
1200 C High temperature option
Accuracy 2 C or 2 % (whichever is greater)
Digital display 5 large high-resolution backlight LCD
Video output RS170 EIA/NTSC or CCIR/PAL composite video
Palettes Grayscale, grayscale inverted, blue red, high contrast, hot metal,
ironbow, amber, amber inverted
Storage medium Compact flash card (512Mb) stores over 1000 IR images
File formats supported 14 bit measurement data included. Images: bmp, gif, jpg, png, tiff;
Data formats: comma separated (csv), tab separated (txt)
Interface Compact flash card reader included
Included software SmartView: Full analysis and reporting software
Warranty Two-years
Battery life: Two hours continuous operation
Water and dust resistant: IP54
Size (HxWxD): 162 mm x 262 mm x 101 mm (6.378 in x 10.315 in x 3.9764 in)
Weight: 1.85 kg (4.07 lb)
Included accessories
AC adapter, video cable, 512 MB
Features Ti40FT and Ti50FT Imagers compact flash card, compact flash
card reader and USB cable, PCMCIA
Features Ti40FT Ti45FT Ti50FT Ti55FT compact flash card adapter,
180 articulating flexible lens to view images in every situation SmartView reporting and analysis
Choice of 3 interchangeable lenses to cover every application* software on CD-ROM, two recharge-
Large 5 inch high contrast color LCD for a clear picture independent of
able battery packs, battery charger,
lighting conditions
neck strap, heavy duty carrying case
Fully radiometric for detailed temperature analysis and tracking
SmartFocus for best image quality and accurate temperature measurements
and users manual on CD-ROM.

Windows CE based menu structure for ease of use
Personalized instrument set-up for multiple use
Ordering information
CompactFlash memory cards to store over 1000 IR images plus fully FLK-Ti40FT-20 IR FlexCam

radiometric temperature data Thermal Imager
SmartView reporting and analysis software included FLK-Ti45FT-20 IR FlexCam
AutoCapture for making intermittent problems visible Thermal Imager
On-board analysis functions FLK-Ti50FT-20 IR FlexCam
User defined text annotations for simplified reporting Thermal Imager
*Additional lenses must be ordered at time of imager purchase. FLK-Ti55FT-20 IR FlexCam
Thermal Imager
Recommended accessories Ti40FT and Ti50FT Imagers
*Optional lenses on Ti4X/5XFT models
are available at time of order consult
the Fluke web for details.

103232 104543 Ti-SBC Ti-SBP


Anti-glare Hood Car Charger Battery Charger Rechargeable Battery Pack

For more information, go to www.fluke.com/thermal_imaging Thermal Imaging 43


Fluke TiR1/TiR
Thermal Imagers
Optimized for building inspection, restoration, Typical thermal imaging
remediation and roofing applications building applications
Thermal imaging is an efficient,
non-destructive testing method for
The new Fluke TiR1 and TiR Thermal Imagers are the perfect performing money-saving energy
imagers for any building application. audits and detecting problems
Enhanced problem detection and analysis capabilities such as:
with patent-pending IR-Fusion Technologyonly available Moisture intrusion in roof systems,
from Fluke. walls, flooring, ceilings and other
Optimized for harsh (outdoor) environments. building areas
Engineered and tested to withstand a 2 m (6.5 ft) drop Leaks in water pipes, buried steam
Withstands dust and watertested to an IP54 rating lines, water lines or underground
Fluke TiR1 Delivers the clear, crisp images needed to find problems fast. heating systems and sprinkler
Identify even small temperature differences that could systems
indicate problems with optimized thermal sensitivity Missing or inadequate insulation
(NETD) for building and roofing applications areas
High performance, low noise sensor provides high quality Heat or cooling loss, HVAC/R
image and stable temperature reading problem areas
Even the smallest details become visible with the large, Connection problems in low
widescreen full color LCD display voltage electrical systems
Intuitive, three-button menu is easy to use... simply navigate Termite and pest detection
with the push of a thumb. Construction defect management
No need to carry pen and paperrecord findings by speak- Fluke R Series thermal imaging
Fluke TiR ing into the cameracomments are saved with the image models are built specifically for the
(TiR1 only). building diagnostic industry. Property
Store more than 3,000 screen images (.bmp format) or 1,200 managers use thermal imaging to
IR-Fusion images on included 2 GB SD memory card. protect their investment and keep
buildings well maintained.

See page 41 to find out the power of


IR-Fusion Technologyonly available
from Fluke.

Find the thermal imager


Specifications TiR1 and TiR Imagers that fits your work
Go to
Features Fluke TiR1 Fluke TiR www.fluke.com/thermal_imaging
Temperature measurement -20 C to +100 C (-4 F to + 212 F)
range (not calibrated
below -10 C)
Accuracy 2 C or 2 % (whichever is greater) 5 C or 5 % (whichever is greater)
Measurement modes Smooth auto-scaling and manual scaling
Field of view 23 x 17
Spatial resolution (IFOV) 2.5 mRad
Minimum focus distance Thermal lens: 15 cm (6 in); Visible (visual) light lens: 46 cm (18 in)
Image frequency 9 Hz refresh rate
Detector type 160 X 120 focal plane array, uncooled microbolometer
Infrared lens type 20 mm F = 0.8 lens
Thermal sensitivity (NETD) 0.07 C at 30 C (70 mK) 0.1 C at 30 C (100 mK)
Visual camera 640 x 480 resolution
Palettes Ironbow, blue-red, high contrast, Ironbow, blue-red, high contrast, gray
amber, hot metal, gray
IR-Fusion information Full Infrared with Max, Mid, or Min Full Infrared or picture-in-picture
automatic blending; and picture-in-picture with
Max, Mid, or Min automatic blending
(Visual and IR blending) Use our online product selection tools,
Voice annotation 60 seconds maximum recording time per image return-on-investment calculator, and
Storage medium SD memory card 2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked how-to information to see how ther-
visual images each with 60 seconds voice annotations or 3000 basic (.bmp) IR images mal imaging would fit your work.
File formats Non-radiometric (.bmp) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp) files
Software SmartView full analysis and reporting software included
Power Battery: Internal rechargeable battery pack (included)
Battery life: 3 to 4 hours continuous use (assumes 50 % brightness of LCD)
Battery charge time using ac adapter/charger or dc car charger: 2 hours for full charge Included accessories
AC operation/charging AC adapter/charger (110 V ac to 220 V ac, 50 Hz to 60 Hz). Charges battery while Thermal imaging camera w/20 mm
imager is operating. Universal ac mains adapters included.
lens, ac power supply/battery char-
IP rating IP54
Warranty Two-years
ger (including mains adapters), SD
memory card, SD card reader (USB),
SmartView software, rugged hard
carrying case, soft transport bag,
Recommended accessories TiR1 and TiR Thermal Imagers
hand strap, users manual, warranty
registration card.

Ordering information
FLK-TIR1 9HZ Thermal Imager
Ti-CAR CHARGER FLK-TIR 9HZ Thermal Imager
Thermal Imager Car Charger

For more information, go to


44 Thermal Imaging www.fluke.com/thermal_imaging
TiR4FT, TiR3FT and TiR2FT IR
FlexCam Thermal Imagers
The experts choice for Sample applications
building diagnostics

The Fluke TiR2FT, TiR3FT and TiR4FT Thermal


Imagers are for professionals demanding the
best and most thorough solutions in building
diagnostics applications. The Fluke TiR-Series
provides the industrys largest LCD to view
on-camera images, augmented with the
innovative IR-Fusion technology to better Moisture detection: Accurately
pinpoint building problems. IR-Fusion is the detect moisture behind interior
overlay of IR and visible images, allowing one walls, in ceilings, and under
to clearly identify critical points within the carpets.
Fluke TiR2/FT, TiR3/FT, TiR4/FT thermal image.
Industry leading thermal sensitivity
( 0.050 C NETD on TiR4FT) ( 0.07 C
NETD on TiR2FT and TiR3FT) provides solid
resolution, and ultra high-quality images.
IR-Fusion technology automatically merges
See page 41 to find out the power of visual and thermal images, pinpointing
IR-Fusion Technologyonly available trouble areas quicker by automatically
from Fluke. relating thermal images with the real world.
The 180 articulating lens is great for Mold remediation: Control mold
viewing around obstructions. by revealing undetected sources of
The 5 inch high resolution, high contract display is the biggest display in the industry. moisture.
320 x 240 focal plane array and 20 mm high quality Germanium lens with continuous
single finger focus provide exceptional image resolution (Model TiR2FT available with
160 x 120 only).
SmartView professional report writing software generates fast, easy, customizable
reports including rich image analysis (see page 41 for more details).
The intuitive operation with on-camera Windows CE interface makes it easy to use.

Roofing: Detect water-saturated


insulation in flat-roof systems to
Specifications TiR4FT, TiR3FT and TiR2FT locate damaged portions of roofing
structure.
Features TiR4FT TiR3FT TiR2FT
Field of view (FOV)* 23 horizontal x 17 vertical
Spatial resolution (IFOV)* 1.30 mrad 2.60 mrad
Minimum focus distance* 0.15 m
Thermal sensitivity (NETD) 0.05 C at 30 C 0.07 C at 30 C
Detector data acquisition / 60 Hz 30 Hz
Image frequency
Calibrated temperature range -20 C to 100 C (-4 F to 212 F)
Accuracy 2 C or 2 % (whichever is greater)
Energy audits: Perform residential
Digital display 5 large high-resolution digital display
and commercial energy audits by
LCD backlight Sunlight readable color LCD scanning for heating or cooling
Video output RS170 EIA/NTSC or CCIR/PAL composite video (energy) loss, moisture invasion,
Palettes Grayscale, grayscale inverted, blue red, high contrast, hot metal, iron and HVAC/R problems.
Storage medium Compact flash card stores more than 1000 IR images (512 MB card standard)
File formats supported 14 bit measurement data included. Exportable BMP, GIF, JPEG, PNG, TIFF
Interface Compact flash card reader included
Included accessories
AC adapter (TiR2FT and TiR4FT
Software SmartView; full analysis and reporting software included
only), video cable, 512 MB compact
Warranty Two-years
flash card, compact flash card reader
*Standard 20 mm Germanium lens. and USB cable, PCMCIA compact
flash adapter, SmartView reporting
and analysis software on CD-ROM,
two rechargeable battery packs,
battery charger, neck strap, heavy
duty carrying case and user manual
Recommended accessories Ti4FT, Ti3FT and Ti2FT Imagers on CD-ROM.

Ordering information
FLK-TiR2/FT-20 IR FlexCam BD
Thermal Imager
FLK-TiR3/FT-20 IR FlexCam BD
103232 104543 Ti-SBC Ti-SBP
Anti-glare Hood Car Charger Battery Charger Rechargeable Battery Pack
Thermal Imager
FLK-TiR4/FT-20 IR FlexCam BD
Thermal Imager

For more information, go to www.fluke.com/thermal_imaging Thermal Imaging 45


Fluke 975 AirMeter
Five powerful tools in one, with Also available:
simple one-touch air velocity Fluke-975CK AirMeter Calibration
Kit includes the gases and tools
necessary to keep your Fluke 975
The Fluke 975 test tool combines five powerful air AirMeter calibrated.
quality tools into one. Identify and diagnose indoor
air quality issues quickly and easily with one rugged,
handheld device. The Fluke 975 measures and simul-
taneously displays temperature, humidity, CO2 and CO.
At the press of a button, it quickly measures air flow
and percentage of outside air.
Simultaneously measures, logs, and displays
temperature, humidity, CO2, and CO on a bright,
backlit LCD display.
% of outside air calculation.
One-touch air flow and velocity with available probe.*
Dew point and wet bulb temperature.
CO2 and CO field calibration feature.
Min/Max/Average on all measured and calculated
readings.
Audible and visual threshold alarms.
Extensive discrete or continuous data logging
capacity, downloadable to PC via USB interface. Fluke-975VP AirMeter
Includes NIST-traceable certificate of calibration. Velocity Probe for use
Automatically compensates for barometric pressure with Fluke 975 AirMeter.
changes.
Two-year warranty.
*Included with Fluke 975V, optional with Fluke 975.

Features Range Display Resolution Accuracy


Temperature -20 C to 50 C 0.1 C (0.1 F) 0.9 C/ 1.62F from 40 C to 60 C 0.5 C/
(-5 F to 122 F) 1.00F from 5 C to 40 C 1.1 C/ 1.98 F from
-20 C to 5 C
Relative humidity 10 % to 90 % RH 1% 2 % RH (10 % RH to 90 % RH)
non-condensing
Air velocity 50.0 fpm to 3000 fpm 1 fpm (0.005m/sec) 4 % or 4 fpm* 4 % or 0.02 m/sec* whichever is
0.25 m/sec to 15 m/sec greater *Accuracy specification only valid for velocity
readings above 50 fpm. See page 25 for information on the
CO2 0 to 5000 ppm 1 ppm Warm up time 1 min (5 minutes for full specification)
2.75 % + 75 ppm
902 True-rms HVAC Clamp Meter.
CO 0 to 500 ppm 1 ppm 5 % or 3 ppm, whichever is greater, @ 20 C
and 50 % RH

Fluke 922 Airflow Meter/Micromanometer Included accessories


Analyze airflow. Easily. Fluke 975: AA alkaline batteries (3),
users manual (with safety informa-
tion), calibration cap, hard carrying
Make airflow measurements easy by combining differential case, FlukeView Forms software,
pressure, air flow, and velocity into a single, rugged meter. power adapter, international power
Used with any pitot tube, the Fluke 922 is the perfect entry plugs, air velocity probe (Fluke 975V
point for technicians measuring air flow for the first time, yet only).
powerful enough for advanced users.
Measures differential and static pressure, air velocity and Fluke 922: Two rubber hoses, four
flow readings AA alkaline batteries 1.5 V, users
User-defined duct shape and size for maximum airflow accuracy manual, soft carrying case.
Bright, backlit display Fluke 922 Kit: 12 inch pitot tube,
Min/Max/Average/Hold functions two rubber hoses, ToolPak Magnetic
Auto power off Meter Hanging Kit, four AA alkaline
batteries 1.5 V, users manual, hard
Features Range Accuracy carrying case.
Air Pressure 4000 Pascals 1 % + 1 Pascal
16 in H2O
400 mm H2O
1 % + 0.01 in H2O
1 % + 0.1 mm H2O
Ordering information
40 mbar 1 % + 0.01 mbar FLUKE-975 AirMeter
0.6 PSI 1 % + 0.0001 PSI
FLUKE-975V AirMeter with
Air Velocity 250 to16,000 fpm 2.5 % of reading at 2000 fpm
(1 to 80 m/s) (10.00 m/s) Velocity
Air Flow (Volume) 0 to 99,999 cfm Accuracy is a function of velocity and FLUKE-922 Airflow Meter
0 to 99,999 m3/hr duct size FLUKE-922/Kit Airflow Meter Kit
0 to 99,999 l/s
Temperature 0 C to 50 C (32 F to 122 F) 0.1 C (0.1 F)
Data Storage 99 readings
Warranty Two-years
Power Four AA batteries

46 Indoor Air Quality For more information, go to www.fluke.com/IAQ


Indoor Air Quality Tools
Easy-to-use tools to help you CO-220 Carbon
maintain good IAQ Monoxide Meter
Stand-alone CO meter that
does not require a digital
Fluke 971 Temperature Humidity Meter multimeter.
Temperature and humidity are two important factors in Large backlit LCD displays
maintaining optimal comfort levels and good indoor air quality. CO levels from 0 to 1000 ppm.
Quickly and conveniently take accurate humidity and temperature Beeper triggers with
readings with the Fluke 971. The Fluke 971 is invaluable for increasing frequency as CO
facility maintenance and utility technicians, HVAC-service levels rise.
contractors, and specialists who assess indoor air quality (IAQ). MAX hold function stores
Lightweight and easy to hold, the Fluke 971 is the perfect tool for and displays the maximum
monitoring problem areas. With a rugged holster and twist-open CO level.
protective sensor cover, the Fluke 971 is built to perform and Automatic sensor zeroing and
made to last. self-test upon startup.

Features:
Backlit dual display of humidity and temperature.
Measures dew point and wet bulb temperatures.
99 record storage capacity.
Ergonomic design with belt clip and protective holster.
Quick-response capacitance sensor with twist-open
protective cover.
Compact and lightweight at 188 g (6.6 oz). CO-205
Temperature range from -20 C to 60 C (-4 F to 140 F). Aspirator Kit
Relative humidity from 5 % to 95 %. The CO-205 flue gas sampling
Min/Max/Avg Data hold. accessory kit includes:
Low battery indicator. Stainless steel sampling tube.
One-year warranty. Aspirator to draw flue sample.
Replaceable particulate filter.
Nose cap for connection to the
Fluke CO-210/CO-220.
Fluke 983 Particle Counter
The Fluke 983 Particle Counter measures and displays six
channels of particle size distribution. The Fluke 983
holds 5000 logged samples including date, time,
counts, sample volume, temperature and relative
humidity. Data is easily downloaded using the
included windows compatible utility software.
The Fluke 983 is invaluable for IAQ investigations,
allowing you to determine size distribution of
airborne particles or track down a particle source.

Features:
Compact and easy to operate.
Graphic liquid crystal display with backlight.
Simple connection to computer or printer.
Selectable sample time, count data and
programmable delay.
Set sample size to cubic feet or liters, set Included accessories
temperature measurements to C or F. Fluke 971: Users manual, four AAA
alkaline batteries.
Data displayed in totalize or concentration modes.
Automatic turn-off when battery voltage drops Fluke 983: Certificate of Calibration
below safe operating level. (NIST), Windows compatible software
Meets JISB9921:1997 and CE standards. download utility, DB9 to RS-232
Battery or ac operation with internal rechargeable adapter and cable, isokinetic probe,
battery. high purity tubing, 1/8 inch hose barb
adapter, power supply, users manual,
Protective holster.
zero count filter, protective holster and
Rugged, hard shell carrying case. hard molded plastic case.
One-year warranty.
Ordering information
Fluke RLD1 Leak Detector FLUKE-971 Temperature
The compact, easy-to-use, RLD1 UV flashlight uncovers Humidity Meter
refrigerant leaks instantly. The green LED indicates when FLUKE-983 Particle Counter
the leak detector is on, by highlighting the leak detection FLUKE-983TPK 220 Thermal Printer
dye. With 100,000 hours of life, this handy leak detector is Kit, 220 V
a must have for HVAC Technicians. FLUKE-983TPK 120 Thermal Printer
UV LED (375 nm wavelength) detects leak detection dyes. Kit, 120 V
Easy to use with press and hold power control. FLUKE-CO-205 Aspirator Kit
FLUKE-CO-220 Carbon
Green LED indicates UV light on. Monoxide Meter
Operating temperature 0 C to 50 C.
Convenient key chain and AAA battery included.

For more information, go to www.fluke.com/IAQ Indoor Air Quality 47


Fluke ScopeMeter

Test Tools
Handheld oscilloscopes for professionals
with challenging troubleshooting situations

The ScopeMeter 192, 196 and 199 high-performance oscillo-


scopes have bandwidth of 60, 100 and 200 MHz and sample
rates up to 2.5 GS/s. The C models add a high-resolution color
display that has a fast update rate, waveform pass/fail testing
and a digital persistence modemaking the analysis of com-
plex and dynamic signals that much easier.
For industrial, electronic or electro mechanical applications,
the 123, 124 and 125 Industrial ScopeMeters feature 20 MHz
or 40 MHz bandwidth, Connect-and-View software for quick
measurements and a dual DMM and paperless recorder to get
virtually any job done.

Specifications ScopeMeter Test Tools


Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123
Bandwidth 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 20 MHz
Max real time sample rate 2.5 GS/s 1.0 GS/s 2.5 GS/s 1.0 GS/s 0.5 GS/s 25 MS/s 25 MS/s
Max record length (per input) 3000 points 512 points (min/max pairs)
Number of Inputs 2 Scope and 1 DMM (Isolated) 2 Scope Or DMM
Input sensitivity 2 mV/div to 100 V/div 5 mV/div to 100 V/div 5 mV/div to 500 V/div
Independently isolated floating inputs
Display and display modes
Display Color Monochrome Monochrome
Persistence Digital with variable decay On/Off
Envelope mode
Waveform compare
FFT
Pass/fail testing
Triggering
Connect-and-View trigger
Edge, single, free run
Video
Video lines
Pulse width
External With ITP 120 Option
Advanced functions
Cursors Cursors and
power
measurements
Zoom
Dual input Trendplot
ScopeRecord mode
Automatic capture and replay last 100
screens
Waveform mathematics Harmonics
mode
Save setups and screens 10 20 10
True-rms multimeter 5000 counts, volts, amps, ohms, continuity, diode, temp
Safety, power and warranty
Safety (EN61010-1) CAT II 1000 V/CAT III 600 V CAT III 600 V1
Battery 4-hour Ni-MH 7-hour NiMH 7-hour NiMH
Line power Adapter/battery charger included
PC printer interface Yes, using optional optically isolated cable
Warranty Three-year on main instrument/one-year on standard accessories
1Max input voltage CAT II 1000 V with VPS40, 40 MHz 10:1 voltage probe.

Recommended accessories ScopeMeter Test Tools

Model Description 192, 196, 199 123, 124, 125


SCC 120 Software, cable and carrying case package
SCC 190 Software, cable and carrying case package
C125 Compact soft case TM
C195 Universal soft carrying case
PAC91 Optical to parallel printer adapter cable

48 ScopeMeter Test Tools For more information, go to www.fluke.com/scopemeter


Fluke 120 Series
ScopeMeter Test Tools

Three-in-one simplicity for Verifying CAN bus signals


fast answers wherever you work with a Fluke ScopeMeter
120 Series
Verifying the
The compact ScopeMeter 120 Series is
physical layer
the rugged solution for industrial trouble-
signals of two-
shooting and installation applications.
wire differential
Its a truly integrated test tool, with
serial bus
oscilloscope, multimeter and paperless
system.
recorder in one affordable, easy-to-use
instrument. Find fast answers to problems Download this
in machinery, instrumentation, control application
and power systems. note at
www.fluke.
com/CAN-bus.

Power
and har-
monics
The 125
measure-
ments are
Dual-input 40 MHz or 20 MHz digital Use TrendPlot to help find extended
oscilloscope. intermittents, fast to include
Two 5,000-count true-rms digital The toughest power
multimeters. faults to find are measure-
A dual-input TrendPlot recorder. those that hap- ments VA,
Connect-and-View trigger simplicity for pen only once VAR, W and PF (power factor) plus
hands-off operation. in a while Harmonics. Power is measured on
Shielded test leads for oscilloscope, intermittents. single-phase or balanced three-phase,
resistance and continuity measurements. They can be three-wire systems (in delta set-up).
New! Industrial Networks bus health caused by bad To troubleshoot motor windings the
testing (Fluke 125). connections, 125 resistance has been increased to
New! Measure harmonics and power, dust, dirt, cor- include a 50 ohm range with a reso-
VA, VAR, W, PF (Fluke 125). rosion or simply lution of 0.01 ohms.
Up to seven hours battery operation. broken wiring or connectors. Other factors,
600 V CAT III safety certified. like line outages and sags, can also cause a Battery powered mobility
Optically isolated RS-232 interface. machine to stop. You may not be around to Up to seven hours of battery operation
Rugged compact case. see ityour Fluke ScopeMeter will. In this frees you from mains outlets for true
paperless recorder mode, you can plot the on-the-move working. The rugged
A three-in-one tool minimum and maximum peak values and and drip proof case assures long life
ScopeMeter 120 Series combines a 40 MHz average over timeup to 16 days. and reliable operation in the harshest
or 20 MHz dual input digital storage oscil- industrial environments.
loscope, two true-rms digital multimeters Industrial network bus health
and a dual input TrendPlot recorder all in Digital data Safety certified
a compact, battery powered instrument. networks now The ScopeMeter 123 is safety certified
connect plant for measurements on CAT III 600 V
Connect-and-View triggering equipment,
for an instant, stable display posing new
Scope users troubleshoot- Ordering information
ing challenges. FLUKE-125S Industrial ScopeMeter,
know how dif-
Bus Health, Power &
ficult triggering Checking the
Harmonics with SCC120
can be. Incorrect electrical integ- kit
settings show rity of the digi- FLUKE-125 Industrial ScopeMeter,
unstable and tal signal can Bus Health, Power &
sometimes isolate defective Harmonics
incorrect results. equipment or FLUKE-124S Industrial ScopeMeter,
Flukes unique uncover eminent shutdowns of a segment 40 MHz, with SCC120 kit
Connect-and- that appears to be operational. The 125 FLUKE-124 Industrial ScopeMeter,
View recognizes bus health test will verify key parameters 40 MHz
signal patterns and automatically and of the digital signal against industry stan- FLUKE-123S Industrial ScopeMeter,
continuously sets up correct triggering. It dards giving a clear indicator of bus state 20 MHz, with SCC120 kit
provides a stable, reliable and repeatable good or bad. FLUKE-123 Industrial ScopeMeter,
display of virtually any signal. 20 MHz
SCC120 Kit containing FlukeView
software for Windows,
USB interface adapter/
cable and hard case

For more information, go to www.fluke.com/scopemeter ScopeMeter Test Tools 49


Fluke 192, 196 and 199
ScopeMeter Test Tools

Speed, performance and analysis power. All DSO isolated channels


See more, fix more with color. are not the same
Displaying information from multiple
information
Whether you are performing routine maintenance and sources
calibration, or troubleshooting the hardest to solve problems channels at
All DSO isolated
channels are not
like intermittent failures or sources of unwanted noisethe once is critical to
the same Application Note

Fluke ScopeMeter 192, 196 and 199 include all the tools
The ability to display informa- able for use only to about 30 V,
tion from multiple information which is severely inadequate

troubleshooting
sources channels at once for industrial environments. By
is critical to troubleshooting and contrast, the isolation on the
maintaining todays complex Fluke ScopeMeter 190 Series
equipment. Virtually all modern is certified up to a 1000 V CAT

needed to get the job done. With 200 MHz bandwidth, up


power control systems have II safety rating and 600 V CAT

and maintaining
circuitry designs that require III. That level of isolation makes
different reference measure- the 190 an extremely safe
ments. Control circuits based on instrument for professional and
micro-controllers, for example, industrial applications.

to 2.5 GSa/s real-time sampling rate, 27500 points memory


are likely to run at the 3 or 5 V Those differences are critical,
levels of todays logic systems, for both accuracy and safety.

todays complex
whereas the power electronics The need to measure and
could well be driven by the 380 capture waveforms from differ-
V three-phase mains supply. To ent test points in sources is
complicate matters even more, such a common requirement

for high resolution waveform ScopeRecord, measurement


such systems may be designed that it is easy to forget that
with one or more floating incorrectly attaching a dual-

equipment and
sections so even their grounds input oscilloscope without
are not the same adequately isolated channels
voltage. can be a safety hazard. Its not
In the past, technicians and uncommon for oscilloscopes

TrendPlot and FFT analysis, analyzing signal details,


engineers have juggled the without industrial-strength
need to track such divergent isolated channels to encounter

most modern
system components by using unexpected or unknown diver- drives to switched-mode power
multiple test instruments at gent grounds, which can cause supplies and all manner of
once. A more accurate and the instrument to short out or high-energy industrial systems.
efficient method is to employ in extreme cases explode. Even Fluke relied on the advice of

finding random glitches and sources of unwanted noise or


a handheld Fluke Corporation if users encounter no system its most valuable design team,

power control
ScopeMeter 190 Series. Unlike unknowns, the drive for speed its customers, as it developed
standard dual-input oscillo- and efficiency can encourage the extended isolated channel
scopes in which the inputs are unsafe work habits. Too often, capacity, said Hilton Hammond,
connected to a common ground, bench-top oscilloscopes are Flukes ScopeMeter U.S. product

interference become routine tasks.


ScopeMeter 190s three inputs operated ungrounded to make manager.
are independently isolated, their inputs floating, greatly Our customers were asking

systems circuitry
which means they can be increasing the danger of physi- for it, he said. They need to
connected to signals of widely cal injury or even electrocution. be able to safely and accurately
differing voltage reference The level of channel isolation look at two different signals

Dual-input200 MHz, 100 MHz or 60 MHz bandwidth.


levels with complete accuracy engineered into the ScopeMe- with two different ground
and safety. And the standard ter 190 protects the unit, the potentials. The 190, with its
probes cover a wide application equipment youre troubleshoot- isolated channel architecture,

require different
range from mV to kV, making ing, your test tool investment, IEC safety rating of 1000 V
the ScopeMeter 190C ideal for and your eyebrows. CAT II and 600 V CAT III, does
micro electronics to electrical The heavy-duty strength of exactly that!

Up to 2.5 GS/s real-time sampling and 3 k points


power applications. the 190 Series isolated chan-
Beware. A few other dual- nel capabilities are allowing
input oscilloscopes say they technicians to easily, accurately

reference mea-
have isolated channels, but and safely troubleshoot and
the isolation is limited, suit- maintain systems from ac motor

memory per input. surements. Now


Automatic and advanced triggering functions
From the Fluke Digital Library @ www.fluke.com/library

one tool will do


Connect&View, pulse width, dual slope and n-cycle for it all.
synchronizing on specific waveform details.
Fast Fourier Transform (FFT) for frequency domain, spectrum display of signal harmonics or Download this application note at
fidelity (C models). www.fluke.com/DSO-channels.
Digital persistence for analyzing complex dynamic waveforms such as on an analog
scope (C models).
Automatic capture and replay of 100 screens.
27,500 points per input record length using ScopeRecord mode.
TrendPlot paperless chart recorder for trend analysis up to 22 days.
Waveform reference for visual comparisons and automatic pass/fail
testing (C models) of waveforms.
Four hours rechargeable Ni-MH battery pack.

See whats really happening Automatic capture and


With a maximum real-time sampling rate of replay of 100 screens
2.5 GS/s per input, you can see what really Scope users know how frustrating it is to
happens, with 400 ps resolution. Both inputs see a one-time anomaly flash bynever to
have their own digitizer, so you can simulta- be seen again. Not with the ScopeMeter 190
neously acquire two waveforms and analyze Series. Now you can look back in time with
them with the highest resolution and detail. a touch of the replay button. In normal use, Waveform Pass/Fail testing
If an anomaly flashes by on the screen, just the instrument continuously memorizes the Waveform reference allows an acquired
press the Replay button to see it again. last 100 screens. Each time a new screen is trace to be stored and designated as a
acquired, the reference trace for visual comparisons,
Frequency Spectrum Analysis oldest is discard- or it can be used as the reference for
All C models now include Frequency ed. At any automatic Pass/Fail testing (C models
Spectrum Analysis functionality based on moment only). Up to 100 individually matching
FFT analysis as a standard feature. This you can (Pass) or non-matching (Fail) waveforms
makes it possible for you to identify the indi- freeze the can be stored in the replay memory
vidual frequency components contained in last 100 (C models only), allowing you to moni-
a signal. The spectrum analysis function is screens tor your systems behavior over a long
also handy to reveal the effects of vibration, and scroll period of time, without the need for you
signal interference or crosstalk. An automatic through to attend!
window function assures optimal window- picture-by-picture or replay as a live anima-
ing, although you may manually select your tion. Cursors can be used for further analysis.
preferred time window.
Deep memory for high- Ordering information
resolution ScopeRecord FLUKE-192B/003 ScopeMeter 60 MHz
B/W
and Trendplot FLUKE-192B/003S ScopeMeter 60 MHz
The ScopeRecord memory stores 27,500 B/W with SCC kit
points per input, for high-resolution record- FLUKE-196B/003 ScopeMeter 100 MHz
ing of waveform events up to 48 hours, and B/W
captures fast intermittents and glitches as FLUKE-196B/003S ScopeMeter 100 MHz
short as 50 ns. This continuous roll mode B/W with SCC kit
also stores events like motion profiles, UPS, FLUKE-199B/003 ScopeMeter
power supply and motor start-ups. 200 MHz B/W
In Trendplot or paperless recorder mode, FLUKE-199B/003S ScopeMeter 200 MHz
you can plot the minimum, maximum peak B/W with SCC kit
and average measurement (DMM or auto- FLUKE-196C/003 ScopeMeter 100 MHz
matic scope) values over timeup to 22 days. color
The two inputs can plot any combination FLUKE-196C/003S ScopeMeter 100 MHz
of volts, amps, temperature, frequency and color with SCC kit
phase with time and date stamp to help lead FLUKE-199C/003 ScopeMeter 200 MHz
color
you to the cause of those faults quickly.
FLUKE-199C/003S ScopeMeter 200 MHz
color with SCC kit

For more information, go to


50 ScopeMeter Test Tools www.fluke.com/scopemeter
Fluke ScopeMeter

Test Tool accessories


ScopeMeter accessories
Measurements made easier Fluke acces-
sories can
enhance or
expand the
Cable and adapters measurement
capabilities
PAC91 PM9091 of your
Printer adapter cable 0.25 m 50 ohm coaxial BNC cable set, ScopeMeter.
Safety designed optical to 3 m x 1.5 m Go to www.
parallel printer adapter cable Three colored BNC male fluke.com/
See instrument manual for connectors (red, gray and scopemeter
compatible printers black) for easy identification for your copy
of the
ScopeMeter
accessories
data sheet.
OC4USB PM9092
Optically-isolated 50 ohm coaxial BNC cable set,
serial to USB 3 m x 0.5 m
adapter Three colored BNC male
connectors (red, gray and
black) for easy identification

PM9081 PM9093
Dual banana plug Male BNC to
4 mm male to dual female
female BNC adapter BNC T-piece
The set consists of two Set consists of
adapters two adapters

PM9082 BB120
Dual banana jack Two shielded banana-
4 mm female to to-BNC adapters
male BNC adapter Adapting probes and BNC
The set consists of adapters to 123 and 124
two adapters ScopeMeter test tools

Trigger and differential probes


DP120 Differential Probe ITP120 Optically Isolated Trigger Probes
1.5 m with shrouded banana probe tips 1.2 m, for ScopeMeter 123
(red and black) Included hookclip with ground lead
CAT III 600 V/CAT II 1000 V rated Max. signal voltage and voltage to ground:
CAT II 600 V rms

Software, carrying cases and kits


SCC120 Software Cable Case for C195 Soft Carrying Case Universal
123, 124, 125 Durable soft case. Adjustable storage
SCC190 Software Cable Case for compartments suitable for all
ScopeMeter models. Storage
192, 196, 199 compartments for test leads, probes,
Accessories package, including: instruction manual, power adapter
FlukeView ScopeMeter Software for and other accessories
Windows English, French and
German languages C125 Compact Soft Case for
OC4USB Optically Isolated RS-232
Adapter/Cable 123, 124, 125
Hard carrying case C120 or C190 Zippered carrying case (black) for
123, 124
C120 Hard Carrying Case for Pouch is designed to carry test leads
and probes
123, 124, 125 Convenient belt loop accommodates
C190 Hard Carrying Case for tool belt
192, 196, 199
Storage compartments for test leads, probes,
instruction manual, power adapter and other small accessories

For more information, go to www.fluke.com/scopemeter ScopeMeter Test Tools 51


Fluke accessory
selection guide
Find the right accessories to
make your meter work for you

80 Series III/83V
114/115/116/117

51/52/53/54 II
8845A/8846A
20/70 Series
10/11/12/12B

110/111/112

330 Series
190 Series
120 Series

63/66/68
90 Series

50S/50D
70/73 III

87/89 IV

566/568
287/289

725/726
705/707

787/789
321/322

741/743
187/189
175/177

712/713

716/717
39/41B

8808A
T3/T5

1587

1577
87V

43B

744

561
179

714

715

718
27

i200 73 3
i200s
i400 73 3
i400s 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
80i-600A 73
Current

i1000s 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
i2000 flex
i3000s flex
i3000s 3 3
i410 5 5 5 5 3 3
i1010 5 5 5 5 3 3
i30/i30s
80AK-A 116
80BK-A 116
All 80PK Probes 1 1 D 1* 1 1 2 1 2 2 2 2 1 1 1 1 1 1 1 2 2
80PJ-1/80PJ-9
80PT-25
Temperature

80TK
80T-150U
80PJ-EXT
80PK-EXT 1 1 2 1 1 1 1 2 1 2 2 2 2 1 1 1 1 1 1 1 2 2
80PT-EXT
80CK-M 1 1 2 1 1 1 1 2 1 2 2 2 2 1 1 1 1 1 1 1 2 2
80CJM
80PR-60 66/
68
C50
C520
C550/C1600 The C550 and C1600 are large enough to hold accessories and multiple test tools (see page 70)
C12A
C23
C25
Cases

C33
C43
C90
C125
C789
C20 789
C101
C510
C10 * *
C70Y
H80M 787
Holsters

H3
H5
H6
TPak 83V 789
C570
Standard Test
Lead Input
TLK287
TLK289
TL220
Test Leads

TL223
TL225
TL238
TL80A
TL81A
TL71
TL76
FlukeView Forms ** 789
Software
Specialty

PV350 (pressure)
FOM (fiber optic)
CO-210
80K-6, 80K-15, dc dc dc dc
80K-40 only only only only
(1) Requires 80TK (2) Requires 80AK-A. (3) Limited low level ac capability see page 39. (4) Requires PM9081/001 Adapter. (5) Requires PM9082/001 adapter 115, 117 only D116 only requires 80AK-A.
A universal accessory. Works with most brands of meters. For detailed Current Clamp specifications see pages 58 and 59. *Included with the 12B and 16 **53, 54 only.

52 Accessories For more information, go to www.fluke.com/accessories


Fluke accessory
sets and kits
Combines our most popular accessories
into convenient money saving packages

TL238 SureGrip Test


New! TLK289 Industrial Lead Set for high energy
Master Test Lead Set environments
Designed for electrical and electronics Insulated tip probes help lessen
risk of arc flash explosion
test in todays industrial environment TLK-220 SureGrip Accessory
Includes: Kit with Meter Carry Case
Probe extenders keep hands
away from live current
SureGrip alligator clips, grabbers, AC220 plunger style alligator clips
hook clips and industrial test probes Includes one pair each, insulated
for dependable contact with a variety
AC285 large jaw alligator clips test tip probes, probe extenders
of test points
TP220 sharp test probes and TL224 Test Leads
Magnetic hanger for convenient
TL224 right to straight test leads Probes and leads CAT III 1000 V,
suspension of your DMM from a
Zippered vinyl carry case with moveable CAT IV 600 V, 10 A, extenders
divider CAT III 1000 V 10 A
metal surface
Temperature adapter with K-Type
Holds large DMMs
thermocouple for direct temperature
measurement with your DMMs
temperature measurement functions TLK-225 SureGrip
Protective soft case for your DMM and Master Accessory Kit
all its accessories AC220 plunger style
alligator clips
AC280
plunger style
hook clips
AC283 plunger
style pincer
clips
AC285 large
jaw alligator
clips
TP220 sharp TL220 Industrial
test probes Test Lead Set
TL224 right to
Starter kit for industrial applications
straight test leads
6-pocket storage TP220 has round, stainless steel tip
pouch, keeps the Includes 1 pair: AC220, TP220,
TL222
entire set together
CAT III 1000 V, CAT IV 600 V, 10 A

New! TLK287 Electronics T5 Tester Starter Kit


Master Test Lead Set Getting started kit for
electricians who already
The perfect test lead kit for todays own a Fluke T5 Tester.
electronics test and design
Includes: TP220 test probes
Precision electronic probes with AC285 large jaw
multiple spring-loaded sharp tips to alligator clips
maximize contact with SMD test C33 zippered soft
points case
Micro-grabbers and leads to enable
fine SMD test
Mini-alligator clips, grabbers, and
probes for virtually every electronics TL223 Electrical
need Test Lead Set
Both modular test leads and Starter kit for electrical applications
lead-probe combinations. Even TP1 has flat blades for wall sockets
couplers for long lead applications Includes 1 pair: AC220, TP1, TL224
CAT III 1000 V, CAT IV 600 V, 10 A

For more information, go to www.fluke.com/accessories Accessories 53


Fluke SureGrip
accessories
A complete set of Superior gripping

probes, leads and clips surface made from


thermoplastic rubber

Modular test leads and test probes (use test probes with test leads)

TL221 SureGrip TP1, TP2, TP4 and


Silicone Test Lead TP38 Slim Reach
Extension Kit Test Probes
Superior strain relief Slender probe bodies for
Includes two adapters to probing closely spaced or
extend leads 1.5 m recessed points
CAT III 1000 V, 10 A, TP1 has a flat blade
CAT IV 600 V, 10 A TP2 has 2 mm diameter tip
TP4 has 4 mm diameter tip
TL222 SureGrip TP38 has stainless steel
Silicone Insulated insulated probe to help New design makes
Test Leads lessen the risk of arc flash clips, hooks and

Recommended for use


explosion
CAT III 1000 V, 10 A,
probes more versatile
with AC220, AC280,
AC283 test clips CAT IV 600 V, 10 A SureGrip accessories provide a
Superior strain relief reliable grip in slippery hands.
CAT III 1000 V, 10 A, TP220 SureGrip
Industrial Test Probes
Rubber-overmolded surfaces and
CAT IV 600 V, 10 A finger-hugging curves give the
Sharp, 1/2 in. stainless user a comfortable, steady hold on
TL224 SureGrip steel tip provides reliable
contact the accessory so they can focus on
Silicone Insulated making an accurate measurement.
Test Leads Flexible finger barrier
improves grip
1.5 m silicone-insulated CAT III 1000 V, 10 A,
wire resists heat
CAT IV 600 V, 10 A
and cold
Superior strain relief
CAT III 1000 V, 10 A,
Push-on clips Test lead and probe in one
CAT IV 600 V, 10 A

AC72 Alligator Clips TL71 Premium


TL27 Heavy Duty
Test Leads Slide-on style for test DMM Test Lead Set
Rugged EPDM insulation probes Flexible silicone
1.5 m long with shrouded, Jaws open to 8 mm insulated leads are
straight connectors and For use with TL71 and heat and cold resistant
excellent strain reliefs TL75 test lead and probe Distinctive comfort
sets grip probes
on each end
CAT III 1000 V, 10 A, CAT III 1000 V, 10 A, Recommended for V
CAT IV 600 V, 10 A measurements
CAT IV 600 V, 10 A
CAT III 1000 V, 10 A,
CAT IV 600 V, 10 A

TL28A Heavy Duty


Test Lead Set
Modular clips (for use with test leads) Large, solid copper
alligator clips with
AC220 SureGrip AC285 SureGrip 0.5 in. opening
Alligator Clips Alligator Clips Flexible silicone
Insulated, nickel plated Multi-purpose tooth pattern insulated lead are
heat and cold resistant
jaws grip objects up to grips anything from fine
3/8 in. gauge wire to a 3/4 in. nut CAT I 30 V, 10 A
Blunt tip grabs round screw Nickel-plated steel jaws
heads CAT III 1000 V, TL76 2 mm/4 mm
CAT III 1000 V, CAT IV 600 V, 10 A Test Lead Set
CAT IV 600 V, 10 A 2 mm threaded probes
AC89 Heavy Duty with removable 4 mm
AC280 SureGrip Insulation Piercing Clip banana-style spring
Hook Clips Plunger style, safety grip
contacts
Profile narrows to .22 in. operation with insulated Flexible 1.5 m
silicone leads
at tip jaws
Hook opening .20 in. at Small pin pierces 30 to CAT III 1000 V,
front, .08 in. at base 14 AWG insulated wire CAT IV 600 V, 10 A
CAT III 1000 V, CAT III 1000 V, 5 A,
TL75 Hard Point
CAT IV 600 V, 3 A CAT IV 600 V, 5 A
Test Lead Set
AC283 SureGrip AC87 Heavy Duty Extremely hard alloy
Pincer Clips Bus Bar Clip Set tips resist wear
4.5 in. flexible, insulated One pair (red, black) of flat, Distinctive comfort
shaft right angle design for grip probes
Nickel plated pincers open connecting to bus bars CAT III 1000 V, 10 A,
to .20 in. Adjustable collar provides CAT IV 600 V, 10 A
1.5 m PVC leads
CAT III 1000 V, two ranges of jaw openings
CAT IV 600 V, 1 A up to 30 mm
CAT III 1000 V, 5 A rating

54 Accessories For more information, go to www.fluke.com/accessories


Fluke test leads,
probes and clips
Test leads for all your
measurement needs

For electronic applications

TL910 Electronic TP80 Electronic


Test Probes with Test Probes
Replacement Tips Tapered tip ideal for
Small profile provides probing electronic
components or
accessibility
Comes with 5 sets of boards
replaceable tips Removable guard for
Replacement tips: TP912 IC probing
CAT III 1000 V, 3 A CAT III 1000 V, 10 A

TP920 Test Probe


Adapter Kit
TL80A Basic Electronic Test Lead Set IC test tip adapters,
6 piece set with zippered case extended tips,
Probes, alligator clips and tip extenders for medium alligator
clips fit over
electronic applications
CAT II 300 V TL71 and TL75
test lead sets
IC test tip
Adapter, 3 A
For automotive applications Extended probe tip,
TP40 Automotive 3A
Back Probe Pin Set Med. alligator
clip, 5 A
Set of five 1.5 inch pins Rated to CAT II 300 V
60 V dc
Provide an easy connection past
weather pack seals to connector conductors TL40 Retractable
TP81, TP82 and TP84 Use with Fluke TL71 or TL75 test lead sets Probe Assembly
New piercing probes for automotive Retractable,
applications. Control the depth as you insulated sharp
pierce insulation. probe tip
Stainless steel probe pierces insulation CAT III 300 V, 3 A
on 14, 16 and 18 gauge wire
Design provides complete insulation while
TL26A Telecom
working on fuel injectors or sensors
TP81 for use with modular test leads (Fluke Test Lead Set
TL224) 5-way multipoint
TP82 slips over probe tips (Fluke TL71) test clips for
TP84 is 12 inches long to reach farther into telecommunications
applications
engine compartments.
Rated to 60 V dc TL82 Automotive Pin & Socket Adapter Set

Collection of male and female adapters allows you to
Flexible silicone
insulated leads are
TP88 Rigid make firm connection to pin and socket connectors heat and cold
Backprobe Pin Set
Adapters with flexible tips come in the following resistant
2 inch long pins pass
sizes: 22, 20, 16 and 12

Rated to 60 V dc
CAT I 30 V, 8 A
between the weather pack
seal and wire
Use with Fluke TL71 or TL75 test lead sets
Rated to 60 V dc
High-voltage probes

80K-6, 80K-15, 80K-40


High Voltage Probes
Allows a digital multimeter
to measure up to
6,000 volts peak,
15,000 volts peak
and 40,000 volts peak
TLK282 Deluxe Automotive Test Lead Kit respectively
TP81 Insulation Piercing Probes 1000:1 division ratio output
when connected to
TLK281 Automotive Test Lead Kit Set of five TP40 Automotive Back Probe Pins 10 MW multimeter
TP81 Insulation Piercing Probes TL224 Suregrip Silicone Test Leads Ground clip
TL224 Suregrip Silicone Test Leads TP220 Suregrip Test Probes included
TP220 Suregrip Test Probes AC220 Suregrip Plunger Style Alligator Clips Intended for low
AC220 Suregrip Plunger Style Alligator Clips AC285 Suregrip Alligator Clips energy applica-
AC285 Suregrip Alligator Clips C280 Suregrip Hook Clips tions that are
Handy Fluke carrying case Handy Fluke carrying case referenced to ground
TP81 rated to 60 V dc; all others rated to TP81 and TP40 rated to 60 V dc; all others rated to 80K-15 (not available
CAT III 1000 V, CAT IV 600 V CAT III 1000 V, CAT IV 600 V
in Europe)

For more information, go to www.fluke.com/accessories Accessories 55


Fluke illuminates
the task at hand
Get all the light you need and
keep your hands free

LVD1 Volt Light Shed light on the point of contact


Exclusive dual-sensitivity
Detects voltages from 40 V ac to 300 V ac
Voltage detector glows blue at 50 Hz to
60 Hz or 2.5 cm to 38 cm (1 in to 5 in)
away from source
Ultra-bright white LED with 100,000 hour
bulb life
AAA battery included

L211 Probe Light Kit


L200 probe light
TL71 premium DMM test lead set
C75 zippered case

New! LVD2 Volt Light


Non-contact ac voltage detector and
bright white LED flashlight
Detects voltage from 90 V to 600 V ac
from 1 to 5 inches away
CAT IV rated, one-year warranty

L200 Probe Light


Small, rugged light easily attaches to
any Fluke test probe
Bright white LED never burns out
120-hours of battery life
Two 3 V watch batteries included L215 SureGrip Kit with Probe
Light and Probe Extenders
L200 probe light
L205 Mini Hat Light TP220 SureGrip test probes
Rugged, high-intensity Xenon worklight
TL224 SureGrip test leads
TP280 test probe extenders
Attaches to a baseball cap Soft foldable pouch, keeps the entire
Includes a hat clip set together
Includes two AAA batteries
Waterproof

L206 Deluxe LED


Hat Light (hard hat not included)
Attach it to a hard hat, a baseball cap,
or even a panel door for all the light
you need
Three super bright white LEDsnever
burn out
L210 Probe Light and
L207 High-Intensity Light with Special hard-hat attachment included Probe Extenders
Limited Edition Fluke Cap 40-hour battery life
Includes three AAA batteries 8 in. probe extenders fit modular
Includes L205 Mini Xenon worklight test probes
Black baseball-style cap with Probe and extender length complies
Fluke logo with NFPA recommendations
Light is waterproof Bright white LED illuminates
Includes two AAA batteries contact area
Probe light fits on extender or
test probe

56 Accessories For more information, go to www.fluke.com/accessories


Fluke specialty
accessories and software

Extend the utility of your multimeter

Logging software Stray voltage Fiber optics

FOM Fiber Optic Meter


The Fluke Fiber Optic Meter (FOM)
helps you test and maintain fiber optic
SV225/10PAK cable without having to buy a whole
Eliminates stray voltage due to new meter. Plug the FOM directly into
capacitance between wires in electrical any DMM with a mV dc funtion and a
installations 10 mW input impedance, and quickly
Compatible with all instruments and and accurately verify fiber optic cable
test leads that accept standard 4 mm system loss. Light sources and patch
shrouded banana connectors cords sold separately.
Pack of 10
FlukeView Forms
Harness the power of the data logging Pressure and vacuum
function on your Fluke Digital Multimeter,
Thermometer or ProcessMeter. Log live
readings while connected to a PC, or
leave your Fluke 289, 789 or 54-II in
place to capture up to 1,000 readings for
download to a PC. FlukeView Forms easy-

to-use wizards allow you to download


readings from your Fluke tool and store
and display individual readings or a series FOS 850 and FOS 850/1300
of measurements. Spot trends and docu-
ment interruptions or spikes. Use standard Fiber Optic Light Sources
forms or the FlukeView Designer feature A variety of LED light sources allow
PV350 Pressure Vacuum Module

to customize reports using your specific you to test different cables.


data or company logo. Free demo-reader
Digital pressure and vacuum measure-
ments in a single module
download allows co-workers or clients to
open your report and interact with cap-
Measures HVAC/R, hydraulic and
pneumatic pressures to 350 psig/
tured data. 2413 kPa (usable to 500 psig)
Choose the model thats right for you: Measures to 76 cm Hg (29.9 in Hg)
FVF-SC1: Includes software and cable vacuum (not intended for measuring
used with 53-II and 54-II Thermometers microns of vacuum)
and 87IV and 89IV DMMs Compatible with most digital multimeters
FVF-SC2: Includes software and cable
used with 280 Series DMMs and 789 H900 Test Lead Holder
ProcessMeters, and the 1550B Insulation
Tester
Heavy duty construction with
mounting holes
FVF-SC3: Includes software and cable Holder has 10 slots for wires up to
used with 45 Bench Meters 8 mm in diameter
FVF-SC4: Includes software and Over-all dimensions: 27.9 cm L x
cable used with 8845A and 8846A 8.9 cm W x 3.2 cm H
Multimeters
Go to www.fluke.com/flukeviewforms to
One-year warranty
download the demo.

FlukeView Forms Basic


An abridged version of FlukeView Forms.
Analyze and share data with the provided
standard forms. Available for use with 280
Series DMMs and 789 ProcessMeters, only.
Upgrade to the full FlukeView Forms with
FVF-UG.

For more information, go to www.fluke.com/accessories Accessories 57


Fluke current clamps
For use with DMMs, ScopeMeters AC only models
and power quality analyzers

AC current clamp specifications


i200 i200s i400 i400s i800 i1000s i3000s i2000 flex i3000s flex
AC current range 1 A to 200 A 1 A to 200 A 1 A to 400 A 0.5 A to 1 A to 600 A 0.2 A to 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A
400 A 1000 A
Accuracy < 3 % +0.5 < 1 % +0.5 A 2 % + 0.06 A .5 A to 40 A, 2 % of rdg., 0.2 to 10 A: 1 to 30 A: 1 % of 1 % of
A48 to 65 Hz 48 Hz to
65 Hz
45 Hz to
400 Hz
2% + 50 Hz to 1 kHz
.015 A, 5 A to 3 % of rdg.,
3 %+0.1 A
10 A to
2 % + 0.1 A 1
to 300 A:
range
45 to 65 Hz
range, 45 Hz
to 65 Hz
i200s
400 A, 2 % + (typical) 100 A: 2 % + 0.5 A Ranges: 20 Ranges:
.04 A, 45 to 30 Hz to 50 Hz 2 %+0.5 A 1 to 3000 A: A, 200 A, 30 A, 300 A,
400 Hz and 1 kHz to 100 A to 2%+2A 2000 A 3000 A
10 kHz 1000 A: 48 to 65 Hz
1 %+1 A
48 to 65 Hz
Bandwidth (-3 dB) 40 Hz to 40 Hz to 5 kHz to 5 Hz to 10 Hz to 5 Hz to 10 Hz to 10 Hz to 10 Hz to
40 kHz 40 kHz 20 kHz 10 kHz 50 kHz 100 kHz 100 kHz 20 kHz 50 kHz
Maximum conductor 20 mm 20 mm 32 mm 32 mm 50 mm 54 mm 64 x 100 mm 177 mm (7 in) 177 mm (7 in)
diameter (0.8 in) (0.8 in) (1.25 in) (1.25 in) (1.98 in) (2.13 in) (2.52 x 3.94 in) or 265 mm
(10.4 in) i400s
Maximum 300 MCM 300 MCM 750 MCM 750 MCM 2-500 MCM 2-500 MCM 64 mm 610 mm 610 mm or
conductor size or 1-1000 or 1-1000 (2.52 in) (24 in) 915 mm
MCM MCM circumference circumference
Output levels 1 mA/A 10 mV/A 1 mA/A 10 mV/A 1 mA/A 1 mV/A 10 mV/A 100 mV/A 100 mV/A
100 mV/A 1 mV/A 10 mV/A 10 mV/A 1 mV/A 10 mV/A 10 mV/A
100 mV/A 0.1 mV/A 1 mV/A 1 mV/A
Output cable 1.5 m 2 m to BNC 1.5 m 2.5 m to BNC 1.2 m 1.6 m to BNC 2.1 m to BNC 2 m with 2.1 m to BNC
shrouded termination shrouded termination shrouded termination termination double termination
banana plugs banana plugs banana plugs shrouded
banana plugs
Warranty One-year One-year One-year One-year One-year One-year One-year One-year One-year
Safety rating CAT III 600 V CAT III 600 V CAT III CAT III CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V
1000 V
CAT IV 600 V
1000 V
CAT IV 600 V
i800

AC clamp-on current probe compatibility


Meter i200 i200s i400 i400s 80i-600A i1000s i3000s i2000 FLEX1 i3000s FLEX
10/11/12/12B/16/18 1 A to 1 A to 0.2 A to 1 A to 2 A to 3 A to
200 A 400 A* 1000 A* 3000 A 2000 A 3000 A
110/111/112 3 A to 30 A to 3 A to 30 A to 3 A to 3 A to
200 A 400 A* 1000 A* 3000 A 2000 A 3000 A i1000s
114/116 1 A to 0.6 A to 0.2 A to 1 A to 2 A to 3 A to
200 A 400 A* 1000 A* 3000 A 2000 A 3000 A
115/117 60 A to 1 A to 60 A to 0.6 A to | 60 A to 0.2 A to 1 A to 2 A to 3 A to
200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
21/23/73/75/77 1 A to 1 A to 1 A to 1 A to 1 A to 0.2 A to 1 A to 2 A to 3 A to
Series III 200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
26/79 Series III 1 A to 1 A to 1 A to 40 A & 2 A to 1 A to 40 A & 0.2 A to 2 A to 2 A to 3 A to
40 A 200 A 200 A to 400 A 400 A* 200 A to 400 A 1000 A* 3000 A 2000 A 3000 A
27 1 A to 1 A to 1 A to 1 A to 1 A to 0.2 A to 1 A to 2 A to 3 A to
200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
70 Series III 1 A to 1 A to 0.2 A to 1 A to 2 A to 3 A to
200 A 400 A* 1000 A* 3000 A 2000 A 3000 A
175/177/179 3 A to 1 A to 3 A to 1 A to 3 A to 0.3 A to 3 A to 2 A to 3 A to i2000 flex
200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
1577/1587 3 A to 1 A to 3 A to 3 A to 3 A to 0.3 A to 3 A to 2 A to 3 A to
Insulation Meter 200 A 200 A 400 A 400 A* 400 A 1000 A* 3000 A 2000 A 3000 A
83III/83V/88V 2 A to 1 A to 2 A to 1 A to 2 A to 0.2 A to 1 A to 2 A to 3 A to
200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
85/87 Series III 2 A to 1 A to 2 A to 2 A to 2 A to 0.2 A to 2 A to 2 A to 3 A to
87 Series V 200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
87/89 Series IV 2.5 A to 1 A to 2.5 A to 0.5 A to 2.5 A to 0.2 A to 1 A to 2 A to 3 A to
187/189 200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
287/289 1 A to 1 A to 1 A to 0.5 A to 1 A to 0.2 A to 1 A to 2 A to 3 A to
200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
8060A/8062A 2 A to 1 A to 2 A to 2 A to 2 A to 0.2 A to 2 A to 2 A to 3 A to
DMMs 200 A 200 A 400A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A i3000s flex
860 Series Graphical 1 A to 1 A to 1 A to 3 A to 1 A to 0.3 A to 3 A to 2 A to 3 A to
Multimeters 200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
39/41B Power 1 A to 1 A to 0.2 A to 1 A to 2 A to 3 A to
Meter 200 A2 400 A2 1000 A2 3000 A2 2000 A2 3000 A2
43B Power 1 A to 0.5 A to 0.2 A to 1 A to 2 A to 3 A to
Quality Analyzer 200 A 400 A 1000 A 3000 A 2000 A 3000 A
434/435 Power 1 A to 1.2 A to 0.3 A to 1.2 A to Best to use Best to use
Quality Analyzer 200 A 400 A 1000 A 3000 A i430Flex i430Flex
9X ScopeMeter 1 A to 1 A to 0.2 A to 1 A to 2 A to 3 A to
Series 200 A 400 A 1000 A 3000 A 2000 A 3000 A
120 Series 1 A to 2.5 A to 0.25 A to 2.5 A to 2 A to 3 A to i310s
ScopeMeters 200 A 400 A 1000 A 3000 A 2000 A 3000 A
190 Series 1 A to 1 A to 0.2 A to 1 A to 2 A to 3 A to
Scopemeters 200 A 400 A 1000 A 3000 A 2000 A 3000 A
45 DMM 1.5 A to 1 A to 1.5 A to 1.5 A to 1.5 A to 100 A 0.15 A to 1.5 A to 2 A to 3 A to
100 A 200 A 100 A 400 A* & 1000 A* 3000 A 2000 A 3000 A
500 A to 600 A
8808A 1 A to 1 A to 1 A to 0.5 A to 1 A to 0.2 A to 1 A to 2 A to 3 A to
200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
8845A/8846A 1 A to 1 A to 1 A to 1 A to 1 A to 0.2 A to 1 A to 2 A to 3 A to
200 A 200 A 400 A 400 A* 600 A 1000 A* 3000 A 2000 A 3000 A
74X Series Process 1.1 A to 11 A to 1.1 A to 11 A to 2 A to 3 A to
Calibrators 200 A 400 A* 1000 A* 3000 A 2000 A 3000 A
787/789 Process 50 A to 1 A to 50 A to 2 A to 50 A to 0.2 A to 2 A to 2 A to 3 A to i6000s
Meters 200 A 200 A 400 A 400 A* 440 A 1000 A* 3000 A 2000 A 3000 A
6 A to 6000 A
* Requires PM9081/001 Adapters.
1
Three range version.
Compatible with most
2
Current and watt readings will be multiples of 10 higher or lower than actual on some ranges. products except 434/435

58 Accessories For more information, go to www.fluke.com/accessories


Fluke current clamps
For use with DMMs, ScopeMeters AC/DC models
and Power Quality Analyzers

AC/DC current clamp specifications


80i-110s i410 i1010 i30 i30s i310s
DC range 0.1 A to 100 A 1 to 400 A 1 to 1000 A 30 mA to 30 A 30 mA to 30 A 0.1A to 450A
AC range 0.1 A to 70 A 1 A to 400 A 1 A to 600 A 30 mA to 20 A rms 30 mA to 20 A rms 0.1A to 300A
Accuracy 0.1 A to 10 A; dc to 3.5 % + 0.5 A for dc or 2 % + 0.5 A for dc or 1 % of reading, 1 % of reading, 30 A range: 1 % +
1 kHz: 3 % + 50 mA; ac (45 to 400 Hz) ac (45 to 400 Hz) 2 mA 2 mA 50 mA 80i-110s
up to 100 A add 15 %; 300 A range: 1 % +
up to 20 kHz add 12 % 300 mA
Bandwidth (-3 dB) 100 kHZ 3 kHz 10 kHz dc to 20 kHz (-0.5 dB) dc to 100 kHz (-0.5 dB) DC to 20 kHz
Zero error adjustment Yes Yes Yes Yes Yes Yes
Maximum conductor 11.8 mm (0.46 in) 30 mm (1.18 in) 30 mm (1.18 in) 19 mm (0.75 in) 19 mm (0.75 in) 19 mm (0.75 in)
diameter
Maximum conductor 1 AWG 750 MCM or 2-500 750 MCM or 2-500 250 MCM 250 MCM 250 MCM
size MCM MCM
Output levels 10 mV/A, 100 mV/A 1 mV/A 1 mV/A 100 mV/A 100 mV/A 10 mV/A, 100 mV/A
Output cable 1.6 meter with BNC 1.2 meter with 1.2 meter with 1.5 meter with 2 meter with BNC 2 meters with BNC
termination shrouded banana shrouded banana shrouded dual termination termination and a BNC i410
plugs plugs banana plue to safety shrouded
banana adapter
Battery life 40 hours 60 hours 60 hours 30 hours 30 hours 30 hours
Warranty One-year One-year One-year One-year One-year One-year
Safety CAT II 600 V; CAT III 600 V CAT III 600 V CAT III 300 V CAT III 300 V CAT III 300 V
CAT III 300 V

AC/DC clamp-on current probe compatibility


Meter 80i-110s i410 i1010 i30 i30s i310s i1010
10/11/12/12B/16/18 0.1 A to 100 A dc/ 5 A to 400 A dc/ 5 A to 1000 A dc/ 40 mA to 30 A dc/ 40 mA to 30 A dc/ 0.4 A to 450 A dc/
0.1 A to 70 A ac* 7 A to 400 A ac 7 A to 600 A ac 60 mA to 20 A ac 60 mA to 20 A ac 0.6 A to 300 A ac
110/111/112 0.14 A to 100 A dc/ 5 A to 400 A dc/ 5 A to 1000 A dc/ 40 mA to 30 A dc/ 40 mA to 30 A dc/ 0.4 A to 450 A dc/ i30s and i30
3 A to 70 A ac* 300 A to 400 A ac 300 A to 600 A ac 3 A to 20 A ac 3 A to 20 A ac 30 A to 300 A ac
114/115/116/117 0.1 A to 100 A dc/ 1.4 A to 400 A dc/ 1.4 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
Hall Effect AC/DC
0.1 A to 70 A ac* 6 A to 400 A ac 6 A to 600 A ac 60 mA to 20 A ac 60 mA to 20 A ac 0.6 A to 300 A ac Current Clamps
21/23/70/73/75/77
Series III
0.1 A to 100 A dc/
0.1 A to 70 A ac*
1 A to 400 A dc/
5 A to 400 A ac
1 A to 1000 A dc/
5 A to 600 A ac
30 mA to 30 A dc/
40 mA to 20 A ac
30 mA to 30 A dc/
40 mA to 20 A ac
0.1 A to 450 A dc/
0.4 A to 300 A ac
Especially useful for
26/79 Series III 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
low current measure-
0.2 A to 70 A ac* 20 A to 400 A ac 20 A to 600 A ac 200 mA to 20 A ac 200 mA to 20 A ac 2 A to 300 A ac ments down to 30
27 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/ milliamps
0.1 A to 70 A ac* 1 A to 400 A ac 1 A to 600 A ac 30 mA to 20 A ac 30 mA to 20 A ac 0.1 A to 300 A ac
77-IV 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
0.1 A to 70 A ac* 5 A to 400 A ac 5 A to 600 A ac 40 mA to 20 A ac 40 mA to 20 A ac 0.4 A to 300 A ac
175/177/179 0.11 A to 100 A dc/ 1.6 A to 400 A dc/ 1.6 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
0.3 A to 70 A ac* 30 A to 400 A ac 30 A to 600 A ac 300 mA to 20 A ac 300 mA to 20 A ac 3 A to 300 A ac
1577/1587 0.1 A to 100 A dc/ 1.2 A to 400 A dc/ 1.2 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
Insulation Meter 0.3 A to 70 A ac* 30 A to 400 A ac 30 A to 600 A ac 300 mA to 20 A ac 300 mA to 20 A ac 3 A to 300 A ac
83-III/83-V/88-V 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
0.1 A to 70 A ac* 1 A to 400 A ac 1 A to 600 A ac 30 mA to 20 A ac 30 mA to 20 A ac 0.1 A to 300 A ac i30s
85-III/87-III/87-V 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
0.2 A to 70 A ac* 20 A to 400 A ac 20 A to 600 A ac 200 mA to 20 A ac 200 mA to 20 A ac 2 A to 300 A ac
87-IV/89-IV/ 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
187/189 0.1 A to 70 A ac* 2.5 A to 400 A ac 2.5 A to 600 A ac 30 mA to 20 A ac 30 mA to 20 A ac 0.25 A to 300 A ac
287/289 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
0.1 A to 70 A ac* 1 A to 400 A ac 1 A to 600 A ac 30 mA to 20 A ac 30 mA to 20 A ac 0.1 A to 300 A ac
8060A/8062A 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
DMMs 0.2 A to 70 A ac* 20 A to 400 A ac 20 A to 600 A ac 200 mA to 20 A ac 200 mA to 20 A ac 2 A to 300 A ac
860 Series Graphical 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/ i30
Multimeters 0.3 A to 70 A ac* 30 A to 400 A ac 30 A to 600 A ac 300 mA to 20 A ac 300 mA to 20 A ac 3 A to 300 A ac
39/41B Power Usable but will read 1 A to 400 A ac** 1 A to 600 A ac** Usable but will read Usable but will read Not specd for dc
Meter 10 or 100 times Not specd for dc Not specd for dc 100 times higher** 100 times higher 0.6 A to 300 A ac
higher
9X ScopeMeter 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/ Power quality ac
Series 0.1 A to 70 A ac 5 A to 400 A ac** 5 A to 600 A ac** 50 mA to 20 A ac** 50 mA to 20 A ac 0.5 A to 300 A ac
123/124 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
combo packs
ScopeMeters 0.25 A to 70 A ac 25 A to 400 A ac** 25 A to 600 A ac** 250 mA to 20 A ac** 250 mA to 20 A ac 2.5 A to 300 A ac for 4-phase current
190 Series
Scopemeters
0.1 A to 100 A dc/
0.1 A to 70 A ac
1 A to 400 A dc/
5 A to 400 A ac**
1 A to 1000 A dc/
5 A to 600 A ac**
30 mA to 30 A dc/
50 mA to 20 A ac**
30 mA to 30 A dc/
50 mA to 20 A ac
0.1 A to 450 A dc/
0.5 A to 300 A ac
measurements
45 DMM 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc 30 mA to 30 A dc 0.1 A to 450 A dc/
0.15 A to 70 A ac* 15 A to 400 A ac 15 A to 600 A ac 150 mA to 20 A ac 150 mA to 20 A ac 1.5 A to 300 A ac
8808A 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
0.1 A to 70 A ac* 2 A to 400 A ac 2 A to 600 A ac 30 mA to 20 A ac 30 mA to 20 A ac 0.2 A to 300 A ac
8845A/8846A 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
0.1 A to 70 A ac* 1 A to 400 A ac 1 A to 600 A ac 30 mA to 20 A ac 30 mA to 20 A ac 0.1 A to 300 A ac
705/707 0.1 A to 100 A dc, 4 A to 400 A dc, 4 A to 1000 A dc, 40 mA to 30 A dc, 40 mA to 30 A dc, 0.4 A to 450 A dc,
No ac* No ac No ac No ac no ac No ac
715 0.1 A to 100 A dc, 4 A to 400 A dc, 4 A to 1000 A dc, 40 mA to 30 A dc, 40 mA to 30 A dc, 0.1 A to 450 A dc,
No ac* No ac No ac No ac no ac No ac
i430flex 4-pack***
74X Series Process 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 30 mA to 30 A dc/ 0.1 A to 450 A dc/
Calibrators 1.1 A to 70 A ac* 110 A to 400 A ac 110 A to 600 A ac 1.1 A to 20 A ac 1.1 A to 20 A ac 11 A to 300 A ac
787/789 Process 0.1 A to 100 A dc/ 1 A to 400 A dc/ 1 A to 1000 A dc/ 30 mA to 30 A dc/ 3 mA to 30 A dc/ 0.1 A to 450 A dc/
Meters 0.2 A to 70 A ac* 20 A to 400 A ac 20 A to 600 A ac 200 mA to 20 A ac 200 mA to 20 A ac 2 A to 300 A ac

* Requires PM9081 Adapter


** Requires PM9082/001 Adapter
***Only for use with the 430 Series Power Quality Analyzers

i5sPQ3

For more information, go to www.fluke.com/accessories Accessories 59


Fluke temperature
accessories

Hot probes with cool designs

SureGrip temperature
accessories
The innovative SureGrip design
from Fluke is now available in select
temperature probes. The soft rubber
handle combined with a new ergo-
nomic shape is so comfortable
to hold that youll forget about
the probe and focus on the
measurement. All SureGrip
probes have an improved,
more flexible strain relief The right tool for the job
Soft rubber
for a long life. Make better temperature measurements
handle provides with a probe designed for your application.
a secure grip The 80PK-8 pipe clamp probe (shown) is
specifically designed for measuring pipe
temperatures, calculating superheat and
sub-cooling for refrigeration troubleshoot-
ing. Other special purpose probes shown
Cleans up with are designed for making quick surface,
soap and water fluid and air temperature measurements.
The piercing probe makes it possible to
make temperature measurements below
the surface of a soft object. To enable your
Fluke DMM or 50 Series II thermometer
to make its best possible measurements,
chose the correct probe from the selection
guide below.

General Industrial
Bead Bead HVAC Immersion Surface Air Piercing Pipe clamp
purpose surface

80PK-1 80PK-25
80BK-A 80PK-11 80PK-22 80PK-3A 80PK-24 80PK-26 80PK-27 80PK-8
80PJ-1 80PT-25
K Type: -40 C
Lowest temp -40 C (-40 F) -30 C (-22 F) -40 C (-40 F) 0 C (32 F) -40 C (-40 F) (-40 F) T Type: -40 C (-40 F) -127 C (-196 F) -29 C (-20 F)
-196 C (-321 F)
Highest temp 260 C (500 F) 105 C (221 F) 1090 C (1994 F) 260 C (500 F) 816 C (1500 F) 350 C (662 F) 816 C (1500 F) 600 C (1112 F) 149 C (300 F)
K type wire with K type sensor 316 Stainless K type sensor
Probe material Velcro Inconel 600 Inconel 304 Stainless Steel
teflon insulation with teflon body Steel with pvc body
for pipes from
21.27 cm 9.525 cm 21.59 cm 10.16 cm 21.57 cm 20.32 cm 6.4 mm (.25 in)
Probe length 1 m Lead Wire 19 m Velcro cuff
(8.375 in) (3.75 in) (8.5 in) (4 in) (8.5 in) (8 in) to 34.9 mm
(1.375 in)
Cable length 1 m (39 in) 1.3 m (4 ft) 1 m (39 in)
Standard
Connection Molded Thermocouple Plug
Banana Jack
SureGrip handle No No No Yes No Yes Yes Yes Yes No
Low conductiv- Clamps securely
Velcro probe Exposed junc- Probe material
Perforated baffle Use for general ity stainless to pipe.
Ideal for initial troubleshooting. allows For use in tion for direct safe for use in
for air and purpose air or steel minimizes Measurements
Key feature Can be secured in place with a hands free liquids or in contact with foods. Sharp tip
non-caustic gas surface mea- thermal shunt- are repeat-
magnet. temperature gels. flat or slightly pierces solid
measurements surements ing. Extra able to 0.56 C
measurement. convex surfaces. surfaces..
rugged. (1 F).
Thermocouple
K K, J K K K, T K
types
Typical use
General purpose
HVAC
Food service
Industrial
Residential
Commercial

Use an 80AK adapter with meters with temperature function such as the 16, 78, 83V, 87V, 88V, 179, 187 and 189
The 80TK enables your meter to read temperature using mV (see the Accessory selection guide on page 60 for meters)
For the Fluke Thermometer, 51, 52, 53, and 54 III, no adaper is necessary for thermocouple types K, J, T and E

60 Accessories For more information, go to www.fluke.com/accessories


Fluke Temperature
accessories
Turn your digital multimeter
into a thermometer

Thermocouple
Other temperature accessories
Plug Kits
80TK Thermocouple Module 80CK-M and 80CJ-M 700TC1
Converts K-Type thermocouple Type K and J Male A kit of 10 mini-plug
connectors. One each
signals into mV output Mini-Connectors
Connects to DMM via Isothermal screw terminal of the following:
Type J (black)
standard banana plugs for K or J wire
Switch selectable C or F Suitable for up to 20 Type K (yellow)
Range: -50 C to 1000 C gauge thermocouple wire
Type T (blue)
Type E (purple)
(-58 F to 1832 F)
Includes 80PK-1 probe Color coded to industry Type R/S (green)
standards (K-yellow,
Type B or Cu (white)
J-black)
Type L (J-DIN) (blue)
80T-150U Universal Solid State Two per package
Type U (T-DIN) (brown)
Temperature Probe
Type C (red)
For measurement of air, surface 80PJ-EXT, 80PK- Type N (orange)
and non-corrosive materials EXT, 80PT-EXT
Measurement range: Thermocouple Wire 700TC2
-50 C to 150 C
(-58 F to 302 F)
Extension Kits A kit of 7 mini-plug
For extending and connectors.
Output: 1 mV/C or 1 mV/F
repairing J, K or T-type Type J (black), two
(switch selectable)
thermocouple wires. Type K (yellow), two
Connects to DMM via standard banana plugs
Kit includes 3 m (approx. Type E (purple), one
9 ft.) of thermocouple Type T (blue), one
80AK-A DMM Adapter wire and 1 pair of Type R/S (green), one
Adapts K-type thermocouple male/female
mini-connector to dual banana mini-connectors
plug inputs
Compatible with all Fluke Maximum continuous 80PR-60 RTD
exposure temperature: Temperature
DMMs with temperature 260 C (500 F)
measurement functions Probe
Measurement range and accuracy 80PK-EXT is compatible
Resistance
with K-type thermometers; temperature
is not affected by the 80AK-A adapter 80PJ-EXT is designed for detector probe
J-Type thermometers, and designed to
80BK-A Integrated DMM 80PT-EXT is designed for add contact
Temperature Probe T-type thermometers measurements to your
Compatible with all Fluke DMMs Fluke 66 and 68 Non-Contact Infrared
with temperature measurement Thermometers
functions
K-Type thermocouple with Measurement range: -40 C to 260 C
(-40 F to 500 F)
standard banana jack
Convenient one-piece construction 3.5 mm phono type jack is only
appropriate for Fluke 66 and 68
Measurement range: -40 C to 260 C Thermometers
(-40 F to 500 F)

Process tools accessories


BP7217 700PTP-1 Pneumatic 700PMP Pressure
NiCd rechargeable battery; Test Pump Pump
nominal 7.2 volt, 1700 mA hr The Fluke 700PTP is a hand- The 700PMP is a hand-
Use in 867B meters or 700 held pressure pump designed operated pressure pump
and 740 Series Calibrators to generate either vacuum to to provide pressures up to
-11.6 psi/-0.8 bar or pressure 150 psi/1000 kPa. Output
BP7235 to 600 psi/40 bar. fitting is 1/8 FNPT.
NiMH rechargeable battery;
nominal 7.2 Volt, 3500 mA hr
Use in 700 and 740 Series Fluke 700-IV Current
Calibrators
Shunt
700HTP-1 Hydraulic Conversion factor:
700LTP-1 Low Pressure Test Pump 10 mV = 1 mA
Test Pump The Fluke 700HTP is designed Accuracy (% of input,
Hand operated pressure pump to generate pressures up 1 year): 0.025 %
designed to generate either to 10,000 psi/700 bar. Use the Input current:
vacuum to -13 psi/-.90 bar or Fluke-700PRV adjustable 0 to 55 mA
pressures to 100 psi/6.9 bar. relief valves to limit pressures Input resistance:
Ideal for low pressure applica- from 1360 psi to 5450 psi. 250 W nominal
tions requiring accurate low Output resistance:
pressure testing. 10 W nominal
Accuracy specification
700ILF In-line Filter 700HTH Hydraulic applies from +18 C and
The Fluke 700ILF can be used Test Hose 28 C to 50 C
to isolate the calibrator from The 700HTH is a 10,000 Maximum input voltage:
incidental contact with fluids. psi, 700 bar test hose that 30 V dc
Particularly useful with the 718 connects to a calibration
calibrator to help keep moisture unit under test from a Fluke
or oils from contaminating the 700HTP hydraulic test pump.
on-board pump.

For more information, go to www.fluke.com/accessories Accessories 61


Fluke cases and holsters
A premium meter deserves a
premium case

Premium case Soft cases Hard cases

C510 C25 C50 C90 C12A C115 C116 C43 C789 C20 C101
Genuine top Tough polyprophylene cases
Zippered carrying cases protect your meter; most cases come with
grade leather hold and protect meters and
belt loops so your meter is stored conveniently on your tool belt.
cowhide. accessories.
Dimensions 20.3 cm x 11.3 19.2 cm x 11 16.9 cm x 8.5 19.2 cm x 7.9 15.1 cm x 11.3 24.8 cm x 21.6 24.8 cm x 24.1 30.4 cm x 19.7 27.0 cm x 22.5 22.5 cm x 13.5 30.5 cm x 36
cm x 5.1 cm cm x 5.6 cm cm x 3.4 cm cm x 5.6 cm cm x 3.4 cm cm x 7 cm cm x 5.7 cm cm x 6.7 cm cm x 6.7 cm cm x 9.0 cm cm x 10.5 cm
(9 in x 5 in x (8.5 in x 4.9 in (7.5 in x 3.75 (8 in x 3.5 in (6.7 in x 5 in (9.75 in x 8.5 (9.75 in x 9.5 (13.5 in x 8.75 (12 in x 10 in (10 in x 6 in x (12 in x 14.2 in
2.25 in) x 2.5 in) in x 1.5 in) x 2.5 in) x 1.5 in) in x 2.75 in) in x 2.25 in) in x 3 in) x 3 in) 4 in) x 4.1 in)
DMMs
10/11/12/12B
110/111/112
16
21/23/26/

75/77/79
27
70/73 III
175/177
179
83/85/87

Series III
87/89 IV
83/87 Series V
287/289
187/189
Clamp meters
321/322
Insulation testers
1503/1507
1577/1587
Thermometers
50S/50D
51/52/53/54

Series II
61
65
Electrical testers
T3/T5
7-600/7-300
ScopeMeters
123/124/125
Power quality
39/41B
Process tools
705/707
712/713
714/715/716/717
725
741/743/744
787
789

C1600 Meter and C550 Tool Bag H6 Infrared Thermometer Holster


Accessories Gear Box Steel reinforced Durable nylon construction
This rugged, molded frame protects your thermometer
plastic case will Rugged ballistic while keeping it within reach
carry Fluke digital
cloth with heavy
duty hardware
For Fluke 63, 66 and 68 Infrared
Thermometers
multimeters, process
calibrators and most
Large zippered
H5 Electrical Tester Holster
storage compartment
Fluke accessories used with 25 pockets Rugged fabric holster
for these meters. Weather resistant includes flap for lead
Deep interior large enough Carry all your tools to the job storage and built-in
belt loop
to hold and protect your gear
Rubber gasket in lid seals out Fits Fluke T3 and T5 testers
dust and keeps contents dry C75 Accessory Case H3 Clamp Meter Holster
Lift out tray keeps everything Zippered carrying case with Rugged fabric holster includes
organized two inside pockets
flap for lead storage and
Carry test lead sets or probes built-in belt loop
For Fluke 320 and
330 Series Clamp Meters

62 Accessories For more information, go to www.fluke.com/accessories


Fluke holsters and fuses
Take care of your test tools MeterCleaner Wipes
inside and out Industrial strength cleaning
formula removes surface dirt,
oil and grease
ToolPak Magnetic Safe on rubber
Protective meter holsters
Meter Hanger Safe to the
environment
C10 Meter Holster Free both hands to make measurements Comes in
Snap on yellow holster Hang your meter from metallic surfaces two sizes:
absorbs shocks and pro- like panels and pipes 6-pack (MC6)
tects meter from rough
handling
Kit includes universal hanger clips and 50-pack
(two), hook and loop straps (two (MC50)
Fits Fluke 10 Series DMMs
lengths), adapter and strong magnet
Attaches to back of many Fluke meters,
including 110, 170, 180 Series, 87V
C70Y Meter Holster and 83V DMMs, 724, 725 and 789
Snap on yellow holster Process Calibrators, 70 Series III DMMs,
absorbs shocks and pro- 1503, 1507, 1577 and 1587 Insulation
tects meter from rough Multimeters and 50 Series II Digital
handling
Thermometers
Flex-Stand allows meter
to hang, lean or stand
for convenience and best
viewing Datacom tools
For Fluke 70 and 73
Meters IntelliTone Pro Toner and Probe
IntelliTone digital processing
eliminates noise and
false signals
H80M Protective
Holster with
New SmartTone
analog toning pre-
magnetic strap cisely isolates indi-
Snap on holster absorbs vidual wire pairs
shocks and protects meter
from rough handling
Locates cables safe-
ly and effectively on
Magnetic strap solution active networks
makes it easy to hang your Verifies twisted-pair
meter for hands free work installation with
For Fluke 80 Series visual end-to-end continuity test
DMMs, 710 Series and Identifies, diagnoses, and trouble-
787 calibration tools shoots datacom/telecom services

Test the integri-


ty of UTP, Coax,
phone and
security cabling
Fuse selection guide using known
Replacement fuses for Fluke DMMs are available from your distributor. To order direct from Fluke call standards.
1-800-44-FLUKE (U.S.) or email fluke-info@fluke.com.
MicroScanner2 Cable Verifier
Model Fuse Requirements
Graphical wiremap, length,
cable ID, and distance to
21-III/75-III/73-III P/N 871173 630mA 250V fuse fault displayed on one screen
P/N 803293 11A 1000V fuse Tests all common media
27 (S/N<7247001) P/N 871173 630mA 250V fuse types including RJ11, RJ45,
P/N 871202 3A 600V fuse Coax, with no need for
P/N 892583 15A 600V fuse adapters
27 (S/N>7247001 P/N 943121 440mA 1000V fuse Locates virtually any cable or
wire pair with IntelliTone digital and
P/N 803293 11A 1000V fuse
analog toning
83/85/87 (S/N>6565000) P/N 943121 440mA 1000V fuse
P/N 803293 11A 1000V fuse
Detects media services, including
10/100/1000 Ethernet, POTS, and PoE
83-III/85-III/87-III 87-IV/89-
IV/187/189/287/289/77-III/79-III/23-III/26-
P/N 943121 440mA 1000V fuse
P/N 803293 11A 1000V fuse
Dntegrated rubber holster enhances
grip and makes it durable enough for
III/175/177/179/77-IV the toughest jobs
111/112/115/117 P/N 803293 11A 1000V fuse Large, backlit LCD makes results crystal
1577/1587 P/N 943121 440mA 1000V fuse clear whether in bright sunshine or in
a dark closet
1503/1507 P/N 2279339 315mA 1000V fuse
787/789 P/N 943121 440mA 1000V fuse (Qty 2)
MicroMapper
The fast, comprehensive
LAN wiremap checker
Tests twisted-pair cables for
opens, shorts, crossed pairs,
split pairs, or any miswires
Verifies correct pin outs,
wiremap

For more information, go to


www.flukenetworks.com

For more information, go to www.fluke.com/accessories Accessories 63


Whats New from Fluke

Fluke Ti25 and Ti10 Thermal Imagers


Built for tough work environments, these high-performance,
fully-radiometric thermal imagers are ideal for every day trouble-
shooting of electrical systems, electro-mechanical equipment,
process equipment, and more.
Patent-pending IR-Fusion blends thermal and visible images,
only from Fluke.
Withstands a two meter drop and exposure to dust and water.
Clear, crisp images with excellent thermal sensitivity on a Fluke 8808A
widescreen display.
2 GB of memory. Digital Multimeter
Optimized for standardized production
New TiR and TiR1 Building Diagnostic models also available. test, this bench meter has:
For more information, see page 42.
Setup buttons for pre-programming
frequent manual measurements.
0.01 % basic V dc accuracy.
Fluke 289 and 287 True-rms Logging Multimeters Dual display.
These multimeters pack more accuracy and convenience into i-leakage, a sensitive low dc current,
a handheld multimeter than ever before, putting more problem high impedance range for measuring
solving power in your hands. standby current.
Unique on-screen logging and graphing with TrendCapture Split terminal jacks to perform 4-wire
no need to download to a PC to detect a trend. measurements with two leads.
Large VGA screen with simultaneous readings displayed. For more information, see page 15.
0.025 % basic accuracy and 200 hours of logging memory.
For more information, see page 7.

Fluke 771 Milliamp Process Clamp Meter


Measure, test, and troubleshoot 4-20 mA control signals
without breaking the mA loop or disrupting process control.
Best in class 0.2 % accuracy.
Resolution and sensitivity to 0.01 mA.
Dual display of both mA nad 0 to 100 % of 4-20 mA span.
Detachable clamp with extension cable.
For more information see page 36. Fluke. Keeping your world
up and running.

Fluke Corporation
PO Box 9090,
Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
Your authorized Fluke distributor
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa
+31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries
+1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com

2003-2007 Fluke Corporation.


Specifications subject to change without
notice. Microsoft is a registered trade-
mark of Microsoft Corporation. Printed in
U.S.A. 12/2007 1274458 C-US-N Rev Q
Volume 39