Introduction
Thank you for choosing the Matrix Eternity! Please read the instructions in this
quick start to install this feature reached System.
This Quick Start is meant to help you install the basic features and parameters
of the system. For advanced installation and detailed feature description,
please refer the Eternity System Manual provided to you on the CD-ROM.
It is possible to configure the Eternity using following interfaces:
Web interface (TCP/IP)
Telephonic interface (using SLT and DKP)
Serial Interface (RS-232)
Compared to the telephonic and serial interface, the Web interface is simpler
and more user friendly. Hence, we recommend the system engineer to use the
web interface to configure the Eternity.
* This Quick Start is applicable for software version V6R13 onwards.

Before You Start


Verify Package Content
Unpack the system. Make sure that your package contains all the below items.
If any item is missing or damaged, please contact the source from where you
have purchased the system.

Eternity Platform

3 Pin AC Mains cable

Quick Start and


User Card

RJ-45 Cable

CD containing Voice Messages, System Manual,


Quick Start and User Card.
Wall mounting nails
Matrix Logos
Support Card
Mounting Template
Telephone Personality Guide
Warranty Card
MDF cable for Switch Card (provided with Eternity ME only)

Installing the Eternity


Precautions
Ensure proper electrical earth and telecom earth for safety of personnel as
well as of the System.
Always wear properly earthed anti static belts while handling the cards of
the System.
Use Primary Protection on the trunk and long distance extension lines to
protect the system from lightning and electrical surges.
It is advisable that the system should be installed away from any source of
electromagnetic noise such as any radio equipment, heavy transformers,
faulty electric chokes of tube-lights, any device having a faulty coil etc. This
will reduce any problem arising due to electromagnetic effect.

Installation
Installing SLT, DKP and TWT Cards:
Unpack the SLT, TWT, DKP cards and insert them in the universal slots of
the Eternity.
Plug the MDF cable provided with each card in the MDF connector provided
on the front panel of the card.
Refer the cable connections given in the 'Appendix' to identify the ports and
terminate the open end of the cables in the main MDF.
Single Line Analog Telephone instruments can be connected to SLT port,
Digital Key phones viz. Eon45, Eon48, Eon42 and consoles viz. DSS64,
DSS72 and DSS16X4 can be connected to the DKP Port.
Two Wire Trunk (Analog Trunk) can be connected to TWT port.
Installing the BRI Card:
Refer below given information before inserting the BRI card in the system.
While installing the BRI Card in the Eternity ME
Use the MDF cable provided with the BRI card.
When the BRI port is to be used in the NT mode the Tx and Rx cable of BRI
port shall be crossed with Rx and Tx cables of the terminal respectively.
For using the BRI port in the TE mode, the cable connections shall need not
to be crossed.
While installing the BRI Card in the Eternity GE
While installing BRI card in the Eternity GE, you shall also set the Jumpers
given on the BRI Card as shown below to use them as NT/TE.
By default, all BRI ports are configured in TE Mode.
Mode
NT
TE

Jumper Position for Port1


J1
J2
J3
J4
BC
BC
BC
BC
AB
AB
AB
AB

Jumper Position for Port2


J6
J7
J8
J9
BC
BC
BC
BC
AB
AB
AB
AB

Jumper Position for Port3


J10
J16
J17
J18
BC
BC
BC
BC
AB
AB
AB
AB

Mode
NT
TE

Jumper Position for Port4


J14
J15
J19
J20
BC
BC
BC
BC
AB
AB
AB
AB

Above jumpers are on the Main Board.


Common points for installing the BRI card in Eternity-ME and GE
Depending on the requirement, each BRI Port can be configured in TE/NT
mode. It is possible to feed power to the terminal equipments connected to
the BRI port (Orientation type configured as Network) from the Eternity.
To feed the power on Tx and Rx wires, set the jumpers J1 and J2 of BRI
module in AB position.
To feed the power on separate pairs of wires, set the jumpers J1 and J2 of
BRI module in BC position.
To power the ISDN terminal from external power source, keep the jumpers
J1 and J2 open.
The jumpers J1 and J2 as are provided on the BRI module (daughter
board).
Number of ISDN terminals that can be connected on the BRI port
configured in NT mode depends on the power consumed by the ISDN
terminals. Maximum power that can be provided on one BRI port is 50mA.
However, from signaling point of view max 8 terminals can be connected
on the BRI port configured in NT mode. Hence, if the terminal equipments
do not consume power from the BRI port (configured in NT mode) of the
Eternity, maximum 8 terminals can be connected to it

Termination Resistance on the BRI Port


Termination of 100 Ohms should be inserted in following cases:
1.

When the BRI port is configured in NT mode.

2.

When the BRI port is configured in TE mode and connected in Point-toPoint configuration as shown in figure1.
Figure 1:
ISDN
Network

BRI
Line

NT
TE

Eternity

3.

When the BRI port is configured in TE mode and connected as last


terminal on the S0 bus (Multi-point configuration) as shown in figure 2.
Figure 2:
ISDN
Network

BRI
Line

NT

TE

TE

TE

Other
ISDN
Equipment

Other
ISDN
Equipment

Eternity

4.

Termination need not be inserted in case 2 and 3 above, if the S0 bus


itself supports Terminating resistors.

5.

Termination need not be inserted if BRI port of Eternity (configured in TE


mode) is connected as any terminal other than the last terminal on the S0
bus (Multi-point configuration).
To set the 100 termination on the BRI port set the Jumpers J3 and J4
(provided on the BRI module) in AB position.
To remove the 100 termination from the BRI port set the Jumpers J3
and J4 (provided on the BRI module) in BC position.

While Installing E&M Card

The E&M Card supports Type-4 and Type-5 connection.


To select the Type-4 connection for the E&M Port, set Jumpers J1 and J2
(given on E&M module) in AB Position.
To select the Type-5 connection for the E&M Port, set Jumpers J1 and J2
(given on E&M module) in BC Position.
By default, all the E&M Ports are set to support Type-4 connection.
The E&M port can be set for the 2-wire speech interface or 4 wire speech
interface as required.
To select 2-wire speech interface for the E&M Port, set Jumpers J3 and J4
(given on E&M module) in BC Position.
To select 4-wire speech interface for the E&M Port, set Jumpers J3 and J4
(given on E&M module) in AB Position.

While Installing GSM (Mobile) Card

Unpack the Mobile Card.


Connect the antenna (provided with the Mobile card) to the splitter
connector provided on the front panel of the Mobile card.

Following figure shows location of Mobile port in Mobile card.


Eternity GE GSM 4 Card:

GSM Module

GSM Module

SIM Holder SIM Holder

SIM Holder SIM Holder

Mobile3 Mobile4

Mobile1 Mobile2

Euro Connector

Eternity ME GSM 8 Card

GSM Module

GSM Module

GSM Module

GSM Module

SIM Holder SIM Holder

SIM Holder SIM Holder

SIM Holder SIM Holder

SIM Holder SIM Holder

Mobile7

Mobile8

Mobile5

Mobile6

Mobile3

Mobile4

Mobile2

Mobile1

Euro Connector

Refer following steps before installing SIM cards in the Mobile Ports.

Installing SIM in GSM Mobile Port

If you want to use PIN Protection


If it is desired to use the PIN Protection, install the SIM card in
your Mobile handset and enable the PIN Protection.
From the Mobile handset change the PIN to 1234.
Remove the SIM from the Mobile handset and insert in the Mobile
Port of the Eternity.
Installing the SIM with PIN Value 1234, enables you to change
the SIM PIN from the Eternity later on.

If you don't want to use PIN Protection


Insert the SIM in the Mobile handset and make sure that the PIN
Protection is disabled.
Remove the SIM Card from the Mobile handset and install in the
Mobile port of the Eternity.

Installing RUIM CDMA Mobile Port

It is strongly recommended to not to use PIN protection facility for the


Mobile port, used as CDMA.

Using CDMA Mobile Handset, make sure that PIN Protection is


disabled in RUIM.
Do not use PIN Protection enabled RUIM in Eternity, the RUIM might
get blocked.

LED indications for the Mobile Port would be as shown below:


Event

Colour

Port Disable
Port Idle
Port Active (All
states other than
Ring and Speech)

Cadence in msec (1 cadence is of 3000


msec)
LED Off
LED Off

RED

Continuous ON

Ring Event

GREEN

Speech

GREEN

400ms ON-200 ms OFF-400ms ON-200 ms


OFF
Continuous ON

Module Initialization ORANGE

200ms On-200ms Off-200ms On-200ms Off200ms On-200ms Off-200msOn-200ms Off200ms On-1200ms Off (5 Blinks)

PUK required

ORANGE

200ms On-200ms Off-200ms On-200ms Off200ms On-200ms Off-200msOn-1600ms Off

SIM PIN faulty

ORANGE

200ms On-200ms Off-200ms On-200ms Off200ms On-2000ms Off (3 Blinks)

SIM Absent

ORANGE

200ms On-200ms Off-200ms On- 2400ms


Off (2 Blinks)

Network Link Down


(absence of
ORANGE
Network)

200 ms On-2800 ms Off (1 Blink)

If the points related to the PIN protection are not followed, your SIM card
can get blocked and it will require Personal Unblocking Number (PUK) to
reactivate it again.

While Installing VoIP Card

Unpack VoIP Card.


Insert VoIP Card in the universal slot of the system.
Connect one end of the RJ45 cable (provided with the VoIP card) to
Ethernet port of VoIP card and the other end with the LAN switch or broad
band Modem.

LED indications for the VoIP card would be as shown below:


VoIP Card supports 2 LEDs:

LED 1 Indicates the VoIP Cards Status.

LED 2 Indicate the status of the SIP Trunk, for which the LED is
assigned.
Indication of LED1 shall be:
Event
Booting up
Stack Construction in
progress
Stack Construction
Successful
VoPP Program Down Load
Fail
Stack Construct FailurePPPoE Authentication Fail
Stack Construct Failure-IP
Address Invalid

Colour
GREEN
GREEN
GREEN

Cadence
Continuous
200msON-200ms OFF200msON-200ms OFF
1 Sec ON-1 Sec OFF

RED

Continuous ON

RED

200ms ON-1sec OFF

RED

200ms ON-200ms OFF200ms ON-1sec OFF

Colour
RED
RED

Ca de nce
Continuous ON
200ms ON-1 Sec OFF
(continuous)

RED

200ms ON-200 ms OFF200 ms ON-1 Sec OFF


(continuous)
200 ms ON-1 Sec OFF
(continuous)
Continuous ON

Indication of LED2 shall be:


Eve nt
SIP Trunk-Disabled
Registration FailAuthentication Password
Invalid
Registration FailConfiguration Parameters
Invalid
Registration in Progress

GREEN

Registration successful

GREEN

While Installing the T1E1PRI Card

Unpack T1E1PRI Card.


By default, termination resistance of DS1 port set as 120, which is
for E1 connectivity.
To use the DS1 port for T1 connectivity, termination resistance shall be
changed to 100.

In Eternity ME

DS1 Port -1s termination resistance can be changed using DIP switch
SW5.
Set Pins of SW5 as shown below to set termination resistance.
Pin-1
OFF
OFF

Pin-2
OFF
ON

Pin-3
ON
OFF

Pin-4
OFF
OFF

Resistance
120 Ohms (for E1)
100 Ohms (for T1)

DS1 Port 2s termination resistance can be changed using DIP Switch


SW2.
Set Pins of SW2 as shown below to set termination resistance.
Pin-1
OFF
OFF

Pin-2
OFF
ON

Pin-3
ON
OFF

Pin-4
OFF
OFF

Resistance
120 Ohms (for E1)
100 Ohms (for T1)

In Eternity GE

Termination resistance can be changed, using Jumper J5.


In default configuration Jumper J5 is set in AB Position to provide 120
termination resistance, which is for E1 connectivity.
If you want to use the DS1 Port for T1 connectivity set Jumper J5 in BC
position, which shall provide termination resistance of 100.
Connect one end of the RJ45 cable (provided with the T1E1PRI Card) to
the DS1 port and the other end to Modem provided by service provider.

LED indication of T1E1PRI Card of Eternity-ME and Eternity-GE are


shown below:
Eternity-ME

The Eternity ME T1E1PRI Card has four LEDs, viz . L1, L2, L3 and L4.
LED L1 and L2 are assigned to DS1 Port 1, while LED L3 and L4 are
assigned to DS1 Port 2.
LED L1 shows Card Heart Bit as well as status of the PORT1.

Eternity-GE

The Eternity-GE T1E1PRI Card has 2 LEDs, viz. LED1 and LED2.
LED patterns are defined as shown below for different state and signaling
as shown below.

1. Port Active Mode

Signaling Type: E1-PRI


LED1/LED3 Pattern:
PORT Status
Layer 1 established
successfully
CRC4 Alarm
BFA Alarm
LOS Alarm
LED2/LED4 Pattern:
PORT Status
Layer 1 established
successfully
RAI Alarm
AIS or LOS Alarm

Colour
GREEN

Cadence
Continuous ON

GREEN
RED
RED

100ms ON-100 ms OFF


500ms ON-500 ms OFF
Continuous ON

Colour
GREEN

Cadence
Continuous ON

RED
RED

500ms ON-500 ms OFF


Continuous ON

Colour
GREEN

Cadence
Continuous ON

GREEN
RED
RED
RED

100ms ON-100 ms OFF


100ms ON-100 ms OFF
500ms ON-500 ms OFF
Continuous ON

Colour
GREEN

Cadence
Continuous ON

GREEN
RED
RED
RED

100ms ON-100 ms OFF


100ms ON-100 ms OFF
500ms ON-500 ms OFF
Continuous ON

Signaling Type: E1-CAS


LED1/LED3 Pattern:
PORT Status
Layer 1 established
successfully
CRC4 Alarm
MFA Alarm
BFA Alarm
LOS Alarm
LED2/LED4 Pattern:
PORT Status
Layer 1 established
successfully
Y-Bit Alarm
AIS16 Alarm
RAI Alarm
AIS or LOS Alarm

Signaling Type: T1-RBS or T1-PRI


LED1/LED3 Pattern:
PORT Status
No Alarm
TFA Alarm or MFA
Alarm
AIS Alarm
LOS Alarm
LED2/LED4 Pattern:
PORT Status
Layer 1 established
successfully
RAI or LOS Alarm

Colour
GREEN
RED

Cadence
Continuous ON
500ms ON-500 ms OFF

RED
RED

100ms ON-100 ms OFF


Continuous ON

Colour
GREEN

Cadence
Continuous ON

RED

Continuous ON

Colour
RED GREEN

Cadence
500 ms RED-500 ms
GREEN

2. Port Maintenance Mode


LED1/LED3 Pattern:
PORT Status
Maintenance Mode

LED2/LED4 Pattern:
PORT Status
Near end loop back wait
before activate
Near end loop active
Near end loop back wait
before deactivate
Far end loop back wait
after activate
Far end loop active
Far end loop back wait
after deactivate

Colour
RED

Cadence
100ms ON-100 ms OFF

RED
RED

Continuous ON
500ms ON-500 ms OFF

GREEN

100ms ON-100 ms OFF

GREEN
GREE

Continuous ON
500ms ON-500 ms OFF

Colour
RED

Cadence
Continuous ON

3. Port Disable Mode


LED1/LED3 Pattern:
PORT Status
Port Disable

LED2/LED4 Pattern:
PORT Status
Port Disable

Colour
Off

Cadence
Off

While Installing VMS Card

Unpack VMS Card.


Insert VMS Card in the universal slot of the system.
LED indication of VMS card In Eternity-ME and Eternity-GE are
shown below:
Condition
Colour
Cadence
Normal
Green
1 sec ON - 1 Sec Off
Disk Error
RED
100ms ON - 100ms OFF
File System Error
RED
Continuous ON

4. Switching ON the system

Switch ON the system, it takes 2 to 3 minutes for init.


On completion of the initialisation, LED L1 on master card/CPU card
will blink Green with cadence of 1Sec ON - 1 Sec OFF, continuously.

5. How to reach the Home Page of Web Server?


Connecting the Eternity with the computer

Connect the Ethernet Port of the Eternity to the Ethernet Port of the
Computer using the RJ-45 cable provided with the system.

The default IP Address of the Eternity is 192.168.1.1 and Subnet


Mask is 255.255.255.0.

To access the Eternity using computer, the Eternity and computer


shall be in the same subnet.

Follow below given steps to change the Eternitys IP Address and


Subnet Mask.
1. Dial 1#91-1234 (1234 is default SE Password) to enter in SE
Mode (from any SLT/DKP).
2. Issue command 2110-<IP Address>, to change IP Address
For example, issue command 2110-192168050010, to change
the IP Address as (192.168.50.10).
3. Issue command 2111-<Subnet Mask>, to change Subnet Mask.
4. Dial 00 to exit from SE Mode.
To change the IP Address and Subnet Mask of the Ethernet port of the
computer go to: My Network Places Properties Local Area
Connection Properties Internet Protocol (TCP/IP) Properties.
(For computers with windows 2000 and XP Operating Systems)

You may also connect the Eternity in the LAN of the organisation. But
make sure that the Eternity and the computer you are using to access the
Eternity are in the same subnet.

Configuring the Eternity using the Web Jeeves

Enter IP address of the Eternity in browsers address field.


The Eternity will prompt for login as shown below.

Log in as SE

Log in as SA

Log in as Front Desk User


Click on option to 'Log in as SE', if you are a System Engineer.
Feature Menu is displayed on the left side of Welcome page.

Click on Login button after entering valid User Password (default:


1234) for SE:

On successful log in, you will get 'Home Page'.

Now you can configure the Eternity Using Jeeves.


The left most side of all the Jeeves Page, contains link list.
Click on the link and the respective webpage will get opened.
Make required changes and click on Submit given on the bottom of
the webpage to affect the changes.

6. Select the Country (Region Code)


By default, the Country = India. Change the country code from the
webpage, System General Parameters, Parameter Name - Country.
Once you have selected the country, give SE command to default the
Eternity from the SLT/DKP as given below:
1.
2.
7.

Dial 1#91-SE Password to enter in SE Mode (from any SLT/DKP)


Issue command 5302-Reverse SE Password, to load the default
settings for the selected country.

Program the Emergency Numbers

Click on the link 'Emergency Numbers'.


First 5 entries of Emergency Number table are non-editable, you can
only assign the OG Trunk Bundle Group to route these numbers. The
default setting of Emergency Number table depends on the Region
you have selected.
In default setting, if you don't find emergency numbers recognised in
your region, program the same at in any index from 6 to 10 and
assign OG Trunk Bundle Group to route this number.
Make sure that trunk lines programmed in OG Trunk Bundle Group
assigned for Emergency Number, are capable of routing the
emergency number, otherwise the emergency services will get
affected.

8. Enterprise Name

Enterprise name of up to 80 characters can be programmed.


Refer, System General Parameters - Customer Name.

9. Time Zone - Automatic (Time Table), Manual Time Zone

By default, all the stations and trunks are assigned Time Table -1.
The default settings of the Time Table-1 is given below:

Working Hours 09:00 to 18:00

Break Hours 13:00 to 14:00

Non working hours: 18:00 to 09:00


Refer, Time Tables to make changes in this time table.
Refer Station Basic Feature Template to assign time table to station.
Refer Trunk Feature Template to assign time table to trunk.
It is also possible to set the time zone for the stations and trunks
manually, refer System Manual for more details.

10. Program flexible numbers

By default, stations are assigned flexible numbers as given below:

SLT : 2001 to 2512

DKP : 3001 to 3128

ISDN Terminal : 3201 to 3264


Refer SLT Parameters to change the flexible numbers of SLTs.
Refer DKP Parameters to change the flexible numbers of DKPs.
Refer ISDN Terminal Parameters to change the flexible numbers of
ISDN terminals.

11. DSS Console

Each Digital Key Phone can be assigned maximum 2 DSS Consoles


Refer, "DKP Parameters", to assign DSS console to DKP.
Hardware Slot - Port, to which DSS is connected, shall be assigned to
the desired DKP port as "DSS 1 H/w Slot - Port".
To attach second DSS console to same DKP Port, assign hardware
slot - port of other DSS console to the DKP port as "DSS 1 H/w Slot Port" parameters.

Example:
DKP Card is installed in slot 05.
Digital Key Phones are connected on 1st and 2nd port of the DKP Card.
One DSS is connected to 3rd port of DKP Card.
Second DSS is connected on 4th port of the DKP Card.

To assign one DSS to each DKP port following programming shall be


done in "DKP Parameters".

To assign both DSS to DKP -001 following programming shall be


done in "DKP Parameters".

12. CLIP

CLI detection on TRK


By default for region code India, all TRK ports are configured to
etect the DTMF CLI, refer TWT Hardware Template-Rx CLI Type.
Know the CLI type supported by exchange and configure this
parameter accordingly.

CLI presentation on SLT


In default settings for India and other regions except United
States, Mexico, Namibia and Canada, all SLT ports are assigned
SLT Hardware Template -01.

By default, CLIP Type is set as DTMF, in SLT Hardware


Template - 01.

Refer, SLT Hardware Template (01) - CLIP Type, to change


it if required.
In default settings for regions United States, Canada, Mexico and
Namibia all SLT ports are assigned SLT Hardware Template-06.

By default, CLIP Type is set as FSK Bellcore, in SLT


Hardware Template - 06.

Refer, SLT Hardware Template (06) - CLIP Type, to change it


as required.
Know the CLIP protocol supported by the telephone instrument to
be connected on SLT Port and configure this parameter
accordingly.
You may assign different SLT Hardware Template to different SLT
Ports if required. Refer, SLT Parameters to assign SLT
Hardware Template to SLT.

No configuration is required for CLI detection on Mobile, DS1, BRI and


SIP Trunks.
No configuration is required for presenting the CLI on DKP and ISDN
Terminals.

13. Class of Service

Class of Service is part of Station Basic Feature Template, by default


all the stations are assigned Station Basic Feature Template-01, in
which COS group 03 is assigned for working hour, break hours and
non-working hours.
Refer Class of Service to check the default settings of the CoS
group 03 and customise CoS group as required.
Refer Station Basic Feature Template to change the default CoS
group assigned to the station
Station can be assigned different COS group by assigning different
Station Basic Feature Templates.
Refer SLT Parameters to change Station Basic Feature Template
assigned to SLT Ports. Refer, DKP Parameters to change Station
Basic Feature Template assigned to DKP Ports. Refer ISDN
Terminal Parameters to change Station Basic Feature Templates
assigned to ISDN Terminals.

14. Toll Control

Toll control is part of Station Basic Feature Template, by default all the
stations are assigned Station Basic Feature Template - 01.
By default, all the stations are assigned Allowed List - 03 and Denied
List - 03 for working hour, break hours and non-working hours.
By default, all the stations are allowed to make Local, STD and ISD
calls.
Refer External Number List to customise allowed and denied number
Lists as required.
Refer Station Basic Feature Template assigned to the station to
change number list assigned in default settings.

15. Trunk Access

Trunk Access is part of Station Basic Feature Template, by default all


the stations are assigned Station Basic Feature Template - 01.
By default all stations are assigned OG Trunk Bundle Group = 01.
By default members of the OG Trunk Bundle Group-01 are none,
means in default configuration the stations are not given access to
any trunks.
Refer OG Trunk Bundle to form the OG Trunk Bundles as desired.
Refer OG Trunk Bundle Group, program the OG Trunk Bundles as
members of the OG Trunk Bundle Group.
Refer Station Basic Feature Template assigned to the station, to
assign different OG Trunk Bundle Group for different Trunk Access
Codes.

16. LCR

By default, LCR is disabled on all the OG Trunk Bundle Groups.


Refer OG Trunk Bundle Group - LCR Type, to enable the required
LCR type.
Refer links of Least Cost Routing to program attributes of the LCR.

17. Trunk Landing

Routing the incoming call to Trunk Landing Group


By default all the trunks are assigned trunk landing group (routing
group) 01.
By default members of the routing group 01, are DKP 001 to 008
and SLT 001 to 008.
Refer Routing Groups to program the routing groups with
desired members.
Refer Trunk Feature Template to assign the routing group to trunk
for working hours, break hours and non working hours.

DID
By default DID is disabled on all the trunks for working hours,
break hours and non working hours.
Refer Trunk Feature Template to enable DID for the working
hours, break hours and non working hours as desired.
Refer Voice Message Applications to assign voice modules for
the different messages of the DID.

CLI Based Routing


By default all the entries of the CLI Based Routing Table are
blank.
Refer CLI Based Routing to program the desired destination for
particular calling number.

DDI (Direct Dialing In)


Refer DS1 Port Parameter, to assign IC Reference ID and OG
Reference ID to DS1 Port for working hours, break hours and non
working hours.
Refer links of the DDI Routing, viz. IC Reference Table, DDI
Routing Table and Outgoing Reference Table to program DDI
Routing.
For more details refer System Manual.

Trunk Auto Answer


By default Trunk Auto Answer is disabled on all the trunks for
working hours, break hours and non-working hours.
Refer Trunk Feature Template to enable Trunk Auto Answer for

the working hours, break hours and non-working hours as


desired.
Refer Voice Message Applications to assign voice modules for
the Auto Answer Greeting message, Auto Answer RBT message
and Auto Answer Bye message.

DISA
By default DISA is disabled on all the trunks for working hours,
break hours and non-working hours.
Refer Trunk Feature Template to enable DISA for the working
hours, break hours and non-working hours as desired.

Refer system manual chapter Incoming Call Management for more


details and interactions of DID, DISA, Trunk Auto Answer, DDI and CLI
Based Routing.

18. Program the Operator Group

By default, all the stations and trunks are assigned operator-1.


By default routing group number 32 is programmed as operator-1 for
working hours, break hours and non-working hours.
By default, members of the Routing Group 32 are DKP001 to 008 and
SLT 001 to 008.
Made list of operator station for working hours, break hours and non
working hours.
Refer Routing Group to form routing groups with members which are
to be used as operator for working hours, break hours and non
working hours.
Refer Operators to assign the routing group as operators.
Refer Station Basic Feature Template to assign operator to the
station.
Refer Trunk Feature Template to assign operator for the trunk.

19. DS1 Port

By default, the orientation type of the DS1 port is Terminal.


To connect the DS1 port with the Public network, orientation type of
the DS1 port shall be Terminal (TE).
To connect the DS1 port for private networking, the orientation type
shall be set to Terminal/Network depending on the network scenario.
Refer DS1 Port Parameters to configure the basic attributes of the
DS1 port.
By default, the DS1 port is set to support E1 PRI signaling. Refer
DS1 Port Parameters - Signal Type to change the signaling as T1
PRI/E1 CAS/T1 RBS as supported by the exchange (Network).

E1 PRI Signaling
Know the PRI switch variant supported by exchange.
In case of private networking set the ISDN switch variant
supported by both the PBXs.
By default, the PRI Switch variant is ETSI NET5.
Refer PRI Parameters, to change the attributes of the PRI
signaling.

E1 CAS Signaling
To set E1 CAS signaling on DS1 port, go to DS1 Port Parameter
- Signal Type, configure it as E1 CAS.
By default the E1 Line Signaling Variant is ITU T Q.400 Q.490
and E1 Registered Signaling variant is MFC R2.
Know the Line Signaling and Registered Signaling variant
supported by the exchange, while in case of private networking
use the signaling variant supported by both the PBXs.
Refer E1 CAS Parameters, to change the attributes of the E1
CAS signaling.

T1 RBS Signaling
To set T1 RBS signaling on DS1 port, go to DS1 Port Parameter
- Signal Type, configure it as T1 RBS.
By default the T1 Line Signaling Variant is E&M Wink Start FGD
and Registered Signaling variant is DTMF.
Know the T1 Line Signaling and Registered Signaling variant
supported by the exchange, while in case of private networking
set the signaling variant supported by both the PBXs.
Refer T1 RBS Parameters, to change the attributes of the T1
RBS signaling.

Each DS1 Port is assigned following templates in default


configuration:

Trunk Feature Template Number 01


Station Basic Feature Template Number 01
Station Advance Feature Template Number 01

The assigned templates can be changed or customised as required.

When DS1 port orientation type is Terminal, the Trunk Feature Template
assigned to it is of relevance.
When DS1 port orientation type is Network, the Station Basic Feature
Template and Station Advance Feature Template assigned to it are of
relevance.

20. Mobile Port

SIM Card subscribed from the GSM Service Provider can be installed
in the GSM Mobile Port.
RUIM subscribed from the CDMA service provider can be installed in
the CDMA Mobile port.
Make sure that you are installing the Eternity where sufficient network
coverage is available.

Band Selection:
Select the Frequency Band which is used by your Service
Provider. In default configuration Mobile Port is set to operate at
900+1800 MHz. Refer parameter Band Selection in Mobile Port
Parameters to change the Band for the Mobile Port.

Network Selection:
Important Points:
In GSM you can select and use network selection as 'Automatic'/
'Manual' as desired.
In CDMA, manual network selection is not supported; hence in
CDMA it is must to use Automatic network selection.
Refer Mobile Network Selection for configuring the Network
related attributes.

By default, all Mobile ports are configured to select the


network automatically. The Network Selection Mode is
Automatic.

If the network is to be selected manually, set the Network


Selection Mode as Manual. Program the Network Operator
code (MCC-MNC) in priorities for the Mobile Port.

Refer Mobile Port Parameters and Mobile Network Selection for


configuring the Mobile Ports attributes.
By default Mobile ports are assigned Trunk Feature Template number
01.

21. BRI Port

By default, the orientation type of the BRI port is Terminal.


To connect the BRI port with public network, orientation type of the
BRI port shall be Terminal.
By default, the BRI Switch variant for the BRI port is ETSI NET 3.
Know the BRI switch variant supported by public network. Refer BRI
Parameters, to change the attributes of the BRI Port.
To connect the BRI port for private networking, orientation type can
be set as Network/Terminal depending on the private network

scenario. Select the BRI Switch Variant which is supported by both


the PBXs.
To connect the ISDN Terminals with the BRI Port, orientation type of
BRI port shall be set as Network. Check the BRI Switch Variant
supported by the BRI port and the ISDN terminals; choose the
common switch variants supported by them.
Each BRI Port is assigned following templates in default
configuration:
Trunk Feature Template-01
Station Basic Feature Template -01
Station Advance Feature Template -01
The assigned templates can be changed or customised as required.

When BRI port is configured as Terminal, the Trunk Feature Template


assigned to it is of relevance.
When BRI port is configured as Network, the Station Basic Feature
Template and Station Advance Feature Template assigned to it is of
relevance.
Refer ISDN Terminal Parameters for configuration of ISDN Terminal
interfaced with the BRI Port.

22. E&M Trunk

By default, E&M Port is assigned following templates in default


configuration.
E&M Feature Template - 01
Trunk Feature Template - 01
Station Basic Feature Template - 01
Station Advance Feature Template - 01
Refer, E&M Parameters, to assign different template to the E&M
Port.
By default Seizure Type for the E&M port is Immediate, refer E&M
Feature Template to change the Seizure Type as required.
By default Release Type for the E&M port is Status Change, refer
E&M Feature Template to change the Release Type as required.
By default Orientation Type for the E&M port is Station, refer E&M
Feature Template to change the Orientation Type as required.
By default the Dial Type for the E&M port is Pulse, with Pulse Dial
Ratio 10PPS 1:2, refer E&M Feature Template to change the Dial
Type to Tone if required.

Station Advance Feature Template and Station Basic Feature Template is


of significance when E&M Port orientation type is Station.

Trunk Feature Template is of significance when E&M Port orientation type


is Trunk.

23. VoIP Ethernet Port


To make VoIP calls you must have,

Broadband Internet Connection to make/receive calls through Public


Internet. If you wish to make calls within your network, you do not
need an Internet connection.
A SIP Account with an Internet Telephony Service Provider (ITSP). If
you want to make peer-to-peer calls (i.e. calls made without
intervention of SIP Server or Proxy Server) you do not need the
service of ITSP.

Configuring the VoIP Ethernet Port

To configure VoIP Ethernet Port, refer VoIP Ethernet Port


Parameters.
Know the Connection Type of the LAN from Administrator and
configure the Connection Type for the VoIP Ethernet Port
accordingly.
If Connection Type = Static

The default connection type is set as Static for all the VoIP
Ethernet Ports.

Default IP Address of the VoIP Ethernet Port is


192.168.1.116, and Network Mask is 255.255.255.0, change
the IP address and Network Mask as per your LAN
Addressing scheme.

Program the Routers LAN interface IP Address as a


Gateway IP Address for the VoIP Ethernet Port.

Program the DNS Address/Domain Name as provided by


your Internet Service Provider.

If Connection Type = DHCP

Change the Connection Type to DHCP.

The VoIP Ethernet Port IP Address, Network Mask and


Gateway Address will be provided by dynamically by the
DHCP server on LAN. You have to set the DNS address only.

If DHCP server provides DNS address, set the DNS


Connection Type to Auto

If DHCP server does not provide DNS address, program the


DNS server address/DNS Name as provided by your Internet
Service Provider.

If Connection Type = PPPoE

Change the Connection Type to PPPoE.

The PPPoE server will automatically assign the VoIP


Ethernet Port IP Address, Network Mask and Gateway
Address.

Program the PPPoE User name and Password as provided


by the Internet Service Provider.

If PPPoE server doesnt provide the DNS address, program


the DNS Address/DNS Name as provided by your Internet
Service Provider.

If DNS address is provided by the PPPoE server, set the


DNS Connection Type to Auto.

24. SIP Trunk

To configure SIP Trunk refer, SIP Trunk Parameters


Configure Proxy SIP Trunk as shown below:

Assign the VoIP Port to be used for the SIP Trunk.

Enable the SIP Trunk.

Program the SIP ID, Registrar Server Address, Registrar


Server Port, Authentication ID, Authentication Password as
provided by your ITSP.

If your ITSP uses Outbound Proxy, Enable the Outbound


Proxy for the SIP Trunk and also program the Outbound
Proxy Server Address and Port as provided by your ITSP.

25. VMS Card

The Eternity automatically assigns un-used SLT software ports (i.e.


SLT ports which are not assigned any hardware slot-port) as VMS
port.
The SLT software ports used by VMS card are automatically gets
configured in Routing Group number 33.
The Eternity automatically assigns Routing Group number 33 as VMS
Group.
Default access code of VMS group is 3931, refer Access Codes VMS Group, to change default access code.
To land incoming calls at VMS, program Routing Group 33 as TLG in
the trunk feature template assigned to the respective trunk.
By default there is no Message Wait Notification for all stations.
Message wait notification is part of Station Advance Feature template,
hence refer Station Advance Feature Template assigned to the station
to set Message Wait Notification Type as required.
VMS is also referred as CadencePro in Eternity.

Configuring the VMS Card


Collect following information:

Decide to which extension numbers, mailbox has to be assigned.

If Ethernet port of CadencePro is going to be connected in the


network, consult LAN administrator and get the IP Address and
Subnet mask to be assigned to the Candencepro.
How to reach the Home Page of Web Server of VMS?

Connecting the VMS card with the computer

Connect the Ethernet Port of the VMS Card to the Ethernet Port of
the Computer using the RJ-45 cable provided with the card.
The default IP Address of the VMS card is 192.168.1.131 and Subnet
Mask is 255.255.255.0.
To access the web server of VMS card using computer, the VMS
Ethernet port and computer shall be in the same subnet.
Follow below given steps to change the VMS Ethernet port IP
Address and Subnet Mask:
Step 1: Entering into the Programming mode

Dial VMS Group access code (Default 3931) from any station
VMS will answer the call and greet with Welcome Message.
Dial *19-1234 (1234 is the default SE Password of VMS) during
the Welcome message.
VMS will greet with Enter the Programming Command.

Step 2: Assigning an IP Address

Enter into the programming mode by following the step 1 i.e.


Entering into the Programming mode.
Dial the SE command 1501-IP Address-#*.
For example, if the IP address 192.168.1.182 is to be
programmed, the SE command shall be given as,
1501-192168001182-#*.
VMS card will restart once you enter this command.

Step 3: Assigning an Subnet Mask

Enter into the programming mode by following the step 1. i.e


Entering into the Programming mode.
Dial the SE command 1502-Subnet Mask-#*.
For example, if the subnet mask 255.255.255.0 is to be
programmed, the SE command shall be given as, 1502-

255255255000-#*.
VMS will restart once you enter this command.

You may also connect the VMS card port in LAN of the organization. But
make sure that the VMS card and the computer you are using to access it
are in the same subnet.
Configuring the VMS using the Web Interface
Access the Webjeeves of the CadencePro

Open the Web browser/Internet Explorer.

Enter the IP address of the CadencePro Network Port in the URL field of
the Web browser/Internet Explorer and press Enter key.

The CadencePro will prompt for login as shown below:

You can enter the User name of your choice. (Entering the user name is
not mandatory for login.)
Enter the SE Password (default: 1234) in the Password field.
Click on the Login button.
On successful login, you will be taken to the Home Page.

Now, you can configure the CadencePro using Web Jeeves.


The left most side displays the link for different web pages for configuring.
Click on the link and the respective webpage will get opened.
Make required changes and click on Submit button given on the bottom
of the webpage to affect the changes.

Configuring the Region Code:

By default, Region Code = India.


To change the Region code, click on the link System Parameters and
refer Region Code options.
Select the Region code from the list and Submit the page.
Following parameters would be changed as per the Region code
programmed:

Operator code for Home Node

DST type

Welcome Messages for Port

Configuring the Date & Time Settings:

Click on the link Date & Time Settings and Date & Time Settings
webpage will open as given below:

Current Date & Time:

Program the Current Date and Current Time.

Current date & time is required in the system because certain


features like Time table, holidays, Greetings, etc. relates to date & time.
Time Table:

Program the start time and end time of working hours for weekdays in the
Time Table. Remaining time would be considered as Non-working hours.

Welcome messages are played according to the time table programmed.


For example:
For Monday, Start time is programmed as 09:00 and End time is
programmed as 18:00 for working hours.
Thus, 00:00 to 08:59 and 18:00 to 23:59 would be considered as Nonworking hours.
Holidays:

Program the date and month of holidays.

On holidays, time table would not be applicable and Welcome message is


played according to the holidays.
Configuring the Station Parameters:

Click on the link Station Parameters and Station Parameters webpage


will open as given below:

Extension Number:
Program the Extension numbers of the PBX which are to be
allowed.

Mailbox Number:
By default, no Mailbox is assigned to any Station number.
Assign the Mailbox number (001-512) to the Station Number if
mailbox facility is to be given. Use 000 for not assigning a
mailbox number.
Same mailbox number should not be assigned to two different
station numbers.
For changing the Mailbox related parameters, refer topic
Configuring the Mailbox Parameters.

Abbreviated Name:
By default, blank for all station number.
Assign abbreviated name if dial by name feature is to be used
Only 3 alphabets of the station user name can be programmed in
Abbreviated name and it should be enter in capital letters i.e for
example: program RAK for Rakesh.

Mode:
Mode for each station is used for transfer type.
Different Modes supported are Manual and Scheduled.
Program Manual mode for Station if Transfer type is to be kept
fixed through out the day.
Program Scheduled mode for Station if Transfer type is to be kept
different at different time of the day.
By default, Mode = Manual.

If Manual Mode is programmed:


Program the Transfer type in the field Manual Mode Transfer
Type for the station.
By default, Manual Mode Transfer Type = Wait for Answer.
For different transfer types refer Transfer Types.

If Scheduled Mode is programmed:


Program Start Time and Transfer Type for Time Zone 1 - Time
Zone 4 in Scheduled Mode.
Start Time for Time Zone 1-Time Zone 4:

By default, Start Time = 00.00.

Start time of Time Zone 2 is the End time of Time Zone 1 and
so on. Thus, program the Start time accordingly.
Transfer Type for Time Zone 1-Time Zone 4:

By default, Transfer Type = Wait for Answer

For different transfer types refer Transfer Types.

Transfer Types:
Different transfer type which can be set is as given below:
None - Directly transfers the caller to the mailbox if assigned.
Blind - Directly transfers the caller to the extension number
dialed by the caller without knowing the status of the extension i.e
whether it is busy or not.
Wait for Ring - Transfers the caller to the extension number
dialed by the caller if the extension is ringing i.e ring is detected
by the CadencePro.
Wait for Answer - Transfers the caller to the extension number
dialed by the caller only if it is answered.
Screen - CadencePro asks the caller to record its name and the
recorded name is played to the extension number dialed by the
caller if it answers. If extension user accepts the call it is
transferred otherwise takes the caller to the home node.

Configuring the Mailbox Parameters:

Click on the link Mailbox Parameters and Mailbox Parameters webpage


will open as given below:

Mailbox Size:
Default Mailbox size = 5 minutes for each mailbox. Maximum size
of mailbox can be of 999 minutes for each mailbox.
Change the Mailbox size for mailbox depending upon who is the
Station user.

Maximum Message Length:


Default Maximum Message Length = 15 seconds for each
mailbox. Maximum message length can be of 999 seconds.
Change the Message length of the mailbox depending upon who
is the Station user.

Ask Mailbox Password at Login:


Default = Yes.
You can also programmed it as No i.e password will not be
asked from the station user while accessing the mailbox.

Message Notification:
Default = No.
Program it as Yes for the mailbox depending upon the station
user.

Checking the VMS installation

Dial the VMS group number (default 3931) form station. The call shall be
automatically answered by the VMS and you shall hear the voice
message programmed in the VMS.

26. Disconnect tone Detection

If you are using TRK and using DID (Auto Attendant) on the same,
enable Disconnect Tone Detection and program Disconnect Tone
Cadence in TWT hardware Template assigned to TRK.
For more detail refer, Eternity System manual - Disconnect Tone
Detection.

27. Change the SE password

Once you finish installation, you are advised to change the SE


password to prevent unauthorised access.
Refer Change Password to change the SE password.

Appendix
Cable Diagram for cards of Eternity-ME
SLT08
Port
SLT01
SLT02
SLT03
SLT04
SLT05
SLT06
SLT07
SLT08

Color
Blue-White
Orange-White
Green-White
Brown-White
Grey-White
Blue-Red
Orange-Red
Green-Red

SLT16
Port
SLT01
SLT02
SLT03
SLT04
SLT05
SLT06
SLT07
SLT08
SLT09
SLT10
SLT11
SLT12
SLT13
SLT14
SLT15
SLT16

Color
Blue-White
Orange-White
Green-White
Brown-White
Grey-White
Blue-Red
Orange-Red
Green-Red
Brown-Red
Grey-Red
Blue-Black
Orange-Black
Green-Black
Brown-Black
Grey-Black
Blue-Yellow

TWT08
(Lower MDF Connector)
Port
Color
TWT01 Grey-Black
TWT02 Blue-Yellow
TWT03 Orange-Yellow
TWT04 Green-Yellow

SLT32
(Lower MDF Connector)
Port
Color
SLT01
Blue-White
SLT02
Orange-White
SLT03
Green-White
SLT04
Brown-White
SLT05
Grey-White
SLT06
Blue-Red
SLT07
Orange-Red
SLT08
Green-Red
SLT09
Brown-Red
SLT10
Grey-Red
SLT11
Blue-Black
SLT12
Orange-Black
SLT13
Green-Black
SLT14
Brown-Black
SLT15
Grey-Black
SLT16
Blue-Yellow

TWT08
(Upper MDF Connector)
Port
Color
TWT05 Grey-Black
TWT06 Blue-Yellow
TWT07 Orange-Yellow
TWT08 Green-Yellow

SLT32
(Upper MDF Connector)
PORT
COLOR
SLT17 Blue-White
SLT18 Orange-White
SLT19 Green-White
SLT20 Brown-White
SLT21 Grey-White
SLT22 Blue-Red
SLT23 Orange-Red
SLT24 Green-Red
SLT25 Brown-Red
SLT26 Grey-Red
SLT27 Blue-Black
SLT28 Orange-Black
SLT29 Green-Black
SLT30 Brown-Black
SLT31 Grey-Black
SLT32 Blue-Yellow

TWT04+SLT12
Por t

Color

SLT01

Blue-White

SLT02

Orange-White

SLT03

Green-White

SLT04

Brow n-White

SLT05

Grey-White

SLT06

Blue-Red

SLT07

Orange-Red

SLT08

Green-Red

SLT09

Brow n-Red

SLT10

Grey-Red

SLT11

Blue-Black

SLT12

Orange-Black

TWT01

Green-Black

TWT02

Brow n-Black

TWT03

Grey-Black

TWT04

Blue-Y ellow

TWT08+SLT24
(Lower MDF Connector)
Port
Color

TWT08+SLT24
(Upper MDF Connector)
PORT
COLOR

SLT01

Blue-White

SLT13

SLT02

Orange-White

SLT14

Orange-White

SLT03

Green-White

SLT15

Green-White

SLT04

Brown-White

SLT16

Brown-White

SLT05

Grey-White

SLT17

Grey-White

SLT06

Blue-Red

SLT18

Blue-Red

SLT07

Orange-Red

SLT19

Orange-Red

SLT08

Green-Red

SLT20

Green-Red

SLT09

Brown-Red

SLT21

Brown-Red

SLT10

Grey-Red

SLT22

Grey-Red

SLT11

Blue-Black

SLT23

Blue-Black

SLT12

Orange-Black

SLT24

Orange-Black

TWT01

Green-Black

TWT05

Green-Black

TWT02

Brown-Black

TWT06

Brown-Black

TWT03

Grey-Black

TWT07

Grey-Black

TWT04

Blue-Yellow

TWT08

Blue-Yellow

Blue-White

DLC08/DLC16 CARD
Port
Color
DKP01

Blue-White

DKP02

Orange-White

DKP03

Green-White

DKP04

Brown-White

DKP05

Grey-White

DKP06

Blue-Red

DKP07

Orange-Red

DKP08

Green-Red

DKP09

Brown-Red

DKP10

Grey-Red

DKP11

Blue-Black

DKP12

Orange-Black

DKP13

Green-Black

DKP14

Brown-Black

DKP15

Grey-Black

DKP16

Blue-Yellow

Port

E&M04 CARD
Color

E&M01-M, SB

Blue-White

E&M01-E, SG

Orange-White

E&M01-SP(RxA), SP(RxB)

Green-White

E&M01-SP(A), SP(B)

Brown-White

E&M01-02 CCS

Grey-White

E&M02-M, SB

Blue-Red

E&M02-E, SG

Orange-Red

E&M02-SP(RxA), SP(RxB)

Green-Red

E&M02-SP(A), SP(B)

Brown-Red

E&M03-M, SB

Grey-Red

E&M03-E, SG

Blue-Black

E&M03-SP(RxA), SP(RxB)

Orange-Black

E&M03-04 CCS

Green-Black

E&M04-M, SB

Brown-Black

E&M04-E, SG

Grey-Black

E&M04-SP(RxA), SP(RxB)

Blue-Yellow

E&M04-SP(A), SP(B)

Orange-Yellow

E&M08 CARD
(Lower MDF Connector)
Port
Color
E&M01-M, SB
Blue-White
E&M01-E, SG
Orange-White
E&M01-SP(RxA), SP(RxB)
Green-White
E&M01-SP(A), SP(B)
Brown-White
E&M01-02 CCS
Grey-White
E&M02-M, SB
Blue-Red
E&M02-E, SG
Orange-Red
E&M02-SP(RxA), SP(RxB)
Green-Red
E&M02-SP(A), SP(B)
Brown-Red
E&M03-M, SB
Grey-Red
E&M03-E, SG
Blue-Black
E&M03-SP(RxA), SP(RxB)
Orange-Black
E&M03-04 CCS
Green-Black
E&M04-M, SB
Brown-Black
E&M04-E, SG
Grey-Black
E&M04-SP(RxA), SP(RxB)
Blue-Yellow
E&M04-SP(A), SP(B)
Orange-Yellow

E&M08 CARD
(Upper MDF Connector)
Port
Color
E&M05-M, SB
Blue-White
E&M05-E, SG
Orange-White
E&M05-SP(RxA), SP(RxB)
Green-White
E&M05-SP(A), SP(B)
Brown-White
E&M05-06 CCS
Grey-White
E&M06-M, SB
Blue-Red
E&M06-E, SG
Orange-Red
E&M06-SP(RxA), SP(RxB)
Green-Red
E&M06-SP(A), SP(B)
Brown-Red
E&M07-M, SB
Grey-Red
E&M07-E, SG
Blue-Black
E&M07-SP(RxA), SP(RxB)
Orange-Black
E&M07-08 CCS
Green-Black
E&M08-M, SB
Brown-Black
E&M08-E, SG
Grey-Black
E&M08-SP(RxA), SP(RxB)
Blue-Yellow
E&M08-SP(A), SP(B)
Orange-Yellow

BRI04/BRI08 CARD
(Lower MDF Connector)
Port
Port

BRI04/BRI08 CARD
(Lower MDF Connector)
Port
Color

BRI01 TxA, TxB Blue-White


BRI01 RxA, RxB Orange-White
BRI01 V-, V+
Green-White

BRI05 TxA, TxB Blue-White


BRI05 RxA, RxB Orange-White
BRI05 V-, V+
Green-White

BRI02 TxA, TxB Brown-White


BRI02 RxA, RxB Grey-White
BRI02 V-, V+
Blue-Red

BRI06 TxA, TxB Brown-White


BRI06 RxA, RxB Grey-White
BRI06 V-, V+
Blue-Red

BRI03 TxA, TxB Orange-Red


BRI03 RxA, RxB Green-Red
BRI03 V-, V+
Brown-Red

BRI07 TxA, TxB Orange-Red


BRI07 RxA, RxB Green-Red
BRI07 V-, V+
Brown-Red

BRI04 TxA, TxB Grey-Red


BRI04 RxA, RxB Blue-Black
BRI04 V-, V+
Orange-Black

BRI08 TxA, TxB Grey-Red


BRI08 RxA, RxB Blue-Black
BRI08 V-, V+
Orange-Black

Cable Diagram for cards of Eternity-GE

Port

SLT08
Color

Port

SLT16
Color

SLT01

Blue-White

SLT01

SLT02

Orange-White

SLT02

Orange-White

SLT03

Green-White

SLT03

Green-White

SLT04

Brown-White

SLT04

Brown-White

SLT05

Grey-White

SLT05

Grey-White

SLT06

Blue-Red

SLT06

Blue-Red

SLT07

Orange-Red

SLT07

Orange-Red

SLT08

Green-Red

SLT08

Green-Red

SLT09

Brown-Red

Port

TWT02 + SLT14
Color

Blue-White

SLT10

Grey-Red

SLT11

Blue-Black

SLT12

Orange-Black

SLT13

Green-Black

SLT14

Brown-Black

SLT15

Grey-Black

SLT16

Blue-Yellow

Port

TWT04+SLT04
Color

TWT01 Blue-White

SLT01

Blue-White

TWT02 Orange-White

SLT02

Orange-White

NC

Green-White

SLT03

Green-White

NC

Brown-White

SLT04

Brown-White

SLT01

Grey-White

NC

Grey-White

SLT02

Blue-Red

NC

Blue-Red

SLT03

Orange-Red

TWT01

Orange-Red

SLT04

Green-Red

TWT02

Green-Red

SLT05

Brown-Red

TWT03

Brown-Red

SLT06

Grey-Red

TWT04

Grey-Red

SLT07

Blue-Black

NC

Blue-Black

SLT08

Orange-Black

NC

Orange-Black

SLT09

Green-Black

SLT10

Brown-Black

SLT11

Grey-Black

SLT12

Blue-Yellow

SLT13

Orange-Yellow

SLT14

Green-Yellow

DLC04 / DLC08 CARD


Port
Color
DKP01

Blue-White

DKP02

Orange-White

DKP03

Green-White

DKP04

Brown-White

DKP05

Grey-White

DKP06

Blue-Red

DKP07

Orange-Red

DKP08

Green-Red
DLC02+SLT06

Port

DLC04+SLT12
Color

SLT01

Blue-White

SLT02

Orange-White

SLT03

Green-White

SLT04

Brown-White

SLT05

Grey-White

SLT06

Blue-Red

SLT07

Orange-Red

SLT08

Green-Red

SLT09

Brown-Red

SLT10

Grey-Red

SLT11

Blue-Black

SLT12

Orange-Black

DKP01

Green-Black

DKP02

Brown-Black

DKP03

Grey-Black

DKP04

Blue-Yellow

Port

E&M02/E&M04 CARD
Color

E&M01-M, SB

Blue-White

E&M01-E, SG

Orange-White

E&M01-SP(RxA), SP(RxB)

Green-White

E&M01-SP(A), SP(B)

Brown-White

E&M01-02 CCS

Grey-White

E&M02-M, SB

Blue-Red

E&M02-E, SG

Orange-Red

E&M02-SP(RxA), SP(RxB)

Green-Red

E&M02-SP(A), SP(B)

Brown-Red

E&M03-M, SB

Grey-Red

E&M03-E, SG

Blue-Black

E&M03-SP(RxA), SP(RxB)

Orange-Black

E&M03-04 CCS

Green-Black

E&M04-M, SB

Brown-Black

E&M04-E, SG

Grey-Black

E&M04-SP(RxA), SP(RxB)

Blue-Yellow

E&M04-SP(A), SP(B)

Orange-Yellow

SLT16 Card
Connector

Port

Colour

RJ45-1
(Blue)

SLT 01
SLT 02
SLT 03
SLT 04

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-2
(Orange)

SLT 05
SLT 06
SLT 07
SLT 08

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-3
(Green)

SLT 09
SLT 10
SLT 11
SLT 12

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-4
(Brown)

SLT 13
SLT 14
SLT 15
SLT 16

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

L1 L2

TRK16 Card
Connector

Port

Colour

RJ45-1
(Blue)

TRK 01
TRK 02
TRK 03
TRK 04

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-2
(Orange)

TRK 05
TRK 06
TRK 07
TRK 08

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-3
(Green)

TRK 09
TRK 10
TRK 11
TRK 12

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-4
(Brown)

TRK 13
TRK 14
TRK 15
TRK 16

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

L1 L2

TWT8 Card
L1 L2

Connector

Port

Colour

RJ45-1

TWT 01
TWT 02
TWT 03
TWT 04

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-2

TWT 05
TWT 06
TWT 07
TWT 08

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-3

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-4

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

DKP16 Card
Connector

Port

Colour

RJ45-1
(Blue)

DKP 01
DKP 02
DKP 03
DKP 04

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-2
(Orange)

DKP 05
DKP 06
DKP 07
DKP 08

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-3
(Green)

DKP 09
DKP 10
DKP 11
DKP 12

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-4
(Brown)

DKP 13
DKP 14
DKP 15
DKP 16

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

L1 L2

TRK2, DKP2, SLT16 Card


L1 L2

Connector

Port

Colour

RJ45-1
(Blue)

SLT 01
SLT 02
SLT 03
SLT 04

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-2
(Orange)

SLT 05
SLT 06
SLT 07
SLT 08

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-3
(Green)

SLT 09
SLT 10
SLT 11
SLT 12

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-4
(Brown)

SLT 13
SLT 14
SLT 15
SLT 16

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-5
(Gray)

DKP 01
DKP 02

Blue - (Blue & White)


Orange - (Orange & White)

RJ45-6
(Red)

TRK 01
TRK 02

Blue - (Blue & White)


Orange - (Orange & White)

TRK4, SLT16 Card


L1 L2

Connector

Port

Colour

RJ45-1
(Blue)

SLT 01
SLT 02
SLT 03
SLT 04

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-2
(Orange)

SLT 05
SLT 06
SLT 07
SLT 08

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-3
(Green)

SLT 09
SLT 10
SLT 11
SLT 12

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-4
(Brown)

SLT 13
SLT 14
SLT 15
SLT 16

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-5
(Gray)

TRK 01
TRK 02

Blue - (Blue & White)


Orange - (Orange & White)

RJ45-6
(Red)

TRK 03
TRK 04

Blue - (Blue & White)


Orange - (Orange & White)

DKP4, SLT16 Card


L1 L2

Connector

Port

Colour

RJ45-1
(Blue)

SLT 01
SLT 02
SLT 03
SLT 04

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-2
(Orange)

SLT 05
SLT 06
SLT 07
SLT 08

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-3
(Green)

SLT 09
SLT 10
SLT 11
SLT 12

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-4
(Brown)

SLT 13
SLT 14
SLT 15
SLT 16

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-5
(Gray)

DKP 01
DKP 02

Blue - (Blue & White)


Orange - (Orange & White)

RJ45-6
(Red)

DKP 03
DKP 04

Blue - (Blue & White)


Orange - (Orange & White)

SLT20 Card
L1 L2

Connector

Port

Colour

RJ45-1

SLT 01
SLT 02
SLT 03
SLT 04

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-2

SLT 05
SLT 06
SLT 07
SLT 08

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-3

SLT 09
SLT 10
SLT 11
SLT 12

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-4

SLT 13
SLT 14
SLT 15
SLT 16

Blue - (Blue & White)


Orange - (Orange & White)
Green - (Green & White)
Brown - (Brown & White)

RJ45-5

SLT 17
SLT 18

Blue - (Blue & White)


Orange - (Orange & White)

RJ45-6

SLT 19
SLT 20

Blue - (Blue & White)


Orange - (Orange & White)

Following are the connection details of the 2-wire/4-wire, Type-4/Type-5


configuration:
2 Wire / Type 4 E&M Connection

2 Wire / Type 5 E&M Connection

SB

SB

SB

SG

SG

SG

NC

SP(RxA)

NC

SP(RxB)

SP(RxA)
SP(RxB)

NC
NC

NC

SB

SP(RxA)

NC

NC

SP(RxA)

SP(RxB)

NC

NC

SP(RxB)

NC

NC

SP(A)

SP(A)

SP(A)

SP(B)

SP(B)

SP(B)

CCS

CCS

CCS

NC

NC

One E&M Port of PBX-A

One E&M Port of PBX-B

4 Wire / Type 4 E&M Connection

M
NC

E
SG

SP(A)
SP(B)

One E&M Port of PBX-A

CCS

One E&M Port of PBX-B

4 Wire / Type 5 E&M Connection

SB

SB

SB

SG

SG

SG

SG

SP(RxA)

SP(RxA)

SP(RxA)

SP(RxA)

SP(RxB)

SP(RxB)

SP(RxB)

SP(RxB)

SP(A)
SP(B)
CCS

NC

NC

One E&M Port of PBX-A

SP(A)

SP(A)

SP(B)

SP(B)

CCS

CCS

One E&M Port of PBX-B

One E&M Port of PBX-A

CCS Connection should be made as shown below for any of the above four combination
M

NC

NC

SB

NC

NC

SB

NC

NC

SG

NC

NC

SG

SP(RxA)

NC

NC

SP(RxA)

SP(RxB)

NC

NC

SP(RxB)

SP(A)

NC

NC

SP(A)

SP(B)

NC

NC

SP(B)
CCS

CCS

One E&M Port of PBX-A

PLCC
Panel

PLCC
Panel

One E&M Port of PBX-B

M
NC

NC

SB
E

SP(A)
SP(B)
NC

NC

CCS

One E&M Port of PBX-B

MATRIX TELECOM PVT. LTD.

Factory:
39-GIDC, Waghodia - 391760, Dist. Vadodara, India.
Tel.: +91 2668 262056/57
Technical Support:
Tel.: +91 2668 263172/73, Fax: +91 2668 262631
E-mail: Support@MatrixTeleSol.com
www.MatrixTeleSol.com

Version 8, March 2009