Professional Documents
Culture Documents
Serviceable Units
All Gas Turbines with Mark VI Control Panel
Compliance Category
O Optional
Identifies changes that may be beneficial to some, but not necessarily all, operators.
Accomplishment is at customer's discretion.
M - Maintenance
C - Compliance Required
Identifies the need for action to correct a condition that, if left uncorrected, may result in
reduced equipment reliability or efficiency. Compliance may be required within a
specific operating time.
A - Alert
Failure to comply with the Service Bulletin could result in equipment or facility damage.
Compliance is mandated within a specific operating time.
S Safety
Failure to comply with this Service Bulletin could result in personal injury. Compliance is
mandated within a specific operating time.
Timing Code
1 Prior to Unit Startup / Prior to Continued Operation
2 At First Opportunity / Next shutdown
3 Prior to Operation of Affected System
4 At First Exposure of Component
5 At Scheduled Component Part Repair or Replacement
6 Next Scheduled Outage
7 Optional
Nuovo Pignone S.r.l. con socio unico (Registro Imprese di Firenze, Codice Fiscale e partita IVA 06176750484) Capitale Sociale 100.000.000,00 i.v.
Societ soggetta a direzione e coordinamento di General Electric Company
SERVICE BULLETIN
Recommendations
GE will continue to support customers operating with Mark VI systems which use the UCVx VME controller
cards in the following ways:
New Parts: The next generation VME controller card, the UCVH, is now available and can be used as an
upgrade for obsolete cards. The UCVH is available as an engineered control Modkit. In addition to the
required number of controller cards, this UCVH Modkit will include any necessary software upgrade,
engineering changes to the .M6B file and site service to implement the upgrade.
Repair Parts: GE retains the ability to test and repair the IS415UCVGH# (UCVG) through its Lifecycle
Management Services Operations, and has options to meet a variety of cycle and budgetary requirements.
Customers may elect to return a card for repair, exchange a failed board for a remanufactured board or
purchase a remanufactured card from available inventory. All of the repaired or remanufactured boards
are fully tested and include an 18-month edge-to-edge warranty. The IS215UCVBH# (UCVB) and
IS215UCVFH# (UCVF) cannot be repaired as the components required are no longer available to GE Oil &
Gas.
Note:
Modifications to the System software may be required.
Possible interdependencies with other devices on the UDH must be assessed.
Application technical assessment for a specific system can be provided by GE.
If replacement of a VME controller card is necessary, determination of the ability of the system software
(runtime and toolbox) to support the UCVH card is necessary.
The minimum eTCSS revision capable of supporting the UCVH card without a software upgrade is:
Mark VI Runtime V05.14.03C (part of eTCSS V04.08.00C released 25 January 2012
In the event of a failure involving one of these end-of-life cards, all the controllers in the system must be
replaced as a set since the UCVH controller is not compatible with the older UCVG, UCVF, UCVE, UCVD, or
UCVB controllers. A TMR system contains three controller cards, while a simplex system has one.
Finally, GE Oil & Gas suggests that customers with multiple Mark VI control systems can, if desired, continue
to use existing stocks of spare cards to maintain similar systems or use controllers removed from an
upgraded system as spares for their other systems which use the same type of controller.
2/4
Nuovo Pignone S.r.l. Proprietary Information
This Bulletin and the information contained in it are protected by copyright and/or other intellectual property rights. This Bulletin
and information are provided for authorized use only, and may not be used by or disclosed to others without the prior express written consent
of Nuovo Pignone S.r.l..
SERVICE BULLETIN
New GE Part
Number
IS415UCVGH#
IS215UCVGH#
IS215UCVFH#
IS215UCVEH#
IS215UCVDH#
IS215UCVBH#
IS215UCVFH#
IS415UCVHH#
Special Tooling
N/A
Reference Documents
GE drawing 336A7119BM
Scope of work
Customers should prepare to upgrade for UCVH controllers at their earliest convenience.
This preparation must be done while the turbine is off line and requires approximately four (4) hours per
unit. The preparation activities include changing the M6B configuration file (as per GE drawing
336A7119BM).
Note: In order to keep the GE Oil & Gas global installed fleet database updated, it is kindly requested that the
COMPLIANCE RECORD and USER SATISFACTION SURVEY be completed and sent to the addresses specified in the forms.
3/4
Nuovo Pignone S.r.l. Proprietary Information
This Bulletin and the information contained in it are protected by copyright and/or other intellectual property rights. This Bulletin
and information are provided for authorized use only, and may not be used by or disclosed to others without the prior express written consent
of Nuovo Pignone S.r.l..
SERVICE BULLETIN
4/4
Nuovo Pignone S.r.l. Proprietary Information
This Bulletin and the information contained in it are protected by copyright and/or other intellectual property rights. This Bulletin
and information are provided for authorized use only, and may not be used by or disclosed to others without the prior express written consent
of Nuovo Pignone S.r.l..
COMPLIANCE RECORD
Customer Name:
Contact Name:
Operating Hours:
Position:
No. of Starts:
e-mail:
Issue date:
Category:
Title:
YES
NO
If No, please state what was completed and what was not:
Comments:
Please complete and Fax this form to:
NOTE: The Unit Compliance Record can also be transmitted automatically by email from the My Compliance Info
GE requests that you complete this User Satisfaction Survey to help us better serve you with
accurate and timely information on your equipment
Date:
1. How many days after the Service Bulletin issue date did you receive this document?
1 - 5 days
6 - 10 days
+ 10 days
NOTE: To directly access and download GE Oil & Gas Service Bulletins published on your equipment and to
subscribe to automatic e-mail notification, please visit the Technical Updates Web Portal at:
http://www.geoilandgas.com/businesses/ge_oilandgas/en/about/technical_bulletins.htm
This online tool is available only to registered GE customers. Please refer to NIC 07.37.SL for any additional information.
Please rate the following based on a scale of 1 to 5, where 1 is Excellent and 5 is Poor.
2. How well this document informed you of the technical issue(s)
Comments or Suggestions:
Please complete and Fax this form to:
GE OIL & GAS Technical Update Communication