You are on page 1of 1

SOLAR PHOTOVOLTAIC ARRAY

GRID
INTERNET

MODEM
GATEWAY
FOR
REMOTE ACCESS

OPTIONAL
PV STRING
COMBINER
IF NEEDED

Schneider
Hybrid Inverter/Charger

EXISTING
MAIN AC
SERVICE PANEL
120/240VAC

KWH

ADARA POWER
SCHNEIDER
XW+ 5548 NA
INVERTER

INTELLIGENT LI-ION
BATTERY STORAGE SYSTEM
8.6 kWh @ 48VDC

48VDC INPUT
5500 W
120/240VAC
OUTPUT

60 A
2P

AC AC
IN OUT

SOLAR
SYSTEM
DISCONNECT
240VAC
60A
UNFUSED

GRID-TIE
INVERTER
5500W
MAX AC OUT

PROTECTED LOADS
SUB-PANEL
120/240VAC, 100A

15 A
1P

TO SITE
PROTECTED LOADS

20 A
1P

LED LIGHTING, SMALL


APPLIANCES,
MICROWAVE,
REFRIGERATOR

15 A
1P
20 A
1P

DC IN

MANUAL
BYPASS

60A
2P

60A
2P

175A

POWER
DISTRIBUTION
PANEL

30A
2P

60 A
2P

CHARGE/LOAD CONTROL FUNCTIONS VIA


ADARA-SCHNEIDER COMM LINK

NOTES:
1

MAX PV ARRAY SIZE FOR AC-COUPLED


INPUT IS 6kW, FOR LARGER SYSTEMS
ARRAY CAN BE SPLIT AND FED DIRECTLY
INTO MAIN PANEL SUBJECT TO NOTE 3
GRID-TIE INVERTER MAX AC
OUTPUT POWER NOT TO EXCEED
5500W.

NEC 705.12(D) APPLIES TO SERVICE


PANEL INTERCONNECTION

TOTAL CRITICAL LOADS SHOULD


NOT EXCEED 48A AND BE
COORDINATED WITH BATTERY
CAPACITY

FOR REFERENCE ONLY: System must be designed and installed by a licensed contractor or engineer in accordance with NEC and local building codes.