You are on page 1of 4

Instrumentation

for Industrial Process


QUIZ No.(1)
A. Multiple Choice Questions (MCQ) 10 Questions, (You can choose more
than 1 answer):
1. State down all types of final control elements from below:
o Fan
o PCV
o Heater Burner
o Photo Cell
o Heating Element
2. Valves can be categorized based on:
o Valve stem motion
o Valve Usage
o Air supply
o Valve Actuator type
o All of the above
3. Pneumatic Instruments are still mandatory for:
o No man area
o Site Legacy
o High Radiation Zone
o All of the above
4. What is most common used material for Strain Gauge:
o Platinum
o Quartz
o Silicon
o Gold
5. What are the most common techniques used for Pressure transmitters:
o Potentiometric
o Optical
o Strain Gauge
o Variable Capacitance

6. Which of the following is correct:


o C-shape bourdon pressure gauge is the best local indicator to be installed
on a gas compressor discharge with 60 bar maimum pressure
o Helical bourdon pressure gauges are perfect applicable with chemical labs
measurements
o Diaphragm sealed pressure instruments are very common with chemical and
medical industry
o All of the above
7. Which of the following is correct:
o All types of the device coupler can be installed outdoor
o Final device coupler in the segment must be terminated with a resistor
o Single device coupler can include multiple inputs and outputs.
o All of the above
8. 12 PSI pneumatic signal is representing:
o 0% of the normal pneumatic range
o 25% of the normal pneumatic range
o 50% of the normal pneumatic range
o None of the above
9. The following physical phenomena are utilized with pressure measurement
o Piezoresistive
o String natural frequency
o Buoyancy
o All of the above
10.The main parts of the Smart instruments are:
o Amplifier
o Microprocessor
o Low Pass Filter
o ADC module
o None of the above

B. True or False 10 Questions:


1. Positioner is to convert mechanical motion into electric/pneumatic signal
o True
o False
2. Span = LRV URV
o True
o False
3. Delta-V Control system can recognize and communicate with the traditional 4-20
ma Transmitter through its device manager software module
o True
o False
4. Fire resistant cable is mandatory to be used to control the Deluge Valves installed to
protect condensate storage tank
o True
o False
5. Helical bourdon pressure gauge is the best local indicator to be installed on a 700
bar well head
o True
o False
6. Wheatstone Bridge is a basic component of the pressure gauge switch
o True
o False
7. Inclined manometer is perfect to detect small pressure variation
o True
o False
8. Shield cable is to be trimmed and insulated in the instrument side
o True
o False
9. FF Positioner can host the AI & PID control block
o True
o False
10.Differential pressure with 3 - 20 PSI range can detect a differential between 1300
& 1305 PSI pressure inputs
o True
o False