QUIZ No.(1) A. Multiple Choice Questions (MCQ) 10 Questions, (You can choose more than 1 answer): 1. State down all types of final control elements from below: o Fan o PCV o Heater Burner o Photo Cell o Heating Element 2. Valves can be categorized based on: o Valve stem motion o Valve Usage o Air supply o Valve Actuator type o All of the above 3. Pneumatic Instruments are still mandatory for: o No man area o Site Legacy o High Radiation Zone o All of the above 4. What is most common used material for Strain Gauge: o Platinum o Quartz o Silicon o Gold 5. What are the most common techniques used for Pressure transmitters: o Potentiometric o Optical o Strain Gauge o Variable Capacitance
6. Which of the following is correct:
o C-shape bourdon pressure gauge is the best local indicator to be installed on a gas compressor discharge with 60 bar maimum pressure o Helical bourdon pressure gauges are perfect applicable with chemical labs measurements o Diaphragm sealed pressure instruments are very common with chemical and medical industry o All of the above 7. Which of the following is correct: o All types of the device coupler can be installed outdoor o Final device coupler in the segment must be terminated with a resistor o Single device coupler can include multiple inputs and outputs. o All of the above 8. 12 PSI pneumatic signal is representing: o 0% of the normal pneumatic range o 25% of the normal pneumatic range o 50% of the normal pneumatic range o None of the above 9. The following physical phenomena are utilized with pressure measurement o Piezoresistive o String natural frequency o Buoyancy o All of the above 10.The main parts of the Smart instruments are: o Amplifier o Microprocessor o Low Pass Filter o ADC module o None of the above
B. True or False 10 Questions:
1. Positioner is to convert mechanical motion into electric/pneumatic signal o True o False 2. Span = LRV URV o True o False 3. Delta-V Control system can recognize and communicate with the traditional 4-20 ma Transmitter through its device manager software module o True o False 4. Fire resistant cable is mandatory to be used to control the Deluge Valves installed to protect condensate storage tank o True o False 5. Helical bourdon pressure gauge is the best local indicator to be installed on a 700 bar well head o True o False 6. Wheatstone Bridge is a basic component of the pressure gauge switch o True o False 7. Inclined manometer is perfect to detect small pressure variation o True o False 8. Shield cable is to be trimmed and insulated in the instrument side o True o False 9. FF Positioner can host the AI & PID control block o True o False 10.Differential pressure with 3 - 20 PSI range can detect a differential between 1300 & 1305 PSI pressure inputs o True o False