Most of the times, people have problems related to car/UPS batteries where they find it an

impossible task trying to justify their batteries are death within the first year. Normally they
try to visit local batterys shop where our illiterate technicians try their level best to convince
them that the battery is dead and only way out is to buy new batteries. They immediately
perform a load testing on discharged battery and show you where the needle is pointing
without informing you about the sort of load they have inserted on the battery or at times
they measure the reading of hydrometer of one or two cells then inform you regarding the
faulty cell without giving you a proper reason. Most of the times the battery is not dead or
acid within the battery does not have a right Specific Gravity or topped up with tap water.
These batteries can easily be brought back to life by performing a flush and then charging it
back for 2 to 3 times. If load testing is performed again on the same battery then you will be
surprised to see that your battery was not actually dead as he was trying to convince you
that it was dead. Secondly, the procedure which they follow in order to prepare the
Sulphuric Acid with gravity of 1270 has many faults which directly reduce your battery life to
half. Most of these problems reported (battery dies within a year of purchase) has directly to
do with the way you are maintaining your batteries. If your UPS has been trying hard to
charge an empty lead acid battery then I can guarantee that your battery will die
immediately and there is nothing you can do to bring it back to life.
Sometimes you must have noticed that your UPS is always charging, either of the reasons
may imply; because of sulphate built up on battery terminals (UPS is unable to deliver the
current which is required to charge a battery), or it does not have fluid inside it which is
necessary to charge the lead. In either scenario, you can very well understand that you are
wasting energy which should be sufficient enough to run two Air-conditioners during
summer season. As normal 145 AH battery needs 14-15 Amperes for charging where as
your home Air-Conditioner demands 8 to 9 Amperes of current once compressor is running.
So it is very important to maintain your batteries in order to avoid wasting the energy which
also can give you high bills. Normally, once you purchase a UPS along with batteries, then
you might notice a decrease in the output of UPS within first three months. Now my point
here is that this is very abnormal behavior which occurs in every house these days.
Different scenarios can cause similar problems as batteries convert chemical energy into

electrical energy and chemical properties of battery changes the entire year, so if you will
not cope up with the situation then you will experience similar scenarios of high electric bills
and battery will die within a year of purchase. This topic should catch an eye of Audience
who are using lead Acid batteries and local UPS being sold in every city. Further
explanation is given with help of personal experiment performed in my office compound.
Similar scenario occurred with me three years back once I got interested in analyzing the
procedure which is used by battery maintenance shops. They purchase Sulphuric Acid in
drums and then mix it with tap water in 66 % by volume. They say that chemical reaction
causes the water to boil which remove the oxygen molecules from the mixture hence results
in giving up gravity of 1250 which they pour it in car battery.
A battery runs fine for minimum 2 years, where as, if its all about removing impurities from
car battery then they are making a big mistake by adding tap water because it would boil
the water but shall not guarantee the removal of impurities present inside the water. I have
six batteries of 200 Amps each in my office which supports 15 computers running on them
during heavy load shedding. In order to overcome the myth, I purchased the drum of
Sulphuric Acid and mixed it with distilled water which I produced in my own lab. I took all my
batteries outside and flushed it with tab water to remove all the deposits present inside the
batteries. Flush was performed multiple times then batteries were refilled with Acid of 1280
gravity prepared within my office compound. From the past three years, I have been
maintaining the gravity of my UPS batteries with Specific Gravity of 1280 by mixing the acid
and distilled water as required. Even at the end of third year, my batteries are able to
provide 90% backup time as compared to the time of purchase, even after excessive load
shedding of 1 hours 5-6 times a day from last three years. Flush is a periodic exercise
which is performed at least once a year; I also have adjusted the output of my UPS to
charge per battery rate at not more than 8 Amps. Similar procedure was adopted on all my
three car batteries which have been running fine without a problem from last three years
with mileage exceeding 80000 km each.
Now common problems why Lead Acid battery dies earlier are as follow

1. If fluid inside your battery has dried and your system is still charging the battery, then you
would never be able to recover your battery.
2. Once you add Tab water inside your batteries, this causes your batteries to die earlier as
impurities present inside the tap water directly attack the cell of a battery, hence reduces the
capacity of battery to charge properly and deliver the same backup.
3. Deposits build up at the bottom of the battery or between the plates which cause the
short circuiting of leads and few cells die. Flushing the battery removes those deposits
between the plates, and this procedure should be adopted before any such incident occurs.
4. Specific gravity of the fluid inside the battery should be between 1200 -1275, that why
you notice a decrease in UPS output under load shedding. Ideally Specific Gravity should
be between 1250 -1275.
5. Sometimes Specific Gravity of UPS batteries is ok but you are not using distilled water.
6. Charging rate of UPS is very high which causes overcharging of batteries and your
batteries dont last longer.
7. Sometimes Sulphate buildup on battery terminals reduces the capacity to charge it self
and deliver the current required.
8. If batteries remain in discharged state for long duration of time then it becomes very
difficult to bring it back to the life.
In order to cope up with these situations, I would urge that you should always have distilled
water stored and Acid with gravity of 1280 prepared with distilled water. Use hydrometer to
test the specific gravity and add distilled water or Acid as required. You should also adjust
the output of UPS in order to avoid over charging of the battery as that is another major
reason when your battery die soon.
I have kept the topic fairly simple in order to provide you with basic information which can
help you make your battery last long. I dont intend to use any equations here as I would not

like to confuse the audience but if you are interested then you can make a search on
Google to know about the chemical reactions which occurs within a battery.
HOW TO PRODUCE DISTILLED WATER
It is very easy to produce distilled water at home. By distilled water we simply refer to the
water which is heated and changes into steam. Steam should be allowed to pass through
some system which can condense the steam so that it can change its form back into liquid
and this liquid can be collected in some separate container. This liquid will be free from all
sorts of impurities and is called distilled water.
Video below will you give you a fairly good idea.

HOW TO MIX ACID WITH DISTILLED WATER


Specific gravity is measured in (kg/cu.m) for your reference as I wont be repeating these
symbols during this topic afterwards. Water has a specific gravity of 1000 where as
Sulphuric acid has specific gravity of 1800. Once you mix 66% (in volume) of distilled water
in 34% (in volume) Sulphuric Acid then you should get a gravity of 1240. But normally you

end up getting a gravity of 1400 as lot of distilled water is evaporated during this process
due to heat being generated. You can make later adjustments using distilled water once
Acid has cooled down as at that time no heat will be generated. Always remember that
battery will show increased gravity once charged and reduced gravity once discharged.
Initially aim for gravity of 1250 and then you can take the reading after a week and make
fine adjustments.
1. Always pour Acid on distilled Water not distilled water on Acid.
2. Wear Rough Clothes, Glasses and gloves if possible.
3. Keep the Acid and Mixture out from the reach of Children.
4. Lot of heat would be generated during this process so be very careful.
5. Always Use plastic Container not Metal.
6. Mixture will take minimum 24 hours to cool down.
7. Never pour the mixture inside the battery once its hot.
8. 64 % distilled water should be Mixed with 36 % Acid by Volume.
9. You may end up getting a gravity of 1400.
10. Keep hydrometer with you and only check once fluid has cooled down.
11. You can perform later adjustments by pouring more distilled water on the mixture once it
has cooled down and at that time no heat will be generated.
12. Use Plastic bottles to store the mixture.
13. Always Label it as Very Dangerous Sulphuric Acid with Gravity ABC .
14. Keep it in safe place where no one other then you can touch it.

15. Container used for producing the mixture should never again be used for taking bath.
16. Dont allow anyone to misuse the Acid for hurting anyone.
HOW TO PERFORM FLUSH
Procedure which I followed was that I took the batteries outside and flushed it with tap water
5-6 times. People normally prepare the mixture of (Espom Salt + distilled water heated at 66
C). Pour the mixture inside the battery and then shake the battery so that mixture can make
its way to every cell. Once the mixture has cooled down then they charge the batteries for
several hours in order to remove sulphate deposits from batteries. . This procedure is used
to recondition old batteries which can still provide you with an output of minimum 10 Volts.
You will have to discharge and recharge it for multiple times. After a day or two, perform
another flush and then pour the new mixture of acid inside the battery.
HOW TO ADJUST UPS
Most of us are using the similar local UPS sold in market. The only problem with these UPS
is that they have few parameters which at times are not adjusted properly. Now once you
buy these UPS without testing them, then you may end up losing many electronic
equipments and since charging rate of UPS is not adjusted according to the battery which is
also why battery doesnt last longer.
By rule of thumb the correct charging rate of UPS is its Amp Hour rating divided by 10. For
145 AH battery; the correct charging rate is 145 AH/10 is 14.5 Volts. Anything above this
would be termed as fast charging which would damage your batteries in long run. Slow
charging is good for batteries but you have to prepare yourself for next load shedding.
You should always ask local UPS shops to adjust these parameters according to
specification given below. If you are interested in learning then ask him to do it in front of
you. Mark those parameters with paper tape so that you dont forget once you do it yourself.
1. These UPS have a PCB card which has many variables.

2. These variables can be adjusted using a screw driver.


3. During load shedding the Output of the UPS is much more than normal Voltage.
4. Adjust the variables such that your Output Voltage should never exceed 265 Volts once
batteries are fully charged.
5. Adjust such that once output voltage reaches 220 Volts then your UPS should trigger the
alarm and should shutdown within 10 seconds.
6. Adjust the charging rate of each battery such that (AMP HOUR rating divided by 10).
7. Slow charging is very good for batteries but if it is slower than Amp Hour rating divided by
10 then you may not be prepared for next load shedding.
8. UPS should stop charging your batteries once the output voltage of both the batteries
reaches 28 Volts.
9. During Load shedding, once output of batteries (where two batteries are connected in
Series) reaches 20 Volts then Alarm should be triggered and UPS must be shut down
immediately. Also note the output of UPS at that instance as it should not be less than 220
Volts otherwise you will end up losing many electronic equipments.
10. Always keep your UPS line separate from main line.
11. Your UPS should shutdown immediately if load exceeds the maximum capacity. UPS
shops have different bulbs installed on board with different Powers.
12. Always test under full load so that you are aware about the maximum load your UPS
can take. Now, your computers should be safe under these configurations.
13. You will need a good quality Voltmeter and AMP meter.

14. Since chemical properties of batterys changes the entire year so you will have to check
your tuning after every few months which you can easily do with help of a Voltmeter, Ampmeter & hydrometer.
15. Always remember that current divides in parallel configuration and Voltage remains
same in parallel configuration so you should add many batteries on your UPS in parallel or
series configuration which ever suits the configuration.
TECHNICAL TERMS
You should be aware of these terms as they are very simple and will give you the right idea
about the correct charging and discharging rate of lead Acid batteries. Lead Acid batteries
are ideal for scenarios where your load demands very high current for short duration of time
such as starting the car thats why many people are interested in knowing CCA or CA rating
of battery before buying them.
COLD CRANKING AMPERES (CCA)
Cold Cranking Amperes (CCA) is measure of amount of current your battery can deliver at 0
F for 30 seconds, once both terminals of battery are shorted and voltage does not drop
below 7.2 Volts for 12 Volts battery.
CRANKING AMPERES (CA)
Some time battery comes with CA rating specified for 32 F. high CCA rating is typically used
for starting application but not referred to deep cycle batteries.
Never short your battery terminals as lot of heat is generated during this process and you
may end up destroying your batteries but this is exactly what happens once you start your
car. Also note that this is how a load testing is performed.
AMP HOUR RATING
Normal batteries available in market come with AH (AMP HOUR) rating which means that
145 AH battery can deliver 7.2 Amperes for 20 hours before it would need serious charging

again or 14.5 AMPS for 10 hours before it requires charging again. AH rating is expressed
in number of amperes a battery can deliver for 20 hours which is calculated by dividing AH
rating by 20.
DISCHARGING RATE
In order to get the best service from your batteries the batteries should not be discharged at
a rate more than AH/10, for 145AH battery is 145 AH/10 =14.5 Amperes. But it is ok to
discharge a battery with AH rating divided by 6, 4 ,3 so this means that you can discharge
your 145 AH battery at rate 145/6= 24 AMPS , 145/4=36 AMPS, 145/3= 48 AMPS but dont
expect it to last for 4 hours. In case of UPS, I am unaware how much load you have
inserted and number of batteries you are using in parallel or series but you can use Ampere
meter to observer the load on your batteries during load shedding and if you see that the
rate on each battery is more then try to add more batteries to your UPS as current divides in
parallel.
CHARGING RATE
When you are charging your batteries then right rate to charge a battery is youre AH rating
divided by 10. That for 145 AH battery the right charging rate should be 145/10=14.5
Amperes. Slower charging is good for batteries but you have to be prepared before next
load shedding. Anything above AH/10 is termed as fast charging which would damage your
batteries in long run but you can do it for few times if your are monitoring the process.
CONCLUSION:
Entire purpose of this topic was to highlight the mistake which our illiterate technicians are
making while selling the batteries which reduces the life of your battery to half at times once
you purchase it. Secondly, topic has also highlighted mistakes which general public is
making while dealing with batteries as they die sooner and they are wasting a lot of power
which can comfortably run two Air-conditioners once, they are mismanaging the system. I
dont recommend you to prepare the Acid by your own self as this is a very risky task where
individual can easily hurt himself but least you can do is use distilled water, check Specific

Gravity of Acid inside batteries by using hydrometer, clean battery terminals on time and
maintain a proper tuning of UPS.