KCM-II

KCM-II marine diesel engine


Host instrument box

USER'S MANUAL

CCEC

KCM-II

Instrument Box User's Guide Contents


One Warning
Two Introduction
KCM-II three. KCM-II-type instrument, control switch, layout
four. Alarm indicator configuration
1. Instrument box pre-alarm and other indicators
2. Alarm parking

Fives. Relay alarm extension output interface and control connection


board
KCM-IIR six. KCM-IIR remote meter box
Control panel instrument, switch and alarm indicator configuration
1. diagram
2. KCM-IIR Equipped with KCM-IIR remote meter box can achieve the function
Seven. The basic requirements and precautions for the installation and

use of instrument box
KCM-II Eight. KCM-II operation and precautions

1. 1. Check before starting


2. 2. Instrument power observation
3. 3. Start the operation
4. 4. Run
5. 5. Parking
6.
7. 7. Precautions

6.How to determine and deal with the engine running the alarm
problem

nine. Electrical Trouble, Cause and Treatment of Diesel Engine

During Operation
1.

1. There is no display when the instrument box is powered on

2. 2. The host can not boot


3. 3. The meter display flashes and is unstable
4. 4. Tachometer reading is not correct or alarm stop
5. 5. Tachometer display is unstable or no indication
6. 6. Oil pressure gauge no indication of alarm or full scale

7. Water temperature or oil temperature gauge no indication or


full scale alarm
8. 8. Exhaust thermometer no indication and low voltage and
high temperature alarm lights
9. 9. Remote table power no indication, can not be far start and stop
7.

10. After power-on, speed 10.


indicator, low oil pressure, 11.
11. Emergency stop after
12. 12. Diesel engine after low oil pressure,
power on, the oil
high oil temperature and water temperature
13.
temperature is high,
red indicator flashes, but does not stop
the other standby 13. Idle oil pressure alarm or alarm shutdown can not speed
indicator is lit (not flashing)

appendix

1.

2. KCM-IIR
3.
4. KCM-IIR 4913984
5. KCM-II 4913983
6. KCM-II 4914113

1. Model and speed alarm point switch setting diagram


2. KCM-IIR remote meter box outline drawings and installation hole size
3. Connect the meter to the remote
meter
2
4. KCM-IIR Electrical Circuit Diagram (for instrument case part number: 4913984)
5. KCM-II Electrical Circuit Diagram (for instrument case part number: 4913983)
6. KCM-II Electrical Circuit Diagram (for instrument case part number: 4914113)

CCEC
First, the warning:

24V
28


KCM-II CCS

KCM-II 4913983
NTA855K19
KCM-II 4914113 K38K50
KCM-IIR 4913984

1.

2.

3.

4.

CCEC
KCM-II
1.

0r/min-3000r/min
2

50 /

0h-10000h 1h

60-120

2/

60-150

3/

0MPa-0.8MPa
P0.4MPa 0.02MPa/
P0.4MPa 0.04MPa/

0-700

10/

20V-32V 0.4V/

2.5 0.5
2.

//

/4914113


1.

T962

P0.12MPa0.02MPa

T1153

V22V V30V

n575r/min

CCEC

2.

Ne=1744r/min n2092r/min
Ne=2027r/min n2432r/min

T992

P0.1MPa0.02MPa
680r/min

8 KCM-IIR
PC RS485 2 RS485/232

24V 2
4
26 250V 2A32V 2A

KCM-IIR
KCM-IIR
1. KCM-IIR KCM-II
2. RS485
3.
4.
5.
6.
5

CCEC
7.


1.
553
95%
39m/s
24V4V

2.

101 2

KCM-II
1.
/
/
/
6

CCEC
2.

3.
/
n>350r/min

4.

680r/min
n350r/min

5.

/
K38K50

6.

IC

CCEC

A-B

A-B 0.1MPa

7.

CCEC

3 /

4 2#3#
24V

2 24V

2 2# 24#

24V

4 24V

4 /

6 K38K50

5
6 /

CCEC

1 8090

200110

2K

10

CCEC

3 3# 4#

1 DB+ DB-

2 KCM-II/

2KCM-II

11

CCEC

3 K38K50

3 /

0000

12

1 2
KCM-II
NTA-Ne1744

NTA-Ne2027

KTA-Ne1744

KTA-Ne2027

2KCM-IIR
3
4KCM-IIR 4913984
5KCM-II 4913983
6KCM-II 4914113

KCM-II/IIR MARINE ENGING METERS


INSTRUCTION

FORWORD
KCM-II/IIR meters box is used for marine engine. It accords with CCS
and meets the requirements of shipbuilding.
This product contains two types:
1. KCM-II

It is main meters box on engine.


P/NO: 4913985

2. KCM-IIR It is a remote meters box.


P/NO: 4913986

GAGE SET OF KCM-II/IIR(Refpanel)


1. Tachometer

03000r/min 2(digital indicator)

2. Hxhaust temperature

0640

10/ind

3.

Hour meter

09999h

1h

4.

Water temperature

60120

2/ind

5.

Oil temperature

60150

3/ind

6.

Oil pressure

00.8MPa

0.02MPa/ind(P0.4MPa)
0.04MPa/ind(P0.4MPa)

7.

Battery voltage

2032V

0.4V/ind

All meters accuracy are better than 2.5%FS.


Power source: 24V DC10%

SWITCH SET OF KCM-II (RefPanel)


1Power switchcontrol power ON/OFF and stop engine normally.
2Mpower/Apower switchselect main power or auxiliary power
Source for Gage box.
3Starting buttonpush to crank engine.

4Protect ON/protect OFF switchselect protect ON for normal


running or protect OFF for
running in an emergency.
5Remote start/start switchselect engine to run at high speed
or idle.

SWITCH SET OF KCM-IIR (RefPanel)


1Power/start switchcontrol power OFF or ON and start engine
remotely.
2Remote stop switchuse to stop engine remotely.
3Quit switchto cut off alarm sound.
4H.brightness/L.brightness switchto select L.B at night.

ALARM AND LAMP SET


1. Shut down engine and indictor
Over speed (SPHRed Lamp)

Ne=1744r/minn2092r/min

(by tachometer to monitor)

Ne=2027r/minn2432r/min

Note: a button on main control board is pushed down to degrade


alarm value 15% for testing over speed alarm function
(power off to set).
Water temperature high (WTHRed Lamp)

T1062

(by temperature alarm switch to monitor)


Oil pressure low (OPLRed Lamp)

P0.12MPa0.02

(by pressure alarm switch to monitor)


2. Meters alarm and indictor
Water temperature high (WTHYellow lamp)
Oil pressure low (OPLYellow lamp)

T982
P0.14MPa0.02

Battery voltage high or low (BV2 Colors Lamp)


V22VYellow lamp ; V30VRed Lamp

Water level low (WLLRed Lamp)


(have to install a level switch on engine)
Water pressure low (WPLRed Lamp)
(have to install a pressure switch on engine)
Motor starting gas pressure low (APLRed Lamp)
(have to install a pressure switch on engine)
Running indictor (RUNYellow lamp) when n800r/min
Stop indictor (STOPRed Lamp)
where push down the stop button or switch.
Auxiliary power (APRed Lamp)
when auxiliary power is used.

ALARM OUTPUT AND CONTROL BOARD IN KCM-II


This board supplies all alarm output and some control terminals for
customer to use (RefFigure 6)
1. 8 terminals use to connect the KCM-IIR remote meter box.
2. 2 terminals use to connect PC computer when want to transmit
the measuring data from KCM-II to it (should use a RS485/232
transducer and programmer according to the agreement of
KCM-II).
3. 2 terminals to connect auxiliary power.
4. 4 terminals to connect emergency stop button and indicator
from outside.
5. 26 terminals without power use for all the alarm signals to
connect out.
(The alarm relays contacts capability are AC 350V 5A DC 32V
1A.they are can be used to connect outer relay and indictor.)

THE FUNCTIONS OF KCM-IIR WITH KCM-II MAIN


METER TO USE
1. KCM-IIR can indicate same measuring reading and alarm with
KCM-II synchronous.
2. KCM-IIR works with KCM-II by date communication, that couldnt
to install any sensor.
3. Use the power switch can to control power ON or OFF and start
engine remotely.
4. Quit switch can cut off alarm sound.
5. Stop switch can stop engine remotely.
6. H.B/L.B switch can to select the display brightness of meters.

INSTALLATION REQUIRENTS FOR KCM-II


The KCM-II couldnt work at over limit for long time.
1. The work temperature 573
2. Humidity 95%
3. Vibration 39m/s
4. No more electromagnetic disturbance.
NOTE: If the meters reading are influenced by intense vibration
when engine is running, suggest the customer to take off box from
engine and hang up it.

PROTECTION TO ELECTROMAGNETIC DISTRUBANCE


KCM-II box has ability to protect electromagnetic disturbance, just
some requirements are needed when KCM-IIR works with it:
1. Should use a cable 81 with shield and connect an end of
shield to a screw of KCM-IIR.

2. If it works with computer should use twine wire cable with shield
and an end connect to a screw of KCM-II.
3. The connection cable of KCM-II and KCM-IIR couldnt array with
main power cable.
4. KCM-II and KCM-IIRs connection terminals Refdiagram.

OPERATION
1. Preset on panel
Put MP/AP power switch to Mpower side.
Protect ON/Protect OFF switch to ON position.
Remote start/start switch set start position.
2. Turn on power to check
When power is on, almost alarm lamps are flash about 1 second
for checking them .2 second after just voltage and hour meters
have reading.
Look at if any alarm lamp is lighted, otherwise to check.
3. Start engine
Push down starting button to crank engine, when its speed up
to 350r/min the controller will cut off the motors circuit. The
operator just take up hand.
4. Run engine
After engine is started, let it to run at IDLE speed 2
3minuts.
Make engine running at high speed.
When engine runs a time all meters will have readings.
NOTE: Only engine speed up to 800r/min, RUN lamp is lighted
and all alarms sets are activation.

5. Stop engine
Normality to stop engine just turn power switch to OFF.
At a urgent condition to shut down engine can use the Remote
Stop switch on KCM-IIR or Emergency Stop button some where
is installed it.
Engine will be stop when over speed or water temperature high
or oil pressure low alarm is happened.
At urgent condition if couldnt shut down the engine,
put the switch to protect OFF position.

NOTES FOR OPERATION


How to open and close the panel of box:
Push down the two bars on panel and turn 90 to inside by hands
to open. Otherwise push down bars and turn 90to outside close
the panel of box.
Dont turn ON and OFF the power switch frequently, have to 5
seconds to turn ON again after turn OFF, otherwise the
meters may be damaged.
Dont take in and off the connectors of engine wiring with power,
especially for 3P connector.
After test over speed alarm function with the button on main
control board, have to reset it before turn on power again.

TROUBLE SHOOTING
Symptom: Turn ON power no display or unstable

Cause

Solution

1 Battery connection error.

1 Change the battery connection wires.

2 Engine wires connector doesnt

2 Take off and push it again.


3 Put the switch to Mpowers side.

touch well.
3 MP/AP switch set Apower.
4 24V/5V

power

transducer

4 Replace a main circuit board.

has

trouble on main circuit board.

Symptom: Engine cranks but will not start

Cause

Solution

1 No fuel to cylinder head.

1 Loosen fuel line at cylinder head while cranking


engine. Check fuel line and valves.

2 No power at shut off valve.


3 Shut off valve has trouble.

2 Check MP/AP switch if set to MP position.


3 Manually open shut off valve.

Symptom: Engine speed unstable

Cause
Fuel system has trouble.

Solution
Check fuel linepump.

Symptom: Tachometers reading not correction

Cause

Solution

A switch setting not correction for

To set the switch again refto a figat small blocky

engine type at main circuit board.

square.

Symptom: Oil pressure meter no reading or full scale

Cause
The pressure sensor has trouble.

Solution
Replace a new one.

Symptom: Water and oil temperature meter no reading or full scale

Cause
Temperature sensor breakage.

Solution
Replace a new one.

Symptom: Turn on power SPH, OPL, WTH, RUN, B.V lamps are brightened
not flash

Cause
A red IC on display board has trouble.

Solution
Replace new one.

Symptom: Turn on power WLL, WPL, APL, STOP, OTH, lamps are
brightened not flash

Cause
A blue IC on display board has trouble.

Solution
Replace new one.

Symptom: Engine runs-OPL or WTH lamps flash.

Cause
A yellow IC has trouble on main control

Solution
Replace new one.

board.

Symptom: Engine stop by OPL or WTH alarm switch the lamp not flash.

Cause
A yellow IC has trouble on main control

Solution
Replace new one.

board.

Symptom: Exhaust meter no reading and other Gages reading are


degraded.
Cause
The thermocouple cause had broken.

Solution
Replace new one.

Symptom: Can not to start or stop the engine or display at KCM-IIR


panel

Cause

Solution
Check and correct wires refto Fig7

Connection wires between KCM-II and


KCM-IIR have error.

NOTE: Above judgments are based on more meters work well, otherwise
check the power or replace a main circuit board.

REFER FIGURES
1. switchs set of engine type and speed alarm point

NOTE: Switch 1# to set speed alarm point


Switch 2# to set GSET type.
KCM-II
NTA-Ne1744

NTA-Ne2027

KTA-Ne1744

KTA-Ne2027

2. Fig1 KCM-II outline and installation size.


3. Fig2 KCM-IIR outline and installation hole size.
4. Fig3 KCM-II electrical principle diagram.
5. Fig4 KCM-II electrical connection diagram.
6. Fig5 KCM-IIR electrical principle and connection diagram.
7. Fig6 Alarm output and control boards terminals.
8. Fig7 Main box with Remote Gage connect diagram.