BILL NO.

'F5' - SUMMARY OF TENDER - WATER MAIN RECTICULATION (ALL PROVISIONAL)


ITEM

DESCRIPTION

UNIT

QTY

RATE (RM)

WATER MAIN RETICULATION (ALL PROVISIONAL)

Excavate trench for 150mm diameter pipe 650mm wide


not exceeding 1.50m deep and average 1.35m deep and
get out, part return, fill in and ram, deposit and spread in
making up levels where directed within the site and
remainder load and cart away

643

Ditto 200mm diameter pipe 700mm wide ditto

326

Well compacted sand bedding 650mm wide under and all


around 150mm diameter pipe with a minimum of 150mm
thick under and 150mm thick above pipe, 250mm thick to
sides of pipe

481

Ditto 650mm wide under and all around 150mm diameter


pipe with a minimum of 150mm thick under pipe, 600mm
thick above, 250mm thick to sides of pipe

136

Ditto 700mm wide under and all around 200mm diameter


pipe with a minimum of 150mm thick under and 150mm
thick above pipe, 250mm thick to sides of pipe

312

Ditto 700mm wide under and all around 200mm diameter


pipe with a minimum of 150mm thick under pipe, 600mm
thick above, 250mm thick to sides of pipe

Concrete Grade 15 bedding 450mm wide under and all


around 150mm diameter pipe with a minimum of 150mm
thick under pipe and above pipe, 150mm thick to sides of
pipe

26

Ditto 500mm wide under and all around 200mm diameter


pipe ditto

Mass concrete Grade 25 as described thrust block


including all necessary formwork and excavation
J

300mm x 300mm x 300mm Thick (overall)

No.

500mm x 450mm x 400mm Thick (overall)

No.

10

650mm x 450mm x 500mm Thick (overall)

No.

750mm x 600mm x 550mm Thick (overall)

No.

800mm x 450mm x 400mm Thick (overall)

No.

1150mm x 450mm x 500mm Thick (overall)

No.

11

To Collection :

647.11/Int.Infra

- F5/1 -

AMOUNT (RM)

BILL NO. 'F5' - SUMMARY OF TENDER - WATER MAIN RECTICULATION (ALL PROVISIONAL)
ITEM

DESCRIPTION

UNIT

QTY

RATE (RM)

WATER MAIN RETICULATION (ALL PROVISIONAL)


(CONT'D)

Reinforced concrete Grade 25 pier support for 150mm


diameter pipe crossing comprising 1550mm x 1500mm x
400mm base reinforced with and including 12mm
diameter high tensile bottom bar spaced 200mm centre
one way and 150mm centres another way, 12mm
diameter top bar spaced at 200mm centres one way and
300mm centre another way, 550mm x 300mm thick x
2000mm high concrete pier complete with and including
16mm diameter high tensile horizontal bar spaced at
150mm centre both face, 12mm diameter high tensile
vertical bar spaced at 200mm centres both face, including
50mm thick lean concrete to base, formwork and
excavation

No.

Ductile iron pipe to BS EN 545 : 2002 Class 40 with


sockets and spigot, plain ends and flanged ends as
described with and including 'Viking Johnson' flexible
coupling joint or other equal and approved
B

150mm Diameter double flanged pipe laid and jointed in


trench (measured separately)

643

Extra for 45 degree bend

No.

Ditto 90 degree bend

No.

Ditto 150mm x 150mm tee

No.

Ditto 150mm x 100mm special tee

No.

Ditto for branch air valve tee

No.

200mm Diameter double flanged pipe laid and jointed in


trench (measured separately)

326

Extra for 45 degree bend

No.

Ditto 90 degree bend

No.

Ditto 200mm x 150mm tee

No.

Ditto for branch air valve tee

No.

100mm Diameter double flanged pipe laid and jointed in


trench (measured separately)

100mm Diameter double flange short piece 450mm long

No.

100mm Diameter ditto 1000mm long

No.

No.

Flange adaptor for 100mm diameter pipe

To Collection :

647.11/Int.Infra

- F5/2 -

AMOUNT (RM)

BILL NO. 'F5' - SUMMARY OF TENDER - WATER MAIN RECTICULATION (ALL PROVISIONAL)
ITEM

DESCRIPTION

UNIT

QTY

RATE (RM)

WATER MAIN RETICULATION (ALL PROVISIONAL)


(CONT'D)

Double flange scour valve in ductile iron body as


described and complete with 'Viking Johnson' coupling,
galvanised iron gibault joint and including all necessary
accessories and jointing to 150mm diameter pipe

No.

Double flange sluice valve in ductile iron body as


described and complete with ditto and jointing to 200mm
diameter pipe

No.

No.

Double orifice controllable air valve as described and


jointing to 200mm diameter pipe and complete with
double flanged butterfly valve, 200mm diameter x 250mm
long flanged ended extension piece, ditto

No.

Pipe reserve marker post constructed of 50mm diameter


x 750mm high ABS Class '9' pipe with full flange on one
end and planting 200mm deep complete with and
including 200mm x 200mm x 200mm thick mass concrete
Grade 20 as described footing, 50mm diameter end cap,
sign stickers and all necessary excavation and formwork
as per Engineer's detail

No.

15

No.

No.

Double orifice controllable air valve as described and


jointing to 150mm diameter pipe and complete with
double flanged butterfly valve, 150mm diameter x 250mm
long flanged ended extension piece, all necessary
coupling, jointing, and all necessary accessories

SCOUR VALVE CHAMBER


F

Standard precast concrete Grade 25 as described


inspection chamber overall size 560mm x 480mm x
750mm high constructed of top, middle and bottom
section bedded and jointed in cement and sand (1:3),
900mm thick compacted sand and granular material bed,
complete with and including precast composite cover
(Type 3) constructed of 3mm thick steel plate tray infilled
with concrete, lifting handles and all necessary excavation

SLUICE VALVE CHAMBER


G

Standard precast concrete Grade 25 as described


inspection chamber overall size 840mm x 760mm x
750mm high constructed of top, middle and bottom
section bedded and jointed in cement and sand (1:3),
900mm thick compacted sand and granular material bed,
complete with and including precast composite cover
(Type 3) constructed of 3mm thick steel plate tray infilled
with concrete, lifting handles and all necessary excavation

To Collection :

647.11/Int.Infra

- F5/3 -

AMOUNT (RM)

BILL NO. 'F5' - SUMMARY OF TENDER - WATER MAIN RECTICULATION (ALL PROVISIONAL)
ITEM

DESCRIPTION

UNIT

QTY

RATE (RM)

WATER MAIN RETICULATION (ALL PROVISIONAL)


(CONT'D)

AIR VALVE CHAMBER


A

Standard precast concrete Grade 25 as described


inspection chamber overall size 84mm x 760mm x
750mm high constructed of top, middle and bottom
section bedded and jointed in cement and sand (1:3),
900mm thick compacted sand and granular material bed,
complete with and including precast composite cover
(Type 3) constructed of 3mm thick steel plate tray infilled
with concrete, lifting handles and all necessary excavation

No.

460mm x 460mm x 225mm Thick mass concrete Grade


25 as described platform including all necessary
excavation and formwork

No.

275mm x 275mm x 275mm Thick mass concrete Grade


25 as described thrust block including all necessary
excavation and formwork

No.

No.

Standard precast concrete Grade 25 as described


inspection chamber overall size 560mm x 480mm x
700mm high constructed of top, middle and bottom
section bedded and jointed in cement and sand (1:3),
500mm thick compacted sand and granular material bed,
complete with and including precast composite cover
(Type 3) constructed of 3mm thick steel plate tray infilled
with concrete, lifting handles and all necessary excavation

No.

100mm Diameter approved double pillar fire hydrant to


B.S. 750 with 63.5mm diameter outlet complete with
chain and metal cap and including all accessories and
painting to exposed surfaces with two coats of approved
gloss paint

No.

Sluice valve (Type B) in ductille iron body and jointing to


100mm diameter pipe

No.

100mm Diameter flange ended ductile iron pipe average


750mm long as extension pipe

No.

21

150mm x 150mm x 100mm Flanged ended 'tee' in ductile


iron body and jointing to pipe

No.

100mm Diameter double flanged ductile iron 90 degree


duct foot bend

No.

100mm Diameter Flange adaptor

No.

THE FOLLOWING IN PILLAR HYDRANT


B

D
E

250mm x 150mm x 380mm Thick ditto

(End of Pillar Hydrant)

To Collection :

647.11/Int.Infra

- F5/4 -

AMOUNT (RM)

BILL NO. 'F5' - SUMMARY OF TENDER - WATER MAIN RECTICULATION (ALL PROVISIONAL)
ITEM

DESCRIPTION

UNIT

QTY

RATE (RM)

WATER MAIN RETICULATION (ALL PROVISIONAL)


(CONT'D)

THE FOLLOWING IN BULK METER


A

100mm Thick mass concrete Grade 25 as described in


concrete bed

M2

Layer of steel fabric reinforcement to M.S. 145 as


described (BRC Ref. No. A10-weighing not less than
6.16kg. per square metre) well lapped at joints and
embedded in bed (measured nett-no allowance made for
laps)

M2

Sawn formwork as described to edge of concrete not


exceeding 100mm high

12

150mm x 300mm Wide x 700mm high mass concrete


support including all necessary formwork and render
smooth on all exposed surfaces

No.

No.

Double flange ductile iron pipe to BS EN 545 : 2002 Class


40 including all necessary jointing and coupling and
painting with two coats of approved polyurethane paint
E

150mm Diameter pipe laid and jointed vertically

Extra over for 90 degree bend

200mm Diameter pipe laid and jointed vertically

Extra over for 90 degree bend

No.

150m Diameter short piece 450mm long including 'Viking


Johnson' flexible coupling joint

No.

150m Diameter ditto 900mm long ditto

No.

200m Diameter ditto 600mm long ditto

No.

200m Diameter ditto 1200mm long ditto

No.

150mm Diameter double flanged ductile iron gate valve to


SYABAS approval and jointing to pipe

No.

200mm Diameter ditto

No.

150mm Diameter double flange T-pot strainer as


described and jointing to pipe including all necessary
approved joint

No.

200mm Diameter ditto

No.

----------------------N

To Collection :

647.11/Int.Infra

- F5/5 -

AMOUNT (RM)

BILL NO. 'F5' - SUMMARY OF TENDER - WATER MAIN RECTICULATION (ALL PROVISIONAL)
ITEM

DESCRIPTION

UNIT

QTY

RATE (RM)

WATER MAIN RETICULATION (ALL PROVISIONAL)


(CONT'D)

THE FOLLOWING IN BULK METER (CONT'D)


A

150mm Diameter 'SYABAS' approved double flanged


bulk meter with and including approved joint and liaison
with authority in connection therewith

No.

200mm Diameter ditto

No.

Allow all cost for jointing to existing main supply pipe


including all necessary excavation and making good all
works disturbed

Item

On completion of water main reticulation system, test all


piping and fittings etc., make good any defects and leave
the whole in perfect working order to the entire
satisfaction of the Architect

Item

B
(End of Bulk Meter)

To Collection :

COLLECTION
From Page F5/1

From Page F5/2

From Page F5/3

From Page F5/4

From Page F5/5

From Page F5/6

TOTAL BILL NO. 'F5' - SUMMARY OF TENDER - WATER MAIN RECTICULATION (ALL
PROVISIONAL) - CARRIED TO GENERAL SUMMARY OF TENDER E/1 :

647.11/Int.Infra

- F5/6 -

AMOUNT (RM)