You are on page 1of 130

Shoaiba Steam Power Plant

Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
14
14
14
14
13
12
14
13
12
14
13
12
14
13
12
14
13
12
14
13
12
14
13
12
14
13
12
14
13
12
14
13
12
14
14
14

LBA
LBA
LBA
LBA
LBA
LBA
LBB
LBB
LBB
MAN
MAN
MAN
LBC
LBC
LBC
LBC
LBC
LBC
LBC
LBC
LBC
LBG
LBG
LBG
LBG
LBG
LBG
LBG
LBG
LBG
LBG
LBG
LBG
SCB
SCB
SCB

21
21
21
21
21
21
21
21
21
10
10
10
15
15
15
30
30
30
90
90
90
05
05
05
15
15
15
30
30
30
60
60
60
20
20
20

AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA

Techno Code
202
202
202
202
202
202
202
202
202
202
202
202
212
212
212
204
204
204
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202

M70_002_025
M70_002_025
M70_002_025
M70_002_025
M70_002_025
M70_002_025
M70_003_025
M70_003_025
M70_003_025
M70_003_025
M70_003_025
M70_003_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_005_025
M70_005_025
M70_005_025
M70_006_025
M70_006_025
M70_006_025
M70_006_025
M70_006_025
M70_006_025
M70_006_025
M70_006_025
M70_006_025
M70_007_025
M70_007_025
M70_007_025

Designation / Type

Supplier

Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22


Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetalic Thermostatic Trap-CL2500-SW-NB25-A182 F22
Bimetalic Thermostatic Trap-CL2500-SW-NB25-A182 F22
Bimetalic Thermostatic Trap-CL2500-SW-NB25-A182 F22
Bimetalic Thermostatic Trap-CL2500-SW-NB25-A182 F22
Bimetalic Thermostatic Trap-CL2500-SW-NB25-A182 F22
Bimetalic Thermostatic Trap-CL2500-SW-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetelic Thermostatic Trap-SW-CL2500-NB25-A182 F22
Bimetalic Thermoststatic trap-CL2500-SW-NB25-A182 F22
Bimetalic Thermoststatic trap-CL2500-SW-NB25-A182 F22
Bimetalic Thermoststatic trap-CL2500-SW-NB25-A182 F22
Bimetalic Thermostatic trap-CL600-SW-NB25-A105
Bimetalic Thermostatic trap-CL600-SW-NB25-A105
Bimetalic Thermostatic trap-CL600-SW-NB25-A105
Bimetalic Thermostatic trap-CL600-SW-NB25-A105
Bimetalic Thermostatic trap-CL600-SW-NB25-A105
Bimetalic Thermostatic trap-CL600-SW-NB25-A105
Bimetalic Thermostatic trap-CL600-SW-NB25-A105
Bimetalic Thermostatic trap-CL600-SW-NB25-A105
Bimetalic Thermostatic trap-CL600-SW-NB25-A105
Ball Float Trap-CL150-FLG-NB25-A216WCB
Ball Float Trap-CL150-FLG-NB25-A216WCB
Ball Float Trap-CL150-FLG-NB25-A216WCB

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Drawing

Type of Doc
List of Data Sheets & Sectional drawings
Sectional drawing
Data Sheet
Installation, operation and maintenance instruction

List of Data Sheets & Sectional drawings


Sectional drawing
Data Sheet

Customer Doc. No.


80-L-M-36328
See 80-L-M-36328
See 80-L-M-36328
See sectional Drawing
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 80-L-M-36328
See 80-L-M-36328
See 80-L-M-36328
page : 2/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 2 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
14
13
12
14
13
12
14
14
13
13
12
12
80
80
80
80
14
14
14
14
14
14
14
14
14
14
13
13
13
13
13
13
13
13
13
13

SCB
SCB
SCB
SCB
SCB
SCB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

20
20
20
20
20
20
33
33
33
33
33
33
33
33
32
32
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33

AA
AA
AA
AA
AA
AA
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
202
202
202
204
204
204
511
551
511
551
511
551
511
521
511
521
511
512
513
514
515
521
522
523
524
525
511
512
513
514
515
521
522
523
524
525

M70_007_025
M70_007_025
M70_007_025
M70_007_025
M70_007_025
M70_007_025
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020

Designation / Type

Supplier

Ball Float Trap-CL150-FLG-NB25-A216WCB


Ball Float Trap-CL150-FLG-NB25-A216WCB
Ball Float Trap-CL150-FLG-NB25-A216WCB
Ball Float Trap-CL150-FLG-NB25-A216WCB
Ball Float Trap-CL150-FLG-NB25-A216WCB
Ball Float Trap-CL150-FLG-NB25-A216WCB
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105

Drawing

Type of Doc

Douglas-Italia S.p.A. Installation, operation and maintenance instruction


Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Customer Doc. No.


6E161114-E-1
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
page : 3/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 3 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
12
12
12
12
12
12
12
12
12
12
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QFA
QFA
QFA
QFA
QFA
QFA
QFB
QFB
QFB
QFB
QFB
QFB

33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
32
32
32
32
32
32
32
32
04
06
06
08
16
18
01
02
02
02
02
02

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
511
512
513
514
515
521
522
523
524
525
511
521
531
532
533
534
541
542
543
544
551
552
553
554
205
206
215
205
205
205
205
203
205
208
212
218

M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020

Designation / Type

Supplier

Bimetalic Thermostatic trap-CL300-SW-NB20-A105


Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Bimetalic Thermostatic trap-CL300-SW-NB20-A105
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
page : 4/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 4 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB

02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
222
226
230
234
242
247
251
253
259
261
265
267
269
271
237
240
273
275
277
279
281
283
285
287
289
291
293
311
313
315
317
319
321
323
325
327

M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020

Designation / Type

Supplier

Ball Float Trap-CL150-NPT-NB20-A216WCB


Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB
Ball Float Trap-CL150-NPT-NB20-A216WCB

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
page : 5/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 5 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
12
12
12
13
13
13
14
14
14
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QFB
QFA
QFA
QFA
QFA
QFA
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB

02
10
20
30
40
50
33
33
33
33
33
33
33
33
33
32
32
32
32
32
32
32
32
32
32
32
33
33
33
33
34
34
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
329
205
205
205
205
205
202
204
241
202
204
241
202
204
241
203
210
214
218
222
224
227
235
239
243
247
202
206
210
234
202
205
208
232
242
317

M70_101_020
M70_102_025
M70_102_025
M70_102_025
M70_102_025
M70_102_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025

Designation / Type

Supplier

Ball Float Trap-CL150-NPT-NB20-A216WCB


Ball Float Trap-CL150-NPT-NB25-A216WCB
Ball Float Trap-CL150-NPT-NB25-A216WCB
Ball Float Trap-CL150-NPT-NB25-A216WCB
Ball Float Trap-CL150-NPT-NB25-A216WCB
Ball Float Trap-CL150-NPT-NB25-A216WCB
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14SCB20AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
page : 6/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 6 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
89
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB

34
34
34
34
32
34
34
34
34
34
34
34
34
34
34
34
34
34
34
35
35
35
35
35
35
35
35
36
36
36
36
36
36
36
36
11

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
322
327
332
312
249
209
211
213
215
217
219
221
223
225
227
229
235
239
240
202
204
206
208
210
212
214
216
202
204
206
208
210
212
214
216
202

M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_105_025

Designation / Type

Supplier

Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL300-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
page : 7/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 7 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
89
89
89
89
89
89
89
89
89
89
89
89
80
80
80
12

QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLC

11
11
12
12
12
12
12
12
12
12
12
13
21
22
22
22
22
22
22
23
20
20
20
20
20
20
20
20
20
20
20
20
22
22
22
01

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
212
222
110
202
205
207
209
212
216
220
224
202
202
209
210
211
212
216
220
202
202
206
211
213
214
221
225
229
233
235
237
239
217
218
213
202

M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_108_080

Designation / Type

Supplier

Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted bucket-CL300-SW-NB25-A105
Inverted Bucket-CL600-BW-NB80-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
page : 8/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 8 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
12
12
12
13
13
13
13
14
14
14
14
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QFA
QFA
QFA
QFA
QFA
QFA
QFA
QFA
QFA
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB

01
02
02
01
01
02
02
01
01
02
02
02
03
04
04
04
04
06
06
08
16
18
01
02
02
02
02
02
02
02
02
02
02
02
02
02

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
204
202
204
202
204
202
204
202
204
202
204
002
002
201
201
201
201
202
211
201
201
201
201
201
202
207
211
216
217
221
224
225
229
233
241
248

M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_109_025
M70_109_025
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020

Designation / Type

Supplier

Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-BW-NB80-A105
Inverted Bucket-CL600-SW-NB25-A105
Inverted Bucket-CL600-SW-NB25-A105
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Drawing

Type of Doc

List of Data Sheets & Sectional drawings


Sectional drawing
Data Sheet
Installation, operation and maintenance instruction

Customer Doc. No.


See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 80-L-M-36328
See 80-L-M-36328
See 80-L-M-36328
FY-4C091406-E-0
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
page : 9/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 9 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
12
12

QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFA
QFA
QFA
QFA
QFA
QLB
QLB

02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
10
20
30
40
50
33
33

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
252
260
264
266
268
270
236
250
272
274
276
278
280
282
284
286
288
290
292
310
312
314
316
318
320
322
324
326
328
201
201
201
201
201
201
203

M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_121_040
M70_121_040
M70_121_040
M70_121_040
M70_121_040
M70_122_025
M70_122_025

Designation / Type

Supplier

Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB20-A105N
Y Filter-CL800-NPT-NB40-A105
Y Filter-CL800-NPT-NB40-A105
Y Filter-CL800-NPT-NB40-A105
Y Filter-CL800-NPT-NB40-A105
Y Filter-CL800-NPT-NB40-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
page : 10/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 10 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
12
13
13
13
14
14
14
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB

33
33
33
33
33
33
33
11
11
11
12
12
12
12
12
12
12
12
12
13
21
22
22
22
22
22
22
23
32
32
32
32
32
32
32
32

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
240
201
203
240
201
203
240
201
211
221
201
203
204
206
208
211
215
219
223
201
201
204
205
206
207
215
219
201
201
209
213
217
221
223
226
234

M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025

Designation / Type

Supplier

Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
page : 11/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 11 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
89
89
89
89
89
89
89
89
89
89
89
89
89
80
80
80
80
80

QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLC
QLC
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB

32
32
32
33
33
33
33
34
34
34
34
34
34
34
34
34
02
03
20
20
20
20
20
20
20
20
20
20
20
20
34
32
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
238
242
246
201
205
209
233
201
204
207
231
241
316
321
326
331
001
001
201
203
205
208
209
224
228
231
232
234
236
238
311
248
206
210
212
214

M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025

Designation / Type

Supplier

Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
page : 12/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 12 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
12
12
12
12
13
13
13
13
14

QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

34
34
34
34
34
34
34
34
34
34
35
35
35
35
35
35
35
35
22
36
36
36
36
36
36
36
36
01
01
02
02
01
01
02
02
01

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
216
218
220
22
224
226
228
230
234
238
201
203
205
207
209
211
213
215
208
201
203
205
207
209
211
213
215
201
203
201
203
201
203
201
203
201

M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080

Designation / Type

Supplier

Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-SW-NB25-A105
Y Filter-CL800-BW-NB80-A105
Y Filter-CL800-BW-NB80-A105
Y Filter-CL800-BW-NB80-A105
Y Filter-CL800-BW-NB80-A105
Y Filter-CL800-BW-NB80-A105
Y Filter-CL800-BW-NB80-A105
Y Filter-CL800-BW-NB80-A105
Y Filter-CL800-BW-NB80-A105
Y Filter-CL800-BW-NB80-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
page : 13/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 13 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
14
14
14
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

01
02
02
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
203
201
203
511
512
513
514
521
522
523
524
531
532
533
534
541
542
543
544
551
552
553
554
561
562
563
564
571
572
573
574
581
582
583
584
591

M70_123_080
M70_123_080
M70_123_080
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Designation / Type

Supplier

Y Filter-CL800-BW-NB80-A105
Y Filter-CL800-BW-NB80-A105
Y Filter-CL800-BW-NB80-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 80QFA04AT201
See 80QFA04AT201
See 80QFA04AT201
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
page : 14/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 14 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
592
593
594
601
602
603
604
611
612
613
614
621
622
623
624
631
632
633
634
641
642
643
644
651
652
653
654
661
662
663
664
671
672
673
674
681

M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Designation / Type

Supplier

Bimetalic Thermostatic Trap-CL300-SW-NB20-A105


Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
page : 15/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 15 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
682
683
684
691
692
693
694
701
702
703
704
711
712
713
714
721
722
723
724
731
732
733
734
741
742
743
744
745
746
747
748
749
761
762
763
764

M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Designation / Type

Supplier

Bimetalic Thermostatic Trap-CL300-SW-NB20-A105


Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
page : 16/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 16 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
35
35
35
35
35
35
35
35
35
35

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
765
766
767
768
769
781
782
783
784
785
786
787
791
792
793
794
795
796
797
801
802
803
804
805
806
807
811
821
831
841
851
861
871
812
813
822

M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Designation / Type

Supplier

Bimetalic Thermostatic Trap-CL300-SW-NB20-A105


Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
page : 17/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 17 of 130

Checked and released:


Consortium member : __________

Rev.

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 MM 100
Cust. doc. No. 80-L-M-35635
Revision: A

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

35
35
35
35
35
35
35
35
35
35
35
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
823
832
833
842
843
852
853
862
863
881
882
891
892
901
902
911
912
921
922
931
932
941
942
951
952
961
962
971
972

M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Designation / Type

Supplier

Bimetalic Thermostatic Trap-CL300-SW-NB20-A105


Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105
Bimetalic Thermostatic Trap-CL300-SW-NB20-A105

Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.
Douglas-Italia S.p.A.

Type of Doc

Drawing
Customer Doc. No.
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202
See 14LBA21AA202

page : 18/18

Issued:
Supplier :__________

Checked and released:


Supplier :__________
SHA/80/M/---M70/MM/100 Rev. A Page 18 of 130

Checked and released:


Consortium member : __________

Rev.

15/03/10

A.C

S.G.

A.B.

REV

DATE

PREPARED

CHECKED

APPROVED

FIRST ISSUE

FUS
MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

abcd
Power

Scale: N.A.

SUB CONTRACTOR

Format:

A4

Dougla-Italia
Title:

Project :

IS

SHA

KKS

Doc Type :

Language: E

N/A

FOR

Consortium Participant or Subcontractor Document No. : N/A

abcd

LIST OF DATA SHEET &


DRAWINGS
DRAIN TRAPS

No of sheet: 21

Power Systems
Plant

Sheet:
1 of 21

Alstom document No:

SHA/80/M/--- M70/DL/002

Client Document No. :

80-L-M-36328

SHA/80/M/---M70/MM/100 Rev. A Page 19 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No

14
13
12
14
13
12
14
13
12
14
13
12
14
13
12
14
13
12
14
13
12
14
13
12

LBA
LBA
LBA
LBB
LBB
LBB
MAN
MAN
MAN
LBC
LBC
LBC
LBC
LBC
LBC
LBC
LBC
LBC
LBG
LBG
LBG
LBG
LBG
LBG

21
21
21
21
21
21
10
10
10
15
15
15
30
30
30
90
90
90
05
05
05
15
15
15

AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA

Techno Code

202
202
202
202
202
202
202
202
202
212
212
212
204
204
204
202
202
202
202
202
202
202
202
202

M70_002_025
M70_002_025
M70_002_025
M70_003_025
M70_003_025
M70_003_025
M70_003_025
M70_003_025
M70_003_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_004_025
M70_005_025
M70_005_025
M70_005_025
M70_006_025
M70_006_025
M70_006_025

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
80-L-M-36329
SHA 80 M---M70 DS200
SHA 80M---M70DS002
SHA 80M---M70DS002
SHA 80M---M70DS002
SHA 80M---M70DS003
SHA 80M---M70DS003
SHA 80M---M70DS003
SHA 80M---M70DS003
SHA 80M---M70DS003
SHA 80M---M70DS003
SHA 80M---M70DS004
SHA 80M---M70DS004
SHA 80M---M70DS004
SHA 80M---M70DS004
SHA 80M---M70DS004
SHA 80M---M70DS004
SHA 80M---M70DS004
SHA 80M---M70DS004
SHA 80M---M70DS004
SHA 80M---M70DS005
SHA 80M---M70DS005
SHA 80M---M70DS005
SHA 80M---M70DS006
SHA 80M---M70DS006
SHA 80M---M70DS006

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
A
SHA 80M---M70DD002
B
80-L-M-36259
SHA 80M---M70DD002
B
80-L-M-36259
SHA 80M---M70DD002
B
80-L-M-36259
SHA 80M---M70DD003
B
80-L-M-36260
SHA 80M---M70DD003
B
80-L-M-36260
SHA 80M---M70DD003
B
80-L-M-36260
SHA 80M---M70DD003
B
80-L-M-36260
SHA 80M---M70DD003
B
80-L-M-36260
SHA 80M---M70DD003
B
80-L-M-36260
SHA 80M---M70DD004
B
80-L-M-36261
SHA
80M---M70DD004
B
80-L-M-36261
SHA 80M---M70DD004
B
80-L-M-36261
SHA 80M---M70DD004
B
80-L-M-36261
SHA 80M---M70DD004
B
80-L-M-36261
SHA 80M---M70DD004
B
80-L-M-36261
SHA 80M---M70DD004
B
80-L-M-36261
SHA 80M---M70DD004
B
80-L-M-36261
SHA 80M---M70DD004
B
80-L-M-36261
SHA 80M---M70DD005
B
80-L-M-36262
SHA 80M---M70DD005
B
80-L-M-36262
SHA 80M---M70DD005
B
80-L-M-36262
SHA 80M---M70DD006
A
80-L-M-36263
SHA 80M---M70DD006
A
80-L-M-36263
SHA 80M---M70DD006
A
80-L-M-36263

Rev.
E
E
E
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
B
B
B
A
A
A

1/20
SHA/80/M/---M70/MM/100 Rev. A Page 20 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
14
13
12
14
13
12
14
13
12
14
13
12
14
14
13
13
12
12
80
80
80
80
14
14
14
14
14
14
14
14
14

LBG
LBG
LBG
LBG
LBG
LBG
SCB
SCB
SCB
SCB
SCB
SCB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

30
30
30
60
60
60
20
20
20
20
20
20
33
33
33
33
33
33
33
33
32
32
33
33
33
33
33
33
33
33
33

AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
202
202
202
202
202
202
202
202
202
204
204
204
511
551
511
551
511
551
511
521
511
521
511
512
513
514
515
521
522
523
524

M70_006_025
M70_006_025
M70_006_025
M70_006_025
M70_006_025
M70_006_025
M70_007_025
M70_007_025
M70_007_025
M70_007_025
M70_007_025
M70_007_025
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS006
SHA 80M---M70DS006
SHA 80M---M70DS006
SHA 80M---M70DS006
SHA 80M---M70DS006
SHA 80M---M70DS006
SHA 80M---M70DS007
SHA 80M---M70DS007
SHA 80M---M70DS007
SHA 80M---M70DS007
SHA 80M---M70DS007
SHA 80M---M70DS007
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DD006
A
80-L-M-36263
SHA 80M---M70DD006
A
80-L-M-36263
SHA 80M---M70DD006
A
80-L-M-36263
SHA 80M---M70DD006
A
80-L-M-36263
SHA 80M---M70DD006
A
80-L-M-36263
SHA 80M---M70DD006
A
80-L-M-36263
SHA 80M---M70DD007
A
80-L-M-36264
SHA 80M---M70DD007
A
80-L-M-36264
SHA 80M---M70DD007
A
80-L-M-36264
SHA 80M---M70DD007
A
80-L-M-36264
SHA 80M---M70DD007
A
80-L-M-36264
SHA
80M---M70DD007
A
80-L-M-36264
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B

Rev.
A
A
A
A
A
A
C
C
C
C
C
C
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
2/20

SHA/80/M/---M70/MM/100 Rev. A Page 21 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
14
13
13
13
13
13
13
13
13
13
13
12
12
12
12
12
12
12
12
12
12
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
32
32
32
32

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
525
511
512
513
514
515
521
522
523
524
525
511
512
513
514
515
521
522
523
524
525
511
521
531
532
533
534
541
542
543
544

M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_008_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B

Rev.
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
3/20

SHA/80/M/---M70/MM/100 Rev. A Page 22 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QFA
QFA
QFA
QFA
QFA
QFA
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB

32
32
32
32
04
06
06
08
16
18
01
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
551
552
553
554
205
206
215
205
205
205
205
203
205
208
212
218
222
226
230
234
242
247
251
253
259
261
265
267
269
271
237

M70_008_020
M70_008_020
M70_008_020
M70_008_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS008
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36265
SHA 80M---M70DD008
B
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F

Rev.
A
A
A
A
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
4/20

SHA/80/M/---M70/MM/100 Rev. A Page 23 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
12
12
12
13

QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFA
QFA
QFA
QFA
QFA
QLB
QLB
QLB
QLB

02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
10
20
30
40
50
33
33
33
33

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
240
273
275
277
279
281
283
285
287
289
291
293
311
313
315
317
319
321
323
325
327
329
205
205
205
205
205
202
204
241
202

M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_101_020
M70_102_025
M70_102_025
M70_102_025
M70_102_025
M70_102_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS101
SHA 80M---M70DS102
SHA 80M---M70DS102
SHA 80M---M70DS102
SHA 80M---M70DS102
SHA 80M---M70DS102
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36266
SHA 80M---M70DD101
F
80-L-M-36268
SHA 80M---M70DD102
A
80-L-M-36268
SHA 80M---M70DD102
A
80-L-M-36268
SHA 80M---M70DD102
A
80-L-M-36268
SHA 80M---M70DD102
A
80-L-M-36268
SHA 80M---M70DD102
A
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F

Rev.
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
B
B
B
B
B
F
F
F
F
5/20

SHA/80/M/---M70/MM/100 Rev. A Page 24 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
13
13
14
14
14
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
89
80

QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB

33
33
33
33
33
32
32
32
32
32
32
32
32
32
32
32
33
33
33
33
34
34
34
34
34
34
34
34
34
34
32

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
204
241
202
204
241
203
210
214
218
222
224
227
235
239
243
247
202
206
210
234
202
205
208
232
242
317
322
327
332
312
249

M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA
80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F

Rev.
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
6/20

SHA/80/M/---M70/MM/100 Rev. A Page 25 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB

34
34
34
34
34
34
34
34
34
34
34
34
34
34
35
35
35
35
35
35
35
35
36
36
36
36
36
36
36
36
11

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
209
211
213
215
217
219
221
223
225
227
229
235
239
240
202
204
206
208
210
212
214
216
202
204
206
208
210
212
214
216
202

M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_103_025
M70_105_025

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS103
SHA 80M---M70DS105

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA
80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36267
SHA 80M---M70DD103
F
80-L-M-36269
SHA 80M---M70DD105
A

Rev.
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
C
7/20

SHA/80/M/---M70/MM/100 Rev. A Page 26 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
89
89
89
89
89
89
89
89
89
89
89

QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB

11
11
12
12
12
12
12
12
12
12
12
13
21
22
22
22
22
22
22
23
20
20
20
20
20
20
20
20
20
20
20

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
212
222
110
202
205
207
209
212
216
220
224
202
202
209
210
211
212
216
220
202
202
206
211
213
214
221
225
229
233
235
237

M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_105_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_106_025

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS105
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36269
SHA 80M---M70DD105
A
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D

Rev.
C
C
C
C
C
C
C
C
C
C
C
C
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
8/20

SHA/80/M/---M70/MM/100 Rev. A Page 27 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
89
80
80
80
12
12
12
12
13
13
13
13
14
14
14
14
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLB
QLB
QLB
QLB
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QFA
QFA
QFA
QFA
QFA
QFA
QFB
QFB
QFB
QFB
QFB
QFB
QFB

20
22
22
22
01
01
02
02
01
01
02
02
01
01
02
02
02
03
04
06
06
08
16
18
01
02
02
02
02
02
02

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
239
217
218
213
202
204
202
204
202
204
202
204
202
204
202
204
002
002
201
202
211
201
201
201
201
201
202
207
211
216
217

M70_106_025
M70_106_025
M70_106_025
M70_106_025
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_108_080
M70_109_025
M70_109_025
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS106
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS108
SHA 80M---M70DS109
SHA 80M---M70DS109
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36270
SHA 80M---M70DD106
D
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36271
SHA 80M---M70DD108
A
80-L-M-36272
SHA 80M---M70DD109
A
80-L-M-36272
SHA 80M---M70DD109
A
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA
80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F

Rev.
A
A
A
A
E
E
E
E
E
E
E
E
E
E
E
E
A
A
F
F
F
F
F
F
F
F
F
F
F
F
F
9/20

SHA/80/M/---M70/MM/100 Rev. A Page 28 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB
QFB

02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
221
224
225
229
233
241
248
252
260
264
266
268
270
236
250
272
274
276
278
280
282
284
286
288
290
292
310
312
314
316
318

M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA
80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F

Rev.
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
10/20

SHA/80/M/---M70/MM/100 Rev. A Page 29 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
12
12
12
13
13
13
14
14
14
80
80
80
80
80
80
80
80
80
80
80
80

QFB
QFB
QFB
QFB
QFB
QFA
QFA
QFA
QFA
QFA
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB

02
02
02
02
02
10
20
30
40
50
33
33
33
33
33
33
33
33
33
11
11
11
12
12
12
12
12
12
12
12
12

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
320
322
324
326
328
201
201
201
201
201
201
203
240
201
203
240
201
203
240
201
211
221
201
203
204
206
208
211
215
219
223

M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_120_020
M70_121_040
M70_121_040
M70_121_040
M70_121_040
M70_121_040
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS120
SHA 80M---M70DS121
SHA 80M---M70DS121
SHA 80M---M70DS121
SHA 80M---M70DS121
SHA 80M---M70DS121
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36273
SHA 80M---M70DD120
F
80-L-M-36275
SHA 80M---M70DD121
A
80-L-M-36275
SHA 80M---M70DD121
A
80-L-M-36275
SHA 80M---M70DD121
A
80-L-M-36275
SHA 80M---M70DD121
A
80-L-M-36275
SHA 80M---M70DD121
A
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA
80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F

Rev.
F
F
F
F
F
A
A
A
A
A
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
11/20

SHA/80/M/---M70/MM/100 Rev. A Page 30 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB

13
21
22
22
22
22
22
22
23
32
32
32
32
32
32
32
32
32
32
32
33
33
33
33
34
34
34
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
201
201
204
205
206
207
215
219
201
201
209
213
217
221
223
226
234
238
242
246
201
205
209
233
201
204
207
231
241
316
321

M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA
80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F

Rev.
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
12/20

SHA/80/M/---M70/MM/100 Rev. A Page 31 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
89
89
89
89
89
89
89
89
89
89
89
89
89
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLB
QLB
QLC
QLC
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB

34
34
02
03
20
20
20
20
20
20
20
20
20
20
20
20
34
32
34
34
34
34
34
34
34
34
34
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
326
331
001
001
201
203
205
208
209
224
228
231
232
234
236
238
311
248
206
210
212
214
216
218
220
22
224
226
228
230
234

M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA
80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F

Rev.
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
13/20

SHA/80/M/---M70/MM/100 Rev. A Page 32 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
12
12
12
12
13
13
13
13
14
14
14
14
80

QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLB
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

34
35
35
35
35
35
35
35
35
22
36
36
36
36
36
36
36
36
01
01
02
02
01
01
02
02
01
01
02
02
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
238
201
203
205
207
209
211
213
215
208
201
203
205
207
209
211
213
215
201
203
201
203
201
203
201
203
201
203
201
203
511

M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_122_025
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_123_080
M70_124_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS122
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS123
SHA 80M---M70DS124

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36276
SHA 80M---M70DD122
F
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36277
SHA 80M---M70DD123
A
80-L-M-36278
SHA 80M---M70DD124
C

Rev.
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
E
E
E
E
E
E
E
E
E
E
E
E
A
14/20

SHA/80/M/---M70/MM/100 Rev. A Page 33 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
512
513
514
521
522
523
524
531
532
533
534
541
542
543
544
551
552
553
554
561
562
563
564
571
572
573
574
581
582
583
584

M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C

Rev.
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
15/20

SHA/80/M/---M70/MM/100 Rev. A Page 34 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
591
592
593
594
601
602
603
604
611
612
613
614
621
622
623
624
631
632
633
634
641
642
643
644
651
652
653
654
661
662
663

M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C

Rev.
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
16/20

SHA/80/M/---M70/MM/100 Rev. A Page 35 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
664
671
672
673
674
681
682
683
684
691
692
693
694
701
702
703
704
711
712
713
714
721
722
723
724
731
732
733
734
741
742

M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C

Rev.
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
17/20

SHA/80/M/---M70/MM/100 Rev. A Page 36 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
743
744
745
746
747
748
749
761
762
763
764
765
766
767
768
769
781
782
783
784
785
786
787
791
792
793
794
795
796
797
801

M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C

Rev.
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
18/20

SHA/80/M/---M70/MM/100 Rev. A Page 37 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

34
34
34
34
34
34
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
36
36
36
36

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
802
803
804
805
806
807
811
821
831
841
851
861
871
812
813
822
823
832
833
842
843
852
853
862
863
881
882
891
892
901
902

M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C

Rev.
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
19/20

SHA/80/M/---M70/MM/100 Rev. A Page 38 of 130

LIST OF
DATA SHEETS and DRAWINGS

KKS No
80
80
80
80
80
80
80
80
80
80
80
80
80
80

QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC
QLC

36
36
36
36
36
36
36
36
36
36
36
36
36
36

AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT
AT

Techno Code
911
912
921
922
931
932
941
942
951
952
961
962
971
972

M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020
M70_124_020

Data Sheet
Customer Doc. No. ALSTOM Doc. No.
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124
SHA 80M---M70DS124

Shoaiba Steam Power Plant


Stage III
SHA 80 M--- M70 DL 002
Cust. doc. No. 80-L-M-36328
Revision: A

Drawing
Rev. Customer Doc. No. ALSTOM Doc. No.
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C
80-L-M-36278
SHA 80M---M70DD124
C

Rev.
A
A
A
A
A
A
A
A
A
A
A
A
A
A

20/20
SHA/80/M/---M70/MM/100 Rev. A Page 39 of 130

15/03/10

A.C

S.G.

A.B.

REV

DATE

PREPARED

CHECKED

APPROVED

FIRST ISSUE

FUS
MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

abcd
Power

Scale: N.A.

SUB CONTRACTOR

Format:

A4
Title:

DATA SHEETS
Project :

IS

SHA

KKS

Doc Type :

Consortium Participant or Subcontractor Document No. : N/A

abcd
Alstom document No:

SHA/80/M/--- M70/DS/200

OF

N/A

Language: E

DRAIN TRAPS
No of sheet:

Power Systems
Plant

Sheet:

Client Document No. :

80-L-M-36329

SHA/80/M/---M70/MM/100 Rev. A Page 40 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Functional code(s)

Drain of main steam

Unit: 12-13-14

SAUDI ELECTRICITY COMPANY


3x1

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
12-13-14 LBA 21 AA 202

8
9

ND (nominal diameter)

mm

10

PN (nominal pressure) / series

11

Type

12

Location

25
2500 LBS
THERMOSTATIC

indoor outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

bar abs.

CONDENSATE
167.7

17

Nominal downstream pressure

bar abs.

ATMOSPHERE

18

Maximum pressure

bar abs.

193

19

Nominal temperature

538

20

Maximum temperature

547

21

Specific weight

22

Steam dryness fraction

23

Flow

24

Pressure drop / Design D P

kg/dm
%
Kg/h
bar

25 / 25

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

Yes

34

Filter incorporated

Yes / No

Yes

35

Body drain

Yes / No

No

36
MATERIAL

37
38

Body-bonnet

39

Seat

A 182 F22

40

Obturator

41

Obturator coating

42

Stem or axis

Nitronic+stellite
Nitronic 60

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-002-025

Issue
Date
Author
Checked by
Approved by

S.S.
AISI 304
kg

A
05/12/08
Douglas-Italia

SHA 80 M --- M70 DD 002

B
18/03/09
Douglas-Italia

N SHA 80 M --- M70 DS 002

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 41 of 130

abcd
DATA SHEET
DRAIN TRAPS
Unit: 12-13-14

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

SAUDI ELECTRICITY COMPANY


3x2

FUNCTIONAL CODE
MANUFACTURER

IDENTIFICATION
Functional code(s)

12-13-14 LBB 21 AA 202

12-13-14 MAN 10 AA 202

Reheater steam

ND (nominal diameter)

10

Mfr's REFERENCE

mm

PN (nominal pressure) / series

11

Type

12

Location

25
2500 LBS
THERMOSTATIC

indoor outdoor

Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

bar abs.

CONDENSATE
39.1

17

Nominal downstream pressure

bar abs.

ATMOSPHERE

18

Maximum pressure

bar abs.

50

19

Nominal temperature

538

546

20

Maximum temperature

21

Specific weight

kg/dm

22

Steam dryness fraction

23

Flow

24

Pressure drop / Design D P

%
Kg/h
bar

25 / 25

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

Yes

34

Filter incorporated

Yes / No

Yes

35

Body drain

Yes / No

No

36
MATERIAL

37
38

Body-bonnet

39

Seat

40

Obturator

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-003-025

Issue
Date
Author
Checked by
Approved by

A 182 F22
Nitronic 50 + stell
Nitronic 60
Nitronic 60
S.S.
AISI 304
kg

A
05/12/08
Douglas-Italia

SHA 80 M --- M70 DD 003

B
18/03/09
Douglas-Italia

N SHA 80 M --- M70 DS 003

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 42 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Functional code(s)

Cold reheat line

Unit: 12-13-14

SAUDI ELECTRICITY COMPANY


3x3

FUNCTIONAL CODE
MANUFACTURER

IDENTIFICATION
12-13-14 LBC 15 AA 212
12-13-14 LBC 30 AA 204

8
9

Mfr's REFERENCE

12-13-14 LBC 90 AA 202


ND (nominal diameter)

mm

10

PN (nominal pressure) / series

11

Type

12

Location

25
600 LBS
THERMOSTATIC

indoor outdoor

Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

bar abs.

CONDENSATE
42.7

17

Nominal downstream pressure

bar abs.

ATMOSPHERE

18

Maximum pressure

bar abs.

54

19

Nominal temperature

335

20

Maximum temperature

380

21

Specific weight

22

Steam dryness fraction

23

Flow

24

Pressure drop / Design D P

kg/dm
%
Kg/h
bar

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

25 / 25

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

Yes

34

Filter incorporated

Yes / No

Yes (0.4 mm)

35

Body drain

Yes / No

No

36
MATERIAL

37
38

Body-bonnet

39

Seat

A 105
SS

40

Obturator

SS

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-004-025

Issue
Date
Author
Checked by
Approved by

316L
kg

A
05/12/08
Douglas-Italia

SHA 80 M --- M70 DD 004

B
18/03/09
Douglas-Italia

N SHA 80 M --- M70 DS 004

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 43 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Functional code(s)

Auxiliary steam from boiler

Unit: 12-13-14

SAUDI ELECTRICITY COMPANY


3x1

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
12-13-14 LBG 05 AA 202

8
9

ND (nominal diameter)

mm

10

PN (nominal pressure) / series

11

Type

12

Location

25
2500 LBS
THERMOSTATIC

indoor outdoor

Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

bar abs.

CONDENSATE
186

17

Nominal downstream pressure

bar abs.

ATMOSPHERE

18

Maximum pressure

bar abs.

208.16

19

Nominal temperature

446

20

Maximum temperature

457

21

Specific weight

22

Steam dryness fraction

kg/dm

23

Flow

24

Pressure drop / Design D P

%
Kg/h
bar

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

25 / 25

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

Yes

34

Filter incorporated

Yes / No

Yes

35

Body drain

Yes / No

No

36
MATERIAL

37
38

Body-bonnet

39

Seat

40

Obturator

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-005-025

Issue
Date
Author
Checked by
Approved by

A 182 F22
Nitronic + stellite
Nitronic 60

S.S.
S.S. 304 (0.4mm)
kg

A
05/12/08
Douglas-

SHA 80 M --- M70 DD 005

B
18/03/09
Douglas-

N SHA 80 M --- M70 DS 005

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 44 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project : SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Unit : 12-13-14

SAUDI ELECTRICITY COMPANY


3x3

FUNCTIONAL CODE
MANUFACTURER

IDENTIFICATION
Functional code(s)

12-1314 LBG30 AA 202

12-1314 LBG60 AA202

8
9

Mfr's REFERENCE

12-1314 LBG15 AA202


ND (nominal diameter)

mm

10

PN (nominal pressure) / series

11

Type

12

Location

25
600 LBS
THERMOSTATIC

indoor outdoor

Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

bar abs.

CONDENSATE
15

17

Nominal downstream pressure

bar abs.

ATMOSPHERE

18

Maximum pressure

bar abs.

21

19

Nominal temperature

250

20

Maximum temperature

300

21

Specific weight

22

Steam dryness fraction

23

Flow

24

Pressure drop / Design D P

kg/dm
%
Kg/h
bar

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

25 / 25

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

Yes

34

Filter incorporated

Yes / No

Yes

35

Body drain

Yes / No

No

36
MATERIAL

37
38

Body-bonnet

39

Seat

40

Obturator

A 105

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-006-025

Issue
Date
Author
Checked by
Approved by

SS 304 (0.4mm)
kg
SHA 80 M --- M70 DD 006

A
05/12/08
Douglas-Italia

N SHA 80 M --- M70 DS 006

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 45 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


CLIENT
QUANTITY
INSTALLATION

Unit: 12-13-14

1
2
3
4
5
6

SAUDI ELECTRICITY COMPANY


3x2
HORIZONTAL

FUNCTIONAL CODE

Functional code(s)

12-13-14 SCB 20 AA 202

Compressed air

12-13-14 SCB 20 AA 204

MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION

8
9

ND (nominal diameter)

mm

10

PN (nominal pressure) / series

11

Type

12

Location

25
150 LBS
FLOAT

indoor outdoor

Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

bar abs.

AIR
9.2

17

Nominal downstream pressure

bar abs.

ATMOSPHERE

18

Maximum pressure

bar abs.

12

19

Nominal temperature

40

20

Maximum temperature

80

21

Specific weight

22

Steam dryness fraction

kg/dm

23

Flow

24

Pressure drop / Design D P

%
Kg/h
bar

25 / 25

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

FLANGE 150 RF

31

Outlet connection

FLANGE 150 RF

32

Manufacture

33

Obturator incorporated

Yes / No

34

Filter incorporated

Yes / No

No

35

Body drain

Yes / No

No

Yes

36
MATERIAL

37
38

Body-bonnet

39

Seat

A 216 WCB
AISI 316

40

Obturator

AISI 316

41

Obturator coating

AISI 316

42

Stem or axis

AISI 316

43

Float

AISI 316

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-007-025

Issue
Date
Author
Checked by
Approved by

No
kg
SHA 80 M --- M70 DD 007

A
05/12/08
Douglas-Italia

N SHA 80 M --- M70 DS 007

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 46 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Unit: 12-13-14

SAUDI ELECTRICITY COMPANY


54

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
Functional code(s)

See Attachment A-008

7
8

Reheater steam

ND (nominal diameter)

10

mm

PN (nominal pressure) / series

11

Type

12

Location

20
300,
Bimetallic Thermostatic Steam Trap with Integral Strainer

indoor outdoor

Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

Steam/Condensate
bar abs.

17

Nominal downstream pressure

bar abs.

18

Maximum pressure

bar abs.

19

Nominal temperature

20

Maximum temperature

21

Specific weight

22

Steam dryness fraction

23

Flow

24

Pressure drop / Design D P

50

C
C

390

kg/dm
%
Kg/h
bar

20 / 20

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

Yes

34

Filter incorporated

Yes / No

Yes

35

Body drain

Yes / No

No

36
MATERIAL

37
38

Body-bonnet

39

Seat

40

Obturator

A 105

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-

Issue
Date
Author
Checked by
Approved by

S.S.
AISI 316
kg

A
19/06/09
Douglas-Italia

SHA 80 M --- M70 DD 008

B
17/09/09

Douglas-Italia

N SHA 80 M --- M70 DS 008

11DS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 47 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project : SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Functional code(s)

Compressed air

Unit : 80

SAUDI ELECTRICITY COMPANY


27, 26, 39, 49

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
For functional code see the Valve List

8
9
10

ND (nominal diameter)

mm

PN (nominal pressure) / series

11

Type

12

Location

20
150 LBS
FLOAT

Indoor/outdoor

Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

bar abs.

AIR
9.2

17

Nominal downstream pressure

bar abs.

ATMOSPHERE

18

Maximum pressure

bar abs.

12

19

Nominal temperature

40

20

Maximum temperature

80

21

Specific weight

22

Steam dryness fraction

kg/dm

23

Flow

24

Pressure drop / Design D P

%
Kg/h

360

bar

20 / 20

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

NPT female

31

Outlet connection

NPT female

32

Manufacture

33

Obturator incorporated

Yes / No

34

Filter incorporated

Yes / No

NO

35

Body drain

Yes / No

NO

YES

36
MATERIAL

37
38

Body- Bonnet

39

Seat

A 216 WCB

40

Obturator

41

Obturator coating

42

Stem or axis

Hardened alloy
AISI 316

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS : Techno Code M70_101_020

Issue
Date
Author
Checked by
Approved by

NA
kg

C
18/06/09
Douglas

SHA 80 M --- M70 DD 101

D
30/09/09
Italia

E
05/10/09
Douglas

F
08/02/10
Italia

N SHA 80 M --- M70 DS 101

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 48 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Functional code(s)

Drain air receivers

Unit: 80

SAUDI ELECTRICITY COMPANY


5

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
. 80-QFA10AT205 , 80-QFA20AT205 , 80-QFA30AT205,80-QFA40AT205,

80-QFA50AT205

8
9

ND (nominal diameter)

mm

10

PN (nominal pressure) / series

11

Type

12

Location

25
150 LBS
FLOAT

indoor/outdoor

Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

bar abs.

AIR
9.2

17

Nominal downstream pressure

bar abs.

ATMOSPHERE

18

Maximum pressure

bar abs.

12

19

Nominal temperature

40

20

Maximum temperature

80

21

Specific weight

22

Steam dryness fraction

kg/dm

23

Flow

24

Pressure drop / Design D P

%
Kg/h

360

bar

25 / 25

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

NPT female

31

Outlet connection

NPT female

32

Manufacture

33

Obturator incorporated

Yes / No

34

Filter incorporated

Yes / No

NO

35

Body drain

Yes / No

NO

YES

36
MATERIAL

37
38

Body - Bonnet

39

Seat

40

Obturator

A 216 WCB
Hardened alloy

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS : Techno Code M70_102_025

Issue
Date
Author
Checked by
Approved by

NA
kg
SHA 80 M --- M70 DD 102

A
05/12/08
DOUGLAS

N SHA 80 M --- M70 DS 102

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 49 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Functional code(s)

Low pressure auxiliary steam

Unit: 12-13-14, 80

SAUDI ELECTRICITY COMPANY


39, 57, 65

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
For functional code see the attach Valve List

8
9

ND (nominal diameter)

mm

10

PN (nominal pressure) / series

11

Type

12

Location

25
300 LBS

Inverted bucket
indoor outdoor

Inverted bucket
Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

bar abs.

CONDENSATE

17

Nominal downstream pressure

bar abs.

ATMOSPHERE

18

Maximum pressure

bar abs.

13

19

Nominal temperature

20

Maximum temperature

21

Specific weight

22

Steam dryness fraction

23

Flow

24

Pressure drop / Design D P

C
C

230

kg/dm
%
Kg/h

410

bar

25 / 25

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

34

Filter incorporated

Yes / No

No

35

Body drain

Yes / No

No

Yes

36
MATERIAL

37

A 105
(Internal part SS)

38
39

Body - Bonnet
Seat

40

Obturator

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

AISI 316

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno Code M70_103_025

Issue
Date
Author
Checked by
Approved by

kg

C
18/06/09
Douglas

SHA 80 M --- M70 DD 103

D
30/09/09
Douglas

E
05/10/09
Douglas

F
08/02/10
Douglas
N SHA 80 M --- M70 DS 103

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 50 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Functional code(s)

Sliding operating pressure steam line

Unit: 80

SAUDI ELECTRICITY COMPANY


16

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
For functional code see the attach sheet no. A-105

8
9
10

ND (nominal diameter)

mm

PN (nominal pressure) / series

11

Type

12

Location

25
600 LBS

Inverted bucket
indoor outdoor

Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

CONDENSATE
bar abs.

17

Nominal downstream pressure

bar abs.

18

Maximum pressure

bar abs.

16

19

Nominal temperature

20

Maximum temperature

21

Specific weight

22

Steam dryness fraction

23

Flow required / maxi

24

Pressure drop / Design D P

390

kg/dm
%
Kg/h

360/1200 Max.

bar

25 / 25

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

34

Filter incorporated

Yes / No

No

35

Body drain

Yes / No

No

Yes

36
MATERIAL

37
38

Body-Bonnet

39

Seat

40

Obturator

A 105 / A 105

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-105-025

Issue
Date
Author
Checked by
Approved by

kg
SHA 80 M --- M70 DD 105

A
05/12/08

Douglas
N SHA 80 M --- M70 DS 105

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 51 of 130

abcd
Attach sheet no. A-105
80-QLB12AT202,80-QLB12AT205,80-QLB12AT207,80-QLB12AT209,80-QLB13AT202,80-QLB12AT110,80-QLB12AT212,80-QLB12AT216
80-QLB12AT220,80-QLB12AT224,80-QLB12AT228,80-QLB12AT232,80-QLB12AT236,80-QLB11AT202,80-QLB11ATAT212,80-QLB11AT222

MDS FT 355 A

Folio 2/1
SHA/80/M/---M70/MM/100 Rev. A Page 52 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Functional code(s)

Medium pressure auxiliary steam

Unit: 80,89

SAUDI ELECTRICITY COMPANY


25 ,

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
For functional code see the attach sheet no. A-106

8
9

ND (nominal diameter)

mm

10

PN (nominal pressure) / series

11

Type

12

Location

25
300 LBS

Inverted bucket
indoor outdoor

Inverted bucket
Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

bar abs.

CONDENSATE

17

Nominal downstream pressure

bar abs.

ATMOSPHERE

18

Maximum pressure

bar abs.

21

19

Nominal temperature

20

Maximum temperature

21

Specific weight

22

Steam dryness fraction

23

Flow required / maxi

24

Pressure drop / Design D P

C
C

300

kg/dm
%
Kg/h

300/380Max.

bar

25 / 25

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

34

Filter incorporated

Yes / No

No

35

Body drain

Yes / No

No

Yes

36
MATERIAL

37
38
39

Body Bonnet
Seat

40

Obturator

A 105
(Internal part SS)
AISI 316

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-106-025

Issue
Date
Author
Checked by
Approved by

kg

A
05/12/08

Douglas

SHA 80 M --- M70 DD 106

B
18/03/09
Douglas

C
17/09/09
Douglas

D
05/10/09
Douglas
N SHA 80 M --- M70 DS 106

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 53 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project : SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Functional code(s)

HFO forwarding heater

Unit : 12-13-14

SAUDI ELECTRICITY COMPANY


12

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
For functional code see the attach sheet no. A-108

8
9

ND (nominal diameter)

mm

10

PN (nominal pressure) / series

11

Type

12

Location

80
150 LBS

Inverted bucket
indoor outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

CONDENSATE
bar abs.

17

Nominal downstream pressure

bar abs.

18

Maximum pressure

bar abs.

13

19

Nominal temperature

20

Maximum temperature

21

Specific weight

22

Steam dryness fraction

23

Flow required / maxi

24

Pressure drop / Design D P

230

kg/dm
%
Kg/h

720

bar

80 / 80

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

B.W.

31

Outlet connection

B.W.

32

Manufacture

33

Obturator incorporated

Yes / No

34

Filter incorporated

Yes / No

No

35

Body drain

Yes / No

No

Yes

36
MATERIAL

37
38

Body - Bonnet

39

Seat

40

Obturator

A 105 / A 105
ASI410

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-108-050

Issue
Date
Author
Checked by
Approved by

110 kg
SHA 80 M --- M70 DD 108

A
05/12/08

Douglas
N SHA 80 M --- M70 DS 108

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 54 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Functional code(s)

Slop tank

Unit: 80

SAUDI ELECTRICITY COMPANY


2

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
80-QLC02AT002,80-QLC03AT002

8
9

ND (nominal diameter)

mm

10

PN (nominal pressure) / series

11

Type

12

Location

25
300 LBS

Inverted bucket
indoor outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

CONDENSATE
bar abs.

17

Nominal downstream pressure

bar abs.

18

Maximum pressure

bar abs.

13

19

Nominal temperature

20

Maximum temperature

21

Specific weight

22

Steam dryness fraction

23

Flow required / maxi

24

Pressure drop / Design D P

230

kg/dm
%
Kg/h

360

bar

25 / 25

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

34

Filter incorporated

Yes / No

NO

35

Body drain

Yes / No

NO

YES

36
MATERIAL

37
38

Body - Bonnet

39

Seat

40

Obturator

AISI 304 / A 105

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-109-025

Issue
Date
Author
Checked by
Approved by

kg
SHA 80 M --- M70 DD 109

A
05/12/08

Douglas
N SHA 80 M --- M70 DS 109

MDS FT 355 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 55 of 130

abcd
DATA SHEET
FILTER

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
44
45
46
47
48
49
50
51
52
53
54
55

CLIENT

Unit: 80

SAUDI ELECTRICITY COMPANY

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

Quantity
27, 39, 49
Functional code(s)
For functional code see the attach Valve List
Destination
Air compressed lines
Type
Y filter
Series No
800 LBS
Installation
indoor / outdoor
Outdoor
Definition of the estimated operating conditions:
1
2
OPERATING CHARACTERISTICS
Nature of fluid
Air compressed
Temperature
C
80
Flow rate
m/hr
Filter inlet pressure
bar abs.
12
Porosity

400
Clean filter head loss
bar
Fouled filter head loss
bar
Filtering surface
m
Passage surface
m
Passage surface to nozzle surface ratio
Mesh dimensions
mm
Filter test pressure
bar gage
Allowable max. Differential pressure through sieve
bar
CONSTRUCTION
Construction standard / test code
B16.34
/
SHELL-COVER
A 105
Inlet / outlet pipes nominal diameter
mm
20 / 20
/
Inlet / outlet connection type
NPTF / NPTF
/
Material
A 105
Coating
YES
Vent nominal diameter
mm
Drain nominal diameter
mm
FILTERING ELEMENTS
Number
MATERIAL
Supporting sheet
Sieve
S.S.
Seals
316 GRAPHITE
Vent / drain valve
Yes
No
Fouling indicator
Yes
No
Hydraulic seal
Yes
No
Support / fixation lugs
Yes
No
WEIGHTS - OVERALL DIMENSIONS
Drawing No
SHA 80M---M70DD120
Dry weight
kg
Flooded weight
kg
QUALITY CONTROL PLAN OR CONTROL CLASS

/
/
/

REMARKS: Techno code M70-120-020

Issue
Date
Author
Checked by
Approved by

C
18/06/09
Douglas

D
30/09/09
Douglas

E
05/10/09
Douglas

F
08/02/10
Douglas
N SHA 80M---M70DS120

MDS FT 356 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 56 of 130

abcd
DATA SHEET
FILTER

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
56

CLIENT

Unit: 80

SAUDI ELECTRICITY COMPANY

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

4
Quantity
Functional code(s)
For functional code see the attach sheet no. A-121
Destination
Air compressed lines
Type
Y filter
Series No
800 LBS
Installation
indoor / outdoor
Outdoor
Definition of the estimated operating conditions:
1
2
OPERATING CHARACTERISTICS
Nature of fluid
Air compressed
Temperature
C
80
Flow rate
m/hr
Filter inlet pressure
bar abs.
12
Porosity

400
Clean filter head loss
bar
Fouled filter head loss
bar
Filtering surface
m
Passage surface
m
Passage surface to nozzle surface ratio
Mesh dimensions
mm
Filter test pressure
bar gage
Allowable max. Differential pressure through sieve
bar
CONSTRUCTION
Construction standard / test code
B16.34
/
SHELL-COVER
Inlet / outlet pipes nominal diameter
mm
40 / 40
/
Inlet / outlet connection type
NPTF / NPTF
/
Material
A 105
Coating
YES
Vent nominal diameter
mm
Drain nominal diameter
mm
FILTERING ELEMENTS
Number
1
MATERIAL
Supporting sheet
Sieve
S.S.
Seals
316 GRAPHITE
Vent / drain valve
Yes
Fouling indicator
Yes
Hydraulic seal
Yes
Support / fixation lugs
Yes
WEIGHTS - OVERALL DIMENSIONS
Drawing No
Dry weight
Flooded weight
QUALITY CONTROL PLAN OR CONTROL CLASS

/
/
/

No
No
No
No
SHA 80M---M70DD121
kg
kg

REMARKS: Techno code M70-120-040

Issue
Date
Author
Checked by
Approved by

A
05/12/08

Douglas
N SHA 80M---M70DS121

At

MDS FT 356 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 57 of 130

abcd
DATA SHEET
FILTER

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
56

CLIENT

Unit: 12-13-14,80,89

SAUDI ELECTRICITY COMPANY

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

Quantity
82 , 93, 101
Functional code(s)
For functional code see the attach Valve List
Destination
Steam lines
Type
Y filter
Series No
800 LBS
Installation
indoor / outdoor
Outdoor
Definition of the estimated operating conditions:
1
2
OPERATING CHARACTERISTICS
Nature of fluid
Steam/condensate
Temperature
C
230 / 390
Flow rate
m/hr
Filter inlet pressure
bar abs.
13 / 21
Porosity

400
Clean filter head loss
bar
Fouled filter head loss
bar
Filtering surface
m
Passage surface
m
Passage surface to nozzle surface ratio
Mesh dimensions
mm
Filter test pressure
bar gage
Allowable max. Differential pressure through sieve
bar
CONSTRUCTION
Construction standard / test code
B16.34
/
SHELL-COVER
Inlet / outlet pipes nominal diameter
mm
25 / 25
/
Inlet / outlet connection type
SW / SW
/
Material
A 105
Coating
YES
Vent nominal diameter
mm
Drain nominal diameter
mm
FILTERING ELEMENTS
Number
1
MATERIAL
Supporting sheet
Sieve
S.S.
Seals
316 GRAPHITE
Vent / drain valve
Yes
Fouling indicator
Yes
Hydraulic seal
Yes
Support / fixation lugs
Yes
WEIGHTS - OVERALL DIMENSIONS
Drawing No
Dry weight
Flooded weight
QUALITY CONTROL PLAN OR CONTROL CLASS

/
/
/

No
No
No
No
SHA 80M---M70DD122
kg
kg

REMARKS: Techno code M70-122-025

Issue
Date
Author
Checked by
Approved by

C
30/09/09
Douglas

D
05/10/09
Douglas

E
15/10/09
Douglas

F
08/02/10
Douglas
N SHA 80M---M70DS122

MDS FT 356 A

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 58 of 130

abcd
DATA SHEET
FILTER

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
56

CLIENT

Unit: 12-13-14

SAUDI ELECTRICITY COMPANY

FUNCTIONAL CODE
MANUFACTURER

Quantity
Functional code(s)
Destination
Type
Series No
Installation
indoor / outdoor
Definition of the estimated operating conditions:
1
2
OPERATING CHARACTERISTICS
Nature of fluid
Temperature
C
Flow rate
m/hr
Filter inlet pressure
bar abs.
Porosity

Clean filter head loss


bar
Fouled filter head loss
bar
Filtering surface
m
Passage surface
m
Passage surface to nozzle surface ratio
Mesh dimensions
mm
Filter test pressure
bar gage
Allowable max. Differential pressure through sieve
bar
CONSTRUCTION
Construction standard / test code
SHELL-COVER
Inlet / outlet pipes nominal diameter
mm
Inlet / outlet connection type
Material
Coating
Vent nominal diameter
mm
Drain nominal diameter
mm
FILTERING ELEMENTS
Number
MATERIAL
Supporting sheet
Sieve
Seals
Vent / drain valve
Yes
Fouling indicator
Yes
Hydraulic seal
Yes
Support / fixation lugs
Yes
WEIGHTS - OVERALL DIMENSIONS
Drawing No
Dry weight
Flooded weight
QUALITY CONTROL PLAN OR CONTROL CLASS

Mfr's REFERENCE

12
For functional code see the attach sheet no. A-123
Steam lines
Y
800 LBS
Outdoor

Steam /Condensate
230
13
400

B16.34

80 / 80
BW/BW
A 105
YES

/
/

/
/

1
S.S.
S.S.
316 GRAPHITE

No
No
No
No
SHA 80M---M70DD123
kg
kg

REMARKS: Techno code M70-123-080

Issue
Date
Author
Checked by
Approved by

A
05/12/08

Douglas
A RaO
YKG

N SHA 80M---M70DS123

MDS FT 356 A

Folio 1/2
SHA/80/M/---M70/MM/100 Rev. A Page 59 of 130

abcd
Attach sheet no. A-123

12-QLC01AT201,13QLC01AT201,14-QLC01AT201,12-QLC01AT203,13-QLC01AT203,14-QLC01AT203
12QLC02AT201,13QLC02AT201,14QLC02AT201,12QLC02AT203,13QLC02AT203,14QLC02AT203

MDS FT 356 A

Folio 2/2
SHA/80/M/---M70/MM/100 Rev. A Page 60 of 130

abcd
DATA SHEET
DRAIN TRAPS

Power Turbo-Systems
Plants

Project: SHOAIBA III


1
2
3
4
5
6

CLIENT
QUANTITY
INSTALLATION

Unit: 12-13-14

SAUDI ELECTRICITY COMPANY


138, 170

FUNCTIONAL CODE
MANUFACTURER

Mfr's REFERENCE

IDENTIFICATION
Functional code(s)

See Attached Valve list

7
8

Reheater steam

ND (nominal diameter)

10

mm

PN (nominal pressure) / series

11

Type

12

Location

20
300,
Bimetallic Thermostatic Steam Trap with Integral Strainer

indoor outdoor

Outdoor

13
OPERATING CHARACTERISTICS (DIMENSIONING)

14
15

Nature of fluid

16

Nominal upstream pressure

Steam/Condensate
bar abs.

17

Nominal downstream pressure

bar abs.

18

Maximum pressure

bar abs.

19

Nominal temperature

20

Maximum temperature

21

Specific weight

22

Steam dryness fraction

23

Flow

24

Pressure drop / Design D P

50

C
C

390

kg/dm
%
Kg/h
bar

20 / 20

25
26

CONSTRUCTION

27

BODY - BONNET - SEAT - OBTURATOR

28

Inlet / outlet ND

mm

29

Seat orifice

mm

30

Inlet connection

S.W.

31

Outlet connection

S.W.

32

Manufacture

33

Obturator incorporated

Yes / No

Yes

34

Filter incorporated

Yes / No

Yes

35

Body drain

Yes / No

No

36
MATERIAL

37
38

Body-bonnet

39

Seat

40

Obturator

A 105

41

Obturator coating

42

Stem or axis

43

Float

44

Thermostatic element

45

Filter

47

WEIGHT

49

DRAWINGS - NOTICES

50
51
52

REMARKS: Techno code M70-

Issue
Date
Author
Checked by
Approved by

S.S.
AISI 316
kg

A
19/06/09

Douglas

SHA 80 M --- M70 DD 124

B
30/09/09
Douglas

C
08/02/10
Douglas
N SHA 80 M --- M70 DS 124

Folio 1/1
SHA/80/M/---M70/MM/100 Rev. A Page 61 of 130

27/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

23/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

17/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/05/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Scale : N.A.

Format :

A4
Title :

Project :

IS

KKS

SHA

N/A

N/A

Doc Type :
-

BIMETALLIC
THERMOSTATIC
STEAM TRAPS
BD120 F22

Language : E

Consortium Participant or Subcontractor Document No. : 095140001


No of sheet : 4

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD002

1 of 4
Client Document No. :

80-L-M-36259

SHA/80/M/---M70/MM/100 Rev. A Page 62 of 130

BIMETALLIC THERMOSTATIC
STEAM TRAPS

BD120 F22

BIMETALLIC THERMOSTATIC
The operating principle is based on a balance between the steam
force ( pressure related ) trying to open the discharge valve and the
bimetal force ( temperature related ) which acts to close it. At saturated
steam temperature the bimetal force keeps the valve closed, while with
subcooled condensate the pressure opens the valve.

MAIN FEATURES

Free air discharge. Suitable on superheated steam. It withstands frost


and waterhammer. Modulating discharge only with condensate.

APPLICATIONS

DISCHARGE CAPACITY

Tracing lines
Marine applications
Turbines
Steam mains
Tanks

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

CONNECTIONS
SOCKET WELD

DOUGLAS ITALIA S.p.a.

ANSI B16.11

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max Differential pressure

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 63 of 130

Rev.: 4
Date: 27/07/09

ANSI 2500
430 bar
570C
110 bar
550C
110 bar

Dwg. N.

095140001

Pag. : 1/2

BIMETALLIC THERMOSTATIC STEAM TRAPS

BD120 F22
POS.

DESCRIPTION

MATERIALS

Body

ASTM A182 F22

Cover

ASTM A182 F22

Cover gasket RJ

ASTM A182 F304

Screen

AISI 304

Seat

NITRONIC 50 + STELLITE

Valve

NITRONIC 60

Bimetallic element

STAINESS STEEL

Gasket seat

ASTM A182 F316

Studs

ASTM A193 B16

Nuts

ASTM A194 Gr.7

Size
(inches)

S
SW
NPT
BSP

185

70

SPARES

Weight
(Kg)

200

200

35

INSTALLATION
The steam trap is designed for installation on horizontal line with the cover at the top. The steam trap may be used on superheated steam.
Condensate is discharged below steam temperature (30). Subcooling temperature may be adjusted on field without removing the trap from
the line. For information for this operation, to be performed only be qualified personnel, please ask our technical department.

HOW TO SERVICE
By installing a new valve assembly you can bring the BD 120 F22 steam trap to the as new from factory condition. Unscrew the 8 nuts (8).
Remove cover (2) and RJ gasket (3). Unscrew and remove valve assembly (5) with screen (4). Clean the inside of the trap and clean or
replace the screen (4). Screw in the new valve assembly (5) with screen (4) and reinstall cover (2) tightening the nuts (8).

MODEL

SIZE

BD120
BD120
BD120

1
1
1

DOUGLAS REF
CLIENT
CLIENT P.O. No.

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:
SOCKET WELD

002
012
022

TAG. No.:

CLIENT REF.
ITEM No.:

14LBA21AA202-M70 DS 002
13LBA21AA202-M70 DS 002
12LBA21AA202-M70 DS 002

1
1
1

Q.Ty.:
1
1
1

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S.p.a.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 4
Date: 27/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 64 of 130

Dwg. N.

095140001

Pag. : 2/2

27/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

23/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Scale : N.A.

Format :

A4
Title :

Project :

IS

KKS

SHA

N/A

N/A

Doc Type :

BIMETALLIC THERMOSTATIC
BD120 F22
VACUUM SERVICE

Language : E

DD

Consortium Participant or Subcontractor Document No. : 095140003


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD003

1 of 3
Client Document No. :

80-L-M-36260

SHA/80/M/---M70/MM/100 Rev. A Page 65 of 130

SHA/80/M/---M70/MM/100 Rev. A Page 66 of 130

BIMETALLIC THERMOSTATIC
STEAM TRAPS

BD120 F22
FOR VACUUM SERVICE

BIMETALLIC THERMOSTATIC
The operating principle is based on a balance between the steam
force ( pressure related ) trying to open the discharge valve and the
bimetal force ( temperature related ) which acts to close it. At saturated
steam temperature the bimetal force keeps the valve closed, while with
subcooled condensate the pressure opens the valve.

MAIN FEATURES

Free air discharge. Suitable on superheated steam. It withstands frost


and waterhammer. Modulating discharge only with condensate.

APPLICATIONS

DISCHARGE CAPACITY

Tracing lines
Marine applications
Turbines
Steam mains
Tanks

07-12-2009
Cold water capacities are 2 to 4 times greater than the above .
Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

CONNECTIONS
SOCKET WELD

DOUGLAS ITALIA S.p.a.

ANSI B16.11

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max Differential pressure

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 67 of 130

Rev.: 2
Date: 27/07/09

ANSI 2500
430 bar
570C
110 bar
550C
110 bar

Dwg. N.

095140003

Pag. : 1/2

BIMETALLIC THERMOSTATIC STEAM TRAPS

BD120 F22
POS.

FOR VACUUM SERVICE

DESCRIPTION

MATERIALS

Body

ASTM A182 F22

Cover

ASTM A182 F22

Cover gasket RJ

ASTM A182 F304

Screen

AISI 304

Seat

NITRONIC 50 + STELLITE

Valve

NITRONIC 60

Bimetallic element

STAINESS STEEL

Gasket seat

ASTM A182 F316

Studs

ASTM A193 B16

Nuts

ASTM A194 Gr.7

Size
(inches)

S
SW
NPT
BSP

185

70

SPARES

Weight
(Kg)

200

200

35

INSTALLATION
The steam trap is designed for installation on horizontal line with the cover at the top. The steam trap may be used on superheated steam.
Condensate is discharged below steam temperature (30). Subcooling temperature may be adjusted on field without removing the trap from
the line. For information for this operation, to be performed only be qualified personnel, please ask our technical department.

HOW TO SERVICE
By installing a new valve assembly you can bring the BD 120 F22 steam trap to the as new from factory condition. Unscrew the 8 nuts (8).
Remove cover (2) and RJ gasket (3). Unscrew and remove valve assembly (5) with screen (4). Clean the inside of the trap and clean or
replace the screen (4). Screw in the new valve assembly (5) with screen (4) and reinstall cover (2) tightening the nuts (8).

FOR WITHOUT VACUUM SERVICE


MODEL

SIZE

BD120
BD120
BD120

1
1
1

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:
SOCKET WELD

003
013
023

TAG. No.:

CLIENT REF.
ITEM No.:

14LBB21AA202-M70 DS 003
13LBB21AA202-M70 DS 003
12LBB21AA202-M70 DS 003

1
1
1

Q.Ty.:
1
1
1

FOR VACUUM SERVICE


MODEL

SIZE

BD120
BD120
BD120

1
1
1

DOUGLAS REF
CLIENT
CLIENT P.O. No.

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:
SOCKET WELD

003
013
023

TAG. No.:

CLIENT REF.
ITEM No.:

14MAN10AA202-M70 DS 003
13MAN10AA202-M70 DS 003
12MAN10AA202-M70 DS 003

1
1
1

Q.Ty.:
1
1
1

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S.p.a.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 2
Date: 27/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 68 of 130

Dwg. N.

095140003

Pag. : 2/2

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

17/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/05/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Scale : N.A.

Format :

A4
Title :

BIMETALLIC THERMOSTATIC
BD60 A105
Project :

IS

KKS

SHA

N/A

N/A

Language : E

Doc Type :
-

Consortium Participant or Subcontractor Document No. : 095140004


No of sheet : 4

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD004

1 of 4
Client Document No. :

80-L-M-36261

SHA/80/M/---M70/MM/100 Rev. A Page 69 of 130

BIMETALLIC THERMOSTATIC
STEAM TRAPS

BD60 A105

BIMETALLIC THERMOSTATIC
The operating principle is based on a balance between the steam
force ( pressure related ) trying to open the discharge valve and the
bimetal force ( temperature related ) which acts to close it. At saturated
steam temperature the bimetal force keeps the valve closed, while with
subcooled condensate the pressure opens the valve.

MAIN FEATURES

Free air discharge. Suitable on superheated steam. It withstands frost


and waterhammer. Modulating discharge only with condensate.

APPLICATIONS

DISCHARGE CAPACITY

Tracing lines
Marine applications
Turbines
Steam mains
Tanks

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max Differential pressure

CONNECTIONS
SOCKET WELD

DOUGLAS ITALIA S.p.a.

ANSI B16.11

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 70 of 130

Rev.: 2
Date: 06/07/09

ANSI 600
100 bar
425C
60 bar
340C
60 bar

Dwg. N.

095140004

Pag. : 1/2

POS.

Size

DESCRIPTION

SPARES

Body

Cover

Gasket SPW

F-GRAPHITE W-316

Valve assembly

STAINLESS STEEL

ASTM A105

AISI 316

F-GRAPHITE W-316

ASTM A105

Screen

Gasket SPW

Strainer cap

Bolts

(inches)
1

MATERIALS

ASTM A105
ASTM A193 B7

Weight
(Kg)

145

130

35

145

INSTALLATION
The steam trap can be installed on horizontal or vertical lines. Do not fit the trap upside down since this position will not allow the cleaning of
the strainer. For the same reason the directory of flow on vertical lines must be downwards. For installation with superheated steam, please
contact our Technical Department

HOW TO SERVICE
By installing a new element assembly you can bring the BD steam trap to the as new from factory condition. Unscrew the 8 bolts (8) and
remove cover (2) and gasket (3). Unscrew and remove the element (4). Clean the inside of the trap and screw in the element-gasket
assembly. Fit a new gasket (3) and reinstall cover (2) tightening the bolts (8). To service the strainer, unscrew cap (7), withdraw screen (5)
and clean or replace it. Screwing the cap back in place, always fit a new gasket (6). The discharge temperature may be adjusted without
removing the trap from the line. For information about this operation, to be performed only be qualified personnel, please ask our Technical
Department.

MODEL

SIZE

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:

BD60

SOCKET WELD

004

BD60

SOCKET WELD

014

BD60

SOCKET WELD

024

DOUGLAS REF
CLIENT
CLIENT P.O. No.

TAG. No.:

CLIENT REF.
ITEM No.:

14LBC15AA212-M70 DS 004
14LBC30AA204-M70 DS 004
14LBC90AA202-M70 DS 004
13LBC15AA212-M70 DS 004
13LBC30AA204-M70 DS 004
13LBC90AA202-M70 DS 004
12LBC15AA212-M70 DS 004
12LBC30AA204-M70 DS 004
12LBC90AA202-M70 DS 004

Q.Ty.:

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S.p.a.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 2
Date: 06/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 71 of 130

Dwg. N.

095140004

Pag. : 2/2

27/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Scale : N.A.

Format :

A4
Title :

Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

BIMETALLIC
THERMOSTATIC
STEAM TRAP
BD120 F22

Language : E

Consortium Participant or Subcontractor Document No. : 095140005


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD005

1 of 3
Client Document No. :

80-L-M-36262

SHA/80/M/---M70/MM/100 Rev. A Page 72 of 130

BIMETALLIC THERMOSTATIC
STEAM TRAPS

BD120 F22

BIMETALLIC THERMOSTATIC
The operating principle is based on a balance between the steam
force ( pressure related ) trying to open the discharge valve and the
bimetal force ( temperature related ) which acts to close it. At saturated
steam temperature the bimetal force keeps the valve closed, while with
subcooled condensate the pressure opens the valve.

MAIN FEATURES

Free air discharge. Suitable on superheated steam. It withstands frost


and waterhammer. Modulating discharge only with condensate.

APPLICATIONS

DISCHARGE CAPACITY

Tracing lines
Marine applications
Turbines
Steam mains
Tanks

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

CONNECTIONS
SOCKET WELD

DOUGLAS ITALIA S.p.a.

ANSI B16.11

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max Differential pressure

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 73 of 130

Rev.: 1
Date: 27/07/09

ANSI 2500
430 bar
570C
110 bar
550C
110 bar

Dwg. N.

095140005

Pag. : 1/2

BIMETALLIC THERMOSTATIC STEAM TRAPS

BD120 F22
POS.

DESCRIPTION

MATERIALS

Body

ASTM A182 F22

Cover

ASTM A182 F22

Cover gasket RJ

ASTM A182 F304

Screen

AISI 304

Seat

NITRONIC 50 + STELLITE

Valve

NITRONIC 60

Bimetallic element

STAINESS STEEL

Gasket seat

ASTM A182 F316

Studs

ASTM A193 B16

Nuts

ASTM A194 Gr.7

Size
(inches)

S
SW
NPT
BSP

185

70

SPARES

Weight
(Kg)

200

200

35

INSTALLATION
The steam trap is designed for installation on horizontal line with the cover at the top. The steam trap may be used on superheated steam.
Condensate is discharged below steam temperature (30). Subcooling temperature may be adjusted on field without removing the trap from
the line. For information for this operation, to be performed only be qualified personnel, please ask our technical department.

HOW TO SERVICE
By installing a new valve assembly you can bring the BD 120 F22 steam trap to the as new from factory condition. Unscrew the 8 nuts (8).
Remove cover (2) and RJ gasket (3). Unscrew and remove valve assembly (5) with screen (4). Clean the inside of the trap and clean or
replace the screen (4). Screw in the new valve assembly (5) with screen (4) and reinstall cover (2) tightening the nuts (8).

MODEL

SIZE

BD120
BD120
BD120

1
1
1

DOUGLAS REF
CLIENT
CLIENT P.O. No.

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:
SOCKET WELD

005
015
025

TAG. No.:

CLIENT REF.
ITEM No.:

14LBG05AA202-M70 DS 005
13LBG05AA202-M70 DS 005
12LBG05AA202-M70 DS 005

4
4
4

Q.Ty.:
1
1
1

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S.p.a.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 1
Date: 27/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 74 of 130

Dwg. N.

095140005

Pag. : 2/2

06/07/2009

S. GHISONI

REV

DATE

PREPARED

VOLPI

FOR APPROVAL

M. GHISONI

CHECKED

APPROVED

MODIFICATION

FUS
STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Scale : N.A.

Format :

A4
Title :

Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

BIMETALLIC
THERMOSTATIC
STEAM TRAPS
BD60 A105

Language : E

Consortium Participant or Subcontractor Document No. : 095140006


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD006

1 of 3
Client Document No. :

80-L-M-36263

SHA/80/M/---M70/MM/100 Rev. A Page 75 of 130

BIMETALLIC THERMOSTATIC
STEAM TRAPS

BD60 A105

BIMETALLIC THERMOSTATIC
The operating principle is based on a balance between the steam
force ( pressure related ) trying to open the discharge valve and the
bimetal force ( temperature related ) which acts to close it. At saturated
steam temperature the bimetal force keeps the valve closed, while with
subcooled condensate the pressure opens the valve.

MAIN FEATURES

Free air discharge. Suitable on superheated steam. It withstands frost


and waterhammer. Modulating discharge only with condensate.

APPLICATIONS

DISCHARGE CAPACITY

Tracing lines
Marine applications
Turbines
Steam mains
Tanks

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max Differential pressure

CONNECTIONS
SOCKET WELD

DOUGLAS ITALIA S.p.a.

ANSI B16.11

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 76 of 130

Rev.: 0
Date: 06/07/09

ANSI 600
100 bar
425C
60 bar
340C
60 bar

Dwg. N.

095140006

Pag. : 1/2

POS.

Size

DESCRIPTION

SPARES

Body

Cover

Gasket SPW

F-GRAPHITE W-316

Valve assembly

STAINLESS STEEL

ASTM A105

AISI 316

F-GRAPHITE W-316

ASTM A105

Screen

Gasket SPW

Strainer cap

Bolts

(inches)
1

MATERIALS

ASTM A105
ASTM A193 B7

Weight
(Kg)

145

130

35

145

INSTALLATION
The steam trap can be installed on horizontal or vertical lines. Do not fit the trap upside down since this position will not allow the cleaning of
the strainer. For the same reason the directory of flow on vertical lines must be downwards. For installation with superheated steam, please
contact our Technical Department

HOW TO SERVICE
By installing a new element assembly you can bring the BD steam trap to the as new from factory condition. Unscrew the 8 bolts (8) and
remove cover (2) and gasket (3). Unscrew and remove the element (4). Clean the inside of the trap and screw in the element-gasket
assembly. Fit a new gasket (3) and reinstall cover (2) tightening the bolts (8). To service the strainer, unscrew cap (7), withdraw screen (5)
and clean or replace it. Screwing the cap back in place, always fit a new gasket (6). The discharge temperature may be adjusted without
removing the trap from the line. For information about this operation, to be performed only be qualified personnel, please ask our Technical
Department.

MODEL

SIZE

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:

BD60

SOCKET WELD

006

BD60

SOCKET WELD

016

BD60

SOCKET WELD

026

DOUGLAS REF
CLIENT
CLIENT P.O. No.

TAG. No.:

CLIENT REF.
ITEM No.:

14LBG15AA202-M70 DS 006
14LBG30AA202-M70 DS 006
14LBG60AA202-M70 DS 006
13LBG15AA202-M70 DS 006
13LBG30AA202-M70 DS 006
13LBG60AA202-M70 DS 006
12LBG15AA202-M70 DS 006
12LBG30AA202-M70 DS 006
12LBG60AA202-M70 DS 006

Q.Ty.:

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S.p.a.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 0
Date: 06/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 77 of 130

Dwg. N.

095140006

Pag. : 2/2

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

17/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/05/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Scale : N.A.

Format :

A4
Title :

BALL FLOAT COMPRESSED


AIR TRAPS
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Language : E

Consortium Participant or Subcontractor Document No. : 095140007


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD007

1 of 3
Client Document No. :

80-L-M-36264

SHA/80/M/---M70/MM/100 Rev. A Page 78 of 130

BALL FLOAT
COMPRESSED AIR TRAPS

GX WCB

DESCRIPTION
A range of float operated traps for draining water from compressed air
lines.
Applications on aftercoolers , separators , compressed air mains.

MAIN FEATURES
Direct-acting float valve permits continuous drainage of water under
changing conditions of inlet pressure and load. Because valve is under
water during operation , air leakage is eliminated. Properly located it
will assure a supply of dry compressed air.

07-12-2009

OPERATION

DISCHARGE CAPACITY

Water entering the trap lifts the float and opens the discharge
valve. This adjusts the valve opening so that there is a
continuous flow of water through the trap. There are no
pressure fluctuations as the trap opens and closes.

NOTE
An equalizing line should be installed. This will equalize the
pressure to the trap , eliminate gas binding and permit a
smooth uninterrupted flow of condensate to the trap, the
equalizing line connection to the tank must be above the
level of any possible accumulation of condensate.

Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max. Differential pressure ( GX 14 )

CONNECTIONS
FLANGED

ANSI 150#/300#/600#/UNI/DIN

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 79 of 130

Rev.: 2
Date: 06/07/09

ANSI 150
20 bar
350C
14 bar
300C
14 bar

Dwg. N.

095140007

Pag. : 1/2

COMPRESSED AIR BALL FLOAT TRAPS

GX WCB
POS.
1
2
3
4
5
6
7
8
9

Size

DESCRIPTION
Body
Cover
Gasket
Seat
Valve
Lever
Ball float
Plug
Bolts

MATERIALS

SPARES

ASTM A216 WCB


ASTM A216 WCB
316 / GRAPHITE
AISI 316
AISI 316
AISI 316
AISI 316
INOX
ASTM A193 B7

X
X
X
X
X

Socket weld / Screwed / Flanged


S
A
B
C
Weight

150#

(Kg)

(inches)
165

213

71

180

11

SF

Kg

210

14.5

INSTALLATION
The steam trap must be fitted with the float arm in a horizontal plane so
that it rises and falls vertically with the flow direction indicated on the
body.

HOW TO SERVICE
By installing a new mechanism assembly (4),(5),(6),if necessary also a
ball float (7), you can bring the steam trap to the as new from factory
condition. This operation is carried out without removing the trap from the
pipeline. Always fit a new gasket (3) when reassembling.

MODEL

SIZE

GX14

GX14

GX14

DOUGLAS REF
CLIENT
CLIENT P.O. No.

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:
007
FLANGED 150 RF (125 250 AARH)

017
027

CLIENT REF.
TAG. No.:
ITEM No.:
14SCB20AA202-M70 DS 007
14SCB20AA204-M70 DS 007
13SCB20AA202-M70 DS 007
13SCB20AA204-M70 DS 007
12SCB20AA202-M70 DS 007
12SCB20AA204-M70 DS 007

Q.Ty.:

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 2
Date: 06/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 80 of 130

Dwg. N.

095140007

Pag. : 2/2

21/10/2009

S. GHISONI

REV

DATE

PREPARED

VOLPI

FOR APPROVAL

M. GHISONI

CHECKED

APPROVED

MODIFICATION

FUS
STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

Language : E

Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

BIMETALLIC THERMOSTATIC
STEAM TRAPS
BF20

Consortium Participant or Subcontractor Document No. : 09532002


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

1 of 3
Client Document No. :

80-L-M-36265

SHA/80/M---M70/DD008

SHA/80/M/---M70/MM/100 Rev. A Page 81 of 130

BIMETALLIC THERMOSTATIC
STEAM TRAPS

BF20

BIMETALLIC THERMOSTATIC
The operating principle is based on a balance between the steam
force ( pressure related ) trying to open the discharge valve and the
bimetal force ( temperature related ) which acts to close it. At saturated
steam temperature the bimetal force keeps the valve closed, while with
subcooled condensate the pressure opens the valve.

MAIN FEATURES

Free air discharge. Suitable on superheated steam. It withstands frost


and waterhammer. Modulating discharge only with condensate.

APPLICATIONS

DISCHARGE CAPACITY

Tracing lines
Marine applications
Turbines
Steam mains
Tanks

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

3/4

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max differential pressure
TMO: max working temperature

CONNECTIONS
SOCKET WELD

DOUGLAS ITALIA S. p. A.

ANSI B16.11

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 0
Date: 21/10/09

SHA/80/M/---M70/MM/100 Rev. A Page 82 of 130

ANSI 300
50 bar
390C
20 bar
350C

Dwg. N.

095325002

Pag. : 1/2

BIMETALLIC THERMOSTATIC STEAM TRAPS

BF20
POS.

DESCRIPTION

1
2
3
4
5
6
7
8

MATERIALS

Body
Cover
Valve assembly
Gasket SPW
Gasket SPW
Screen
Strainer cap
Bolts

Size

ASTM A105
ASTM A105
STAINLESS STEEL
F-GRAPHITE W-316
F-GRAPHITE W-316
AISI 304
ASTM A105
ASTM A193 B7

X
X
X
X

Weight

(inches)
3/4

SPARES

(Kg)
93

145

60

70

2.5

INSTALLATION
The steam trap can be installed on horizontal or vertical lines. Do not fit the trap upside down since this position will not allow the cleaning of
the strainer. For the same reason the directory of flow on vertical lines must be downwards. For installation with superheated steam, please
conctact our Technical Departement.

HOW TO SERVICE
By installing a new element assemly you can bring the BF steam trap to the as new from factory condition. This operation is carried out in
few minutes without removing the trap from the pipeline. Unscrew the 4 bolts (8) and remove cover (2). Unscrew and remove the element (3).
Clean the insede of the trap and screw in the new element assembly. Fit a new gasket (4) and reinstall cover (2) tightening the bolts (8). To
service the strainer, unscrew cap (7), withdraw screen (6) and clean or replace it. Screwing the cap back in place, always fit a new gasket (5).
The discharge temperature may be adjusted without removing the trap from the line. For informatin about this operation, to be performed only
by qualified personnel, please ask our Techincal Departement.

MODEL

SIZE

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:
002

004

BF20

3/4

SOCKET WELD

006

012

DOUGLAS REF
CLIENT
CLIENT P.O. No.

CLIENT REF.
TAG. No.:
14-QLB33 AT511 M70DS008
14-QLB33 AT511 M70DS008
14-QLC33 AT511 M70DS008
14-QLC33AT512 M70DS008
14-QLC33AT513 M70DS008
14-QLC33 AT514 M70DS008
13-QLB33 AT511 M70DS008
13-QLB33 AT511 M70DS008
13-QLC33 AT511 M70DS008
13-QLC33 AT512 M70DS008
13-QLC33 AT513 M70DS008
12-QLB33 AT511 M70DS008
12-QLB33 AT511 M70DS008
12QLC33 AT511 M70DS008
12QLC33 AT512 M70DS008
12QLC33 AT513 M70DS008
12-QLC33 AT514 M70DS008
80-QLB33 AT511 M70DS008
80-QLB33 AT521 M70DS008
80-QLB32 AT511 M70DS008
80-QLB32 AT521 M70DS008
80-QLC33 AT511 M70DS008
80-QLC33 AT521 M70DS008
80-QLC33 AT531 M70DS008
80-QLC33 AT532 M70DS008
80-QLC33 AT533 M70DS008

ITEM No.: Q. Ty.:

14-QLC33 AT515 M70DS008


14-QLC33 AT512 M70DS008
14-QLC33 AT522 M70DS008
14-QLC33 AT523 M70DS008
14-QLC33 AT524 M70DS008
14-QLC33 AT525 M70DS008

12

13-QLC33 AT514 M70DS008


13-QLC33 AT515 M70DS008
13-QLC33 AT521 M70DS008
13-QLC33 AT522 M70DS008
13-QLC33 AT523 M70DS008
13-QLC33 AT524 M70DS008
13-QLC33 AT525 M70DS008

12

12-QLC33 AT515 M70DS008


12-QLC33 AT521 M70DS008
12-QLC33 AT522 M70DS008
12-QLC33 AT523 M70DS008
12-QLC33 AT524 M70DS008
12-QLC33 AT525 M70DS008

18
12

80-QLC33 AT534 M70DS008


80-QLC32 AT541 M70DS008
80-QLC32 AT542 M70DS008
80-QLC32 AT543 M70DS008
80-QLC32 AT544 M70DS008
80-QLC32 AT551 M70DS008
80-QLC32 AT552 M70DS008
80-QLC32 AT553 M70DS008
80-QLC32 AT554 M70DS008

18

JOB NO 095325
ALSTOM POWER SYSTEM S.A.
911772 REV. 2

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC)

ITALIA
Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 0
Date: 21/10/09

SHA/80/M/---M70/MM/100 Rev. A Page 83 of 130

Dwg. N.

095325002

Pag. : 2/2

27/10/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

21/10/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

13/10/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

BALL FLOAT

Language : E

GX WCB
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Consortium Participant or Subcontractor Document No. : 095140032


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

1 of 3
Client Document No. :

80-L-M-36266

SHA/80/M---M70/DD101

SHA/80/M/---M70/MM/100 Rev. A Page 84 of 130

BALL FLOAT
COMPRESSED AIR TRAPS

GX WCB

DESCRIPTION
A range of float operated traps for draining water from compressed air
lines.
Applications on aftercoolers , separators , compressed air mains.

MAIN FEATURES
Direct-acting float valve permits continuous drainage of water under
changing conditions of inlet pressure and load. Because valve is under
water during operation , air leakage is eliminated. Properly located it
will assure a supply of dry compressed air.

OPERATION

DISCHARGE CAPACITY

Water entering the trap lifts the float and opens the discharge
valve. This adjusts the valve opening so that there is a
continuous flow of water through the trap. There are no
pressure fluctuations as the trap opens and closes.

NOTE
An equalizing line should be installed. This will equalize the
pressure to the trap , eliminate gas binding and permit a
smooth uninterrupted flow of condensate to the trap, the
equalizing line connection to the tank must be above the
level of any possible accumulation of condensate.

Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

3/4

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max. Differential pressure ( GX 14 )

CONNECTIONS
SCREWED

ANSI B1.20.1 (NPT) / BS21 (BSP)

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 85 of 130

Rev.: 4
Date: 27/10/09

ANSI 150
20 bar
350C
14 bar
300C
14 bar

Dwg. N.

095140032

Pag. : 1/2

COMPRESSED AIR BALL FLOAT TRAPS

GX WCB
FOR DOUGLAS ITEM 032
POS.
1
2
3
4
5
6
7
8
9

DESCRIPTION
Body
Cover
Gasket
Seat
Valve
Lever
Ball float
Plug
Bolts

MATERIALS

SPARES

ASTM A216 WCB


ASTM A352 LCC
316 / GRAPHITE
AISI 316
AISI 316
AISI 316
AISI 316
ASTM A182 F316L
ASTM A193 B7

X
X
X
X
X

FOR DOUGLAS ITEM 008 (095325)


POS.
1
2
3
4
5
6
7
8
9

DESCRIPTION
Body
Cover
Gasket
Seat
Valve
Lever
Ball float
Plug
Bolts

MATERIALS

SPARES

ASTM A352 LCC


ASTM A352 LCC
316 / GRAPHITE
AISI 316
AISI 316
AISI 316
AISI 316
ASTM A182 F316L
ASTM A193 B7

X
X
X
X
X

INSTALLATION
The steam trap must be fitted with the float arm in a horizontal plane so
that it rises and falls vertically with the flow direction indicated on the
body.

Size
(inches)

Screwed
A
B

Weight
(Kg)

3/4

165

213

180

11

71

HOW TO SERVICE
By installing a new mechanism assembly (4),(5),(6),if necessary also a
ball float (7), you can bring the steam trap to the as new from factory
condition. This operation is carried out without removing the trap from the
pipeline. Always fit a new gasket (3) when reassembling.

MODEL

SIZE

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:

GX14

3/4

SCREWED (NPT)

032

GX14

3/4

SCREWED (NPT)

008 (095325)

DOUGLAS REF
CLIENT
CLIENT P.O. No.

CLIENT REF.
TAG. No.:
ITEM No.:
80-QFA04 AT205 M70DS101
80-QFA06 AT206 M70DS101
80-QFA06 AT215 M70DS101
80-QFA08 AT205 M70DS101
80-QFA16 AT205 M70DS101
80-QFA18 AT205 M70DS101
80-QFB01 AT205 M70DS101
80-QFB02 AT205 M70DS101
80-QFB02 AT203 M70DS101
80-QFB02 AT208-M70DS101
80-QFB02 AT218 M70DS101
80-QFB02 AT222 M70DS101
80-QFB02 AT226 M70DS101
80-QFB02 AT230 M70DS101
80-QFB02 AT234 M70DS101
80-QFB02 AT242 M70DS101
80-QFB02 AT212 M70DS101
80-QFB02 AT271 M70DS101
80-QFB02 AT247 M70DS101
80-QFB02 AT251 M70DS101
80-QFB02 AT253 M70DS101
80-QFB02 AT237 M70DS101
80-QFB02 AT259 M70DS101
80-QFB02 AT261 M70DS101
80-QFB02 AT265 M70DS101
80-QFB02 AT267 M70DS101
80-QFB02 AT269 M70DS101
80-QFB02 AT240 M70DS101
80-QFB02 AT273 M70DS101
80-QFB02 AT275 M70DS101
80-QFB02 AT277 M70DS101
80-QFB02 AT279 M70DS101
80-QFB02 AT281 M70DS101
80-QFB02 AT283 M70DS101
80-QFB02 AT285 M70DS101
80-QFB02 AT287 M70DS101
80-QFB02 AT289 M70DS101
80-QFB02 AT291 M70DS101
80-QFB02 AT293 M70DS101

Q.Ty.:

27

12

JOB NO 095140 - 095325


ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 4
Date: 27/10/09

SHA/80/M/---M70/MM/100 Rev. A Page 86 of 130

Dwg. N.

095140032

Pag. : 2/2

27/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

BALL FLOAT

Language : E

GX WCB
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Consortium Participant or Subcontractor Document No. : 095140033


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD102

1 of 3
Client Document No. :

80-L-M-36268

SHA/80/M/---M70/MM/100 Rev. A Page 87 of 130

BALL FLOAT
COMPRESSED AIR TRAPS

GX WCB

DESCRIPTION
A range of float operated traps for draining water from compressed air
lines.
Applications on aftercoolers , separators , compressed air mains.

MAIN FEATURES
Direct-acting float valve permits continuous drainage of water under
changing conditions of inlet pressure and load. Because valve is under
water during operation , air leakage is eliminated. Properly located it
will assure a supply of dry compressed air.

OPERATION

DISCHARGE CAPACITY

Water entering the trap lifts the float and opens the discharge
valve. This adjusts the valve opening so that there is a
continuous flow of water through the trap. There are no
pressure fluctuations as the trap opens and closes.

NOTE
An equalizing line should be installed. This will equalize the
pressure to the trap , eliminate gas binding and permit a
smooth uninterrupted flow of condensate to the trap, the
equalizing line connection to the tank must be above the
level of any possible accumulation of condensate.

Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max. Differential pressure ( GX 14 )

CONNECTIONS
SCREWED

ANSI B1.20.1 (NPT) / BS21 (BSP)

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 88 of 130

Rev.: 1
Date: 27/07/09

ANSI 150
20 bar
350C
14 bar
300C
14 bar

Dwg. N.

095140033

Pag. : 1/2

COMPRESSED AIR BALL FLOAT TRAPS

GX WCB
POS.
1
2
3
4
5
6
7
8
9

Size

DESCRIPTION
Body
Cover
Gasket
Seat
Valve
Lever
Ball float
Plug
Bolts

MATERIALS

SPARES

ASTM A216 WCB


ASTM A216 WCB
316 / GRAPHITE
AISI 316
AISI 316
AISI 316
AISI 316
INOX
ASTM A193 B7

X
X
X
X
X

Socket weld / Screwed / Flanged


S
A
B
C
Weight

150#

(Kg)

(inches)
165

213

71

180

11

SF

Kg

210

14.5

INSTALLATION
The steam trap must be fitted with the float arm in a horizontal plane so
that it rises and falls vertically with the flow direction indicated on the
body.

HOW TO SERVICE
By installing a new mechanism assembly (4),(5),(6),if necessary also a
ball float (7), you can bring the steam trap to the as new from factory
condition. This operation is carried out without removing the trap from the
pipeline. Always fit a new gasket (3) when reassembling.

MODEL
GX14

SIZE
1

DOUGLAS REF
CLIENT
CLIENT P.O. No.

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:
SCREWED (NPT)

033

CLIENT REF.
TAG. No.:
ITEM No.:
80QFA10 AT205-M70DS 102
80QFA20 AT205-M70DS 102
80QFA30 AT205-M70DS 102
80QFA40 AT205-M70DS 102
80QFA50 AT205 M70 DS 102

Q.Ty.:
5

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 1
Date: 27/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 89 of 130

Dwg. N.

095140033

Pag. : 2/2

21/10/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

13/10/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

17/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/05/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

INVERTED BUCKET STEAM


TRAPS IA A105
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Language : E

Consortium Participant or Subcontractor Document No. : 095140034


No of sheet :3

Power Systems

Sheet :

Plant
Alstom document No :

1 of 3
Client Document No. :

80L-M-36267

SHA/80/M---M70/DD103

SHA/80/M/---M70/MM/100 Rev. A Page 90 of 130

INVERTED BUCKET
STEAM TRAPS

IA A105
INVERTED BUCKET
This trap uses an inverted bucket that floats when steam is present
and sinks when condensate exceeds a predetermined liquid level.
When the bucket floats the valve at the top of the trap is closed .
When it sinks the valve will open. On start up the bucket is down end
the valve is wide open , when condensate and air enters the trap it
flows directly into the bucket. The condensate falls into the trap body
whereas air collects at the top of the bucket and causes it to float
thereby closing the valve. Air is released through a vent at the top of
the bucket and collects in the top of the trap until the bucket sinks
opening the valve and allows the discharge of air and condensate.
When steam is formed , it collects in the top of the bucket causing it to
float thereby closing the valve. The bucket will sink again when
condensate reaches the predetermined level and the cycle starts over.

MAIN FEATURES

Discharge of condensate at steam temperature. Simple and reliable


construction. Slow discharge of air. Suitable for superheated steam. It
whith stands waterhammer.

APPLICATIONS

DISCHARGE CAPACITY

Heater batteries
Heat exchangers
Pans
Turbines
Drying cilinders
Ironing machines

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max. Differential pressure
(IA 10 )

CONNECTIONS
Socket weld

ANSI B 16.11

DOUGLAS ITALIA S.p.a.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 91 of 130

Rev.: 5
Date: 21/10/09

ANSI 300
50 bar
400C
26 bar
380C
10 bar

Dwg. N.

095140034

Pag. : 1/2

INVERTED BUCKET STEAM TRAPS

IA A105
MATERIALS

PART

POS

IA10 & IA17 & IA26


1

Cover

A105

Body

AISI 316L

Seat

AISI 316L

Valve

AISI 316/316L

Lever

AISI 316L

Bucket

Tube

Reduction

Size

AISI 316L
AISI 316/316L

A105

(inches)
1

MODEL

MODEL & CONNECTIONS


SIZE CONNECTIONS DI ITEM No.:

IA 10

SOCKET WELD

034

IA 10

SOCKET WELD

042

IA10

SOCKET WELD

009 (095325)

DOUGLAS REF
CLIENT
CLIENT P.O. No.

DOUGLAS ITALIA S.p.a.

Weight
(Kg)

164

145

127

80

1.8

CLIENT REF.
TAG. No.:

ITEM No.:

Q.ty.:

39

18

80-QLB32 AT203 M70DS103


80-QLB34 AT242 M70DS103
80-QLB32 AT247 M70DS103
80-QLB34 AT209 M70DS103
80-QLB32 AT210 M70DS103
80-QLB34 AT211 M70DS103
80-QLB32 AT214 M70DS103
80-QLB34 AT213-M70DS103
80-QLB32 AT218 M70DS103
80-QLB34 AT215 M70DS103
80-QLB32 AT222 M70DS103
80-QLB34 AT317 M70DS103
80-QLB32 AT224 M70DS103
80-QLB34 AT322 M70DS103
80-QLB32 AT227 M70DS103
80-QLB34 AT327 M70DS103
80-QLB32 AT235 M70DS103
80-QLB34 AT332 M70DS103
80-QLB32 AT239 M70DS103
12-QLB33 AT202 M70DS103
80-QLB32 AT243 M70DS103
13-QLB33 AT202 M70DS103
80-QLB33 AT202 M70DS103
14-QLB33 AT202 M70DS103
80-QLB33 AT206 M70DS103
12-QLB33 AT204 M70DS103
80-QLB33 AT210 M70DS103
13-QLB33 AT204 M70DS103
80-QLB33 AT234 M70DS103
14-QLB33 AT204 M70DS103
80-QLB34 AT202 M70DS103
12-QLB33 AT241 M70DS103
80-QLB34 AT205 M70DS103
13-QLB33 AT241 M70DS103
80-QLB34 AT208 M70DS103
14-QLB33 AT241 M70DS103
80-QLB24 AT232 M70DS103
80-QLB32 AT249 M70DS103
80QLB34AT312-M70 DS 103
80-QLB34 AT217 M70DS103
80-QLB34 AT240 M70DS103
80-QLB34 AT219 M70DS103
80-QLB35 AT202 M70DS103
80-QLB34 AT221 M70DS103
80-QLB35 AT204 M70DS103
80-QLB34 AT223 M70DS103
80-QLB35 AT206 M70DS103
80-QLB34 AT225 M70DS103
80-QLB35 AT208 M70DS103
80-QLB34 AT227 M70DS103
80-QLB35 AT210 M70DS103
80-QLB34 AT229 M70DS103
80-QLB35 AT212 M70DS103
80-QLB34 AT235 M70DS103
80-QLB35 AT214 M70DS103
80-QLB34 AT239 M70DS103
80-QLB35 AT216 M70DS103

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1
Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 5
Date: 21/10/09

SHA/80/M/---M70/MM/100 Rev. A Page 92 of 130

Dwg. N.

095140034

Pag. : 2/2

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

17/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/05/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Scale : N.A.

Format :

A4
Title :

INVERTED BUCKET STEAM


TRAPS IDHO A105
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Language : E

Consortium Participant or Subcontractor Document No. : 095140035


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD105

1 of 3
Client Document No. :

80-L-M-36269

SHA/80/M/---M70/MM/100 Rev. A Page 93 of 130

INVERTED BUCKET
STEAM TRAPS

IDHO A105
INVERTED BUCKET
This trap uses an inverted bucket that floats when steam is present
and sinks when condensate exceeds a predetermined liquid level.
When the bucket floats the valve at the top of the trap is closed
. When it sinks the valve will open. On start up the bucket is down
end the valve is wide open , when condensate and air enters the
trap it flows directly into the bucket. The condensate falls into the
trap body whereas air collects at the top of the bucket and causes
it to float thereby closing the valve. Air is released through a vent
at the top of the bucket and collects in the top of the trap until the
bucket sinks opening the valve and allows the discharge of air and
condensate. When steam is formed , it collects in the top of the
bucket causing it to float thereby closing the valve. The bucket will
sink again when condensate reaches the pre determined level and
the cycle starts over.

MAIN FEATURES

Discharge of condensate at steam temperature. Simple and reliable


construction. Slow discharge of air. Suitable for superheated steam. It
whith stands water hammer.

APPLICATIONS

DISCHARGE CAPACITY

Heater batteries
Heat exchangers
Pans
Turbines
Drying cilinders
Ironing machines

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max. Differential pressure
( IDHO 18 )

CONNECTIONS
Socket weld

ANSI B 16.11

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 94 of 130

Rev.: 2
Date: 06/07/09

ANSI 600
100 bar
400C
75 bar
350C
18 bar

Dwg. N.

095140035

Pag. : 1/2

INVERTED BUCKET STEAM TRAPS

IDHO A105
POS DESCRIPTION

MATERIALS

Flange

S
SW

(inches)

Size
1

320

470

SPARES

ASTM A105

Body Pipe

ASTM A106 Gr.B

Cap

ASTM A234 WPB

Cover

Cover gasket SPW

F-GRAPHITE W-316

Studs

ASTM A193 B7

Nuts

ASTM A194 2H

Seat

AISI 410

Valve

AISI 416

Lever

AISI 304

Bucket

AISI 304

Flange

ASTM A105

ASTM A105
X

Weight
(Kg)

394

100

INSTALLATION
The trap must be installed vertically. The inlet must be at the bottom with the trap installed below the drain point in order to maintain the water
seal around the bucket. A protective strainer is always recommended upstream of the trap. Always ensure that the trap is properly sized. With
very low condensate loads and/or with superheated steam, the installation of a check valve upstream the trap is recommended

HOW TO SERVICE
Before doing any maintenance work always ensure that the trap is isolated and pressure is dissipated. Undo cover nuts (5), remove cover (2)
with all mechanism and cover gasket (3). Unlock the bucket (7) from valve lever (6). Remove the valve guide undoing to the screw. Remove
valve seat from cover (2). Screw in a new valve seat. Reinstall valve guide with lever and bucket (7). Refit cover (2), using new gasket (3).

MODEL

IDHO18

SIZE

MODEL & CONNECTIONS


CONNECTIONS DOUGLAS ITEM No.:

DOUGLAS REF
CLIENT
CLIENT P.O. No.

SOCKET WELD

035

CLIENT REF.
ITEM No.:

TAG. No.:

80QLB11AT202-M70 DS 105
80QLB11AT212-M70 DS 105
80QLB11AT222-M70 DS 105
80QLB12AT202-M70 DS 105
80QLB12 AT205-M70DS105
80QLB12AT207-M70 DS 105
80QLB12AT209-M70DS105
80QLB13AT202-M70 DS 105
80QLB12AT110-M70 DS 105
80QLB12AT212-M70DS105
80QLB12AT216-M70 DS 105
80QLB12AT220-M70 DS 105
80QLB12AT224-M70 DS 105
80QLB12AT228-M70 DS 105
80QLB12AT232-M70DS105
80QLB12AT236-M70 DS 105

Q.ty.:

10

16

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370 AMD 1

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 2
Date: 06/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 95 of 130

Dwg. N.

095140035

Pag. : 2/2

06/07/2009

S. GHISONI

VOLPI

REV

DATE

PREPARED

CHECKED

FOR APPROVAL

M .GHISONI
APPROVED

MODIFICATION

FUS
STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

INVERTED BUCKET
STEAM TRAPS
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Language : E

IA A105

Consortium Participant or Subcontractor Document No. : 095140036


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD106

1 of 3
Client Document No. :

80-L-M-36270

SHA/80/M/---M70/MM/100 Rev. A Page 96 of 130

INVERTED BUCKET
STEAM TRAPS

IA A105
INVERTED BUCKET
This trap uses an inverted bucket that floats when steam is present
and sinks when condensate exceeds a predetermined liquid level.
When the bucket floats the valve at the top of the trap is closed .
When it sinks the valve will open. On start up the bucket is down end
the valve is wide open , when condensate and air enters the trap it
flows directly into the bucket. The condensate falls into the trap body
whereas air collects at the top of the bucket and causes it to float
thereby closing the valve. Air is released through a vent at the top of
the bucket and collects in the top of the trap until the bucket sinks
opening the valve and allows the discharge of air and condensate.
When steam is formed , it collects in the top of the bucket causing it to
float thereby closing the valve. The bucket will sink again when
condensate reaches the predetermined level and the cycle starts over.

MAIN FEATURES

Discharge of condensate at steam temperature. Simple and reliable


construction. Slow discharge of air. Suitable for superheated steam. It
whith stands waterhammer.

APPLICATIONS

DISCHARGE CAPACITY

Heater batteries
Heat exchangers
Pans
Turbines
Drying cilinders
Ironing machines

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max. Differential pressure
(IA 10 )

CONNECTIONS
Socket weld

ANSI B 16.11

DOUGLAS ITALIA S.p.a.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 97 of 130

Rev.: 0
Date: 06/07/09

ANSI 300
50 bar
400C
26 bar
380C
10 bar

Dwg. N.

095140036

Pag. : 1/2

INVERTED BUCKET STEAM TRAPS

IA A105
MATERIALS

PART

POS

IA10 & IA17 & IA26


1

Cover

A105

Body

AISI 316L

Seat

AISI 316L

Valve

AISI 316/316L

Lever

AISI 316L

Bucket

Tube

Reduction

Size

AISI 316L
AISI 316/316L

A105

(inches)
1

MODEL

MODEL & CONNECTIONS


SIZE CONNECTIONS DI ITEM No.:

IA 10

SOCKET WELD

036

IA 10

SOCKET WELD

043

DOUGLAS REF
CLIENT
CLIENT P.O. No.

DOUGLAS ITALIA S.p.a.

Weight
(Kg)

164

145

127

80

1.8

CLIENT REF.
TAG. No.:
80QLB21AT202-M70 DS 106
80QLB22AT209-M70 DS 106
80QLB22AT211-M70 DS 106
80QLB22 AT213-M70 DS 106
80QLB22AT216-M70 DS 106
89QLB20AT202-M70 DS 106
89QLB20AT211-M70 DS 106
89QLB20AT213-M70 DS 106
89QLB20AT215M70 DS 106
89QLB20AT221-M70 DS 106
89QLB20AT229-M70 DS 106
89QLB20AT235-M70 DS 106
89QLB20AT239-M70 DS 106

ITEM No.:

Q.ty.:

11

10

11

15

80QLB22AT203-M70 DS 106
80QLB22AT210-M70 DS 106
80QLB22AT212-M70 DS 106
80QLB23AT202-M70 DS 106
80QLB22AT220-M70 DS 106
89QLB20AT206-M70 DS 106
89QLB20AT212-M70 DS 106
89QLB20AT214-M70 DS 106
89QLB20AT216-M70 DS 106
89QLB20AT225-M70 DS 106
89QLB20AT233-M70 DS 106
89QLB20AT237-M70 DS 106

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1
Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 0
Date: 06/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 98 of 130

Dwg. N.

095140036

Pag. : 2/2

18/11/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

23/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

17/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/05/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

INVERTED BUCKET STEAM


TRAPS IDHO A105
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Language : E

Consortium Participant or Subcontractor Document No. : 095140008


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

1 of 3
Client Document No. :

80-L-M-36271

SHA/80/M---M70/DD108

SHA/80/M/---M70/MM/100 Rev. A Page 99 of 130

INVERTED BUCKET
STEAM TRAPS

IDHO A105
INVERTED BUCKET
This trap uses an inverted bucket that floats when steam is present
and sinks when condensate exceeds a predetermined liquid level.
When the bucket floats the valve at the top of the trap is closed
. When it sinks the valve will open. On start up the bucket is down
end the valve is wide open , when condensate and air enters the
trap it flows directly into the bucket. The condensate falls into the
trap body whereas air collects at the top of the bucket and causes
it to float thereby closing the valve. Air is released through a vent
at the top of the bucket and collects in the top of the trap until the
bucket sinks opening the valve and allows the discharge of air and
condensate. When steam is formed , it collects in the top of the
bucket causing it to float thereby closing the valve. The bucket will
sink again when condensate reaches the pre determined level and
the cycle starts over.

MAIN FEATURES

Discharge of condensate at steam temperature. Simple and reliable


construction. Slow discharge of air. Suitable for superheated steam. It
whith stands water hammer.

APPLICATIONS

DISCHARGE CAPACITY

Heater batteries
Heat exchangers
Pans
Turbines
Drying cilinders
Ironing machines

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max. Differential pressure
( IDHO 18 )

CONNECTIONS
BUTTWELD

According to ANSI B16.25

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 100 of 130

Rev.: 4
Date: 18/11/09

ANSI 600
100 bar
400C
75 bar
350C
18 bar

Dwg. N.

095140008

Pag. : 1/2

INVERTED BUCKET STEAM TRAPS

IDHO A105
POS.

DESCRIPTION

MATERIALS

SPARES

8
Flange

ASTM A105

Body

Cover

Cover gasket

Studs

ASTM A193 B7

Nuts

ASTM A194 2H

Seat

AISI 410

Valve

AISI 416

Lever

AISI 304

AISI 304

ASTM A105

Pipe

ASTM A106 Gr.B

Cap

ASTM A234 WPB


ASTM A105

Bucket

Reduction

Size
(inches)

316 / GRAPHITE

S
BW
NPT
SW

440

470

Weight
(Kg)

414

110

INSTALLATION
The trap must be installed vertically. The inlet must be at the bottom with the trap installed below the drain point in order to maintain the water
seal around the bucket. A protective strainer is always recommended upstream of the trap. Always ensure that the trap is properly sized. With
very low condensate loads and/or with superheated steam, the installation of a check valve upstream the trap is recommended

HOW TO SERVICE
Before doing any maintenance work always ensure that the trap is isolated and pressure is dissipated. Undo cover nuts (5), remove cover (2)
with all mechanism and cover gasket (3). Unlock the bucket (7) from valve lever (6). Remove the valve guide undoing to the screw. Remove
valve seat from cover (2). Screw in a new valve seat. Reinstall valve guide with lever and bucket (7). Refit cover (2), using new gasket (3).

MODEL

SIZE

IDHO18

IDHO18

IDHO18

DOUGLAS REF
CLIENT
CLIENT P.O. No.

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:
008

BUTTWELD SCH. STD


According to ANSI B16. 25

018

028

CLIENT REF.
TAG. No.:
ITEM No.:
14QLC01AT202-M70 DS 108
14QLC01AT204-M70 DS 108
12
14QLC02AT202-M70 DS 108
14QLC02AT204-M70 DS 108
13QLC01AT202-M70 DS 108
13QLC01AT204-M70 DS 108
12
13QLC02AT202-M70 DS 108
13QLC02AT204-M70 DS 108
12QLC01AT202-M70 DS 108
12QLC01AT204-M70 DS 108
12
12QLC02AT202-M70 DS 108
12QLC02AT204-M70 DS 108

Q.Ty.:
4

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 4
Date: 18/11/09

SHA/80/M/---M70/MM/100 Rev. A Page 101 of 130

Dwg. N.

095140008

Pag. : 2/2

06/07/2009

S. GHISONI

REV

DATE

PREPARED

VOLPI

FOR APPROVAL

M. GHISONI

CHECKED

APPROVED

MODIFICATION

FUS
STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

INVERTED BUCKET
STEAM TRAPS
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Language : E

IA A105

Consortium Participant or Subcontractor Document No. : 095140037


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD109

1 of 3
Client Document No. :

80-L-M-36272

SHA/80/M/---M70/MM/100 Rev. A Page 102 of 130

INVERTED BUCKET
STEAM TRAPS

IA A105
INVERTED BUCKET
This trap uses an inverted bucket that floats when steam is present
and sinks when condensate exceeds a predetermined liquid level.
When the bucket floats the valve at the top of the trap is closed .
When it sinks the valve will open. On start up the bucket is down end
the valve is wide open , when condensate and air enters the trap it
flows directly into the bucket. The condensate falls into the trap body
whereas air collects at the top of the bucket and causes it to float
thereby closing the valve. Air is released through a vent at the top of
the bucket and collects in the top of the trap until the bucket sinks
opening the valve and allows the discharge of air and condensate.
When steam is formed , it collects in the top of the bucket causing it to
float thereby closing the valve. The bucket will sink again when
condensate reaches the predetermined level and the cycle starts over.

MAIN FEATURES

Discharge of condensate at steam temperature. Simple and reliable


construction. Slow discharge of air. Suitable for superheated steam. It
whith stands waterhammer.

APPLICATIONS

DISCHARGE CAPACITY

Heater batteries
Heat exchangers
Pans
Turbines
Drying cilinders
Ironing machines

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max working pressure
TMO: max working temperature
Max. Differential pressure
(IA 10 )

CONNECTIONS
Socket weld

ANSI B 16.11

DOUGLAS ITALIA S.p.a.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 103 of 130

Rev.: 0
Date: 06/07/09

ANSI 300
50 bar
400C
26 bar
380C
10 bar

Dwg. N.

095140037

Pag. : 1/2

INVERTED BUCKET STEAM TRAPS

IA A105
MATERIALS

PART

POS

IA10 & IA17 & IA26


1

Cover

A105

Body

AISI 316L

Seat

AISI 316L

Valve

AISI 316/316L

Lever

AISI 316L

Bucket

Tube

AISI 316L

Reduction

AISI 316/316L

Size

A105

(inches)
1

MODEL
IA 10

MODEL & CONNECTIONS


SIZE CONNECTIONS DI ITEM No.:
1
SOCKET WELD
037

DOUGLAS REF
CLIENT
CLIENT P.O. No.

DOUGLAS ITALIA S.p.a.

Weight
(Kg)

164

145

127

80

1.8

CLIENT REF.
TAG. No.:
80QLC02AT002-M70 DS 109

80QLC03AT002-M70 DS 109

ITEM No.:
13

Q.ty.:
2

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1
Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 0
Date: 06/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 104 of 130

Dwg. N.

095140037

Pag. : 2/2

21/10/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

13/10/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

17/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/05/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

FORGED STEEL Y TYPE


STRAINER DOUGLAS
F800 A105
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Language : E

Consortium Participant or Subcontractor Document No. : 095140038


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

1 of 3
Client Document No. :

80-L-M-36274

SHA/80/M---M70/DD120

SHA/80/M/---M70/MM/100 Rev. A Page 105 of 130

FORGED STEEL Y
TYPE STRAINER DOUGLAS

F800 A105

STRAINERS
Designed to ANSI B16.34 the strainer bodies are
produced with a superior wall thickness for corrosion
allowance.
Standard strainers are equipped with screens for the
average service of most mediums ( steam, gas, air, oil,
chemicals , etc. ).
The large screen open area ensures an efficient filtering
action with a low pressure drop.
Filtering area to inlet area ratio is larger than 3 to 1 .
Screens area manufactured with perforated plate in the
materials and with the perforation specified in the
relevant tables .
Screens with different perforation ( or wire mesh ) and
materials may be manufactured on request.

INSTALLATION

CORRECT

INCORRECT

CORRECT

INCORRECT

All strainers should be mounted as close as possible to the valve or machinery which they are being installed to protect. It is
important to ensure that the strainer installed with the flow following the same direction as the flow direction arrow cast onto the
strainer body.
For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.
Y strainers should never be installed in vertical pipelines in the upward flow condition. ( see above )

SIZES
3/4 1.1/2

LIMITING CONDITIONS ( according to ISO 6552 )


CONNECTIONS
Screwed

DOUGLAS ITALIA S. p. A.

ANSI B1.20.1 (NPT)

According to the body rating ( ANSI B16.34 )


F800 ANSI 800

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 106 of 130

Rev.: 5
Date: 21/10/09

Dwg. N.

095140038

Pag. : 1/2

FORGED STEEL Y TYPE STRAINER DOUGLAS

F800 A105
POS.
1
2
3
4
5

DESCRIPTION

MATERIALS

Body
Screen
Plug
Gasket SPW
Drain plug

Size
(inches)

SPARES

ASTM A105
AISI 316
ASTM A105
F-GRAPHITE W-316
ASTM A105

DRAIN
PLUG

H1

Weight
(Kg)

3/4
1/4 NPT
110
75
100
46
1.1/2
1/4 NPT
180
144
200
85
Dimension : S, H , H1 , C , are in millimetres ( mm)

1.2
6

HOW TO SERVICE
Strainer maintenance should be made at least once year, or whenever the
pressure drop is found to be in excess of the normal figures. A quick cleanup system, to made approximately once a month, is to blow-off small
impurities trough the drain-plug (5). It is recommended to install a drain
valve by a nipple to the drain hole to speed-up this operation. For a
complete maintenance follow the points here below: -1- Be sure that the
main line has been shut-off. -2- Remove cover (3) and gasket (4). -3Withdraw screen (2) an carefully inspect it for damages. If any hole in the
screen is found obstructed, clean it with compressed air and / or any
suitable tool. If the screen is broken in any part or out of shape, replace it
with a new spare one. Never reinstall a broken or distorted screen. -4Carefully clean the inside of the strainer body. -5- Fit a new gasket (4). -6Install the new screen or the cleaned one (2). Be sure to centre the screen
in the upper seat. -7- Put in place cover (3). Be sure that drain plug (5) is
closed. -8- Slowly give pressure to the line, checking for leakages.
9- Write on the strainer body the date of this maintenance operation.

MODEL

F800

F800

SIZE

MODEL & CONNECTIONS


CONNECTIONS DOUGLAS ITEM No.:

3/4

3/4

DOUGLAS REF
CLIENT
CLIENT P.O. No.

SCREWED (NPT)

SCREWED (NPT)

038

010 (095325)

CLIENT REF.
ITEM No.: PERFORATIONS

TAG. No.:
80-QFA06 AT202 M70DS120
80-QFA06 AT211 M70DS120
80-QFA08 AT201 M70DS120
80-QFA16 AT201 M70DS120
80-QFA18 AT201 M70DS120
80-QFB01 AT201 M70DS120
80-QFB02 AT201M70DS120
80-QFB02 AT202 M70DS120
80-QFB02 AT207 M70DS120
80-QFB02 AT216 M70DS120
80-QFB02 AT217 M70DS120
80-QFB02 AT221 M70DS120
80-QFB02 AT224 M70DS120
80-QFB02 AT225 M70DS120
80-QFB02 AT211 M70DS120
80-QFB02 AT229 M70DS120
80-QFB02 AT233 M70DS120
80-QFB02 AT241 M70DS 120
80-QFB02 AT270 M70DS120
80-QFB02 AT236 M70DS120
80-QFB02 AT248 M70DS 120
80-QFB02 AT252 M70DS120
80-QFB02 AT260 M70DS120
80-QFB02 AT264 M70DS120
80-QFB02 AT266 M70DS120
80-QFB02 AT268 M70DS120
80-QFA04 AT201 M70DS120
80-QFB02 AT250 M70DS120
80-QFB02 AT272 M70DS120
80-QFB02 AT274 M70DS120
80-QFB02 AT276 M70DS120
80-QFB02 AT278 M70DS120
80-QFB02 AT280 M70DS120
80-QFB02 AT282 M70DS120
80-QFB02 AT284 M70DS120
80-QFB02 AT286 M70DS120
80-QFB02 AT288 M70DS120
80-QFB02 AT290 M70DS120
80-QFB02 AT292 M70DS120

14

Q. ty.:

27

Perf. Plate 3 +
MESH 40 Open 0.4
mm

14

12

JOB NO 095140 - 095325


ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 5
Date: 21/10/09

SHA/80/M/---M70/MM/100 Rev. A Page 107 of 130

Dwg. N.

095140038

Pag. : 2/2

06/07/2009

S. GHISONI

REV

DATE

PREPARED

VOLPI

FOR APPROVAL

M. GHISONI

CHECKED

APPROVED

MODIFICATION

FUS
STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

FORGED Y STRAINERS

Language : E

F800 A105
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Consortium Participant or Subcontractor Document No. : 095140039


No of sheet : 3

Power Systems

Sheet :

Plant
Alstom document No :

SHA/80/M---M70/DD121

1 of 3
Client Document No. :

80-L-M-36275

SHA/80/M/---M70/MM/100 Rev. A Page 108 of 130

FORGED STEEL Y
TYPE STRAINER DOUGLAS

F800 A105

STRAINERS
Designed to ANSI B16.34 the strainer bodies are
produced with a superior wall thickness for corrosion
allowance.
Standard strainers are equipped with screens for the
average service of most mediums ( steam, gas, air, oil,
chemicals , etc. ).
The large screen open area ensures an efficient filtering
action with a low pressure drop.
Filtering area to inlet area ratio is larger than 3 to 1 .
Screens area manufactured with perforated plate in the
materials and with the perforation specified in the
relevant tables .
Screens with different perforation ( or wire mesh ) and
materials may be manufactured on request.

INSTALLATION

CORRECT

INCORRECT

CORRECT

INCORRECT

All strainers should be mounted as close as possible to the valve or machinery which they are being installed to protect. It is
important to ensure that the strainer installed with the flow following the same direction as the flow direction arrow cast onto the
strainer body.
For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.
Y strainers should never be installed in vertical pipelines in the upward flow condition. ( see above )

SIZES
3/4 1.1/2

LIMITING CONDITIONS ( according to ISO 6552 )


CONNECTIONS
Screwed

DOUGLAS ITALIA S. p. A.

ANSI B1.20.1 (NPT)

According to the body rating ( ANSI B16.34 )


F800 ANSI 800

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 109 of 130

Rev.: 0
Date: 06/07/09

Dwg. N.

095140039

Pag. : 1/2

FORGED STEEL Y TYPE STRAINER DOUGLAS

F800 A105
POS.
1
2
3
4
5

DESCRIPTION

MATERIALS

Body
Screen
Plug
Gasket SPW
Drain plug

Size
(inches)

SPARES

ASTM A105
AISI 316
ASTM A105
F-GRAPHITE W-316
ASTM A105

DRAIN
PLUG

H1

Weight
(Kg)

3/4
1/4 NPT
110
75
100
46
1.1/2
1/4 NPT
180
144
200
85
Dimension : S, H , H1 , C , are in millimetres ( mm)

1.2
6

HOW TO SERVICE
Strainer maintenance should be made at least once year, or whenever the
pressure drop is found to be in excess of the normal figures. A quick cleanup system, to made approximately once a month, is to blow-off small
impurities trough the drain-plug (5). It is recommended to install a drain
valve by a nipple to the drain hole to speed-up this operation. For a
complete maintenance follow the points here below: -1- Be sure that the
main line has been shut-off. -2- Remove cover (3) and gasket (4). -3Withdraw screen (2) an carefully inspect it for damages. If any hole in the
screen is found obstructed, clean it with compressed air and / or any
suitable tool. If the screen is broken in any part or out of shape, replace it
with a new spare one. Never reinstall a broken or distorted screen. -4Carefully clean the inside of the strainer body. -5- Fit a new gasket (4). -6Install the new screen or the cleaned one (2). Be sure to centre the screen
in the upper seat. -7- Put in place cover (3). Be sure that drain plug (5) is
closed. -8- Slowly give pressure to the line, checking for leakages.
9- Write on the strainer body the date of this maintenance operation.

MODEL
F800

SIZE

MODEL & CONNECTIONS


CONNECTIONS DOUGLAS ITEM No.:

1.1/2

DOUGLAS REF
CLIENT
CLIENT P.O. No.

SCREWED (NPT)

039

CLIENT REF.
ITEM No.: PERFORATIONS

TAG. No.:
80QFA10AT201-M70 DS 121
80QFA20AT201-M70 DS 121
80QFA30AT201-M70 DS 121
80QFA40AT201-M70 DS 121
80QFA50AT201-M70 DS 121

15

Perf. Plate 0.8 +


MESH 40 Open 0.4
mm

Q. ty.:
5

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 0
Date: 06/07/09

SHA/80/M/---M70/MM/100 Rev. A Page 110 of 130

Dwg. N.

095140039

Pag. : 2/2

21/10/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

13/10/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

17/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/05/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

FORGED STEEL Y TYPE


STRAINER F800 A105
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Language : E

Consortium Participant or Subcontractor Document No. : 095140009


No of sheet : 4

Power Systems

Sheet :

Plant
Alstom document No :

1 of 4
Client Document No. :

80-L-M-36276

SHA/80/M---M70/DD122

SHA/80/M/---M70/MM/100 Rev. A Page 111 of 130

FORGED STEEL Y
TYPE STRAINER DOUGLAS

F800 A105

STRAINERS
Designed to ANSI B16.34 the strainer bodies are
produced with a superior wallthickness for corrosion
allowance.
Standard stainers are equipped with screens for the
average service of most mediums ( steam, gas, air, oil,
chemicals , ect. ).
The large screen open area ensures an efficent filtering
action with a low pressure drop.
Filtering area to inlet area ratio is larger than 3 to 1 .
Screens area manufactured with perforated plate in the
materials and with the perforation specified in the
relevant tables .
Screens with different peforation ( or wire mesh ) and
materials may be manufactured on request.

INSTALLATION

CORRECT

INCORRECT

CORRECT

INCORRECT

All strainers should be mounted as close as possible to the valve or machinery which they are being installed to protect. It is
important to ensure that the strainer installed with the flow following the same direction as the flow direction arrow cast onto the
strainer body.
For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.
Y strainers should never be installed in vertical pipelines in the upward flow condition. ( see above )

SIZES
1

LIMITING CONDITIONS ( according to ISO 6552 )


CONNECTIONS
Socket Welding

ANSI B16.11

DOUGLAS ITALIA S. p. A.

According to the body rating ( ANSI B16.34 )


F800 ANSI 800

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 112 of 130

Rev.: 5
Date: 21/10/09

Dwg. N.

095140009

Pag. : 1/3

FORGED STEEL Y TYPE STRAINER DOUGLAS

F800 A105
POS.
1

3
4
5

Size
(inches)

DRAIN
PLUG

DESCRIPTION
Body
Screen
Perf. Holes 0.8 mm
+
MESH 40 OPEN 0.4
mm
Plug
Gasket SPW
Drain plug

H1

MATERIALS

SPARES

ASTM A105

AISI 316

ASTM A105
F-GRAPHITE W-316
ASTM A105

Weight
(Kg)

1
1/4 NPT
130
93
140
56
STANDARD PERFORATIONS 0.8mm
Dimension : S, H , H1 , C , SF are in millimeters ( mm)

HOW TO SERVICE
Strainer maintenance should be made at least once year, or whenever the pressure drop is found to be in excess of the normal figures. A
quick clean-up system, to made approximately once a month, is to blow-off small impurities trough the drain-plug (5). It is recommended to
install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: -1- Be
sure that the main line has been shut-off. -2- Remove cover (3) and gasket (4). -3- Withdraw screen (2) an carefully inspect it for damages. If
any hole in the screen is found obstructed, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of
shape, replace it with a new spare one. Never reinstall a broken or distorted screen. -4- Carefully clean the inside of the strainer body. -5Fit a new gasket (4). -6- Install the new screen or the cleaned one (2). Be sure to centre the screen in the upper seat. -7- Put in place cover
(3). Be sure that drain plug (5) is closed. -8- Slowly give pressure to the line, checking for leakages.
9- Write on the strainer body the date of this maintenance operation.

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 5
Date: 21/10/09

SHA/80/M/---M70/MM/100 Rev. A Page 113 of 130

Dwg. N.

095140009

Pag. : 2/3

MODEL

SIZE

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:

F800

SOCKET WELD

009

F800

SOCKET WELD

019

F800

SOCKET WELD

029

F800

SOCKET WELD

040

F800

SOCKET WELD

044

F800

SOCKET WELD

011 (095325)

DOUGLAS REF
CLIENT
CLIENT P.O. No.

TAG. No.:

CLIENT REF.
Q.ty

14QLB33AT201-M70 DS 122
14QLB33AT203-M70 DS 122
14QLB33AT240-M70 DS 122
13QLB33AT201-M70 DS 122
13QLB33AT203-M70 DS 122
13QLB33AT240-M70 DS 122
12QLB33AT201-M70 DS 122
12QLB33AT203-M70 DS 122
12QLB33AT240-M70 DS 122
80-QLC02 AT001 M70DS122
80-QLC03 AT001 M70DS122
80-QLB11 AT201 M70DS122
80-QLB11 AT211 M70DS122
80-QLB11 AT221 M70DS122
80-QLB12 AT201 M70DS122
80-QLB12 AT204 M70DS122
80-QLB12 AT206 M70DS122
80-QLB12 AT208 M70DS122
80-QLB13 AT201 M70DS122
80-QLB21 AT201 M70DS122
80-QLB34 AT212 M70DS122
80-QLB22 AT204 M70DS122
80-QLB22 AT205 M70DS122
80-QLB22 AT206 M70DS122
80-QLB22 AT207 M70DS122
80-QLB34 AT214 M70DS122
80-QLB23 AT201 M70DS122
80-QLB32 AT201 M70DS122
80-QLB34 AT216 M70DS122
80-QLB32 AT209 M70DS122
80-QLB32 AT213 M70DS122
80-QLB32 AT217 M70DS122
80-QLB32 AT221 M70DS122
80-QLB32 AT223 M70DS122
80-QLB32 AT226 M70DS122
80-QLB32 AT234 M70DS122
80-QLB32 AT238 M70DS122
80-QLB32 AT242 M70DS122
80-QLB33 AT201 M70DS122
80-QLB33 AT205 M70DS122
80-QLB33 AT209 M70DS122
80-QLB33 AT233 M70DS122
80-QLB34 AT201 M70DS122
80-QLB34 AT204 M70DS122
80-QLB34 AT207 M70DS122
80-QLB34 AT231 M70DS122
80-QLB34 AT218 M70DS122
80-QLB34 AT241 M70DS122
80-QLB34 AT220 M70DS122
80-QLB34 AT222 M70DS122
80-QLB34 AT224 M70DS122
80-QLB34 AT226 M70DS122
80-QLB34 AT316 M70DS122
80-QLB34 AT321 M70DS122
80-QLB34 AT326 M70DS122
80-QLB34 AT331 M70DS122
80-QLB12 AT203 M70DS122
80-QLB12 AT211 M70DS122
80-QLB12 AT215 M70DS122
80-QLB12 AT219 M70DS122
80-QLB12 AT223 M70DS122
80-QLB34 AT228 M70DS122
80-QLB34 AT230 M70DS122
80-QLB34 AT234 M70DS122
80-QLB22 AT215 M70DS122
80-QLB22 AT219 M70DS122
89-QLB20 AT201 M70DS122
89-QLB20 AT203 M70DS122
80-QLB32 AT248 M70DS122
89-QLB20 AT205 M70 DS122
80-QLB34 AT206 M70DS122
89-QLB20 AT208 M70DS122
89-QLB20 AT209 M70DS122
80-QLB34 AT210 M70DS122
89-QLB20 AT224 M70DS122
89-QLB20 AT228 M70DS122
89-QLB20 AT231 M70DS122
89-QLB20 AT232 M70DS122
89-QLB20 AT234 M70DS122
89-QLB20 AT236 M70DS122
89-QLB20 AT238 M70DS122
89-QLB34 AT311 M70DS122
80-QLB34 AT238 M70DS122
80-QLB35 AT201 M70DS122
80-QLB35 AT203 M70DS122
80-QLB35 AT205 M70DS122
80-QLB35 AT207 M70DS122
80-QLB35 AT209 M70 DS122
80-QLB35 AT211 M70DS122
80-QLB35 AT213 M70DS122
80-QLB35 AT215 M70DS122
80-QLB22 AT208 M70DS122
80-QLB32 AT246 M70DS122

ITEM No.:

3
3
3

16

16

16

JOB NO 095140 - 095325


ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD1

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 5
Date: 21/10/09

SHA/80/M/---M70/MM/100 Rev. A Page 114 of 130

Dwg. N.

095140009

Pag. : 3/3

18/11/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

06/07/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

23/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

17/06/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

27/05/2009

S. GHISONI

VOLPI

M. GHISONI

FOR APPROVAL

FUS

REV

DATE

PREPARED

CHECKED

APPROVED

MODIFICATION

STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

FORGED STEEL Y TYPE


STRAINER F800 A105
Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

Language : E

Consortium Participant or Subcontractor Document No. : 095140010


No of sheet : 2

Power Systems

Sheet :

Plant
Alstom document No :

1 of 2
Client Document No. :

80-L-M-36277

SHA/80/M---M70/DD123

SHA/80/M/---M70/MM/100 Rev. A Page 115 of 130

FORGED STEEL Y
TYPE STRAINER DOUGLAS

F800 A105
STRAINERS
Designed to ANSI B16.34 the strainer bodies are produced with a superior wall
thickness for corrosion allowance.
Standard strainers are equipped with screens for the average service of most
mediums ( steam, gas, air, oil, chemicals , etc. ).
The large screen open area ensures an efficient filtering action with a low
pressure drop.
Filtering area to inlet area ratio is larger than 3 to 1 .
Screens area manufactured with perforated plate in the materials and with the
perforation specified in the relevant tables .
Screens with different perforation ( or wire mesh ) and materials may be
manufactured on request.
Size
(inches)
3

DRAIN
PLUG

H1

3/4 NPT

162

150

280

SPECIAL PERFORATIONS ON REQUEST


Dimension : S, H , H1 , C are in millimeters ( mm)
POS.
1

DESCRIPTION
Body
Screen

MATERIALS
ASTM A105

SPARES

Perf. Plate Holes 6


mm + Mesh40 Open
0.4 mm

AISI 316

3
4
5
6
7

Cover
Gasket SPW
Stud
Nuts
Drain plug

ASTM A105
F-GRAPHITE W-316
ASTM A193 B7
ASTM A194 Gr.2H
ASTM A105

X
X
X
X
X

CORRECT

CONNECTIONS TYPE
BUTTWELD According to ANSI B16.25

INSTALLATION

INCORRECT

CORRECT

INCORRECT

All strainers should be mounted as close as possible to the valve or machinery which they are being installed to protect. It is important to ensure that
the strainer installed with the flow following the same direction as the flow direction arrow cast onto the strainer body.
For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.
Y strainers should never be installed in vertical pipelines in the upward flow condition. ( see above )

HOW TO SERVICE
Strainer maintenace should be made at least once year, or whenever the pressure drop is found to be in excess of the normal figures. A quick clean-up system, to
made approximately once a mounth, is to blow-off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole
to speed-up this operation. For a complete maintenance follow the points herebelow: -1- Be sure that the main line has been shut-off. -2- Remove cover (3) and
gasket (4). -3- Withdraw screen (2) an carefully inspect it for damages. If any hole in the screen is found abstructed, clean it with compressed air and / or any
suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. Never reinstall a broken or distorted screen. -4- Carefully clean
the inside of the strainer body. -5- Fit a new gasket (4). -6- Install the new screen or the cleaned one (2). Be sure to center the screen in the upper seat. -7- Put in
place cover (3). Be sure that drain plug (5) is closed. -8- Slowly give pressure to the line, checking for leakages.
9- Write on the strainer body the date of this maintenance operation.

MODEL

SIZE

MODEL & CONNECTIONS


CONNECTIONS
SCH.

DOUGLAS ITEM No.:


010

F800

BUTT WELD
According to ANSI B16.25

STD

020

030
DOUGLAS REF
CLIENT
CLIENT P.O. No.

CLIENT REF.
TAG. No.:
ITEM No.:
14QLC01AT201-M70 DS 123
14QLC01AT203-M70 DS 123
14QLC02AT201-M70 DS 123
14QLC02AT203-M70 DS 123
13QLC01AT201-M70 DS 123
13QLC01AT203-M70 DS 123
17
13QLC02AT201-M70 DS 123
13QLC02AT203-M70 DS 123
12QLC01AT201-M70 DS 123
12QLC01AT203-M70 DS 123
12QLC02AT201-M70 DS 123
12QLC02AT203-M70 DS 123

JOB NO 095140
ALSTOM POWER SYSTEM S.A.
911772 P12 53003 11370AMD 1

DOUGLAS ITALIA S. p. A.
Loc. Pradaglie Carpaneto (PC) ITALIA
Douglas Italia reserves the right to carry-out any necessary modification without prior notice

SHA/80/M/---M70/MM/100 Rev. A Page 116 of 130

Rev.: 4
Date: 18/11/2009

Dwg. N. 095140010
Pag. : 1/1

Q.ty
4

21/10/2009

S. GHISONI

REV

DATE

PREPARED

VOLPI

FOR APPROVAL

M. GHISONI

CHECKED

APPROVED

MODIFICATION

FUS
STATUS

CLIENT

PROJECT

SHOAIBA POWER PLANT STAGE III


CONTRACT No. 20821102/00
CONSULTANT

CONTRACTOR

SUB CONTRACTOR

Format :

Scale : N.A.

A4
Title :

Language : E

Project :

IS

KKS

Doc Type :

SHA

N/A

N/A

DD

BIMETALLIC THERMOSTATIC
STEAM TRAPS
BF20

Consortium Participant or Subcontractor Document No. : 09532013


No of sheet : 4

Power Systems

Sheet :

Plant
Alstom document No :

1 of 4
Client Document No. :

80L-M-36278

SHA/80/M---M70/DD124

SHA/80/M/---M70/MM/100 Rev. A Page 117 of 130

BIMETALLIC THERMOSTATIC
STEAM TRAPS

BF20

BIMETALLIC THERMOSTATIC
The operating principle is based on a balance between the steam
force ( pressure related ) trying to open the discharge valve and the
bimetal force ( temperature related ) which acts to close it. At saturated
steam temperature the bimetal force keeps the valve closed, while with
subcooled condensate the pressure opens the valve.

MAIN FEATURES

Free air discharge. Suitable on superheated steam. It withstands frost


and waterhammer. Modulating discharge only with condensate.

APPLICATIONS

DISCHARGE CAPACITY

Tracing lines
Marine applications
Turbines
Steam mains
Tanks

Cold water capacities are 2 to 4 times greater than the above .


Safety factor = 1.2 1.5

SIZES

LIMITING CONDITIONS ( according to ISO 6552 )

3/4

Steam Trap rating


PMA: Max allowable pressure
TMA: max allowable temperature
PMO: max differential pressure
TMO: max working temperature

CONNECTIONS
SOCKET WELD

DOUGLAS ITALIA S. p. A.

ANSI B16.11

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 0
Date: 21/10/09

SHA/80/M/---M70/MM/100 Rev. A Page 118 of 130

ANSI 300
50 bar
390C
20 bar
350C

Dwg. N.

095325013

Pag. : 1/3

BIMETALLIC THERMOSTATIC STEAM TRAPS

BF20
POS.
1
2
3
4
5
6
7
8

Size

DESCRIPTION

MATERIALS

Body
Cover
Valve assembly
Gasket SPW
Gasket SPW
Screen
Strainer cap
Bolts

ASTM A105
ASTM A105
STAINLESS STEEL
F-GRAPHITE W-316
F-GRAPHITE W-316
AISI 304
ASTM A105
ASTM A193 B7

(inches)
3/4

SPARES

X
X
X
X

Weight
(Kg)

93

145

60

70

2.5

INSTALLATION
The steam trap can be installed on horizontal or vertical lines. Do not fit the trap upside down since this position will not allow the cleaning of
the strainer. For the same reason the directory of flow on vertical lines must be downwards. For installation with superheated steam, please
conctact our Technical Departement.

HOW TO SERVICE
By installing a new element assemly you can bring the BF steam trap to the as new from factory condition. This operation is carried out in
few minutes without removing the trap from the pipeline. Unscrew the 4 bolts (8) and remove cover (2). Unscrew and remove the element (3).
Clean the insede of the trap and screw in the new element assembly. Fit a new gasket (4) and reinstall cover (2) tightening the bolts (8). To
service the strainer, unscrew cap (7), withdraw screen (6) and clean or replace it. Screwing the cap back in place, always fit a new gasket (5).
The discharge temperature may be adjusted without removing the trap from the line. For informatin about this operation, to be performed only
by qualified personnel, please ask our Techincal Departement.

DOUGLAS ITALIA S. p. A.

Loc. Pradaglie Carpaneto (PC) ITALIA

Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 0
Date: 21/10/09

SHA/80/M/---M70/MM/100 Rev. A Page 119 of 130

Dwg. N.

095325013

Pag. : 2/3

MODEL

BF20

SIZE

MODEL & CONNECTIONS


CONNECTIONS
DOUGLAS ITEM No.:

3/4

DOUGLAS REF
CLIENT
CLIENT P.O. No.

SOCKET WELD

013

CLIENT REF.
TAG. No.:
80-QLC34 AT511 M70DS124
80-QLC34 AT512 M70DS124
80-QLC34 AT513 M70DS124
80-QLC34 AT514 M70DS124
80-QLC34 AT521 M70DS124
80-QLC34 AT522 M70DS124
80-QLC34 AT523 M70DS124
80-QLC34 AT524 M70DS124
80-QLC34 AT531 M70DS124
80-QLC34AT 532 M70DS124
80-QLC34 AT533 M70DS124
80-QLC34 AT534 M70DS124
80-QLC34 AT541 M70DS124
80-QLC34 AT542 M70DS124
80-QLC34 AT543 M70DS124
80-QLC34 AT544 M70DS124
80-QLC34 AT551 M70DS124
80-QLC34 AT552 M70DS124
80-QLC34 AT553 M70DS124
80-QLC34 AT554 M70DS124
80-QLC34 AT561 M70DS124
80-QLC34 AT562 M70DS124
80-QLC34 AT563 M70DS124
80-QLC34 AT564 M70DS124
80-QLC34 AT571 M70DS124
80-QLC34AT572 M70DS124
80-QLC34 AT573 M70DS124
80-QLC34 AT574 M70DS124
80-QLC34 AT581 M70DS124
80-QLC34 AT582 M70DS124
80-QLC34 AT583 M70DS124
80-QLC34 AT584 M70DS124
80-QLC34 AT591 M70DS124
80-QLC34 AT592 M70DS124
80-QLC34 AT593 M70DS124
80-QLC34 AT594 M70DS124
80-QLC34 AT601 M70DS124
80-QLC34 AT602 M70DS124
80-QLC34AT603 M70DS124
80-QLC34 AT604 M70DS124
80-QLC34 AT611 M70DS124
80-QLC34 AT612 M70DS124
80-QLC34 AT613 M70DS124
80-QLC34 AT614 M70DS124
80-QLC34 AT621 M70DS124
80-QLC34 AT622 M70DS124
80-QLC34 AT623 M70DS124
80-QLC34 AT624 M70DS124
80-QLC34 AT631 M70DS124
80-QLC34 AT632 M70DS124
80-QLC34 AT633 M70DS124
80-QLC34 AT634 M70DS124
80-QLC34 AT641 M70DS124
80-QLC34 AT642 M70DS124
80-QLC34 AT643 M70DS124
80-QLC34 AT644 M70DS124
80-QLC34 AT651 M70DS124
80-QLC34 AT652 M70DS124
80-QLC34 AT653 M70DS124
80-QLC34 AT654 M70DS124
80-QLC34 AT661 M70DS124
80-QLC34 AT662 M70DS124
80-QLC34 AT663 M70DS124
80-QLC34 AT664 M70DS124
80-QLC34 AT671 M70DS124
80-QLC34 AT672 M70DS124
80-QLC34 AT673 M70DS124
80-QLC34 AT674 M70DS124
80-QLC34 AT681 M70DS124

ITEM No.: Q. Ty.:

80-QLC34 AT682 M70DS124


80-QLC34 AT683 M70DS124
80-QLC34 AT684 M70DS124
80-QLC34 AT691 M70DS124
80-QLC34 AT692 M70DS124
80-QLC34 AT693 M70DS124
80-QLC34 AT694 M70DS124
80-QLC34 AT701 M70DS124
80-QLC34 AT702 M70DS124
80-QLC34 AT703 M70DS124
80-QLC34 AT704 M70DS124
80-QLC34 AT711 M70DS124
80-QLC34 AT712 M70DS124
80-QLC34 AT713 M70DS124
80-QLC34 AT714 M70DS124
80-QLC34 AT721 M70DS124
80-QLC34 AT722 M70DS124
80-QLC34 AT723 M70DS124
80-QLC34 AT724 M70DS124
80-QLC34 AT731 M70DS124
80-QLC34 AT732 M70DS124
80-QLC34 AT733 M70DS124
80-QLC34 AT734 M70DS124
80-QLC34 AT741 M70DS124
80-QLC34 AT742 M70DS124
80-QLC34 AT743 M70DS124
80-QLC34 AT744 M70DS124
80-QLC34 AT745 M70DS124
80-QLC34 AT746 M70DS124
80-QLC34 AT747 M70DS124
80-QLC34 AT748 M70DS124
80-QLC34 AT749 M70DS124
80-QLC34 AT761 M70DS124
80-QLC34 AT762 M70DS124
80-QLC34AT763 M70DS124
80-QLC34 AT764 M70DS124
80-QLC34 AT765 M70DS124
80-QLC34 AT766 M70DS124
80-QLC34 AT767 M70DS124
80-QLC34 AT768 M70DS124
80-QLC34 AT769 M70DS124
80-QLC34 AT781 M70DS124
80-QLC34 AT782 M70DS124
80-QLC34 AT783 M70DS124
80-QLC34 AT784 M70DS124
80-QLC34 AT785 M70DS124
80-QLC34 AT786 M70DS124
80-QLC34 AT787 M70DS124
80-QLC34 AT791 M70DS124
80-QLC34 AT792 M70DS124
80-QLC34 AT793 M70DS124
80-QLC34 AT794 M70DS124
80-QLC34 AT795 M70DS124
80-QLC34 AT796 M70DS124
80-QLC34 AT797 M70DS124
80-QLC34 AT801 M70DS124
80-QLC34 AT802 M70DS124
80-QLC34 AT803 M70DS124
80-QLC34 AT804 M70DS124
80-QLC34 AT805 M70DS124
80-QLC34 AT806 M70DS124
80-QLC34 AT807 M70DS124
80-QLC35 AT811 M70DS124
80-QLC35 AT821 M70DS124
80-QLC35 AT831 M70DS124
80-QLC35AT841 M70DS124
80-QLC35AT851 M70DS124
80-QLC35 AT861 M70DS124
80-QLC35AT871 M70DS124

19

138

JOB NO 095325
ALSTOM POWER SYSTEM S.A.
911772 REV. 2

DOUGLAS ITALIA S. p. A. Loc. Pradaglie Carpaneto (PC) ITALIA


Douglas Italia reserves the right to carry-out any necessary modification without prior notice

Rev.: 0
Date: 21/10/09

SHA/80/M/---M70/MM/100 Rev. A Page 120 of 130

Dwg. N.

095325013

Pag. : 3/3

Manual
Sheet
Rev.

Loc. Pradaglie 29013 Carpaneto (PC) ITALIA

No.: 6E161114
: 1/5
: 1

MAINTENANCE MANUAL
BALL FLOAT LIQUID DRAINER
mod.

GT,GV,GX,GY

INDEX
-----------------------------------------------------------------------------------------------------Paragraphs
1)
2)
3)
4)
5)
6)

DESCRIPTION AND OPERATING PRINCIPLE.


ASSEMBLING.
START UP.
MAINTENANCE.
NAMEPLATE INFORMATION.
PROBLEMS/SOLUTIONS.

-------------------------------------------------------------------------------------------------------

SHA/80/M/---M70/MM/100 Rev. A Page 121 of 130

Manual
Sheet
Rev.

Loc. Pradaglie 29013 Carpaneto (PC) ITALIA

No.: 6E161114
: 2/5
: 1

1) DESCRIPTION AND OPERATING PRINCIPLE.


The liquid drainer is an equipment used to drain the condensate that is produced by the line. It works like a valve that
opens automatically as the condensate enters and closes as the gas (air). In the ball float liquid drainer the opening of
the discharge orifice is due to the floating force produced by the condensate.
Figure 2 describes the various parts of the liquid drainer and its operating principle.
The ball float (pos 7) is connected to the discharge valve (pos 5) by a lever. The ball float is normally placed (due to the
gravity ) in the lower position of its working movement so that the discharge valve is kept closed.
With these conditions the gas can not leave the trap , since the valve seat is always placed behind the liquid level and
allows to keep an hydraulic guard.
As the condensate enters the body trap (pos 1) it rises the float and opens the valve overcoming the pressure acting on
it. Once the condensate has been discharged, the ball float returns to the beginning position closing the valve.

2) ASSEMBLING
a)

b)

c)

d)

e)
f)

The connection with the main line (in, out) and the secondary lines (e.g. drain) can be welded, flanged or screwed.
The reference drawing quote the positions, dimensions and the kind of connections with the relevant norm. Welding
have to be performed by qualified personnel and following qualified procedures .
Check that the liquid drainer is connected to the line, following the flow direction, that is marked on the body by an
arrow.(Figure 1).The correct positions of the liquid drainer assembled on the line are showed in Figure 1.The liquid
drainer will be set for horizontal or vertical connections, in both cases the body with the ball float should be placed as
per fig. 1(make reference to UP marking) in order to allow the correct lever movement.
Check the dimensions of the liquid drainer allow to disassemble the cover and to withdraw the internal parts during
the maintenance. Consider the possibility to disconnect the liquid drainer from the line during the maintenance
performing. It will be possible to perform the maintenance using a by pass without using the area of the line where
the strainer is connected..
We suggest to consider the possibility to assemble a strainer upstream the liquid drainer to prevent the obstruction
of the internal part. The installation of a flow indicator downstream the liquid drainer would allow to check the correct
operation.
If the liquid drainer has been placed on a line that could freeze during the stop, it is necessary to employ a drain
plug (Figure 2) (pos..11) in order to discharge the condensate kept on the drainer body.
Check that the line is supported and can stand any possible expansion and vibration in order to avoid to charge the
liquid drainer too much. Verify in the nameplate data (par. 5) on the body are suitable to the test and operative
conditions of the line where it will be installed. Verify if the flow and the environment characteristics are suitable to
the kind of drainer materials. If there is some doubt about the suitability of the flow for the liquid drainer material
consult the supplier. This is important in order to keep the CE conformity (when CE mark is required).

VERTICAL CONNECTIONS
IN

HORIZONTAL CONNECTIONS

IN
UP

UP
IN

DOUGLAS

OUT

DOUGLAS

IN
OUT

OUT

SHA/80/M/---M70/MM/100 Rev. A Page 122 of 130

Fig.1

Manual
Sheet
Rev.

Loc. Pradaglie 29013 Carpaneto (PC) ITALIA

No.: 6E161114
: 3/5
: 1

3) START-UP
After the liquid drainer assembling gradually bring the line to the operating conditions. The start up has to be performed
avoiding any water hammer, in order to keep both the liquid drainer and the line functionality. After any new line start up
is advisable the screen cleaning. During the start up phase check there are no leaks in the connections between the
body and the bonnet and also between the liquid drainer connections and the line.

4) MAINTENANCE
Maintenance is performed by disassembling the body from the cover to carry out the internal cleaning. Normally,
maintenance is necessary when the problems mentioned at par. 7 take place. It is not possible to establish which time
space has to run between one operation and following one.
During the maintenance, check both the inside and the outside of the liquid drainer body to verify, after a proper cleaning,
the component integrity, with particular attention to any corrosion spots that have to be removed.

POS.
1
2
3
4
5
6
7
8
9
10
11

condensate

DESCRIPTION
Body
Cover
Gasket
Seat
Valve
Lever
Ball float
Plug
Bolts
Vent plug
Drain plug

SPARES

X
X
X
X
X

Fig. 2

Before starting it is necessary to check the liquid drainer inside pressure has been completely dissipated and
the body temperature has reached the environmental values. Furthermore check the kind of the fluid that passes
inside the liquid drainer in order to be fitted during the operation with adequate individual protective device.
The maintenance different steps (Fig. 2) are listed here below.
a)
b)
c)

d)

e)
f)
g)
h)

Unscrew the bolts between body and cover (2) and remove the body(1). Extract the gasket(3).
Clean the internal part of the body, and check it.
If it is necessary to replace the ball float(7)
Unscrew the nuts that connect the ball float with lever (6)
Remove the ball float (7) and replace it with a new one.
If it necessary to replace or clean the discharge valve (4).
Remove the ball float (7) and its lever(6) and valve (5).
Unscrew the valve(4) ,remove the valve (4) and the its gasket.
Perform the valve cleaning or replacement .
Re-assembly all elements.
Set a new gasket (3) and re assemble the body (1) by the bolts (9).
Screw the bolts (9). Tightening has to be performed by three different steps, 50%,80%,100% of the torque.
Slowly give pressure to the line, checking for the body/cover seal (see par. 3).
Write the date of this maintenance operation

SHA/80/M/---M70/MM/100 Rev. A Page 123 of 130

Loc. Pradaglie 29013 Carpaneto (PC) ITALIA

Manual
Sheet
Rev.

No.: 6E161114
: 4/5
: 1

5) NAMEPLATE INFORMATIONS

Here below are written the various mark meaning stamped on the nameplate attached to the body strainers.
The nameplate figure and the relevant datas value are quoted by the relevant reference drawing.
1
2
3
4
5
6

Model.
Pmo (bar)
PT (bar)
Tmo (C)
P (bar)
ND

DOUGLAS ITALIA liquid drainer model identification .


Maximum allowable pressure inside the liquid drainer body.
Allowable hydraulic test pressure
Maximum allowable working temperature
Maximum allowable upstream-downstream pressure drop to allow the drainer performance
Nominal pipe size and type of connection.
Liquid drainer body rating in accordance with ASME B16.34 norm. It is the maximum allowable
pressure inside the body with reference to the material (described at point 8) and to the reference
temperature .The rating tables for the various materials are given on Rating table manual N.
7 Class
6E161115-E. Check that the working conditions are in accordance both with the limiting
conditions mentioned at point 2,4 and 5 and with the values indicated in the reference rating
tables.
8 Body mat..
Liquid drainer body material identification.( e.g. ASTM A216 WCB )
9 cat.
Fluid PED category (1)
10 Fluid gr.
PED fluid group (1)
11 Man. year
Manufacturing year .
12 S.N.
DOUGLAS ITALIA Serial number
13 CE
CE mark with identifying number of the authorized institution (1)
14 Mark
Tag. number
(1) These marks are indicated only when CE is required.

The following information to be included on the nameplate.:


- Tag. No ( e.g. R240-STP-2001 )
- End Connection ( e.g. NPS 3 )
- ASME Class Rating of End Flange ( e.g. ASME Cl.300 )
- Float Material Specification ( e.g. UNS-30400 )
See Doc. V-216G-318-A-251

SHA/80/M/---M70/MM/100 Rev. A Page 124 of 130

Manual
Sheet
Rev.

Loc. Pradaglie 29013 Carpaneto (PC) ITALIA

No.: 6E161114
: 5/5
: 1

6) RATING TABLE
A 182 F316 A 351 CF8M

A 105 A 216 WCB


C

Working pressure ( bar ) by classes

150

19.7
51.0
-29 38
93
17.9
46.5
149
15.9
45.2
204
13.8
43.8
260
11.7
41.4
316
9.7
37.9
343
8.6
36.9
371
7.6
36.9
399
6.6
34.8
427
5.5
28.3
454
4.5
18.6
482
3.4
11.7
510
2.4
7.2
538
1.4
3.4
566
593
621
649
677
704
732
760
788
816
A 105 , A 216 WCB : permissible ,but not recommended for
prolonged usage above about 454C

Working pressure ( bar ) by classes

300

150

300

19.0
49.6
-29 38
93
16.5
42.7
149
14.8
38.6
204
13.4
35.5
260
11.7
33.1
316
9.7
31.0
343
8.6
30.7
371
7.6
29.6
399
6.6
29.3
427
5.5
28.6
454
4.5
27.9
482
3.4
27.2
510
2.4
26.5
538
1.4
25.2
566
1.4
24.8
593
1.4
22.4
621
1.4
19.0
649
1.4
14.1
677
1.4
12.4
704
1.4
9.7
732
1.4
7.2
760
1.4
5.2
788
1.4
4.1
816
1.0
2.8
For welding end. Flanged end ratings terminate at 538C

7) PROBLEMS/SOLUTIONS.

TROUBLE

CONSEQUENCE

Leak on the body/bonnet


connection

The fluid leaves the Liquid drainer


from the body/bonnet connection

The Liquid drainer does not


open, or it opens insufficiently

The sight glass receives poor


or no flow.

AMENDMENT

Check the tightening torque and assemble, if


necessary, a new gasket making reference
to the instructions given at par. 4

Check the inlet and the outlet pressure do


not overcome the maximum allowable
pressure.
The ball float is perforated or twisted by a
water hammer.
The discharge valve is obstructed by dirt.
Clean the valve and ,if necessary, assemble
a strainer upstream the liquid drainer.
The discharge valve ruined Replace as per
par. 4
The discharge valve (pos4) is obstructed by
dirt and it does not close.

The Liquid drainer does not


close

Passage of gas at the out of


the liquid drainer

SHA/80/M/---M70/MM/100 Rev. A Page 125 of 130

Loc. Pradaglie 29013 Carpaneto (PC) ITALY

Workbook No.:4C091406-E
Page
: 1/5
Rev.
: 0

Y-FILTERS USE AND MAINTENANCE WORKBOOK

S
LA
UG
DO

S
LA
UG
DO

Cast Y-filters

Forged Y-filters

CONTENTS
-----------------------------------------------------------------------------------------------------1)
2)
3)
4)
5)
6)

DESCRIPTION.
INSTALLATION.
STARTING.
MAINTENANCE.
PLATE DATA.
DRAWBACKS / CORRECTIONS.

-------------------------------------------------------------------------------------------------------

SHA/80/M/---M70/MM/100 Rev. A Page 126 of 130

Loc. Pradaglie 29013 Carpaneto (PC) ITALY

Workbook No.:4C091406-E
Page
: 2/5
Rev.
: 0

1) DESCRIPTION
Y-filter is a component suitable for the mechanical removal (filtering) of impurities contained in the fluid going
through it (liquid, gas). From the body inside, the fluid is conveyed into the cartridge (Pict. 1) realized with
perforated sheet and/or net, where it is filtered and then carried back into the line. The filter body can be
made by casting or forging and the body/cover coupling can be bolted or threaded. Picture 1 shows the
standard configuration of Y-filters for the three models. The reference drawing will show the parts with list of
materials and detailed dimensions.
Pos.
1
2
3
4
5
6
7

Description
Body
Filtering component
Cover (bolted or threaded)
Cover body gasket
Bleeding cap
Tie rods
Nuts

2) INSTALLATION
a) The connection to the main and secondary lines (ex. bleeding) can be made by socket or butt welding,
flanging or threaded connection. The reference drawing shows the provisions concerning the connection
type and size.
b) Make sure to connect the filter with the line according to the flow direction marked by an arrow on the
body. The correct positions of the filter assembled on the line are shown in pict.2. Make sure that the
bleeding is turned to the bottom part of the cover so as to allow, when required, the complete evacuation
of the fluid from the filter. The linkage of all filter connections with the different lines shall be
executed and checked by a qualified staff so as to assure a correct alignment and resistance of
the joint to pressure. For large-sized filters, we suggest to place the body branch sideways so as to be
able to remove the cover with suitable lifting means (see picture 2 c).
c) Check that the space occupied by the filter assembled on the line allows the removal of the cover and
the cartridge for the maintenance. The reference drawings show the observance distance.
d) For large-sized filters, arrange things so that you can use suitable lifting devices for the handling and
positioning of the component on the line. Refer to the enclosed drawing for the filter weight.
e) Check that the plate data (paragraph 5) on the filter body fit the working and test conditions of the line
where the component will be assembled. Make also sure that the characteristics of the line fluid and the
external environment are compatible with the filter materials. The reference drawing shows the
manufacture materials and parts list. For information, see table no. 4D081038-E. When in doubt about
the compatibility of the line fluid with the filter material, apply to the supplier in order to keep compliance
with the EC mark.
f) Check that the line on which the filter will be placed is independently supported and able to absorb any
thermal expansion and vibration so as not to surcharge the component and its connections.
g) Provide for the possibility to disconnect the filter from the line for the maintenance. With the bypass
solution, the maintenance can be executed without insulating the plant part where the filter is positioned.

3) STARTING
After assembling the filter, take the line to the working conditions slowly. This operation shall be made by
degrees (avoid ram strokes) so that the rises in pressure, temperature and delivery dont prejudice the
component and line integrity. When starting a new plant you should clean the filtering component. During the
starting phase, check the absence of leaks between the joints of body/cover and connections/line.

SHA/80/M/---M70/MM/100 Rev. A Page 127 of 130

Loc. Pradaglie 29013 Carpaneto (PC) ITALY

Workbook No.:4C091406-E
Page
: 3/5
Rev.
: 0

4) MAINTENANCE
The maintenance consists in disassembling the cover and taking the filter cartridge away in order to clean
the cartridge from impurities. It is not possible to state how many times you have to execute this operation,
as it depends on many factors (working conditions of the line, fluid type and consistency, degree and
quantity of impurities to be stopped, etc.). Anyhow, the progressive clogging of the cartridge will cause a
greater loss of charge produced by the filter. Consequently, the maintenance shall be executed when the
loss of charge becomes incompatible with the working conditions of the line or when the maximum pressure
that can be stood by the filter cartridge is exceeded. The connection of the filter with differential pressure
detectors would allow to monitor this situation. Upon request, the filter can be provided with housings for the
aforesaid detectors.

During the maintenance, check the external and internal side of the filter body; after a proper cleaning, check
its integrity and, in particular, any corrosive phenomena that shall be removed.
Anyhow, the check and maintenance of the filter shall be executed at least once a year by a qualified
staff, recording the date. First of all, make sure that the inner pressure of the filter is completely
dissipated and the body temperature falls within ambient values. Make also sure of the fluid typology
so as to provide yourself with suitable personal protection devices during the operations.
Below you can find the maintenance steps (see reference drawing)
a) Cut off the filter from the line pressure. Make sure that the inner pressure of the filter body is completely
discharged and the component temperature falls within ambient values.
b) Bleed the line. Unscrew the bleeding cap (5) or open the drainage valve (if any) and drain any residual
fluid from the inside of the filter body, then disconnect the draining line (if any).
c) For the model with bolted body/cover, unscrew the nuts (7) and remove the cover (3). For the model with
threaded body/cover, unscrew the cover (3).
d) Take away the gasket (4) and the filtering component (2).
e) Clean the filtering component (2) from the impurities and check its integrity (in case of breaks or
deformations of its surface, it is necessary to change it).
f) Clean and check the inside of the filter body. Put in a new gasket (4).
g) Put in the filtering component (2) and the cover (3) and pay attention to position it correctly inside the
body housing (1) and the cover housing (3) (see picture 1).
h) Tighten the nuts with the torque mentioned in table no.4D081039-E referred to the nominal diameter and
material of tie rods. The diameter and material of tie rods are mentioned in the corresponding reference
drawing. The tightening shall be carried out in three stages: 50, 80 and 100% of the torque stated.
i) Screw down the bleeding cap (5) or connect again the drainage with the draining line.
j) Put slowly the line under pressure and check the seal between body and cover (see paragraph 3).
k) Record the date of the operations executed.

SHA/80/M/---M70/MM/100 Rev. A Page 128 of 130

Workbook No.:4C091406-E
Page
: 4/5
Rev.
: 0

Loc. Pradaglie 29013 Carpaneto (PC) ITALY

5) PLATE DATA
The value of these data is mentioned on the component plates and the corresponding reference drawings.
PS (bar)
PT (bar)
TS (bar)
ND

Maximum allowable pressure inside the filter body at a temperature of 37C.


Hydraulic test pressure.
Minimum and maximum allowable temperature for the filter.
Nominal diameter at the filter mouth.
Filter rating according to ASME B16.34 standard. It is the maximum allowable pressure inside
Class
the filter body depending on the reference temperature and material.
Fluid group Fluid group (stated in the PED directive) the filter has been designed for. (1)
Body/scr..
Mark of the material of the filter cartridge and body.
Information about the filter cartridge perforation. This value represents the minimum size of the
Screen per.
impurities that can be stopped by the filter.
Man. yea..
Year of manufacture.
S. N.
Serial number.
Identifying mark required by the customer. If, for lack of space, the identifying mark cannot be
Mark
put in the relevant space, itll be marked on a plate fastened onto the filter.
CE
EC mark with identifying number of the authorized institution (1)
(1) These data are added only when the EC certification is required.

6) DRAWBACKS / CORRECTIONS
DRAWBACK

EFFECT

CORRECTION

Leakage from body/cover


coupling

Fluid leakage from the


coupling

Check the tightening torque in accordance with


instructions of paragraph 4.
If the drawback persists, put in a new gasket
according to paragraph 4.

Filter cartridge clogging

Excessive loss of
charge produced by the Clean the filter cartridge; see paragraph 4.
filter

Broken or deformed, out-ofseat filter cartridge.

No filtration

Replace the filter cartridge; see paragraph 4.

SHA/80/M/---M70/MM/100 Rev. A Page 129 of 130

Workbook No.:4C091406-E
Page
: 5/5
Rev.
: 0

Loc. Pradaglie 29013 Carpaneto (PC) ITALY


1

7
2

4
3
2

5
2

Cast Y-filter
Bolted body cover

Forged Y-filter
Bolted body cover

4
5
3

1
4

6
4

Forged Y-filter
Threaded body cover

U
DO
AS
GL

S
LA
UG
DO

S
LA
UG
DO

(a)

S
LA
UG
DO

Cast Y-filter
Bolted body cover

AS
GL
U
DO

Forged Y-filter
Bolted body cover

AS
GL
U
DO

Forged Y-filter
Threaded body cover

(b)

(c)
2

SHA/80/M/---M70/MM/100 Rev. A Page 130 of 130