You are on page 1of 2

Plastic industrial boxes

n Characteristics - IP 55 - IK 07 boxes

n Characteristics - IP 55 - increased depth boxes

Box:
Cover:

Operating temperature: - 20 C to + 50 C
Self-extinguishing: 750 C (EN 60695-2-11)
For indoor use

- IP 55: polypropylene
- opaque: polypropylene (except 0 359 80: polycarbonate)
- transparent: polycarbonate
Operating temperature: - 25 C to + 40 C
Self-extinguishing: 750 C (EN 60695-2-11)
For indoor use

n Dimensions
Boxes

n Dimensions
C
E

212

233
G

A
N

80

(1)

Mounting plate

140

144

B
M
R

200

Boxes

Cat.No 0 921 22

183
(1) (1)

Usable area 3.7 dm2

132.6
60.7 79.6

162

146
L

Cat.No 0 350 58

1: Fixing for accessories (rail, mounting plates)

140 85

81

56

18

67

70

0 359 30

150 150 81

56

18

67

54

70 120 103 102

87 106 106 84

0 359 40

175 130 81

56

18

67

79

50 100 128 112

88

0 359 50

200 160 94

69

18

80 104 50 130 153 137 112 116 156 94

0 359 60/61

240 190 94

69

18

80 144 80 160 193 175 142 146 196 124

0 359 70/71

290 190 94

69

18

80 194 80 160 243 226 142 146 246 122

0 359 80

332 262 132 97

65 120

51 106

R
-

86 131 64

4.5

211
4.5

282

321

90

9.2

5.7

94

20

34

155

165

Cat.No 0 922 84

45

50

148.5
3.8
62
92

182
Usable area 3.5 dm2
Weight: 1.08 kg

27 116 220 160 222 276 248 198 200 260 150

Cat.No 0 921 28

246

0 359 00

342

Accessories fixing
(4 mm screw supplied)

273

Box fixing
(mm)

Dimensions (mm)
Cat.Nos

R23
94

11

146

251
52

Cat.No 0 921 38

Usable area 5.5 dm


Weight: 2.3 kg

54
41.8

78

271

82

190

37
50
116

121
95
80

121
95
80

12.3
2

60

47
116

Metal mounting plates

B
D

A
C

Cat.Nos

0 358 10

114

114

106

106

0 358 11

94

139

86

131

0 358 12

124

164

116

156

0 358 13

154

204

146

196

0 358 14

154

254

146

246

0 358 15

211

271

200

260

Maximum length of terminals


Box dimensions (mm)

Number of holes

130 x 130 x 74

155 x 110 x 74

13

180 x 140 x 86

13

220 x 170 x 86

22

310 x 240 x 124

28

563

Flexible conduits

Flexible conduits

n Characteristics
Wire crosssection in mm2

Occupation crosssection in mm2

1.5

8.55

2.5

11.9

15.2

22.9

10

36.32

Shock resistance: 2 joules at - 5 C


Min operating t: - 5 C
Max operating t: + 60 C
Flush-mounted in certain cases before construction
of the masonry

16

50.3

exterior
(mm)

interior
(mm)

thickness
(mm)

25

75.4

16
20
25
32
40
50

10.7
14.1
18.3
24.3
31.2
39.6

2.65
2.95
3.35
3.85
4.40
5.20

35

95.03

High impact with draw wire (ICTA 3422)

50

132.7

Shock resistance: 6 joules at - 5 C


Min operating t: - 5 C
Max operating t: + 90 C
IK 08
Surface mounting not recommended outside
Suitable for prefabricated concrete

70

176.7

95

227

120

283.5

150

346.3

6 510 16

6 512 16

Accessories for conduits p. 568


Flame-retardant
Conform to standard EN 61386-21 and IEC 61386-2
Crush resistance: 750 Newtons
Supplied wrapped in film, the coil acts as a pay-out reel
The various diameters are identified by coloured ties
Surface-mounting or flush-mounting
Pack

100
100
100
50
50
50

100
100
100
50
50
50
25

Cat.Nos

6 510 16
6 510 20
6 510 25
6 510 32
6 510 40
6 510 50

6 512 16
6 512 20
6 512 25
6 512 32
6 512 40
6 512 50
6 512 63

Medium impact (ICA 3321)

exterior
(mm)

interior
(mm)

thickness
(mm)

16
20
25
32
40
50
63

10.7
14.1
18.3
24.3
31.2
39.6
52.6

2.65
2.95
3.35
3.85
4.40
5.20
5.20

Number of external of ducts to be used


Conductor*
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5

Flexible*
16
16
20
20
16
20
20
25
20
20
25
25
20
25
32
32
25
32
32
40
32
32
40
40
32
40
50
50
40
50
50
63
50
50
63
63
50
63
63

Rigid*
16
16
16
16
16
16
20
20
16
20
20
25
20
20
25
25
20
25
32
32
25
32
32
40
32
40
40
50
32
40
50
50
40
50
63
63
50
63
63

63
63

63
63

63

63
63

63

63

* Based on H 07 V - U/R

n Use
Surface-mounting or flush-mounting for electrical installations
in residential buildings
Rigid
reinforced

Flexible
and rigid

Exterior

Surfacemounting

Flushmounting

Reinforced
flexible

Interior
Before
construction

Walls
Floors

After construction
Possible

Not recommended

Prohibited

Reinforced flexible conduit with wire puller: flexible annular,


suitable for prefabricated concrete
Annular flexible conduit: flexible, without wire puller
Rigid conduit with integrated sleeves: rigid, smooth, without wire puller

564

You might also like