For finding the faulty managed object use command


RXASP: MO=RXOTG- tg$;
This alarm list contains various alarms like BTS INT UNAFFECTED, BTS
INTAFFECTED, PERMANENT FAULT, some alarms can be removed by
usingBLOCK/DEBLOCK commands.7. For finding fault code on particular
managed object (mo) use
RXMFP: MO=mo$;
This command shows fault code class and code some description is bellow

IF mo$ is RXOCF then FAULT CODE IS


2A-33 RX diversity lost2A-8 VSWR limits exceeded2A-57 RX PATH IMBLANCE
(VSWR)2A-39 RX cable disconnected (Related faults: RXORX 1B:9 - RX
cabledisconnected)2A:7 RXDA amplifier current faults (CDU FAULTY Need
replacement
)
2A-21 internal power capacity reduced (PSU unit faulty or power off)2A-41
lost communication to TRU2A:23 Climate capacities reduced (Check fans
and the Fan Control Unit)2A:9 Power limits exceeded (Related faults: RXOTX
1B:2 TRU faulty needreplacement)

If mo$ is RXOTRX then fault code is


1A-13 TX saturation (TRU FAULTY Need replacement)2A-12 TX output power
limits exceeded (Related faults: TX 1B:13)block/deblock unit if not work
Change TRU2A-13 TX saturation (Related faults: TX 1B:14 - TX
saturation)block/deblock unit if not work Change TRU2A:25 TX max power
restricted block /deblock unit if not work Change TRU2A:43 internal
configuration fail block /deblock unit if not work Change TRU2A:42 Hardware
IDB inconsistent check combiner chip & then IDBAny alarm found other than
mentioned above on any manage object then pleaseconsult with MSC
Gorakhpur
8. FOR replacement of TRU
First get local mode on TRU by pressing Local /Remote button on TRU2
nd
power off the TRU3
RD
with the help of T10 Screw driver open the 2 pair screw on upper/lowerend
of unit4

th
replace the faulty unit with new one5
th
power on and wait until Local Lamp get constant glow6
th
again get remote status by pressing Local /Remote button on TRUPage
2
of
4

Wait for operation condition by 5minute if not operational block/deblock


fromBSC if not work contact with MSC Gorakhpur
Same processors adopt for CDU replacement (except Local/remote)Caution
must be taken for wiring of units
Tools (basic) used for hardware replacement are-32 wrench8/9 wrenchNoze
pliersT10T8
For analysis of TCH BLOCKING
1. Find that site working in full configuration by using commandRXCDP:
MO=RXOTG-tg$; (ALL mo must be configured)
If any BLOCKED found then use command
RXASP: MO=RXOTG-tg$; (to find the all alarm and reason of block)IF LOCAL
MODE found than try to make REMOTE otherwiseCheck the fault code by
commandRXMFP:MO=mo$; (to find the exact fault code to make decision
thathardware if faulty or not if hardware is faulty and need replacement
thenbook the fault to ericsson and if the hardware is not faulty
theBLOCK/DEBLOCK to make unit operational )
If any mo not block then check the half rate is on or off
For checking half rate use commandRLDHP: CELL=cell; (DHA=ON)If DHA not
ON use command to on itRLDHC: CELL=cell, DHA=ON;If traffic is more than
for witch site is configured (as erlang B table ) thenincrease the value of half
rate by using commandRLDHC: CELL=cell, DTHAMR=100,
DTHNAMR=100;Erlang B tableTRU (Per sector) Traffic that supported on full
rate1 2.2E2 8.0E3 14.5E4 21.4E5 28.5E6 35.8E7 43.1E8 50.5E
If none of the above case so new BTS is required to release congestion
Page
3

of
4

For analysis of TCH DROP/CALL DROP


1. find alarm of RXOCF i.e VSWR or RX diversity lost if present the get rectify
it2. find alarm of TRU if any alarm the get rectified3. use command
RLCRP:CELL=cell;
and in output see the ICM band must be 1to 3 if ICM band is 4-5 then
correspond TRU is faulty get replacement (for finding thecorresponding TRU
use BPC no. in RLCRP: CELL=cell; and RXCDP: MO=RXOTG-tg$)4. check
handover report form Network quality report that is handover isproperly
work5. define handover if not present in neighbor list using the command
RLNRP: CELL=cell, CELLR=all;
( for neighbor list)
RLNRI: CELL=cell, CELLR=cellr;
(for cellr add in neighbor list)