You are on page 1of 64

Axial Piston Pumps

Series PVplus
Variable Displacement

parker.com/pmde

Catalogue HY30-3245/UK

Contents

Axial Piston Pumps


Series PVplus

Contents Page
Introduction and general Information...............................................................4
Technical Data.................................................................................................5
Ordering Code.................................................................................................6
Pressure Controls..........................................................................................18
Remote Pressure Controls............................................................................20
Load Sensing Controls..................................................................................22
Horse Power/Torque Controls........................................................................26
Performance Curves......................................................................................30
Electronic P/Q Controls.................................................................................32
Efficiency and Case Drain Flows...................................................................34
Performance Curves and Case Drain Flows PV 360.....................................39
Accessories Control......................................................................................40
Proportional pressure relief valve PVACRE*.................................................42
Accessories Control......................................................................................43
Dimensions....................................................................................................44
Control Dimensions.......................................................................................56
Electronic Module PQDXXA..........................................................................60
Thru Drive, Mounting Kits..............................................................................61
Thru Drive, Flange Load Limitation...............................................................62
Multiple Pump Combinations - Maximum Moment........................................62
Thru Drive, Shaft Load Limitations................................................................63

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Catalogue HY30-3245/UK

Introduction

Axial Piston Pumps


Series PVplus
Technical Features

With thru drive for single and multiple pumps


Swash plate type for open circuit

Low noise level


Fast response
Service-friendly
High self-priming speed
Compact design
Thru drive for 100% nominal torque

General Information
Fluid recommendations
Premium quality hydraulic mineral fluid is recommended,
like HLP oils to DIN 51524, part 2. Brugger- value
has to be 30 N/mm2 minimum for general application
and 50N/mm2 for heavily loaded hydraulic equipment
and fast cycling machines and/or high dynamic loads,
measured in accordance with DIN 51 347-2. See also
Document HY30-3248/UK Parker Hydraulic Fluids.

Recommended cleanliness for maximum component


life and functionality: Class 18/16/13, according to ISO
4406:1999
Seals
Check hydraulic fluid specification for chemical resistance
of seal material.
Check temperature range of seal material and compare
with max. system and ambient temperature.

Viscosity
The normal operating viscosity should range between
16 and 100 mm2/s (cSt). Max. start-up viscosity is
800 mm2/s (cSt).

Filtration
For maximum pump and system component functionality and life, the system should be protected from
contamination by effective filtration.
Fluid cleanliness should be in accordance with ISO
classification ISO 4406:1999. The quality of filter
elements should be in accordance with ISO standards.
General hydraulic systems for satisfactory operation:
Class 20/18/15, according to ISO 4406:1999

N Nitrile (FKM shaft seal)


B Nitrile (NBR shaft seal)
V FKM (FKM shaft seal)
W Nitrile (PTFE shaft seal)
P FKM (PTFE shaft seal)

-25+90 C
-40+90 C
-25+115 C
-30+90 C
-25+115 C

Note: The highest fluid temperature will be at the drain


port of the pump, up to 25 C higher than in the
reservoir.

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Catalogue HY30-3245/UK

Technical Data

Axial Piston Pumps


Series PVplus

PV016 PV020 PV023 PV028 PV032 PV040 PV046


Frame size
1
1
1
1
2
2
2
16
20
23
28
32
40
46
Max. Displacement
[cm3/rev.]
Output flow at 1500 rpm
[l/min]
24
30
34,5
42
48
60
69
Nominal pressure pN
[bar] 350
350
350
350
350
350
350
Min. outlet pressure
[bar]
15
15
15
15
15
15
15
[bar] 420
420
420
420
420
420
420
Max. pressure pmax at 20% working cycle1)
Case drain pressure, continuous
[bar] 0.5
0.5
0.5
0.5
0.5
0.5
0.5
Case drain pressure, max. peak
[bar] 2.0
2.0
2.0
2.0
2.0
2.0
2.0
Min. Inlet pressure, abs.
[bar] 0.8
0.8
0.8
0.8
0.8
0.8
0.8
Max. Inlet pressure
[bar]
16
16
16
16
16
16
16
Input power at 1500 rpm and 350 bar
[kW] 15.5
19.5
22.5
27.5
31
39
45
Max speed at 1 bar, abs, inlet pressure
[rpm] 3000 3000 3000 3000 2800 2800 2800
Min. speed
[rpm] 400
400
400
400
400
400
400
2
Moment of inertia
[kgm ] 0.0017 0.0017 0.0017 0.0017 0.0043 0.0043 0.0043
Weight
[kg]
19
19
19
19
30
30
30

Frame size
Max. Displacement
[cm3/rev.]
Output flow at 1500 rpm
[l/min]
Nominal pressure pN
[bar]
Min. outlet pressure
[bar]
[bar]
Max. pressure pmax at 20% working cycle1)
Case drain pressure, continuous
[bar]
Case drain pressure, max. peak
[bar]
Min. Inlet pressure, abs.
[bar]
Max. Inlet pressure
[bar]
Input power at 1500 rpm and 350 bar
[kW]
Max speed at 1 bar, abs, inlet pressure
[rpm]
Min. speed
[rpm]
Moment of inertia
[kgm2]
Weight
[kg]

PV063 PV080 PV092 PV140 PV180 PV270 PV360


3
3
3
4
4
5
6
63
80
92
140
180
270
360
94.5
120
138
210
270
405
540
350
350
350
350
350
350
350
15
15
15
15
15
15
15
420
420
420
420
420
420
420
0.5
0.5
0.5
0.5
0.5
0.5
0.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
0.8
0.8
0.8
0.8
0.8
0.8
0.8
16
16
16
16
16
16
16
61.5
78
89.5
136
175
263
350
2800 2500 2300 2400 2200 1800 1750
400
400
400
400
400
400
400
0.018 0.018 0.018 0.030 0.030 0.098 0.103
59
59
59
90
90
172
180

1) Special control options required.

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 1

PV

R 1 K 1 T 1 N

axial piston
pump
variable
displacement

rotation
size
and
displacement

mounting
interface

variation

seals

thru drive
code

control

see next page

coupling
code

threads
code

Code

Displacement

Size

Code

Seals

Shaft seal

016
020
023
028

16 cm/rev
20 cm/rev
23 cm/rev
28 cm/rev

1
1
1
1

N
V
W
P
B

NBR
FKM
NBR
FKM
NBR

FKM
FKM
PTFE
PTFE
NBR

Code

Rotation 1)

R
L

Clockwise
Counter clockwise

1)

Code
1
H
Y
A
B
C

When looked on shaft

Code

Variation

1
2
9

Standard
Electronic displacement sensor 2)
Special adjustment 3)

2)
3)

as single part 7)

Single pump, no coupling


with coupling 25 x 1.5 x 15, DIN 5480
with coupling SAE A 9T-16/32 DP
with coupling SAE - 11T-16/32 DP
with coupling SAE B 13T-16/32 DP
with coupling SAE B-B 15T-16/32 DP

MK-PVBG1K01
MK-PVBG1K11
MK-PVBG1K12
MK-PVBG1K13
MK-PVBG1K14

not for horse power control


requires Kxxxx number
Code

Code
Mounting interface
Shaft
K
metr. ISO 4-hole flange 100 mm Cylindric, key
3019/2 4-hole flange 100 mm Splined, DIN 5480
L
D
SAE
4-hole flange SAE B
Cylindric, key
ISO
E
Splined, SAE
3019/1 4-hole flange SAE B-B

Code

Port4)

Threads5)

1
3
7
86)

BSPP
UNF
ISO 6149
ISO 6149

metric
UNC
UNC
metric

4)
5)
6)

Coupling for thru drive

T
Y
A
B
G
H
J

Thru drive option


No adaptor for 2nd pump
Single pump prepared for thru drive
with adaptor for 2nd pump
as single part 7)
SAE AA, 50.8 mm
MK-PVBG1Yxx
SAE A, 82.55 mm
MK-PVBG1Axx
SAE B, 101.6 mm
MK-PVBG1Bxx
metric, 63 mm
MK-PVBG1Gxx
metric, 80 mm
MK-PVBG1Hxx
metric, 100 mm
MK-PVBG1Jxx

See dimensions for details


7) to be ordered separately as single part
see page 61.

Drain, gage and flushing ports


All mounting and connecting threads
Mounting interface, code K and L only

Standard pump is not painted. Black painted pump and ATEX certification (Zone 2) is
available as special option. For additional informations please contact Parker Hannifin.

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 1


Code
0
1
M
M
M
M

0
0
M
R
F
T

Control options
1
0

No control
With cover plate, no control function (fixed displacement pump)
Standard pressure control, integrated pilot valve
Remote pressure control, integrated pilot valve
Load Sensing (flow) control, integrated pilot valve
Two spool LS control
Control variation

C
1
2
3
W
K
Z
B
P

Standard version 1)
NG6 interface top side for pilot valves
Remote pressure port int. supply , NG6 interface 2)
Remote pressure port ext. supply 2)
With unloading function, 24VDC solenoid 1)
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC*
Without integrated pilot valve, without NG6 interface 3)
MT1 with mounted pilot valve PVAC1P 2)

1) not for MT
2) only for MT
3) not for MT & MM

Horse power / Torque control


Displacem.
016
028

Code

B
C
D
E
G
H
K
L
C
C
1
W
K
Z
B

Code

Nominal HP
Nominal
at 1.500 rpm
torque
3 kW
20 Nm
4 kW
25 Nm
5.5 kW
35 Nm
7.5 kW
50 Nm
11 kW
71 Nm
15 kW
97 Nm
18.5 kW
120 Nm
Function
Horse power control with pressure control 4)
Horse power control with load sensing (single spool)
Control variation
Standard version
NG 6 interface top side
With unloading function, 24 VDC solenoid
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC* 4)
Without integrated pilot valve, without NG6 interface 4)

4) control variation Z and B


without pressure control

Control option

Electro hydraulic control


F
U

D
D

Proportional displacement control, no pressure compensation


Proportional displacement control, with pressure compensation

Control variation
R
K
M

pilot operated pressure control, open


NG6 interface
pilot operated pressure control, proportional
pilot valve type PVACRE..35 mounted
pilot operated pressure control, pressure sensor and proportional pilot
valve type PVACRE..35 mounted for pressure control and/or power
control

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 2

PV

R 1 K 1 T 1 N

axial piston
pump
variable
displacement

rotation
size
and
displacement

mounting
interface

variation

seals

thru drive
code

control

see next page

coupling
code

threads
code

Code

Displacement

Size

Code

Seals

Shaft seal

032
040
046

32 cm/rev
40 cm/rev
46 cm/rev

2
2
2

N
V
W
P
B

NBR
FKM
NBR
FKM
NBR

FKM
FKM
PTFE
PTFE
NBR

Code

Rotation 1)

Code

R
L

Clockwise
Counter clockwise

1
H
J
Y
A
B
C
D

1)

When looked on shaft

Code

Variation

1
2
9

Standard
Electronic displacement sensor 2)
Special adjustment 3)

Coupling for thru drive

as single part 7)

Single pump, no coupling


with coupling 25 x 1.5 x 15, DIN 5480
with coupling 32 x 1.5 x 20, DIN 5480
with coupling SAE A 9T-16/32 DP
with coupling SAE - 11T-16/32 DP
with coupling SAE B 13T-16/32 DP
with coupling SAE B-B 15T-16/32 DP
with coupling SAE C 14T-12/24 DP

MK-PVBG2K01
MK-PVBG2K02
MK-PVBG2K11
MK-PVBG2K12
MK-PVBG2K13
MK-PVBG2K14
MK-PVBG2K15

2)

3)

not for horse power control


requires Kxxxx number
Code

Code
Mounting interface
Shaft
K
metr. ISO 4-hole flange 125 mm Cylindric, key
3019/2 4-hole flange 125 mm Splined, DIN 5480
L
D
SAE
4-hole flange SAE C
Cylindric, key
ISO
E
4-hole flange SAE C
Splined, SAE
3019/1

Code

Port4)

Threads5)

1
3
7
86)

BSPP
UNF
ISO 6149
ISO 6149

metric
UNC
UNC
metric

T
A
B
C
G
H
J
K

Thru drive option


No adaptor for 2nd pump
Single pump prepared for thru drive
with adaptor for 2nd pump
as single part 6)
SAE A, 82.55 mm
MK-PVBG2Axx
SAE B, 101.6 mm
MK-PVBG2Bxx
SAE C, 127 mm
MK-PVBG2Cxx
metric, 63 mm
MK-PVBG2Gxx
metric, 80 mm
MK-PVBG2Hxx
metric, 100 mm
MK-PVBG2Jxx
metric, 125 mm
MK-PVBG2Kxx

See dimensions for details


7) to be ordered separately as single part
see page 61.

4)

Drain, gage and flushing ports


All mounting and connecting threads
6) Mounting interface, code K and L only
5)

Standard pump is not painted. Black painted pump and ATEX certification (Zone 2) is
available as special option. For additional informations please contact Parker Hannifin.

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 2


Code
0
1
M
M
M
M

0
0
M
R
F
T

Control options
1
0

No control
With cover plate, no control function (fixed displacement pump)
Standard pressure control, integrated pilot valve
Remote pressure control, integrated pilot valve
Load Sensing (flow) control, integrated pilot valve
Two spool LS control
Control variation

C
1
2
3
W
K
Z
B
P

Standard version 1)
NG6 interface top side for pilot valves
Remote pressure port int. supply , NG6 interface 2)
Remote pressure port ext. supply 2)
With unloading function, 24VDC solenoid 1)
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC*
Without integrated pilot valve, without NG6 interface 3)
MT1 with mounted pilot valve PVAC1P 2)

1) not for MT
2) only for MT
3) not for MT & MM

Horse power / Torque control


Displacem.
032
046

Code

D
E
G
H
K
M
S
L
C
C
1
W
K
Z
B

Code

Nominal HP
Nominal
at 1.500 rpm
torque
5.5 kW
35 Nm
7.5 kW
50 Nm
11 kW
71 Nm
15 kW
97 Nm
18.5 kW
120 Nm
22 kW
142 Nm
30 kW
195 Nm
Function
Horse power control with pressure control 4)
Horse power control with load sensing (single spool)
Control variation
Standard version
NG 6 interface top side
With unloading function, 24 VDC solenoid
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC* 4)
Without integrated pilot valve, without NG6 interface 4)

4) control variation Z and B


without pressure control

Control option

Electro hydraulic control


F
U

D
D

Proportional displacement control, no pressure compensation


Proportional displacement control, with pressure compensation

Control variation
R
K
M

pilot operated pressure control, open


NG6 interface
pilot operated pressure control, proportional
pilot valve type PVACRE..35 mounted
pilot operated pressure control, pressure sensor and proportional pilot
valve type PVACRE..35 mounted for pressure control and/or power
control

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 3

PV

R 1 K 1 T 1 N

axial piston
pump
variable
displacement
high
pressure
version

rotation
size
and
displacement

mounting
interface

variation

seals

thru drive
code

compensator

see next page

coupling
code

threads
code

Code

Displacement

Size

Code

Seals

Shaft seal

063
080
092

63 cm/rev
80 cm/rev
92 cm/rev

3
3
3

N
V
W
P
B

NBR
FKM
NBR
FKM
NBR

FKM
FKM
PTFE
PTFE
NBR

Code

Code

Rotation 1)

R
L

Clockwise
Counter clockwise

1)

1
H
J
K
Y
A
B
C
D
E
F

When looked on shaft

Code

Variation

1
2
9

Standard
Electronic displacement sensor 2)
Special adjustment 3)

2)

3)

not for horse power control


requires Kxxxx number

Code
Mounting interface
Shaft
K
metr. ISO 4-hole flange 160 mm Cylindric, key
3019/2 4-hole flange 160 mm Splined, DIN 5480
L
D
SAE
4-hole flange SAE D
Cylindric, key
ISO
E
4-hole flange SAE D
Splined, SAE
3019/1

Code

Port4)

Threads5)

1
3
4 6)
7
8

BSPP
UNF
BSPP
ISO 6149
ISO 6149

metric
UNC
metr. M14
UNC
metric

Coupling for thru drive

as single part 7)

Single pump, no coupling


with coupling 25 x 1.5 x 15, DIN 5480
with coupling 32 x 1.5 x 20, DIN 5480
with coupling 40 x 1.5 x 25, DIN 5480
with coupling SAE A 9T-16/32 DP
with coupling SAE - 11T-16/32 DP
with coupling SAE B 13T-16/32 DP
with coupling SAE B-B 15T-16/32 DP
with coupling SAE C 14T-12/24 DP
with coupling SAE C-C 17T-12/24 DP
with coupling SAE D, E 13T-8/16 DP

MK-PVBG3K01
MK-PVBG3K02
MK-PVBG3K03
MK-PVBG3K11
MK-PVBG3K12
MK-PVBG3K13
MK-PVBG3K14
MK-PVBG3K15
MK-PVBG3K16
MK-PVBG3K17

Code
T
A
B
C
D
G
H
J
K
L

4)

Thru drive option


No adaptor for 2nd pump
Single pump prepared for thru drive
with adaptor for 2nd pump
as single part 7)
SAE A, 82.55 mm
MK-PVBG3Axx
SAE B, 101.6 mm
MK-PVBG3Bxx
SAE C, 127 mm
MK-PVBG3Cxx
SAE D, 152.4 mm
MK-PVBG3Dxx
metric, 63 mm
MK-PVBG3Gxx
metric, 80 mm
MK-PVBG3Hxx
metric, 100 mm
MK-PVBG3Jxx
metric, 125 mm
MK-PVBG3Kxx
metric, 160 mm
MK-PVBG3Lxx

See dimensions for details


7) to be ordered separately as single part
see page 61.

Drain, gage and flushing ports


All mounting and connecting threads
6) For PV063-PV092 only: pressure port 1 1/4"
with 4 x M14 instead of 4 x M12
5)

Standard pump is not painted. Black painted pump and ATEX certification (Zone 2) is
available as special option. For additional informations please contact Parker Hannifin.

10

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 3


Code
0
1
M
M
M
M

0
0
M
R
F
T

Control options
1
0

No control
With cover plate, no control function (fixed displacement pump)
Standard pressure control, integrated pilot valve
Remote pressure control, integrated pilot valve
Load Sensing (flow) control, integrated pilot valve
Two spool LS control
Control variation

C
1
2
3
W
K
Z
B
P

Standard version 1)
NG6 interface top side for pilot valves
Remote pressure port int. supply , NG6 interface 2)
Remote pressure port ext. supply 2)
With unloading function, 24VDC solenoid 1)
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC*
Without integrated pilot valve, without NG6 interface 3)
MT1 with mounted pilot valve PVAC1P 2)

1) not for MT
2) only for MT
3) not for MT & MM

Horse power / Torque control


Displacem.
063
092

Code

G
H
K
M
S
T
U
W
L
C
C
1
W
K
Z
B

Code

Nominal HP
Nominal
at 1.500 rpm
torque
11 kW
71 Nm
15 kW
97 Nm
18.5 kW
120 Nm
22 kW
142 Nm
30 kW
195 Nm
37 kW
240 Nm
45 kW
290 Nm
55 kW
355 Nm
Function
Horse power control with pressure control 4)
Horse power control with load sensing (single spool)
Control variation
Standard version
NG 6 interface top side
With unloading function, 24 VDC solenoid
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC* 4)
Without integrated pilot valve, without NG6 interface 4)

4) control variation Z and B


without pressure control

Control option

Electro hydraulic control


F
U

D
D

Proportional displacement control, no pressure compensation


Proportional displacement control, with pressure compensation

Control variation
R
K
M

pilot operated pressure control, open


NG6 interface
pilot operated pressure control, proportional
pilot valve type PVACRE..35 mounted
pilot operated pressure control, pressure sensor and proportional pilot
valve type PVACRE..35 mounted for pressure control and/or power
control

11

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 4

PV

R 1 K 1 T 1 N

axial piston
pump
variable
displacement

rotation
size
and
displacement

Code

Displacement

Size

140
180

140 cm/rev
180 cm/rev

4
4

mounting
interface

variation

seals

thru drive
code

see next page

coupling
code

threads
code

Code
Code

Rotation 1)

R
L

Clockwise
Counter clockwise

1)

1
H
J
K
L
Y
A
B
C
D
E
F
G

When looked on shaft

Code

Variation

1
2
9

Standard
Electronic displacement sensor 2)
Special adjustment 3)

2)

3)

not for horse power control


requires Kxxxx number

Code
Mounting interface
Shaft
K
metr. ISO 4-hole flange 160 mm Cylindric, key
3019/2 4-hole flange 160 mm Splined, DIN 5480
L
D
4-hole flange SAE D
Cylindric, key
SAE
E
4-hole flange SAE D
Splined, SAE F
ISO
F
4-hole flange SAE D
Cylindric, key
3019/1
G
4-hole flange SAE D
Splined, SAE D

Code

Port4)

Threads5)

1
3
4 6)
7
8 7)

BSPP
UNF
BSPP
ISO 6149
ISO 6149

metric
UNC
metr. M14
UNC
metric

Code
T
A
B
C
D
H
J
K
L

Code

Seals

Shaft seal

N
V
W
P
B

NBR
FKM
NBR
FKM
NBR

FKM
FKM
PTFE
PTFE
NBR

Coupling for thru drive

as single part 8)

Single pump, no coupling


with coupling 25 x 1.5 x 15, DIN 5480
with coupling 32 x 1.5 x 20, DIN 5480
with coupling 40 x 1.5 x 25, DIN 5480
with coupling 50 x 2 x 24, DIN 5480
with coupling SAE A 9T-16/32 DP
with coupling SAE - 11T-16/32 DP
with coupling SAE B 13T-16/32 DP
with coupling SAE B-B 15T-16/32 DP
with coupling SAE C 14T-12/24 DP
with coupling SAE C-C 17T-12/24 DP
with coupling SAE D, E 13T-8/16 DP
with coupling SAE F 15T-8/16 DP

MK-PVBG4K01
MK-PVBG4K02
MK-PVBG4K03
MK-PVBG4K04
MK-PVBG4K11
MK-PVBG4K12
MK-PVBG4K13
MK-PVBG4K14
MK-PVBG4K15
MK-PVBG4K16
MK-PVBG4K17
MK-PVBG4K18

Thru drive option


No adaptor for 2nd pump
Single pump prepared for thru drive
with adaptor for 2nd pump
as single part 8)
SAE A, 82.55 mm
MK-PVBG4Axx
SAE B, 101.6 mm
MK-PVBG4Bxx
SAE C, 127 mm
MK-PVBG4Cxx
SAE D, 152.4 mm
MK-PVBG4Dxx
metric, 80 mm
MK-PVBG4Hxx
metric, 100 mm
MK-PVBG4Jxx
metric, 125 mm
MK-PVBG4Kxx
metric, 160 mm
MK-PVBG4Lxx

See dimensions for details


8) to be ordered separately as single part
see page 61.

4) Drain,

gage and flushing ports


5) All mounting and connecting threads
6) Pressure port 1 1/4" with 4 x M14 instead of 4 x M12
7) Mounting

control

interface, code K and L only

Standard pump is not painted. Black painted pump and ATEX certification (Zone 2) is
available as special option. For additional informations please contact Parker Hannifin.

12

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 4


Code
0
1
M
M
M
M

0
0
M
R
F
T

Control options
1
0

No control
With cover plate, no control function (fixed displacement pump)
Standard pressure control, integrated pilot valve
Remote pressure control, integrated pilot valve
Load Sensing (flow) control, integrated pilot valve
Two spool LS control
Control variation

C
1
2
3
W
K
Z
B
P

Standard version 1)
NG6 interface top side for pilot valves
Remote pressure port int. supply , NG6 interface 2)
Remote pressure port ext. supply 2)
With unloading function, 24VDC solenoid 1)
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC*
Without integrated pilot valve, without NG6 interface 3)
MT1 with mounted pilot valve PVAC1P 2)

1) not for MT
2) only for MT
3) not for MT & MM

Horse power / Torque control


Displacem.
140
180

Code

K
M
S
T
U
W
Y
Z
2
L
C
C
1
W
K
Z
B

Code

Nominal HP
Nominal
at 1.500 rpm
torque
18.5 kW
120 Nm
22 kW
142 Nm
30 kW
195 Nm
37 kW
240 Nm
45 kW
290 Nm
55 kW
355 Nm
75 kW
485 Nm
90 kW
585 Nm
110 kW
715 Nm
Function
Horse power control with pressure control 4)
Horse power control with load sensing (single spool)
Control variation
Standard version
NG 6 interface top side
With unloading function, 24 VDC solenoid
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC* 4)
Without integrated pilot valve, without NG6 interface 4)

4) control variation Z and B


without pressure control

Control option

Electro hydraulic control


F
U

D
D

Proportional displacement control, no pressure compensation


Proportional displacement control, with pressure compensation

Control variation
R
K
M

pilot operated pressure control, open


NG6 interface
pilot operated pressure control, proportional
pilot valve type PVACRE..35 mounted
pilot operated pressure control, pressure sensor and proportional pilot
valve type PVACRE..35 mounted for pressure control and/or power
control

13

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 5

PV

R 1 K 1 T 1 N

axial piston
pump
variable
displacement
high
pressure
version

rotation
size
and
displacement

Code

Displacement

Size

270

270 cm/rev

mounting
interface

variation

seals

thru drive
code

see next page

coupling
code

threads
code

Code

Rotation 1)

Code

R
L

Clockwise
Counter clockwise

1
H
J
K
L
M
Y
A
B
C
D
E
F
G

1)

When looked on shaft

Code

Variation

1
2
9

Standard
Electronic displacement sensor 2)
Special adjustment 3)

2)

3)

not for horse power control


requires Kxxxx number

Code
Mounting interface
Shaft
K
metr. ISO 4-hole flange 200 mm Cylindric, key
3019/2 4-hole flange 200 mm Splined, DIN 5480
L
D
SAE
4-hole flange SAE E
Cylindric, key
ISO
E
4-hole flange SAE E
Splined, SAE
3019/1

Code

Port4)

Threads5)

1
3
7
8

BSPP
UNF
ISO 6149
ISO 6149

metric
UNC
UNC
metric

4)
5)

compensator

Seals

Shaft seal

N
V
W
P
B

NBR
FKM
NBR
FKM
NBR

FKM
FKM
PTFE
PTFE
NBR

Coupling for thru drive

as single part 6)

Single pump, no coupling


with coupling 25 x 1.5 x 15, DIN 5480
with coupling 32 x 1.5 x 20, DIN 5480
with coupling 40 x 1.5 x 25, DIN 5480
with coupling 50 x 2 x 24, DIN 5480
with coupling 60 x 2 x 28, DIN 5480
with coupling SAE A 9T-16/32 DP
with coupling SAE - 11T-16/32 DP
with coupling SAE B 13T-16/32 DP
with coupling SAE B-B 15T-16/32 DP
with coupling SAE C 14T-12/24 DP
with coupling SAE C-C 17T-12/24 DP
with coupling SAE D, E 13T-8/16 DP
with coupling SAE F 15T-8/16 DP

MK-PVBG5K01
MK-PVBG5K02
MK-PVBG5K03
MK-PVBG5K04
MK-PVBG5K05
MK-PVBG5K11
MK-PVBG5K12
MK-PVBG5K13
MK-PVBG5K14
MK-PVBG5K15
MK-PVBG5K16
MK-PVBG5K17
MK-PVBG5K18

Code
T
A
B
C
D
E
H
J
K
L
M

Drain, gage and flushing ports


All mounting and connecting threads

Code

Thru drive option


No adaptor for 2nd pump
Single pump prepared for thru drive
with adaptor for 2nd pump
as single part 6)
SAE A, 82.55 mm
MK-PVBG5Axx
SAE B, 101.6 mm
MK-PVBG5Bxx
SAE C, 127 mm
MK-PVBG5Cxx
SAE D, 152.4 mm
MK-PVBG5Dxx
SAE E, 165.1 mm
MK-PVBG5Exx
metric, 80 mm
MK-PVBG5Hxx
metric, 100 mm
MK-PVBG5Jxx
metric, 125 mm
MK-PVBG5Kxx
metric, 160 mm
MK-PVBG5Lxx
metric, 200 mm
MK-PVBG5Mxx

See dimensions for details


6) to be ordered separately as single part
see page 61.

Standard pump is not painted. Black painted pump and ATEX certification (Zone 2) is
available as special option. For additional informations please contact Parker Hannifin.

14

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 5


Code
0
1
M
M
M
M

0
0
M
R
F
T

Control options
1
0

No control
With cover plate, no control function (fixed displacement pump)
Standard pressure control, integrated pilot valve
Remote pressure control, integrated pilot valve
Load Sensing (flow) control, integrated pilot valve
Two spool LS control
Control variation

C
1
2
3
W
K
Z
B
P

Standard version 1)
NG6 interface top side for pilot valves
Remote pressure port int. supply , NG6 interface 2)
Remote pressure port ext. supply 2)
With unloading function, 24VDC solenoid 1)
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC*
Without integrated pilot valve, without NG6 interface 3)
MT1 with mounted pilot valve PVAC1P 2)

1) not for MT
2) only for MT
3) not for MT & MM

Horse power / Torque control


Displacem.
270

Code

T
U
W
Y
Z
2
3
L
C
C
1
W
K
Z
B

Code

Nominal HP
Nominal
at 1.500 rpm
torque
37 kW
240 Nm
45 kW
290 Nm
55 kW
350 Nm
75 kW
480 Nm
90 kW
580 Nm
110 kW
700 Nm
132 kW
840 Nm
Function
Horse power control with pressure control 4)
Horse power control with load sensing (single spool)
Control variation
Standard version
NG 6 interface top side
With unloading function, 24 VDC solenoid
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC* 4)
Without integrated pilot valve, without NG6 interface 4)

4) control variation Z and B


without pressure control

Control option

Electro hydraulic control


F
U

D
D

Proportional displacement control, no pressure compensation


Proportional displacement control, with pressure compensation

Control variation
R
K
M

pilot operated pressure control, open


NG6 interface
pilot operated pressure control, proportional
pilot valve type PVACRE..35 mounted
pilot operated pressure control, pressure sensor and proportional pilot
valve type PVACRE..35 mounted for pressure control and/or power
control

15

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 6

PV

R 1 K 1 T 1 N

axial piston
pump
variable
displacement

rotation
size
and
displacement

mounting
interface

variation

seals

thru drive
code

control

see next page

coupling
code

threads
code

Code

Displacement

Size

Code

Seals

Shaft seal

360

360 cm/rev

N
V

NBR
FKM

FKM
FKM

Code
Code

Rotation 1)

Clockwise

1)

1
H
J
K
L
M
P
Y
A
B
C
D
E
F
G

When looked on shaft

Code

Variation

1
2
9

Standard
Electronic displacement sensor 2)
Special adjustment 3)

2)

3)

not for horse power control


requires Kxxxx number

Code
Mounting interface
4-hole flange 250 mm
K
L
metr. ISO 4-hole flange 250 mm
3019/2 4-hole flange 224 mm
R
T
4-hole flange 224 mm
D
SAE
4-hole flange SAE E
ISO
E
4-hole flange SAE E
3019/1

Code

Port4)

Threads5)

1
3

BSPP
UNF

metric
UNC

4)
5)

Shaft
Cylindric, key
Splined, DIN 5480
Cylindric, key
Splined, DIN 5480
Cylindric, key

Code
T

Splined, DIN 5480

A
B
C
D
E
H
J
K
L
M

Drain, gage and flushing ports


All mounting and connecting threads

Coupling for thru drive

as single part 6)

Single pump, no coupling


with coupling 25 x 1.5 x 15, DIN 5480
with coupling 32 x 1.5 x 20, DIN 5480
with coupling 40 x 1.5 x 25, DIN 5480
with coupling 50 x 2 x 24, DIN 5480
with coupling 60 x 2 x 28, DIN 5480
with coupling 70 x 3 x 22, DIN 5480
with coupling SAE A 9T-16/32 DP
with coupling SAE - 11T-16/32 DP
with coupling SAE B 13T-16/32 DP
with coupling SAE B-B 15T-16/32 DP
with coupling SAE C 14T-12/24 DP
with coupling SAE C-C 17T-12/24 DP
with coupling SAE D, E 13T-8/16 DP
with coupling SAE F 15T-8/16 DP

MK-PVBG5K01
MK-PVBG5K02
MK-PVBG5K03
MK-PVBG5K04
MK-PVBG5K05
MK-PVBG5K06
MK-PVBG5K11
MK-PVBG5K12
MK-PVBG5K13
MK-PVBG5K14
MK-PVBG5K15
MK-PVBG5K16
MK-PVBG5K17
MK-PVBG5K18

Thru drive option


No adaptor for 2nd pump
Single pump prepared for thru drive
with adaptor for 2nd pump
as single part 6)
SAE A, 82.55 mm
MK-PVBG5Axx
SAE B, 101.6 mm
MK-PVBG5Bxx
SAE C, 127 mm
MK-PVBG5Cxx
SAE D, 152.4 mm
MK-PVBG5Dxx
SAE E, 165.1 mm
MK-PVBG5Exx
metric, 80 mm
MK-PVBG5Hxx
metric, 100 mm
MK-PVBG5Jxx
metric, 125 mm
MK-PVBG5Kxx
metric, 160 mm
MK-PVBG5Lxx
metric, 200 mm
MK-PVBG5Mxx

See dimensions for details


6) to be ordered separately as single part
see page 61.
Standard pump is not painted. Black painted pump and ATEX certification (Zone 2) is
available as special option. For additional informations please contact Parker Hannifin.

16

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Ordering Code Frame Size 6


Code
0
1
M
M
M
M

0
0
M
R
F
T

Control options
1
0

No control
With cover plate, no control function (fixed displacement pump)
Standard pressure control, integrated pilot valve
Remote pressure control, integrated pilot valve
Load Sensing (flow) control, integrated pilot valve
Two spool LS control
Control variation

C
1
2
3
W
K
Z
B
P

Standard version 1)
NG6 interface top side for pilot valves
Remote pressure port int. supply , NG6 interface 2)
Remote pressure port ext. supply 2)
With unloading function, 24VDC solenoid 1)
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC*
Without integrated pilot valve, without NG6 interface 3)
MT1 with mounted pilot valve PVAC1P 2)

1) not for MT
2) only for MT
3) not for MT & MM

Horse power / Torque control


Displacem.
360

Code

U
W
Y
Z
2
3
4
5
6
L
C
C
1
W
K
Z
B
Code

Nominal HP
Nominal
at 1.500 rpm
torque
45 kW
290 Nm
55 kW
350 Nm
75 kW
480 Nm
90 kW
580 Nm
110 kW
700 Nm
132 kW
840 Nm
160 kW
1020 Nm
180 kW
1150 Nm
200 kW
1280 Nm
Function
Horse power control with pressure control 4)
Horse power control with load sensing (single spool)
Control variation
Standard version
NG 6 interface top side
With unloading function, 24 VDC solenoid
Prop.-pilot valve type PVACRE..35 mounted
Without integrated pilot valve, NG6 interface,
for mounting of accessory code PVAC* 4)
Without integrated pilot valve, without NG6 interface 4)

4) control variation Z and B


without pressure control

Control option

Electro hydraulic control


F
U

D
D

Proportional displacement control, no pressure compensation


Proportional displacement control, with pressure compensation

Control variation
R
K
M

pilot operated pressure control, open


NG6 interface
pilot operated pressure control, proportional
pilot valve type PVACRE..35 mounted
pilot operated pressure control, pressure sensor and proportional pilot
valve type PVACRE..35 mounted for pressure control and/or power
control

17

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Pressure Controls

Standard Pressure Control


Control option MMC
The standard pressure control adjusts the pump displacement according to
the actual need of flow in the system in order to keep the pressure constant.
Control schematics

BV
P

Response times of the pump are collected from a


circuit as below by measuring the pumps swash angle
movement at different pressures.

Dynamic characteristic of flow control *


Displacement [%]

MP1

BD

On/Off valve

100
75
50
25
0

PV360

Time on-stroke [ms]


against
against
50 bar
350 bar
520
180

Pressure adjustment range


Factory setting pressure
Differential pressure adjustment range
Factory setting differential pressure
Control oil consumption

t on stroke

* Curve shown exaggerated

Time de-stroke [ms]


zero stroke
zero stroke
50 bar
350 bar
120
82

t
de-stroke
Response time

15 to 350 bar 1)
50 bar
10 to 40 bar
15 bar
Max 8.0 l/min

1) For 420 bar please use MMZ control option (see next page)

18

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Catalogue HY30-3245/UK

Pressure Controls

Axial Piston Pumps


Series PVplus

Standard Pressure Control with NG6 Interface


Control option MM1
With code MM1 the standard pressure control has a
valve interface size NG 6 DIN 24340 (CETOP 03 acc.
RP35H, NFPA D03) on the top side.

BV
MP1

This interface allows the mounting of accessories like


multiple pressure selectors without the need of external
piping and valve mounting.

BD

Standard Pressure Control with Electrical Unloading


Control option MMW
With code MMW a solenoid operated directional control
valve (D1VW002KNJW) for electrical unloading is
mounted on the control top side.

BV

When the solenoid is de-energised, the pump compensates at a stand-by pressure of typically 15 bar. When
the solenoid is energised, the pump compensates at
the pressure adjusted on the integrated pilot valve.

MP1

BD

Standard Pressure Control with Proportional Pilot Valve


Control option MMK
With code MMK a proportional pilot valve of type
PVACRE..35 (see page 43) is mounted on the top side
interface.
BV

This allows a variation of the pump compensating pressure between 20 and 350 bar by an electrical signal.

MP1

BD

Standard Pressure Control without Integrated Pressure Pilot Valve


Control option MMZ
Control MMZ has no integrated pilot valve but a valve
interface NG6 DIN 24340 on the top.
BV

This version is recommended for valve accessories.

MP1

BD

For operation at >350 bar please select respective


valve accessories (see page 40)
S

19

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Remote Pressure Controls


Remote Pressure Control

Control option MRC


The remote pressure control adjusts the pump displacement according to the actual need of flow in the system in
order to keep the pressure constant at a level given by a remotely installed pilot valve.
Control schematics
PR

BV
P

Response times of the pump are collected from a


circuit as below by measuring the pumps swash angle
movement at different pressures.

Dynamic characteristic of flow control *


Displacement [%]

MP1

BD

On/Off valve

100
75
50
25
0

PV360

Time on-stroke [ms]


against
against
50 bar
350 bar
520
180

Pressure adjustment range


Factory setting pressure
Differential pressure adjustment range
Factory setting differential pressure
Control oil consumption

t on stroke

* Curve shown exaggerated

Time de-stroke [ms]


zero stroke
zero stroke
50 bar
350 bar
120
82

t
de-stroke
Response time

15 to 350 bar 1)
50 bar
10 to 40 bar
15 bar
Max 8.0 l/min

1) For 420 bar please use MRZ control option (see next page)

20

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Remote Pressure Controls

Remote Pressure Control with NG6 Interface


Control option MR1
With code MR1 the remote pressure control has a
valve interface size NG 6 DIN 24340 (CETOP 03 acc.
RP35H, NFPA D03) on the top side.

PR

BV
MP1

This interface allows the mounting of accessories like


multiple pressure selectors without the need of external
piping and valve mounting.

BD

Remote Pressure Control with Electrical Unloading

PR

Control option MRW


With code MRW a solenoid operated directional control
valve (D1VW002KNJW) for electrical unloading is
mounted on the control top side.

BV
MP1

When the solenoid is de-energised, the pump compensates at a stand-by pressure of typically 15 bar. When
the solenoid is energised, the pump compensates at
the pressure adjusted on the integrated pilot valve.
S

Remote Pressure Control with Proportional Pilot Valve

PR

Control option MRK


With code MRK a proportional pilot valve of type
PVACRE..35 (see page 43) is mounted on the top side
interface.

BV
MP1

This allows a variation of the pump compensating pressure between 20 and 350 bar by an electrical signal.

BD

BD

Remote Pressure Control without Integrated Pressure Pilot Valve


Control option MRZ
Control MRZ has no integrated pilot valve but a NG6
DIN 24240 interface topside.

Control option MRB


Control MRB has no integrated pilot valve.

PR

BV
MP1

PR

BD

BV
MP1

BD

This version is recommended for valve accessories.


21

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Load Sensing Controls


Load Sensing Control

Control option MFC


The pilot pressure of the load sensing control is taken from a load sensing port in the hydraulic system.
It is used to match pump flow to system demands.
Control schematics
PF
BV

BD
P

Response times of the pump are collected from a


circuit as below by measuring the pumps swash angle
movement at different pressures.

Dynamic characteristic of flow control *


Displacement [%]

MP1

Load valve

100
75
50
25
0

PV360

Time on-stroke [ms]


stand-by
stand-by
to 50 bar
to 350 bar
500
690

Pressure adjustment range


Factory setting pressure
Differential pressure adjustment range
Factory setting differential pressure
Control oil consumption

t on stroke

t
de-stroke
Response time

* Curve shown exaggerated

Time de-stroke [ms]


50 bar to
350 bar to
stand-by
stand-by
830
50
15 to 350 bar 1)
50 bar
10 to 40 bar
10 bar
Max 8.0 l/min

1) For 420 bar please use MFZ control option (see next page)

22

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Load Sensing Controls


Load Sensing Control with NG6 Interface

PF

Control option MF1


With code MF1 the remote pressure control has a
valve interface size NG 6 DIN 24340 (CETOP 03 acc.
RP35H, NFPA D03) on the top side.

BV

BD
MP1

This interface allows the mounting of accessories like


multiple pressure selectors without the need of external
piping and valve mounting.

Load Sensing Control with Electrical Unloading

PF

Control option MFW


With code MFW a solenoid operated directional control
valve (D1VW002KNJW) for electrical unloading is
mounted on the control top side.

BV

BD
MP1

When the solenoid is de-energised, the pump compensates at a stand-by pressure of typically 15 bar. When
the solenoid is energised, the pump compensates at
the pressure adjusted on the integrated pilot valve.
S

Load Sensing Control with Proportional Pilot Valve


PF

Control option MFK


With code MFK a proportional pilot valve of type
PVACRE..35 (see page 43) is mounted on the top side
interface.

BV

BD
MP1

This allows a variation of the pump compensating pressure between 20 and 350 bar by an electrical signal.

Load Sensing Control without Integrated Pressure Pilot Valve


Control option MFZ
Control MFZ has no integrated pilot valve but a NG6
DIN 24240 interface topside.

Control option MFB


Control MFB has no integrated pilot valve.
PF

PF
BV

BD
MP1

BD
MP1

This version is recommended for valve accessories.


23

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Load Sensing Controls


2 Spool Load Sensing Control

Control option MTP


The pilot pressure of the load sensing control is taken from a load sensing port in the hydraulic system. It is used
to match pump flow to system demands. With the 2 spool control the interaction of the two control functions is
avoided by using two separate control valves for flow and pressure compensation.
Control schematics
PF

BV

BD1
BD2

WV
MP1 P

Q
P

Response times of the pump are collected from a


circuit as below by measuring the pumps swash angle
movement at different pressures.

Dynamic characteristic of flow control *


Displacement [%]

Load valve

100
75
50
25
0

PV360

Time on-stroke [ms]


stand-by
stand-by
to 50 bar
to 350 bar
920
670

Pressure adjustment range


Factory setting pressure
Differential pressure adjustment range
Factory setting differential pressure
load sensing
Factory setting differential pressure,
pressure control
Control oil consumption

Time de-stroke [ms]


50 bar to
350 bar to
stand-by
stand-by
1000
170

t on stroke

* Curve shown exaggerated

t
de-stroke
Response time

15 to 350 bar 1)
50 bar
10 to 40 bar
10 bar
15 bar
Max 8.0 l/min

1) For 420 bar please use MTZ control option (see next page)

24

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Catalogue HY30-3245/UK

Load Sensing Controls

Axial Piston Pumps


Series PVplus

2 Spool Load Sensing Control with NG6 Interface without Integrated Pressure Pilot Valve
Control option MT1 & MTZ
Control MT1 & MTZ has no integrated pressure pilot
valve but NG 6 DIN 24340 interface topside.

PF

BV

BD1

This interface allows the mounting of accessories like


multiple pressure selectors without the need of external
piping and valve mounting.

BD2

WV
MP1 P

2 Spool Load Sensing Control with Proportional Pilot Valve


Control option MTK
With code MTK a proportional pilot valve of type
PVACRE..35 (see page 43) is mounted on the top side
interface.

PF

BV

BD1
BD2

WV

This allows a variation of the pump compensating pressure between 20 and 350 bar by an electrical signal.

MP1 P

2 Spool Load Sensing Control without Integrated Pressure Pilot Valve

Control option MT2


Control MT2 has a valve interface NG6 DIN 24340 on
the top side and remote pressure port internal supply.

PF

PR

BV

BD1
BD2

WV

MP1 P

2 Spool Load Sensing Control without Integrated Pressure Pilot Valve

Control option MT3


Control MT3 with pressure remote port external supply.

PF

PR

BD1
BD2

WV
MP1 P

25

P
T

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Horse Power/Torque Controls

Horse Power/Torque Controls with Pressure Control

Control option *LC


The horse power control type *L* provides the benefit of the pressure control, plus the ability to limit the input
power the pump will draw. These controls are beneficial when the power available from the prime mover for the
hydraulics is limited or the application power demand has both high flow/low pressure and low flow/high pressure
duty cycles.
Control schematics

BV
P

Response times of the pump are collected from a


circuit as below by measuring the pumps swash angle
movement at different pressures.

Dynamic characteristic of flow control *


Displacement [%]

MP1

BD

Load valve

100
75
50
25
0

PV360

Time on-stroke [ms]


against
against
50 bar
350 bar
90
90

Pressure adjustment range


Factory setting pressure
Differential pressure adjustment range
Factory setting differential pressure
Control oil consumption

t
de-stroke
Response time

* Curve shown exaggerated

Time de-stroke [ms]


zero stroke
zero stroke
50 bar
350 bar
100
100
15 to 350 bar
350 bar
10 to 40 bar
15 bar
Max 8.0 l/min

t on stroke

See Horse Power characteristic curves on page 30

26

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Horse Power/Torque Controls

Horse Power/Torque Control with NG6 Interface


Control option *L1
With code *L1 the horse power control has a valve
interface size NG 6 DIN 24340 (CETOP 03 acc.
RP35H, NFPA D03) on the top side.

BV

This interface allows the mounting of accessories like


multiple pressure selectors without the need of external
piping and valve mounting.

MP1

BD

Horse Power/Torque Control with Electrical Unloading


Control option *LW
With code *LW a solenoid operated directional control
valve (D1VW002KNJW) for electrical unloading is
mounted on the control top side.
MP1

When the solenoid is de-energised, the pump compensates at a stand-by pressure of typically 15 bar. When
the solenoid is energised, the pump compensates at
the pressure adjusted on the integrated pilot valve.

BD

BV
P

Horse Power/Torque Control with Proportional Pilot Valve


Control option *LK
With code *LK a proportional pilot valve of type
PVACRE..35 (see page 43) is mounted on the top side
interface.
MP1

This allows a variation of the pump compensating pressure between 20 and 350 bar by an electrical signal.

BD

BV
P

Horse Power/Torque Control without Integrated Pressure Pilot Valve


Control option *LZ
Control *LZ has no integrated pilot valve but a NG6 DIN
24240 interface topside.

Control option *LB


Control *LB has no integrated pilot valve.
PR

BV
MP1

BD

BD

BV
MP1

T
S

This version is recommended for valve accessories.


27

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Horse Power/Torque Controls

Horse Power/Torque Controls with Load Sensing


Control option *CC
The horse power control type *C* provides the benefit of the load sensing control, plus the ability to limit the input
power the pump will draw. These controls are beneficial when the power available from the prime mover for the
hydraulics is limited or the application power demand has both high flow/low pressure and low flow/high pressure
duty cycles.
Control schematics
PF
BV

BD
P

Response times of the pump are collected from a


circuit as below by measuring the pumps swash angle
movement at different pressures.

Dynamic characteristic of flow control *


Displacement [%]

MP1

Load valve

100
75
50
25
0

PV360

Time on-stroke [ms]


stand-by
stand-by
to 50 bar
to 350 bar
90
90

Pressure adjustment range


Factory setting pressure
Differential pressure adjustment range
Factory setting differential pressure
Control oil consumption

t
de-stroke
Response time

* Curve shown exaggerated

Time de-stroke [ms]


50 bar to
350 bar to
stand-by
stand-by
100
100
15 to 350 bar
350 bar
10 to 40 bar
15 bar
Max 8.0 l/min

t on stroke

See Horse Power characteristic curves on page 30

28

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Horse Power/Torque Controls

Horse Power/Torque Control with Load Sensing & NG6 Interface


Control option *C1
With code *C1 the horse power control has a valve
interface size NG 6 DIN 24340 (CETOP 03 acc.
RP35H, NFPA D03) on the top side.

PF
BV

BD
MP1

This interface allows the mounting of accessories like


multiple pressure selectors without the need of external
piping and valve mounting.

Horse Power/Torque Control with Load Sensing & Electrical Unloading


Control option *CW
With code *CW a solenoid operated directional control
valve (D1VW002KNJW) for electrical unloading is
mounted on the control top side.

PF
BV

BD
MP1

When the solenoid is de-energised, the pump compensates at a stand-by pressure of typically 15 bar. When
the solenoid is energised, the pump compensates at
the pressure adjusted on the integrated pilot valve.

Horse Power/Torque Control with Load Sensing & Proportional Valve


Control option *CK
With code *CK a proportional pilot valve of type
PVACRE..35 (see page 43) is mounted on the top side
interface.

PF
BV

BD
MP1

This allows a variation of the pump compensating pressure between 20 and 350 bar by an electrical signal.

Horse Power/Torque Control with Load Sensing without Integrated Pilot Valve
Control option *CZ
Control *CZ has no integrated pilot valve but NG6 DIN
24340 interface topside.

Control option *CB


Control *CB has no integrated pilot valve.
PF

PF

BV

BV

MP1

BD

BD
P

MP1

29

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Performance Curves

45

PV028
PV023
PV020
PV016

40
35

Flow rate Q [l/min]

Flow rate Q [l/min]

Typical Horse Power/Torque Control Characteristics


70

PV046
PV040
PV032

60

50
3
S=
0

30

kW

15

30

kW

kW

150

200

300

250

Pressure p [bar]

120

=5

100

Z=

160
140

90

kW

37

kW
M
kW
K= =22
18 k
,5 W
kW
30

80
60
40

kW

T=

S=

kW

100

20
0
0

PV140

180

120

kW

350

Pressure p [bar]

kW

45

300

250

210
200

45

kW
KK== M=2
1188 2
H= .,55 k kW
15 kW
W
G=
11 kW
kW

kW

200

37

150

75

T=

100

kW

U=

30

50

=5

S=

U=

kW

2k

kW

kW

80

350

PV092
PV080
PV063

40

kW

140

60

5.5

10

Flow rate Q [l/min]

100

D=

kW

7.5

Y=

Flow rate Q [l/min]

50

5.5

kW

kW

11

E=

3k

5
0

C=

B=

7.

E=

10

D=

G=

20

.5

kW

11

15

=2

18

15
H=

G=

K=

kW

H=

20

40

.5
18
K=

25

20
50

100

150

200

250

300

350

Pressure p [bar]

50

100

150

200

250

300

350

Pressure p [bar]

30

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Performance Curves

300

425

270
240

2=

Z=

210
180

U=

150

45

=5

S= T=3 kW
30 7 k
M
kW W
=2
2
kW

120
90
60

11

kW

kW

kW

350
300

50

100

150

75

150

250

300

350

Pressure p [bar]

90

kW

13

11
0

kW

kW
kW

W=
U= 55 k
T= 45 k W
37
W
kW

100

200

Z=

Y=

50
0

3=

2=

200

30
0

PV270

250

kW

90

Flow rate Q [l/min]

PV180

75
Y=

Flow rate Q [l/min]

Typical Horse Power/Torque Control Characteristics

50

100

150

200

250

300

350

Flow rate Q [l/min

Pressure p [bar]

550
PV360

500
450

6=
2
5= 00
4= 18 kW
0
16
0 k kW
3=
W
13
2k
2=
11
W
0k
Z=
W
90
kW
Y=
75
kW
W=
55
U=
45 kW
kW

400
350
300
250
200
150
100
50
0

50

100

150

200

250

300
350
Pressure p [bar]

Speed
: n = 1500 rev/min
Temperature
: t = 50 C
Fluid
: HLP, ISO VG46
Viscosity :
= 46 mm2/s at 40 C
Pressure
: Maximum 350 bar, depending on HP level

31

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Electronic P/Q Controls


Proportional Displacement Control

Control option FDV


The proportional displacement control allows the adjustment of the pump's output flow by an electrical input signal.
The actual displacement of the pump is monitored by an electronic displacement sensor and compared with the
commanded displacement in an electronic control module PQDXXA-Z10. The command is given as an electrical
input signal (0 - 10 V alternatively 4 - 20 mA) from the supervising machine control or a potentiometer.
Version FDV of the proportional control does not provide a pressure compensation. Therefore the hydraulic circuit
must be protected by a pressure relief valve.

Control schematics

MP1 P

P
P
U

A
A

T
T

UQ

= FDV included

Response times of the pump are collected from a


circuit as below by measuring the pumps swash angle
movement at different pressures.

Dynamic characteristic of flow control *


Displacement [%]

Load valve

100
75
50
25
0

PV360

Time on-stroke [ms]


stand-by
stand-by
to 50 bar
to 350 bar
255
154

Pressure adjustment range *


Factory setting pressure *
Differential pressure adjustment range *
Factory setting differential pressure *
Control oil consumption

t on stroke

* Curve shown exaggerated

Time de-stroke [ms]


50 bar to
350 bar to
stand-by
stand-by
266
183
25 to 350 bar
50 bar
10 to 40 bar
15 bar
Max 0.3 l/min

t
de-stroke
Response time

Internal pilot pressure required to control the pump


FDV
15 bar
UDR
25 bar
UDK
25 bar
UDM
25 bar

* Data valid for UD* version


32

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Catalogue HY30-3245/UK

Electronic P/Q Controls

Axial Piston Pumps


Series PVplus

Proportional Displacement Control with Overriding Pressure Control


Control option UDR
Control version UDR provides electro- hydraulic
displacement control and pressure stage mounted on
an elbow manifold.

BP
P

PP

T BD2

M
A

WV

The elbow manifold provides NG6/D03 interface on top


to mount a pressure pilot valve (not included in UDR).

MP1 P

Proportional Displacement Control with Proportional Pressure Control


Control option UDK
Control version UDK features proportional pressure
pilot valve PVACRE..35, which enables for electrohydraulic p/Q control.

BP
P

T BD2

PP

M
A

WV

By using the digital module PQDXXA-Z10 it is possible


to control the displacement proportionally with overriding open loop proportional pressure control.

MP1 P

Proportional Displacement Control with Closed Loop Pressure Control


P

Control option UDM


Control version UDM includes pressure transducer
Parker SCP 8181 CE. In combination with control
module PQDXXA-Z10 both closed loop pressure
control as well as electronic power limitation can be
realized.

BP

T BD2

M
P

WV
MP1

PP

UQ
UP

p
= UD* included

33

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Efficiency and Case Drain Flows

100

vol. efficiency

output flow

overall efficiency

16

80

12

15

60

10

ull

tf

ra
we
po

ut

inp

w
flo
40

20

dhead

er at dea
input pow
0

100

200

300
Pressure [bar]

Efficiency and case drain flows PV016, PV020, PV023


and PV028
The efficiency and power graphs are measured at an
input speed of n = 1500 rpm, a temperature of 50C and
a fluid viscosity of 30 mm2/s.
Case drain flow and compensator control flow leave via
the drain port of the pump. To the values shown are to
be added 1 to 1.2 l/min, if at pilot operated compensators the control flow of the pressure pilot valve also goes
through the pump.
Please note: The values shown below are only valid for
static operation. Under dynamic conditions and at rapid
compensation of the pump the volume displaced by the
servo piston also leaves the case drain port. This dynamic
control flow can reach up to 40 l/min! Therefore the case
drain line is to lead to the reservoir at full size and without
restrictions as short and direct as possible.
Case drain flow PV016-028 with pressure
compensator

overall efficiency
20

80

15

60

ull

er
ow

10

12

f
at

w
flo
40

p
ut

inp

100

200

full flow

300
Pressure [bar]

300

200

100

Pressure [bar]

40

20

100

20

10

10

at deadhead
200

300
Pressure [bar]

Efficiency [%] (overall, volymetric)

15

80

60

flo
w

u
np

at

output flow

20

30

100

vol. efficiency

40

ul
l

10

r
we
o
p

60

l fl
ul

40

25

fficienc
y

ow

15

50

ra
tf

overall efficiency
output flow
80

20

input power
0

overall
e

100

25 vol.
efficiency

i
8

dead head

34

0
0

in
pu
tp
ow
e

16

Efficiency [%] (overall, volymetric)

24

PV028
Input power [kW]

Output flow [l/min]

32

10

at deadhead

PV023
40

12

20

input power
0

14

Drain flow [l/min]

18

ficiency

Output flow [l/min]

24

100

25 outp
ut flow, vol. ef

Efficiency [%] (overall, volymetric)

30

Input power [kW]

Output flow [l/min]

PV020

Input power [kW]

20

20

Efficiency [%] (overall, volymetric)

25

Input power [kW]

Output flow [l/min]

Efficiency, power consumption


PV016

20

ad

at deadhe
input power
100

200

320
Pressure [bar]

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Efficiency and Case Drain Flows

30

output flow

overall efficiency

32

24

20

ow
ll fl

tf

ut

inp

ra
we
o
p

40

20

r at

input powe
0

0
0

80

60

16

10

100

100

deadhead
0
300 350
Pressure [bar]

200

Case drain flow PV032-046 with pressure


compensator

48

36

40

100

output flow, vol. effi

ciency
overall efficiency

32

24

60

ll fl

24

80

u
tf

ow

ra

e
ow

16

40

p
ut

inp
12

0
0

200

12
10

dead head

4
full flow

at deadhead

100

14

20

input power
0

Efficiency [%] (overall, volymetric)

60

Input power [kW]

Output flow [l/min]

PV040

Drain flow [l/min]

40

vol. efficiency

40

Efficiency and case drain flows PV032 to PV046


The efficiency and power graphs are measured at an
input speed of n = 1500 rpm, a temperature of 50 C and
a fluid viscosity of 30 mm2/s.
Case drain flow and compensator control flow leave via
the drain port of the pump. To the values shown are to
be added 1 to 1.2 l/min, if at pilot operated compensators the control flow of the pressure pilot valve also goes
through the pump.
Please note: The values shown below are only valid for
static operation. Under dynamic conditions and at rapid
compensation of the pump the volume displaced by the
servo piston also leaves the case drain port. This dynamic
control flow can reach up to 60 l/min! Therefore the case
drain line is to lead to the reservoir at full size and without
restrictions as short and direct as possible.

Efficiency [%] (overall, volymetric)

50

Input power [kW]

Output flow [l/min]

Efficiency, power consumption


PV032

300 350
Pressure [bar]

0
0

100

200

300

Pressure [bar]

64

48

32

50

overall efficiency

output flow

40

30

20

er
ow

at

80

ow

60

l fl

l
fu

40

tp

pu

in
16

100

vol. efficiency

10

0
0

Efficiency [%] (overall, volymetric)

80

Input power [kW]

Output flow [l/min]

PV046

20

input power
100

at deadhead
200

300 350
Pressure [bar]

35

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Efficiency and Case Drain Flows

overall efficiency

56

pu

in
20

14

60

ow

28

40

r
we
po

at

l fl
ul

40

Input power [kW]

Output flow [l/min]

96

100

200

80

300
Pressure [bar]

l. efficiency

overall efficiency
64

80

ow

ll fl

60

u
tf

32

48

pu

in

ra
we
o
p

40

16

24

100

output flow, vo

48

72

20

eadhead
wer at d
input po

PV080
120

80

Case drain flows PV063-092


Drain flow [l/min]

output flow

42

60

100

vol. efficiency

Efficiency [%] (overall, volymetric)

80

70

Efficiency and case drain flows PV063, PV080, PV092


The efficiency and power graphs are measured at an
input speed of n = 1500 rpm, a temperature of 50C and
a fluid viscosity of 30 mm2/s.
Case drain flow and compensator control flow leave via
the drain port of the pump. To the values shown are to
be added 1 to 1.2 l/min, if at pilot operated compensators the control flow of the pressure pilot valve also goes
through the pump.
Please note: The values shown below are only valid for
static operation. Under dynamic conditions and at rapid
compensation of the pump the volume displaced by the
servo piston also leaves the case drain port. This dynamic
control flow can reach up to 80 l/min! Therefore the case
drain line is to lead to the reservoir at full size and without
restrictions as short and direct as possible.

Efficiency [%] (overall, volymetric)

100

Input power [kW]

Output flow [l/min]

Efficiency, power consumption


PV063

12

8
dead head

20

eadhea
wer at d
input po
0

100

200

300
Pressure [bar]

150

120

90

Input power [kW]

Output flow [l/min]

PV092
100

overall efficiency

80

60

60

40

30

20

er
ow
p
t

at

ow

40

p
in

80

60

l fl

l
fu

full flow

0
0

100

200

300

Pressure [bar]

20

er
input pow
0

100

vol. efficiency

output flow

Efficiency [%] (overall, volymetric)

100

ad
at deadhe

200

300
Pressure [bar]

36

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Efficiency and Case Drain Flows

200

150

100

vol. efficiency

overall efficiency
120

output flow

80

ow

60

90

150

ll fl

60

100

pu

in

r
we
po

u
tf

40

30

50

Efficiency and case drain flows PV140, PV180


The efficiency and power graphs are measured at an
input speed of n = 1500 rpm, a temperature of 50C and
a fluid viscosity of 30 mm2/s.
Case drain flow and compensator control flow leave via
the drain port of the pump. To the values shown are to
be added 1 to 1.2 l/min, if at pilot operated compensators the control flow of the pressure pilot valve also goes
through the pump.
Please note: The values shown below are only valid for
static operation. Under dynamic conditions and at rapid
compensation of the pump the volume displaced by the
servo piston also leaves the case drain port. This dynamic
control flow can reach up to 120 l/min! Therefore the case
drain line is to lead to the reservoir at full size and without
restrictions as short and direct as possible.

Efficiency [%] (overall, volymetric)

250

Input power [kW]

Output flow [l/min]

Efficiency, power consumption


PV140

20

at deadhead
input power
100

200

180

120

60

output flow

140

105

l
ul

er
ow
p
t

f
at

w
flo

Case drain flows PV140-180

80

60

pu

70

100

vol. efficiency

fficienc
y

240

175

overall
e

300

Input power [kW]

Output flow [l/min]

PV180

300
Pressure [bar]

Drain flow [l/min]

Efficiency [%] (overall, volymetric)

18

12

dead head

40

in

35

20

ad

deadhe
input power at
0

100

200

300
Pressure [bar]

full flow

0
0

37

100

200

300

Pressure [bar]

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Efficiency and Case Drain Flows

ow

80

150

200

100

100

50

60

tp

ow
er

at

300

in

pu

40

Drain flow [l/min]

output flow

200

Efficiency [%] (overall, volymetric)

100

vol. efficiency
fficiency
overall e

l fl

400

250

Case drain flows PV270

fu
l

500

Input power [kW]

Output flow [l/min]

Efficiency, power consumption


PV270

24

16

dead head

20

input power at
0

100

full flow

0
0

deadhead

200

300
Pressure [bar]

100

200

300

Pressure [bar]

Efficiency and case drain flows PV270


The efficiency and power graphs are measured at an
input speed of n = 1500 rpm, a temperature of 50C and
a fluid viscosity of 30 mm2/s.
Case drain flow and compensator control flow leave via
the drain port of the pump. To the values shown are to
be added 1 to 1.2 l/min, if at pilot operated compensators the control flow of the pressure pilot valve also goes
through the pump.
Please note: The values shown below are only valid for
static operation. Under dynamic conditions and at rapid
compensation of the pump the volume displaced by the
servo piston also leaves the case drain port. This dynamic
control flow can reach up to 120 l/min! Therefore the case
drain line is to lead to the reservoir at full size and without
restrictions as short and direct as possible.

38

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Performance Curves

Typical drive power at full displacement


Input power full stroke

Typical inlet characteristics vs. speed at


various percentage displacements
Inlet characteristics

Displacement
95% 100%

400

Input power [kW]

Self priming speed [rpm]

1850
1800
1750
1700
1650

1750 rpm

300
250

1500 rpm

200
150

1600

100

1550

50

1500
0.8

0.9

1.0

Inlet pressure [bar]

100%

25

50

75 100 125 150 175 200 225 250 275 300 325 350

Pressure [bar]

Typical compensated power


Input power zero stroke
35

Input power [kW]

Volumetric

90%

1.1

Typical efficiency at full displacement and


1500 rpm
Efficiency [%]

350

Overall

30

1750 rpm
25
20

80%

1500 rpm
15
10

70%

60%

25 50 75 100 125 150 175 200 225 250 275 300 325 350

Pressure [bar]

50

75 100 125 150 175 200 225 250 275 300 325 350

Pressure [bar]

Case drain flows


Drain flow [l/min]

25

40

32

24

dead head
16

full flow
0

100

200

300

360

Pressure [bar]

The curves show typical characteristics measured under


following conditions:
Fluid: Mineral oil ISO VG 22 at 32 C
Inlet pressure 1,0 bar (absolute), measured at inlet port.
39

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Accessories Control

PV

AC

Accessories Function
For
for
PV pump
controls
series

Code
1P
1E
2P
2E

2M

Mounting
bolts

Code

Function
Max. pressure relief
1 pressure,
electrical unloading
stand by default
2 pressures,
electrical selection
2 pressures + stand by
electrical selection
low pressure default
2 pressures + stand by
electrical selection
stand by default

M
S

Code
C
S
M

Threads

Adjustment Solenoid Solenoid Nominal


acces- pressure
sories

Seals

Code

Threads

35
42

Metric
SAE / UNC

Code

Seals

N
V

NBR
FPM

Code

For single controls


Without bolts
For code UP*/MT*

Adjustment

Spindle with
lock nut
L
DIN lock 1)
1) only for 1P & 2P
S

Dimensions
PVAC1P*

350 bar
420 bar

Code

Solenoid accessories

omit

For function 1P
DIN plug socket
without plug

Mounting bolts

Nominal pressure

Code

Solenoid voltage

omit
Y
T
J

For function 1P
110V/50Hz - 120V/60Hz
220V/50Hz - 240V/60Hz
24V DC

PVAC1E*
48

DC solenoid 205
AC solenoid 190

133

Adjustment
Code S

165
Adjustment
Code L

PVAC2P*

PVAC2M*/PVAC2E*
48

48

DC solenoid 241
AC solenoid 211

High
pressure

133

133

DC solenoid 205
AC solenoid 190

High
pressure

Low
pressure

40

Low
pressure

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Catalogue HY30-3245/UK

Accessories Control

Axial Piston Pumps


Series PVplus

Schematics PVAC1P*

Schematics PVAC1E*

Schematics PVAC2P*

Schematics PVAC2M*/PVAC2E*

*2M*

41

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Accessories Control

Proportional pressure relief valve PVACRE*


Function
When the pressure in port P exeeds the pressure setting
at the solenoid, the poppet opens to port T and limits the
pressure in port P to the adjusted level.
The optimum performance can be achieved in combination with the digital amplifier module PCD00A-400 (see
catalogue HY11-3500 for reference).

Technical data
General
Nominal size
Mounting position
Ambient temperature
Weight
Hydraulic
Max. operating pressure
Pressure stages
Fluid
Viscosity, recommended
permitted
Fluid temperature
Filtration
Linearity
Repeatability
Hysteresis
Electrical
Duty ratio
Protection class
Nominal voltage
Coil resistance
Solenoid connection
Power amplifier, recommended

DIN NG06 / CETOP03 / NFPA D03


as desired, horizontal mounting preferred
[C] -20 ... +70
[kg] 1.8
[bar] Ports P and A up to 420; port T depressurized
[bar] 350, 420
Hydraulic oil as per DIN 51524 ... 525
[cSt]/ [mm/s] 30 ... 80
[cSt]/ [mm/s] 12 ... 380
[C] -20 ... +60
ISO 4406 (1999), 18/16/13
[%] 2.8
[%] <1
[%] 1.5 of pmax
[%] 100 ED
IP 65 in accordance with EN 60529 (plugged and mounted)
[V] 16 (1.3 A max. current)
[Ohm] 4 at 20C
Connector as per EN 175301-803
PCD00A-400

42

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Accessories Control
Ordering code proportional pressure relief valve

PV

AC

RE

Pump
series PV

Accessories
for controller

Prop.
pressure
valve

Mounting
bolts

Thread
option

Seal

Nominal
pressure

Code
35
42
Code

Mounting bolts/ ports

C
S

For single controller


Without bolts
For code UP*/MT*
design series 45/46

Code
M
S

Schematic PVACRE*

Thread option
Metric
SAE / UNC

Nominal pressure
350 bar
420 bar

Code

Seal

N
V

NBR
FPM

Dimensions PVACRE*

Example for PVACRE* mounted

P
MP1

1/16" NPT
(for P, T)

43

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV016 - 028, metric version


Drain port L1; G1/2"
optional M22x1.5; ISO 6149-1
(thread options 7 and 8)
or 7/8"-14 UNF
(thread option 3)

Interface for
horse power pilot cartridge
or LVDT for
displacement feedback
32

94
25k6

131

219

100h8

79
13

52
132
max. 130

197.5

max. 212

10
9.0
Gage port M; G1/4"
optional M12x1.5; ISO 6149-1
(thread options 7 and 8)
or 7/16"-20 UNF
(thread option 3)

90
55

key
8x7x40
DIN 6885

28 -0.25
48
15

125

thread M10,
22 deep

50

170.5

119
162.5

Drain port L2 and


L3 (opposite); G1/2"
optional M22x1.5; ISO 6149-1
(thread options 7 and 8)
or 7/8"-14 UNF
(thread option 3)

OUTLET for metric and


SAE version:
flage acc. ISO 6162
DN19; PN400

50.8

12

The pump shown above has


Mounting option K
and thru drive variation T
(prepared for thru drive)

4xM10, 18 deep
optional 3/8"-16UNC-2B
(thread options 3 and 7)
23.8
100h8
30.2

Mounting optional L
splined shaft W25x1.5x15x8f
DIN 5480

INLET for metric and


SAE version:
flage acc. ISO 6162
DN32; PN250
18

58.7
4xM10, 18 deep
optional 7/16"-14UNC-2B
(thread options 3 and 7)

43

Shown is a clockwise rotating pump with standard pressure compensator.


Counter clockwise rotating pumps have inlet, outlet and gage port reversed.

44

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV016 - 028, SAE version


9.4
25.4 -0.05

13.5

28.2 0.15

Key:
6.35 x 6.35
40 long

89.9

101.6 -0.05
Thread:
3/8"-16UNC-2B
22 deep

44.9

50
44.9

Shown above is
Mounting option D

89.9
101.6 -0.05

Mounting option E
Splined shaft 15T-16/32 DP,
flat root, side fit ANSI B92.1
20
46

Variation with thru drive

Thru drive:
splined shaft
13T-16/32 DP,
flat root, side fit

G
E

197.5
(224.5)

B
27
47

Thru drive adaptors are available with the following dimensions


Drawing Dimension

Thru drive option

Metr

UNC

Remark

Metr

UNC

50.8

82

M8

5/16"-18

SAE AA 2-Bolt

82.55

106

M10

3/8"-16

SAE A 2-Bolt

101.6

10.5

127

89.8

M12

1/2"-13

SAE B 4-Bolt

63

8.5

85

60.1

M8

5/16"-18

100

M8

5/16"-18

2/4-Bolt

80

8.5

103

72.8

M8

5/16"-18

109

M10

3/8"-16

2/4-Bolt

100

10,5

125

88.4

M10

3/8"-16

45

4-Bolt

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV032 - 046, metric version

Drain port L1; G3/4"


optional M27 x 2; ISO 6149-1
(thread options 7 and 8)
or 1 1/16"-12 UNF
(thread option 3)
255.5

Interface for power pilot


cartridge or LVDT for
displacement feedback

PVCMMCN Serie 45
Code AM 350bar

36.5
112.5
32 k6
125 h8

149
97
16

68
160
max 130

227
max 248

Gage port M; G1/4"


optional M12x1,5; ISO 6149-1
(thread options 7 and 8)
or 7/16" - 20 UNF
(thread option 3)

9
10

99

35-0.25 Key
10 x 8 x 56
DIN 6885

71
60
17

14
160

Thread M10,
22 deep

50

185

138

197

OUTLET for metric and


SAE version:
flange acc. ISO 6162
DN25; PN400

57.2

27.8

Drain ports L2 and L3


(opposite); G3/4"
optional M27 x 2: ISO 6149-1
(thread options 7 and 8)
or 1 1/16" - 12 UNF
(thread option 3)

The pump shown above has


Mounting option K
and thru drive variation T
(prepared for thru drive)

Mounting optional L
splined shaft W32x1,5x20x8f
DIN 5480

4 x M12, 18 deep
optional 7/16"-14 UNC-2B
(thread options 3 and 7)

125 h8

INLET for metric and


SAE version:
flange acc. ISO 6162
DN38; PN200

69.9

35.7

4 x M12, 18 deep
optional 1/2"-13 UNC-2B
(thread options 3 and 7)

23.5
47

Shown is a clockwise rotating pump with standard pressure compensator.


Counter clockwise rotating pumps have inlet, outlet and gage port reversed.

46

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV032 - 046, SAE version

31.75-0.05
32.50.13
127-0.05

14

Key:
7.94 x 7.94
56 long

114.5

Thread:
3/8"-16UNC-2B
22 deep

57.25

12.7

8
60
68

Shown above is
Mounting option D

57.25

127-0.05

114.5

12.7
Mounting option E
Splined shaft 14T-12/24 DP,
flat root, side fit ANSI B92.1
34
56

Variation with thru drive

Thru drive:
splined shaft
W25x1,5x15x8f
DIN 5480
E

227

D
K

At threads options 3 and 7 the dimensions E and G are UNC - 2B threads.

Thru drive adaptors are available with the following dimensions


Drawing Dimension

82.55

F
UNC

Thru drive option


A

E
Metr

3/8"-16

48

261

SAE A 2-Bolt

Metr

UNC

106

M10

Remark

101.6

11

127

89.8

M12

1/2"-13

146

M12

1/2"-13

48

261

SAE B 2/4-Bolt

127

13.5

162

114.6

M12

1/2"-13

63

276

SAE C 4-Bolt

63

8.5

85

60.1

M8

5/16"-18

100

M8

5/16"-18

48

261

2/4-Bolt

80

8.5

103

72.8

M8

5/16"-18

109

M10

3/8"-16

48

261

2/4-Bolt

100

10.5

125

88.4

M10

3/8"-16

140

M12

1/2"-13

48

261

2/4-Bolt

125

10.5

160

113.1

M12

1/2"-13

48

261

4-Bolt

47

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV 063 - 092 Metric

Drain ports L1, L2 and L3; G3/4"


optional M27 x 2; ISO 6149-1
(tread option 7 and 8)
or 1 1/16" - 12 UNF
(tread option 3)

120

40 k6

160 h8
196

132

178

Mounting interface for


horse power pilot or LVDT
for displacement feedback

20
43.5
287
Max. 308

9
92

Max. 133
200

Gage port M; G1/4", optional M12 x 1.5; ISO


6149-1 (tread option 7 and 8) or 7/16"- 20 UNF
(tread option 3)

18

Key 12 x 8 x 80
DIN 6885

20

26

43-0.25

86
78

121

9
10

64

Thread
M12 - 28 deep

187.5

The pump shown above has


Mounting option K
and thru drive variation T
(prepared for thru drive)

236
252

77.8
50

INLET for metric and SAE


version:
flange according ISO 6162
DN 51; PN 200 bar
4 x M12, 20 deep
optional 1/2" - 13 UNC - 2B
(thread options 3 and 7)

56
30

66.6
32

31.8

4 x M12, 20 deep
optional 1/2" - 13 UNC - 2B
(thread options 3 and 7)
or thread options 4:
4 x M14, 20 deep
OUTLET for metric and SAE version:
flange according ISO 6162
DN 32; PN 400 bar

48

160 h8

42.9

Mounting option L, splined shaft


W40 x 1.5 x 25 x 8f DIN 5480

Shown is a clockwise rotating pump with standard


pressure compensator.
Counter clockwise rotating pumps have inlet, outlet and
gage port reversed.
Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV 063 - 092 SAE Version

20.6

49.3-0.05

80.8

161.6

152.4

44.45-0.05

Key: 11.11x11.11
80 long

12.6
8

Thread
1/2"-13
UNC-2B
28 deep

82
90

Shown above is
Mounting option D

161.6

Mounting option E
splined shaft 13T-8/16 DP,
flat root, side fit ANSI B92.1

152.4-0.05

45

80.8

75

Variation with thru drive

Output: splined shaft


W32x1.5x20x8f DIN 5480

D
F

287
L
K

Thru drive adaptors are available with the following dimensions


Drawing Dimension

Thru drive option


A
B
C
D
G
H
J
K
L

82.55
101.6
127
152.4
63
80
100
125
160

8
11
13.5
13.5
8.5
8.5
10.5
10.5
13.5

127
162
228.5
85
103
125
160
200

89.8
114.6
161.6
60.1
72.8
88.4
113.1
141.4

Metr

UNC

M12
M12
M16
M8
M8
M10
M12
M16

1/2"-13
1/2"-13
5/8"-11
5/16"-18
5/16"-18
3/8"-16
1/2"-13
5/8"-11

49

106
146
181
100
109
140
180
-

G
Metr

UNC

M10
M12
M16
M8
M10
M12
M16
-

3/8"-16
1/2"-13
5/8"-11
5/16"-18
3/8"-16
1/2"-13
5/8"-11
-

58
58
58
83
58
58
58
58
58

326
326
326
351
326
326
326
326
326

Remark

SAE A 2-Bolt
SAE B 2/4-Bolt
SAE C 2/4-Bolt
SAE D 4-Bolt
2/4-Bolt
2/4-Bolt
2/4-Bolt
2/4-Bolt
4-Bolt

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV 140 - 180 Metric

Drain ports L2; G1"


optional M33 x 2; ISO 6149-1
(tread option 7 and 8)
or 1 5/16" - 12 UNF
(tread option 3)

182
158
202

20

145

97

35

160 h8

35

50 k6

Mounting interface for


horse power pilot or
LVDT for displacement
feedback

9.3

48

92

350

Max. 133

Max. 386

200

9.3
10

Thread
M16 - 36 deep

146

53.5-0.25

105

106

283

18

Gage port M; G1/4",


optional M12 x 1.5; ISO 6149-1
(tread option 7 and 8)
or 7/16- 20 UNF (tread option 3)

Key 14 x 9 x 75
DIN 6885
15.4
230

Bearing flushing port L4; G1/4",


optional M12 x 1.5; ISO 6149-1
(tread option 7 and 8)
or 7/16" - 20 UNF
(tread option 3)

63

88.9

Pressure port: 295


Suction port: 305

32

66.6

31.8

40

Drain ports L3,


dimensions see L2

The pump shown above has


Mounting option K
and thru drive variation T
(prepared for thru drive)

INLET for metric and SAE


version:
flange according ISO 6162
DN 64; PN 160 bar

160 h8

4 x M12, 20 deep
optional 1/2" - 13 UNC - 2B
(thread options 3 and 7)

50.8

00

Mounting option L,
splined shaft
W50x2x24 x 9g DIN 5480

4 x M12, 20 deep
optional 1/2" - 13 UNC - 2B
(thread options 3 and 7)
46
or thread options 4:
4 x M14, 22 deep
78
OUTLET for metric and SAE
version:
Shown is a clockwise rotating pump with standard pressure control.
flange according ISO 6162
Counter clockwise rotating pump have inlet, outlet and gage port reversed.
DN 32; PN 400 bar

50

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

56.4 0.13

Key: 12.7x12.7
75 long

21

161.6

80.8

152.4 -0.05

50.8 -0.05

PV 140 - 180 SAE Version

Thread
5/8"-11 UNC-2B
25 deep

12.3
8

91.4

80.8

99.4

Mounting option F

152.4 -0.05

52.5
88

Mounting option G
splined shaft 13T-8/16 DP,
flat root, side fit ANSI B92.1

Key: 11.11x11.11
55 long

49.3 0.13

152.4 -0.05

44.45 -0.05

Mounting option E
splined shaft 15T-8/16 DP,
flat root, side fit ANSI B92.1

161.6

40

Thread
1/2"-13 UNC-2B
25 deep

75

Variation with thru drive

152.4 -0.05

Shown above is
Mounting option D

75

Output: splined shaft


W40x1.5x25x8f DIN 5480

B
65

350

(415)

97

Thru drive adaptors are available with the following dimensions


Drawing Dimension

Thru drive option


A
B
C
D
H
J
K
L

82.55
101.6
127
152.4
80
100
125
160

8
11
13.5
13.5
8.5
10.5
10.5
13.5

127
162
228.5
103
125
160
200

89.8
114.6
161.6
72.8
88.4
113.1
141.4

Metr

UNC

M12
M12
M16
M8
M10
M12
M16

1/2"-13
1/2"-13
5/8"-11
5/16"-18
3/8"-16
1/2"-13
5/8"-11

51

106
146
181
109
140
180
-

Remark

Metr

UNC

M10
M12
M16
M10
M12
M16
-

3/8"-16
1/2"-13
5/8"-11
3/8"-16
1/2"-13
5/8"-11
-

SAE A 2-Bolt
SAE B 2/4-Bolt
SAE C 2/4-Bolt
SAE D 4-Bolt
2/4-Bolt
2/4-Bolt
2/4-Bolt
4-Bolt

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV 270 Metric

Drain ports L1; G1 1/4"


optional M42 x 2; ISO 6149-1
(tread option 7 and 8)
or 1 5/8" - 12 UNF
(tread option 3)

176

65 k6

200 h8

184

230

Mounting interface for


horse power pilot or LVDT
for displacement feedback

25

115

60

472.5
250

Max 510

265

128

Key 18 x 11 x 98
DIN 6885

22

10

110

173

Gage port M; G1/4",


optional M12 x 1.5; ISO 6149-1 (tread option 7 and 8)
or 7/16- 20 UNF (tread option 3)

Thread
M20 - 42 deep

135

100

250

Bearing flushing port L4; G1/4",


optional M12 x 1.5; ISO 6149-1
(tread option 7 and 8)
or 7/16" - 20 UNF
(tread option 3)

294
378

INLET for metric and SAE


version:
flange according ISO 6162
DN 89; PN 35 bar

88

120.7

403

80
46

4 x M16, 30 deep
optional 5/8" - 11 UNC - 2B
(thread options 3 and 7)
200

69.9

38

36.5

79.3

The pump shown above has


Mounting option K
and thru drive variation T
(prepared for thru drive)

Mounting option L, splined shaft


W60 x 2 x 28 x 9g DIN 5480

4 x M16, 30 deep
optional 5/8" - 11 UNC - 2B
(thread options 3 and 7)
OUTLET for metric and
SAE version:
flange according ISO 6162
DN 38; PN 400 bar

Shown is a clockwise rotating pump with standard pressure control.


Counter clockwise rotating pump have inlet, outlet and gage port
reversed.

52

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV 270 SAE Version

15.9
89.5

20.5

112.25

224.5

165.1 -0.05

50.8 -0.05
56.4 0.13

Key: 12.7x12.7
75 long

Thread
5/8"-11
UNC-2B
25 deep

112.25

97.5

51.5

165.1 -0.05

Shown above is
Mounting option D

224.5

Mounting option E
splined shaft 15T-8/16 DP,
flat root, side fit ANSI B92.1

88

Output: splined shaft


W50x2x24x9g DIN 5480

472.5
531.5

Variation with thru drive

D
F

98

Thru drive adaptors are available with the following dimensions


Drawing Dimension
Thru drive option
A
B
C
D
E
H
J
K
L
M

82.55
101.6
127
152.4
165.1
80
100
125
160
200

8
11
13.5
13.5
17
8.5
10.5
10.5
13.5
13.5

127
162
228.5
317.5
103
125
160
200
250

89.8
114.6
161.6
224.5
72.8
88.4
113.1
141.4
176.8

53

Metr

UNC

M12
M12
M16
M20
M8
M10
M12
M16
M20

1/2"-13
1/2"-13
5/8"-11
3/4"-10
5/16"-18
3/8"-16
1/2"-13
5/8"-11
3/4"-10

106
146
181
229
109
140
180
224
-

Remark

Metr

UNC

M10
M12
M16
M16
M10
M12
M16
M20
-

3/8"-16
1/2"-13
5/8"-11
5/8"-11
3/8"-16
1/2"-13
5/8"-11
3/4"-10
-

SAE A 2-Bolt
SAE B 2/4-Bolt
SAE C 2/4-Bolt
SAE D 2/4-Bolt
SAE E 4-Bolt
2/4-Bolt
2/4-Bolt
2/4-Bolt
2/4-Bolt
4-Bolt

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV 360 Metric

Drain ports L1, L2 and L3; G1 1/4"


optional 1 5/8" - 12 UNF
(thread option 3)

Mounting interface for


horse power pilot
or LVDT for
displacement feedback

L2
L1

L3

230
184

70m7
250h8
265

176

60
max 514.5

25

9
115

477

max. 133
250

Gage port M; G1/4", optional


7/16- 20 UNF (tread option 3)

9
10

173

Key 20 x 12 x 100
DIN 6885

26

74.5-0.25

128
117

Thread
M20 - 42 deep

315

100
Bearing flushing port L4; G1/4",
optional 7/16" - 20 UNF
(thread option 3)

377

The pump shown above has Mounting option K


and thru drive variation T
(prepared for thru drive)

294

408

OUTLET for metric and


SAE version:

flange according ISO 6162


DN 38; PN 400 bar
1 1/2"
38
4 x M16, 30 deep
optional 5/8" - 11 UNC - 2B
(thread option 3)

79.3

24
46

36.5
77.8

130.2

Thread
M20 - 42 deep

INLET for metric and


SAE version:

280
224h8

80
90

flange according ISO 6162


DN 102; PN 35 bar
4"
102
4 x M16, 30 deep
optional 5/8" - 11 UNC - 2B
(thread option 3)

250h8 (L)
resp.
224h8 (T)

Mounting option L, T, splined shaft


W 70 x 3 x 22 x 8f DIN 5480
mounting option R
pilot diameter 224 mm

Shown is a clockwise rotating pump with standard pressure control.


Counter clockwise rotating pump have inlet, outlet and gage port reversed.

54

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Dimensions

PV 360 SAE Version

78-0.25
69.85-0.05

21
Key:
19.05x19.05
88.9 long

112.25

165.1-0.05
Thread
5/8"-11
UNC-2B
36 deep

224.5

92
100
112.25

Shown above is
Mounting option D

224.5
Note:
The dimensions shown conform to ISO 3019/1
the actual hole dimensions conform to ISO 3019/2
(pitch 315, hole 26, see previous page)
and cover ISO 3019/1 dimensions as well.
Use washers when assembling pump.

10
15.6

165.1-0.05
Mounting option E
splined shaft W 70x3x22x8f,
DIN 5480

46
90

Variation with thru drive

Output: splined shaft


W 50x2x24x9g DIN 5480

B
477

59

101

(536)

Thru drive adaptors are available with the following dimensions


Drawing Dimension
Thru drive option
A
B
C
D
E
H
J
K
L
M

82.55
101.6
127
152.4
165.1
80
100
125
160
200

8
11
13.5
13.5
17
8.5
10.5
10.5
13.5
13.5

127
162
228.5
317.5
103
125
160
200
250

89.8
114.6
161.6
224.5
72.8
88.4
113.1
141.4
176.8

55

Metr

UNC

M12
M12
M16
M20
M8
M10
M12
M16
M20

1/2"-13
1/2"-13
5/8"-11
3/4"-10
5/16"-18
3/8"-16
1/2"-13
5/8"-11
3/4"-10

106
146
181
229
109
140
180
224
-

Remark

Metr

UNC

M10
M12
M16
M16
M10
M12
M16
M20
-

3/8"-16
1/2"-13
5/8"-11
5/8"-11
3/8"-16
1/2"-13
5/8"-11
3/4"-10
-

SAE A 2-Bolt
SAE B 2/4-Bolt
SAE C 2/4-Bolt
SAE D 2/4-Bolt
SAE E 4-Bolt
2/4-Bolt
2/4-Bolt
2/4-Bolt
2/4-Bolt
4-Bolt

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Control Dimensions
Dimensions standard pressure control, code ...MMC

46
41

max. 172

43.4

45

54

24

Pump axis

88.5

Controls with code ...MM1 have a NG6 / Cetop 3 interface topside (as shown below)
Dimensions remote pressure and load sensing control, codes ...MR1, ...MF1
max. 172

43.4

41

P
A

45
69.5

Pump axis
All control ports G1/4
Optional 7/16-20 UNF (option 3)

24

remote control port pP (code ...MRC, ...MR1) resp.


LS port pF (code ...MFC, ...MF1)

88.5

Controls with code ...MRC and MFC have no topside


valve interface (as shown above)
Dimensions horse power pilot cartridge, displacement sensor

45

73

37.5

Pump housing

56

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Control Dimensions

Dimensions for controls with unloading valve, codes ...M*W


43.4

All control ports G1/4


Optional 7/16-20 UNF
(option 3)

Pump axis
remote control port pP
resp. LS port pF

unloading valve:
D1VW002K*JW;
* for seals option

173

97

41

Shown in version MRW/MFW, version MMW has no remote control port.


Dimensions for controls with proportional pressure pilot valve, codes ...M*K
43.4

pilot valve:
PVACREC**35 for codes ...M*K,
** for threads and seals option

Pump axis
remote control port pP
resp. LS port pF

130

171

96

Shown in version MRK/MFK, version MMK has no remote control port.


Dimensions for horse power compensator *L* and *C* are identical to MM* respectively MF*.
57

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Control Dimensions

Dimensions two spool load sensing control, code ...MT1, ...MTP


LS port pF
88

96

pressure pilot valve


PVAC1PC**S35
(code ...MTP only)

110

Pump axis

191

pressure control
stage

104
80.5

58

29

displacement
control stage

elbow manifold

Dimensions two spool load sensing control with proportional pressure pilot valve, code ...MTK
LS port pF
88

96

pilot valve:
PVACREM**35 for code ...MTK,
** for threads- and seals soption

110

Pump axis
proportional
pressure pilot valve

222

pressure control
stage
116

105
81
58

29

elbow manifold
58

displacement
control stage
Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Control Dimensions

Dimensions proportional displacement control, code ...FDV


101,9

122,9

46,0

T
P
A

56,7
81,7

pump axis

Dimensions proportional p/Q-control, codes ...UDR, ...UDK, ...UDM


pressure pilot valve
(codes ...UDK, ...UDM only)

81
28

58

displacement
control stage

106

95

145

80

pilot valve:
PVACREM**35 for code ...UDK, UDM
** for threads- and seals option

59

108

elbow manifold

pump axis

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

113

222

106

pressure sensor
(code ...UDM only)
pressure
control stage

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Electronic Module PQDXXA


Features
Digital control circuit
Covers all displacements
Covers all available functions
Predefined parameter sets (Plug & Play)
Connection via USB cable (USB-A/USB-B)
Ramp time up to 60 seconds
Compatible to the relevant european EMC
specifications
Offline edition of parameter sets
Easy error diagnosis
Hands-on control tuning due to online monitoring of
PID gains
All settings (ramps, MIN/MAX, control parameters)
can be stored digitally and recalled from a PC to
dublicate settings to other modules
Technical data
Mounting style
Body material
Inflammation class
Mounting position
Env. temperature range
Protection class
Weight
Duty ratio
Supply voltage
Rush in current
Current consumption
Resolution Input Command
Interface
EMC
Connctors
Cables
Max. cable length

[C]
[g]
[%]
[V]
[A]
[A]
[%]

[mm]
[m]

Snap-on mounting for EN50022 rail


Polycarbonate
V2...V0 acc. UL 94
any
-20...+55
IP 20 acc. DIN 40 050
260
100
18...30VDC, ripple <5% eff.
22 for 0.2 ms
< 4 for p/Q control ; < 2 for Q-control
0.025 (power 0.1)
USB - Typ B
EN 50 081-2, EN 50 082-2
Screw terminals 0.2...2.5 mm, plug in style
Supply and solenoid cables; 1,5 mm2 (AWG16) overall braid shield.
Sensor and command signals; 0,5 mm2 (AWG20) overall braid shield
50

For programming the module via PC an interface cable is needed, please order part number PQDXXA-ZXX-KABEL separately.

Ordering code

PQD

XX

Z10

Digital control
module for p/Q
control

For all frame


sizes series PV

Version A

Option

Programming software
The programming of the p/Q control module is done in an
easy to learn mode. To select the pump model and size
and to set the control paramters the program ProPVplus
must be started. This program runs under WINDOWS
95 and higher.
The latest version of this software can be downloaded at
the following internet address:

www.parker.com/euro_pmd

Features
Display and documentation of parameter sets
Save ond reload of optimized parameter sets
Offers oscilloscope function for easy performance evaluation and optimization
Parameter sets for all PVplus pumps are pre-installed
in the modules
60

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Thru Drive, Mounting Kits

Mounting kits for multiple pumps, for second pump option

Code
1
2
3
4
5

MK

PV

Mounting
kit

Axial
piston
pump
series PV

BG
Size

Second pump Thread

Seals

Pump size
Pump size 1: PV016 - PV028
Pump size 2: PV032 - PV046
Pump size 3: PV063 - PV092
Pump size 4: PV140 - PV180
Pump size 5: PV270 - PV360

Code
T
Y
A
B
C
D
E
G
H
J
K
L
M

Kit contains positions 30, 69, 84,


85 and 87, see spare part list

Second pump, SAE


Prepared for thru drive option (plugged)
SAE AA, diameter 50.8 mm
SAE A, diameter 82.55 mm
SAE B, diameter 101.6 mm
SAE C, diameter 127,mm
SAE D, diameter 152.4 mm
SAE E, diameter 165.1 mm
Second pump, metric
Diameter 63 mm
Diameter 80 mm
Diameter 100 mm
Diameter 125 mm
Diameter 160 mm
Diameter 200 mm

Code

Seals

N
V

NBR
FPM

Code

Thread

M
S

Metric
SAE

Mounting kits for multiple pumps, couplings

Code
1
2
3
4
5

MK

PV

Mounting
kit

Axial
piston
pump
series PV

BG

K
Coupling

Size

Pump size

Code

Pump size 1: PV016 - PV028


Pump size 2: PV032 - PV046
Pump size 3: PV063 - PV092
Pump size 4: PV140 - PV180
Pump size 5: PV270 - PV360

SAE,
splined

01
02
03
04
05
06

Kit contains positions 1 (and 2 for keyed shaft).


keyed shaft
(only up to 18,
metric)

metric
splined

front pump

second pump

11
12
13
14
15
16
17
18

20
21
22

Coupling for metric,


splined shaft DIN 5480
N25 x 1.5 x 15
N32 x 1.5 x 20
N40 x 1.5 x 25
N50 x 2 x 24
N60 x 2 x 28
N70 x 3 x 22*
Coupling for SAE splined shaft
flat root, side fit
SAE A, 9T 16/32
SAE-, 11T 16/32
SAE B, 13T 16/32
SAE B-B, 15T 16/32
SAE C, 14T 12/24
SAE C-C, 17T 12/24
SAE D+E, 13T 8/16
SAE F, 15T 8/16
Coupling + adaptor
for keyed shaf
Diameter 12 mm
Diameter 16 mm
Diameter 18 mm

* For PV360 only

Availability of thru drive flange and coupling please check with ordering code options per each pump size, starting at page 6

61

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Thru Drive, Flange Load Limitation

Multiple Pump Combinations - Maximum Moment


Combinations of multiple pumps might require additional pump support to avoid a too high stress on the front m
ounting
flange. Combinations of two PVplus pumps in the same frame size generally do not need additional support in an
industrial application. For combinations of more pumps support is required.
In case of combinations of a PVplus pump with another type of pump it is recommended to calculate the moment
for the combination and compare with the maximum moment in table 1 below.
LP

L1

W1
W2

L2

W3

L3

Moment M = (L1*W1 + L2*W2 + L3*W3 +...)


Note:
If the calculated moment M exceed the maximum moment in table 1 below, additional pump support is needed
Table 1: Maximum Moment and Pump Dimensions
PV016-PV028
Maximum moment
Weight W

1)

PV032-PV046

PV063-PV092

PV140-PV180

PV270

PV360

[Nm]

81

151

401

591

1686

1686

[N]

186

294

589

883

1687

1766

Distance L1

[mm to C/G]

Distance Lp

[mm]

106

119

178

184

234

238

197.5

227

287

350

472.5

477

1) at dynamic weight acceleration 10g = 98.1 m/sec2

Table 2 Thru Drive Adapter Plate Thickness [mm]


Adapter option 2)

PV016-PV028

PV032-PV046

PV063-PV092

PV140-PV180

PV270

PV360

27

27

34

39

65

59

59

27

34

39

65

59

59

49

39

65

59

59

64

65

59

59

59

59

27

34

39

27

34

39

65

59

59

27

34

39

65

59

59

34

39

65

59

59

39

65

59

59

59

59

2) See page 6 to 17 for reference per each frame size.

62

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Axial Piston Pumps


Series PVplus

Catalogue HY30-3245/UK

Thru Drive, Shaft Load Limitations


Maximum allowed transferable torque FRONT
Shaft
code

Shaft
type

Transferable torque at FRONT shaft end. [Nm]


PV016-028

PV032-046

PV063-092

PV140-180

PV270

PV360

SAE - Key

300

650

1850

2150

2150

4750

SAE - Spline

320

630

1700

2750

2800

8100

SAE - Key

1200

SAE - Spline

1700

Metric - Key

3750

Metric - Spline

Metric - Key

280

640

1200

1550

3300

3750

Metric - Spline

320

720

1500

3050

5750

8100

1100

1550

3150

3250

8100

Maximum allowed transferable torque REAR


Max. torque transmission cap.
for rear mounted pump

350

520

Important notice
The max. allowable torque of the individual shaft must
not be exceeded. For 2-pump combinations there is no
problem because PV series offers 100% thru torque. For
3-pump combinations (and more) the limit torque could
be reached or exceeded.
Therefore it is necessary to calculate the resulting input
as well as thru drive torque.

WARNING USER RESPONSIBILITY


FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide
product or system options for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components
and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The
user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning
the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized
distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or
specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and
sufficient for all applications and reasonably foreseeable uses of the components or systems.

Offer of Sale
Please contact your Parker representation for a detailed Offer of Sale.

63

Parker Hannifin
Pump & Motor Division Europe
Chemnitz, Germany

Parker Worldwide
AE United Arab Emirates,
Dubai
Tel: +971 4 8127100
parker.me@parker.com
AT Austria, Wiener Neustadt
Tel: +43 (0)2622 23501-0
parker.austria@parker.com
AT Eastern Europe, Wiener
Neustadt
Tel: +43 (0)2622 23501 900
parker.easteurope@parker.com

HU Hungary, Budaoers
Tel: +36 23 885 470
parker.hungary@parker.com
IE Ireland, Dublin
Tel: +353 (0)1 466 6370
parker.ireland@parker.com
IT Italy, Corsico (MI)
Tel: +39 02 45 19 21
parker.italy@parker.com
KZ Kazakhstan, Almaty
Tel: +7 7273 561 000
parker.easteurope@parker.com

AZ Azerbaijan, Baku
Tel: +994 50 22 33 458
parker.azerbaijan@parker.com

NL The Netherlands, Oldenzaal


Tel: +31 (0)541 585 000
parker.nl@parker.com

BE/LU Belgium, Nivelles


Tel: +32 (0)67 280 900
parker.belgium@parker.com

NO Norway, Asker
Tel: +47 66 75 34 00
parker.norway@parker.com

BG Bulgaria, Sofia
Tel: +359 2 980 1344
parker.bulgaria@parker.com

PL Poland, Warsaw
Tel: +48 (0)22 573 24 00
parker.poland@parker.com

BY Belarus, Minsk
Tel: +48 (0)22 573 24 00
parker.poland@parker.com

PT Portugal, Leca da Palmeira


Tel: +351 22 999 7360
parker.portugal@parker.com

CH Switzerland, Etoy
Tel: +41 (0)21 821 87 00
parker.switzerland@parker.com

RO Romania, Bucharest
Tel: +40 21 252 1382
parker.romania@parker.com

CZ Czech Republic, Klecany


Tel: +420 284 083 111
parker.czechrepublic@parker.com

RU Russia, Moscow
Tel: +7 495 645-2156
parker.russia@parker.com

DE Germany, Kaarst
Tel: +49 (0)2131 4016 0
parker.germany@parker.com

SE Sweden, Spnga
Tel: +46 (0)8 59 79 50 00
parker.sweden@parker.com

DK Denmark, Ballerup
Tel: +45 43 56 04 00
parker.denmark@parker.com

SK Slovakia, Bansk Bystrica


Tel: +421 484 162 252
parker.slovakia@parker.com

ES Spain, Madrid
Tel: +34 902 330 001
parker.spain@parker.com

SL Slovenia, Novo Mesto


Tel: +386 7 337 6650
parker.slovenia@parker.com

FI Finland, Vantaa
Tel: +358 (0)20 753 2500
parker.finland@parker.com

TR Turkey, Istanbul
Tel: +90 216 4997081
parker.turkey@parker.com

FR France, Contamine s/Arve


Tel: +33 (0)4 50 25 80 25
parker.france@parker.com

UA Ukraine, Kiev
Tel: +48 (0)22 573 24 00
parker.poland@parker.com

GR Greece, Athens
Tel: +30 210 933 6450
parker.greece@parker.com

UK United Kingdom, Warwick


Tel: +44 (0)1926 317 878
parker.uk@parker.com
ZA South Africa, Kempton Park
Tel: +27 (0)11 961 0700
parker.southafrica@parker.com

North America
CA Canada, Milton, Ontario
Tel: +1 905 693 3000
US USA, Cleveland
(industrial)
Tel: +1 216 896 3000
US USA, Elk Grove Village
(mobile)
Tel: +1 847 258 6200

Asia Pacific
AU Australia, Castle Hill
Tel: +61 (0)2-9634 7777
CN China, Shanghai
Tel: +86 21 2899 5000
HK Hong Kong
Tel: +852 2428 8008
ID Indonesia, Tangerang
Tel: +62 21 7588 1906
IN India, Mumbai
Tel: +91 22 6513 7081-85
JP Japan, Fujisawa
Tel: +81 (0)4 6635 3050
KR South Korea, Seoul
Tel: +82 2 559 0400
MY Malaysia, Shah Alam
Tel: +60 3 7849 0800
NZ New Zealand, Mt Wellington
Tel: +64 9 574 1744
SG Singapore
Tel: +65 6887 6300
TH Thailand, Bangkok
Tel: +662 186 7000
TW Taiwan, New Taipei City
Tel: +886 2 2298 8987
VN Vietnam, Ho Chi Minh City
Tel: +84 8 3999 1600

South America
AR Argentina, Buenos Aires
Tel: +54 3327 44 4129
BR Brazil, Cachoeirinha RS
Tel: +55 51 3470 9144
CL Chile, Santiago
Tel: +56 2 623 1216
MX Mexico, Toluca
Tel: +52 72 2275 4200

Ed. 2015-04-21

Europe, Middle East, Africa

Catalogue HY30-3245/UK. POD, 07/2015, ZZ

2015 Parker Hannifin Corporation. All rights reserved.

EMEA Product Information Centre


Free phone: 00 800 27 27 5374
(from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL,
IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA)
US Product Information Centre
Toll-free number: 1-800-27 27 537

parker.com/pmde

Your local authorized Parker distributor

You might also like