Professional Documents
Culture Documents
Single-phase and
three-phase UPS
from 10 to 80 kVA
high reliability in harsh industrial environments
The solution for
> Industrial processes
> Services
> Medical
GAMME 140 A
Certifications
Advantages
Available
IP52
models
Process continuity
Frontal access for input/output cabling,
spares replacement and preventative
maintenance.
Scalable power and high availability (using
redundancy), with the facility to parallel up
to 6 units.
44
Complementary pages
> External battery cabinets,
page 82
MASTERYS IP+
from 10 to 80 kVA
Single-phase and three-phase UPS
Advantages
Extremely long lifetime: 15 years with virtually
unlimited cycling.
High-reliability No maintenance.
Wide temperature range up to 45 C.
Ultra rapid charging.
Battery-free, lead-free and environmentfriendly.
10
9
9
15
13.5
13.5
60
48
48
80
64
400V
20%(3) (up to -40% @ 50% of rated power)
50/60Hz
10%
0.99 / < 3%
1ph +N: 230V (can be configured 220/240 V)
3ph +N: 400 V (380/415 V configurable)(3)
1%
50/60Hz
2% (configurable from 1% to 8% with generating set)
< 1%
< 5%
125% for 10 minutes, 150% for 1 minute
3:1 (complying with IEC 62040-3)
up to 0.9 leading (up to 0.7 leading for 10minutes)
Rated voltage
Voltage tolerance
Rated frequency
Frequency tolerance
Total output voltage distortion - linear load
Total output voltage distortion - non-linear load
Overload
Crest factor
Power factor without derating
BYPASS
Rated voltage
Voltage tolerance
Rated frequency
Frequency tolerance
ENVIRONMENT
Operating ambient temperature
Relative humidity
Maximum altitude
Acoustic level at 1 m (ISO 3746)
UPS CABINET
Dimensions (3/1) W x D x H
Dimensions (3/3) W x D x H
Weight (3/1)
Weight (3/3)
Degree of protection
Colours
STANDARDS
Safety
EMC
Performance
Product declaration
2.5
IP+ 110
3/1
10
IP+ 310
3/3
10
IP+ 115
3/1
15
IP+ 315
3/3
15
IP+ 120
3/1
20
IP+ 320
3/3
20
IP+ 130
3/1
30
IP+ 330
3/3
30
IP+ 140
3/1
IP+ 340
3/3
IP+ 160
3/1
IP+ 360
3/3
IP+ 380
3/3
Electrical options
Technical data
Sn [kVA]
Pn [kW] - 3/1
Pn [kW] - 3/3
Parallel configuration(1)
INPUT
Rated voltage
Voltage tolerance
Rated frequency
Frequency tolerance
Power factor / THDI (2)
OUTPUT
MASTE 060 A GB
IN/OUT KVA
230 kg
230 kg
Long-life batteries.
External battery cabinet (degree of
protection up to IP32).
External temperature sensor.
Additional battery chargers.
A
dditional transformer.
P
arallel kit.
C
old start.
ACS synchronization system.
Neutral creation kit for mains without neutral.
Tropicalization and anti-corrosion protection
for electrical boards.
Standard communication
features
Multilanguage graphic display.
Dry contact interface.
MODBUS/JBUS RTU.
E
mbedded LAN interface (web pages,
email).
2
slots for communication options.
Communication options
Remote mimic panel.
Profibus.
MODBUS TCP.
N
ET VISION: professional WEB/SNMP
interface for UPS monitoring and shutdown
management of several operating systems.
Remote maintenance
T.SERVICE: maintenance software
for continuous 24/7 monitoring of the
SOCOMEC UPS.
(1) With transformer on input/bypass side. - (2) For source THDV <2% and nominal load.
(3) Three-phase 220-230-240 V from 15 to 40 kVA.
45