OUTDOOR UNIT
Table of contents
VRV,
the solution for the commercial
sector
22
Benefits
30
40
182
Control Systems
216
238
100
Hot water
Indoor units
176
Literature overview
257
166
VRV Intro
VRV
The solution for the commercial sector
Daikins VRV technology leads the way in
customisation to match individual commercial
building requirements in comfort and energy
efficiency. Flexible to cover all applications and
climate conditions, VRV has the unique products that
make the difference for you and your customers.
Supermarket
Store
Hotel
& shop
Office
Restaurant
Technical
Public
building
ARGUE CARDS
Unique outdoor unit range covering all applications and climate conditions
Unique products that make the difference
in efficiency
Variable Refrigerant Temperature leading to the highest seasonal efficiency
Round flow cassette with auto cleaning panel
in comfort
Variable Refrigerant Temperature preventing cold draughts
True continuous heating, during defrost
15 class units for small, well insulated rooms (cassette, wall, concealed ceiling models)
Low sound indoor and outdoor units
in design
Fully flat cassette, fully integrated in the ceiling
Daikin Emura, unique iconic design
in installation
Automatic refrigerant charge and refrigerant containment check
4-way blow ceiling suspended cassette (FXUQ)
plug & play Daikin air handling unit
Total solution incl. low and high temperature hydro box, Biddle air curtains, etc.
in control
Intelligent Touch manager cost-effiective mini BMS integrating all pillars
Easy integrating in third party BMS
Dedicated control solutions for applications such as technical cooling, shops, hotels, ...
Top reliability
The VRV air conditioning system is the worlds first individual air conditioning system with variable refrigerant flow control and was commercialised by Daikin in 1982.
VRV is the trademark of Dakin Industries Ltd, which is derived from the technology we call variable refrigerant volume.
VRV Intro
Ecological design
Ideal for reaching top BREEAM/EPDB levels
No more cold draughts with higher evaporation
temperatures up to 11 or 16C, making VRV IV an
ideal alternative to water-based systems
Unique specification for monovalent heating
Continuous comfort
VRV IV standards
Customize your VRV for best seasonal efficiency & comfort
Up to 28% higher seasonal efficiency (ESEER)
First weather dependent VRV
No more cold draft by supply of high outblow temperatures
VRV configurator
software for the fastest and most accurate commissioning,
configuration and customisation
Total solution
one supplier for heating, cooling, ventilation, hot water, Biddle air
curtains and control
combine both residential and VRV indoor units
Heat pump
Heat recovery
Replacement
Water cooled
ARGUE CARDS
Digital tools
Visit the website:
http://www.daikineurope.com/vrv-iv
Download simulation or selection software: Go to
extranet.daikineurope.com > Software downloads >
sales supporting apps
Solutions seasonal simulator
With this software tool you can simulate and
the seasonal efficiency, the annual power
consumption and CO2 emission for a given climate,
load profile (cooling, heating, heat recovery, covalent,
bivalent...) and (combination of ) system(s). With
its intuitive and graphical appealing interface, a
simulation can be made in a matter of minutes.
The solution basket system enables you to compare
joints
VRV Intro
Your References
Porta Fira
"This project reinforces Daikins position as a leader in the air
conditioning of large-scale structures, able to provide solutions that
stand out not only for their accuracy and reliability, but also for their
energy efficiency."
Heating
Cooling
Hot water
Underfloor heating
Air curtains
Ventilation
Controls
Refrigeration 3%
Lighting
Ventilation 4%
Integrate
third party
equipment
Kitchen
Office
Other
70%
Hot water 9%
Other
Office
equipment
48%
Lighting
Space cooling 9%
Space heating 31%
10
Ventilation 5%
Integrate
third party
equipment
VRV Intro
One system,
multiple applications for hotels, offices,
retail, home
Heating and cooling
Low-temperature hydrobox
Ventilation
11
VRV
for offices and banks
VRV
for hotels
22
22
Check on
https://www.youtube.com/
DaikinEurope
12
22
Check on
https://www.youtube.com/
DaikinEurope
VRV Intro
VRV
for retail
VRV
for residential use
22
22
22
Check on
https://www.youtube.com/
DaikinEurope
Which VRV
outdoor system offers me the best solution?
Heat recovery or heat pump?
VRV Heat recovery
North
Cooling
+
Hot water
Heating
Outdoor unit
Indoor unit
3-pipe
refrigerant
piping
Outdoor unit
14
Indoor unit
2-pipe
refrigerant
piping
South
VRV Intro
Outdoor unit
Indoor unit
Refrigerant piping
Water Cooled
Suitable for multi-storey and large buildings
because of the hardly unlimited possibilities of
water piping
Not affected by outdoor temperature/climate
conditions
Reduce CO2 emmisions thanks to the use of
geothermal energy as a renewable energy source
Allows heat recovery in the entire building thanks
to the storage of energy in the water circuit
Components:
Outdoor unit
Indoor unit
Refrigerant piping
(Geothermal)
water loop
15
Outdoor units
Products overview
VRV IV heat recovery
Model
Product name
Best efficiency & comfort solution
Fully integrated solution with heat recovery for maximum efficiency
Covers all thermal needs of a building via a single point of contact: accurate
temperature control, ventilation, hot water, air handling units and Biddle air
curtains
Free heating and hot water through heat recovery
The perfect personal comfort for guests/tenants via simultaneous cooling and
heating
Incorporates VRV IV standards & technologies such as
Variable Refrigerant temperature and continuous heating
Allows technical cooling
Widest range of BS boxes on the market
VRVIII-S
VRVIV-S
series
NEW
on efficiency
RYYQ-T
REYQ-T
accurate temperature control, ventilation, hot water, air handling units and
Biddle air curtains
Connectable to stylish indoor units (Daikin Emura, Nexura)
Incorporates VRV IV standards & technologies such as
Variable Refrigerant temperature and continuous heating
8 10 12 13 14 16 18 20 22 24 26 28 30
RXYQ-T
RXYSQP8V1/P8Y1
launch
autumn 2015
temperature
launch
autumn 2015
Compact
VRV Classic
heat recovery
heat pump
Replacement
VRVIV-S
series
Compact
NEW
RTSYQ-PA
RXYCQ-A
RQCEQ-P
RXYQQ-T
Water cooled
energy source
RWEYQ-T
16
Single unit
Multi combination
VRV Intro
HT Hydrobox HXHD-A
LT Hydrobox HXY-A
Remarks
O O
with LT Hydroboxes
O O O
O O O
O O O
Indoor units
Capacity (HP)
32 34 36 38 40 42 44 46 48 50 52 54 Description / Combination
O O O O
O O O O O O
O O O O O O
O O O O
O O O O
... connection of indoor unit possible, but not neccessarily simultaneously with other allowed indoor units
... connection of indoor unit possible even simultaneously with other checked units in the same row
O ... connection of indoor not possible on this outdoor unit system
17
Indoor units
Products overview
Type Model
Fully flat
cassette
FXZQ-A
2-way blow
ceiling
mounted
cassette
FXCQ-A
Ceiling
mounted
corner
cassette
FXKQ-MA
Small
concealed
ceiling unit
FXDQ-M9
Slim
concealed
ceiling unit
FXDQ-A
Concealed
ceiling unit
with medium
ESP
Slimmest yet most powerfull medium static pressure unit on the market!
Slimmest unit in class, only 245mm
Low operating sound level
Medium external static pressure up to 150Pa facilitates using flexible ducts of
varying lengths
Automatic air flow adjustment function measures the air volume and static
pressure and adjusts it towards the nominal air flow, guaranteeing comfort
FXSQ-A
Concealed
ceiling unit
with high ESP
UNIQUE
NEW
Ceiling suspended
Wall mounted
Concealed
ESP up to 270, ideal for extra large sized spaces
ceiling unit
Only grilles are visible
with high ESP Large capacity unit: up to 31.5 kW heating capacity
Floor standing
FXFQ-A
Round flow
cassette
Product name
UNIQUE
Concealed ceiling
Wall
mounted
unit
Ceiling
suspended
unit
UNIQUE
4-way blow
ceiling
suspended
unit
Floor
standing
unit
NEW
Concealed
floor
standing
unit
FXMQ-P7
FXMQ-MA9
FXAQ-P
For wide rooms with no false ceilings nor free floor space
Ideal for comfortable air flow in wide rooms thanks to Coanda effect
Rooms with ceilings up to 3.8m can be heated or cooled very easily!
Can easily be installed in both new and refurbishment projects
Can even be mounted in corners or narrow spaces without any problem
Reduced energy consumption thanks to DC fan motor
FXHQ-A
Unique Daikin unit for high rooms with no false ceilings nor free floor space
Rooms with ceilings up to 3.5m can be heated up or cooled down very easily!
Can easily be installed in both new and refurbishment projects
Flexibility to suit every room layout
Reduced energy consumption thanks to DC fan motor
FXUQ-A
FXLQ-P
FXNQ-A
1.7 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0
1.9 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5
(1) Nominal cooling capacities are based on: indoor temperature: 27CDB, 19CWB, outdoor temperature: 35CDB, equivalent refrigerant piping: 5m, level difference: 0m
(2) Nominal heating capacities are based on: indoor temperature: 20CDB, outdoor temperature: 7CDB, 6CWB, equivalent refrigerant piping: 5m, level difference: 0m
18
VRV Intro
overview
Depending on the application, Split and Sky Air
indoor units can be connected to our VRV IV
and VRV III-S outdoor units. Refer to the outdoor unit
portfolio for combination restrictions.
RXYSQ-P8Y13
Type
Model
Ceiling
mounted
cassette
Concealed
ceiling
Wall
mounted
Ceiling
suspended
Floor
standing
1
2
3
Product name
15
20
25
FCQG-F
35
42
50
60
71
RXYQ-T
RYYQ-T
RXYSQ-P8V13
Fully flat
cassette
FFQ-C
FDBQ-B
FDXS-F(9)
FBQ-D
Daikin Emura
Wall mounted unit
FTXG-LW/LS
CTXS-K
FTXS-K
FTXS-G
FHQ-C
FVXG-K
FVXS-F
FLXS-B(9)
19
Ventilation range
Five components of
indoor air quality
Ventilation
Heat recovery
Humidification
Air
processing
Filtration
Model
200
400 600
140,000
Components of
indoor air quality
VAM-FA/FB
Ventilation
Heat recovery
Heat reclaim
ventilation
VKM-GB
Ventilation
Heat recovery
Air processing
Air handling
units
VKM-GBM
DX total
fresh air
package
Ventilation
Heat recovery
Air processing
Humidification
Ventilation
Heat recovery
Air processing
Humidification
Filtration
Inverter technology
Heat pump and heat recovery
Provides virtually free heating
Room temperature via Daikin control
Large range of expansion valve kits
* Air flow rate is a calculated indication only, based on the following values: heating capacity EKEXV-kit * 200m/h
** Daikin AHU connected to Daikin chiller solution
20
**
Product name
CYV S/M/L-DK-F
CYV S/M/L-DK-C
CYV S/M/L-DK-R
VRV Intro
Additional options
A payback time of less than 1.5 years compared to
electrical air curtains
Easy and quick installation
Maximum energy efficiency thanks to rectifier
technology
85% air separation efficiency
Cassette model (C): mounted into a false ceiling
leaving only the decoration panel visible
Free-hanging model (F): easy wall mounted
installation
Recessed model (R) : neatly concealed in the ceiling
2.3
3.0
2.5
2.15
2.4
2.75
2.0
2.3
2.5
Favourable
Normal
Unfavourable
Location at a corner or
or open stairwell
Hydrobox range
Type
Product name
Model
HXY-A
Ideal for hot or cold water in underfloor, air handling units, low temperature
radiators
Hot/cold water from 5 to 45C
Large operation range (down to -20C and up to 43C)
Fully integrated water-side components save time on system design
Space saving contemporary wall hung design
HXHD-A
Ideal for hot water in bathrooms, sinks and for underfloor heating, radiators, air
handling units,
Hot water from 25 to 80C
"Free" heating and hot water through heat recovery
Uses heat pump technology to produce hot water efficiently, providing up to 17%
savings compared to a gas boiler
Possibility to connect thermal solar collectors
80
125
Leaving water
temperature range
5 C - 45 C
25 C - 80 C
Low
temperature
hydrobox
High
temperature
hydrobox
Network solutions
Type
Screen
Integration
Control
Monitoring
Options
Other
ITC
Layout screen
Touch screen
Mini BMS for heating, air conditioning applied systems and refrigeration units (BACnet and WAGO)
3rd party equipment integration (BACnet and WAGO)
Basic control functions: on/off, temp, setting, air flow sttings
Refrigerant containment check
Temperature limitation
Setback
Automatic changeover
Weekly schedule and special day pattern
Timer extension
Forced off
Basic control functions: ON/OFF status, operation mode, set point temp.
Filter status
Malfunction code
History (operation, malfunction)
Visualisation
PPD
Web access and control
HTTP option
Interlock
Pre-cool/heat
Sliding temperature
Free cooling
ACNSS connection Air Conditionning Network Service System
Maximum indoor unit groups
ITM
DMS-IF
BACNET
64
4x64
Std
64
2560
21
22
VRV IV
Standard & Technologies
VRV IV =
3 revolutionary standards
Variable refrigerant temperature
Continuous comfort during defrost
VRV configurator
23
Variable refrigerant
temperature
Cooling requirement
25
30
Adjust capacity by
Te control to meet
the load (avoid over
capacity and ON/OFF
operation)
35
Outdoor temperature
The lower the capacity need the higher the refrigerant temperature can be
Variable Te
Fixed Te
20
25
30
35
Outdoor temperature
Seasonal efficiency
Efficiency up
20
25
30
http://extranet.daikineurope.com/en/software/
downloads/solutions-seasonal-simulator/default.jsp
Success story
System
capacity
20
Daikin VRV IV
Variable Refrigerant Temperature control for energy
saving in partial load condition.
The capacity is controlled by the inverter compressor
AND variation of the evaporating (Te) and
condensing (Tc) temperature of the refrigerant in
order to achieve the highest seasonal efficiency.
Design point
The colder it gets, the lower the load on the building and the lower the capacity need
Refrigerant temperature
in cooling (evaporating
temperature)
35
Outdoor temperature
VRV IV
Standard & Technologies
Different modes to
maximise efficiency
and comfort
Check on
https://www.youtube.com/
DaikinEurope
Step 1
Step 2
Automatic*
Quick reaction speed
Powerful
Top efficiency
High sensible
(User selection)
Basic
Mild *
Quick
Mild
Eco
No submodes
te nt s
Quick
Powerful
Top efficiency
6
pa
This is how most other VRF systems work and can be used for all general type of
applications. Suitable for computer rooms.
Suitable for low ceiling rooms.
* Factory setting
Avg (kWh/Month)
2.797
1.502
Total (KWh)
33.562
18.023
Total ()
6.041
3.244
9,9
5,3
Period
Yearly (operation
cost/m (/m)
Measured data
Fashion store Unterhaching (Germany)
Floor space: 607m
Energy cost: 0,18 /kWh
System taken into account for consumption:
- VRV IV heat pump with continuous heating
- Round flow cassettes (without auto cleaning panel)
- VAM for ventilation (2x VAM2000)
- Biddle Air curtain.
25
Continuous heating
during defrost
Check on
https://www.youtube.com/
DaikinEurope
Room temperature
VRV IV
VRF benchmark
Time
Alternate defrost
while indoors
a comfortable temperature
is maintained.
26
even checken in de
infographics map: ik denk
dat er een tekening van
een VRV bestaat
VRV IV
Standard & Technologies
Configurator
software
Check on
https://www.youtube.com/
DaikinEurope
Simplified commissioning
The VRV configurator is an advanced software
solution that allows for easy system configuration
and commissioning:
less time is required on the roof configuring the
outdoor unit
multiple systems at different sites can be managed
in exactly the same way, thus offering simplified
commissioning forkey accounts
initial settings on the outdoor unit can be easily
retrieved.
Simplified
commissioning
Simplified servicing
Outdoor unit display for quick on-site settings and
easy read out of errors together with the indication of
service parameters for checking basic functions.
easy-to-read error report
clear menu indicating quick and easy on-site
settings
indication of basic service parameters to quickly
check basic functions: high pressure, low
pressure, frequency ans operation time history of
compressors, temperature of discharge/suction
pipe.
27
Unique VRV IV
core technologies
Newly developed
37
compressor
patents
High efficiency J-type 6-pole motor
Full inverter
Enabling variable refrigerant temperature and low
efficiency
start-up currents
Stepless capacity control
Thixocasting process
Refrigerant-cooled PCB
Reliable cooling because it is not influenced by
patents
efficiency
28
10
patents
Target
Predictive Control
Function (PCF)
Reaches the target capacity/refrigerant temperature
faster
Reaches the target without overshooting, so there is
no waste, leading to improved efficiency
Three capacity settings give more precise control
for user comfort
The large number of Daikin systems already in
operation and which are monitored by our i-Net
software put us in the unique position of being
able to analyse this data and develop the predictive
compressor control function.
General VRF:
Double time against VRV IV
2t
(VRV IV)
(general VRF)
Half time
against
general
VRF
DC fan motor
UNIQUE
Outer rotor DC motor for higher efficiency
DC fan motor
Stator
Stator
Rotor
I-demand function
In 85C
In 85C
43C
55C
27C
55C
27C
60C
50C
55C
Out 45C
Out 45C
Power consumption
Predefined limit
Time
29
VRV IV
Standard & Technologies
UNIQUE
Waste
compressor
operation
30
Benefits
VRV
Latest technology, highest efficiency
VRV, a total commercial solution
Drastically reducing your running costs
32
Top reliability
32
Up to 6 times greater resistance against corrosion 32
Comfort guaranteed at all times
37
Maximum flexibility
36
38
38
31
ON
ON
OFF
ON
OFF
Performed tests:
VDA Wechseltest
Contents of 1 cycle (7 days):
24 hours salt spray test SS DIN 50021
96 hours humidity cycle test KFW
DIN 50017
Aluminium
Heat exchanger
Corrosion-resistant
Acrylic resin
Degree
of corrosion
8
7
6
5
4
3
2
1
0
1 2 3 4 5
Cycle
Bare aluminium
DAIKIN P.E.
Degree of
corrosion
10
9
8
7
6
5
4
3
2
1
0
1 2 3 4 5 6 10 20 30 40 50 60 70
Cycle
32
Benefits
ALL
Sequential Start
Up to 3 outdoor units can be connected to 1 power
supply and can be turned on sequentially. This allows
the number of breakers and their capacities to remain
small and simplifies wiring (for models of 10HP or less).
1 v/d 2 kiezen
Top quality
Only brazed connections
Flare or flange
33
Cooling
Time
VRV SERIES (DAIKIN indoor unit (PID controlled))
Note: The graph shows the data, measured in a test room assuming
actual heating load. The thermostat can control stable room
16
Room temperature
Continuous heating
During defrost
Indoor comfort not effected via the unique heat
accumulating element or alternate defrost
The best alternative to traditional heating systems
VRV IV
VRF benchmark
Time
Back-up function
In the event of a compressor malfunction another
compressor or outdoor unit will take over in order
to maintain 8 hour interim capacity, allowing time
for maintenance or repair while comfort remains
guaranteed.
Single outdoor unit
with multiple compressors
34
Benefits
db(A)
Perceived loudness
Treshold of hearing
Sound
-
20
Extremely soft
Rustling leaves
40
Very soft
Quiet room
60
Moderately loud
Normal conversation
80
Very loud
100
Extremely loud
Symphonic orchestra
120
Threshold of feeling
emura
19dB(A)
25.5dB(A)
10 hrs
50%
Capacity* %
Load %
Operation Sound dBA
Night mode
58 dBA
Step 1: 50dB
Step 2: 45dB
50dBA
45 dBA
<
35
Maximum flexibility
dan met
vloeistof
oelt af...
-20C
52C
-25C
Cooling mode
Heating mode
With the technical cooling function, the operation range in cooling of the heat recovery system is
extended from -5C to -20C1, making it perfect for integrating server rooms.
VRV IV example
Total piping length
Longest length actual (Equivalent)
1000m
165m (190m)
1 v/d 2 kiezen
indoor and outdoor units
Level difference between indoor units
90m1
90m1
even checken in de
infographics map: ik denk
dat er een tekening van
een VRV bestaat
1 v/d 2 kiezen
even checken in de
infographics map: ik denk
dat er een tekening van
een VRV bestaat
even checken in de
infographics map: ik denk
dat er een tekening van
een VRV bestaat
30m
Indoor installation
Push button
on the PCB
even checken in de
infographics map: ik denk
dat er een tekening van
een VRV bestaat
ush button
n the PCB
36
15.5C
ESP up to
78pa
Multiple tenants,
one outdoor unit
The multi tenant function ensures that the entire VRV
system does not shut down when the main power
supply of an indoor is switched off.
This means that the indoor units main power supply
can be turned off when a part of the building is
closed,is being serviced without affecting the rest of
the building.
Benefits
operation
in holiday
in service
operation
multi tenant
No structural
reinforcement necessary
Thanks to the vibration-free and sufficient light
construction of the outdoor units, floors do not need
to be reinforced, reducing the overall cost of the
building when compared to a chiller.
Phased installation
Installation of the VRV system can be implemented
floor by floor, so that sections of the building can
be put into use very quickly, or enabling the air
conditioning system to be commissioned and
operated in stages, rather than on final completion of
the project.
Under construction
VRV system
Installation
floor by floor
37
1 v/d 2 kiezen
Calculate extra
Check on regular
Stop manually
refrigerant volume
filling process
to check weight of
Manual
refrigerant
Automatic
Push button
on the PCB
Connect bottle
Filling procedure
stops automatically:
charging function
close valves
R410-A
10% undercharged
calculation:
2.2 kg extra refrigerant required
0.5 kg
Real installation
76 m refrigerant piping
Easy compliance to
F-gas regulation
When activating the refrigerant containment check, the unit switches into cooling
mode and duplicates certain reference conditions based on memory data.
The result indicates whether or not refrigerant leakage has occurred.
The refrigerant volume of the complete system is calculated for the following data:
Outdoor temperature
Reference system temperatures
Reference pressure temperatures
Refrigerant density
Types and number of indoor units
Not available on VRVIII-S or in combination when one or more RA indoor units, hydroboxes, are connected
Next to remote checking, the function can also be activated on-site via a push button on the PCB.
38
1 v/d 2 kiezen
Benefits
push buttons
1 v/d 2 kiezen
Compact design
The compact design of the outdoor units is sufficient
to allow them to be taken up to the top of a
building in a commercial elevator, overcoming site
transportation problem, particularly when outdoor
units need to be installed on each floor.
foto in crkeltje zou ik
behouden
Push button
on the PCB
Push button
on the PCB
R410-A
REFNET joint
T-joint
REFNET joint
REFNET
header
Daikin Europe N.V. advises only to use Daikin REFNET piping system.
40
Overview of
functions
VRVIV
Heat
recovery
VRVIV
heat
pump with
continous
heating
VRVIV
heat pump
without
continous
heating
VRV III-S
VRV III-C
VRV
Classic
Replacement
VRVIV
heat pump
Replacement
VRV III
Heat
recovery
Water
cooled
VRVIV
p 44
p 54
p 54
p 62
p 70
p 76
p 81
p 81
p 92
Continuous heating
(heat accumulating element)
Continuous heating
(alternate defrost)
VRV configurator
7 segment indicator
Automatic refrigerant charge
Refrigerant containment check
Night quiet mode
Low noise function
Connectable to stylish indoor units
(Daikin Emura, Nexura)
41
VRV Outdoor
EIFFAGE OFFICE,
VRV IV WITH CONTINUOUS HEATING
VRV-S SERIES
PARK PHI
BREEAM EXCELLENT OFFICE
BUILDING WATERCOOLED VRV
42
VRV Outdoor
43
22
Air curtain
te c h n
Control systems
Ventilation
Heat Reclaim ventilation (VAM/VKM)
AHU connection kit
7 segment indicator
Automatic refrigerant charge
Refrigerant containment check
Night quiet mode
VRV IV standards:
Variable refrigerant
temperature
Customize your VRV for best seasonal
efficiency & comfort
Continuous heating
DC fan motor
VRV configurator
I demand function
3-pipte
ology
North
Cooling
Hot water
+
South
Heating
Improved efficiency
Maximum comfort
A VRV heat-recovery system allows simultaneous
cooling and heating.
For hotel owners, this means a perfect
environment for guests as they can freely
choose between cooling or heating.
For offices, it means a perfect working indoor
climate for both north and south-facing offices.
Cooling load
Improved mix
mode control
Optimised Partition
of Heat Exchanger for
highest seasonal efficiency
in heat recovery mode
Ambient
temperature
Heating load
30%
70%
Wide heating
operation range
VRV IV heat recovery has a standard operation range
down to -20C in heating.
It can also provide cooling down to -20C for
technical server rooms (field setting).
-20
-15
-10
-5
-20
-15
-10
-5
-20CWB
15
15
15.5C
Heating
-25
-20
-25C
-20CWB
-25
-20
-15
-10
-5
43 45
-5CWB
-15
-10
Technical Cooling
-5
43CDB
43 45
Cooling
45
Advantages
of 3-pipe technology
More free heat
Pressure
Condensing 55 C
Condensing 45 C
Pressure
2-pipe system
Pipe length
1000m
165m (190m)
90m1
90m1
30m
46
90m maximum
Fully redesigned
BS boxes
Maximum design flexibility
and installation speed
Quickly and flexibly design your system with a
Outdoor Unit Product Range
Single port
Unique to the market
Compact and light to install
No drain piping needed
Ideal for remote rooms
Technical cooling function
Connect up to 250 class unit (28 kW)
Allows multi-tenant applications
Multi port: 4 6 8 10 12 16
Up to 55% smaller and 41% lighter than
previous range
Faster installation thanks to a reduced number
of brazing points and wiring
All indoor units connectable to one BS box
Fewer inspection ports needed
Up to 16 kW capacity available per port
Connect up to 250 class unit (28kW) by
combining 2 ports
No limit on unused ports, permitting
phased installation
BS 4 Q14 A
BS 6, 8 Q14 A
BS 10, 12 Q14 A
BS 16 Q14 A
Maximum comfort at
all times
With the VRV BS box, any indoor unit not being used
to switch between heating and cooling maintains
the constant desired temperature. This is because
our heat recovery system does not need to equalise
pressure over the entire system after a change-over.
Off
47
REYQ-T
efficiency!
Covers all thermal needs of a building via a single point of
contact: accurate temperature control, ventilation, hot water, air
handling units and Biddle air curtains
Free heating and hot water through heat recovery
The perfect personal comfort for guests/tenants via
simultaneous cooling and heating
Outdoor system
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
Nom.
Nom.
Max.
Cooling
Heating
REYQ
HP
kW
kW
kW
kW
kW
kW
Nom.
Nom.
Max.
EER
COP - Max.
COP - Nom.
ESEER
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Fan
Air flow rate
Cooling
Nom.
Sound power level
Cooling
Nom.
Sound pressure level
Cooling
Nom.
Night
Level 1
Quiet
Level 2
Mode
Level 3
Operation range
Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type / GWP
Charge
Piping connections
Liquid
OD
Gas
OD
Discharge gas
OD
Total piping length
System
Actual
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
Outdoor system
System
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
kg/TCO2
mm
mm
mm
m
Hz/V
A
REYQ
HP
kW
kW
kW
kW
kW
kW
Nom.
Nom.
Max.
EER
COP - Max.
COP - Nom.
ESEER - Automatic
ESEER - Standard
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Piping connections
Liquid
OD
Gas
OD
Discharge gas
OD
Total piping length
System
Current - 50Hz
Maximum fuse amps (MFA)
Continuous heating
48
mm
kg
m/min
dBA
dBA
dBA
dBA
dBA
CDB
CWB
Actual
mm
mm
mm
m
A
8T
8
22.4
22.4
25.0
5.31
4.75
5.51
4.22
4.54
4.72
7.41
10T
10
28.0
28.0
31.5
7.15
6.29
7.38
3.92
4.27
4.45
7.37
12T
12
33.5
33.5
37.5
9.23
8.05
9.43
3.63
100
200
260
125
250
325
1,685x930x765
218
175
79
58
58
54
52
150
300
390
4.17
7.05
64 (1)
175
350
455
185
304
223
9.8/20.5
9.9/20.7
210
162
78
56
55
53
9.7/20.2
14T
14
40.0
40.0
45.0
10.7
9.60
11.3
3.74
3.98
4.16
6.84
81
61
58
54
52
58
52
47
-5.0~43.0
-20~15.5
R-410A / 2,087.5
9.52
19.1
15.9
18T
18
50.4
50.4
56.5
15.2
12.3
14.3
3.32
3.95
4.10
6.26
20T
20
56.0
56.0
63.0
18.6
14.9
17.5
3.01
3.60
3.76
5.68
200
225
400
450
520
585
1,685x1,240x765
305
260
251
86
64
65
58
60
52
52
47
48
250
500
650
22.2
1,000
3N~/50/380-415
32
25
162.5
325.0
422.5
18T
REYQ8T
REYQ10T
18
50.4
50.4
56.5
12.46
11.04
12.89
4.04
4.38
4.57
7.38
5.98
200
400
520
225
450
585
12.7
28.6
19.1
22.2
500
40
20T
261
88
66
60
52
48
15.9
28.6
22.2
19.1
20
337
11.8/24.6
12.7
10T
13T
16T
REMQ5T
REMQ5T
REYQ8T
10
13
16
28.0
36.4
44.8
28.0
36.4
44.8
32.0
41.0
50.0
6.34
8.48
10.62
5.42
7.46
9.50
6.50
8.76
11.02
4.42
4.29
4.22
4.92
4.68
4.54
5.17
4.88
4.72
7.77
7.54
7.41
6.55
6.36
6.25
125
250
325
9.52
22.2
16T
16
45.0
45.0
50.0
12.8
11.2
12.9
3.52
3.88
4.02
6.63
28.6
40
50
22T
24T
26T
28T
30T
32T
REYQ10T REYQ8T
REYQ12T
REYQ16T
REYQ12T
REYQ16T REYQ14T REYQ16T REYQ18T REYQ16T
20
22
24
26
28
30
32
55.9
61.5
67.4
73.5
78.5
83.9
90.0
55.9
61.5
67.4
73.5
78.5
83.9
90.0
62.5
69.0
75.0
82.5
87.5
94.0
100.0
14.54
16.38
18.11
19.93
22.03
24.43
25.6
12.80
14.34
15.95
17.65
19.25
20.35
22.4
14.94
16.81
18.41
20.73
22.33
23.73
25.8
3.84
3.75
3.72
3.69
3.56
3.43
3.52
4.18
4.10
4.07
3.98
3.92
3.96
3.88
4.37
4.29
4.23
4.16
4.08
4.12
4.02
7.06
7.07
6.87
6.95
6.72
6.48
6.63
5.68
5.54
5.46
5.41
5.23
5.03
5.14
64
250
275
300
325
350
375
400
500
550
600
650
700
750
800
650
715
780
845
910
975
1,040
15.9
19.1
34.9
28.6
1,000
50
63
80
v
REYQ-T
Outdoor system
System
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
REYQ
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Nom.
Nom.
Max.
Cooling
Heating
HP
kW
kW
kW
kW
kW
kW
Nom.
Nom.
Max.
EER
COP - Max.
COP - Nom.
ESEER - Automatic
ESEER - Standard
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Piping connections
Liquid
OD
Gas
OD
Discharge gas
OD
Total piping length
System
Current - 50Hz
Maximum fuse amps (MFA)
Continuous heating
34T
36T
REYQ16T
REYQ18T REYQ20T
34
36
95.4
101.0
95.4
101.0
106.5
113.0
28.0
31.4
23.5
26.1
27.2
30.4
3.41
3.22
3.92
3.72
4.06
3.87
6.43
6.06
4.97
4.70
425
850
1,105
Actual
mm
mm
mm
m
A
450
900
1,170
38T
40T
42T
REYQ8T
REYQ10T
REYQ12T
REYQ18T
38
40
42
106.3
111.9
118.0
106.3
111.9
118.0
119.0
125.5
131.5
29.74
31.58
32.75
25.10
26.64
28.69
29.24
31.11
33.18
3.57
3.54
3.60
4.07
4.03
3.96
4.24
4.20
4.11
6.66
6.68
6.79
5.25
5.20
5.28
475
950
1,235
500
1,000
1,300
525
1,050
1,365
34.9
28.6
80
44T
46T
REYQ12T REYQ14T
REYQ16T
REYQ16T
44
46
123.5
130.0
123.5
130.0
137.5
145.0
34.83
36.3
30.45
32.00
35.23
37.1
3.55
3.58
3.90
3.91
4.06
6.68
6.75
5.20
5.23
64
550
575
1,100
1,150
1,430
1,495
19.1
41.3
34.9
1,000
100
48T
50T
REYQ16T
52T
48
135.0
135.0
150.0
38.4
33.6
38.7
3.52
3.88
4.02
6.63
5.14
50
140.4
140.4
156.5
40.8
34.7
40.1
3.44
3.90
4.05
6.49
5.03
54T
REYQ18T
REYQ18T
REYQ18T
52
54
145.8
151.2
145.8
151.2
163.0
169.5
43.2
45.6
35.8
36.9
41.5
42.9
3.38
3.32
3.93
3.95
4.07
4.10
6.37
6.26
4.93
4.84
600
1,200
1,560
625
1,250
1,625
650
1,300
1,690
675
1,350
1,755
125
v
REMQ
mm
kg
m/min
dBA
dBA
CDB
CWB
kg/TCO2Eq
Hz/V
A
5T
1,685x930x765
210
162
77
56
-5.0~43.0
-20~15.5
R-410A / 2,087.5
9.7/20.2
3N~/50/380-415
20
(1) Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, RA indoor, etc.) and the connection ratio restriction for the system (50% <= CR <= 130%) (2) Technical cooling setting, refer to the installation manual for
more information
49
Detail A
70
106
AC
125
107
66
160
353
134
112
729
100
AA
AB
339
Detail B
10
4-15x22.5mmOblong hole
Foundation bolt hole
View C
1685
11
122
179
131
276
259
515
Model
AA
RYYQ8T, RXYQ8T, RXYQQ8T
248
RYYQ10-12T, RXYQ10-12T, RXYQQ10-12T 195
RYMQ8T
248
REMQ5T, RYMQ10-12T, REYQ8-12T
195
76
76
97
137
DETAIL B
DETAIL A
765
Notes
107
328
373
1. Detail A and detail B indicate the dimensions after fixing the attached piping.
2. Items 4 - 10:
Knockout hole.
930
Liquid pipe
RYYQ8-10T, RYMQ8-10T, RXYQ8-10T, RXYQ
9.5 brazing connection
Q8-10T, REMQ5T, REYQ8-12T
:
RYYQ12T, RYMQ12T, RXYQ12T, RXYQQ12T : 12.7 brazing connection
11
10
9
8
7
6
5
4
AC
240
240
272
3. Gas pipe
RYYQ8T, RYMQ8T, RXYQ8T, RXYQQ8T
: 19.1 brazing connection
RYYQ10T, RYMQ10T, RXYQ10T, RXYQQ10T : 22.2 brazing connection
REMQ5T, REYQ8-12T
:
25.4 brazing connection
RYYQ12T, RYMQ12T, RXYQ12T, RXYQQ12T : 28.6 brazing connection
Equalising pipe
RYMQ8-10T :
RYMQ12T :
AB
208
208
3
2
1
No.
Grounding terminal
Pipe routing hole (bottom)
Pipe routing hole (front)
65
27
65
80
65
See note 3.
See note 3.
See note 3.
Part name
Remark
2D079532B
REYQ14-20T
REYQ14-20T
106
160
393
134
107
112
125
70
729
AB
192
310
71
100
10
AA
Detail B
Detail A
View C
1685
11
122
DETAIL B
Notes
DETAIL A
107
328
C
1240
Liquid pipe
RYYQ14-16T, RYMQ14-16T, RXYQ14-16T, RXYQQ14-16T, REYQ14-20T : 12.7 brazing connection
AB
205
210
272
373
1. Detail A and detail B indicate the dimensions after fixing the attached piping.
2. Items 4 - 10:
Knockout hole.
AA
240
240
131
97
137
765
50
179
276
76
76
3. Gas pipe
REYQ14-20T
259
515
Model
RYMQ14-16T, RXYQQ14-16T, REYQ14-20T
RYMQ18-20T, RXYQQ18-20T
Equalising pipe
RYMQ14-16T
RYMQ18-20T
11
10
9
8
7
6
5
4
3
Grounding terminal
65
27
65
80
65
See note 3.
See note 3.
See note 3.
Remark
2D079533B
REYQ-T
<Pattern1>
<Pattern1>
<Pattern1>
300 or more
300 or more
<Front>
300 or more
300 or more
REYQ-T
For single unit installation
<Pattern1>
<Pattern1>
300 or more
<Pattern2>
100 or more
50 or more
20 or more
10 or more
10 or more
<Pattern2>
50 or more 50 or more
<Front>
500 or more
100 or more
<Pattern3>
<Pattern3>
300 or more
Wall height
unrestricted
<Pattern2>
<Pattern2>
100 or more
50 or more
<Front>
<Front>
20 or
more
500 or more
500 or more
Wall height
unrestricted
<Front>
200 or more
500 or more
100 or more
10 or more
400 or more
200 or more
<Front>
400 or more
10 or more
<Front>300 or20more
or more
50 or
more
300 or more
<Front>
500 or more
<Front>
20 or more
50 or more
500 or more
500 or more
100 or more
300 or more
10 or more
<Front>
500 or more
10 or more 10 or more
<Front>
500 or more
100 or more
20 or more
10 or more
20 or more
50 or
more
10 or more
<Front>
500 or more
100
or more
50 or more
10 or more
10 or more
<Front>
100 or more
50 or
more
50 or
more
10 or more
20 or more
100 or more
50 or more
20 or more
<Front>
100 or more
50 or more
<Front>
500 or more
100 or more
50 or more
50 or more
100 or more
100
or more
<Front>
500 or more
100 or more
50 or more
50 or more
100 or more
50 or more 50 or more
10 or more
500
or more
10 or more
20 or more
20 or more
<Front>
900 or more
10 or more
<Front>
50 or more
500 or more
50 or more 50 or more
<Front>
100
or more
500 or more
<Front>
20 or more
100
or more
50 or
more
10 or more
20 or more
300 or more
10 or more
10 or more
<Front>
<Front>
50 or more
50 or more
100
or more
50 or more
500 or more
10 or more
400 or more
20 or more
600 or more
100
or more
<Pattern2>
200 or more
300 or more
<Front>
200 or more
<Front>
<Pattern2>
600 or more
400 or more
10 or more
50 or
<Front> 20 or100
moreor more 10 or
<Front>
more 10 or more
more
500 or more
<Pattern3>
300 or more
<Front>
100
300orormore
more
or more
50 or more 10 or100
50 or10more
or more
more
<Pattern3>
100 or more
500 or more
<Pattern1>
<Suction side>
<Front>
500 or more
20 or more
<Front>group
20 or more
For
centralized
layout10 or more
10 or more
10 or more
<Front>
10 or more
300 or more
<Front>
500 or more
100 or more
100 or more
900 or more
500 or more
100 or more
10 or more
10 or more
500 or more
600 or more
50 or
more
<Front>
50 or
more
10 or more
500 or more
<Unit: mm>
500 or more
600 or more
50 or
more
<Front>
50 or
more
500 or more
500 or more
<Unit: mm>
<Suction side>
<Front>
NOTES
NOTES
3D079542
3D079542
51
REYQ-T
BS1Q-A
Cooling
Nom.
Heating
Nom.
Maximum number of connectable indoor units
Maximum capacity index of connectable indoor units
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Casing
Material
Piping connections
Outdoor unit
Liquid
Type/OD
Gas
Type/OD
Discharge gas Type/OD
Indoor unit
Liquid
Type/OD
Gas
Type/OD
Sound absorbing thermal insulation
Power supply
Phase/Frequency/Voltage
Total circuit
Maximum fuse amps (MFA)
BS1Q-A
BS
kW
kW
1Q10A
1Q16A
0.005
0.005
5
15 < x 100
1Q25A
8
100<x160
207x388x326
mm
kg
160<x250
12
15
mm
mm
mm
mm
mm
Hz/V
A
Brazing connection/22.2
Brazing connection/19.1
Brazing connection/22.2
BS-Q14A
wiring
Cooling
Nom.
Heating
Nom.
Maximum number of connectable indoor units
Maximum number of connectable indoor units per branch
Number of branches
Maximum capacity index of connectable indoor units
Maximum capacity index of connectable indoor units per branch
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Casing
Material
Piping connections
Outdoor unit
Liquid
OD
Gas
OD
Discharge gas OD
Indoor unit
Liquid
OD
Gas
OD
Drain
Sound absorbing thermal insulation
Power supply
Phase/Frequency/Voltage
Total circuit
Maximum fuse amps (MFA)
52
BS
kW
kW
BS6,8Q14A
4Q14A
0.043
0.043
20
6Q14A
0.064
0.064
30
8Q14A
0.086
0.086
40
4
400
6
600
10Q14A
0.107
0.107
50
12Q14A
0.129
0.129
60
16Q14A
0.172
0.172
64
12
16
5
10
750
140
mm
kg
298x370x430
17
24
mm
mm
mm
mm
mm
9.5
22.2 / 19.1
19.1 / 15.9
12.7
28.6 / 22.2
19.1 / 22.2
Hz/V
A
298x580x430
298x820x430
26
35
38
Galvanised steel plate
12.7 / 15.9
15.9
15.9 / 19.1
28.6
28.6 / 34.9
19.1 / 22.2 / 28.6
28.6
9.5 / 6.4
15.9 / 12.7
VP20 (I.D. 20/O.D. 26)
Urethane foam, polyethylene foam
1~/50/220-440
15
298x1,060x430
50
19.1
34.9
BSVQ-P9B
Indoor unit
Power input
Cooling
Nom.
Heating
Nom.
Maximum number of connectable indoor units
Maximum capacity index of connectable indoor units
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Casing
Material
Piping connections
Outdoor unit
Liquid
Type/OD
Gas
Type/OD
Discharge gas Type/OD
Indoor unit
Liquid
Type/OD
Gas
Type/OD
Sound absorbing thermal insulation
Power supply
Phase/Frequency/Voltage
Total circuit
Maximum fuse amps (MFA)
BSVQ
kW
kW
100P9B
160P9B
0.005
0.005
6
15 < x 100
Hz/V
A
250P9B
8
100<x160
207x388x326
mm
kg
mm
mm
mm
mm
mm
BSVQ-P9B
160<x250
12
15
Brazing connection/22.2
Brazing connection/19.1
Brazing connection/22.2
BSV4Q-PV/BSV6Q-PV
and wiring
indoor units
Indoor unit
Power input
BSV4Q-PV/BSV6Q-PV
Cooling
Nom.
kW
Heating
Nom.
kW
Maximum number of connectable indoor units
Maximum number of connectable indoor units per branch
Number of branches
Maximum capacity index of connectable indoor units
Maximum capacity index of connectable indoor units per branch
Dimensions
Unit
HeightxWidthxDepth
mm
Weight
Unit
kg
Casing
Material
Piping connections
Outdoor unit
Liquid
Type/OD
mm
Gas
Type/OD
mm
Discharge gas Type/OD
mm
Indoor unit
Liquid
Type/OD
mm
Gas
Type/OD
mm
Sound absorbing thermal insulation
Power supply
Phase/Frequency/Voltage
Hz/V
Total circuit
Maximum fuse amps (MFA)
A
BSV4Q100PV
4Q100PV
0.020
0.020
24
6Q100PV
0.030
0.030
36
6
4
400
6
600
100
209x1,053x635
60
209x1,577x635
89
Galvanised steel plate
Brazing connection/12.7
Brazing connection/15.9
Brazing connection/28.6
Brazing connection/19.1
Brazing connection/28.6
Brazing connection/9.5
Brazing connection/15.9
Foamed polyurethane Flame-resistant needle felt
1~/50/220-240
15
53
Indoor units
VRV type indoor units
Residential type indoor units
(such as Daikin Emura)
Hot water
Low temperature hydrobox
Control systems
Ventilation
Heat Reclaim ventilation (VAM/VKM)
AHU connection kit
7 segment indicator
Automatic refrigerant charge
Refrigerant containment check
Night quiet mode
VRV IV standards:
Variable refrigerant
temperature
Customize your VRV for best seasonal
efficiency & comfort
Continuous heating
DC fan motor
VRV configurator
54
FXSQ-A
VRV indoor unit
FXFQ-A
VRV indoor unit
FVXG-K
Nexura
BPMKS967A2
FTXG-LW
Daikin Emura
20 CLASS
25 CLASS
35 CLASS
FTXG20LW
FTXG20LS
FTXG25LW
FTXG25LS
FTXG35LW
FTXG35LS
FTXS20K
FTXS25K
FTXS35K
CTXS35K
FVXG25K
FVXG35K
FVXG50K
FVXS25F
FVXS35F
FVXS50F
FLXS25B
FLXS35B9
FLXS50B
CTXS15K
42 CLASS
50 CLASS
60 CLASS
71 CLASS
FTXS60G
FTXS71G
FTXG50LW
FTXG50LS
FTXS42K
FTXS50K
FLXS60B
55
VRV IV
proven in practice:
40% more efficient
A field trial at a German fashion chain store
demonstrated how the innovative features
of VRV IV have improved energy efficiency
dramatically over previous models.
Average daily
consumption
during working
hours in kWh
220
210
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
-2
-1
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Avg (kWh/Month)
2.797
1.502
Total (KWh)
33.562
18.023
Total ()
6.041
3.244
9,9
5,3
Period
Yearly (operation
cost/m (/m)
25
26
Measured data
Fashion store Unterhaching (Germany)
Floor space: 607m
Energy cost: 0,18 /kWh
System taken into account for consumption:
- VRV IV heat pump with continuous heating
- Round flow cassettes (without auto cleaning panel)
- VAM for ventilation (2x VAM2000)
- Biddle Air curtain.
Free combination of
outdoor units
Freely combine outdoor units to optimise for
small footprint, continuous heating, highest
efficiency or any other combination
1000m
165m (190m)
90m1
90m1
30m
90m maximum
57
RYYQ-T / RXYQ-T
Outdoor system
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
Nom.
Nom.
Max.
Cooling
Heating
RYYQ/RXYQ
HP
kW
kW
kW
kW
kW
kW
Nom.
Nom.
Max.
EER
ESEER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Fan
Air flow rate
Cooling
Nom.
Sound power level
Cooling
Nom.
Sound pressure level
Cooling
Nom.
Cooling
Level 1
Cooling
Level 2
Cooling
Level 3
Operation range
Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type / GWP
Charge
Piping connections
Liquid
OD
Gas
OD
Total piping length
System
Actual
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
Outdoor system
System
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
kg/TCO2Eq
mm
mm
m
Hz/V
A
RYYQ / RXYQ
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Nom.
Nom.
Max.
Cooling
Heating
HP
kW
kW
kW
kW
kW
kW
Nom.
Nom.
Max.
EER
ESEER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Piping connections
Liquid
OD
Gas
OD
Total piping length
System
Current - 50Hz
Maximum fuse amps (MFA)
58
mm
kg
m/min
dBA
dBA
dBA
dBA
dBA
CDB
CWB
Actual
mm
mm
m
A
8T
10T
12T
14T
16T
18T
20T
8
10
12
14
16
18
20
22.4
28.0
33.5
40.0
45.0
50.4
56.0
22.4
28.0
33.5
40.0
45.0
50.4
56.0
25.0
31.5
37.5
45.0
50.0
56.5
63.0
5.21
7.29
8.98
11.0
13.0
15.0
18.5
4.75
6.29
7.77
9.52
11.1
12.6
14.5
5.51
7.38
9.10
11.2
12.8
14.6
17.0
4.30
3.84
3.73
3.64
3.46
3.36
3.03
6.37 (1) / 7.53 (2) 5.67 (1) / 7.20 (2) 5.50 (1) / 6.96 (2) 5.31 (1) / 6.83 (2) 5.05 (1) / 6.50 (2) 4.97 (1) / 6.38 (2) 4.42 (1) / 5.67 (2)
4.72 (3) / 4.54 (4) 4.45 (3) / 4.27 (4) 4.31 (3) / 4.12 (4) 4.20 (3) / 4.02 (4) 4.05 (3) / 3.91 (4) 4.00 (3) / 3.87 (4) 3.86 (3) / 3.71 (4)
64 (5)
100
125
150
175
200
225
250
200
250
300
350
400
450
500
260
325
390
455
520
585
650
1,685x930x765
1,685x1,240x765
261
268
364
398
162
175
185
223
260
251
261
78
79
81
86
88
58
61
64
65
66
56
58
58
58
58
60
60
55
54
54
52
52
52
52
53
52
52
47
47
48
48
-5~43
-20~15.5
R-410A / 2,087.5
5.9/12.3
6/12.5
6.3/13.2
10.3/21.5
10.4/21.7
11.7/24.4
11.8/24.6
9.52
12.7
15.9
19.1
22.2
28.6
1,000
3N~/50/380-415
20
25
32
40
50
22T
10
12
24T
8
16
26T
28T
12
16
30T
32T
34T
16
18
36T
38T
8
14
18
16
20
10
20
22
24
26
28
30
32
34
36
38
61.5
67.4
73.5
78.5
83.5
90.0
95.0
101.0
106.0
61.5
67.4
73.5
78.5
83.5
90.0
95.0
101.0
106.4
69.0
75.0
82.5
87.5
93.5
100.0
106.0
113.0
119.5
16.27
18.2
20.0
22.0
23.7
26.0
27.7
31.5
31.0
14.06
15.85
17.29
18.87
20.17
22.2
23.5
25.6
25.54
16.48
18.31
20.30
21.90
23.50
25.6
27.2
29.8
29.89
3.77
3.70
3.68
3.57
3.52
3.46
3.43
3.21
3.42
5.58 (1) / 7.07 (2) 5.42 (1) / 6.81 (2) 5.39 (1) / 6.89 (2) 5.23 (1) / 6.69 (2) 5.17 (1) / 6.60 (2) 5.05 (1) / 6.50 (2) 5.01 (1) / 6.44 (2) 4.68 (1) / 6.02 (2) 5.03 (1) / 6.36 (2)
4.37 (3) / 4.19 (4) 4.25 (3) / 4.10 (4) 4.25 (3) / 4.06 (4) 4.16 (3) / 4.00 (4) 4.14 (3) / 3.98 (4) 4.05 (3) / 3.91 (4) 4.04 (3) / 3.90 (4) 3.95 (3) / 3.79 (4) 4.17 (3) / 4.00 (4)
64 (5)
275
300
325
350
375
400
425
450
475
550
600
650
700
750
800
850
900
950
715
780
845
910
975
1,040
1,105
1,170
1,235
15.9
19.1
28.6
34.9
41.3
1,000
63
80
100
RYYQ8-12T
RXYQ8-12T
Outdoor system
System
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
RYYQ / RXYQ
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Nom.
Nom.
Max.
Cooling
Heating
42T
10
HP
kW
kW
kW
kW
kW
kW
Nom.
Nom.
Max.
EER
ESEER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Piping connections
Liquid
OD
Gas
OD
Total piping length
System
Current - 50Hz
Maximum fuse amps (MFA)
40T
Actual
mm
mm
m
A
RYMQ
mm
kg
m/min
dBA
dBA
CDB
CWB
kg/TCO2Eq
Hz/V
A
44T
12
46T
14
16
48T
50T
16
52T
54T
18
12
18
18
16
18
40
42
44
46
48
50
52
54
111.5
118.0
123.5
130.0
135.0
140.0
145.0
150.0
111.5
118.0
123.5
130.0
135.0
140.0
145.0
150.0
125.0
131.5
137.5
145.0
150.0
156.0
162.0
168.0
31.0
33.3
35.0
37.0
39.0
40.7
42.4
44.1
26.46
28.49
29.97
31.72
33.3
34.6
35.9
37.2
30.88
32.98
34.70
36.8
38.4
40.0
41.6
43.2
3.61
3.54
3.51
3.46
3.44
3.42
3.40
5.29 (1) / 6.74 (2) 5.19 (1) / 6.65 (2) 5.17 (1) / 6.62 (2) 5.13 (1) / 6.60 (2) 5.05 (1) / 6.50 (2) 5.02 (1) / 6.46 (2) 4.99 (1) / 6.42 (2) 4.97 (1) / 6.38 (2)
4.21 (3) / 4.05 (4) 4.14 (3) / 3.99 (4) 4.12 (3) / 3.96 (4) 4.10 (3) / 3.94 (4) 4.05 (3) / 3.91 (4) 4.05 (3) / 3.90 (4) 4.04 (3) / 3.89 (4) 4.03 (3) / 3.89 (4)
64 (5)
500
525
550
575
600
625
650
675
1,000
1,050
1,100
1,150
1,200
1,250
1,300
1,350
1,300
1,365
1,430
1,495
1,560
1,625
1,690
1,755
19.1
41.3
1,000
100
125
8T
188
162
78
10T
1,685x930x765
195
175
79
58
5.9/12.3
6/12.5
20
25
12T
14T
185
223
16T
18T
1,685x1,240x765
309
81
61
6.3/13.2
-5~43
-20~15.5
R-410A / 2,087.5
10.3/21.5
3N~/50/380-415
32
20T
319
260
251
64
65
261
88
66
10.4/21.7
11.7/24.4
11.8/24.6
86
40
50
(1) The STANDARD ESEER value corresponds with normal VRV4 Heat Pump operation, not taking into account advanced energy saving operation functionality
(2) The AUTOMATIC SEER value corresponds with normal VRV4 Heat Pump operation, taking into account advanced energy saving operation functionality ( variable refrigerant temperature control operation) (3) COP nominal;
(4) COP maximum (5) Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, RA indoor, etc.) and the connection ratio restriction for the system (50% <= CR <= 130%)
59
Detail A
70
106
AC
125
107
66
160
353
134
112
729
100
AA
AB
339
Detail B
10
4-15x22.5mmOblong hole
Foundation bolt hole
View C
1685
11
122
259
179
131
276
515
Model
RYYQ8T, RXYQ8T, RXYQQ8T
RYYQ10-12T, RXYQ10-12T, RXYQQ10-12T
RYMQ8T
REMQ5T, RYMQ10-12T, REYQ8-12T
76
76
97
137
DETAIL B
Notes
328
373
930
11
10
9
8
7
6
5
4
Liquid pipe
RYYQ8-10T, RYMQ8-10T, RXYQ8-10T, RXYQ
Q8-10T, REMQ5T, REYQ8-12T
:
RYYQ12T, RYMQ12T, RXYQ12T, RXYQQ12T :
Equalising pipe
RYMQ8-10T :
RYMQ12T :
3
2
1
No.
AC
240
240
272
1. Detail A and detail B indicate the dimensions after fixing the attached piping.
2. Items 4 - 10:
Knockout hole.
3. Gas pipe
RYYQ8T, RYMQ8T, RXYQ8T, RXYQQ8T
:
RYYQ10T, RYMQ10T, RXYQ10T, RXYQQ10T :
REMQ5T, REYQ8-12T
:
RYYQ12T, RYMQ12T, RXYQ12T, RXYQQ12T :
AB
208
208
107
DETAIL A
765
AA
248
195
248
195
Grounding terminal
Pipe routing hole (bottom)
Pipe routing hole (front)
65
27
65
80
65
See note 3.
See note 3.
See note 3.
Part name
Remark
2D079532B
106
160
393
134
107
112
125
70
71
100
AB
192
310
729
10
AA
Detail B
Detail A
View C
1685
11
122
179
131
276
76
76
97
137
DETAIL B
765
Notes
DETAIL A
107
272
328
373
1. Detail A and detail B indicate the dimensions after fixing the attached piping.
2. Items 4 - 10:
Knockout hole.
3. Gas pipe
REYQ14-20T
259
515
Model
RYMQ14-16T, RXYQQ14-16T, REYQ14-20T
RYMQ18-20T, RXYQQ18-20T
1240
25.4 brazing connection
Liquid pipe
RYYQ14-16T, RYMQ14-16T, RXYQ14-16T, RXYQQ14-16T, REYQ14-20T :
Equalising pipe
RYMQ14-16T
RYMQ18-20T
11
10
9
8
7
6
5
4
3
Grounding terminal
Pipe routing hole (front)
Power cord routing hole (bottom)
Power cord routing hole (front)
Power cord routing hole (front)
Power cord routing hole (front)
Power cord routing hole (side)
Equalising pipe connection port
65
27
65
80
65
See note 3.
2
1 Liquid pipe connection port
No. Part name
Gas pipe connection port
60
See note 3.
See note 3.
Remark
2D079533B
AA
240
240
AB
205
210
RYYQ-T
RYMQ-T
RXYQ-T
RYYQ-T
RXYQQ-T
/ RXYQ-T
300 or more
(Pattern 1)
300 or more
10 or
more
(FRONT)
500 or more
(Pattern 2)
10 or
more
20 or more
(FRONT)
500 or more
20 or more
10 or more 10 or more
300 or more
(FRONT)
600 or more
20 or more
(FRONT)
500 or more
20 or more
10 or more
10 or more
(FRONT)
500 or more
10 or more
10 or more
300 or more
(FRONT)
20 or more
10 or more 10 or more
500 or more
10 or more
20 or more
900 or more
(Pattern 2)
100 or more
50 or more
300 or more
(FRONT)
500 or more
100 or more
50 or
more 50 or more
(Pattern 3)
300 or more
(FRONT)
200 or more
10 or more
20 or more
10 or more
10 or more
20 or more
(FRONT)
500 or more
10 or more
(Pattern 2)
100 or more
(Pattern 3)
Wall height
unrestricted
(FRONT)
500 or more
100 or more
50 or more
100 or
more
50 or more
300 or more
400 or more
200 or more
(FRONT)
400 or more
50 or more
(FRONT)
500 or more
(FRONT)
500 or more
100 or more
100 or more
100 or
more
50 or
more 50 or more
100 or
more
50 or more
50 or more
(FRONT)
(FRONT)
500 or more
100 or more
50 or more
50 or more
100 or more
500 or more
600 or more
50 or more
10 or more
300 or more
100 or more
50 or more 50 or more
100 or more
(FRONT)
500 or more
50 or more
<Suction side>
<Front>
<Unit = mm>
NOTES
3D079542
61
Indoor units
VRV type indoor units
Residential type indoor units
(such as Daikin Emura, ...)
Control systems
62
Ventilation
Heat Reclaim ventilation (VAM/VKM)
AHU connection kit
1,685mm
Volume:
Footprint:
320mm
900mm
930mm
FXZQ-A
FXSQ-A
FXAQ-P
BPMKS967A2
BPMKS967A2
FVXG-K - Nexura
20 CLASS
NEW
FFQ25C
FDBQ25B
FDXS25F
25 CLASS
CTXS15K
35 CLASS
FCQG35F
FFQ35C
FVXG25K
FVXS25F
FDXS35F
FBQ35D
FTXG35LW
FTXG35LS
FTXS35K
CTXS35K
FHQ35C
FVXG35K
FVXS35F
FLXS25B
FLXS35B9
FTXG20LW
FTXG20LS
FTXG25LW
FTXG25LS
FTXS20K
FTXS25K
42 CLASS
FTXS42K
50 CLASS
FCQG50F
FFQ50C
60 CLASS
FCQG60F
FFQ60C
FDXS50F9
FBQ50D
FTXG50LW
FTXG50LS
FDXS60F
FBQ60D
FTXS50K
FTXS60G
FHQ50C
FVXG50K
FVXS50F
FHQ60C
FLXS50B
FLXS60B
71 CLASS
FTXS71G
For more info about Daikins stylish indoor units, please check our indoor unit-portfolio
* VRV indoor units and stylish indoor units cannot be combined.
* To connect stylish indoor units a BPMKS unit is needed
63
Cooling
3.991
4.552
Heating
0 1 2 3 4 5
2m
15m
40m
40m
64
5m
50m (40m1)
30m
15m
15m
40m maximum
250m
300m
150m (175m)
Stylish indoors
connected
VRV indoors
connected
Advanced technologies
Conventional
New
3. e-Bridge circuit
Prevents accumulation of liquid refrigerant in the
condenser.This results in more efficient use of
the condenser surface under all conditions and
leads in turn to better energy efficiency. Increased
evaporative capacity stems from
the newly developed refrigeration circuit, the SCebridge circuit, which adds super cooling prior to the
expansion cycle. By adopting this circuit, the COPs
in both coolingand heating have been drastically
improved.
Current
Evaporativecapacity
Evaporative capacity
can be raised by taking
super cooling just
before the electronic
expansion valve
By the SCe- bridge
circuit, cooling and
heating attain the
improvement in COP
SCe-Bridge Circuit
65
VRV IV S-series
Space saving solution without
compromising on efficiency
Preliminary
4-5 HP
4-5-6-8-10-12 HP
66
RXYSQ-P8V1/RXYSQ-P8Y1
controlled
Outdoor unit
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
Nom.
Nom.
Cooling
Heating
Nom.
Nom.
EER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Fan
Air flow rate
Cooling
Nom.
Sound power level
Cooling
Nom.
Sound pressure level Cooling
Nom.
Heating
Nom.
Operation range
Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type / GWP
Charge
Piping connections
Liquid
OD
Gas
OD
Total piping length
System
Actual
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
RXYSQ
HP
kW
kW
kW
kW
RXYSQ-P8V / RXYSQ-P8Y
4P8V1
4
12.6
14.2
3.24
3.12
3.89
4.55
8 (1) / 8 (2)
50
5P8V1
5
14.0
16.0
3.51
3.86
3.99
4.15
10 (1) / 9 (2)
62.5
6P8V1
6
15.5
18.0
4.53
4.57
3.42
3.94
12 (1) / 9 (2)
70
130
162.5
182
4P8Y1
4
12.6
14.2
3.33
3.21
3.78
4.42
8 (1) / 8 (2)
50
5P8Y1
5
14.0
16.0
3.61
3.97
3.88
4.03
10 (1) / 9 (2)
62.5
6P8Y1
6
15.5
18.0
4.66
4.70
3.33
3.83
12 (1) / 9 (2)
70
130
162.5
182
66
50
52
67
51
53
69
53
55
mm
kg
m/min
dBA
dBA
dBA
CDB
CWB
kg/TCO2Eq
mm
mm
m
Hz/V
A
1,345x900x320
120
106
66
50
52
67
51
53
15.9 / 19.1
300 / 115
300 / 135
1N~/50/220-240
32.0
69
53
55
-5~46
-20~15.5
R-410A / 2,087.5
4.0/8.4
9.52
19.1
15.9 / 19.1
300 / 145
300 / 115
300 / 135
3N~/50/380-415
16.0
19.1
300 / 145
(1) In case VRV indoor units are connected (2) In case RA indoors are connected
67
1
2
3
4
5
6
7
8
MODEL
A
With RA connection
RXYSQ4P8V1
19.1 Brazing
15.9 Flare
RXYSQ5P8V1
19.1 Brazing
15.9 Flare
RXYSQ6P8V1
19.1 Brazing
19.1 Brazing
3TW30374-1B
RXYSQ-P8Y1
RXYSQ-P8Y1
1
2
3
4
5
6
7
8
68
MODEL
A
With RA connection
RXYSQ4P8Y1
19.1 Brazing
15.9 Flare
RXYSQ5P8Y1
19.1 Brazing
15.9 Flare
RXYSQ6P8Y1
19.1 Brazing
19.1 Brazing
3TW30374-1B
ss
r le
0o
50
1000 or more
A
250
300
10
0o
rm
ore
10
0o
10
ore
LH
H>L
ore
rm
0o
rm
00
10
or
or
re
mo
re
20
0o
rm
ore
r
0o
ore
rm
o
00
50
les
0o
0o
50
s
les
LH
H<L
L
A
0 < L 1/2 H
250
1/2 H < L H
300
Set the stand as: L H
Refer to the column of L H for A
ss
r le
0o
50
re
mo
r
0o
10 re
mo
0
50 more
or
rm
ore
15
0o
r
0o
15
rm
ore
00
or
LH
1000 or more
0o
10
H<L
re
20
0o
ore
ore
e
0
20 mor
or
00 e
10 mor
or
1000 or more
1/2 H < L H
1250
Set the stand as: L H
LH
H<L
L
A
0 < L 1/2 H
250
1/2 H < L H
300
Can not be installed
ore
rm
0o
Pattern 2
00
15 more
or
or
re
mo
e
0
10 mor
or
30
10
00 e
20 mor
or
0
50 less
or
ore
rm
0o
50
ore
rm
0o
25
H<L
e
0
30 mor
or
rm
o
00
rm
mo
re
mo
r le
o
00
L
A
0 < L 1/2 H
750
1/2 H < L H
1000
Set the stand as: L H
or
r
0o
30 re
mo
00
10 more
or
s
r le
50
L>H
re
mo
00
10
Drain piping
construction dimension
0o
1000 or more
15
re
mo
or
00
15 more
or
4. Double-decker installation
(a) Obstacle on the discharge side
1000 or more
10
00 e
10 mor
or
L>H
ss
r le
0o
50
Pattern 1
mo
1000 or more
00
L
A
0 < L 1/2 H
100
1/2 H < L H
200
Set the stand as: L H
10
00
15 more
or
1000 or more
50
les
r
0o
1000 or more
1000 or more
50
Drain piping
construction dimension
10
ore
rm
0o
re
mo
r
0o
0
60 more
or
00
30 more
or
LH
ore
rm
0o
50
ore
rm
0o
10
3D045696D
69
VRVIII-C
VRV heat pump
Indoor units
VRV type indoor units
Control systems
70
Ventilation
Heat Reclaim ventilation (VAM/VKM)
AHU connection kit
ump
at p
he
dard
2.00
Stan
1.00
0.00
-25
-20
-15
-10
-5
Outdoor temp. (WB)
10
Heating mode
Cooling mode
VRVIII-C
Standard VRV
-25CWB
-20CWB
15.5C
Outdoor Temp.
Outdoor Temp.
(kW) 35
30
heating capacity
43CDB
-5C
25
20
15
10
5
0
-25
-20
-15
-10
-5
0
Outdoor temp. (CWB)
Heating capacity 10HP outdoor unit
10
71
60
50
30
30
25
20
10
20
50% reduction
-10
-20
Indoor temperature C
40
-5
5 6
10
Elapsed time (min.)
Indoorpositie
temperatureblauwe
VRVIII-C
lijnen:
15
14 15
20
X +10
10m
40m (90m1)
50m (40m)
72
30m
90m maximum
500m
165m (190m)
RTSYQ-PA
Heating
capacity
High
Liquid injection
Gas-liquid
separator
Middle
Pressure
Gas injection
Low
Input power
Evaporator capacity
Enthalpy
Outdoor system
System
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
RTSYQ
Outdoor unit module 1
Outdoor unit module 2
Function unit
Nom.
Nom.
Cooling
Heating
Nom.
Nom.
EER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Sound pressure level
Cooling
Max./Nom.
Piping connections
Liquid
OD
Gas
OD
Oil equalizing
OD
Total piping length
System
Actual
Current - 50Hz
Maximum fuse amps (MFA)
Outdoor unit module
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Fan
Air flow rate
Cooling
Nom.
Sound power level
Cooling
Nom.
Operation range
Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type / GWP
Charge
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
10PA
RTSQ10PAY1
14PA
RTSQ14PAY1
-
10
28.0
31.5 / 28.0
7.90
7.78 / 8.18
3.54
4.05 / 3.42
21
125
250
325
62/60
9.52
22.2
14
40.0
45.0 / 40.0
12.6
11.4 / 12.8
3.17
3.95 / 3.13
30
175
350
455
63/61
16PA
RTSQ16PAY1
20PA
RTSQ8PAY1
RTSQ12PAY1
16
45.0
50.0 / 45.0
14.9
13.0 / 15.0
3.02
3.85 / 3.00
34
200
400
520
20
56.0
63.0 / 55.9
15.4
15.4 / 18.7
3.64
4.09 / 2.99
43
250
500
650
BTSQ20PY1
HP
kW
kW
kW
kW
dBA
mm
mm
mm
m
A
mm
kg
m/min
dBA
CDB
CWB
kg/TCO2Eq
Hz/V
A
65/63
12.7
15.9
28.6
19.1
500
25
35
BTSQ20P
1,570x460x765
110
-
RTSQ8PA
9.4/19.6
20
40
RTSQ10PA
1,680x930x765
205
RTSQ12PA
257
185
200
-5~43
-25~15.5
R-410A / 2,087.5
10.5/21.9
10.9/22.8
3~/50/380-415
25
50
RTSQ14PA
RTSQ16PA
1,680x1,240x765
338
344
233
239
11.7/24.4
35
40
73
Outdoor unit
NOTES
300 or more
(Pitch of foundation
bolt holes)
10 or more
10 or more
(Front)
500 or more
Function unit
500mm
<Suction side>
<Front>
1500mm
50~100mm
System
Outdoor unit
DWG. No.
Function unit
DWG. No.
RTSYQ10PA
RTSQ10PA
3D076289
BTSQ20P
3D060838
3D076286
RTSYQ14,16PA
RTSYQ14,16PA
500mm
<Suction side>
<Front>
300 or more
(Pitch of foundation bolt holes)
Outdoor unit
1500mm
NOTES
10 or more
(Front)
500 or more
Function unit
System
Outdoor unit
DWG. No.
Function unit
DWG. No.
RTSYQ14PA
RTSQ14PA
3D076291
BTSQ20P
3D060838
RTSYQ16PA
RTSQ16PA
3D076291
BTSQ20P
3D060838
10 or more
3D076287
74
(Pitch of foundation
bolt holes)
Outdoor unit 2
Outdoor unit 1
RTSYQ-PA
20mm
300 or more
20 or more
50~100mm
10 or more
<Front>
10 or more
50 or more
500 or more
<Front>
10 or more
20 or more
10 or more
<Suction side>
20 or more
300 or
more
50 or more
500 or more
500 or more
<Front>
10 or more
50 or more
500mm
<Front>
<Front>
100 or more
50 or more
10 or more
20 or more
600 or more
100 or more
1500mm
50 or
more
300 or more
500 or more
<Front>
10 or more
300 or more
10 or more
(Front)
20 or more
10 or
more
Function unit
300 or more
< Pattern 1 >
10 or more
NOTES
(Pitch of foundation
bolt holes)
20 or more
10 or more
20 or more
System
Outdoor unit 1
DWG. No.
100 or more
RTSQ12PA
3D076290
RTSYQ20PA
Outdoor unit 2
10 or more
RTSQ8PA
DWG. No.
Function unit
100 or more
3D076290
10 DWG.
or more
BTSQ20P
No.
3D060838
3D076288
300 or more
RTSYQ-PA
RTSYQ-PA
50 or more
<Front>
400 or more
<Front>
50 or more
10 or more
100 or more
500 or more
200 or more
<Front>
50 or more
500 or more
50 or more
100 or more
<Front>
200 or more
50 or more
10 or more
<Front>
100 or more
500 or more < Pattern 1 >
50 or more
100 or more
100 or more
10 or more
10 or more
50 or more
50 or more
10 or more
50 or more
<Front>
10 or more
20 or more
600 or more
50 or more
10 or more
10 or more
<Front>
20 or more
<Front>
500 or more
50 or more
20 or more
300 or
more
50 or more
500 or more
100 or more
<Front>
10 or more
100 or more
10 or more
50 or
more
<Front>
500 or more
500mm
20 or more
300 or more
10 or
more
300 or more
1500mm
300 or more
20 or more
10 or more
10 or more
20 or more
50 or more
10 or more
10 or more
100 or more
100 or more
300 or more
50 or more
400 or more
<Front>
<Front>
100 or more
500 or more
200 or more
50 or more
10 or more
50 or more
<Front>
500 or more
50 or more
100 or more
<Front>
200 or more
100 or more
10 or more
3D059348C
100 or more
50 or more
1.
2.
If the above wall heights are exceeded then h2/2 and h1/2 should be added to the front and suction side service spaces respectively as shown in the figure on the right.
3.
When installing the units most appropriate pattern should be selected from those shown above in order to obtain the best fit in the space available always bearing in mind the need to leave
enough space for a person to pass between units and wall and for the air to circulate freely. (If more units are to be installed than are catered for in the above patterns your layout should take
account of the possibility of short circuits.)
4.
The units should be installed to leave sufficient space at the front for the on site refrigerant piping work to be carried out comfortably.
5.
Installation of snowbreak hood (field supply; ask you dealer for details) is recommended in case there expected an effect from snow and space between outdoor unit and function unit is more
than 100 mm.
50 or more
500mm
50 or more
100 or more
<Front>
500 or more
1500mm
50 or more
NOTES
75
RTSYQ20PA
Indoor units
VRV type indoor units
Ventilation
Heat Reclaim ventilation (VAM/VKM)
Control systems
Benefits
For projects with standard cooling & heating
requirements
Fits any building as also indoor installation is
possible as a result of high external static pressure
of up to 78.4 Pa. Indoor installation leads to less
piping length, lower installation costs, increased
efficiency and better visual aesthetics
The ability to control each conditioned zone
300m
135m (155m)
40m (90m1)
30m
15m
77
RXYCQ-A
VRV Classic
Classic VRV configuration
For standard cooling & heating requirements
Connectable to all standard VRV indoor units, controls and
ventilation
RXYCQ14-20A
Outdoor unit
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
Nom.
Nom.
Cooling
Heating
Nom.
Nom.
EER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Fan
Air flow rate
Cooling
Nom.
Sound power level
Cooling
Nom.
Sound pressure level
Cooling
Nom.
Operation range
Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type / GWP
Charge
Charge
Piping connections
Liquid
OD
Gas
OD
Total piping length
System
Actual
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
78
RXYCQ
HP
kW
kW
kW
kW
mm
kg
m/min
dBA
dBA
CDB
CWB
kg
TCO2Eq
mm
mm
m
Hz/V
A
8A
8
20.0
22.4
6.60
5.80
3.03
3.86
10A
10
25.0
28.0
6.74
7.00
3.71
4.00
100
200
200
1,680x635x765
159
95
78
58
125
250
250
6.2
12.9
15.9
187
171
59
7.7
16.1
9.52
19.1
12A
12
30.0
33.6
8.77
8.62
3.42
3.90
150
300
360
1,680x930x765
240
185
81
61
8.4
17.5
14A
14
35.0
37.5
11.4
9.74
3.07
3.85
64
175
350
420
16A
16
40.0
44.8
12.9
11.8
3.10
3.80
200
400
480
196
-5~43
-20~15.5
R-410A / 2,087.5
8.6
18
22.2
64
18A
18
45.0
50.4
15.0
13.8
3.00
3.65
225
450
540
1,680x1,240x765
316
233
86
65
11.3
23.6
12.7
11.5
24
28.6
300
3N~/50/380-415
16
25
40
20A
20
50.4
56.5
17.9
16.1
2.81
3.50
250
500
600
324
239
88
66
17.7
24.4
15.9
(knock-out hole)
(knock-out hole)
(knock-out hole)
No.
1
2
3
4
5
6
7
8
9
10
(knock-out hole)
Parts name
Liquid pipe connection port
Gas pipe connection port
Grounding terminal
Power cord routing hole (side)
Power cord routing hole (front)
Power cord routing hole (front)
Power cord routing hole (bottom)
Wire routing hole (front)
Pipe routing hole (front)
Pipe routing hole (bottom)
NOTES
Remarks
9.5 Brazing connection
15.9 Brazing connection
Inside of switch box (M8)
62
45
27
50
27
1. Detail for front side and detail for bottom side indicate the dimensions
after fixing the attached piping.
3D080764
RXYCQ10-14A
RXYCQ10-14A
(Pitch of foundation
bolt holes)
(for 10HP)
(knock-out hole)
(knock-out hole)
(knock-out hole)
(knock-out hole)
No.
1
2
3
4
5
6
7
8
9
10
Parts name
Liquid pipe connection port
Gas pipe connection port
Grounding terminal
Power cord routing hole (side)
Power cord routing hole (front)
Power cord routing hole (front)
Power cord routing hole (bottom)
Wire routing hole (front)
Pipe routing hole (front)
Pipe routing hole (bottom)
(knock-out hole)
Remarks
See note 2
See note 2
Inside of switch box (M8)
62
45
27
65.5
27
NOTES
1. Detail for front side and detail for bottom side indicate the dimensions after fixing the
attached piping.
2. Gas pipe:
19.1 Brazing connection: RXYCQ10
22.2 Brazing connection: RXYCQ12
28.6 Brazing connection: RXYCQ14
Liquid pipe:
9.5 Brazing connection: RXYCQ10, RXYCQ12
28.6 Brazing connection: RXYCQ14
3D080763
79
(knock-out hole)
Model.
RXYCQ16
RXYCQ18
RXYCQ20
(knock-out hole)
No.
1
2
3
4
5
6
7
8
9
10
AA
83
83
63
AB
179
179
160
(knock-out hole)
Parts name
Liquid pipe connection port
Gas pipe connection port
Grounding terminal
Power cord routing hole (side)
Power cord routing hole (front)
Power cord routing hole (front)
Power cord routing hole (bottom)
Wire routing hole (front)
Pipe routing hole (front)
Pipe routing hole (bottom)
Remarks
See note 2
See note 2
Inside of switch box (M8)
62
45
27
65.5
27
NOTES
1. Detail for front side and detail for bottom side indicate the dimensions after fixing the
attached piping.
2. Gas pipe:
28.6 Brazing connection: RXYCQ16,18,20
Liquid pipe:
12.7 Brazing connection: RXYCQ20
9.5 Brazing connection: RXYCQ16,18
3D080767
RXYCQ-A
RXYCQ-A
For single unit installation
< Pattern 1 >
300 or more
10 or more
< Pattern 2 >
50 or more
300 or more
10 or more 10 or more
20 or more
50 or more 50 or more
300 or more
300 or more
20 or more
10 or more
300 or more
10 or more
20 or more
10 or more
10 or more
10 or more
20 or more
10 or more
20 or more
< Front >
10 or more
100 or more
100 or more
100 or more
300 or more
10 or more
20 or more
10 or more
50 or more
< Pattern 2 >
100 or more
100 or more
300 or more
400 or more
200 or more
400 or more
50 or more
100 or more
50 or more
50 or more
50 or more
100 or more
50 or more
50 or more
100 or more
100 or more
< Front >
50 or more
100 or more
50 or more
80
h1
500 mm
1500 mm
NOTES
h2
3D051451U
Replacement VRV
Indoor units
VRV type indoor units
22
Ventilation
Heat Reclaim ventilation (VAM/VKM)
AHU connection kit
Control systems
VRV III
VRV IV
Heat pump
VRV configurator
DC fan motor
I demand function
For more information on these features refer to the VRV IV technologies tab
81
Replacement
technology
The quick and quality way of
upgrading R-22 and R-407C systems
The phase-out period for R-22 is over. Act now!
R-22 ban in Europe
82
R-407C (RSXYP-L7)
R-410A (RXYQQ-T)
Conventional solution
VRV-Q
1
2
3
4
5
6
7
1 Recover refrigerant
2 Remove units
Recover refrigerant
Remove units
Remove refrigerant pipes
Install new piping and wiring
Install new units
Leak test
Vacuum drying
8 Refrigerant charging
9 Collect contamination
10 Test operation
Up to 45% shorter
installation time
Easy as one-two-three
A simple solution for replacement technology enables you
to handle more projects for more customers in less time and
offer them the best price! Everybody gains.
One touch
convenience:
Measure and charge
refrigerant
Automatic pipe
cleaning
Test operation
83
Replacement VRV
Quick & quality replacement for R-22 and R-407C systems
Cost-effective and fast replacement through re-use of exisiting
piping
replacement
Outdoor system
System
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
RQCEQ
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Outdoor unit module 4
Nom.
Nom.
Cooling
Heating
HP
kW
kW
kW
kW
Nom.
Nom.
EER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Sound pressure level
Cooling
Nom.
Piping connections
Liquid
OD
Gas
OD
Discharge gas
OD
Total piping length
System
Current - 50Hz
Maximum fuse amps (MFA)
Actual
84
dBA
mm
mm
mm
m
A
RQEQ
mm
kg
m/min
dBA
dBA
CDB
CWB
kg/TCO2Eq
Hz/V
A
RQCEQ712-848P
280P
360P
460P
500P
540P
636P
712P
744P
816P
848P
RQEQ140P RQEQ180P
RQEQ140P
RQEQ180P RQEQ212P
RQEQ140P
RQEQ180P RQEQ212P
RQEQ140P RQEQ180P RQEQ140P
RQEQ180P
RQEQ212P
RQEQ180P
RQEQ212P
RQEQ212P RQEQ180P
RQEQ212P
RQEQ180P
RQEQ212P
10
13
16
18
20
22
24
26
28
30
28.0
36.0
45.0
50.0
54.0
63.6
71.2
74.4
81.6
84.8
32.0
40.0
52.0
56.0
60.0
67.2
78.4
80.8
87.2
89.6
7.04
10.3
12.2
13.9
15.5
21.9
21.2
23.3
27.1
29.2
8.00
10.7
13.4
14.7
16.1
17.7
20.7
21.2
23.1
23.6
3.98
3.48
3.77
3.61
3.48
2.90
3.36
3.19
3.01
2.90
4.00
3.72
3.89
3.80
3.72
3.79
3.80
3.81
3.77
3.79
21
28
34
39
43
47
52
56
60
64
140
180
230
250
270
318
356
372
408
424
280
360
500
540
636
712
744
816
848
364
468
598
650
702
827
926
967.0
1,061
1,102
57
61
62
63
64
63
64
65
66
9.52
12.7
15.9
19.1
22.2
25.4
28.6
34.9
19.1
22.2
25.4
28.6
300
30
40
50
60
70
80
90
140P
180P
1,680x635x765
212P
175
179
95
54
10.3/21.5
15
110
58
-5~43
-20~15.5
R-410A / 2,087.5
10.6/22.1
3~/50/380-415
20
60
11.2/23.4
22.5
Replacement VRV
RXYQQ8-12T
Outdoor system
System
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
RXYQQ RQYQ140P
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
22T
24T
RXYQQ10T RXYQQ8T
RXYQQ12T RXYQQ16T
HP
5
8
10
12
14
16
18
20
22
24
kW
14.0
22.4
28.0
33.5
40.0
45.0
50.4
56.0
61.5
67.4
kW
16.0
25.0
31.5
37.5
45.0
50.0
50.4
63.0
69.0
75.0
kW
3.36
5.21
7.29
8.98
11.0
13.0
15.0
18.5
16.27
18.21
kW
3.91
5.51
7.38
9.10
11.2
12.8
12.6
17.0
16.48
18.31
4.17
4.30
3.84
3.73
3.64
3.46
3.36
3.03
3.78
3.70
6.37 (1) / 7.53 (2) 5.67 (1) / 7.20 (2) 5.50 (1) / 6.96 (2) 5.31 (1) / 6.83 (2) 5.05 (1) / 6.50 (2) 4.00 (1) / 3.87 (2) 4.42 (1) / 5.67 (2) 5.58 (1) / 7.07 (2) 5.42 (1) / 6.81 (2)
4.09
4.54
4.27
4.12
4.02
3.91
4.97
3.71
4.19
4.10
10
64 (3)
64 (3)
62.5
100
125
150
175
200
225
250
275
300
125
200
250
300
350
400
450
500
550
600
162.5
260
325
390
455
520
585
650
715
780
1,685x930x765
1,685x1,240x765
mm 1,680x635x765
kg
175
187
194
305
314
m/min
95
162
175
185
223
260
251
261
dBA
78
79
81
86
88
dBA
54.0
58
61
64
65
66
dBA
56
58
58
58
58
60
60
dBA
55
54
54
52
52
52
52
dBA
53
52
52
47
47
48
48
CDB
-5~43
CWB
-20~15.5
R-410A / 2,087.5
kg/TCO2Eq 11.1/23.2 5.9/12.3
6/12.5
6.3/13.2 10.3/21.5 10.4/21.7 11.7/24.4 11.8/24.6
mm
9.52
9.52
12.7
15.9
mm
15.9
19.1
22.2
28.6
34.9
m
300
300
Hz/V
3N~/50/380-415
A
15
20
25
32
40
50
63
Nom.
Nom.
RXYQQ
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Nom.
Nom.
Cooling
Heating
HP
kW
kW
kW
kW
Nom.
Nom.
EER
ESEER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Sound power level
Cooling
Nom.
Sound pressure level
Cooling
Nom.
Piping connections
Liquid
OD
Gas
OD
Total piping length
System
Current - 50Hz
Maximum fuse amps (MFA)
10T
12T
14T
16T
18T
20T
EER
ESEER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Fan
Air flow rate
Cooling
Nom.
Sound power level
Cooling
Nom.
Sound pressure level
Cooling
Cooling
Night
Level 1
Quiet
Level 2
Mode
Level 3
Operation range
Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type / GWP
Charge
Piping connections
Liquid
OD
Gas
OD
Total piping length
System
Actual
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
Outdoor system
System
8T
Actual
dBA
dBA
mm
mm
m
A
26T
28T
30T
32T
34T
RXYQQ12T
RXYQQ16T
RXYQQ14T RXYQQ16T RXYQQ18T RXYQQ16T RXYQQ18T
26
28
30
32
34
73.5
78.5
83.5
90.0
95.0
82.5
87.5
93.5
100.0
106.0
19.98
21.98
23.68
26.0
27.7
20.30
21.90
23.50
25.6
27.2
3.68
3.57
3.53
3.5
3.4
5.39 (1) / 6.89 (2) 5.23 (1) / 6.69 (2) 5.17 (1) / 6.60 (2) 5.05 (1) / 6.50 (2) 5.01 (1) / 6.44 (2)
4.06
4.00
3.98
3.9
64 (3)
325
350
375
400
425
650
700
750
800
850
845
910
975
1,040
1,105
19.1
34.9
300
63
80
36T
RXYQQ20T
36
101.0
113.0
31.5
29.8
3.2
4.68 (1) / 6.02 (2)
3.8
450
900
1,170
38T
40T
42T
RXYQQ8T
RXYQQ10T
RXYQQ10T RXYQQ12T RXYQQ16T
RXYQQ20T RXYQQ18T RXYQQ16T
38
40
42
106.4
111.5
118.0
119.5
125.0
131.5
31.00
30.97
33.29
29.89
30.88
32.98
3.43
3.60
3.54
5.03 (1) / 6.36 (2) 5.29 (1) / 6.74 (2) 5.19 (1) / 6.65 (2)
4.00
4.05
3.99
475
950
1,235
500
1,000
1,300
525
1,050
1,365
41.3
100
(1) The STANDARD ESEER value corresponds with normal VRV4 Heat Pump operation, not taking into account advanced energy saving operation functionality (2) The AUTOMATIC SEER value corresponds with normal VRV4 Heat Pump operation, taking into
account advanced energy saving operation functionality ( variable refrigerant temperature control operation) (3) Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, RA indoor, etc.) and the connection ratio
restriction for the system (50% <= CR <= 130%)
85
Oblong holes
Outdoor unit 1
Outdoor unit 2
or more
(Front)
or more
Unit:mm
Model name
RQCEQ280P
RQCEQ360P
or more
or more
or more
or more
Outdoor unit 1
RQEQ140P
RQEQ180P
Drawing N.
3D066441
3D066441
Outdoor Unit 2
RQEQ140P
RQEQ180P
Drawing N.
3D066441
3D066441
NOTES
1. Heights of walls
Front: 1500mm
Suction side: 500mm
Side: Height unrestricted
The installation space shown in this figure is based on the condition of cooling operation at the outdoor air temperature of 35C.
The installation space of suction side shown above must be expanded in the following case.
- Design outdoor temperature becomes over 35C.
- Operating over Max. operating load
(In case of causing a heavy heating load at indoor unit side)
2. If the above wall heights are exceeded then h2/2 and h1/2 should be added to the front and suction side service spaces respectively as shown in the following figure.
3. When installing the units the most appropriate pattern should be selected from those shown above in order to obtain the best fit in the space available always bearing in mind the need to leave
enough room for a parson to pass between nuits and wall for the air to circulate freely. (If more units are to be installed than are catered for in the above patterns your layout should take account of the possibility of short circuits.)
4. The units should be installed to leave sufficient space at the front for the on site refrigerant piping work to be carried out comfortably.
3D066856
86
Oblong holes
Oblong holes
(Foundation bolt hole)
Outdoor Unit 2
Outdoor Unit 3
Outdoor Unit 1
or more
or more
or more
or more
or more
or more
or more
or more
Unit:mm
Model name
RQCEQ460P
RQCEQ500P
RQCEQ540P
RQCEQ636P
Outdoor unit 1
RQEQ180P
RQEQ180P
RQEQ180P
RQEQ212P
Drawing N.
3D066441
3D066441
3D066441
3D066441
Outdoor Unit 2
RQEQ140P
RQEQ180P
RQEQ180P
RQEQ212P
Drawing N.
3D066441
3D066441
3D066441
3D066441
Outdoor unit 1
RQEQ140P
RQEQ140P
RQEQ180P
RQEQ212P
Drawing N.
3D066441
3D066441
3D066441
3D066441
NOTES
1. Heights of walls
Front: 1500mm
Suction side: 500mm
Side: Height unrestricted
The installation space shown in this figure is based on the condition of cooling operation at the outdoor air temperature of 35C.
The installation space of suction side shown above must be expanded in the following case.
- Design outdoor temperature becomes over 35C.
- Operating over Max. operating load
(In case of causing a heavy heating load at indoor unit side)
2. If the above wall heights are exceeded then h2/2 and h1/2 should be added to the front and suction side service spaces respectively as shown in the following figure.
3. When installing the units the most appropriate pattern should be selected from those shown above in order to obtain the best fit in the space available always bearing in mind the need to leave
enough room for a parson to pass between nuits and wall for the air to circulate freely. (If more units are to be installed than are catered for in the above patterns your layout should take account of the possibility of short circuits.)
4. The units should be installed to leave sufficient space at the front for the on site refrigerant piping work to be carried out comfortably.
3D066860
87
Outdoor Unit 1
Outdoor Unit 2
Outdoor Unit 3
Outdoor Unit 4
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
Unit: mm
Model name
RQCEQ712P
RQCEQ744P
RQCEQ816P
RQCEQ848P
Outdoor unit 1
RQEQ212P
RQEQ212P
RQEQ212P
RQEQ212P
Drawing N.
3D066441
3D066441
3D066441
3D066441
Outdoor Unit 2
RQEQ180P
RQEQ212P
RQEQ212P
RQEQ212P
Drawing N.
3D066441
3D066441
3D066441
3D066441
Outdoor unit 3
RQEQ180P
RQEQ180P
RQEQ212P
RQEQ212P
Drawing N.
3D066441
3D066441
3D066441
3D066441
Outdoor unit 4
RQEQ140P
RQEQ140P
RQEQ180P
RQEQ212P
Drawing N.
3D066441
3D066441
3D066441
3D066441
NOTES
1. Heights of walls
Front: 1500mm
Suction side: 500mm
Side: Height unrestricted
The installation space shown in this figure is based on the condition of cooling operation at the outdoor air temperature of 35C.
The installation space of suction side shown above must be expanded in the following case.
- Design outdoor temperature becomes over 35C.
- Operating over Max. operating load
(In case of causing a heavy heating load at indoor unit side)
2. If the above wall heights are exceeded then h2/2 and h1/2 should be added to the front and suction side service spaces respectively as shown in the following figure.
3. When installing the units the most appropriate pattern should be selected from those shown above in order to obtain the best fit in the space available always bearing in mind the need to leave
enough room for a parson to pass between nuits and wall for the air to circulate freely. (If more units are to be installed than are catered for in the above patterns your layout should take account of the possibility of short circuits.)
4. The units should be installed to leave sufficient space at the front for the on site refrigerant piping work to be carried out comfortably.
3D066865
88
RQYQ140P
(knock-out hole)
(knock-out hole)
(knock-out hole)
(knock-out hole)
(knock-out hole)
No.
1
2
3
4
5
6
7
8
9
10
Parts name
Liquid pipe connection port
Gas pipe connection port
Grounding terminal
Power cord routing hole (side)
Power cord routing hole (front)
Power cord routing hole (front)
Power cord routing hole (bottom)
Wire routing hole (front)
Pipe routing hole (front)
Pipe routing hole (bottom)
Remarks
9.5 Brazing connection
See note 3.
Inside of switch box (M8)
62
45
27
50
27
See note 2.
See note 2.
3D066442
NOTES
For piping connection method (front and bottom sides) see the installation manual.
Gas pipe
15.9 Brazing connection: RQYQ140P
89
Detail A
70
106
AC
125
107
66
160
353
134
112
729
100
AA
AB
339
Detail B
10
4-15x22.5mmOblong hole
Foundation bolt hole
View C
1685
11
122
179
131
276
259
515
Model
RYYQ8T, RXYQ8T, RXYQQ8T
RYYQ10-12T, RXYQ10-12T, RXYQQ10-12T
RYMQ8T
REMQ5T, RYMQ10-12T, REYQ8-12T
76
76
97
137
DETAIL B
DETAIL A
765
Notes
373
930
11
10
9
8
7
6
5
4
AB
205
210
65
27
65
80
65
2
1
No.
Grounding terminal
AA
240
240
328
Equalising pipe
RYMQ8-10T :
RYMQ12T :
AC
240
240
107
Liquid pipe
RYYQ8-10T, RYMQ8-10T, RXYQ8-10T, RXYQ
Q8-10T, REMQ5T, REYQ8-12T
:
RYYQ12T, RYMQ12T, RXYQ12T, RXYQQ12T :
AB
208
208
272
1. Detail A and detail B indicate the dimensions after fixing the attached piping.
2. Items 4 - 10:
Knockout hole.
3. Gas pipe
RYYQ8T, RYMQ8T, RXYQ8T, RXYQQ8T
:
RYYQ10T, RYMQ10T, RXYQ10T, RXYQQ10T :
REMQ5T, REYQ8-12T
:
RYYQ12T, RYMQ12T, RXYQ12T, RXYQQ12T :
AA
248
195
248
195
See note 3.
See note 3.
See note 3.
Part name
Remark
2D079532B
RXYQQ14-20T
RYYQ14-20T
RYMQ14-20T
RXYQ14-20T
RXYQQ14-20T
106
160
393
134
107
112
125
70
71
100
AB
192
310
729
10
AA
Detail B
Detail A
View C
1685
11
122
179
97
137
DETAIL B
765
Notes
DETAIL A
107
272
328
373
1. Detail A and detail B indicate the dimensions after fixing the attached piping.
2. Items 4 - 10:
Knockout hole.
:
90
131
76
76
3. Gas pipe
REYQ14-20T
259
276
515
Model
RYMQ14-16T, RXYQQ14-16T, REYQ14-20T
RYMQ18-20T, RXYQQ18-20T
1240
25.4 brazing connection
Liquid pipe
RYYQ14-16T, RYMQ14-16T, RXYQ14-16T, RXYQQ14-16T, REYQ14-20T :
Equalising pipe
RYMQ14-16T
RYMQ18-20T
11
10
9
8
7
6
5
4
3
Grounding terminal
65
27
65
80
65
See note 3.
See note 3.
See note 3.
Remark
2D079533B
(PATTERN 1)
(PATTERN 1)
300
or more
(PATTERN 1)
300 or more
300 or more
(Front)
10 or more
(Front)
10 or more
10 or more
500
or more
10 or more
20 or more
500 or more
20 or more
(PATTERN 1)
300 or more
(Front)
500
or more
20 or more
900
or more
20 or more
500
or more
(Front)
20 or more
10 or more
20 or more
(PATTERN 1)
10 or more
10 or more
20 or more
500
or more
600 or more
10 or more
(PATTERN 2)
(PATTERN 2)
100 or more
(Front)
100 or more
20 or more
500 or more
10 or more
10 or more
(Front)
(Front)
300
or more
10 or more
10 or more
20 or more
10 or more
10 or more
10 or more
(Front)
10 or more
(Front)
50 or more
100 or more
100 or more
500
or more
100 or more
(PATTERN 2)
50 or more
(PATTERN 2)
100 or more
(PATTERN 2)
100 or more
(Front)
500 or more
(Front)
(PATTERN 3)
(PATTERN 3)
100 or more
50 or more
Wall height
unrestricted
50 or more
100 or more
50 or more
50 or more
500 or more
500 or more
100 or more
50 or more
(Front)
(Front)
RYYQ-T (Front)
RYMQ-T 200 or more
RXYQ-T
(Unit : mm)
RXYQQ-T
400 or more
100 or more
50 or more
100 or more
100 or more
50 or more
500 or more
50 or more
3D066327
(FRONT)
more
more
20 or more
20 or more
(FRONT)
10 or more 10 or more
20 or more
(FRONT)
10 or more
(FRONT)
20 or more
10 or more 10 or more
20 or more
500 or more
When installing
the units the most appropriate pattern
in order to obtain the best
t in the500space
500 orshould
more be selected from those shown above
10 or more
or more available always
600 or more
bearing in mind the need to leave enough room for a person to pass between units and wall and for the air to circulate freely. (If more units are to be installed
RYYQ-T
(Pattern
2)
(Pattern
2) your layouts should take account of the possibility of short circuits.)
than
are catered
for in the above
patterns
RYMQ-T
100 or more
100 or more
10 or more
morecarried10 out
or more
The units should be installed to leave sufcient space
at the front for the on site refrigerant
piping
toorbe
comfortably. 300 or more
(FRONT)work 20
RXYQ-T
500 or more
10 or more
RXYQQ-T
(Pattern 2)
50 or
more 50 or more
(FRONT)
500 or more
(Pattern 3)
(Pattern 1)
RXYQQ-T
(Pattern 2)
10 or
more
10 or
more
(FRONT)
500 or more
(Pattern 1)
20 or more
(Pattern 2)
(Pattern 3)
Wall height
unrestricted
300 or more
10 or
(FRONT)(Patternmore
3)
500 or more
20 or more
50 or more
NOTES
100 or more
(FRONT)
50 or more
(FRONT)
500 or more
100 or more
more 50 or more
(Pattern 3)
300 or more
(FRONT)
400 or more
100 or more
(FRONT)
500 or more
(Pattern 3)
Wall height
unrestricted
50 or more
100 or more
20 or more
100 or
more
50 or more
50 or more
10 or more
10 or more
20 or more
(Pattern 1)
10 or more
10 or more
(FRONT)
500 or more
(FRONT)
600 or more
100 or more
100 or more
(FRONT)
500 or more
300 or more
300 or more 100 or more
(FRONT)
500 or more
50 or more
50 or more
100 or more
50 or more 50 or more
20 or more
100(FRONT)
or more
500 or more
10 or more
20 or more
10 or more
10 or more
20 or more
(FRONT)
(FRONT)
100 or
more
(FRONT)
100 or
300 or more
10 or more
20 or more
10 or more
(FRONT)
more
10 or more
20 or more
500 or more
10 or 300
moreor more
20 or more
10 or more
(FRONT)
(FRONT)
50 or more
100 or more
500 or(Pattern
more 2)
100 or more
50 or more
50 or more 50 or more
100 or more
50 or more
50 or more
(FRONT)
500 or more
100 or more
100 or
more
50 or
more 50 or more
500
or more
(FRONT)
500 or more
50 or more
10 or more
900 or more
10 or more
(FRONT)
20 or more
10 or more 10 or more
20 or more
50 or
10 or more
500 or more
more 50 or more
50 or more
100 or more
(FRONT)
50 or more
500 or more
100 or more
100 or
more
50 or more
600 or more
20 or more
300 or more
20 or more
500 or more
<Unit = mm>
10 or more 10 or more
300 or more
300 or more
100 or
20 or more more 10 or more 10 or more
400 or more
50 oror more
200
(FRONT)
600 or more
50 or more
100 or more
(FRONT)
100 or more
or more
500300
or more
(Pattern 2)
300 or more
(FRONT)
500 or more
10 or
more
(Pattern 2)
(FRONT)
200 or more
10 or more
(Pattern 1)
50 or
300 or more
more 50 or more
100 or more
10 or more
10 or more 10 or more
100 or more
(Pattern 1)
(FRONT)
500 or more
20 or more
100 or more
50 or more
50 or more
400 or more
(FRONT)
500 or more
20 or more
(FRONT)
(FRONT)
50 or
group
50 or moreFor centralized
more 50 or more
100
or more layout
(FRONT)
500 or more
(Pattern 1)
300 or more (FRONT)
400 or more
200 or more
10 or more
100 or
more
100 or
more
300 or more
RYYQ-T
10 or more
10 or more
50 or more
unrestricted
300RYMQ-T
or more
(FRONT)
200 orRXYQ-T
more
10 or more
100 or more
(FRONT)
500 or more
(Pattern 3)
100 or more
20 or more
500 or more
900 or more
<Front>
50 or more
RXYQQ-T
50 or more
(Unit : mm)
If the above wall heights are exceeded then h2/2 and h1/2 should be added to the front and suction side service spaces respectively as shown in the gure on
10 or
10 or
the right.
(FRONT)
100 or more
50 or more
NOTES
Heights
1 and
Height
unrestricted. Installation space to be shown in this drawing
(Patternof1)walls in case of patterns
(Pattern
1) 2: Front: 1500mm. Suction side: 500 mm. Side:
(Pattern
1)
is based on the cooling operation at 35 degrees outdoor air temperature. When the design outdoor air temperatur exceeds 35 degrees or the load exceeds
300
or
more
or moreheat in all outdoor unit, take the suction side
maximum ability because of much generation300load
space
beor shown
in this drawing.
300 or
more more broadly than the space to300
more
10 or more
(Front)
500
or more
(Front)
50 or more
400 or more
(Front)
(Unit : mm)
400 or more
200 or more
50 or more
600 or more
(Suction side)
300 or more
(Front)
(Front)
50 or more
500
or more
(FRONT)
500 or more
10 or more
500 or more
500 or more
<Suction side>
50 or more
10 or more
900 or more
50 or more
600 or more
500 or more
10 or more
(FRONT)
500 or more
50 or more
500 or more
<Unit = mm>
(FRONT)
500 or more
100 or more
50 or more
50 or more
100 or more
600 or more
50 or more
NOTES
<Suction side>
<Suction side>
<Front>
<Front>
100 or
1. Heights of walls in case of patterns 1 and 2:
more
300 or more
Front: 1500mm
50 or more
(FRONT)
50 or more
100 or more
400
or
more
400 or more
(FRONT)
(FRONT)
500 or more
100 or more
50 or more
50 or more 50 or more
50 or more
(FRONT)
100 or more
Suction side: 500mm
200 or more
200 or more
500 or more
Side: Height unrestricted
<Unit = mm>
Installation space as shown on this drawing is based on the cooling operation at 35 degrees outdoor air temperature.
When the design outdoor air temperature exceeds 35 degrees or the load exceeds maximum ability of much generation load of heat in all outdoor unit, take the suction side space more
broadly than the space as shown on this drawing.
2. If the above wall heights are exceeded then h2/2 and h1/2 should be added to the front and suction side service spaces respectively as shown in the figure on the right.
3. When installing the units most appropriate pattern should be selected from those shown above in order to obtain the best fit in the
space available. Always keep in mind the need to leave enough space for a person to pass between units and wall and also for the air to circulate freely.
(If more units are to be installed than are catered for in the above patterns your layout should take account of the possibility of short circuits).
4. The units should be installed to leave sufficient space at the front for the on site refrigerant piping work to be carried out comfortably.
91
Water cooled
VRV IV W-series
Ideal for high rise buildings,
using water as heat source
Air curtain
Biddle Air curtain for VRV (CYV)
22
Indoor units
VRV type indoor units
Hot water
Low temperature hydrobox
Control systems
Ventilation
Heat Reclaim ventilation (VAM/VKM)
AHU connection kit
VRV IV standards:
Variable refrigerant temperature
Customize your VRV for best seasonal efficiency & comfort
Full inverter compressors
Reluctance brushless DC compressor
Sine wave DC inverter
Manual demand function
Geothermal operation
For more information on these features refer to the VRV IV technologies tab
92
Geothermal operation
and advantages
Geothermal operation uses the more stable
temperature of the ground around the building,
eliminating the need for another heat source. It
reduces CO2 emissions and is an infinitely renewable
energy source.
Outside
temperature
Wind
-10C
45C
Heating
6C
45C
* Ethylene glycol should be added to the water when the water inlet
temperature is below 5C
Cooling
93
stage 2
stage 1
VRV-W
VRV-W
VRV-W
Indoor units
Heat absorbed from loop
mainly heating,
partly cooling
VRV-W
94
Ceiling height
3,200mm
or higher
Floor level
* for 8HP unit
100-300mm
Variable water
Flow Control Valve
Inverter Pump
35
30
Pressure drop (lkPa)
40
new filter
25
20
15
10
old filter
5
0
50
70
90
110
130
150
95
300m
120m (140m)
40m (90m1)
50m (40m)
15m
Actual piping length between the VRV-W and indoor units: 120m (Equivalent piping length: 140m)
Level difference
between the VRV-W
and indoor units:
50m if the VRV-W is above
40m if the VRV-W is below
VRV-W
Water piping
Indoor installation
Refrigerant piping
VRV-WIII geothermal system, Daikin Altherma HT, Sky Air, aircooled chiller with heat recovery, iManager,
iTouch Manager, ACNSS
96
PARK PHI
BREAAM EXCELLENT OFFICE
BUILDING
WATERCOOLED VRV
97
RWEYQ-T
RWEYQ8-10T
Standard operation
Outdoor unit
System
Capacity range
Cooling capacity
Heating capacity
Power input - 50Hz
RWEYQ
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Nom.
Nom.
Cooling
Heating
Nom.
Nom.
8T
RWEYQ8T
10T
RWEYQ10T
-
HP
kW
kW
kW
kW
8
22.4
25.0
4.42
4.21
5.07
5.94
10
28.0
31.5
6.14
6.00
4.56
5.25
EER
COP
Maximum number of connectable indoor units
Indoor index
Min.
100
125
connection
Nom.
200
250
Max.
260
325
Dimensions
Unit
HeightxWidthxDepth
mm
1,000x780x550
Weight
Unit
kg
137
Fan
Air flow rate
Cooling
Nom.
m/min
Sound power level
Cooling
Nom.
dBA
Sound pressure level
Cooling
Nom.
dBA
50
51
Min.~Max.
CDB
Operation range
Inlet water
Cooling
temperature
Min.~Max.
CWB
Heating
Refrigerant
Type / GWP
3.5/7.3
4.2/8.8
Charge
kg/TCO2Eq
Piping connections
Liquid
OD
mm
9.52
Gas
OD
mm 19.10 (1)
22.2 (1)
Discharge gas
OD
mm 15.9 (2) / 19.10 (3) 19.1 (2) / 22.10 (3)
Water
Inlet/Outlet
Total piping length
System
Actual
m
Power supply
Phase/Frequency/Voltage
Hz/V
Current - 50Hz
Maximum fuse amps (MFA)
A
20
(1) In case of heat pump system, gas pipe is not used (2) In case of heat recovery system (3) In case of heat pump system
98
Geothermal operation
16T
18T
20T
RWEYQ8T
RWEYQ10T
RWEYQ8T
RWEYQ10T
16
18
20
44.8
50.4
56.0
50.0
56.5
63.0
8.8
10.6
12.3
8.4
10.2
12.0
5.07
4.77
4.56
5.94
5.53
5.25
36
200
225
250
400
450
500
520
585
650
24T
26T
RWEYQ8T
RWEYQ8T
RWEYQ8T
24
26
67.2
72.8
75.0
81.5
13.3
15.0
12.6
14.4
5.07
4.86
5.94
5.65
300
600
780
-
325
650
845
28T
30T
RWEYQ10T
RWEYQ10T
RWEYQ10T
28
30
78.4
84.0
88.0
94.5
16.7
18.4
16.2
18.0
4.69
4.56
5.43
5.25
350
700
910
375
750
975
53
12.7
54
10~45
-10 / 10.0~45
R-410A / 2,087.5
15.9
55
56
19.1
28.6 (1)
34.9 (1)
22.2 (2) / 28.60 (3)
28.6 (2) / 34.90 (3)
PT1 1/4B internal thread/PT1 1/4B internal thread
300
3N~/50/380-415
32
50
Bottom View
8x 17
(Foundation Bolt Hole)
(After attaching
accessories pipe)
Front View
Rear View
Manufacturers
label
Item
Part Name
Remark
3D085178
NOTES
Liquid Pipe
See note 2
See note 2
See note 2
Water Inlet
Water Outlet
Drain Outlet
Earth Terminal
M5
29
29
10
11
Grounding terminal
MODEL NAME
Operation System
Liquid Pipe
Suction Gas Pipe
HP/LP Gas Pipe
Heat Pump
9.5
19.1
RWEYQ8
Heat Recovery
9.5
19.1
15.9
Heat Pump
9.5
22.2
RWEYQ10
Heat Recovery
9.5
22.2
19.1
Service space
(rear)
For installation
in a row
Secure 300mm or more of service space
even not using for rear side take-out
Service space
(rear)
Service space
(rear)
Outside unit
Outside unit
500 or more
500 or more
RWEYQ-T
RWEYQ-T
390 or more
Outside unit
Water piping
installation space
Secure enough
space for removing
front plate
350 or less
20 or more
Space for
installation in
a row
Front view
20 or more
Space for
installation in
a row
350 or more
20 or more
Space for
installation in
a row
Service space
(front)
300 or more
Service space
(front)
900 or more
H: free
W: 179 mm
250 or less
Service space
(front)
20 or more
Space for
installation in
a row
900 or more
20 or more
Space for
installation in
a row
100 or more
Water piping installation space
3D048341F
99
RWEYQ-T
100
NEW
101
Indoor Units
VRV Indoor
102
Indoor Units
VRV Indoor
103
Benefits overview
We care icons
VRV indoor
Inverter technology
Fan only
The air conditioner can be used as fan, blowing air without cooling or heating
Air treatment
Whisper quiet
When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and the fan to
low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired
Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed not to disturb the quiet of the
neightbourhood
Air filter
Humidity
control
Comfort
Draught prevention
The filter automatically cleans itself once a day. Simplicity of upkeep means optimum energy efficiency and maximum
comfort without the need for expensive or time-consuming maintenance
The presence sensor directs the air away from any person detected in the room. The floor sensor detects the average
floor temperature and ensures an even temperature distribution between ceiling and floor
Dry programme
Other funtions
Air flow
104
The air discharge of the indoor unit is specially designed to prevent air being blown against the ceiling to prevent
ceiling stains
Possibility to select automatic vertical moving of the air discharge louvre, for uniform air flow and temperature
distribution
Individual flap control via the wired remote controller makes it simple to fix the position of each flap individually,
to suit any new room configuration. Optional closure kits are available as well
Weekly timer
Timer can be set to start and stop operation anytime on a daily or weekly basis
Infrared remote control with LCD to remotely control your indoor unit
Centralised control
Centralised control to to control several indoor units from one single point
Auto-restart
The unit restarts automatically at the original settings after power failure
Self-diagnosis
Multi tenant
The indoor units main power supply can be turned off when leaving the building or for servicing purposes
Wall
mounted
unit
FXFQ-A
FXZQ-A
FXCQ-A
FXKQ-MA
FXDQ-M9
FXDQ-A
FXSQ-A
FXMQ-P7
FXMQ-MA9
FXAQ-P
FXHQ-A
FXUQ-A
FXNQ-A
FXLQ-P
G1
F8 (optional)
G1
Indoor Units
G1
G1
F8 (optional)
G1
F8 (optional)
G1
G1
G1
G1
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Optional
Optional
Optional
Standard
( )
( )
( )
( )
( )
105
Check on
FXFQ-A
https://www.youtube.com/
DaikinEurope
References
Wolverhampton, UK
Running costs were reduced by up to 50% compared
with standard solutions thanks to daily filter cleaning.
7000
6000
5000
4000
presence
sensor
Flexible installation
Flaps can be individually controlled or closed
using the wired remote control, to suit room
configuration.
Optional closure kits are also available.
* available as an option
106
50% difference
in electricity
consumption
3000
2000
1000
0
July Aug. Sept. Oct. Nov. Dec. Jan. Feb. March April May June July
Standard round
flow cassette
8000
floor sensor
Designed for use in all types and sizes of commercial offices and
retail environments.
Perfect environment conditions: no more draughts or cold feet.
Save up to 50% on running costs with the auto-cleaning panel,
which also facilitates maintenance.
Your customers can save up to 27% on their energy bills thanks
to the sensor option.
Flexible use of space thanks to individual flap control.
FXFQ-A
and comfort
FXFQ20-63A
20-63
BRC1E52A/B
BRC7FA532F
presence sensor
floor sensor
/////////////////////////
Indoor Units
///////////////////
Main unit
Branch discharge
Main discharge
installation speed
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Weight
Casing
Decoration panel
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
Unit
Material
Model
Colour
Dimensions
HeightxWidthxDepth
Weight
Decoration panel 2
Model
Colour
Dimensions
HeightxWidthxDepth
Weight
Decoration panel 3
Model
Colour
Dimensions
HeightxWidthxDepth
Weight
Fan-Air flow rate Cooling
High/Nom./Low
50Hz
Heating
High/Nom./Low
Air filter
Type
Sound power level
Cooling
High/Nom.
Sound pressure level Cooling
High/Nom./Low
Heating
High/Nom./Low
Refrigerant
Type / GWP
Piping connections
Liquid
OD
Gas
OD
Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
Control systems
Infrared remote control
Simplified wired remote control for hotel applications
Wired remote control
FXFQ
kW
kW
kW
kW
mm
mm
mm
kg
20A
2.2
2.5
25A
2.8
3.2
32A
3.6
4.0
0.038
0.038
mm
mm
Hz/V
A
63A
7.1
8.0
0.061
0.061
80A
9.0
10.0
0.092
0.092
100A
11.2
12.5
0.115
0.115
246
125A
14.0
16.0
0.186
0.186
288
840
840
19
20
mm
kg
dBA
dBA
dBA
50A
5.6
6.3
0.053
0.053
204
mm
kg
mm
kg
m/min
m/min
40A
4.5
5.0
12.5/10.6/8.8
12.5/10.6/8.8
49/31/29/28
31/29/28
6.35
12.7
21
24
26
Galvanised steel plate
BYCQ140D7W1
Pure White (RAL 9010)
60x950x950
5.4
BYCQ140D7W1W
Pure White (RAL 9010)
60x950x950
5.4
BYCQ140D7GW1
Pure White (RAL 9010)
145x950x950
10.3
13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9
13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9
Resin net with mold resistance
51/53/55/60/61/33/31/29
35/33/30
38/34/30
43/37/30
45/41/36
33/31/29
35/33/30
38/34/30
43/37/30
45/41/36
R-410A / 2.087,5
9.52
15.9
VP25 (O.D. 32 / I.D. 25)
1~/50/60/220-240/220
16
BRC7FA532F
BRC1D52 / BRC1E52A/B
BYCQ140D7W1 = pure white panel with grey louvers , BYCQ140D7W1W = pure white standard panel with white louvers, BYCQ140D7GW1 = Pure white auto cleaning panel
The BYCQ140D7W1W has white insulations. Be informed that formations of dirt on white insulation is visibly stronger & that it is consequently not advised to install the decoration panel in environments exposed to concentrations of dirt.
107
108
Indoor Units
109
FXZQ-A
Check on
https://www.youtube.com/
DaikinEurope
Unique design in the market that integrates fully flat into the ceiling
Unique design
110
Top efficiency
When the room is empty, the sensor option can
adjust the set temperature or switch off the unit
saving up to 27% energy.
Individual flap control: easily control one or more
flaps via the wired remote controller (BRC1E52)
when rearranging the room. When fully closing or
blocking the flaps, the option Sealing member of
air discharge outlet is needed.
FXZQ-A
comfort
FXZQ-A
BRC1E52A-B
presence sensor
floor sensor
///////////////////
Main unit
Branch discharge
Main discharge
installation speed
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Nom.
Nom.
Cooling
Heating
Unit
Weight
Casing
Decoration panel
Nom.
Nom.
Height
Width
Depth
Unit
Material
Model
Colour
Dimensions
HeightxWidthxDepth
Weight
Decoration panel 2
Model
Colour
Dimensions
HeightxWidthxDepth
Weight
Decoration panel 3
Model
Colour
Dimensions
HeightxWidthxDepth
Weight
Fan-Air flow rate Cooling
High/Nom./Low
50Hz
Heating
High/Nom./Low
Air filter
Type
Sound power level
Cooling
High/Nom.
Sound pressure level Cooling
High/Nom./Low
Heating
High/Nom./Low
Refrigerant
Type / GWP
Piping connections
Liquid
OD
Gas
OD
Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
Control systems
Infrared remote control
Simplified wired remote control for hotel applications
Wired remote control
FXZQ
kW
kW
kW
kW
mm
mm
mm
kg
mm
kg
mm
kg
mm
kg
m/min
m/min
dBA
dBA
dBA
mm
mm
Hz/V
A
15A
1.7
1.9
20A
2.2
2.5
0.043
0.036
25A
2.8
3.2
32A
3.6
4.0
0.045
0.038
40A
4.5
5.0
0.059
0.053
50A
5.6
6.3
0.092
0.086
260
575
575
15.5
16.5
Galvanised steel plate
BYFQ60CW
White (N9.5)
46x620x620
2.8
BYFQ60CS
White (N9.5) + Silver
46x620x620
2.8
BYFQ60B3W1
White (RAL9010)
55x700x700
2.7
8.5/7/6.5
8.7/7.5/6.5
9/8/6.5
10/8.5/7
11.5/9.5/8
8.5/7/6.5
8.7/7.5/6.5
9/8/6.5
10/8.5/7
11.5/9.5/8
Resin net with mold resistance
49/50/51/54/31.5/28/25.5
32/29.5/25.5
33/30/25.5
33.5/30/26
37/32/28
31.5/28/25.5
32/29.5/25.5
33/30/25.5
33.5/30/26
37/32/28
R-410A / 2.087,5
6.35
12.7
VP20 (I.D. 20/O.D. 26)
1~/50/220-240
16
BRC7F530W (white panel) / BRC7EB530 (standard panel) / BRC7F530S (grey panel)
BRC1D52 / BRC1E52A/B
18.5
14.5/12.5/10
14.5/12.5/10
60/43/40/33
43/40/33
111
Indoor Units
BRC7F530W/S
112
FXCQ-A
more flaps can be easily closed via the wired remote control
FXCQ20-40A
BRC1E52A/B
BRC7C52
entirely when the unit is not operating and there are no air
intake grilles visible
Optimum comfort guaranteed with automatic air flow
adjustment to the required load
Maintenance operations can be performed by removing the
front panel
Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjecent rooms
/////////////////////////
installation speed
Indoor Units
Stylish unit blends easily with any interior. The flaps close
500 mm
///////////////////
Main unit
Branch discharge
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Weight
Casing
Decoration panel
Main discharge
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
FXCQ
kW
kW
kW
kW
mm
mm
mm
kg
Unit
Material
Model
Colour
Dimensions
HeightxWidthxDepth
mm
Weight
kg
Fan-Air flow rate - 50Hz
Cooling
High/Nom./Low
m/min
Air filter
Type
Sound power level
Cooling
Nom.
dBA
Sound pressure level Cooling
High/Nom./Low
dBA
Heating
High/Nom./Low
dBA
Refrigerant
Type / GWP
Piping connections
Liquid
OD
mm
Gas
OD
mm
Drain
Power supply
Phase/Frequency/Voltage
Hz/V
Current - 50Hz
Maximum fuse amps (MFA)
A
Control systems
Infrared remote control
Simplified wired remote control for hotel applications
Wired remote control
20A
2.2
2.5
0.031
0.028
25A
2.8
3.2
32A
3.6
4.0
0.039
0.035
40A
4.5
5.0
0.041
0.037
50A
5.6
6.3
0.059
0.056
63A
7.1
8.0
0.063
0.060
80A
9.0
10.0
0.090
0.086
125A
14.0
16.0
0.149
0.146
305
775
990
1,445
620
19
10.5/9/7.5
32.0/30.0/28.0
32.0/30.0/28.0
22
25
33
38
Galvanised steel plate
BYBCQ40HW1
BYBCQ63HW1
BYBCQ125HW1
Fresh white (6.5Y 9.5/0.5)
55x1,070x700
55x1,285x700
55x1,740x700
10
11
13
11.5/9.5/8
12/10.5/8.5
15/13/10.5
16/14/11.5 26/22.5/18.5 32/27.5/22.5
Resin net with mold resistance
34.0/31.0/29.0 34.0/32.0/30.0 36.0/33.0/31.0 37.0/35.0/31.0 39.0/37.0/32.0 42.0/38.0/33.0 46.0/42.0/38.0
34.0/31.0/29.0 34.0/32.0/30.0 36.0/33.0/31.0 37.0/35.0/31.0 39.0/37.0/32.0 42.0/38.0/33.0 46.0/42.0/38.0
R-410A / 2.087,5
6.35
9.52
12.7
15.9
VP25 (O.D. 32 / I.D. 25)
1~/50/220-240
16
BRC7C52
BRC1D52 / BRC1E52A/B
113
FXCQ50A
114
Indoor Units
FXCQ63A
FXCQ80-125A
115
FXKQ-MA
void (only 220mm ceiling space required, 195 with panel spacer,
available as accessory)
Optimum air flow conditions are created by either downward
air discharge or frontal air discharge (via optional grille) or a
combination of both
FXKQ-M
BRC1E52A/B
BRC4C61
500 mm
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Weight
Casing
Decoration panel
Power supply
Current - 50Hz
Control systems
116
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
FXKQ
kW
kW
kW
kW
mm
mm
mm
kg
Unit
Material
Model
Colour
Dimensions
HeightxWidthxDepth
mm
Weight
kg
Cooling
High/Low
m/min
Type
Cooling
Nom.
dBA
Cooling
High/Low
dBA
Type / GWP
Liquid
OD
mm
Gas
OD
mm
Drain
Phase/Frequency/Voltage
Hz/V
Maximum fuse amps (MFA)
A
Infrared remote control
Simplified wired remote control for hotel applications
Wired remote control
25MA
2.8
3.2
32MA
3.6
4.0
40MA
4.5
5.0
0.076
0.056
0.066
0.046
63MA
7.10
8.00
0.105
0.085
215
1,110
1,310
710
31
Galvanised steel plate
BYK45FJW1
White
70x1,240x800
8.5
11/9
38.0/33.0
13/10
Resin net with mold resistance
40.0/34.0
R-410A / 2.087,5
6.35
12.7
VP25 (O.D. 32 / I.D. 25)
1~/50/60/220-240/220
15
BRC4C61
BRC1D52 / BRC1E52A/B
34
BYK71FJW1
70x1,440x800
9.5
18/15
42.0/37.0
9.52
15.9
200 mm or more
200 mm or more
20 mm or more
Nr.
1
2
3
4
5
6
7
Suspension bolt
9
1,000 or more
Required installation space
10
Description
NOTES
Indoor Units
4-M4 hole
Name
3D038840
FXKQ63MA
FXKQ63MA
1,500 mm or
more
20 mm or more
Nr.
1
2
3
4
5
1,350 (Suspension position)
1,400 (Ceiling opening)
6
7
8
Suspension bolt
1,000 or more
(Required
installation space)
6-M4 hole
10
200 mm or more
Name
Description
NOTES
117
FXDQ-M9
FXDQ-M9
For easy mounting, the drain pan can be located to the left or
BRC1E52A/B
BRC4C62
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
FXDQ
kW
kW
kW
kW
mm
mm
mm
mm
kg
118
20M9
2.2
2.5
25M9
2.8
3.2
0.050
0.050
230
502
652
250
17
Unpainted
Galvanised steel
6.7/5.2
6.7/5.2
7.4/5.8
7.4/5.8
Part name
Liquid pipe connection ( 6.35)
Gas pipe connection ( 12.7)
Drain hole (o.d. 27.2 - i.d. 21.6)
Transmission wiring port
Power supply wiring port
Service space
Switch box
Nameplate
250 or more
(Suspension position)
Nr
1
2
3
4
5
6
7
8
Indoor Units
300 or more
3TW25774-1
119
FXDQ-A
only 240mm
FXDQ15-32A
BRC1E52A/B
BRC4C65
fan motor
installation speed
750 mm
///////////////////////////////////////////////////////////////////////////////////////
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
FXDQ
kW
kW
kW
kW
mm
mm
mm
mm
kg
120
15A
1.7
1.9
20A
2.2
2.5
25A
2.8
3.2
32A
3.6
4.0
0.071
0.068
40A
4.5
5.0
0.078
0.075
50A
5.6
6.3
0.099
0.096
63A
7.1
8.0
0.110
0.107
200
750
950
1,150
26
29
620
240
22
Galvanised steel / Non painted
8.0/7.2/6.4
10.5/9.5/8.5
7.5/7.0/6.4
30/10
50
32/31/27
12.5/11.0/10.0
44/15
16.5/14.5/13.0
54
36/34/30
15.9
Indoor Units
FXDQ15-32A
FXDQ40-50A
121
FXQQ15A
122
Indoor Units
FXDQ20-25A
FXDQ40A
123
FXDQ63A
124
125
Indoor Units
FXSQ-A
FXSQ-A
and static pressure and adjusts it towards the nominal air flow,
whatever the length of duct, making installation easier and
guaranteeing comfort. Moreover, the ESP can be changed via
the wired remote control to optimize the supply air volume
Discretely concealed in the ceiling: only the suction and
discharge grilles are visible
15 class unit especially developed for small or well-insulated
rooms, such as hotel bedrooms, small offices, etc.
Reduced energy consumption thanks to specially developed DC
fan motor
Fresh air intake integrated in the same system thus reducing
installation cost as no additional ventilation is required
BRC1E52A/B
BRC4C65
Flexible installation
////////////////////////////////////
//////////////////////////////////////////
//////////////////////////////////////////
speed
///////////////////////////////////////////////////////////////////////////////////////
126
Time
saving
Indoor Units
50
+/- 10%
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
FXSQ
15A
20A
25A
32A
40A
50A
63A
80A
100A
125A
140A
kW
kW
kW
kW
mm
mm
mm
mm
kg
1.7
1.9
2.2
2.5
41
38
2.8
3.2
3.6
4.0
45
42
4.5
5.0
92
89
5.6
6.3
95
92
7.1
8.0
95
92
9.0
10.0
121
118
11.2
10.0
157
154
14.0
26.0
214
211
16.0
18.0
245
1550
800
47
51
mm
kg
m/min 8.7/7.5/6.5
m/min 8.7/7.5/6.5
Pa
dBA
dBA 29.5/28/25
dBA 31.5/29/26
mm
mm
Hz/V
A
245
550
800
23,5
9/7.5/6.5
9/7.5/6.5
245
700
800
24
9.5/8/7
9.5/8/7
295
29
35,5
Not painted
Galvanised steel plate
28,5
245
1000
800
245
1400
800
36,5
46
127
FXMQ-P7/FXMQ-MA9
and static pressure and adjusts it towards the nominal air flow,
whatever the length of duct, making installation easier and
guaranteeing comfort. Moreover, the ESP can be changed via
the wired remote control to optimize the supply air volume
High external static pressure up to 200Pa facilitates extensive
duct & grille network.
Discretely concealed in the ceiling: only the suction and
discharge grilles are visible
Reduced energy consumption thanks to specially developed DC
fan motor
Fresh air intake integrated in the same system thus reducing
installation cost as no additional ventilation is required
FXMQ50P
BRC1E52A/B
BRC4C65
////////////////////////////////////
Flexible installation
- air suction direction can be altered from rear to bottom suction
//////////////////////////////////////////
//////////////////////////////////////////
speed
///////////////////////////////////////////////////////////////////////////////////////
128
Time
saving
Indoor Units
50
+/- 10%
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
FXMQ-P7/FXMQ-MA9
kW
kW
kW
kW
mm
mm
mm
mm
kg
mm
kg
m/min
m/min
Pa
50P7
5.6
6.3
0.110
0.098
80P7
9.0
10.0
0.171
0.159
300
1,000
35
18/16.5/15
18/16.5/15
61/41/39/37
41/39/37
mm
mm
6.35
12.7
100P7
11.2
12.5
0.176
0.164
125P7
14.0
16.0
0.241
0.229
1,400
700
350
dBA
dBA
dBA
Hz/V
A
63P7
7.1
8.0
0.120
0.108
200MA9
22.4
25.0
1.294
1.294
250MA9
28.0
31.5
1.465
1.465
470
1,380
1,100
137
-
46
Unpainted
Galvanised steel plate
BYBS71DJW1
BYBS125DJW1
White (10Y9/0.5)
55x1,100x500
55x1,500x500
-x-x4.5
6.5
19.5/17.8/16
25/22.5/20
32/27.5/23
39/33.5/28
58/-/50
72/-/62
19.5/17.8/16
25/22.5/20
32/27.5/23
39/33.5/28
-/-/200/100
221/132
270/191
Resin net with mold resistance
64/67/65/70/-/42/40/38
43/41/39
44/42/40
48/-/45
42/40/38
43/41/39
44/42/40
-/-/R-410A / 2.087,5
9.52
15.9
19.1
22.2
VP25 (I.D. 25/O.D. 32)
PS1B
1~/50/60/220-240/220
16
15
BRC4C65
BRC2E52C (heat recovery type) / BRC3E52C (heat pump type)
BRC1D52 / BRC1E52A/B
129
DETAIL B
VIEW A-A
350 or more
(Service space)
Suspension bolt
500 or more
6 x M5 (On circumference)
DETAIL B
(Service space)
Item
1
2
3
4
5
6
7
8
9
10
Name
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Remote control wiring connection
Power supply connection
Drain hole
Air filter
Air suction side
Air discharge side
Nameplate
Description
6.35 Flare connection
12.70 Flare connection
VP25 (0D 32, ID 25)
VP20 (0D 32, ID 25)
-
3TW32694-1
NOTES
Refer to outlook drawing for installing optional accessories when installing optional accessories.
The required ceiling depth varies according to the configuration of the specific system.
For maintenance of the air filter, it is necessary to provide a service access panel.
Refer to the filter installation method drawing.
FXMQ63-80P7
FXMQ63-80P7
(Knock out hole)
Fresh air intake position
350 or more
(Service space)
Suspension bolt
Detail B
500 or more
(Service space)
(On circumference)
Item Name
1
Liquid pipe connection
2
Gas pipe connection
3
Drain pipe connection
4
Remote control wiring connection
5
Power supply connection
6
Drain hole
7
Air filter
8
Air suction side
9
Air discharge side
10 Nameplate
390 or more
(Service space)
(Ceiling opening)
Description
9.52 Flare connection
15.90 Flare connection
VP25 (OD 32, ID 25)
VP25 (OD 32, ID 25)
-
Detail B
(Ceiling opening)
NOTES
View A-A
3TW31234-1B
130
350 or more
(Service space)
Suspension bolt
Detail B
500 or more
(Service space)
(On circumference)
Detail B
View A-A
Description
9.52 Flare connection
15.90 Flare connection
VP25 (OD 32, ID 25)
VP25 (OD 32, ID 25)
-
Indoor Units
Item Name
1
Liquid pipe connection
2
Gas pipe connection
3
Drain pipe connection
4
Remote control wiring connection
5
Power supply connection
6
Drain hole
7
Air filter
8
Air suction side
9
Air discharge side
10 Nameplate
(Ceiling opening)
(Ceiling opening)
390 or more
(Service space)
NOTES
1.
2.
3.
4.
3TW31254-1B
FXMQ200-250MA9
FXMQ-MA9
Piping size (field supply)
34 - 4.7 hole
(All around)
Indoor unit
Gas side
Liquid side
FXMQ200MA9
9.5
FXMQ250MA9
9.5
No.
34 - 4.7 hole
(All around)
A View
Approx
650 or more
(Service space)
32 - 7 hole
(All around)
Discharge side
A View
Name
Description
Flare connection
Ground terminal
Switch box
Hook
Suction flange
10
Attached piping
11
Name plate
12
13
M10
Brazing
PS1B Internal thread
Major dia. 33.349
Minor dia. 30.391
16 - 8 hole
(All around)
NOTES
3D038851A
131
H (max ESP)
Lower limit of ESP
(max ESP)
M (max ESP)
L (max ESP)
M (std ESP)
H (std ESP)
L (std ESP)
FXMQ50P7
L
Lower limit of ESP
Airflow [m3/min]
Airflow [m3/min]
Airflow [m3/min]
1.
2.
3TW32698-1
NOTES
FXMQ63P7
Fan characteristics (1)
H (max ESP)
Upper limit of ESP
(max ESP)
M (max ESP)
Lower limit of ESP
(max ESP)
L (max ESP)
H (std ESP)
M (std ESP)
Lower limit of ESP
(std ESP)
L (std ESP)
Airflow [m3/min]
FXMQ63P7
H
M
L
Lower limit of ESP
Airflow [m3/min]
Airflow [m3/min]
1.
2.
132
NOTES
3TW32708-1
H (max ESP)
Upper limit of ESP
(max ESP)
M (max ESP)
Lower limit of ESP
(max ESP)
L (max ESP)
H (std ESP)
M (std ESP)
Lower limit of ESP
(std ESP)
L (std ESP)
FXMQ80P7
H
M
L
Lower limit of ESP
Airflow [m3/min]
Airflow [m3/min]
Indoor Units
Airflow [m3/min]
1.
2.
3TW32718-1
NOTES
FXMQ100P7
Fan characteristics (1)
H (max ESP)
Upper limit of ESP
(max ESP)
M (max ESP)
L (max ESP)
Upper limit of ESP
(std ESP)
H (std ESP)
M (std ESP)
Lower limit of ESP
(std ESP)
L (std ESP)
Airflow [m3/min]
FXMQ100P7
L
Lower limit of ESP
Airflow [m3/min]
Airflow [m3/min]
1.
2.
3TW32728-1
NOTES
133
FXMQ125P7
H (max ESP)
Upper limit of ESP
(max ESP)
M (max ESP)
L (max ESP)
H (std ESP)
M (std ESP)
H
M
L
L
Lower limit of ESP
Airflow [m3/min]
Airflow [m3/min]
Airflow [m3/min]
1.
2.
3TW32738-1
NOTES
FXMQ200MA
FXMQ200MA
50Hz 220V
(mmH2O) (PA)
(mmH2O)
S
f E
it o
lr im P)
pe ES
Up igh
(H
High
(High ESP)
Low
(High ESP)
P
ES
t of
imi ESP)
l
r
d
pe
Up andar
(St
P
ES
it of
lim ) High
r
e
Low h ESP (Standard
(Hig
ESP)
Low
(Standard ESP)
ESP
limit of
Lower rd ESP)
a
d
(Stan
3D035172
NOTES
1. The remote control can be used to switch between high and low.
2. The air flow is set to standard before leaving the factory. It is possible to switch between
standard ESP and high ESP by changing the switch in the indoor unit electrical box.
134
(mmH2O)
ES
f
it o
lim P)
r
pe ES
Up igh
(H
High
(High ESP)
Low
(High ESP)
ES
of
mit
er li )
Low h ESP
(Hig
SP
of E
mit
)
er li d ESP
p
p
U ndar
(Sta
High
(Standard
ESP)
Low
(Standard ESP)
Indoor Units
of ESP
Lower limit P)
ES
(Standard
3D035173A
NOTES
1. The remote control can be used to switch between high and low.
2. The air flow is set to standard before leaving the factory. It is possible to switch between
standard ESP and high ESP by changing the switch in the indoor unit electrical box.
135
FXAQ-P
FXAQ15-32P
fan motor
The air is comfortably spread up and downwards thanks to 5
different discharge angles that can be programmed via the
remote control
Maintenance operations can be performed from the front of the
unit
BRC1E52A/B
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Weight
Casing
Fan-Air flow rate - 50Hz
Air filter
Sound power level
Sound pressure level
Refrigerant
Piping connections
Power supply
Current - 50Hz
Control systems
136
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
Unit
Colour
Cooling
High/Low
Type
Cooling
Nom.
Cooling
High/Low
Type / GWP
Liquid
OD
Gas
OD
Drain
Phase/Frequency/Voltage
Maximum fuse amps (MFA)
Infrared remote control
Simplified wired remote control for hotel applications
Wired remote control
FXAQ
kW
kW
kW
kW
mm
mm
mm
kg
m/min
dBA
dBA
mm
mm
Hz/V
A
15P
1.7
1.9
0.017
0.025
20P
2.2
2.5
0.019
0.029
25P
2.8
3.2
0.028
0.034
BRC7E518
32P
3.6
4.0
0.030
0.035
290
40P
4.5
5.0
0.020
0.020
795
50P
5.6
6.3
0.033
0.039
63P
7.1
8.0
0.050
0.060
1,050
238
11
7.0/4.5
7.5/4.5
34.0/29.0
35.0/29.0
14
White (3.0Y8.5/0.5)
8/5
8.5/5.5
12/9
Washable resin net
36.0/29.0
37.5/29.0
39.0/34.0
R-410A / 2.087,5
6.35
12.7
VP13 (I.D. 13/O.D. 18)
1~/50/220-240
16
BRC7EB518
BRC1E52A/B / BRC1D52
15/12
19/14
42.0/36.0
47.0/39.0
9.52
15.9
30 or more
(Required space)
Approx 400
Dimensions for
full open front panel
50 or more
(Required space)
90 or more
Piping direction
Piping direction
Piping direction
(Required space)
50 or more
(Required space)
Outside line
120 or less
2500 or more
For installation
in high spaces
Approx 475
Approx 460
(Filter part)
Approx 290
(Flexible tube part)
Filter part
80 hole
Approx 415
Mounting location
Name
Description
Front panel
Front grill
Air outlet
Gas pipe
Liquid pipe
Drain hose
Grounding terminal
Right side pipe connection hole
Left side pipe connection hole
3D065064A
NOTES
In case of using infrared remote control, this position will be a signal receiver. Refer to the drawing of
infrared remote control in detail.
Indoor Units
Nr
1
2
3
4
5
6
7
8
9
80 hole
Piping and
Wiring intake
FXAQ40-50P
FXAQ40-50P
30 or more
(Required space)
Approx 400
(Required space)
90 or more
Piping direction
Dimensions for
full open front panel
Piping direction
Piping direction
(Required space)
Outside line
2500 or more
50 or more
For installation
(Required space) in high spaces
120 or less
Approx 475
Approx 460
(Filter part)
Filter part
80 hole
Approx 290
(Flexible tube part)
Approx 415
80 hole
Piping and
Wiring intake
Mounting location
Nr
1
2
3
4
5
6
7
8
9
Name
Front panel
Front grill
Air outlet
Gas pipe
Liquid pipe
Drain hose
Grounding terminal
Right side pipe connection hole
Left side pipe connection hole
Description
3D065065A
NOTES
In case of using infrared remote control, this position will be a signal receiver. Refer to the drawing of
infrared remote control in detail.
137
90 or more
(Required space)
Piping direction
30 or more
(Required space)
Approx 400
Dimensions for
full open
front panel
Piping direction
Piping direction
50 or more
50 or more
(Required space)
(Required space)
Outside line
2500 or more
For installation
in high spaces
120 or less
Approx 475
Approx 460
Filter part
Filter part
80 hole
Approx 415
Mounting location
Nr
1
2
3
4
5
6
7
8
9
138
Name
Front panel
Front grill
Air outlet
Gas pipe
Liquid pipe
Drain hose
Grounding terminal
Right side pipe connection hole
Left side pipe connection hole
Description
80 hole
Piping and
Wiring intake
3D065066A
NOTES
In case of using infrared remote control, this position will be a signal receiver. Refer to the drawing of
infrared remote control in detail.
139
Indoor Units
FXHQ-A
FXHQ63A
BRC1E52A-B
BRC7G53
30 or more
(Service space)
Air outlet
Air inlet
30 or more
(Service space)
////////////////////////////
Obstruction
////////////////////////////////////
//////////////////////
//////////////////////
////////////////////////////////////////////
300
Stylish unit blends easily with any interior. The flaps close
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Weight
Casing
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
FXHQ
kW
kW
kW
kW
mm
mm
mm
kg
Unit
Colour
Material
Fan-Air flow rate Cooling
High/Nom./Low
m/min
50Hz
Heating
High/Nom./Low
m/min
Air filter
Type
Sound power level
Cooling
Nom.
dBA
Sound pressure level Cooling
High/Nom./Low
dBA
Heating
High/Nom./Low
dBA
Refrigerant
Type / GWP
Piping connections
Liquid
OD
mm
Gas
OD
mm
Drain
Power supply
Phase/Frequency/Voltage
Hz/V
Current - 50Hz
Maximum fuse amps (MFA)
A
Control systems
Infrared remote control
Simplified wired remote control for hotel applications
Wired remote control
140
32A
3.6
4.0
0.107
0.107
960
24
14.0/12.0/10.0
14.0/12.0/10.0
36.0/34.0/31.0
36.0/34.0/31.0
63A
7.1
8.0
0.111
0.111
235
1,270
690
33
Fresh White
Resin
20.0/17.0/14.0
20.0/17.0/14.0
Resin net with mold resistance
37.0/35.0/34.0
37.0/35.0/34.0
R-410A / 2.087,5
6.35
12.7
100A
11.2
12.5
0.237
0.237
1,590
39
29.5/24.0/19.0
29.5/24.0/19.0
44.0/37.0/34.0
44.0/37.0/34.0
9.52
15.9
Indoor Units
FXHQ32A
FXHQ63A
141
FXUQ-A
FXUQ-A
more flaps can be easily closed via the wired remote control
BRC1E52A/B
BRC7CB58
Stylish unit blends easily with any interior. The flaps close
installation speed
VP20
500
//////////////////////////////////////////////
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Weight
Casing
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
Unit
Colour
Material
Fan-Air flow rate Cooling
High/Nom./Low
50Hz
Heating
High/Nom./Low
Air filter
Type
Sound power level
Cooling
Nom.
Sound pressure level Cooling
High/Nom./Low
Heating
High/Nom./Low
Refrigerant
Type / GWP
Piping connections
Liquid
OD
Gas
OD
Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
Control systems
Infrared remote control
Simplified wired remote control for hotel applications
Wired remote control
142
FXUQ
kW
kW
kW
kW
mm
mm
mm
kg
71A
8.0
9.0
0.090
0.073
100A
11.2
12.5
0.200
0.179
198
950
950
26
27
Fresh White
Resin
m/min
m/min
dBA
dBA
dBA
mm
mm
Hz/V
A
22.5/19.5/16.0
22.5/19.5/16.0
31.0/26.0/21.0
31.0/26.0/21.0
Resin net with mold resistance
-
40.0/38.0/36.0
40.0/38.0/36.0
47.0/44.0/40.0
47.0/44.0/40.0
R-410A / 2.087,5
9.52
15.9
I.D. 20/O.D. 26
1~/50/60/220-240/220-230
16
BRC7C58
BRC1E52A/B / BRC1D52
Indoor Units
FXUQ-A
143
FXNQ-A
FXNQ-A
BRC1E52A-B
BRC4C65
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Weight
Casing
Fan-Air flow rate - 50Hz
Fan-External static pressure - 50Hz
Air filter
Sound power level
Sound pressure level
Refrigerant
Piping connections
Power supply
Current - 50Hz
Control systems
Nom.
Nom.
Cooling
Heating
Unit
Unit
Color
Material
Cooling
High/Nom.
Nom.
Nom.
Height
Width
Depth
High/Low
Cooling
Nom.
Cooling
High/Low
Type / GWP
Liquid
OD
Gas
OD
Drain
Phase/Frequency/Voltage
Maximum fuse amps (MFA)
Infrared remote control
Simplified wired remote control for hotel applications
Wired remote control
144
FXNQ
kW
kW
kW
kW
mm
mm
mm
kg
m/min
Pa
dBA
dBA
mm
mm
Hz/V
A
20A
2.2
2.50
25A
2.8
3.20
0.071
0.068
32A
3.6
4.0
40A
4.5
5.0
0.078
0.075
50A
5.6
6.3
0.099
0.096
63A
7.1
8.00
0.110
0.107
620
750
950
1,150
26
29
200
22
8.0/6.4
30/10
Unpainted
Galvanised steel plate
10.5/8.5
12.5/10.0
44/15
16.5/13.0
9.52
15.9
FXLQ-P
back plate
Its low height enables the unit to fit perfectly beneath a window
Stylish modern casing finished in pure white (RAL9010) and iron
>20mm
1750mm
////////////////////////////////
Floor standing
100mm
///////////////////////////////////////////////////////////
///////////////////////////////////////////////////////////
>20mm
//////////////////
FXLQ20,25P
BRC1E52A/B
BRC4C65
////////////////////////////////
Wall mounted
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Weight
Casing
Fan-Air flow rate - 50Hz
Air filter
Sound power level
Sound pressure level
Refrigerant
Piping connections
Power supply
Current - 50Hz
Control systems
Nom.
Nom.
Cooling
Heating
Unit
Nom.
Nom.
Height
Width
Depth
Unit
Colour
Cooling
High/Low
Type
Cooling
Nom.
Cooling
High/Low
Type / GWP
Liquid
OD
Gas
OD
Drain
Phase/Frequency/Voltage
Maximum fuse amps (MFA)
Infrared remote control
Simplified wired remote control for hotel applications
Wired remote control
FXLQ
kW
kW
kW
kW
mm
mm
mm
kg
m/min
dBA
dBA
mm
mm
Hz/V
A
20P
2.2
2.5
25P
2.8
3.2
0.049
0.049
1,000
27
7/6
32P
3.6
4.0
40P
4.5
5.0
50P
5.6
6.3
0.090
0.090
600
1,140
232
32
Fresh white (RAL9010) / Dark grey (RAL7011)
8/6
11/8.5
14/11
Resin net
35/32
38/33
39/34
R-410A / 2.087,5
6.35
12.7
O.D. 21 (Vinyl chloride)
1~/50/60/220-240/220
15
BRC4C65
BRC2E52C (heat recovery type) / BRC3E52C (heat pump type)
BRC1D52 / BRC1E52A/B
63P
7.1
8.000
0.110
0.110
1,420
38
16/12
40/35
9.52
15.9
145
20 or more
100 or more
1750 or more
100 or more
Discharge
Suction
Front of face
1000 or more
Base
Item
1
2
3
4
5
Name
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Switch box
Air f lter
Description
6.4 Flare connection
12.7 Flare connection
O.D.21
3TW32294-1
FXLQ32-40P
);/43
RUPRUH
RUPRUH
RUPRUH
RUPRUH
'LVFKDUJH
6XFWLRQ
)URQWRIIDFH
RUPRUH
%DVH
5HTXLUHGLQVWDOODWLRQVSDFH
3LSLQJKROHUHDU
[2EORQJKROH
+ROHIRUIHDUPRXQWLQJ
/HYHODGMXVWLQJVFUHZLQVWDQGDUGDFFHVVRU\
[0
[2EORQJKROH
+ROHIRUI[LQJWRWKHIRRU
:LULQJKROHERWWRP
3LSLQJKROHERWWRP
,WHP
1DPH
/LTXLGSLSHFRQQHFWLRQ
*DVSLSHFRQQHFWLRQ
'UDLQSLSHFRQQHFWLRQ
6ZLWFKER[
$LUIOWHU
'HVFULSWLRQ
)ODUHFRQQHFWLRQ
)ODUHFRQQHFWLRQ
2'
7:
146
RUPRUH
RUPRUH
'LVFKDUJH
6XFWLRQ
)URQWRIIDFH
RUPRUH
%DVH
5HTXLUHGLQVWDOODWLRQVSDFH
3LSLQJKROHUHDU
0RGHO
);/
);/
/HYHODGMXVWLQJVFUHZLQVWDQGDUGDFFHVVRU\
[0
$
%
Indoor Units
[2EORQJKROH
+ROHIRUIHDUPRXQWLQJ
[2EORQJKROH
+ROHIRUI[LQJWRWKHIRRU
:LULQJKROHERWWRP
3LSLQJKROHERWWRP
,WHP
1DPH
/LTXLGSLSHFRQQHFWLRQ
*DVSLSHFRQQHFWLRQ
'UDLQSLSHFRQQHFWLRQ
6ZLWFKER[
$LUIOWHU
'HVFULSWLRQ
$)ODUHFRQQHFWLRQ
%)ODUHFRQQHFWLRQ
2'
7:
147
overview
Depending on the application, Split and Sky Air
indoor units can be connected to our VRV IV
and VRV III-S outdoor units. Refer to the outdoor unit
portfolio for combination restrictions.
RXYSQ-P8Y13
Type
Model
Ceiling
mounted
cassette
Concealed
ceiling
Wall
mounted
Ceiling
suspended
Floor
standing
1
2
3
Product name
20
25
FCQG-F
35
42
50
60
71
Fully flat
cassette
FFQ-C
FDBQ-B
FDXS-F(9)
FBQ-D
Daikin Emura
Wall mounted unit
FTXG-LW/LS
CTXS-K
FTXS-K
FTXS-G
FHQ-C
FVXG-K
FVXS-F
FLXS-B(9)
148
15
RXYQ-T
RYYQ-T
RXYSQ-P8V13
FXSQ-A
VRV indoor unit
FXFQ-A
FVXG-K
Nexura
BPMKS967A2
FTXG-LW
Indoor Units
RYYQ-T
RXYQ-T
Daikin Emura
BPMKS967A2
BPMKS967A2
VRV III-S heat pump
RXYSQ-P8V
RXYSQ-P8Y
BPMKS967A
Branch provider
To connect Split and Sky Air indoor units
to VRV outdoor units
Branch provider
BPMKS967B2
BPMKS967B2
mm
kg
BPMKS967B3
1~2
1~3
14.2
71+71
20.8
60+71+71
180x294x350
149
ARGUE CARDS
emura
Daikin Emura
Form. Function. Redesigned
150
Benefits
FTXG-LW/S
FTXG-LS
Indoor Units
ARC466A1
Indoor unit
Casing
Dimensions
Weight
Air filter
Fan - Air flow rate
Colour
Unit
HeightxWidthxDepth
Unit
Type
High/Nom./Low/Silent operation
Cooling
High/Nom./Low/Silent operation
Heating
Sound power level
Cooling
Heating
High/Nom./Low/Silent operation
Sound pressure level Cooling
High/Nom./Low/Silent operation
Heating
Power supply
Phase / Frequency / Voltage
Control systems
Infrared remote control
FTXG
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Hz / V
20LW/S
25LW/S
35LW/S
White/Silver
303x998x212
12
Removable / washable / mildew proof
8.9/6.6/4.4/2.6
10.9/7.8/4.8/2.9
10.2/8.4/6.3/3.8
11.0/8.6/6.3/3.8
12.4/9.6/6.9/4.1
54
59
56
59
38/32/25/19
45/34/26/20
40/34/28/19
41/34/28/19
45/37/29/20
1~ / 50 / 220-240
ARC466A1
50LW/S
10.9/8.9/6.8/3.6
12.6/10.5/8.1/5.0
60
60
46/40/35/32
47/41/35/32
151
FTXG50LW/S
152
153
Indoor Units
C/FTXS-K
Indoor unit
Casing
Dimensions
Weight
Air filter
Fan - Air flow rate
Sound power level
Sound pressure level
Power supply
Control systems
154
CTXS15K
Colour
Unit
HeightxWidthxDepth
Unit
Type
High/Nom./Low/Silent operation
Cooling
Heating
High/Nom./Low/Silent operation
Cooling
Heating
High/Nom./Low/Silent operation
Cooling
Heating
High/Nom./Low/Silent operation
Phase / Frequency / Voltage
Infrared remote control
mm
kg
C/FTXS-K
ARC466A6
CTXS35K
FTXS 20K
FTXS 35K
White
289x900x215
FTXS 42K
FTXS 50K
FTXS 60G
FTXS 71G
298x900x215
290x1,050x250
11
12
Removable / washable / mildew proof
8.8/6.7/4.7/3.9 9.1/7.0/5.0/3.9 11.2/8.5/5.8/4.1 11.2/11.2/7.0/4.1 11.9/11.9/7.4/4.5 16.0/16.0/11.3/10.1 17.2/17.2/11.5/10.5
9.5/7.8/6.0/4.3 10.0/8.0/6.0/4.3 12.1/9.3/6.5/4.2 12.4/10.0/7.8/5.2 13.3/10.8/8.4/5.5 17.2/14.9/12.6/11.3 19.5/16.7/14.2/12.6
58
59
60
63
58
59
60
59
62
40/32/24/19 41/33/25/19 45/37/29/19 45/39/33/21 46/40/34/23 45/41/36/33 46/42/37/34
40/34/27/19 41/34/27/19 45/39/29/19 45/39/33/22 47/40/34/24 44/40/35/32 46/42/37/34
1~ / 50 / 220-240
ARC466A6
ARC452A3
289x780x215
8
FTXS 25K
Indoor Units
CTXS15K / FTXS20-25K
FTXS35-42K / CTXS35K
155
FTXS60G
156
Indoor Units
FTXS71G
157
Logo grijs
ARGUE CARDS
Pure comfort
and design
radiant
heat
Comfort is key
Benefits
Vertical autoswing
Weekly timer
Online controller
158
FVXG-K
FVXG-K
Indoor Units
ARC466A2
Indoor unit
Casing
Dimensions
Weight
Air filter
Fan - Air flow rate
Colour
Unit
HeightxWidthxDepth
Unit
Type
High/Nom./Low/Silent operation
Cooling
High/Nom./Low/Silent operation
Heating
Sound power level
Cooling
Heating
High/Nom./Low/Silent operation
Sound pressure level Cooling
High/Nom./Low/Silent operation/Radiant heat
Heating
Power supply
Phase / Frequency / Voltage
Control systems
Infrared remote control
FVXG
25K
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Hz / V
8.9/8.9/5.3/4.5
9.9/7.8/5.7/4.7
38/32/26/23
39/32/26/22/19
35K
Fresh white (6.5Y 9.5/0.5)
600x950x215
22
Removable / washable / mildew proof
9.1/9.1/5.3/4.5
10.2/8.0/5.8/5.0
52
53
39/33/27/24
40/33/27/23/19
1~ / 50 / 220-240
ARC466A2
50K
10.6/10.3/7.3/6.0
12.2/10.0/7.8/6.8
58
60
44/40/36/32
46/40/34/30/26
(1) EER/COP according to Eurovent 2012, for use outside EU only (2) Nominal efficiency: cooling at 35/27 nominal load, heating at 7/20 nominal load
159
FVXG50K
160
FVXS-F
FVXS-F
Indoor Units
ARC452A1
Indoor unit
Casing
Dimensions
Weight
Air filter
Fan - Air flow rate
Colour
Unit
HeightxWidthxDepth
Unit
Type
High/Nom./Low/Silent operation
Cooling
High/Nom./Low/Silent operation
Heating
Sound power level
Cooling
Heating
High/Nom./Low/Silent operation
Sound pressure level Cooling
High/Nom./Low/Silent operation
Heating
Power supply
Phase / Frequency / Voltage
Control systems
Infrared remote control
FVXS
25F
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Hz / V
8.2/8.2/4.8/4.1
8.8/6.9/5.0/4.4
38/32/26/23
38/32/26/23
35F
White
600x700x210
14
Removable / washable / mildew proof
8.5/8.5/4.9/4.5
9.4/7.3/5.2/4.7
52
52
39/33/27/24
39/33/27/24
1~ / 50 / 220-240
ARC452A1
50F
10.7/10.7/7.8/6.6
11.8/10.1/8.5/7.1
60
60
44/40/36/32
45/40/36/32
(1) EER/COP according to Eurovent 2012, for use outside EU only (2) Nominal efficiency: cooling at 35/27 nominal load, heating at 7/20 nominal load
161
unit (mm)
Timer lamp
Signal receiver
Air outlet
selection
switch
(Inside)
95 (Half concealed)
Signal transmitter
Name plate
Drain
socket
85
Air flow
Required space
For performance
50 MIN
(for
maintenance)
(for
performance)
Up/down (automatic)
Cool, dry
Cooling
/ dry
Heat
(Heat pump model)
Right/left (manual)
Upper air outlet
(Wall hole)
(Wall hole)
50 MIN
VP20
I.D. J20
O.D. J26
L 220
3D056135A
FVXS50F
FVXS50F
unit (mm)
Timer lamp
Signal receiver
Air outlet
selection
switch
(Inside)
95 (Half concealed)
Signal transmitter
Name plate
Drain
socket
For performance
50 MIN
(for
performance)
Right/left (manual)
Upper air outlet
(Wall hole)
(Wall hole)
50 MIN
(for
maintenance)
Required space
Up/down (automatic)
Cooling / dry Cool, dry
Heat
(Heat pump model)
Upward air flow
limit (OFF)
162
VP20
I.D. J20
O.D. J26
L 220
85
Air flow
3D056136A
FLXS-B(9)
Vertical auto swing moves the discharge flaps up and down for
FLXS-B
Indoor Units
ARC433B67
Indoor unit
Casing
Dimensions
Weight
Air filter
Fan - Air flow rate
Colour
Unit
HeightxWidthxDepth
Unit
Type
High/Nom./Low/Silent operation
Cooling
High/Nom./Low/Silent operation
Heating
Sound power level
Cooling
Heating
High/Nom./Low/Silent operation
Sound pressure level Cooling
High/Nom./Low/Silent operation
Heating
Power supply
Phase / Frequency / Voltage
Control systems
Infrared remote control
FLXS
25B
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Hz / V
35B9
Almond white
490x1,050x200
16
7.6/7.6/6.0/5.2
9.2/8.3/7.4/6.6
51
51
37/34/31/28
37/34/31/29
1~ / 50/60 / 220-240/220-230
50B
60B
Almond white
490x1,050x200
17
Removable / washable / mildew proof
8.6/7.6/6.6/5.6
11.4/11.4/8.5/7.5
12.0/10.7/9.3/8.3
12.8/10.4/8.0/7.2
12.1/9.8/7.5/6.8
12.8/10.6/8.4/7.5
53
60
59
59
38/35/32/29
47/43/39/36
48/45/41/39
46/36/33/30
46/41/35/33
47/42/37/34
1~ / 50 / 220-240
1~ / 50/60 / 220-240/220-230
ARC433B67
(1) EER/COP according to Eurovent 2012, for use outside EU only (2) Nominal efficiency: cooling at 35/27 nominal load, heating at 7/20 nominal load
163
FLXS50-60B
164
Indoor Units
FLXS25-35B(9)
FLXS50-60B
165
Hot water
Efficient hot water production for underfloor
heating, radiators and air handling units, or
for producing hot water for sinks, baths and
showers. Integrating heat recovery into the
VRV system means that the production of hot
water is virtually free.
166
Hot water
Low temperature hydrobox
HXY-A168
Hot Water
167
HXY-A
electric heater
Liquid pipe
Gas pipe
F1, F2 communication
Hot/cold water
HXY-A
Indoor unit
Cooling capacity
Heating capacity
Dimensions
Weight
Casing
Sound pressure level
Operation range
Refrigerant
Refrigerant circuit
Water circuit
Power supply
Current
168
Nom.
Nom.
Unit
Unit
Colour
Material
Nom.
Heating
HeightxWidthxDepth
Ambient
Water side
Type / GWP
Gas side diameter
Liquid side diameter
Piping connections diameter
Phase/Frequency/Voltage
Recommended fuses
Min.~Max.
Min.~Max.
HXY
kW
kW
mm
kg
dBA
C
C
mm
mm
inch
Hz/V
A
080A
8.0
9.0
125A
12.5
14.0
890x480x344
44
White
Precoated sheet metal
-20~24
25~45
R-410A / 2.087,5
15.9
9.5
G 11/4 (female)
1~/50/220-240
6~16
3D079938
HXY-A
ESP (kPa)
HXY-A
Flow (l/m)
NOTES
1
2
Selecting a flow outside the curves can cause damage to or malfunctioning of the unit. See also minimum and maximum allowed flow in technical specifications.
Water quality must be according to EN directive EC 98/83 EC.
3D079876
169
Hot Water
Service door
HXHD-A
HXHD-A
EKHTS-AC
EKHWP-B
Liquid pipe
Gas pipe
Discharge gas pipe
F1, F2 communication
Hot water
Daikin
solar panel
45C - 75C
Domestic hot water
25C - 75C
BS-Box
Domestic hot
water tank
45C - 75C
BS-Box
Heating only
hydrobox for VRV
Indoor unit
Heating capacity
Dimensions
Weight
Casing
Nom.
Unit
Unit
Colour
Material
Sound pressure level Nom.
Night quiet mode
Operation range
Heating
Domestic hot
water
Refrigerant
Refrigerant circuit
Water circuit
Power supply
Current
HeightxWidthxDepth
Level 1
Ambient
Water side
Ambient
Water side
Type / GWP
Charge
Charge
Gas side diameter
Liquid side diameter
Piping connections diameter
Heating water system
Water volume
Phase/Frequency/Voltage
Recommended fuses
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
HXHD
kW
mm
kg
dBA
dBA
C
C
CDB
C
kg
TCO2Eq
mm
mm
inch
l
Hz/V
A
(1) Sound levels are measured at: EW 55C; LW 65C (2) Sound levels are measured at: EW 70C; LW 80C (3) Field setting
170
125A
14.0
705x600x695
92
Metallic grey
Precoated sheet metal
42 (1) / 43 (2)
38
-20~20 / 24 (3)
25~80
-20~43
45~75
R-134a / 1,430
2
2.9
12.7
9.52
G 1 (female)
20~200
1~/50/220-240
20
Detail A
Scale 1/3
Left Installation
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Right installation
3TW59914-1B(1)
HXHD-A
HXHD-A
Left Installation
Upwiring
Right installation
Model
HXHD-A
A
355
B
270
C
300
Min. 600
(Space required for switch box removal)
3TW59914-1B(2)
171
Hot Water
Detail A
ESP [kPa]
(heating)
(heating)
Note:
In case of stand alone tank, available ESP during DHW mode: to be conrmed
Flow [l/min]
1. The ESP curves are the maximum ESP curve for different T types (pump rpm = 4400 T = 5C; pump rpm = 4000 for T = 10C).
The pump of the indoor module is inverter controlled and controls to have a xed T between return and leaving water temperature.
2. In case of installing a demestic hot water tank there is an additional pressure drop over the three way valve (delivered as accessory with the tank).
ESP: external static pressure
Flow: waterow through the unit
Warning:
1. Selecting a ow outside the curve can cause damage to or malfunction of the unit. See also minimum and maximum allowed water owrange
in the technical specications.
2. Water quality must be according to EN directive EC 98/83 EC.
172
3TW60669-1
EKHTS-AC
Dimensions
Weight
Tank
Heat exchanger
EKHTS
Colour
Material
Unit
EKHTS260AC
200AC
260AC
Metallic grey
Galvanised steel (precoated sheet metal)
Height
Integrated on
indoor unit
mm
Width
Depth
Empty
Unit
Water volume
Material
Maximum water temperature
Insulation
Heat loss
Quantity
Tube material
Face area
Internal coil volume
mm
mm
kg
l
C
kWh/24h
2,010
2,285
600
695
70
200
78
260
Stainless steel (EN 1.4521)
75
1.2
1.5
1
Duplex steel (EN 1.4162)
1.56
7.5
m
l
Hot Water
Accessory
Casing
EKHTS200AC
EKHWP-B
any time
insulation
Accessory
Dimensions
Weight
Tank
Heat exchanger
Unit
Width
Depth
Empty
Unit
Water volume
Maximum water temperature
Insulation
Heat loss
Domestic hot
Tube material
water
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
Charging
Tube material
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
Auxiliary solar
Tube material
heating
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
EKHWP300B
EKHWP
mm
mm
kg
l
C
kWh/24h
300B
595
615
59
300
500B
790
790
93
500
85
1.3
1.4
Stainless steel
m
l
bar
W/K
5.8
27.9
6
29
6
2,790
2,900
Stainless steel
m
l
bar
W/K
2.7
13.2
3.8
18.5
3
1,300
1,800
Stainless steel
m
l
bar
W/K
0.5
2.3
3
280
173
EKSRPS
Pump station
Save energy and reduce CO2 emissions with a solar system for
EKSRPS3
Accessory
Mounting
Dimensions
Control
Power supply
Sensor
EKSRPS
Unit
HeightxWidthxDepth
Type
Power consumption
Voltage
Solar panel temperature sensor
Storage tank sensor
Return flow sensor
Feed temperature and flow sensor
3
On side of tank
815x230x142
Digital temperature difference controller with plain text display
2
230
Pt1000
PTC
PTC
Voltage signal (3.5V DC)
mm
W
V
EKS(H/V)-P
Solar collector
Thermal solar collector for hot water production
Solar collectors can produce up to 70% of the energy needed for
production
EKSH-P
EKSV-P
Accessory
Dimensions
Weight
Volume
Surface
Coating
Absorber
Glazing
Allowed roof angle
Operating pressure
Stand still temperature
174
Unit
Unit
HeightxWidthxDepth
Outer
Aperture
Absorber
mm
kg
l
m
m
m
Min.~Max.
Max.
Max.
bar
C
EKSV21P
2,000x1,006x85
35
1.3
2.01
1.79
1.8
EKSV26P
2,000x1,300x85
EKSH26P
1,300x2,000x85
42
1.7
2.1
2.6
2.35
2.36
Micro-therm (absorption max. 96%, Emission ca. 5% +/-2%)
Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate
Single pane safety glass, transmission +/- 92%
15~80
6
200
175
Hot Water
176
3.8m
3.5m
3.3m
Free-Hanging (F)
3.0m
2.8m
3.0m
2.5m
2.5m
2.4m
2.2m
2.2m
2
Cassette (C)
S
Recessed (C)
XL
Favourable
XL
Normal
Unfavourable
XL
Installation condition
177
CYVS/M/L-DK-F/C/R
total cost
(installation + running cost) in
8000
Daikin heat pump
with Biddle air curtain*
6000
4000
2000
0
1
years
VRV
Network Solution
Biddle comfort
air curtain (ca)
Integration in a VRV total solution
* Payback period and gains calculated based upon the following: Air curtain is 9hrs/day 156 days year (1,404 hrs/year) in use. Annual energy consumption for an electric air
curtain: 3,137EUR (COP = 0.95). Typical installation cost: 1,000EUR; Typical equipment cost: 2,793EUR. Annual energy consumption for CYQS200DK100FBN and ERQ100AV: 748EUR
(COP 4.00). Typical installation cost: 2,000EUR; Typical equipment cost: 5,150EUR. Calculation based upon electricity cost: 0,1705EUR /kWh
178
CYVM150DK80CSN
CYVM150DK80RSN
Small
Heating capacity
Power input
Delta T
Casing
Dimensions
Speed 3
Fan only
Heating
Speed 3
Colour
Unit
Nom.
Nom.
Height F/C/R
Width F/C/R
Depth F/C/R
kW
kW
kW
K
mm
mm
mm
mm
m
m
kg
m/h
dBA
mm
V
Medium
CYVS100DK80
*BN/*SN
CYVS150DK80
*BN/*SN
CYVS200DK100
*BN/*SN
7.40
0.23
0.23
19
9.0
0.35
0.35
11.6
0.46
0.46
CYVS250DK140
*BN/*SN
CYVM100DK80
*BN/*SN
CYVM150DK80
*BN/*SN
CYVM200DK100
*BN/*SN
CYVM250DK140
*BN/*SN
16.2
9.2
11.0
13.4
19.9
0.58
0.37
0.56
0.75
0.94
0.58
0.37
0.56
0.75
0.94
15
16
17
14
13
15
BN: RAL9010 / SN: RAL9006
270/270/270
1,000/1,000/1,048 1,500/1,500/1,548 2,000/2,000/2,048 2,500/2,500/2,548 1,000/1,000/1,048 1,500/1,500/1,548 2,000/2,000/2,048 2,500/2,500/2,548
590/821/561
420
2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3)
1.0
1.5
2.0
2.5
1.0
1.5
2.0
2.5
56
66
83
107
57
73
94
108
1,164
1,746
2,328
2,910
1,605
2,408
3,210
4,013
47
49
50
51
50
51
53
54
R-410A / 2.087,5
9.52/16.0
9.52/19.0
9.52/16.0
9.52/19.0
Daikin wired remote control (BRC1E52A/B or BRC1D52)
230
Large
Heating capacity
Power input
Delta T
Casing
Dimensions
Speed 3
Fan only
Heating
Speed 3
Colour
Unit
Nom.
Nom.
Height F/C/R
Width F/C/R
Depth F/C/R
kW
kW
kW
K
mm
mm
mm
mm
m
m
kg
m/h
dBA
mm
V
CYVL200DK250*BN/*SN
CYVL250DK250*BN/*SN
29.4
31.1
1.50
1.88
1.50
1.88
15
14
12
BN: RAL9010 / SN: RAL9006
370/370/370
1,000/1,000/1,048
1,500/1,500/1,548
2,000/2,000/2,048
2,500/2,500/2,548
774/1,105/745
520
3.0 (1) / 2.75 (2) / 2.5 (3)
3.0 (1) / 2.75 (2) / 2.5 (3)
3.0 (1) / 2.75 (2) / 2.5 (3)
3.0 (1) / 2.75 (2) / 2.5 (3)
1.0
1.5
2.0
2.5
76
100
126
157
3,100
4,650
6,200
7,750
53
54
56
57
R-410A / 2,087.5
9.52/16.0
9.52/19.0
9.52/22.0
Daikin wired remote control (BRC1E52A/B or BRC1D52)
230
CYVL100DK125*BN/*SN
15.6
0.75
0.75
CYVL150DK200*BN/*SN
23.3
1.13
1.13
(1) Favorable conditions: covered shopping mall or revolving door entrance (2) Normal conditions: little direct wind, no opposite open doors, building with ground floor only (3) Unfavorable conditions: location at a corner or square, multiple floors and/or
open stairway
179
CYVM150DK80FSC
500
250
250
40
100
197
O9.2
Suction grid
with filter
98
27
Type
CYVS-DK-FBN/FSN
CYVM-DK-FBN/FSN
CYVL-DK-FBN/FSN
L
1,000 - 1,500
2,000 - 2,500
1,000 - 1,500
2,000 - 2,500
270
590
93
171
119
370
774
124.5 245.5
200
CU0954X-000
REMARKS
The 2,500mm large devices have 3 suspension brackets, where the third bracket is mounted at half the length of the device.
500
250
250
40
100
197
O9.2
98
27
Screw-eye M6
CYVL-DK-CBN/CSN
270
821
93
171
119
250
411
260
L
1,000 - 1,500
2,000 - 2,500
1,000 - 1,500
2,000 - 2,500
Type
CYVS-DK-CBN/CSN
CYVM-DK-CBN/CSN
370
200
181.5 563.5
360
REMARKS
180
The 2,500mm large devices have 3 suspension brackets, where the third bracket is mounted at half the length of the device.
The mounting holes for finishing profiles in a lowered ceiling (L+8) x (D+8) mm
CU0955X-000
500
250
250
40
100
197
O9.2
Suction grid
with filter
98
1500
2000
2500
10
12
101.5
1000
Type
L
H
CYVS-DK-RBN/RSN
CYVM-DK-RBN/RSN 1,000 - 1,500 270
2,000 - 2,500
CYVL-DK-RBN/RSN 1,000 - 1,500
2,000 - 2,500 370
561
80125
90
171
119
92
139
260
745
360
T
1048-1548
20482548
1048-1548
1044-1544
408 250 2044-2544 20482548
308 160 1044-1544
2044-2544
Device length
1000 / 1500
2000 / 2500
Type
CYVS-DK-RBN/RSN
CYVM-DK-RBN/RSN
CYVL-DK-RBN/RSN
27
L
M
CU0956X-000
The 2,500mm large devices have 3 suspension brackets, where the third bracket is mounted at half the length of the device.
Holes (for finishing profiles) - drain (L+8) x (E+8) mm - suction (L+8) x (G+8) mm.
REMARKS
181
Ventilation
& air handling
Daikin offers the widest range in DX
ventilation in the market.
With a variety of ventilation solutions from
small heat recovery ventilation to large scale
air handling units we help provide a fresh,
healthy and comfortable environment in
offices, hotels, stores and other commercial
environments.
182
Ventilation
& air handling
Ventilation
Heat reclaim ventilation
VAM-FA/FB186
VKM-GB(M)198
183
Ventilation
184
Ventilation
DAIKIN AIR HANDLING UNIT AND ERQ/VRV PLUG & PLAY CONNECTION
185
VAM-FA/FB
Total heat
exchanged
foul air
moisture recovery
Ideal solution for shops, restaurants or offices requiring
maximum floor space for furniture, decorations and fittings
Free cooling possible when outdoor temperature is below
indoor temperature (eg. during nighttime)
Reduced energy consumption thanks to specially developed DC
fan motor
Prevent energy losses from over-ventilation while maintaining
indoor air quality with optional CO2 sensor
Can be used as stand alone unit or integrated in the VRV system
Wide range of units: air flow rate from 150 up to 2,000 m/h
High efficiency filters available in F6 ,F7, F8 grades
Shorter installation time thanks to easy adjustment of nominal
air flow rate, so less need for dampers compared with traditional
installation.
Specially developed heat exchange element with High
Efficiency Paper (HEP)
No drain piping needed
Can operate in over- and under pressure
Total solution for fresh air with Daikin supply of both VAM and
electrical heaters
Total heat
exchanged
clean air
9 AM
12 PM
5 PM
Increase in air
volume and
better comfort
compared to fixed
ventilation rate
10
11
Morning meeting
12
13
Lunch time
14
15
16
Meeting
17
18
19
hour
CO2 level
Fixed ventilation rate
Ventilation amount
Using CO2 sensors has the most energy-saving potential in buildings where occupancy fluctuates during a 24-hour period, is unpredictable and peaks at a high level. For example
office buildings, government facilities, retail stores and shopping malls, movie theaters, auditoriums, schools, entertainment clubs and nightclubs. The ventilation unit's reaction to
fluctuations in CO2 can be easily adjusted by the customer.
186
INDOOR
30.6C
62% RH
32C
70% RH
SA
27.4C
63% RH
RA
26C
50% RH
Integrally-formed liner
SA
Integrallyformed liner
RA
Temperature
and humidity is
exhanged between
the layers
Ventilation
Power input - 50Hz
Temperature exchange
efficiency - 50Hz
Enthalpy exchange
efficiency - 50Hz
Ultra high
Ultra high
Ultra high/High/Low
Ultra high/High/Low
Operation mode
Heat exchange system
Heat exchange element
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Casing
Material
Heat exchange mode
Ultra high
Fan-Air flow rate 50Hz
Bypass mode
Ultra high
Fan-External static
Ultra high
pressure - 50Hz
High
Low
Air filter
Type
Ultra high
Sound pressure level Heat exchange mode
- 50Hz
Bypass mode
Ultra high
Operation range
Min.
Max.
Relative humidity
Refrigerant
Type / GWP
Connection duct diameter
Power supply
Phase/Frequency/Voltage
Current
Maximum fuse amps (MFA)
VAM
kW
kW
%
%
%
mm
kg
m/h
m/h
Pa
Pa
Pa
dBA
dBA
CDB
CDB
%
mm
Hz/V
A
150FA
0.116
0.116
250FA
0.141
0.141
350FB
0.132
0.132
74/74/79
72/72/77
75/75/80
58/58/64
64/64/69
58/58/62
64/64/68
500FB
0.178
0.178
650FB
0.196
0.196
74/74/77
800FB
0.373
0.373
1000FB
0.375
0.375
74/74/76
75/75/76.5
1500FB
0.828
0.828
2000FB
0.852
0.852
75/75/78
61/61/67
58/58/63
60/60/62
61/61/63
61/61/64
61/61/66
65/65/70
62/62/67
63/63/66
65/65/67
66/66/68
66/66/70
Heat exchange mode / Bypass mode / Fresh-up mode
Air to air cross flow total heat (sensible + latent heat) exchange
Specially processed non-flammable paper
364x1,004x1,156 726x1,512x868 726x1,512x1,156
285x776x525
301x828x816
364x1,004x868
24
33
52
55
64
131
152
Galvanised steel plate
150
250
350
500
650
800
1,000
1,500
2,000
150
250
350
500
650
800
1,000
1,500
2,000
69
64
98
93
137
157
137
39
20
Multidirectional fibrous fleeces
27 / 28.5
28 / 29
32
33
34.5
36
39.5
40
27 / 28.5
28 / 29
32
33.5
34.5
36
40.5
40
-15
50
80% or less
-/100
150
200
250
350
1~/50/60/220-240/220
15
16
187
RH: Relative Humidity SA: Supply Air (to room) RA: Return Air (from room)
VH
Total solution for fresh air with Daikin supply of both VAM
and electrical heaters
Increased comfort in low outdoor temperature thanks
to the heated outdoor air
Integrated electrical heater concept (no additional accessories
required)
Standard dual flow and temperature sensor
Flexible setting with adjustable setpoint
Increased safety with 2 cut-outs: manual & automatic
BMS integration thanks to:
- Volt free relay for error indication
- 0-10VDC input for setpoint control
VH
(VH)
220/250V ac 50/60 Hz. +/-10%
19A at 40C (ambient)
5k ohms at 25C (table 502 1T)
0 to 40C / (0-10V 0-100%)
20 x 5mm 250mA
Power ON - Yellow
Heater ON - Red (solid or flashing, indicating pulsed control)
Airflow fault - Red
Mounting holes
Maximum ambient adjacent to terminal box
Auto high temp. cutout
Man. reset high temp. cutout
Run relay
BMS setpoint input
VH
Capacity
Duct diameter
Connectable VAM
kW
mm
1B
1
100
VAM150FA
-
For the selection of the appropriate capacity, please refer to the VAM selection software.
188
2B
1
150
VAM250FA
VAM350FB
3B
1
200
VAM500FB
VAM650FB
4B
1.5
250
VAM800FB
VAM1000FB
4/AB
2.5
250
VAM800FB
VAM1000FB
5B
2.5
300
VAM1500FB
VAM2000FB
Switch box
Ceiling hook
4-14x40 oval hole
Inspection hole
450
285
600
Maintenance over
104
120.3
67
20
149
120~250
269
SA
104
124
288
560
EA
Exhaust air to outdoors
718
Sealing
20
120
164
509
RA
288
124 164
OA
Damper plate
149
(Maintenance cover)
Exhaust spacer
(Switch box)
145
760
97
200
145
Air filters
NOTE
Be sure to provide the inspection hole (450x450 mm) to inspect the air filters, the exchange elements and fans.
3TW27874-1
VAM250FA
VAM250FA
Maintenance space for the heat exchange elements, the air
filters and fans
Switch box
Ceiling hook
4-14x40 oval hole
Inspection hole
450
285
Maintenance over
120.3
67
20
104
600
120~250
269
149
SA
509
124
288
560
164
RA
OA
288
124 164
EA
Sealing
718
20
120
Damper plate
149
(Maintenance cover)
760
145
97
200
(Switch box)
145
Air filters
NOTE
Be sure to provide the inspection hole (450x450 mm) to inspect the air filters, the exchange elements and fans.
3TW27884-1
189
Ceiling hook
4 12 x 40 oval hole
Sealing
Damper plate
RA
Return air from room
EA
Exhaust air to outdoors
SA
Supply air to room
Supply air fan
OA
Fresh air from outdoors
(outdoor air)
Switch box
Inspection hole
Maintenance space for the heat exchange
element, the air lters and fans
Maintenance cover
Air lters
Switchbox
NOTES
3D081162
1. Be sure to provide the inspection hole to inspect the air lters, the exchange elements and fans.
VAM500FB
VAM500FB
Ceiling hook
4 12 x 40 oval hole
Sealing
Damper plate
RA
Return air from room
EA
Exhaust air to outdoors
SA
Supply air to room
OA
Fresh air from outdoors
(outdoor air)
Switch box
Inspection hole
Maintenance space for the heat exchange
element, the air lters and fans
Maintenance cover
Air lters
Switchbox
NOTES
1. Be sure to provide the inspection hole to inspectthe air lters, the exchange elements and fans.
190
3D081163
Ceiling hook
4 12 x 40 oval hole
Damper plate
Exhaust air fan
RA
Return air from room
EA
Exhaust air to outdoors
SA
Supply air to room
OA
Fresh air from outdoors
(outdoor air)
Maintenance cover
Air lters
Switchbox
NOTES
3D081164
1. Be sure to provide the inspection hole to inspect the air lters, the exchange elements and fans.
VAM800FB
VAM800FB
Sealing
Ceiling hook
4 12 x 40 oval hole
Damper plate
Exhaust air fan
RA
Return air from room
EA
Exhaust air to outdoors
SA
Supply air to room
OA
Fresh air from outdoors
(outdoor air)
Maintenance cover
Air lters
Switchbox
NOTES
1. Be sure to provide the inspection hole to inspect the air lters, the exchange elements and fans.
3D081165
191
Ceiling hook
4 12 x 40 oval hole
Damper plate
Exhaust air fan
RA
Return air from room
EA
Exhaust air to outdoors
SA
Supply air to room
OA
Fresh air from outdoors
(outdoor air)
Inspection hole
Maintenance cover
Air lters
Switchbox
NOTES
3D081166
1. Be sure to provide the inspection hole to inspect the air lters, the exchange elements and fans.
VAM1500FB
VAM1500FB
Sealing
Ceiling hook
4 14 x 40 oval hole
Exhaust air fan (2x)
Damper plate
EA
Exhaust air to outdoors
RA
Return air from room
OA
Fresh air from outdoors
(outdoor air)
SA
Supply air to room
Supply air fan (2x)
Switch box
Inspection hole
Maintenance cover
Air lters
Switchbox
NOTES
1. Be sure to provide the inspection hole to inspect the air lters, the exchange elements and fans.
192
3D081167
Sealing
Damper plate
RA
EA
Exhaust air to outdoors
SA
Supply air to room
OA
Fresh air from outdoors
(outdoor air)
Maintenance cover
Air lters
Switchbox
NOTES
3D081168
1. Be sure to provide the inspection hole to inspect the air lters, the exchange elements and fans.
VAM150FA
VAM150FA
50 Hz, 220-240V
60Hz, 220V
Exchange efciency
per
En
atu
tha
En
tha
lpy
lpy
re e
exc
xch
han
ge
ang
ee
fci
ef
cie
ncy
exc
han
ge
ef
cie
ncy
Ultra-High
(co
VAM150FA
Tem
enc
(he
atin
g)
olin
g)
(Pa)
High
100
Pipe length
4D036773
193
50 Hz, 220-240V
60Hz, 220V
Exchange efciency
VAM250FA
Tempe
ra
ture e
Entha
xchan
lpy ex
ge ef
ciency
chang
Enthalp
e efc
y exch
iency
ange e
fcienc
y
(heatin
g)
(coolin
g)
Ultra-High
(Pa)
High
Low
4D036774
VAM350FA
VAM350FB
pe
up
Fa
mi
pe
cto
Fa
r li
ry
se
tU
r li
H-
mi
sp
ee
ry
L speed
er
Airow (m3/h)
UH Speed
H Speed
L Speed
NOTES
1. The fan speeds are valid for 230V 50Hz power supply
194
Airow (m3/h)
-sp
ee
tU
d
Hsp
set
H-s eed
pe
lim
e
it U
d
H-s
low
pee
er l
imi
upp
d
tH
er li
-sp
mit
eed
Fac
L-s
tory
pee
set
d
lowe
L
s
r lim
pee
it L-s
d
peed
cto
low
Airow (m3/h)
tH
up
H speed
UH speed
Airow (m3/h)
3D082177
up
pe
Fa
up
pe
ry
r li
low
r li
cto
er
mi
mi
tU
H-
se
tU
tH
sp
-sp
H-
ee
lim
d
it U
pe Fact
Hr li or
sp
mi y s
t
ee
e
L-s t H
low
d
pe -s
er
ed pe
lim
ed
it H
Fac
-sp
tory
ee
set
d
low
L-s
er li
pee
mit
d
L-s
pee
d
up
ee
sp
Airow (m3/h)
ee
Airow (m3/h)
L speed
UH speed
Airow (m3/h)
UH Speed
H Speed
L Speed
Airow (m3/h)
NOTES
1. The fan speeds are valid for 230V 50Hz power supply
3D082178
VAM650FA
VAM650FB
H speed
pe
Fa
up
cto
pe
ry
r li
r li
se
mi
tU
H-
sp
ee
Airow (m3/h)
tU
up
Airow (m3/h)
H-
mi
sp
tH
low
ee
-sp
d
e
ee
Fa r limi
d
cto
tU
upp
ry
H
set
s
er l
H pee
imi
t L- -spe d
Fac lowe
r li
spe
e
tory
ed d
set mit H
L-s
pee speed
lowe
d
r lim
it Lspe
ed
Airow (m3/h)
UH Speed
H Speed
L Speed
NOTES
1. The fan speeds are valid for 230V 50Hz power supply
L speed
UH speed
Airow (m3/h)
3D082179
195
H speed
pe
cto
up
pe
ry
-sp
ee
lim
low
er
-sp
lim
ry
it L
-sp
ee
tL
-sp
ee
Airow (m3/h)
Airow (m3/h)
L speed
ee
it U
H-
se
sp
ee
-sp
lim
cto
tH
ee
Fa
H-
-sp
ee
se
er
tU
tH
sp
d low
it H
mi
mi
H-
ry
r li
r li
tU
cto
it L
er
pe
Fa
r lim
low
se
up
sp
ee
up
Fa
ee
Airow (m3/h)
UH Speed
H Speed
L Speed
Airow (m3/h)
NOTES
1. The fan speeds are valid for 230V 50Hz power supply
3D082180
VAM1000FB
VAM1000FB
H speed
pe
ry
up
up
se
tU
pe
H-
r li
lo
we
er
lim
it L
it
ee
it
-s
pe
ed
pe
ed
Airow (m3/h)
-s
ee
H-
sp
pe
ed
ee
d
pee
1. The fan speeds are valid for 230V 50Hz power supply
H-s
NOTES
set
UH Speed
H Speed
L Speed
tory
Fac
Airow (m3/h)
196
Airow (m3/h)
L speed
UH
-sp
im
-sp
im
tL
rl
UH
rl
se
-s
ee
we
ry
it
it H
-sp
lo
im
im
ee
tL
cto
rl
sp
mi
Fa
low
pe
rl
cto
up
Fa
UH speed
Airow (m3/h)
3D082181
ed
d
ee
sp
pe
H-
ed
pe
-s
L speed
tU
se
-s
-s
ed
lim
it L
it
pe
UH
lim
-s
Airow (m3/h)
it
tL
im
se
Airow (m3/h)
ry
cto
Fa
er
rl
er
ry
ee
ee
ee
cto
low
-sp
lo
sp
ed
pe
-s
tL
H-
we
Fa
mi
-sp
it
UH
r li
tH
im
it
pe
se
rl
lim
up
ry
r
pe
up
pe
cto
lo
up
Fa
UH speed
pe
ed
Airow (m3/h)
UH Speed
H Speed
L Speed
Airow (m3/h)
NOTES
1. The fan speeds are valid for 230V 50Hz power supply
3D082182
VAM2000FB
VAM2000FB
H speed
or
ct
Fa
ed
pe
-s
d
d
UH
ee
ee
p
it
sp
-s
im
HH
rl
it ed
tU
pe
im pe
se
r l -s
pe H
up it U
lim
up
UH speed
er
ct
or
lo y s
w et
er
H
rl
lim -s
im
it pee
it
Fa
L
cto
-s H-s d
pe
p
ry
ed ee
se
low
d
tL
er
-s
lim
pe
it L
ed
-s
pe
ed
up
pe
Airow (m3/h)
UH Speed
H Speed
L Speed
NOTES
1. The fan speeds are valid for 230V 50Hz power supply
Airow (m3/h)
Airow (m3/h)
L speed
lo
Fa
Airow (m3/h)
3D082183
197
VKM-GB/VKM-GBM
moisture recovery
air flow rate, so less need for dampers compared with traditional
installation.
Specially developed heat exchange element with High
Efficiency Paper (HEP)
Can operate in over- and under pressure
Exhaust Fan
EA
Heat Exchanger
Elements
Damper Motor
Damper
RA
(Return air from room)
Float switch
Humidifier element:
Utilizing the principle of capillary action, water is
permeated throughout the humidifier element.
The heated air from the DX coil passes through the
humidifier and absorbs the moisture.
water
AIRFLOW
Drain pan
1
VKM-GM example
198
Solenoid
valve
Drain
SA
VKM-GM example
Cooling
Heating
Operation mode
Heat exchange system
Heat exchange element
Humidifier
System
Dimensions
Unit
Weight
Unit
Casing
Material
Heat exchange mode
Fan-Air flow rate 50Hz
Bypass mode
Fan-External static
Ultra high
pressure - 50Hz
High
Low
Air filter
Type
Sound pressure level Heat exchange mode
- 50Hz
Bypass mode
Operation range
Around unit
Supply air
Return air
On coil
temperature
Ultra high
Ultra high
Ultra high/High/Low
Ultra high/High/Low
HeightxWidthxDepth
Ultra high
Ultra high
Ultra high
Ultra high
Cooling
Heating
Refrigerant
Type / GWP
Connection duct diameter
Piping connections
Liquid
OD
Gas
OD
Water supply
Drain
Power supply
Phase/Frequency/Voltage
Current
Maximum fuse amps (MFA)
Max.
Min.
VKM
kW
kW
kW
kW
%
%
%
76/76/77.5
64/64/67
67/67/69
mm
kg
387x1,764x832
94
m/h
m/h
Pa
Pa
Pa
500
500
dBA
dBA
CDB
CDB
CDB
CDB
CDB
39
40
mm
mm
mm
mm
200
Hz/V
A
78/78/79
210
170
140
74/74/76.5
78/78/79
74/74/76.5
66/66/68
62/62/66
64/64/67
66/66/68
62/62/66
71/71/73
65/65/69
67/67/69
71/71/73
65/65/69
Heat exchange mode / Bypass mode / Fresh-up mode
Air to air cross flow total heat (sensible + latent heat) exchange
Specially processed non-flammable paper
Natural evaporating type
387x1,764x1,214
387x1,764x832
387x1,764x1,214
110
112
100
119
123
Galvanised steel plate
750
950
500
750
950
750
950
500
750
950
150
200
205
110
160
100
150
155
70
110
70
120
105
60
Multidirectional fibrous fleeces
41.5
41
38
40
41.5
41
39
41
0C~40CDB, 80% RH or less
-15C~40CDB, 80% RH or less
0C~40CDB, 80% RH or less
-15
43
R-410A / 2.087,5
250
200
250
6.35
12.7
6.4
PT3/4 external thread
1~/50/220-240
15
199
Ventilation
Power input - 50Hz
Heat insulator
(locally procured)
EA
(Exhaust air to outdoors)
Branch duct
(locally procured)
Control box
Maintenance space for the heat exchanger
elements the air filters and fans
Inspection
hatch
Inspection
hatch
Flexible duct
(locally procured)
Heat insulator
(locally procured)
A gradient of
more than 1/30
200
Nominal diameter
(locally procured)
OA
(Fresh air from outdoors)
EA
(Exhaust air to outdoors)
Sloping downwards at a
gradient of the 1/100
Inspection hatch
(locally procured)
Suspention bolt
(locally procured)
RA
(Return air from room)
SA
(Return air to room)
NOTES
1. L eave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters, heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
7. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
8. Do not place something which shouldnt get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air
filter is very dirty.
3D083014
200
Heat insulator
(locally procured)
EA
(Exhaust air to outdoors)
Round shape hood
(Locally procured)
OA
(Fresh air from outdoors)
Control box
Inspection
hatch
Inspection
hatch
Branch duct
(locally procured)
Flexible duct
(locally procured)
Heat insulator
(locally procured)
200
Nominal diameter
Drain valve
(locally procured)
Strainer
(accessory)
(locally procured)
OA
(Fresh air from outdoors)
Sloping downwards at a
gradient of the 1/100
450 600
Inspection hatch
(locally procured)
Suspension bolt
(locally procured)
RA
(Return air from room)
SA
(Return air to room)
NOTES
1. L eave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters, heat exchange elements, fans, and humidifier
elements can easily be inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water. Also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Use city water or clean water.
Include water supply piping with straner, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the
inspection.
5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping.
6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2).
7. Make sure the supply water is between 5 C and 40 C in temperature.
8. Insulate the water supply piping to prevent condensation from forming.
9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
11. Install in a location where the air around the unit or taken into the humidifier will not drop below 0 C.
12. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
13. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
14. Do not place something which shouldnt get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air
filter is very dirty.
15. Feed clean water. If the supply water is hard water, use a water softener because of short life.
Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the
supply water conditions of hardness: 400 mg/L.)
3D083011
201
EA
(Exhaust air to outdoors)
Heat insulator
(locally procured)
EA
(Exhaust air to outdoors)
Branch duct
(locally procured)
Inspection
hatch
Inspection
hatch
Silencer
(locally procured)
Control box
Heat insulator
(locally procured)
Flexible duct
(locally procured)
200
Nominal diameter
A gradient of
more than 1/30
(locally procured)
OA
(Fresh air from outdoors)
EA
(Exhaust air to outdoors)
Sloping downwards at a
gradient of the 1/100
450 600
Inspection hatch
(locally procured)
Suspention bolt
(locally procured)
RA
(Return air from room)
SA
(Return air to room)
NOTES
1. L eave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters, heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
7. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
8. Do not place something which shouldnt get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air
filter is very dirty.
3D083015
202
Heat insulator
(locally procured)
EA
(Exhaust air to outdoors)
Branch duct
(locally procured)
Control box
Inspection
hatch
Inspection
hatch
Heat insulator
(locally procured)
Silencer
(locally procured)
Flexible duct
(locally procured)
250
Nominal diameter
Drain valve
(locally procured)
Strainer
(accessory)
(locally procured)
OA
(Fresh air from outdoors)
Sloping downwards at a
gradient of the 1/100
450 600
Inspection hatch
(locally procured)
Suspension bolt
(locally procured)
RA
(Return air from room)
SA
(Return air to room)
NOTES
1. L eave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters, heat exchange elements, fans, and humidifier
elements can easily be inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water. Also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Use city water or clean water.
Include water supply piping with straner, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the
inspection.
5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping.
6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2).
7. Make sure the supply water is between 5 C and 40 C in temperature.
8. Insulate the water supply piping to prevent condensation from forming.
9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
11. Install in a location where the air around the unit or taken into the humidifier will not drop below 0 C.
12. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
13. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
14. Do not place something which shouldnt get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air
filter is very dirty.
15. Feed clean water. If the supply water is hard water, use a water softener because of short life.
Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the
supply water conditions of hardness: 400 mg/L.)
3D083012
203
EA
(Exhaust air to outdoors)
Heat insulator
(locally procured)
EA
(Exhaust air to outdoors)
Branch duct
(locally procured)
Inspection
hatch
Inspection
hatch
Silencer
(locally procured)
Control box
Heat insulator
(locally procured)
Flexible duct
(locally procured)
A gradient of
more than 1/30
250
Nominal diameter
(locally procured)
OA
(Fresh air from outdoors)
EA
(Exhaust air to outdoors)
Sloping downwards at a
gradient of the 1/100
450 600
Inspection hatch
(locally procured)
Suspention bolt
(locally procured)
RA
(Return air from room)
SA
(Return air to room)
NOTES
1. L eave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters, heat exchange elements, and fans can easily be
inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
7. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
8. Do not place something which shouldnt get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air
filter is very dirty.
3D083016
204
Heat insulator
(locally procured)
EA
(Exhaust air to outdoors)
Branch duct
(locally procured)
Control box
Inspection
hatch
Inspection
hatch
OA
(Fresh air from outdoors)
Heat insulator
(locally procured)
Silencer
(locally procured)
Flexible duct
(locally procured)
250
Nominal diameter
Drain valve
(locally procured)
Strainer
(accessory)
(locally procured)
OA
(Fresh air from outdoors)
Sloping downwards at a
gradient of the 1/100
450 600
Inspection hatch
(locally procured)
Suspension bolt
(locally procured)
RA
(Return air from room)
SA
(Return air to room)
NOTES
1. L eave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters, heat exchange elements, fans, and humidifier
elements can easily be inspected and serviced.)
2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water. Also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to
prevent dew condensation. (Material: glass wool of 25mm thick)
3. Do not turn the unit upside down.
4. Use city water or clean water.
Include water supply piping with straner, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the
inspection.
5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping.
6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2).
7. Make sure the supply water is between 5 C and 40 C in temperature.
8. Insulate the water supply piping to prevent condensation from forming.
9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation.
10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming.
11. Install in a location where the air around the unit or taken into the humidifier will not drop below 0 C.
12. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory).
13. In areas where freezing may occur, always take steps to prevent the pipes from freezing.
14. Do not place something which shouldnt get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air
filter is very dirty.
15. Feed clean water. If the supply water is hard water, use a water softener because of short life.
Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the
supply water conditions of hardness: 400 mg/L.)
3D083013
205
EA
(Exhaust air to outdoors)
50Hz, 220V-240V
Operating air flow rate range
Temp
e
rature
Enth
alpy
Enth
exch
exch
nge e
fficien
effic
ange
cy
ienc
y (he
effic
ating
ienc
y (co
oling
Ultra High
200
Pipe
length
External static pressure (Pa)
alpy
ange
excha
Exchange
efficiency
(%)
High
Low
2) Rated point:
3) The characteristic of each tap becomes a setup of the
characteristic of the same code number.
3D082904
VKM50GBM
VKM50GBM
Exchange efficiency
(%)
Operating air flow rate range
50Hz, 220V-240V
Temp
e
rature
Enth
alpy
Enth
exch
exch
nge e
effic
ange
fficien
ienc
cy
y (he
effic
ating
ienc
y (co
oling
Ultra High
200
Pipe
length
alpy
ange
VKM50GBM
excha
High
Low
206
2) Rated point:
3) The characteristic of each tap becomes a setup of the characteristic of the
same code number.
3D082901
50Hz, 220V-240V
Exchange
efficiency
(%)
eratu
re ex
Enth
alpy
Enth
alpy
chan
ge e
exch
ange
exch
ange
fficie
ncy
effic
ienc
y (he
effic
ating
ienc
y (co
oling
Ultra High
High
250
Pipe
length
Tem
p
Low
3D082905
VKM80GBM
VKM80GBM
Exchange efficiency
(%)
50Hz, 220V-240V
Operating air flow
rate range
Tempera
ture exch
alpy
Enth
alpy
ange effic
exch
ange
exch
iency
effic
ange
ienc
y (he
effic
ating
ienc
y (co
oling
Ultra High
250
Pipe
length
Enth
VKM80GBM
High
Low
2) Rated point:
3) The characteristic of each tap becomes a setup of the characteristic of the
same code number.
3D082902
207
50Hz, 220V-240V
Exchange
efficiency
(%)
Operating air flow rate range
Operating air flow rate range
erat
Ent
ure
halp
y ex
Ent
halp
cha
y ex
exc
han
nge
cha
nge
ge e
fficie
effic
ienc
ncy
y (h
effic
ienc
eatin
y (c
g)
ooli
ng)
Tem
p
250
Pipe
length
Ultra High
High
Low
3D082906
VKM100GBM
VKM100GBM
Exchange efficiency
(%)
50Hz, 220V-240V
En
era
tha
lpy
En
VKM100GBM
tha
lpy
ture
exc
han
exc
ge
han
ge
exc
han
effi
ge e
ncy
cie
fficie
cie
effi
ncy
(he
ncy
atin
(co
g)
olin
g)
Ultra High
High
250
Pipe
length
Tem
p
Low
208
2) Rated point:
3) The characteristic of each tap becomes a setup of the characteristic of the
same code number.
3D082903
Professional
Pre-configured sizes
Tailored to the individual
Professional
140
customer
Modular construction
120
Energy
Energy
100
energy consumption
90
80
NEW Compact
Pre-configured sizes
Plug & Play concept
EC Fan Technology
High Efficiency Heat Wheel
Compact Design
70
60
50
40
Compact
20
750 m3/h
up to 144,000 m3/h
750 m3/h
up to 100,000 m3/h
500m3/h
up to 25,000 m3/h
Return on investment
The air handling unit (AHU) is critical to an effective
climate control system and the savings generated
by our advanced designs and operating efficiencies
guarantee a rapid return on the investment made.
Our AHU Energy series has been designed to deliver
exceptional performance thus driving down
the energy consumed and so lowering energy bills.
Taken over the expected 15-year life-span
of the equipment, this will result in a substantial
saving, especially in a time of ever increasing
energy prices.
Pre-defined sizes
209
210
Expansion valve
Electronic interface
(EKEXV)
(EKEQ)
Ts
DDC
Te
Td
AHU
Daikin
control box:
EKEQFCBA
Tr
DDC
Room
Te
Td
AHU
Daikin
control box:
EKEQFCBA
Tr
Room
Control your AHU just like a VRV indoor unit with 100% fresh air
(BRC1D52 or BRC1E52A/B - optional)
Set point can be fixed via standard Daikin infrared remote control.
Remote ON/OFF can be achieved
by an optional adapter KRP4A51.
No external DDC controller should be connected. The cooling load is
determined from the air suction temperature and set point on
the Daikin controller.
ON / OFF
Daikin
control box:
EKEQFCBA
AHU
Te
Ts
Tr
KRP4A51
Ts
Td
Daikin
control box:
EKEQDCB
EKEQMCB
Room
BRC1D52
BRC1E52A/B
Option kit
Possibility w
Possibility x
EKEQFCBA
Possibility y
Possibility z
EKEQDCB
EKFQMCBA*
Te
AHU
Tr
Td
Room
BRC1D52
BRC1E52A/B
Tr = Room temperature
Te = Evaporating temperature
Features
DDC controller is required
temperature control using air suction or air discharge temperature
DDC and Microtech controller is required
Precise Temperature control using air suction or air discharge temperature
Using fixed evaporating temperature, no set point can be set using remote control
Using Daikin infrared remote control BRC1D52 or BRC1E52A/B
Temperature control using air suction temperature
211
212
R*YQ8-20T
R*YQ12-54T
Refrigerant piping
F1-F2
other communication
213
F1 - F2
Refrigerant piping
Ventilation
ERQ
Capacity range
HP
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
EER
COP
Dimensions
Unit
mm
Weight
Unit
kg
Fan-Air flow rate Cooling
Nom.
m/min
Heating
Nom.
m/min
Sound power level Cooling
Nom.
dBA
Sound pressure Cooling
Nom.
dBA
Heating
Nom.
dBA
level
Operation range Cooling
Min./Max.
CDB
Heating
Min./Max.
CWB
On coil
Heating Min.
CDB
CDB
temperature Cooling Max.
Refrigerant
Type / GWP
Charge
kg/ TCO2Eq
Piping
Liquid
OD
mm
Gas
OD
mm
connections
Drain
OD
mm
Power supply
Phase/Frequency/Voltage
Hz/V
Current
Maximum fuse amps (MFA)
A
100AV1
4
11.2
12.5
2.81
2.74
Ventilation
ERQ
Capacity range
HP
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
EER
COP
Dimensions
Unit
mm
Weight
Unit
kg
Fan-Air flow rate Cooling
Nom.
m/min
Heating
Nom.
m/min
Sound power level Nom.
dBA
Sound pressure level Nom.
dBA
Operation range Cooling
Min./Max.
CDB
Heating
Min./Max.
CWB
On coil
Heating Min.
CDB
CDB
temperature Cooling Max.
Refrigerant
Type / GWP
Charge
kg/ TCO2Eq
Piping
Liquid
OD
mm
Gas
OD
mm
connections
Power supply
Phase/Frequency/Voltage
Hz/V
Current
Maximum fuse amps (MFA)
A
125AW1
5
14.0
16.0
3.52
4.00
3.98
4.00
1,680x635x765
159
95
95
72
54
214
125AV1
5
14.0
16.0
3.51
3.86
140AV1
6
15.5
18.0
4.53
4.57
3.42
3.94
3.99
4.56
4.15
1,345x900x320
120
106
102
66
50
52
105
67
51
53
-5/46
-20/15.5
10
35
R-410A / 2.087,5
4.0/8.4
9.52
69
53
55
15.9
19.1
26x3
1N~/50/220-240
32.0
6.2/12.9
15.9
16
200AW1
8
22.4
25.0
5.22
5.56
4.29
4.50
250AW1
10
28.0
31.5
7.42
7.70
3.77
4.09
1,680x930x765
187
171
171
240
185
185
78
57
-5/43
-20/15
10
35
R-410A / 2.087,5
7.7/16.1
9.52
19.1
3N~/50/400
58
8.4/17.5
22.2
25
ERQ100
1-phase ERQ125
ERQ140
System A
ERQ125
3-phase ERQ200
ERQ250
System B
VRV III
System B
VRV IV
EKEQDCBV3 EKEQFCBAV3 EKEQMCBAV3 EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500
Z control W,X,Y control Z control
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
n1
n1
n1
n1
n1
n1
n1
n1
n1
n1
n1
1 -> 3
n2
n2
n2
n2
n2
n2
n2
n2
n2
n2
n2
P (pair application): combination depends on the capacity of the air handling unit
n1 (multi application: combination of air handling units and VRV DX indoor units): to determine the quantity, refer to the engineering data book
n2 (multi application: multiple air handling units, or the combination of air handling units and VRV DX indoor units): to determine the quantity, refer to the engineering data book
Control box EKEQFA can be connected to some types of VRV IV outdoor units (with a maximum of 3 boxes per unit). Do not combine EKEQFA control boxes with VRV DX indoor units, RA indoor units or hydroboxes
Capacity table
Cooling
Heating
Allowed heat exchanger capacity (kW)
Minimum
5,0
6,3
7,9
10,0
12,4
15,5
17,7
24,7
35,4
49,6
50
63
80
100
125
140
200
250
400
500
EKEXV Class
Maximum
6,2
7,8
9,9
12,3
15,4
17,6
24,6
30,8
49,5
61,6
Minimum
5,6
7,1
8,9
11,2
13,9
17,4
19,9
27,8
39,8
55,1
50
63
80
100
125
140
200
250
400
500
Maximum
7,0
8,8
11,1
13,8
17,3
19,8
27,7
34,7
55,0
69,3
EKEXV
mm
kg
dBA
CDB
CDB
mm
50
63
6.35
80
100
125
140
401x215x78
2.9
45
10 (1)
35 (2)
R-410A / 2.087,5
9.52
200
250
400
500
12.7
15.9
(1) The temperature of the air entering the coil in heating mode can be reduced to -5CDB. Contact your local dealer for more information. (2) 45% Relative humidity.
EKEQ
Unit
Unit
Phase/Frequency/Voltage
mm
kg
Hz/V
FCBA
See note
ERQ / VRV
DCB
Pair
ERQ
132x400x200
3.9
MCBA
Multi
VRV
3.6
1~/50/230
The combination of EKEQFCBA and ERQ is in pair application. The EKEQFCBA can be connected to some type of VRV IV outdoor units with a maximum of 3 control boxes. The combination with DX indoor units,
hydroboxes, RA outdoor units, ... is not allowed. Refer to the combination table drawing of the outdoor unit for details.
215
EKEXV Class
Controllers
INTELLIGENT
TOUCH MANAGER
DCM601A51
INFRARED REMOTE
CONTROLLER
216
Control Systems
Control Systems
218
220
226
229
230
231
232
Control Systems
217
Shop
Unit control
Integrating control
BRC1E52A/B
RTD-20
1 remote
controller for
1 indoor unit
(group)
1 gateway for
1 indoor unit
(group)
RTD-Net
KLIC-DI
Advanced control
EKMBDXA
DCS601C51
DCM601A51
1 gateway for
max. 64 indoor
unit(s) (groups)
& 10 outdoors
1 iTC for 64
indoor unit(s)
(groups)
1 iTM for 64
indoor unit(s)
(groups) (1)
(1) : 7 iTM plus adapters (DCM601A52) can be added to have 512 indoor groups and 80 outdoor (systems)
Hotel
Hotel guest can control & monitor basic functionalities from his room
Limited control possibilities for hotel guests
Interlock with window contact
Interlock with key-card
Unit control
Advanced control
RTD-HO
RTD-Net
KLIC-DI
DCS601C51
DCM601A51
1 remote
controller for
1 indoor unit
(group)
1 gateway for
1 indoor unit
(group)
1 gateway for
1 indoor unit
(group)
1 gateway for 1
indoor unit
1 iTC for 64
indoor unit(s)
(groups)
1 iTM for 64
indoor unit(s)
(groups) (1)
218
Integrating control
BRC2/3E52C
Office
Unit control
BRC1E52A/B
1 remote
controller for
1 indoor unit
(group)
Integrating control
EKMBDXA
DMS504B51
Advanced control
DMS502A51 /
DAM412B51
DCS302C51 /
DST301B51
1 gateway for
1 gateway for
1 R/C for max.
1 gateway for
max. 64 indoor
128 indoor
64 groups, 128
64 indoor unit(s)
unit(s) (groups)
unit(s) (groups), indoor units, 10
(groups)
& 10 outdoors
20 outdoors (2)
outdoors
(3)
DCS601C51
DCM601A51
1 iTC for 64
indoor unit(s)
(groups)
1 iTM for 64
indoor unit(s)
(groups) (1)
Technical cooling
Unit
Integrating
Advanced
DTA113B51
RTD-10
DCM601A51
1 PCB for 4
indoor unit(s)
(groups)
1 gateway for
up to 8 indoor
units (group)
1 iTM for 64
indoor unit(s)
(groups) (1)
Control Systems
(1) : 7 iTM plus adapters (DCM601A52) can be added to have 512 indoor groups and 80 outdoor (systems)
(2) : extension needed to go to 256 indoor unit(s) (groups), 40 outdoors
(3) : ON/OFF only
(1) : 7 iTM plus adapters (DCM601A52) can be added to have 512 indoor groups and 80 outdoor (systems)
219
BRC1D52
BRC944B2
Display
Operating mode1
Heat Recovery Ventilation (HRV) in operation
Cool / heat changeover control
Centralised control indication
Group control indication
Set temperature1
Air flow direction1
Programmed time
Inspection test / operation
Fan speed1
Clean air filter
Defrost / hot start
Malfunction
1
ARC4*/BRC4*/BRC7*
ARC466A1
BRC4*/BRC7*
BRC2E52A / BRC3E52A
220
electricity consumption
(Function available in
combination with FCQG and
FCGHQ)
Other functions
Up to 3 independent schedules can be set,
so the user can easily change the schedule himself
throughout the year (e.g. Summer, winter, mid-season)
Possibility to individually restrict menu functions
Easy to use: all main functions directly accessible
Easy setup: clear graphical user interface for
advanced menu settings
Real time clock with auto update to daylight
saving time
Built-in backup power: when a power failure occurs
all settings remain stored up to 48 hours
Supports multiple languages
English, German, Dutch, Spanish, Italian, Portuguese,
French, Greek, Russian, Turkish, Polish (BRC1E52A)
English, German, Czech, Croatian, Hungarian,
Romanian, Slovenian, Bulgarian, Slovak, Serbian,
Albanian (BRC1E52B)
221
Control Systems
Centralised control of the Sky Air and VRV system can be achieved via 3 user friendly compact.
These controls may be used independently or in combination with 1 group = several (up to 16)
indoor units in combination and 1 zone = several groups in combination.
A centralised remote control is ideal for use in tenanted commercial buildings subject to random occupation,
enabling indoor units to be classified in groups per tenant (zoning).
The schedule timer programmes the schedule and operation conditions for each tenant and the control can
easily be reset according to varying requirements.
DCS302C51
DCS301B51
DST301B51
Schedule timer
Enabling 64 groups to be programmed.
a maximum of 128 indoor units can be controlled
8 types of weekly schedule
a maximum of 48 hours back up power supply
a maximum wiring length of 1,000m (total: 2,000m)
222
DTA113B51
Basic solution for control of Sky Air and VRV
Rotation function
Backup operation function.
BRC1D52
Up to 4 units / 1 adapter
DCS601C51
Detailed & easy monitoring and operation of VRV systems (max. 64 indoor units groups).
Public line
Fire alarm
Onboard
modem
Ethernet
Forced OFF contact input
Air conditioning
Network Service
System
DIII-NET
Indoor units
HRV
DCS601C51
System layout
Up to 64 indoor units can be
controlled
Management
Enhanced history function
Control
Individual control
Monitoring
Visualisation via Graphical
function
Open interface
Communication to any third
Connectable to
VRV
HRV
Sky Air
Split (via interface adapter)
installation space
223
Control Systems
Languages
English
French
German
Italian
Spanish
Dutch
Portuguese
NEW
Check on
https://www.youtube.com/
DaikinEurope
DCM601A51
Mini BMS
Internet
Extranet
LAN
3G
http interface
Integration of third
party equiqment
Max. 7
adapters
Di/Pi line
Fire alarm
Max. 200m
DCM601A52
Di/Pi port
kWh meter
indoor units,
air curtain,
Lighting
Fan
Pump
Sensor
Elevator
224
Alarm
I/O module
I/O module
hydrobox,
air handling units
Referigeration
WAGO
interface
BACnet
protocol
Split
User friendliness
Flexibility
NEW Cross-pillar integration (heating, air conditioning,
applied systems, refrigeration, air handling units)
NEW BACnet protocol for 3rd party products integration
I/O for integration of equipment such as lights,
pumps on WAGO modules
Modular concept for small to large applications
Control up to 512 indoor unit groups via one ITM
and combine multiple ITM via the web interface
Split
Fan coils
Refrigeration
Flexibility in size
From 64 up to number
of groups
Functions overview
Management
Control
English
Web access
Individual control
French
Power Proportional
German
Italian
Spanish
Dutch
Portuguese
Distribution (option)
Operational history
(malfunctions, operation hours, )
NEW
- Daikin AHU
- Fan coils
seasonal schedule)
Setpoint limitation
- Air curtains
according to plan
Temperature limit
waste
NEW
be controlled
Setback function
WAGO Interface
Sliding temperature
(2,560 groups)
Interlock control
System layout
Ethernet TCPIP
Connectable to
- BACnet protocol
party equipment
- WAGO coupler (interface
between WAGO and Modbus)
- Di module
- Do module
- Ai module
- Thermistor module
225
Control Systems
Languages
Modbus Interface
RTD
RTD-RA
RTD-NET
RTD-10
RTD-20
RTD-HO
226
Overview functions
Main functions
Dimensions
HxWxD
mm
Key card + window contact
Set back function
Prohibit or restrict remote control functions (setpoint limitation, ...)
Modbus (RS485)
Group control
0 - 10 V control
Resistance control
IT application
Heating interlock
Output signal (on/defrost, error)
Retail application
Partitioned room control
Air curtain
RTD-RA
RTD-NET
RTD-10
(1)
80 x 80 x 37,5
100 x100 x 22
RTD-20
**
***
***
****
RTD-NET
RTD-10
RTD-20
RTD-HO
Monitoring functions
On/Off
Set point
Mode
fan
Louver
RC temperature
RC mode
nbr units
Fault
Fault code
Return air temperature (Average /Min/Max)
Filter alarm
Termo on
Defrost
Coil In/Out temperature
RTD-RA
M,C
M
M
M
M
M
M
M
M
M
M
M
M
M
M,V,R
M,V,R
M,V,R
M,V,R
M,V,R
M,V,R
M,V,R
M
M
M
M
M
M
M
RTD-HO
M*
M*
M*
M*
M*
M*
RTD-RA
RTD-NET
RTD-10
RTD-20
RTD-HO
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
Control Systems
Control functions
On/Off
Set point
Mode
fan
Louver
HRV Damper control
Prohibit/Restrict functions
Forced thermo off
227
VRV network
DIII- NET
EKMBDXA
HRV
*via EKEQ box
Building
control
network
Fire alarm
Security
Lighting
Pump
EKMBDXA7V1
Maximum number of connectable indoor units
Maximum number of connectable outdoor units
Communication
DIII-NET - Remark
Protocol - Remark
Protocol - Type
Protocol - Max. Wiring
length
Dimensions
HeightxWidthxDepth
Weight
Ambient temperature - operation
Max.
Min.
Installation
Power supply
Frequency
Voltage
228
64
10
DIII-NET (F1F2)
2 wire; communication speed: 9600 bps or 19200 bps
RS485 (modbus)
m
mm
kg
C
C
Hz
V
500
124x379x87
2.1
60
0
Indoor installation
50
220-240
Elevator
KNX interface
KLIC-DD
KLIC-DI
Concept
light
house
shutter control
Domotica
Controller
tv
Concept
light
shop
shutter control
Domotica
tv
Controller
Sky Air
Control Systems
3 or 5 + auto
Stop or movement
2 or 3
Stop or movement
2 or 3
Swing or fixed positions (5)
229
BACnet Interface
Integrated control system for seamless connection between VRV,
applied systems, air handling units and BMS systems
BMS
VRV network
BACNET / ETHERNET
DIII- NET
DMS502A51
Local Control
VRV Outdoor unit
HRV
up to 256 units connectable per interface
Remote Control
EKACBACMSTP
Serial sequencing
panel
EKCM200J
EKCM200J
EKCM200J
EKDSSP-S
EKCMBACIP
EKCMBACMSTP
Fire alarm
Security
Pump
Lighting
Building
control
network
230
Elevator
LonWorks Interface
Open network integration of VRV and applied systems
monitoring and control functions into LonWorks networks
LON BMS
VRV network
adapter
LonTalk
DIII- NET
ETHERNET (TCP/IP)
DMS504B51
Local Control
VRV
Outdoor
unit
HRV
Remote Control
LonTalk
EKACLONP
Serial sequencing
panel
EKCM200J
EKCM200J
EKCM200J
EKDSSP-S
adapter
LonTalk
LonPoint
LonPoint
Security
Fire alarm
Control Systems
Building
control
network
System
231
Simplified commissioning
232
Simplified
Retrieve initial
commissioning
system settings
233
Control Systems
What is I-Net?
I-Net
performance monitoring
and analysis
24/7
I-Net Services
234
VRV Cloud
The VRV Cloud puts you in the driving seat of your
energy management. The easy-to-use energy data
trending and analytic tools puts you in control and
shows you CO2 footprint reduction opportunities
and energy savings of up to 15%.
Saving starts by measuring. Enhance your companys
sustainability !
Data server
Performance supervision
Internet
and analysis
24/7
Prediction analysis
Data trend logging
Information to:
customers
service company
CLOUD
Controller
Performance monitoring
Daikins unique I-Net Service aims to prevent
the equipment coming to an unexpected stop or
needing emergency repair.
Analysis
Control Systems
235
Room sensors
Rf Receiver
RF sender
Specifications
Dimensions
Weight
Power supply
Battery life
Battery type
Maximum range
Operation range
Communication
mm
g
m
C
Type
Frequency
MHz
Room temperature is sent to the indoor unit every 90 seconds or if the temperature difference is 0.2C or larger.
Specifications
Dimensions (HxW)
Weight
Length of branch wiring
236
mm
g
m
60 x 50
300
12
ADAPTER PCBs
Simple solutions for unique requirements
Daikins adapter PCBs provide simple solutions
for unique requirements. They are a low cost option
to satisfy simple control requirements and can be
used on single or multiple units.
(E)KRP1B*
adapter for wiring
KRP2A*/KRP4A*
Wiring adapter for
electrical appendices
Remotely start and stop up to 16 indoor units (1 group) (KRP2A* via P1 P2)
Remotely start and stop up to 128 indoor units (64 groups) (KRP4A* via F1 F2)
Alarm indication/ fire shut down
Remote temperature setpoint adjustment
DTA104A*
Outdoor Unit External
Control Adapter
KRP928*
Control Systems
237
AUTO-CLEANING PANEL
FILTERS
INTELLIGENT SENSORS
238
Options &
accessories
240
242
246
248
251
VRV outdoor
VRV indoor
Stylish indoor
Ventilation & Hot Water
Control Systems
239
outdoor
VRV IV with continuous heating
2-module
systems
VRV IV without
EKBPH012T +
EKBPHPCBT
EKBPH020T +
EKBPHPCBT
EKBPH012T +
EKBPHPCBT
EKBPH020T +
EKBPHPCBT
3-module
RXYQ8-12T RXYQ14-20T
systems
BHFQ22P1007 BHFQ22P1517
EKBPH012T
+ EKBPHPCBT
EKBPH020T
+ EKBPHPCBT
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
1 kit
per system
1 kit
per system
KKSA26A560* - Cool/heat selector PCB mounting plate (only required when cool/heat
selector PCB and Heater tape kit are combined)
KKSB2B61* - Demand PCB mounted plate. Needed to mount Demand PCB for some outdoor units.
RQYQ 140
RXYQQ8-12T
RXYQQ14-20T
BHFQ22P1007
BHFQ22P1517
KWC26B160
EKBPH012T +
EKBPHPCBT
EKBPH020T +
EKBPHPCBT
DTA104A53/61/62
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
KKSA26A560* - Cool/heat selector PCB mounting plate (only required when cool/heat
selector PCB and Heater tape kit are combined)
KKSB2B61* - Demand PCB mounted plate. Needed to mount Demand PCB for some
outdoor units.
Heat Pump
systems (2-pipe)
Refnet Joints
240
Metric-size connections
Imperial-size connections
Sound reduction kit (sound insulation)
Mechanical cool/heat selector allows to switch an entire Heat Pump system, or
one BS-box of a Heat Recovery system between cooling, heating and fan only.
Connects to the A-B-C terminals of the outdoor unit / BS-box.
Installation box for remote cool/heat selector KRC19-26
Closed pipe kit
Joint kit
Quiet kit
Metric-size connections
Imperial-size connections
Refnet Headers
Capacity index
Capacity index
Capacity index
Capacity index
Capacity index
< 201
201~290
291~640
> 640
< 291
Capacity index
291~640
KHRQM23M20T
KHRQ23M20T
-
KHRQM23M29T
KHRQ23M29T9
-
KHRQM23M64T
KHRQ23M64T
-
KHRQM23M75T
KHRQ23M75T
-
KHRQM23M29H
KHRQ23M29H
-
KHRQM23M64H
KHRQ23M64H
-
KHRQM22M20T
KHRQM22M29T
KHRQM22M64T
KHRQM22M75T
KHRQM22M29H
KHRQM22M64H
KHRQ22M20T
KHRQ22M29T9
KHRQ22M64T
KHRQ22M75T
KHRQ22M29H
KHRQ22M64H
continuous heating
VRV III-S
Mini VRV
VRV Classic
2-module
systems
3-module
systems
RXYSQ
BHFQ22P1007
BHFQ22P1517
BHFQ22P1007
KWC26B280
KWC26B280
KWC26B450
BEH22A10Y1L
BEH22A18Y1L
EKBPH012T +
EKBHPCBT
EKBPH020T +
EKBHPCBT
RXYCQ8A
2x BEH22A10Y1L
REMQ5
2-module
systems
3-module
systems
BHFQ23P907
BHFQ23P1357
EKBPH012T +
EKBHPCBT
outdoor
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
1 kit
per system
1 kit
per system
1 kit
per system
1 kit
per system
RWEYQ8-10T
BHFP26P36C
BHFP26P63C
BHFP26P84C
BHFQ22P1007
BHFQ22P1517
BHFQ23P907
BHFQ23P1357
KWC26B160
DTA104A53/61/62
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
DTA104A62
Installation in the RWEYQ outdoor unit possible. For installation in indoor units, use appropriate type (DTA104A53/61/62)
for particular indoor unit. See Options & Accessories of indoor units
Capacity index
1-port
1-port
4-port
4-port
6-port
6-port
8-port
10-port
12-port
16-port
> 640
KHRQM23M75H
KHRQ23M75H
-
BS1Q-A
EKBSVQLNP
BSVQ-P8B
EKBSVQLNP
BS4Q14A
-
BSV4Q100PV
-
BS6Q14A
-
BSV6Q100PV
-
BS8Q14A
BS10Q14A
BS12Q14A
BS16Q14A
KRC19-26
KRC19-26
1 kit per port
necessary
KJB111A
KHFP26A100C
KHRP26A1250C
KDDN26A4
KJB111A
KHFP26A100C
KHRP26A1250C
KDDN26A8
KHFP26A100C
KHRP26A1250C
KDDN26A12
KHFP26A100C
KHRP26A1250C
KDDN26A12
KHFP26A100C
KHRP26A1250C
KDDN26A16
KHFP26A100C
KHRP26A1250C
KDDN26A8
KRC19-26
1 kit per port
necessary
KJB111A
KHRQM22M75H
KHRQ22M75H
241
indoor
Ceiling mounted cassette units
Round flow
(800x800)
FXFQ 20~125A
FXCQ 20~40A
FXCQ 50~63A
FXCQ 80 ~125A
*4
*4
*4
*4
*4
BRC7FA532F
BRC7F530W *9*10
(white panel)
BRC7F530S *9*10
(grey panel)
BRC7EB530 *9*10
(standard panel)
BRC7C52
BRC7C52
BRC7C52
BRC2E52A
Simplified wired remote control for heat recovery system
BRC3E52A
Simplified wired remote control for heat pump system
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP4A53 *2*7
KRP4A53 *2
KRP4A51
KRP4A51
KRP4A51
BRC1D52
Standard wired remote control with weekly timer
DCS302C51
Central remote control
DCS301B51
Unified ON/OFF control
Adapters and control
2-way blow
FXZQ 15~50A
BRC1E52A/B
Premium wired remote control with full-text interface and back-light
DST301B51
Schedule timer
DCM601A51
Intelligent Touch Manager
External wired temperature sensor
External wireless temperature sensor
Adaptor for wiring (interlock for fresh air intake fan)
Wiring adapter for external monitoring/control via dry contacts and
setpoint control via 0-140
Wiring adapter for external central monitoring/control
(controls 1 entire system)
KRP2A52
KRP2A51
KRP2A51
KRP2A51
EKRP1C11 *2*7
EKRP1B2
EKRP1B2
EKRP1B2
EKRP1B2
KRP1B57 *2*7
KRP1B57
DTA114A61
DTA114A61
DTA104A61
DTA104A61
DTA104A61
KRP1H98 *7
KRP1A101
KRP1C96
KRP1C96
KRP1C96
standard
standard
standard
standard
standard
KJB212A
KJB212A
KJB212A
KJB212A
KJB311A
KJB311A
KJB311A
KJB311A
BYBCQ40H
BYBCQ63H
BYBCQ125H
KDBQ44B60
(standard panel)
KDBHQ55B140 *7
KDDQ55B140-1 +
KDDQ55B140-2 *7*8
KDDQ44XA60
KDDFP53B50
KDDFP53B80
KDDFP53B160
KAFP551K160
KAFQ441BA60
KAFP531B50
KAFP531B80
KAFP531B160
standard
standard
standard
standard
standard
BRYQ140A
KEK26-1A
KEK26-1A
KEK26-1A
Decoration panel
(obligatory for cassette units, optional for others, rear panel for FXLQ)
Kit for mounting of decoration panel direct onto unit
Panel spacer for reducing required installation height
Sealing kit for 3-directional or 2-directional air discharge
Others
4-way (600x600)
242
indoor
Small
Slim
Standard
FXKQ 25~40
FXKQ 63
FXDQ 20~25 M9
FXDQ 15~63A
FXSQ 15~32
FXSQ 40~50
FXSQ 63~80
FXSQ 100~140
*4
*4
*4
*4
*4
*4
*4
*4
BRC4C61
BRC4C61
BRC4C62
BRC4C65
BRC4C65
BRC4C65
BRC4C65
BRC4C65
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-4B
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP1BA59
KRP1BA59
KRP1BA59
KRP1BA59
KRP4A51
KRP4A51
KRP4A51
KRP4A54
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP2A51
KRP2A51
KRP2A51
KRP2A53
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP1B61
KRP1B61
EKRP1B2
KRP1B56
EKRP1B2
EKRP1B2
EKRP1B2
EKRP1B2
EKMTAC
DTA114A61
DTA114A61
DTA114A61
DTA114A61
DTA114A61
DTA104A61
DTA104A61
DTA104A61
DTA104A53
DTA104A61
DTA104A61
DTA104A61
DTA104A61
KRP1B101
tbc
tbc
tbc
tbc
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
KJB212A
KJB212A
KJB212A
KJB212A
KJB212A
KJB311A
KJB311A
KJB311A
KJB311A
KJB311A
KJB411A
KJB411A
KJB411A
KJB411A
BRP7A51
BRP7A51
BRP7A51
BRP7A51
BYK45F
BYK71F
BYBS32D
BYBS45D
BYBS71D
BYBS125D
tbc
tbc
tbc
tbc
tbc
tbc
tbc
tbc
Standard
Standard
KDAJ25K56
standard
Standard
Standard
Standard
Standard
KEK26-1A
Standard
243
indoor
Ceiling su
FXMQ 50~80
FXMQ 100~125
Large
FXMQ 200~250
*4
*4
*4
*4
*4
BRC4C65
BRC4C65
BRC4C65
BRC7G53
BRC7G53
KRCS01-4
KRCS01-4
KRCS01-1
KRCS01-4
KRCS01-4
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP4A51
KRP4A51
KRP4A51
KRP4A52
KRP4A52
KRP2A51
KRP2A51
KRP2A51
KRP2A62
KRP2A62
EKRP1B2
EKRP1B2
KRP1B61
KRP1B54
KRP1B54
BRC1E52A/B
Premium wired remote control with full-text interface and back-light
BRC1D52
Standard wired remote control with weekly timer
Infrared remote control including receiver
BRC2E52A
Simplified wired remote control for heat recovery system
BRC3E52A
Simplified wired remote control for heat pump system
DCS302C51
Central remote control
DCS301B51
Unified ON/OFF control
DCS601C51
Schedule timer
DCM601A51
Intelligent Touch Controller
External wired temperature sensor
External wireless temperature sensor
Others
FXHQ 32A
FXHQ 63A
DTA114A61
DTA114A61
DTA104A61
DTA104A61
DTA104A61
DTA104A62
DTA104A62
KRP4A96
KRP4A96
KRP1D93A
KRP1D93A
Standard
Standard
Standard
EKRORO4
EKRORO4
Standard
Standard
Standard
KJB212A
KJB212A
KJB311A
KJB311A
Decoration panel
(obligatory for cassette units, optional for others, rear panel for FXLQ)
BYBS71D
BYBS125D
EKBYBSD
EKBYBSD
KDDQ50A140
KDDQ50A140
KDAJ25K71
KDAJ25K140
KAFP501A56
KAFP501A80
KDU50P140
Standard
Standard
KDU50P60
Sensor kit
KEK26-1
KEK26-1
KHFP5M35
KHFP5N63
244
1-way blow
uspended units
indoor
FXHQ 71~100A
4-way blow
FXUQ 71~100A
FXAQ 15~63
Concealed
FXNQ 20~63
*4
*4
*4
*4
*4
*4
*4
BRC7G53
BRC7C58
BRC7EB518
BRC4C65
BRC4C65
BRC4C65
BRC4C65
KRCS01-4
KRCS01-4
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP4A52
KRP4A53 *2
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP2A62
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP1B61
KRP1B61
KRP1B61
KRP1B61
KRP1B54
DTA114A61
EKMTAC
EKMTAC
EKMTAC
EKMTAC
DTA104A62
DTA104A61
FXLQ 50~63
KRP1D93A
KRP1B97
KRP4A93
EKRORO4
EKRORO5
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
KJB212A
KJB212A
KJB311A
KJB311A
EKRDP25A
EKRDP40A
EKRDP63A
KDBHP49B140
KDBTP49B140
KDDQ50A140
KAFP551K160
KDU50P140
K-KDU572EVE
KEK26-1
KHFP5N160
KAFP501A160
245
INDOOR UNITS
CTXS15-35K
FTXS20-25K
FTXS35-50K
FTXS-G
FVXG-K
FVXS-F
FDXS-F(9)
FLXS-B(9)
BRC944 (3)
BRC944 (3)
BRC944 (3)
BRC944 (3)
BRC1D52
BRC1E52A
BRC1E52B (4)
BRC4C65
BRC2C51
BRC3A61
BRCW901A03
BRCW901A03
BRCW901A03
BRCW901A03
BRCW901A03
BRCW901A08
BRCW901A08
BRCW901A08
BRCW901A08
BRCW901A08
KRP413A1S (1)
KRP413A1S (1)
KRP413A1S (1)
KRP413A1S (1)
KRP413A1S (1)
KRP413A1S (1)
KRC72 (2)
KRC72 (2)
KRC72 (2)
KRC72 (2)
KRC72 (2)
KRC72 (2)
KRC72 (2)
KKF910A4
KKF910A4
KKF910A4
KKF910A4
KKF910A4
KKF917AA4
KRP980A1
KRP4A54
Remote sensor
KRCS01-4
KRP1BA101
KJB311A
KJB212A
KRP928A2S
KRP928A2S (5)
KRP928A2S (5)
KRP928A2S
KRP928A2S
KRP928A2S
KRP928A2S
Online controller
BRP069A41
BRP06942 (5)
BRP06942
BRP069A42
BRP069A42
BRP069A42
BRP069A42
Modbus gateway
RTD-RA
RTD-RA (5)
RTD-RA
RTD-RA
RTD-RA
RTD-RA
RTD-NET
KNX gateway
KLIC-DD
KLIC-DD (5)
KLIC-DD
KLIC-DD
KLIC-DD
KLIC-DD
KLIC-DI
KLIC-DD
FTXG-LW/S
KAZ917B41
KAZ917B42
KAF925B41
Installation leg
BKS028
(1) Wiring adapter supplied by Daikin. Time clock and other devices : to be purchased locally; (2) Wiring adapter is also required for each indoor unit; (3) Cord for wired remote control BRCW901A03 or
BRCW901A08 required; (4) Standard there is no remote control delivered with this indoor unit. Wired or wireless control to be ordered separately; (5) Interface adapter KRP980A1 required.
246
INDOOR UNITS
Description
FCQG-F
FFQ-C
FDBQ-B
FBQ-D
FHQ-C
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
DCS601C51
BRC1D528
BRC1E52A (3)
BRC1E52B(4)(9)
DCS601C51
BRC7EB530W
BRC7F530W
BRC7F530S (8-9)
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
-
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
DCS601C51 (2)
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
-
BRC4C65
BRC7G53
BRC2E52C (12)
BRC2E52C (12)
BRC3E52C (12)
BRC3A61
DCS302C51
DCS301B51
DST301B51
KRP1B57
KRP4A53 (1)(5)
-
BRC3E52C
DCS302C51
DCS301B51
DST301B51
KRP1BA59
KRP4A52 (1)
KRP2A51 (1)
DTA112B51
DCS302C51
DCS301B51
DST301B51
KRP1B54
KRP4A52(1)
-
KRP1B(A)101
KRP1D93A
KRCS01-4
KJB311A
KJB212A
EKRP1C11 (1)(5)
-
DCS302B51
DCS301B51
DST301B51
KRP1B57
KRP4A53(6)
KRP1B101
KRP1BA101
KRCS01-4
EKRP1B2
BRP7A51 (1) (13)
EKRP1B2
-
KRCS01-4B
KJB411A
BRP7A51
KRCS01-4B
EKRORO4
KJB311A
KJB212A
-
EKRP1B2A (7)
BRC7FA532F (5)
KRP1H98 (5)
Notes: (1) Installation box for adapter PCB is necessary; (2) Interface adapter for Sky Air series (DTA112B51) is necessary; (3) Including following languages: English, German, French, Italian, Spanish, Dutch, Greek, Russian, Turkish, Portuguese, Polish; (4) Including
following languages: English, German, Czech, Croatian, Hungarian, Romanian, Slovenian, Bulgarian, Slovak, Serbian, Albanian; (5) Option not available in combination with BYCQ140*G; (6) Installation box for adapter PCB (KRP1B101) is necessary; (7) Electrical
heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment; (8) Sensing function is not available; (9) Independently controllable flaps function is not available; (10) With the infrared remote control, the individual flap control and automatic air volume control cannot be controlled; (11) Including decoration panel; (12) Including following languages: English, German, French, Dutch, Spanish, Italian, Portuguese; (13) Only possible in combination with simplified remote
control BRC2/3E52C; (14) For residential use only. Cannot be used with other centralised control equipment
Notes: (1) The BYCQ140DW has white insulations. Be informed that dirt is more visible on white insulation and that it is consequently not advised to install the BYCQ140DW decoration panel in environments
247
VAM250FA
VAM350FB
VAM500FB
VAM650FB
EN779 Medium M6
EKAFV50F6
EKAFV50F6
EKAFV80F6
EN779 Fine F7
EKAFV50F7
EKAFV50F7
EKAFV80F7
EN779 Fine F8
EKAFV50F8
EKAFV50F8
EKAFV80F8
Model name
KDDM24B50
KDDM24B100
200
200
BRYMA65
BRYMA65
BRYMA65
VH1B
VH2B
VH2B
VH3B
VH3B
Dust filters
Silencer
CO2 sensor
VH electrical heater for VAM
VAM-FA/FB
VKM-GB(M)
BRC1E52A/B / BRC1D52
BRC1E52A/B / BRC1D52
BRC301B61
VAM-FA/FB
VKM-GB(M)
DCS302C51
DCS302C51
DCS301B51
DCS301B51
Schedule timer
DST301B51
DST301B51
Others
VAM150-250FA
VAM350-2000FB
VKM-GB(M)
KRP2A51
KRP2A51 (note 3)
KRP50-2
BRP4A50
Remote sensor
Notes
(1) Cool/heat selector required for operation
(2) Do not connect the system to DIII-net devices (Intelligent controller, Intelligent Manager, LonWorks interface, BACnet interface).
(3) Installation box KRP1BA101 needed.
(4) Fixing plate EKMPVAM additionally needed for VAM1500-2000FB.
(5) 3rd party heater and 3rd party humidifier cannot be combined
(6) For external control and monitoring (ON/OFF control, operation signal, error indication)
LED indicators
Power ON - Yellow
Heater ON - Red (solid or flashing, indicating pulsed control)
Airflow fault - Red
Mounting holes
Maximum ambient adjacent to terminal box
Auto high temp. cutout
Man. reset high temp. cutout
Run relay
BMS setpoint input
248
kW
mm
vH1B
VH2B
VH3B
VH4B
VH4/AB
VH5B
1
100
VAM150FA
-
1
150
VAM250FA
VAM350FB
1
200
VAM500FB
VAM650FB
1.5
250
VAM800FB
VAM1000FB
2.5
250
VAM800FB
VAM1000FB
2.5
350
VAM1500FB
VAM2000FB
VAM1000FB
VAM1500FB
VAM2000FB
VKM50GB(M)
VKM80GB(M)
EKAFV80F6
EKAFV100F6
EKAFV100F6 x2
EKAFV100F6 x2
VKM100GB(M)
-
EKAFV80F7
EKAFV100F7
EKAFV100F7 x2
EKAFV100F7 x2
EKAFV80F8
EKAFV100F8
EKAFV100F8 x2
EKAFV100F8 x2
KDDM24B100
KDDM24B100
KDDM24B100 x2
KDDM24B100 x2
KDDM24B100
KDDM24B100
250
250
250
250
250
250
BRYMA100
BRYMA100
BRYMA200
BRYMA200
BRYMA65
BRYMA100
BRYMA200
VH4B / VH4/AB
VH4B / VH4/AB
VH5B
VH5B
EKEQFCB 2
EKEQDCB 2
EKEQMCB 2
BRC1E52A/B / BRC1D52
BRC1E52A/B / BRC1D52 1
BRC1E52A/B / BRC1D52 1
EKEQFCB 2
EKEQDCB 2
EKEQMCB 2
EKEQFCB 2
EKEQDCB 2
EKEQMCB 2
KRCS01-1
Drain pan
Digital I/O PCB
Demand PCB - Required to connect room thermostat
Remote user interface (remocon) - Same controller as supplied with cascade unit
can be mounted parallel or on other location. If 2 controllers are installed, the
installer needs to select 1 master & 1 slave
Back-up heater
Wired room thermostat - Requires demand PCB EKRP1AHTA
Wireless room thermostat - Requires demand PCB EKRP1AHTA
Remote sensor for room thermostat - Requires demand PCB EKRP1AHTA
Domestic hot water tank - standward
(stacked on top of hydrobox)
Domestic hot water tank - with possibility for solar connection
HXY080-125A
HXHD125A
EKHBDPCA2
EKRP1HBAA
EKRP1AHTA
EKRUAHTB
EKBUHAA6(W1/V3)
EKRTWA
EKRTR1
EKRTETS
EKHTS200AC
EKHTS260AC
EKHWP500B
EKSV26P (vertical)
EKSH26P (horizontal)
EKSRPS
Solar collector *1
Pump station
249
Panel insulation
option
option
option
option
option
option
option
option
option
option
option
standard
standard
standard
standard
standard
standard
standard
standard
option
option
option
option
standard
standard
standard
standard
option
option
option
option
Galvanized steel
option
option
option
option
Aluminium
option
option
option
option
option
option
option
option
standard
standard
standard
standard
option
option
option
option
option
option
option
option
Galvanized steel
Internal sheet material Grey Plastisol covered galvanized steel
Aluminium
AISI 304 stainless steel
Aluminium
Base frame
Galvanized steel
Glass fibre reinforced nylon
Compression type
Type
FP 25
standard
option
Handle
FP 50
standard
Anodized aluminium
SP 45
standard
Corner
SP 65
standard
option
option
option
option
option
standard
(from size 1 to size 17)
standard
(from size 18 to size 27)
standard
option
standard
(from size 1 to size 17)
standard
(from size 18 to size 27)
standard
option
standard
(from size 1 to size 17)
standard
(from size 18 to size 27)
standard
option
standard
(from size 1 to size 17)
standard
(from size 18 to size 27)
standard
standard
standard
standard
standard
option
option
option
option
D-AHU Easy
Construction type
Profile
Aluminium
Corner
Panel insulation
DS 50
DS 25
Standard
Standard
Standard
Standard
Standard
Standard
Galvanized steel
Standard
Standard
Base frame
Aluminium
Standard
Standard
Handle
Standard
Standard
Type
Compression type
Standard
Standard
250
DCM601A51
DMS502A51
LonWorks Interface
BACnet Interface
KRP928A2S
DTA102A52
DTA112B51
KRP928A2S
DTA102A52
DTA112B51
DAM411B51
DAM412B51
DCM601A52
DCM002A51
DCM008A51
DCM009A51
WGDCMCPLR
787-712
750-613
750-960
750-600
750-400, 750-432
750-513/000-001
750-454, 750-479
750-461/020-000
DMS504B51
251
Over 30 years of
VRV History
The original VRV air conditioning
system developed by Daikin
Industries Ltd. in 1982 is
introduced into Europe in VRV
standard format. VRV D series can
supply conditioned air from up to
6 indoor units connected to
a single outdoor unit.
1987
1991
252
The introduction
of the VRVII-S series extends
the VRV operating scope
into the light commercial
sectors. Available in 4, 5 and
6HP capacities, the system is
designed for installation in
up to 9rooms.
1994
1998
2003
2004
2005
2006-2007
2008
2009
2010
2011
2012
253
Development
IT
Solution Product
Development Center
Development
Environmental Technology
Research laboratory
Environment
Five-year results for the environmental
action plan 2010
Under the five-year FUSION 10 strategic management plan,
which targeted fiscal year 2010, the Daikin Group strove to
develop and promote the use of environmentally conscious
products and services on a basic policy of actively contributing
to solving global environmental problems and expanding
business. Our environmental measures were conducted under
our Environmental Action Plan 2010.
Europe
Fifteen-fold increase in heat-pump hot water and space
heating
We have successfully promoted the use of the Daikin Altherma
hot water and space heating system in the process contributing
to the reduction of 210,000 tons of CO2 emissions.
Proliferating results
in Europe
Reduction of
210,000 tons of
CO2 emissions
compared
to using
combustiontype heaters
15 times
2006
2010
HEAT PUMP
HEATERS 4%
FY 2010
FY
255
256
Literature
overview
Daikin has a wide portfolio of commercial
catalogues in order to supply you with information
or help you to sell our products to your customers.
258
259
257
Literature Overview
Hotel Solutions
Hotel solutions
for installers
Heating - air conditioning - domestic hot water - cooling - ventilation - centralised control
15-217
Reference
books:
REFERENCE
C ATA LO G U E
C O M M E R C I A L A P P L I C AT I O N S
Product
profiles:
VRV IV range
VRV IV
360 efficiency
Rooftop UATYQ-CY1
Rooftop
UATYQ-CY1
Focus
topics:
Replacement
technology
for installers
The quick and quality way of upgrading R-22 and R-407C systems
Product
flyers:
Real time clock
Other features
Backlight display
User friendly
remote control
with contemporary
design
Specifications / Functions
Specifications
BRC1E52A / BRC1E52B
Dimensions (HxWxD)
3.120x120x19 mm40
Display size (HxW)
LCD
43.2x68.85 mm
Type
Colour
Fresh white
No
500m
Functions
BRC1E52A / BRC1E52B
Set sensor behavior
Energy saving
functions
Setback function
15-214
15-140
Detailed info on
BRC1E52A/B remote
control
KNX Interface
Split
KNX Interface
KLIC-DD, KLIC-DI
EKMBDXA
DIII-net modbus
gateway
English, German, Czech, Croation, Hungarian, Romanian, Slovenian, Bulgarian, Slovak, Serbian, Albanian
Holiday function
Key lock
Restrict buttons
Built-in back-up power
Contrast adjustment
Timer
Technical cooling
English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, Polishr
Help menu
Display
Replacement
Technology
BRC1E52A/B
15-120
15-206
Naamloze Vennootschap Zandvoordestraat 300 8400 Oostende Belgium www.daikin.eu BE 0412 120 336 RPR Oostende (Responsible Editor)
FSC
ECPEN15 - 306
180 11/14
The present publication is drawn up by way of information only and does not constitute an offer binding upon
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its
content and the products and services presented therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.
15-306
central controller
VH
Wireless room
temperature
sensor
K.RSS
15-310
Wireless temperature
sensor
RTD
15-311
Detailed technical
information & benefits
on Sky Air/Ventilation/
Biddle Air Curtain/Control
systems/AHU
15-114
Product portfolio
Sky Air
15-309
Retail applications
Hotel applications
IT applications
Heating interlock
Alarm signal
VRV Catalogue
Sky Air
Product
portfolios:
Product
catalogues:
Modbus
Interface
15-312
Split, Sky Air, VRV, Chillers,
VRV
15-308
Ventilation Catalogue
Detailed technical
information & benefits of
the VRV total solution
Detailed info on
Ventilation products
First half 2015
15-200
15-203
VRV
Product Portfolio
Controls
Controls systems
portfolio
22
15-121
258
15-201
15-301
Commercial Solutions
Green building
solutions
15-100
15-216
Sustainable design
with Daikin HVAC-R systems
Reference
catalogue
Hotel Solutions
Daikin commercial
and industrial
references
Hotel solutions
for hotel owners
14-213
Intelligent Touch
Manager
Detailed benefits of
Intelligent Touch Manager
15-302
Act now!
Replacement technology
15-215
Powerful mode
Concealed
ceiling unit
with medium
ESP
FBQ-D, FXSQ-A
Home leave
Home leave
operation
Powerful mode
Multi tenant
(FXNQ-A)
15-106
15-101
Technical documentation:
Download all technical documentation such as engineering databooks, selection software, installation and
operation manuals and service manuals directly from our extranet: extranet.daikineurope.com
259
Literature Overview
Heat Recovery
360
installation
efficiency
efficiency
operational
efficiency
design
efficiency
FAST
design
+ QUICK
+ MORE
+
installation
free heat
MAX
comfort
Our new VRV IV heat recovery systems sets pioneering standards in all-round climate comfort efficiency.
Total design simplicity, rapid installation, full flexibility
with absolute efficiency and comfort. Find out about all
revolutionary changes on www.daikineurope.com/vrviv
Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 8400 Oostende Belgium www.daikin.eu BE 0412 120 336 RPR Oostende (Responsible Editor)
FSC
ECPEN15 -200
xxx 02/15
The present publication is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has
compiled the content of this publication to the best of its knowledge. No express
or implied warranty is given for the completeness, accuracy, reliability or fitness
for particular purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice. Daikin Europe
N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest
sense, arising from or related to the use and/or interpretation of this publication.
All content is copyrighted by Daikin Europe N.V.