pipe wall.
Pipe wall
(e. g. PE)
Coupling medium
(e. g. water)
Ultrasonic
sensor
Pipe wall
(e. g. PE)
Coupling medium
(e. g. water)
Ultrasonic
sensor
other
The time difference is multiplied by sonic velocity so that this way a
Coupling medium
(e. g. water)
Back wall
echo
Entrance
echo
Ultrasonic
sensor
(correction factor)
mm
kg/h
MK / SC
+Job calibration
man. values
act. values
freeze
IUS
US-speed mean
3.51
3.50
3.50
3.53
3.51
3.50
freeze
calibration
calibration function.
Corr.Wt [%]
Corr. Seg.1
Corr. Seg.2
...
Corr. Seg.8
without
gravimetric
1
2
7
segments
6
manual
calibration
3
5
The manual calibration calculates the mean ultrasonic speed and the
segment corrections.
Corr.Wt [%]
without grav.
corr. Wt =0 Correction US-speed
Corr. Seg.1
Corr. Seg.2
Corr. Seg.3
Corr. Seg.4
Corr. Seg.5
Corr. Seg.6
Corr. Seg.7
Corr. Seg.8
ECCO - operation
Segmented calibration
ECCO - operation
Start up window
ECCO - operation
Produktion Window
Set value
ECCO - operation
Segmented calibration
Gain in %
Pre Gain1
Pre Gain2
Code
Term
Explanation
Trk.
Track
Numbering of the
measurements clock wise
Chan
Channel
RTV
Run Time
Value
WDL
Water Delay
DME
Dynamic
Quantity of disturbances
measurement
disturbance
suppression
Amp
Amplification
Ref
Reference
Sensor
Diagnose mask
Gain in %
Gain in total
Optimum range
Acceptable range
Questionned range
Generally out of the range
PreGain1
Gain in %
0 - 100
0 - 60
60 - 80
80 - 100
90 - 100
PreGain2
PreGain1
1
0
0
0
1
PreGain2
1
0
0
0
1
ECCO - operation
Oszilloscope
To shift the
displayed area
To choose the
sensor. It is
numbered clock
wise against
extrusion
direction.
Track 0 is on top.
To choose the
layer
ECCO - operation
Oszilloscope
Abbrev.
Value
GS
Gate Start
Gate
Blt
Blocking
Time
Wdl
Rtv
amp
Usage
Delay time to start the gate in microseconds [us]
Length of the gate [us] (gate = measurement area)
Blocked out time after the outer wall signal is found [us]
water flow
ABE-function:
If the ABE-formulation is
activated in the ius-basic
settings, the US-parameter
gate, gate start and
blocking time are
calculated automatically by
the ABE-function.
sensor distance
water delay
Ie
Re
blt
rtv
gate start
gate
EE
Recipe:
Od cal
Lt-min
v-sonic default
RE
Gain
IUS-Parameter:
sensor distance
ABE
(automatic gate setting)
BLT
RTV
Gate start
gate
Gate
Gatestart
Blocking
time
ECCO - operation
Settings
AutoSet Tolerance When the wall thickness exceeds the set value + AutoSetTolerance, the
numbers for the wall thickness will turn into red letters.