You are on page 1of 5

Altivar

00175555514040

VW3 A5 101 ... A5 108

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Read and understand this manual and the manuals of the drive before installing this option.
Installation must be performed by qualied personnel
The user is responsible for compliance with all international and national electrical code requirements with respect
to grounding of all equipment.
Many parts of this drive, including the printed circuit boards, operate at the line voltage. DO NOT TOUCH. Use only
electrically insulated tools.
DO NOT touch unshielded components or terminal strip screw connections with voltage present.
DO NOT short across terminals PA/+ and PC/ or across the DC bus capacitors.
Before servicing the drive:
- Disconnect all power, including external control power that may be present.
- Place a DO NOT TURN ON label on all power disconnects.
- Lock all power disconnects in the open position.
- WAIT 15 MINUTES to allow the DC bus capacitors to discharge.
- Measure the voltage of the DC bus between the PA/+ and PC/ terminals to ensure that the voltage is less than 42 Vdc.
- If the DC bus capacitors do not discharge completely, contact your local Schneider Electric representative. Do not repair
or operate the drive.
Install and close all covers before applying power or starting and stopping the drive.
Failure to follow these instructions will result in death or serious injury.
Electrical equipment should be installed, operated, serviced, and maintained only by qualifed personnel. No responsibility
is assumed by Schneider Electric for any consequences arising out of the use of this product.
2010 Schneider Electric. All Rights Reserved.

W9 1755555 01 14 A04
12 - 2010
1/5

VW3 A5 101

12 A

VW3 A5 102

48 A

VW3 A5 103

90 A

VW3 A5 104

3 x 215 A

VW3 A5 105

3 x 314 A

VW3 A5 106

3 x 481 A

VW3 A5 107

3 x 759 A

VW3 A5 108

3 x 1188 A

VW3 A5 101 ... 103

VW3 A5 104 ... 108

L3
S
E

W/T3

S
E

V/T2

U/T1

L1

L3

L2

L1

ATVppppppp

W/T3

W/T3

V/T2

U/T1

U/T1

V/T2

ATV ppppppp

L2

3a

3a

M1
3a

M1
3a

www.schneider-electric.com
... N.m
... lb.in

10

2/5

u100

u3.94

u100

u3.94

VW3 A5 101 ... 102

4x
H
c

G
a

mm

in

mm

in

mm

in

mm

in

mm

in

mm

VW3 A5 101

190

7.48

210

8.27

90

3.54

170

6.69

45

1.77

8 x 12 0.31 x 0.47

in

VW3 A5 102

190

7.48

235

9.25

120

4.73

170

6.69

48

1.89

8 x 12 0.31 x 0.47

u 100

u3.94
u3.94

u 100

VW3 A5 103

4x
G
a

H
c1
c

a
VW3 A5 103

c1

mm

in

mm

in

mm

in

mm

in

mm

in

mm

234

9.21

226

9.21

126

4.96

101

3.98

180

7.09

79

3/5

in

mm

in

3.11 8 x 13 0.31 x 0.51

u 100
u 3.94

VW3 A5 104 ... 105

G
a

u 100
u 3.94

4x
H
c

in

mm

in

mm

in

mm

in

mm

in

mm

VW3 A5 104

170

6.69

250

9.84

100

3.94

150

5.91

75

2.95 9 x 18 0.35 x 0.71

VW3 A5 105

210

8.27

250

9.84

110

4.33

175

6.89

75

2.95 9 x13 0.35 x 0.51

100
3.94

mm

50
1.97

50
1.97

100
3.94

50
1.97

20
0.79

50
1.97

50
1.97

20
0.79

100
3.94

100
3.94

50
1.97

4/5

in

u 150
u 5.91

VW3 A5 106 ... 108

H
c

G
a

a
VW3 A5 106

u 150
u 5.91

4x

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

245

9.65

250

9.84

200

7.87

225

8.86

175

6.89

0.35

320 12.60

250

9.84

220

8.66

275 10.83

200

7.87

0.35

370 14.57

250

9.84

230

9.06

325 12.80

200

7.87

0.35

150
5.91

VW3 A5 107
VW3 A5 108

50
1.97

50
1.97

150
5.91

50
1.97

20
0.79

50
1.97

50
1.97

20
0.79

150
5.91

150
5.91

50
1.97

5/5

You might also like