Top 10 Electrical Mistakes

Wiring problems and mistakes are all too common, and if left uncorrected have the potential to
cause short circuits, shocks and even fires. Here's what to look for and how to fix what you find.

Mistake 1: Making Connections Outside Electrical Boxes


Mistake: No electrical box
Never connect wires outside of electrical boxes. Junction boxes protect the connections from accidental
damage and contain sparks and heat from a loose connection or short circuit.
Solution: Add a box

Where connections aren't contained in an electrical box, install a box and reconnect the wires inside it.
The photo shows one way to do this for an exterior light mounted on wood siding.

Mistake 2: Cutting Wires Too Short


Mistake 2: Wires too short
Wires that are cut too short make wire connections difficult andsince you're more likely to make poor
connectionsdangerous. Leave the wires long enough to protrude at least 3 in. from the box.
Solution: Extend wires

If you run into short wires, there's an easy fix. Simply add 6-in. extensions onto the existing wires. The
photo shows a type of wire connector that's easier to install in tight spots. You'll find these in hardware
stores and home centers.

Mistake 3: Leaving Plastic-Sheathed Cable Unprotected


Mistake: Unprotected cable

It's easy to damage plastic- sheathed cable that's left exposed between framing members. That's why the
electrical code requires cable to be protected in these areas. Cable is especially vulnerable when it's run
over or under wall or ceiling framing, as shown here.
Solution: Install a 2 x 2
Protect exposed plastic- sheathed cable by nailing or screwing a 1-1/2-in.-thick board alongside the cable.
You don't have to staple the cable to the board.

Mistake 4: Poor Support for Outlets and Switches

Mistake: Loose outlet


Loose switches or outlets can look bad, but worse yet, they're dangerous. Loosely connected outlets can
move around, causing the wires to loosen from the terminals. Loose wires can arc and overheat, creating
a potential fire hazard.
Solution: Add rigid spacers
Fix loose outlets by shimming under the screws to create a tight connection to the box. You can buy
special spacers like we show here at home centers and hardware stores. Other options include small
washers or a coil of wire wrapped around the screw.

Mistake 5: Installing a Three-Slot receptacle without a Ground


Wire
Solution: Install a two-slot outlet
If you have two-slot outlets, it's tempting to replace them with three-slot outlets so you can plug in threeprong plugs. But don't do this unless you're sure there's a ground available. Use a tester to see if your
outlet is grounded. A series of lights indicates whether the outlet is wired correctly or what fault exists.
These testers are readily available at home centers and hardware stores.
If you discover a three-slot outlet in an ungrounded box, the easiest fix is to simply replace it with a twoslot outlet as shown.

Mistake 6: Recessing Boxes Behind the Wall Surface


Mistake: Exposed combustible material
Electrical boxes must be flush to the wall surface if the wall surface is a combustible material. Boxes
recessed behind combustible materials like wood present a fire hazard because the wood is left exposed
to potential heat and sparks.
Solution: Add a box extension

The fix is simply to install a metal or plastic box extension. If you use a metal box extension on a plastic
box, connect the metal extension to the ground wire in the box using a grounding clip and a short piece of
wire.

Mistake 7: Installing Cable Without a Clamp


Mistake: Missing clamp
Cable that's not secured can strain the connections. In metal boxes, the sharp edges can cut the
insulation on the wires. Single plastic boxes do not require internal cable clamps, but the cable must be
stapled within 8 in. of the box. Larger plastic boxes are required to have built-in cable clamps and the

cable must be stapled within 12 in. of the box. Cables must be connected to metal boxes with an
approved cable clamp.
Solution: Install a clamp
Make sure the sheathing on the cable is trapped under the clamp, and that about 1/4 in. of sheathing is
visible inside the box. Some metal boxes have built-in cable clamps. If the box youre using doesn't
include clamps, buy clamps separately and install them when you add the cable to the box.

Mistake 8: Overfilling Electrical Boxes


Mistake: Box too small

Too many wires stuffed into a box can cause dangerous overheating, short-circuiting and fire. The
National Electrical Code specifies minimum box sizes to reduce this risk.
Solution: Install a larger box
To figure the minimum box size required, add up the items in the box:
1 - for each hot wire and neutral wire entering the box
1 - for all the ground wires combined
1 - for all the cable clamps combined
2 - for each device (switch or outletbut not light fixtures)
Multiply the total by 2.00 for 14-gauge wire and by 2.25 for 12-gauge wire to get the minimum box size
required in cubic inches. Then choose a box with at least this much volume. Plastic boxes have the
volume stamped inside, usually on the back. Steel box capacities are listed in the electrical code. Steel
boxes wont be labeled, so you'll have to measure the height, width and depth of the interior. Then
multiply to find the volume.

Mistake 9: Reversing Hot and Neutral Wires


Solution: Identify the neutral terminal
Connecting the black hot wire to the neutral terminal of an outlet creates the potential for a lethal shock.
The trouble is that you may not realize the mistake until someone gets shocked, because lights and most
other plug-in devices will still work; they just won't work safely.
Always connect the white wire to the neutral terminal of outlets and light fixtures. The neutral terminal is
always marked. It's usually identified by a silver or light-colored screw. Connect the hot wire to the other
terminal. If there's a green or bare copper wire, that's the ground. Connect the ground to the green
grounding screw or to a ground wire or grounded box.

Mistake 10: Wiring a GFCI Backward


Solution: Connect power to the line terminals
GFCI (ground fault circuit interrupter) outlets protect you from a lethal shock by shutting off the power
when they sense slight differences in current. They have two pairs of terminals. One pair, labeled line, is
for incoming power for the GFCI outlet itself. The other set is labeled load and provides protection for
downstream outlets. You'll lose the shock protection if you mix up the line and load connections.