You are on page 1of 4

Manual Version: APW101-20131212

BOM: 3123A0R4

H3C SecPath M9000 NSQ1SUPB0 MPU manual


1 Card view
Figure 1 NSQ1SUPB0 MPU

2 Specifications
Figure 2 Front panel of the NSQ1SUPB0

6 7

(1) Console port (CONSOLE)

(2) 10/100/1000BASE-T copper combo port GE3

(3) Management Ethernet port LED

(4) Fan status LED

(5) Card status LED

(6) MPU status LED (ACTIVE)

(7) Reset button

Table 1 Card specifications


Item

Specification

Dimensions (H W D)

40 399 352 mm (1.57 15.71 13.86 in)

Power consumption

45 W to 50 W

Weight

2.97 kg (6.55 lb)

Hot swapping

Supported

Connector type

RJ-45

Interfaces

1 console port
One 10/100/1000BASE-T Ethernet port

Ambient temperature

Operating: 0C to 45C (32F to 113F)


Not operating: 40C to +70C (40F to +158F)

Manual Version: APW101-20131212

Item

BOM: 3123A0R4

Specification

Ambient relative humidity


Compatible device model
and slot

Operating: 10% to 95%, noncondensing


Not operating: 5% to 95%, noncondensing

M9006 multi-service security gateway (Slot 0 and Slot 1)


M9010 multi-service security gateway (Slot 4 and Slot 5)
M9014 multi-service security gateway (Slot 6 and Slot 7)

Table 2 Console port specifications


Item

Specification

Connector

RJ-45

Interface standard

RS-232

Transmission baud rate

9600 bps (default) to 115200 bps

Transmission medium

Asynchronous serial cable

Transmission distance

15 m (49.21 ft)

Provides connection to an ASCII terminal.


Provides connection to the serial port of a local or remote (through a

Services

pair of modems) PC running terminal emulation program.

Supports command line interface (CLI)


Table 3 10/100/1000BASE-T copper port specifications
Item

Specification

Connector

RJ-45

Interface standard

802.3, 802.3u, and 802.3ab

Interface type

MDI/MDIX autosensing

Supported cable

Category-5 (or above) twisted pair cable

Transmission distance

100 m (328.08 ft)

Port transmission rate

10 Mbps, half/full duplex


100 Mbps, half/full duplex
1000 Mbps, full duplex

3 LEDs
Table 4 Ethernet port LED description
LINK

ACT

Description

On

Flashing

A link is present, and the management Ethernet port is receiving or


sending data.

On

Off

A link is present.

Off

Off

No link is present.

ii

Manual Version: APW101-20131212

BOM: 3123A0R4

Table 5 Ethernet port LED description


OK

FAIL

Description

On

Off

The fan tray is operating correctly.

Off

On

A fan problem is present or the fan tray is not in position.

Off

Off

The gateway is not powered on.

Table 6 MPU RUN and ALM LED description


RUN

ALM

Description

Flashing

Off

The card is operating correctly.

Flashing

On

If the LED flashes continuously, the software version of the device does
not match that of the card.

On

On

The card is booting or faulty.

On

Off

The MPU is starting up.

Off

Off

The card is not in position.

The card is loading software.

NOTE:
A quick flashing RUN LED indicates that the card is starting up rather than operating properly.
It is normal that the ALM LED for an LPU lights for a period of time at the initial phase of the system
startup.
Table 7 MPU ACTIVE LED description
LED status

Description

On

The MPU is active.

Off

The MPU is in standby status.


The MPU is faulty. Examine the card LED for an MPU problem.

4 Installing and removing the NSQ1SUPB0 MPU


CAUTION:
Wear a well-grounded ESD-preventive wrist before you install or remove the card.
Do not touch the surface-mounted components directly with your hands when you install or remove the
card.

4.1 Installing the NSQ1SUPB0


1.

Face the front panel of the device.

2.

Identify the slot to install the card, and remove the filler panel from the slot.
This manual uses slot 1 as an example.

iii

Manual Version: APW101-20131212

BOM: 3123A0R4

3.

Place the card horizontally with the surface-mounted components facing upward. Pull outward the
ejector levers and gently push the card in along the slot guide rails until the card is in close contact
with the backplane. (See callout 1 in Figure 3 .)

4.

Push the ejector levers inward. (See callout 2 in Figure 3 .)

5.

Tighten the captive screws with a Phillips screwdriver to secure the card in the slot. (See callout 3
in Figure 3 .)

Figure 3 Installing the NSQ1SUPB0

(1) Gently push the card in along the slot guide rails until the card is in close contact with the backplane.
(2) Push the ejector levers inward.
(3) Tighten the captive screws with a Phillips screwdriver, and installation is finished.

4.2 Removing the NSQ1SUPB0


1.

Use a Phillips screwdriver to loosen the captive screws at both sides of the card until all pressure
is released.

2.

Pull the ejector levers at both sides of the card outward, and pull the card along the guide rails until
it completely comes out of the backplane.

3.

Place the card on an anti-static workbench with the surface-mounted components up, or put it in an
anti-static bag.
If no new card is to be installed, install a filler panel to prevent dust and ensure good ventilation in
the device.

5 Software upgrade
For more information, see the release notes.

6 Obtaining documentation
Take the following steps to get the latest documentation from the H3C website at www.h3c.com:
1.

Go to http://www.h3c.com/portal/Technical_Documents, or click Technical Support &


Documents > Technical Documents on the top navigation bar at http://www.h3c.com.

2.

Choose the desired product category and model.

Copyright 2013 Hangzhou H3C Technologies Co., Ltd.


iv

You might also like