Se) bee
Indian Register of Shipping
Our Ref: CHN/NC/KSINC/25/09/1097 Date: 17.09.09
Kerala Shipping And Inland Navigation Corpn. Ltd.,
Kochi.
Sub:- Kerala Shipping And Inland Navigation Corpn Ltd.
Yard No. 25.
Dear Sir,
Please refer to your letter No.C-666/2009 dated 23.07.09 and return herewith understated
drawings.
Drawing No. Plan Title Status
DN7250/324 Bulwark And Railing Approved
DN7250/325 Details of Manhole Approved
DN7250/326 Details of Ladders Approved
DN7250/333 Details of Inclined Ladders RevoeneD
DN7250/328 Details of Hatch RETUENED
Note:
‘The attached list of remarks is part of this letter, Please address these comments by reply
tous.
Status “Approved” indicates:
‘The scantlings and arrangements as shown in the stated plans and amended thereon
would be approved provided the work is carried out to the Surveyors satisfaction and the
Rules in all other respects are complied with.
Status “Retumed” indicates:
‘The stated plans are Retumed herewith our comments. The plans are to be resubmitted
‘or approval incorporating our comments,
‘Thanking you,
‘Yours faithfully,
Fox The Surveyors,
a
D. SAHA
SHIP SURVEYOR,
Enel: drawings & comments
Page 1 of 2Ann
etter Ref.: | NC/001263/2009092160
Yard Name: Kerala Shipping & Inland Navigation Corpn. Ud.
dalec ‘Aqles
nen de IRS Lelly nor CHW |W] i¢ sive] 25/09/1057
eu
Yard Number: 25
S.No. Drawing No., Plan Tile & Comments
Clearing
Responsibility
Cleared Cleared
By
Date
7
M
12
'DN7250/324 - REV.0
BULWARK & RAILING
The bulwarks are generaily not fo be welded to the
op of shear strake within 0.6 L amidships.
The freeing arrangements os shown on the plan is not
in order. The freeing port area to be in accorciance
with Section 5.4 Chapter 11,Part 3 of Rules. The
calculations may also be forwarded for our reference.
The clear opening below the lowest course of guard
falls is not to exceed 230 mm. Kindly refer section 5.6,
‘Chapter 11, Parl 3 of Rules for further details.
The guard rails to be as per National/ Intemational
standard,
HO,
Ho.
HO.
HO.
24
22
1DN7250/325 - REV.
DETAILS OF MANHOLES
We note that access manholes fo sewage tank, dirty
oil tank, chain locker etc is not shown. We conclude
that adequate access fo all the tanks would be
Provided to surveyors satisfcation,
The manholes to be as per Natlonol/ Intemational
slondards.
SS.
SS.
1
'DN7250/326 - REV.O
DETAILS OF LADDERS
The vertical ladders to be in accordance with
Notional Intemational standards.
SS.
Al
42
43
1DN7250/S28 - REV.O
DETAILS OF HATCH
‘The details of hatch to be as per National/international
standard.
The arrangement of the toggles to be in accordance
with Section 7.1.4, Chapter 12, Part 3 of Rules.
‘Coaming heights are to be measured from top of the
deck sheathing if fitted,
HO.
HO.
88.
Bl
52
'DN7250/333 - REV.0
DETAILS OF INCLINED LADDERS.
The inclined stairways as shown to be in compliance
with Section 13.3, Chapter 8, Part 6 of Rules.
The inclined stairways to be in accordance with
Nationai/ international Standard.
HO.
Ss.
Page 2/ 2