You are on page 1of 2
Se) bee Indian Register of Shipping Our Ref: CHN/NC/KSINC/25/09/1097 Date: 17.09.09 Kerala Shipping And Inland Navigation Corpn. Ltd., Kochi. Sub:- Kerala Shipping And Inland Navigation Corpn Ltd. Yard No. 25. Dear Sir, Please refer to your letter No.C-666/2009 dated 23.07.09 and return herewith understated drawings. Drawing No. Plan Title Status DN7250/324 Bulwark And Railing Approved DN7250/325 Details of Manhole Approved DN7250/326 Details of Ladders Approved DN7250/333 Details of Inclined Ladders RevoeneD DN7250/328 Details of Hatch RETUENED Note: ‘The attached list of remarks is part of this letter, Please address these comments by reply tous. Status “Approved” indicates: ‘The scantlings and arrangements as shown in the stated plans and amended thereon would be approved provided the work is carried out to the Surveyors satisfaction and the Rules in all other respects are complied with. Status “Retumed” indicates: ‘The stated plans are Retumed herewith our comments. The plans are to be resubmitted ‘or approval incorporating our comments, ‘Thanking you, ‘Yours faithfully, Fox The Surveyors, a D. SAHA SHIP SURVEYOR, Enel: drawings & comments Page 1 of 2 Ann etter Ref.: | NC/001263/2009092160 Yard Name: Kerala Shipping & Inland Navigation Corpn. Ud. dalec ‘Aqles nen de IRS Lelly nor CHW |W] i¢ sive] 25/09/1057 eu Yard Number: 25 S.No. Drawing No., Plan Tile & Comments Clearing Responsibility Cleared Cleared By Date 7 M 12 'DN7250/324 - REV.0 BULWARK & RAILING The bulwarks are generaily not fo be welded to the op of shear strake within 0.6 L amidships. The freeing arrangements os shown on the plan is not in order. The freeing port area to be in accorciance with Section 5.4 Chapter 11,Part 3 of Rules. The calculations may also be forwarded for our reference. The clear opening below the lowest course of guard falls is not to exceed 230 mm. Kindly refer section 5.6, ‘Chapter 11, Parl 3 of Rules for further details. The guard rails to be as per National/ Intemational standard, HO, Ho. HO. HO. 24 22 1DN7250/325 - REV. DETAILS OF MANHOLES We note that access manholes fo sewage tank, dirty oil tank, chain locker etc is not shown. We conclude that adequate access fo all the tanks would be Provided to surveyors satisfcation, The manholes to be as per Natlonol/ Intemational slondards. SS. SS. 1 'DN7250/326 - REV.O DETAILS OF LADDERS The vertical ladders to be in accordance with Notional Intemational standards. SS. Al 42 43 1DN7250/S28 - REV.O DETAILS OF HATCH ‘The details of hatch to be as per National/international standard. The arrangement of the toggles to be in accordance with Section 7.1.4, Chapter 12, Part 3 of Rules. ‘Coaming heights are to be measured from top of the deck sheathing if fitted, HO. HO. 88. Bl 52 'DN7250/333 - REV.0 DETAILS OF INCLINED LADDERS. The inclined stairways as shown to be in compliance with Section 13.3, Chapter 8, Part 6 of Rules. The inclined stairways to be in accordance with Nationai/ international Standard. HO. Ss. Page 2/ 2

You might also like