Chapter 6 Diag Operation

Revision Record
Refer to the portion indicated by change bar in each section.
Also refer to the reasons in table below.

Version

Issue date

Note

Version 0.9

December 26, 2014

Version 0.9 issued.

Version 1.0

February 20, 2015

Version 0.9 has been reviewed and corrected.

Table of Contents
6.1 CE Mode Overview.....................................................................................................6-1
6.1.1 Functions of the Control Panel in the CE Mode.............................................................................. 6-1
6.1.2 How To Enter the CE Mode ............................................................................................................ 6-2
6.1.3 Overview of the CE Mode Operation .............................................................................................. 6-2
6.1.4 How to Exit the CE Mode................................................................................................................ 6-3
6.1.5 Menu Tree....................................................................................................................................... 6-4
6.1.6 CE Mode Functions Overview ........................................................................................................ 6-8

6.2 ESS Diag ..................................................................................................................6-12


6.2.1 ALL Test........................................................................................................................................ 6-12
6.2.2 Flash ROM Test............................................................................................................................ 6-13
6.2.3 EEPROM Test .............................................................................................................................. 6-13
6.2.4 DRAM Test ................................................................................................................................... 6-14
6.2.5 MAC+PHY Test............................................................................................................................. 6-14
6.2.6 ASIC Test...................................................................................................................................... 6-14
6.2.7 IOT Test ........................................................................................................................................ 6-15
6.2.8 USB Host Test .............................................................................................................................. 6-15
6.2.8.1 TEST MODE ......................................................................................................................... 6-15
6.2.8.2 Single Step ........................................................................................................................... 6-16
6.2.8.3 Get Device Info ..................................................................................................................... 6-17
6.2.9 RTC Test....................................................................................................................................... 6-18
6.2.10 eMMC Test ................................................................................................................................. 6-18
6.2.11 NFC Test..................................................................................................................................... 6-18

6.3 IOT Diag ...................................................................................................................6-19


6.3.1 Digital Input ................................................................................................................................... 6-19
6.3.2 Digital Output ................................................................................................................................ 6-21
6.3.3 NVM Settings ................................................................................................................................ 6-24
6.3.3.1 NVM Read and Write (NVM Edit) ......................................................................................... 6-25
6.3.3.2 NVM Saving (SaveNVM to ESS) .......................................................................................... 6-27
6.3.3.3 NVM Loading (LoadNVM from ESS) .................................................................................... 6-28
6.3.4 ROS Exposure .............................................................................................................................. 6-29
6.3.5 Dew Prevention............................................................................................................................. 6-30
6.3.6 ATC Mode..................................................................................................................................... 6-31

6.4 Print Info ...................................................................................................................6-32


6.4.1 Printing Printer Configuration Report (Config Page)..................................................................... 6-32
6.4.2 Printing Printer Settings Report (Print Settings)............................................................................ 6-33

6.5 Installation Settings (Installation Set) .......................................................................6-35


6.6 Print Function Test (Test Print).................................................................................6-39
6.6.1 Procedure for the Print Function Test ........................................................................................... 6-39
6.6.2 Test Pattern (Test Pat 600 [IOT]).................................................................................................. 6-40
6.6.3 Gradation ...................................................................................................................................... 6-41

6.7 Parameter Setting (Parameter) ................................................................................6-42

6.7.1 Registration Parameter Settings (Regi) ........................................................................................ 6-42


6.7.2 Life Counter Display and Counter Initialization (Life).................................................................... 6-44
6.7.3 Parameter List Print (Print) ........................................................................................................... 6-46

6.8 Board Diag (Board Test)...........................................................................................6-47


6.8.1 All Test .......................................................................................................................................... 6-47
6.8.2 Fax Memory Test .......................................................................................................................... 6-47
6.8.3 I/F Test.......................................................................................................................................... 6-47
6.8.4 ASIC Test...................................................................................................................................... 6-48
6.8.5 Relay/Signal Test.......................................................................................................................... 6-48

6.9 Information................................................................................................................6-52
6.9.1 Scan Counter ................................................................................................................................ 6-52

6.10 Scanner Maintenance.............................................................................................6-53


6.10.1 White Balance............................................................................................................................. 6-53
6.10.2 Shading Parameter ..................................................................................................................... 6-53
6.10.3 Registration Parameter ............................................................................................................... 6-54
6.10.4 Auto Registration ........................................................................................................................ 6-54
6.10.5 Sensor Parameter....................................................................................................................... 6-54
6.10.6 Vertical Scan Mag....................................................................................................................... 6-55
6.10.7 Test Pattern ................................................................................................................................ 6-55
6.10.8 IIT I/O Check............................................................................................................................... 6-55
6.10.9 Scan Counter Clear .................................................................................................................... 6-56
6.10.10 Carriage Drive_100................................................................................................................... 6-56

6.11 System Data Setting (Parameter)...........................................................................6-57


6.12 Backup (BackUP Data)...........................................................................................6-73

Chapter 6 Diag Operation


6.1 CE Mode Overview

6.1 CE Mode Overview


The CE mode is for the service engineers working for solving troubles at customer sites, and helps them identify which replaceable part of the printer causes of the trouble.

6.1.1 Functions of the Control Panel in the CE Mode


Start the Diag mode by using the buttons on the control panel.

[2], [4], [5], [6]:


Use these hard buttons to start the CE mode.

After entering the CE mode, use the buttons displayed on the touch panel and messages in the display for
operation.

[ ]:
Moves upward one by one. Pressing this at the top of the list will return to the bottom.
[ ]:
Moves downward one by one. Pressing this at the bottom of the list will return to the top.
[ ]:
Moves the cursor to the left by one.
[ ]:
Moves the cursor to the right by one.
[OK] button :
Press the [OK] button to confirm the selection or execute the processing.
[<--] (Back) button :
Press the [<--] (Back) button to cancel the selection or stop the processing.
Gyrfalcon Service Manual Version 1.0

6-1

Chapter 6 Diag Operation


6.1 CE Mode Overview

6.1.2 How To Enter the CE Mode


1

Hold down the [4], [5], and [6] buttons and turn on the power of the printer.

Diag Password.

Press the [2] button twice, and then press the [5] button once.

CE Mode
* Printer Diag
FAX/Scanner Diag

Please wait.

6.1.3 Overview of the CE Mode Operation


After the CE mode is started, you can use the buttons displayed in the touch panel to operate the CE mode.
There are two types of the diagnostic procedure: Printer Diag and Fax/Scanner Diag.
1

Selecting the item to execute the diagnosis


Use the [ ] and [ ] buttons to select the item to execute diagnosis.

Confirming the item to execute the diagnosis


Press the [OK] button to confirm the item selected.

Executing the diagnosis for the item selected


Follow the message and keep holding down the [OK] button until the diagnosis is started.
If the diagnosis requires changing the parameter value, use the [ ] and [ ] buttons and then
press the [OK] button.

To execute the diagnosis for other items, press the [<--] (Back) button until the screen returns to the item to
evaluate.
If any error occurs while in the diagnosis or in the middle of selecting parameter values, an error message will
appear and the processing will stop.
To cancel the error message and return to the menu screen, press the [<--] (Back) button or the [OK] button.

6-2

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.1 CE Mode Overview

6.1.4 How to Exit the CE Mode


You can exit the CE mode both from Printer Diag and Fax/Scanner Diag.
1

Return to the top level of Printer Diag or Fax/Scanner Diag, and use the [ ] or [ ] button until
the [Complete] appears, and then press the [OK] button.
(e.g.: To exit the CE mode from Printer Diag, display the message below.)

Printer Diag
Complete

Complete
Complete

Press the [OK] button.

Complete
Complete?

Press the [OK] button again, and the printer will exit the CE mode and re-start (same as the
power on).

Gyrfalcon Service Manual Version 1.0

6-3

Chapter 6 Diag Operation


6.1 CE Mode Overview

6.1.5 Menu Tree


The menu tree of the CE mode is shown below.
&(0RGH

3ULQWHU'LDJ

$OO7HVW

(66'LDJ

)ODVK5207HVW
((35207HVW
'5$07HVW
0$&3+<7HVW
$6,&7HVW
,277HVW
86%+RVW7HVW
57&7HVW

7(670RGH
6LQJOH6WHS
*HW'HYLFH,QIR

H00&7HVW
1)&7HVW
,27'LDJ

'LJLWDO,QSXW
'LJLWDO2XWSXW
1906HWWLQJV
526([SRVXUH

190(GLW
6DYH190WR(66
/RDG190IURP(66

'HZ3UHYHQWLRQ
$7&0RGH
3ULQW,QIR

&RQILJ3DJH
3ULQW6HWWLQJV

,QVWDOODWLRQ6HW

6HUYLFH7DJ
6HULDO1R
+H['XPS
7RQH&RUUHFWLRQ
3L[HO&RXQWHU
&RQILJXUDWLRQ

'LS6ZLWFK
'LS6ZLWFK
'LS6ZLWFK
'LS6ZLWFK

3ULQW&RXQWHU

3ULQW6HUYLFH
&RS\6HUYLFH
)$;6HUYLFH
6FDQ6HUYLFH

&RXQWHU&RS\0WR%
&RXQWHU&RS\%WR0


7KLVLWHPLVGLVSOD\HGRQO\ZKHQWKH
190EDFNXSGDWDKDVEHHQVWRUHGE\
H[HFXWLQJ>6DYH190WR(66@
=D$.$

6-4

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.1 CE Mode Overview


190,QLW
-2%/2*,QLW
'HYLFH'DWD,QLW
1)&5)0RGH
7HVW3ULQW

7HVW3DW>,27@
*UDGDWLRQ

3DUDPHWHU

5HJL

/LIH

6ORZ6FDQ.WR3
)DVW6FDQ6PS03)
)DVW6FDQ6PS7UD\
)DVW6FDQ6PS7UD\
)DVW6FDQ'XS03)
)DVW6FDQ'XS7UD\
)DVW6FDQ'XS7UD\
)XVLQJ39
)XVLQJ+HDWWLPH
7UDQV8QLW39
'UXP39
'UXP7KLFNQHVV
:DVWH)XOO&RXQW
7RQHU'LVS7LPH
7RQHU3L[HO
7RQHU*DV*DXJH

3ULQW
&RPSOHWH



7KLVLWHPLVGLVSOD\HGRQO\ZKHQWKHRSWLRQDOWUD\LVLQVWDOOHG
=D$.$

Gyrfalcon Service Manual Version 1.0

6-5

Chapter 6 Diag Operation


6.1 CE Mode Overview


)D[6FDQQHU'LDJ

$OO7HVW

%RDUG7HVW

)D[0HPRU\7HVW

)D[)ODVK:57HVW
05$0:57HVW

,)7HVW

)D[&DUG,)7HVW
$)(6HULDO,)7HVW
,,7,)7HVW

$6,&7HVW

$6,&,-$&7HVW
$6,&-%,*7HVW

5HOD\6LJQDO7HVW

5HOD\7HVW
+RRN7HVW
6LQJOH7RQH6HQG
'70)6HQG
'LDO3XOVH6HQG
5LQJ%DFN7RQH
'DWD6HQG
/LQH9ROWDJH
/LQH&XUUHQW

,QIRUPDWLRQ

6FDQ&RXQWHU

6FDQQHU0DLQWHQDQFH

:KLWH%DODQFH

$XWR$GMXVW )%
$XWR$GMXVW '$')

6KDGLQJ3DUDPHWHU

&RHII)%5('
&RHII)%*5((1
&RHII)%%/8(
&RHII)%*5$<
&RHII'$')5('
&RHII'$')*5((1
&RHII'$')%/8(
&RHII'$')*5$<
7DUJHW5('
7DUJHW*5((1
7DUJHW%/8(
7DUJHW*5$<

5HJLVWUDWLRQ3DUDP

5HJL)%/HDG
5HJL)%6LGH
5HJL'$')/HDG )URQW
5HJL'$')6LGH )URQW
5HJL'$')/HDG %DFN
5HJL'$')6LGH %DFN
5HJL'$')/HDG )URQW'XS

$XWR5HJLVWUDWLRQ
6HQVRU3DUDPHWHU

6-6

=D$.$

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.1 CE Mode Overview


9HUWLFDO6FDQ0DJ

7HVW3DWWHUQ

0DJ)%&2/25
0DJ)%*5$<
0DJ'$')&2/25
0DJ'$')*5$<
3DWWHUQ1R

,,7,2&KHFN

+RPH3RV6HQVRU
7UD\6HQVRU
)HHG6HQVRU
'$')&RYHU6HQVRU
'$'))HHG6HQVRU
)%&RYHU6HQVRU
/DPS
)%0RWRU
'$')0RWRU
'$')6ROHQRLG

6FDQ&RXQWHU&OHDU

&RXQWHU&OHDU )%
&RXQWHU&OHDU '$')

&DUULDJH'ULYHB
3DUDPHWHU
$OO&OHDU

%DFN8S'DWD

8VHU&OHDU
6\VWHP&OHDU
8VHU 6\VWHP&OHDU
6\VWHP'DWD,QLW
'RFXPHQW&OHDU
&RPSOHWH
=D$.$

Gyrfalcon Service Manual Version 1.0

6-7

Chapter 6 Diag Operation


6.1 CE Mode Overview

6.1.6 CE Mode Functions Overview


Items available to test or execute the diagnosis in the CE mode are listed in the table below.
Printer Diag
Table 6-1 Function Names and Details (Printer)
Function

ESS Diag

Description

See

All Test

Performs all ESS Diag tests except for MAC+PHY/USB


Host/RTC.

6.2.1

FlashROM Test

Calculates the checksum per Flash ROM header area


and compares the result with the each area's prepared
checksum stored in the ROM.

6.2.2

EEPROM Test

Writes/reads/verifies the test pattern in the EEPROM


area to be evaluated.

6.2.3

DRAM Test

Writes the test data in the DRAM area to be evaluated.


(Values will be overwritten with the original value after
the test)

6.2.4

MAC+PHY Test

Performs the loopback test for MAC (Media Access


Control) and PHY (Physical Layer).

6.2.5

ASIC Test

Performs the Regi check test.

6.2.6

IOT Test

Performs the communication test between IOT.

6.2.7

USB Host Test (only


when the optional USB is
installed)

Checks the communication between a USB Host port


and the USB devices connected to the USB Host port.

6.2.8

RTC Test

Performs the RTC test.

6.2.9

eMMC Test

It implements Write/Read/Verify to the sector for the


test.

6.2.10

NFC Test

Performs the NFC test.

6.2.11

Digital Input

Checks the status of the IOT sensor.

6.3.1

Digital Output

Checks the status of the motor drive.

6.3.2

NVM Edit

IOT Diag

Print Info

SaveNVM to
NVM
ESS
Settings
LoadNVM from
ESS

Writes the NVM values.


Saves the IOT NVM information in the ESS NVM.

6.3.3

Loads all the NVM information in the ESS NVM into the
IOT.

ROS Exposure

Corrects the variation in the read-Regi of the ROS.

6.3.4

Dew Prevention

Specifies whether to set the Dew Prevention mode to


ON or OFF.

6.3.5

ATC Mode

Sets whether to enable the ATC (Automatic Toner Control) empty detection mode.

6.3.6

Config Page

Prints the printer configuration information on A4 paper.

6.4.1

Print Settings

Prints the printer setting information on A4 paper.

6.4.2

6-8

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.1 CE Mode Overview
Table 6-1 Function Names and Details (Printer)
Function

Installation Set

Service Tag

Displays/specifies the value of the service tag.

Serial No.

Displays/specifies the serial number.

HexDump

Specifies whether to set HexDump to ON or OFF.

Tone Correction
(IOT tone correction)

Specifies whether to set IOT Tone Correction to ON or


OFF.

Pixel Counter

Displays the pixel count of the last page.

Configuration

Operates the DIP switches on the NVM in ESS.

Print
Counter

Print Service

Displays the current count of the Print Service.

Copy Service

Displays the current count of the Copy Service.

FAX Service

Displays the current count of the FAX Service.

Scan Service

Displays the current count of the Scan Service.

Complete

See

6.5

Counter Copy M to B

Copies the Master NVM values to the Backup NVM.

Counter Copy B to M

Copies the Backup NVM values to the Master NVM.

NVM Init

Initializes NVM.

JOB LOG Init

Initializes the job data (log).

Dvice Data Init

Deletes all data in the devices (EEPROM, MRAM, Fax


Memory, eMMC).

NFC RF Mode

It executes the diagnosis of NFC Reader/Writer.

Test Pat 600 [IOT]

Prints the IOT built-in test pattern 600dpi. (checks the


printing function of the IOT)

Gradation

Prints the pattern containing patches of different densities ranging from 0 through 100%. (ESS built-in test pattern)

Regi

Displays/specifies the Regi current set value.

6.7.1

Life

Displays the current counter of the consumables life.

6.7.2

Print

Prints the parameter of the IOT and the error count.

6.7.3

Complete

Exits the CE mode and restarts the printer.

6.1.4

Test Print

Parameter

Description

Gyrfalcon Service Manual Version 1.0

6-9

6.6

Chapter 6 Diag Operation


6.1 CE Mode Overview
Fax/Scanner Diag
Table 6-2 Function Names and Details (Fax/Scanner)
Function

Continually performs the Fax Memory, Fax Card I/F,


AFE Serial I/F, IIT I/F, and ASIC tests.

All Test
Fax
Memory Test

Fax Flash W/R


Test

Performs write/read tests of the Fax Flash Memory.

SRAM W/R
Test

Performs write/read tests of the Fax SRAM.

6.8.1

6.8.2

Performs the communication test between Fax Card,


AFE, and IIT.

6.8.3

ASIC Test

Performs the ASIC built-in IJAC/JBIG test.

6.8.4

Relay/
Signal
Test

Relay Test

Toggles the Relay signal at the specified frequency.

Hook Test

Toggles the Hook signal at the specified frequency.

Single Tone
Send

Continuously sends the tone at the selected frequency.

DTMF Send

Continuously sends the DTMF signal.

Dial Pulse
Send

Sends the multi-digits Dial Pulse (10/20pps) signal.

Ring Back
Tone

Sends the ringback tone.

Data Send

Specifies the speed and pattern for checking data forwarding (no pattern for V.34)

Line Voltage

Checks the status of the Line Voltage.

Line Current

Checks the status of the Line Current.

Information Scan Counter

Parameter

See

I/F Test

Board Test
(Board
Diag)

Scanner
Maintenance

Description

6.8.5

Displays the Scan counter value.

6.9.1

White Balance

Adjusts the white balance automatically.

6.10.1

Shading Parameter

Specifies the Shading factor setting.

6.10.2

Registration Param.

Adjusts the Registration.

6.10.3

Auto Registration

Specifies whether the Auto Reg adjust function to set to


ON or OFF.

6.10.4

Sensor Parameter

Specifies the power control value of the Feed Sensor.

6.10.5

Vertical Scan Mag.

Specifies the parameter setting of the magnification for


the vertical scanning.

6.10.6

Test Pattern

Specifies the test pattern and the parameter setting.

6.10.7

IIT I/O Check

Checks the input and output of the scanner components.

6.10.8

Scan Counter Clear

Clear the scan counter.

6.10.9

Carriage Drive_100

The carriage continuous motion.

6.10.10

Specifies the system data setting using ChainLink.

6-10

6.11

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.1 CE Mode Overview
Table 6-2 Function Names and Details (Fax/Scanner)
Function

Backup
Data

Complete

Description

All Clear

Deletes the SRAM/EEPROM backup data.

User Clear

Deletes the SRAM/EEPROM backup data.

Sysytem Clear

Deletes the SRAM/EEPROM backup data.

User&Sysytem Clear

Deletes the SRAM/EEPROM backup data.

System Data Init

Deletes the SRAM/EEPROM backup data.

Document Clear

Deletes the document data in the Fax Flash Memory.

Complete

Exits the CE mode and restarts the printer.

Gyrfalcon Service Manual Version 1.0

6-11

See

6.12

6.1.4

Chapter 6 Diag Operation


6.2 ESS Diag

6.2 ESS Diag


This section explains the details of the ESS Diag test results.

6.2.1 ALL Test


All Test allows you to execute a series of Flash ROM, EEPROM, DRAM, ASIC, and IOT tests in one go.
(MAC+PHY/PANEL/USB Host/RTC tests are not carried out.)
Table 6-3 All Test
Display After Diag
Normal

Error

CHECK OK

*** Error

Note
***: Displays the name of the test ended in error.
(Flash ROM / EEPROM / DRAM / ASIC / IOT)

Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

CE Mode
* Printer Diag
FAX/Scanner Diag

Printer Diag
ESS Diag

Press the [OK] button.

Printer Diag
ESS Diag

ESS Diag
All Test

Press the [OK] button.

All Test
Start

6-12

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.2 ESS Diag
5

Press the [OK] button to start the test.

All Test
Processing

All Test
CHECK OK

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
ESS Diag

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

6.2.2 Flash ROM Test


Flash ROM Test calculates the checksum per Flash ROM header area and compares the result with the each
area's checksum prepared in ROM. The status will be regarded as normal when the all results coincide with
the checksums stored in ROM.
Table 6-4 FlashROM Test
Display After Diag
Normal

Error

CHECK OK

FlashROM ERROR xxxxxx

6.2.3 EEPROM Test


EEPROM Test allows you to execute read/write/verify of the test pattern (0xff, 0xaa, 0x55, 0x00) from the
head of the EEPROM for one byte in every 0 x 400.
Table 6-5 EEPROM Test
Display After Diag
Normal

Error

CHECK OK

EEPROM ID* ERROR


(*: ID number of the EEPROM)

Gyrfalcon Service Manual Version 1.0

6-13

Chapter 6 Diag Operation


6.2 ESS Diag

6.2.4 DRAM Test


DRAM Test checks whether the writing of the test data, 4-byte unit (0x00000000 -> 0x55555555 ->
0xaaaaaaaa -> 0xffffffff -> 0x00000000 -> ...), in the area available for the diagnosis is possible or not.
Values will be overwritten with the original value after the test.
Area available for the diagnosis: Work areas other than the stack area and the task acquiring area.
Table 6-6 DRAM Test
Display After Diag
Normal

Error

CHECK OK

DRAM slot* ERROR (*: 0, 1)


(*: 0 = Standard memory, 1 = Optional memory)

6.2.5 MAC+PHY Test


MAC+PHY Test allows you to perform the loopback test for MAC (Media Access Control) and PHY (Physical
Layer).
Table 6-7 MAC+PHY Test
Display After Diag
Normal

Error

CHECK OK

MAC+PHY ERROR

6.2.6 ASIC Test


ASIC Test reads the device ID of the REMORA-EX via ZoranQuatro4530 and performs the Zoran Quatro4530
and REMORA-EX tests.
Table 6-8 ASIC Test
Display After Diag
Normal

Error

CHECK OK

ASIC CHECK NG

6-14

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.2 ESS Diag

6.2.7 IOT Test


IOT Test provides the communication test between the IOT. In this communication test, the IOT status register is read for checking whether the commands are exchanged normally.
Table 6-9 IOT Test
Display After Diag
Normal

Error

CHECK OK

IOT ERROR

6.2.8 USB Host Test


USB Host Test checks the communication between a USB Host port and the USB devices connected to the
USB Host port.
* This test menu is for obtaining the USB authentication. To use this test, you will need the devices approved
by the certification authority.

6.2.8.1 TEST MODE


Table 6-10 Test Mode (when the optional USB Host is installed)
Item

TEST MODE

Description

TEST J

Keeps J state for the DownStream port of the Host Controller.

TEST K

Keeps K state for the DownStream port of the Host Controller.

TEST SE0

Keeps SE0 state for the DownStream port of the Host Controller.

TEST PACKET

Repeatedly sends the test packet form the DownStream port of the
Host Controller.

TEST ENABLE

Forcefully keeps the port in the "ENABLE" status.

NOTE
To complete the test mode, restart the printer.

Gyrfalcon Service Manual Version 1.0

6-15

Chapter 6 Diag Operation


6.2 ESS Diag
6.2.8.2 Single Step
Single Step allows you to collect Device Descriptor from the device you specify.
Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Press the [OK] button.

Printer Diag
ESS Diag

ESS Diag
All Test

Use the [ ] button to select [USB Host Test], and press the [OK] button.

ESS Diag
USB Host Test

USB Host Test


TEST MODE

Use the [ ] button to select [Single Step], and press the [OK] button.

USB Host Test


Single Step

Single Step
Address: 000

Specify the device address. (Available addresses are 0 to 127.)


Use the [ ] and [ ] buttons to move the cursor to right and left.
Use the [ ] and [ ] buttons to increase or decrease the value where the cursor is placed.

Single Step
Address: 002

Cursor
7

Press the [OK] button to transfer a request to the device specified.

Single Step
DATA IN

Single Step
Address: 002

Press the [OK] button to obtain data from the device specified.

[CHECK OK] will appear when the data is obtained normally.

6-16

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.2 ESS Diag
When the data is not obtained normally, [CHECK NG] will appear, and when the request was
not transferred to the device, [Send Error] will appear.

Single Step
CHECK OK
10

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
ESS Diag

11

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

6.2.8.3 Get Device Info


Get Device Info displays the VID, PID, Add, and Prt information of the device connected. [Read Error] will
appear when the device information is not obtained.
VID: [Vendor ID] value of a device collected by the Device Descriptor
PID: [Product ID] value of a device collected by the Device Descriptor
Add: [Device Address] assigned to the device
Prt: The port number of a connected controller or the downstream port number of the hub

Gyrfalcon Service Manual Version 1.0

6-17

Chapter 6 Diag Operation


6.2 ESS Diag

6.2.9 RTC Test


RTC Test checks the time by backing up the current time and writing the default values, and then checking,
after a certain period of time, whether the time reaches the expected time.
* Performing RTC Test will delay the internal clock of the printer by 2 seconds.
Table 6-11 RTC Test
Display After Diag
Normal

Error

CHECK OK

RTC ERROR

6.2.10 eMMC Test


It implements Write/Read/Verify to the sector for the test.
In this, in case of the error, the eMMC use becomes impossible.
Table 6-12 eMMC Test
Display After Diag
Normal

Error

CHECK OK

eMMC ERROR

6.2.11 NFC Test


It executes the diagnosis of NFC Reader/Writer.
It processes a diagnosis using the Diagnose command of the PN532 chip.
The diagnosis contents are as the following.
Communication Line Test (The test of the communication between the driver and PN532)
ROM Test (The checksum of the ROM of PN532)
RAM Test (The RAM writing in check of PN532)
Self Antenna Test (The continuity check of the antenna send-line)

Table 6-13 NFC Test


Display After Diag
Normal

Error

CHECK OK

NFC ERROR

6-18

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.3 IOT Diag

6.3 IOT Diag


6.3.1 Digital Input
Digital Input checks whether the digital input (DI) components function properly.
The display shows [0] when the digital input test is started, and the value will be increased when the DI components are switched from OFF to ON, which is used for confirming that the component functions normally.
The test targets all DI components.

Table 6-14 Digital Input Test Parameter Table


Chain

Link

Component

010

200

Fusing Relay Enable

010

201

Envelope Mode Sensor Side D

010

202

Envelope Mode Sensor Side AD

041

300

Inter Lock Front Cover

041

301

Inter Lock Rear Cover

042

200

Rear Fan Alarm

042

201

LVPS Fan Alarm

071

100

MSI No Paper Sensor

071

101

Tray 1 No Paper Sensor [CST No Paper Sensor]

071

102

Regi Sensor

071

103

Exit Sensor

071

116

Option Feeder 1 No Paper Sensor

071

200

Option Feeder 1 Motor Alarm

Digital Input Test Example


This section explains Digital Input Text using [041-302: Front Cover Sensor] as an example.
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [IOT Diag], and press the [OK] button.

Printer Diag
IOT Diag

Gyrfalcon Service Manual Version 1.0

IOT Diag
Digital Input

6-19

Chapter 6 Diag Operation


6.3 IOT Diag
4

Press the [OK] button.

IOT Diag
Digital Input

Digital Input
010 - 200
OFF

Use the [ ] or [ ] button to select [041-300].

Digital Input
041-300
OFF

Press the [OK] button.

Digital Input
041-300 L 00

Open and shut the front cover to check that the display changes as shown below.
Cover Open

Cover Close

Digital Input
041-300 H 00

Digital Input
041-300 L 01

Press the [<--] (Back) button to stop the test.

Digital Input
041-300
OFF

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
IOT Diag

10

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

6-20

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.3 IOT Diag

6.3.2 Digital Output


Digital Output checks whether the digital output (DO) components function properly.
You can switch each DO component to ON and check the operation separately, which helps you judge which
component functions normally.
You can operate all components at one time in the Digital Output Test. If you open the interlock while a motor
test is being executed, the operation of each component will be stopped.

NOTE
Except for 010-001, 042-001, 042-002, and 042-003, set LVPS 24V (041-001) to ON (EXEC). Otherwise,
the component does not operate.

Table 6-15 Digital Output Test Parameter Table


Chain

Link

010

001

Fusing Relay

041

001

Low Voltage Power Supply 24V

042

001

Rear Fan (Normal)

042

002

Rear Fan (Half)

042

003

LVPS Fan

061

001

ROS Motor [Motor Polygon ASSY]

071

001

Main Motor [DRIVE ASSY MAIN] (Normal)

071

002

Main Motor [DRIVE ASSY MAIN] (Half)

071

003

Main Motor [DRIVE ASSY MAIN] (Low)

071

004

MSI Feed Solenoid [SOLENOID FEED MSI] (Auto OFF)

071

005

Tray 1 Feed Clutch [CST FEED CLUTCH]

071

006

Regi Clutch

071

007

Exit Clutch [CLUTCH ASSY EXIT]

071

008

Exit Invert Clutch [CLUTCH ASSY INVERT]

071

009

Option Feeder 1 Motor [MOTOR ASSY OPTION] (Normal)

071

010

Option Feeder 1 Motor [MOTOR ASSY OPTION] (Half)

071

011

Option Feeder 1 Motor [MOTOR ASSY OPTION] (Low)

071

018

Option Feeder 1 Feed Clutch [CLUTCH ASSY OPT


FEED] (Auto OFF)

093

001

Toner Dispense Motor [MOTOR DISP] (Normal)

093

002

Toner Dispense Motor [MOTOR DISP] (Half)

Gyrfalcon Service Manual Version 1.0

Component

6-21

Chapter 6 Diag Operation


6.3 IOT Diag
Digital Output Test Example
This section explains Digital Output Text using a flow of checking [071-002: Main Motor (Half)] and
[071-006: Regi Clutch] as an example.
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [IOT Diag], and press the [OK] button.

Printer Diag
IOT Diag

IOT Diag
Digital Input

Use the [ ] button to select [Digital Output], and press the [OK] button.

IOT Diag
Digital Output

Digital Output
010-001 READY

To set LVPS 24V to On, use the [ ] or [ ] button and select [041-001].

Digital Output
041-001 READY

Press the [OK] button, and check the operation sound.

Digital Output
041-001 EXEC

To carry on checking the operation of Main Motor (Half), do not press the [<--] (Back) button. Use
the [ ] or [ ] button to display [071-002].

Digital Output
071-002 EXEC

Press the [OK] button, and check the operation sound.

Digital Output
071-002 EXEC

6-22

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.3 IOT Diag
NOTE
Press the [<--] (Back) button to stop the test.
9

To carry on checking the operation of Regi Clutch, do not press the [<--] (Back) button. Use the
[ ] or [ ] button to display [071-010].

Digital Output
071-006 READY

10

Press the [OK] button, and check the operation sound.

Digital Output
071-006 EXEC

11

Press the [<--] (Back) button to stop the Regi Clutch operation.

Digital Output
071-006 READY

12

To stop the Main Motor (Half) operation, use the [ ] button to select [071-002], and then press
the [<--] (Back) button.

Digital Output
071-002 READY

13

To set LVPS 24V to Off, use the [ ] button and select [041-001], and then press the [<--] (Back)
button.

Digital Output
041-001 READY

14

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
IOT Diag

15

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

Gyrfalcon Service Manual Version 1.0

6-23

Chapter 6 Diag Operation


6.3 IOT Diag

6.3.3 NVM Settings


You can access to the NVM (IOT EEPROM) using the keys on the touch panel.
The following functions are provided.
Reading and writing of the data in the IOT NVM
Saving the IOT NVM information to ESS
Returning all NVM information saved in ESS to the IOT NVM
Table 6-16 NVM of Adjustment Features
Chain

742

746

746

746

746

Link

516

020

NVM Name

BTR CAN mode


switch

Toner discharge
mode switch

021

Electrostatic
memory action
mode switch

022

Pre-exposure
mode

026

ATC empty
detection switch

Range

0, 1

0, 1

0, 1

0, 1

0, 1

Default
Value

Description

BTR CLN mode switch (0: Off, 1: On)


When performing this, change the value to [1],
and then restart the printer.
The IOT performs BTR cleaning after restart. The
data is automatically reset to [0] after the test.

Toner discharge mode switch (0: Off, 1: On)


When performing this, change the value to [1],
and then restart the printer. The IOT executes
toner discharge after restart. The data is automatically reset to [0] after the test.

Electrostatic memory action mode switch (0: Off,


1: On)
When performing this, change the value to [1],
and then restart the printer. The IOT operates in
the electrostatic memory action mode after
restart.

Pre-exposure mode (0: Off, 1: On)


When performing this, change the value to [1],
and then restart the printer. The IOT goes into the
pre-exposure mode after restart.

ATC empty detection switch (0: On, 1: Off)


When performing this, change the value to [0],
and then restart the printer. The IOT operates in
the ATC empty detection mode after restart.

6-24

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.3 IOT Diag
6.3.3.1 NVM Read and Write (NVM Edit)
NVM Edit allows you to read or write the IOT NVM.

NVM Read and Write (NVM Edit) is for changing settings peculiar to the device, and therefore requires
you a precise attention, otherwise you might lose the essential setting of the printer or give the printer an
unrecoverable failure.
Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [IOT Diag], and press the [OK] button.

Printer Diag
IOT Diag

IOT Diag
Digital Input

Use the [ ] button to select [NVM Settings], and press the [OK] button.

IOT Diag
NVM Settings

NVM Settings
NVM Edit

Press the [OK] button.

Enter the Chain-Link number.


Use the [ ] and [ ] buttons to move the cursor to right and left.
Use the [ ] and [ ] buttons to increase or decrease the value where the cursor is placed.
NVM Edit
CL No.000-000

Cursor
7

Press the [OK] button to confirm the Chain-Link number.


When there is a relevant Chain-Link No., the screen displays the current NVM value and the
cursor.

Gyrfalcon Service Manual Version 1.0

6-25

Chapter 6 Diag Operation


6.3 IOT Diag
When there is no relevant Chain-Link No., the screen displays NG. In this case,
press the [<--] (Back) button to enter the Chain-Link No. again.

742-516
+00000000001*

008-002
Number NG

Specify the NVM value.


Use the [ ] and [ ] buttons to move the cursor to right and left.
Use the [ ] and [ ] buttons to increase or decrease the value where the cursor is placed.

742-516
+00000000011*

Cursor

Press the [OK] button to start writing the new NVM value.

742-516
+0000000001

10

Press the [<--] (Back) button to return to the previous screen.

NVM Edit
Please Wait

11

NVM Settings
NVM Edit

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
IOT Diag

12

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

6-26

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.3 IOT Diag
6.3.3.2 NVM Saving (SaveNVM to ESS)
SaveNVM to ESS allows you to save the IOT NVM information to ESS.

NOTE
If the IOT NVM information has never been changed using [Edit NVM}, [Save NVM to ESS] cannot be executed.

Procedure
1

Enter the CE mode to select [IOT Diag] > [NVM Settings], and press the [OK] button.
(See "6.1.2 How To Enter the CE Mode".)

IOT Diag
NVM Settings

NVM Settings
NVM Edit

Use the [ ] button to select [SaveNVM to ESS], and press the [OK] button.

NVM Settings
SaveNVM to ESS

SaveNVM to ESS
OK?

Press the [OK] button.

SaveNVM to ESS
Processing

SaveNVM to ESS
Saved

Press the [<--] (Back) button to return to the [Printer Diag] screen, and then exit the CE mode.
(See "6.1.4 How to Exit the CE Mode".)

Gyrfalcon Service Manual Version 1.0

6-27

Chapter 6 Diag Operation


6.3 IOT Diag
6.3.3.3 NVM Loading (LoadNVM from ESS)
LoadNVM from ESS allows you to load all NVM information saved in LESS to the IOT NVM.

Do not execute "NVM Loading" unless "NVM Saving" has been executed. Doing so will damage PWBA
MCU.

Procedure
1

Enter the CE mode to select [IOT Diag] > [NVM Settings], and press the [OK] button.
(See "6.1.2 How To Enter the CE Mode".)

IOT Diag
NVM Settings

NVM Settings
NVM Edit

Use the [ ] button to select [Initialize Slave], and press the [OK] button.

NVM Settings
LoadNVM from ESS

LoadNVM from ESS


OK?

Press the [OK] button.

LoadNVM from ESS


Processing

LoadNVM from ESS


Loaded

Press the [<--] (Back) button to return to the [Printer Diag] screen, and then exit the CE mode.
(See "6.1.4 How to Exit the CE Mode".)

6-28

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.3 IOT Diag

6.3.4 ROS Exposure


ROS Exposure corrects the ROS read registration when it has variation.
Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and press the [OK] button.

Use the [ ] button to select [IOT Diag], and press the [OK] button.

Printer Diag
IOT Diag

IOT Diag
Digital Input

Use the [ ] button to select [ROS Exposure], and press the [OK] button.

IOT Diag
ROS Exposure

ROS Exposure
Auto Correct

Press the [OK] button.

Auto Correct
OK?

Press the [OK] button.

Auto Correct
Processing

Auto Correct
Corrected

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
IOT Diag

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

Gyrfalcon Service Manual Version 1.0

6-29

Chapter 6 Diag Operation


6.3 IOT Diag

6.3.5 Dew Prevention


You can specify whether to set the Dew Prevention mode to ON or OFF.
OFF: Switches to the Sleep mode in the normal mode.
ON: Does not switch to the Sleep mode in the normal mode.
Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [IOT Diag], and press the [OK] button.

Printer Diag
IOT Diag

IOT Diag
Digital Input

Use the [ ] button to select [Dew Prevention], and press the [OK] button.

IOT Diag
Dew Prevention

Dew Prevention
OFF *

Use the [ ] or [ ] button to switch to ON or OFF, and press the [OK] button.

Dew Prevention
ON

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
IOT Diag

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

6-30

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.3 IOT Diag

6.3.6 ATC Mode


Sets whether to enable the ATC (Automatic Toner Control) empty detection mode.
ON: Changes the toner cartridge detection method to the count method.
OFF: Changes the toner cartridge detection method to the ATC method.
Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [IOT Diag], and press the [OK] button.

Printer Diag
IOT Diag

IOT Diag
Digital Input

Use the [ ] button to select [ATC Mode], and press the [OK] button.

IOT Diag
ATC Mode

ATC Mode
OFF*

Use the [ ] or [ ] button change the ON/OFF setting, and press the [OK] button for confirmation.

ATC Mode
ON

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
IOT Diag

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

Gyrfalcon Service Manual Version 1.0

6-31

Chapter 6 Diag Operation


6.4 Print Info

6.4 Print Info


6.4.1 Printing Printer Configuration Report (Config Page)
You can print the following printer configuration information (A4 size paper is supported).
IOT Installed Tray
IOT ROM Version
IOT Duplex Unit (Option)
Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [Print Info], and press the [OK] button.

Printer Diag
Print Info

Print Info
Config Page

Press the [OK] button.

Print Info
Config Page

Config Page
Ready

Press the [OK] button to print the printer configuration report.


The screen will return to the [Ready] screen after print.

Config Page
Processing

Config Page
Ready

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
Print Info

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

6-32

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.4 Print Info

6.4.2 Printing Printer Settings Report (Print Settings)


You can print the following printer settings report (A4 size paper is supported).
Service Tag
Express Service Code
Serial No.
HexDump ON/OFF Information
IOT Tone Correction ON/OFF Information
Print B/W Count
Print B/W BackUp Count
Print B/W Error Count
Copy B/W Count
Copy B/W BackUp Count
Copy B/W Error Count
FAX B/W Count
FaxToSMB and FaxToFTP Page Count
FaxToEmail Page Count
FAX B/W BackUp Count
FaxToSMB and FaxToFTP Page BackUp Count
FaxToEmail Page BackUp Count
FAX B/W Error Count
FaxToSMB and FaxToFTP Page Error Count
FaxToEmail Page Error Count
ScanToSMB and ScanToFTP Page Count
ScanToEmail Page Count
ScanToServer Page BackUp Count
ScanToEmail Page BackUp Count
ScanToServer Page Error Count
ScanToEmail Page Error Count

Gyrfalcon Service Manual Version 1.0

6-33

Chapter 6 Diag Operation


6.4 Print Info
Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [Print Info], and then select the [OK] button.

Printer Diag
Print Info

Print Info
Config Page

Use the [ ] button to select [Print Settings], and press the [OK] button.

Print Info
Print Settings

Print Settings
Ready

Press the [OK] button to print the printer setting information.


The screen will return to the [Ready] screen after print.

Print Settings
Processing

Print Settings
Ready

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
Print Info

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

6-34

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.5 Installation Settings (Installation Set)

6.5 Installation Settings (Installation Set)


Set the parameter as indicated in the table below.
Table 6-17 Installation Settings
Item

Range

Description

Service Tag

7 digits

Displays or changes the 7 digits service tag


value.

Serial No.

9 digits

Displays or changes the 9 digits serial number.

HexDump

ON,OFF

Specifies whether HexDump to set to ON or


OFF.

Tone Correction (IOT tone control)

ON,OFF

Specifies whether IOT Tone Correction to set


to ON or OFF.

0-100%

Displays the pixel count of the last page.


Displays the ESS-ASIC based pixel count of
the last page printed, as a coverage ratio
with respect to the area 4 mm inside all
sides of A4.
The value is rounded off to the first decimal
place.

Pixel Counter

Dip Switch 0
Configuration

Dip Switch 1

Operates the DIP switches on the NVM in


ESS.

B/W
B/W print counter

Displays the current value of the following


counters.
B/W print count in the normal mode
B/W print count in the toner saver mode
Report print count

B/W Backup
Backup B/W print counter

Displays the backup value of the B/W print


counter.

B/W Error
B/W print error counter

Displays the number of auto-recoveries performed when the value of the B/W print
counter is different from that of the Backup B/
W print counter.

B/W
B/W copy counter

Displays the value of the B/W copy counter.

B/W Backup
Backup B/W copy counter

Displays the backup value of the B/W copy


counter.

Displays the number of auto-recoveries performed when the value of the B/W copy
counter is different from that of the Backup B/
W copy counter.

Dip Switch 2
Dip Switch 3

Print Counter
(Print Service)

Print Counter
(Copy Service)

B/W Error
B/W copy error counter

Gyrfalcon Service Manual Version 1.0

6-35

Chapter 6 Diag Operation


6.5 Installation Settings (Installation Set)
Table 6-17 Installation Settings
Item

Range

Description

B/W
Monochrome fax reception
counter

Displays the count of the monochrome FAX


received.

B/W Backup
Monochrome fax reception counter backup

Displays the count backup of the monochrome


FAX received.

B/W Error
Monochrome fax reception
error counter

Displays the number of auto-recoveries performed when the number of the FAX received
is different from the count backup.

SMB/FTP
SMB/FTP counter

Displays the count of pages transferred via


Scan To SMB and Scan To FTP.

Email
Email counter

Displays the count of pages transferred via


Scan To Email.

SMB/FTP Backup
SMB/FTP counter backup

Displays the SMB/FTP count backup.

Email Backup
Email counter backup

Displays the Email count backup.

SMB/FTP Error
SMB/FTP error counter

Displays the number of auto-recoveries performed when the number of SMB/FTP count is
different from the count backup.

Email Error
Email error counter

Displays the number of auto-recoveries performed when the number of E-mail count is
different from the count backup.

Copies from the ESS Master NVM to the


Backup NVM.
The following items are copied:
"Personal Info", device-specific information
stored in the first 128 Bytes
PV counter master
Printer counter master
AIO counter master

Counter Copy B to M

Copies from the ESS Backup NVM to the


Master NVM.
The following items are copied:
"Personal Info", device-specific information
stored in the first 128 Bytes
PV counter master
Printer counter master
AIO counter backup

NVM Init

Initializes NVM
(ESS NVM all delete ( = 0 clear))

JOB LOG Init

Initializes the job data (log)


(JobHistory data deletion ( = 0 clear))

Print Counter
(FAX Service)

Print Counter
(Scan Service)

Counter Copy M to B

6-36

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.5 Installation Settings (Installation Set)
Table 6-17 Installation Settings
Item

Device Data Init

Range

Description

Error Log

Deletes the E2PROM Error Log data.

Jam Log

Deletes the E2PROM Jam Log data.

Job Log

Deletes the E2PROM Job Log data.

FW Parameter

Deletes the E2PROM FW Parameter data.

NET Parameter

Deletes the E2PROM NET Parameter data.

Auditron/PV

Deletes the E2PROM Auditron/each users


Print Volume data.

MRAM Adrs

Deletes the MRAM address data.

FAX Log

Deletes the FAT data in the Fax System Data


File System of the SRAM/Fax Memory, and it
also deletes all files via the File System.

eMMC

Deletes the eMMC data.

Erase Complete

Normal-end.

NFC RF Mode

Gyrfalcon Service Manual Version 1.0

ON,OFF

6-37

Specifies whether NFC RF Mode to set to ON


or OFF.

Chapter 6 Diag Operation


6.5 Installation Settings (Installation Set)
Serial Number Setting (Serial No.)
The procedure below explains how to change the parameter using [Serial No.] as an example.
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [Installation Set], and press the [OK] button.

Printer Diag
Installation Set

Installation Set
Service Tag

Use the [ ] button to select [SerialNo.], and press the [OK] button.

Installation Set
SerialNo.

Serial No.
000000000 *

Change the serial number.


Use the [ ] and [ ] buttons to move the cursor to right and left.
Use the [ ] and [ ] buttons to increase or decrease the value where the cursor is placed.
The asterisk (*) will disappear when the number is changed from the current number.

Serial No.
000000000 *

Serial No.
000000001

Cursor

Press the [OK] button.


The number changed will be written in and the screen returns to the previous screen.

Installation Set
SerialNo.

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
Installation Set

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

6-38

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.6 Print Function Test (Test Print)

6.6 Print Function Test (Test Print)


You can perform the Test Print using the prepared patterns for the print test. In the event of paper jam or out
of paper, wait until the error is released.
NOTE
Do not remove the cassette while the test is being executed. Before the print test, check that the paper tray
contains enough paper.

6.6.1 Procedure for the Print Function Test


This section describes how to perform a test print using the gradation pattern as an example.
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that [Printer Diag] is selected, and press the [OK] button.

Use the [ ] button to select [Test Print], and press the [OK] button.

Printer Diag
Test Print

Test Print
TestPat600 [IOT]

Use the [ ] button to select [Gradation], and press the [OK] button.

Test Print
Gradation

Gradation
Ready

Press the [OK] button to print the test pattern.


The screen will return to the [Ready] screen after print.

Gradation
Processing

Gradation
Ready

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
Test Print

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

Gyrfalcon Service Manual Version 1.0

6-39

Chapter 6 Diag Operation


6.6 Print Function Test (Test Print)

6.6.2 Test Pattern (Test Pat 600 [IOT])


The Test Pat 600 [IOT] Test Pattern prints the IOT built-in test pattern 600 dpi on a side of paper (IOT print
functionality check).

ZaS060601AA

6-40

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.6 Print Function Test (Test Print)

6.6.3 Gradation
The Gradation (ESS built-in test pattern) prints the broken border patterns with the density of 0 to 100%.

ZaS060602AA

Gyrfalcon Service Manual Version 1.0

6-41

Chapter 6 Diag Operation


6.7 Parameter Setting (Parameter)

6.7 Parameter Setting (Parameter)


Use Parameter to read and write the parameters in the IOT parameters.

6.7.1 Registration Parameter Settings (Regi)


Displays or changes the registration adjustment values currently set.
Table 6-18 Registration Parameter
Item

Regi

Range

Description

Slow Scan K to P

-15 to +15

Displays or changes the registration adjustment values of Slow Scan K to P.

Fast Scan Smp MPF

-15 to +15

Displays or changes the registration adjustment values of Fast Scan Smp MPF (MSI).

Fast Scan Smp Tray1

-15 to +15

Displays or changes the registration adjustment values of Fast Scan Smp Tray 1
(Standard Tray).

Fast Scan Smp Tray2


(when Tray2 is installed)

-15 to +15

Displays or changes the registration adjustment values of Fast Scan Smp Tray 2
(Optional Tray).

Fast Scan Dup MPF

-15 to +15

Displays or changes the registration adjustment values of Fast Scan Dup MPF (MSI).

Fast Scan Dup Tray1

-15 to +15

Displays or changes the registration adjustment values of Fast Scan Dup Tray 1
(Standard Tray).

Fast Scan Dup Tray2


(when Tray2 is installed)

-15 to +15

Displays or changes the registration adjustment values of Fast Scan Dup Tray 2
(Optional Tray).

Procedure
The following procedure explains how to change the registration value using [Fast Scan Smp MPF] as an
example.
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [Parameter], and press the [OK] button.

Printer Diag
Parameter

Parameter
Regi

6-42

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.7 Parameter Setting (Parameter)
4

Press the [OK] button.

Parameter
Regi

Regi
SlowScan KtoP

Use the [ ] button to select [FastScanSmp MPF], and press the [OK] button.

FastScanSmp MPF
0 *

Regi
FastScanSmp MPF

Use the [ ] or [ ] button to change the value, and press the [OK] button.

FastScanSmp MPF
-2

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
Parameter

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

Gyrfalcon Service Manual Version 1.0

6-43

Chapter 6 Diag Operation


6.7 Parameter Setting (Parameter)

6.7.2 Life Counter Display and Counter Initialization (Life)


You can display the life counter of the IOT and initialize the life counter value.
Table 6-19 Life Counter
Item

Life

Description

Fusing PV

Displays and initializes the life counter value of Fusing PV.

Fusing Heattime

Displays and initializes the life counter value of Fusing Heattime.

Trans Unit PV

Displays and initializes the life counter value of Trans Unit.

Drum PV

Displays the life counter value of Drum PV.

Drum Thickness

Displays the life counter value of Drum Thickness.

Waste Full Count

Displays the life counter value of Waste Full Count.

Toner Disp Time

Displays the life counter value of Toner Disp Time.

Toner Pixel

Displays the life counter value of Toner Pixel.

Toner Gas Gauge

Displays the life counter value of Toner Gas Gauge.

Procedure
The following procedure describes how to change the life counter value of Fusing Heattime as an example.
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [Parameter], and press the [OK] button.

Printer Diag
Parameter

Parameter
Regi

Use the [ ] button to select [Life], and press the [OK] button.

Parameter
Life

Life
Fusing PV

Use the [ ] button to select [Fusing Heattime], and press the [OK] button.

Life
Fusing Heattime

Fusing Heattime
Reading

6-44

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.7 Parameter Setting (Parameter)
6

Press the [OK] button to display the value.

Fusing Heattime
38

To initialize the life counter value of Fusing Heattime, press the [<--] (Back) button to return to the
level immediately previous to the level where you displayed the value, use the [ ] button to
select [Initialize], and then select the [OK] button.

Fusing Heattime
Reading

Fusing Heattime
Initialize

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
Parameter

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

Gyrfalcon Service Manual Version 1.0

6-45

Chapter 6 Diag Operation


6.7 Parameter Setting (Parameter)

6.7.3 Parameter List Print (Print)


You can print the values of the parameter of the IOT, the error count, and the life count.

When you print the parameter list, check that the Tray 1 contains A4 paper (Only A4 paper is supported). If
the parameter list is printed on the paper of other than A4, some part of the image might be lost.
The printer will display [Processing] and suspend the parameter list from printing, if the paper size other
than A4 is set as the default paper tray setting.
In this case, switch off the printer once, and on again, specify A4 for the paper tray setting, enter the CE
mode, and then print the list.

Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Confirm that the [Printer Diag] is selected, and then press the [OK] button.

Use the [ ] button to select [Parameter], and then press the [OK] button.

Printer Diag
Parameter

Parameter
Regi

Use the [ ] button to select [Print], and press the [OK] button.

Parameter
Print

Print Parameter
Ready

Press the [OK] button to print the parameter list.


The screen will return to the [Ready] screen when the parameter list print is complete.

Print Parameter
Processing

Print Parameter
Ready

Press the [<--] (Back) button to return to the [Printer Diag] screen.

Printer Diag
Parameter

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

6-46

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.8 Board Diag (Board Test)

6.8 Board Diag (Board Test)


This section explains the details of the Board Diag.

6.8.1 All Test


All Test allows you to execute a series of Fax Memory, Fax Card I/F, AFE Serial I/F, IIT I/F, ASIC in one go.
Table 6-20 All Test
Display After Diag
Normal

Error

CHECK OK

*** Test Check NG

Note
***: Displays the name of the test ended in error.
(Fax Flash W/R / SRAM W/R / Fax Card I/F / AFE Serial I/F /
IIT I/F/ ASIC IJAC / ASIC JBIG)

6.8.2 Fax Memory Test


Fax Memory Test allows you to check the read and write ability of the Fax memory.
Table 6-21 All Test
Display After Diag
Normal

Error

CHECK OK

*** Test Check NG

Note
***: Displays the name of the test ended in error.
(Fax Flash W/R / SRAM W/R)

6.8.3 I/F Test


I/F Test provides the communication test between Fax Card, AFE Serial I/F, and IIT.
Table 6-22 All Test
Display After Diag
Normal

Error

CHECK OK

*** Test Check NG

Gyrfalcon Service Manual Version 1.0

Note
***: Displays the name of the test ended in error.
(Fax Card I/F / AFE Serial I/F / IIT I/F)

6-47

Chapter 6 Diag Operation


6.8 Board Diag (Board Test)

6.8.4 ASIC Test


Provides the ASIC built-in IJAC and JBIG tests.
Table 6-23 All Test
Display After Diag

Note

Normal

Error

CHECK OK

*** Test Check NG

***: Displays the name of the test ended in error.


(ASIC IJAC / ASIC JBIG)

6.8.5 Relay/Signal Test


Table 6-24 Relay/Signal Test
Item
Relay Test

Relay Toggle
Test
Relay Set Test

Hook Test

Hook Toggle
Test
Hook Set Test

Range

Description

0150 - 9999

Toggles the Relay signal within the specified


frequency.

ON, OFF

Outputs the Relay signal at a specified level.

0150 - 9999

Toggles the Hook signal within the specified


frequency.

ON, OFF

Outputs the Hook signal at a specified level.

Continuously sends the selected frequency


tone.

0Hz
400Hz
462Hz
1080Hz
1100Hz
1300Hz
Single Tone
Send

1500Hz
1650Hz
1850Hz
2100Hz
500Hz
600Hz
900Hz
1000Hz

DTMF Send

DTMF Continuous

0 - 9, A - D, *, #

Continuously sends the DTMF signal.

DTMF
Individually

16 digits
(each digit 0 - 9,
A - D, *, #)

Sends the multiple digits DTMF signal.

6-48

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.8 Board Diag (Board Test)
Table 6-24 Relay/Signal Test
Item

Range

DP10 Individually

10 digits
(each digit: 0 - 9)

DP20 Individually

10 digits
(each digit: 0 - 9)

Dial Pulse Send

Ring Back Tone

Description
Sends the multiple digits dial pulse (10pps)
signal.
Sends the multiple digits dial pulse (20pps)
signal.

Sends the ringback tone.

Sends the data specified with speed and pattern (no pattern for V.34).

5 patterns

Sends the data specified with speed and pattern.

5 patterns

Sends the data specified with speed and pattern.

5 patterns

Sends the data specified with speed and pattern.

5 patterns

Sends the data specified with speed and pattern.

V.34 33600bps
V.34 31200bps
V.34 28800bps
V.34 26400bps
V.34 24000bps
V.34 21600bps
V.34 19200bps
V.34 31200bps
V.34 16800bps
V.34 14400bps
V.34 12000bps
V.34 9600bps
Data Send

V.34 7200bps
V.34 4800bps
V.34 2400bps
V.29 9600bps
V.29 7200bps
V.29 4800bps
V.27ter 4800bps
V.27ter 2400bps
V.21 300bps
V.17 14400bps
V.17 12000bps
V.17 9600bps
V.17 7200bps

Line Voltage

Checks the Line Voltage status.

Line Current

Checks the Line Current status.

Gyrfalcon Service Manual Version 1.0

6-49

Chapter 6 Diag Operation


6.8 Board Diag (Board Test)
Procedure
The procedure below explains [DTMF Send] > [DTMF Continuous] as an example.
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Use the [ ] button to select [Fax/Scanner Diag], and press the [OK] button.

Press the [OK] button.

Fax/Scanner Diag
Board Test

Board Test
All test

Use the [ ] button to select [Relay/Signal Test], and press the [OK] button.

Board Test
Relay/Signal Test

Relay/Signal Test
Relay Test

Use the [ ] button to select [DTMF Send], and press the [OK] button.

Relay/Signal Test
DTMF Send

DTMF Send
DTMF Continuous

Press the [OK] button.

DTMF Continuous
DTMF:0

Use the [ ] or [ ] button to change the value and then press the [OK] button to start sending
the signal.

DTMF Continuous
DTMF:5
Now Sending Signal

DTMF Continuous
DTMF:5

To stop sending the signal, press the [<--] (Back) button.

DTMF Continuous
DTMF:5

6-50

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.8 Board Diag (Board Test)
9

Press the [<--] (Back) button to return to the [Fax Scanner Diag] screen.

Fax/Scanner Diag
Board Test

10

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

Gyrfalcon Service Manual Version 1.0

6-51

Chapter 6 Diag Operation


6.9 Information

6.9 Information
6.9.1 Scan Counter
Displays the scan counter value.
Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Use the [ ] button to select [Fax/Scanner Diag], and press the [OK] button.

Use the [ ] button to select [Information], and press the [OK] button.

Fax/Scanner Diag
Information

Information
Scan Counter

Press the [OK] button.

Scan Counter
FB: 0x00000001
DADF:0x00000002

Press the [<--] (Back) button to return to the [Fax Scanner Diag] screen.

Fax/Scanner Diag
Information

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

6-52

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.10 Scanner Maintenance

6.10 Scanner Maintenance


6.10.1 White Balance
Adjusts the White Balance.
Table 6-25 White Balance
Display After Diag

Item

Normal

Error

Auto Adjust(FB)

Adjust OK

Auto Adjust(FB) Adjust NG

Auto Adjust(DADF)

Adjust OK

Auto Adjust(DADF) Adjust NG

6.10.2 Shading Parameter


Specifies the Shading factor.
Table 6-26 Shading Parameter
Item

Range

Description

Coeff FB RED
Coeff FB GREEN
Coeff FB BLUE

4 digits (hexadecimal)
(each digit 0 - 9, A - F)

Coeff FB GRAY
Coeff DADF RED
Coeff DADF GREEN
Coeff DADF BLUE

4 digits (hexadecimal)
(each digit 0 - 9, A - F)

Coeff DADF GRAY


Target RED
Target GREEN
Target BLUE

2 digits (hexadecimal)
(each digit 0 - 9, A - F)

Target GRAY

Gyrfalcon Service Manual Version 1.0

6-53

Displays or changes the shading factor of each


item.

Chapter 6 Diag Operation


6.10 Scanner Maintenance

6.10.3 Registration Parameter


Specifies the parameter value of the registration.
Table 6-27 Registration Parameter
Item

Range

Description

Regi FB Lead
Regi FB Side
Regi DADF Lead (Front)
Regi DADF Side (Front)

3 digits (each digit 0 - 9)

Displays or changes the registration adjustment


values of each item.

Regi DADF Lead (Back)


Regi DADF Side (Back)
Regi DADF Lead (Front Dup)

6.10.4 Auto Registration


Specifies whether to set Auto Registration to ON or OFF.
Table 6-28 Auto Registration
Item

Range

Auto Registration

Description
Enables or disables the auto registration adjustment feature.

ON, OFF

6.10.5 Sensor Parameter


Specifies the setting value of the Sensor Parameter.
Table 6-29 Sensor Parameter
Item
Feed Sensor

Range

Description

3 digits (each digit 0 - 9)

6-54

Displays or changes the power control value of


the Feed Sensor.

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.10 Scanner Maintenance

6.10.6 Vertical Scan Mag.


Specifies the parameter value of the Vertical Scan magnification.
Table 6-30 Registration Parameter
Item

Range

Description

2 digits (hexadecimal)
(each digit 0 - 9, A - F)

Displays or changes the parameter value of each


item of the magnification for the slow scanning
direction.

Mag FB COLOR
Mag FB GRAY
Mag DADF COLOR
Mag DADF GRAY

6.10.7 Test Pattern


Specifies the test pattern and the parameter value of the test.
Table 6-31 Test Pattern
Item
Pattern No.

Range

Description

3 digits (each digit 0 - 9)

Displays or changes the parameter value of each


item of the test pattern.

6.10.8 IIT I/O Check


Checks the IIT I/O components operation.

Table 6-32 IIT I/O Check


Item

Sensor Status

Description

Home Pos Sensor


Tray Sensor
Feed Sensor
DADF Cover Sensor

ON or OFF

Displays the status of each Sensor as ON or OFF.

DADF Feed2 Sensor


FB Cover Sensor

Gyrfalcon Service Manual Version 1.0

6-55

Chapter 6 Diag Operation


6.10 Scanner Maintenance
Table 6-33 IIT I/O Check
Item
Lamp

Set ON
Set OFF

Display After Diag


Normal
Check OK

Forward
FB Motor

Now Driving

Check NG

The lamp is set to ON.


The lamp is set to OFF.
Turns the FB Motor to the forward direction.

Reverse

Turns the FB Motor to the reverse direction.

Forward

Turns the DADF Motor to the forward


direction.

DADF Motor

Now Driving

Check NG

Reverse
DADF
Solenoid

Description

Error

Set ON
Set OFF

Check OK

Turns the DADF Motor to the reverse


direction.
The DADF Solenoid is set to ON.
The DADF Solenoid is set to OFF.

6.10.9 Scan Counter Clear

Table 6-34 IIT I/O Check


Item

Sensor Status

Counter Clear (FB)

Clears the value of the FB scan counter.

Counter Clear (DADF)

Clears the value of the DADF scan counter.

6.10.10 Carriage Drive_100


Carriage Drive_100 is the IIT jig for the ORT which continuously operates the carriage 100 times a test. If the
lump error or the home position error is detected, the display shows the message [Abnormal End].
Table 6-35 Carriage Drive_100
Item
Carriage Drive_100

Display After Diag


Normal
Complete

6-56

Error
Abnormal End

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)

6.11 System Data Setting (Parameter)


You can specify the Fax and Scan system data settings.
Procedure
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Use the [ ] button to select [Fax/Scanner Diag], and press the [OK] button.

Use the [ ] button to select [Parameter], and press the [OK] button.
Parameter
Chain Link: 101-001
Value(Hex): B5

Fax/Scanner Diag
Parameter

Cursor
4

Change the Chain Link number, and press the [OK] button.
Use the [ ] and [ ] buttons to move the cursor to right and left.
Use the [ ] and [ ] buttons to increase or decrease the value where the cursor is placed.
Press the [OK] button, and the Chain Link number changed will appear.
Parameter
Chain Link: 101-007
Value(Hex): B5

Cursor
5

Change the setting value, and press the [OK] button.


* (asterisk) will appear when the value is set.

Parameter
Chain Link: 101-007
Value(Hex): *43
6

Press the [<--] (Back) button to return the [Fax Scanner Diag] screen.

Fax/Scanner Diag
Parameter

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

Gyrfalcon Service Manual Version 1.0

6-57

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)

Table 6-36 Parameter List


Range

Factory
Default

Note

Scanner Fast Scan Start


Pixel

0-255

128

0 - 255: 12.8 mm (in


increments of 0.1 mm)

SYS002 _DEF_SCN_START
_LINE

Scanner Slow Scan Start


Position

0-255

128

0 - 255: 12.8 mm (in


increments of 0.1 mm)

840

SYS003 _DEF_SCN_MAG_
C

Scanner Magnification
(Color)

0-255

128

0 - 255: 6.4 mm (in


increments of 0.05 %)

840

SYS101 _DEF_SCN_MAG_
G

Scanner Magnification
(Gray)

0-255

128

0 - 255: 6.4 mm (in


increments of 0.05 %)

840

004

SYS_DEF_SCN_CARRIGE_POS

Scanner Carriage Position

0-60

840

005

SYS_DEF_ADF_START_DOT

ADF Fast Scan Start Pixel

0-255

128

0 - 255: 12.8 mm (in


increments of 0.1 mm)

840

008

SYS_DEF_ADF_START_DOT2

ADF Fast Scan Start Pixel


(Side 2)

0-255

128

0 - 255: 12.8 mm (in


increments of 0.1 mm)

840

006

SYS_DEF_ADF_START_LINE

ADF Slow Scan Start Position

0-255

159

0 - 255: 12.8 mm (in


increments of 0.1 mm)

840

009

SYS_DEF_ADF_START_LINE2

ADF Slow Scan Start Position (Side 2)

0-255

153

0 - 255: 12.8 mm (in


increments of 0.1 mm)

840

007

SYS_DEF_ADF_MAG_C

ADF Magnification (Color)

0-255

144

0 - 255: 6.4 mm (in


increments of 0.05 %)

840

102

SYS_DEF_ADF_MAG_G

ADF Magnification (Gray)

0-255

144

0 - 255: 6.4 mm (in


increments of 0.05 %)

700

003

SYS_DEF_FBC2_CLR_R

FB C2 Paper ColorR Correction Factor

065535

36213

0 - 2^16-1

700

004

SYS_DEF_FBC2_CLR_G

FB C2 Paper ColorG Correction Factor

065535

37734

0 - 2^16-1

700

005

SYS_DEF_FBC2_CLR_B

FB C2 Paper ColorB Correction Factor

065535

36786

0 - 2^16-1

700

006

SYS_DEF_FBC2_MONO

FB C2 Paper Mono Correc0tion Factor


65535

37636

0 - 2^16-1

700

007

SYS_DEF_ADCF2_- ADF C2 Paper ColorR CorCLR_R


rection Factor

065535

36874

0 - 2^16-1

700

008

SYS_DEF_ADCF2_- ADF C2 Paper ColorG Cor0CLR_G


rection Factor
65535

37813

0 - 2^16-1

700

009

SYS_DEF_ADCF2_- ADF C2 Paper ColorB CorCLR_B


rection Factor

065535

37159

0 - 2^16-1

700

010

SYS_DEF_ADCF2_- ADF C2 Paper Mono CorMONO


rection Factor

065535

38557

0 - 2^16-1

Parameter

Chain

Link

840

SYS001 _DEF_SCN_START
_DOT

840

Name

6-58

0 - 60

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Range

Factory
Default

Auto Shading ColorR Correction Factor

0-255

240

0 - 255

SYS_DEF_ASTGT_CLR_G

Auto Shading ColorG Correction Factor

0-255

240

0 - 255

103

SYS_DEF_ASTGT_CLR_B

Auto Shading ColorB Correction Factor

0-255

240

0 - 255

700

104

SYS_DEF_ASTGT_MONO

Auto Shading Mono Correc0-255


tion Factor

240

0 - 255

700

Fax Store ADF Scan Size


SYS_DEF_FAX_AD- Reduce Length (Feed Sen105
FCUT
sor Output Correction
Value)

700

106

700

107

700

108

700

109

700

110

SYS_DEF_ADFC2_MONO_DW

Auto Shading Mono DADF

950

100

IIT_AFE_REG_VER
SION

Scanner AFE Register Version

Parameter

Chain

Link

700

101

SYS_DEF_ASTGT_CLR_R

700

102

700

SYS_DEF_IIT_AUTOREG
SYS_DEF_AD-

FC2_CLR_R_DW
SYS_DEF_AD-

FC2_CLR_G_DW
SYS_DEF_AD-

FC2_CLR_B_DW

Name

IIT Auto Register Adjustment On/Off


Auto Shading ColorR

DADF Correction Factor


(DW)
Auto Shading ColorG

DADF Correction Factor


(DW)
Auto Shading ColorB

DADF Correction Factor


(DW)
Correction Factor (DW)

Note

0-10

0 mm - 10 mm

0,1

0: Enable
1: Disable

065535

31402

065535

32085

065535

32358

065535

31948

0,1

0:M0-1
1:M0-1mod

950

101

IMAGE_PREPRM_THROUGH1

PreIPS Through Setting 1

0-255

192

bit0 0: AFE
bit1 1: Shading Correction
bit2 2: GAP Correction
bit3 3: Mirror Processing
bit4 4: Masking Processing
bit5 5: White Balance
Machine Difference
Correction
bit6 6: Lamp Initial Start
Up Attribute Correction
bit7 7: ADF Lamp Time
Variation Attribute Correction

950

102

IMAGE_PREPRM_THROUGH2

PreIPS Through Setting 2

0-255

bit0 0: SS400 -> 600


dpi Conversion (to FXI/F)

Gyrfalcon Service Manual Version 1.0

6-59

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Chain

950

Link

103

Parameter

Name

Range

IMAGE_PARAM_TH Image Quality Parameter


ROUGH1
Through Setting 1

IMAGE_PARAM_TH Image Quality Parameter


ROUGH2
Through Setting 2

950

104

950

IMAGE_PARAM_TH Image Quality Parameter


105
ROUGH3
Through Setting 3

950

IMAGE_PARAM_TH Image Quality Parameter


106
ROUGH4
Through Setting 4

6-60

0-255

0-255

0-255

Factory
Default

Note

bit0 0: ENL Conversion


bit1 1: RGB 3x9 Filter
bit2 2: Enlarge/Reduce
bit3 3: 3x9 Color Conversion
bit4 4: Background
Suppression
bit5 5: NSP
bit6 6: NSP (Saturation
Conversion Factor)
bit7 7: Color Adjustment (Linear Conversion)

Continued from "Image


Quality Parameter
Through Setting 1"
bit0 8: Color Adjustment (L* INLUT)
bit1 9: 4-Color DLUT
Color Conversion
bit2 10: 3-Color DLUT
Color Conversion
bit3 11: JPEG Compression
bit4 12: K 5x5 Filter
bit5 13: Resolution
Conversion
bit6 14: Delete Border
bit7 15: TRC

Continued from "Image


Quality Parameter
Through Setting 1, 2"
bit7 16 - 23: Reserve

Continued from "Image


Quality Parameter
Through Setting 1, 2, 3"
bit7 24 - 31: Reserve

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Chain

Link

Parameter

950

107 DIAG_IMG_PATH

950

108

950

Name

Range

Factory
Default

Note
0 = Normal Operation
1 = Raw Image Output
1
2 = Raw Image Output
2
3 = 1 Dot Grid Output
4 = Vertical Gradation
Output
5 = Horizontal Gradation Output
6 = Solid Color Output
7 = Lamp On Silent
Image Output
8 = Lamp Off Silent
Image Output
9 = Shading Memory
Silent Image Output
10 = FXIF Test
11 = Patch Pattern
12 = AFE: Maximum
Transient Status
13 = AFE: Lamp
14 = AFE: Fixed Data
Output

Select Test Pattern

0-255

DIAG_IMG03_GRID
_SIZE

Test Pattern 3 Parameter

01023

200

1 Dot Grid Size

109

DIAG_IMG04_GRADATION

Test Pattern 4 Parameter

1-255

10

Vertical Gradation Step

950

110

DIAG_IMG05_GRADATION

Test Pattern 5 Parameter

1-255

10

Horizontal Gradation
Step

950

111 DIAG_IMG06_R_LV

Test Pattern 6 Parameter R

0-255

128

Image Path R Level

950

112 DIAG_IMG06_G_LV

Test Pattern 6 Parameter G

0-255

128

Image Path G Level

950

113 DIAG_IMG06_B_LV

Test Pattern 6 Parameter B

0-255

128

Image Path B Level

950

114 DIAG_IMG07_STEP Test Pattern 7 Parameter

065535

Output Thinning Cycle


(x100line)

950

115 DIAG_IMG08_STEP Test Pattern 8 Parameter

065535

Output Thinning Cycle


(x100line)

950

116

DIAG_IMG09_TEMP

Test Pattern 9 Parameter

Reserve

950

117 DIAG_IMG11_R_LV

Test Pattern 11 Parameter

Image Path R Level

790

308 FAX_DEF_CL

Fax Default Color

0,1

0: Black & White


1: Color

0: Standard
1: Fine
2: Super Fine
3: Photo

790

304 FAX_DEF_RESO

Fax Default Resolution

Gyrfalcon Service Manual Version 1.0

6-61

0-3

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Range

Factory
Default

0-2

0: Text
1: Text & Photo
2: Photo

Fax Default Density

-3-+3

-3 (Lighter3) - +3
(Darker3)

FAX_DEF_DELAY_H

Fax Default Specified Time


- Hour

0-23

21

0 h - 23 h

307

FAX_DEF_DELAY_M

Fax Default Specified Time


- Minute

0-59

0 min - 59 min

701

006

SYS_SET_FAX_TRANS

SystemSetting Sent/Unsent
Report

0-2

0: Do Not Deliver
1: Deliver Upon Error
2: Always Deliver

701

007

SYS_SET_FAX_BROAD

SystemSetting Broadcast
Report

0-2

0: Do Not Deliver
1: Deliver Upon Error
2: Always Deliver

701

008

SYS_SET_FAX_PROTOCOL

SystemSetting Protocol
Monitor

0-2

0: Do Not Deliver
1: Deliver Upon Error
2: Always Deliver

790

305

FAX_SET_SD_HEAD

FaxSetting Sender Record

0,1

0: Do Not Record
1: Record

825

200

FAX_COVER_NOTE

FaxSetting Add Cover Note

0,1

0: Disable
1: Enable

701

FAX_SET_COUN001
TRY

FaxSetting Country Setting

cFax
Cntry
Unkn
own

821

205 FAX_SET_CL_FAX

FaxSetting Color Fax


Enable/Disable

821

FAX_SET_DUS403
CARD_SIZE

821

407

821

Parameter

Name

Chain

Link

790

302

FAX_DEF_ORIG_TYPE

Fax Default Original Type

790

301

FAX_DEF_DENSITY

790

306

790

Note

cFaxCntryUnite Unknown
dStates

0,1

0: Disable
1: Enable

FaxSetting Discard Size

0-2

0: New Page
1: Cut Without New
Page
2: Auto Reduce

FAX_SET_DUP_PRT

FaxSetting Receive Print 2 Sided Print

0,1

0: 1 Sided
1: 2 Sided

411

SYS_SET_FAX_ACT

SystemSetting Communication Management Report

0,1

0: No Auto Delivery
1: Always Deliver

825

002

FAX_SET_LINE_TYPE

FaxSetting Line Type

0,1

0: PSTN
1: PBX

825

003

FAX_SET_DIAL_TYPE

FaxSetting Dial Type

0-2

0: PB
1: DP (10PPS)
2: DP (20PPS)

6-62

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Chain

825

Link

Parameter

006 FAX_SET_DRPD

Name

FaxSetting DRPD Pattern


Setting

Range

Factory
Default

Note

0-7

0: Disable
1: Pattern1
2: Pattern2
3: Pattern3
4: Pattern4
5: Pattern5
6: Pattern6
7: Pattern7
0: For Tel Only
1: For Fax Only
2: Switch Tel/Fax
3: Switch Ans/Fax
4: DRPD Mode

825

014

FAX_SET_RCV_MODE

FaxSetting Switch Receive


Mode

0-4

825

017

FAX_SET_AT_TELFAX

FaxSetting AutoAnswerTel
/ Fax Call Time

0-255

0 - 255 sec

825

018

FAX_SET_AT_ANSFAX

FaxSetting AutoAnswerAns/Fax Call Time

0-255

0 - 255 sec

825

019 FAX_SET_AT_FAX

FaxSetting AutoAnswer
Fax Call Time

0-255

0 - 255 sec

825

031 FAX_SET_RESND

FaxSetting Resend Times

0-5

0 - 5 times

825

032 FAX_SET_REDIAL

FaxSetting Redial Times

0-13

0 - 13 times

825

034

FAX_SET_INT_REDIAL

FaxSetting Redial Interval

1-15

1 - 15 min

825

035

FAX_SET_INT_TIMER

FaxSetting Communication
Interval Timer

3-255

3 - 255 sec

825

054

FAX_SET_HOOK_THRESH

FaxSetting OnHook Detect


Threshold Value

825

060 FAX_SET_DM_PRE

FaxSetting DM Prevent
Feature

825

FAX083
_SET_RING_VOL

825

096

825

Lower
Normal
Higher
0,1

0: Do Not Prevent
1: Prevent

FaxSetting Incoming Sound


Volume

0-3

0: OFF
1: Min
2: Middle
3: Max

FaxSetting Remote
Receive

0,1

0: Disable
1: Enable

FAX097 _SET_RMT_RCV_T
ONE1

FaxSetting Remote
Receive Tone 1st Digit

0-9

825

FAX098 _SET_RMT_RCV_T
ONE2

FaxSetting Remote
Receive Tone 2nd Digit

0-9

825

102

FAX_SET_PREFIX_SET

FaxSetting Add Prefix Dial

0,1

825

103

FAX_SET_PREFIX_NUM

FaxSetting Prefix Dial Number

FAX_SET_RMT_RCV

Gyrfalcon Service Manual Version 1.0

6-63

0: Do Not Add
1: Add
UINT8*5

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Parameter

Chain

Link

825

FAX_SET_LINE_602
MONI

825

635

FAX_SET_CAPAB_ECM

Name

Range

Factory
Default

Note

FaxSetting Line Moniter


Sound Volume

0-3

0: OFF
1: Min
2: Middle
3: Max

FaxSetting ECM Setting

0,1

0: Disable
1: Enable

825

701

FAX_SET_UI_FAX_- On-Panel Fax CommunicaSPEED


tion Speed

0-4

0 :2400
1: 4800
2: 9600
3: 14400
4: 33600

701

10

FAX_SET_FOWD_SET

FaxSetting Fax Receive


Print Transfer

0,2

0: Do Not Transfer
2: Always Transfer

701

11

FAX_SET_FOWD_PRT

FaxSetting Print Setting


Upon Fax Receive Print
Transfer

0,1

0: Do Not Print
1: Print

701

12

FAX_SET_FWD_ERR_PRT

FaxSetting Print Upon Fwd.


Error Print

0,1

0: Do Not Print
1: Print

820

001

DIAG_DIALLING_TYPE

Dial Type

0-2

821

101

DIAG_SYS_MACHINE_MODE

Operation Mode

0,1

Specify [1] to output the


monitor sound from the
speaker upon fax communication.
0: Normal Mode
1: Maintenance Mode
Specify whether to
send all the scanned
pages of fax ([1]) or to
delete all the scanned
pages of fax ([0]) upon
error during Send
Store.
0: Delete All
1: Send Stored Document

821

201

DIAG_CONTINUE_ILLEGAL

Operation after Error such


as Send Store Insufficient
Memory, etc.

821

202

DIAG_THRESH_MEMRX

Stop Fax Receive, Disable


Fax Receive (when Color
Fax is disabled)

0-100

821

203

DIAG_THRESH_RXPRINT

Transit to Immediate
Receive

0-99

821

204

DIAG_THRESH_MEMTX

Stop Send Store, Disable


Send Store Start

0-100

821

206

DIAG_THRESH_COLOR_FAX_RX

FAX Receive Disable (when


Color Fax is enabled)

0-2

821

207

DIAG_THRESH_GC_START

Start Garbage Correction

0-99

6-64

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Parameter

Name

Range

Chain

Link

821

401

DIAG_PAGE_MARGIN

Page Split Margin (Reduction: OFF)

0-127

821

406

DIAG_COLOR_RX_PAGE_LIMIT

Maximum Value of 1 Page


Data Upon Color Receive

0-64

701

009

DIAG_SEL_OPP_NAME

Recipient Channel Second


Priority Notation Setting of
Communication Management Report

790

401

DIAG_G3M_RX_RESO

Resolution Setting Upon


Receive

0-128

821

412

DIAG_PAGE_MARGIN_REDUCTION

Page Split Margin (Reduction: ON)

0-127

825

001 DIAG_NCU_TYPE

825

004

DIAG_DP_RELAY_DELAY

Interval Until Relay Switch


(Interval Until Steady Line)
Upon Pulse Dial

0-255

825

005

DIAG_DRPD_ENABLE

Allow/Restrict DRPD Setting

0,1

825

013

DIAG_DIS_DP_20PPS

20PPS Pulse Dial

0,1

825

015

DIAG_CNG_DETECT_TIME

CNG Detect Time

0-255

0-255

NCU Type

0,1

0,1

825

016

DIAG_AUTO_ANSWER_TIME

External Phone Calling


Time (Time to output ringing sound from speaker
when unable to detect CNG
after starting to call)

825

025

DIAG_RING_CYCLE_MIN

(14/0.5) Ring Signal Cycle


Minimum Value

0-255

825

026

DIAG_RING_CYCLE_MAX

(100/0.5) Ring Signal Cycle


Maximum Value

8-255

825

027

DIAG_SELECT_DIALTONE

Dial Tone Frequency

0-3

825

028

DIAG_BUSYTONE_FREQ

Busy Tone Frequency

0-4

825

029

DIAG_BUSYTONE_PATTERN

Busy Tone Pattern

0-8

825

030

DIAG_BUSYTONE_DETECTION

Allow/Restrict Busy Tone


Detection Upon Calling

0,1

825

DIAG_NUM033 BER_OF_REDIAL_MAX

Maximum Redial Times

0-255

825

036

DIAG_CAPAB_NUM_CHECK

Check Same Recipient


Upon Recalling

0,1

Gyrfalcon Service Manual Version 1.0

6-65

Factory
Default

Note

0: Name of Recipient
Channel (to be displayed when an individual protocol is used.)
1: Phone Number
0x00: Normal
0x80: R8x3.85

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Chain

Link

Parameter

Name

825

037

DIAG_NUM_CHECK_TIMER

Interval Until Resending to


Same Recipient

1-255

825

045

DIAG_DAA_REG73
0

RingThreshold

0-255

825

046

DIAG_DAA_REG73
1

Complex

0-2

825

047

DIAG_DAA_REG73
3

DCCurve

0-4

825

048

DIAG_DAA_REG73
4

Rmake

825

049

DIAG_DAA_REG74
F

FastEdgePulseDial

825

050 DIAG_DAA_MODE

825

062

825

Range

Factory
Default

Note

0-255
0,1

SiDAA Operation Mode

0-255

DIAG_NUM_DIAL_PULSE

Number of Dial Pulses

0-2

063

DIAG_PB_TONE_TIME

PB Transmission Time

0-255

825

064

DIAG_PB_INTERDIGIT

PB Pause Time

0-255

825

065

DIAG_PB_ATT_LEVEL

DTMF Transmission Attenuator Level

4-15

825

066

DIAG_PB_LEVEL_SUB

Difference of DTMF HighPass/Low-Pass Level

0-15

825

067

DIAG_MAKE_10PPS

10PPS Make Time

1-106

825

068

DIAG_BREAK_10P
PS

10PPS Break Time

1-106

825

069

DIAG_MAKE_20PPS

20PPS Make Time

1-106

825

070

DIAG_BREAK_20P
PS

20PPS Break Time

1-106

825

071

DIAG_DP_INTERDIGIT

DP Interdigit Pause Time

0-255

825

072 DIAG_PAUSE_TIME (4/0.1) Pause Time

0-255

825

073 DIAG_BLIND_TIME

Blind Dial Time

0-255

825

DIAG_TIME_TO_074 DETECT_DIALTONE

Interval Until Dial Tone


Detection Timeout

0-255

825

079

DIAG_ONHOOK_DETECT_TIME

ONHOOK Detect Time

10255

825

080

DIAG_OFFHOOK_DETECT_TIME

OFFHOOK Detect Time


Upon No Online RING Signal

15255

6-66

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Parameter

Name

Range

Factory
Default

Note

Chain

Link

825

DIAG_OFFHOOK_081 DETECT_TIME_RING

OFFHOOK Detect Time


Upon Online RING Signal

825

DIAG_EX_RING084 ER_FREQ_ON_TIME

External Phone Calling Fre- 6250quency: ON


65535

6250 - 65535:3125 s 31250 s

825

DIAG_EX_RING085 ER_FREQ_OFF_TIME

External Phone Calling Fre- 6250quency: OFF


65535

6250 - 65535:3125 s 31250 s

825

086

DIAG_EX_RINGER_ON_T1

External Phone Calling ON


Time T1

5-250

825

087

DIAG_EX_RINGER_OFF_T2

External Phone Calling


OFF Time T2

5-250

825

088

DIAG_EX_RINGER_ON_T3

External Phone Calling ON


Time T3

5-250

825

089

DIAG_EX_RINGER_OFF_T4

External Phone Calling


OFF Time T4

5-250

825

090

DIAG_DIS_DIALTONE_PSTN

Detect Dial Tone on Public


Line

0,1

825

DIAG_MANU092 AL_CED_START_TIME

CED Signal Transmission


Start Time Upon Manual
Send

0-255

825

093

CNG Signal Transmission


Start Time

0-255

825

DIAG_MANU094 AL_CNG_START_TIME

CNG Transmission Start


Time Upon Manual Send

0-255

825

099

DIAG_RING_ON_JUDGE

Ring ON Judge Time

0-255

825

100

DIAG_RING_OFF_JUDGE

Ring OFF Judge Time

0-255

825

101

DIAG_RING_OFFMAX

Time to Judge Ring Disappeared from Line

0-255

825

103

DIAG_PREFIX_NUM_1

Prefix Dial Number1

0-255

825

104

DIAG_PREFIX_NUM_2

PrefixDial Number2

0-255

825

105

DIAG_PREFIX_NUM_3

PrefixDial Number3

0-255

825

106

DIAG_PREFIX_NUM_4

PrefixDial Number4

0-255

825

107

DIAG_PREFIX_NUM_5

PrefixDial Number5

0-255

825

108

DIAG_SIDAA_MANUAL_CALIBRATION

SiDAA Manual Calibration

DIAG_CNG_SEND_
START_TIME

Gyrfalcon Service Manual Version 1.0

6-67

15255

0,1

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Parameter

Name

Range

Chain

Link

825

110

825

DIAG_DIAL111 TONE_ONOFFPTN_MIN

Minimum Time of Dial Tone


ON/OFF

0-255

825

DIAG_DIAL112 TONE_ONOFFPTN_MAX

Maximum Time of Dial


Tone ON/OFF

8-255

825

201

DIAG_NCU_COUNTRY_RELAY

NCU Country Setting Relay Setting

0,1

825

202

DIAG_DAA_REG73
2

FastEdgePulseDial2

0,2

825

203

DIAG_DAA_REG_E
MI

DAA SSD Register 0x02


Setting

825

601

DIAG_LINE_MONITOR_ENABLE

Line Monitor Setting

0,1

825

604

DIAG_CED_DETECT_TIMER

CED Detect Time

25255

825

666

DIAG_MANUAL_CNG_SIGNAL

Manual Send CNG Transmission

0,1

825

605

DIAG_CNG_STOP_
SELECT

CNG Transmission Stop


Judge Selection

0,2

825

608

DIAG_RTN_TX_RATE

RTN Command Transmission Standard (Rate)

0-100

825

609

DIAG_RTN_TX_LINE

RTN Command Transmission Standard (Serial Line


Number)

0-255

825

610

DIAG_G3M_CALL_T1_TIMER

T1 Timer Value Soon After


Calling

0-255

825

611

DIAG_G3M_TX_T1_TIMER

T1 Timer Value Upon


Sending

0-255

825

612

DIAG_G3M_RX_T1_TIMER

T1 Timer Value Upon


Receiving

0-255

825

613

DIAG_G3M_T2_TIMER

T2 Timer Value

0-255

825

614

DIAG_G3M_T3_TIMER

T3 Timer Value

0-255

825

615

DIAG_G3M_AUTO_T4_TIMER

Auto Send/Receive T4
Timer Value

0-255

825

616

DIAG_G3M_MAN_T
4_TIMER

Manual Send/Receive T4
Timer Value

0-255

825

617

DIAG_G3M_IVL_TIMER

Silent Time Timer Value

0-255

DIAG_DIS_DIALTONE_PATTERN

Detect Dial Tone Pattern

6-68

Factory
Default

Note

0,1

0-255

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Parameter

Name

Range

Chain

Link

825

618

DIAG_G3M_FSK_CHK_TIMER

FSK Observation Timer


Value

0-255

825

619

DIAG_ITUT_PIX_DELAY

Image Information Send


Delay Time

0-255

825

620

Image Information Receive


DIAG_G3M_Dropout Observation Timer
DROP_OUT_TIMER
Value

825

621

DIAG_G3M_NSF_DIS_TIME

NSF/DIS Transmission
Time

0-3

825

622

DIAG_G3M_TX_MODEM_SPEED

Communication Mode
Upon Sending (Speed)

0-5

825

623

DIAG_G3M_RX_MODEM_SPEED

Communication Mode
Upon Receiving (Speed)

0-5

825

625

DIAG_G3M_DIS_IG
NORE_NO

DIS Ignore Times

825

626

DIAG_G3M_TSI_CI
G_MODE

TSI/CIG Send Timing

0-2

825

627

DIAG_G3M_WITH_
CSI

CSI Send

0,1

825

628

DIAG_G3M_FTT_FALLBACK

Number of FTT Until Fallback

0-2

825

629

DIAG_G3M_TCF_CHECK

TCF Signal Judge Standard

0,1

825

630

DIAG_G3M_TX_CASend Cable Equalizer


BLE_EQU

0-3

825

631

DIAG_G3M_RX_CABLE_EQU

Receive Cable Equalizer

0-4

825

632

DIAG_G3M_TAP_H
OLD

TAP HOLD

0,1

825

633

DIAG_G3M_V29_E
PT

EP Tone

0,1

825

634

DIAG_EXTENDED_DIS_DTC

DIS/DTC FIF Transmission


Bytes

0-10

825

636

DIAG_G3M_CTC_N
O

ECM/CTC Transmission
Times

0-7

825

637

DIAG_G3M_T5_TIMER

RNR Signal Timer

0-255

825

638

DIAG_G3M_EQM_4
8

4800bps EQM Comparison


Value

0-127

825

639

DIAG_G3M_EQM_7
2

7200bps EQM Comparison


Value

0-127

825

640

DIAG_G3M_EQM_9
6

9600bps EQM Comparison


Value

0-127

Gyrfalcon Service Manual Version 1.0

6-69

0-255

0-255

Factory
Default

Note

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Chain

Link

Parameter

Name

825

641

DIAG_G3M_EQM_1
20

12000bps EQM Comparison Value

0-127

825

642

DIAG_G3M_EQM_1
44

14400bps EQM Comparison Value

0-127

825

643

DIAG_G3M_EQM_T TCM7200bps EQM ComCM72


parison Value

0-127

825

644

DIAG_G3M_EQM_T TCM9600bps EQM ComCM96


parison Value

0-127

825

DIAG_G3M_V34_645 MAX_SYMBOL_RATE

825

646

825

DIAG_G3M_V34_S
647 YM_RATE_ENABLE1

825

648

825

Range

Symbol Speed Maximum


Allowed Value (Enable
Upon Receiving)

0-5

Bit Speed Maximum Value

1-14

Symbol Speed Enable


Command

0-61

DIAG_G3M_V34_BI
T_RATE_ENABLE1

Bit Speed Enable Command 1

0-255

649

DIAG_G3M_V34_BI
T_RATE_ENABLE2

Bit Speed Enable Command 2

0-63

825

650

DIAG_G3M_V34_CTRL_BIT_RATE

Control Channel Bit Speed

825

DIAG_G3M_V34_BI
653 T_RATE_THRESHOLD

825

655

825

DIAG_G3M_V34_MAX_BIT_RATE

Note

0,1

Bit Speed Selection


Threshold Value

0-255

DIAG_G3M_V8_TE
_TIME

V8Te Time

0-255

656

DIAG_G3M_V34_CC_TIMER

Interval From V34 Mode


(Phase2) Until Control
Channel

5-255

825

657

DIAG_G3M_V34_SHIFT_G3

Setting Whether to Transit


to G3 Mode Upon V34_CC_TIMER Timeout

0,1

825

658 DIAG_CAPAB_V34

V34 Capability

0,1

825

659

DIAG_ANSAM_SEND_TIME

ANSam Signal Maximum


Transmission Time

825

660

DIAG_ANSAM_START_TIME

Interval From Line Close


Until ANSam Signal Transmission

22255

825

661

DIAG_G3M_TX_CODING

Upon Sending Coding


Method

0-3

825

662

DIAG_G3M_RX_CODING

Upon Receiving Coding


Method

0-3

825

664

DIAG_RX_GAIN_ADJUSTMENT

Receive Gain Correction


Value

0-255

6-70

Factory
Default

1-255

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Parameter

Name

Range

Chain

Link

825

665

DIAG_G3M_V34_FRAME_SIZE

V34 1 Frame Size

825

667

DIAG_TONE_TX_ATT

Tone Transmission Level

0-15

825

668 DIAG_RX_ATT

Incoming Level

0-3

825

669

DIAG_SAVE_ERROR_RX_DATA

Store Decode Error Page

0,1

825

673

DIAG_DFAULT_JBIG_LRLTWO

LRLTWO (Reference Line)


Value

0,1

825

DIAG_EX702 TEL_HOOK_THRESH_0

Threshold Value 0 for


External Phone HOOK
Detection

0-255

825

DIAG_EX703 TEL_HOOK_THRESH_1

Threshold Value 1 for


External Phone HOOK
Detection

0-255

825

DIAG_EX704 TEL_HOOK_THRESH_2

Threshold Value 2 for


External Phone HOOK
Detection

0-255

825

DIAG_CAPAB_EX705 TEL_HOOK_SUPPLEMENT

Support ETSI Standard


(Enable/Disable Start)

0,1

825

DIAG_EXSupport ETSI Standard


TEL_HOOK_SUP(Voltage to Decide Exter706
PLEMNT_VOLTHRE
nal Phone OFFHOOK)
SH

10-20

950

DIAG_FOR001 GET_ERROR_SECRET

0-255

950

002

950

DIAG_PMQA003 T_BOARD_SECRET

950

004

DIAG_DONT_DEL_
TXFILE

0,1

950

005

DIAG_DONT_PR_R
CVFILE

0,1

950

006

DIAG_MON_SPEED_38400

0,1

950

007

DIAG_COMM_TIME_MEASURE

0,1

950

008

DIAG_WITHOUT_ICM

0,1

950

009

DIAG_COMM_PARAM

0,1

DIAG_CODE_CHECK_SECRET

Gyrfalcon Service Manual Version 1.0

Note

0,1

0-255
0-255

6-71

Factory
Default

0: Disable
1: Enable

10, 15, 20 (V)

Chapter 6 Diag Operation


6.11 System Data Setting (Parameter)
Table 6-36 Parameter List
Parameter

Name

Range

Factory
Default

Note

Chain

Link

950

010 DIAG_EQM_READ

0,1

950

011

DIAG_AGCVAL_READ

0,1

950

DIAG_FAX012 COM_DEBUG_INFO

950

013

DIAG_G3M_V8_SHIFT_G3

0,1

950

014

DIAG_SERIMON_RX_ENABLE

0,1

950

015

DIAG_CODEC_DEBUG_DISP

0,1

950

016

DIAG_WARMBOOT_DISABLE

0,1

950

017

DIAG_FORCED_POLLING

0,1

950

018

DIAG_REMOTE_DIAG

0,1

950

019 DIAG_ECM_RX_64

Frame Size Setting Upon


ECM Sending

0,1

950

020 DIAG_ECM_TX_64

Frame Size Setting Upon


ECM Receiving

0,1

950

021 DIAG_SELECT_LN

Select Maximum Record


Paper Length

0-2

950

022

DIAG_CAPAB_FULLCOLOR

950

118

DIAG_FREQ_DETECT_LEVEL

825

DIAG_AN708 SWER_DELAY_MINIMUM

Minimum Call Time in Auto


Receive Mode (FAX only,
TEL/FAX, ANS/FAX)

0-255

0: Disable
1 - 255 sec

825

DIAG_AN709 SWER_DELAY_MAXIMUM

Maximum Call Time in Auto


Receive Mode (FAX only,
DRPD)

0-255

0: Disable
1 - 255 sec

825

710 DIAG_DIS_DP

Restrict Dial Pulse

825

DIAG_FAX707 LINE_TEST_VOLTAGETHRESH

Voltage Threshold Value


for Line Voltage Detection

0,1

0,1
Frequency Detect Level
(For Filter)

6-72

0-3

0: Allow DP
1: Restrict DP

0,1
10-50

10 - 50

1Step/1V

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.12 Backup (BackUP Data)

6.12 Backup (BackUP Data)


Backup data in SRAM and EEPROM can be cleared.

Item

Description

All Clear
User Clear
System Clear

Refer to Table 6-37.

User&System Clear
System Data Init
Document Clear

Table 6-37 Initialization Data


User

System

User&
System

EEPROM System Data

SRAM System Data

System Error History

SW Bug History

Diag History

Local ID G3

Local Name

TX Header Logo

Forward Dial Number

System Counter

Speed Dial Block (Speed Dial Control Block)

Dial Group Block (Group Dial Registration Block)

SCAN to FTP/SMB Address Book

SCAN to Email Address Book

Email Group Block (E-mail Group Registration


Block)

Email Subject

Email Text

Block for Communication Result Registration

Communication Result Registration for Protocol


Monitor Report

Backup Check Data1

Calling Table

Broadcast CRB Document Number

Gyrfalcon Service Manual Version 1.0

6-73

Document

System
Data

All

Data

Chapter 6 Diag Operation


6.12 Backup (BackUP Data)
Table 6-37 Initialization Data
Data

All

User

System

User&
System

Document

Management Data in Broadcast 1 Job

Broadcast 1 Job Result

Substitute Queue

Receiving Document Information

Document Number

Document Management Table

Directory Management Table

FAT Chain Table

FAT Chain Save Range

FAT Delete Status Table

Table of Number of Sector Erase Times

Garbage Correction Information

Sector for Garbage Correction

Garbage Correction Preparation Sector

Fax Communication Speed Counter

ADF Scan Counter

Platen Scan Counter

Total Signal Number

Signal Data Buffer Pointer

Signal Information Table

Signal Data Buffer

Number of SCJL Job Log Registrations

SCJL Job Log Data

Backup Check Data 2

Backup Data Status

Backup RAM Bottom

System
Data

Procedure
The following procedure explains how to clear the data using [User Clear] as an example.
1

Enter the CE mode. (See "6.1.2 How To Enter the CE Mode".)

Use the [ ] button to select [Fax/Scanner Diag], and press the [OK] button.

6-74

Gyrfalcon Service Manual Version 1.0

Chapter 6 Diag Operation


6.12 Backup (BackUP Data)
3

Use the [ ] button to select [BackUp Data], and press the [OK] button.

Fax/Scanner Diag
BackUp Data

BackUp Data
All Clear

Use the [ ] button to select [User Clear], and press the [OK] button.

BackUp Data
User Clear

User Clear
Ready

Press the [OK] button.

User Clear
Processing

User Clear
Complete

Press the [<--] (Back) button to return to the [BackUp Data] screen.

BackUp Data
User Clear

Press the [<--] (Back) button to return to the [Fax Scanner Diag] screen.

Fax/Scanner Diag
BackUp Data

Exit the CE mode. (See "6.1.4 How to Exit the CE Mode".)

Gyrfalcon Service Manual Version 1.0

6-75

Chapter 6 Diag Operation


6.12 Backup (BackUP Data)

6-76

Gyrfalcon Service Manual Version 1.0