You are on page 1of 4

Setup of SM 100 for React Solution

1. Insert network cable


2. To get to the Operations mode, press:
3. Setup the last portion of the IP-Address
3.1. While holding down the
key press 141 for the menu mode
If successful the scale screen will display a string of information starting with
SP0:
3.2. Press 135 and then the
key
The scale screen should display a string starting with SP135: Port Number
3.3. Enter the three digits required for the last portion of IP address.
3.4. Press

to save the IP.

3.5. Press 49 and then the


key
The scale screen should display a string starting with SP49: Network Interface
3.6. Press 2 and it should change to Twisted Cable
3.7. Press

to save the setting

3.8. Press the


key and the scale will pause for a few seconds and restart
automatically
3.9. To Exit out of the Operation mode, press:
4. Change the first three portions of the IP-Address and the scales subnet mask

4.1. Press the following keys in sequence


to enter Z-Mode
The scale screen should display a string To Clear daily transactions
4.2. To display / change the first three digits of the IP-Address
4.3. Hold down the
key and type in 0416
The scale screen should a string: Scale IP Address
4.4. If required correct the IP-Address and press
to save
This should return to the screen with the string To clear daily trans

4.5. Hold down the


key and type in 0418
The scale screen should display the string Subnet Mask
4.6. If required correct the subnet mask and press
to save
This should return to the screen with the string To clear daily trans
4.7. Press
twice to exit Z-Mode.
4.8. Power off the scale with the power switch located at the bottom of the
scale
4.9.
4.10.

While the scale is off press and hold


and
.
While holding the above keys power on the scale
The scale display should have the following text Initialize network?

4.11.

Press the

key to initialize the scale network.

5. Label Setup

5.1. Press
5.2. Press 12 then
5.3. Press 1 then
5.4. Set the With and press
5.5. Set the height and press

5.6. While holding down the


key press 141 for the menu mode
If successful the scale screen will display a string of information starting with
SP0:
5.7. Press 24 and then the
key
Screen display should start with SP24:
5.8. Type in 16 and press
Screen display should start with SP25:

5.9. Type in 16 and press


Screen display should start with SP26:
5.10.
Press the
automatically

key and the scale will pause for a moment and reset

5.11.
Press
to enter S-Mode
Screen display should start with PLU Programming
5.12.
Press 12 and
Screen display should start with Program free format
5.13.
Press 1 and then
Screen display should start with Copy existing format?
5.14.
Press
to confirm
Screen display should start with Free Format #
5.15.
Type in 16 and press
Screen display should start with Enter label width
5.16.
5.17.

Press
to save
Screen display should start with Program free format

5.18.
5.19.

Press
to return to normal startup screen.
Turn the scale off and then back on.

6. To set the scale to Weight-Mode or Non-Weight mode

6.1. While holding down the


key press 141 for the menu mode
If successful the scale screen will display a string of information starting with
SP0:
6.2. Press 41 and then the
key
The scale screen should display a string starting with SP41 :
6.3. Press 0 to set the scale to non-weighted item and 1 to set the scale to weighted
item
6.4. Press

to save the selected choice

7. Program a PLU to a predefined key

7.1. Press

to enter S-Mode

7.2. Press 4 and then


7.3. Press the PLU number and then the key you wish to assign it to.
E.g.: 1005 and then the key you wish to assign it to, in this case MG Daily key.
7.4. Repeat step 7.3 until you are done and then press
normal operation

to return to

8. Setup the scale with React System


Edit the windows host file.
8.1. Add all scale IP addresses with their corresponding names
8.2. E.G: 192.168.0.99 S0097
9. Copy the TSA-GEN folder to the drive
10. Edit the SCALES.TSI file.
10.1.
Include all the scales that were added to the Windows host file.
10.2.
E.G: The following is an entry in the Scales.TSI file.
10.3.
S0097 WTDP=3
10.4.
Where S0097 is the scale as it is defined in the Windows hostfile.
11. Edit the DEPTS.TSI file
11.1.
Ensure that all scales added to the host file are included in this file.
11.2.
E.G: Such as the following entry: S0097=ALL
12. The batch file that the react system uses is as follows:
12.1.
Copy 4CUSTA.PRN 4CUSTABAK.TXT
12.2.
SET BARFLAG=20
12.3.
TSA-GEN PLU 4CUSTA SETDEPTS
12.4.
Copy 4CUSTABAK.TXT 4CUSTA.PRN
13. Setup the variables in the scale maintenance screen
14. Press save
14.1.
Select the send all changes option and then press send updates to scales.
Contact Persons:
Mogapi: 082 884 3021
Viju: 082 884 3067