Steel Grades
Anker Schroeder offer 4 standard steel grades for tie bars:
ASDO355
Diameter
fy
N/mm2
fua
N/mm2
ASDO355
M64 - M160
350
510
ASDO460
M64 - M165
460
610
ASDO500 ASDO500
M64 - M165
500
660
M64 - M170
700
900
ASDO460
ASDO700
ASDO700
The choice of steel grade depends on a number of factors, whilst the higher strength steel will always
produce the lightest weight anchor this may not be suitable for stiffness requirements, onsite welding or
lead-times. Other grades of steel are available please contact Anker Schroeder to discuss further.
Depending on diameter and length required Anker Schroeder tie bars are manufactured using selected
fine grained steel, high strength low alloy steel or quench and tempered steel. The choice of steel is
dependent upon your specific project requirements but the above minimum properties will be met. All tie
bars and components are manufactured to a quality system audited and accredited to ISO 9001.
FED
FED
intertidal zone
MLW
fill material
permanent immersion
zone
buried zone
(water side)
When designing anchors for retaining walls the following should be considered
Design Resistance the anchorage
should be designed to provide sufficient design resistance to satisfy the
design load required (note the design
resistance is calculated differently
between design codes).
of the shaft diameter and subsequently a higher grade tie bar (e.g. ASDO700)
may not be the most suitable. Movement under imposed loads may be
reduced in many cases by pre-loading
the anchors at the time of installation
to develop the passive resistance of
the ground. Pre-loading of the anchor
is most easily achieved at a threaded
end of the anchor by means of a hydraulic jack, consideration to the practicality of this should be made at design
stage.
Design
Considerations
Settlement the effect of sag of the
anchor and forced deflection due to
settlement of fill may induce significant
bending stresses at a fixed anchorage
and increase the tensile stress in the
tie rod locally. Shear stresses may also
be induced into the thread if a tie rod is
displaced when the fill settles causing
compound stresses which must be allowed for in the detailed design. This
can often be overcome by provision of
articulated joints at connections to the
wall.
Whether a connection is articulated or
fixed will affect the design resistance of
the tie bar. If connections are fixed then
a greater thread size must be used to
accommodate any bending introduced
to the anchor.
Forged eye
anchor wall
wall centres
link plates
main wall
waling
articulation
spherical nut
articulation
articulation
bearing plate
A g
fy
fua
k t
= a reduction factor allowing for combined bending and tension in the thread
(typically 0.6 where bending at the connection must be considered and 0.9
M0 & M2
cross
sectional
area of shaft
cross
sectional
area of thread
d= variable
Ag
As
As
Ag
standard rolled thread A s = A g
fixed ration A s/A g
d= pitch
Design
Considerations
Upset forging
Unlike traditional forging in which a
parent metal is heated and forged into a
smaller dimension upset forging is a
process by which parent metal is increased in sectional area. In the case of
anchors this allows the ends of a bar to
be increased in section and threads cut
or rolled onto the forged cylinder. The
same process can also be used to form
articulated ends such as eyes or spherical ends.
160
anchor bar
with standard
rolled threads
140
120
anchor bar
with upset
forged threads
100
80
60
40
20
0
1,000
2,000
3,000
4,000
5,000
6,000
7,000
Dt
As
All grades
Metric
mm2
mm
64
2,676
48-56
68
3,055
52-60
72
3,460
52-64
76
3,889
56-68
80
4,344
60-72
85
4,948
63-76
90
5,591
68-80
95
6,273
70-85
100
6,995
75-90
kt = 0.6
Dg
Ag
Fy
Fua
Ft,Rd
ASDO355 mm
mm2
kN
kN
kN
M64/48
48
1,810
642
923
642
M68/52
52
2,124
754
1,083
748
M72/56
56
2,463
874
1,256
847
M76/60
60
2,827
1,004
1,442
952
M80/63
63
3,117
1,107
1,590
1,063
M85/68
68
3,632
1,289
1,852
1,211
M90/70
70
3,848
1,366
1,963
1,366
M95/75
75
4,418
1,568
2,253
1,536
M100/80
80
5,027
1,784
2,564
1,712
Anchor code
Optimum shaft diameter
Shaft gross area
Shaft yield capacity
Shaft ultimate capacity
Tensile resistance
Dg
Ag
Fy
Fua
Ft,Rd
ASDO355 mm
mm2
kN
kN
kN
M64/56
56
2,463
874
1,256
874
M68/60
60
2,827
1,004
1,442
1,004
M72/64
64
3,217
1,142
1,641
1,142
M76/68
68
3,632
1,289
1,852
1,289
M80/72
72
4,072
1,445
2,076
1,445
M85/75
75
4,418
1,568
2,253
1,568
M90/80
80
5,027
1,784
2,564
1,784
M95/85
85
5,675
2,014
2,894
2,014
M100/90
90
6,362
2,258
3,244
2,258
ASDO355
Anchor code
Optimum shaft diameter
Shaft gross area
Shaft yield capacity
Shaft ultimate capacity
Tensile resistance
kt = 0.9
kt = 0.6
Dg
Ag
Fy
Fua
Ft,Rd
ASDO460 mm
mm2
kN
kN
kN
M64/48
48
1,810
832
1,104
784
M68/52
52
2,124
977
1,295
895
M72/52
52
2,124
977
1,295
977
M76/56
56
2,463
1,133
1,502
1,133
M80/60
60
2,827
1,301
1,725
1,272
M85/63
63
3,117
1,434
1,902
1,434
M90/68
68
3,632
1,671
2,215
1,637
M95/72
72
4,072
1,873
2,484
1,837
M100/75
75
4,418
2,032
2,695
2,032
Anchor code
Optimum shaft diameter
Shaft gross area
Shaft yield capacity
Shaft ultimate capacity
Tensile resistance
Dg
Ag
Fy
Fua
Ft,Rd
ASDO460 mm
mm2
kN
kN
kN
M64/56
56
2,463
1,133
1,502
1,133
M68/60
60
2,827
1,301
1,725
1,301
M72/64
64
3,217
1,480
1,962
1,480
M76/68
68
3,632
1,671
2,215
1,671
M80/72
72
4,072
1,873
2,484
1,873
M85/76
76
4,536
2,087
2,767
2,087
M90/80
80
5,027
2,312
3,066
2,312
M95/85
85
5,675
2,610
3,461
2,610
M100/90
90
6,362
2,926
3,881
2,926
ASDO460
Anchor code
Optimum shaft diameter
Shaft gross area
Shaft yield capacity
Shaft ultimate capacity
Tensile resistance
kt = 0.9
kt = 0.6
Dg
Ag
Fy
Fua
Ft,Rd
ASDO500 mm
mm2
kN
kN
kN
M64/48
48
1,810
905
1,194
848
M68/52
52
2,124
1,062
1,402
968
M72/52
52
2,124
1,062
1,402
1,062
M76/56
56
2,463
1,232
1,626
1,232
M80/60
60
2,827
1,414
1,866
1,376
M85/63
63
3,117
1,559
2,057
1,559
M90/68
68
3,632
1,816
2,397
1,771
M95/70
70
3,848
1,924
2,540
1,924
M100/75
75
4,418
2,209
2,916
2,209
Anchor code
Optimum shaft diameter
Shaft gross area
Shaft yield capacity
Shaft ultimate capacity
Tensile resistance
Dg
Ag
Fy
Fua
Ft,Rd
ASDO500 mm
mm2
kN
kN
kN
M64/56
56
2,463
1,232
1,626
1,232
M68/60
60
2,827
1,414
1,866
1,414
M72/64
64
3,217
1,608
2,123
1,608
M76/68
68
3,632
1,816
2,397
1,816
M80/72
72
4,072
2,036
2,687
2,036
M85/75
75
4,418
2,209
2,916
2,209
M90/80
80
5,027
2,513
3,318
2,513
M95/85
85
5,675
2,837
3,745
2,837
M100/90
90
6,362
3,181
4,199
3,181
ASDO700 mm
mm2
kN
kN
kN
M64/48
48
1,810
1,267
1,629
1,156
M68/52
52
2,124
1,487
1,911
1,320
M72/52
52
2,124
1,487
1,911
1,487
M76/56
56
2,463
1,724
2,217
1,680
M80/60
60
2,827
1,979
2,545
1,877
M85/63
63
3,117
2,182
2,806
2,137
M90/68
68
3,632
2,542
3,269
2,415
M95/70
70
3,848
2,694
3,464
2,694
M100/75
75
4,418
3,093
3,976
3,022
ASDO500
Anchor code
Optimum shaft diameter
Shaft gross area
Shaft yield capacity
Shaft ultimate capacity
Tensile resistance
kt = 0.9
ASDO700
kt = 0.6
Dg
Ag
Fy
Fua
Ft,Rd
kt = 0.9
Anchor code
ASDO700 M64/56
M68/60
M72/64
M76/68
M80/72
M85/76
M90/80
M95/85
M100/90
Optimum shaft diameter
Dg
mm
56
60
64
68
72
76
80
85
90
Shaft gross area
Ag
mm2
2,463
2,827
3,217
3,632
4,072
4,536
5,027
5,675
6,362
Shaft yield capacity
Fy
kN
1,724
1,979
2,252
2,542
2,850
3,176
3,519
3,972
4,453
Shaft ultimate capacity
Fua
kN
2,217
2,545
2,895
3,269
3,664
4,083
4,524
5,107
5,726
Tensile resistance
Ft,Rd
kN
1,724
1,979
2,242
2,520
2,815
3,176
3,519
3,972
4,453
*Note: The above sizes are standardised, other shaft and thread ratios can be adapted to suit your project requirements, e.g. for sacrificial steel requirements or smaller design loads,
design resistance calculated as per EN1993-5 with M0 = 1.0 & M2 = 1.25 and kt as noted.
8
Dt
Dg
Product
Data
upset thread
105
7,755
80-95
110
8,556
85-100
115
9,395
85-105
120
10,274
95-110
125
11,191
95-115
130
12,149
100-120
135
13,145
105-125
140
14,181
105-130
145
15,256
110-135
150
16,370
115-140
155
17,524
120-145
160
18,716
125-150
165
19,948
125-155
170
21,220
130-160
M105/85
85
5,675
2,014
2,894
1,899
M110/90
90
6,362
2,258
3,244
2,094
M115/90
90
6,362
2,258
3,244
2,258
M120/95
95
7,088
2,516
3,615
2,515
M125/100
100
7,854
2,788
4,006
2,740
M130/105
105
8,659
3,074
4,416
2,974
M135/110
110
9,503
3,374
4,847
3,218
M140/115
115
10,387
3,687
5,297
3,471
M145/115
115
10,387
3,687
5,297
3,687
M150/120
120
11,310
4,015
5,768
4,007
M155/125
125
12,272
4,357
6,259
4,290
M160/130
130
13,273
4,712
6,769
4,582
M165+
M105/95
95
7,088
2,516
3,615
2,516
M110/100
100
7,854
2,788
4,006
2,788
M115/105
105
8,659
3,074
4,416
3,074
M120/110
110
9,503
3,374
4,847
3,374
M125/115
115
10,387
3,687
5,297
3,687
M130/120
120
11,310
4,015
5,768
4,015
M135/125
125
12,272
4,357
6,259
4,357
M140/130
130
13,273
4,712
6,769
4,712
M145/135
135
14,314
5,081
7,300
5,081
M150/140
140
15,394
5,465
7,851
5,465
M155/145
145
16,513
5,862
8,422
5,862
M160/150
150
17,671
6,273
9,012
6,273
M105/80
80
5,027
2,312
3,066
2,271
M110/85
85
5,675
2,610
3,461
2,505
M115/90
90
6,362
2,926
3,881
2,751
M120/90
90
6,362
2,926
3,881
2,926
M125/95
95
7,088
3,261
4,324
3,261
M130/100
100
7,854
3,613
4,791
3,557
M135/105
105
8,659
3,983
5,282
3,849
M140/110
110
9,503
4,372
5,797
4,152
M145/115
115
10,387
4,778
6,336
4,467
M150/115
115
10,387
4,778
6,336
4,778
M155/120
120
11,310
5,202
6,899
5,131
M160/125
125
12,272
5,645
7,486
5,480
M165/130
130
13,273
6,106
8,097
5,841
M105/95
95
7,088
3,261
4,324
3,261
M110/100
100
7,854
3,613
4,791
3,613
M115/105
105
8,659
3,983
5,282
3,983
M120/110
110
9,503
4,372
5,797
4,372
M125/115
115
10,387
4,778
6,336
4,778
M130/120
120
11,310
5,202
6,899
5,202
M135/125
125
12,272
5,645
7,486
5,645
M140/130
130
13,273
6,106
8,097
6,106
M145/135
135
14,314
6,584
8,731
6,584
M150/140
140
15,394
7,081
9,390
7,081
M155/145
145
16,513
7,596
10,073
7,596
M160/150
150
17,671
8,129
10,780
8,129
M165/155
155
18,869
8,680
11,510
8,680
M105/80
80
5,027
2,513
3,318
2,457
M110/85
85
5,675
2,837
3,745
2,710
M115/90
90
6,362
3,181
4,199
2,976
M120/90
90
6,362
3,181
4,199
3,181
M125/95
95
7,088
3,544
4,678
3,544
M130/100
100
7,854
3,927
5,184
3,849
M135/105
105
8,659
4,330
5,715
4,164
M140/110
110
9,503
4,752
6,272
4,492
M145/110
110
9,503
4,752
6,272
4,752
M150/115
115
10,387
5,193
6,855
5,186
M155/120
120
11,310
5,655
7,464
5,551
M160/125
125
12,272
6,136
8,099
5,929
M165/130
130
13,273
6,637
8,760
6,320
M105/95
95
7,088
3,544
4,678
3,544
M110/100
100
7,854
3,927
5,184
3,927
M115/105
105
8,659
4,330
5,715
4,330
M120/110
110
9,503
4,752
6,272
4,752
M125/115
115
10,387
5,193
6,855
5,193
M130/120
120
11,310
5,655
7,464
5,655
M135/125
125
12,272
6,136
8,099
6,136
M140/130
130
13,273
6,637
8,760
6,637
M145/135
135
14,314
7,157
9,447
7,157
M150/140
140
15,394
7,697
10,160
7,697
M155/145
145
16,513
8,256
10,899
8,256
M160/150
150
17,671
8,836
11,663
8,836
M165/155
155
18,869
9,435
12,454
9,435
M105/80
80
5,027
3,519
4,524
3,350
M110/85
85
5,675
3,972
5,107
3,696
M115/85
85
5,675
3,972
5,107
3,972
M120/90
90
6,362
4,453
5,726
4,438
M125/95
95
7,088
4,962
6,379
4,835
M130/100
100
7,854
5,498
7,069
5,248
M135/105
105
8,659
6,061
7,793
5,679
M140/105
105
8,659
6,061
7,793
6,061
M145/110
110
9,503
6,652
8,553
6,590
M150/115
115
10,387
7,271
9,348
7,072
M155/120
120
11,310
7,917
10,179
7,570
M160/125
125
12,272
8,590
11,045
8,085
M165/125
125
12,272
8,590
11,045
8,590
M170/130
130
13,273
9,291
11,946
9,167
M105/95
95
7,088
4,962
6,379
4,962
M110/100
100
7,854
5,498
7,069
5,498
M115/105
105
8,659
6,061
7,793
6,061
M120/110
110
9,503
6,652
8,553
6,652
M125/115
115
10,387
7,271
9,348
7,252
M130/120
120
11,310
7,917
10,179
7,872
M135/125
125
12,272
8,590
11,045
8,518
M140/130
130
13,273
9,291
11,946
9,189
M145/135
135
14,314
10,020
12,882
9,886
M150/140
140
15,394
10,776
13,854
10,608
M155/145
145
16,513
11,559
14,862
11,355
M160/150
150
17,671
12,370
15,904
12,128
M165/155
155
18,869
13,208
16,982
12,927
M170/160
160
20,106
14,074
18,096
13,750
M165+
M170+
larger
diameters at
request
M170+
larger
diameters at
request
M170+
larger
diameters at
request
M170+
larger
diameters at
request
We
Dt
Dg
thread
Le
Dg
Te
Le
We
mm
inches
mm
mm
mm
mm
48
2 1/2
42
162
125
50
52
2 3/4
47
177
135
55
56
3
50
204
155
60
60
3
50
207
155
60
63
3 1/4
55
214
165
64
68
3 1/2
60
227
180
72
Design example
Zone 1
Zone 2
length of anchor = 45 m
Zone 3
Design criteria:
Design ultimate load for anchor, FEd = 2,200 kN
Tie bar length = 45m (calculated in accordance with EN1997)
FEd
Size selection
Minimum Anchor size required Clause 7.2.3 EN1993-5
Serviceability check
Elongation under axial characteristic loading
Ft,ser = 1,600 kN
Stress in shaft =
1,600 x 10 3
4418
Elongation
362 x 45,000
= 79 mm < 100 mm OK
205 x 10 3
OK
10
= 362 N/mm2
fy A s
Mt,ser
500 x 4,418
1.1 x 10 3
OK
72
3 1/2
60
227
180
72
Te
Product
Data
90
4 1/2
75
312
240
90
95
4 3/4
80
332
255
95
100
5
85
340
270
100
105
5 1/4
90
357
275
100
115
5 3/4
100
382
300
115
120
6
105
412
310
120
125
6 1/4
115
440
330
120
130
6 1/2
120
460
340
130
Zone 2
Zone 3
bearing plate
turnbuckle
M105
85
80
link plates
waling
M110
110
5 1/2
95
370
290
110
spherical nut
M105
85
4 1/4
72
289
230
85
80
80
4
66
262
210
80
M105
75
3 3/4
63
248
190
75
main wall
Zone
Description
Environment
Corrosion allowance
Thread
shaft
Thread
shaft
Anchor head
Splash zone,
aggressive
3.75 mm
(from table 4.2 EN1993-5)
107.5
82.5 mm
M110
85 mm
Immediately
behind wall
Non-aggressive compacted
fill, possibility of seawater
entering through connection
to front wall
2.0 mm
(assumed)
79 mm
85 mm
(same bar
as zone 1)
Remainder
of tie bar
Non-aggressive
compacted fill
102.4
77.4 mm
M105
80 mm
Final specification
As a minimum the following information is required in order to specify the anchors correctly.
Anchors:
Grade ASDO500 - M110/85, M100/80 with articulated connections, turnbuckles and length as indicated on drawing
Minimum design resistance, Ft,Rd = 2,200 kN (after corrosion losses)
kt = 0.6 (in accordance with EN1993-5)
fy = 500 N/mm2
fua = 660 N/mm2
Corrosion protection = sacrificial steel to all bars and components as indicated
11
Typical Connections
Connections to sheet piles
Forces are transferred from the sheet pile to the anchor bar
through waling sections that run the length of the wall. At the
front wall these are normally placed behind the wall (i.e. earth
side) and at the anchor wall the non-bearing side.
Anchor wall
connection
Anchor forces
are transferred
directly to the anchor wall via the
waling. Generally
waling bolts are
not required.
Anchor wall
connection
Anchor forces
are transferred
directly to the anchor wall via the
waling. Generally
waling bolts are
not required.
12
Product
Data
13
Connections
Table 4 Standard bearing plates (ASDO500, k t = 0.6)
Nominal thread diameter
Width
Breadth
Thickness
Max. dist. between waling2
wPW
bPW
tPW
Wdist
Metric
mm
mm
mm
mm
64
160
200
30
100
68
160
210
30
100
72
180
230
35
120
76
180
230
40
120
80
180
240
40
120
85
200
250
50
140
90
200
260
55
140
95
200
270
55
140
Width
Breadth
Thickness
Max. dist. between waling2
wPU
bPU
tPU
Wdist
Metric
mm
mm
mm
mm
64
160
170
30
100
68
160
180
30
100
72
180
200
35
120
76
180
200
40
120
80
180
200
40
120
85
200
210
50
140
90
200
210
55
140
95
200
220
55
140
Width
Breadth
Thickness
wPC
bPC
tPC
Metric
mm
mm
mm
64
220
220
30
68
240
240
35
72
250
250
35
76
260
260
35
80
290
290
35
85
300
300
40
90
330
330
40
95
340
340
45
Width
Breadth
Thickness
wPC
bPC
tPC
Metric
mm
mm
mm
64
220
220
30
68
240
240
35
72
250
250
35
76
260
260
35
80
280
280
40
85
300
300
40
90
330
330
45
95
340
340
45
80
128
115
64
85
134
120
68
90
145
130
72
95
151
135
76
Notes: 1. All plates grade S355 and based on the maximum thread capacity for ASDO500, k t = 0.6. For other grades or k t = 0.9.*
2. A waling gap greater than this distance will reduce the capacity of the plate.*
3. Concrete grade assumed at C35/45, plate dimensions will change for different grades of concrete.*
*Please contact our technical department for further information.
Metric
mm
mm
mm
Across corners
Across flats
Depth
64
106
95
51
68
111
100
54
72
117
105
58
76
123
110
61
Min. 0.8
pan width
Dist. between
waling
Dist. between
waling
t
P
PU
PW
14
PW
Product
Data
100
200
270
65
140
105
220
280
70
160
110
220
300
70
160
115
230
300
80
160
120
240
300
80
160
125
130
135
140
145
150
155
160
250
330
90
180
260
330
95
180
270
340
100
180
280
350
100
180
290
370
110
200
290
370
120
200
310
390
120
200
310
390
130
200
100
200
220
65
140
105
220
230
70
160
110
220
240
70
160
115
220
240
80
160
120
220
240
80
160
125
130
135
140
145
150
155
160
240
260
90
180
240
270
95
180
240
270
100
180
240
280
100
180
260
290
110
200
260
300
120
200
260
310
120
200
260
310
130
200
100
350
350
50
105
360
360
50
110
390
390
55
115
410
410
55
120
420
420
60
125
130
135
140
145
150
155
160
450
450
60
460
460
65
490
490
65
500
500
70
520
520
70
540
540
75
550
550
80
580
580
80
100
350
350
50
105
370
370
50
110
390
390
55
115
410
410
55
120
420
420
60
125
130
135
140
145
150
155
160
450
450
60
460
460
65
490
490
70
500
500
70
520
520
70
540
540
75
550
550
80
580
580
80
100
162
145
80
105
168
150
110
110
173
155
120
115
185
165
120
120
190
170
130
125
202
180
130
130
135
140
145
150
155
160
207
185
140
213
190
150
224
200
150
235
210
160
235
210
160
246
220
170
246
220
170
Min. 0.8
pan width
Hexagon and
spherical nuts
Hexagon
Spherical
PC
t
P
PC
PZ
PC
Connections
Table 6 T-Plates for HZ-M-piles (ASDO500, k t = 0.6)
Nominal shaft diameter
Eye ref
Tension plates breadth
Tension plates thickness
Bearing plates breadth
Bearing plates thickness
Bearing plates length
Pin diameter
Metric
inches
mm
mm
mm
mm
mm
mm
bTP
tTP
bPP
tPP
lPP*
48
2 1/2
130
30
110
15
400
50
52
2 3/4
145
30
110
20
400
55
56
3
160
30
140
25
440
60
60
3
170
30
140
25
440
60
63
3 1/4
170
35
140
25
470
64
68
3 1/2
185
40
170
25
550
72
72
3 1/2
185
40
170
25
550
72
52
2 3/4
145
30
250
40
55
56
3
160
30
270
45
60
60
3
170
30
290
45
60
63
3 1/4
170
35
310
50
64
68
3 1/2
190
40
330
50
72
72
3 1/2
190
40
340
55
72
Metric
inches
mm
mm
mm
mm
mm
b1
t1
l2 x b2
t2
48
2 1/2
130
30
230
35
50
Note concrete grade assumed at C35/45, plate dimensions will change for different grades please contact our technical department for information.
All plates grade S355 and based on maximum thread capacity for ASDO500, kt = 0.6. For other grades and kt = 0.9 contact our technical team.
b
lT
lP
bT
P*
l2
b1
t
2
l 1*
b
P
P
TP
Product
Data
75
3 3/4
195
40
190
30
550
75
80
4
225
40
190
30
610
80
85
4 1/4
245
40
200
30
670
85
90
4 1/2
270
40
230
35
700
90
95
4 3/4
285
45
230
35
760
95
100
105
110
115
120
125
130
5
290
50
230
35
810
100
5 1/4
300
50
250
35
860
100
5 1/2
320
55
280
40
880
110
5 3/4
330
60
300
40
940
115
6
345
60
330
40
990
120
6 1/4
365
60
350
40
1060
120
6 1/2
370
65
370
40
1100
130
75
3 3/4
195
40
360
55
75
80
4
225
40
380
60
80
85
4 1/4
245
40
400
65
85
90
4 1/2
270
40
430
70
90
95
4 3/4
285
45
460
70
95
100
105
110
115
120
125
130
5
290
50
480
75
100
5 1/4
300
50
490
75
100
5 1/2
320
55
530
80
110
5 3/4
330
60
550
90
115
6
345
60
570
90
120
6 1/4
365
60
590
95
120
6 1/2
370
65
610
95
130
Other connectors
17
Connections
Table 8 Turnbuckle & coupler (ASDO500, k t = 0.6)
Nominal thread diameter
Diameter
Standard turnbuckle length
Standard turnbuckle adjustment
Long turnbuckle length
Long turnbuckle adjustment
Coupler length
Dt & Dcp
Lt
+/Lt
+/Lcp
Metric
mm
mm
mm
mm
mm
mm
64
95
280
50
480
150
130
68
102
290
50
490
150
140
72
102
295
50
495
150
145
76
108
305
50
505
150
155
80
114
310
50
510
150
225
85
121
320
50
520
150
235
90
127
330
50
530
150
245
95
133
340
50
540
150
255
100
146
350
50
550
150
275
100
760
100
255
240
Turnbuckles with longer adjustment are possible - please contact our sales department for more information.
Metric
mm
mm
mm
mm
LAT
+/WAT
HAT
64
500
100
175
140
68
510
100
180
155
72
540
100
185
165
76
650
100
190
175
80
670
100
195
190
85
680
100
215
195
90
690
100
235
200
95
720
100
240
215
48
2 1/2
30
300
130
50
52
2 3/4
30
335
145
55
56
3
30
390
160
60
60
3
30
390
170
60
63
3 1/4
35
405
170
64
68
3 1/2
40
440
190
72
72
3 1/2
40
440
190
72
75
3 3/4
40
475
195
75
80
4
40
510
225
80
48
2 1/2
330
120
120
50
52
2 3/4
360
130
130
55
56
3
410
140
140
60
60
3
410
140
140
60
63
3 1/4
440
150
150
64
68
3 1/2
480
170
170
72
72
3 1/2
480
170
170
72
75
3 3/4
500
180
180
75
80
4
540
190
190
80
Dg
mm
inches
mm
mm
mm
mm
WLP
LLP
hLP
Dg
mm
inches
mm
mm
mm
mm
LCJ
WCJ
hCJ
All plates grade S355 and based on maximum thread capacity for ASDO500, kt = 0.6. For other grades and kt = 0.9 contact our technical team.
L
t
t
D
Turnbuckle
L
AT
AT
cp
Coupler
18
cp
Articulated turnbuckle
AT
Product
Data
105
152
360
50
560
150
285
110
159
370
50
570
150
295
115
165
380
50
580
150
305
120
171
400
50
600
150
320
125
130
135
140
145
150
155
160
165
178
410
50
610
150
330
191
420
50
620
150
340
191
430
50
630
150
350
203
440
50
640
150
360
203
450
50
650
150
370
216
460
50
660
150
380
216
475
50
675
150
395
229
485
50
685
150
405
241
495
50
695
150
415
105
790
100
260
260
110
810
100
265
270
115
850
100
275
295
120
870
100
280
305
125
130
135
140
145
150
155
160
165
910
100
305
325
900
100
320
320
940
100
325
345
940
100
350
340
970
100
360
365
970
100
370
365
1010
100
380
390
1030
100
380
400
1050
100
415
410
85
4 1/4
40
570
245
85
90
4 1/2
40
625
270
90
95
4 3/4
45
660
285
95
100
105
110
115
120
125
130
5
50
675
290
100
5 1/4
50
705
300
100
5 1/2
55
730
320
110
5 3/4
60
750
330
115
6
60
795
345
120
6 1/4
60
840
365
120
6 1/2
65
860
370
130
85
4 1/4
570
200
200
85
90
4 1/2
610
210
210
90
95
4 3/4
660
220
220
95
100
105
110
115
120
125
130
5
680
240
240
100
5 1/4
700
250
250
100
5 1/2
750
260
260
110
5 3/4
780
270
270
115
6
810
280
280
120
6 1/4
870
290
290
120
6 1/2
910
300
300
130
hC
LP
C
C
LP
hL
Link plates
Cardan joint
19
Walings
Detail Z
Tie bar connection inside sheet pile pan for
additional corrosion protection
Detail Y
Tie bar connection outside sheet pile
(L x 0.72)
L
Detail X
Section on A-A
20
Design
Considerations
Anchor connections to a sheet pile wall
can be made in two ways outside the
wall or inside as shown opposite. Generally walings placed inside the retaining
wall are preferred both for aesthetic
reasons and, in the case of a wall in tidal
or fluctuating water level conditions, to
prevent damage to the waling by floating
craft or vice versa.
Placing the waling inside the wall also
allows the anchor bar to be connected
inside the wall within the pan of a sheet
pile. This greatly increases the corro
sion protection to the main tie bar connection, see detail Z.
When the waling is placed behind the
front wall, it is necessary to use waling
bolts and plates at every point of con
tact between the piles and the waling to
ensure load is transferred fully to the
waling.
Anker Schroeder supply a complete
range of waling bolts to suit project applications. Bolt heads are forged on to
the bar and if these are placed on the
outside of the wall provide greater corrosion protection than exposed threads
such as hexagon nut connections.
For design purposes the waling can
be considered as continuous with allowance being made for end spans.
Although the waling is then statically
indeterminate, it is usual to adopt a
simplified approach where the bending
moment is assumed to be wL2/10, being
the calculated load to be supplied by the
21
esc
fsc
fsc
A
B
af
bsc
2esc
l sc
Splice connections
Section
Modulus
cm3
Section
lsp
mm
hole
pattern
bsp
mm
esp
mm
fsp
mm
Quantity
Bolts
(DIN 7990)
Hex
across flat
mm
UPN180
300
UPN140
560
60
40
60
32
M20 x 45
30
UPN200
382
UPN140
640
60
40
60
32
M20 x 45
30
UPN220
490
UPN160
680
80
40
60
32
M20 x 45
30
UPN240
600
UPN180
740
90
50
75
32
M24 x 50
36
UPN260
742
UPN200
800
110
50
75
32
M24 x 50
36
UPN280
896
UPN220
840
AB
120
50
90
40
M24 x 55
36
UPN300
1070
UPN220
920
AB
120
50
90
40
M24 x 55
36
UPN320
1358
UPN240
1000
AB
130
60
110
40
M30 x 65
46
UPN350
1468
UPN260
1000
AB
140
60
110
40
M30 x 65
46
UPN380
1658
UPN300
1000
AC
180
60
90
48
M30 x 65
46
UPN400
2040
UPN300
1000
AC
180
60
90
48
M30 x 65
46
The above sizes are the most common used other sections can be provided on request.
Port, Reykjavik
22
Waling Bolts
Product Data
Thread pitch
P
Stress area
Asp
Metric
mm
mm2
mm
36
4,0
42
4,5
45
4,5
817
1.121
1.306
55
65
70
48
5,0
1.473
75
52
5,0
1.758
80
56
5,5
60
5,5
64
6,0
2.030
2.362
2.676
85
90
95
Grade
ASDO
Tensile Resistance
accd. EN1993-5
355
kN
200
500
259
355
274
500
355
355
320
500
414
355
361
500
467
355
430
500
557
355
497
500
643
355
578
500
748
355
655
500
848
Forged head of waling bolt placed to outside of sheet pile for increased corrosion resistance
23
Corrosion Protection
Marine structures inherently operate in
aggressive environments and selection
of robust protection systems for tie bars
is key to the longevity of a structure. It
is very important to consider the corrosion protection of the anchors at design
stage and of particular importance is the
connection to the front wall as the anchor is typically subjected to the most
aggressive environment at this point and
this is the most common area of failure
for an anchorage.
Tables 4-1 & 4-2 of EN1993-5 give gui
dance to corrosion allowances for steel
sheet piles, it is accepted practice to
use these same rates for tie bars.
Sacrificial steel
Anker Schroeder consider sacrificial
steel to be the most practical and robust
corrosion protection. The anchor shaft
and thread size are increased in diameter
to allow for corrosion steel loss during
the life of the structure. No additional
coating is required.
75 mm
1.2 mm
Sacrificial corrosion
allowance at head
3.75 mm
The figure below shows how the threaded part of the anchor in the splash zone
has been increased in diameter to allow
for the anticipated corrosion loss. This
system is robust as no special transport
or site considerations are required.
EN1993-5 Table 4-1 Recommended value for the loss of steel thickness (mm) due to corrosion in soils with or without groundwater
M110x6
24
50 years
75 years
100 years
0.55
0.9
1.15
1.4
0.3
1.3
2.3
3.3
4.3
0.55
1.9
3.75
5.6
7.5
0.25
0.9
1.75
2.6
3.5
80
25 years
0.15
M100x6
5 years
M100x6
85
M100x6
Design
Considerations
Wrapping systems
The most commonly used wrapping system is to cover the anchors in a protective
barrier such as petrolatum tape (e.g. Denso).
Anker Schroder can offer factory petrolatum wrapped bar, but it should be remembered, that connections cannot be
wrapped until installed on site and can
increase installation time consider ably.
The vulnerable anchor head can only be
fully protected once installed and this is
often difficult to achieve in site conditions.
It is important to ensure that protection
to connections and the anchor head are
correctly performed during installation,
any damaged or unprotected areas must
be repaired before backfilling.
Galvanising
With the exception of ASDO700 bar
Anker Schroeder tie bars and components can be hot dip galvanised to
EN ISO 1461 but consideration should
be given to threads which are unable
to have more than a nominal coating
of zinc. Please contact our technical
department for further detail.
Painting
Anchors can have any suitable paint
system applied as required by the client.
Consideration should be given to likely
damage that will occur to the paint system during transport and installation as
any break in the protective system could
lead to pitting corrosion.
Please contact our technical department
for further detail.
Galvanised T-plates
Painted anchor
25
Site Information
Storage of anchors
Tie rods and accessories shall be stored
and handled in such a way as to avoid excessive deformation, corrosion, exposure
to heat (e.g. flame cutting), bending or
damage of any kind being caused on the
rods, threaded ends, turnbuckles or nuts.
All threaded parts must be carefully protected from dust, dirt and damage. Clean
and check all threads thoroughly before
use.
No welding or flame cutting shall be carried out on the tie rods and/or accessories (turnbuckles, couplers, nuts) without
written approval of ASDO. All tie bars and
accessories should be protected from
any exposure to heat processes on site
such as welding or flame cutting.
Anchorage Fabrications
Anker Schroeder can also supply anchorage distribution units for more
complex constructions.
26
Assembly
Container or road shipping restrictions
generally mean that anchors are delivered in sections of typically 12 m or
less, however Anker Schroeder have
direct rail links and convenient access
to docks where longer lengths can be
shipped please contact our technical
team for further detail. Sections are
assembled on site to design lengths.
Assembly on a clear hard-standing
with roller trestles is recommended.
Great care should be taken in ensuring
threads are clean and free of dirt and
damage prior to assembling. All threaded connections must be made with minimum engagement of at least 1 x diameter of the thread.
Installation
Anchors should be installed as close as
possible to the line of force that they will
experience during service. Account should
be taken of the additional forces that will
be introduced to the bar by settlement of
the fill, particularly bending at the wall
connection.
Long anchors should be lifted by use of a
stiff lifting beam with supports at approximately every 4-6 m.
Site services & training
Anker Schroeder are able to offer training
for assembly, installation and stressing
either at your site or at our factory in
Dortmund. Please contact our technical
department for more information.
Other products
General
Information
ASDO Stainless
Architectural tie bars
Diameter M12 to M76
ASDO Structural
Architectural tie bars
Diameter M12 to M160
ASDO Ground
Anchors
ASDO Forged
Shackles
Diameters up to
M160 and working
loads > 4,500 kN
Working load
capacities up to
1500 tonnes
This publication provides information and technical details currently used by Anker Schroeder in the manufacture of its products.
Although we have taken great care in the preparation of the data within this publication, we cannot assume responsibility for the
completeness and accuracy of all the details given. Each customer should satisfy themselves of the product suitability for their
requirements. The publication of this data does not imply a contractual offer.
In line with Anker Schroeders policy of continuous improvement the company reserves the right to change or amend details. Please
contact our technical department for further information or to ensure these details are current.
Sustainability
Steel is the most recycled material in construction. All anchorage material supplied by Anker Schroeder is
sourced from reputable steel mills and, where possible, up to 90% of melt is recycled steel. Once a structure has reached the end of its design life Anker Schroeder Bars are 100% recyclable as scrap material but the economics and environmental impact of extraction from the structure need to be considered.
27