DIRECTIONAL CONTROL VALVES

INTRODUCTION

FEATURING:

FLOWS UP TO 290 GPM

PRESSURES UP TO 5000 PSI

UP TO 5 ACTUATORS:
Solenoid, Air, Cam, Lever and Oil

UP TO 12 SPOOL OPTIONS

Low pressure drops to reduce heat


loss and increase efficiency.

VITON seals standard

Compact design

INTERCHANGEABLE SPOOLS
Provide easy field maintenance.
No matching of parts

NO DYNAMIC PUSH-PIN SEAL


Up to 50% greater shifting forces
result at the spool. Higher
malfunction points.

SEALED WET ARMATURE SOLENOIDS


Maximum protection against moisture,
corrosion and dirt.

OPERATOR PROTECTION
High temperature elements are
isolated from direct contact.

STATIC O-RING DESIGN


Eliminates external leakage.
guards against contamination. No
seals to wear out causing
premature valve failure.

2-WIRE LEAD
50/60 Hz code standard for
increased application flexibility.

STANDARD MOUNTINGS
Conforms to NFPA and
ANSI/ISO standards. Orings included.

MOUNTING BOLT
Heads are below spool center line
to reduce body distortion and
spool stick.

LOW CROSS-PORT LEAKAGE


Premium bore honing and spool
grinding results in less leakage,
less energy wasted.

SPOOL "U" GROOVES


Improves contamination tolerance
of spools over conventional "V"
grooves. Significantly reduces
spool hang-up resulting in loss of
production.

TERMINOLOGY AND
GENERAL SPECIFICATIONS
FEATURES

RECOMMENDED OPERATING VISCOSITY

SOLENOID ACTUATED

80 to 350 SUS.

CSA Certified (D03, D05, & D08 sizes).


Wet armature solenoids:
Lead wires or DIN connectors.
Solenoid failures greatly reduced.
Standard and low amp coils available.
High temperature elements are isolated from direct
human contact.
No oil leakage into electrical cavity.
Fast and easy solenoid replacement.
Continuous duty-rated coils.
No dynamic seals eliminate external oil leakages.
Electrical quick disconnects as factory installed or field
installed options.
5-pin sealed connectors per ANSI recommended
standard B93.55M-1981.
Large wiring cavity options for wire to wire connections.
Access to mounting bolts without entering electrical box.
Mounting bolt heads are below spool centerline to prevent
body distortion and spool stick.

FLUID OPERATING VISCOSITY

CAM ACTUATED

Acceptable start-up viscosity to 1500 SUS. Minimum


viscosity to 30 SUS.

FILTRATION
ISO 18/15 (25 micron).

MOUNTING POSITION
Optional: horizontal preferred.

NFPA FLOW PATH/ACTUATING PATTERN


SOLENOID, AIR AND OIL ACTUATED:
Actuating operator a connects flow to cylinder port A.
Actuating operator b connects flow to cylinder port B.
CAM ACTUATED:
Activated connects flow to cylinder port B.
Released connects flow to cylinder port A.
LEVER ACTUATED:
Push connects flow to cylinder port A.
Pull connects flow to cylinder port B.

VC5M cam follower may approach cam from any angle.


VC12M cam follower may be positioned perpendicular or
parallel to mounting surface.
Bearing bronze push-rod for increased life.
Urethane wiper eliminates contamination from actuator.
Actuator internal parts are electro-filmed to resist corrosion.

GENERAL INFORMATION

LEVER ACTUATED

VALVE OPERATION

Spring centered and spring offset valve types will be spring


positioned unless actuated continuously. Detented, no-spring
valves may be actuated momentarily. When operator is
deactuated, the spool will remain shifted provided there is no
severe shock, vibration, or pressure transients.

Lever boot keeps contaminants from linkage.


Lever directly connects to spool for positive spool action.
Detent option for positive hold.
Actuator internal parts are electro-filmed to resist corrosion.

AIR ACTUATED
Wide operating range of air pilot pressures.
Urethane sealing gland on air piston permits very low
air flow rates.
Excellent control of spool shift rate.
Internal parts of air operator are electro-filmed to resist
corrosion.

OIL ACTUATED
Controlled pilot flow will control spool shift rate.
Internal parts of oil operator are electro-filmed to resist
corrosion.
Internal pilot drain.
Wide range for pilot operating pressures.
No dynamic seals eliminate oil leakages.

GENERAL SPECIFICATIONS
RECOMMENDED FLUID
Petroleum, water-based fluids (not more than 40% water)
and most phosphate esters (other fluids are acceptable,
but special O-rings may be required). Viton seals standard.

NOTE:
The NFPA flow path/actuating pattern is reversed for
Spools Code L.

PRESSURE SURGES
Pressure surges in a common tank line serving these and
other valves can be large enough to cause inadvertent
shifting of these valves. This is particularly critical in
no-spring detented type valves. Separate tank lines may be
necessary. Maximum pressure rating on solenoid operated
valve tank ports include surges.

SILTING
Any sliding spool valve, if held shifted under pressure for
long periods of time, may stick and not spring return due to
fluid residue formation. The valve should be cycled
periodically to prevent this from happening.

RESPONSE TIME
Response times of air actuated valves are dependent on air
flow rate and pressure supplied to the operator.
Response times of hydraulic actuated valves will vary with
pilot line diameter and length, pilot pressure, pilot control
valve shift time, pilot oil flow rate, and fluid viscosity.

FLUID TEMPERATURE RANGE


Fluid temperature up to 200F. will not appreciably affect
valve performance, however, from a safety standpoint,
temperatures above 130F. are not recommended.

VS5M

DIRECTIONAL CONTROL VALVES


SOLENOID ACTUATED, DIRECT OPERATED
NFPA SIZE
D03

TYPICAL PERFORMANCE
SPECIFICATIONS
Performance is measured on a four-way circuit
(full circuit). Performance may be reduced from that
shown if a three-way circuit (half circuit) is used,
i.e. A or B port plugged.
NOMINAL FLOW RATE

CSA CERTIFIED

DESCRIPTION
As a valve spool shifts, the spool lands cross over the valve
body ports. This can produce high instantaneous flow rates.
The anti-shock valve provides a slow spool movement;
slower than that of a standard directional valve. This results
in reduction or elimination of hydraulic system shock
produced by the spool movement & high flow rates.

TYPICAL PRESSURE DROP


bar psi

MAXIMUM FLOW RATE

200

4600 psi
1500 psi
3000 psi

315 bar
105 bar
207 bar

INTERNAL
LEAKAGE

(1-port)
4600 psi 100 SUS

3.4 cipm

56 mlpm

MAXIMUM
CYCLE
RATE

AC Solenoids
DC Solenoids

MOUNTING
SURFACE

WEIGHT

PRESSURE DROP

2
150

8
100

50

2
10

6
20

10

30

12

40

14

ANSI/B93.7M-1986 D03
ISO 4401 SIZE 03
Single Actuator
Double Actuator

CS

Viscosities SUS

--

--

--

--

--

--

--

F1

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

SUBPLATE

S (FULL CIRCUIT)

1.25 kg
1.59 kg

A,B,E,F,F1,G,H,J,K,L,N,Q

NOTES:
Pressure rates apply to all valves except with code 68 coils.
Limitations with Code 68L coils are: P, A, B ports.
Max. 1500 psi, 5 gpm max. Code 68L. Recommended
Start-Up Viscosity 40 to 1000 SUS.
Includes surges.
Code P with DC coils only.

Fluid

FLOW CURVE NUMBER


SPOOL SHIFTED
SPOOL CENTERED
P to A or B A or B to T P to A or B A or B to T P to T
2

SPOOL CODES AVAILABLE

2.75 lbs.
3.5 lbs

50

FLOW PATH P CURVES

400 cpm
300 cpm

All pressure drops shown on this data page are


based on 100 SUS fluid viscosity and 0.87 specific
gravity. See the chart below for other viscosities.

FLOW RATE

SPOOL
TYPE

SEE CHART

P, A, B Ports
T port Standard
Code P

MAXIMUM
OPERATING
PRESSURE

12

0
0
gpm 0
lpm 0

27 lpm

16

7 gpm

Multiplier

14.5 20.5
75

100

32

43

54

65

76

86

150

200

250

300

350

400

0.93 1.00 1.11 1.19 1.26 1.32 1.37 1.41

For any other specific gravity (G1) the pressure


drop ( P) will be approximately P1 = P (G1/G).

VS5M

DIRECTIONAL CONTROL VALVES


SOLENOID ACTUATED, DIRECT OPERATED

MAXIMUM FLOW

SPOOL CODE
A
FUNCTION
CODE
1
(lpm)
(70 bar)
@
gpm
1000 psi

2
3, 5
1

(lpm)
(140 bar)
@
gpm
2000 psi

2
3, 5

(lpm)
(210 bar)
@
gpm
3000 psi

1
2
3, 5

(lpm)
(315 bar)
@
gpm
4600 psi

1
2
3, 5

AC

DC

AC

(38)
10
(46)
12
(57)
15
(38)
10
(46)
12
(57)
15
(38)
10
(46)
12
(57)
15
(38)
10
(38)
10
(46)
12

(30)
8
(23)
*6
(57)
15
(38)
8
(23)
*6
(57)
15
(30)
8
(23)
*6
(57)
15
(30)
8
(19)
*5
(46)
12

(38)
10
(46)
12
(46)
12
(38)
10
(46)
12
(46)
12
(38)
10
(46)
12
(46)
12
(38)
10
(46)
12
(46)
12

F
DC

AC

(30)
8
(50)
13
(50)
13
(30)
8
(50)
13
(57)
13
(30)
8
(50)
13

(23)
6
(30)
8

(23)
6
(30)
8

(23)
6
(30)
8

(23)
6
(23)
6

**
(30)
8
(50)
13

F1

DC
(30)
8
(30)
8
(23)
6
(30)
8
(30)
8
(23)
6
(30)
8
(30)
8
**
(23)
6
(30)
8

**

**

J&N

H&Q

AC/DC AC

DC

AC/DC

AC/DC

AC
(27)
7

DC

AC

DC

(27)
7

(38)
10
(27)
7

(30)
8
(27)
7

(50)
13

(50)
13

(38)
10

(50)
13

(23)
6

(38)
10
(23)
6

(30)
8
(23)
6

(50)
13

(46)
12

(23)
6

(19)
5*
(19)
5

(19)
5
(19)
5

(50)
13

(30)
8

(19)
5

(12)
3*

(12)
3

(46)
12

(23)
6

(50) (50)
13
13

(50) (50)
13
13

(50) (38)
10
13

(38) (23)
6
10

(50)
13

(19)
5

(50)
13

(16)
4

(38)
10

(12)
3

Performance is measured on a four-way circuit (full circuit). Performance may be reduced from that shown if a
three-way circuit (half circuit) is used, i.e. A or B port plugged.
NOTES: Valve is not available in this configuration. See page 6.
* 100% of rated voltage required.
** Maximum flow 12 GPM,maximum pressure 2500 PSI
(4600 PSI when used as a pilot valve).
Maximum flow with code 68L solenoids = 5 GPM, 1500 PSI maximum.

VS5M

DIRECTIONAL CONTROL VALVES


SOLENOID ACTUATED, DIRECT OPERATED

SPOOL DESCRIPTION
CENTER POSITION

CROSSOVER

AVAILABLE WITH
FUNCTION CODE

All ports blocked

All ports blocked

1, 2, 3, 5, 6

All ports open

All ports open

1, 2, 3, 5, 6

P & A blocked
B to T

All ports blocked, or


P & A blocked, B to T

3, 5

P blocked
A & B to T

P blocked
A or B to T

1, 2, 3, 5, 6

F1

P blocked
A & B restricted to T

P blocked
A or B restricted to T

1, 3, 5

P to A & B
T blocked

P to A or B
T & A or B blocked

3, 5, 6

P to A & T
B blocked

All ports open

3, 5

P to B
A & T blocked

All ports blocked, or


P to B, A & T blocked

3, 5, 6

P & B blocked
A to T

All ports blocked, or


P & B blocked, A to T

3, 5

P to T
A & B blocked

All ports open,


restricted

3, 5, 6

P to A
B & T blocked

All ports blocked, or


P to A, B & T blocked

3, 5, 6

P to B & T
A blocked

All ports open

3, 5

CODE

SYMBOL

SPOOL FUNCTION

VS5M

DIRECTIONAL CONTROL VALVES


SOLENOID ACTUATED, DIRECT OPERATED

TYPICAL ELECTRICAL AND RESPONSE TIME


VOLTAGE & VOLTAGE RESISTANCE INRUSH HOLDING
SOLENOID CODE FREQUENCY LIMITS
CURRENT CURRENT
10%
LEAD
DIN
(AMPS)
(AMPS)
OHMS
WIRE
CONN. VOLTS - Hz. MIN - MAX
60L

33L

68L

39L

61L

34L

N/A

35L

70L
75L

42L
44L

120 - 60
110 - 50
120 - 60
110 - 50
240 - 60
220 - 50
280 - 60
240 - 50
24 DC
12 DC

108 - 126
99 - 116
108 - 132
99 - 121
216 - 252
198 - 231
252 - 297
216 - 255
21 - 26
10 - 13

36.5

2.10

75.0

1.10

145.0

1.10

197.0

1.00

24.0
6.3

1.00
2.00

NFPA D03 SIZE

HOLDING
POWER

RESPONSE TIME
(MILLISECONDS)

(WATTS) SOLENOID SPRING

.40
.43
.18
.20
.21
.25
.17
.20
1.00
2.00

15
15
28
28
15
15
15
15
30
30

12
14
20
23
12
14
12
14
35
35

21
21
10
9.5
22
22
22
22
24
24

DIMENSIONS SHOWN IN: (MILLIMETERS)


INCHES

(FORMERLY D01)
FOR INTERFACE PATTERN,
SEE MOUNTING SURFACE
SECTION

ACCESS TO MOUNTING BOLTS (4)


TORQUE 4.5 lb.-ft. USE A
5/32 HEX WRENCH

TWO LEAD WIRES FOR EACH


SOLENOID APPROX. (153.0) LONG
6.0
HAND TORQUE ONLY
FOR SOLENOID NUT
(42.2)
1.66
AC SOL
MININUM
CLEARANCE
FOR COIL
REMOVAL
(58.7)
2.31
DC SOL.

(138.2)SINGLE SOLENOID AC
5.44

1/2-14 NPT
ELECTRICAL
CONNECTION
25 ft. lbs.
MAX. TORQUE

(1.5)
.06

OVERRIDE
PIN
(SOLENOID
ENDS ONLY)

(81.0)
(23.9) 3.19
.94
(62.2)
2.45

ORIENTATION PIN
(3.0) DIA. x (3.0) LONG
.12
.12
(22.9)
.90

(77.7) AC SOL.
3.06
(88.1) DC SOL.
3.47
(195.6) DOUBLE SOLENOID AC
7.70
(226.1) DOUBLE SOLENOID DC
8.90

(45.5)
1.79

(153.2) SINGLE SOLENOID DC


6.03
(48.3)
1.90
SOLENOID
"b"

ELECTRICAL
BOX MAY BE
ROTATED 180
SOLENOID
"a"
(16.5)

.65
P
b A B
T

(63.8)
2.51
AC SOL
(79.1)
3.11
DC SOL.

(68.1)
2.68

(6.4)
.25

VS5M

DIRECTIONAL CONTROL VALVES


SOLENOID ACTUATED, DIRECT OPERATED

CODE B5H

CODE C

Quick disconnect for single or double solenoids.


Top electrical box with sealed 5-pin male receptacle.

Low profile electrical box with body grounded coils.

2 LEAD WIRES @
(153.0) LONG APPROX.
6
SOLENOID A
LONG)
SOLENOID B
(SHORT)

(56.1)
2.21

1
2

5
4

PIN NO. WIRE NO. GOES TO:


1
1
SOL. B
2
2
SOL. A
3
(GREEN) GROUND
4
4
SOL. A
5
5
SOL. B

NOTE: 1. Common solenoid grounds (1 wire


each coil) inside electrical box to
valve body.
2. D. C. voltage coils only.

NOTE: 1. Connector meets ANSI


recommended standard B93.55M-1981.

CODES L1 OR L2

CODES 33L THROUGH 44L

Solenoid Indicator Lights.

Solenoid(s) with DIN 43650/ISO 4400


(form A) connector(s).

(91.2)
3.59

(55.9)
2.21 MAX.

(180.3)MAX. DOUBLE
7.10
SOLENOID
SINGLE
(126.7)
4.99 MAX.SOLENOID

(90.7)
3.57
(79.5)
3.13 MAX.

SOLENOID
b

BLACK
PLUG

GREY
PLUG

SOLENOID
a

NOTE: 1. No electrical box required.


2. Order connectors separately (see page 86).
NOTE: 1. Top electrical box required.

VS5M

DIRECTIONAL CONTROL VALVES


SOLENOID ACTUATED, DIRECT OPERATED

ORDERING INFORMATION
SELECT ONE SELECT ONE

VS5M

SELECT ONE

SELECT ONE

SELECT ONE

G
SPOOLS

BASIC VALVE

MECHANICAL
OPTIONS

SEAL

CODE

4-WAY
DIRECTIONAL
CONTROL
VALVE

CODE

OPTION

OMIT

NONE

REFER TO

SOLENOID
ACTIVATED

PAGES
5&6

D03 SUBPLATE
MOUNTING

FOR SPOOL

4600 PSI
MAXIMUM
OPERATING
PRESSURE

SELECT ONE

VITON
SEALS
STANDARD

AVAILABILITY

FOR FUNCTION
CODE
SELECTED

SOLENOID
CODE VOLTAGE
LEAD WIRE
CONNECTIONS

60L

70L

24 VDC

MANUAL
OVERRIDE
ON NONSOLENOID
END

75L

12 VDC

220/240 V
50/60 HZ
110/120 V
50/60 HZ
68L
(LOW AMPS)
61L

SOLENOID(S) WITH DIN


43650/ISO 4400 (FORM A)
CONNECTIONS

33L

WD WASHDOWN

34L

FUNCTION
CODE

DESCRIPTION
b

35L

A B

ELECTRICAL
OPTIONS

SOLENOID INDICATOR
LIGHTS

CODE DESCRIPTION

CODE DESCRIPTION

LEAD WIRE
CONNECTIONS ONLY

LEAD WIRE
CONNECTIONS ONLY

1
P T
Single actuator 2 position
spring offset
b A B
a

2
P T
Double acuator 2 position
no spring, detented
A B
b
a

BT

3
P T
Double actuator 3 position
spring centered
A B
b

B5H

5
P T
Single actuator 2 position
spring centered
A B

TOP
ELECTRICAL
BOX
WITHOUT
TERMINAL
POSTS
TOP
ELECTRICAL
BOX WITH
TERMINALS
& GROUND
TOP
ELECTRICAL
BOX WITH 5
PIN MALE
RECEPTACLE
FOR 1 OR 2
SOLENOIDS
LOW PROFILE
BOX

6
P T
Single actuator 2 position
spring offset,
energize to center

TYPICAL ORDERING CODE:

110/120 V
50/60 HZ

SINGLE
SOLENOID
REVERSE
ASSEMBLY
SOLENOID
"a"
SUPPLIED
3000 PSI
SOLENOID
CORE TUBE

OMIT

L1

L2

NOTES:

NOT
REQUIRED
SINGLE
SOLENOID
INDICATOR
110/120 V
50/60 HZ
12 VDC
24 VDC
DOUBLE
SOLENOID
INDICATOR
110/120 V
50/60 HZ
12 VDC
24 VDC

110/120 V
50/60 HZ
220/240 V
50/60 HZ
240/280 V
50/60 HZ

39L

110/120 V
50/60 Hz.
(LOW AMPS)

42L

24 VDC

44L

12 VDC

Available with DC voltage solenoid codes


only.
Available on single solenoid valves only.
Available with DC voltage, lead wire
solenoids only.
Not Available with Low Profile Box
Code C & Light Option Codes L1 & L2.

VS5M-1A-GB-60L
9

ELECTRICAL ACCESSORIES
FOR DIRECTIONAL CONTROL VALVES

TOP ELECTRICAL BOX

SOLENOID INDICATOR LIGHT

INCLUDES GASKET & MOUNTING SCREWS

INCLUDES GASKET & MOUNTING SCREWS

MODEL SIZE

WEIGHT

(30.5) (46.5) (81.8) (9.9)

CODE 1

1.20 1.83 3.22 .39


(35.0) (69.9) (95.3) (6.4)

CODE 2

1.38 2.75 3.75 .25

SIZE

LBS. / KG.

D03

0.30 / 0.14

D05

0.54 / 0.24

MODEL SIZE

LED display indicates


energized solenoid
and simplfies
troubleshooting.

CODE 1
CODE 2

.38

SIZE LBS. / KG.


D03 0.11 / 0.05
D05 0.20 / 0.09

1.84

3.54

(10.2) (70.1) (106.2)

WEIGHT

1/2 - 14NPT
25 ft. lbs. max. torque

(9.7) (46.7) (89.9)

.40

2.76

4.18

B
C

ORDERING INFORMATION

ORDERING INFORMATION
SELECT
ONE

SELECT
ONE

SELECT
ONE

VEA

SELECT
ONE

SELECT
ONE

VEA

NFPA
CODE VALVE SIZE

CODE

D03

D05

DESCRIPTION
W/O TERMINAL POSTS
OR GROUND
WITH TERMINAL POSTS
& GROUND

CODE

NFPA VALVE
SIZE

D03

SINGLE LIGHT

D05

DOUBLE LIGHT

CODE DESCRIPTION

CODE VOLTAGE
120 V,
1
50/60 HZ
240 V,
2
50/60 HZ
12
12 VDC
24
24 VDC

DIN 43650/ISO 4400 (FORM A) 90


CONNECTOR

QUICK DISCONNECT FOR SINGLE


OR DOUBLE SOLENOID VALVES

FOR USE WITH SOLENOID CODES 33L THROUGH 44L

5-PIN SEALED CONNECTOR MEETS


ANSI STANDARD B93.55M - 1981

(27.5)
1.08

(53.0) MAX.
2.09

MALE RECEPTACLE
1/2-14 NPT MTG thd.
Pre-cut leads with ring terminals

(34.2) MAX.
1.35

ORDERING INFORMATION
SELECT
ONE

SELECT
ONE

WEIGHT: 0.09 lbs. / 0.04 kg.

CODE

DESCRIPTION

GREY CONNECTOR / USED WITH SOL. "A"

BLACK CONNECTOR / USED WITH SOL. "B"

86

1
2

5
4

PIN NO. WIRE NO. GOES TO:


1
1
SOL. B
2
2
SOL. A
3
(GREEN) GROUND
4
4
SOL. A
5
5
SOL. B

ORDERING INFORMATION

VEA

FEMALE PLUG
With 9 ft. cable

VEA
CODE NFPA VALVE SIZE
1C
D03 or D05
3D
D03 or D05
1BC

D03

2BC

D05

Weight: 1.41 lbs. / 0.64 kg.

DESCRIPTION
MALE
FEMALE
FIELD
CONVERSION KIT
FIELD
CONVERSION KIT

NFPA
MOUNTING SURFACES
DIMENSIONS

NOTES: A = Cylinder Port


P = Pressure Port

Mounting surfaces must be flat within 0.1 mm per


100 mm (.0004 in. per 4.0 in.) and N8 63AA) finish.

B = Cylinder Port
X = Pilot Port

T = Tank Port
Y = Drain Port

D03 MOUNTING SURFACE


CONFORMS TO ANSI/B93.7-M-1986, ISO 4401 SIZE 03
M Min.
L
K
J
H
F G
T

C D

A
MIN.

B
P

N
P(4) THD.

Q DIA. x R DP

O DIA.
(4) MAX.

DIMENSIONS
mm
43.0
31.8
31.0
25.9
15.5
5.1

A
B
C
D
E
F

in.
1.70
1.25
1.22
1.02
0.61
0.20

G
H
J
K
L
M

mm
.075
12.7
21.5
30.2
40.5
51.0

in.
0.03
0.50
0.85
1.19
1.594
2.00

N
O
P
Q
R

mm
Z
33.0
1.30
6.3
0.25
10-24 UNC-2B
4.0
.16
4.0
.16

D05 MOUNTING SURFACE


CONFORMS TO ANSI/B93.7-M-1986, ISO 4401 SIZE 05
A Min.
B
C
D
J H

E
F
G
P(4) THD.
P

N
MIN.

K
L

O(4) DIA.
MAX.

DIMENSIONS
A
B
C
D
E

mm
72.1
54.0
37.3
27.0
16.7

in.
2.84
2.13
1.47
1.06
0.66

F
G
H
J
K

mm
3.2
9.1
11.2
6.4
21.4

in.
0.13
0.36
0.44
0.25
0.84

L
M
N
O
P

in.
mm
1.28
32.5
1.81
46.0
2.28
57.9
0.44
11.2
1/4-20 UNC

87

VALVE BOLT KITS


DIRECTIONAL
VALVE

ORDER
CODE

TYPE

LENGTH

BD03-100

BOLT

(25.5)
1.00

(25.5)
1.00

0.05
(0.02)

BD03-250

BOLT

(63.8)
2.50

(63.8)
2.50

0.80
(0.04)

BD03-4125

BOLT

(104.8)
4.125

(104.8)
4.125

0.18
(0.08)

VALVE + (3) (40.0) POLYSTAC BD03-575


1.57

BOLT

(146.0)
5.75

(146.0)
5.75

0.23
0.10)

VALVE + (2)(40.0) POLYSTAC


1.57

BD03-460

STUD

(117.3)
4.60

(106.4)
4.19

0.18
0.08

VALVE + (3)(40.0) POLYSTAC


1.57

BD03-616

STUD

(157.1)
6.16

(146.0)
5.75

0.23
(0.08)

V*12M
DIRECTIONAL VALVE
NFPA D05
KIT:
(4) 1/4-20NC
VALVE + (1)(55.0) POLYSTAC
FASTENERS
2.17
(4) 1/4"
LOCKWASHERS VALVE + (2)(55.0) POLYSTAC
2.17

BD05-175

BOLT

(44.6)
1.75

(44.6)
1.75

0.11
(0.05)

BD05-400

BOLT

(102.0)
4.00

(102.0)
4.00

0.24
(0.10)

BD05-6125

BOLT

(155.6)
6.125

(155.6)
6.12

0.44
(0.20)

VALVE + (3)(55.0) POLYSTAC


2.17

BD05-825

BOLT

(209.6)
8.25

(209.6)
8.25

0.55
(0.25)

VALVE + (2)(55.0) POLYSTAC


2.17

BD05-667

STUD

(170.1)
6.67

(155.2)
6.11

0.44
(0.20)

VALVE + (3)(55.0) POLYSTAC


2.17

BD05-884

STUD

(225.4)
8.84

(210.3)
8.28

0.55
(0.25)

V*50M
DVS50M -- DEACCELATROL
DVS50M
NFPA D08
KIT:
DIRECTIONAL VALVE
(6) 1/2-13NC
FASTENERS
(6) 1/2"
VALVE + (1)(88.9) POLYSTAC
LOCKWASHERS
3.44

BD08-275

BOLT

(70.1)
2.75

(70.1)
2.75

1.25
(0.57)

BD08-275

BOLT

(70.1)
2.75

(70.1)
2.75

1.25
(0.57)

BD08-625

BOLT

(159.4)
6.25

(159.4)
6.25

2.25
(1.02)

VALVE + (1)(101.6) POLYSTAC BD08-675


4.00

BOLT

(172.1)
6.75

(172.1)
6.75

2.40
(1.13)

VALVE STACK

V*5M
DIRECTIONAL VALVE
NFPA D03
KIT:
(4) 10-24NC
VALVE + (1)(40.0) POLYSTAC
FASTENERS
1.57
(4) #10
LOCKWASHERS VALVE + (2)(40.0)POLYSTAC
1.57

EFFECTIVE WEIGHT
LENGTH
lbs. (kg)

VALVE + (2)(88.9) POLYSTAC


3.44

BD08-9625

BOLT

(244.5)
9.625

(244.5)
9.625

3.75
(1.70)

VALVE + (1)(88.9) + (1)(101.6)


POLYSTAC 3.44
4.00

BD08-1020

BOLT

(260.0)
10.25

(260.0)
10.25

4.00
(1.81)

VALVE + (2)(101.6) POLYSTAC BD08-1080


4.00

BOLT

(273.0)
10.75

(273.0)
10.75

4.13
(1.87)

VALVE + (2)(88.9) POLYSTAC


3.44

BD08-1025

STUD

(261.4)
10.25

(247.6)
9.75

3.75
(1.70)

VALVE + (1)(88.9) + (1)(101.6)


POLYSTAC 3.44
4.00

BD08-1075

STUD

(274.1)
10.75

(261.4)
10.25

4.00
(1.81)

VALVE + (2)(101.6 POLYSTAC BD08-1125


4.00

STUD

(286.9)
11.25

(274.1)
10.75

4.13
(1.87)

BOLT

(63.8)
2.50

(63.8)
2.50

2.63
(1.19)

V*100M
DIRECTIONAL VALVE
NFPA D10
KIT:
(6) 3/4-10NC
FASTENERS
(6) 3/4"
LOCKWASHERS

BD10-250

VALVE
F12M
FLOW CONTROL
NFPA 2F06
KIT:
(4) 5/16"-18NC
FASTENERS
(4) 5/16"
LOCKWASHERS

B2F08-225

BOLT

(57.8)
2.25

(57.8)
2.25

0.25
(0.11)

SOCKET HEAD
CAP SCREW

BOLT
LENGTH

STUD NUT

EFFECTIVE
STUD
LENGTH

STUD
Rc 39-45
HARDNESS

DIRECTIONAL
CONTROL
VALVE
POLYSTAC
VALVE

EFFECTIVE
LENGTH

POLYSTAC
VALVE
SUBPLATE/
MANIFOLD

89