Contents
Features .......................................................... 1
Functions ................................................... 2 4
Product Specifications ............................. 5 10
Dimensions ............................................ 11 12
Refrigeration Cycle Diagram ......................... 13
Block Diagram ............................................... 14
Wiring Diagram .............................................. 15
Operation Details ................................... 16 30
Installation Information .......................... 31 32
2-way, 3-way Valves .............................. 33 39
Servicing Information ............................. 40 42
Troubleshooting Guide .......................... 43 44
Technical Data ....................................... 45 48
Exploded View ................................... 49, 51, 53
Replacement Parts List ..................... 50, 52, 54
Electronic Parts List ....................................... 55
1999 Matsushita Air-Conditioning Corp. Sdn. Bhd.
(183914D)
All rights reserved. Unauthorized copying and distribution is a violation of law.
CS-A73KE
! WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain
warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity
should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with
in this service information by anyone else could result in serious injury or death.
Features
High Efficiency
Quality Improvement
Gas leakage protection
Prevent compressor reverse rotation
2-stage OLP to protect compressor
Compact Design
Comfort Enviroment
8 hours of sleep mode operation
Air purifying filter with deodorizing function
to reduce dust, smoke and odours.
Service Improvement
Easy fan motor replacement procedure
Operation Improvement
Economy mode to reduce electrical power
consumption.
Powerful mode to reaches the desired room
temperature quickly.
1
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Functions
Remote Control
OFF / ON I
MODE
FAN SPEED
AUTO
HEAT
COOL
DRY
ON-TIMER
OFF-TIMER
MANUAL
Low Speed
TIMER
Medium Speed
High Speed
SET
CANCEL
AIR SWING
TEMP.
Operation OFF / ON
CLOCK
Clock Setting
Current time setting.
POWERFUL
ECONOMY
2
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Functions
Indoor Unit
POWER I
AUTO
OFF / ON
Anti-Freezing Control
Lights up in operation,
blinks in Automatic
Operation Mode judging
SLEEP (Orange).....
Lights up in Sleep
Mode Operation
TIMER (Orange).....
Lights up in Timer
Setting
POWERFUL (Orange)..... Lights up in Powerful
Mode Operation
ECONOMY (Green)..... Lights up in Economy
Mode Operation
Operation Mode
Powerful Operation
Hot-Start Control
The indoor fan remain stop until the indoor
heat exchanger temperature reaches 30C
The indoor fan will operate at SLo and Lo
when indoor heat exchanger temperature
reaches 30C - 39C
Economy Operation
To reduce electrical power consumption.
3
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Functions
Outdoor Unit
CU-A123KE
CU-A73KE, CU-A93KE
Deice Control
To prevent frosting at outdoor heat
exchanger. (Only for Heating Operation)
Temperature of outdoor heat exchanger is
sensed by TRS (Thermal Reed Switch).
Overload Protector
Inner protector.
4
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Product Specifications
Unit
kW
Btu/h
kW
Btu/h
s/h
Pint/h
Phase
V
Cycle
OUTLET
Cooling Capacity
Heating Capacity
Moisture Removal
Power Source
Airflow Method
CU-A73KE
CS-A73KE
2.20 - 2.10
7,500 - 7,200
2.45 - 2.40
8,360 - 8,200
1.4
3.0
Single
230 - 220
50
SIDE VIEW
TOP VIEW
INTAKE
Air Volume
m3/min (cfm)
m3/min (cfm)
m3/min (cfm)
Outdoor Air
m3/min (cfm)
Noise Level
Electrical
Data
dB (A)
Input
Running Current
A
W/W
COP
Starting Current
Piping Connection Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Inner diameter
Hose
Length
Power Cord Length
Number of core-wire
Height
Dimensions
Width
Depth
Net Weight
Compressor
Type
Motor
Rated
Air Circulation
Motor
Fan
Speed
Type
Output
Type
Material
Type
Input
Rated Output
Low
Medium
High
A
inch
inch
inch
inch
mm
m
m
inch (mm)
inch (mm)
inch (mm)
lb (kg)
W
W
rpm
rpm
rpm
5
Downloaded from www.Manualslib.com manuals search engine
12
0.7
2.0
3 (1.0 mm2)
10-31/32 (279)
18-29/32 (480)
31-15/32 (799)
30-23/32 (780)
7-15/32 (190)
9-21/32 (245)
20 (9.0)
64 (29.0)
Rotary (1 cylinder)
Induction (2-pole)
600
Propeller Fan
Cross-flow Fan
AES + Glass Fiber 12%
AS + Glass Fiber 30%
Induction (6-pole)
Induction (4-pole)
29.0 - 27.0
65.8 - 57.5
10
20
835 - 810
945 - 920
1055 - 1030
730 - 705
CS-A73KE
Product Specifications
Unit
Heat
Exchanger
Description
Tube material
Fin material
Fin Type
Row / Stage
FPI
Size (W H L)
Refrigerant Control Device
mm
Refrigeration Oil
(c.c)
Refrigerant (R-22)
Thermostat
Protection Device
Length
Capillary Tube Flow Rate
Inner Diameter
Material
Air Filter
Style
Capacity Control
Compressor Capacitor
Fan Motor Capacitor
g (oz)
mm
s/min
mm
F, VAC
F, VAC
CS-A73KE
CU-A73KE
Evaporator
Condenser
Copper
Copper
Aluminium
Aluminium
Louver Fin
Slit Fin
(Plate fin configuration, forced draft)
2 14
1 18
18
19
614 294 25.4
856 457.2 22
Capillary Tube
SUNISO 4GDID or
815 (28.8)
Electronic Control
Overload Protector
Honeycomb
Capillary Tube
15 F, 440VAC
1.5 F, 400VAC
1.2 F, 400VAC
6
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Product Specifications
Cooling Capacity
Heating Capacity
Moisture Removal
Power Source
Airflow Method
Unit
kW
Btu/h
kW
Btu/h
s/h
Pint/h
Phase
V
Cycle
CS-A93KE
OUTLET
SIDE VIEW
CU-A93KE
2.80 - 2.70
9,550 - 9,200
3.40 - 3.30
11,590 - 11,250
1.6
3.4
Single
230 - 220
50
TOP VIEW
INTAKE
Air Volume
m3/min (cfm)
m3/min (cfm)
m3/min (cfm)
Outdoor Air
m3/min (cfm)
Noise Level
Electrical
Data
dB (A)
Input
Running Current
A
W/W
COP
Starting Current
Piping Connection Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Inner diameter
Hose
Length
Power Cord Length
Number of core-wire
Height
Dimensions
Width
Depth
Net Weight
Compressor
Type
Motor
Rated
Air Circulation
Motor
Fan
Speed
Type
Output
Type
Material
Type
Input
Rated Output
Low
Medium
High
A
inch
inch
inch
inch
mm
m
m
inch (mm)
inch (mm)
inch (mm)
lb (kg)
W
W
rpm
rpm
rpm
7
Downloaded from www.Manualslib.com manuals search engine
12
0.7
2.0
3 (1.0 mm2)
10-31/32 (279)
18-29/32 (480)
31-15/32 (799)
30-23/32 (780)
7-15/32 (190)
9-21/32 (245)
20 (9.0)
71 (32.0)
Rotary (1 cylinder)
rolling piston type
Induction (2-pole)
800
Cross-flow Fan
Propeller Fan
AS + Glass Fiber 30%
AES + Glass Fiber 12%
Induction (4-pole)
Induction (6-pole)
37.0 - 34.0
65.8 - 57.5
14
20
865 -810
1030 -970
1245 - 1215
730 - 705
CS-A73KE
Product Specifications
Unit
Heat
Exchanger
Description
Tube material
Fin material
Fin Type
Row / Stage
FPI
Size (W H L)
Refrigerant Control Device
mm
Refrigeration Oil
(c.c)
Refrigeration (R-22)
Thermostat
Protection Device
Length
Capillary Tube
Flow Rate
Inner Diameter
Material
Air Filter
Style
Capacity Control
Compressor Capacitor
Fan Motor Capacitor
g (oz)
mm
s/min
mm
F, VAC
F, VAC
CU-A93KE
CS-A93KE
Evaporator
Condenser
Copper
Copper
Aluminium
Aluminium
Slit Fin
Louver Fin
(Plate fin configuration, forced draft)
2 14
1 18
18
19
856 457.2 22
614 294 25.4
Capillary Tube
SUNISO 4GDID or
Electronic Control
Overload Protector
P.P.
Honeycomb
Capillary Tube
25 F, 370VAC
1.5 F, 400VAC
1.2 F, 400VAC
8
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Product Specifications
Cooling Capacity
Heating Capacity
Moisture Removal
Power Source
Airflow Method
Unit
kW
Btu/h
kW
Btu/h
s/h
Pint/h
Phase
V
Cycle
CS-A123KE
OUTLET
SIDE VIEW
CU-A123KE
3.55 - 3.40
12,110 - 11,590
4.20 - 4.05
14,320 - 13,810
2.1
4.4
Single
230 - 220
50
TOP VIEW
INTAKE
Air Volume
m3/min (cfm)
m3/min (cfm)
m3/min (cfm)
Outdoor Air
m3/min (cfm)
Noise Level
Electrical
Data
dB (A)
kW
Input
Running Current
W/W
COP
Starting Current
Piping Connection Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Inner diameter
Hose
Length
Power Cord Length
Number of core-wire
Height
Dimensions
Width
Depth
Net Weight
Compressor
Type
Motor
Rated
Air Circulation
Motor
Fan
Speed
Type
Output
Type
Material
Type
Input
Rated Output
Low
Medium
High
A
inch
inch
inch
inch
mm
m
m
inch (mm)
inch (mm)
inch (mm)
lb (kg)
W
W
rpm
rpm
rpm
9
Downloaded from www.Manualslib.com manuals search engine
12
0.7
2.0
3 (1.0 mm2)
10-31/32 (279)
21-1/4 (540)
31 -15/32 (799)
27-17/32 (699)
7-15/32 (190)
11-7/32 (285)
20 (9.0)
86 (39.0)
Rotary (1 cylinder)
Induction (2-pole)
1,100
Propeller Fan
Cross-flow Fan
AS + Glass Fiber 30%
AES + Glass Fiber 12%
Induction (4-pole)
Induction (6-pole)
35.5 - 33.0
71.0 - 67.0
15
25
1060 -1000
1145 - 1100
1280 - 1260
805 - 780
CS-A73KE
Product Specifications
Unit
Heat
Exchanger
Description
Tube material
Fin material
Fin Type
Row / Stage
FPI
Size (W H L)
Refrigerant Control Device
mm
Refrigeration Oil
(c.c)
Refrigeration (R-22)
Thermostat
Protection Device
Length
Capillary Tube Flow Rate
Inner Diameter
Material
Air Filter
Style
Capacity Control
Compressor Capacitor
Fan Motor Capacitor
g (oz)
mm
s/min
mm
F, VAC
F, VAC
CS-A123KE
CU-A123KE
Evaporator
Condenser
Copper
Copper
Aluminium
Aluminium
Louver Fin
Slit Fin
(Plate fin configuration, forced draft)
2 14
1 20
21
18
614 294 25.4
782.9 508 22
Capillary Tube
SUNISO 4GDID or
990 (34.9)
Electronic Control
Overload Protector
P.P.
Honeycomb
Capillary Tube
30 F, 370VAC
1.5 F, 400VAC
1.5 F, 400VAC
10
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Dimensions
CS-A73KE / CS-A93KE / CS-A123KE
Unit : mm
<Front View>
190
60
36
279
Air intake
direction
799
Left piping
hole
Air outlet
direction
<Side View>
58
60
83
LIQUID SIDE
65
DRAIN PORT
122
TEMP
C
POWERFUL
425
48
Relative position between the indoor unit and the installation plate <Front View>
Slot (2 places)
Slot (2 places)
Centre notch
(40)
17.8
100
350
100
Arrow
Arrow
Centre
Indoor unit
external
dimensions
line
16.5
550
257.2
Installation
plate
(49)
710
(60)
(99)
11
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Dimensions
54
93
780
27.5
CU-A73KE / CU-A93KE
245
480
467
2-way valve at
Liquid side
(High Pressure)
77 67
3-way valve at
Gas side
(Low Pressure)
570
105
280
312
13
105
CU-A123KE
699
100
69
500
99
(52)
32
(120)
162
10 cm
10 cm
100 cm
285
540
7.5
11
67
67
12
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
INDOOR
OUTDOOR
C1
CHECK VALVE
2-WAY
VALVE
C2
C3
INTAKE
TEMP.
SENSOR
PIPE
TEMP.
SENSOR
(T.R.S)
PIPE
TEMP.
SENSOR
HEAT EXCHANGER
(EVAPORATOR)
HEAT EXCHANGER
(CONDENSER)
3-WAY
VALVE
4-WAY VALVE
COMP.
COOLING
HEATING
13
Downloaded from www.Manualslib.com manuals search engine
SINGLE PHASE
AC 220-230V
50Hz
FUSE
2A
TRANSFORMER
CONTROL BOX
TEMP. FUSE
(113C)
FAN
MOTOR
RY-H
RY-SHI
ZNR1
4C
5C
C-FM
RY-M
9C
ZNR1
THERMAL
FUSE
(102C)
CR1
RY-PWR
ELECTRONIC CONTROLLER
CR2
14
CR3
MAIN
POWER SWITCH
Indoor Unit
SSR1
CS-A73KE / CU-A73KE
CS-A93KE / CU-A93KE
CS-A123KE / CU-A123KE
CT1
INTAKE AIR
TEMP. SENSOR
PIPE TEMP.
SENSOR
STEPPING
MOTOR
INDICATOR
P.C.B.
RECEIVER
P.C.B.
CR5
RY-HOT
SSR2
ZNR3
WIRELESS
REMOTE CONTROL
TRANSMITTER
CR
4-WAY
VALVE
A73KEBLD.DWG
CS/CU-A73KE/A93KE
FM
TRS
RELAY
B
CR
RELAY A
Outdoor Unit
COMP
OVERLOAD
PROTECTOR
CS-A73KE
Block Diagram
CS-A73KE
Wiring Diagram
CS-A73KE / CU-A73KE
CS-A93KE / CU-A93KE
CS-A123KE / CU-A123KE
WIRELESS
REMOTE
CONTROL
ELECTRONIC
CONTROLLER
(RECEIVER)
REMOTE
CONTROL No.
B
A
4 5 6 7
CN-DISP(W)
REMARKS:
B
: BLUE
BR : BROWN
BL
: BLACK
W
: WHITE
R
: RED
O
: ORANGE
P
: PINK
Y/G : YELLOW/
GREEN
CN-C
(G)
FAN
MOTOR
1
PUMP DOWN SW
(TEST RUN)
W
CAPACITOR
BR
ELECTRONIC CONTROLLER
BR
MAIN SW
BR
Y/G
CN-DISP(W)
CN-RCV (W)
220-240V, 50/60Hz
POWER SUPPLY CORD
DISPLAY LAMP
CN-FM(G)
1
RY-M
2
3
4
CN-STM(G)
536.5
450.8
457.4
77.1
56.9
56.1
BROWN-ORANGE
43.9
74.2
61.2
ORANGE-WHITE
42.7
37.3
25.3
WHITE-RED
111.4
122.6
142.5
4
CT1
YELLOW-BLUE
BL
BL
CR5
MODEL
CONNECTION
YELLOW-BROWN
SENSOR
(PIPE TEMP.)
TRANSFORMER
FAN
MOTOR
RY-HOT
HOT(R)
AC (W)
SENSOR
(INTAKE TEMP.)
CN-TH(Y)
ZNR1
THERMAL
FUSE
(113C)
SSR1
BR
ZNR2
RY-PWR
RY-SHI
RY-H
CR4
CR3
CR2
CR1
AUTO SW
FM(B)
ZNR3
ELECTRONIC
CONTROLLER
SSR2
CN-FUSE(B)
R
Y/G
BL W
INDOOR UNIT
TERMINAL
OUTDOOR UNIT
TERMINAL
THERMAL
FUSE
(102C)
MODEL
CU-A73KE
CU-A93KE
CU-A123KE
CONNECTION
CWA95245
CWA95381
BLUE-YELLOW
260.5
174.5
YELLOW-RED
446.0
331.0
BL
COIL
REVERSING VALVE
GRY
TRS
BL
BL
GRY
MAGNETIC RELAY B
OVER LOAD
PROTECTOR
BL
2
8
7
BL
BR
4
2
6
8
7
MAGNETIC RELAY A
BL
ELECTROLYTIC
CAPACITOR
GRY
ELECTROLYTIC
CAPACITOR
BL
BL
YELLOW
BLUE
RED
BRAND MARK
COMPRESSOR
4.023
2.798
2.211
C-S
8.803
5.432
2.924
B
CAPACITOR
R
CAPACITOR
J9990083
CS/CU-A73KE/A93KE/A123KE
A73KE07.DWG
FAN MOTOR
15
Downloaded from www.Manualslib.com manuals search engine
CU-A123KE
C-R
B
Y
CU-A93KE
COMPRESSOR TERMINAL
B
CU-A73KE
CS-A73KE
Operation Details
1) Cooling Mode Operation
Cooling in operation according to Remote Control setting.
Indoor Heat
Exchanger
Temperature
(C)
10
Recovery
4 min
Compressor OFF
Compressor
OFF
Compressor
restarts
(3 minutes waiting)
16
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Operation Details
Compressor Protection Control
After the compressor starts for 50 seconds but the outdoor fan motor is still OFF, the compressor will stop and
restart automatically. (Time Delay Safety Control is valid).
Compressor
OFF
Compressor
restarts
(3 minutes waiting)
If the above phenomenon is repeated for 3 times, the compressor will stops.
The above phenomenon is reset when there is a change to heating mode or stopped by Remote Control Switch.
Indoor
Fan
.
.
.. 2
SLo
stop
40"
30"
20"
SLo
SLo
stop
stop
160"
40"
30"
Comp.
ON
OFF
ON
* 1 Fan Speed is Hi until the compressor stops (when the room temperature reaches
setting temperature).
* 2 Fan Speed is Me after the compressor restarts.
* SLo: Indoor Fan rotates at 4 second intervals at low speed.
17
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Operation Details
Cooling Operation Time Diagram
ab c d e f g h i j k l mn o p q r s t u v wx yz
Intake
1.5K
Temperature
ON
Operation
OFF
Stop
Set Temp.
10C
Pipe temperature
2C
Basic Time
Compressor
Indoor Fan
Outdoor Fan
Operation LED
<Description of operation>
dg :
Time Delay Safety Control (waiting for 3 minutes)
gh :
60 sec. Forced Operation
ho :
7 min. Time Saved Control
qt
:
Anti Freezing Control
18
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Operation Details
2) Soft Dry Mode Operation
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote
Control, and then Soft Dry operation will start.
During Soft Dry operation, the Indoor Fan will operate and stop at 4-second intervals at low speed.
The operation will be switched on and off for up to 10 minutes ON and 6 minutes OFF. Once Soft Dry operation is turned off, it stops for 6 minutes.
SLo
Indoor
Fan
Lo
SLo
stop
stop
stop
40"
6'
40"
ON
ON
OFF
COMP
19
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Operation Details
Soft Dry Operation Time Diagram
ab c d e f g h i j k l m n o pq r s t u v
Intake Air
Temperature
Cooling ON
1.5C
Set Temp.
1.0C
Cooling OFF
Soft Dry ON
Soft Dry OFF, ON
10C
Indoor
Heat Exchanger
Temp.
2C
6 1
Basic Time
6 1
6 1 6
Compressor
Indoor Fan
SLo SLo
SLo SLo
Lo SLo SLo
Outdoor Fan
Operation LED
<Description of operation>
a c, p~r
: Cooling Operation
c p, r v : Soft Dry Operation
ef
: Soft Dry OFF
jl
: 60 sec. Forced Operation
qt
: Anti Freezing Control
20
Downloaded from www.Manualslib.com manuals search engine
Operation
Stop
SLo
SLo
CS-A73KE
Operation Details
3) Heating Mode Operation
Heating in operation according to Remote Control setting.
Time Delay Safety Control
When the compressor is stopped by Power Switch or Remote Control, it restarts after 3
minutes when the Power Switch or Remote Control is turned ON.
When the setting temperature is reached during heating operation, the compressor stops and it will not start for
4 minutes.
Indoor Fan stops for 1 minute after 3 minutes compressor stops. Then, it will operate with Lo fan speed for 40
seconds then change to SLo fan speed.
Overload Protection Control
If the temperature of the indoor heat exchanger rises to 51C, Outdoor Fan stops.
The Outdoor Fan restarts when the indoor heat exchanger temperature falls to 49C.
If the indoor heat exchanger becomes 65C or more, the compressor will stop and restart automatically.
(Time Delay Safety Control 4 minutes waiting)
Indoor heat exchanger
temperature 65C
Compressor
OFF
Compressor
restarts
(4 minutes waiting)
Compressor
OFF
Compressor
restarts
(4 minutes waiting)
(C)
123456789012
123456789012
123456789012
Lo
123456789012
34 123456789012
123456789012
123456789012
123456789012
SLo
123456789012
123456789012
30 123456789012
123456789012
Indoor Fan
123456789012
123456789012
OFF
123456789012
21
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Operation Details
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during heating operation.
Fan speed rotates in the range of Me SLo according to the heat exchanger temperature.
( C)
Me
45
( C)
38
Lo
39
30
Lo34
28
SLo
30
15
Heat
Exchanger
Temperature
OFF
39C
Indoor
Heat
34C
Exchanger
30C
Temp.
28C
OFF
Intake
Temp.
ON
3'
Basic time
Compressor
4-way valve
Indoor Fan
Outdoor Fan
Operation LED
1'
40"
30"
SLo SLo
Lo-
Lo-
Lo-
Lo-
SLo SLo
<Description of operation>
a b : Hot start (Indoor fan = OFF)
b d : Hot start (Indoor fan = SLo)
g I : Indoor fan control (controlled during thermostat OFF)
g h : Outdoor fan control (30 sec. Forced Operation) after compressor stops.
Lo-
: Blinking
Operation
Stop
22
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Operation Details
Deicing Control
Deice starts to prevent frosting at outdoor heat exchanger.
Normal Deicing
Deice operation detection commences after 30 minutes of Heating operation starts or 60 minutes after previous deice
operation. If the TRS (Thermal Reed Switch) senses the outdoor piping temperature drops to 3C (TRS CLOSE)
or less for 50 sec. continuosly during compressor is in operation, deice will start.
(There is no detection during Outdoor Fan stops.)
Overload Deicing
During heating operation, if the outdoor Fan OFF duration (due to overload control) is accumulated up to 60 minutes
and after compressor starts for 1 minutes, deicing starts.
Deicing ends when
(a) 12 minutes after deicing operation starts;
(b) TRS senses the outdoor piping temperature rises to 4C (TRS OPEN).
(c) Deicing will not end immediately as time delay (Td) is valid as shown below.
Time taken from deicing starts to TRS OPEN (T)
Td (seconds)
T , 3 minutes
60
120
T> 9 minutes
180
23
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Operation Details
Normal Deicing Time Diagram
a
Indoor
Heat
Exchanger
Temp.
39C
34C
30C
(TRS)
Outdoor
Heat
Exchanger
Temp.
(OPEN)
4C
(CLOSE)
3C
30'
60'
60'
Basic Time
30"
Td
30"
Compressor
4-way Valve
SLo Lo-
Indoor Fan
SLo Lo-
Outdoor Fan
Operation LED
<Description of operation>
ac
: Deicing operation judging condition established
cd
: Deicing operation (timer detected)
d e, l m : Time delay for 4-way valve
e f, m n : Time delay for Compressor
f g, n o : Hot start (no thermo OFF)
g h, o p : No thermo OFF (after finished hot start)
jl
: Deicing operation (TRS detected)
: Blinking
Operation
Stop
51C
Indoor
Heat
Exchanger
Temp.
49C
39C
34C
30C
(OPEN)
(TRS)
4C
Outdoor
(CLOSE)
Heat
3C
Exchanger
Temp.
60
Basic Time
Compressor
4-way Valve
Indoor Fan
SLo Lo
Outdoor Fan
Operation LED
<Description of operation>
a d, k h : Overload Control
dg
: Overload Deicing (timer detected)
gh
: Hot Start (indoor fan OFF)
hi
: Hot Start (indoor fan SLo)
np
: Overload Control (TRS detected)
24
Downloaded from www.Manualslib.com manuals search engine
: Blinking
Operation
Stop
CS-A73KE
Operation Details
4) Automatic Mode Operation
a)
When the Automatic Mode Operation is selected, the indoor fan operates at Lo-- fan speed for 20 second to sense
intake air temperature and determine the 1st operation mode.
Intake
Air
Temperature
b)
Cooling
23C
Soft Dry
20C
Heating
Operation mode will be determine again after 1hour of operation, if the room temperature reaches to set
temperature and compressor off time is over 7 minutes 30 seconds continuously.
* The present operation mode will be continued, if the room temperature does not reach to set temperature
(Compressor keeps running) eventhough after 1 hour from automatic operation mode started.
For 2nd judgement onwards, indoor fan will operate for 25 seconds to sense the intake air temperature for
determining operation mode.
Standard for Determining Operation Mode
2nd Judgement onwards
Present
Mode
Judgement
Cooling
O
(Judgement :
23C & Above)
Next Mode
Soft Dry
Heating
O
(Judgement :
Below 23C)
Cooling
23C Cooling
Heating
Soft Dry
Not Applicable
O
Judgement :
20C & Above)
O
Judgement :
Below 20C)
Heating
Cooling
25C Heating
O
(Judgement :
Above 25C)
Not Applicable
O
(Judgement :
25C & below)
Not Applicable
,Hi
a
(+2C)
27C
24C
23C
a
(0C)
25C
22C
21C
25
Downloaded from www.Manualslib.com manuals search engine
a
9Lo
(-2C)
23C
20C
19C
CS-A73KE
Operation Details
5) Sleep Mode Auto Operation
Cooling or Soft Dry Operation
Approx. 0.5C increase
When you press the SLEEP Mode, the following movement will start
to avoid overcooling.
SETTING
TEMPERATURE
TEMP.
0 1 hour
Sleep Operation button is
pressed
Heating Operation
TEMP.
SETTING
TEMPERATURE
When you press the SLEEP Mode, the following movement will start
to avoid overheating.
0 1 hour
Approx. 2C decrease
1 hour
Approx. 8 hours
after sleep shift
operation starts,
stops
automatically
Approx. 3C decrease
TIME
CS-A73KE
Operation Details
6) Indoor Fan Speed Control
Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is shifted automatically between Stop to SHi depend on
each operation as shown below.
Manual Fan Speed Control
Basic fan speed adjustment (3 setting, from Lo to Hi) can be carried out by using the Fan Speed
Selection button at the remote control.
Tap
Normal
COOLING
Powerful
Economy
SOFT
DRY
Normal
Powerful
Economy
Normal
HEATING
(A73K)
Powerful
Economy
Normal
HEATING
(93K &
A123K)
Powerful
Ecomony
SHi
Hi
Manual
Me
Lo
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Hi
Manual
Me
Lo
LoSLo
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Hi
Manual
Me
Lo
LoSLo
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Hi
O
Lo
RLo
Lo--
SLo
Stop
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
MODE JUDGEMENT
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
27
Downloaded from www.Manualslib.com manuals search engine
Me
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
CS-A73KE
Operation Details
* Lo-- :
* SLo :
* RLo :
Lo
10"
ON
4"
ON
RLo-1"
4"
OFF ON
1"
OFF
36
140.5
Closing
position
Horizontal
Horizontal
Upper limit
Swing up
and down
Upper limit / 0
9
18
27
Lower limit for
Cooling and Soft Dry
Mode / 36
140.5
Closing
position
Horizontal
Upper limit
61
140.5
Closing
position
140.5
Closing
position
Lower limit
for Heating Mode / 61
The left and right airflow direction louvers can be adjusted manually.
28
Downloaded from www.Manualslib.com manuals search engine
Upper limit / 0
10
30
45
Lower limit
for Heating Mode / 61
CS-A73KE
Operation Details
11) Economy Mode Operation
Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner.
However consumer is advised to use Economy Mode operation after the room temperature reaches the desired
temperature.
When the Economy Mode is set, the set temperature will be automatically increased 0.5C against the
present setting temperature. This operation automatically will be running under Random Low Fan Speed.
b) Heating Mode
When the Economy Mode is set, the temperature will be automatically decreased 0.5C against the present
setting temperature.
45
Me
39
Lo
34
Lo-
30
SLo
When the Auto Fan speed is selected, the fan speed will automatically
change from Slo to Me depending to the Indoor piping temperature.
When the manual Fan Speed is selected, the fan speed will automatically change from SLo to Lo, then follows set fan speed when the
Indoor piping temperature reaches 39C
38
30
28
Indoor
piping temp C
15
OFF
29
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Operation Details
12) Powerful Mode Operation
Purpose of this operation is to be obtain the setting temperature quickly.
When the Powerful Mode is set, the set temperature will be automatically decreased 3C against the
present setting temperature. This operation automatically will be running under Super High Fan Speed.
b) Heating Mode
When the Powerful Mode is set, the set temperature will be automatically increased 3C against the present
setting temperature.
*48
Me
* 42
Lo
34
Lo-
30
SLo
When the Auto Fan speed is selected, the fan speed will automatically
change from SLo to Me depending to the Indoor piping temperature.
30
When the manual Fan Speed is selected, the fan speed will automatically change from SLo to Lo, then follows set fan speed when the
Indoor piping temperature reaches 42C.
28
Indoor
piping temp C
38
15
OFF
30
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Installation Information
Attached accessories
No.
Accessories part
Qty.
Installation plate
No.
1
7
Installation plate fixing screw
2
3
Qty.
Band
2
Vinyl tape
Vinyl tape
4
8
Remote control
TEM
POW
OFF
ERF
UL
Battery
4
5
Accessories part
/ON
1
Drain elbow
There should not be any heat source or steam near the unit.
There should not be any obstacles blocking the air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
Indoor unit of this room air conditioner shall be installed on the wall in a height of at least 2.3 m.
OUTDOOR UNIT
If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
There should not be any animal or plant which could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
Do not place any obstacles which may cause a short circuit of the discharged air.
If piping length is over the rated length, additional refrigerant should be added as shown in the table.
Piping size
MODEL
Max.
Common
Length Elevation
(m)
Max.
Piping Additional
Length Refrigerant
(g/m)
(m)
Gas
Liquid
A73KE/A93KE
3/8"
1/4"
7.5
10
20
A123KE
1/2"
1/4"
7.5
15
20
31
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Installation Information
Piping direction
about 1.8 m
<
Right
Right
rear
Left
Right bottom rear
<
Left
Left bottom
Installation plate 1
Sleeve (*)
Bushing-Sleeve (*)
Putty, (Gum Type Sealer) (*)
5 cm or
more
Vinyl tape
8
Vinyl tape 7
Saddle (*)
cm
10 ore
or m
Connecting cable
(3-CORE WIRE/1.5 mm2)
Locally approved cable.
cm
10 ore
or m
cm
100 ore
or m
Saddle (*)
CU-A73KE
CU-A93KE
CU-A123KE
Connecting cable
(3-CORE WIRE/1.5 mm2)
Locally approved cable.
Additional drain hose (*)
10 cm
or more
32
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Valve cap
Flare nut
To
piping
connection
Flare nut
Open position
Closed position
To
piping
connection
Pin
Service
port cap
To outdoor unit
To outdoor unit
Service port
Works
Shaft Position
Shaft Position
Service Port
Shipping
Close
(With valve cap)
Closed
(With valve cap)
Closed
(With cap)
Evacuation
Installation and
Re-installation
Closed
(Counter-Clockwise)
Closed
(Clockwise)
Open
(Push-pin)
Operation
Open
(With valve cap)
Open
(With valve cap)
Closed
(With cap)
Pumping down
(Transferring)
Closed
(Clockwise)
Open
(Counter-clockwise)
Open
(Connected manifold
gauge)
Evacuation
(Servicing)
Open
Open
Open
With vacuum pump
Gas charging
(Servicing)
Open
Open
Open
(With charging cylinder)
Pressure check
(Servicing)
Open
Open
Open
(Connected manifold
gauge)
Gas releasing
(Servicing)
Open
Open
Open
(Connected manifold
gauge)
33
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
1 Evacuation of Installation
WHEN INSTALLING AN AIR CONDITIONER, BE
SURE TO EVACUATE THE AIR INSIDE THE INDOOR
UNIT AND PIPES in the following procedure.
(Indoor unit)
(Liquid side)
(Outdoor unit)
2-way valve
Closed
(Gas side)
3-way valve
OPEN
Closed
Vacuum pump
Lo
Hi
CLOSE
Procedure:
(1) Connect a charging hose with a push pin to the
Low side of a charging set and the service port
of a 3-way valve.
(8) Mount the valve caps onto the 2-way and 3-way
valves.
Caution
If gauge needle does not move from 0 cmHg to
76 cmHg in step (3) above, take the following
measures:
If the leaks stop when the piping connections are
tightened further, continue working from step (3).
If the leaks do not stop when the connections are
retightened, repair the location of the leak.
34
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
2 Pumping down
(Indoor unit)
(Liquid side)
(Outdoor unit)
2-way valve
Closed
(Gas side)
3-way valve
CLOSE
Open
Refrigerant
Reclaiming
Equipment
Lo
Hi
CLOSE
Procedure:
(1) Confirm that both the 2-way and 3-way valves are
set to the opened position.
Remove the valve stem caps and confirm that the valve
stems are in the opened position.
Be sure to use a hexagonal wrench to operate the valve
stems.
Connect the charge hose with the push pin to the Gas
service port.
CS-A73KE
3 Evacuation of Re-installation
If air remain in the indoor unit and refrigeration
pipes, it will affect the compressor, reduce to cooling capacity, and could lead to a malfunction.
(Indoor unit)
(Liquid side)
(Outdoor unit)
2-way valve
Closed
(Gas side)
3-way valve
OPEN
Closed
Vacuum pump
Lo
Hi
CLOSE
Procedure:
(1) Connect a charging hose with a push pin to the
Low side of a charging set and the service port
of the 3-way valve.
36
Downloaded from www.Manualslib.com manuals search engine
Caution
If gauge needle does not move from 0 MPa
(0 cmHg) to 0.1 MPa (76 cmHg) in step (3)
above, take the following measures:
If the leaks stop when the piping connections are
tightened further, continue working from step (3).
If the leaks do not stop when the connections are
retightened, repair the location of the leak.
CS-A73KE
(Indoor unit)
(Liquid side)
(Outdoor unit)
2-way valve
Open
(Gas side)
3-way valve
OPEN
Open
Lo
Refrigerant
Reclaiming
Equipment
Hi
CLOSE
Procedure:
(1) Confirm that both the 2-way and 3-way valves are
set to the open position.
(2) Connect the charge set to the 3-way valves
service port.
(3) Connect the charge sets centre hose to refrigerant reclaiming equipment.
CS-A73KE
5 Evacuation
(No refrigerant in the refrigeration cycle)
(Indoor unit)
(Liquid side)
(Outdoor unit)
2-way valve
Open
(Gas side)
3-way valve
OPEN
Open
Vacuum pump
Lo
Hi
CLOSE
Procedure:
(1) Connect the vacuum pump to the charge sets
centre hose.
(2) Evacuation for approximately one hour.
(3) Close the valve (Low side ) on the charge set, turn
off the vacuum pump, and confirm that the gauge
needle does not move (approximately 5 minutes
after turning off the vacuum pump).
(4) Disconnect the charge hose from the vacuum
pump.
38
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
6 Gas charging
(After Evacuation)
(Indoor unit)
(Liquid side)
(Outdoor unit)
2-way valve
Open
(Gas side)
Check valve
3-way valve
Open
Lo
Charging
cylinder
OPEN
Hi
CLOSE
Procedure:
(1) Connect the charge hose to the charging cylinder.
Open the valve at the bottom of the cylinder and press the
check valve on the charge set to purge the air (be careful
of the liquid refrigerant).
(3) Open the valve (Low side) on the charge set and
charge the system with liquid refrigerant.
(5) Mount the valve stem caps and the service port
cap.
39
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Servicing Information
Tabs
Release hooks
Tab
Control Board
Cover
Fig. 1
Electronic Controller
Intake Air
Sensor
CN-C (GRN)
Hook
CN-FM
(GRN)
Earth Wire
Screw
Indoor Fan Motor removal procedure :1. Remove the control board by:-
Piping
Sensor
(Fig. 2)
Signal
Receiver
Indicator
Fig. 2
Terminal Board
(Unhook)
Left hook
(press down)
Screw
(remove)
CN-STM
right hook
(press up)
Screw
(remove)
Fig. 3
Particular
piece
Tab
Fan motor
Discharge
grille
40
Downloaded from www.Manualslib.com manuals search engine
Fig. 4
CS-A73KE
Servicing Information
Screw
Fan motor
Fig. 5
Evaporator screw
Fig. 6
Evaporator
Push up
evaporator
Bearing
Press the
particular
piece
Fig. 7
41
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Servicing Information
Remote Control Reset
Reset terminal
RES
ET
Remote Control
SW1
Remote Controller
Switch
By adding a jumper wire to the remote control side and a carbon resistor (1/4 W, 10 k) to the indoor printed
circuit board, it is possible to select from 4 types of transmission codes including the condition at time of
delivery condition (1).
Remote control
Switch SW B A
JB
Switch SW1
RX1
At product delivery
Jumper wire
10k
Jumper wire
10k
42
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Troubleshooting Guide
Refrigeration cycle system
Normal Pressure and Outlet Air Temperature (Standard)
Gas pressure
MPa
(kg/cm2G)
Outlet air
temperature
(C)
Cooling mode
0.4 ~ 0.6 (4 ~ 6)
12 ~ 16
Heating Mode
36 ~ 45
Normal
More than 8C
(15 minutes after an
operation is started.)
at the cooling mode
More than 14C
(15 minutes after an
operation is started.)
at the heating mode
Value of electric
current during operation
Dusty condenser
preventing heat radiation
Excessive amount
of refrigerant
Gas side
pressure
Cooling Mode
High
Inefficient compressor
Low
Insufficient refrigerant
Low
Clogged strainer or
capillary tube
Low
Inefficient compressor
Heating Mode
Low
Insufficient refrigerant
Low
Clogged strainer or
capillary tube
43
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Troubleshooting Guide
1. Relationship between the condition of the air conditioner and pressure and
electric current
Cooling Mode
Heating Mode
Low Pressure
High Pressure
Electric
current during
operation
Low Pressure
High Pressure
Electric
current during
operation
Insufficient refrigerant
(gas leakage)
Inefficient
compression
Carry out the measurements of pressure, electric current, and temperature fifteen minutes after an operation is
started.
Insufficient compressing of a
compressor
Symptom
Electric current during operation becomes approximately 20% lower than the
normal value.
The discharge tube of the compressor becomes abnormally hot (normally 70 to 90C).
Electric current reaches a high level abnormally, and the value exceeds the
limit of an ammeter. In some cases, a breaker turns off.
The temperature difference between from the discharge tube to the 4-way valve
and from suction tube to the 4-way valve becomes almost zero.
Locked compressor
44
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
Technical Data
L Thermostat characteristics
CS-A73KE / CS-A93KE / CS-A123KE
Soft Dry
Cooling
(C)
34
(C)
34
32
32
30
30
COMP. ON
Diff. 1.5C
22
24
18
18
20
22
24
26
16
18
20
(C)
34
30
28
COMP. ON
/
/
diff. 2.0C
24
/
32
22
20
18
16
16
18
20
22
Diff. 1.0C
22
24
26
28
Heating
26
16
30 (C)
28
/
/
22
20
16 18
26
20
16
24
24
26
28
30 (C)
45
Downloaded from www.Manualslib.com manuals search engine
Cooling ON
28
Intake Air Temperature
26
28
30
CS-A73KE
Technical Data
L Operation characteristics
CS-A73KE / CU-A73KE
Piping Length Characteristic (Cooling)
Cooling Characteristic
34
36
38
40
42
10
Heating Characteristic
220V
230V
-2
O: Outlet
2.6
2.4
2.2
2.0
1.8
1.38
1.36
1.34
1.32
1.30
5
4
3
2
1
10
46
Downloaded from www.Manualslib.com manuals search engine
34.0
33.8
33.6
33.4
33.2
33.0
LP:
Q:
4
3
2
1
I:
Current (A)
I:
1.3
1.2
1.1
1.0
0.9
1.4
Current (A)
O: Outlet
2.4
2.2
2.0
1.8
1.6
LP:
Q:
220V
230V
36
34
32
30
28
26
-4
O: Outlet
1
44
5
4
3
2
0.65
0.60
0.55
0.50
0.45
LP:
Q:
2.6
2.4
2.2
2.0
1.8
10
32
15
14
13
12
11
30
Current (A)
5
4
3
2
LP:
Current (A)
I:
0.70
0.65
0.60
0.55
0.50
I:
O: Outlet
2.4
2.2
2.0
1.8
16
12
2.6
17
16
15
14
13
Q:
220V
230V
220V
230V
CS-A73KE
Technical Data
L Operation characteristics
CS-A93KE / CU-A93KE
Cooling Characteristic
34
36
38
40
42
O: Outlet
5
10
Heating Characteristic
-4
-2
10
O: Outlet
3.6
3.5
3.4
3.3
3.2
1.50
1.49
1.48
1.47
1.46
5
4
3
2
47
Downloaded from www.Manualslib.com manuals search engine
37.0
36.8
36.6
36.4
36.2
36.0
LP:
Q:
I:
Current (A)
I:
1.4
1.2
1.0
0.8
1.8
1.6
Current (A)
O: Outlet
2.8
2.6
2.4
2.2
3.4
3.2
3.0
LP:
Q:
220V
230V
38
36
34
32
30
28
26
4
3
2
1
LP:
1
5
4
3
2
44
0.65
0.60
0.55
0.50
0.45
Q:
2.8
2.7
2.6
2.5
2.4
10
32
16
15
14
13
12
11
30
Current (A)
5
4
3
2
I:
0.60
0.55
0.50
0.45
0.40
O: Outlet
2.9
2.8
2.7
2.6
2.5
12
17
16
15
14
13
LP:
Q:
I:
220V
230V
220V
230V
CS-A73KE
Technical Data
L Operation characteristics
CS-A123KE / CU-A123KE
Cooling Characteristic
38
40
42
10
12
14
Q:
(220V and 230V)
4.6
4.4
4.2
4.0
3.8
1.6
1.5
1.4
1.3
1.2
10
6
5
4
3
10
12
14
48
Downloaded from www.Manualslib.com manuals search engine
44
43
42
41
40
39
1.7
I:
Current (A)
I:
1.6
1.4
1.2
1.0
0.8
1.8
Current (A)
O: Outlet
3.6
3.4
3.2
3.0
4.6
4.4
4.2
4.0
3.8
LP:
Q:
220V
230V
44
42
40
38
36
34
32
-2
O: Outlet
-4
Heating Characteristic
6
5
4
3
16
LP:
Q:
44
36
O: Outlet
34
6
5
4
3
32
3.8
3.6
3.4
3.2
3.0
LP:
30
16
15
14
13
12
11
0.8
0.7
0.6
0.5
0.4
0.3
Current (A)
5
4
3
2
LP:
Current (A)
I:
0.65
0.60
0.55
0.50
0.45
I:
4.0
3.8
3.6
3.4
3.2
O: Outlet
12
17
16
15
14
13
Q:
220V
230V
220V
230V
16
CS-A73KE
Exploded View
CS-A73KE / CS-A93KE / CS-A123KE
6
5
"
7
#
8
7
3
4
\
:
!
[
<
/
>
@
?
$
%
_
& (
,
&
+
~
(
)
2
{
V
1
8
2
0
]
^
9
9
(Note) : The above exploded view is for the purpose of parts disassembly and replacement.
The non-numbered parts are not kept as standard service parts.
49
Downloaded from www.Manualslib.com manuals search engine
CS-C73KE
CS-A73KE
QTY
1
CS-A73KE
CHASSY COMPLETE
CWD50C338
PARTICULAR PIECE
CWD931019
FAN MOTOR
CWA92288
CWA67C2097
CWH02C060
BEARING
CWH64K007
CWH4580304
CWB30C259
CWH32142
10
CWH50211
11
CWH6002140
12
CWT25005 (3/8)
13
CWE20C610
CS-A93KE
CS-A123KE
@
@
@
@
CWA92286
CWA92290
@
@
@
@
@
@
@
@
@
@
@
@
@
CWE20C624
14
CWE24458
15
VERTICAL VANE
10
CWE24457
16
CONNECTING BAR
CWE26194
@
@
@
17
CWA98260
CWA98C033
18
CWA67C2106
19
CWH52C003
20
HORIZONTAL VANE
CWE24462
CWH10965
21
CONTROL BOARD
22
CWA20C751
23
SLIDE SWITCH
CWA04088
@
@
@
@
@
@
24
ELECTRONIC CONTROLLER
CWA741388
CWA741491
25
RECEIVER
CWA74919
26
INDICATOR COMPLETE
CWA741376`
27
CWA67C2105
28
TERMINAL BOARD
CWA28C575
29
INDICATOR HOLDER
CWD931018
30
SENSOR COMPLETE
CWA50C608
31
CWH13456
32
CWH13457
33
CWA75C723
34
CWH36161
35
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
CWE11C978
36
CWE22C333
37
CWE35C023
38
TAB
CWD931020
39
AIR FILTER
CWD00240
40
GRILLE DOOR
CWE14236
41
XTN4+16C
42
CWH52267
43
DRAIN HOSE
CWH5880580
44
OPERATING INSTRUCTIONS
(ENG/SPA/GER/FRA/NED/ITA)
CWF561595
44a
CWF56195A
44b
CWF56195B
45
INSTALLATION INSTRUCTIONS
CWF61674
46
INSTALLATION PLATE
CWH36157
47
CWH82C144
48
49
(Note)
CWD00C111
CWD00220
All parts are supplied from MACC, Malaysia (Vendor Code: 086).
_ marked parts are recommended to be kept in stock.
* Is an optional parts
50
@
@
@
@
@
@
@
REMARKS
CWB30C260
@
@
@
CWT25007 (1/2)
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
CWA28C576
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
_
_
_
_
_
_
@
@
CWF61685
@
@
@
@
CS-A73KE
Exploded View
CU-A73KE / CU-A93KE
?
>
=
_
<
"
2
+
(
)
&
:
6
/
.
-
$
~
1
8
,
!
9
(Note) : The above exploded view is for the purpose of parts disassembly and replacement.
The non-numbered parts are not kept as standard service parts.
51
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
QTY
CS-A73KE
CS-A93KE
REMARKS
CHASSY ASSY
CWD50K438F
CWD54113
CWH4580399
FAN MOTOR
CWA95245
CWH55027
PROPELLER FAN
CWH00K052
CWH56032
COMPRESSOR
2RS127D3CA04
CWH50077
10
CWH56000
11
CONDENSER
CWB32C043
12
CWH35K017A
13
4-WAY VALVE
CWB00002
14
3-WAY VALVE
CWB01479
15
2-WAY VALVE
CWB02307
16
STRAINER
CWB11025
17
CWT01C638
CWT01C639
18
V COIL COMPLETE
CWA43C424
CWH15266
20
CWG30786
@
@
@
19
21
OVERLOAD PROTECTOR
CWA67C2073
CWA67C2074
22
HOLDER O.L.P
CWH7041200
23
TERMINAL COVER
CWH17006
24
CWH7080300
25
CONTROL BOARD
CWH10881
26
CWA28C500
27
ELECTROLYTIC CAPACITOR
CWA32C045
28
ELECTROLYTIC CAPACITOR
CWA32C067
@
@
@
@
@
@
@
29
CAPACITOR-COMPRESSOR
CWA31653
(15F,440V)
CWA31646
(25F,370V)
30
HOLDER CAPACITOR
CWH30057
31
CWA31342
(1.2F,400V)
@
@
32
ELECTROMAGNETIC SWITCH
CWA00059
33
CWA4711012
34
TEMPERATURE RELAY
CWA14C000
35
CABINET ASSY
CWE00K330A
36
CWE06C117A
37
CWH13C286
38
HANDLE
CWE16037C
(Note)
CWD50K456D
@
@
@
@
@
@
2PS174D3AA02
All parts are supplied from MACC, Malaysia (Vendor Code: 086).
_ marked parts are recommended to be kept in stock.
52
Downloaded from www.Manualslib.com manuals search engine
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
_
_
_
_
_
_
_
_
_
CS-A73KE
Exploded View
CU-A123KE
0
@
3
[
>
|
<
1
9
&
3
{
"
)
/
.
-
!
(
,
6
1
#
$
8
7
(Note) : The above exploded view is for the purpose of parts disassembly and replacement.
The non-numbered parts are not kept as standard service parts.
53
Downloaded from www.Manualslib.com manuals search engine
CS-A73KE
QTY
1
1
6
1
4
CU-A123KE
CWD50K659A
CWD54254
CWH55413
CWA95381
CWH55252
REMARKS
6
7
8
9
10
11
12
13
14
COMPRESSOR
ANTI VIBRATION BUSHING
NUT COMPRESSOR MOUNT
CONDENSER
4-WAY VALVE
TUBE ASS'Y (CHECK VALVE / CAPILLARY)
HOLDER COUPLING ASSY
3-WAY VALVE
2-WAY VALVE
1
3
3
1
1
1
1
1
1
2KS224D5CA02
CWH50055
CWH4582065
CWB32C336
CWB00003
CWT01C652
CWH35K063
CWB01480
CWB02308
15
16
17
18
19
STRAINER
V COIL COMPLETE
SOUND PROOF BOARD
SOUND PROOF MATERIAL
WIRE NET
1
1
1
1
1
CWB11025
CWA43C689
CWH15288
CWG30911
CWD04197A
20
21
1
1
CWD31138
CWA12360
22
23
24
25
26
HOLDER O.L.P.
TERMINAL COVER
NUT TERMINAL COVER
TEMPERATURE RELAY
CONTROL BOARD
1
1
1
1
1
CWH7041200
CWH17006
CWH7080300
CWA14C000
CWH10972
27
28
29
30
1
1
1
1
CWA28C583
CWA32C045
CWA4711012
CWA31647
31
32
HOLDER CAPACITOR
CAPACITOR FAN MOTOR
1
1
33
34
35
36
37
38
39
40
41
ELECTROMAGNETIC SWITCH
ELECTROLYTIC CAPACITOR
PROPELLER FAN ASSY
NUT-PROPELLER FAN
CABINET SIDE PLATE (RIGHT)
CABINET SIDE PLATE (LEFT)
CABINET FRONT PLATE
HANDLE
CONTROL BOARD COVER
2
1
1
1
1
1
1
1
1
(30F, 370 V)
CWH30057
CWA31227
(1.5F, 400 V)
CWA00059
CWA32C067
CWH00K087
CWH56053
CWE04217A
CWE04220A
CWE06K104A
CWE16037C
CWH13461
42
43
1
1
CWD91258
CWE03K035A
(Note)
All parts are supplied from MACC, Malaysia (Vendor Code: 086).
_ marked parts are recommended to be kept in stock.
54
Downloaded from www.Manualslib.com manuals search engine
_
_
_
_
_
_
_
_
CS-A73KE
A48040
A40322
A541SR1544
A54RB501V40
DIODE
DOIDE
FUSE
FUSE HOLDER
INTERGRATED CIRCUIT
INTERGRATED CIRCUIT
INTERGRATED CIRCUIT
INTERGRATED CIRCUIT
INTERGRATED CIRCUIT
A541SS355T
A54CS1VB20E
XBA2C20TR0
XCSCW032
A52D0022G503
A52BR9020F
A52A2003GR2
A52C040
A52C114
Q1
Q2, Q3
Q4
Q5 Q8
RYHOT
TRANSISTOR
TRANSISTOR
TRANSISTOR
TRANSISTOR
ELECTRO MAGNETIC RELAY
A55DC114EKTX
A55C2412KTX
A55D1484K
A55DC143XKTX
A00161
RYPWR
RYSHi , RYHi , RYM
A00106
A00160
TYRISTOR
SLIDE SWITCH
PUSH SWITCH
TRANSFORMER
RESONATOR
DIODE
A56W2DEH1-5
A04085
A01059
A40366
A45CST4.09MG
A54D7.5MT1B
DIODE
SH CAPACITOR
TEMPERATURE FUSE
CURRENT TRANSFORMER
SURGE ABSORBER
ERZVEAV511
A31698
A16C204
A28069T
A59014
D3
DB1
FUSE
FUSE HOLDER
IC1
IC2
IC3
IC4
IC5
SSR1 , SSR2
SW1
SW2 , SW3
T1
X1
ZD1
ZNR1 , ZNR2 , ZNR3
CFM
TEMP FUSE
HOT (RED)
CR1, CR2, CR3, CR4, CR5
(Note)
PART NO.
All parts are supplied from MACC, Malaysia (Vendor Code: 086).
MACC
55
Downloaded from www.Manualslib.com manuals search engine
Printed in Malaysia
P990103000CT
CS-A73K/A93K/A123K
CS-A73K/A93K/A123K
CS-A73K/A93K/A123K
CS-A73K/A93K/A123K
CS-A73KE / CU-A73KE
CS-A93KE / CU-A93KE
CS-A123KE / CU-A123KE
Fig. 1
Fig. 2
Senser (Thermistor)
Characteristics
Intake Air/
Pipe Temp. Data
70
60
MAIN
4.7k
4.7k
4.7k
b
4.7k
P74
P73
P70
P02
INTP1
REMOTE CONTROL
COMMAND INPUT
Vss0
X2
45
T1
10
44
X1
8MHz (27pF X 2)
41
24
INTAKE
AIR TEMP
27
28
29
31
10
9
g
f
12
13
BZ1
14
BZ
15
1
2
3
4
5
AIR SWING
MOTOR
REGULATOR
12
5V
I
+
C2
470
25V
(NHG)
R23
1k
16
BLACK
BLACK
RY-H
+
C3
100
16V
(NHG)
MAGNETIC
RELAY B
IC5
A52A2003GR2
20
30
40
R2
10k
C5
0.022
120
CR1
0.022
120
CR2
0.022
120
CR3
0.022
120
CR4
0.022
BLUE
CS/CU-A73K ( CWA12345 )
RED
BLUE
CAPACITOR
4.7k
10k
e
R4
100k
C5
1
50V
R5
10k
Q2
2SC2412KTX
R3
1.0k
C19
0.01
ZD1
7.5EL1
Q3
2SC2412KTX
RESET SIGNAL
GENERATION
RESET SIGNAL
c GENERATION
BLUE
BLUE
YELLOW
R44
10k
R7
6.2k
50
30
20
10
7
5
3
20
R6
6.2k
BLUE
C7
0.01
1 2 3
40
60
80
100
120
140
RED
TRADE MARK
C-FM
1.5
400V AC
COMPRESSOR
TERMINAL
1
CN-FM
(VH-1)
(GREEN)
IC2
A52BR9020F
1 R/B
RS 8
5
4
C14
0.1
2 Vcc
GND 7
3 CS
D6 6
4 SK
D1 5
R24
10k
CS/CU-A123K ( CWA12360 )
CS/CU-A93K ( CWA12346 )
JX1
2
1
SW2
PUMP DOWN
1
2
3
4
5
R13
10k
C9
0.01
R12
1k
R15
10k
C10
0.01
R14
1k
FAN
MOTOR
SW3
AUTO
(ZH5)
70
FAN
MOTOR
POWER CLOCK c
GENERATOR
34
32
60
MAGNETIC
RELAY A
BROWN
2
RED
50
30
20
10
7
5
3
40
60
80
100
120
140
50
30
20
10
7
5
3
20
50
OLP Characteristics
(Compressor)
YELLOW
Q1
DC114EKTX
C18
10
16V
GRAY
20
40
50
6
RY-M
C15
10
16V
11
(MX-5)
CN-STM
CN-C
(VH-3)
(GREEN)
1
2
3
4
10
Fig.1
PIPE TEMP. SENSOR
(20k 3950)
R26 +
15k
12V
30
C16
10
16V
IC4
78A05
I
ZNR1
511U
AVdc 35
AVref
POWER
26
Temperature (C)
Fig. 3
RED
ELECTROLYTIC CAPACITOR
C4
0.1
36
R27 +
20k
A56W2DEH1-5
BLUE
ANI0 33
25
30
GRAY
R34
150k
40
(PH4)
CN-TH
IC5
78N12H
REGULATOR
C1
3300
35V
(NHG)
ZNR2
511U
R1
5.1k
ANI1
23
ANI2
22
PIPE
TEMP
DEICE
DETECTION
GROUND
21
ANI4
20
ANI3
19
ANI5
18
ANI6
RY-H
17
RESET
RESET
20
R42
10k
WHITE
8MHz
OSC
ANI7
RY-M
P35
VDO1
P34
P36
16
AVss
15
C20
10
16V
XT2 37
P25
14 P33
R29
XT1 38
P23
12 P31
D2
A54MA723TA
+
R43
51k
RY-SHI
DB1
S1VD20
~
+
IC 39
11 P30
-10
COMPRESSOR
D3
A54MA165TA5
C21
0.01
47
46
Vss 42
X1
10
Temperature (C)
48
INTP0 43
IC1
A52D00226506
CAPACITOR
P03
P56
P57
20
YELLOW
BLACK
DISPLAY
P71
FUSE
2.0A
A56W2DEH1-5
BLACK
BLACK
P64
TIMER
SHORTEN
AUTO
OPERATION
P55
SSR2
CR1
CWA59015
RELAY DRIVE
TO50
P65
P66
P40
P67
P41
BUZ
BUZZER
P42
P43
P44
P45
P46
P54
13 P32
C17
0.01
10 VDD0
C22
10
16V
R31
26.1k
R32
102k
P53
P24
PUMP-DOWN
RELAY
DRIVE
SIGNAL
STEPPING MOTOR
DRIVE SIGNAL
AUTO RESTART
AND
RANDOM AUTO RESTART
C23
0.01
R30
24k
SW1
30
10
RY-PWR
R28
10k
10
4
1
WHITE
5
R38 330
R39 330
RX1
11
1 2 3
COIL
REVERSING VALVE
4
R37 330
JX2
12
RY-PWR
P47
R36 330
RED
13
P52
RY-SHI
ORG
14
SSR2
15
SSR1
P51
SCK30
ORG
P50
SO30
SLEEP
2
R35 330
SI30
6
5
4
3
2
1
A54LNK3171B
TIMER
OFF/ON
RY-HOT
(MX-9)
CN-DISP
1
2
3
4
5
6
7
8
9
(PH-6)
CN-DISP
RELAY DRIVE
CN-FUSE1
ZNR2
ERZ-TCEAK471
Intake Air
Temp. Data
BLACK
Q5
A55DC143XKTX
16
A54LNK2172B
GRN
RY-SHI
RY-H
RY-M
SSR1
RY-HOT
SSR2
RELAY DRIVE
1 2 3
AC
(WHT)
FM
(BLU)
CT1
CWA40322
RY-HOT
CWA00161
TRS
INDICATOR
ORG
10k
Q6
A55DC143XKTX
10k
R41
10k
ECONOMY
HOT
(RED)
RELAY DRIVE
R45
10k
POWERFUL
CN-FUSE2
Q8
A55DC143XKTX
10k
Q7
A55DC143XKTX
40
BLACK
c
b
OVER LOAD
PROTECTOR
10k
c
R21
6.2k
50
Resistance (k )
b
R22
2.2k
Q4
2SD148-4X
SSR1
R8
1k
BROWN
RY-PWR
D1
ERA15-01
TEST
R9
10k
1
2
3
4
TEMPERATURE
FUSE
113C
YELLOW
RY-PWR DRIVE
C11
0.01
6.3V
47
+
137k
FO 4
TEMPERATURE
FUSE
102C
ORANGE
VCC2 3
5 GND
POWER
SUPPLY
SWITCH
RED
OUT 2
6 CO
0.01
0.01
R16
5.1k
BLUE
330
7 IN-
R17
1k
1
2
3
WHITE
VCC1 1
8 IN+
1
2
3
4
AC 220-230V
50/60Hz
SINGLE PHASE
(PH3)
CN-RCV
PH302C
ELECTROLYTIC
CAPACITOR
RECEIVER
Voltage (V)
10
11
6/19/00, 10:52 AM
12
13
14
15
40
60
80
100
120
140
16
17
18
19
CS-A73K/A93K/A123K
C1
47
R11
510k
R03
x2
+ C2
47
C9
0.01
R9
200k
R5
2.2
1/8W
R3
51
Q2
2SD602
7 min.
42 sec.
4 min.
Mode Jugdement
Soft Dry
R6
300
C6
0.1
(CLOSE:ON)
SW2
R12
51k
0 sec.
6 min.
36 sec.
On
10 min.
40 sec
60 sec.
4 sec.
Cooling
70 sec.
7 sec.
20 sec.
2 sec.
180 sec.
18 sec.
40 sec.
4 sec.
360 sec.
36 sec.
5 min.
30 sec.
Deodorizing Control
Soft Dry
2 min.
0 sec.
1.6 sec.
0 sec.
8 sec.
8 sec.
16 min.
96 sec.
15 min.
15 sec.
5 sec.
5 sec.
0 ~ 150 sec.
0 sec
VDD
COM0
COM1
COM2
SEG0
SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
OSC1
SEG 7 64
SEG8 63
SEG9 62
SEG10 61
21 PC3
SEG11 60
22 PC2
SEG12 59
23 PC1
SEG13 58
IC1
24 PC0
Remarks
R13
51k
R14
51k
SEG14 57
25 PA0
SEG15 56
26 PA1
SEG16 55
27 PA2
SEG17 54
28 PA3
SEG18 53
SEG19 52
29 PA4
SEG20 51
30 PA5
SEG21 50
31 PA6
32 PA7
0 sec.
20 sec.
Off
(POWERFUL)
FAN SPEED
(TEMP )
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
SEG22 49
SEG 23
48
SELF
DIAGNOSIS
SLEEP
TIMER
ON
AIR SWING
AUTO
TIMER
OFF
TIMER
CANCEL
TIMER
SET
MODE
(TEMP )
CLOCK
SW2
0
ECONOMY
AIR SWING
MANUAL
(OFF / ON)
aI
0 sec.
SEG24
60 sec.
Forced Operation
SEG25
0 sec.
SEG26
2 min. 58 sec.
SEG27
1 sec.
SEG28
1 min.
SEG29
10 sec.
SEG30
10 min.
Real Timer
10
SEG31
1 min.
11
SEG32
6 sec.
48 sec.
12
20 RESET
RMO
test point
( When
Short-circuited )
1 hr.
13
19 VSS
DOOR OPEN/CLOSE
SW1
J-B
1 hr.
14
17 XOSC2
18 XOSC1
Test mode
Time
15
VLCD3
OSC2
X2
32.768kHz
VLCD2
C5
8P
(NPO)
TIMER TABLE
8 hrs.
R7
200k
X1
3.52Hz
(33P x 2)
R1
100k
RESET
Name
R8
200k
R2
1.5k
R4
22k
16
BOTTOM VIEW
C4
8P
(NPO)
TOP VIEW
CN1
VLCD1
15C
PRINT PATTERN
INDOOR UNIT PRINTED CIRCUIT BOARD
C8
0.01
BZ
17C
Q1
2SB710
PC7
16C
CS-A73K/A93K/A123K
C7
0.01
LED1
SID1003BQ
PC6
27C
PRINT PATTERN
INDOOR UNIT PRINTED CIRCUIT BOARD
REMOTE CONTROL
PC5
Cooling
PC4
CS-A73K/A93K/A123K
CS-A73K/A93K/A123K
J-B
OFF
ON
OFF
SHORT
ON
SHORT
10
11
6/19/00, 10:53 AM
12
13
14
15
16
17
18
19