You are on page 1of 58

ORDER NO.

MAC9902015C2

Service Manual
Room Air Conditioners

CS-A73KE / CU-A73KE
CS-A93KE / CU-A93KE
CS-A123KE / CU-A123KE

Contents

Features .......................................................... 1
Functions ................................................... 2 4
Product Specifications ............................. 5 10
Dimensions ............................................ 11 12
Refrigeration Cycle Diagram ......................... 13
Block Diagram ............................................... 14
Wiring Diagram .............................................. 15
Operation Details ................................... 16 30
Installation Information .......................... 31 32
2-way, 3-way Valves .............................. 33 39
Servicing Information ............................. 40 42
Troubleshooting Guide .......................... 43 44
Technical Data ....................................... 45 48
Exploded View ................................... 49, 51, 53
Replacement Parts List ..................... 50, 52, 54
Electronic Parts List ....................................... 55
1999 Matsushita Air-Conditioning Corp. Sdn. Bhd.
(183914D)
All rights reserved. Unauthorized copying and distribution is a violation of law.

Downloaded from www.Manualslib.com manuals search engine

CS-A73KE
! WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain
warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity
should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with
in this service information by anyone else could result in serious injury or death.

! PRECAUTION OF LOW TEMPERATURE


In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigeration circuit.

Features
High Efficiency

Quality Improvement
Gas leakage protection
Prevent compressor reverse rotation
2-stage OLP to protect compressor

Compact Design
Comfort Enviroment
8 hours of sleep mode operation
Air purifying filter with deodorizing function
to reduce dust, smoke and odours.

Service Improvement
Easy fan motor replacement procedure

Operation Improvement
Economy mode to reduce electrical power
consumption.
Powerful mode to reaches the desired room
temperature quickly.

Random Auto Restart


Auto restart at randomly after power failure

Removable and Washable


Front Panel

Long Installation Piping


CS/CUA73KE, CS/CUA93KE, long piping up to 10
meter.
CS/CUA123KE, long piping up to 15 meter.

1
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Functions
Remote Control

OFF / ON I

MODE

Operation Mode Selection

FAN SPEED

AUTO
HEAT
COOL
DRY

Automatic Operation Mode


Heating Operation Mode
Cooling Operation Mode
Soft Dry Operation Mode

ON-TIMER
OFF-TIMER

MANUAL

Temperature Setting (16C to 30C)


Automatic Operation
Operation with 2C higher than
8 HI
standard temperature.
a
Operation with standard
a
temperature.
a
Operation with 2C lower than
9 Lo
standard temperature.

Timer Operation Selection

Low Speed
TIMER

Medium Speed

Time / Timer Setting


Hours and minutes setting.

High Speed
SET
CANCEL

Automatic Fan Speed

Timer Operation Set / Cancel


ON Timer and OFF Timer setting and
cancellation.

Airflow Direction Control


AUTO

Room Temperature Setting

24-hour, OFF / ON Real Timer Setting.

Indoor Fan Speed Selection


h j k
l
h j k
lll
h j k
lllll
AUTO FAN

AIR SWING

TEMP.

Operation OFF / ON

Automatic Airflow Direction


Control
Airflow Direction Manual Control

CLOCK

Clock Setting
Current time setting.

POWERFUL

Powerful Mode Operation OFF/ON


SLEEP

ECONOMY

Economy Mode Operation OFF/ON

2
Downloaded from www.Manualslib.com manuals search engine

Sleep Mode Operation OFF / ON

CS-A73KE

Functions
Indoor Unit

POWER I

Power Switch OFF / ON

AUTO
OFF / ON

Random Auto Restart Control


Operation is restarted randomly after power
failure at previous setting mode.

Auto Operation Button

Anti-Freezing Control

Used when the remote control cannot be


used.

Anti-Freezing control for indoor heat


exchanger. (Cooling and Soft Dry)

Remote Control Signal Receiving


Sound

Sleep Mode Auto Control


Indoor Fan operates at low speed.
Operation stops after 8 hours.

It can be controlled by pressing Auto


Operation Button for 10 seconds.
TEST RUN
OFF / ON

Indoor Fan Speed Control

Operation Test Running / Pump


Down Switch
Used when test running or servicing.

Operation Indication Lamps (LED)


POWER (Red)......

Lights up in operation,
blinks in Automatic
Operation Mode judging
SLEEP (Orange).....
Lights up in Sleep
Mode Operation
TIMER (Orange).....
Lights up in Timer
Setting
POWERFUL (Orange)..... Lights up in Powerful
Mode Operation
ECONOMY (Green)..... Lights up in Economy
Mode Operation

Airflow Direction Control


Automatic air swing and manual adjusted
by remote control for vertical airflow.
Manually adjusted by hand for horizontal
airflow.

Starting Current Control

Operation Mode

Time Delay Safety Control

Heating, Cooling, Soft Dry and


Automatic Mode.

Restarting is inhibited for appro. 3 minutes.

7 Minutes Time Save Control

Powerful Operation

Cooling Operation only.

Reaches the desired room temperature


quickly.

Hot-Start Control
The indoor fan remain stop until the indoor
heat exchanger temperature reaches 30C
The indoor fan will operate at SLo and Lo
when indoor heat exchanger temperature
reaches 30C - 39C

Economy Operation
To reduce electrical power consumption.

3
Downloaded from www.Manualslib.com manuals search engine

High, Medium and Low.


Automatic Fan Speed Mode
Heating
: Fan speed varies from Me
SLo in accordance with indoor
heat exchanger.
Cooling
: Fan rotates at Hi and Me
speed. Deodorizing control is
available.
Soft Dry
: Fan rotates at SLo speed.
Deodorizing control is available.

CS-A73KE

Functions
Outdoor Unit

CU-A123KE

CU-A73KE, CU-A93KE

Compressor Reverse Rotation


Protection Control

Deice Control
To prevent frosting at outdoor heat
exchanger. (Only for Heating Operation)
Temperature of outdoor heat exchanger is
sensed by TRS (Thermal Reed Switch).

To protect compressor from reverse


rotation when there is a instantaneous
power failure.

Overload Protection Control

Overload Protector

Outdoor fan stops when indoor heat


exchanger temperature rises to 51C and
above, and restarts when the indoor heat
exchanger temperature drops to 49C and
below.
Compressor stop when indoor heat exchanger temperature reaches 65C or
above. (Heating Operation Only)

2-Stage OLP to protect the compressor.


Overload Protector will trip when
Temperature of compressor increases to
120C.
High temperature or high current flows to
compressor.
(Refer circuit diagram for OLP
characteristic)

Compressor Protection Control


60 Secs. Forced Operation Control
Once the compressor is activated, it does
not stop within the first 60 secs. However, it
stops immediately with remote control stop
signal.

Outdoor Fan Operation Control

If the outdoor fan motor is not running after


compressor starts for 50 secs., compressor
will stop. (Cooling and Soft Dry Operation
only).

4-Way Valve Control


When the unit is switched to "OFF" during
Heating Operation, 4-way valve stays at
Heating position for 5 minutes.

Inner protector.

Outdoor Fan Motor Control

4
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Product Specifications
Unit
kW
Btu/h
kW
Btu/h
s/h
Pint/h
Phase
V
Cycle
OUTLET

Cooling Capacity
Heating Capacity
Moisture Removal
Power Source

Airflow Method

CU-A73KE

CS-A73KE
2.20 - 2.10
7,500 - 7,200
2.45 - 2.40
8,360 - 8,200
1.4
3.0
Single
230 - 220
50
SIDE VIEW

TOP VIEW

INTAKE

Air Volume

Indoor Air (Lo)

m3/min (cfm)

Indoor Air (Me)

m3/min (cfm)

Indoor Air (Hi)

m3/min (cfm)

Outdoor Air

m3/min (cfm)

Noise Level
Electrical
Data

dB (A)
Input

Running Current

A
W/W

COP
Starting Current
Piping Connection Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Inner diameter
Hose
Length
Power Cord Length
Number of core-wire
Height
Dimensions
Width
Depth
Net Weight
Compressor
Type
Motor
Rated
Air Circulation
Motor

Fan
Speed

Type
Output
Type
Material
Type
Input
Rated Output
Low
Medium
High

A
inch
inch
inch
inch
mm
m
m
inch (mm)
inch (mm)
inch (mm)
lb (kg)

W
W
rpm
rpm
rpm

5
Downloaded from www.Manualslib.com manuals search engine

Cooling ; 5.9 (206) - 5.7 (200)


Heating ; 6.7 (238) - 6.6 (233)
Cooling ; 6.7 (237) - 6.4 (227)
Heating ; 7.6 (269) - 7.5 (265)
Cooling ; 7.5 (260) - 7.2 (250)
Heating ; 8.5 (300) - 8.4 (300)

27.8 (981) - 26.8 (946)

Cooling ; High 34/33, Low 29/27


Cooling ; High 47/45
Heating ; High 36/35, Low 30/28
Heating ; High 49/47
Cooling ; 700 - 680
Heating ; 640 - 600
Cooling ; 3.6 - 3.5
Heating ; 3.4 - 3.2
Cooling ; 3.14 - 3.09
Heating ; 3.83 - 4.00
15.5
G ; 3-way valve 3/8"
G ; Half Union 3/8"
L ; 2-way valve 1/4"
L ; Half Union 1/4"
G (gas side) ; 3/8"
G (gas side) ; 3/8"
L (liquid side) ; 1/4"
L (liquid side) ; 1/4"

12
0.7

2.0

3 (1.0 mm2)

10-31/32 (279)
18-29/32 (480)
31-15/32 (799)
30-23/32 (780)
7-15/32 (190)
9-21/32 (245)
20 (9.0)
64 (29.0)
Rotary (1 cylinder)

rolling piston type

Induction (2-pole)

600
Propeller Fan
Cross-flow Fan
AES + Glass Fiber 12%
AS + Glass Fiber 30%
Induction (6-pole)
Induction (4-pole)
29.0 - 27.0
65.8 - 57.5
10
20
835 - 810

945 - 920

1055 - 1030
730 - 705

CS-A73KE

Product Specifications
Unit
Heat
Exchanger

Description
Tube material
Fin material
Fin Type
Row / Stage

FPI
Size (W H L)
Refrigerant Control Device

mm

Refrigeration Oil

(c.c)

Refrigerant (R-22)
Thermostat
Protection Device
Length
Capillary Tube Flow Rate
Inner Diameter
Material
Air Filter
Style
Capacity Control
Compressor Capacitor
Fan Motor Capacitor

g (oz)

mm
s/min
mm

F, VAC
F, VAC

CS-A73KE
CU-A73KE
Evaporator
Condenser
Copper
Copper
Aluminium
Aluminium
Louver Fin
Slit Fin
(Plate fin configuration, forced draft)
2 14
1 18
18
19
614 294 25.4
856 457.2 22

Capillary Tube
SUNISO 4GDID or

ATMOS M60 (290)

815 (28.8)

Electronic Control

Overload Protector

Cooling ;850, Heating ;360

Cooling ;4.5, Heating ;10.5

Cooling ;1.1, Heating ;1.3


P.P.

Honeycomb
Capillary Tube

15 F, 440VAC
1.5 F, 400VAC
1.2 F, 400VAC

Specifications are subject to change without notice for further improvement.

6
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Product Specifications

Cooling Capacity
Heating Capacity
Moisture Removal
Power Source

Airflow Method

Unit
kW
Btu/h
kW
Btu/h
s/h
Pint/h
Phase
V
Cycle

CS-A93KE

OUTLET

SIDE VIEW

CU-A93KE
2.80 - 2.70
9,550 - 9,200
3.40 - 3.30
11,590 - 11,250
1.6
3.4
Single
230 - 220
50
TOP VIEW

INTAKE

Air Volume

Indoor Air (Lo)

m3/min (cfm)

Indoor Air (Me)

m3/min (cfm)

Indoor Air (Hi)

m3/min (cfm)

Outdoor Air

m3/min (cfm)

Noise Level
Electrical
Data

dB (A)
Input

Running Current

A
W/W

COP
Starting Current
Piping Connection Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Inner diameter
Hose
Length
Power Cord Length
Number of core-wire
Height
Dimensions
Width
Depth
Net Weight
Compressor
Type
Motor
Rated
Air Circulation

Motor

Fan
Speed

Type
Output
Type
Material
Type
Input
Rated Output
Low
Medium
High

A
inch
inch
inch
inch
mm
m
m
inch (mm)
inch (mm)
inch (mm)
lb (kg)

W
W
rpm
rpm
rpm

7
Downloaded from www.Manualslib.com manuals search engine

Cooling ; 6.4 (226) - 5.9 (209)


Heating ; 6.8 (240) - 6.5 (228)
Cooling ; 7.6 (269) - 7.1 (251)
Heating ; 8.1 (286) - 7.7 (273)
Cooling ; 9.2 (320) - 8.9 (310)
Heating ; 9.8 (350) - 9.7 (340)

27.8 (981) - 26.8 (946)

Cooling ; High 39/38, Low 29/28


Cooling ; High 49/48
Heating ; High 39/39, Low 30/28
Heating ; High 49/47
Cooling ; 980 - 950
Heating ; 885 - 870
Cooling ; 4.6 - 4.6
Heating ; 4.2 - 4.2
Cooling ; 2.86 - 2.84
Heating ; 3.84 - 3.79
22
G ; Half Union 3/8"
G ; 3-way valve 3/8"
L ; Half Union 1/4"
L ; 2-way valve 1/4"
G (gas side) ; 3/8"
G (gas side) ; 3/8"
L (liquid side) ; 1/4"
L (liquid side) ; 1/4"

12

0.7

2.0

3 (1.0 mm2)
10-31/32 (279)
18-29/32 (480)
31-15/32 (799)
30-23/32 (780)
7-15/32 (190)
9-21/32 (245)
20 (9.0)
71 (32.0)

Rotary (1 cylinder)
rolling piston type

Induction (2-pole)

800
Cross-flow Fan
Propeller Fan
AS + Glass Fiber 30%
AES + Glass Fiber 12%
Induction (4-pole)
Induction (6-pole)
37.0 - 34.0
65.8 - 57.5
14
20

865 -810

1030 -970
1245 - 1215
730 - 705

CS-A73KE

Product Specifications
Unit
Heat
Exchanger

Description
Tube material
Fin material
Fin Type
Row / Stage

FPI
Size (W H L)
Refrigerant Control Device

mm

Refrigeration Oil

(c.c)

Refrigeration (R-22)
Thermostat
Protection Device
Length
Capillary Tube
Flow Rate
Inner Diameter
Material
Air Filter
Style
Capacity Control
Compressor Capacitor
Fan Motor Capacitor

g (oz)

mm
s/min
mm

F, VAC
F, VAC

CU-A93KE
CS-A93KE
Evaporator
Condenser
Copper
Copper
Aluminium
Aluminium
Slit Fin
Louver Fin
(Plate fin configuration, forced draft)
2 14
1 18
18
19
856 457.2 22
614 294 25.4
Capillary Tube

SUNISO 4GDID or

ATMOS M60 (350)


935 (33.0)

Electronic Control
Overload Protector

Cooling ; 1,075, Heating ; 325

Cooling ; 5.0, Heating ; 13.4

Cooling ; 1.2, Heating ; 1.4

P.P.

Honeycomb
Capillary Tube

25 F, 370VAC
1.5 F, 400VAC
1.2 F, 400VAC

Specifications are subject to change without notice for further improvement.

8
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Product Specifications

Cooling Capacity
Heating Capacity
Moisture Removal
Power Source

Airflow Method

Unit
kW
Btu/h
kW
Btu/h
s/h
Pint/h
Phase
V
Cycle

CS-A123KE

OUTLET

SIDE VIEW

CU-A123KE
3.55 - 3.40
12,110 - 11,590
4.20 - 4.05
14,320 - 13,810
2.1
4.4
Single
230 - 220
50
TOP VIEW

INTAKE

Air Volume

Indoor Air (Lo)

m3/min (cfm)

Indoor Air (Me)

m3/min (cfm)

Indoor Air (Hi)

m3/min (cfm)

Outdoor Air

m3/min (cfm)

Noise Level
Electrical
Data

dB (A)
kW

Input
Running Current

W/W

COP
Starting Current
Piping Connection Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Inner diameter
Hose
Length
Power Cord Length
Number of core-wire
Height
Dimensions
Width
Depth
Net Weight
Compressor
Type
Motor
Rated
Air Circulation

Motor

Fan
Speed

Type
Output
Type
Material
Type
Input
Rated Output
Low
Medium
High

A
inch
inch
inch
inch
mm
m
m
inch (mm)
inch (mm)
inch (mm)
lb (kg)

W
W
rpm
rpm
rpm

9
Downloaded from www.Manualslib.com manuals search engine

Cooling ; 7.5 (263) - 7.0 (247)


Heating ; 8.0 (281) -7.5 (266)
Cooling ; 8.1 (284) - 7.7 (271)
Heating ; 8.6 (303) - 8.3 (293)
Cooling ; 9.0 (320) - 8.8 (310)
Heating ; 9.6 (340) - 9.5 (340)

35.0 (1,236) - 32.8 (1,193)

Cooling ; High 39/39, Low 34/33


Cooling ; High 49/48
Heating ; High 39/39, Low 33/32
Heating ; High 49/48
Cooling ; 1.24 - 1.20
Heating ; 1.17 - 1.13
Cooling ; 5.6 - 5.6
Heating ; 5.2 - 5.2
Cooling ; 2.86 - 2.83
Heating ; 3.59 - 3.58
26
G ; Half Union 1/2"
G ; 3-way valve 1/2"
L ; Half Union 1/4"
L ; 2-way valve 1/4"
G (gas side) ; 1/2"
G (gas side) ; 1/2"
L (liquid side) ; 1/4"
L (liquid side) ; 1/4"

12

0.7

2.0

3 (1.0 mm2)
10-31/32 (279)
21-1/4 (540)
31 -15/32 (799)
27-17/32 (699)
7-15/32 (190)
11-7/32 (285)
20 (9.0)
86 (39.0)
Rotary (1 cylinder)

rolling piston type

Induction (2-pole)

1,100
Propeller Fan
Cross-flow Fan
AS + Glass Fiber 30%
AES + Glass Fiber 12%
Induction (4-pole)
Induction (6-pole)
35.5 - 33.0
71.0 - 67.0
15
25

1060 -1000

1145 - 1100
1280 - 1260
805 - 780

CS-A73KE

Product Specifications
Unit
Heat
Exchanger

Description
Tube material
Fin material
Fin Type
Row / Stage

FPI
Size (W H L)
Refrigerant Control Device

mm

Refrigeration Oil

(c.c)

Refrigeration (R-22)
Thermostat
Protection Device
Length
Capillary Tube Flow Rate
Inner Diameter
Material
Air Filter
Style
Capacity Control
Compressor Capacitor
Fan Motor Capacitor

g (oz)

mm
s/min
mm

F, VAC
F, VAC

CS-A123KE
CU-A123KE
Evaporator
Condenser
Copper
Copper
Aluminium
Aluminium
Louver Fin
Slit Fin
(Plate fin configuration, forced draft)
2 14
1 20
21
18
614 294 25.4
782.9 508 22

Capillary Tube
SUNISO 4GDID or

ATMOS M60 (410)

990 (34.9)

Electronic Control

Overload Protector

Cooling ;1,100, Heating ;470

Cooling ;6.0, Heating ; 13.4

Cooling ; 1.3, Heating ; 1.5

P.P.

Honeycomb
Capillary Tube

30 F, 370VAC
1.5 F, 400VAC
1.5 F, 400VAC

Specifications are subject to change without notice for further improvement.

10
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Dimensions
CS-A73KE / CS-A93KE / CS-A123KE
Unit : mm

<Front View>

190

60

36

279

Air intake
direction

799

Left piping
hole

Air outlet
direction

Right piping hole


<Side View>
60

<Side View>

58

60

83

Remote control transmitter


<Back View>
65
18
GAS SIDE

LIQUID SIDE

65

DRAIN PORT

122

TEMP
C

POWERFUL

425

48

Relative position between the indoor unit and the installation plate <Front View>
Slot (2 places)
Slot (2 places)

Centre notch
(40)

17.8

100

350

100

Arrow
Arrow

Centre

Right piping hole

Indoor unit
external
dimensions
line

16.5

550

257.2

Installation
plate

(49)

710

(60)

(99)

Left piping hole

11
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Dimensions

54

93

780

27.5

CU-A73KE / CU-A93KE

245

480
467

2-way valve at
Liquid side
(High Pressure)
77 67

3-way valve at
Gas side
(Low Pressure)

570

105

280
312

13

105

CU-A123KE
699
100

69

500

99

(52)

32

Space necessary for


installation

(120)

162

10 cm

10 cm

100 cm

Anchor Bolt Pitch


323 x 500

285

540

7.5

2-Way Valve at Liquid side


(High Pressure)

11

67

67

3-Way Valve at Gas side


(Low Pressure)
(323)
347

12
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Refrigeration Cycle Diagram


CS-A73KE / CU-A73KE
CS-A93KE / CU-A93KE
CS-A123KE / CU-A123KE

INDOOR

OUTDOOR

C1
CHECK VALVE

2-WAY
VALVE

C2

C3

INTAKE
TEMP.
SENSOR

PIPE
TEMP.
SENSOR
(T.R.S)

PIPE
TEMP.
SENSOR

HEAT EXCHANGER
(EVAPORATOR)

HEAT EXCHANGER
(CONDENSER)

3-WAY
VALVE

4-WAY VALVE

COMP.

COOLING
HEATING

13
Downloaded from www.Manualslib.com manuals search engine

SINGLE PHASE
AC 220-230V
50Hz

FUSE
2A

TRANSFORMER

CONTROL BOX
TEMP. FUSE
(113C)

Indicates the electronic control unit.

FAN
MOTOR

RY-H

RY-SHI

ZNR1

4C

5C

C-FM

RY-M

9C

"C" Indicates the number of core wires. (Example:6C=6 core wires).

ZNR1

THERMAL
FUSE
(102C)

CR1

RY-PWR

ELECTRONIC CONTROLLER

CR2

14

CR3

Downloaded from www.Manualslib.com manuals search engine


CR4

MAIN
POWER SWITCH

Indoor Unit

SSR1

CS-A73KE / CU-A73KE
CS-A93KE / CU-A93KE
CS-A123KE / CU-A123KE

CT1

INTAKE AIR
TEMP. SENSOR

PIPE TEMP.
SENSOR

STEPPING
MOTOR

INDICATOR
P.C.B.

RECEIVER
P.C.B.

CR5

RY-HOT

SSR2
ZNR3

WIRELESS
REMOTE CONTROL
TRANSMITTER

CR

4-WAY
VALVE

A73KEBLD.DWG

CS/CU-A73KE/A93KE

FM

TRS

RELAY
B

CR

RELAY A

Outdoor Unit

COMP

OVERLOAD
PROTECTOR

CS-A73KE

Block Diagram

CS-A73KE

Wiring Diagram
CS-A73KE / CU-A73KE
CS-A93KE / CU-A93KE
CS-A123KE / CU-A123KE
WIRELESS
REMOTE
CONTROL

ELECTRONIC
CONTROLLER
(RECEIVER)

REMOTE
CONTROL No.
B
A

4 5 6 7
CN-DISP(W)

REMARKS:
B
: BLUE
BR : BROWN
BL
: BLACK
W
: WHITE
R
: RED
O
: ORANGE
P
: PINK
Y/G : YELLOW/
GREEN

CN-C
(G)

FAN
MOTOR
1

PUMP DOWN SW
(TEST RUN)

W
CAPACITOR

BR

ELECTRONIC CONTROLLER

BR

MAIN SW

BR

Y/G

CN-DISP(W)

CN-RCV (W)

220-240V, 50/60Hz
POWER SUPPLY CORD

DISPLAY LAMP

CN-FM(G)
1

RY-M

2
3
4

CN-STM(G)

Resistance of Indoor Fan Motor Windings

536.5

450.8

457.4

77.1

56.9

56.1

BROWN-ORANGE

43.9

74.2

61.2

ORANGE-WHITE

42.7

37.3

25.3

WHITE-RED

111.4

122.6

142.5

4
CT1

CS-A73KE CS-A93KE CS-A123KE


CWA92288 CWA92296 CWA92290

YELLOW-BLUE

BL

BL
CR5

MODEL
CONNECTION
YELLOW-BROWN

SENSOR
(PIPE TEMP.)

TRANSFORMER

FAN
MOTOR

RY-HOT

HOT(R)

AC (W)

SENSOR
(INTAKE TEMP.)

CN-TH(Y)

ZNR1

THERMAL
FUSE
(113C)

SSR1

FUSE T2A L250V

BR

ZNR2

RY-PWR

RY-SHI

RY-H

CR4

CR3

CR2

CR1

AUTO SW

FM(B)
ZNR3
ELECTRONIC
CONTROLLER

SSR2

CN-FUSE(B)
R

Y/G
BL W

Resistance of Outdoor Fan Motor Windings

INDOOR UNIT
TERMINAL

OUTDOOR UNIT
TERMINAL

THERMAL
FUSE
(102C)

MODEL

CU-A73KE

CU-A93KE

CU-A123KE

CONNECTION

CWA95245

CWA95381

BLUE-YELLOW

260.5

174.5

YELLOW-RED

446.0

331.0

BL

COIL
REVERSING VALVE

GRY

TRS
BL

BL

GRY

MAGNETIC RELAY B

OVER LOAD
PROTECTOR

BL
2

8
7
BL
BR
4

2
6

8
7

MAGNETIC RELAY A

BL

ELECTROLYTIC
CAPACITOR

GRY

ELECTROLYTIC
CAPACITOR

BL
BL

YELLOW

Resistance of Compressor Windings


MODEL

BLUE

RED
BRAND MARK

COMPRESSOR

4.023

2.798

2.211

C-S

8.803

5.432

2.924

B
CAPACITOR
R

CAPACITOR

J9990083
CS/CU-A73KE/A93KE/A123KE
A73KE07.DWG

FAN MOTOR

15
Downloaded from www.Manualslib.com manuals search engine

CU-A123KE

C-R

B
Y

CU-A93KE

CONNECTION 2RS127D3CA04 2PS174D3AA02 2KS224D5CA02

COMPRESSOR TERMINAL
B

CU-A73KE

CS-A73KE

Operation Details
1) Cooling Mode Operation
Cooling in operation according to Remote Control setting.

Time Delay Safety Control (3 minutes)


When the compressor is stopped by Power Switch or Remote Control, it restarts after 3 minutes when the Power
Switch or Remote Control is turned ON.
When the setting temperature is reached during cooling operation, the compressor stops and it will not start for 3
minutes.

7 minutes Time Saved Control


The compressor will start automatically if it has stopped for 7 minutes if the room temperature is between the
compressor ON temperature and OFF temperature.

Starting Current Control


When the compressor, outdoor fan motor & indoor fan motor are simultaneously started, the indoor fan motor will
operate 1.6 second later.
Anti-Freezing Control
If the temperature of the indoor heat exchanger
falls continously below 2C for 4 minutes or more,
the compressor turns off to protect the indoor heat
exchanger from freezing. The fan speed setting
remains the same.

Indoor Heat
Exchanger
Temperature
(C)
10

Recovery

4 min

Compressor recommences when the indoor heat


exchanger temperature rises to 10C (Recovery).
* 3 minutes waiting of Time Delay Safety Control
is valid for Cooling Operation.

Compressor OFF

Compressor Reverse Rotation


Protection Control
If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake
air and indoor heat exchanger is 2.5C or less for 2 minutes, compressor will stop and restart automatically.
(Time Delay Safety Control is valid).

Compressor starts for > 5 minutes


T < 2.5C for 2 minutes

Compressor
OFF

Compressor
restarts
(3 minutes waiting)

T = Intake air temperature Indoor heat exchanger temperature


This is to protect reverse rotation of the compressor when there is a instantaneous power failure.

16
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Operation Details
Compressor Protection Control
After the compressor starts for 50 seconds but the outdoor fan motor is still OFF, the compressor will stop and
restart automatically. (Time Delay Safety Control is valid).

Comp. operates for 50 secs.


and
Fan Motor OFF

Compressor
OFF

Compressor
restarts
(3 minutes waiting)

If the above phenomenon is repeated for 3 times, the compressor will stops.
The above phenomenon is reset when there is a change to heating mode or stopped by Remote Control Switch.

Automatic Fan Speed Mode


When Automatic Fan Speed is selected at Remote Control during cooling operation.
Fan speed rotates in the range of Hi to Me.
Deodorizing Control.
.
.
.. 1
SLo

Indoor
Fan

.
.
.. 2
SLo

stop
40"

30"

20"

SLo

SLo

stop

stop

160"

40"

30"

Comp.
ON

OFF

ON

* 1 Fan Speed is Hi until the compressor stops (when the room temperature reaches
setting temperature).
* 2 Fan Speed is Me after the compressor restarts.
* SLo: Indoor Fan rotates at 4 second intervals at low speed.

17
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Operation Details
Cooling Operation Time Diagram

ab c d e f g h i j k l mn o p q r s t u v wx yz
Intake
1.5K
Temperature

ON

Operation

OFF

Stop

Set Temp.

10C
Pipe temperature
2C

Basic Time

Compressor
Indoor Fan
Outdoor Fan
Operation LED
<Description of operation>
dg :
Time Delay Safety Control (waiting for 3 minutes)
gh :
60 sec. Forced Operation
ho :
7 min. Time Saved Control
qt
:
Anti Freezing Control

18
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Operation Details
2) Soft Dry Mode Operation
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote
Control, and then Soft Dry operation will start.
During Soft Dry operation, the Indoor Fan will operate and stop at 4-second intervals at low speed.
The operation will be switched on and off for up to 10 minutes ON and 6 minutes OFF. Once Soft Dry operation is turned off, it stops for 6 minutes.

Time Delay Safety Control


Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Starting Current Control
Same as Starting Current Control for Cooling Mode operation.
Anti-Freezing Control
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during
compressor stops.)
Compressor Reverse Rotation
Protection Control
Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6
minutes waiting is valid during compressor stops.)
Compressor Protection Control
Same as Compressor Protection Control for Cooling Mode Operation.
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during Soft Dry Operation.
Fan speed rotates at SLo and Lo speed.
Deodorizing Control.

SLo
Indoor
Fan

Lo

SLo

stop

stop

stop

40"

6'

40"

ON

ON
OFF

COMP

* SLo: Indoor Fan rotates at 4-second intervals at low speed.

19
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Operation Details
Soft Dry Operation Time Diagram

ab c d e f g h i j k l m n o pq r s t u v
Intake Air
Temperature
Cooling ON
1.5C
Set Temp.
1.0C

Cooling OFF
Soft Dry ON
Soft Dry OFF, ON

10C
Indoor
Heat Exchanger
Temp.
2C

6 1

Basic Time

6 1

6 1 6

Compressor
Indoor Fan

SLo SLo

SLo SLo

Lo SLo SLo

SLo SLo SLo

Outdoor Fan
Operation LED
<Description of operation>
a c, p~r
: Cooling Operation
c p, r v : Soft Dry Operation
ef
: Soft Dry OFF
jl
: 60 sec. Forced Operation
qt
: Anti Freezing Control

20
Downloaded from www.Manualslib.com manuals search engine

Operation
Stop

SLo

SLo

CS-A73KE

Operation Details
3) Heating Mode Operation
Heating in operation according to Remote Control setting.
Time Delay Safety Control
When the compressor is stopped by Power Switch or Remote Control, it restarts after 3
minutes when the Power Switch or Remote Control is turned ON.
When the setting temperature is reached during heating operation, the compressor stops and it will not start for
4 minutes.
Indoor Fan stops for 1 minute after 3 minutes compressor stops. Then, it will operate with Lo fan speed for 40
seconds then change to SLo fan speed.
Overload Protection Control
If the temperature of the indoor heat exchanger rises to 51C, Outdoor Fan stops.
The Outdoor Fan restarts when the indoor heat exchanger temperature falls to 49C.
If the indoor heat exchanger becomes 65C or more, the compressor will stop and restart automatically.
(Time Delay Safety Control 4 minutes waiting)
Indoor heat exchanger
temperature 65C

Compressor
OFF

Compressor
restarts
(4 minutes waiting)

Compressor Reverse Rotation


Protection Control
If the compressor is operating continuously for 5 minutes or longer and temperature difference between intake air
and indoor heat exchanger is 5C or less for 2 minutes, compressor will stop and restart automatically.
(Time Delay Safety Control is valid).
Compressor starts for 5 minutes
T < 5C for 2 minutes

Compressor
OFF

Compressor
restarts
(4 minutes waiting)

T = Indoor heat exchanger temperature intake air temperature


This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
4-way Valve Control
4-way valve always ON during Heating operation.(Except Deicing operation)
When the unit is switched to "OFF" during Heating operation, 4-way valve stays at Heating position for 5 minutes.
Outdoor Fan Motor Control
When compressor stop (reaches room temperature), outdoor fan will operate for 30 seconds.
(30 seconds Forced Operation).
Hot Start Control
When Heating operation starts, Indoor Fan will not start until the indoor heat exchanger reaches 30C as diagram
123456789012
123456789012
shown.
Indoor heat
exchanger

(C)

123456789012
123456789012
123456789012
Lo
123456789012
34 123456789012
123456789012
123456789012
123456789012
SLo
123456789012
123456789012
30 123456789012
123456789012
Indoor Fan
123456789012
123456789012
OFF
123456789012

Hot Start is completed when indoor heat exchanger reaches 39C.

21
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Operation Details
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during heating operation.
Fan speed rotates in the range of Me SLo according to the heat exchanger temperature.

( C)
Me
45

( C)
38
Lo

39
30

Lo34

28

SLo
30

15
Heat
Exchanger
Temperature

If use Manual Fan Speed,

OFF

at above diagram will operate with setting Fan Speed.

Heating Operating Time Diagram

39C
Indoor
Heat
34C
Exchanger
30C
Temp.
28C
OFF
Intake
Temp.

ON
3'

Basic time
Compressor
4-way valve
Indoor Fan
Outdoor Fan
Operation LED

1'

40"

30"

SLo SLo

Lo-

Lo-

Lo-

Lo-

SLo SLo

<Description of operation>
a b : Hot start (Indoor fan = OFF)
b d : Hot start (Indoor fan = SLo)
g I : Indoor fan control (controlled during thermostat OFF)
g h : Outdoor fan control (30 sec. Forced Operation) after compressor stops.

Lo-

: Blinking
Operation
Stop

22
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Operation Details
Deicing Control
Deice starts to prevent frosting at outdoor heat exchanger.
Normal Deicing
Deice operation detection commences after 30 minutes of Heating operation starts or 60 minutes after previous deice
operation. If the TRS (Thermal Reed Switch) senses the outdoor piping temperature drops to 3C (TRS CLOSE)
or less for 50 sec. continuosly during compressor is in operation, deice will start.
(There is no detection during Outdoor Fan stops.)
Overload Deicing
During heating operation, if the outdoor Fan OFF duration (due to overload control) is accumulated up to 60 minutes
and after compressor starts for 1 minutes, deicing starts.
Deicing ends when
(a) 12 minutes after deicing operation starts;
(b) TRS senses the outdoor piping temperature rises to 4C (TRS OPEN).
(c) Deicing will not end immediately as time delay (Td) is valid as shown below.
Time taken from deicing starts to TRS OPEN (T)

Td (seconds)

T , 3 minutes

3 minutes < T , 6 minutes

60

6 minutes < T , 9 minutes

120

T> 9 minutes

180

Once deicing operation starts, it will not end for 60 seconds.


After deicing operation, compressor stops for 30 seconds and 4-way valve stays at cooling position for 10 seconds.

23
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Operation Details
Normal Deicing Time Diagram
a
Indoor
Heat
Exchanger
Temp.

39C
34C
30C

(TRS)
Outdoor
Heat
Exchanger
Temp.

(OPEN)
4C
(CLOSE)
3C

30'

60'

12' 10" 20"

max 12' 10" 20"

60'

Basic Time
30"

Td

30"

Compressor
4-way Valve
SLo Lo-

Indoor Fan

SLo Lo-

Outdoor Fan
Operation LED
<Description of operation>
ac
: Deicing operation judging condition established
cd
: Deicing operation (timer detected)
d e, l m : Time delay for 4-way valve
e f, m n : Time delay for Compressor
f g, n o : Hot start (no thermo OFF)
g h, o p : No thermo OFF (after finished hot start)
jl
: Deicing operation (TRS detected)

: Blinking
Operation
Stop

Overload Deicing Time Diagram


a

51C
Indoor
Heat
Exchanger
Temp.

49C
39C
34C
30C

(OPEN)
(TRS)
4C
Outdoor
(CLOSE)
Heat
3C
Exchanger
Temp.

60
Basic Time

min 10" 20"


1
max
12

60 max 12 10" 20"


Td

Compressor
4-way Valve
Indoor Fan

SLo Lo

Outdoor Fan
Operation LED

<Description of operation>
a d, k h : Overload Control
dg
: Overload Deicing (timer detected)
gh
: Hot Start (indoor fan OFF)
hi
: Hot Start (indoor fan SLo)
np
: Overload Control (TRS detected)

24
Downloaded from www.Manualslib.com manuals search engine

: Blinking
Operation
Stop

CS-A73KE

Operation Details
4) Automatic Mode Operation
a)

When the Automatic Mode Operation is selected, the indoor fan operates at Lo-- fan speed for 20 second to sense
intake air temperature and determine the 1st operation mode.

Standard for Determining Operation Mode


1st Judgement

Intake
Air
Temperature
b)

Cooling
23C

Soft Dry

20C

Heating

* Automatic Set Temperature


Refer c) as below.

Operation mode will be determine again after 1hour of operation, if the room temperature reaches to set
temperature and compressor off time is over 7 minutes 30 seconds continuously.
* The present operation mode will be continued, if the room temperature does not reach to set temperature
(Compressor keeps running) eventhough after 1 hour from automatic operation mode started.

For 2nd judgement onwards, indoor fan will operate for 25 seconds to sense the intake air temperature for
determining operation mode.
Standard for Determining Operation Mode
2nd Judgement onwards
Present
Mode

Judgement
Cooling
O
(Judgement :
23C & Above)

Next Mode
Soft Dry

Heating
O
(Judgement :
Below 23C)

Cooling

23C Cooling
Heating

Soft Dry

20C Soft Dry


Heating

Not Applicable

O
Judgement :
20C & Above)

O
Judgement :
Below 20C)

Heating

Cooling
25C Heating

O
(Judgement :
Above 25C)

Not Applicable

O
(Judgement :
25C & below)

Not Applicable

* Automatic Set Temperature


Refer c) as below.
c) Automatic Set Temperature
For each operation, set temperature will automatically set as shown below.
However it can be selected 2C higher or 2C lower from standard set temperature by pressing the "Room
Temperature Setting button"
Operation
Mode
Cooling
Soft Dry
Heating

,Hi
a
(+2C)
27C
24C
23C

a
(0C)
25C
22C
21C

25
Downloaded from www.Manualslib.com manuals search engine

a
9Lo
(-2C)
23C
20C
19C

CS-A73KE

Operation Details
5) Sleep Mode Auto Operation
Cooling or Soft Dry Operation
Approx. 0.5C increase

When you press the SLEEP Mode, the following movement will start
to avoid overcooling.

SETTING
TEMPERATURE

TEMP.

The fan speed refer to Indoor Fan Motor Control.


The setting temperature will be risen by 0.5C at the start of
operation and by 0.5C one hour later.
The operation will stop after 8 hours.
When using together with the Timer, the ON-Timer has priority.

Approx. 0.5C increase


1 hour

0 1 hour
Sleep Operation button is
pressed

Approx. 8 hours after


sleep shift operation
starts, stops automatically
TIME

Sleep shift operation


starts

Heating Operation

The fan speed refer to Indoor Fan Motor Control.


The setting temperature will be decrease by 2C at the start of
operation and by 3C one hour later.
The operation will stop after 8 hours.
When using together with the Timer, the ON-Timer has priority.

TEMP.
SETTING
TEMPERATURE

When you press the SLEEP Mode, the following movement will start
to avoid overheating.

Sleep shift operation starts

0 1 hour

Sleep shift operation starts

Approx. 2C decrease

1 hour

Approx. 8 hours
after sleep shift
operation starts,
stops
automatically

Approx. 3C decrease

TIME

6) Random Auto Restart Control


If there is a power failure, operation will be automatically restarted after 3 to 5 1/2 minutes when the power is resumed.
It will start with previous operation mode and airflow direction.
Restart time is decided randomly using 4 parameter:Intake air temperature, setting temperature, fan speed and Air Swing Blade position.
Random Auto Restart Control is not available when Timer or Sleep Mode is set.
This control can be omitted by open the circuit of J X 1. (Refer Circuit Diagram)

7) Delay ON Timer Control


When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time,
so that the room will reach nearly to the set temperature by the desired time.
For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
For Heating mode, the operation will start 30 minutes before the set time.
For Automatic mode, the indoor fan will operate at Lo-- speed for 20 seconds, 30 minutes before the set time to detect
the intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.

8) Remote Control Signal Receiving Sound


Peep sound (Long) will be heard when: Stopping the Air Conditioner using ON/OFF switch.
Stopping the Sleep Mode.
Stopping the Powerful Mode.
Stopping the Economy Mode.
Pep sound (Short) will be heard for others.
To switch off the peep sound
press the "Auto Operation Button" continuously for 10 seconds or more.
Repeat the above if you want to switch ON the beep sound or switch OFF the power switch at the indoor unit and
switch it ON again.
* However, if the "Auto Operation Button" have been pressed the Automatic cooling operation will be activated.
If you do not require this operation, you may change it by using the remote control.
26
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Operation Details
6) Indoor Fan Speed Control
Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is shifted automatically between Stop to SHi depend on
each operation as shown below.
Manual Fan Speed Control
Basic fan speed adjustment (3 setting, from Lo to Hi) can be carried out by using the Fan Speed
Selection button at the remote control.
Tap

Normal

COOLING
Powerful

Economy

SOFT
DRY

Normal
Powerful
Economy

Normal
HEATING
(A73K)
Powerful

Economy

Normal
HEATING
(93K &
A123K)
Powerful

Ecomony

SHi
Hi
Manual
Me
Lo
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Hi
Manual
Me
Lo
LoSLo
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Hi
Manual
Me
Lo
LoSLo
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift
Manual
Auto Fan Speed
Sleep Shift

Hi
O

Lo

RLo

Lo--

SLo

Stop

O
O

O
O

O
O
O

O
O
O

O
O
O

O
O

O
O
O
O
O
O

O
O
O

O
O

O
O

O
O

O
O

O
O

O
O

O
O

O
O

MODE JUDGEMENT

O
O
O
O
O

O
O

O
O
O
O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O

O
O
O
O
O

27
Downloaded from www.Manualslib.com manuals search engine

Me

O
O
O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O

CS-A73KE

Operation Details
* Lo-- :
* SLo :
* RLo :

Indoor Fan rotates at 6 seconds ON and 4 seconds OFF


Indoor Fan rotates at 4 second intervals at Low speed.
Random Low Speed.
Lo, RLo-, RLo--, Fan Speed is operates randomly.

Random Low Speed


Fan Speed
Time
Fan Motor

Lo
10"
ON

RLo4.5" 0.5" 4.5" 0.5"


ON OFF ON OFF

4"
ON

RLo-1"
4"
OFF ON

1"
OFF

10) Airflow Direction Control


a) Vertical Airflow Direction
Cooling and Soft Dry Mode.
Airflow Direction Manual-Control

Airflow Direction Auto-Control

36
140.5
Closing
position

Horizontal

Horizontal

Upper limit
Swing up
and down

Upper limit / 0
9
18
27
Lower limit for
Cooling and Soft Dry
Mode / 36

140.5
Closing
position

Lower limit for Cooling


and soft Dry Mode

The louver can be selected between 0 36 (as


shown above) when pressing Manual Airflow
Direction Selection Button.

The louver swings up and down as shown above.


The louver does not swing when the Indoor Fan
stops during operation.
b) Vertical Airflow Direction
Heating Mode
Airflow Direction Auto-Control

Airflow Direction Manual-Control


Horizontal

Horizontal
Upper limit

61
140.5
Closing
position

140.5
Closing
position

Lower limit
for Heating Mode / 61

The louver can be selected between 0 61 (as


shown above) when pressing Manual airflow Direction Selection Button.

When the intake air temp. reaches 38C, the louver


is changed from upper to lower limit. When the
intake air temp falls to 35C, the louver is changed
from lower to upper limit.
C)Horizontal Airflow Direction

The left and right airflow direction louvers can be adjusted manually.

28
Downloaded from www.Manualslib.com manuals search engine

Upper limit / 0
10
30
45
Lower limit
for Heating Mode / 61

CS-A73KE

Operation Details
11) Economy Mode Operation
Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner.
However consumer is advised to use Economy Mode operation after the room temperature reaches the desired
temperature.

a) Cooling and Soft Dry Mode

When the Economy Mode is set, the set temperature will be automatically increased 0.5C against the
present setting temperature. This operation automatically will be running under Random Low Fan Speed.

Vertical Airflow Direction :


In "manual" or "Auto" setting, the vane will automatically change to Auto Air Swing.

b) Heating Mode

When the Economy Mode is set, the temperature will be automatically decreased 0.5C against the present
setting temperature.

The Fan Speed will shift as shown below:

45

Me

39

Lo

34

Lo-

30

SLo

When the Auto Fan speed is selected, the fan speed will automatically
change from Slo to Me depending to the Indoor piping temperature.

When the manual Fan Speed is selected, the fan speed will automatically change from SLo to Lo, then follows set fan speed when the
Indoor piping temperature reaches 39C

38
30
28

Indoor
piping temp C

Set Fan Speed

15
OFF

Vertical Airflow Direction:


In "manual" or "Auto" setting, the vane will automatically change to Auto Air Swing.

c) Economy Mode will stop if:

Economy mode button is pressed again.


Stopped by ON/OFF switch.
Timer-off activates.
Powerful mode button is pressed.
Fan Speed control button is pressed.
Sleep mode button is pressed ON
Operating mode is changed.

29
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Operation Details
12) Powerful Mode Operation
Purpose of this operation is to be obtain the setting temperature quickly.

a) Cooling and Soft Dry Mode

When the Powerful Mode is set, the set temperature will be automatically decreased 3C against the
present setting temperature. This operation automatically will be running under Super High Fan Speed.

Vertical Airflow Direction :


In "manual" setting, the vane will automatically shift down 10 lower than previous setting.
In "Auto" setting, the vane will automatically swing up and down. However the upper and lower limit will
be shifted 10 downward.

b) Heating Mode

When the Powerful Mode is set, the set temperature will be automatically increased 3C against the present
setting temperature.

The Fan Speed will shift as shown below:

*48

Me

* 42

Lo

34

Lo-

30

SLo

When the Auto Fan speed is selected, the fan speed will automatically
change from SLo to Me depending to the Indoor piping temperature.

30

When the manual Fan Speed is selected, the fan speed will automatically change from SLo to Lo, then follows set fan speed when the
Indoor piping temperature reaches 42C.

28

Indoor
piping temp C

38

15
OFF

Set Fan Speed

* shows different temperature than normal heating. This higher


temperature is to provide warmer air.

Vertical Airflow Direction:


In "manual" setting, the vane will automatically shift down 5 lower than previous setting.
In "Auto" setting, the vane will automatically shift between upper and lower limit depending on the intake
air temperature as Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will
be shifted 5 downward.

c) Powerful mode will operate for 15 minutes only.


d) Powerful Mode will stop if:
Power mode button is pressed again.
Stopped by ON/OFF switch.
Timer-off activates.
Economy mode button is pressed.
Sleep mode button is presssed.
Operating mode is changed.

30
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Installation Information
Attached accessories
No.

Accessories part

Qty.

Installation plate

No.

1
7
Installation plate fixing screw

2
3

Qty.

Band

2
Vinyl tape

Vinyl tape

4
8

Remote control
TEM

POW

OFF
ERF

UL

Battery

4
5

Accessories part

Air purifying filter

/ON

1
Drain elbow

Accessories: Flaring piping kit


CZ-3F5, 7AEN
(CS/CU-A73KE, A93KE)
CZ-4F5, 7, 10AN
(CS/CU-A123KE)
SELECT THE BEST LOCATION
INDOOR UNIT

There should not be any heat source or steam near the unit.
There should not be any obstacles blocking the air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
Indoor unit of this room air conditioner shall be installed on the wall in a height of at least 2.3 m.
OUTDOOR UNIT

If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
There should not be any animal or plant which could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
Do not place any obstacles which may cause a short circuit of the discharged air.
If piping length is over the rated length, additional refrigerant should be added as shown in the table.
Piping size
MODEL

Max.
Common
Length Elevation
(m)

Max.
Piping Additional
Length Refrigerant
(g/m)
(m)

Gas

Liquid

A73KE/A93KE

3/8"

1/4"

7.5

10

20

A123KE

1/2"

1/4"

7.5

15

20

31
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Installation Information

Indoor / Outdoor unit installation diagram


Length of power supply cord
about 1.1 m
< <

Piping direction

about 1.8 m
<

Attention not to bend up drain hose


(Front side)

Right
Right
rear
Left
Right bottom rear

<

Left
Left bottom

Installation parts you must


purchase (*)
5 cm or
more

Installation plate 1
Sleeve (*)
Bushing-Sleeve (*)
Putty, (Gum Type Sealer) (*)

5 cm or
more

Air purifying filter 5

Bend the pipe as closely on the


wall as possible, but be careful
that it doesnt break.

(Left and right are identical)


Insulation of piping connection

Carry out insallation


after checking for gas
leaks.
After securing with
three of the vinyl
tape 7, wrap with
vinyl tape 8.

Vinyl tape (Wide) (*)


Apply after carrying out a
drainage test.
To carry out the drainage
test, remove into the air filters
and pour water into the heat
exchanger.

Vinyl tape
8
Vinyl tape 7

Saddle (*)

cm
10 ore
or m

Connecting cable
(3-CORE WIRE/1.5 mm2)
Locally approved cable.

cm
10 ore
or m

Additional drain hose (*)


10 cm
or more

cm
100 ore
or m

Saddle (*)

CU-A73KE
CU-A93KE

CU-A123KE

Connecting cable
(3-CORE WIRE/1.5 mm2)
Locally approved cable.
Additional drain hose (*)

1/4" Liquid side piping (*)

10 cm
or more

Gas side piping (*)


1/2"

1/4" Liquid side piping (*)


cm
100 ore
or m

Gas side piping (*)


3/8"
Vinyl tape (*)
(Narrow)

This illustration is for explanation purposes only.


The indoor unit will actually face a different way.

32
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

2-way 3-way Valve


2-way Valve (Liquid Side)

3-way Valve (Gas Side)

Valve cap
Flare nut

Hexagonal wrench (4 mm)


Open position
Closed position

To
piping
connection

Flare nut

Open position
Closed position

To
piping
connection

Pin
Service
port cap
To outdoor unit

To outdoor unit

Service port

Works

Shaft Position

Shaft Position

Service Port

Shipping

Close
(With valve cap)

Closed
(With valve cap)

Closed
(With cap)

Evacuation
Installation and
Re-installation

Closed
(Counter-Clockwise)

Closed
(Clockwise)

Open
(Push-pin)

Operation

Open
(With valve cap)

Open
(With valve cap)

Closed
(With cap)

Pumping down
(Transferring)

Closed
(Clockwise)

Open
(Counter-clockwise)

Open
(Connected manifold
gauge)

Evacuation
(Servicing)

Open

Open

Open
With vacuum pump

Gas charging
(Servicing)

Open

Open

Open
(With charging cylinder)

Pressure check
(Servicing)

Open

Open

Open
(Connected manifold
gauge)

Gas releasing
(Servicing)

Open

Open

Open
(Connected manifold
gauge)

33
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

1 Evacuation of Installation
WHEN INSTALLING AN AIR CONDITIONER, BE
SURE TO EVACUATE THE AIR INSIDE THE INDOOR
UNIT AND PIPES in the following procedure.

(Indoor unit)

If air remain in the indoor unit and refrigeration


pipes, it will affect the compressor, reduce to cooling capacity, and could lead to a malfunction.

(Liquid side)

(Outdoor unit)
2-way valve

Closed

(Gas side)

3-way valve
OPEN
Closed
Vacuum pump

Lo

Hi

CLOSE

Procedure:
(1) Connect a charging hose with a push pin to the
Low side of a charging set and the service port
of a 3-way valve.

Be sure to connect the end of the charging hose


with the push pin to the service port.

(5) Disconnect the charging hose from the vacuum


pump and from the service port of the
3-way valve.

(2) Connect the centre hose of the charging set


to a vacuum pump.

(7) Remove the valve caps of the 2-way valve


and the 3-way valve. Position both of the valves to
open using a hexagonal wrench (4 mm).

(3) Turn on the power switch of the vacuum pump and


make sure that the needle in the gauge moves
from 0 MPa (0 cmHg) to 0.1 MPa (76 cmHg). Then
evacuate the air for approximately ten minutes.
(4) Close the Low side valve of the charging set
and turn off the vacuum pump. Make sure that
the needle in the gauge does not move after
approximately five minutes.
BE SURE TO TAKE THIS PROCEDURE IN ORDER
TO AVOID GAS LEAKAGE.

(6) Tighten the service port cap at a torque of


18 Nm with a torque wrench.

(8) Mount the valve caps onto the 2-way and 3-way
valves.

Be sure to check for gas leakage.

Caution
If gauge needle does not move from 0 cmHg to
76 cmHg in step (3) above, take the following
measures:
If the leaks stop when the piping connections are
tightened further, continue working from step (3).
If the leaks do not stop when the connections are
retightened, repair the location of the leak.

34
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

2 Pumping down

(Indoor unit)

(Liquid side)

(Outdoor unit)
2-way valve

Closed

(Gas side)

3-way valve
CLOSE
Open
Refrigerant
Reclaiming
Equipment

Lo

Hi

CLOSE

Procedure:
(1) Confirm that both the 2-way and 3-way valves are
set to the opened position.

Remove the valve stem caps and confirm that the valve
stems are in the opened position.
Be sure to use a hexagonal wrench to operate the valve
stems.

(2) Operate the unit for 10 to 15 minutes.


(3) Stop operation and wait for 3 minutes, then connect the charge set to the service port of the 3-way
valve.

Connect the charge hose with the push pin to the Gas
service port.

(4) Air purging of the charge hose.

(6) Operate the air conditioner at the cooling cycle


and stop it when the gauge indicates 0 MPa
(0 kg/cm2G).
If the unit cannot be operated at the cooling
condition (weather is rather cool), short the
Pumping Down pins on the Main Control P.C.B.
(Simply press the pumping down button if it is
equipped.)
So that the unit can be operated.
(7) Immediately set the 3-way valve to the closed
position.

Open the low-pressure valve on the charge set slightly to


purge air from the charge hose.

(5) Set the 2-way valve to the closed position.

Do this quickly so that the gauge ends up indicating


0.1 MPa (1 kg/cm2G) to 0.3 MPa (3 kg/cm2G)

(8) Use refrigerant reclaiming equipment to


collect refrigerant from indoor unit and pipes.
(9) Disconnect the charge set, and mount the 2-way
and 3-way valves stem caps and the service port
caps.

Use a torque wrench to tighten the service port cap to a


torque of 18 Nm.
Be sure to check for gas leakage.

(10) Disconnect pipes from indoor unit and outdoor unit.


35
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

3 Evacuation of Re-installation
If air remain in the indoor unit and refrigeration
pipes, it will affect the compressor, reduce to cooling capacity, and could lead to a malfunction.

WHEN RE-INSTALLING AN AIR CONDITIONER, BE


SURE TO EVACUATE THE AIR INSIDE THE INDOOR
UNIT AND PIPES in the following procedure.

(Indoor unit)

(Liquid side)

(Outdoor unit)
2-way valve

Closed

(Gas side)

3-way valve
OPEN
Closed
Vacuum pump

Lo

Hi

CLOSE

Procedure:
(1) Connect a charging hose with a push pin to the
Low side of a charging set and the service port
of the 3-way valve.

Be sure to connect the end of the charging hose


with the push pin to the service port.
(2) Connect the center hose of the charging set
to a vacuum pump.
(3) Turn on the power switch of the vacuum pump and
make sure that the needle in the gauge moves
from 0 MPa (0 cmHg) to 0.1 MPa (76 cmHg).
Then evacuate the air for approximately ten
minutes.
(4) Close the Low side valve of the charging set
and turn off the vacuum pump. Make sure that
the needle in the gauge does not move after
approximately five minutes.
BE SURE TO TAKE THIS PROCEDURE IN ORDER
TO AVOID GAS LEAKAGE.
(5) Disconnect the charging hose from the vacuum
pump .
(6) Charge the pipes and indoor unit with gas refrigerant from 3-way valve service port, and then discharge the refrigerant until low side (gas side)
gauge needle indicates 0.3 MPa (3 kg/cm2)

36
Downloaded from www.Manualslib.com manuals search engine

(7) Tighten the service port cap at a torque of 18Nm


with a torque wrench.
(8) Remove the valve caps of the 2-way valve and
the 3-way valve. Position both of the valves to
"open" using a hexagonal wrench (4 mm).
(9) Mount valve caps onto the 2-way and 3-way
valves.
BE SURE TO USE REFRIGERANT RECLAIMING EQUIPMENT WHILE DISCHARGING THE
REFRIGERANT.
Purge the air from charge sets centre hose.
Be sure to check for gas leakage.

Caution
If gauge needle does not move from 0 MPa
(0 cmHg) to 0.1 MPa (76 cmHg) in step (3)
above, take the following measures:
If the leaks stop when the piping connections are
tightened further, continue working from step (3).
If the leaks do not stop when the connections are
retightened, repair the location of the leak.

CS-A73KE

4 Balance refrigerant of the 2-way, 3-way valves


(Lack of refrigerant in the refrigeration cycle)

(Indoor unit)

(Liquid side)

(Outdoor unit)
2-way valve

Open

(Gas side)

3-way valve
OPEN

Open
Lo

Refrigerant
Reclaiming
Equipment

Hi

CLOSE

Procedure:
(1) Confirm that both the 2-way and 3-way valves are
set to the open position.
(2) Connect the charge set to the 3-way valves
service port.

Leave the valve on the charge set closed.


Connect the charge hose with the push-pin to the
service port.

(3) Connect the charge sets centre hose to refrigerant reclaiming equipment.

Purge the air from charge hose.

(4) Open the valve (Low side) on the charge set


and discharge the refrigerant until the gauge
indicates 0.05 MPa (0.5 kg/cm2G) to 0.1 MPa
(1 kg/cm2G).

If there is no air in the refrigeration cycle (the pressure


when the air conditioner is not running is higher than
0.1 MPa (1 kg/cm2G), discharge the refrigerant until
the gauge indicates 0.05 MPa (0.5 kg/cm2G) to 0.1
MPa (1 kg/cm2G). If this is the case, it will not be
necessary to apply a evacuation.
Discharge the refrigerant gradually; if it is discharged
too suddenly, the refrigeration oil will also be discharged.

(5) Turn on refrigerant reclaiming equipment .


37
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

5 Evacuation
(No refrigerant in the refrigeration cycle)

(Indoor unit)

(Liquid side)

(Outdoor unit)
2-way valve

Open

(Gas side)

3-way valve
OPEN
Open
Vacuum pump

Lo

Hi

CLOSE

Procedure:
(1) Connect the vacuum pump to the charge sets
centre hose.
(2) Evacuation for approximately one hour.

Confirm that the gauge needle has moved toward


0.1 MPa (76 cmHg) [vacuum of 4 mmHg or less.]

(3) Close the valve (Low side ) on the charge set, turn
off the vacuum pump, and confirm that the gauge
needle does not move (approximately 5 minutes
after turning off the vacuum pump).
(4) Disconnect the charge hose from the vacuum
pump.

Vacuum pump oil


If the vacuum pump oil becomes dirty or depleted,
replenish as needed.

38
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

6 Gas charging
(After Evacuation)

(Indoor unit)

(Liquid side)

(Outdoor unit)
2-way valve

Open

(Gas side)

Check valve

3-way valve
Open
Lo

Charging
cylinder
OPEN

Hi

CLOSE

Procedure:
(1) Connect the charge hose to the charging cylinder.

This is different from previous procedures. Because


you are charging with liquid refrigerant from the gas
side, absolutely do not attempt to charge with large
amount of liquid refrigerant while operating the air
conditioner.

Connect the charge hose which you disconnected from


the vacuum pump to the valve at the bottom of the
cylinder.

(2) Purge the air from the charge hose.

Open the valve at the bottom of the cylinder and press the
check valve on the charge set to purge the air (be careful
of the liquid refrigerant).

(4) Immediately disconnect the charge hose from the


3-way valves service port.
- Stopping partway will allow the refrigerant to be discharged.
- If the system has been charged with liquid refrigerant
while operating the air conditioner, turn off the air conditioner before disconnecting the hose.

(3) Open the valve (Low side) on the charge set and
charge the system with liquid refrigerant.

If the system cannot be charged with the specified


amount of refrigerant, it can be charged with a little at
a time (approximately 150 g each time) while operating
the air conditioner in the cooling cycle; however, one
time is not sufficient, wait approximately 1 minute and
then repeat the procedure. (pumping down-pin)

(5) Mount the valve stem caps and the service port
cap.

39
Downloaded from www.Manualslib.com manuals search engine

Use torque wrench to tighten the service port cap to a


torque of 18 Nm.
Be sure to check for gas leakage.

CS-A73KE

Servicing Information
Tabs

Release hooks

Tab

Inspection points for the Indoor Electronic Controller


Tabs

Remove the 2 caps and 2 screws at the bottom


of the front grille. (Fig. 1)

Remove the front grille by releasing the 2 hooks


at the top of the front grille. (Fig. 1)

Remove the control board cover by releasing


the 2 tabs at left, 1 tab on top and 2 more tabs at
right side of the control board cover. (Fig. 1)

1. The Electronic Controller, a signal Receiver and an


Indicator (Fig. 2) can be seen by the below steps:

Control Board
Cover

Remove 2 caps and 2 screws

Fig. 1

Electronic Controller
Intake Air
Sensor

CN-C (GRN)
Hook

2. To remove the Electronic Controller, release the


hook that holding the electronic controller. (Fig. 2)

CN-FM
(GRN)
Earth Wire
Screw

Indoor Fan Motor removal procedure :1. Remove the control board by:-

Piping
Sensor

Releasing CN-C (GRN) connector


Releasing CN-FM (GRN) connector
Releasing CN-STM connector
Remove the earth wire screw
Release the intake air sensor
Release the piping sensor

Unhook and release the terminal board.(Fig. 3)

Remove the right and left screws.(Fig. 3)

(Fig. 2)
Signal
Receiver

Indicator

Fig. 2

Terminal Board
(Unhook)

Left hook
(press down)

Then remove the control board by pressing


down the hook at the left and press up the right
hook. (Fig. 3)

Screw
(remove)

CN-STM

right hook
(press up)

Screw
(remove)

2. Remove the Fan Motor by :

Release the fan motor leadwire by pressing the


hook at the center of the connector. (Fig. 4)

Then remove the particular piece that holding


the fan motor by pressing the tab. (Fig. 4)

Remove the discharge grille and then the drain


hose. (Fig. 4)

Fig. 3

Fan motor connector

Particular
piece

Tab

Fan motor
Discharge
grille

40
Downloaded from www.Manualslib.com manuals search engine

Fig. 4

CS-A73KE

Servicing Information

Finally remove the fan motor by removing the


screw. (Fig. 5)

REMINDER - To reinstall the fan motor, adjust


the connector of the fan motor as Figure 5.

To install back the


Fan motor,
Please adjust the
connector location.

Screw

Fan motor

Fig. 5

Cross Flow Fan Removal Procedure.


1. Remove the control board and the fan motor by
referring to the "Indoor Fan Motor Removal
Procedure".

Evaporator screw

2. Remove the evaporator screw (Fig. 6)

Fig. 6

3. Press the particular piece to loosen the evaporator.


(Fig. 7)

Evaporator

4. Remove the bearing. (Fig. 7)


5. Push up the evaporator and take out the cross flow
fan. (Fig. 7)

Push up
evaporator

Bearing

cross flow fan

Press the
particular
piece

Fig. 7
41
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Servicing Information
Remote Control Reset

Reset terminal

When the batteries are inserted for the first time, or


the batteries are replaced, all the indications will
blink and the remote control might not work.
If this happens, remove the back cover of the remote
control and you will find a resetting terminal, and by
shorting it with a minus screwdriver, it will return to
normal.

RES

ET

Changing the wireless remote control transmission code


When two indoor units are installed in the same
room, in order to prevent operating errors caused by
using two remote controls, set up the remote control [B
A] switch (SW1).
The unit is set to A when it is shipped.

Remote Control

SW1

Remote Controller

Switch

By adding a jumper wire to the remote control side and a carbon resistor (1/4 W, 10 k) to the indoor printed
circuit board, it is possible to select from 4 types of transmission codes including the condition at time of
delivery condition (1).
Remote control

Indoor printed circuit board


Note

Switch SW B A

JB

Switch SW1

RX1
At product delivery

Jumper wire

10k

Jumper wire

10k

42
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Troubleshooting Guide
Refrigeration cycle system
Normal Pressure and Outlet Air Temperature (Standard)

In order to diagnose malfunctions, make sure that


there are no electrical problems before inspecting the refrigeration cycle. Such problems include
insufficient insulation, problem with the power source,
malfunction of a compressor and a fan.
The normal outlet air temperature and pressure
of the refrigeration cycle depends on various conditions, the standard values for them are shown in the
table to the right.

Gas pressure
MPa
(kg/cm2G)

Outlet air
temperature
(C)

Cooling mode

0.4 ~ 0.6 (4 ~ 6)

12 ~ 16

Heating Mode

1.5 ~ 2.1 (15 ~ 21)

36 ~ 45

Condition: Indoor fan speed; High


Outdoor temperature 35C at the cooling mode
and 7C at the heating mode
Difference in the intake
and outlet
air temperatures

Normal

More than 8C
(15 minutes after an
operation is started.)
at the cooling mode
More than 14C
(15 minutes after an
operation is started.)
at the heating mode

Measuring the air temperature


difference

Less than 8C at the cooling mode


Less than 14C at the heating mode

Value of electric
current during operation

Higher than specified

Dusty condenser
preventing heat radiation

Measuring electric current


during operation

Excessive amount
of refrigerant

Lower than specified

Gas side
pressure

Cooling Mode

High

Inefficient compressor
Low

Insufficient refrigerant
Low

Clogged strainer or
capillary tube

Low

Inefficient compressor

Heating Mode
Low

Insufficient refrigerant
Low

Clogged strainer or
capillary tube

43
Downloaded from www.Manualslib.com manuals search engine

Measuring gas side pressure

CS-A73KE

Troubleshooting Guide
1. Relationship between the condition of the air conditioner and pressure and
electric current
Cooling Mode

Heating Mode

Condition of the air


conditioner

Low Pressure

High Pressure

Electric
current during
operation

Low Pressure

High Pressure

Electric
current during
operation

Insufficient refrigerant
(gas leakage)

Clogged capillary tube


or Strainer

Short circuit in the


indoor unit

Heat radiation deficiency of the outdoor


unit

Inefficient
compression

Carry out the measurements of pressure, electric current, and temperature fifteen minutes after an operation is
started.

2. Diagnosis methods of a malfunction of a compressor and a 4-way valve


Nature of fault

Insufficient compressing of a
compressor

Symptom

Electric current during operation becomes approximately 20% lower than the
normal value.

The discharge tube of the compressor becomes abnormally hot (normally 70 to 90C).

The difference between high pressure and low pressure becomes


almost zero.

Electric current reaches a high level abnormally, and the value exceeds the
limit of an ammeter. In some cases, a breaker turns off.

The compressor is a humming sound.

Electric current during operation becomes approximately 80% lower than


the normal value.

The temperature difference between from the discharge tube to the 4-way valve
and from suction tube to the 4-way valve becomes almost zero.

Locked compressor

Inefficient switches of the 4-way valve

44
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Technical Data
L Thermostat characteristics
CS-A73KE / CS-A93KE / CS-A123KE
Soft Dry

Cooling

(C)
34

(C)
34

32

32

30

30
COMP. ON

COMP. OFF = Set Temperature

Diff. 1.5C

22

24

18

18
20

22

24

26

16

Thermostat Setting (Remote Control)

18

20

(C)
34

30

COMP. OFF = SET TEMPERATURE

28

COMP. ON

/
/

diff. 2.0C

24
/

Intake Air Temperature

32

22
20
18
16
16

18

20

22

Diff. 1.0C

22

24

26

28

Thermostat Setting (Remote Control)

Heating

26

Soft Dry OFF, Soft Dry ON


Diff. 1.5C

16

30 (C)

28

/
/

22
20

16 18

Cooling OFF = Set Temperature,

26

20

16

24

24

26

28

30 (C)

Thermostat setting (remote control)

45
Downloaded from www.Manualslib.com manuals search engine

Cooling ON

28
Intake Air Temperature

26

Intake Air Temperature

28

30

CS-A73KE

Technical Data
L Operation characteristics
CS-A73KE / CU-A73KE
Piping Length Characteristic (Cooling)

Cooling Characteristic

34

36

38

40

42

10

PIPING LENGTH (m)


[Condition] Room temperature: 27/19C
Outdoor temperature: 35/24C
Cooling operation: At High fan

[Condition] Room temperature: 27/19C


Cooling operation: at High fan
Piping length: 7.5m

Piping Length Characteristic (Heating)

Heating Characteristic
220V
230V

-2

O: Outlet

2.6
2.4
2.2
2.0
1.8

1.38
1.36
1.34
1.32
1.30

5
4
3
2
1

10

PIPING LENGTH (m)


[Condition] Room temperature: 20C
Outdoor temperature: 7/6C
Heating operation: At High fan

OUTDOOR AIR TEMPERATURE (C)


[Condition] Room temperature: 20C
Heating operation: at High fan
Piping length: 7.5m

46
Downloaded from www.Manualslib.com manuals search engine

34.0
33.8
33.6
33.4
33.2
33.0

LP:

Q:

4
3
2
1

I:

Current (A)

I:

1.3
1.2
1.1
1.0
0.9

Heating Capacity (kW)

Air Temperature (C)

1.4

Current (A)

O: Outlet

Gas Side Pipng Pressure (MPa)

2.4
2.2
2.0
1.8
1.6

LP:

Heating Capacity (kW)

Q:

220V
230V

36
34
32
30
28
26

-4

- Air Temperature (C)

O: Outlet
1

44

Gas Side Piping Pressure (MPa)

5
4
3
2

OUTDOOR AIR TEMPERATURE (C)

0.65
0.60
0.55
0.50
0.45

LP:

Q:

Cooling Capacity (kW)


-

2.6
2.4
2.2
2.0
1.8

10

- Air Temperature (C)

32

15
14
13
12
11

Gas Side Piping Pressure (MPa)

30

Current (A)

5
4
3
2

LP:

Current (A)

I:

0.70
0.65
0.60
0.55
0.50

I:

O: Outlet

2.4
2.2
2.0
1.8

- Air Temperature (C)

16

12
2.6

17
16
15
14
13

Gas Side Pipng Pressure (MPa)

Q:

Cooling Capacity (kW)


-

220V
230V

220V
230V

CS-A73KE

Technical Data
L Operation characteristics
CS-A93KE / CU-A93KE
Cooling Characteristic

Piping Length Characteristic (Cooling)

34

36

38

40

42

O: Outlet
5

10

PIPING LENGTH (m)


[Condition] Room temperature: 27/19C
Outdoor temperature: 35/24C
Cooling operation: At High fan

OUTDOOR AIR TEMPERATURE (C)

Heating Characteristic

Piping Length Characteristic (Heating)


220V
230V

-4

-2

10

O: Outlet

3.6
3.5
3.4
3.3
3.2

1.50
1.49
1.48
1.47
1.46

5
4
3
2

(220V and 230V)

OUTDOOR AIR TEMPERATURE (C)

PIPING LENGTH (m)


[Condition] Room temperature: 20C
Outdoor temperature: 7/6C
Heating operation: At High fan

[Condition] Room temperature: 20C


Heating operation: at High fan
Piping length: 7.5m

47
Downloaded from www.Manualslib.com manuals search engine

37.0
36.8
36.6
36.4
36.2
36.0

LP:

Q:

(220V and 230V)

I:

Current (A)

I:

1.4
1.2
1.0
0.8

Heating Capacity (kW)

Air Temperature (C)

1.8
1.6

Current (A)

O: Outlet

2.8
2.6
2.4
2.2

Gas Side Pipng Pressure (MPa)

3.4
3.2
3.0

LP:

Q:

Heating Capacity (kW)

220V
230V
38
36
34
32
30
28
26

4
3
2
1

Gas Side Piping Pressure (MPa)

LP:
1

[Condition] Room temperature: 27/19C


Cooling operation: at High fan
Piping length: 7.5m

(220V and 230V)

5
4
3
2

44

0.65
0.60
0.55
0.50
0.45

- Air Temperature (C)

Q:

2.8
2.7
2.6
2.5
2.4

10

- Air Temperature (C)

32

16
15
14
13
12
11

Gas Side Piping Pressure (MPa)

30

Current (A)

(220V and 230V)

5
4
3
2

I:

0.60
0.55
0.50
0.45
0.40

Cooling Capacity (kW)

O: Outlet

2.9
2.8
2.7
2.6
2.5

- Air Temperature (C)

12

Gas Side Pipng Pressure (MPa)

17
16
15
14
13

LP:

Q:

Cooling Capacity (kW)


Current (A)

I:

220V
230V

220V
230V

CS-A73KE

Technical Data
L Operation characteristics
CS-A123KE / CU-A123KE
Cooling Characteristic

Piping Length Characteristic (Cooling)

38

40

42

10

12

14

Q:
(220V and 230V)

4.6
4.4
4.2
4.0
3.8

Air Temperature (C)

1.6
1.5
1.4
1.3
1.2

10

6
5
4
3

(220V and 230V)

OUTDOOR AIR TEMPERATURE (C)

10

12

14

PIPING LENGTH (m)

[Condition] Room temperature: 20C


Heating operation: at High fan
Piping length: 7.5m

[Condition] Room temperature: 20C


Otudoor temperature: 7/6c
Heating operation: at High fan

48
Downloaded from www.Manualslib.com manuals search engine

44
43
42
41
40
39

1.7

I:

Current (A)

I:

1.6
1.4
1.2
1.0
0.8

Heating Capacity (kW)

Air Temperature (C)

1.8

Current (A)

O: Outlet

3.6
3.4
3.2
3.0

Gas Side Pipng Pressure (MPa)

4.6
4.4
4.2
4.0
3.8

LP:

Heating Capacity (kW)

Q:

220V
230V
44
42
40
38
36
34
32

-2

O: Outlet

Piping Length Characteristic (Heating)


220V
230V

-4

Gas Side Pipng Pressure (MPa)

[Condition] Room temperature: 27/19C


Outdoor temperature: 35/24C
Cooling operation: at High fan

Heating Characteristic

6
5
4
3

16

PIPING LENGTH (m)

[Condition] Room temperature: 27/19C


Cooling operation: at High fan
Piping length: 7.5m

LP:

Q:

44

OUTDOOR AIR TEMPERATURE (C)

Air Temperature (C)

36

(220V and 230V)

O: Outlet

34

6
5
4
3

Gas Side Pipng Pressure (MPa)

32

3.8
3.6
3.4
3.2
3.0

LP:

30

16
15
14
13
12
11

0.8
0.7
0.6
0.5
0.4
0.3
Current (A)

(220V and 230V)

5
4
3
2

LP:

Current (A)

I:

0.65
0.60
0.55
0.50
0.45

I:

4.0
3.8
3.6
3.4
3.2

Cooling Capacity (kW)

O: Outlet

12

- Air Temperature (C)

17
16
15
14
13

Gas Side Pipng Pressure (MPa)

Q:

Cooling Capacity (kW)


-

220V
230V

220V
230V

16

CS-A73KE

Exploded View
CS-A73KE / CS-A93KE / CS-A123KE

6
5
"
7
#

8
7
3

4
\
:

!
[

<

/
>

@
?

$
%

_
& (
,

&

+
~

(
)

2
{

V
1
8

2
0

]
^

9
9

(Note) : The above exploded view is for the purpose of parts disassembly and replacement.
The non-numbered parts are not kept as standard service parts.
49
Downloaded from www.Manualslib.com manuals search engine

CS-C73KE

CS-A73KE

Replacement Parts List


<Model: CS-A73KE / CS-A93KE / CS-A123KE>
NO.

DESCRIPTION & NAME

QTY
1

CS-A73KE

CHASSY COMPLETE

CWD50C338

PARTICULAR PIECE

CWD931019

FAN MOTOR

CWA92288

LEAD WIRE FAN MOTOR

CWA67C2097

CROSS FLOW FAN

CWH02C060

BEARING

CWH64K007

SCREW CROSS FLOW FAN

CWH4580304

EVAPORATOR & TUBE ASSY COMPLETE

CWB30C259

INTAKE AIR SENSOR HOLDER

CWH32142

10

ANTI VIBRATION BUSHING

CWH50211

11

FLARE NUT (1/4)

CWH6002140

12

FLARE NUT (1/2) OR (3/8)

CWT25005 (3/8)

13

DISCHARGE GRILLE COMPLETE

CWE20C610

CS-A93KE

CS-A123KE

@
@

@
@

CWA92286

CWA92290

@
@
@
@
@
@
@
@
@

@
@
@
@

CWE20C624

14

VERTICAL VANE WITH TAB

CWE24458

15

VERTICAL VANE

10

CWE24457

16

CONNECTING BAR

CWE26194

@
@
@

17

AIR SWING MOTOR

CWA98260

CWA98C033

18

LEAD WIRE AIR SWING MOTOR

CWA67C2106

19

CAP FOR DRAIN TRAY

CWH52C003

20

HORIZONTAL VANE

CWE24462
CWH10965

21

CONTROL BOARD

22

POWER SUPPLY CORD

CWA20C751

23

SLIDE SWITCH

CWA04088

@
@
@
@
@
@

24

ELECTRONIC CONTROLLER

CWA741388

CWA741491

25

RECEIVER

CWA74919

26

INDICATOR COMPLETE

CWA741376`

27

LEAD WIRE INDICATOR

CWA67C2105

28

TERMINAL BOARD

CWA28C575

29

INDICATOR HOLDER

CWD931018

30

SENSOR COMPLETE

CWA50C608

31

CONTROL BOARD FRONT COVER

CWH13456

32

CONTROL BOARD TOP COVER

CWH13457

33

REMOTE CONTROL COMPLETE

CWA75C723

34

REMOTE CONTROL HOLDER*

CWH36161

35

FRONT GRILLE COMPLETE

@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@

CWE11C978

36

INTAKE GRILLE COMPLETE

CWE22C333

37

DECORATION BASE COMPLETE

CWE35C023

38

TAB

CWD931020

39

AIR FILTER

CWD00240

40

GRILLE DOOR

CWE14236

41

SCREW FOR FRONT GRILLE

XTN4+16C

42

CAP FOR FRONT GRILLE

CWH52267

43

DRAIN HOSE

CWH5880580

44

OPERATING INSTRUCTIONS
(ENG/SPA/GER/FRA/NED/ITA)

CWF561595

44a

OPERATING INSTRUCTIONS (POR/GRK)

CWF56195A

44b

OPERATING INSTRUCTIONS (RUSSIAN)

CWF56195B

45

INSTALLATION INSTRUCTIONS

CWF61674

46

INSTALLATION PLATE

CWH36157

47

BAG COMPLETE - INSTALLATION SCREW

CWH82C144

48

AIR PURIFYING FILTER COMPLETE

49

(Note)

AIR PURIFYING FILTER

CWD00C111

CWD00220

All parts are supplied from MACC, Malaysia (Vendor Code: 086).
_ marked parts are recommended to be kept in stock.
* Is an optional parts
50

Downloaded from www.Manualslib.com manuals search engine

@
@
@
@
@
@
@

REMARKS

CWB30C260

@
@
@
CWT25007 (1/2)

@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
CWA28C576

@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@

_
_
_
_
_
_

@
@
CWF61685

@
@
@
@

CS-A73KE

Exploded View
CU-A73KE / CU-A93KE
?

>

=
_

<

"

2
+

(
)

&

:
6

/
.
-

$
~

1
8

,
!
9
(Note) : The above exploded view is for the purpose of parts disassembly and replacement.
The non-numbered parts are not kept as standard service parts.
51
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Replacement Parts List


<Model: CU-A73KE / CU-A93KE>
NO.

DESCRIPTION & NAME

QTY

CS-A73KE

CS-A93KE

REMARKS

CHASSY ASSY

CWD50K438F

FAN MOTOR BRACKET

CWD54113

SCREW FAN MOTOR BRACKET

CWH4580399

FAN MOTOR

CWA95245

SCREW FAN MOTOR MOUNT

CWH55027

PROPELLER FAN

CWH00K052

NUT PROPELLER FAN

CWH56032

COMPRESSOR

2RS127D3CA04

ANTI VIBRATION BUSHING

CWH50077

10

NUT COMPRESSOR MOUNT

CWH56000

11

CONDENSER

CWB32C043

12

HOLDER COUPLING ASSY

CWH35K017A

13

4-WAY VALVE

CWB00002

14

3-WAY VALVE

CWB01479

15

2-WAY VALVE

CWB02307

16

STRAINER

CWB11025

17

TUBE ASSY (CHECK VALVE/CAPILARY)

CWT01C638

CWT01C639

18

V COIL COMPLETE

CWA43C424

SOUND PROOF BOARD

CWH15266

20

SOUND PROOF MATERIAL


(FOR COMPRESSOR)

CWG30786

@
@
@

19

21

OVERLOAD PROTECTOR

CWA67C2073

CWA67C2074

22

HOLDER O.L.P

CWH7041200

23

TERMINAL COVER

CWH17006

24

NUT TERMINAL COVER

CWH7080300

25

CONTROL BOARD

CWH10881

26

TERMINAL BOARD ASSY

CWA28C500

27

ELECTROLYTIC CAPACITOR

CWA32C045

28

ELECTROLYTIC CAPACITOR

CWA32C067

@
@
@
@
@
@
@

29

CAPACITOR-COMPRESSOR

CWA31653
(15F,440V)

CWA31646
(25F,370V)

30

HOLDER CAPACITOR

CWH30057

31

CAPACITOR FAN MOTOR

CWA31342
(1.2F,400V)

@
@

32

ELECTROMAGNETIC SWITCH

CWA00059

33

TERMINAL BOARD ASS'Y

CWA4711012

34

TEMPERATURE RELAY

CWA14C000

35

CABINET ASSY

CWE00K330A

36

CABINET FRONT PLATE

CWE06C117A

37

CONTROL BOARD COVER

CWH13C286

38

HANDLE

CWE16037C

(Note)

CWD50K456D

@
@
@
@
@
@
2PS174D3AA02

All parts are supplied from MACC, Malaysia (Vendor Code: 086).
_ marked parts are recommended to be kept in stock.

52
Downloaded from www.Manualslib.com manuals search engine

@
@
@
@
@
@
@
@

@
@
@
@
@
@
@

_
_
_

_
_
_

_
_
_

CS-A73KE

Exploded View
CU-A123KE
0
@
3
[

>
|

<

1
9

&
3
{

"
)

/
.
-

!
(

,
6

1
#

$
8
7

(Note) : The above exploded view is for the purpose of parts disassembly and replacement.
The non-numbered parts are not kept as standard service parts.
53
Downloaded from www.Manualslib.com manuals search engine

CS-A73KE

Replacement Parts List


<Model: CU-A123KE>
NO.
1
2
3
4
5

DESCRIPTION & NAME


CHASSY ASSY
FAN MOTOR BRACKET
SCREW FAN MOTOR BRACKET
FAN MOTOR
SCREW FAN MOTOR MOUNT

QTY
1
1
6
1
4

CU-A123KE
CWD50K659A
CWD54254
CWH55413
CWA95381
CWH55252

REMARKS

6
7
8
9
10
11
12
13
14

COMPRESSOR
ANTI VIBRATION BUSHING
NUT COMPRESSOR MOUNT
CONDENSER
4-WAY VALVE
TUBE ASS'Y (CHECK VALVE / CAPILLARY)
HOLDER COUPLING ASSY
3-WAY VALVE
2-WAY VALVE

1
3
3
1
1
1
1
1
1

2KS224D5CA02
CWH50055
CWH4582065
CWB32C336
CWB00003
CWT01C652
CWH35K063
CWB01480
CWB02308

15
16
17
18
19

STRAINER
V COIL COMPLETE
SOUND PROOF BOARD
SOUND PROOF MATERIAL
WIRE NET

1
1
1
1
1

CWB11025
CWA43C689
CWH15288
CWG30911
CWD04197A

20
21

AIR GUIDER PROPELLER FAN


OVERLOAD PROTECTOR

1
1

CWD31138
CWA12360

22
23
24
25
26

HOLDER O.L.P.
TERMINAL COVER
NUT TERMINAL COVER
TEMPERATURE RELAY
CONTROL BOARD

1
1
1
1
1

CWH7041200
CWH17006
CWH7080300
CWA14C000
CWH10972

27
28
29
30

TERMINAL BOARD ASSY


ELECTROLYTIC CAPACITOR
TERMINAL BOARD ASSY
CAPACITOR-COMPRESSOR

1
1
1
1

CWA28C583
CWA32C045
CWA4711012
CWA31647

31
32

HOLDER CAPACITOR
CAPACITOR FAN MOTOR

1
1

33
34
35
36
37
38
39
40
41

ELECTROMAGNETIC SWITCH
ELECTROLYTIC CAPACITOR
PROPELLER FAN ASSY
NUT-PROPELLER FAN
CABINET SIDE PLATE (RIGHT)
CABINET SIDE PLATE (LEFT)
CABINET FRONT PLATE
HANDLE
CONTROL BOARD COVER

2
1
1
1
1
1
1
1
1

(30F, 370 V)
CWH30057
CWA31227
(1.5F, 400 V)
CWA00059
CWA32C067
CWH00K087
CWH56053
CWE04217A
CWE04220A
CWE06K104A
CWE16037C
CWH13461

42
43

PLATE FOR CONTROL BOARD COVER


CABINET TOP PLATE

1
1

CWD91258
CWE03K035A

(Note)

All parts are supplied from MACC, Malaysia (Vendor Code: 086).
_ marked parts are recommended to be kept in stock.

54
Downloaded from www.Manualslib.com manuals search engine

_
_
_

_
_

_
_
_

CS-A73KE

Electronic Parts List


<Electronic Controller Part No. : CWA741388, CWA741491>
SYMBOL
BZ1
CT1
D1
D2

DESCRIPTION & NAME


SOUND GENERATOR
TRANSFORMER
DIODE
DIODE

A48040
A40322
A541SR1544
A54RB501V40

DIODE
DOIDE
FUSE
FUSE HOLDER
INTERGRATED CIRCUIT
INTERGRATED CIRCUIT
INTERGRATED CIRCUIT
INTERGRATED CIRCUIT
INTERGRATED CIRCUIT

A541SS355T
A54CS1VB20E
XBA2C20TR0
XCSCW032
A52D0022G503
A52BR9020F
A52A2003GR2
A52C040
A52C114

Q1
Q2, Q3
Q4
Q5 Q8
RYHOT

TRANSISTOR
TRANSISTOR
TRANSISTOR
TRANSISTOR
ELECTRO MAGNETIC RELAY

A55DC114EKTX
A55C2412KTX
A55D1484K
A55DC143XKTX
A00161

RYPWR
RYSHi , RYHi , RYM

ELECTRO MAGNETIC RELAY


ELECTRO MAGNETIC RELAY

A00106
A00160

TYRISTOR
SLIDE SWITCH
PUSH SWITCH
TRANSFORMER
RESONATOR
DIODE

A56W2DEH1-5
A04085
A01059
A40366
A45CST4.09MG
A54D7.5MT1B

DIODE
SH CAPACITOR
TEMPERATURE FUSE
CURRENT TRANSFORMER
SURGE ABSORBER

ERZVEAV511
A31698
A16C204
A28069T
A59014

D3
DB1
FUSE
FUSE HOLDER
IC1
IC2
IC3
IC4
IC5

SSR1 , SSR2
SW1
SW2 , SW3
T1
X1
ZD1
ZNR1 , ZNR2 , ZNR3
CFM
TEMP FUSE
HOT (RED)
CR1, CR2, CR3, CR4, CR5

(Note)

PART NO.

All parts are supplied from MACC, Malaysia (Vendor Code: 086).

MACC

55
Downloaded from www.Manualslib.com manuals search engine

Printed in Malaysia
P990103000CT

CS-A73K/A93K/A123K

CS-A73K/A93K/A123K

CS-A73K/A93K/A123K

CS-A73K/A93K/A123K

ELECTRONIC CIRCUIT DIAGRAM

CS-A73KE / CU-A73KE
CS-A93KE / CU-A93KE
CS-A123KE / CU-A123KE

Fig. 1

Fig. 2

Senser (Thermistor)
Characteristics

Intake Air/
Pipe Temp. Data

70
60

MAIN

4.7k

4.7k

4.7k

b
4.7k

P74

P73

P70

P02
INTP1

REMOTE CONTROL
COMMAND INPUT

Vss0

X2

45

T1

10

44

X1
8MHz (27pF X 2)

41

24

INTAKE
AIR TEMP

27

28

29

31

10

9
g
f

12

13

BZ1

14

BZ

15

1
2
3
4
5
AIR SWING
MOTOR

REGULATOR

12

5V

I
+

C2
470
25V
(NHG)

R23
1k

16

BLACK
BLACK

RY-H
+

C3
100
16V
(NHG)

MAGNETIC
RELAY B

IC5
A52A2003GR2

20

30

40

R2
10k

C5
0.022

120

CR1
0.022

120

CR2
0.022

120

CR3
0.022

120

CR4
0.022

BLUE

CS/CU-A73K ( CWA12345 )

RED

BLUE

CAPACITOR
4.7k

10k
e

R4
100k

C5
1
50V

R5
10k

Q2
2SC2412KTX

R3
1.0k

C19
0.01

ZD1
7.5EL1

Q3
2SC2412KTX

RESET SIGNAL
GENERATION

RESET SIGNAL
c GENERATION

BLUE
BLUE

YELLOW

R44
10k

R7
6.2k

50
30
20
10
7
5
3

20

R6
6.2k

BLUE

C7
0.01
1 2 3

40

60

80

100

120

140

RED

Ambient Temperature (C)

TRADE MARK

C-FM
1.5
400V AC

COMPRESSOR
TERMINAL
1

CN-FM
(VH-1)
(GREEN)

IC2
A52BR9020F

STEPPING MOTOR DRIVE


6

1 R/B

RS 8

5
4

C14
0.1

2 Vcc

GND 7

3 CS

D6 6

4 SK

D1 5

R24
10k

CS/CU-A123K ( CWA12360 )

CS/CU-A93K ( CWA12346 )
JX1

2
1

SW2
PUMP DOWN

1
2
3
4
5

R13
10k

C9
0.01

R12
1k

R15
10k

C10
0.01

R14
1k

FAN
MOTOR
SW3
AUTO

(ZH5)

70

FAN
MOTOR

POWER CLOCK c
GENERATOR

34

32

60

MAGNETIC
RELAY A

BROWN
2

RED

50
30
20
10
7
5
3

40

60

80

100

120

140

50
30
20
10
7
5
3

20

Ambient Temperature (C)

50

OLP Characteristics
(Compressor)

YELLOW

Q1
DC114EKTX

C18
10
16V

GRAY

20

40

50

6
RY-M

C15
10
16V

11

(MX-5)
CN-STM

CN-C
(VH-3)
(GREEN)

1
2
3
4

10

Ultimate Trip Current (A)

Fig.1
PIPE TEMP. SENSOR
(20k 3950)

R26 +
15k

12V

30

C16
10
16V

IC4
78A05
I

ZNR1
511U

AVdc 35
AVref

POWER

26

Temperature (C)

Fig. 3

RED

ELECTROLYTIC CAPACITOR

C4
0.1

36

R27 +
20k

A56W2DEH1-5

BLUE

ANI0 33

25

30

GRAY

R34
150k

40

(PH4)
CN-TH

IC5
78N12H
REGULATOR
C1
3300
35V
(NHG)

AIR TEMP. SENSOR


(15k 3950)

ZNR2
511U

R1
5.1k

ANI1

23

ANI2

22

PIPE
TEMP

DEICE
DETECTION

GROUND
21

ANI4

20

ANI3

19

ANI5

18

ANI6

RY-H

17

RESET

RESET

20

R42
10k

WHITE

8MHz
OSC

ANI7

RY-M

P35

VDO1

P34

P36

16

AVss

15

C20
10
16V

XT2 37

P25

14 P33
R29

XT1 38

P23

12 P31

D2
A54MA723TA
+

R43
51k

RY-SHI

DB1
S1VD20
~
+

IC 39

11 P30

-10

COMPRESSOR
D3
A54MA165TA5

C21
0.01

47
46

Vss 42
X1

10

Temperature (C)

48

INTP0 43

IC1
A52D00226506

Indoor Heat Exchanger


Temp. Data
0

CAPACITOR
P03

P56

P57

20

YELLOW

BLACK

DISPLAY

P71

FUSE
2.0A

A56W2DEH1-5

BLACK
BLACK

P64

TIMER
SHORTEN
AUTO
OPERATION

P55

SSR2
CR1
CWA59015

RELAY DRIVE

TO50

P65

P66

P40

P67

P41

BUZ
BUZZER

P42

P43

P44

P45

P46

POWER CLOCK INPUT

P54

13 P32

C17
0.01

10 VDD0

C22
10
16V

R31
26.1k
R32
102k

P53

P24

PUMP-DOWN

RELAY
DRIVE
SIGNAL

STEPPING MOTOR
DRIVE SIGNAL

AUTO RESTART
AND
RANDOM AUTO RESTART

C23
0.01
R30
24k

SW1

30

10
RY-PWR

Ultimate Trip Current (A)

R28
10k

10

4
1

WHITE

5
R38 330
R39 330

RX1

11

1 2 3

COIL
REVERSING VALVE

4
R37 330

JX2

12

RY-PWR

P47
R36 330

RED

13

P52

RY-SHI

ORG

14

SSR2

15

SSR1

P51

SCK30

ORG

P50

RELAY DRIVE SIGNAL


3

SO30

SLEEP

2
R35 330

SI30

6
5
4
3
2
1

A54LNK3171B

TIMER

OFF/ON

RY-HOT

(MX-9)
CN-DISP
1
2
3
4
5
6
7
8
9

(PH-6)
CN-DISP

RELAY DRIVE

CN-FUSE1

ZNR2
ERZ-TCEAK471

Intake Air
Temp. Data

BLACK

Q5
A55DC143XKTX
16
A54LNK2172B

GRN

RY-SHI
RY-H
RY-M
SSR1
RY-HOT
SSR2

RELAY DRIVE

1 2 3

AC
(WHT)

FM
(BLU)
CT1
CWA40322

RY-HOT
CWA00161

TRS

INDICATOR

ORG

10k

Q6
A55DC143XKTX

10k

R41
10k

ECONOMY

HOT
(RED)

RELAY DRIVE

R45
10k

POWERFUL

CN-FUSE2

Q8
A55DC143XKTX

10k

Q7
A55DC143XKTX

40

BLACK

c
b

OVER LOAD
PROTECTOR

10k

c
R21
6.2k

Pipe Temp. Sensor


Intake Air Temp. Sensor

50

Resistance (k )

b
R22
2.2k

Ultimate Trip Current (A)

Q4
2SD148-4X

SSR1

R8
1k

BROWN

RY-PWR

D1
ERA15-01
TEST

R9
10k

1
2
3
4

TEMPERATURE
FUSE
113C

YELLOW

RY-PWR DRIVE
C11
0.01

6.3V
47
+

137k
FO 4

TEMPERATURE
FUSE
102C

ORANGE

VCC2 3

5 GND

POWER
SUPPLY
SWITCH

RED

OUT 2

6 CO

0.01
0.01

R16
5.1k

BLUE

330
7 IN-

R17
1k

1
2
3

WHITE

VCC1 1

8 IN+

1
2
3
4

AC 220-230V
50/60Hz
SINGLE PHASE

(PH3)
CN-RCV

PH302C

ELECTROLYTIC
CAPACITOR

RECEIVER

Voltage (V)

Downloaded from www.Manualslib.com manuals search engine

10

11
6/19/00, 10:52 AM

12

13

14

15

40

60

80

100

120

140

Ambient Temperature (C)

16

17

18

19

CS-A73K/A93K/A123K

How to use electronic circuit diagram

C1
47

R11
510k
R03
x2

+ C2
47

C9
0.01

R9
200k

R5
2.2
1/8W

R3
51

Q2
2SD602

7 min.

42 sec.

Time Save Control


Anti-Freezing Control

4 min.

Mode Jugdement
Soft Dry

R6
300

C6
0.1

(CLOSE:ON)

SW2

R12
51k

0 sec.

6 min.

36 sec.

On

10 min.
40 sec

60 sec.
4 sec.

Cooling

70 sec.

7 sec.

20 sec.

2 sec.

180 sec.

18 sec.

40 sec.

4 sec.

360 sec.

36 sec.

5 min.

30 sec.

Deodorizing Control
Soft Dry

Comp. Reverse Rotation Detection


Comp./Fan motor Delay Timer
SLo Timer
Intake Air Anti-Freezing Prevention
POWERFUL MODE
Random FM Timer (ECONOMY Mode)
Random Auto Restart Control

2 min.

0 sec.

1.6 sec.

0 sec.

8 sec.

8 sec.

16 min.

96 sec.

15 min.

15 sec.

5 sec.

5 sec.

0 ~ 150 sec.

0 sec

VDD

COM0

COM1

COM2

SEG0

SEG1

SEG2

SEG3

SEG4

SEG5

SEG6

OSC1

SEG 7 64
SEG8 63
SEG9 62
SEG10 61

21 PC3

SEG11 60

22 PC2

SEG12 59

23 PC1

SEG13 58

IC1

24 PC0

Remote Controller No.

Remarks
R13
51k
R14
51k

SEG14 57

25 PA0

SEG15 56

26 PA1

SEG16 55

27 PA2

SEG17 54

28 PA3

SEG18 53
SEG19 52

29 PA4

SEG20 51

30 PA5

SEG21 50

31 PA6
32 PA7

0 sec.

20 sec.
Off

(POWERFUL)

SOFT DRY: 10 min. operation

FAN SPEED
(TEMP )

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

SEG22 49
SEG 23
48

SELF
DIAGNOSIS

SLEEP

TIMER
ON

AIR SWING
AUTO

TIMER
OFF

TIMER
CANCEL

TIMER
SET

MODE
(TEMP )

CLOCK

SW2
0
ECONOMY

AIR SWING
MANUAL
(OFF / ON)
aI

LIQUID CRYSTAL DISPLAY

0 sec.

SEG24

60 sec.

Forced Operation

SEG25

0 sec.

SEG26

2 min. 58 sec.

Time Delay Safety Control

SEG27

1 sec.

SEG28

1 min.

SEG29

10 sec.

SEG30

10 min.

Real Timer

10

SEG31

1 min.

11

SEG32

6 sec.
48 sec.

12

20 RESET

RMO

test point
( When
Short-circuited )

1 hr.

13

19 VSS
DOOR OPEN/CLOSE
SW1

J-B

1 hr.

14

17 XOSC2
18 XOSC1

Test mode
Time

15

VLCD3

OSC2
X2
32.768kHz

VLCD2

C5
8P
(NPO)

TIMER TABLE

8 hrs.

R7
200k

X1
3.52Hz
(33P x 2)

R1
100k

RESET

Name

R8
200k

R2
1.5k

R4
22k

16

Sleep Mode Operation

BOTTOM VIEW

C4
8P
(NPO)

* Diode without indication .............. MA165


* Circuit Diagram is subject to change without
notice for further development.

Sleep Mode Waiting

TOP VIEW

CN1

VLCD1

15C

PRINT PATTERN
INDOOR UNIT PRINTED CIRCUIT BOARD

C8
0.01

BZ

17C

Q1
2SB710

PC7

16C

WIRELESS REMOTE CONTROL

CS-A73K/A93K/A123K

C7
0.01

LED1
SID1003BQ

PC6

27C

PRINT PATTERN
INDOOR UNIT PRINTED CIRCUIT BOARD

REMOTE CONTROL

PC5

Cooling

* Indications for resistance


a. K .... k
M ... M
W ... watt
Not indicated .... 1/4W
b. Type
Not indicated .......... carbon resister
Tolerance5%
.......... metal oxide resister
Tolerance1%

* Indications for capacitor


a. Unit
.... F
P .... pF
b. Type Not indicated ... ceramic capacitor
(S) .......... S series aluminium
electrolytic capacitor
(Z) .......... Z series aluminium
electrolytic capacitor
(SU) ....... SU series aluminium
electrolytic capacitor
(P) .......... P series polyester system
(SXE) ..... SXE series aluminium
electrolytic capacitor
(SRA)...... SRA series aluminium
electrolytic capacitor
(KME)......KME series aluminium
electrolytic capacitor

PC4

Intake air Temperature Discharge air


Pipe
temperature
setting
temperature temperature

CS-A73K/A93K/A123K

ELECTRONIC CIRCUIT DIAGRAM

Before using the circuit diagram, read the following carefully.


* Voltage measurement
Voltage has been measured with a digital
tester when the indoor fan is set at high fan
speed under the following conditions without
setting the timer.
Use them for servicing.
Voltage indication is in Red at all operations.

CS-A73K/A93K/A123K

J-B

OFF

ON

OFF

SHORT

ON

SHORT

Comp. ON 5 min. and above

Downloaded from www.Manualslib.com manuals search engine

10

11
6/19/00, 10:53 AM

12

13

14

15

16

17

18

19

You might also like