When in emergency case DM water from CST (Condensate Storage Tank) is

added to the Deaerator (when its level low) through initial make up line, that
times BFP (Boiler Feed Pump) suction strainer DP increases continually also
BFP discharge pressure drops occurs & when the Deaerator make up through
initial filling is stopped everything comes to normal condition (BFP discharge
press & also its DP). Why this is happening & what is the possible reason
behind this? So many times we faced this problem.

Ketika dalam keadaan emergency kasus DM water di dearator low


make up di tambah dari CST (Kondensat Storage Tank) ditambahkan
(make up) ke deaerator (ketika level low ) melalui make up line , BFP
(Boiler feed pump) Saringan suction DP meningkat terus dan juga
press discharge BFP press dropp & ketika deaerator make up
pengisian dari CST di stop .semuanya akan ke kondisi normal ( BFP
discharge press & DP suction stranner ). Mengapa hal ini terjadi &
apa alasan yang mungkin di balik ini? Begitu banyak sekali kita
menghadapi masalah ini.
Addition of significant cold water to the D/A. will reduce the dea
pressure, and cause a drop in the feedwater temp leaving the D/A. As
a result viscosity of the water increases significantly, and with a fine
mesh strainer the flow that can be passed will decrease.(as an
example viscosity increases 36% for a drop in temp of only 20 degrees
from 250 to 230C) Result is high strainer DP and reduced pump
output. Also impacting pump output will be the loss of dea pressure
accompanying the sudden introduction of cold water. Less suction
head will directly impact pump capacity
Selain cold water yang signifikan untuk D/A tersebut. akan
mengurangi tekanan D/A, dan menyebabkan penurunan temp feed
water ketika meninggalkan dearator tersebut. Sebagaimana viskositas
akibat dari water yg meningkat secara signifikan, dan dengan mesh
stranner aliran/flow yang bisa dilalui akan berkurang. (Sebagai contoh
viskositas meningkat 36% untuk penurunan temp hanya 20 C dari

250 ke 230C) Hasil nya high stranner DP dan mengurangi output


pompa. Juga berdampak keluaran pompa karena press D/A dropp.
Kurangnya suction head akan langsung berdampak pada kapasitas
pompa
You may be experiencing pump run out where demad on the feed system is
so great, which is why DA level drops to below the makeup setpoint, that the
suction strainer creates a restriction. This could cause suction pressure to
drop to the point where the BFP experiences cavitation causing pump output
to drop. What is the feed reg valve doing? Does it go full open during the
excursion? What is feed flow increasimg to and where on the pump curve
does this maximum flow sit? Just me speculating. I'm assuming the strainer
has been examined and found to be free of debris. If not, that's a good place
to start.
Anda mungkin mengalami saat pompa running di mana kebutuhan pada
feed water system yang begitu besar, yang mengapa level DA droop ,
suction stranner menciptakan restriction. Hal ini dapat menyebabkan press
suction turun ke titik di mana BFP mengalami kavitasi menyebabkan output
pompa menjadi droop.
The moment you add cold water to deaerator, the temperature of water in it
comes down. Thus there is increase in water density. By virtue of it NPSH
comes down. Which results into less mass flow /BFP Dis. Pressure of feed
water.
Simultaneously, since the density of water increased in deaerator (Due to
low temp. of water) the DP across suction strainer increases.
saat Anda menambahkan cold water untuk deaerator, temp water di
dalamnya turun. Jadi ada peningkatan kepadatan air(water density). Secara
bersamaan, karena kepadatan air meningkat di deaerator (Karena temp
rendah pada water) DP di suction stranner meningkat