You are on page 1of 31

F & SC Serial Access Control Station

Installationinstruction
Version:1.1.1
Date:June2010

AboutThisManual
This document describes the F & SC Serial Access Control Station
installationguideandwiringinstruction.

AboutthisGuide
l

The F&SC Access Control Station User guide is designed to provide

information to install the F& SC serial Access Control Station, for operation and
configuration,pleaserefertothecorrespondingusersmanual.

Notallfunctiontheseguidesintroduceavailableincombination,all

isoption.
l

About your machine function, please consult our company

technicalpersonnelorthesalespersonnel.

Informationinthisdocumentissubjecttochangewithoutnotice.

AccessControlStationInstallationGuide

Contents
1BeforeInstalling ...................................................................................1
1.1Noticeaboutinstalling...............................................................1
2SystemConfiguration ...........................................................................4
2.1Theillustrationofsystemconstruction......................................4
2.2Thesketchmapofcommunication ............................................5
3.Installation ............................................................................................6
3.1Fixingmountingplate................................................................6
3.2Connectwithperipheralequipment ...........................................7
3.2.1DoorSensor ....................................................................9
3.2.2ReleaseButton ................................................................9
3.2.3Alarm ..............................................................................9
3.2.4Conntionwithlock........................................................10
3.2.5Ethernetconnection ......................................................16
3.2.6ConnectionwithRS232 ................................................18
3.2.7ConnectionwithRS485 ................................................18
3.2.8Wiegandoutput .............................................................20
3.2.9Powerconnection..........................................................21
3.2.10ConnectwithexternalWeigendreader .......................21
3.3FixingAccessControlStation .................................................22
4.FasteningAccessControlStation ......................................................23
5.Others.................................................................................................24
5.1Reset ........................................................................................24
5.2Antidismantlebutton ..............................................................24
5.3Cable doorbell..........................................................................25
SCSeriesrechargeablebatteryspecifications .......................................26

AccessControlStationInstallationGuide

1BeforeInstalling
1.1Noticeaboutinstalling
Access Control Station is a massproduced product. It strictly tested
complywiththestandardofChina,U.S.A,andEU. Thisfilecontains
importantinformation.Itisbetterforyoutoreaditcarefullypriortouse.
If you ignore it, the incorrect installation may cause the unit damage.
Although we could do our best to offer you service, the neglect to the
filecouldcauseunwantedcostforyou.
1.Beforeinstallation,pleasemakesurethepoweriscutoff,becauseitis
verydangerousifthepowerison.Theshortcircuitofpowercablemay
causethecorepartsdamage.
2.Allexposedpartofconnectionwireendcannotbeexceeded5mmto
prevent the bared wire accidental connection which leads to machine
breakdown.Andalsosuggestusingdifferentcolorcabletoconnect.
3.Intheplacewherethestaticisstrongorinwinter,pleaseconnectthe
groundingfirstly,inordertopreventtheinstantmassstaticdamagethe
machine.
4. Connect power supply with device in the last for the wiring
connection.Ifyoufindanyunusualthingoccur,pleasefirstlycutoffthe
power,thengotoexamine.Keepinmind:wiringoperationunderpower
onwillleadto machinesuddendamagewearenotliablefordamages
andtroubleduetosuchoperation.
1

AccessControlStationInstallationGuide

5.Theheighttomountdeviceisabout1.41.5meter
6. Afterinstallation,pleasetakeoffprotectionfilmonthefingerprintsensorto
getbestrecognizeresult.
7. Afterinstallationfinish,when go totest theexitdoorbutton, please
keep a personal in the outside, because sometimes the accidental issue
canbringonyouarenotabletogooutside.
8.Ourequipmentofferanautomaticallyfunction,pleaseaftertheinstalling
finish.Runtheautotestfunctiontoconfirmtheinstallationfinish.
9.Werecommendusingabovethe12V/3AdirectcurrentsupplyforZK
softwares access control device, electricity lock better to powered by
12VDC, and no more than 1.5 A electric current At this time, the
electric current of supply should be above1A than lock power. If the
parameter oflock powersurpassesthisscope, please connecttechnical
personnel.Ifthepowerhadnotmetaboverequests,itpossiblycausesto
beunablenormallytodrivetheelectricitylock,evendamagethedevice.
10.Beforedevicetobeconnectedpleasereadandalwaysfollow"Quick
connect Guide" closely. Because the wrong wiring will cause the core
block and sensor to burn out, insult in device to break down, at this
causeZKSoftwareisnotliableforanydamagesandtrouble.
11.Ifthespacebetween poweradaptersand deviceistoolong,please
do not use the twistedpair or other type ferrules for the power wire.
When the power wire is choused, you should consider attenuation of
voltage,whichhaspassedlongdistancetransfer.
12. Please use specialized RS485 cable and the RS232/485 converter
with power to hookup the network, the bus structure apply to connect
2

AccessControlStationInstallationGuide

witheachdevice.Whenalongcableisusedtotransfersignal,itisneed
toconnectamatchingresistancetoreceiver,anditsvalueis120.
13. Other more details items please see also the user manual, the
operatinginstructionsandthe appendixandsoon.

AccessControlStationInstallationGuide

2SystemConfiguration
2.1 Theillustrationofsystemconstruction

AccessControlStationInstallationGuide

2.2Thesketchmapofcommunication
Access Control Station directly connects with PC through RS232 or
TCP/IP

AccessControlStationconnectswithPCthroughRS485network

3 AccessControlStationconnectswithPCthroughTCP/IPnetwork

AccessControlStationInstallationGuide

3.Installation
3.1Fixingmountingplate
Take out a Access Control Stationdismantle the screw between
machinebodyandmountingplateuntilitisout,seefigure(1).
Carefullytakeupthebottomofmountingplate,seefigure(2),pushit
up,seefigure(3),thentakeawaythemountingplate.
Determine the position of mounting plate on the wall. The Access
Control Station should be mounted on the external wall of the door
approximately 1400mm from the ground to the unit bottom. After the
positionis determined, you could drillahole(18mm*20mm)forcable
out,seebelowfigureshadowedpart.
Make the hole of mounting plate meet the drilled hole on the wall,
Usethescrewtofixitonthewall,(forthedetailspleaseseefollowing
figure)
after installation, please make sure the mounting plate is reliable,
fasten,notloosed.

AccessControlStationInstallationGuide

3.2Connectwithperipheralequipment
Caution:Donottoconnectperipheralequipmentbeforethepower
of the device is cut down, otherwise it is possible to damage the
devicebadly.
Pleasefollowinstructiontoconnectperipheralequipment
Doorsensorconnectionsensor,GND
ExitbuttonconnectionButtonGND
AlarmconnectionAlarm+,Alarm
DoorlockconnectionNC,COM,NO
Ethernetconnection RJ451,RJ452,RJ453,RJ454
RS232connection232RX,232TX,GND
RS485connection485A,485B
WiegandoutputconnectionWD0,WD1,GND
CableBell(Bell+,Bell)
Powerconnection(GND,+12V)

Cablesocket
7

AccessControlStationInstallationGuide

Alarm -

RJ451

Alarm +

RJ452

NC

RJ453

COM

RJ456

NO
Button
GND
Sensor

WD0

Bell+

WD1

Bell

GND
232RX

GND

232TX

+12V

GND

ThedefinitionofsocketwithoutWiegandinput

485A
485B

BEEP
GLED
RLED
WD1
WD0
GND
+12V

ThedefinitionofsocketwithWiegandinput

Jump
8

AccessControlStationInstallationGuide

3.2.1DoorSensor

The door sensor is used to detect the door openclose status, Access
Control Station can monitor if the door has been unauthorized open
through the door sensor, at this time it can output a alarm signal,
moreover, Access Control Station can trigger prompt warning if after
surpassingatimedperiod,thedoorstillopen.
3.2.2ReleaseButton

Theexitbuttonisinstalledforindooroperation.Whentheswitchofthe
button is close, the door will open. The distance is approximately
1400mm from ground to exitbutton bottom. Make sure that the
exitbutton position is to align correct, upright and the connection is
accurateandreliable.(Unused exposedend ofcable shouldbecut off,
and use insulating tape to wrap it.) Pay attention to electromagnetic
disturbance.(Forexample:Thelightswitch,thecomputerandsoon)
3.2.3Alarm

Access Control Station alarm output is a switch signalit is able to


connect with simple alarm by serial circuit, it also apply to top grade
alarm and monitor system as a trigger signal( this machine alarm
functiononlysupport12VDCWarner)

AccessControlStationInstallationGuide

3.2.4Conntionwithlock
The way of installing door lock depends on the type of lock and local
condition. Internal resistor, which comes from long distance transfer,
should be taken into consideration when selecting the cable of electric
power.Thedoorlockshouldbeinstalledreliableandstable.Ensurethe
wiring is correct. For the strike lock and electromagnetic lock, you
should pay attention to positive and negative terminal connection. The
unused bare end of wire should be cut off and use insulating tape to
wrapit.Thedelaytimeofstrikelockisadjustableaccordingtodifferent
conditions.
Normally close (NC), under normal state the equipment keeps up
closed, if force the equipment open, the circuit cut off, brings out the
statechange.
Normally Open (NO), under normally state the circuit is cut off, if
forcetheequipmentopen,thecircuitwillbeclosed,andproduceastate
10

AccessControlStationInstallationGuide

change.
PowerGroundGND
Currentloopground
Inputterminalofdoorsensor SensorGND theinputportofdoor
sensor accepts thesignalwhichcomefrom normally closedcontact
todetectthedooropeningandclosingstate,whenthedoorisinclosed,
thecontactkeepinclosedstate,ifthedoorisopenedbysomeone,the
circuitbreak,thusbringoutstatechange.Ifunauthorizeduseropensthis
doororopeningtimeistoolong,thecontrollerwillsendalarm
Inputterminalofreleasedoorbutton
Button GND
Theinputport
of release door button accepts the signal which come from normally
opened contact to indicate that somebody want to go out, the input
equipmentsuchasactiondetector,presssensitivityfloorboardor
exitdoorbuttonallserveassourcetosendsignalifnobodysend out
request to want to go out, the input keep disconnection , if somebody
want to go out,they triggerrelease doorbutton,the circuitisclosed.
Produce state change, the controller responded to the request, unlock
andpermitdoorserve aspassagemode.
Note1theprocessofperformancetounlockdooriscontrolbyrelay,
whenyouinstall doorlock,therearetwothingyoumustthinkabout,
safetyandsecurity,inotherwords,doyouwantwhichresult thatis
if losecontrolofthisdoor,thedoorisstillinsafetylostcontrolbut
safety orif losecontrol ofthis door,the doorstillissecurity lost
controlbutsecurity
2
WhentheAccessControlSystemconnectedwith Electriclock,
topreventtheselfinductanceEMFtoaffecttheaccess controlsystem,
you need to parallel one FR107 diode (do not reverse the polarity) .
11

AccessControlStationInstallationGuide

Pleaseusetheequippeddiodeinthepackage.

Lostcontrolbutsafetyisthatthe powersupplycut off(maybethe


powersupplyiscutorthecontrollerlosecontrolofitself,thedoorwill
beopenautomatically,and permit everybodyfreelyto passinand out,
thedoorisnotabilitytobecloseduntilthesystempoweron,thesetype
of doors are installed in the protective area which ensure everybody is
abletopassinandout. Onerepresentativeapplicationoflostcontrol
butsafetyistouseelectromagnetismlock,undernormalpowersupply,
thedooriscontrolledbythecontroller,oncethepowersupplybreakoff,
theelectromagnetismlockwilllosemagnetismanddoesnottakeeffect,
thedoorbecomeapassagemode
Lostcontrolbutsecurityisthatthe powersupplycutoff,the door
willbelockedautomatically,donotpermitexternalpersonaltocomein,
butpermitinternalpersonalgoout,thedoorisnottobeunlockeduntil
the system power supply is in gear. Make sure that the door of lost
control but security will be installed in the area, which needs to be
protectedthroughfairandfoul.Onerepresentativeapplicationoflost
controlbutsecurityistouseelectricallock,ifthepowersupplybreak
off, the external personal is not able to open the door, but the internal
personcanopenthebymanualoperation.
In the following three cases, we recommend that fingerprint machine
andlockbepoweredseparately.
1) The working voltage of the lock is DC12V, but the current
differenceofthefingerprintmachineandthelockdoesntexceed1A.
2)ThelockvoltageisnotDC12V.
12

AccessControlStationInstallationGuide

3)Thedistancebetweenlockandfingerprintmachineistoofar.

1NClockconnectionAccessControlStationandlockpowerbyone

adaptertogether,Jump2,3pinclosed.

Lock

2NOlockconnection AccesscontrolStationandlock poweredby

oneadaptertogether,Jump2.3pinclosed.

13

AccessControlStationInstallationGuide

Lock

3theoutputrelaysignalbyAccesscontrolstation,NClockconnection

AccessControlStationandlockpoweredbyindependent adapters
jump1,2closed

14

AccessControlStationInstallationGuide

Lock

LockPower

4theoutputrelaysignalbyAccesscontrolstation,NOlockconnection

(AccessControlstationandlockpoweredbyindependentadapter

LockPower

Lock

15

AccessControlStationInstallationGuide

3.2.5 Ethernetconnection

1AccessControlStationconnectswithPCthroughcrosscable

2AccessControlStationconnectswithPCthroughnetworkandHUB

tocreatealocalnetwork

16

AccessControlStationInstallationGuide

3)RJ45plugwiringdiagramsforEthernet
a)RJ45plugstandard

b)Ethernet10/100BaseTCrossoverCable
mostly apply to HUB and Switchor directly connect two Ethernet
terminals(notthroughHUB),fullysupport10BaseTand100BaseTX.
Plug1 Pin
Pin Plug2
TX+
1 <> 3
RX+
TX
2 <> 6
RX
RX+
3 <> 1
TX+
RX
6 <> 2
TX
c)Ethernet10/100BaseTStraightThruCable
Support10BaseTand100BaseTX
applytoconnectwithnetworkcard
andHUBornetworkoutlet
sometimeitiscalled(whips)
Wiringstandard Pin
Color Pin Wiringstandard
TX+
1 < whiteorange >1
TX+
TX
2 < Orange
> 2
TX
RX+
3 < whitegreen > 3
RX+
4 < Blue
> 4
5 < Bluewhite > 5
RX
6 < Green
> 6
RX
7 < Whitebrown > 7
8 < Brown
> 8
17

AccessControlStationInstallationGuide

3.2.6ConnectionwithRS232
ThedefinitionofPCconnectionwithAccessControlStation
PCSerialPort

AccessControlStationserialport

Pin2Rxd

Pin5Txd

Pin3Txd

Pin4Txd

Pin5Gnd

Pin6Gnd

3.2.7ConnectionwithRS485
Thedefinitionofterminalconnection
Terminal

Function

Pin1485A

RS485communication+

Pin2485B

RS485communication

18

AccessControlStationInstallationGuide

19

AccessControlStationInstallationGuide

3.2.8Wiegandoutput
AccessControlStationprovidestandardWiegand26output,whichcan
be connected to most of access controllers, like the way of connecting
withaIDreaderorpasswordkeyboard.Thedistancefromthecontroller
todevicecannotbemorethan15meter(ifthesignalmustbetransferred
much further or there is a strong interference around, please adopt a
Wiegandsignalamplifier)
Mote:no matterthe deviceis poweredbyaccesscontrolleror not,the
ground ports of them have to be properly together to ensure the
Wiegandtransferreliable
Terminal

Function

Pin1WD0

OutputWieganddata0signal

Pin2WD1

OutputWieganddata1signal

Pin3GND

Ground

20

AccessControlStationInstallationGuide

3.2.9 Powerconnection
Thisdeviceispoweredby12VDC.Itscurrentisapproximately50mAin
the ready work status and 400mA in the work status. The power is
conducted along with the terminal you can use the 12V4Asupply
adapter that is provided along with the device. The detail about
connectionisasfollow.
Terminal

Function

Pin1GND

Powernegative

Pin2PWR

Powerpositive

The following figure is an example, which takes a provided power


adaptertoconnect

3.2.10 ConnectwithexternalWeigendreader
AccesscontroldevicewhittheWeigandinputfunctionisabletoconnect
withcardreader,whichislocatedinoutdoororindoor,controlthedoor
bythecontrollertogether,thecablewhichbetweenaccesscontrollerand
externalcardreaderisnomorethan90meter.

21

AccessControlStationInstallationGuide

3.3FixingAccessControlStation
Confirmallconnectionplugscorrectly.
Align back ironplate of Access Control Station body to mounting
plate properly, and push it up, see figure1, then push device
backward,seefigure2.
Turnandtieupthescrewbottom.
After finishing installation, make ensure the body of device is fixed
tightly.

22

AccessControlStationInstallationGuide

4. FasteningAccessControlStation
Afterallsysteminstallation finished, makeatestand examine priorto
poweron,inspectwhetherthelockdriverisOKornot,formoredetails,
pleaseseeUserGuideandSoftwareManual
thegreenLEDbeginstoglitterafterpowerup.
entermenuOption Autotest.
entermenuUsermanageUserEnrollFingerprintEnrollEnroll
a fingerprint, and use the fingerprint to test access control system and
doorlock..
ifthereisnoanyproblem.Pleasedeletethisenrolledfingerprint.

23

AccessControlStationInstallationGuide

5. Others
5.1Reset
Duetooperationerrororotheraccidence,whichleadsthemachinenot
towork,youcanrestartmachinethroughresetkey.
take asmalltoolwhichdiameterisnomorethan2mm.
findresetmarkofresontheleftsmallholeonthebottomofdevice,
seefollowingfigure.
Usethetoolplugintotheholerefertothepictureonright,thenplug
out.Themachineisabletorestart.

Resetkey

5.2 Antidismantlebutton
Antidismantlebuttonisonmiddleofdevice,whosefunctionisrealized
by backcover pressing the antidismantle button. When the device is
beingdismantled,itwillsendanalarmsignalthroughtheterminal.

24

AccessControlStationInstallationGuide

5.3Cabledoorbell
Thereisakeywhichisremarkas icon

isusedfordoorbell.

onthekeypad,thiskey

DoorBell

Putthedoorbellintheproperplace,pressthedoorbellkeyonthedevice,
pleaseseecirclemarked,afterthedoorbellreceiveasignal,itwillring.
NoteBecause the terminal and key our provided is used for cable
doorbell,mustjointhepowerintotheelectricround.

25

AccessControlStationInstallationGuide

SCSeriesrechargeablebatteryspecifications
specifications
n Model:MS621F
n Nominalvoltage(V):3
n Chargingvoltage(standardcharge voltage):2.8V3.3V
(3.1V)
n Nominalcapacity(mAh):5.5
n Internalresistance():80
n Standardchargeanddischargecurrent(mA):0.025
n Thelargestdischargecurrent(continuous)(mA):0.25
n Lifecycle(times):100%chargeanddischarge:20020%
chargeanddischarge:1000
n Size(mm):diameter:6.8Height:2.1
n Weight(g):0.23
Features
n Dischargecapacity
n 3.3V2.0Vwiththehighvoltageatthesametime,youwill
receivealargedischargecapacity.Chargeanddischarge
cycleslongulife
n Underthe3.3V2.0Vthechargeanddischargeconditions
(dischargedepthof100%),canachievemorethan200
roundsofthechargeanddischarge.
n Excellenceinthedischarge
n Adischargeto0.0Vsofar,canalsoshowastable
dischargecapacity.

26

AccessControlStationInstallationGuide

n UL(UnderwritersLaboratoriesInc)specifications(ULFile
No.MH15628)
Application
n Mobile,officeequipment,andotherelectronicequipment sever
asthestandbypowerforclockfunctionsofkindsofmemory.
n dischargencharacteristics

Charge: Max 0.1 mA/96 hours


(rated current, rated voltage
charging)
Discharge:25A/cov=2.0V
(ratedcurrentdischarge)

Dischargecharacteristics
Proposed rated voltage. Because of the charge current restrictions, the need to
connecttothecurrentlimitresistance
Nominalcapacity:3.3V2.0V,/FSproductsinthedischargecapacityof3.1V2.0V
withinthetypicalscope
InternalresistancebytheexchangevalueofAlternatingCurrent
The largest discharge current: the available capacity of about 50 percent the
currentcapacityof
Maintaintheminimumcapacityof50percent
The number of repeated charge 100% and 20% of the nominal capacity as the
standard

27

Informationinthisdocumentissubjecttochangewithoutnotice
PrintedinChina