You are on page 1of 37

Installationinstructionforiclockaccesscontrol V1.1.

iClock

Access

control

Installation

instruction
Version:1.1.1
Date:June2010

AboutThisManual
This document describes the iClock access control serials products
installationguideandwiringinstruction.

Contents

AboutthisGuide
l

The TFT screen Fingerprint Machine User guide is designed to

provide information to install theTFT screen Fingerprint Machine, for


operation and configuration, please refer to the corresponding users
manual.
l

Notallfunctiontheseguidesintroduceavailableincombination,all

isoption.
About your machine function, please consult our company technical
personnelorthesalespersonnel

Informationinthisdocumentissubjecttochangewithoutnotice

Installationinstructionforiclockaccesscontrol V1.1.1

Contents
1.BeforeInstalling ...................................................................................1
1.1Noticeaboutinstalling...............................................................1
2.SystemConfiguration ..........................................................................4
2.1Theillustrationofsystemconstruction.......................................4
2.2Thesketchmapofcommunication ............................................5
3.Installation ............................................................................................6
3.1FixMountingPlate ....................................................................6
3.2Connectwithperipheralequipment ...........................................7
3.2.1Doorsensorconnection ..................................................9
3.2.2Exitbuttonconnection..................................................10
3.2.3Alarmconnection..........................................................10
3.2.4Doorlockconnection....................................................12
3.2.5Ethernetconnection ......................................................17
3.2.6RS232connection .........................................................19
3.2.7RS485connection .........................................................20
3.2.8Wiegandoutputconnection...........................................21
3.2.9ConnectwithexternalWeigendreader .........................22
3.2.10Powerconnection........................................................23
3.3Fasteningfingerprintmachine .................................................25
4.Testandexamineafterinstallation ....................................................26
5.Others.................................................................................................27
5.1Reset ........................................................................................27
5.2Antidismantlebutton ..............................................................28
5.3UsingUflashdisk ...................................................................28
5.4BuiltinEMcardreader(Optional) .........................................28
5.5BuiltinMIFAREcardreader(Optional).................................29

Contents

5.6Cable doorbellOptional....................................................29
6.Troubleshooting ................................................................................31

Installationinstructionforiclockaccesscontrol V1.1.1

1.BeforeInstalling
1.1Noticeaboutinstalling
TFT screen Fingerprint Machine is a massproduced product. It
strictly follows to the criteria of manufacture and inspection of China,
U.S.A, and EU. This file contains important information. It is better
for you to read it carefully prior to use. If you ignore it, the incorrect
installationmaycausetheunitdamage. Althoughwecoulddoourbest
toofferyouservice,theneglecttothefilecouldcauseunwantedcostfor
you.
1.Beforeinstallation,pleasemakesurethepoweriscutoff,becauseit
is very dangerous if the power is on. The shortcircuit of power cable
maycausethecore board damage.
2.Allexposedpartofconnectionwireendcannotbeexceeded5mm
topreventthebaredwireaccidentalconnectionwhichleadstomachine
break down. And using different colour cable to connect is
Recommendation.
3.Intheplacewherethestaticisstrong orinwinter,pleaseconnect
thegroundingfirstly,inordertopreventtheinstantmassstaticdamage
themachine.
4. Connect power supply with device in the last for the wiring
connection.Ifyoufindanyunusualthingoccur,pleasefirstlycutoffthe
power,thengotoexamine.Keepinmind:wiringoperationunderpower
onwillleadto machinesuddendamagewearenotliablefordamages
1

BeforeInstallation

andtroubleduetosuchoperation.
5.Theheighttomountdeviceisabout1.41.5meter
Afterinstallation,pleasetakeoffprotectionfilmonthefingerprint sensorto
getbestrecognizeresult.
6.Afterinstallationfinish,whengototesttheexitdoorbutton,please
keep a personal in the outside, because sometimes the accidental issue
canbringonyouarenotabletogooutside.
7.Ourequipmentoffer anautomaticallyfunction,pleaseaftertheinstalling
finish.Runtheautotestfunctiontoconfirmtheinstallationfinish.
Inordertoguaranteemachinerunforlongtime,wesetanautosleep
andwake up functionintheexitfactory, pleasecarefully examinethis
functionnormallysettingbeforeusing.
8.We recommend using above the 12V/3A directcurrent supply for
ZKsoftwaresaccesscontroldevice, electricitylockbettertopowered
by12VDC,and no morethan1.5 Aelectriccurrent Atthistime,the
electric current of supply should be above1A than lock power. If the
parameter oflock powersurpassesthisscope, please connecttechnical
personnel.Ifthepowerhadnotmetaboverequests,itpossiblycausesto
beunablenormallytodrivetheelectricitylock,evendamagethedevice.
9. Before device to be connected please read and always follow
"QuickconnectGuide"closely.Becausethewrongwiringwillcausethe
coreblockandsensortoburnout,insultindevicetobreakdown,atthis
causeZKSoftwareisnotliableforanydamagesandtrouble.
10.Ifthespacebetweenpoweradaptersanddeviceistoolong,please
do not use the twistedpair or other type ferrules for the power wire.
When the power wire is choused, you should consider attenuation of
voltagewhichhaspassedlongdistancetransfer.
11.PleaseusespecializedRS485cableandtheRS232/485converter
with power to hookup the network, the bus structure apply to connect
2

Installationinstructionforiclockaccesscontrol V1.1.1

witheachdevice.Whenalongcableisusedtotransfersignal,itisneed
toconnectamatchingresistancetoreceiver,anditsvalueis120.
12. Other not details items please see also the user handbook, the
operatinginstructionsandtheappendixandsoon

SystemConfiguration

2.System Configuration
2.1Theillustrationofsystemconstruction

Installationinstructionforiclockaccesscontrol V1.1.1

2.2Thesketchmapofcommunication
Fingerprint machine directly connects with PC through RS232 or
TCP/IP

FingerprintmachineconnectswithPCthroughRS485network

FingerprintmachineconnectswithPCthroughTCP/IPnetwork

Installation

3.Installation
3.1FixMountingPlate
Takeoutafingerprintmachine
dismantlethescrewbetweenmachine
bodyandmountingplateuntilitisout,seefigure(1).
Carefullytakeupthebottomofmountingplate,seefigure(2),pushit
up,seefigure(3),thentakeawaythemountingplate.
Determinethepositionofmountingplateonthewall.Thefingerprint
machine should be mounted on the external wall of the door
approximately 1400mm from the ground to the unit bottom. After the
positionis determined, you coulddrillahole(18mm*20mm)forcable
out,seebelowfigureshadowedpart.
Make the hole of mounting plate meet the drilled hole on the wall,
Usethescrewtofixitonthewall,(forthedetailspleaseseefollowing
figurea,b,c,d)
After installation, please make sure the mounting plate is reliable,
fasten,notloosed.

Figure1
6

Installationinstructionforiclockaccesscontrol V1.1.1

3.2Connectwithperipheralequipment
Caution:Donottoconnectperipheralequipmentbeforethepower
of the device is cut down, otherwise it is possible to damage the
devicebadly.
Pleasefollowinstructiontoconnectperipheralequipment

Doorsensorconnection
Exitbuttonconnection
Alarmconnection
Doorlockconnection
Ethernetconnection
RS232connection
RS485connection
Wiegandoutputconnection
Powerconnection

Installation

Table 1 the definition of the Pin of TFT screen Fingerprint Machine


connector
J12,Pinconnectoronmiddlebelowoftherearpanel(fromthetop)
1st

485B

ConnecttoRS485B

2nd

485A

ConnecttoRS485A

3rd

GND

ConnecttoRS232GND

4th

TXD

ConnecttoRS232TXD

5th

RXD

ConnecttoRS232RXD

6th

GND

ConnecttoWeigandoutGND

7th

WD1

ConnecttoWeigandoutWD1

8th

WD0

ConnecttoWeigandoutWD0

Tie
together

up

Tie
together

up

Tie
together

up

J2,4Pinconnectoronmiddleaboveoftherearpanel(fromthetop)
1st

RJ456

ConnecttoRJ45plugwiring 6

2nd

RJ453

ConnecttoRJ45plugwiring 3

3rd

RJ452

ConnecttoRJ45plugwiring 2

4th

RJ451

ConnecttoRJ45plugwiring 1

Tie
together

up

J17,7Pin connector onright sidebelow of the rear panel (from the


top)
1st

Bell+

ConnecttoCableBell+

2nd

Bell

ConnecttoCableBell

3rd

BEEP

Spare

4th

GLED

Spare

5th

RLED

Spare

6th

INWD0

ConnecttoWeigandinput

7th

INWD1

ConnecttoWeigandinput
8

Tie
together

up

Tie
together

up

Installationinstructionforiclockaccesscontrol V1.1.1

J7,9pinconnectoronleftsideaboveoftherearpanel(fromthetop)
1st

NC2

ConnecttoAlarmNCterminal

Tie
up
together

2nd

COM2

ConnecttoAlarmCOMterminal

3rd

NO2

ConnecttoAlarmNOterminal

4th

NC1

ConnecttoLockNCterminal

5th

COM1

ConnecttoLockCOMterminal

6th

NO1

ConnecttoLockNOterminal

7th

Button

ConnecttoReleasebutton

8th

GND

ForDoorsensorandreleasebutton

9th

Sensor

ConnecttoDoorsensor

Tie
up
together
Tie
up
together

J1,2Pinconnectoronleftsidebelowoftherearpanel(fromthetop)
1st

GND

ConnecttoPowerGND

2nd

+12V

ConnecttoPower+12v

Tie
together

up

3.2.1Doorsensorconnection
Thedoorsensorisusedtodetectthedooropenclosestate,TFTscreen
FingerprintMachinecanmonitorifthedoorhasbeenunauthorizedopen
through the door sensor, at this time it can output a alarm signal,
moreover,TFTscreenFingerprintMachinecantriggerpromptwarning
ifaftersurpassingatimedperiod ,thedoorstillopen.

Installation

3.2.2Exitbuttonconnection
The exitbutton is installed for indoor operation. When switch the
button to close, the door will open. The distance is approximately
1400mm from ground to exitbutton bottom. Make sure that the
exitbutton position is to align correct, upright and the connection is
accurateandreliable.(Unused exposedend ofcable shouldbecut off,
and use insulating tape to wrap it.)Pay attention to electromagnetic
disturbance.(Forexample:Thelightswitch,thecomputerandsoon)

3.2.3Alarmconnection
TFT screen Fingerprint Machinealarm output is a switch signalit is
abletoconnect withsimplealarmbyserialcircuit,italsoapplytotop
gradealarmandmonitorsystemasatriggersignal(thismachinealarm
10

Installationinstructionforiclockaccesscontrol V1.1.1

functiononlysupport12VDCWarner)

ConnecttheNormalClose Alarm

ConnecttheNormalOpenalarm

11

Installation

3.2.4Doorlockconnection
The way of installing door lock depends on the type of lock and local
condition. Internal resistor, which comes from long distance transfer,
should be taken into considerationwhen selecting the cable of electric
power.Thedoorlockshouldbeinstalledreliableandstable.Ensurethe
wiring is correct. For the strike lock and electromagnetic lock, you
should pay attention to positive and negative terminal connection. The
unused bare end of wire should be cut off and use insulating tape to
wrapit.Thedelaytimeofstrikelockisadjustableaccordingtodifferent
conditions.
Selectelectriclock Itisbettertouseelectricdropboltforthetwo
direction opening glass door (both open to inside or outside
direction), for the single opening wood door in company internal , we
recommend to use magnetic lock, the magnetic lock also be called as
electric magnetic lock,. The magnetic lock is more reliable than the
electric drop bolt, but the electric drop bolt is much safer than the
magneticlock.Inthesmalllivingcommunity,itisbettertouseelectric
drop bolt and magnetic force lock. The electric control lock gives out
higher noise the electric control lock is commonly used to building
communication.Nowthereisasoundlesselectriccontrollockwhichis
able to be applied. Please pay attention, the lock is made of iron and
easy rust, so you must beware of not exposing it to water or harsh
condition, there are some other electric locks available, we dont
recommendyoutousethem.
Connectwithelectriclock

12

Installationinstructionforiclockaccesscontrol V1.1.1

Inputterminalofreleasedoorbutton
Button GND
Theinputport
of release door button accepts the signal which come from normally
opened contact to indicate that somebody want to go out, the input
equipmentsuchasactiondetector,presssensitivityfloorboardor
exitdoorbuttonallserveassourcetosendsignalifnobodysend out
requesttowanttogoout,theinput disconnection,ifsomebodywant
to go out, they trigger release door button, the circuit is closed.
Producestateischanged,thecontrollerrespondedtotherequest,unlock
andpermitdoorserveaspassagemode.
Note 1the process of performance to unlock door is control by
relay, when you install door lock, there are two thing you must
think about, safety and security , in other words, do you want
whichresult thatisif losecontrolofthisdoor,thedoorisstillin
safety lostcontrolbutsafety oriflosecontrolofthisdoor,the
doorstillissecurity lostcontrolbutsecurity
2 When the Access Control Systemconnected withElectric
lock,topreventtheselfinductanceEMF toaffecttheaccesscontrol
system, you need to parallel one FR107 diode (do not reverse the
polarity).Pleaseusetheequippeddiodeinthepackage
Lostcontrolbutsafetyisthatthe powersupplycut off(maybethe
powersupplyiscutorthecontrollerlosecontrolofitself,thedoorwill
beopenautomatically,and permit everybodyfreelyto passinand out,
thedoorisnotabilitytobecloseduntilthesystempoweron,thesetype
of doors are installed in the protective area which ensure everybody is
abletopassinandout. Onerepresentativeapplicationoflostcontrol
butsafetyistouseelectromagnetismlock,undernormalpowersupply,
thedooriscontrolledbythecontroller,oncethepowersupplybreakoff,
13

Installation

theelectromagnetismlockwilllosemagnetismanddoesnottakeeffect,
thedoorbecomeapassagemode
Lostcontrolbutsecurityisthatthe powersupplycutoff,the door
willbelockedautomatically,donotpermitexternalpersonaltocomein,
butpermitinternalpersonalgoout,thedoorisnottobeunlockeduntil
the system power supply is in gear. Make sure that the door of lost
control but security will be installed in the area, which needs to be
protectedthroughfairandfoul.Onerepresentativeapplicationoflost
controlbutsecurityistouseelectricallock,ifthepowersupplybreak
off, the external personal is not able to open the door, but the internal
personcanopenthebymanualoperation.
TheworkingpowerofthefingerprintaccesscontrolterminalisDC12V,
andtheworkingcurrentisapproximate400mA.Iftheworkingpowerof
the lock is DC12V while its working current is 1000mA much lower
than the current of fingerprint machines power, it is allowed to
fingerprintmachine andlockworktogetherbyonepowersupply.
Inthefollowingthreecases,werecommendthatthefingerprintmachine
and the lock is powered separately. you can following picture3 and
picture4.
1) The working voltage of the lock is DC12V, but the current is
differenceofthefingerprintmachineandthelockdoesntexceed1A.
2)ThelockvoltageisnotDC12V.
3)Thedistancebetweenlockandfingerprintmachineistoofar.

14

Installationinstructionforiclockaccesscontrol V1.1.1

NOLOCK

Picture1 Powerbyonesupply

NCLOCK

Picture2 powerbyonesupply

15

Installation

NCLOCK

LockPower

Picture3

LockPower
NOLOCK

Picture4
16

Installationinstructionforiclockaccesscontrol V1.1.1

3.2.5Ethernetconnection
The TFT screen Fingerprint Machine provide two ways connect
Ethernet

1).TFT screen Fingerprint Machine connects with PC through cross


cable

2TFTscreenFingerprintMachineconnectswithPCthroughnetwork
andHUBtocreatealocalnetwork

17

Installation

3)RJ45plugwiringdiagramsforEthernet
a)RJ45plugstandard

b)Ethernet10/100BaseTCrossoverCable
mostly apply to HUB and Switchor directly connect two Ethernet
terminals(notthroughHUB),fullysupport10BaseTand100BaseTX.
Plug1 Pin
Pin Plug2
TX+
1 <> 3
RX+
TX
2 <> 6
RX
RX+
3 <> 1
TX+
RX
6 <> 2
TX
18

Installationinstructionforiclockaccesscontrol V1.1.1

c)Ethernet10/100BaseTStraightThruCable
Support10BaseTand100BaseTX
applytoconnectwithnetworkcard
andHUBornetworkoutlet
sometimeitiscalled(whips)
Wiringstandard Pin
Color Pin Wiringstandard
TX+
1 < whiteorange >1
TX+
TX
2 < Orange
> 2
TX
RX+
3 < whitegreen > 3
RX+
4 < Blue
> 4
5 < Bluewhite > 5
RX
6 < Green
> 6
RX
7 < Whitebrown > 7
8 < Brown
> 8

3.2.6RS232connection
ThedefinitionofPCconnectionwithfingerprintmachine
PCSerialPort

Fingerprintmachineserialport(J12)

Pin2Rxd

Pin4Txd

Pin3Txd

Pin5Rxd

Pin5Gnd

Pin3Gnd

19

Installation

3.2.7RS485connection
RS485systemsusingabusstructureconfigurationconnectthedriverto
thereceiver. Thetransmissionlineismadebyagroupofpairtwisted
cable. Each transmitted signal has a pair of conductors consisting of
inverted and noninverted signal lines. The inverted line is generally
indicatedbytheindex"A"or"",withthenoninvertedlinedesignated
as"B"or"+".Thereceiversimplyevaluatesthedifferencebetweenthe
twolines,sothatcommonmodenoiseonthetransmissionlinewillnot
result in a falsifying of the actual signal, however, on the line may be
produced a difference mode disturbing. In order to eliminate this
disturbance,traditionalRS485networksrequirea12terminalresistor
tobeinstalledattheendofthebuscablesbasedonthephysicallayout
of the pairtwisted cables. In the normal condition the resistor is not
installed,onlyifthebusisextendedtoover100meters,thetermination
mustbeconnectedwithaterminalresistor.
20

Installationinstructionforiclockaccesscontrol V1.1.1

Thedefineofterminalconnection
Terminal(J12)

Function

Pin1485BWhite

RS485communication

Pin2485AGreen

RS485communication+

3.2.8 Wiegandoutputconnection
TFTscreenFingerprintMachineprovidesstandardWiegend26output,
which can be connected to most of access controllers, like the way of
connecting with a ID reader or password keyboard. The distance from
thecontrollertodevicecannotbemorethan15meter(ifthesignalmust
be transferred much further or there is a strong interference around,
pleaseadoptawiegandsignalamplifier)
Mote:no matterthe deviceis poweredbyaccesscontrolleror not,the
21

Installation

ground ports of them have to be properly together to ensure the


weigandtransferreliable
Terminal(J12)

Function

Pin6 GNDBlack

Ground

Pin7WD1White

Outputwieganddata1signal

Pin8 WD0Green

Outputwieganddata0signal

3.2.9 Connectwithexternal Weigendreader


AccesscontroldevicewhittheWeigandinputfunctionisabletoconnect
withcardreader,whichislocatedinoutdoororindoor,controlthedoor
bythecontrollertogether,thecablewhichbetweenaccesscontrollerand
externalcardreaderisnomorethan90meter.

22

Installationinstructionforiclockaccesscontrol V1.1.1

3.2.10Powerconnection
Thisdeviceispoweredby12VDC.Itscurrentisapproximately50mAin
the ready work status and 400mA in the work status. The power is
conducted along with the terminal you can use the 12V4A supply
adapter which is provided along with the device. The detail about
connectionisasfollow.
Terminal(J1)

Function

Pin1GNDBlack

Powernegative

Pin2PWRRed

Powerpositive

The following figure is an example which takes a provided power


adaptertoconnectto TFTscreenFingerprintMachine

23

Installation

Power

24

Installationinstructionforiclockaccesscontrol V1.1.1

3.3Fasteningfingerprintmachine
Confirmallconnectionplugscorrectly.
Alignbackironplateoffingerprintmachinebodytomountingplate
properly,andpushitup,thenpush devicebackward.
Turnandtieupthescrewbottom.
Afterfinishinginstallation,makeensurethebodyofdeviceisfixed
tightly.

25

Test andexamineafterinstallation

4.Testandexamineafterinstallation
Afterallsysteminstallation finished, makeatestand examine priorto
poweron,inspectwhetherthelockdriverisOKornot,formoredetails,
pleaseseeUserGuideandSoftwareManual
thegreenLEDbeginstoglitterafterpowerup.
entermenuOption Autotest.
entermenuUsermanageUserEnrollFingerprintEnrollEnroll
a fingerprint, and use the fingerprint to test access control system and
doorlock..
ifthereisnoanyproblem.Pleasedeletethisenrolledfingerprint.

26

Installationinstructionforiclockaccesscontrol V1.1.1

5.Others
5.1Reset
Duetooperationerrororotheraccidence,whichleadsthemachinenot
towork,youcanrestartmachinethroughresetkey.
takeasmalltoolwhichdiameterisnomorethan2mm.
find reset mark of reset on the left small hole on the bottom or
besideofdevice,seefollowingfigure.
Usethetoolplugintotheholerefertothepictureonright,thenplug
out.Themachineisabletorestart.

Reset

27

Others

5.2Antidismantlebutton
Antidismantlebuttonisonmiddleofdevice,whosefunctionisrealized
by backcover pressing the antidismantle button. When the device is
beingdismantled,itwillsendaalarmsignalthroughtheterminal,more
detailpleaseseethishandbook 3.2.3.

5.3UsingUflashdisk
thereisaminiportofUSB.
USB can be used to upload and download data by U disk, can be
connected with U.are.U fingerprint sensor as an external fingerprint
sensor.

USB

5.4BuiltinEMcardreader(Optional)
BuiltinacontactlessEMcardreader module,thedistanceofflashing
cardis510cm.itcompletelysupportsthethickcard(1.88mm),middle
card(1.05mm),andthincard(0.88mm),whoseoperatingfrequencyisat

28

Installationinstructionforiclockaccesscontrol V1.1.1

125KHZ.

5.5BuiltinMIFAREcardreader(Optional)
Contain a contactless MIFARE card reader module , the distance to
detect card is 510cm, it completely supports MIFARE cards that
provide operating frequency 13.56MHZ, communication speed
106KBPS.

5.6CabledoorbellOptional
Thereisakeywhichisremarkas icon

isusedfordoorbell.

onthekeypad,thiskey

Putthedoorbellintheproperplace,pressthedoorbellkeyonthedevice,
afterthedoorbellreceiveasignal,itwillring.
NoteBecausetheterminalandkeyourprovidedisusedforcable
doorbell,mustjointhepowerintotheelectricround.

29

Others

Power

DoorBell

30

Installationinstructionforiclockaccesscontrol V1.1.1

6.Troubleshooting
Trouble
PowerLEDisoff

Cause&Measure
Cause:Nopowerorlackofvoltage
Measure : Check and examine the
connection of PWR, GND, make sure they
contact well. Measure the supply voltage,
ensurethatitis12VDC.

Device is unable to Cause:Theconnectionproblem.


connectwithPC
Measure:Checkandexaminetheconnection
of RS232/RS485 or TCP/IP, whether its
connectioniscorrectornot.
After device power is
on, LCD display
always shows Please
tryagain.

Cause : For long time used, surface of


fingerprint sensor becomes dirty, or there
aresome scratchesonit,thedevicetakesit
as a fingerprint and does verification,
Fingerprint connection cable of fingerprint
sensorisloosed.Chiponboardisbroken.
Measure : Under such situation you can
use scotch tapetoadhibitthedirt.
Needtocontactsupplerandaskforrepair.

Startup bar cycles, Cause : Fingerprint connection cable of


andcantentermenu fingerprintsensorinsertimproperly
Fingerprintsensorbrokedown.
Chiponboardisbroken
31

TroubleShooting

Measure: PleasetakeouttheFingerprint
connection cable from slot of fingerprint
sensor,plugitagain.Itneedtocontact
supplertorepair.
The time display as Cause:Theclockbatteryisbrokedown.
00:00
after Measure: Contact the reseller to replace a
restarting
battery.
Thefingerprintsensor Cause: Fingerprint connection cable of
lightisoff
fingerprint sensor connection is broken.
fingerprintsensorbrokedown.
Measure: Please take out the FFC from
slot of fingerprint sensor, plug it again.
Contactsuppler,askforrepair.
keystroke and press Cause: Trouble in the buzzer, loud speaker
fingerwithoutsound orcircuit.
Measure: Need to replace the buzzer and
loudspeaker.
Some users finger Cause:Thefingerprintqualityispoor.
prints
sometimes Measure:Youdbetterselectfine fingerprint
cantbeverified.
(less crinkle, no desquamation, clear image)
when enroll fingerprint, make your finger
touch fingerprint sensor with larger area, a
comparable test should be made after
enrollment, we suggest you enroll more
fingerprints. By the way our device supports
1:1 match method and password identified
function,youcouldchooseoneofthem

32

Informationinthisdocumentissubjecttochangewithoutnotice
PrintedinChina

You might also like