You are on page 1of 1

R

Facia Windows & LED Annunciators

Phase Failure Relays (Multi Function)

Microfacia

P2 PFV1

ALV D2

Phase Failure
with UV / OV Relay

Phase Failure with UV / OV Relay

Microfacia
Microfacia are LED window
assemblies for RUN, TRIP or
FAULT indications. With
microfacia windows the
panel designers can improve
aesthetic value to the panel
indications in a R ow /
Column format. Microfacia is
useful for direct operation
with AC or DC voltage
Features
Fully Integrated
construction.
Suitable for Potential free
or Potential contact.
Common +ve or
Common -ve
Configuration.
Super Bright LEDs (RED
colour).
12 / 24 V DC models.
Low Power Consumption.
External Power supply for
110V, 220 V DC.
Front Replaceable
Windows & Inscriptions.
Two Window sizes - Big
& Small.
DIN standard panel
cutouts.
Molded Enclosures.

These are useful for monitoring


Mains Voltage Supply for general
voltage faults in AMF/Transfer
Switch Panels & Pump Control &
3 Ph Air conditioner control
Panels. VPG D1 is used for water
pumps to protect against phase
failure, phase sequence, phase
unbalance and dry running faults.
Supply Voltage
System
Auxiliary
Output Contacts
Trip Setting (Volts)
Phase Sequence
Phase Unbalance
Under Voltage
Over Voltage
Water Level
Trip Time Delay
On Phase Failure
On UV/OV
Resetting Mode
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)

110 / 240 / 380 / 415 / 440 V AC 20%


1 CO

240 / 380 / 415 / 440 V AC 20% 50 / 60 Hz


110 V (Fixed) or (220 - 230 - 240) or (380 - 415 - 440) V AC 20% selectable
1 CO (2 CO)
1 CO (2 CO)

Built-in
1 CO (2 CO)

Yes
40 V 6 V (fixed)
80% 5 V (fixed)
120% 5V (fixed)
N.A.

Yes
40 V 6 V (fixed)
80% to 95% (adjustable)
105% to 120% (adjustable)
N.A.

Yes
40 V 6 V (fixed)
85% to 95% (adjustable)
105% to 115% (adjustable)
N.A.

3.5 secs. 1.5 sec


Less than 2 secs.
Auto
400 gms.
76 x 56.5 x 117.5
67 x 46

380 / 415 V AC 15%, 50/60 Hz

Yes
40 V 6 V (fixed)
80% to 95% (adjustable)
105% to 120% (adjustable)
N.A.

3.5 secs. 1.5 sec


Manual / Remote
430 gms.

3.5 secs. 1.5 sec


Less than 2 secs.
Auto
400 gms.

3.5 secs. 1.5 sec


Less than 2 secs.
Auto
250 gms.

76 x 56.5 x 117.5
67 x 46

76x 56.5 x 117.5


67 x 46

80 x 35 x 95
11 - Pin Plug-in

Less than 2 secs. for OV & 2 - 5 secs for UV

Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)


* CE marked products available on request.
OV

Aux
Supply

RYB

13

15

3 Ph
13

14

13

16

15 16

Td : 2-5 Sec.

11

Unbal./
Phase Fail

Td : 2-5 Sec.

17

18

L1

L2

L3
B

MOTOR

R
MOTOR

L1

L2
Y

L3

MOTOR

N/V
N/V

OFF

ON

OFF

ON

P2 PFV1

DOL STARTER

DOL STARTER

NC
1

NO

5
1 2 3 4 5 6

AUX.
SUPPLY
7 8 9 10 11 12

4
3
2

1 2 3 4 5 6

HLS D2

Ordering Information

RYB

F3 ADA1

RYB

RYB R B

Td : 2-5 Sec.

14

R B
Unbal./
Phase Fail

3 Ph

R Y B

R B

Unbal./
Phase Fail

13

UV
Built in
Aux Supply

UV
R Y B

3 Ph

OV

OV

UV
Aux
Supply

11

Available in DIN Rail mounting, 8


or 11 pin Plug in type socket
mounted, 96 x 96-panel door
mounted enclosures.
Features:
Relays monitor 3 Phase
Voltage Supply.
Models with multi functions
like Phase loss & Dry Run,
Phase Loss with UV or
UV+OV etc
Models with Adjustable trip
level settings.
Monitors Aux. Voltage for
Under & Over Voltage.
Powered by External or Built in
Aux. Supply.
Auto Reset, Manual / Remote
Reset
1 or 2 CO outputs
DIN Rail or Plug in socket
mounted or Panel Flush
Mounted enclosures

ALV D2
HLV D2

HLS D2

AUX.
SUPPLY

13 14 1516 17 18

7 8 9 10 11 12

Product Family Name

ALV D2
HLV D2

11

6 7

Monitors the input potential


free contacts (NO or NC) for
any change of status
(Abnormal) & activates one
common output relay for
audible device with
respective flashing LED
windows. Thus indicating the
'Alarm' status. This flashing
annunciation window is
'Acknowledged' & 'Reset'
(when retur ns back to
normal) by external push
button.
Features :
Suitable for 4 alarm
points.
Optically isolated Inputs.

MF951

MF955

PARAMETERS
Auxiliary Supply *

12 / 24 / 110 / 220 V AC / DC

24 V DC, 110 / 220 V AC / DC

Input

Potential Free Contacts or Potential Contact

Potential Free Contacts (NO or NC Site configurable)

Output

Window Facia LEDs on front

1 NO for Audible Hooter

Rating

5 A, 230 V AC Resistive

Facia Window Sizes

Big : 66 x 30 mm

Flash Rate

Small : 30 x 30 mm

LED

Colour RED (Amber / Green on request)

Colour RED (Amber / Green on request)

Interrogation Voltage

+ 12 V DC

Response Time

25 msec. 10 msec.

Power Consumption

1.5 Watts per Window

1.5 Watts per Window

Grouping (Trip / Non Trip)

Optional

Optional

Dimensions (mm)

Overall (L x W x D ) (w/o PSU 144 x 72 x 80)

Overall 96 x 96 x 140

72 x 144

Window Dimensions for Small 30 x 30, for Big 62 x 30

Cutout 92 x 92

66 x 138

Unit Dimensions : (With PSU) 144 x 72 x 215


Weight (Approx.)

700 gms. (With PSU)

1200 gms.

250 gms. (W/o PSU)


Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)
* Applicable only for Microfacia with potential free inputs.

F8
F7
C
F6
F5
C
F4
F3
C
F2
F1
C
-VE
Aux. Supply
+VE

W8

Typical Connection Diagram

W7

A
A
A
A
A
A
A
A

W6
W5

W4
W3

W2
W1

W8

Ext. Fault Inputs

W7

NO

W6
W5
W4
W3
W2
W1

Ext. Push
Button Inputs

T
M
A
R
C
D

G1

NC
G2

ON

D
I
P

F1
F2
F3
F4
S1
S2
S3
S4

OFF

+VE

Aux. Supply

VE

F1
F2
F3
F4
I1
C1
I2
C2

HOOTER
N

Rear view
Panel Cutout Details

66

96

68

96

10

11

NC
11

144

96

92

138
System Watchdog

Bottom view

F3 ADA1

Auxiliary Supply Voltage

27

92

Alarm Annunciator

Front View

Panel

F8
F7
F6
F5
F4
F3
F2
F1
-ve

TERMINAL STRIP

Unit

3 Phase System Voltage

Applications
Battery charger Panels
Generator Control Panels
Machine Control Panels
Package AC Units etc.

These are LED Facia windows with


Potential input or potential free input.
Microfacia is available in either 4 Big or
8 Small windows size. Standard
models available for 12V/24V DC and
110V/230V AC. Mounting dimensions
are as follows

13 14 1516 17 18

Model Name

N.A. (LED Indicators are provided)


Fast - 60 flashes/min. Slow - 30 flashes/min.

NO
1

F3 ADA1

FLT/GRP

Phase Failure
with UV / OV Relay

SELECTION

HLV D2

Phase Failure
with UV / OV Relay

SEQUENCE

HLS D2

10

132
142

Overall Dimensions

Panel Cutout

You might also like