Features:
1. Counting speed is up to 10KCPS;
For your safty, please read following content carefully before you are using our Meter!
www.alltronicsperu.com
S
KKCIE01-A/1-1
1. Model Illustration
CI-R
C 0
0: Without Communication
8: With Communication
F: 24VDC
2. Model Type
No.
Model
Size (mm)
Output
CI16-RC60
80H160W
Relay Output
CI16-RC68
80H160W
Relay Output
CI8-RC60
48H96W
Relay Output
6
6
CI8-RC68
48H96W
Relay Output
One Relay
CI7-RC60
Relay Output
One Relay
CI7-RC68
Relay Output
One Relay
CI4-RC60
Relay Output
NO
Display Digit
6
Relay Output
CI4-RC68
Alarm Output
2
Batching Output
One Relay
One Relay
One Relay
NO
Communication
NO
RS485
NO
RS485
NO
RS485
NO
RS485
3. Technical Specification
Series
CI
Display
Power Supply
100-240V AC/DC
www.alltronicsperu.com
Fluctuation range of Allowed Voltage
Input
Counter
One-shot Output
Timer
Contact Capacity
Control Output
SSR Capacity
10/50/100/200/500/1000/2000/5000ms
10/50/100/200/500/1000/2000/5000ms
NO:250VAC 3A Impedance
Ten Years
12VDC10%
Ambient Temperature
-1050
Unfreezing State
Storage Temperature
Ambient Humidity
35-85%RH
Time Accuracy
Dielectric Strength
Mechnical
Vibrate
Fault
Mechnical
Impact
Using Life
Dielectric
Interferance (AC Power)
Fault
NC250VAC 2A Impedance
2kV
Power On 0.05%0.05sec
With Signal 0.05%0.03sec
(at500VDC)
50/60Hz one minute
Amplitude:0.75mm
Amplitude:0.5mm
Mechnical
Electrical
KKCIE01-A/1-2
4. Panel Indication
Lock: Button lock indication (CI16, CI8 do not with this lamp)
OUT1, OUT2: OUT1 or OUT2 output indication
BA.O: Batch output indication (CI3, CI4 do not with this lamp)
CNT: In the counting status
TMR: In the timing status
PS1
PS2
BA.S
Reset Key
LOCK
OUT1
RST
BA
OUT2
BA.0
CNT
TMR
MD
5. Operation Instruction
1. How to change counter setting value (Example: change the setting calue from 175 to 180)
1
2
PS1
PS2
BA.S
LOCK
OUT1
RST
BA
OUT2
BA.0
CNT
TMR
PS2
MD
Press
key or
key 5 times,
change the digit 5 to 0.
PS1
BA.S
LOCK
OUT1
OUT2
RST
BA
MD
BA.0
CNT
TMR
key to display setting value change status, the flickering digit is from right to left circularly.
www.alltronicsperu.com
Press
key to choose digit 7
and let it flicker.
PS2
PS1
PS2
BA.S
BA.S
LOCK
OUT1
OUT2
RST
BA
MD
BA.0
CNT
PS1
PS2
BA.S
TMR
LOCK
OUT1
RST
BA
OUT2
BA.0
CNT
TMR
Press
key once to change digit 7
to 8, press
key to confirm the
change and return to measuring status.
MD
MD
t.ON
MD
In setting status, the menu will return to timing status automatically if no operation within 60 seconds.
How to change t.OFF time to 50sec from 30sec change t.ON time to 20sec from 40sec (output mode: FLK timing range: 0.1s to 99999.9s).
Press
key twice to change digit 3
to 5, press
key to confirm the
change and display t.ON setting status.
key to display setting value change status, the flickering digit is from right to left circularly.
Press
key to choose digit 4
and let it flicker.
Press
key twice to change digit 4
to 2, press
key to confirm the
change and return to timing status.
KKCIE01-A/1-3
Batch counting
Batch counting value counts up, it will not be reset unless external BATCH reset signal is applied.
When batch counting value counts over 999999, it will be reset to 0 and counts again.
Batch couting value is not reset by front
key or external reset signal.
(1) Batch counting in Counting mode.
Batch alarm outputs when counting alarm output quantity is equal to the batch setting value.
When batch control output is used, the time interval of counting up process is bigger than 10mS.
(2) Batch counting in Timing mode.
Batch alarm outputs when timing alarm output quantity is equal to the batch setting value.
In FLK output mode, the counting value of Batch counter is counting up, when Toff and Ton setting time passes.
Batch output action
If batch output is ON, it will keep ON status until batch reset signal is applied.
If batch output is ON, after power off and then power on again, batch output keeps ON status until external reset signal is applied.
2. How to change batch setting value
BA key
Measuring status
MD key
Batch setting value change status
www.alltronicsperu.com
After changing the value, the upper LED will display the current batch counting value.
When batch setting value is bigger than batch counting value, if the setting value is changed (equal or smaller
than the counting value, the batch output takes action.
If batch setting value is 0, the batch output is in OFF state.
When menu is batch setting value change status, if no button operation within 60 second, the menu will return to measuring status.
KKCIE01-A/1-4
Setting Mode
Input Type
If the output Mode is S, T and D, then input mode just can choose Ud-A, B, C
MD
Counting Speed means the highest frequency of INA and INB allowed input, if
the setting value is 5K, the error will be existed if the input signal over than 5K.
Up Or Down Input Mode
Output Mode
Up/Down - ABC Input Mode
MD
MD
MD
OUT2 Output
Time
OUT1 Output
Time
Units: ms
Units: ms
Input Logic
www.alltronicsperu.com
MD
1 20
or
MD
- - - - - -
Decimal Point
- - - - - *
- - - - - *
- - - - - *
Memory Retention
MD
MD
Prescale Value
MD
Baud Rate
(
MD
MD
Address
MD
Lock Key
MD
Counter/ Timer
: Couner
Timer
1. If you choose F or N output mode,, when the counting value reached setting value,the output
will be keeped, there is no OUT2 output time menu in function setting mode.
2. If the output Mode is S, T and D, then input mode just can choose Ud-A, B, C. If the input mode want to choose UP/DOWN,
then output mode just can chosoe other modes except S,T,D.
3. If the output mode choose D, when counting frequency over than 1Kcps, please choose SSR output.
4. When the Max counting speed is 5Kcps or 10Kcps, if change output mode to D, counting speed will automatically choose 1Kcps.
5. In the mode of function setting,the external input signal can be accepted, after exit, display value and output will be reset automatically.
KKCIE01-A/1-5
Setting
Time Range
MD
U
Up
Up/Down Mode
MD
Output Mode
MD
Output Time
Unit: ms
Output delay time choose
MD
Input Logic
and
: Input mode choose
Voltage Input
No voltage input
MD
Unit:ms)
Baud Rate
(
MD
Address
www.alltronicsperu.com
(
MD
MD
Lock key
MD
Counter
Timer
Counter/Timer
11.Timing Range
Function Setting
11.Timing Range
Display
0.01s9999.99s
SEC
0.1s99999.9s
SEC
1s999999s
SEC
0.01s99m59.99s
0.1s999m59.9s
Range Display
0.1m99999.9m
1m999999m
1s99h59m59s
1m9999h59m
H S
H
KKCIE01-A/1-6
Note
Illustration
No Counting
Counting Value
U
Add
No Counting
Counting Value
Counting Value
No Counting
Counting Value
D
Minus
No Counting
Counting Value
Counting Value
www.alltronicsperu.com
Ud-a
Add/ Minus-A
Order Input
Ud-b
Add/Minus-B
Sole Input
Counting Value
Ud-c
Phase Difference Input
Counting Value
Counting Value
When using rotary encoders A, B ohase output, please connect meters INA, INB input terminal, and turn the input mode to Ud-C.
Input Type
Symbol
5-30VDC
Short Circuit
0-2VDC
Open Circuit
KKCIE01-A/1-7
One-shot Output
OUT2 Output
Hold Output
Input Mode
Up
Down
Simultaneous Output
Up/DownA,B,C
Reset
999999
SV2
Display
SV1
0
OUT1
Output
OUT2
Output
Reset
999999
SV2
Display
SV1
0
OUT1
Output
OUT2
Output
Reset
999999
SV2
Display
SV1
0
OUT1
Output
OUT2
Output
Reset
999999
SV2
Display
SV1
www.alltronicsperu.com
0
OUT1
Output
OUT2
Output
Reset
999999
SV2
Display
SV1
0
OUT1
Output
OUT2
Output
Reset
999999
Display
SV2
SV1
0
OUT1
Output
OUT2
Output
Reset
999999
SV2
Display
SV1
0
OUT1
Output
OUT2
Output
Reset
999999
SV2
Display
SV1
0
OUT1
Output
OUT2
Output
KKCIE01-A/1-8
Up/DownA,B,C
Operation
OUT1 and OUT2 meet following
conditions,will keep ON status:
Display ValueSetting Value 1
Display ValueSetting Value 2
SV2
SV1
SV2
SV1
SV2
SV1
Time Range
MD
MD
www.alltronicsperu.com
MAX counting speed (CPS)
MD
MD
MD
MD
MD
MD
MD
MD
Counting
Mode
Timing
Mode
MD
Decimal Point (dP)
MD
MD
Prescale Value (SCL)
MD
Counting Value Save (DATA)
MD
Baud Rate (BAUD)
MD
Address (ADD)
MD
Lock key (LOCK)
MD
Counter / Timer (C-T)
Under the mode of Counting can directly change to Timing mode;
.In the mode of function setting, counter will return to the measuring status automatically after
KKCIE01-A/1-9
One-shot Output
Hold Output
t=One-short output time
Output Mode
Activation
1. Timer starts when INA signal turns ON;
when INA signal turns OFF, time reset.
2. Timer starts when power turns ON and
when reset turns OFF during INA signal ON.
3. Control output operate decide by hold or
One-short time.
Power
(OND)
INHIBIT
RESET
OUT-2 (Output)
up
UP (Setting Time)
Display
0
Down Down (Setting Time)
0
INA
OUT2
(Output)
Power
INA
INHIBIT
RESET
OUT-2 (Output)
UP (Setting Time)
up
0
Display
Down Down (Setting Time)
0
OUT2
(Output)
Power
INA
(OND.2)
Power
INA
INHIBIT
RESET
T:preset time
(OND.1)
Hold Output
T:preset time
HOLD
Power
OUT-2 (Output)
UP (Setting Time)
up
0
Display
Down Down (Setting Time)
0
www.alltronicsperu.com
OUT2 T:preset time
(Output)
Power
INA
(FLK)
INHIBIT
RESET
Power
INA
OUT-2 (Output)
UP (Setting Time)
up
0
Display
Down Down (Setting Time)
OUT2
(Output)
OUT2
(Output)
Power
INA
OUT-2 (Output)
UP (Setting Time)
up
0
Display
Down Down (Setting Time)
(FLK.1)
T: Setting Time
Power
INA
OUT2
(Output)
KKCIE01-A/1-10
(INT)
HOLD
T: Time setting
(FLK)
T- C
OUT2
(Output)
Power
INA
INHIBIT
RESET
OUT-2 (Output)
UP (Setting Time)
up
0
Display
DownDown (Setting Time)
0
Power
INA
OUT2
(Output)
T: Time setting
www.alltronicsperu.com
INTERVAL 1 (POWER OFF RESET)
(OFD)
OUT2
(Output)
T: Time setting
Power
INA
INHIBIT
RESET
OUT-2 (Output)
UP (Setting Time)
up
0
Display
DownDown (Setting Time)
0
Power
INA
T
OUT2
(Output)
T: Time setting
15.Connection Drawing
CI4
CI7
20 19 18 17 16 15 14 13 12 11
1
CI8
AL1
AL2
10
BATCH
POWER
AC/DC
100-240V
I NB
BBATCH
A T C H INHIBIT
I N H IBI T R E S E T G N D +12V INB
R ESE T
RESET
1
IINA
NA
10
POWER
CI16
AL2
11
12
AL1
13
14
BATCH
R E SE
RE
SET
ATCH
BBATCH
15
IINN HI
H I B IT
IT
1 0 0 2 4 0 V A C
16
17
18
19
20
RESET
GND
+12V
IINB
NB
IINN A
Note: If there is any change, please subject to the drawing on the meter!
KKCIE01-A/1-11
Timer/Counter
+12V
5.4k
+12V
5.4k
Inner Circuit
Inner Circuit
GND
GND
Timer/Counter
+12V
+12V
Inner Circuit
Inner Circuit
5.4k
5.4k
GND
GND
SSR Output
Timer/Counter
Load
(+)
SSR Output:
1. Please use adaptable load and power, SSR output
can not over then ON/OFF, capacity (30VDC, less than100mA)
2. Making sure that the power connected in the right way,
3. When using Inductive load(Relay, etc), Filter circuit(Diode, etc)
must connect to the load ends
www.alltronicsperu.com
Load Power
(-)
Load
Power
(DC)
Load
18. Dimension
Side Face Size
Panel Size
A
Mounting Size
G +0.5
-0
C
E
J +0.5
-0
B
Model
H(Min)
K(Min)
CI4:(48*48)
48
48
97.5
94.5
45
45.5
25
45.5
25
CI7:(72*72)
72
72
97.5
94.5
67
67.5
25
67.5
25
CI8:(48*96)
96
48
97.5
94.5
44.5
90
25
45
25
30
155.5
30
CI16:(160*80)
160
80
96
13
83
155
76
www.alltronicsperu.com