Generator Model:
Engine Model:
Alternator:
TC1650
Cummins KTA50-G9
Stamford PI734B
Three Phase
Power Factor:
Cos = 0.8
Prime Power
PRP
kW
kVA
1200
1500
Standby Power
LTP
kVA
kW
1650
1320
60Hz
1800 r.p.m
Rating
Voltage (V)
480/277
Scope of Supply:
High efficient water cooled diesel engine
Brushless alternators (Class H, with AVR.)
Heavy duty rubber anti-vibration mountings
24V starter batteries and connecting cables
Engine-drive battery charging alternator
Container type generator sets
Auto start Digital Control Panel
Radiator with cap and drain point
Fully guarded engine driven fan
Circuit Breaker
Fuel tank for 6-8 hours running
Operation & Maintenance Manual & Diagrams
Factory Testing Report
Emissions Certification:
Rated Current
(Amp)
1804,27
We reserves the right to change the specifications
without notice and without any obligation or liability
whatsoever.
Warranty:
The goods manufactured Tang Power are under
warranty against defects in materials and workmanship
for a period of 12 months or 1000 hours whichever
come first from the date of delivery to the end user
(except the damageable spare parts of genset caused by
incorrect man-made operation), and that the
aforementioned warranty for the same token is back up
by the engine & alternator manufactures and their
global distributors.
Silent Type Genset: 12000*2400*2400mm/10000kg
Dimension need to be confirmed before
shipment,canopy design are subject to change
without notice.
Generator Specification
(Diesel - 480V Available)
Generator Model:
TC1650
Engine Model:
Cummins KTA50-G9
Alternator:
Stamford PI734B
(1) Engine Specification
General Performance
Manufacture
CCEC Cummins
Engine Model
Engine Type
Engine Speed
Base Output Power
Standby Power
Governor Type
KTA50-G9
4 Cycle, 60 Vee, 16 Cylinder
1800 r.p.m
1384kW/1855hp
1656kW/2220hp
Electronic
Compression Ratio
13.9:1
Thermal
725-775 r/min
9.5 m/s
2075 Litres/sec.
Cooling System
140 Litres
82 - 93
104
100
Electric System
24V
Maintenance-free
Auailable
170-200kkW
620-715kW
910-1040kW
Generator Specification
(Diesel - 480V Available)
Generator Model:
Engine Model:
Alternator:
Exhaust System
TC1650
Cummins KTA50-G9
Stamford PI734B
5025 Litres/sec.
470 - 515
51mm Hg
Manufacture / Brand:
STAMFORD
635mm H2O
381mm H2O
Model
AVR Model
Winding Leads
Phase
Power Factor
PI734B
MX321
6
3 Phase
Cos = 0.8
178-148 Litres
2/3 - (N 6)
IP 23
121
N/A
Fuel System
1352kW/1690kVA
1448kW/1810kVA
H
0,5 %
<3,5%
< 50
<2%
1000 m
N/A
Lubrication System
Type Of Injection:
Fuel consumption:
1- At 100% Standby power
2- At 100% Prime power
3- At 75% Prime power
4- At 50% Prime power
Fuel Tank Capacity:
(A) Informations:
Prime Power:
Available continuously at variable load
in lieu of commercially purchased
power for an unlimited number of
hours per year in accordance with
ISO8528-1, and an overload of 10%
permitted for one hour in every
twelve hours of operation in
accordance with ISO 3046-1.
(B) Informations:
Standby Power:
Emergency Standby Power in variable
load applications in accordance with
ISO8528-1 in the event of a utility
power failure. No overload available
for this service as relevant alternators
are peak continuous rated at 27.
Generator Specification
(Diesel - 480V Available)
Generator Model:
Engine Model:
Alternator:
TC1650
Cummins KTA50-G9
Stamford PI734B
Control Systems
Synchronising Panel:
ModelComAp IC-NT MINT
* Compact gen-set controller for gensets operating
in multiple island and/or parallel to mains mode
(together with MainsCompact NT)
*Cooperation of up to 32 gen-sets
* Simple paralleling (easy wiring, installation and
configuration
Key features:
*Generator measurements: V, A, kW, kVAr (3
phase, true RMS), Hz, including energy counters
*Bus measurements: V (3 phase, true RMS), Hz
*Generator and Engine protections (incl. Vector
Shift)
*Automatic synchronizing and load control (via
speed governor or ECU)
*AVR control (Volt and PF control)
*Digital active and reactive load sharing
*Advanced power management function
o Load Dependent Start/Stop
o Load Demand Swap
o Running Hours Equalization
*Wide range of communication interfaces RS232,
RS485, USB, Modbus, GSM/Analog modem,
GPRS, Ethernet
*Support of electronic controlled engines (J1939,
Modbus)
*Event based history with capacity for nearby 200
records.
Generator Specification
(Diesel - 480V Available)
Generator Model:
Engine Model:
Alternator:
TC1650
Cummins KTA50-G9
Stamford PI734B
Body made from 2.0mm sheet steel components with powder coating
Base Frame & 4-12 hours built-in fuel tank integrated into the skid-mount base (TBC)
Excellent design and craftmanship
Zinc alloy with black powder coated or Bright polished stainless steel hinges tested
and proven to withstand corrosive conditions.
Compact structure and longer service life
Generator Specification
(Diesel - 480V Available)
Generator Model:
Engine Model:
Alternator:
TC1650
Cummins KTA50-G9
Stamford PI734B
Transportability
Transportability
Noice Level:
73-80dBA at 1m & 65-72dBA at 7m (Small capacity genset)
77-88dBA at 1m & 67-78dBA at 7m (Middle and big capacity genset)
Noice Level:
85-88dBA at 1m