Professional Documents
Culture Documents
CDAX605
High
Automatic
measurement process
Measures
High
Works
All
Description
CDAX 605 is a capacitance and dissipation factor test set to be used
with an external power source/generator. It is a precision instrument
using a combination of bridge and direct (vector) measurements
and is capable of measuring capacitive, resistive and inductive loads.
CDAX605 together with a high voltage AC source and a standard capacitor forms a complete setup for insulation testing.
CDAX605
High-precision capacitance and dissipation factor measurement instrument
Application
Application areas
Power
Transformers
Instrument
Transformers
Power
Shunt
Reactors
Capacitors
Liquid
or Solid Insulations
Bushings
Inaccuracy
Wide
0-360
phase measurements
Reference
Works
Test
UST-R,
Low
Easy
LabView
CDAXControl
CDAX605
High-precision capacitance and dissipation factor measurement instrument
Specifications CDAX605
Environmental
Application field
Ambient temperature
Operating
Storage
Humidity
The instrument is intended for use in highvoltage test rooms and laboratories as well
as in substations and industrial environments.
-20C to +55C (-4F to +131F)
-40C to 70C (-40F to +158F)
< 90%RH, non-condensing
Dissipation factor
Phase
Calibration
CE-marking
LVD
EMC
2004/108/EC
2006/95/EC
General
Mains voltage
Power consumption
Dimensions
Instrument
Transport case
Weight
Max resolution
Capacitance
Dissipation factor
Phase
Measurement time
Warm-up time
* The values for inaccuracy values are valid at test frequency 50/60 Hz, over full operating
temperature range after warm up and self-calibration. THD of power source <10%.
Reference input current <300 mA and reference to measurement current ratio <100:1.
Software
CDAX605 Control
PC requirements
Measurement
Channels
Inputs
Measurement range
Test frequency
Test voltage
Capacitance
Dissipation factor
Current
Phase
Inaccuracy*
Capacitance
Voltage/current
SWEDEN
Megger Sweden AB
Eldarvgen 4, Box 2970
SE-187 29 TBY
T +46 8 510 195 00
F +46 8 510 195 95
E seinfo@megger.com
2
4 connectors, Cn, Cx1, Cx2 and Ground
BNC and UHF connectors
5 400 Hz
Unlimited (pending reference capacitor or
resistor value only)
0-100 F
0100
0-5 A (Can be increased by using input
transformer)
0-360
0.02% at 30 A to 300 mA measurement current
0.1% at 300 mA to 5 A measurement
current
0.5% of reading
UK
Archcliffe Road Dover
CT17 9EN England
T +44 (0) 1304 502101
F +44 (0) 1304 207342
Ordering information
Item
Art. No.
CDAX605
AI-19090
Included accessories
Mains cable
Ground cable
Ethernet cable
CDAXControl (PC SW)
Transport case
Users Manual
Optional accessories
5 A measuring cables
6 m (20 ft) with one UHF connector and one open end GC-30410
5 A measuring cables
18 m (60 ft) with one UHF connector and one open end GC-30420
Other cables/connector configurations on request
CDB605
Demo box for CDAX
AI-90010
CRD605
High voltage resistor, 2 kV/20 M
AI-90020
CDAX605 _DS_en_V02
www.megger.com
Megger is a registered trademark